1. SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947_ 110523 Page 10 of 14 CALIBRATION IMPORTANT CALIBRATION CHECK Qualified service personnel only should perform this procedure Load cells have no user serviceable components and should not be tampered with for any reason Re calibration is generally not required but should be verified periodically to ensure accuracy The recommendation for calibration check is at least once every 12 months or as individual maintenance policy requires SR a3 by SR instrument Inc Maximum Capacity 400 Ib x 2 Ib Figure 4 Button Display NOTE Ensure that nothing is in contact with the scale system during this procedure and that all six 6 feet are touching a level surface Remove hands from the system when noting the displayed calibration results Use a known calibrated weight traceable to NIST STEP 1 Press the ON ZERO button to turn the scale on STEP 2 Press Lb Kg button and toggle to select Ib STEP 3 Press and hold the WEIGH button until UNIT is displayed STEP 4 Toggle the HOLD RECALL button to read CAL then press WEIGH STEP 5 DISPLAY will read FULL or 1 4 Use HOLD RECALL button to toggle to the weight your
2. handles on the underside of the scale for easy portability SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947_110523 Page 7 of 14 SPECIFICATIONS MAXIMUM WEIGHT CAPACITY PLATFORM SIZE DISPLAY TYPE DISPLAY RESOLUTION ACCURACY AUTO ZERO AUTO POWER DOWN AVERAGING POWER SUPPLY CALIBRATION OPERATING CONDITIONS TRANSPORT and STORAGE 400 Ib 182 kg 24 in x 48 in x 2 in 61 cm x 122 cm x 5 cm 1 0 LCD display with 5 active digits 0 2 Ib 0 1 kg 0 2 2 digits of displayed resolution for calibrated range One button operation Approximately 120 seconds Automatic digital filter Six 6 AA 1 5 volt alkaline batteries Calibration 1s traceable to NIST standards Normal operating conditions for this product Ambient Temperature Range 68 F to 85 F 20 C to 30 C Relative Humidity Range 0 85 Avoid exposure to high pressure water or steam Storage and transport conditions should not vary outside the following conditions Relative Humidity 096 to 85 Ambient Temperature 14 F to122 F 10 C to 50 C Remove batteries if storing longer than three 3 months SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 58
3. using Refer to chart below l4 for 100 Ib weight V for 200 Ib weight FULL for 400 Ib weight Once correct weight is selected press WEIGH button display will read 0 0 LB STEP 6 Load selected applied weight Scale will read a span count wait for it to stabilize Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947 110523 Page 11 of 14 CALIBRATION cont d STEP 7 Press WEIGH button SAVE will appear on the display then display will read the selected applied weight 100 0 Ib 200 0 Ib or 400 Ib STEP 8 Remove the weight and the display will read 0 0 LB STEP 9 Calibration is completed turn scale off CAUTION The integrated circuits and semiconductors on the printed circuit boards may be damaged by electrostatic discharge ESD Be sure to use proper handling precautions at all times TROUBLESHOOTING SYMPTOM REASON CORRECTIVE ACTION Display reads LOW Battery needs to be replaced Display reads LOW Ensure scale is on a level surface Check to make sure all six feet are touching ground and ensure that nothing is touching bottom or sides of platform For additional information or assistance phone our Service Hotline 1 800 654 6360 or e m
4. 54 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947_ 110523 Page 8 of 14 Maximum Capacity 400 Ib x 2 Ib ON ZERO WEIGH BUTTON FUNCTIONS SR n es 8 by SR Instruments Inc CARR B Figure 3 Button Display The ON ZERO button is used to zero the system before placing a patient onto the scale system Ensure that nothing is in contact with the weighing surface during this procedure The display will read 0 0 LB or KG The WEIGH button wakes up the display and shows the patient s weight if it should Auto Power Down before the weighing process is done HOLD RECALL LB KG The HOLD RECALL button freezes the displayed weight and stores it away in memory Press HOLD RECALTL to store the weight into memory To recall last weight reading press HOLD RECALL If you press the HOLD RECALL button before placing patient on scale the scale will automatically lock the display once weight is stable Weight data may be viewed in either pounds or kilograms Pressing the LB KG button allows the operator to toggle between the two readings Both pounds and kilograms are displayed in a resolution of 0 1 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstrum
5. 9 9 8 0 103 195 E LO Porn n 10 9785 15329 E E CEU COIN odi Dr M 11 TROUBLESHOOTING 2 terie eno PeEEEDEEREEE EE 11 WARRANTY frc 12 LO MU E 13 TABLE OF FIGURES Frowre T Assembled SR Y 947 ecreis iti cem eversa dediei dene da coe ceri et Nd a a Erenn 4 Figure 2 Battery ComparUnelE cicceccssiccveseteccudseecveveccctccustaccvavesstecsulssesvevscestccusseeccevsustecculsseccessacoese 4 Pureo Bulton WISI IAY soner rsr neptis iain etii EEEE E T 8 TOUTS sa Dutton pir 10 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947_110523 Page 3 of 14 PACKING CHECKLIST Model SRV947 Portable Platform Scale DESCRIPTION QUANTITY CALIBRATION CERTIFICATE lea WARRANTY CARD ea MANUAL ea SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947_ 110523 Page 4 of 14 ASSEMBLY Figure 1 Assembled SRV947 To install included six 6 AA 1 5 volt alkaline batteries
6. Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947_110523 Page 1 of 14 SRScalegs by SR Instruments Inc Model SRV947 Portable Platform Scale Operating and Service Manual Serial Numbers 1000 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947 110523 Page 2 of 14 TABLE OF CONTENTS TABELE OF FIGURES i een EUR PI ie ue Eva Dr e IIT Nee 2 PACKING CHECKLIST MODEL SRV947 scscsssivsscecscstacscsevencecsessanscsivsavevseetenectesenvecsevsasecsiesucise 3 NUI T 4 SYSTEM DESCRIPTION AND INTENDED USE cccccccccecccccccccccccccscccscccssccsccceesees 5 NLAINTEINAINEB IN CLEANING s inito QI ee E EHIEEREREEEL NIA PNE ENNEN UIEE REL IGI ERARE e RUE 6 STORAGE AND TRANSPORTATION iscssscsccscucesvessstexscasesestensancaceacadesvessstexscasevestensentacescusescessess 6 SPECIEI ATION accidit rsd hace henctateiccuesesncnctdie A E msistacebenciatersiensesecastaiensistassiecses 7 BE EO 2 ME IO ORE LE o op p 8 BASICSYSTEM OPERA TION uo riter inii eda Evs ea ENSE eo Ee L eoo vEUES FERE NOv e Dn IRE Ero DeL evo ESOS FIRE 9 BAITERY REPEACENIEN D conii
7. SR Instruments Inc e Noreturns accepted after 60 days SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947 110523 Page 13 of 14 NOTES SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947_110523 Page 14 of 14 SRScaleg By SR Instruments Inc Precision amp Technology in Perfect Balance SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc
8. ail sri srinstruments com SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947 110523 Page 12 of 14 WARRANTY TWO 2 YEAR LIMITED WARRANTY Each SRScalles system is manufactured with high quality components SR Instruments Inc warrants that all new equipment will be free from defects 1n material or workmanship under normal use and service for a period of two 2 years from the date of purchase by the original purchaser Normal wear and tear injury by natural forces user neglect and purposeful destruction are not covered by this warranty Warranty service must be performed by the factory or an authorized repair station Service provided on equipment returned to the factory or authorized repair station includes labor to replace defective parts Goods returned must be shipped with transportation and or broker charges prepaid SR Instruments Inc s obligation is limited to replacement of parts that have been so returned and are disclosed to SR Instruments Inc s satisfaction to be defective The provisions of this warranty clause are in lieu of all other warranties expressed or implied and of all other obligations or liabilities on SR Instruments Inc s part and it neither assumes nor authorizes an
9. ents com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947_ 110523 Page 9 of 14 BASIC SYSTEM OPERATION SETTING SYSTEM ZERO Make sure the scale is free and clear of any obstructions and press the ON ZERO button to zero the system In a few seconds the display will read 0 0 LB or KG Note If patient will be using anything additional for support on the scale place this item on the scale while zeroing the system This will ensure that the patient s NET weight will be displayed It is recommended that the system be zeroed prior to each new patient After the scale has been set to zero position the patient on the scale Display will indicate the patient s weight in either pounds or kilograms WEIGH WEIGH In this default mode the weighing surface remains active Press the WEIGH button once to wake display and take reading HOLD RECALL If you press the HOLD RECALL button before placing patient on scale the scale will automatically lock the display once weight is stable To return to WEIGH mode when finished press the WEIGH button once The display will become active BATTERY REPLACEMENT The Portable Platform Scale contains six 6 AA alkaline 1 5 volt batteries The low battery indicator is displayed when the battery power 1s insufficient to power the scale Refer to Assembly Instructions Figure 2
10. exceeding 400 pounds or 182 kilograms gross weight Please read the following warnings to avoid injury to the animal or attendant WARNING DO NOT USE FOR ANIMAL TRANSPORT DO NOT EXCEED MAXIMUM LIMIT OF 400 LBS 182 KG SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947_110523 Page 6 of 14 MAINTENANCE and CLEANING The SRV947 Portable Platform Scale is made with a powder coated aluminum platform Exercise caution when cleaning the display window as it is made of a clear plastic and can be scratched by abrasive cleaners Mild soap and water is recommended for general cleaning and disinfecting WARNING DO NOT use pressurized water or steam The scale system contains microprocessor circuitry and strain gauge sensors that may be adversely affected by exposure to such an environment STORAGE and TRANSPORTATION STORAGE If storing this equipment for periods longer than three 3 months remove the batteries To maintain proper operation of this instrumentation storage and transport conditions should not vary outside the following conditions Relative Humidity 0 to 85 Ambient Temperature 14 F to 122 F 10 C to 50 C TRANSPORTATION The SRV947 Portable Platform Scale has four 4 recessed
11. follow steps below STEP 1 Unlatch tab on the Battery Compartment cover on bottom of scale figure 2 STEP 2 Insert batteries according to instructions on the Battery Compartment holder STEP 3 Replace Battery Compartment cover Figure 2 Battery Compartment Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2011 SRgR Instruments Inc Model SRV947 24 X 48 Platform Scale Operating and Service Manual S N 1000 Part No MAN947_110523 Page 5 of 14 REPLACEMENT PARTS AND ACCESSORIES CA8468 Display Label MF2284T52 Replacement Feet SYSTEM DESCRIPTION AND INTENDED USE SYSTEM DESCRIPTION The SRV947 Portable Platform Scale is a low profile design 2 in height which allows the animal easy step on and off access The SRV947 Scale can be used in a fixed location or as a portable scale The Scale employs the latest in microprocessor and load cell technology to provide accurate and repeatable weight data Six 6 identically matched transducers are strategically placed to ensure an accurate representation of the patient s weight The patient s weight is displayed on an LCD screen With a push of a button weight data may be viewed in either pounds or kilograms INTENDED USE The SRV947 Portable Platform Scale is a lightweight portable scale designed for use as a weighing system for animals not
12. y other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event shall SR Instruments Inc be liable for any subsequent or special damages Any misuse improper installation or tampering shall void this warranty DAMAGED SHIPMENTS Title passes to purchaser upon delivery to Transportation Company Any claims for shortage or damage should be filed with the delivery carrier by purchaser RETURN POLICY All products being returned to SR Instruments Inc require a Return Goods Authorization number RGA To receive an RGA call our Technical Service Team at 716 693 5977 or toll free in the USA and Canada at 800 654 6360 When inquiry is made please supply model and serial numbers purchase order if the scale was bought on contract and reason for return Generally deleted damaged and outdated merchandise will not be accepted for credit A minimum restocking charge of 15 will be assessed on return of current merchandise All returns are to be shipped FREIGHT PREPAID to SR Instruments Inc 600 Young Street Tonawanda NY 14150 RESTOCKING FEE e 15 fee for any scale that has been opened and used e 10 fee for any scale returned that has been ordered incorrectly or refused delivery with no model change e 5 fee if an error in ordering has been made and a different model exchanged e No fees will be charged if the scale is returned because of an error on the part of