Home
WinPV User Guide - Power Commander
Contents
1. CHAPTER 3 F b WinPV Toolbar Cell Math Toolbar A description of the cell math toolbar buttons and functions follows press this button a Add Subtract Value yA Percent 3 36 WinPV User Guide to Add the numbered entered into the Value field to the selected cells Subtract the numbered entered into the Value field from the selected cells Divide the selected cells by the numbered entered into the Value field Multiply the selected cells by the numbered entered into the Value field Set changes the selected cells to the numbered entered into the Value field Use the Value field to enter the number you wish to change the selected cells by Percent changes the selected cells by the numbered entered into the Value field Compare Toolbar amp Load Compare Compare WORKING WITH WINPV WinPV Toolbar Compare Delta Cell Colors File 7 Table Range j Active File A description of the compare toolbar buttons and functions follows Version 7 press this button Load Compare Close Compare r Active File ig Compare File TA Delta Table Range Cell Colors to Load a tune file previously saved on your computer as the compare file Refer to To Load a Compare File Close the compare file and return to a single active tune file Active File allows you to view the active file when comparing two tune files Refer to To View the Active File Comp
2. 4 12 ee TS WinPV User Guide WORKING WITH POWER VISION Lee Power Vision Menus 5 Touch OK The Power Vision and the bike are now married 6 Touch OK Tuning Status Married to this bike Ok 7 Touch a slot to save the selected tune file Note f there is any data in the selected slot it will be overwritten 8 Touch Select to continue with the selected slot Or Touch Cancel to abort the process and return to the tune manager 9 Touch OK A copy of the current tune will be saved 10 Touch OK to continue Or Touch Cancel to abort the process and return to the tune manager Select Slot to save Stock Tune Slot 1 Empty Slot 2 Tab Slipon_KandN Filter Slot 3 Empty Slot 4 Empty Slot 5 O7TO96002412 Slot 6 O7TO096002301 Cancel s 4 13 Version 7 WinPV User Guide CHAPTER 4 yr Power Vision Menus The tune is now ready 11 Touch Flash to send the file to the ECM Or Touch Edit to edit the tune file on the Power Vision Or Touch Exit to exit the screen without any changes Tune Ready Would you now like to EDIT or FLASH this tune to the ECU 4 14 WinPV User Guide WORKING WITH POWER VISION Power Vision Menus To Edit a Tune File Edit Tune allows you to edit Dynojet Tune Custom Tune or Copy of Stock Tune files directly on the Power Vision Use the following steps to edit a tune on the Power Vision ul BhWN Turn the ignition key to the On position
3. Complete x Imported 4 4 tune items 3 13 Version 7 WinPV User Guide ACY CHAPTER 3 iF WinPV Menus To Load Selected Values Load Selected Values loads only the values from a value file that are selected in the open tune If the Value File directory does not exist or if you haven t already created the Value File directory you will need to create a Value File directory in C Program Files Power Vision Once the Value File directory is created you must map this folder in Setup Options Refer to To Setup the Options 1 Click the box next to the table you would like to load a new value file into Tune Items EA Tune Info Df Description 7 i Calibration ID H Editor Settings j i Airflow 7 i Engine Displacement 0a IAC Warmup Steps E Ide Rem L Diga Throttle Blade Control C 88 Throttle Blade Control al E Ei VE Front cyt i QJ E VE Rear Cyl D E Idle RPM Adder Fa Fuel 2 Select File gt Load Selected Values 3 Browse to your Value File folder and select the value file you wish to load 4 Click Open I ain Look in O Value Files O 2 Er Pe My Recent Documents Desktop B YEFront ppend pws amp My Documents ou My Computer Diad File name ve Front4ppend pyy X i EE Files of type Pv Tune or Value Files Cancel Places Open as read only 34 eas WinPV User Guide WORKING WITH WINPV ks WinPV Menus is 5 Click t
4. Active Compression Release Heated O2 Sensors PE Enable TPS WinPV User Guide description Set these values to the RPM at which the rev limiter will engage 6200 RPM is common for most 96ci to 103ci combinations 10250 RPM for VROD This tells the ECM if the vehicle has a Engine Idle Temperature Management System A value of zero means this vehicle does not have this feature or shuts off the input to the ECM Available in pro user level only This tells the ECM if the vehicle has Knock Control A value of zero means this vehicle does not have this feature or shuts off the knock control to the ECM A value of one means this vehicle does have this feature and the ECM will attempt to control knock This switch enables or disables Adaptive control When in closed loop the ECM will adapt to engine and environmental changes to maintain a consistent AFR This works by the ECM first using the VE table to calculate how much fuel to deliver to hit the targeted AFR value It then uses the O2 sensors to determine what the AFR actually is If there is a difference the ECM makes an adjustment and stores the difference in the adaptive fuel table The Adaptive Fuel table will develop a correction profile that is applied to the fuel calculation for each load region These values are saved in the ECM s memory and will be reloaded each time the bike is started A value of zero 0 disables adaptive control A value of one 1 enables adaptive co
5. 0 0 0 2 es 3 28 To Setup the Options a es 3 28 To Apply the License 0 0 ee 3 31 View MCMC 4 240 2 bs eee oe ee oe eB eS a 3 32 To View the Standard Toolbar 0 000 3 32 To View the Cell Math Toolbar 0 0 00 eee 3 32 To View the PowerVision Toolbar 2 0 00 ee eee 3 32 To View the Compare Toolbar 00 000 eee eee ees 3 32 To Reset the User Interface uaaa aaa a a aa ee ee 3 32 Help Menu ee 3 33 To View the About Window 0 000 cee ee ee es 3 33 To View the Power Vision Help Files 005 3 33 WinPV Toolbar ouaaa ee 3 34 Standard Toolbar 45464604 sew es b aw oe 4 oy eae ede eo 3 34 PowerVision Toolbar 0 00 ee 3 35 Cell Math Toolbar nuaa 3 36 Compare Toolbar 0 ee 3 37 Customizing the Toolbars aoaaa a 3 38 TABLE OF CONTENTS Sx e TUNE TEMS ae anena aae aa e a ar Oe Ss a aa a 3 39 TUNE AVEO 2 wy eee enei ae Gee e oie a ea E ee AE R a 3 42 AROW zerra Bue Be ts te os ie ee a ee be eek ee ee 3 42 ENVIFOMINGIE fd were ee oo dk wed ed 6 2k BS ee eae A 3 45 PC ait E P oe et E a ee a he te ee a ee ee a E 3 47 ClOSEG LOOD pestaren Baer AOE Beda hk doe ee Ge Bae a 3 49 Gear rkr ec an ee Be ee a ee Fe ee a ee ee 3 49 LIMES NG SWILCHES s 2246 62 eee ee BR Eee ek we ee EOS 3 50 SIA ait A Saat cans a LM SE a es gs Sw ee ae 3 51 CHOC Sra ae aae 8 a es Ecce ge nee ede yee ses Ara ed Sea A ne ee 3 53 SaS Bar saeara 2 At et sea ode Art OG
6. CHAPTER 3 aj Tune Items tune item Adaptive Control Minimum Temperature Hysteresis Adaptive Control Maximum Temperature Hysteresis Closed Loop Minimum Temperature Closed Loop Minimum Temperature Hysteresis WinPV User Guide description If the engine temperature gets too cold drops below this setting adaptive learning will be disabled This is usually set to Adaptive Control Minimum Temperature minus a small amount for hysteresis 5 C Adaptive Control will be re enabled when a hot engine cools to below this setting This is usually set to Adaptive Control Maximum Temperature minus 5 C Closed loop will be enabled at temperatures greater than this setting To disable closed loop completely set this value to a high temperature like 310 C 590 F Closed loop will be disabled when the engine drops below this temperature This is usually set to Closed Loop Minimum Temperature minus a small amount for hysteresis 1 5 C WORKING WITH WINPV Ls ss Tune Items Fuel tune item description Injector Size Fuel injector flow base value in grams per second This value will need to be changed for larger injectors 1 gram per second equals 7 94 pounds per hour 1 pound per hour equals 0 126 grams per second Available in pro user level only Example 1 injectors that are 4 35 grams per second are 34 5 pounds per hour Multiply 4 35 x 7 94 34 5 Example 2 injectors that are 42 pounds per hour are 5
7. Note Dynojet recommends viewing AutoTune Datalogger modes only while on a dyno mode description HITS Shows the length of time spent in each VE cell Shows the entire VE table at once VEFront Shows the VE front table as stored in the tune VERear Shows the VE rear table as stored in the tune LVE F Learned VE front LVE R Learned VE rear LCOR F Learned correction to VE front in percent LCOR R Learned correction to VE rear in percent RT Real Time is the same as HITS but zooms in and Slides the VE table around as you drive allowing you to target in on cells better To Export a Learned Tune Version 1 0 15 1184 of the Power Vision analyzes the learned values ensuring you do not exceed the maximum allowed value for any cell in the VE tables 127 5 For more information about AutoTune refer to Understanding AutoTune Use the following steps to export learned data from the AutoTUne process to a new tune in the tune manager that can be flashed to the ECM 1 From the AutoTune Session screen touch Export Learned PowerVision Application AutoTune Session 006 Tune My1 76AE LogTuned Smoothed Mode Dual Wideband Learned Spark 0 cells avg O max 0 Learned VE 1 20 cells avg 1 max 16 Enable aT if Disable at ppi Reset l E Learned oe D gt Settings Datalog 4 24 yo as ae 2 WinPV User Guide WORKING WITH POWER VISION Ta Power Vision Menus Note Step 2 will only apply if your t
8. Ya 3 RESEARCH USER GUIDE For the Power Vision and WinPV Software 2010 2012 Dynojet Research Inc All Rights Reserved User Guide for the Power Vision and WinPV Software This manual is copyrighted by Dynojet Research Inc hereafter referred to as Dynojet and all rights are reserved This manual is furnished under license and may only be used or copied in accordance with the terms of such license This manual is furnished for informational use only is subject to change without notice and should not be construed as a commitment by Dynojet Dynojet assumes no responsibility or liability for any error or inaccuracies that may appear in this manual Except as permitted by such license no part of this manual may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without the prior written permission of Dynojet The Dynojet logo is a trademark of Dynojet Research Inc Any trademarks trade names service marks or service names owned or registered by any other company and used in this guide are the property of their respective companies Dynojet Research Inc 2191 Mendenhall Drive North Las Vegas Nevada 89081 USA Printed in USA Part Number 98100016 Version 7 10 2012 TABLE OF CONTENTS Chapter 1 Welcome to Dynojet WinPV Software NOCO aed nec Pane heehee eh eee eee eee ee 1 1 Contacting Dynojet 1 a 1 1 Convention
9. 3 Select Install from a list or specific location and click Next Found New Hardware Wizard This wizard helps you install software for Power Vision v0 1 9 If your hardware came with an installation CD lt or floppy disk insert it now What do vou want the wizard to do Install the software automatically Recommended Click Next toa continue Back Cancel 2 2 WinPV User Guide GETTING STARTED ks Power Vision Driver Installation y 4 Select Search for the best driver in these locations 5 Verify the location points to your Power Vision folder in Program Files 6 Click Next Found New Hardware Wizard l J Please choose your search and installation options a ae f Search for the best driver in these locations Use the check boses below to limit or expand the default search which includes local paths and removable media The best driver found will be installed W Search removable media floppy CD ROM IM Include this location in the search C Program Files Power ison Dont search will choose the driver to install Choose thie option to select the device driver from a list Windows does not guarantee that the diver you choose will be the best match for your hardware lt Back Next gt Cancel 7 Click Finish to close the wizard Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the softwar
10. ECM part number and other vehicle specific information 1 Touch Vehicle Tools gt Vehicle Info 2 Touch Exit to return to the Vehicle Tools menu Vehicle Info VIN THDIFB SFS TGDGS A MODEL 2010FLHR TOURING ECU Partnum 343422 10 ECU CalllD 312334 10a ECU Software Level 9 ECU Farnily NextGen B 4 48 ape a WinPV User Guide To View Stored DTC s WORKING WITH POWER VISION Power Vision Menus Stored DTC s displays and allows you to clear Dealer Trouble Codes Stored DTC s can be used on multiple Delphi equipped Harley Davidson Motorcycles even after the Power Vision is married to one specific ECM Touch Vehicle Tools gt Stored DTC s Touch Read to view stored DTC s Touch Clear to erase stored DTC s Touch Exit to return to the Vehicle Tools menu 1 2 3 4 Version 7 DTCs No results to display Select an oper below to get some WinPV User Guide he 4 49 CHAPTER 4 F Power Vision Menus To Reset Trims Reset Trims resets adaptive fuel or idle trims that have been learned by the ECM Resetting these trims before a tune session is recommended 1 Touch Vehicle Tools gt Reset Trims 2 Touch Reset Fuel Trim to reset the fuel trims Or Touch Reset I dle Trim to reset the idle trims RESET RESET _ FUEL TRIM A IDLE TRIM Back 3 Touch Read to view the current information 4 Touch Exit to return to the Reset Trims screen Reset Adaptive VIN HDIFBESFS
11. The Power Vision can provide meaningful tuning feedback from either the OEM narrowband O2 sensors and or from the AutoTune module s wideband O2 sensors To Enable AutoTune To Start an AutoTune Session To Export a Learned Tune To Load a Custom Tune File To Edit AutoTune Settings 4 58 Reyna WinPV User Guide WORKING WITH POWER VISION Understanding AutoTune AutoTune Basic Without any additional modules the Power Vision will take advantage of what the ECM sees from its OEM narrowband O2 sensors and use that data to achieve the target AFR This method works great in those operating areas where it makes sense to run in a lean state idle light load and cruise conditions AutoTune Basic will fix the normal closed loop range but can also temporarily extend the closed loop range to gain insight on the actual AFR in areas that are normally open loop high load high RPM At high load high RPM ranges this temporary situation is not ideal and this is where it is advantageous to use AutoTune Pro Utilizing the AutoTune Basic AFR data and other data from the H D OEM data bus the Power Vision can automatically fix the deviation between the target AFR and actual AFR by adjusting the VE tables instead of storing the changes in an Adaptive fuel table The data is learned in real time but processing the data and adjusting the tune Is done in an offline State key on engine off After the data is collected the Power Vision can process t
12. Throttle Table Transition us Drive By Wire Speed Limit t se Ceos 1 0 79 0 82 26 5 Environment 2500 ot Pees aio ers froo oro l o0 yj Fuel 2750 86 0 85 0 eet 61 0 eee 79 5 Gee 84 5 H E Gear 3000 7 5 onenn oo O J Limits amp Switches 3500 em 7s 88 5 1 29 Spark 4000 SEES Soe ast 4500 ea fea ee ae T eof as f as T s en en e T os 5000 a ff es g0 875 s30 81 0 795 825 83 0 5500 5 870 875 a25 s05 78 5 775 775 6000 33 0 35 82 5 825 605 7a5 775 77 5 6500 AR o 35 Pes bestest ms ms ms 7000 83 0 83 5 87 Pers es eos 7s 7s rs Foc Ie TLE EAN oo c s n I c oF orc The VE table is the main table that models engine airflow so AFR can be ae calculated This table is influenced by the camshaft exhaust system head design engine displacement and air Filter This is the most critical item that must be correct in order to make the bike run correctly To increase fuel make the values larger to decrease Fuel make the values smaller 4 94 0 92 5 E 90 9 E 89 4 37 9 Bf 86 3 84 8 E 83 3 E 81 7 E 80 2 E 48 7 E 11 E 75 6 E ne 71 0 E cap Num scri 4 Version 7 WinPV User Guide 3 53 CHAPTER 3 y Status Bar Status Bar The Status Bar shows the status of the connected device PV USB link Active Mamananan 3 54 WinPV User Guide WORKING WITH POWER VISION The
13. Verify the Run Off switch is in the Run position Touch Program Vehicle gt Edit Tune Touch a tune slot to edit Touch Select to use the selected slot Or Touch Cancel to abort the process and return to the tune manager Touch parameters to edit Touch Select to edit a parameter Or Touch Cancel to abort the process and return to the tune manager Enter a new value in field Touch Save to save the new value Or Touch Cancel to abort the process and return to the tune manager 10 Touch Yes to confirm the change Or Touch No to cancel the change 11 Touch Yes to save the changes Or Touch No to cancel the change 12 Touch OK to complete the procedure Note For changes to be applied you must flash the edited tune file to the ECM Version 7 WinPV User Guide Se J 4 15 N CHAPTER 4 Ir Power Vision Menus To Check the ECM Status Status allows you to verify the connection status between the Power Vision and the ECM Use the following steps to check the status 1 Touch Program Vehicle gt Status 2 Touch Back to return to the Power Vision main menu Tuning Status Mot Married OK f 4 16 i OOOI WinPV User Guide WORKING WITH POWER VISION Sx Power Vision Menus To Enable AutoTune For more information about AutoTune refer to Understanding AutoTune Use the following steps to enable AutoTune 1 Touch Program Vehicle gt AutoTune Note Verify the Setting for AutoTun
14. 234 0 LOG VE 0 0 74 0 MAP 98 1 TPS 0 0 Mode LVEF VWER 0 0 0 0 PS 2 83 7 10 793 20 25 40 60 80 100 al a a Cad watad ce Cbd ey a T T T T g g J 9 E E J g of oo Lhe g de a Ful Leg Start r Mode Exit AutoTune Datalogger monitors various operating conditions to ensure you re ready to start auto tuning and whether or not you re in a state to allow learning A large message will overlay the screen to indicate the condition that s currently preventing learning Refer to AutoTune Datalogger Operating Conditions for a list of conditions 1000 1125 1250 1500 1750 2000 2250 2500 2750 3000 3500 4000 4500 5000 5500 S 6500 7000 PowerVision Application RPM 2638 ET 183 F LOG VERR 30 5 MAP 43 9 TPS 10 0 Mode LCORF VWED 90 5 0 0 2 3 7 10 135 20 25 30 40 60 80 100 a gr ae a ir Dhd WARMUP VE 2000000 OU GU OU ik oUi DD DD 000 62220 62868 uN T 10 11 12 1S 17 20 FF ri 27 30 33 40 45 H i 60 65 Leg Start n Mode n Exit 4 22 E MTG WinPV User Guide WORKING WITH POWER VISION Ss Power Vision Menus AutoTune Datalogger Operating Conditions The following table lists the various AutoTune Datalogger operating conditions and a description of each condition condition No Connection ET ET L ET H WARMUP AE RPM RPM L RPM H WBF WBF L WBF H WBR WBR L WBR H NBF NBF O NBR NBR
15. 29 grams per second Multiply 42 x 0 126 5 29 Air Fuel Ratio Lambda The main Lambda table directly controls fuel delivered to the engine Values at or near the stoichiometric ratio for gasoline 14 64 1 which is equivalent to a lambda value of 1 will yield the best fuel economy Lower values will result in a richer condition which is required for higher load higher RPM ranges The preferred values for best power and torque are between 86 and 92 depending on the engine combination Normally using values between 98 and 1 02 allows the ECM to maintain closed loop fuel control Example lambda of 1 14 64 AFR for gas Lambda of 89 13 1 AFR 14 64x 89 13 02 Note Lambda is independent of fuel type Acceleration Enrichment Acceleration Enrichment mode can be triggered by a sudden change in throttle position or an increase in MAP pressure To increase the fuel delivered increase the values Air Fuel Ratio Stoich The main Air Fuel table directly controls fuel delivered to the engine Values at or near the stoichiometric ratio for gasoline 14 64 1 will yield the best fuel economy Lower values will result in a richer condition which is required for higher load higher RPM ranges The preferred values for best power and torque are between 12 6 and 13 4 depending on the engine combination Using a value of 14 6 enables the ECM s ability to maintain closed loop fuel control Cranking Fuel Cranking Fuel is a multiplier based
16. 47 mpg adjustment 3 48 PE air fuel ration lambda stoich 3 48 warmup enrichment lambda 3 48 warmup enrichment stoich 3 48 fuel quick tune 4 37 G gauge limits 4 41 gauges 4 39 gear 3 49 gear ratios 3 49 speedometer calibration 3 49 gear ratios 3 49 general quick tune 4 34 get ECM data 3 21 get log 3 19 3 35 get log from pv 3 19 get tune 3 17 3 35 get tune from pv 3 17 H heated O2 sensors 3 50 help menu 3 33 about window 3 33 I IAC warm up steps 3 42 idle rom 3 43 idle rom adder 3 44 import djm pvm 3 7 import power commander map file 3 7 info 3 35 injector gas constant 3 48 injector size 3 47 interpolate 3 16 interpolate horizontal 3 16 Version 7 INDEX gy K knock control 3 50 knock control minimum temp 3 45 knock control minimum temperature hysteresis 3 45 L lambda based 3 42 limits and switches 3 50 active compression release 3 50 active exhaust 3 50 active intake 3 50 adaptive control 3 50 closed loop 3 51 EITMS 3 50 heated O2 sensors 3 50 knock control 3 50 PE disable rom 3 51 PE disable tps 3 51 PE enable rom 3 50 PE enable tps 3 50 rpm limit 3 50 load a copy of current tune file 4 12 load a copy of original tune file 4 9 load a custom tune 4 27 load a custom tune file 4 8 load all values 3 12 load compare 3 25 3 37 load selected values 3 14 lock tune 3 18 log tuner 4 22 M map default table 3 43 map load normalization 3 43 map tooth IVC front cyl 3 43 map
17. 7 WinPV User Guide x CHAPTER2 E Power Vision Tune File Management Power Vision Tune File Management There are three types of tunes that can be flashed to your ECM with the Power Vision e Dynojet Pre Configured Tunes refer to Flashing a Dynojet Pre Configured Tune File e Custom Tunes refer to Flashing a Custom Tune File e Load Copy refer to Loading a Copy of the Original Tune File or a Copy of the Current Tune File Flashing your ECM with any one of these types of tunes will automatically save a backup of your Original Tune and will permanently lock the Power Vision to your bike s ECM You can flash your ECM with tunes as many times as you like but the Power Vision will only be permitted to flash tunes to the ECM it s locked to The Power Vision s other features like data logging monitoring diagnostics clearing adaptive values etc will still be available to be used on any bike it was designed for as well as the bike it s locked to Tuning Status Married to this bike 2 12 Degen ee gee WinPV User Guide GETTING STARTED Sx Power Vision Tune File Management Any combination of the three types of tune files can be placed in the Tune Manager There are six slots in the Tune Manager and you can occupy a single slot or all six if you choose For example you could have a Dynojet Pre Configured Tune in Slot 1 a Custom Tune in Slot 2 and a Copy of Original Tune in Slot 3 You can think of the Tune
18. After the data is collected the Power Vision can process the data correct the tune and then re flash the corrected tune into the ECM Neither AutoTune Basic nor AutoTune Pro requires that you interface with a computer Power Vision sets up the AutoTune parameters monitors and logs the data and then corrects the tune to ensure that the final tune has optimum values in the VE table s 7 gt 4 59 Version 7 WinPV User Guide ay CHAPTER 4 j Understanding AutoTune AutoTune Wideband O2 Sensor Installation Options e On bikes that do not have factory closed loop fuel control O2 sensors 18mm O2 bungs must be welded into the exhaust or an aftermarket exhaust system that has 18mm 02 bungs can be installed e On bikes that have factory closed loop fuel control 18mm narrowband O2 sensors the 18mm wideband O2 sensors can simply be installed in place of the OEM sensors This requires that you temporarily or permanently disable the closed loop function of the ECM If the bike has OEM 12mm narrowband O2 sensors 18mm O2 bungs must be welded into the exhaust e Retain the OEM narrowband O2 sensors closed loop fuel control and install weld in bungs for the AutoTune wideband O2 sensors Changes Made During AutoTune The following changes are made to the tune file during the AutoTune process AutoTune Pro automatically applies a pvv to the tune that does the following e Sets the base fuel table to one static value 13 0 for AFR or
19. Checking the WinPV Update Client The Power Vision Software Feature window will appear 11 Click Next to continue Dynojet recommends you do not make any changes in this window ig Power Vision Software Setup Power Vision Software Setup Select the way you want Features to be installed Click the icons in the tree below to change the way Features will be installed f Power vision Software Suite This Feature requires OKB on your hard drive It has 2 of 3 subFeatures selected The subFeatures require S30KB on your hard drive Location C Program Files Power vision Setup is ready to install the Power Vision Software 12 Click Install to begin installation ie Power Vision Software Setup Ready to install Power Vision Software Click Install to begin the installation Click Back to review or change any of your installation settings Click Cancel to exit the wizard Version 7 WinPV User Guide Y 2 7 CHAPTER 2 Z Checking the WinPV Update Client Note Windows Vista and Windows 7 users A Windows Security warning will pop up during the installation process this is normal Click Install to continue Would you like to install this device software Name Dynojet Research Ports COM amp LPT Publisher Dynojet Research Inc E Always trust software from Dynojet Research Inc Don t Install You should only install driver software from publishers you trust How can I decide which
20. Manager as an area that holds the tunes or stages them prior to the Power Vision flashing them to your ECM You can overwrite the tunes that occupy the various slots at any time or manage your tune files in the Tune Manager by using the WinPV software Select Custom Tune to SAVE to Slot 1 Stock Read Slot 2 Tab Slipon_KandN Filter Slot 3 Empty Slot 4 Empty Slot 5 O7TO96002412 Slot 6 0O7T096002301 Cancel 2 13 Version 7 WinPV User Guide CHAPTER2 ra Power Vision Tune File Management Flashing a Dynojet Pre Configured Tune File The Power Vision is loaded with Pre Configured Tunes developed by Dynojet when it leaves our facility Dynojet makes every effort to have a tune file available for your specific combination when you receive your Power Vision pre loaded in the device but in some cases you ll need to use the Update Client to ensure you have the latest tunes available from Dynojet Refer to Checking the WinPV Update Client You can also visit http www flashyourharley com to search our tune database and download a tune for your combination Use the following steps to flash a Dynojet Pre Configured Tune to the ECM 1 Touch Program Vehicle gt Load Tune gt Dynojet Pre Configured Tunes The Power Vision will automatically search for compatible tunes Select the Type of tune to load into the tune manager L al custom ronoe TUNES COPY Cancel 2 Select a Dynojet Pre
21. Or Touch Cancel to abort the process and return to the tune manager Select Slot to save Stock Tune Slot 1 Empty Slot 2 Tab Slipon_KandN Filter Slot 3 Empty Slot 4 Empty Slot 5 O7TO96002412 Slot 6 O7T096002301 i Select Cancel 4 10 WinPV User Guide WORKING WITH POWER VISION T Power Vision Menus The tune is now ready 11 Touch Flash to send the file to the ECM Or Touch Edit to edit the tune file on the Power Vision Or Touch Exit to exit the screen without any changes Tune Ready Would you now like to EDIT or FLASH this tune to the ECU Flash i Edit Exit 4 11 WinPV User Guide Version 7 CHAPTER 4 F Power Vision Menus To Load a Copy of Current Tune File Use the following steps to load a copy of the current tune file to the Power Vision The current tune file is the tune that is currently in the ECM 1 Turn the ignition key to the On position 2 Verify the Run Off switch is in the Run position 3 Touch Program Vehicle gt Load Tune gt Load Copy _PRE CONFIGURED TUNES _ custom rono TUNES COPY Cancel 4 Touch Load Copy of Current This will load a copy of the current tune into the Tune Manager Once loaded into a slot it will be converted into a custom tune which can be edited and or flashed to the ECM Select the Type of tune to copy into the tune manager voaprcopror poxrcopyor CURRENT ORIGINAL Cancel
22. Power Vision incorporates a very sophisticated yet simple touch screen display that does not require the use of a computer to flash your bike Simply select the tune and follow the on screen prompts to download the tune and if you d like edit your tune without ever touching a computer Anyone of the three types of tunes outlined below is able to be edited on the device or in the WinPV Tuning Application Power Vision downloads and stores the stock calibration allows you to select up to five different tunes that are stored on the device and can be flashed to your bike The types of tunes include Dynojet Pre configured Tunes Tunes for YOUR bike pre loaded on the device ready to go right out of the box Power Vision identifies your bike s information and automatically sorts hundreds of applicable dyno proven tunes for you to choose from Custom Tunes loaded by a custom tuning shop or received via email and loaded on the device Copy of Stock a version of the stock calibration that is editable Power Vision provides insightful valuable information on how your bike is running Display all J 1850 H D vehicle data H D CAN vehicle data as well as wideband AFR and various calculated channels such as MPG instant and trip MPG a virtual gauges allow data to be monitored live and or logged while riding User defined visual alarms for any data channel example if knock exceeds two degrees or if Cylinder Head Temp exceeds 280
23. Se ere amp 3 54 Chapter 4 Working with Power Vision Power Vision MenusS 0 a 4 2 Program Vehicle Menu arriti praata ae es 4 4 To Load a Dynojet Pre Configured Tune File 4 4 To Load a Custom Tune File 0 a eee eee ee es 4 8 To Load a Copy of Original Tune File 4 9 To Load a Copy of Current Tune File 2005 4 12 TOEdita UG Flle cs sievss ot vara a acne Gotome Bowe ake a Sea See 4 15 To Check the ECM Status 0 0 cee ee ee ees 4 16 To Enable AutoTune 0 00 eee ee ee ees 4 17 To Start an AutoTune Session 0 00 eee eee ees 4 21 To Export a Learned Tune 2 00 ee ee es 4 24 To Load a Custom Tune File aa eee ee ee es 4 27 To Edit AutoTune Settings 2 000 eee ees 4 29 To Configure Quick Tune 2 a ee 4 34 Datalog Menu 1 ee 4 39 To View GaugeS 4 4 4 524 Ai be eR PE REE aK ee BS 4 39 To Create Gauge Limits and Visual Warnings 4 41 TO Playback a LOG sunk btat ean eeb as haw oe awe Yare 4 45 TO VIEW SIGWIGNS tical a oe a at Se ee a 4 46 To Reset Trip Economy A aaau a 4 46 To Reset Trip Economy B saaana a 4 47 To Create a Log with Power Vision 000 00 ee eee 4 47 To Return to the Power Vision Main Menu 055 4 47 Vehicle Tools Menu s padega ii pee e a ee aN 4 48 To View Vehicle Info 1 es 4 48 To View Stored DIC S ecto ccetiia gi tankia ne eea oa 4 49 MOVRGSCO TANS er
24. To View the Active File Active File allows you to view the active file when comparing two tune files Select Compare gt Active File or click the Active File button A i Active File 3 25 Version 7 WinPV User Guide ny CHAPTER 3 ny WinPV Menus To View the Compare File Compare File allows you to view the loaded compare file when comparing two tune files The Compare File cannot be edited 7 Compare File Select Compare gt Compare File or click the Compare File button To View Delta Delta shows the difference between the active file and the compare file for the tune item you have selected By editing the delta file you can change the active file For example if one of the cells in the delta file is 10 and you change it to 15 the corresponding cell in the active file will change by 5 In Delta a positive number indicates the value in the compare file is larger than the value in the active file Hover the mouse pointer over a cell to view the comparison of the numbers Active number is first then the compare number a ae 32 13 1 6 9 89 5 vs comparison of 94 3 3 9 eae 15 fee a 1 0 2 2 2 4 3 6 Select Compare gt Delta or click the Delta button a Heita To Choose Cell Colors 1 Click the Cell Colors button 3 Pange Cell Colors 2 Using the drop down arrow select the cell color option from the list None uses no colors Table Range uses colors from blue to red based on lowest to highest numbers
25. Tune Info H E Editor Settings Fy Airflow H Fuel H Gear fy Limits amp Switches FE Spark Advance Front Cyl FE Spark Advance Rear Cyl D ai Max Knock Retard if Adaptive Knock Retard 2 Select File gt Save Selected Values 3 Enter a file name and click Save ux Save in Value Files o 2 em Fe 4 IdleRPM pyy RPMLimit pyv My Recent YEIdleRPMLimit pyv Documents Desktop My Documents or My Computer e My Network File name filename pyv Places Save as type Harley PY Value File pvv Cancel 3 10 WinPV User Guide WORKING WITH WINPV Sx WinPV Menus gt To Save Selected Values Append Value Files are one or more tables that are selected in WinPV Save Selected Values Append creates a new value file using an existing value file as a base The value file you select changes the cell values in the base file to any cell values that are different in the selected file If the Value File directory does not exist or if you haven t already created the Value File directory you will need to create a Value File directory in C Program Files Power Vision Once the Value File directory is created you must map this folder in Setup Options Refer to To Setup the Options Save Selected Values Append creates a new value file using an existing value file as a base The value file you select changes the cell values in the base file to any cell values that are diff
26. Would you now like to EDIT or FLASH this tune to the ECU Flash i Edit Exit 11 Touch OK 12 Turn the ignition key off and wait ten seconds Turn Key OFF Please Turn Key Off and wait 10 seconds before turning key back on 4 7 WinPV User Guide Version 7 FJ CHAPTER 4 a9 a Power Vision Menus To Load a Custom Tune File The Power Vision accepts custom tune files created in the WinPV software or by Dynojet dealers Use the following steps to load a custom tune file to the ECM ul hWN Turn the ignition key to the On position Verify the Run Off switch is in the Run position Touch Program Vehicle gt Load Tune gt Custom Tunes Touch a Custom tune file to load Touch Select to continue with the selected Custom tune file Or Touch Cancel to abort the process and return to the tune file screen Touch a slot to save the selected tune file Note f there is any data in the selected slot it will be overwritten Touch Select to continue with the selected slot Or Touch Cancel to abort the process and return to the tune manager Touch OK to continue Or Touch Cancel to abort the process and return to the tune manager The tune is now ready Touch Flash to send the file to the ECM Or Touch Edit to edit the tune file on the Power Vision Or Touch Exit to exit the screen without any changes 10 Touch OK 11 Turn the ignition key off and wait ten seconds 12 Turn the ignition key back on 4 8
27. and WinPV software Note You must flash a tune to the ECM before using Quick Tune Once a tune is flashed to the ECM the tune is stored in a buffer allowing you to use the Quick Tune feature 1 Touch Program Vehicle gt Quick Tune 2 Touch General Use the General tab to set the Idle Offset Rev Limit and Reset Adaptive Fuel Tables 2a Using the up or down arrows increase or decrease the Idle Offset Idle Offset changes the RPM at which the engine will idle A positive number increases the idle and a negative number decreases the idle 2b Using the up or down arrows increase or decrease the Rev Limit Rev Limit changes the RPM at which the rev limiter engages A positive number increases the rev limit and a negative number decreases the rev limit 2c Click the box to reset the Adaptive Fuel Tables Resetting the Adaptive Fuel Tables clears the corrections the ECM has made based on readings from the factory narrow band O2 sensors PowerVision Application General Config Idle Offset 0 RPM Rev Limit 6200 0 RPM Reset Adaptive Fuel Tables EA Continue 4 34 WinPV User Guide WORKING WITH POWER VISION es Power Vision Menus h 3 Touch Config Use the Config tab to set the ACR Auto Compression Release Heated O2 VSS Active Intake and Active Exhaust 3a Click the box to enable disable ACR Auto Compression Release 3b Click the box to enable disable Active Intake 3c Click the box to enable d
28. cause oil pressure to drop This normalizes the MAP reading to better represent LOAD in a range 0 100 You do a WOT run through the RPM range and record MAP then you set this table so that the same test would then read 100 across the board This defines when the primary MAP reading is taken This Should be set to the crank tooth number near intake valve closing for the front cylinder This defines when the MAP reading used for Charge Dilution Effect is taken which smooths out the VE table at low loads This should be set to be the crank tooth number just before intake valve opening for the front cylinder This is how many crank teeth to offset the MAP Tooth IVC and MAP Tooth IVO teeth for the rear cylinder This is not editable The MAP Default table gives normalized VE values in the event the MAP sensor fails The number of reference teeth on the flywheel including the gap This not editable 32 Big Twin 24 VROD This is used in drive by wire systems This table represents the desired throttle percent as a function of RPM Throttle Blade Control Stage II is used once the throttle transition gear has been reached Drive by wire Harleys use two throttle blade control tables To use Throttle Blade Control Stage ll exclusively set Throttle Transition Gear to 0 This is used in drive by wire systems This table represents the desired throttle percent as a function of RPM Throttle Blade Control Stage is used until the thr
29. copy of the original tune loaded before importing a Power Commander map file 2 Select Tune Info from the Tune Items manager and click Description If the Strategy is 9 44 or 218 the Power Commander map file will not import When the existing VE tables are RPM versus MAP KPA you will not be able to import Power Commander map files The example below shows a strategy of 9 and will not work when importing a Power Commander map file Dynojet Power ision WinP 10 FB4 QEBsAZ6E 01 p t E File Edit PowerVision Compare Setup View Help os Hu a O82 BO o le amp f gt Open Save Cut Copy Paste Print About Info GetTune SendTune gS E TE Ta Table Range 2 Load Close Compa re Delta Cell Colors z Compare Compare File Subogenerated From Ela Tune Info vin LHDIFB41 346609455 e CIE Description ECU 34245 10 7 aii Calibration I0 Strategy 9 H E Editor Settings E Airflow CE Engine Displacement Oj IAC Warmup Steps 8 Idle RPM Ea C Throttle Blade Control 2 O Throttle Blade Control Al z Oi VE Front Cyl i mm E VE Rear Cyh eo tf Idle RPM Adder Ey Fuel lti Injector Size JE Air Fuel Ratio Lambda 3 Select File gt I mport Power Commander Map 4 Select a file to open 5 Click Open Select Power Commander Map to IMPORT 2 xi My Recent Documents Desktop amp My Documents ar ea My Computer re File name Sportster pvm S My Network Files of
30. device software is safe to install 13 The Power Vision Software update is now complete Click Finish to exit the Setup Wizard 2 8 WinPV User Guide GETTING STARTED Ss Installing the Power Vision on the Motorcycle Installing the Power Vision on the Motorcycle The following installation was performed on a 2008 Harley Davidson Night Rod Your bike and set up May vary Note The Power Vision may be damaged if installed improperly To ensure safety and accuracy in the procedures perform the procedures as they are described 1 Connect the PowerVision to the ECM s diagnostic port The location of the diagnostic port varies depending on the model Please refer to the following table or consult your service manual for the exact location model 2001 2013 Softail models 2004 2013 Dyna models 2007 2013 Sportster models including XR models 2002 2013 V Rod models 2002 2007 Touring models 2008 2013 Touring models Version 7 diagnostic connector location Diagnostic connector is located under the seat attached to the frame by the rear fender This connector is light grey in color with a black rubber plug installed Note Requires removing the seat Diagnostic connector is located behind the left hand side cover This connector is light grey in color with a black rubber plug installed Diagnostic connector is located behind the left hand side cover This connector is light grey in color with a black rub
31. display in the 3 D representation below the table ka Table 3 Select a cell or group of cells copy those values and paste those values in different cell s For more information about changing cell values refer to To View the Cell Math Toolbar 4 You may also select a cell or group of cells and type values into those cells For more information about changing cell values refer to To View the Cell Math Toolbar Dynojet Power ision WinP untitled pyt File Edit PowerVision Compare Setup View Help e adieae fl B o it gt mo fl A Open Save Cut Copy Paste Print About E Add Subtract Divide Multiply Set Value Percent p EI ki ki 3 B ig a Table Range X Info GetTune Send Tune ga Get Log Z Load Close Compare Delta Cell Colors A 3 Compare Compare File X Tune Items ui YE Front Cyl J Apply CHANGES to VE Rear Cyl 0 Tune Info untitled pyt Airflow Da ic wampseps 1 IAC Warmup St Pie E 750 T 74 0 a 740 745 74 0 e 740 74 0 E ii 1000 sapan ee 74 5 O Throttle Blade Control Os Throttle Blade Control Al es res reo eo reo rel ss so as T aso aso 75 0 70 75 775 770 765 so zo rss rss 760 76 0 1500 0 795 790 785 5 0 1750 73 0 805 805 80 0 795 o 70 zo mo rro ois 2000 745 820 815 81 0 805 1125 1250 Imp Ve Front cyl O VE Rear Cyl O h Idle RPM Adder tf
32. easily develop new fuel and ignition maps record and download log files and increase performance with the click of a button Whether you are new to the benefits of dyno testing and tuning or an experienced performance leader the Power Vision in conjunction with the WinPV software will give you the professional results you are looking for WinPV Help provides information and step by step guidance for common tasks as well as descriptions of each field on each window Notice Copyright 2010 2012 Dynojet Research Inc All Rights Reserved The Dynojet logo is a trademark of Dynojet Research Inc The Power Vision is approved for racing vehicle use only WinPV Help 2012 10 29 07 Document Part Number 98100016 07 Contacting Dynojet Please contact us with your questions and comments If you need assistance with an issue please contact Dynojet Technical Support Telephone 800 992 4993 Email pvtech dynojet com WinPV User Guide 1 1 a CHAPTER 1 Website www dynojet com www flashyourharley com Write to us 2191 Mendenhall Drive North Las Vegas NV 89081 Conventions WinPV Software documentation uses consistent conventions to help you identify items The following table summarizes these conventions example of convention description Bold Highlights items you can select on in the software interface including buttons and menus gt The arrow indicates a menu choice For example select File gt Open mea
33. h To Start an AutoTune Session You can define when AutoTune is active by adjusting various settings For more information refer to To Edit AutoTune Settings For more information about AutoTune refer to Understanding AutoTune The values learned during the AutoTune process will automatically save e Every five minutes e When the vehicle comes to a stop during a drive cycle The values learned during the AutoTune process will also save when you e Press the mode button e Turn datalogging on or off e Exit the green screen e Disable AutoTune Use the following process to start an AutoTune session Touch Program Vehicle gt AutoTune gt Datalog PowerVision Application AutoTune Session 006 Tune My1 7 6A4E LogTuned Smoothed Mode Dual Wideband Learned Spark 0 cells avg O max 0 Learned VE 1 20 cells avg 1 max 16 Enable AT i i Disable AT i ppi For Reset Learned lt Settings Datalog 4 21 Version 7 WinPV User Guide CHAPTER 4 Power Vision Menus AutoTune is now active and will start learning anytime you are in the AutoTune Datalogger screen shown below The AutoTune Datalogger screen indicates the learning process is active and you re on your way to perfecting your tune Note You have the option to create a log file by touching Log Start to log channels required for Log Tuner You do not need to select Log Start in order to start the AutoTune process PowerYision Application RPM 0 ET
34. in the table Modified must have a compare file loaded to use Compare High Low uses colors to represent the differences between the compare files White is no difference while blue is the largest difference Compare High Low is only available when a compare file is loaded 3 26 ODOT WinPV User Guide WORKING WITH WINPV Ls ss WinPV Menus To Show Only Differences Show Only Differences allows you to view only the tune items with differences in the tune items Select Compare gt Show Only Differences To Show Delta As Percent Show Delta as Percent allows you to view the differences as a percent Select Compare gt Show Delta As Percent To Create Difference Report Create Difference Report allows you to create a text file containing the tune items and the differences between the Active file and the Compare file Select Compare gt Create Difference Report 3 27 Version 7 WinPV User Guide aN CHAPTER 3 iF WinPV Menus Setup Menu To Setup the Options 1 Select Setup gt Options 2 To change the Units 2a Using the drop down arrow select either Metric or Imperial 2b Click OK to accept the changes Property Value EE Metric User Level Stock Files Folder Metric Tune Files Folder C Program Files sPower Vision Tune Files Value Files Folder EA Units One of Imperial or Metric 3 To change the User Level 3a Using the drop down arrow select either Basic or Pro 3b Cli
35. the gear that Throttle Blade Control Table Stage will transition to Throttle Blade Control To use the throttle blade control table only change this value to O When the Rev Limit is approaching Drive By Wire DBW bikes nudge the throttle towards this position specified for each gear Set these to 100 to remove this limit or to a value that works with your desired rev limit This is the speed limit for vehicle protection based on gear Set this to what you want the vehicle speed limit to be in gears one through six Environment tune item EI TMS On Temperature EITMS Off Temperature Knock Control Minimum Temperature Knock Control Minimum Temperature Hysteresis Adaptive Control Enable Temperature Adaptive Control Maximum Temperature Version 7 WORKING WITH WINPV Ls ss Tune Items description The Engine Idle Temperature Management System EI TMS On Temp reduces heat buildup during prolonged idling times and controls heat buildup in two stages Mode 1 AFR Enrichment is activated when the engine temperature exceeds 142 C Sportsters 230 C and the engine RPM is less than 1200 RPM Mode 2 Skip Fire Big Twins only activates if Mode 1 is active and the engine temperature exceeds 155 C and the vehicle speed is less than 1 2 KPH Note Sportster temperatures are much higher due to the location of the temperature sensor and only uses EITMS Mode 1 AFR Enrichment When Mode 2 Skip Fire is active add
36. the process and return to the tune manager PowerVision Application Step 2 Which Autotune mode Select installed O2 Sensor Style Basic uses the OEM Narrowband O2 sensors tuning to temporary stoich 14 6 Air Fuel ratio Pro uses Dynojet Widebands for tuning using a wider Air Fuel Ratio range 4 19 Version 7 WinPV User Guide aT CHAPTER 4 JH Power Vision Menus 6 Touch Continue to send the file to the ECM or touch Cancel to exit the screen without any changes The tune is modified to be compatible with the mode you chose from above Note The Power Vision must be connected to the vehicle with the key and run switch in the on position with the engine not running WARNI NG Do not turn off the ignition or interrupt the power during this process This can cause irreversible damage to the ECM PowerVision Application Step 3 Flash ELM This will modify the tune for Autotune and load it onto the Vehicle The vehicle must be connected to the PV for this step i Continue i Cancel 7 Once the process is complete you will be prompted to turn the key off and wait ten seconds Touch OK 8 Turn the ignition key off and wait ten seconds 9 Turn the ignition key back on AutoTune is set up PowerVision Application Autotune ENABLED Please Turn Key OFF and wait 10 seconds before turning key back on mails 4 20 WinPV User Guide WORKING WITH POWER VISION es Power Vision Menus
37. type PC3 5 Map Files dim pvm Cancel Places Il Open as read only 3 7 Version 7 WinPV User Guide xy CHAPTER 3 r WinPV Menus 6 Click Yes to swap the Front Rear import order Or Click No to import as shown in the window Swap Import Order x PL MOTES 200 2008 Harley Davidson Sportster 1200 4dvanced Map TABLES Fuel Table 1 gt Front YE Table Fuel Table 2 gt Rear VE Table would vou like to SWAF the Fronti Rear import order Press YES to SWAF them Press NO to continue with import as shown above Or Press CAMCEL to CAMCEL IMPORT The Import Complete window will appear This window will explain which tables were imported where how many cells were switched to 14 5 and how many imported values exceeded the VE Table range The maximum value in a cell is 127 5 If you see 127 5 in a cell you know the imported Power Commander map tried to exceed that value 7 Click OK Ce Imported Items OF table 1 gt Front WE table AF table 2 gt Rear VE table Switched 2835 4FR 14 6 cells to 14 5 Import CLIPPING error 10 68 TIP large CLIPPING error means the imported values exceeded the VE Table range IF you get this the VE Tables Displacement SFR may need to be adjusted prior to importing this MAP 3 8 DOTA 3 WinPV User Guide WORKING WITH WINPV Sx WinPV Menus 3 To Save All Values Value Files are one or more tables that are selected in WinPV Save All Values w
38. 106 H Gear E E Limits amp Switches 1000 Sy Spark 112 1000 160 1000 176 i000 192 1000 WO im Click the plus sign to expand the items click the minus sign to compress the items Click on the desired tune item to view that item Many tune items are described in this section Tune Items H Tune Info Fy Editor Settings Eley Airflo oe C i Engine Displacement C 8 14 Warmup Steps CH Idle RPM s C E Throttle Blade Control C E Throttle Blade Control al E VE Front cyl hC E Idle RPM Adder H Fuel H Gear Fly Limits amp Switches Boy Spark 3 40 WinPV User Guide WORKING WITH WINPV Ss es Tune Items When using the compare feature a colored flag may be visible next to certain tune items These visual identifiers helps you distinguish parameters that don t match when using the compare feature Visual identifiers offer a quick and easy way to identify where the tune has changed You must have a compare file open to use the visual identifiers For more information about the compare feature refer to To Load a Compare File There are three visual identifiers e Yellow Flag different e Green Flag does not exist in the compare file but does exist in the active file e Red Flag exists in the compare file but does not exist in the active file Tune Items Tune Info Ny Airflow A Drive By Wire Speed Limit e Cv Engine Displacement CIA IAC War
39. 32 3 34 copy 3 34 customizing 3 38 cut 3 34 open 3 34 paste 3 34 Save 3 34 start autotune 4 21 Status bar 3 54 Stock files 3 29 stored DTCs 4 49 Subtract 3 36 switch 3 39 T table range 3 26 tables 3 40 technical support 1 1 throttle blade control stage 3 43 throttle blade control stage II 3 43 throttle table transition gear 3 44 touch calibrate 4 55 touch screen 4 55 tune file 4 5 4 18 tune files 3 30 tune info 3 42 calibration ID 3 42 description 3 42 lambda based 3 42 software level 3 42 tune items 3 39 3 53 airflow 3 42 closed loop 3 49 environment 3 45 fuel 3 47 gear 3 49 limits and switches 3 50 scalar 3 39 Spark 3 51 switch 3 39 tables 3 40 tune info 3 42 visual identifiers 3 41 tweaks quick tune 4 36 Version 7 INDEX gy U undo 3 16 units 3 28 4 53 update client 2 5 update tune using pv 3 21 user level 3 28 options 3 28 V value 3 36 value files 3 31 VE front 3 43 VE rear 3 44 ve quick tune 4 38 vehicle info 4 48 vehicle tools menu read ecm 4 51 reset trims 4 50 restore original tune 4 52 stored DTCs 4 49 vehicle info 4 48 view gagues 4 39 view menu 3 32 cell math toolbar 3 32 compare toolbar 3 32 pv toolbar 3 32 reset ui 3 32 standard toolbar 3 32 visual identifiers 3 41 visual warnings 4 41 W warmup enrichment lambda 3 48 warmup enrichment stoich 3 48 WinPV menus 3 3 compare menu 3 25 edit menu 3 16 file menu 3 5 help menu 3 33 powervision menu 3 17 setup
40. 4 O7TOSB00e2306 pvt Notes Strategy 44 ECU 34245 111 Year 2011 Family TOURING SE Air Cleaner Rush True Duals 2 baffels Economy 91 93 Octane s Cancel The Tune is now ready Touch Flash to flash this tune to the ECM Note During the flash process do not turn off the bike Once complete you will be prompted to turn the bike off for 10 seconds Or Touch Edit to edit this tune Or Touch Exit to exit the screen without any changes Would you now like to Edit or Flash this tune to the ECM Flash i Edit Exit Note You can edit any tune that s loaded in the Tune Manager prior to flashing your ECM The Power Vision allows you to make basic adjustments to your tunes directly on the device without using a computer In order to gain full access to your tune files you ll need to download them from the Power Vision to WinPV our custom tuning software WinPV User Guide GETTING STARTED Power Vision Tune File Management Loading a Copy of the Original Tune File or a Copy of the Current Tune File The Power Vision will allow you to load either a Copy of Current tune or a Copy of Original tune files The Copy of Original tune file is a copy of the tune that was present in your ECM when the Power Vision first locked to your ECM In other words it is a copy of the backup file that was created and stored in the Power Vision This is a great way for those who are happy with the way their bike runs but want
41. 89 lambda e Disables EI TMS PE Adaptive Control e AE DE are still active in the tune but there s logic to disable or minimize learning when they re active AutoTune Basic automatically applies a pvv to the tune that does the following e Sets the base fuel table to 14 6 for AFR based calibrations and 982 for lambda based calibrations e Disables AE DE EITMS PE Adaptive Control e Retards 4 degrees of timing e Bias the close loop range to 700mv on AFR based calibrations General e Sets calib to PVAT Session Number e Clears adaptive fuel tables after flashing 4 60 eyes WinPV User Guide WORKING WITH POWER VISION Les Understanding AutoTune AutoTune Notes and Tips e AutoTune can use the ECM s ion sensing knock control strategy in order to remove timing adjust spark advance from areas of your calibration where knock was present This feature can only remove timing it will never add it It is not recommended to use this feature with AutoTune Basic only AutoTune Pro This feature is disabled by default but changing the Max Spark Learn from O to a value such as 10 would make it active e If you do not have Wideband O2 sensors installed ie those included in the Dynojet AutoTune kit select Basic mode e The default values are acceptable for most big twin models If you have a V Rod or Sportster you will need to adjust the temperature in degrees C and RPM limit to an acceptable range Refer to To Edit AutoTune S
42. Configured Tune File to flash 3 Touch Select Select Dynojet Tune to Load 07T096000101 07T096000301 Ux 07T096002301 E 07T096002302 07T096002304 07TO96002305 07T096002306 07T096002307 F 07T096002308 Select Cancel NT CTG WinPV User Guide GETTING STARTED he Power Vision Tune File Management 4 Verify the tune information If the tune information is correct touch Continue 07TOS600e2306 pvt Notes Strategy 44 ECU 34245 111 Year 2011 Family TOURING SE Air Cleaner Rush True Duals 2 baffels Economy 91 93 Octane Continue s Cancel 5 Select a slot to save the selected tune file Note f there is any data in the selected slot it will be overwritten 6 Touch Select Select Custom Tune to SAVE to Slot 1 Stock Read Slot 2 Tab Slipon_KandWN Filter Slot 3 Empty Slot 4 Empty Slot 5 O7TO96002412 Slot 6 O7 TO96002301 Cancel The tune is now ready 2 15 Version 7 WinPV User Guide r 7 2 16 x CHAPTER 2 amp Power Vision Tune File Management Touch Flash to flash this tune to the ECM Note During the flash process do not turn off the bike Once complete you will be prompted to turn the bike off for 10 seconds Or Touch Edit to edit this tune Or Touch Exit to exit the screen without any changes Would you now like to Edit or Flash this tune to the ECM Flash i Edit Exit Note You can edit any tune that
43. Edit gt Smooth to smooth the selected values To Interpolate Selected Values nterpolate is a function that applies a linear interpolation to the values within the range of selected cells This function will also construct new values within the range of selected cells when surrounded by valid values positive or negative integers 1 Select the desired values You must select at least three cells 2 Select Edit gt I nterpolate to interpolate the selected values To Interpolate Selected Horizontal Values 1 Select the desired values You must select at least three cells that are horizontal 2 Select Edit gt I nterpolate Horizontal to interpolate the selected values To Interpolate Selected Vertical Values 1 Select the desired values You must select at least three cells that are vertical 2 Select Edit gt I nterpolate Vertical to interpolate the selected values 3 16 ODOT WinPV User Guide WORKING WITH WINPV T WinPV Menus 5 PowerVision Menu To View the PowerVision Information 1 Select PowerVision gt PV Info or click the Info button amp 2 Click Refresh to refresh the information displayed Info 3 Click Exit to exit the PV Info window Serial AMAJRO00AA001248 FILES version 106 Product Mame Dynojet Power Vision Product Rey 0 Tuning Enabled yes Refresh Locked to VIN na Enabled PINS 000000001 Free Storage 95 Firmware Build Date Dec 20 2010 16 10 25 Firmware version 0 0 34 514 Bootloader ve
44. O VE VE MAP L Version 7 description The ECM is not responding The engine temperature Is not reading The engine temperature Is too low The engine temperature is too high The ECM is still using warm up tables The ECM is using acceleration enrichment tables The engine speed is not reading The engine speed is too low The engine speed is too high The Wideband O2 sensor front is not ready The Wideband O2 sensor front too low less than lambda 0 68 This is usually during warm up The Wideband O2 sensor front too high over lambda 1 22 This is usually during heavy deceleration The Wideband O2 sensor rear is not ready The Wideband O2 sensor rear too low less than lambda 0 68 This is usually during warm up The Wideband O2 sensor rear too high over lambda 1 22 This is usually during heavy deceleration The OEM narrowband sensor front is not ready The OEM narrowband sensor front in open loop The OEM narrowband sensor rear is not ready The OEM narrowband sensor rear in open loop Unable to match current conditions to a VE table cell The conditions are changing too rapidly or moving between VE table cells The map sensor is reading too low usually deceleration Map lt 20 KPA 4 23 WinPV User Guide CHAPTER 4 i amp Power Vision Menus AutoTune Datalogger Modes The following table lists the various AutoTune Datalogger modes and a description of each mode
45. STGDGS a MODEL 2010FLHR TOURING ECU Partnum 343422 10 ECU CalllD 312334 10a ECU Software Level 9 ECU Family NextGen B 5 Touch Back to return to the Vehicle Tools menu 4 50 Caan Dagens get WinPV User Guide WORKING WITH POWER VISION Ta Power Vision Menus To Read ECM Read ECM is for development purposes only and should only be selected when instructed by a Dynojet Technician 1 Touch Vehicle Tools gt Read ECM 2 Touch Yes to continue Or Touch No to return to the Vehicle Tools menu This will read data in your ECM The files that are read from the ECM are for diagnostic and development purposes only Continue 4 51 Version 7 WinPV User Guide N CHAPTER 4 SE Power Vision Menus To Restore Original Tune Restore Original Tune allows you to restore the factory ECM calibration 1 Touch Vehicle Tools gt Restore Original Tune 2 Touch Yes to restore the original tune to your ECM Or Touch No to return to the Vehicle Tools menu Restore Original Tune This will restore the Original tune to your ECM The Original Tune is the file that was present in your ECM when the Power Vision first locked to your ECM Continue To Return to the Power Vision Main Menu Touch Back 4 52 WinPV User Guide WORKING WITH POWER VISION Sx Power Vision Menus Settings Menu To Select the Units Units sets all Power Vision units to either Metric or English 1 Touch Settings gt U
46. WinPV User Guide WORKING WITH POWER VISION Sx Power Vision Menus h To Load a Copy of Original Tune File Use the following steps to load a copy of the original tune file to the Power Vision The original tune file is the tune that was saved when the Power Vision married to the ECM 1 Turn the ignition key to the On position 2 Verify the Run Off switch is in the Run position 3 Touch Program Vehicle gt Load Tune gt Load Copy Select the Type of tune to lad into the tune manager Ps j F jaa aa e _PRE CONFIGURED TUNES custom ronD TUNES COPY Cancel 4 Touch Load Copy of Original This will load a copy of the original tune into the Tune Manager Once loaded into a slot it will be converted into a custom tune which can be edited and or flashed to the ECM Select the Type of tune to copy into the tune manager voaprcopror poxrcopvor CURRENT ORIGINAL Cancel es 4 Version 7 WinPV User Guide wey CHAPTER 4 E Power Vision Menus 5 Touch OK The Power Vision and the bike are now married 6 Touch OK Tuning Status Married to this bike s Ok 7 Touch a slot to save the selected tune file Note f there is any data in the selected slot it will be overwritten 8 Touch Select to continue with the selected slot Or Touch Cancel to abort the process and return to the tune manager 9 Touch OK A copy of the stock tune will be saved 10 Touch OK to continue
47. access to their existing tune in order to make a few adjustments The Copy of Current tune file is a copy of the current tune that has been flashed to your ECM Use the following steps to load and flash either a Copy of Original tune or a Copy of Current tune file to the ECM 1 Touch Program Vehicle gt Load Tune gt Load Copy Select the Type of tune to liad into the tune manager ee ee a l a Fy SH a L alt i PRE CONFIGURED TUNES ao ream F custom ron TUNES COPY Cancel 2 Touch Load Copy of Current or Load Copy of Original Select the Type of tune to copy into the tune manager voAD COPYOrF voxrrcopyor CURRENT ORIGINAL Version 7 Fs WinPV User Guide 2 19 x CHAPTER 2 amp Power Vision Tune File Management 3 Select a slot to save the tune file Note f there is any data in the selected slot it will be overwritten 4 Touch Select to continue Select Slot to save Stock Tune Slot 1 Empty Slot 2 Tab Slipon_KandN Filter Slot 3 Empty Slot 4 Empty Slot 5 O7TO96002412 Slot 6 O7T096002301 i Select Cancel The Tune Is now ready Select Flash to flash this tune to the ECM Note During the flash process do not turn off the bike Once complete you will be prompted to turn the bike off for 10 seconds Or Touch Edit to edit this tune Or Touch Exit to exit the screen without any changes Would you now lik
48. annel from the list 3b Touch Remove to delete the channel from the data logging global signal list 4 To add a channel to the current list 4a Touch Add to add a channel not in the current list 4b Use the Set Global Signal Properties screen to select and set up a channel For more information about creating a gauge channel refer to To View Gauges 4c Touch OK to return to the Data Logging Global Signals screen 5 Touch Exit to return to the Datalog menu To Reset Trip Economy A Reset Trip Economy A resets the tripometer and fuel economy meter in the Power Vision Touch Datalog gt Reset Trip Eco A 4 46 OOC 3 WinPV User Guide WORKING WITH POWER VISION Le Power Vision Menus To Reset Trip Economy B Reset Trip Economy A resets the tripometer and fuel economy meter in the Power Vision Touch Datalog gt Reset Trip Eco B To Create a Log with Power Vision The Dynojet Power Vision has internal logging capabilities when monitoring gauges 1 Touch Datalog gt Gauges 2 Using the left or right arrows at the bottom of the screen select gauge you would like to use 3 Touch Start Log to begin logging Touch End Log to stop logging 5 Touch Exit to return to the Datalog menu To Return to the Power Vision Main Menu Touch Back 4 47 Version 7 WinPV User Guide ve CHAPTER 4 a Power Vision Menus Vehicle Tools Menu To View Vehicle Info Vehicle Info stores VIN data ECM family information model number
49. ar aeto AT be ba cuil beana i taala e teat had rat bm corect i Bobne fuel ane he vikri npr 3 D representation of the table aA status bar fae 32 ee G WinPV User Guide WORKING WITH WINPV he WinPV Menus WinPV Menus The menu bar displays the seven menus available in WinPV File Edit PowerVision Compare Setup View and Help Each menu contains groups of related commands Many commands are followed by keyboard shortcuts As you use WinPV you will develop your own working style Maybe you will prefer to use the mouse and menu commands or you may find that you prefer the quick access to features provided by keyboard commands Depreeget Foram Tisia Bier F entitled pret menu har File Edi Parerinian Compan Hup Mew Halp Ssimnimnande Sa u cm keyboard shortcut Pii ran Ba em a Fel ia Pei ig Cri a i Ti Tat jo Sheek FPM La rn mo ww p EETA TES Ta r Use the following menus and commands with WinPV E File Edit PowerVision Compare Setup View Help File Menu To Open a Power Vision Tune File PVT To Save a Power Vision Tune File PVT To Import a Power Commander Map File pvm djm To Save All Values To Save Selected Values To Save Selected Values Append To Load All Values To Load Selected Values To Exit the WinPV Software Edit Menu To Undo To Cut Copy Paste Selected Values To Smooth Selected Values To Interpolate Selected Values To In
50. are File allows you to view the loaded compare file when comparing two tune files The Compare File cannot be edited Refer to To View the Compare File Show the difference between the active file and the compare file for the tune item you have selected Refer to To View Delta Change the colors of the cells in the table Refer to To Choose Cell Colors o WinPV User Guide 3 37 aN CHAPTER 3 iF WinPV Toolbar Customizing the Toolbars The buttons on each toolbar can be customized to suit your individual needs 1 Click the arrow found at the end of a toolbar 2 Select which toolbar you wish to customize 3 Select which buttons you wish to appear or not appear on the toolbar W Dynojet Power Vision WinP untitled pvt File Edit PowerVision Compare Setup View Help e H Ff g X o Open Save Cut Copy Paste Print About Add Subtract Divide Multiply Set Value eo is i E 2 x mi re r Info GetTune SendTune Get ECM GetLog Load Close Active File Compare Delta Compare Compare File Tune Items Tune Info untitled prt Compare H E Airflow nos Customize c h CJE Engine Displacement REM mae send Tune z aE ae aik Cy IAC warmup Steps mam r Get ECM Data S4C JH Idle REM ae i E CJE Throttle Blade Control I i a Get Llog CJE Throttle Blade Control Al a i i mie WE Front cyl Reset Toolbar FIE VE Rear cyl 1500 Mm fil 3 38 eyes WinPV User Guid
51. atuaetastes toes ege chee eee take ce ee en 3 16 To Cut Copy Paste Selected Values 20005 3 16 To Smooth Selected Values 0 00 eee ee es 3 16 To Interpolate Selected Values a eee ee 3 16 To Interpolate Selected Horizontal Values 3 16 To Interpolate Selected Vertical Values 005 3 16 PowerVision Menu 0 0 a a 3 17 To View the PowerVision Information 2 0005 3 17 To Get a Tune from the Power Vision 00000 3 17 To Send a Tune to the Power Vision 0002s eae 3 18 To Get a Log from the Power Vision 0 00004 e 3 19 To Update the Tune Using the Power Vision 3 21 To Get ECM Data from the Power Vision 0085 3 21 To Send the Original Tune to the Power Vision 3 23 To Send a Stock File to the Power Vision 3 24 TO Exit PC Link Mod acactcaaeiaddbetvadetecaeeae ans 3 24 Compare Menu aa es 3 25 To Load a Compare File saana a anana ee 3 25 To Close the Compare File 2 000 ee ee es 3 25 To View the Active File 0 0 0 eee ee es 3 25 To View the Compare File 2 000 eee eee ees 3 26 TO VIEW Della 4444 4 e ce4554 44008 35 Orear EOS 3 26 To Choose Cell Colors oana ee 3 26 To Show Only Differences 0 0 eee ee es 3 27 To Show Delta As Percent 2 000 ee ee 3 27 To Create Difference Report 2 00 eee ee es 3 27 Setup Menu 1
52. ber plug installed Diagnostic connector is located behind the right front frame cover This connector is light grey in color with a black rubber plug installed Note Tools required to access Diagnostic connector is located behind the right hand side cover This connector is light grey in color with a black rubber plug installed Note Requires removing the right side saddle bag Diagnostic connector is located behind the left hand side cover This connector is light grey in color with a black rubber plug installed Note Requires removing the left side saddle bag 2 9 WinPV User Guide x CHAPTER 2 Y Installing the Power Vision on the Motorcycle Note Many models use the same style connector for accessories The Power Vision must be connected to the diagnostic port 2 Route the PowerVision cable away from any moving or hot parts Dynojet recommends using zip ties to secure the cable to existing non moving components 2 10 Degen ee gee WinPV User Guide GETTING STARTED Sx Installing the Power Vision on the Motorcycle 3 The PowerVision module may be mounted to the bike s handlebars using Techmount hardware Note The Power Vision does not need to remain on the bike In this example the Power Vision module is mounted to a 2008 Night Rod using the Techmount bracket For more information on available mounting accessories visit www techmounts com 2 11 Version
53. ck OK to accept the changes Pro User Level will expose additional tune items and parameters which can affect the operating condition of the vehicle Property Value Units Metric User Level Pro E Stock Files Folder Tune Files Folder Pra Value Files Folder C s User Level Sets the user level cancel 3 28 WinPV User Guide WORKING WITH WINPV ke WinPV Menus h 4 To create the default location where the Power Vision stock files stk are stored on your computer 4a Create a Stock Files directory in C Program Files Power Vision 4b Click to browse to the Stock Files folder you created 4c Click OK to save the location Options SS Property Value Units Metric User Level Pro Stock Files Folder C Program Files Power VisionStock Files Tune Files Folder C Program Files Power Vision Tune Files Value Files Folder C Program Files Power Vision alue Files Stock Files Folder This is the default location where Power Vision stock tunes stk are stored on your computer OK Cancel Browse forFoller aE oof Gutlook Express H Power Commander 5 EHG Power vision H E QuickTime H Reference Assemblies oo Remove WebWorks ae Rawin Ma 3 29 Version 7 WinPV User Guide aN CHAPTER 3 WinPV Menus 5 To create the default location where the Power Vision tune files pvt are stored on your 3 30 computer 5a Create a Tune Files directory in C Program Files Powe
54. ctive will reset all learned values PowerVision Application AutoTune Session 006 Tune My1 764E LogTuned Smoothed Mode Dual Wideband Learned Spark 0 cells avg O max 0 Learned VE 1 20 cells avg 1 max 16 ee a i Disable AT ppa Reset Learned s Settings Datalog J BACK Ss 2 Touch Continue Note Changing the settings while AutoTune is active will reset all learned values PowerVisio n Application WARNING Entering SETTINGS while Autotune is active will RESET ALL LEARNED VALUES when you press Continue Continue i Cancel Sees A Version 7 WinPV User Guide N CHAPTER 4 SE Power Vision Menus 3 Touch a setting to edit In this example we will use Max Spark Learn To see a list of all settings and descriptions refer to AutoTune Settings 4 Touch Select to continue with the selected setting Or Touch Exit to abort the process PowerVision Application Select Setting to EDIT Reset all to DEFAULTS Min Hit Count 5 ticks US Min VE Learn 0 01 Percent Max VE Learn 15 00 Percent Min Spark Learn 1 00 Degrees Max Spark Learn 0 00 Degrees Min WB Lambda 0 68 Lambda Max WB Lambda 1 22 Lambda x Min Engine Temp 75 0 Deqc Exit i Select 5 A description of the setting will appear Touch Continue to edit the selected setting To see a list of all settings and descriptions refer to AutoTune Settings PowerVision Applicatio
55. e WORKING WITH WINPV Tune Items s Tune Items Tune Items shows the available values parameters and tables All of these values affect the way the vehicle performs Tune Items fall into one of the three categories e Switch values that are either on off yes no true false 0 1 etc Tune Items E Knock Control E E Tune Info untitled pvt Sy Editor Settings loa Airflow H ag Fuel H ag Gear E Limits amp Switches ef RPM Limit eam C1 FITMS RA EE knock Control A Adaptive Control CJE PE Enable RPM CJA Active Exhaust see si Active Intake bese E Active Compression Relee Oh OFF RowLabel C Heated O2 Sensors 7 2 PE Disable RPM Spark e Scalar values that are a single number a Lambda AFR Stoich Value untitled pyvt Tune tems H Tune Info e Editor Settings C ai Display as Lambda fT ef Lambda AFR Stoich value H Airflow H Fuel H a Gear H E Limits amp Switches 9 Spark AFR RowLabel 3 39 Version 7 WinPV User Guide A CHAPTER 3 em T Tune Items e Tables values that are displayed in multiple columns and or rows Tune Items H Tune Info Editor Settings Airflow Dai Engine Displacement os Q IAC Warmup Steps DAENS CJE Throttle Blade Control RPM 16 1432 i424 a Han E Throttle Blade Control AN C E VE Rear Cyl 48 1136 IE Ide RPM Adder a4 m Pea ee ao
56. e for F Power Vision fi Click Finish to close the wizard Back Eancel 8 Continue with Checking the WinPV Update Client 2 3 Version 7 WinPV User Guide CHAPTER 2 f Power Vision Driver Installation Windows Vista and Windows 7 Driver Installation Power Vision Device Drivers will be installed during software installation A Windows Security warning will pop up during this process Click I nstall to continue f 2 1 Windows Securit Would you like to install this device software Name Dynojet Research Ports COM amp LPT a Publisher Dynojet Research Inc Ol Always trust software from Dynojet Research Inc Don t Install g You should only install driver software from publishers you trust How can I decide which device software is safe to install Note During the installation a notice on the bottom of your screen will appear letting you know the status of the device driver installation progress z Installing device driver software Click here for status me o 2 4 WinPV User Guide GETTING STARTED to Checking the WinPV Update Client Checking the WinPV Update Client The PV Update Client automatically checks for any applicable updates The latest versions of the Firmware Software Tune Database and any Critical Updates will be displayed in the Latest Version column Your currently installed versions will be displayed in the Installed Version column Note P
57. e is correct for your model of motorcycle Refer to To Edit AutoTune Settings 2 Touch Enable AT PowerVision Application AutoTune Sessnmn 007 AutoTune NOT Active Enable AT Export r Disable AT amp Learned ff Learned p gt i Settings B Data log E N N Version 7 WinPV User Guide N CHAPTER 4 Ir Power Vision Menus 3 Touch a tune file to load 4 Touch Select to continue with the selected tune file Or Touch Cancel to abort the process and return to the program vehicle menu PowerVision Application Step 1 Select TUNE to Autotune Slot 1 Myl 764E LogTuned Smoo Slot 2 Autotune Results 0005 0 Slot 3 Autotune Results 0005 1 Slot 4 Autotune Results 0003 4 Slot 5 Autotune Results 0002 0 Slot 6 Autotune Results 0002 1 i Select Cancel 4 18 WinPV User Guide WORKING WITH POWER VISION Lee Power Vision Menus 5 Select the AutoTune mode Touch Basic to use the OEM Narrowband O2 sensor tuning to a temporary stoich 14 6 Air Fuel Ratio Or Touch Pro to use Dynojet Widebands for tuning using a wider Air Fuel Ratio range Note f you do not have Wideband O2 sensors installed ie those included in the Dynojet AutoTune kit select Basic The two different methods of AutoTune yield similar results in most areas but Dynojet recommends using AutoTune Pro for best results in all operating conditions that you would experience while riding Or Touch Cancel to abort
58. e to Edit or Flash this tune to the ECM Flash Edit Exit Note You can edit any tune that s loaded in the Tune Manager prior to flashing your ECM The Power Vision allows you to make basic adjustments to your tunes directly on the device without using a computer In order to gain full access to your tune files you ll need to download them from the Power Vision to WinPV our custom tuning software WinPV User Guide WORKING WITH WINPV WinPV Software is a user friendly interface which will allow you to easily develop new fuel and ignition maps record and download log files and increase performance with the click of a button This section is divided into the following categories WinPV User Interface page 3 2 WinPV Menus page 3 3 WinPV Toolbar page 3 34 Tune Items page 3 39 Table page 3 53 Status Bar page 3 54 WinPV User Guide 3 1 E CHAPTER 3 WinPV User Interface WinPV User Interface WinPV is designed to be user friendly and intuitive Once you understand the basic layout it will be easy to obtain information and navigate the software efficiently The main elements of the WinPV User Interface are WinPV Menus Tune Items WinPV Toolbar Table menu bar AP Lat ene oe ae es WinP toolbar L ute O m o m m m tune items je HE ahma CS Trenttie Table Transition 1 Eg Dries Dy ire Spaad Lire E D miot H Fua aakit table HD k TeV tt mae at ech
59. eina ren ea Sle ea a ca Spe ee ae 4 50 ORC AG ECM lt ois acs ge 8 oa he A ee aE Se ato te Win ee Oe 4 51 To Restore Original Tune 2 1 ee 4 52 To Return to the Power Vision Main Menu 055 4 52 Version 7 WinPV User Guide a TABLE OF CONTENTS WinPV User Guide Settings Menu aaaea 4 53 To Select the UNUS e ciescewcedeaneeacae esd a 4 53 To Change the Brightness 0 000 eee ee ees 4 53 To Entera COde 666 cess ce eee cee eee ae eee eee 4 55 To Calibrate the Touch Screen 0 000 eee ee 4 55 To Flip the Power Vision Screen 2 000000 eee ees 4 55 To Return to the Power Vision Main Menu 055 4 55 Device Info Menu es 4 56 To View Information About the Power Vision 4 56 Dealer Info Menu 0 0 000 ee 4 57 To View Information About the Dealer 4 57 Understanding AutoTune 0 0 cee ee 4 58 AutoTune BaSIC aoaaa a es 4 59 AULOTUNE PIO a ean baad a weed ew eee ewe RED eo 4 59 AutoTune Wideband O2 Sensor Installation Options 4 60 Changes Made During AutoTune 0 0000 a 4 60 AutoTune Notes and TipS e eee 4 61 Index oaoa bee Index i WELCOME TO DYNOJET WINPV SOFTWARE The Software Engineers at Dynojet understand your need to attain the maximum performance from the Harley Davidson motorcycles you evaluate and tune For this reason they have developed a user friendly interface which will allow you to
60. elected Dynojet tune file Or Touch Cancel to abort the process and return to the load tune screen Select Dynojet Tune to Load 07T096000101 07T096000301 07T096002301 07TO096002302 07T096002304 07T096002305 07T096002306 07T096002307 07T096002308 6 Verify the Tune information If the Tune information is correct touch Continue 0 7TOS600e2306 pvt Notes Strategy 44 ECU 34245 111 Year 2011 Family TOURING SE Air Cleaner Rush True Duals 2 baffels Economy 91 93 Octane Continue s Cancel 4 5 Version 7 WinPV User Guide x CHAPTER 4 E i Power Vision Menus 7 Touch a slot to save the selected tune file Note f there is any data in the selected slot it will be overwritten 8 Touch Select to continue with the selected slot Or Touch Cancel to abort the process and return to the tune manager 9 Touch OK to continue A copy of the Dynojet tune will be saved Or Touch Cancel to abort the process and return to the tune manager Select Custom Tune to SAVE to Slot 1 Stock Read Slot 2 Tab Slipon_KandN Filter Slot 3 Empty Slot 4 Empty Slot 5 0O7T096002412 Slot 6 07T096002301 Select Cancel The tune is now ready 4 6 WinPV User Guide WORKING WITH POWER VISION T Power Vision Menus 10 Touch Flash to send the file to the ECM Or Touch Edit to edit the tune file on the Power Vision Or Touch Exit to exit the screen without any changes Tune Ready
61. enable visual alarm AutoTune Basic and Pro calculates and stores fuel trims to optimize fuel curve Check and clear diagnostic codes Reset adaptive fuel trims and idle offset OOS WinPV User Guide 4 1 N CHAPTER 4 F Power Vision Menus Power Vision Menus Maalin Program Vehicle Menu To Load a Dynojet Pre Configured Tune File To Load a Custom Tune File To Load a Copy of Original Tune File To Load a Copy of Current Tune File To Edit a Tune File To Check the ECM Status To Enable AutoTune To Start an AutoTune Session To Export a Learned Tune To Load a Custom Tune File To Edit AutoTune Settings To Configure Quick Tune 4 2 WinPV User Guide ee le m i Fz i LA 4 p F rs j han E oad Hetta ti VEHICLE TOOLS pa DEVICE INFO Datalog Menu To View Gauges To Create Gauge Limits and Visual Warnings To Playback a Log To View Signals To Reset Trip Economy A To Reset Trip Economy B To Create a Log with Power Vision To Return to the Power Vision Main Menu Vehicle Tools Menu To View Vehicle Info To View Stored DTC s To Reset Trims To Read ECM To Restore Original Tune To Return to the Power Vision Main Menu Settings Menu To Select the Units To Change the Brightness To Enter a Code To Calibrate the Touch Screen To Flip the Power Vision Screen To Return to the Power Vision Main Menu Device Info Menu To View Information About the Power Visio
62. ends on Power Vision Unit Setting The maximum engine temperature where learning is allowed entered in Degrees Celsius or Fahrenheit depends on Power Vision Unit Setting The minimum engine speed where learning is allowed in RPM The maximum engine speed where learning is allowed in RPM The minimum MAP value where learning is allowed This is used to filter out deceleration events The maximum MAP value where learning is allowed This is usually marked as not used and set to something high like 120 KPA The following table lists the default AutoTune settings for different vehicles Big Twin including Softail Dyna and Sportster setting Touring models V Rod models models Min Hit Count 5 ticks 5 ticks 5 ticks Min VE Learn 0 01 percent 0 01 percent 0 01 percent Max VE Learn 15 00 percent 15 00 percent 15 00 percent Min Spark Learn 1 00 degrees 1 00 degrees 1 00 degrees Max Spark Learn 0 00 degrees 0 00 degrees 0 00 degrees Min WB Lambda 0 68 lambda 0 68 lambda 0 68 lambda Max WB Lambda 1 22 lambda 1 22 lambda 1 22 lambda Min Engine Temp 167 F 160 F 280 F Max Engine Temp 300 F 230 F 410 F Min RPM 900 RPM 1000 RPM 1000 RPM Max RPM 6000 RPM 10000 RPM 7000 RPM Min MAP 20 KPA 20 KPA 20 KPA Max MAP 120 KPA 120 KPA 120 KPA Version 7 WinPV User Guide CHAPTER 4 yr Power Vision Menus To Configure Quick Tune Quick Tune allows you to alter the last tune flashed to the vehicle s ECM without requiring a computer
63. erent in the selected file 1 Click the box next to the table you would like to save Tune tems H Tune Info L1 a Description Ff Calibration 1D Fg Editor Settings BE Airflow iee QJ f Engine Displacement 08 IAC Warmup Steps J8 Idle RPM FA Throttle Blade Control 2 Lgi Throttle Blade Control 4ll 2 Select File gt Save Selected Values Append 3 Browse to your Value File folder and select the value file you wish to append values to 4 Click Open Select P Yalue File to append values to RES Look in 9 Value Files O2 oa i My Recent Documents Desktop ne My Documents SE My Computer Ki File name ve Front pvv X e ET Files of type Py Value File pvv Cancel Places I Open as read only 3 11 Version 7 WinPV User Guide CHAPTER 3 WinPV Menus 5 Enter a name for the new value file and click Save Save P alue File As Save in O Value Files Co fa i gt fi Pe EFront py My Recent Documents Desktop S My Documents e PI My Computer Aa My Network File name VEFront ppend pvv gt Places Save as type Harley P Value File pvv 7 Cancel 6 To load the file you created refer to To Load Selected Values To Load All Values Load All Values is used for loading in all of the changes in a Value File If the Value File directory does not exist or if you haven t already created the Value File directory yo
64. es ef Tune Files Value Files ES QuickTime H Reference Assemblies of Remove WebWorks ee Bevin To Apply the License Apply License is used to enable features in the Power Vision and WinPV software that have been provided to you by Dynojet Select Setup gt Apply License 3 31 Version 7 WinPV User Guide xy CHAPTER 3 F amp WinPV Menus View Menu To View the Standard Toolbar Select View gt Standard Toolbar or right click to turn the toolbar on and off For more information about the Standard Toolbar refer to Standard Toolbar T Als d Ff amp Open Save Cut Copy Paste Print About To View the Cell Math Toolbar Select View gt Cell Math Toolbar or right click to turn the toolbar on and off For more information about the Cell Math Toolbar refer to Cell Math Toolbar ae K wi A Add Subtract Divide Multiply Set Percent To View the PowerVision Toolbar Select View gt PV Toolbar or right click to turn the toolbar on and off For more information about the PV Toolbar refer to PowerVision Toolbar Qe 4 i rd Info GetTune SendTune GetECM Get Llog Data To View the Compare Toolbar Select View gt Compare Toolbar or right click to turn the toolbar on and off For more information about the Compare Toolbar refer to Compare Toolbar gs rm tr fal Table Range r gt Load Close Active File Compare Delta Erci Compare Compare File gee To Reset the User Interface Selec
65. es will be reduced towards zero This gradually clears out the learned knock value to adapt changes in conditions Available in pro user level only This is the spark to run when the throttle is closed This table can be modified to allow the engine to run at different spark values when the throttle is closed This table will replace the Spark advance table and any temperature corrections when the throttle is closed 3 51 WinPV User Guide re CHAPTER 3 a Tune Items 3 52 tune item Closed Throttle Spark Rear Spark Adjust By Air Temp Spark Adjust By Engine Temp Spark Adjust By Head Temp WinPV User Guide description This is the spark to run when the throttle is closed This table can be modified to allow the engine to run at different spark values when the throttle is closed This table will replace the Spark advance table and any temperature corrections when the throttle is closed Spark gets adjusted by this value to compensate for air temperature Spark gets adjusted by this value to compensate for engine temperature Spark gets adjusted by this value to compensate for head temperature WORKING WITH WINPV Table The Table displays the item chosen in Tune Items The table is also displayed as a 3 D representation below the table 1 Click one cell to select it 2 Click and hold the mouse button while dragging to select multiple cells Selected cells will appear with cross hairs in the graphical
66. ettings e Knock control on Sportsters is not possible the ECM does not support this feature and AutoTune does not support automated spark adjustment based on knock activity e In Pro mode you can tune fuel and spark simultaneously however Dynojet recommends to address fuel first and then focus on spark To do this after you ve completed tuning the fuel via adjustments to your VE tables and flashed the corrected tune file to your ECM you can then start a new AutoTune session that s focused on spark corrections In the settings area of AutoTune you can set Max VE Learn to 0 and Max Spark Learn to 10 This will disable AutoTune s ability to change fuel but allow it to monitor record and eventually correct spark advance based on knock activity 4 61 Version 7 WinPV User Guide A about window 3 33 acceleration enrichment 3 47 acceleration enrichment multiplier 3 48 active compression release 3 50 active exhaust 3 50 active file 3 25 3 37 active intake 3 50 adaptive control 3 50 adaptive control enable temp 3 45 adaptive control maximum temp 3 45 adaptive control maximum temp hysteresis 3 46 adaptive control minimum temp hysteresis 3 46 adaptive knock retard 3 51 add 3 36 air flow charge dilution effect 3 42 charge dilution effect front 3 42 charge dilution effect rear 3 42 DBW throttle position limit 3 44 drive by wire speed limit vs gear 3 44 drive by wire throttle limit vs gear 3 42 engine displacement 3 42 IAC warm up
67. fo 5S N 0000000000000000 Tuning Not Enabled Firmware PowerVision 0 0 25 345 Interface Built Sep 22 2010 14 50 43 f 4 56 WinPV User Guide Dealer Info Menu To View Information About the Dealer Dealer Info displays dealer information Touch Dealer I nfo Dealer Info Empty oo Version 7 WORKING WITH POWER VISION Ta Power Vision Menus WinPV User Guide Te 4 57 ay CHAPTER 4 j Understanding AutoTune Understanding AutoTune The Power Vision supports a process to correct your VE tables and AFR based on your OEM narrowband O2 sensors Basic Method or with wideband O2 sensors from the Dynojet AutoTune Kit Pro Method In addition AutoTune can use the ECM s ion sensing knock control strategy in order to remove timing adjust spark advance from areas of your calibration where knock was present Refer to AutoTune Notes and Tips There is no longer a need to go through the cumbersome process of exporting value files logging processing values and logs in Log Tuner etc Power Vision automatically sets up the tune logs the correct channels and applies a correction to your tune Leave the laptop at home you now have a full time professional tuning expert inside your Power Vision Most modern EFI systems employ closed loop feedback for fuel control These systems are often based around narrowband O2 sensors that provide feedback to the ECM in regards to how rich or lean the vehicle is
68. he Tune Manager This will be the tune that contains the AutoTune corrections Note A tune saved in the Tune Manager will never have those values that are set up by the AutoTune process included within them only the values that were learned during the AutoTune process Touch Select to continue with the selected tune file Or Touch Cancel to abort the process and return to the custom tune screen PowerVision Application Step 1 Select TUNE to Autotune Slot 1 My1 764E LogTuned Smoa Slot 2 Autotune Results 0005 0 Slot 3 Autotune Results 0005 1 Slot 4 Autotune Results 0003 4 Slot 5 Autotune Results 0002 0 Slot 6 Autotune Results 0002 1 i Select Cancel Touch Flash to send the file to the ECM Note Do not turn off the key while the Power Vision is flashing the ECM Once the process is complete you will be prompted to turn the key off and wait ten seconds Touch OK Turn the ignition key off and wait ten seconds Turn the ignition key back on You can ride the bike with the changes from the AutoTune process or you can start a new tuning session to continue to refine your custom tune WinPV User Guide WORKING WITH POWER VISION 5 Power Vision Menus ot To Edit AutoTune Settings For more information about AutoTune refer to Understanding AutoTune Use the following steps to edit the AutoTune settings 1 Touch Program Vehicle gt AutoTune gt Settings Note Changing the settings while AutoTune is a
69. he box next to the tune items you would like to import Or Click Mark All to select all the tune items in the list Or Click Mark Selected to place a check mark next to the tune items you have selected Or Click Clear Selected to clear all of the check boxes 6 Click OK to accept the changes Or Click Cancel to close the window Mark tune items to import with checkboxes then press OK to import them YE Front Cyl Table doesn t change and will match desired More info here Clear All Mark All Mark Selected Clear Selected H E Cancel 7 Click OK to complete the import Complete Ex Imported 1 1 tune items To Exit the WinPV Software Select File gt Exit to exit the WinPV software 3 15 Version 7 WinPV User Guide ay CHAPTER 3 se WinPV Menus Edit Menu To Undo Select Edit gt Undo to take a step back and undo the last changes made to the tune To Redo Select Edit gt Redo to reverse an action you undid To Cut Copy Paste Selected Values 1 Select the desired values 2 Select Edit gt Cut to cut the selected values 3 Select Edit gt Copy to copy the selected values 4 Select Edit gt Paste to paste the copied values To Smooth Selected Values Smoothing is a process that removes the sharp peaks and troughs from a data series or Surface map Smoothing is designed to smooth data after modifications have been made 1 Select the desired values You must select at least two cells 2 Select
70. he data correct the tune and then re flash the corrected tune into the ECM Neither AutoTune Basic nor AutoTune Pro requires that you interface with a computer Power Vision sets up the AutoTune parameters monitors and logs the data and then corrects the tune to ensure that the final tune has optimum values in the VE table s AutoTune Pro Utilizing a Dynojet AutoTune wideband control module Power Vision can provide a complete refined and powerful tune The AutoTune module uses wideband O2 sensors in order to measure the actual AFR in the exhaust these sensors can accurately sample AFR values from 10 0 1 to 18 0 1 vs 14 3 15 2 from narrow band sensors Like AutoTune Basic the entire process will correct the error from what is commanded in the ECM defined as the target AFR and the AFR that s actually measured in the exhaust The AutoTune Pro method allows the target AFR table to include AFR values that are ideal for all operating conditions resulting in the best data for high load high RPM operating ranges as well as idle light load and cruise conditions Utilizing the AutoTune Pro AFR data and other data from the H D OEM data bus the Power Vision can automatically fix the deviation between the target AFR and actual AFR by adjusting the VE tables instead of storing the changes in an Adaptive fuel table The data is learned in real time but processing the data and adjusting the tune Is done in an offline State key on engine off
71. ill be disabled at RPMs less than this setting Available in pro user level only For closed Loop capable calibration set this to off to disable closed loop control description Power Enrichment mode is active at higher RPMs and when the throttle position is greater than 95 percent This table is desired spark over time The purpose of PE mode is to operate the engine at maximum torque AFR and spark values for a Short time then adjust to more conservative values to reduce engine temperature Available in pro user level only There are two spark tables one for each cylinder This is because the rear cylinder runs hotter than the front and therefore has different timing requirements The X axis is KPA the Y Axis is RPM Set these values to the spark advance you would like the bike to operate at Available in pro user level only There are two spark tables one for each cylinder This is because the rear cylinder runs hotter than the front and therefore has different timing requirements The X axis is KPA the Y Axis is RPM Set these values to the spark advance you would like the bike to operate at Available in pro user level only This is the maximum amount of knock retard the ECM will allow Available in pro user level only The Delphi ECM utilizes Adaptive Spark Control based on information received from the knock detection system This system learns retard values to apply when knock is detected At each key on the remembered valu
72. ill save all of the value files in the open tune file into a Value File for later use If the Value File directory does not exist or if you haven t already created the Value File directory you will need to create a Value File directory in C Program Files Power Vision Once the Value File directory is created you must map this folder in Setup Options Refer to To Setup the Options 1 Make sure you have a tune loaded You must have a tune loaded before saving values 2 Select File gt Save All Values 3 Enter a name for your value file 4 Click Save Save P alue File As Save in Value Files ea My Recent Documents Desktop My Documents wn SE My Computer im Y My Network File name flename pvv gt Places Save as type Harley PY Value File pvv 7 Cancel 3 9 Version 7 WinPV User Guide Y CHAPTER 3 r WinPV Menus To Save Selected Values Value Files are one or more tables that are selected in WinPV Save Selected Values will save only the parameters selected into a Value File for later use If the Value File directory does not exist or if you haven t already created the Value File directory you will need to create a Value File directory in C Program Files Power Vision Once the Value File directory is created you must map this folder in Setup Options Refer to To Setup the Options 1 Click the box next to the table or tables you would like to save Tune Items H
73. in a closed loop AFR of 14 68 increasing the value will give a richer mixture and decreasing the value will give a leaner mixture Available in pro user level only The closed loop bias table is used to adjust the closed loop AFR Setting the value in this table to 450 mV will result in a closed loop AFR of 14 68 increasing the value will give a richer mixture and decreasing the value will give a leaner mixture Available in pro user level only This is the amount that the O2 sensors will control to above or below Stoich 14 68 A F ration for gasoline Setting the value in this table to 450 mV will result in a closed loop AFR of 14 68 increasing the value will give a richer mixture and decreasing the value will give a leaner mixture This is the Min and Max range of Lambda the ECM uses when operating in closed loop A value above 1 01 will allow the ECM to learn a leaner rage for closed loop A value lower than 98 will allow the ECM to operate at a richer range for closed loop description This is the ratio the bike has in it from the factory This must Gear Ratios Version 7 be changed to the new ratio when changing tire size This value is Pulses Per 1 125th KM This represents the gear ratios of the transmission 3 49 WinPV User Guide a CHAPTER 3 x Tune Items Limits and Switches 3 50 tune item RPM Limit EITMS Knock Control Adaptive Control PE Enable RPM Active Exhaust Active Intake
74. isable the oxygen sensor heater 3d Click the box to enable disable Active Exhaust 3e Using the up or down arrows increase or decrease the Vehicle Speed Sensor VSS calibration This is used to calibrate the speedometer PowerVision Application Active Config Config General Config rweaks ACR e Active Intake am Heated O2 FA Active Exhaust VSS 2078 Pulses KM yY A i faul Continue 4 35 Version 7 WinPV User Guide CHAPTER 4 Power Vision Menus 4 Touch Tweaks Use the Tweaks tab to set Adaptive Closed Loop AutoTune Mode Knock Control and EITMS Engine Idle Temperature Management System 4 36 4a 4b 4c 4d 4e WinPV User Guide Click the box to enable disable Adaptive Click the box to enable disable Knock Control Click the box to enable disable Closed Loop Click the box to enable disable EITMS Engine Idle Temperature Management System Using the up or down arrows select the AutoTune Mode mocne Adaptive a Knock Control C4 Closed Loop al EITMS Auto Tune Mode WORKING WITH POWER VISION ks Power Vision Menus hs 5 Touch Fuel Use the Fuel tab to set the fuel adjustment The fuel adjustment range is 25 to 25 offset of the base fuel map 5a Using the up or down arrows set any of the six ranges of fuel adjustment Refer to the Fuel Spark and VE Ranges Table Global Continue 6 Touch Spark Use the Spark tab to set the spark ad
75. it 100 H Warning Ok Cancel 4 39 Version 7 WinPV User Guide aT CHAPTER 4 JH Power Vision Menus 5 From the device list choose Harley or DJ Wideband2 6 Touch Select to confirm your choice Or Touch Cancel to return to the Set Gauge Properties screen 7 From the Signal list assign a signal 8 Touch OK to confirm your selection Or Touch Cancel to return to the Set Gauge Properties screen Assign Signal Accel Enrichment Barometer Battery Voltage Brake Clutch State Coast Cruise Enable Cruise Engauge To edit additional gauge properties refer to To Create Gauge Limits and Visual Warnings 9 Touch OK to confirm the gauge properties 10 Touch Exit to exit the Datalog menu 11 Touch Back to return to the Power Vision main menu 4 40 OOC 3 WinPV User Guide WORKING WITH POWER VISION he Power Vision Menus To Create Gauge Limits and Visual Warnings 1 Touch Datalog gt Gauges 2 Using the left or right arrows at the bottom of the screen select your desired gauge template 3 Touch None or the current gauge label to edit the gauge properties L Limit 0 L Warning H Limit 100 H Warning 4 4 Version 7 WinPV User Guide fy CHAPTER 4 ir Power Vision Menus 5 From the device list choose Harley or DJ Wideband2 6 Touch Select to confirm your choice Or Touch Cancel to return to the Set Gauge Properties screen 7 From the Signal list assign a signal 8 T
76. itional steps are added to the IAC Built motors may requiring adding steps to this The Engine Idle Temperature Management System EI TMS Off Temperature reduces heat buildup during prolonged idling times and controls heat buildup in two stages Mode 1 AFR Enrichment is activated when the engine temperature exceeds 142 C Sportsters 230 C and the engine RPM is less than 1200 RPM Mode 2 Skip Fire Big Twins only activates if Mode 1 is active and the engine temperature exceeds 155 C and the vehicle speed is less than 1 2 KPH Note Sportster temperatures are much higher due to the location of the temperature sensor and only uses EITMS Mode 1 AFR Enrichment When Mode 2 Skip Fire is active additional steps are added to the IAC Built motors may requiring adding steps to this Knock Control will be activated at temperatures greater than this setting Set to a high value like 310 C to disable knock control all the time Knock Control will be de activated at temperatures lower than this setting Set this to Knock Control Minimum Temperature minus 2 C Adaptive Control will be enabled at temperatures greater than this setting Available in pro user level only Adaptive Control will be disabled at temperatures higher than this setting Set to a high value like 310 C to remove the hot limit Also set Adaptive Control Maximum Temperature Hysteresis to be 5 C below this WinPV User Guide 3 45 FJ 3 46
77. justment The spark adjustment range is 5 to 5 degrees from the base timing advance map 6a Using the up or down arrows set any of the six ranges of spark adjustment Refer to the Fuel Spark and VE Ranges Table PowerVision Application Global 0 Jefaul n Continue S S Version 7 WinPV User Guide N CHAPTER 4 F Power Vision Menus 7 Touch VE Use the VE Volumetric Efficiency tab to set the VE adjustment The VE adjustment range is 25 to 25 VE units offset from the base VE table 7a Using the up or down arrows set any of the six ranges of VE adjustment Refer to the Fuel Spark and VE Ranges Table 8 Touch Continue to apply your changes Continue Fuel Spark and VE Ranges Table The following table is an example of where the fuel spark and VE ranges are Spark Advance Front Cyl 1 1 KGM YN788NM pyt RPM 15 70 80 90 100 10 00 10 00 Pioo Tom fioo Hugging 10 00 10 00 ae mAN ii z bret LA 00 t gt gt ven bh gt ETI oO P y G j ti 0 00 15 00 15 00 15 00 15 00 15 00 4 38 mma WinPV User Guide WORKING WITH POWER VISION he Power Vision Menus Datalog Menu To View Gauges 1 Touch Datalog gt Gauges 2 Using the left or right arrows at the bottom of the screen select your desired gauge template 3 Touch None or the current gauge label to edit the gauge properties Signal L Lirnit 0 L Warning H Lim
78. lease read the Update Messages on the top of the Update Client window for any critical updates and follow any directions given there first Using the USB cable connect the Dynojet Power Vision to your computer Click Start on the Windows task bar and click All Programs Select PowerVision gt PV Update Client Click Check For Updates Select the desired update to install Click Download amp Install Selected Updates au RWN Power Yision Update Client x Server Update Messages Atbention All PY users should update to the lakest WinPY software 1 0 20 Irmporkant Any PY with a Batch Number lower than 110201 see label on the back the PY MUST install Critical System Upgrade 1 0 1 The Critical System Upgrade will ONLY be available via the Update Client once vou install the latest software noted above ef Installed version Latest Version PY Software Update Utility WinPY etc 1 0 22 x32 1 0 22 32 bit PY Critical System Upgrade 1 0 1 1 0 1 1 0 1 1 0 1 1 0 1 PY Firmware 1 0 3 723 1 0 3 723 PY Tune Database 0 0 9 2 0 0 02 Je ih Rap pde Download amp Install Update From Exit Selected Updates Local File ver 1 0 4 0 7 As the firmware and tune database downloads are completed click OK to complete Package Installed OK fx Installing P _FIRMWARE 0 0 36 548 pvu Updated 4 things 0 errors O 8 As the software and update client downloads are completed click OK to begin the software download N
79. losed loop bias front 3 49 closed loop bias rear 3 49 closed loop lambda range 3 49 closed loop minimum temp 3 46 closed loop minimum temp hysteresis 3 46 closed throttle spark front 3 51 closed throttle spark rear 3 52 code 4 55 compare file 3 26 3 37 visual identifiers 3 41 compare high low 3 26 compare menu 3 25 active file 3 25 cell colors 3 26 close compare 3 25 compare file 3 26 create difference report 3 27 delta 3 26 load compare 3 25 Show delta as percent 3 27 Show only differences 3 27 compare toolbar 3 32 3 37 active file 3 37 cell colors 3 37 close compare 3 37 compare file 3 37 customizing 3 38 delta 3 37 load compare 3 37 config quick tune 4 35 contact email 1 1 phone 1 1 conventions 1 2 copy 3 34 copy cells 3 16 copy of current tune file 4 12 copy of original tune file 4 9 cranking fuel 3 47 create a log 4 47 create difference report 3 27 custom tune file 4 8 customizing the toolbars 3 38 cut 3 34 D datalog 4 21 datalog menu create a log 4 47 gauge limits 4 41 gauges 4 39 Index ii WinPV User Guide playback a log 4 45 reset trip economy A 4 46 reset trip economy B 4 47 Signals 4 46 visual warnings 4 41 datalogger modes 4 24 datalogger operating conditions 4 23 DBW throttle position limit 3 44 dealer info 4 57 dealer info menu 4 57 dealer info 4 57 deceleration enleanment 3 47 deceleration enrichment multiplier 3 48 delta 3 26 3 37 description 3 42 device info 4 56 device info me
80. ly spark tables will be modified PowerYision Application ect Slot to Save Autotune Resul Slot 1 My1 764E LogTuned Smoca Slot 2 Autotune Results 0005 0 Slot 3 Autotune Results 0005 1 Slot 4 Autotune Results 0003 4 Slot 5 Autotune Results 0002 0 Slot 6 Autotune Results 0002 1 s Select r Cancel It is time to flash the ECM with the new tune you just saved to the tune manager Once the new tune has been flashed to the ECM you can ride the bike to feel the results or engage in another tuning session to continue to refine your custom tune If you do not flash a tune to the ECM you will still be running on a tune set up by the AutoTune feature WinPV User Guide WORKING WITH POWER VISION Sx Power Vision Menus 7 Exit to the Main Menu and load your custom tune Refer to To Load a Custom Tune File PowerVision Application AutoTune Sessmon 007 AutoTune NOT Active i Learned Reset Learned p Enable AT Disable AT i 4 Export W y w CEA i Settings E T Data log E To Load a Custom Tune File For more information about AutoTune refer to Understanding AutoTune 1 Turn the ignition key to the On position 2 Verify the Run Off switch is in the Run position Do not start the engine 3 Touch Program Vehicle gt Load Tune gt Custom Tune N A y A Version 7 WinPV User Guide i 4 ee 4 28 x CHAPTER 4 p Power Vision Menus Touch the last tune you saved to t
81. m tune 4 27 load a custom tune file 4 8 load a dynojet tune file 4 4 Start autotune 4 21 pv info 3 17 pv toolbar 3 32 Index iv WinPV User Guide Q quick tune config 4 35 configure 4 34 fuel 4 37 general 4 34 Spark 4 37 tweaks 4 36 ve 4 38 R read ecm 4 51 redo 3 16 reset trims 4 50 reset trip economy A 4 46 reset trip economy B 4 47 reset ul 3 32 reset user interface 3 32 restore original tune 4 52 rpm limit 3 50 S Save 3 34 save all values 3 9 Save as 3 6 save selected values 3 10 Save selected values append 3 11 Scalar 3 39 send original tune to pv 3 23 send stock file to pv 3 24 send tune 3 18 3 35 send tune to pv 3 18 disable EUAO 3 18 lock tune 3 18 set 3 36 settings menu 4 53 brightness 4 53 code 4 55 flip screen 4 55 touch calibrate 4 55 units 4 53 setup menu 3 28 apply license 3 31 options 3 28 Show delta as percent 3 27 Show only differences 3 27 Signals 4 46 Smooth 3 16 software level 3 42 Spark 3 51 adaptive knock retard 3 51 closed throttle spark front 3 51 closed throttle spark rear 3 52 max knock retard 3 51 PE spark 3 51 Spark adjust by air temp 3 52 Spark adjust by engine temp 3 52 Spark adjust by head temp 3 52 Spark advance front 3 51 Spark advance rear 3 51 Spark adjust by air temp 3 52 Spark adjust by engine temp 3 52 Spark adjust by head temp 3 52 Spark advance front 3 51 Spark advance rear 3 51 Spark quick tune 4 37 speedometer calibration 3 49 Standard toolbar 3
82. menu 3 28 view menu 3 32 WinPV toolbar 3 34 cell math toolbar 3 36 compare toolbar 3 37 powervision toolbar 3 35 standard toolbar 3 34 WinPV update client 2 5 WinPV user interface 3 2 Index v WinPV User Guide
83. mup Steps CIE Ide RPM CJE Ide RPM Adder m C AN Throttle Blade Control C B Throttle Blade Control Al CJA Throttle Table Transition CIA VE Front Cyl CIA VE Rear Cyl fy Environment fy Fuel pi Gear fey Limits amp Switches Ag Spark 3 41 Version 7 WinPV User Guide aj a a CHAPTER 3 a Tune Items Tune Info tune item Description description This is the vehicle and ECM description Displays Year Make Calibration ID Software Level Lambda Based Airflow 3 42 tune item Charge Dilution Effect Model Vin and ECM part number This is the stock ECM calibration ID number This is the ECM software This indicates if this is a Lambda bases calibration Not editable description This estimates the increase in intake pressure that is due to Front Cyl Charge Dilution Effect Rear Cyl Charge Dilution Effect Drive By Wire Throttle Limit vs Gear Engine Displacement IAC Warm up Steps WinPV User Guide Charge Dilution Effect for the front cylinder Expressed as 0 0 and 256 2 This estimates the increase in intake pressure that is due to Charge Dilution Effect for the rear cylinder Expressed as 0 0 and 256 2 This estimates the increase in intake pressure that is due to Charge Dilution Effect for both cylinders Expressed as 0 0 and 256 2 These values are used by Drive By Wire DBW engine speed governing In most cases these values sh
84. n Dealer Info Menu To View Information About the Dealer Version 7 WORKING WITH POWER VISION Sx Power Vision Menus WinPV User Guide 4 3 CHAPTER 4 i amp Power Vision Menus Program Vehicle Menu The Power Vision accepts custom tune files created in WinPV and pre loaded Dynojet tunes installed in the Power Vision memory from Dynojet Research To flash or edit tune files the Power Vision must be married to the ECM Marrying the Power Vision to the ECM locks the Power Vision module to that ECM and prevents a single device from being used on multiple ECMs You cannot unlock a Power Vision from a married ECM Once the marriage process Is complete you can open the stored calibration in the WinPV software to edit all parameters or change Dynojet specific functions on the device To Load a Dynojet Pre Configured Tune File Use the following steps to load a Dynojet pre configured tune file to the ECM 1 Turn the ignition key to the On position 2 Verify the Run Off switch is in the Run position 3 Touch Program Vehicle gt Load Tune gt Dynojet Pre Configured Tunes Select the type of tune to load into tune manager _ SJ a eee 4 T j ir F i j p F Ss l Ji F PJ J __PRE CONFIGURED TUNES eustrom voxv copvor TUNES STOCK Cancel 4 4 WinPV User Guide WORKING WITH POWER VISION he Power Vision Menus Touch a Dynojet tune file to load 5 Touch Select to continue with the s
85. n Max Spark Learn The maximum amount in degrees that a Spark cell is allowed to change Set this to 0 to disable Spark learning A good starting value would 10 degrees Continue 4 30 WinPV User Guide WORKING WITH POWER VISION Be Power Vision Menus ox 6 Using the number pad enter the value for the setting The numeric display will show the current value The default value is shown under the setting title In this example 10 degrees was entered This will enable spark tuning up to 10 degrees 7 Touch Save to confirm the value or Cancel to return to the list of settings PowerVision Application Enter Max Spark Learn Default is 0 00 Degrees 8 Touch Yes to confirm the changes Or Touch No to abort the process PowerVision Application Confirm Set Max Spark Learn to 10 00 Degrees 4 31 TETEE WinPV User Guide yey CHAPTER 4 SE Power Vision Menus The setting value is updated In this example Max Spark Learn is now 10 degrees 9 Touch Exit to exit the Setting screen PowerVision Application Ea Select Setting to EDIT Reset all to DEFAULTS za Min Hit Count 5 ticks Us Min VE Learn 0 01 Percent Max VE Learn 15 00 Percent Min Spark Learn 1 00 Degrees Max Spark Learn 10 00 Degrees Min WB Lambda 0 68 Lambda Max WB Lambda 1 22 Lambda M Min Engine Temp 75 0 DeqC Exit s s Select If y
86. nits 2 Touch English or Metric 3 Touch Back to return to the Setting menu Select Units English Metric English To Change the Brightness 1 Touch Settings gt Brightness 2 Use the arrows to Increase or decrease the brightness of the Power Vision screen 3 Touch Save to confirm the changes Or Ses 4 Version 7 WinPV User Guide CHAPTER 4 x Power Vision Menus Touch Cancel to return to the Settings menu Adjust Brightness aari 100 gt i Cancel 4 54 WinPV User Guide WORKING WITH POWER VISION ks Power Vision Menus To Enter a Code 1 Touch Settings gt Enter Code 2 Using the number pad enter a code 3 Touch Save to save the code Or Touch Cancel to return to the Settings menu Enter Code To Calibrate the Touch Screen Use the following steps to calibrate the Power Vision touch screen 1 Touch Settings gt Touch Calibrate 2 Touch the plus signs as they appear The calibration process will complete once all points have been touched To Flip the Power Vision Screen Flip Screen rotates the Power Vision screen orientation 180 degrees Touch Settings gt Flip Screen To Return to the Power Vision Main Menu Touch Back 4 55 Version 7 WinPV User Guide N CHAPTER 4 SE Power Vision Menus Device Info Menu To View Information About the Power Vision Device Info displays information about the Power Vision Touch Device Info Device in
87. ns select the File menu then select the Open choice on the File menu Words highlighted in blue indicate a link MD 1 2 DOTA 3 WinPV User Guide GETTING STARTED This section will guide you through installing the Power Vision drivers checking the WinPV Update Client installing the Power Vision on your motorcycle and saving a stock calibration This section is divided into the following categories e Power Vision Driver Installation page 2 2 e Checking the WinPV Update Client page 2 5 e Installing the Power Vision on the Motorcycle page 2 9 e Power Vision Tune File Management page 2 12 Mayme a 2 1 WinPV User Guide CHAPTER 2 F Power Vision Driver Installation Power Vision Driver Installation Windows XP Driver Installation Windows Vista and Windows 7 Driver Installation Windows XP Driver Installation 1 Using the USB cable connect the Dynojet Power Vision to your computer The Found New Hardware window will open 2 Select Yes this time only and click Next Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for curent and updated software by looking on Your computer on the hardware installation CD or on the Windows Update web site with your permission Read our privacy policy Can Windows connect to Windows Update to search for sottware Yes now and every time connect a device No not this time Click Next to continue
88. ntrol Power Enrichment Mode will be activated at RPMs greater than this setting To disable PE set this value to your RPM limit or greater than your RPM limit This tells the ECM if the vehicle has active exhaust control A value of zero means this vehicle does not have this feature or Shuts off the input to the ECM Available in pro user level only This tells the ECM if the vehicle has active intake A value of zero means this vehicle does not have this feature or shuts off the input to the ECM Available in pro user level only This tells the ECM if the vehicle has active compression release A value of zero means this vehicle does not have this feature or shuts off the input to the ECM Available in pro user level only This tells the ECM if the vehicle has heated O2 sensors A value of zero means this vehicle does not have this feature or Shuts off the input to the ECM Available in pro user level only Power Enrichment Mode will be activated if TPS is greater than this setting Available in pro user level only tune item PE Disable TPS PE Disable RPM Closed Loop Spark tune item PE Spark Spark Advance Front Spark Advance Rear Max Knock Retard Adaptive Knock Retard Closed Throttle Spark Front Version 7 WORKING WITH WINPV bs ss Tune Items description Power Enrichment Mode will be disabled if TPS is less than this setting Available in pro user level only Power Enrichment Mode w
89. nu 4 56 device info 4 56 disable EUAO 3 18 divide 3 36 drive by wire speed limit vs gear 3 44 drive by wire throttle limit vs gear 3 42 drivers 2 2 DTCs 4 49 dynojet tune file 4 4 E ecm status 4 16 edit 3 16 copy 3 16 cut 3 16 interpolate 3 16 interpolate horizontal 3 16 redo 3 16 Smooth 3 16 undo 3 16 edit a tune file 4 15 edit autotune settings 4 29 edit menu 3 16 edit tune 4 15 EITMS 3 50 EITMS off temp 3 45 EITMS on temp 3 45 email contact 1 1 enable autotune 4 17 engine displacement 3 42 environment 3 45 adaptive control enable temp 3 45 adaptive control maximum temp 3 45 adaptive control maximum temp hysteresis 3 46 adaptive control minimum temp hysteresis 3 46 closed loop minimum temp 3 46 closed loop minimum temp hysteresis 3 46 EITMS off temp 3 45 EITMS on temp 3 45 knock control minimum temp 3 45 knock control minimum temperature hysteresis 3 45 exit pc link mode 3 24 export a learned tune 4 24 F file import power commander map file 3 7 load all values 3 12 load selected values 3 14 open 3 5 Save all values 3 9 Save as 3 6 Save selected values 3 10 save selected values append 3 11 file menu 3 5 flip screen 4 55 fuel 3 47 acceleration enrichment 3 47 acceleration enrichment multiplier 3 48 air fuel ratio lambda 3 47 air fuel ratio stoich 3 47 cranking fuel 3 47 deceleration enleanment 3 47 deceleration enrichment multiplier 3 48 injector gas constant 3 48 injector size 3
90. on engine temperature A larger number will supply more fuel during the cranking cycle A smaller number will reduce the amount of cranking fuel during the cranking cycle Cranking Fuel only applies to Starting the engine when the starter Is active Deceleration Enleanment Deceleration Enleanment mode can be triggered by a sudden decrease in throttle position or MAP pressure To increase the fuel delivered on deceleration decrease the value To reduce the amount of fuel delivered increase the value 3 47 Version 7 WinPV User Guide FJ 3 48 CHAPTER 3 aj Tune Items tune item PE Air Fuel Ratio Lambda Stoich Warmup Enrichment Lambda Warmup Enrichment Stoich Acceleration Enrichment Multiplier Deceleration Enrichment Multiplier MPG Adjustment Injector Gas Constant WinPV User Guide description Power Enrichment mode is active at higher RPMs and when the throttle position is greater than 95 percent The purpose of PE mode is to operate the engine at maximum torque AFR and spark values for a short time then adjust to more conservative values to reduce engine temperature Available in pro user level only The warm up enrichment table adds additional fuel after start up The fuel from this table decays out over time The table is activated only once per key on If the engine stalls and is restarted without cycle in the ignition enrichment continues from its value when the stall occurred The wa
91. ote The Update Client needs to be restarted for any further updates The Welcome to the Power Vision Software Setup Wizard window will appear 2 5 Version 7 WinPV User Guide x CHAPTER 2 Y Checking the WinPV Update Client 9 Click Next to continue fey Power Vision Software Setup Welcome ta the Power Vision Software Setup Wizard The Setup Wizard will install Power vision Software on your computer Click Next to continue or Cancel to exit the Setup Wizard Cancel 10 Carefully read the Power Vision software license agreement check the accept box and click Next to continue To install the Power Vision software you must accept this agreement If you do not Setup will close ig Power Vision Software Setup Power Vision Software Setup Please read the Following license agreement carefully USER LICENSE AGREEMENT FOR DYNOQJET RESEARCH Power Vision IMP ORTANT READ CAREFULLY This User License Agreement herein after referred ta as CULA is a legal agreement between you either an individual or a single entity and Dynojet Research Inc for the software identified above Power Vision and any hardware developed by Dynojet Research Inc or its suppliers that is used in association with Power Vision Power Vision includes computer software the associated media any printed materials any online or electrome documentation and associated hardware 2 6 DOTA WinPV User Guide GETTING STARTED he
92. ottle transition gear has been reached Drive by wire Harleys use two throttle blade control tables To use Throttle Blade Control Stage exclusively set Throttle Transition Gear to 6 The Volumetric Efficiency Front table is for the front cylinder and is the table that models engine airflow so AFR can be accurately calculated The values in this table are influenced by the camshaft exhaust system head design engine displacement and air filter This is the most critical item that must be correct in order to make the bike run correctly To increase fuel make the values larger To decrease fuel make the values smaller WinPV User Guide FJ 3 44 re CHAPTER 3 ae Tune Items tune item VE Rear Idle RPM Adder Throttle Table Transition Gear DBW Throttle Position Limit Drive By Wire Speed Limit vs Gear WinPV User Guide description The Volumetric Efficiency Rear table is for the rear cylinder and is the table that models engine airflow so AFR can be accurately calculated The values in this table are influenced by the camshaft exhaust system head design engine displacement and air filter This is the most critical item that must be correct in order to make the bike run correctly To increase fuel make the values larger To decrease fuel make the values smaller This is an idle soeed RPM adder Positive values will add RPM to the entire IDLE RPM Function while negative values will reduce RPM This is
93. ou need assistance on recommended values for different families of bikes please email PVtech dynojet com AutoTune Settings The following table lists the various AutoTune settings and a description of each setting setting Min Hit Count ticks Min VE Learn Percent Max VE Learn Percent Min Spark Learn Degrees Max Spark Learn Degrees Min WB Lambda Lambda Max WB Lambda Lambda 4 32 WinPV User Guide description The minimum number of hits on a cell for learning to take place The minimum amount a VE cell needs to learn before a change will take place The maximum amount a VE cell is allowed to change in VE units Set this to O to disable VE learning The minimum amount a Spark cell needs to learn before a change will take place The maximum amount in degrees that a Spark cell is allowed to change Set this to O to disable Spark learning A good starting value would 10 degrees The richest value aS measured on the Wideband in Pro Mode that is allowed This is in Lambda The leanest value aS Measured on the Wideband in Pro Mode where learning is allowed This is in Lambda setting Min Engine Temp DegC WORKING WITH POWER VISION Power Vision Menus description The coldest engine temperature where Max Engine Temp DegC Min RPM RPM Max RPM RPM Min MAP KPA Max MAP KPA Default AutoTune Settings learning is allowed entered in Degrees Celsius or Fahrenheit dep
94. ouch OK to confirm your selection Or Touch Cancel to return to the Set Gauge Properties screen Assign Signal Accel Enrichment Barometer Battery Voltage Brake Clutch State Coast Cruise Enable Cruise Engauge Ok s Cancel 9 To set the minimum value for the signal 9a Touch L Limit 9b Using the number pad enter the minimum value for the signal 9c Touch Save to confirm the value or Cancel to return to the Set Gauge Properties screen Enter MINIMUM value for signal 4 42 WinPV User Guide WORKING WITH POWER VISION ks Power Vision Menus hs 10 To set the maximum value for the signal 10a Touch H Limit 10b Using the number pad enter the maximum value for the signal 10c Touch Save to confirm the value or Cancel to return to the Set Gauge Properties screen Enter MAXIMUM value for signal 11 To set the low warning value for the signal Lia Touch L Warning 11b Using the number pad enter the low warning value for the signal 11c Touch Save to confirm the value or Cancel to return to the Set Gauge Properties screen Enter LOW WARNING value for signal Fi a 9 f 4 5 6 Clear 4 43 Version 7 WinPV User Guide CHAPTER 4 pr Power Vision Menus 12 To set the high warning value for the signal 12a Touch H Warning 12b Using the number pad enter the high warning value for the signal 12c Touch Save to confirm the value or Cancel to return to the Set Gauge Pro
95. ould be changed to 255 in order to ensure the desired rev limit is actually used When the rev limit is approaching DBW bikes nudge the throttle towards this position specified for each gear O Throttle Closed 255 Throttle Wide Open 100 TP Set these to 255 to remove this limit or to a value that works with your desired rev limit This value is the displacement of both cylinders When changing engine size it s easier to ratio this value up and down by the difference in displacement Input the actual engine displacement into this field Available in pro user level only The Intake Air Control Warm up Steps table is used to maintain a stable idle during warm up This table determines the initial position of the IAC motor to maintain RPM at a given temperature The closer this table is to the actual IAC opening the better the idle will be Available in pro user level only tune item Idle RPM MAP Load Normalization MAP Tooth IVC Front Cyl MAP Tooth IVO Front Cyl MAP Tooth Offset Rear Cyl MAP Default Table Number of Crank Teeth Throttle Blade Control Stage II Throttle Blade Control Stage VE Front Version 7 WORKING WITH WINPV bs ss Tune Items description The Idle speed is controlled by the idle RPM table as a function of engine temp To increase idle make these values larger To decrease idle make these values smaller Available in pro user level only Setting Idle RPM below 900 RPM can
96. perties screen Enter HIGN WARNING value for signal TAIENSIS fa 5 6 Cancel 13 Touch OK to confirm your changes Or Touch Cancel to return to the gauge screen 14 Touch Exit to exit the Datalog menu 15 Touch Back to return to the Power Vision main menu 4 44 WinPV User Guide WORKING WITH POWER VISION S Power Vision Menus To Playback a Log Playback allows you to play back recorded log files saved on the Power Vision Touch Datalog gt Playback Touch a log to view Touch View to view the log Touch Delete to delete the log Touch Exit to return to the Datalog menu ul BhWN Select Log to View 4 45 Version 7 WinPV User Gilde ay CHAPTER 4 ye Power Vision Menus To View Signals Signals are channels that can be logged on the Power Vision You can add edit or delete channels that are data logged 1 Touch Datalog gt Signals 2 To edit one of the channels from the list 2a Select a channel from the list 2b Touch Edit to change the gauge properties for the selected channel For more information about editing gauge properties refer to To View Gauges and To Create Gauge Limits and Visual Warnings Data Logging Global Signals Acel Enr A f Decl Enl Set Air Fuel UX Set Air Fuel Front AFF ET Spark Knock Front CLI INJ PW F Idle Set IAT INJ PW R Rear AFF MAP Spark Knock E f ext aca f ii s 3 To remove a channel from the list 3a Select a ch
97. py Paste Print About POE A description of the standard toolbar buttons and functions follows press this button to Open previously saved or stored tunes Refer to Io r Open a Power Vision Tune File PVT Open Save the current tune to your computer Refer to To_ lel Save a Power Vision Tune File PVT Save Cut the highlighted cell values Copy the highlighted cell values Paste the copied values About allows you to view information about WinPV About 3 34 OOJ A WinPV User Guide WORKING WITH WINPV WinPV Toolbar PowerVision Toolbar eo 4 i rd Info GetTune Send Tune GetECM Get Log Data A description of the Power Vision toolbar buttons and functions follows press this button to Display the Power Vision information Refer to To View the PowerVision Information Info Retrieve a tune from the Power Vision The tune EI information will be shown in the Tune Items Refer to To Get Tune Get a Tune from the Power Vision Sends the current tune to the Power Vision Refer to To Ei Send a Tune to the Power Vision send Tune Get ECM Data is for diagnostic and development rd purposes only The files may not be needed and are not Get ECM generally useful unless requested by technical Support Data Refer to To Get ECM Data from the Power Vision z Retrieve the log files on the Power Vision Refer to To Get a Log from the Power Vision Get Log Version 7 WinPV User Guide 3 35
98. r Vision 5b Click to browse to the Tune Files folder you created 5c Click OK to save the location Property Value Units Metric User Level Pro Stock Files Folder C Program Files Power visions Stock Files Tune Files Folder C Program Files Power Vision Tune Files Value Files Folder C Program Files Power Vision alue Files Tune Files Folder This ig the default location where Power Vision Tune files pvt are stored on your computer Ok Cancel i z of Outlook Express Fl Power Commander 5 ly Power vision ED Drivers ef 9 Stock Files ORIS r PS Value Files FPS QuickTime HES Reference Assemblies APS Remove WebWorks ey Ravin i WinPV User Guide WORKING WITH WINPV ks WinPV Menus is 6 To create the default location where the Power Vision value files pvv are stored on your computer 6a Create a Value Files directory in C Program Files Power Vision 6b Click to browse to the Value Files folder you created 6c Click OK to save the location Property Value Units Metric User Level Pro Stock Files Folder C Program Files Power VisionStock Files Tune Files Folder C Program Files Power Vision T une Files Value Files Folder C Program Files Power VisionsValue Files Value Files Folder This iz the default location where Power Vision value files pww are stored on your computer cei e zi of Outlook Express H Power Commander 5 Stock Fil
99. r Vision tune file from the Power Vision refer to To Get a Tune from the Power Vision Use the following steps to open a Power Vision tune file from your computer 1 Select File gt Open 2 Select a pvt file to open 3 Click Open Look in Tune Files O F c file My Recent Documents Desktop My Documents wn PI My Computer 10 FB4 QEBXZ8E 01 p t ke 2010 Tour Rush 2into1 1 75 baffle pvt im My Network File name gt Places Files of type Power Vision Tune pvt Cancel Version 7 WinPV User Guide Pa 3 5 aN CHAPTER 3 WinPV Menus To Save a Power Vision Tune File PVT If the Tune File directory does not exist or if you haven t already created the Tune File directory you will need to create a Tune File directory in C Program Files Power Vision Once the Tune File directory is created you must map this folder in Setup Options Refer to To Setup the Options 1 Select File gt Save As 2 Enter a name for your tune file 3 Click Save Save As 21x Save in E Tune Files gt F o m Fe My Recent Documents Desktop My Documents PI My Computer a My Network File name Juntitled pvt Places Save as type Power Vision Tune pyt Cancel 3 6 mma WinPV User Guide WORKING WITH WINPV Fa WinPV Menus h To Import a Power Commander Map File pvm djm 1 Make sure you have a tune loaded You must have a
100. rks Visual Studio Tools for Applica 9 Visual Studio 2005 Eh Lll L rm ae F Make Mew Folder Cancel A 3 22 WinPV User Guide WORKING WITH WINPV Sx WinPV Menus 5 The Get ECM Data Results have been saved Click OK Get ECM Data Results X 1 of 1 saved in Documents and Settings suzannelMy Documents Power vision Diagnostics To Send the Original Tune to the Power Vision 1 Select PowerVision gt Diagnostic Test Functions gt Send Original Tune to PV 2 Browse to the location of the original tune you would like to send to the Power Vision 3 Select the tune file and click Open Select ORIGINAL Tune to send to P EIEI Look in lo Original Tunes O F gt fie My Recent Documents Desktop My Documents 4MADX00044000154 10 FB4 xIMT6GH b1c9F2Fb stk Pr My Computer KL File name ot __ Cancel None Files of type PowerVision Stock Files stk Cancel Places 7 Open as read only 4 Click OK 3 23 Version 7 WinPV User Guide CHAPTER 3 WinPV Menus To Send a Stock File to the Power Vision 1 2 3 4 Select PowerVision gt Diagnostic Test Functions gt Send STK File to PV Browse to the location of the stock file you would like to send to the Power Vision Select the stock file and click Open Select STK File to Send to Power ision Look in E Stock Files F gt E My Recent Documents Desktop X 10 FB4 xXIMT6GH 01 s
101. rm up enrichment table adds additional fuel after start up The fuel from this table decays out over time and it is only active for 20 to 30 seconds The table is activated only once per key on If the engine stalls and is restarted without cycle in the ignition enrichment continues from its value when the stall occurred This will determine the total amount of fuel to add during rapid changes in acceleration To globally increase the amount of fuel added during acceleration enrichment increase this vale To reduce the amount of fuel delivered decrease this value Available in pro user level only This will determine the total amount of fuel to add or reduce during rapid changes in acceleration To globally increase the amount of fuel added during deceleration enrichment decrease this vale To reduce the amount of fuel delivered increase this value Available in pro user level only This adjusts the MPG readout for the bike Higher values show a higher MPG lower values show lower MPG This is a constant used internally for fuel injector calculations It is not advised to change this value Closed Loop tune item Closed Loop Bias Front Closed Loop Bias Rear Closed Loop Bias Closed Loop Lambda Range Gear tune item Speedometer Calibration WORKING WITH WINPV Ls ss Tune Items description The closed loop bias table is used to adjust the closed loop AFR Setting the value in this table to 450 mV will result
102. rsion 1 0 0 1 0 0 G5 version 2 6 30 47 PREEMPT Mon Dec 6 11izi Tune Database version 0 0 2 CT Version 00 01 00 00 01 02 To Get a Tune from the Power Vision 1 Select PowerVision gt Get Tune from PV or click the Get Tune button pi 2 Select a tune to load Get Tune 3 Click OK Select CUSTOM TUNE to Load into WinP 1 2010 Harley Road King_ stock pwt 3 EMPTY 4 EMPTY Cancel i 3 17 Version 7 WinPV User Guide i TO 1 3 18 xy CHAPTER 3 p WinPV Menus Send a Tune to the Power Vision Select PowerVision gt Send Tune to PV or click the Send Tune button ey Send Tune Using the drop down arrow select a Custom Tune Slot on the Power Vision to send the tune to Click Lock Tune to prevent a tune from being retrieved using Get Tune Click Disable EUAO to disable the End User Adjustable Options This will prevent a tune from being edited on the Power Vision Click OK to send the tune to the Power Vision Or Click Cancel to close the window without changes Send Tune to P x Filename WOT Z055AD01 dt0 working bin pwt Mame on PY WOT 20554001 dt0 working bin pwt Custom Tune Slot l Lock Tune Disable EUG k Cancel WinPV User Guide WORKING WITH WINPV T WinPV Menus hi To Get a Log from the Power Vision 1 Select PowerVision gt Get Log from PV or click the Get Log button f Get Log 2 Select the log file you wish to get from the Power Vision 3 Click Get
103. running If there is an error between what the ECM is asking for and what the OEM narrowband sensor measures a correction is made to adjust the lean or rich condition These corrections are stored in what are called Adaptive fuel tables Narrowband sensors are ONLY accurate at or near the stoichiometric value of the fuel being used which is 14 7 1 for gasoline This value is where complete combustion would occur however is not ideal for all operating conditions of an engine A typical Harley Davidson ECM calibration has areas of closed loop and open loop Open loop means feedback from the O2 sensors is not used When the engine is in a range that requires precise measurement but is outside the reliable window of a narrowband sensors operation considered 14 3 15 2 AFR then a tuner EFI specialist must rely on wideband O2 sensor data The wideband O2 sensor values provide tuners or electronic tuning devices with data needed to make decisions on how they will address fueling in the open loop areas of the ECM calibration In the case of a Harley engine management system we fix the error by adjusting the Volumetric Efficiency tables Power Vision offers two methods for AutoTune e AutoTune Basic utilizes the narrowband O2 sensors on bikes that have OEM closed loop fuel control Refer to AutoTune Basic e AutoTune Pro requires the use of Dynojet s AutoTune wideband O2 control module that has dual wideband O2 sensors Refer to AutoTune Pro
104. s 0 00 ee 1 2 Chapter 2 Getting Started Power Vision Driver Installation 000 2 2 Windows XP Driver Installation 0 00 eee eee 2 2 Windows Vista and Windows 7 Driver Installation 2 4 Checking the WinPV Update Client 2 5 Installing the Power Vision on the Motorcycle 2 9 Power Vision Tune File Management 00 2 12 Flashing a Dynojet Pre Configured Tune File 2 14 Flashing a Custom Tune File 0 0 ee eee ees 2 17 Loading a Copy of the Original Tune File or a Copy of the Current Tune File 0 2 00 eee 2 19 Chapter 3 Working with WinPV WinPV User Interface 0 0 000 es 3 2 WinPV Menus 0 000 ee ee 3 3 Help Menu 1 es 3 4 File Menu 0 es 3 5 To Open a Power Vision Tune File PVT 005 3 5 To Save a Power Vision Tune File PVT 0 5004 3 6 To Import a Power Commander Map File pvm djm 3 7 To Save All Values 2 0 0 0 0 ee ee 3 9 To Save Selected Values 0 000 ee ee es 3 10 To Save Selected Values Append 0 0000 3 11 To Load All Values 0 00 0 a 3 12 To Load Selected Values 0 000 eee ee ee es 3 14 To Exit the WinPV Software 0 000 eee ee ee es 3 15 WinPV User Guide a TABLE OF CONTENTS WinPV User Guide Edit Menu 0 a 3 16 FOUNO swicewmnanaeeeeceu Peed eee ee eee eete ane na es 3 16 TO REGO 2g
105. s loaded in the Tune Manager prior to flashing your ECM The Power Vision allows you to make basic adjustments to your tunes directly on the device without using a computer In order to gain full access to your tune files you ll need to download them from the Power Vision to WinPV our custom tuning software WinPV User Guide GETTING STARTED Yo Power Vision Tune File Management ot Flashing a Custom Tune File Custom Tunes may or may not be pre loaded from a reseller that specializes in custom tuning Dynojet does NOT load custom tunes in the Power Vision when it leaves our facility we load Dynojet Pre Configured Tunes You may also receive Custom Tunes via email that can be uploaded to the Power Vision using WinPV our custom tuning software Use the following steps to flash a Custom Tune file to the ECM 1 Touch Program Vehicle gt Load Tune gt Custom Tunes Select the Type of tune to imad into the tune manager i F LS custom rence TUNES COPY Cancel 2 Select a Custom Tune File to flash 3 Touch Select Please select available Tune Slot 1 Stock Read Slot 2 Tab Slipon_KandN Filter Slot 3 Empty Slot 4 07T096002306 Slot 5 O7TO96002412 Slot 6 O7T096002301 Select i Cancel 2 17 Version 7 WinPV User Guide r 4 2 18 x CHAPTER 2 amp Power Vision Tune File Management Verify the tune information If the tune information is correct touch Continue Slot
106. steps 3 42 idle rom 3 43 idle rom adder 3 44 map default table 3 43 map load normalization 3 43 map tooth IVC front cyl 3 43 map tooth IVO front cyl 3 43 map tooth offset rear cyl 3 43 number of crank teeth 3 43 throttle blade control stage 3 43 throttle blade control stage II 3 43 throttle table transition gear 3 44 VE front 3 43 VE rear 3 44 air fuel ratio lambda 3 47 air fuel ratio stoich 3 47 airflow 3 42 apply license 3 31 NDEX autotune basic 4 19 4 58 4 59 changes made 4 60 datalog 4 21 datalogger modes 4 24 datalogger operating conditions 4 23 edit settings 4 29 enable 4 17 export a learned tune 4 24 load a custom tune 4 27 log tuner 4 22 notes and tips 4 61 pro 4 19 4 58 4 59 Start session 4 21 understanding 4 58 wideband o2 4 60 B backup stk 3 35 basic autotune 4 59 basic autotune mode 4 19 brightness 4 53 C calibrate touch screen 4 55 calibration ID 3 42 cell colors 3 26 3 37 compare high low 3 26 table range 3 26 cell math toolbar 3 32 3 36 add 3 36 customizing 3 38 divide 3 36 multiply 3 36 percent 3 36 set 3 36 subtract 3 36 value 3 36 cells copy 3 16 paste 3 16 Index i WinPV User Guide charge dilution effect 3 42 charge dilution effect front 3 42 charge dilution effect rear 3 42 close compare 3 25 3 37 closed loop 3 49 3 51 closed loop bias front 3 49 clossed loop bias 3 49 clossed loop bias rear 3 49 clossed loop lambda range 3 49 closed loop bias 3 49 c
107. t View gt Reset UI 3 32 ee WinPV User Guide WORKING WITH WINPV WinPV Menus Bx Help Menu To View the About Window Select Help gt About About WinP Y i To View the Power Vision Help Files Select Help gt Contents Welcome to Dynojet WinPV Software The Software Engineers at Dynojet understand your need to attain performance from the you evaluate and tune For this reason they have developed a user friendly easily develop new fuel and ignition maps record and download log files ith the cick of a button Whether you are new to the benefits of dyno testing s performance leader the Power Vision in Conjunction with the WinPy software will give you the professonal results you are looking for WinPV Help provides information and step by step guidance for common tasks as well as descriptions of each field on each window Version 7 WinPV User Guide 3 33 a CHAPTER 3 r WinPV Toolbar WinPV Toolbar The following toolbar is always shown contains the WinPV tools The WinPV toolbar is grouped into four sections and each toolbar can be customized standard toolbar cell math toolbar t gt E r Table Range Info GetTune SendTune GetECM GetLlog lose ompare elta Cell Colors Data X Compare Compare le PowerVision toolbar compare toolbar Standard Toolbar PowerVision Toolbar Cell Math Toolbar Compare Toolbar Customizing the Toolbars Standard Toolbar w HU F amp Open Save Cut Co
108. terpolate Selected Horizontal Values To Interpolate Selected Vertical Values 3 3 Version 7 WinPV User Guide Y CHAPTER 3 F WinPV Menus PowerVision Menu To View the PowerVision Information To Get a Tune from the Power Vision To Send a Tune to the Power Vision To Get a Log from the Power Vision To Update the Tune Using the Power Vision To Get ECM Data from the Power Vision To Send the Original Tune to the Power Vision To Send a Stock File to the Power Vision To Exit PC Link Mode Compare Menu To Load a Compare File To Close the Compare File To View the Active File To View the Compare File To View Delta To Choose Cell Colors To Show Only Differences To Show Delta As Percent To Create Difference Report Setup Menu To Setup the Options To Apply the License View Menu To View the Standard Toolbar To View the Cell Math Toolbar To View the PowerVision Toolbar To View the Compare Toolbar To Reset the User Interface Help Menu To View the About Window To View the Power Vision Help Files 3 4 WinPV User Guide WORKING WITH WINPV WinPV Menus File Menu To Open a Power Vision Tune File PVT If the Tune File directory does not exist or if you haven t already created the Tune File directory you will need to create a Tune File directory in C Program Files Power Vision Once the Tune File directory is created you must map this folder in Setup Options Refer to To_ Setup the Options To open a Powe
109. tk My Documents nm BL My Computer File name 10 FB4XJMTEGH 01 stk a Teena Files of type PowerVision ECM Image Files stk Cancel Places Open as read only Click OK To Exit PC Link Mode Exit PC Link Mode allows you to edit gauge features while plugged into the PC using the Supplied USB cable Select PowerVision gt Diagnostic Test Functions gt Exit PC Link Mode 3 24 WinPV User Guide WORKING WITH WINPV Sx WinPV Menus h Compare Menu To Load a Compare File Compare file allows the individual tune items of two different tune files to be compared The Active file can be edited cell values can be copied from the Compare file and the Delta feature can be used to change the Active file For more information about the Delta file refer to To View Delta 1 Select Compare gt Load Compare or click the Load Compare button E 2 Select a tune file to Compare Faek 3 Click Open Select PT rle to compare T Look in Tune Files o 2 eE fe e My Recent Documents Desktop My Documents on oe My Computer we File name dren Neuere Files of type PVT Files pvt Cancel Places T Open as read only 10 FB4 QEBx26E 01 pvt Me 2010 Tour Rush 2into1 1 75 baffle pvt To Close the Compare File Select Compare gt Close Compare or click the Close Compare button x This will close the Compare File and return to a single active tune file Reni ompare
110. to get the log file from the Power Vision Or Click Get Delete to get and delete the log file from the Power Vision Or Click J ust Delete to delete the log file from the Power Vision Select LOG files to Get from PY Get Delete Just Delete 3 19 Version 7 WinPV User Guide ACY CHAPTER 3 iF WinPV Menus 4 Browse to the location you wish to save your log file and click OK Browse For Folder Seleck Folder bo Save To 9 Online Services 3 Outlook Express 9 Power Commander 5 E G Power vision oo Drivers D Log Files Ta Maps C Stock Files 9 Tune Files O Value Files 9 QuickTime 9 Reference Assemblies 3 Remove WebWorks C Roxio afl 5 Click OK The log file is now ready to be opened with Excel Get Log Results xj 1 of 1 backed up 3 20 WinPV User Guide WORKING WITH WINPV Sx WinPV Menus To Update the Tune Using the Power Vision Update the Tune Using the Power Vision will upgrade the tune with any new tune items that are possibly exposed in newer Power Vision firmware that the version that this tune was created with A new tune will be created so the original tune should be saved and left alone for backup Note This may render the new tune incompatible with older firmware revisions Be sure to save the original backup 1 Select PowerVision gt Update Tune Using PV 2 Click Yes to continue Upgrade Tune m x This will upgrade the tune
111. tooth IVO front cyl 3 43 map tooth offset rear cyl 3 43 max knock retard 3 51 mpg adjustment 3 48 multiply 3 36 number of crank teeth 3 43 O open 3 5 3 34 options 3 28 stock files 3 29 tune files 3 30 units 3 28 value files 3 31 Index iii WinPV User Guide paste 3 16 3 34 paste cells 3 16 PE air fuel ration lambda stoich 3 48 PE disable rom 3 51 PE disable tps 3 51 PE enable rpm 3 50 PE enable tps 3 50 PE spark 3 51 percent 3 36 phone contact 1 1 playback a log 4 45 power vision drivers installing 2 2 power vision information 3 17 power vision menus 4 2 datalog menu 4 39 dealer info menu 4 57 device info menu 4 56 program vehicle menu 4 4 settings menu 4 53 vehicle tools menu 4 48 power vision toolbar 3 32 power vision tune file open 3 5 Save as 3 6 power vision installing 2 9 powervision menu 3 17 exit pc link mode 3 24 get ECM data 3 21 get log from pv 3 19 get tune from pv 3 17 pv info 3 17 send original tune to pv 3 23 send stock file to pv 3 24 send tune to pv 3 18 update tune using pv 3 21 powervision toolbar 3 35 backup stk 3 35 customizing 3 38 get log 3 35 get tune 3 35 Info 3 35 send tune 3 35 pro autotune 4 59 pro autotune mode 4 19 program vehicle menu configure quick tune 4 34 ecm status 4 16 edit a tune file 4 15 edit autotune settings 4 29 enable autotune 4 17 export a learned tune 4 24 load a copy of current tune file 4 12 load a copy of original tune file 4 9 load a custo
112. u will need to create a Value File directory in C Program Files Power Vision Once the Value File directory is created you must map this folder in Setup Options Refer to To Setup the Options 1 Select File gt Load All Values 2 Select the pvv file you would like to use and click Open Select P File to IMPORT Look in Value Files QO e egm My Recent Documents Desktop My Documents 2 xl filename pw IdleRPM pyv RPMLimit pvv VEIdleRPMLimit pyv wn BL My Computer Fen ZTE e EEA Files of type Pv Tune or Value Files Cancel Places I Open as read only 3 12 WinPV User Guide WORKING WITH WINPV ks WinPV Menus is 3 Click the box next to the tune items you would like to import Or Click Mark All to select all the tune items in the list Or Click Mark Selected to place a check mark next to the tune items you have selected Or Click Clear Selected to clear all of the check boxes 4 Click OK to accept the changes Or Click Cancel to close the window Import Multiple Items f x Mark tune items to import with checkboxes then press OK to import them Idle RPM Table doesn t change and will match desired YE Front Cyl Table doesn t change and will match desired YE Rear Cyl Table doesn t change and will match desired RPM Limit Scalar didn t change 5800 More info here Clear All Mark All Mark Selected Clear Selected i 5 Click OK to complete the import
113. uning session yields learned data that reaches the upper limit of the VE table 2 Touch Scale to allow the Power Vision AutoTune feature to auto scale the necessary values in your tune to avoid reaching the maximum allowed VE values Or Touch Cap to proceed with the export and understand that some of the required corrections could not be made to your tune Or Touch Exit to exit the screen without any changes PowerYision Application Export Tune VE values over 125 were found 127 5 is the absolute maximum allowed Would you like to auto scale the max VE value down to 120 and scale Displacement up to correct this Select SCALE for auto scaling or select CAP to cap any values over 127 5 i Scale lf Cap Exit 3 Touch Continue to apply all learned values to the tune and save it to a Custom Tune slot PowerVision Application This will apply all learned values to the tune and save it to a CUSTOM TUNE slot Continue i Cancel s 4 25 Version 7 WinPV User Guide r 4 4 26 ay CHAPTER 4 Power Vision Menus Touch a slot to save the tune file Note f there is any data in the selected slot it will be overwritten Touch Select to continue with the selected slot Or Touch Cancel to abort the process Touch OK to continue A copy of the tune will be saved These are full tunes calibrations not just the values learned This is a version of the tune you started with but the VE and potential
114. with any new tune items that are possibly exposed in newer PY Firmware that the version that this tune was created with 4 new tune will be created so the original should be saved and left alone For backup Warning This may render the new tune incompatible with older Firmware revisions Be sure to save the original backup Would you like to continue To Get ECM Data from the Power Vision Get ECM Data is for diagnostic and development purposes only The files may not be needed and are not generally useful unless requested by technical support 1 Select PowerVision gt Diagnostic Test Functions gt Get ECM Data Diagnostic from PV or click the Get ECM Data button rj Get ECM Data 2 Click Yes to continue x Set ECM Data is For diagnostic and development purposes only The Files may not be needed and are not generally useful unless requested by technical support Do vou wank Fo continues 3 21 Version 7 WinPV User Guide aN CHAPTER 3 iF WinPV Menus 3 Select the diagnostic ECM data to get from the Power Vision and click OK Select Diagnostic ECM Data to get from P x 10 FB4 IMT6GH O1 stk DiagnosticsHistory kxk UPDATE Lod txt 4 Browse to the folder you want to save the diagnostic file to and click OK Browse For Folder Select Folder to Save To 9 My Received Files a E C Power vision So Diagnostics C Original Tunes gt PrintScreen Files ij _9 SolidWorks Downloads 9 SolidWo
Download Pdf Manuals
Related Search
Related Contents
Dehors les Français! Formation CV et Lettre de Motivation Belkin Screen Guard Anti-Smudge Overlay KI6501 CWDM Power Meter User Manual KT-01U 取扱説明書ダウンロード Cables Direct 2m, DB25 M/DB25 FM 5-8 functions oven user manual Copyright © All rights reserved.
Failed to retrieve file