1. When set press key to save setting and continue Notes for Display Value Offset 1 fcontroller is set for degrees C display this offset value remains in units of F 2 Positive values will offset the Displayed value higher 3 Negative values will offset the Displayed value lower L22 320 Rev 1 06 11 Page 6 of 12 Pitco Solstice Digital Controller 4 Default values APL1 gas 2 F APL2 electric 3 F APL3 general use thermostat OF 4 7 Exit Programming Press the key to return to normal displays d 0A HEARN E9 EA 50 F Ready to Cook Heating up to Melt Cycle Temperature Below drop conditions in progress 150 5 Other Displays 5 1 Low VatTemperature When tank temperature is below 150 F 66 C the display will show as blanks This is normal for cold start ups Heat Demand indicator is located between the first and second digits of display HEAT INDICATOR 5 2 Drain Valve Open When drain valve is detected open normal operations are suspended The display will show Drain Turn Off message until reset To reset CLOSE the drain valve turn the control OFF Some applications do not use the drain valve input E LJ m N 5 3 Equipment Fault Displays This control will detect faulty probe conditions If temperature probe H faults are detected display will show one of two possible conditions All other functions are disabled To reset turn control Off then On OPEN PROB
2. e IMPORTANT FOR FUTURE REFERENCE 7 CO Please complete this information and retain this manual for the life of the equipment Model Serial Service Manual Covering Pitco Solstice Digital Controller Pitco p n 60126601 Pitco ao 0 L22 320 Rev 1 06 11 Pitco Solstice Digital Controller 1 KEYPAD AND DISPLAY FUNCTIONS ssseseessssssseeeseessseessessesesseeeeeees 3 2 NORMAL OPERATIONS FOR THE OPERATOR cccceeeeeeeeeeeeeeeeeeeeeeeeeeeeees 3 2 1 To turn control ON scccecsssssessccsecscsscssseessssnseesecscesesssnscessnessssnescessessessessnesessnessessessessessessossessossoesses 3 2 2 To turn control OFF ossessi sensitisation Ee nS Es Oe EAEn E S E noo non SESO S Eas 3 2 3 To Start a Cook AAA 3 2 4 To Cancel a Cook Time s ssccsssscsscseesssssssscsssscescsssnscsssnsssssnsscessessessessnessssnessessessessessessossossosssesees 3 2 5 To Display Vat Temperature and Set Temperatures csccsssssssssscsscsscescsssssssesesenesssssessessossesees 3 3 TO ENTER PROGRAMMING FOR THE STORE MANAGER ccsseeeeeeees 4 3 1 A O AO 4 3 2 NR O O 4 3 3 To Change Cook Temperature s sesseesesoessesessoesessossesocssesoesoesessesessoesessossesoessesoesossessossessossesoesessssssesesss 4 3 4 To Change Melt Cycle types siccsscsssccssssecestcsovascosecussassesesscoessoes cedo susccenssesseniscnssenaestasonsscasecucstnesaessasenesseens 4 3 5 To Change Pass Wo
3. 4 To Enter Level 2 programming from TECH Display for technicians and factory use Follow the instructions beginning at section 3 Use the key to advance to the Tech display With display showing F a H from step 3 7 above press the key AND the key simultaneously for 3 seconds and continue 41 Standing Pilot The display now shows current setting for the Standing Pilot option SP ODHSP If Where 0 OFF and 1 ON Press 9 the UP arrow key or DOWN arrow key to change this setting When set press key to save setting and continue Note Standing Pilot has no effect if ApplianceType 2 electric is selected in sect 4 4 4 2 Number of Basket Lifts Display shows current basket lift setting or F Ifo FA l Where LiFO is no basket lift outputs LiF1 is left basket lift and LiF2 is both left and right outputs are active Press the UP arrow key or DOWN es g arrow key to change setting When set press key to save setting and continue L22 320 Rev 1 06 11 Page 5 of 12 Pitco Solstice Digital Controller 43 Display Options Display Vat temperature may be displayed rather than the normal displays Display En shows OR E Press the UP arrow key or DOWN arrow key to change setting When set press key to save setting and continue Tech Tip This display mode is intended as an aid to troubleshooting fryer performance This setting should always be returned to the t 0 setting after use 44 Applian
4. 450 232 2 336 29 125 51 7 30902 290 143 3 1977 3 455 235 0 321 21 130 54 4 27862 295 146 1 1851 0 460 237 8 306 94 135 57 2 25161 300 148 9 1734 3 465 240 6 293 46 140 60 0 22755 305 151 7 1626 1 470 243 3 280 69 145 62 8 20610 310 154 4 1525 9 475 246 1 268 61 150 65 6 18695 315 157 2 1433 0 480 248 9 257 15 155 68 3 16981 320 160 0 1346 7 485 251 7 246 30 160 71 1 15446 325 162 8 1266 6 490 254 4 236 00 165 73 9 14069 330 165 6 1192 1 495 257 2 226 24 170 76 7 12823 335 168 3 1122 8 500 260 0 216 96 8 Probe Resistance Chart Notes Resistance of either probe lead to the frame of the appliance should read as open on the meter Typically this is 1Meg ohms or more L22 320 Rev 1 06 11 Page 11 of 12 In the event of problems with or questions about your order please contact the Pitco Frialator factory at 603 225 6684 World Wide www pitco com In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area or contact Pitco at the numbers listed to the left MAILING ADDRESS P O BOX 501 CONCORD NH 03302 0501 SHIPPING ADDRESS 10 FERRY ST CONCORD NH 03301 L22 320 Rev 1 06 11 Page 12 of 12
5. E SHORTED PROBE OR HIGH TEMP ALARM 5 4 Fill Display If this appliance is equiped with a liquid level option the control will F E a display FiLL when the water level gets to low Heat is suspended while the tank is filling or toping off Some appliances don t have the liquid level option L22 320 Rev 1 06 11 Page 7 of 12 Pitco Solstice Digital Controller 5 5 Heat Failure This message indicates that the heating system failed to respond to the BE H F H E controls demand for heat Typically the high temperature limit switch has tripped and is need of resetting In the case of gas fired appliances this message will display if the pilot fails to light or is F a a detected marginal by the ignition module L22 320 Rev 1 06 11 Page 8 of 12 Pitco Solstice Digital Controller 6 Mechanical Dimensions MAXIMUM COMPONENT HEIGHT 1 650 AMP 641973 1 OR EQUIVALENT TE A 14 750 2X NOTCHES 28W X 09D 4X NOTCHES 25W X 25D FACEPLATE SHOWN WITH OVERLAY A6083201 Rito PE T Enoalotor PHANTOM KEY L22 320 Rev 1 06 11 Page 9 of 12 Pitco Solstice Digital Controller 7 Electrical Connections at 1 Ji Imputs Type Nominal ____Notes ____ 24VAC 24VAC 20 15 50 60Hz 24VACN__ 24VAC Return 3 a pene feason a Mrorae EO Proble__ 350 F 6 HFB CIN 24VAC_ HeatFeedBack 8 HD jour 24VDC_HeatDemand 9 SOFER OUT 24VDC_ SideONorXFER_
6. ___ a N CI DE E NO Se DA ERSA LJ L22 320 Rev 1 06 11 Page 10 of 12 Pitco Solstice Digital Controller Probe Resistance in 5 F Increments Probe Probe Probe Probe Probe Probe Temp Temp Resistance Temp Temp Resistance Temp Temp Resistance F C Ohms F C Ohms F C Ohms 10 12 2 562734 175 79 4 11719 340 171 1 1058 23 15 9 4 483875 180 82 2 10716 345 173 9 998 09 20 6 7 417167 185 85 0 9812 350 176 7 942 00 25 3 9 360589 190 87 8 8995 355 179 4 889 67 30 1 1 312474 195 90 6 8255 360 182 2 840 78 35 1 7 271446 200 93 3 7586 365 185 0 795 10 40 4 4 236370 205 96 1 6979 370 187 8 752 38 45 7 2 206311 210 98 9 6427 375 190 6 712 41 50 10 0 180491 215 101 7 5926 380 193 3 674 95 55 12 8 158252 220 104 4 5470 385 196 1 639 87 60 15 6 139055 225 107 2 5055 390 198 9 606 96 65 18 3 122489 230 110 0 4675 395 201 7 576 09 70 21 1 108051 235 112 8 4329 400 204 4 547 09 75 23 9 95539 240 115 6 4013 405 207 2 519 86 80 26 7 84644 245 118 3 3723M 410 210 0 494 24 85 29 4 75136 250 121 1 3458 415 212 8 470 16 90 32 2 66823 255 123 9 3214 420 215 6 447 49 95 35 0 59540 260 126 7 2991 425 218 3 426 13 100 37 8 53146 265 129 4 2785 430 221 1 406 02 105 40 6 47523 270 132 2 2597 435 223 9 387 04 110 43 3 42569 275 135 0 2422 440 226 7 369 14 115 46 1 38195 280 137 8 2262 445 229 4 352 24 120 48 9 34328 285 140 6 2113 9
7. ce Type E APT is for ADTs LS Gas 1 ADTs or general use Thermostat 3 on DOWN arrow key to change setting When set press key to save setting and continue 4 5 Control Point Offset This adjustment allows the control point to be adjusted to account for differences between probe tip temperature and vat center oil temperature The adjustment range is plus or minus 0 15 F Negative values are preceded with a minus sign in display Press the UP arrow key or DOWN arrow key to change setting When set press key to save setting and continue ia Notes for Control Point Offset 1 f controller is set for degrees C display this offset value remains in units of F 2 Positive values will offset the vat control point temperature higher 3 Negative values will offset the vat control point temperature lower 4 Default values APL1 gas 2 F APL2 electric 3 F APL3 general use thermostat OF 5 Warning Proper equipment and expertise is required to properly adjust this value Even small changes may negatively effect cooking performance 4 6 Display Value Offset This adjustment allows the Displayed Value for temperature to be adjusted to account for differences between probe tip temperature and set point temperature The adjustment range is_plus or minus 0 15 F Negative values are preceded with a minus sign in display l Press the UP arrow key or DOWN arrow key to change setting oR
8. rd Requirement s sessossesoosseseosoesessossesoessescesoesessossesoesessossesoessesoesoesessossessossoesesss 4 3 6 To Change SF OF C AAA TO 5 3 7 To exit Level 1 Programming senesinin ennes ronie aisa oaie i e N ii eiiean 5 4 TO ENTER LEVEL 2 PROGRAMMING FROM TECH DISPLAY FOR TECHNICIANS AND FACTORY USE iiiicccncicicsccciics cad ERRE 5 Standing Pilot viescsiscciscsccddscdsetensinsecssoossuscevecseccsvacswasovsedassesveshconsoessosesedendoaseedesoasdedheonsegsouasbes seus oseedessenassesooveeseassbastes 5 4 2 Number of Basket Lifts sscsssssscsssssssssssssssssscsscssssscsssnssssssessesssssescsssnessssnessessessessessessesssssossoesoes 5 4 3 Display Options Display scccccccscscscssscscscscscscsccssscssscsssescsncssnesceessccssessscssscsssssesssscsssssssscsssescessoess 6 4 4 NN NO 6 4 5 Control Point Offset ocnonoonconoononnnonocinonncnnconcnnonncononononccnnoncn nono co nono nonconnconcn corno nono rocccc roo nonccn nro non con co conoce 6 4 6 Display Value Offset onoonoononnconoononnconoconcononnconcnnonoconoconoonononnncononnconcn nono ronoco noo non oo Ssns Sooo rooi sossut Sorosi 6 4 7 Exit Programming mocconconoononnoonoononnconocanonncnnooncnnonn conoce nonncononcnnonn conoce nooncn noo ncn nooo ro ooe ges cess rco non totei soene ro nos 7 5 OTHER DISPLA VS AAA AAA err rrr pre 7 5 1 Low Vat Temperature cccssccsccscscssscsssnsssssscscescsssnscessnessssnescessessssossnessssnessesscs
9. s the Basket key until light above the key is off 2 5 To Display Vat Temperature and Set Temperature Press the temperatu Press the temperatu Press the re pisplay Shows key once Display will show current VAT Scale re 348 F 176 C in this example J y H F or C Scale key again Display now shows the SET l 7 5 T LO Jro or make no key presses for 5 seconds and display will return to one of the romaans OA HERN eE E H Ready to Cook Heating up to Melt Cycle Temperature Below drop conditions in progress L22 320 Rev 1 06 11 Page 3 of 12 Pitco Solstice Digital Controller 3 3 1 3 2 3 3 3 4 3 5 To Enter Programming for the store manager Press key If the display shows ee press Y to unlock and continue To set timer T1 The indicator light above timer key 1 will illuminate Display will show current timer setting in MM SS format for this key Press the UP arrow key or DOWN arrow key to adjust timer value The value will change in steps of 5second each When set press key to save setting and continue To set timer T2 The indicator light above timer key 2 will illuminate Display will show current timer setting in MM SS format for this key Press the UP arrow key or DOWN arrow key to adjust timer value The value will change in steps of 5second each When set press key to save setting and continue de To Change Cook Temperature Display will sho
10. sessosscssosssssossoeses 7 5 2 Drain Valve AAA 7 5 3 Equipment Fault Displays ccsssssscssssscsscssseccescssssscsssnesscsscscessessescessnessssnessessessesssssessosssssossoosoes 7 5 4 NR RN 7 5 5 Heat ET N a AE T TE E T A TE E OR E ITI EE OIE OE EAE TIE 8 6 MECHANICAL DIMENSIONS eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 9 7 ELECTRICAL CONNECTIONS AT U1 cccccccceseeseeeeeeeseeeeeeeeeeeeeeeseseesssseesssesseeeess 10 8 PROBE RESISTANCE CHART ixiiccsicscateiedcckeietieveadacketeretckeateeaaens 11 L22 320 Rev 1 06 11 Page 2 of 12 Pitco Solstice Digital Controller 1 Keypad and Display Functions TIME OR STATUS DISPLAY HEAT INDICATOR PROGRAM ON OFF KEY A TEMPERATURE INDICATORS VIEW KEY 2 TIMER KEYS UP AND DOWN ADJUST KEYS 2 Normal Operations for the operator 2 1 To turn control ON Press oO Display will momentarily show the current Appliance Type APLx for 2 seconds and then to one of the normal displays shown here 4 0A HEAN E3 E H Ready to Cook displayed Heating up to Melt Cycle Temperature Below drop conditions in progress 2 2 To turn control OFF Press and hold for 3 seconds Display will show oF Fl 2 3 To Starta Cook Timer When display shows droP press a basket key to start a cook timer Both P P timers may run together Only the timer with the least time remaining will be OR 2 4 To Cancel a Cook Timer Pres
11. w xxx F or xxx C the current temperature setting The default setting is 350 F 1770 Press and hold the UP arrow key or DOWN arrow key to scroll temperature setting A single key press will increment or decrement the m 5 setting by one degree When set press key to save setting and continue To Change Melt Cycle type Display now shows the current melt cycle setting Solid Liquid No Melt Cycle Press the UP arrow key or DOWN arrow key to adjust melt cycle type a When set press key to save setting and continue To Change Pass Word Requirement lLoLl Lol Display will show the current lock sal Lo E an O Unlocked Locked Press the UP arrow key or DOWN arrow key to change lock setting for ig future entry into programming menus When set press key to save setting and continue L22 320 Rev 1 06 11 Page 4 of 12 d Pitco Solstice Digital Controller 3 6 To Change F or C Display Display will show the current temperature scale setting eiter Farenheit or Celcius Press the UP arrow key or DOWN arrow key to change lock setting for oR future entry into programming menus VJ When set press key to save setting and continue 3 7 To exit Level 1 Programming Display is showing F E H Press key to exit here The display will return to one of the normal operating displays d OPA HEAN C3 E_F Ready to Cook Heating up to Melt Cycle Temperature Below drop conditions in progress 150