Home
User Manual - Affordable Scales & Balances
Contents
1. 5 C 41 F 95 F 250V 1 5A 20 mm Charge Life 100 hours without backlight 48 hours with backlight Battery Recharge 12 hour Quick Charge gives 90 hours of use w o backlight 1 3 DIMENSION CTP Price Computing Scale service manual SECTION 2 KEYBOARD AND DISPLAY 2 1 KEYBAORD 0 9 Numeric keys used to enter pricing data tare weights amp i programming Clear key used to release error conditions and to clear erroneous ntries e Zero key used to manually set the zero point Tare key used to enter and clear Manual or tray Sampled tares Save key used to disable the price and tare auto clear function key reserved for future use C Speed keys these are can be programmed with tares and or unit prices These are light blue in color 2 2 DISPLAY Battery Lamp When this lamp turns ON you have about 10 hours of battery use left before you must recharge the battery Net Lamp When ON it indicates that there is a tare set and the displayed weight is a net weight Stable Lamp When ON it indicates that the weight is stable Zero Lamp Indicates that the scale is at gross zero if both Net and Zero Lamps are on then it indicates net zero Save Lamp Indicates that the auto clear feature is disabled Recharge LED Indicates various recharge states of the scale Green Scale is fully charged 100 charge Full Charge Yellow Scale is still recharging 90 99 Quick Charge Red Scale is recharg
2. Computing Scale service manual Automatic unit price clear CTP can set automatic unit price clear when return to zero ATP will clear the unit price automatically Press SAVE key will turn on off automatic unit price clear function when SAVE indicator on automatic unit price clear disable when SAVE indicator off automatic unit price clear enable SET AUTO POWER OFF CTP scale have battery detect and auto shut off function you can set this parameter Press key during self checking display shows sleep mode press Speed 4 key to select 0 4 not use auto power off turn off power after scale leisure for 1 minutes turn off power after scale leisure for 20 minutes turn off power after scale leisure for 30 minutes press Tare key to sure CTP Price Computing Scale service manual SECTION 4 APPENDIX 4 1 ERROR CODES ERR 4 Current weight exceed set zero limit thus cannot reset to zero ERR 5 Keyboard error ERR 6 Load cell not connected or Load cell damaged 4 2 NUMERIC AND ALPHABETIC CHARACTERS DISPLAYED ON LCD gt Citizen
3. Table Top Scales CTP Series Operating Manual gt Citizen SECTP E0403 CTP Price Computing Scale service manual Contents SECTION 1 INTRODUCTION 1 1 Figures 1 2 Specifications Wn 3 DIMEHSION nt see tala nee dei SECTION 2 KEYBOARD DESCRIPTIONS SECTION 3 OPERATION 3 1 General instruction 3 2 3 Overload Wal MNO AA 3 24 Unit price SCUING ars een 3 2 5 Change unit 3 3 Accumulator operation 3 3 prepare to ACCUMUlaldr aar etn arada era 3 3 2 Accumulator operation 3 90 GARROTE kea ias 3 4 PEU elai da aA 9 T15ave HE RN NCS a ea AEE ee 4 3 4 2 koad ING Unit AC ac 4 3O glazia UAC ela 5 Conoce iion RN METTE 5 30 2 AULOMaAlIG UNT DICE ce actina 6 3 5 3 AUO POWE d aN 6 SECTION 4 APPENDIR u 7 o O rehsg 7 4 2 Numeric and alphabetic characters displayed on LCD 7 CTP Price Computing Scale service manual SECTION 1 INTRODUCTION 1 1 FIGURES Large LCD display AC Rechargeable battery 4PLU Selectable reading resolution Auto backlight Tower display CTPT 1 2 SPECIFICATIONS Weight 6 Digits 999 999 max LCD Unit Price 6 Digits 9999 99 max Total Price 6 Digits 9999 99 max Product Width 320 mm 12 6 Width 320 mm 12 6 Dimensions Length 340 mm 13 4 Length 340 mm 13 4 Height 125 mm 4 5 Height 575 mm 22 6 Input 120 Volts AC 60 Hz AC Adapter Output 9 Volts DC 800mA Positive Tip Operating Temp 5 C 3
4. ing 0 89 Must keep charging O f LED is Off the scale is running on battery power CTP Price Computing Scale service manual SECTION 3 OPERATION 3 1 INSTALL Pole Display CTPT model scales require assembly of the pole display Insert the pole into the display bracket rear of scale and slide it down until it is securely fastened Platter Assembly Place the ABS plastic platform on the scale Then place the stainless steel platter on top Initial Setup Plug the AC adapter into the scale amp then into an AC outlet The adapter plugs underneath the right side of the scale next to the power switch Power Switch The power switch must be held down for more than one second for the scale to turn ON 3 2 BASIC OPERATION 3 2 1 BEFORE OPERATION Make sure the platter is sitting properly on top of the platform and that there is nothing on top of the platter Also make sure that the scale is plugged into the proper outlet Hold down the power switch until the scale displays run through a self test count down to zero and then beep This is the Initial State and displays appear like this 3 2 2 Weighing il Enter a unit price using the numeric keys 2 Place an item on the platter 3 Hemove the item from the platter Steps 1 amp 2 can be interchanged After step 2 you will notice that the Total Price display will show the calculated Total Price For example After step 3 you will notice that the displa
5. rice displays from auto clearing 3 3 PROGRAMMING PLUS WITH THE SPEED KEYS 1 Enter a tare if desired 2 Enter a Unit Price if desired 3 Press and hold down any of the 4 Speed Keys until the Total Price display shows Saved and the scale will give a long beep For example if you want to program Speed key 1 with a Unit Price of 1 00 but without a tare simply 1 Make sure that you are at the initial state 2 Pres 1 0 and O 3 Press amp hold down Speed Key 1 until displays show 3 4 CHARGING THE BATTERY The BATT Lamp is located on the bottom left side of the Weight display When it turns ON you will see an arrowhead Y pointing to BATT When this happens you need to recharge the battery The scale can be ON or OFF when recharging so long as it is plugged into the AC adapter The Recharge LED is located on the bottom right side of the Total Price display and has various states which are explained on the other side of this guide An overnight charge of 12 hours will give you approximately a 9096 charge or about 90 hours of continuous no backlight use 3 5 OTHER FUNCTION 3 5 1BACKLIGHT SETTING The backlight can operate in 3 different modes Always ON OFF or AUTO which turns the backlight on when the scale is in use To change this feature 1 Hold down SAVE key amp release it once you hear 2 beep 2 Press Speed Key 4 to select on oFF or Auto Press the TARE key to save the setting 3 5 2 3 5 3 CTP Price
6. ys will return to there initial state of 0 00 CTP Price Computing Scale service manual 3 2 3 Weighing Using Known Tares 1 Enter a tare weight using the numeric keys Press TARE Enter a unit price using the numeric keys Place an item on the platter al e cUm Je Remove the item from the platter Steps 3 and 4 can be interchanged Once you press the TARE key you will notice that the NET light will come on indicating to you that the weight shown is a net weight For example After step 5 you will notice that the displays will return to there initial state of 0 00 3 2 4 Weighing Using Unknown Tares 1 Place the empty container on the platter 2 Press TARE 3 Enter a unit price using the numeric keys 4 Place an item on the platter 5 Remove the item from the platter Steps 3 and 4 can be interchanged Once you press the TARE key you will notice that the NET light will come on indicating to you that the weight shown is a net weight 3 2 5 Weighing Using the Speed Keys 1 Press the Speed key on the keyboard and change the price if desired 2 Place an item on the platter 3 Remove the item from the platter Steps 1 and 2 can be interchanged You can learn how to program the Speed Keys in the next section CTP Price Computing Scale service manual 3 2 6 Using the Save Key amp the Auto Clear Feature If you press the SAVE key before any operation the SAVE Lamp will come on This will prevent the Weight and Unit P