1. El Manual Page 5 Regeneration and Error Screens 3 Remaining M La M Days Regen Screen Backwash Displays the time remaining in the Draw current cycle Pressing REGEN Rinse advances to the next cycle Fill a Error Screen l J J Alternated flashing Err and error code every 3 seconds Clear by 4 4 dissconnecting the power supply at the PC board and reconneting or press the NEXT and REGEN buttons simutaneously for 3 seconds A EE T L ba m AS m SZ Button Operation and Function NEXT Scrolls to the next display Pressing once and releasing will schedule a regeneration at the preset delayed regeneration time Pressing again and releasing will cancel the regeneration REGEN Pressing and holding for 3 seconds will initiate an immediate regeneration Pressing while in regeneration will advance to the next cycle Pressing in the program levels will go backwards to the previous screen A Changes variable being displayed Key sequence to lock and unlock Holding for 3 seconds intitiates a control reset The software NEXT REGEN version is displayed and the piston returns to the home service position resynchronizing the valve Page 6 General Operation Remaining M I M Days Set Backwash Total Draw X 1000 Rinse Regen Fill NEXT V REGEN Remaining M Hour M Days Sa Set Backwash Total Draw X 1000 Rinse Regen Fill next A
2. return to previous step Page 8 El Manual 7 Day or 7 Volume MP selected in Configuration Settings Step 3CS N REGEN Remaining M Mou M Days i Set Backwash Total Draw X 1000 Rinse Regen Fill DEN e AlV Remaining M eur a M Days Set Backwash Total Draw X 1000 v7 Regen EY per A V Rinse Fill RemainingM Mou M Days Backwash Draw Rinse Fill Remaining M Hour M Days Backwash Draw Rinse Fill Step 11 To enter Installer Display press the NEXT and A buttons simultaneously for 5 seconds and release Step 21 Use A or Y buttons to set the current day of the week Default 2 Monday 1 ZSUNDAY 2 MONDAY 3 TUESDAY 4 WEDNESDAY 5 THURSDAY 6 FRIDAY 7 SATURDAY Press NEXT to go to Step 31 Press REGEN to exit Installer Display Step 31 Scroll through days 1 to 7 using the NEXT button Use the A or Y buttons to turn regen on or off for each individual day regen indicator on means regeneration will happen After completing the 7th day press NEXT to go to Step 4I Press REGEN to go to previous display Step 4I Use the A or Y buttons to set the regen hour Press NEXT to go to Step 5I Press REGEN to go to previous display Step 5I Use the A or V buttons to set the regen minutes Press NEXT to
3. Motorized Alternator Valve MAV is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board The A port of the MAV must be plugged and the valve outlet connected to the B port The MAV will be driven closed before the first regeneration cycle that is not FILL or SOFTENING or FILTERING and be driven open after the last regeneration cycle that is not FILL NOTE If the control valve is in an error state during regeneration mode the no hard water bypass valve will remain closed until the error is corrected and reset 1 5 3 Way MAV 2 MAV Old Style MAV and REV 2 New Style Configuring the Control Valve for Separate Source Backwash Operation During programming nHbP must be selected This selection requires that a connection from a Clack Motorized Alternator Valve MAV is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board The Common port of the MAV must be connected to the inlet of the control valve The A port will become the inlet for the separate source backwash water supply The B port will become the inlet for the untreated water supply The MAV will be driven closed before the first regeneration cycle that is not FILL or SOFTENING or FILTERING and be driven open after the last regeneration cycle that is not FILL NOTE If the control valve is in an error state during regeneration mode the 3 Way MAV Motorized Alternator Valve will close the B port and keep ope
4. 50 during programming If a WS2L valve is being used with newer version software that has both 50 and 50L selection choices the valve must be set for 50L during programming El Manual Remaining M THOU re M Days Set 4 Backwash Total n Draw X 1000 l D Rinse Regen Fi A V REGEN NEXT di Page 11 Step 5CS Allows selection of one of the following the Control Valve to act as an alternator or Remaining M Hour_ M Days 9 Time the Control Valve to have no hard water bypass se lt q S T Backwash x 3000 r E Selecting the Control Valve to act as an alternator Regen REPRESENT Fil NOTE In step 3CS you must select Volume Step 4CS WENT A V REGEN select Regeneration Time Option on 0 and in Step 3I select Day Override oFF Select oFF when feature not used Select ALTA for the control valve that has the two pin connector labeled DRIVE connected to the alternator valve motor Select ALTb for the control valve that will not be connected to the alternator valve motor 1 1 25 2 Way MAV FF or FM Configuring the Control Valve for No Hard Water Bypass Operation nHbP Selection requires that a connection from a Clack Motorized No Hard Water Bypass Valve NHBP is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board The A port of the NHBP must be connected to the outlet of the contr
5. Hour e M Days Set l Backwash Total Draw X 1000 Rinse Regen gt Fill next A W REGEN Step 3CS Remaining M ei M Days Set lt q ME Backwash Total Draw X 1000 Rinse Regen lt q Fill next N AZ REGEN Remaining M Hout M Days Backwash Draw Rinse Fill REGEN El Manual Configuration Settings Step 1CS Press A and Y buttons simultaneously for 5 seconds and release If screen in Step 2CS does not appear the lock on the valve is activated To unlock press W NEXT REGEN A in sequence then press A and W buttons simultaneously for 5 seconds and release Step 2CS Select 25 for 1 25 mm 32 for 1 25 32 mm 38 for 1 5 38 mm 50L for 2L 50mm or 50 for 2 50mm Press NEXT to go to Step 3CS Press REGEN to exit Configuration Settings Step 3CS Press the A or Y buttons to select one of the following f Volume M is selected the regeneration will occur after the specific volume has been used or on the day override if selected whichever comes first f 28 is selected the regeneration will occur on the day 1 through 28 selected in Installer Display Settings The total flow and flow rate user displays and the volume display in Diagnostics will not be shown even if a meter is used f 28 Volume M is selected the regeneration will occur on the day 1 through 28 selected in Installer Display Settings If a meter is not used the total flow and flow rate
6. Ld If the dP switch is closed a regeneration will be prevented from occurring Not viewed if Step 5CS is set to ALTA or ALTb Press NEXT to exit Configuration Settings Press REGEN to return to previous step El Manual Page 13 Alternator Programming Guide The following instruction must be followed when programming the WS1EI WS2EI as an alternator Valve A 1 In Configuration Settings Step 3CS VOLUME M3 must be selected 2 In Configuration Settings Step 4CS On 0 must be selected 3 In Configuration Settings Step 5CS Alt A must be selected The A control is the one connected to the A port of the MAV Motorized Alternating Valve and has the two pin wire connector from the MAV Motorized Alternating Valve connected to it 4 In Volume Installer Display Settings Step 2I enter the volumetric capacity for the system 5 In Volume Installer Display Settings Step 3I set Days Override to OFF Valve B 1 In Configuration Settings Step 3CS VOLUME M3 must be selected 2 In Configuration Settings Step 4CS On 0 must be selected 3 In Configuration Settings Step 5CS Alt B must be selected The B control will be connected to the B port of the MAV Motorized Alternating Valve and will have no electrical connection to the MAV 4 In Volume Installer Display Settings Step 2I enter the volumetric capacity for the system This must be the same as Valve A 5 In Volume Installer Display Settings Step 3I set Day
7. REGEN Remaining M Hour M Days Time Set E Backwash Total GUC Draw X 1000 Rinse Regen Fill wer A V ee RemainingM e M Days Set Backwash Total lt q g 198 Draw X 1000 Rinse Regen n Fill next A Y REGEN Remaining M Hour M Days Set Backwash Total Draw X 1000 mul Rinse Regen Fill next V REGEN Remaining M Mout M Days Backwash set lt q TT Total Draw X 1000 A Rinse Regen Fill HINA Per TA V ems El Manual User Displays When the system is operating one of five displays may be shown Pressing NEXT will alternate between the displays shown below User 1 Typical user display If volume is selected in Configuration Settings Step 3CS shows volume remaining to regeneration If volume is not selected in Configuration Settings Step 3CS this screen will not be shown If a meter is not used this display will not change User 2 Displays number of days to next regeneration User 3 Displays flow rate M Hour If a meter is not used this display will be shown but 0 will be displayed User 4 Displays total flow in cubic meters since last reset If a meter is not used this display will be shown but 0 will be displayed PRESS THE DOWN W ARROW FOR 3 SECONDS TO RESET TO 0 User 5 Shows current time Setting Time of Day Push NEXT button until time of day screen is displayed Press and hold the A arrow until the SET indicator is dis
8. Water Specialist El Control Valve Programming and Cover Drawing Manual Page 2 El Manual El Manual Page 3 Table of Contents El Front Cover and Drive Assembly 3 retire trt dde 4 Repeneration and Error Screens ci ies 5 MY SE TDI IAS EE 6 Installer Dis play Settings eie ret DER ot J Setting Regeneration Cycle Times inisesin n a e TG 9 Configurations Seto oi 10 Alternator Programming Guide iia a iii 13 DIAENOSUCH a M CE 14 Page 4 El Manual EI Front Cover and Drive Assembly Drawing No Order No Description Quantity I V3175EI 01 WS1El FRONT COVER ASSEMBLY 1 2 V3107 01 WS1 MOTOR 1 3 V3106 01 WS1 DRIVE BRACKET amp SPRING CLIP I 4 V3408EI 02BOARD WSITHRU2L EI PCBRD MAV ALT REPL 1 5 V3110 WS1 DRIVE REDUCING GEAR 12X36 3 6 V3109 WS1 DRIVE GEAR COVER 1 V3186 WS1 AC ADAPTER 110V 12V Not Shown V3186EU WS1 AC ADAPTER 220 240V 12V EU i V3186UK WS1 AC ADAPTER 220 240V 12V UK V3186 01 WS1 AC ADAPTER CORD ONLY Not Shown V3178 WS1 Drive Back Plate 1 Refer to Control Valve Service Manual for other drawings and part numbers AC Adapter US International Supply Voltage 120 V AC 230V AC Supply Frequency 60 Hz 50 Hz Output Voltage 12 V AC 12 V AC Output Current 500 mA 500 mA positives and push down to fully seat Correct FK N Battery replacement is Battery 3 volt lithium coin cell Orienta type 2032 tion d d
9. ed this display will read 0 Press NEXT to go to Step 4D Press REGEN to return to previous step Step 4D Display shows the days in service since start up Press NEXT to go to Step 5D Press REGEN to return to previous step Step 5D Display shows the total number of regeneration cycles since start up Press NEXT to exit Diagnostics Press REGEN to return to previous step El Manual Page 15 Page 16 El Manual Revision History 5 29 08 Moved common valve drawings to V3435 WS1 5 2L Drawing and Service Manual 7 08 08 a gt ep Ej oc Added Softening or Filtering selection Step 2CT PAGE 9 Added 32mm option Step 2CS PAGE 8 Added special Rinse cycle Step 2CT 8 01 08 ro gt ep e a Updated display for Step2I PAGE 7 Updated display for Step2I and Step3I PAGE 8 Updated display for Step2CT PAGE 9 Step2CS Select 25 for 1 25 mm 32 for 1 25 32 mm 38 for 1 5 38 mm 50L for 2L 50mm or 50 for 2 50mm PAGE 10 Updated display for Step7CS 10 13 08 V gt e ej ji Revised No Hard Water Bypass instructions PAGE 12 Added MAV instructions 1 5 2009 az gt ep E Un Ne Updated the instructions for Step 7CT Form No V3435El 1 5 2009
10. exit Installer Display Press REGEN to return to previous display El Manual next N REGEN ining M Hour M Remaining Time Days Set p uo i raneein Backwash Total Draw X1000 Rinse Regen Fill EELLLLLL NN NNNM NEXT REGEN aly Remaining M Mou e M Days Set lt q D gt Backwash Total Draw X 1000 Rinse Regen Fill next REGEN Step 4CT Remaining M Hour M Days Time AAAA ZALI Set lt Backwash Total D Draw X 1000 Rinse Regen Fill FETENNNN N V REGEN Remaining M Hours M Set gj D gt Backwash Total Draw X 1000 Rinse Regen Fill NN NEXT A REGEN Days JH M Hour Time M Set lt Backwash Total Draw X 1000 D gt Rinse Regen Fill VIN NEXT REGEN A IV Remaining Days i 3 Remaining M Mour re M Days Set lt AA Total X 1000 Regen BE EXIT TO DISPLAY SCREENS PTTTNNNAN Page 9 Setting Regeneration Cycle Times Step ICT Press NEXT and Y simultaneously for 5 seconds and release If screen in Step 2CT does not appear the lock on the valve is activated To unlock press Y NEXT REGEN A in sequence then press NEXT and Y simultaneously for 5 seconds and release Step 2CT Select between SOFTENING or FILTERING When set to FLTr 7CT is not se
11. n the A port until the error is corrected and reset Press NEXT to go to Step 6CS Press REGEN to return to previous step Page 12 Step 6CS ining M Hour M Remaining Time Days Set al er Backwash Total suso Draw X1000 le Rinse Regen NSS Fill N WV REGEN Remaining M our M Days Remaining M Iowa M Days Set lt q Backwash 4 Set lt q gt Backwash Total Draw Total _ E J Draw X 1000 Rinse X 1000 j Rinse Regen zi Regen PELLLNNNNN Fi next A recen next A V REGEN EXIT TO DISPLAY SCREENS El Manual Step 6CS Set duration of the special rinse cycle to be performed prior to a valve returning to Service Selectable from 1 20 minutes or OFF Only viewed if 50 is set in 2CS and ALTA or ALTb is set in 5CS Press NEXT to go to Step 7CS Press REGEN to return to previous step Step 7CS Selecting the use of an outside signal to initiate a regeneration Selection only matters if a connection is made to the two pin connector labeled DP SWITCH located on the printed circuit board Following is an explanation of the options oFF feature not used on0 If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur immediately dELy If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur at the scheduled regeneration time Ho
12. ol valve The NHBP will be driven closed before the first regeneration cycle that is not FILL or SOFTENING or FILTERING and be driven open after the last regeneration cycle that is not FILL NOTE If the control valve is in an error state during regeneration mode the no hard water bypass valve will remain closed until the error is corrected and reset 1 1 25 3 Way MAV FF or FM Configuring the Control Valve for Separate Source Backwash Operation During programming nHbP must be selected This selection requires that a connection from a Clack Motorized Alternator Valve MAV is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board The Common port of the MAV must be connected to the inlet of the control valve The A port will become the inlet for the separate source backwash water supply The B port will become the inlet for the untreated water supply The MAV will be driven closed before the first regeneration cycle that is not FILL or SOFTENING or FILTERING and be driven open after the last regeneration cycle that is not FILL NOTE If the control valve is in an error state during regeneration mode the 3 Way MAV Motorized Alternator Valve will close the B port and keep open the A port until the error is corrected and reset 1 5 MAV 2 MAV Old Style MAV and REV 2 New Style Configuring the Control Valve for No Hard Water Bypass Operation nHbP Selection requires that a connection from a Clack
13. played and the hour flashes Press the A or Y arrow until the correct hour is displayed Then press the NEXT button The minutes will flash Press the A or V arrow until the correct minute is displayed Press the NEXT button to return to the Display Screens Time of day should only need to be set after power outages lasting more than 8 hours if the battery has been depleted and a power outage occurs or when daylight saving time begins or ends If a power outage lasting more than 8 hours occurs the time of day will flash on and off which indicates the time of day should be reset If a power outage lasts less than 8 hours and the time of day flashes on and off the time of day should be reset and the battery replaced El Manual Page 7 Installer Display Settings One of three sets of displays will be shown depending on what was selected in Configuration Settings Step 3CS Volume M selected in Configuration Settings Step 3CS REGEN Backwash Draw Rinse Fill REGEN Step 31 Remaining M enr M Days A M Hour Remaining Time Fr Step 5I Remaining M Mei io M Days Backwash Draw EXIT TO i Rinse DISPLAY Regen e qim ri SCREENS REGEN Step 11 To enter Installer Display press the NEXT and A buttons simultaneously for 5 seconds and release Step 2I Volumetric capaci
14. s Override to OFF Page 14 Step 1D N V REGEN N WV REGEN Step 2D Remaining M Hour Days M Time Set Tu Backwash Total lt lt Draw X 1000 Rinse Regen lt q Fill next REGEN Remaining M Ho M Days Set Backwash Total lt Draw X 1000 Rinse Regen d Fill next A REGEN Step 4D Remaining M Ho M Days Set Backwash Total lt Draw X 1000 Rinse Regen Fill next V REGEN Step 5D Remaining M Mon M Days Set Backwash Total lt Draw X 1000 Rinse Regen d Fill De A TV Tem EXIT TO DISPLAY SCREENS El Manual Diagnostics Step 1D Press A and V buttons simultaneously for 5 seconds and release Then press A and Y buttons simultaneously for 2 seconds and release If screen in Step 2D does not appear the lock on the valve is activated To unlock press NEXT REGEN A in sequence then press A and Y buttons simultaneously for 5 seconds and release Then press A and Y buttons simultaneously for 2 seconds and release Step 2D Display shows the number of days since a regeneration last occurred Press NEXT to go to Step 3D Press REGEN to exit Diagnostics Step 3D Display shows the volume of water treated in MP treated since the last regeneration If Volume M 28 Volume MP or 7 Volume M was selected in Step 3CS and no meter is install
15. t to oFF and 2CS is set to 25 a fixed 30 second Backwash is automatically added to the regen cycle program after Rinse 6CT The status display for this extra backwash will appear as just another cycle step in sequence Press NEXT to go to Step 3CT Press REGEN to exit Regeneration Cycle Times Step 3CT Adjust the length of the backwash from 1 20 minutes or OFF using the A or Y buttons Press NEXT to go to Step 4CT Press REGEN to return to previous step Step 4CT Adjust the length of the regenerant draw from 1 99 minutes or OFF using the A or Y buttons Press NEXT to go to Step SCT Press REGEN to return to previous step Step 5CT Adjust the length of the second backwash from 1 20 minutes or OFF using the A or Y buttons Press NEXT to go to Step 6CT Press REGEN to return to previous step Step 6CT Adjust the length of rinse from 1 20 minutes or OFF using the A or Y buttons Press NEXT to go to Step 7CT Press REGEN to return to previous step Step 7CT Adjust the length of fill from 0 1 99 9 minutes or OFF WS2 valves are shipped from the factory with a refill flow control of 2 2 gpm 8 3 Ipm All other control valves are shipped from the factory with a refill flow control of 0 5 gpm 1 9 Ipm Press NEXT to exit Regeneration Cycle Times Press REGEN to return to previous step Page 10 V REGEN b NEXT Remaining M i
16. ty in cubic meters to regeneration Press NEXT to go to Step 3I Press REGEN to exit Installer Display Step 3I Adjust day override from 1 28 or OFF Press NEXT to go to Step 4I Press REGEN to return to previous step Step 4I Use A or Y buttons to set the regen hour Press NEXT to go to Step 5I Press REGEN to return to the previous step Step 5I Use A or Y buttons to set the regen minutes Press NEXT to exit Installer Display Press REGEN to return to previous step 28 Day or 28 Volume M selected in Configuration Settings Step 3CS next N REGEN Remaining M Hour re M Days Set lt lt d Backwash Total X 1000 Regen lt FENN y vet A V Remaining M Tour s M Days VT lt Backwash 7 Draw g Rinse a Fill DEN N V REGEN Remaining M MN M Days Set 4 Backwash Total p EXIT TO x1000 al lt DISPLAY Ren SCREENS Step 11 To enter Installer Display press the NEXT and A buttons simultaneously for five seconds and release Step 2I Adjust days from 1 28 Press NEXT to go to Step 3I Press REGEN to exit Installer Display Step 3I Use A or V buttons to set time of the regen hour Press NEXT to go to Step 4I Press REGEN to return to previous step Step 4I Use A and Y buttons to set the regen minutes Press NEXT to exit Installer Display Press REGEN to
17. user displays and the volume display in Diagnostics will be shown as 0 e f 7 is selected the regeneration will occur on the selected day s of the week see instructions contained in Installer Display Settings The total flow and flow rate user displays and the volume display in Diagnostics will not be shown even if a meter is used f 7 Volume M is selected the regeneration will occur on the selected day s of the week see instructions contained in Installer Display Settings If a meter is not used the total flow and flow rate user displays and the volume display in Diagnostics will be shown as 0 Press NEXT to go to Step 4CS Press REGEN to return to previous step Step 4CS Press the A or Y buttons to select to regenerate immediately on 0 or at delayed time Immediately on O can only be selected if Volume M was selected in step 3CS and a meter must be installed Delay is the only option for the other Step 3CS selections Press NEXT to go to Step 5CS Press REGEN to return to previous step When using the WS2 control valve the circuit board software must have meter selection choices of 50 and 50L The WS2 valve must be set for the 50 meter selection during programming If the software version does not have both the 50 and 50L selections consult your equipment supplier for a replacement circuit board When using the WS2L valve with older version software that does not have both 50 and 50L selection choices the valve must be set to

Download Pdf Manuals

image

Related Search

Related Contents

Pulsar Evolution - Electrocomponents  Écrire son journal  CUISEUR A RIZ - Delta Import  USBcollabo-20V 取扱説明書 トラブル解決ガイド  micro - Fichier PDF  Snorkel FRENCH Spec Sheets  Tripp Lite 3-Phase User's Manual  手ぶら拡声器2(ポータブル拡声器 NZ  Tecumseh AKA4460YXAXA Drawing Data  Français Instructions de montage : Tiger 800 et Tiger 800XC  