Home

Owner`s Manual - Powerhouse Generators

image

Contents

1. iiu EEE 9 Oe Oe OIG REOK Ge ee 10 Sol GMeCK he engine ONMTOW Sk sate r ggggxmxxmmrrbrrrrr 10 3 2 Check WS TSN OW Cassa te emcee KK KK 11 3 3 Check the air cleaner ccccccccccccccceeesseeeeeeeeeeeaeessseeeeeeeseeaeeesseceeesessseaesseeeeeeesssaaaaeeeeeeeeessaaas 12 4 OPERATINGINSTRUGCTION Sarnen 13 ea Wes eaae ERE aLe g E E EE ll A A A 13 2 2 RlQN allilUAEOPEFAl ON 2222 anne 14 4 3 Operating at extreme temperatures E LL kk kk k k KK KK KK KK YA 14 4A Generale Usern yeke kelk ee kek keke elek eke kb ey eko Vek eer 15 ASAGO AppIIEallONnem ee bik le sh n b n l k n e n ke k nk e Re kk el b s ehe hekan 17 2 20 OUIDULATO Oeno ad LONS dasste ea soei esia a 18 AT TIGA ONC QUO DY yy ky Aka ee Eee ee 19 AO LOW oil alarm Syste EEEREN TARA SANA SANA nA wan az nA an kana ka 45 20 AO ECONOMY SWIC merce EEE 21 l kere selle nn lae la r aO 21 5 MAINTENANGE 2 22 2 2u2 22 22222 22 eur 22 5 1 EmIsslon cOnlrolsysienasases ncn i ki HJ HH n HKH K HK Ki ke aN Rae 22 SAMa ln Sn n eo ye Cle CNIS TP n D ee Eee 24 59 Sono nace sanenantsesasaesaaasneceesassaesaaaesecaseascaesaaaesacatesoeceeoaeenscateso cee oaeenaeanecoeee 25 DAP CLOGS SEIN CE ae 26 5 5 Spark pug mantenan E anne 27 5 6 Spark arrestor maintenance L Lid kk kk KK kek kK KAKA KA K KK KK KK A A KK KK KA 29 6 TRANSPORTING and STORAGE less nial ab babe abe la S n n b 0 406005544044855 48554555455055d5dad
2. amed CLEAN Nala IS CERTIFED TO BE EASSIONG COMPLIANT FOR THE FOLLOWING UBE MCDERATE 25 HOURS F3 INTERMEDIATE 250 HOURS E EXTENDED BOO HOURS BE Cle TO OSIY F MAL FO GASTRO ATR RAD ACTS 23 2000Wi OM 5 2 Maintenance Schedule Air cleaner Maintenance Procedure Spark Plug Clean Adjust Check Adjust Fuel tank amp Clean strainer NOTE 2 Service more frequently when used in dusty areas Regular Service period 1 Perform at every indicated month or operating hour interval whichever occurs first 1st Month Every 3 Months Every 6 Months 1x per Year or or or Or 4 to 6 Hours 50 Hours 100 Hours 300 Hours Every 2 years Replace as necessary 3 Log hours of operation to determine proper maintenance 3 These items should be serviced by an authorized dealer unless the owner has the proper tools and is mechanically proficient See the Service Manual Normal 100 hr 77 F 25 C 24 2000Wi OM 5 3 Changing oil Drain the oil while the engine is still warm to assure rapid and complete draining y Wez Uyife Make sure to turn the engine switch OFF before draining the oil Loosen the cover screws and remove the side maintenance cover Remove the oil dipstick Install the oil drain pipe included with the generator Drain the dirty oil into a container Be sure to allow time for the oil to drain completely Refill with the recommended oil and check to be sure the oi
3. d k 30 8 1 Ti 3f SDONITO ine generalo ss aan 30 6 2 Short term storage of the Generator yaaa kaka kla aaay lalek ke ask ake kak 30 6 3 Storing the generator for an extended period ELu kk K k kk 31 62 Exercising the Generalo Hl 1y545445y4444 551255145515445251 A 50 ka kAkA A ARA AA TA La ARA AA LATA ARARAT AA 31 ZAIROVUBEESEOOTNG ke 2222er ea eee 32 KENONG WILNOL Al MM N N acetate ect ee ee ee 32 7 2 Appliance does not OPCLAatel ccssecccccccssssececcceeeeecececeeusecececeeuseeeeeseeaueeeeessuauaeeeesssageeeeessaas 33 7 3 NO OULDUT al the DE r ceptacle une 33 9 SREGIEISATIONS ua a 34 9 WARRANTY AND CONSUMER INFORMATION 04024200000000nnnnnnn kk kk kk kK KAK KK KK 35 TOAPENDIX B EMISSION CONTROC SYS TEM essen 37 11 APENDIX C SAFETY AND CHARGING INSTRUCTIONS J S 38 4 2000Wi OM 1 SAFETY INSTRUCTIONS M This generator is designed to give safe and dependable service if operated according to instructions Read and understand the Owner s Manual before operating the generator Failure to do so could result in personal injury or equipment damage Exhaust gas contains poisonous carbon monoxide Never run the generator in an enclosed area Be sure to provide adequate ventilation The muffler becomes very hot during operation and remains hot for several minutes after stopping the engine Be careful not to touch the muffler while it is hot Let the engine cool before stor
4. in good order and that its electrical rating does not exceed that of the generator M When an electric motor is started the overload indicator light Red may go on momentarily while the output indicator light Green remains on This is not a problem as long as the overload light only flickers on briefly Overload Light Red 120 V 20A Duplex Receptacle NEUTRAL FLOAT IAG NEUTRE FLOTTANT r TZON AG s E0Hz iPhass Circuit Breaker Le EHG ME EGOMOMT SWITCH SWITCH OH OFF OW OFF O D d OFF BERL FLOA INS ETA FLOTTANT 18 2000Wi OM 4 7 DC application PN 7 CAUTION The DC receptacle may be used for charging 12 volt lead acid batteries only Other types of batteries may burst causing personal injury or damage To prevent the possibility of creating a spark near the battery connect the charging cable first to the battery then to the generator Disconnect the cable first at the generator Before connecting charging cables to a battery that is installed in a vehicle disconnect the vehicle s ground battery cable Reconnect the vehicle s ground battery cable after the charging cables are removed This procedure will prevent the possibility of a short circuit and sparks if you make accidental contact between a battery terminal and the vehicle s frame or body Do not attempt to start an automobile engine with the generator still connected
5. 1 5000 RPM with economy switch off Electronic A7RTC Recoil Automotive unleaded gasoline SAE 15W 40 OW 40 for extreme cold weather 15 6 oz 460 ml 1 4 gal 5 3 L 3 0 7 5 hours 56 66 dB 0 024 0 028 in 0 6 0 7 mm 0 0039 0 0008 in 0 10 0 02mm 0 0059 0 0008 in 0 15 0 02mm Dimensions Overall dimension LxWxH in mm 2114 X 1114 X 19 in 540 x 285 x 485 mm Dry weight 62 Ibs 28kg 34 2000Wi OM g WARRANTY AND CONSUMER INFORMATION POWERHOUSE GENERATOR WARRANTY Generators are covered by this warranty from the date of original retail purchase for a period of 1 year for residential use and 6 months for commercial applications Units used in rental fleets reconditioned or as demonstration models will be considered commercial usage The warranty coverage is continual from the original date of purchase and does not restart upon the replacement of any part or complete unit Individual parts replaced at any point during the warranty period are only eligible for warranty coverage for the balance of the original warranty period Eligibility To be eligible for warranty replacement the product must be purchased in the United States or Canada from an authorized Coast Distribution dealer This warranty applies to the original retail purchaser only and is not transferable Proof of purchase and the serial number is required Coverage Pre approved parts and labor costs will be covered by POWERHOUSE f
6. FLOATING a NEUTRE FLOTTANT l j Can SEM 120 A kan SEM Hz 1Phase Circuit Breaker EWG IME SWITCH SWITCH D 12V B JA on OFF ON OFF TI ij BEL ECONOMY Battery Charge Circuit Breaker 4 8 Low oil alarm system The low oil alarm system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase falls below a safe limit the low oil alarm system will automatically shut down the engine the engine switch will remain in the ON position If the low oil alarm system shuts down the engine the low oil alarm indicator light Red will come on when you pull the starter rope and the engine will not run lf this occurs add enough of the approved engine oil to raise the level to the top line on the dipstick 120V AC 20A NEUTRAL FLOATING TATRA NEUTRE FLOTTANT l j Can SEM 120W A kan EM Hz IPhass Circuit Breaker ENG IME ECONOMY SWITCH SWITCH OFF OH OFF OW O Low Oil Alarm Light Red 20 2000Wi OM 4 9 Economy switch Economy switch ON This position is recommended to minimize fuel consumption and noise while in operation Engine speed is kept at idle automatically when the electrical load is disconnected and returns to the proper speed to match the power of the electrical load when the load is reconnected NOTE E Ihe economy system does not operate effectively if the
7. label is found in two locations Please record this information below and keep this manual in a safe place along with the bill of sale Engine Serial Number Bar Gode Number Date of Purchase Name of Selling Dealership Please go to www powerhouse products com register and register your unit today Online registration will be accepted as proof of purchase Online registration will make sure you are protected in the event you have lost your receipt and will significantly speed the process in the event warranty service is necessary For warranty assistance Phone 877 544 4449 Fax 800 263 0280 E mail warranty powerhouse products com 9 2000Wi OM 3 PRE OPERATION CHECK A WARNING m Be sure to check the generator on a level surface with the engine stopped 3 1 Check the engine oil level A CAUTION Do not use non detergent oil or 2 stroke engine oil It will void the warranty and will shorten the engine s service life Use a high detergent premium quality 4 stroke engine oil certified to meet or exceed U S automobile manufacturer s requirements for API Service Classification SG SF u Change the oil in a new engine between the first 4 to 6 hours of operation to clean manufacturing debris and contamination Use SAE 15W 40 viscosity oil unless operating at ambient temperatures below 32 F 0 C For temperatures below 32 F use SAE OW 40 viscosity oil See page 14 for more inf
8. plug carefully by hand to avoid cross threading After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wrench to compress its washer If a used plug is being reinstalled it should only require 1 8 to 1 4 turn after being seated 10 Reinstall the spark plug cap on the spark plug securely 11 Reinstall the spark plug maintenance cover Bm The spark plug must be securely tightened An improperly tightened plug can A CAUTION become very hot and possibly damage the generator MH Never use a spark plug with an improper heat range WE Always use an A7RIC resistor type spark plug Using a non resistor spark plug will interfere with AC output 28 2000Wi OM 5 6 Spark arrestor maintenance WE ifthe generator has been running the muffler will be very hot Allow it to cool Ay CAUTION j N before proceeding WE The spark arrestor must be serviced every 100 hours to maintain its A NOTE efficiency Remove the six M6 screws and remove the muffler grill Remove the two M4 screws holding the spark arrester to the muffler Use a stiff wire brush to remove carbon deposits from the spark arrester screen Inspect the screen for holes and replace it if necessary m oY A M4 Screws i rf iy INN j wu i yr n J p Her t 1 1 i 1 J Vi li b11 di li ORL w u Se 1 an Hus d m ne Spark Arrestor M6 Screws 29 2000Wi O
9. smoking materials sparks and any other source of combustion away from the generator during refueling M Do not overfill the fuel tank there should be no fuel above the top of the fuel strainer After refueling make sure the tank cap is closed properly and securely M Be careful not to spill fuel when refueling Spilled fuel or fuel vapor may ignite If any fuel is spilled make sure the area is dry before starting the engine M Avoid repeated or prolonged contact with skin or breathing of vapor KEEP OUT OF REACH OF CHILDREN Fuel tank capacity 1 4 gal 5 3 Liters Fuel Level N Fuel Strainer Do not use a blend that contains more than 10 ethanol Do not use gasoline containing methanol An octane rating of 87 or higher is recommended NOTE Fuel system damage or engine performance problems resulting from the use A O of fuels that contain an improper alcohol blend are not covered under warranty Gasoline containing alternate fuels m Before buying fuel from an unfamiliar station determine if the fuel contains ethanol and if it does confirm the type and percentage of ethanol used If you notice any undesirable operating symptoms while using a gasoline that contains ethanol or one that you think contains ethanol replace it with a gasoline that you know has the proper blend 11 2000Wi OM 3 3 Check the air cleaner Loosen the maintenance cover screws and remove the maintenance cover Remove three air filter re
10. without a load However repeatedly stopping the generator without disconnecting all loads can cause damage to the generator or appliances Shutdown 1 2 3 Turn off all connected appliances and disconnect from the generator Push the engine switch on the control panel to the OFF position Turn the fuel valve off 2 2000Wi OM PREFACE Thank you for purchasing a POWERHOUSE generator This manual covers operation and maintenance of POWERHOUSE generator model 2000Wi All information in this publication is based on the latest product information available at the time of printing We reserve the right to make changes at any time without notice and without incurring any obligation No part of this publication may be reproduced without written permission This manual should be considered a permanent part of the generator and should remain with it if it is resold Pay special attention to statements preceded by the following words e Indicates a strong possibility of severe personal injury or death if 4A WARNING instructions are not followed e Indicates a possibility of personal injury or equipment damage if A CAUTION instructions are not followed A NOTE e Gives helpful information lf you have a problem with this generator do not return it to the store where you purchased it For warranty support call 877 544 4449 from 8am to 6pm ET email us at warranty powerhouse products com or send a fax to 800 263 0280 e Fail
11. 2000Wi Digital Inverter Generator By POWERHOUSE 2000Wi OWNER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE USING 2000Wi OM Quick Start Guide A WARNING e Use outdoors only Generators produce carbon monoxide a poisonous colorless odorless gas that can cause death or serious injury e Always operate on a level surface e Keep away from rain snow or other wet conditions e Keep away from smoking materials sparks and other sources of combustion when refueling Pre Operation 1 Add oil by removing the maintenance panel and inspecting the dipstick Fill the oil reservoir with 15 6 oz 460 ml of oil or to the full mark on the dipstick Use appropriate grade high detergent premium quality 4 stroke engine oil Use SAE 15W 40 viscosity oil unless operating at ambient temperatures below 32 F 0 C For temperatures below 32 F use SAE OW 40 viscosity oil See page 14 for more information about operating at extreme temperatures Carefully add regular unleaded automotive gasoline up to the shoulder of the fuel strainer To avoid spilling fuel use care to not fill too quickly or over fill Avoid getting dirt dust or water in the fuel tank Do not use a blend that contains more than 10 ethanol Do not use gasoline containing methanol An octane rating of 87 or higher is recommended Operation 1 2 10 Ensure that no loads have been connected to the AC receptacles Open the fu
12. 3 2000Wi OM 4 2 High altitude operation At higher altitudes the standard carburetor air fuel mixture will be excessively rich Performance will decrease and fuel consumption will increase High altitude performance can be improved by installing a smaller diameter main fuel jet in the carburetor If you always operate the generator at altitudes higher than 5000 feet 1500 m above sea level have your authorized dealer install a high altitude main jet Even with suitable carburetor jetting engine horsepower will decrease approximately 3 5 for each 1000 feet 305 m increase in altitude The affect of altitude on the horsepower will be greater than this if no carburetor modification is made yv CAUTION Be sure to have any carburetor modification reversed before operating at lower altitudes Operation of the generator at an altitude lower than the carburetor is jetted for may result in reduced performance overheating and serious engine damage caused by an excessively lean air fuel mixture 4 3 Operating at extreme temperatures High temperature adversely affects generator operation Generator performance will decrease 1 for each 10 F 5 5 C increase in temperature above 85 F 29 C The normal operating range of this generator is 0 to 113 F 18 to 45 C Although the generator can operate at 0 F 18 C it will be necessary to use a lower viscosity engine oil such as SAE OW 40 Even with OW 40 oil the engine will be more d
13. M 6 TRANSPORTING and STORAGE 6 1 Transporting the generator When transporting the generator it should always be secured upright in its normal operating position with the fuel valve and engine switch turned OFF When transporting the generator A WARNING E Do not overfill the tank m Do not operate the generator while it is on or in a vehicle E if you must transport the generator in an enclosed vehicle drain all fuel from the generator 6 2 Short term storage of the Generator During short term storage the generator should be secured upright in its normal operating position with the fuel valve and engine switch turned OFF Avoid placing the generator in direct sunlight when storing lf the generator is left in an enclosed area or vehicle high temperatures inside could cause residual fuel to vaporize resulting in possible explosion 30 2000Wi OM 6 3 Storing the generator for an extended period 1 Be sure the storage area is free of excessive humidity and dust 2 Regardless of whether you plan to store your generator with or without fuel add an appropriate amount per the instructions on the bottle of fuel stabilizer and run the generator for 5 minutes This will assure that any fuel trapped in the system will have the stabilizer in it If you do not drain the fuel it is best to keep the tank full as it will be less likely to form condensation in the fuel tank You may also opt to add the fuel stabili
14. POSITIVE POST IS GROUNDED TO THE CHASSIS SEE ITEM vi v FORANEGATIVE GROUNDED VEHICLE CONNECT THE POSITIVE RED CLIP FROM BATTERY CHARGER TO POSITIVE POS P UNGROUNDED POST OF BATTERY 38 2000Wi OM vi vii viii n St CONNECT THE NEGATIVE BLACK CLIP TO VEHICLE CHASSIS OR ENGINE BLOCK AWAY FROM BATTERY DO NOT CONNECT CLIP TO CARBURETOR FUEL LINES OR SHEET METAL BODY PARTS CONNECT TO A HEAVY GAUGE METAL PART OF THE FRAME OR ENGINE BLOCK FOR A POSITIVE GROUNDED VEHICLE CONNECT THE NEGATIVE BLACK CLIP FROM BATTERY CHARGER TO NEGATIVE NEG N UNGROUNDED POST OF BATTERY CONNECT THE POSITIVE RED CLIP TO VEHICLE CHASSIS OR ENGINE BLOCK AWAY FROM BATTERY DO NOT CONNECT CLIP TO CARBURETOR FUEL LINES OR SHEET METAL BODY PARTS CONNECT TO A HEAVY GAUGE METAL PART OF THE FRAME OR ENGINE BLOCK CONNECT CHARGER AC SUPPLY CORD TO ELECTRIC OUTLET AND WHEN DISCONNECTING CHARGER TURN SWITCHES TO OFF DISCONNECT AC CORD REMOVE CLIP FROM VEHICLE CHASSIS AND THEN REMOVE CLIP FROM BATTERY TERMINAL FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE A SPARK NEAR THE BATTERY MAY CAUSE A BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY vi vii CHECK POLARITY OF BATTERY POSTS A POSITIVE POS P BATTERY POST USUALLY HAS A LARGER DIAMETER THAN A NEGATIVE NEG N POST i ATTACH AT LEAST A 60 CM 6 GAUGE AWG INSULATED BATTERY CABLE TO A NEGATIVE NEG N BATTERY POST CONNECT
15. RANTY STATEMENT Your Warranity Rights and Obligations The California Air Resources Board and The Coast Distribution System Inc POWERHOUSE are pleased to explain the emissions control system warranty on your 2008 and later small off road engine SORE In California new SOREs must be designed built and equipped to meet the State s stringent anti smog standards The Coast Distribution System Inc POWERHOUSE must warrant the emissions control system on your SOREs for the periods of time listed below provided there has been no abuse neglect or improper maintenance of your SOREs Your emission control system may include parts such as the carburetor fuel tanks fuel caps fuel lines the ignition system and catalytic converter Also included may be hoses belts clamps connectors and other emission related assemblies Where a warrantable condition exists The Coast Distribution System Inc will repair your small off road engine at no cost to you including diagnosis parts and labor Manufacturer s Warranty Coverage The emissions control system is warranted for two years If any emissions related part on your engine is defective the part will be repaired or replaced by The Coast Distribution System Inc Owner s Warranty Responsibilities e As the SORE owner you are responsible for the performance of the required maintenance listed in your Owner s Manual The Coast Distribution System Inc recommends that you retain all receipts
16. TAGE SELECTOR SWITCH REFER TO THE CAR OWNER S MANUAL IN ORDER TO DETERMINE THE VOLTAGE OF THE BATTERY AND TO MAKE SURE THE OUTPUT VOLTAGE IS SET AT THE CORRECT VOLTAGE IF AN OUTPUT VOLTAGE SELECTOR SWITCH IS NOT PROVIDED DO NOT USE THE BATTERY CHARGER UNLESS THE BATTERY VOLTAGE MATCHES THE OUTPUT VOLTAGE RATING OF THE CHARGER j NEVER PLACE THE CHARGER DIRECTLY ABOVE OR BELOW THE BATTERY BEING CHARGED GASES OR FLUIDS FROM THE BATTERY WILL CORRODE AND DAMAGE THE CHARGER LOCATE THE CHARGER AS FAR AWAY FROM THE BATTERY AS DC CABLES PERMIT k DO NOT OPERATE CHARGER IN A CLOSED IN AREA OR RESTRICT VENTILATION IN ANY WAY CONNECT AND DISCONNECT DC OUTPUT CLIPS ONLY AFTER SETTING ANY CHARGER SWITCHES TO THE OFF POSITION AND REMOVING AC CORD FROM THE ELECTRIC OUTLET NEVER ALLOW CLIPS TO TOUCH EACH OTHER m FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUSE A BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY i POSITION AC AND DC CORDS TO REDUCE RISK OF DAMAGE BY HOOD DOOR OR MOVING ENGINE PARTS li STAY CLEAR OF FAN BLADES BELTS PULLEYS AND OTHER PARTS THAT CAN CAUSE INJURY TO PERSONS iii CHECK POLARITY OF BATTERY POSTS A POSITIVE POS P BATTERY POST USUALLY HAS A LARGER DIAMETER THAN A NEGATIVE NEG N POST iv DETERMINE WHICH POST OF BATTERY IS GROUNDED CONNECTED TO THE CHASSIS IF NEGATIVE POST IS GROUNDED TO CHASSIS AS IN MOST VEHICLES SEE ITEM v IF
17. THE POSITIVE RED CHARGER CLIP TO THE POSITIVE POS P POST OF BATTERY POSITION YOURSELF AND THE FREE END OF CABLE AS FAR AWAY FROM BATTERY AS POSSIBLE THEN CONNECT THE NEGATIVE BLACK CHARGER CLIP TO FREE END OF CABLE DO NOT FACE BATTERY WHEN MAKING FINAL CONNECTION CONNECT CHARGER AC SUPPLY CORD TO ELECTRICAL OUTLET AND WHEN DISCONNECTING CHARGER ALWAYS DO SO IN REVERSE SEQUENCE OF CONNECTING PROCEDURE AND BREAK FIRST CONNECTION WHILE STANDING AS FAR AWAY FROM BATTERY AS PRACTICAL o USE OF AN ADAPTER IS NOT ALLOWED IN CANADA IF AGROUNDING TYPE RECEPTACLE IS NOT AVAILABLE DO NOT USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN p THE GENERATOR STATOR WINDING IS ISOLATED FROM THE FRAME AND FROM THE AC RECEPTACLE GROUND PIN q ELECTRICAL DEVICES THAT REQUIRE A GROUNDED RECEPTACLE PIN CONNECTION WILL NOT FUNCTION IF THE RECEPTACLE GROUND PIN IS NOT FUNCTIONAL 39 2000Wi OM 2000Wi y Powerhouse Products DTS Manufacturing 7930 S W Burns Way Unit C Wilsonville OR 97070 www powerhouse products com 40 2000Wi OM Revision 2011 09 26
18. be considered Do not exceed the current limit specified for any one receptacle Do not connect the generator to a household circuit This could cause damage to the generator or to electrical appliances in the house Do not modify this generator or use it for purposes other than its intended use Do not connect an extension to the exhaust pipe When an extension cord is required be sure to use a rubber sheathed flexible cord Also make sure to use the proper size and length cord 16 Gauge Cords a 16 gauge cord between 0 and 100 feet long will safely handle tool and appliance loads up to 10 amps 14 Gauge Cords a 14 gauge cord between 0 and 50 feet long will safely handle tool and appliance loads between 10 and 15 amps 12 Gauge Cords a 12 gauge cord between 50 and 100 feet will safely handle tool and appliance loads between 10 and 15 amps Keep the generator away from other electric cables or wires such as commercial power supply lines The DC receptacle can be used while the AC power is in use If you use both at the same time be sure not to exceed the total power for AC and DC Most appliance motors require more than their rated wattage for start up 16 2000Wi OM 4 5 AC application 1 Start the engine and make sure only the output run indicator light Green comes on 2 Confirm that the appliance to be used is switched off before plugging into the control panel 120 V 20A Duplex Receptacle Run Light Gr
19. covering maintenance on your SORE but The Coast Distribution System Inc POWERHOUSE cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance e As the SORE owner you should however be aware that The Coast Distribution System Inc may deny your warranty coverage if your SORE or a part has failed due to abuse neglect improper maintenance or Unapproved modifications e You are responsible for presenting your SORE to distribution center or service center authorized by The Coast Distribution System Inc POWERHOUSE as soon as the problem exists The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days If you have any questions regarding your warranty coverage you should contact the North America service center for POWERHOUSE products Phone 1 877 544 4449 Sam to 6pm ET Fax 1 800 263 0280 E mail warranty powerhouse products com 36 2000Wi OM EMISSION CONTROL SYSTEM WARRANTY Your POWERHOUSE generator engine complies with U S Environmental Protection Agency Environment of Canada and the state of California if the model is certified by CARB The following systems and or parts are covered by this warranty Failures or improper operation of the following systems and components will be diagnosed and repaired with no charge for labor or parts Fuel System Carburetor including the choke system and replaceable high altitude
20. d fuel in the exhaust Contact your authorized POWERHOUSE service center to obtain the correct replacement parts and service on this system 37 2000Wi OM 11 APENDIX C SAFETY AND CHARGING INSTRUCTIONS a SAVE THESE INSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS b WORKING IN THE VICINITY OF ALEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF THE UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ AND FOLLOW THE INSTRUCTIONS PROVIDED EXACTLY c TO REDUCE RISK OF BATTERY EXPLOSION FOLLOW THESE INSTRUCTIONS AND THOSE MARKED ON THE BATTERY d NEVER SMOKE OR ALLOW AN OPEN SPARK OR FLAME IN THE VICINITY OF THE BATTERY OR ENGINE e USE CHARGER FOR CHARGING A LEAD ACID BATTERY ONLY IT IS NOT INTENDED TO SUPPLY POWER TO AN EXTRA LOW VOLTAGE ELECTRICAL SYSTEM OR TO CHARGE DRY CELL BATTERIES CHARGING DRY CELL BATTERIES MAY CAUSE THEM TO BURST AND CAUSE INJURY TO PERSONS AND DAMAGE TO PROPERTY f NEVER CHARGE A FROZEN BATTERY g IF IT IS NECESSARY TO REMOVE BATTERY FROM VEHICLE TO CHARGE IT ALWAYS REMOVE GROUNDED TERMINAL FROM BATTERY FIRST MAKE SURE ALL ACCESSORIES IN THE VEHICLE ARE OFF IN ORDER TO PREVENT AN ARC h STUDY ALL BATTERY MANUFACTURER S SPECIFIC PRECAUTIONS SUCH AS REMOVING OR NOT REMOVING CELL CAPS WHILE CHARGING AND RECOMMENDED RATES OF CHARGE i FORA CHARGER HAVING AN OUTPUT VOL
21. e exercised on a regular basis This will prevent the accumulation of varnish or sludge in the fuel system remove moisture from the generator windings Additionally the engine seals and moving components will be lubricated Exercise the generator by running it with at least a 1 2 load 950W for 15 minutes per month Gasoline fuel treatments to prevent contamination of your fuel supply are available from your dealer Fuel varnishing necessitating replacement of the carburetor is not a warrantable failure 31 2000Wi OM 7 TROUBLESHOOTING 7 1 Engine will not start Is there fuel in the tank Refuel the fuel tank Arels the engine switch and fuel switch Turn the engine switch and fuel switch on Is there enough oil in the engine NO Add the recommended oil YES Is there a spark from the spark plug A WARNING No Replace the Stillno Take the generator to an authorized m Be sure there is no spilled fuel spark plug Spark Powerhouse dealer around the spark plug M Spilled fuel may ignite To check spark 1 Remove the spark plug cap and clean any dirt from around the spark If the engine still does not plug start take it to an authorized 2 Remove the spark plug and install generator dealer the spark plug in the plug cap 3 Attach the plug side electrode to your ground wire 4 Pull the recoil starter sparks should jump across the gap Spark Plug Cap Spark Plug 32 2000Wi OM 7 2 Appl
22. ed Exclusions THIS WARRANTY DOES NOT EXTEND TO PARTS AFFECTED OR DAMAGED BY ACCIDENT AND OR COLLISION NORMAL WEAR FUEL CONTAMINATION OR DEGRADATION USE IN AN APPLICATION FOR WHICH THE PRODUCT WAS NOT DESIGNED OR ANY OTHER MISUSE NEGLECT INCORPORATION OR USE OF UNSUITABLE ATTACHMENTS OR PARTS UNAUTHORIZED ALTERATION OR ANY CAUSES OTHER THAN DEFECTS IN MATERIAL OR WORKMANSHIP OF THE PRODUCT THIS WARRANTY DOES NOT EXTEND TO NORMAL MAINTENANCE ITEMS SUCH AS BELTS HOSES SPARK PLUGS WHEELS AND FILTERS PAST THE FIRST SCHEDULED REPLACEMENT OR SERVICE INTERVAL FOR THESE ITEMS WHICHEVER COMES FIRST Disclaimer of Consequential Damage and Limitation of Implied Warranties THE COAST DISTRIBUTION SYSTEM INC DENIES ANY RESPONSIBILITY FOR LOSS OF TIME OR USE OF THE PRODUCT TRANSPORTATION COMMERCIAL LOSS OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGE ANY IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THIS WRITTEN LIMITED WARRANTY Some states do not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages Therefore the above exclusions and limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Replacement Parts Availability To purchase replacement parts please refer to the www powerhouse products com website 35 2000Wi OM CALIFORNIA EMISSIONS CONTROL WAR
23. een NEUTRAL FLOAT IAG NEUTRE FLOTTANT 6OHz IiPhase EWG HE SWITCH SWITCH bo 12 B JA H OFF OW OFF O s g r 5 QO B SEA FLOTAN M Substantial overloading that continuously lights the overload light Red may CAUTION J damage the generator Marginal overloading that temporarily lights the overload light Red may shorten the service life of the generator Be sure that all appliances are in good working order before connecting them to the generator lf an appliance begins to operate abnormally becomes sluggish or stops suddenly turn off the generator engine switch immediately Disconnect the appliance and examine it for signs of malfunction 17 2000Wi OM 4 6 Qutput and Overload Lights 1 The output indicator light Green will remain illuminated during normal operating conditions 2 If the generator is overloaded in excess of 2 0 kW or if there is a short in the connected appliance the output indicator light Green will go out the overload indicator light Red will turn on and current to the connected appliance will be shut off 3 Remove all electrical loads from the generator and investigate the cause of the overload 4 To reset the overload condition Red light stop and restart the generator The Green indicator light should be illuminated within 10 seconds NOTE WE Before connecting or reconnecting an appliance to the generator check that it is
24. el valve If the fuel tank was empty it may also be necessary to pump the primer bulb 15 to 20 times to get fuel to the carburetor Push the engine switch on the control panel to the ON position Move the choke lever to the START position Pull the starter grip lightly until resistance is felt then pull briskly out Repeat until the engine starts Move the choke lever to the RUN position after the engine warms up The green RUN light will illuminate when the generator is ready for use Before connecting any loads ground the generator with a length of heavy cable connecting the generator s grounding terminal to an external ground source Make sure that all appliances to be connected have been switched off and are in good working order Confirm that the combined electrical rating of the appliances does not exceed that of the generator Connect the appliance to the appropriate receptacle on the generator s control panel To minimize fuel consumption and noise push the economy switch to the ON position This setting regulates the engine s speed so that it matches the needs of the connected loads Do not use the economy setting if you are connecting items with electric motors that have a high amperage draw during startup or with appliances that cycle on and off rapidly In an emergency pushing the Engine Switch on the control panel A NOTE to the OFF position will automatically stop the engine with or
25. electrical appliance requires rapid on off cycling of power E When high electrical loads are connected simultaneously turn the economy switch to the OFF position to reduce voltage fluctuation or shutdown WE In DC operation turn the economy switch to the OFF position Economy switch OFF The economy system does not operate Engine runs at the rated load RPM NEUTRAL FLOATIMG NEUTRE FLOTTANT eee TEN A s B Ha IPhase EHG NE ECONOMY SWITCH SWITCH 12W B JA on OFF ON OFF oc Economy Switch 4 10 Stopping the engine To stop the engine in an emergency 1 Push the engine switch on the control panel to the OFF position NOTE m In an emergency pushing the engine switch on the control panel to the OFF position will automatically stop the engine with or without a load However repeatedly stopping the generator without disconnecting all loads can cause damage to the generator or appliances Normal Shutdown 1 Turn off the connected equipment and disconnect from the generator 2 Push the engine switch to the OFF position 3 Turn the fuel valve to the OFF position NEUTRAL FLOATING NEUTRE FLOTTANT D 120W AG oe B Hz IPhass Engine Switch 21 2000Wi OM 5 MAINTENANGE The purpose of the maintenance and adjustment schedule is to keep the generator in the best possible operating condition Inspect or service as scheduled in the tab
26. iance does not operate NO WEBE Is the circuit breaker and ON Reset the circuit breaker YES Take the generator to an YES authorized Powerhouse service center Is the green output indicator light NO Is the red overload ON indicator light ON Check the electrical appliance or NO Take the generator to an equipment for any defects authorized Powerhouse h m u service center YES M Replace the electrical appliance or equipment HM Take the electrical appliance or equipment to an electrical shop for repair 7 3 No output at the DC receptacle YE Are Is the DC circuit breaker tripped Take the generator to an authorized Powerhouse service center Reset the circuit breaker 33 2000Wi OM 8 SPECIFICATIONS Generator Model Rated frequency Hz Rated voltage V Rated current A Max current A Rated output W Max output W DC Output Phase Engine Model Type Displacement Compression ratio Engine speed Ignition system Spark plug Starting system Fuel Lube oil Oil Capacity Fuel tank capacity Continuous running time at rated output 1 4 load Noise level no load full load dB 23 7m Tune Up Specifications Spark Plug Gap Valve Clearance Intake Valve Clearance Exhaust 2000Wi 120 15 8 16 7 1900 2000 12 V 8 3 A Single XG 152F 4 stroke vertical shaft air cooled OHC gasoline engine 125 cc 9 2
27. ifficult to Start EM Do not operate the generator when the ambient temperature is below O F 7 WARNING 18 C M Do not operate the generator when the ambient temperature exceeds 113 F 45 C Recommended oil SAE 0W 40 ET EEE OF 32 F 113 F 18 C 0 C 45 C 14 2000Wi OM 4 4 Generator use Be sure to ground the generator when loads are connected A WARNING M To prevent electrical shock from faulty appliances the generator should be grounded Connect a length of heavy cable between the generator s ground terminal and an external ground source E Connections for standby power to a building s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes Improper connections can allow electrical current from the generator to back feed into the utility lines Such back feed may electrocute utility company workers or others who contact the lines during a power outage When utility power is restored the generator may explode burn or cause fires in the building s electrical system M Do not connect the generator to an automatic transfer device Severe damage to the inverter module may result WE Do not run the generator in an enclosed area Running the generator in any location that is not well ventilated even for a few minutes can kill you 15 2000Wi OM Ay CAUTION A NoTE The total wattage of all appliances connected must
28. ing the generator indoors To ensure safe operation Gasoline is extremely flammable and explosive under certain conditions Refuel in a well ventilated area with the engine stopped Keep away from cigarette smoke and sparks when refueling the generator Wipe up spilled gasoline at once 2000Wi OM 7 WARNING This generator is not intended nor designed for use as a standby power supply and should never be used as such Severe property damage and or severe personal injury or death may result Never connect this generator to an automatic transfer switch ATS Severe damage to the generator will occur To avoid accidents or equipment damage always make a pre operation inspection before you start the engine Place the generator at least 3 ft 1 m away from buildings or other equipment during operation Operate the generator on a level surface If the generator is tilted fuel spillage may result Know how to stop the generator quickly and understand operation of all controls Never permit anyone to operate the generator without proper instructions Keep children and pets away from the generator when it is in operation Keep away from moving parts while the generator is running Generators are a potential source of electrical shocks when misused do not operate with wet hands Do not operate the generator in rain or snow and do not let it get wet Do not operate this generator inside a compartment Doing
29. l level is at the upper line on the dipstick Reinstall the dipstick and then the maintenance cover and tighten the screws securely oo Se YS Recommended oil A SAE OW 40 BET Sa aa O F 32 F 113 F 18 C 0 C 45 C Recommended oil is SAE 15W 40 when ambient temperature is above 32 F 0 C SAE OW 40 is recommended if operating temperatures are below 32 F 0 C Engine oil capacity 15 6 fl oz 460 ml Oil Drain Pipe l j Ik Dip Stick La h v r M j who SSS SS Ww A Lowest oil N Level Oil Fill Hole mM Please dispose of used motor oil in a manner that is compatible with the A NOTE environment and local disposal regulations Do not throw it in the trash or pour it on the ground 25 2000Wi OM 5 4 Air cleaner service A dirty air cleaner will restrict air flow to the carburetor To prevent carburetor malfunction service the air cleaner regularly Service more frequently when operating the generator in extremely dirty areas A WARNING M Do not use gasoline or low flash point solvents for cleaning They are flammable and explosive under certain conditions MH Never run the generator without the air cleaner otherwise rapid engine wear may A CAUTION result i i i Loosen the panel screws and remove the side maintenance panel gt Remove three air filter retaining screws Remove the air cleaner cover and check the air cleaner element Clean or replace the e
30. lacement parts and accessories have the responsibility to guarantee that their replacement products will not adversely affect emission performance Maintenance Maintain the generator according to the maintenance schedule in this section Service items more frequently when used in dusty areas or under conditions of high load temperature and humidity Air Quality Index only for California certified models CARB requires that an air quality index label be attached to every certified engine showing the engine emission information for the emission duration period The label is provided for the user to compare the emission performance of different engines The lower the air index the better the engine emission performance The description of durability is helpful for the user to learn the engine emission duration period and the service life of emission control system Refer to the warranty section of this Owner s Manual for more information The air quality index label is designed to be permanently affixed to the generator and removal should not be attempted IMPORTANT EMISSIONS INFORMATION YONGKANG XINGGLUIANG ELECTRICAL MANUFACTURE CO LTD THIS ENGINE IS CERTIHED TO OPERATE ON UNLEADED GASOLINE THE ENGINE CONFORMS TO V 5 EPA REGS ESON RES MEETS 2011 GALIFORMA EXH AND EVP EMSS LA FOR SI SORE ENGINE FAMILY BYKXS 1251XG ENGINE DISPLACEMENT 1 506 LUBRICANT REQUIREMENTS SF 13 EXHAUST ECS TWC PAIR EVAP FAMLY ECSCM gag ety toy DATE
31. le below There are no special operating instructions for the break in period for the engine but the oil should be changed between the first 4 to 6 hours of operation to remove any manufacturing debris or contamination A WARNING E Shut off the engine before performing any maintenance If the engine must be run make sure the area is well ventilated The exhaust contains poisonous carbon monoxide gas A CAUTION E Use genuine POWERHOUSE parts or their equivalent The use of replacement parts which are not of equivalent quality may damage the generator E When repairing or replacing components of the emission control system only use parts known to comply with EPA standards 5 1 Emission control system Emission source Exhaust gas contains carbon monoxide nitrogen oxides NOx and hydrocarbons It is very important to control the emissions of NOx and hydrocarbons as they are a major contributor to air pollution Carbon monoxide is a poisonous gas The emission of fuel vapors is a source of pollution as well The POWERHOUSE generator engine utilizes a precise air fuel ratio and emission control system to reduce the emissions of carbon monoxide NOx hydrocarbons and evaporative fuel emissions Regulation Your engine has been designed to meet current Environmental Protection Agency EPA and the California Air Resources Board CARB clean air standards The regulations dictate that the manufacturer provides operation and maintenance
32. lement if necessary Wash the element in a non flammable or high flash point solvent and dry it thoroughly Soak the element in clean engine oil and squeeze out the excess oil Reinstall the air cleaner element and the air cleaner cover Tighten the cover screws securely SS SS Reinstall the maintenance cover and tighten the screws securely Air Cleaner Case Air Cleaner Maintenance Cover Cover Air Cleaner Maintenance Screws Cover Air Cleaner Screws Element N_ Na 26 2000Wi OM 5 5 Spark plug maintenance RECOMMENTED SPARK PLUG A7RTC To ensure proper engine operation the spark plug must be properly gapped and free of deposits 1 Loosen the cover screw and remove the spark plug maintenance cover ga O val P Hio mA i 7V A VN _w aie N Spark Plug Access Cover Z A TT Nina 2 Remove the spark plug cap 3 Clean any dirt from around the spark plug base 4 Use the supplied wrench to remove the spark plug Wrench Spark Plug Cap 27 2000Wi OM 5 Visually inspect the spark plug Discard it if the insulator is cracked or chipped Clean the spark plug with a wire brush if it is to be reused Measure the plug gap with a feeler gauge The gap should be 0 024 0 028in 0 6 0 7mm Correct as necessary by carefully bending the side electrode ___ 0 6 0 7mm A 0 024 0 028in Install the spark
33. main jets Engine speed control system Economy Throttle Intake manifold Engine control module Evaporative Control System Fuel tank Fuel cap Fuel strainer Fuel valve Fuel pump Fuel lines Carbon canister including brackets and connectors Air Induction System e Air filter element e Air filter housing Ignition system Ignition module Ignition coil Ignition winding Spark plug Spark plug cap and wire Exhaust system e Catalyst e Exhaust manifold e Secondary air injection assembly Miscellaneous e Pipes tubes hoses and clamps o rings seals and gaskets associated with the above systems Covered up to the first scheduled replacement only See the maintenance schedule 10 APENDIX B EMISSION CONTROL SYSTEM Your generator has an engine that has been approved by the California Air Resources Board Other than the tune up procedures specified in the maintenance section no additional maintenance is required The emission control system has the following components 1 Fuel System The fuel tank cap indicator and hoses are specially designed and constructed to not allow fuel vapors to permeate and be released to the atmosphere 2 Acarbon activated canister collects gasoline vapors from the fuel tank and returns them to the combustion chamber for burning A catalyst is built into the muffler to further treat the engine exhaust A secondary air injection valve adds combustion air to ignite unburne
34. or any failure that is proven to be a failure in material or workmanship under normal use during the applicable warranty time period This coverage is limited to parts labor and ground shipping of repair parts It is the responsibility of the end user to return the product to the nearest authorized repair center as directed by the warranty administration center If in the event that the generator is deemed to be not repairable or the necessary repair would be economically unfeasible the warranty department will authorize its prepaid return to the nearest Coast Distribution location and Coast will prepay the returned shipping to the dealer repair center or consumer The Coast Distribution System Inc reserves the right to repair or replace any part or unit at its option The Coast Distribution System Inc may request defective parts to be returned Anything replaced under warranty becomes the property of The Coast Distribution system Inc To Obtain Warranty Service Do not return this generator to the store where you purchased it Contact any authorized dealer or contact our national customer service center at Phone 1 877 544 4449 8am to 69m ET Fax 1 800 263 0280 E mail warranty powerhouse products com If contacting us by fax or e mail be sure to include a description of the problem as well as all return contact info such as address phone number fax number e mail etc Engine serial number barcode number and proof of purchase are requir
35. ormation about operating at extreme temperatures 1 Loosen the cover screws and remove the maintenance cover 2 Remove the dipstick wipe it with a clean rag and reinsert it into the filler neck screwing it down completely 3 Remove the dipstick again and check the oil level lf the oil level is at or below the lower level of the dipstick refill with the recommended oil up to the top of the upper level marking Do not overfill 5 Reinsert the dipstick and be sure to screw it down until it is tight m Running the engine with insufficient oil can cause serious engine damage m The Low Oil Alarm System will automatically stop the engine before the oil level falls below a safe limit However to avoid the inconvenience of an unexpected shutdown it is still advisable to visually inspect the oil level regularly Engine oil capacity 15 6 fl oz 0 98 pt 460 ml Oil fill hole Dip stick Upper level Lowest oil level allowed 10 2000Wi OM 3 2 Check the fuel level Use automotive unleaded regular gasoline only If the fuel level is low refill to the top of the fuel strainer Never use an oil gasoline mixture or dirty gasoline Avoid getting dirt dust or water in the fuel tank ON gt After refueling tighten the fuel filler cap securely M Gasoline is extremely flammable and is explosive under certain conditions 7 WARNING li Refuel in a well ventilated area with the engine stopped Keep all
36. so may lead to overheating and consequently fire It may also lead to death by asphyxiation Do not modify the enclosure of this generator 6 2000Wi OM 2 COMPONENT IDENTIFICATION Control Panel hit 1 i Exhaust Grill E af 6 oe a a 8 BF m A Maintenance Panel 2000Wi OM 2 1 Control panel 2000Wi 120 V 20A Duplex Receptacle 120 V 20A Overload Light Circuit Breaker Red 120W A 204 Run Light Red NEUTRAL FLOATING HEUTRE FLOTTANT ee CLO A s 6O0Hz 1Phase Ground Terminal ENG IME SWITCH SWITCH OFF Low Oil Alarm Light Red OH Economy Switch Battery Charge Battery Charge Engine Switch Circuit Breaker Receptacle 2000Wi OM 2 2 Serial number and bar code identification and location The generator bar code number and the engine serial number identify your particular unit and are necessary when ordering parts and accessories These two numbers are used by your dealer and The Coast Distribution System Inc for warranty administration and must be supplied before any work can be done The engine serial number can be found stamped on the engine block above oil dipstick It is visible when the maintenance panel is removed Serial Number 100237341 TOS 6ER R I 2000 Wi j IM 1 On the bottom of the generator 1l 0 1 2 7 amp 6 07 2 On the packing carton The bar code number
37. standards regarding the emission control system Tune up specifications are provided in the Specifications section and a description of the emission control system may be found in the appendix to this manual Adherence to the following instructions will ensure your engine meets the emission control standards Modification Modification of the emission control system may lead to increased emissions Modification is defined as the following e Disassembling or modifying the function or parts of the intake fuel or exhaust system e Modifying or destroying the speed governing function of the generator Engine faults that may affect emission Any of the following faults must be repaired immediately Consult with your authorized POWERHOUSE service center for diagnosis and repair Hard starting or shut down after starting Unstable idle speed Shut down or backfire after applying an electrical load Backfire Black smoke and or excessive fuel consumption 22 2000Wi OM Replacement parts and accessories The parts making up the emission control system supplied with the POWERHOUSE engine have been specifically approved and certified by the regulatory agencies You can trust that replacement parts supplied by POWERHOUSE have been manufactured to the same production standard as the original parts The use of replacement parts or accessories which are not designed by POWERHOUSE may affect the engine emission performance The manufacturers of rep
38. taining screws Remove the cover and check the element Clean or replace the element if necessary Replace the air cleaner element and cover Tighten the screws securely Replace the maintenance cover and tighten the screws securely MH Never run the engine without the air cleaner element in place y CAUTION M Rapid engine wear will result from contaminants such as dust and dirt being drawn through the carburetor into the engine Air Cleaner Case Air Cleaner Maintenance Cover Cover Air Cleaner Maintenance Screws Cover Air Cleaner Screws Element 12 2000Wi OM 4 OPERATING INSTRUCTIONS 4 1 Starting the engine Before starting the engine disconnect any load from the AC receptacles Turn the fuel valve lever to the ON position m lf the fuel tank was empty it may be necessary to pump the primer bulb 15 to 20 times to get fuel to the carburetor Push the engine switch on the control panel to the ON position Move the choke lever to the START position Pull the starter grip lightly until resistance is felt then pull briskly out Jk K eS Move the choke lever to the RUN position after the engine warms up Choke Lever Running AM Engine Switch A CAUTION M Do not allow the starter grip to snap back Return it slowly by hand EM Do not let the starter rope rub against the generator body or the rope will wear out prematurely 1
39. to the battery The generator may be damaged Connect the positive charging cord to the positive battery terminal Do not reverse the charging cables or serious damage to the generator and or battery may occur DC operation is only intended for the purpose of charging batteries It should not be used to power DC equipment 1 For DC operation with the engine running turn the economy switch to the OFF position 2 Connect the charging cables to the battery terminals first 3 Connect the charging cables to the DC receptacle of the generator last 19 2000Wi OM A VENI e m Batteries give off explosive gases keep spark flames and cigarettes away Provide adequate ventilation when charging WE Batteries contain sulfuric acid electrolyte Contact with skin or eyes may cause severe burns Wear protective clothing and a face shield If electrolyte gets on your skin flush with water lf electrolyte gets in your eyes flush with water for at least 15 minutes and call a physician immediately WE Electrolyte is poisonous lf swallowed drink large quantities of water or milk and follow with milk of magnesia or vegetable oil and call a physician immediately Mm KEEP OUT OF REACH OF CHILDREN mM The DC receptacle may be used while the AC power is in use E An overloaded DC circuit will trip the DC circuit breaker If this happens reset the circuit breaker to resume operation 120V AC 20A NEUTRAL
40. ure to properly follow these precautions can result in property Ay WARNING damage serious injury or DEATH e Read all labels and the Owner s Manual before operating this generator e Generators produce carbon monoxide a poisonous colorless odorless gas that can cause death or serious injury e Indoor use of a generator can kill quickly Generators should be used outdoors only e Generators should only be used outdoors away from garages and open windows but protected from rain and snow e Check for spilled fuel or leaks Clean and or repair before use e Always stop engine before refueling Wait 5 minutes before restarting e Keep any source of ignition away from fuel tank at all times e The portable generator is not meant to be used as a permanent back up power system for the home A permanently installed stationary generator is designed to be safely used for this specific purpose A WARNING Our generators are designed to give safe and dependable service if operated according to instructions Read and understand the Owner s Manual before operating the generator Failure to do so could result in personal injury or equipment damage Copyright DIS Manufacturing The Coast Distribution System Inc 2011 3 2000Wi OM CONTENTS ROAFE FY INSTRUCTIONS zes 5 2 GOMPONENT IDENTIFICATION oer AE ERAO HANA NEHAN AN 7 2 12 C0nlrol panel 2000W sara eect 8 2 2 Serial number and bar code identification and location
41. zer and run the unit until it is out of fuel If you opt to drain the fuel then continue on with the instructions below Gasoline is extremely flammable and explosive under certain WARNING conditions u Do not smoke or allow flames or sparks in the area 3 To drain the gasoline from the fuel tank turn the engine switch to the OFF position 4 Attach a hose to the drain fitting on the carburetor and place the other end of the hose into an approved gasoline container 5 Turn the fuel valve to the ON position and loosen the carburetor drain screw and drain the gasoline into the approved gasoline container 6 After the fuel tank has been drained with the drain screw loosened disconnect the spark plug wire and pull the starter grip 3 to 4 times to drain the gasoline from the fuel pump 7 Turn the fuel valve to the OFF position and tighten the drain screw securely 8 Change the engine oil 9 Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder 10 Crank the engine several revolutions to distribute the oil and then reinstall the spark plug 11 Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal corrosion 6 4 Exercising the Generator lt is essential that the generator b