Home

A-B Scan No. Item Specifications 1 Description of Function 1.1 A

image

Contents

1. Pulse Oximeter Item Specifications 2 Oo Description of Function A pulse Oxymeter is a medical device that indirectly measures the amount of oxygen in a patient s blood as opposed 1 1 to measuring oxygen saturation directly through a blood sample and changes in blood volume in the skin producing a photoplethysmography Operational Requirements Suitable for all types of patient range adult paediatric and infant and shall operate on AC mains as well as from internal rechargeable battery ystem Configuration ulse Oxymeter complete unit with all standard accessories echnical Specifications t shall be portable unit Display LCD backlight illuminated 2 4 1 4 2 4 3 Parameters and waveform displayed SpO2 pulse rate system status plethysmogram menus for user settings 4 4 SPO2 range 70 100 4 5 Accuracy of SPO2 3 Pulse rate range must be 30 240 bpm Audio visual alarms High low SpO2 and pulse rate sensor off sensor failure low battery It must be suitable to operate in the presence of potentially flammable anaesthetic gases and it shall not cause fire or explosion during operations RS 232C interface for data communication Shall have integrated printer 412 Inbuilt rechargeable battery and shall have battery back up for at least 4 hours Battery charger along with AC adaptor Jto be provided if integrated charger is not there P Oo N yo j o __5 Accessories spares and
2. 1 Accessories All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 41 4 2 4 3 o to 6 2 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Suitable UPS with maintenance free batteries voltage regulation and spike protection for minimum 30 min back up shall be supplied with the system oN K ON W tandards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND 7 2 CE 93 42 EEC Directives or USFDA or TUV approved product certificate o oo oOo Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medea ican nn ay REST omens 8 User Training S 7 I 2 3 Warranty S Documentation List of important spare parts and accessories with their part numbers and costing Certificate of calibration and inspection from factory 7 7 7 1 Optical Coherence Tomography Item Specifications Optical coherence tomography OCT is an interferometry non invasive optical tomographic imaging technique offering millimetre penetration approximately 2 3 mm
3. aT Warranty Comprehensive warranty for 1 year after acceptance Maintenance Service during Warranty Period 1 0 During warranty period supplier must ensure corrective breakdown maintenance whenever required Documentation User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part number and costing Certificate of calibration and inspection from factory Oxygen Concentrator Item Specifications 1 Description of Function Oxygen concentrator produces oxygen from ambient air Operational Requirements Integrated Oxygen sensing device OSD measures concentration at flow meter entrance System Configuration Oxygen Concentrator set complete with Flow Splitter Technical Specifications I Oxygen Concentrator Output flow max 5 LPM Litre per minute Flow meter range to 5 LPM Output pressure 60 kPa Oxygen concentration 95 3 at 1 3 LPM 92 3 at 4 LPM 90 3 at 5LPM 4 5 Time to reach 95 the specified performance 5 minutes 4 7 All filters replaceable coarse filter washable reusable Continuous monitoring with visual and audible alert on O Low and high output pressure 4 5 Four step filtering coarse pre inlet and bacterial of air intake 4 7 8 Low oxygen concentration Oxygen monitor amber light on the front illuminates when oxygen concentrator is below 85 If c
4. 4 24 14 Activation of HF Functions possible via footswitch or manual control switch 4 24 15 Connecting sockets for unipolar and bipolar application can be selected according to individual requirements 4 24 16 Switchover function enables switching between two modes within a user programme via a footswitch from the 4 24 17 Readily plug amp play most common bipolar amp monopolar diathermy instruments with international 4mm single amp 3pin instruments 5mm amp 8mm single pins e g Bovie connectors banana plugs 4 24 18 Maximum Bipolar saline coagulation at 150 250 watt bipolar saline cut 100 watt bipolar saline c cut at 300 watt 4 24 19 Unipolar maximum at 200 300 watt where standard coagulation at 200 watt forced coagulation at 120 watt l spray coagulation at 120 watt 1 14 J sterile area 20 4 24 20 LF HF leakage current monitor 4 24 21 Neutral Electrode safety system Accessories spares and consumables Video Cart 01 no Portable on 4 antistatic antirust 3600 swivel dual castors 2 with brakes Lt Power box with concealed wiring for providing electrical connections of proper rating to all the units All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally
5. 8 LED display for Heart rate and Oxygen saturation Alarms for high and low for Heart Rate Oxygen saturation and probe failure pe The system must have an internal rechargeable maintenance free battery to ensure continued functioning of the unit for z Heart and Oxygen saturation monitor Fixed built monitors dual wavelength probe for Oxygen saturation with digital 9 at least 3 hours during transport It shall have automatic switch circuit for change over from battery to AC and vice versa One suction apparatus with negative suction pressure of 5 120 mm Hg must be provided Shall provide IV fluid stand to support two infusion bottles One Syringe infusion pump with stand compatible with 10 20 and 50 ml syringes compatible with available brand of 4 12 syringes Range of infusion rate 1to 99 ml hr in steps of 0 1ml Shall have display functions for infusion rates alarms for occlusions end of infusion and it shall have internal rechargeable battery 4 Height less than 607 i Depth lesstham 307 Width 337 36 5 Weight 90 100 kg or less 5 Accessories spares and consumables All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity et
6. 9 Ophthalmoscope No Item Specifications Description of Function Ophthalmoscope is an instrument designed to visualize the interior of the eye with the instrument relatively close to the subject s eye and the observer viewing an upright magnified image All 2 Operational Requirements 2 1 Compact system battery operated ystem Configuration Ophthalmoscope set with all standard accessories 2 3 A Technical Specifications Ophthalmoscope set shall have diagnostic head threaded on a handle Head shall have wheel with lens dioptres 0 to 20 and 0 to 20 apertures small large and semi circle fixation star and green filter No 1 4 hall have halogen bulb 2 5V with bright white light Handle shall have on off switch 5 P 1xspare2 5V halogen bulb S U 1 xset of 2 AA batteries 1 5V LR6 alkaline o H 1xstoragecase o O S Shall works with 2 AA batteries 1 5V LR6 alkaline All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 Operating Environment gt gt O The product offered shall be designed to be stored and to operate normally under Climate Temperature Humidity etc o 7 for Sudan 8 User Training Must provide user training including how to use and maintain the equipment Warranty Comprehensive warranty for 1 year after accept
7. 1 Built in auto Quality control facility o Automatic result processing test ordering and transmission to the LIS HIS system laboratory Information System Hospital Information System 4 12 Automatic data archiving and customizable layout Data backup with read write CD ROM drive __ _ _ 4 13 USB ports for easy connection of e g flash drives keyboards ete o O 2 5 4 4 1 4 2 4 3 44 45 E o All standard accessories consumables and parts required to operate the equipment including all standard tools and Lae cleaning and lubrication materials to be included in the offer 6 Operating Environment E The product offered shall be designed to be stored and to operate normally under Power Supply Climate 5 2 6 1 i Temperature Humidity etc for Sudan 6 2 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length 6 7 UPS of suitable rating shall be supplied for minimum 30 min backup for the entire system Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate E Shall meet IEC 61010 2 081 Safety requirements for electrical equipment for measurement control and laboratory 7 0 1 3Juse Part 2 081 Particular requirements for automatic and semi automatic laboratory equipment for analysis and ot
8. Haemostastasis injection needle 1 pc 5 6 All standard Maintenance tools and cleaning lubrication materials where applicable shall be included One set of the standard maintenance accessories for example cleaning brushes rubber seal cleaning cap cleaning adapter silicone oil EO gas sterilisation venting cap shall be included for each scope Operating Environment Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metres in length UPS of suitable rating with voltage regulation spike protection and maintenance free batteries for 30 minutes backup 7 Standards amp Safety Requirements fee O E PERE p ae ae a as ae 6 6 1 Must submit IS013485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate Shall meet IEC 60601 2 18 Medical Electrical Equipment PART 2 Particular Requirements for the Safety of ENDOSCOPIC Equipment 8 User Training o OSO The Supplier shall conduct user training for this equipment to enable operators to use the equipment properly 8 1 The training shall include the use of all operational functions of the equipment as well as routine checks and maintenance expected by users Warranty Comprehensive warranty for 2 years from acceptance 1 Maintenance Service During Warranty Period During the warranty period supplier must ensure planned pr
9. 0o enlarged view diameter 10mm length 30cm autoclaveable 01 no Telescopes shall have low risk of object bum Shall have colour coded for identification Shall have fibreoptic light transmission incorporated 2 Reusable Hand Instruments Hassan s Trocar 10 5mm 1 No Trocar size 10mm 1 No 4 2 3 Trocar size 5mm 3 Nos 4 2 4 Maryland dissecting forceps 5mm dia jaws with size 5 10mm for unipolar coagulation 2 Nos 3 a an 413 414 42 421 42 2 423 424 4 2 5 Gall bladder fundus holding Allis type grasping forceps 5mm dia jaws with size 5 10mm and with fine teeth 1 No 4 2 6 Gall bladder neck holding Allis type grasping forceps 5mm dia jaws with size 5mm and with fine teeth 1 No D 2 Nj a Metzenbaum scissor for unipolar coagulation size 5mm 1 No Hook scissor for unipolar coagulation size 5mm with L shaped jaw 1 No 42 9 Two ways Suction and Irrigation cannula Size 5mm length 36cm used with suction and irrigation handle and hand a ee with stopcock 2 Nos Fenestrated grasping forceps size ae 1 No OnE Needle aspirator size 5mm 1 No 4 2 13 Needle holder size 5mm 1 No 4 2 1 4 2 1 4 2 1 Reduction Sleeves Extractors From 10 11mm to 5mm metallic 2 Nos Reducers From 10 1 1mm to 5mm 2 Nos 4 2 17 High frequency cord 2 Nos 4 3 Cystoscope Telescope 2 nos 30 degree Telescope of size 4mm length 30cm 3cm cle Clip Applicator Medium Large 10mm 1 No Must have v
10. 3 9 1 0 10 1 11 Electric Drill Item Specifications Description of Function Drilling machines are used in a number of orthopaedics surgical procedures for example in making holes in bones for bone screws and in drilling out the medulla or marrow areas of bones Operational Requirements 2 1 Electric driven autoclaveable versatile forward amp reverse mode with oscillating saw hand pieces System Configuration __4 Technical Specifications Z gt 3 4 3 Hand Piece for Drill Cannulated autoclaveable pistol type Oooo o O Speed 1200 to 1500 RPM o O a P Quick coupling chuck Synthesis type er fs a Jacob chuck Forward amp reverse options and Piece for Reamers O Cannulated autoclaveable pistol type __ Speed 400 RPM non damaging to the bone endosteal blood supply Hudson s chuck O Chuck for cannulated reamers Forward amp reverse options 4 5 Sagittal Saw Chuck for K wire O Autoclaveable pistol type O Easy Attachments of blades without Instrument ACL Blades for commonly used sizes Accessories spares and consumables All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 Operating Environment The product offered shall be designed to be sto
11. 6 Operating Environment gt S O The product offered shall be designed to be stored and to operate normally under Power Supply Climate E Temperature Humidity etc for Sudan 5 5 1 1 3 6 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length 6 Suitable UPS with maintenance free batteries voltage regulation and spike protection for minimum 30 min back up shall be supplied with the system Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA approved product certificate Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment 8 Must provide user training including how to use and maintain the equipment A 2 3 p HWA 11 2 Service Technical Maintenance manual in English S O Phaco Machine Description of Function Phaco multification systems are used to break up and remove cataracts lenses of the eye Operational Requirements o 1 l The units must possess irrigation irrigation aspiration ultrasound diathermy and vitrectomy operational modes 3 l Item Specifications ystem Configuration 3is Phaco multification machine complete unit with all standard accessories Technical Specifications 4 1 Phaco multification unit must work on venturi amp peristaltic pump and sha
12. AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA approved product certificate The product shall comply to IEC 60601 2 37 ed1 Medical Electrical Equipment Part 2 37 Particular Requirements for the Safety of Ultrasonic Medical Diagnostic and Monitoring Equipment Type of protection against electric shocks Class I Degree of protection against electric shocks for ultrasound probes Type BEF For ECG electrodes Type CF User Training Must provide user training including how to use and maintain the equipment Warranty Comprehensive warranty for 2 years Maintenance Service during Warranty Period During the warranty period supplier must ensure planned preventive maintenance PPM along with corrective breakdown maintenance whenever required Documentation User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing Certificate of calibration and inspection from factory oa be wl O 1 ae faa a 11 11 11 11 N EEG Machine Item Specifications Description of Function An electroencephalograph uses electrodes placed on a patient s scalp to measure amplify display in graphic form and record the weak electrical signals generated by the brain Electroencephalography is useful in observing and 1 1 diagnosing a variety of neurologic conditions including epil
13. After Image Illumination by 12v Lamp 6 Auto Flashing Fal Auto flashing of slide illumination either simultaneously or alternatively in rapid and variable models P Five Modes of slide illumination namely Normal Flashing Right Flashing R L amp Flashing can be selected 8 Haidinger Brush S SOS One Haidinger brush attachment along with rheostat for speed control and switch for direction reversal Longitudinal 40 55em o O Lateral 30 40em o SOS Vertical 30 50em o O Weight 10 15k o OSOS 220 Volt AC JA set of slides containing 9 pairs o OSO One powercord o SOS One dust Cover S O O Spare 6v Bulbs 2 Nos amp 12v Bulbs 2 Nos gt SS O Cataract Surgical Set Item Specifications Standard Set CE or USFDA or TUV approved certificate Pan Fundoscopic Lenses No Item Specifications 90 78 and gonio lenses CE or USFDA or TUV approved certificate Slit Lamp No Item Specifications Description of Function The slit lamp is an instrument consisting of a high intensity light source that can be focused to shine as a slit It is used in conjunction with a microscope 2 S H Motorized imported table for slitlamp oo U Applanation tonometer s O Beam splitter o 5 Slit lamp camera 5 Accessories spares and consumables All standard accessories consumables and parts required to operate the equipment including all standard tools and clea
14. Facility for self test function Shall have facility to elevate base to offer adjustable range Facility with both servo control as well as air temperature control and servo humidifier Shall have Oxygen port with tubing Continuous bed tilt up to 8 on either sides Head end raise facility with auto lock P Both visual and audible alarms for 18 cases 4 9 4 High low temperature O Air circulation probe system power failure O Humidity control Head end raise facility with auto lock 9 Facility to take x ray and weight without removing baby Facility to display and trending of temperature information on compatible monitors with other physiological parameters Height 140 5 cm depth at least 60 mm width at least 90 mm Mattress to hood distance approx 40 cm Working level approx 90 to 100 cm 4 14 Iris port for tubing leads probes 4 15 Gel mattress approx 4 cm thick and easily washable 4 16 With at least 4 dia castors wheel with swivel in all directions and with front lockable wheels Two shelves cabinets with door 4 17 Weight approx 90 100 kg 4 18 Patient control Servo mode 35 oC to 37 oC and Air control manual mode 20 oC to 37 oC 4 19 Air velocity less than 10 cm sec with inner wall 4 4 2 4 2 4 23 4 24 4 25 C02 flushing according to IEC 60601 2 19 105 1 Maximum C02 concentration inside incubator 0 2 4 26 4 2 All standard acces
15. Temperature Humidity etc for Sudan be 5 o ame o EEE l Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metres in length A N Comprehensive warranty for 2 years 1 10 Maintenance Service During Warranty Period 10 1 During the warranty period supplier must ensure planned preventive maintenance PPM along with corrective breakdown maintenance whenever required 1 11 Documentation gt S O ECG Machine Item Specifications Description of Function ECG Machine is primary equipment to record ECG Signal in various configurations Operational Requirements 2 1 Microprocessor controlled digital 3 channel ECG machine suitable for adult paediatric and neonate applications 3 1 3 channel ECG machine with complete accessories Technical Specifications 3 channel ECG machine with simultaneous acquisition of 12 standard leads aVR aVL aVF I II IHI and V1 6 pre cordials Internal memory for storage of up to 50 ECGs Splash resistant alphanumeric keyboard with function keys With zeroing reset auto base line correction 0 5Hz and 1mV test calibration signal Filter setting for line frequency 50 or 60Hz and tremor Continuous check on the quality of electrodes connection audio visual alert on loss of signal S 4 1 4 2 4 ple e oo oa in ia ie 4 11 Measurements QRS
16. Z o o O 5 1 Shall supply all accessories including o O 4 4 4 Viol aIo a Sale P 2 3 Straight hand piece 120mm 01 no so ly si Fixed Duraguard paediatrics 01 no __ Craniotome cutter bits paediatrics 20 nos o __ Craniotome cutter bits adult 20nos o O Perforator driver 01 no O Cranial perforator 9X12mm Hudson type 02 nos P Cranial perforator 6 9mm Hudson type 02 nos Hudson chuck 01 no Rosen burr for medium hand piece 10 nos Diamond burr for medium hand piece 10 nos Diamond burr for large hand piece 5 nos o i __ Barrel burr for medium hand piece 10 nos o S o ss i Twist drill for small hand piece 10 nos Micro Sagittal Saw Attachment at Micro sagittal saw pencil shape 01 no Barrel burr for large hand piece 05 nos Saw blade for micro sagittal saw 9 13 0 3 0 3mm 04 nos Pin Point burr for medium hand piece 25 nos torage amp Maintenance Oil spray for high speed motor and hand pieces 50 nos Acorn burr for small hand piece 10 nos Oil spray for perforator 05 nos _ Autoclaveable perforated basket with covering lid with holders for motors all other accessories All standard accessories consumables and parts required to operate the equipment including all standard
17. aa 3 faa No 1 1 5 2 1 System complete with all accessories and hand piece is required 3 Technical Specifications 3 1 1 Extracorporeal Lithotripter a Master control unit includes i Holder for the stone catcher 1 ii Electric foot pedal 1 iii Instruction manual 1 tw hel ae iv Spare tube for the pneumatic hand piece without connector 1 stone catcher set with sterile suction tube length vi Carton packages PO b Ultrasound hand piece set includes oo O i Ultrasound hand piece Silicone seals 1 o O iii Wrench 5mm1 o O O iv Transportation case 1 S O e Pneumatic hand piece set includes li Pneumatic hand piece 1 o O ii Adjustment interface 1 iii Probe cap 1 iv Compressed air tubing for hand piece 1 v Silicone probe guide set packing unit 12 silicones 1 iv Probe 1mm length 569mm for combination with 1 Ultrasound probes 3 3mm and 3 8mm 1 2 b vi Transportation case 1 3 2 3 3 3 Compressed air tubing 2 Gel pad 2 7 Compressor 1 a 8 bar 220V a Vacuum body with tub valve silicone tube 15cm with connector 1 b Suction set for Vacuum silicone tubing with 2 connecting pieces 1 SEN T P 9 Vacuum Suction tube a Suction tube for Vacuum 1 6mm 1 Ib Probe 0 8mm length 668mm 1 c Suction tube for Vacuum 4mm 1 d Suction tube for Vacuum 3 5mm 1 a e Probe 1 6mm length 453mm 1 5 3 4 3 All standard accessories consumables parts required for t
18. an optimal frame rate Modes 4D M Mode Steerable PW CW Doppler Colour Doppler and High Definition colour flow with capability of automatically picking up colour flow as a function of focal depth Monitor must be 15 or more high resolution colour monitor __ Tilt and Swivel monitor must be able to view in all angles and all light conditions Colour Flow Imaging for O Increased lateral amp spatial resolution Detection of even subtle areas of turbulence displaying a more physiological blood flow appearance without loss of frame rate Colour flow with capability of automatically picking up colour flow as a function of focal depth 4 16 Application software for Adult Paediatric Foetal and Peripheral Vascular and Trans oesophageal applications All Japplication packages must be built into the system Cine loop memory more than 120MB of memory Tissue Colorization B colour for improved contrast resolution 17 ua oop with memory for pre and post image comparison of any procedure JF Memory 256 frames or more in quad loop M Mode amp Doppler Scroll Memory 40 seconds ormo E Frame grabber facility for postanalyss S S High Frame rate review for better clarity of playback images study in slow motion Minimum 4 8 GB optical disc drive for image storage and retrieval standard with system Dedicated integrated dynamic stress echo package for flexible user d
19. boiler Material of construction O S O 4 2 Material of construction Insulation cover SS sheets Operating temperature 121 OC 138 OC pressure 1 1 to 2 2 kg cm2 of steam pressure Capacity 80 litres Digital microprocessor based PID temperature controller with stored memory Separate cycle timer and easy to read display pressure gauges 7 8 9 1 Indicating lights display all functions including heating low water timer operation temperature set point and actual temperature pring loaded safety valves and automatic vacuum breaker for jacket 49 Removable plug screen for chamber drain c Aii afety lock for door pressure lock safety device Soni SS baffle for even steam distribution in the chamber S Must include chart recorder for temperature and pressure increased power rating for rapid heating applications Electrical heating element to have over temperature protection cut out and maximum electrical power must not to exceed 4 5 KW Accessories spares and consumables Accessories 3 dressing drums seamless stainless steel construction suitable to fit into the autoclave A minimum of two spare lid gaskets All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 Operating Environment 4 4 4 4 4 11 4 12 Ea
20. in length 6 3 Resettable overcurrent breaker shall be fitted for protection 7 Standards and Safety Requirements The unit offered shall be certified to meeting the relevant quality and safety requirements of TUV CE mark MDD USFDA IEC Radiation safety safety of pressurised equipment and any other relevant quality and safety standards 2 7 2 Manufacturer must have ISO certification for quality standards 7 3 Certified to be compliant with IEC 60601 2 38 Medical Electrical Equipment part 2 38 Particular requirements for safety of Electrically Operated Hospital Beds On site operational training till the familiarity of the system and satisfaction of end user shall be provided 1 10 ee ai aes baa ar a a 6l 6 3 eae 8l 9 m User Operating manual in English 11 2 Service Technical Maintenance manual in English 3 11 3 12 3 List of important spare parts and accessories with their part numbers and costing 12 4 Certificate of calibration and inspection from factory Log book with instruction for daily weekly monthly and quarterly maintenance checklist ICU Ventilator ICU ventilator provides artificial respiratory support to the critical patients in the intensive care units Microprocessor Controlled ventilator with integrated facility for ventilation monitoring suitable for new born to adult ventilation __4 Technical Specifications Z gt S 3 Waves Pressure a
21. lower limit 40 140 minute 9 Memory 400 measurement capacity l Printer facility with oscillometric graph of BP and pulse level Supplied with various sizes of cuffs from neonate to paediatric ranges e g 2 5cm 3 0 cm 4 0 cm 5 0 cm 9 cm 12 cm and 14 cm 4 12 4 13 4 14 4 15 aS facility for air leak application error dead battery motion over pressure patient alarm time out and weak signal 4 16 Display Colour LCD display Accessories spares and consumables 5 1 Shall supply adult paediatric and infant sizes of BP cuffs two of each size All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 Operating Environment The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 2 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metres in length Standards and Safety Requirements Must submit IS013485 2003 AC 2007 for Medical Devices AND 6 6 7 7 2 CE 93 42 EEC Directives or USFDA Or TUV approved product certificate 7 Medical Equipment User Training Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of 7 3 0 Must provide user training including how to use and maintai
22. mist to the airways It is commonly fused in treating cystic fibrosis asthma and other respiratory diseases Z 1 Heavy duty compact Nebuliseris required OOOO S Nebuliser complete unit with all standard accessories OOOO 3 Technical Specifications 1 Compact lightweight low noise Durable long life compressor Suitable for heavy duty institutional hospital use must be able to run uninterruptedly for one hour oe Ge Air delivery rate app 15 L min Accessories spares and consumables All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment 8 1 Must provide user training including how to use and maintain the equipment 4 4 4 4 4 4 4 2 3 4 5 P Ollolai P S A ON nN NO 7 7 1 7 io JN
23. screen 3 Syringe loading sensor with KVO keep vein open elf calibrated self diagnosis capability 5 Volume range from 1 999 ml hr or better in 1 ml increment 7 1 Audio visual indicators Multi types A V alarms to include occlusion door open low battery empty etc Open system using standard IV lines 10 Air in line fluid detector Built in rechargeable battery at least two hours operation Clamp pole Input power supply 220 20 V AC 50Hz ae 8 S 6 High accuracy rate lt 2 ae 8l L222 I V Stand Item Specifications This IV saline stand is used for hanging various intravenous items such as blood bag glucose bottle etc 3 1 Adjustable V saline stand with five legs with 4 hooks and five swivels castors Technical Specifications The IV stand shall be made of tubular anti corrosive and antirust treated epoxy powder coated mild steel with a 5 4 1 pronged base fitted on mobile on swivelling castors of approx diameter 50mm The castors must be non rusting and non marking The stand should come with stainless steel double IV hook height adjustable from approximately 1620mm to Zz 2340mm with a screw knob for height adjustment Laryngoscope Set Item Specifications Description of Function 2 o 1 1 2 Operational Requirements 2 1 Battery powered laryngoscope unit handle to take C size batteries System Configuration Si 2 3 4 5 1 4 Laryngoscopy to facilitate trache
24. table must confirm to Watson Jones type design o lt 2 Dimensions OOOO Approx 10 762mm height 1829mm length 762mm breadth with leg size 76x76 mm amp cross bar 76x25mm a3Macna Midse OOOO 4 4 The table shall have epoxy powder coated washable paint finish 4 5 The table must be provided with all necessary attachments O O S Accessories spares and consumabes C O O SOSS All standard accessories consumables parts required for the proper operation of the above item shall be included in the Joffer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Standards and Safety Requirements 7 1 Must submit ISO 9001 or ISO13485 2003 AC 2007 for Medical Devices AND N AIA U NO Gl dh 45 S l 8 1 Comprehensive warranty for 1 year Maintenance Service During Warranty Period 7 2 CE or USFDA approved product certificate 8 Standard warranty conditions are applicable Installation and Commissioning The supplier must accomplish proper commissioning of the item onsite User and or service manual shall be supplied in English General orthopedic set Item Specifications Standard Set CE or USFDA or TUV approved certificate Interlocking Set Item Specifications Standard Set CE or USFDA or TUV approved certificate K wire Se
25. to 17 5X or more if stepped the steps to be stated Assistant Binocular Microscope Assistant Microscope to match the focusing of main Microscope ty ed EZ 4 11 Type Coaxial dual lamp by optical light guide Halogen bulbs no of bulbs voltage wattage and secondary power source to be stated by bidder Fan Cooling arrangement shall be available 4 14 U V Filter U V filters switchable facility for occluding pupillary light Construction Mounting amp Adjustments Arms Counter balanced spring type __ Range of vertical adjustment 300 to 550 mm or more SS __ Rotation of arms not less than 300 deg o Bases _ The base must be stable and must not topple when optical units articulated arm is fully extended _ 1 Dimension of base in mm To be stated bythe Bidder o Means of Mobility s 51 To be stated and stability amp safety arrangements described in details by the Bidder Accessories spares and consumables Spare Halogen Bulbs Sterilizeable amp detachable caps for nobs 2 sets Dust cover for covering the microscopes 1 no E All standard accessories consumables and parts required to operate the equipment including all standard tools and 5 2 cleaning and lubrication materials to be included in the offer Bidders must specify the quantity of every item included in their offer including items not specified above
26. under Power Supply Climate 5 2 1 e Temperature Humidity etc for Sudan 6 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Suitable UPS with maintenance free batteries voltage regulation and spike protection for minimum 30 min back up shall be supplied with the system Standards and Safety Requirements Must submit ISO013485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate 73 Shall be certified to be meeting safety standard IEC 60601 2 18 part 2 Particular requirements for the safety of Endoscopic Equipment 8 User Trainings S Must provide user training including how to use and maintain the equipment 6 2 Warranty S O Comprehensive warranty for 2 years after acceptance Maintenance Service During Warranty Period 0 1 I During warranty period supplier must ensure preventive maintenance and corrective breakdown maintenance whenever required User Operating manual in English List of important spare parts and accessories with their part numbers and costing Lithotripsy No Item Specifications Description of Function An extracorporeal lithotripter is a device that is used to fragment urinary i e kidney ureter and bladder and biliary tract stones These devices are placed at the stone location via an endoscope or laparoscope Boperational Requirements SSS
27. used and number of discharge and monitoring hour 4 26 Must have an electrode contact quality indicator to minimize the risk of ineffective defibrillation The unit shall be portable and come with a carrying bag able to keep all required accessories and consumables Please indicate the weight in kilogram KG of the unit included all accessories and carrying case It shall be within bkg __ t Rechargeable battery 1 pieceon thewi O OOO OoOO SS O Thermal paper x 2 rolls sets o O Power cord x1set D3 wire ECG cable x 1 set for ECG monitoring gt Z o gt S U Disposable ECG electrodes 50 pieces E ee error ere creer ern arene errr AN standard accessories consumables and parts required to operate the equipment including all standard tools A ind cleaning and lubrication materials to be included in the offer 1 tbe product offered shall be designed to be stored and to operate normally under Power Supply Climate l Temperatore Humidity etc for Sudan Comprehensive warranty for 2 years Maintenance Service During Warranty Period During the warranty period supplier must ensure planned preventive maintenance PPM along with corrective breakdown maintenance whenever required 1 User Operating manual in English S O Defibrillator for Cardiology Item Specifications Description of Functions 1 1 To be used in emergency amp critical care departments to meets variou
28. without removing the compressor Must have washable air filter ies Spares and consumables 1 Accessories Humidifier Servo controlled with digital monitoring of inspired gas temperature complete with heating wire 01 no Nebulizer compatible with ventilator 01 Medical Air Compressor 01 no a Filter paper for humidifier for 100 uses I O Non corrosive trolley and hinged arm 01no All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer Operating Environment The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA approved product certificate Certified to be compliant with ANS TEC60601 2 12 01 Medical Electrical Equipment Part 2 12 Particular Requirements for the Safety of Lung Ventilators Critical Care Ventilators Must meet IEC 529 Level 3 IP3X spraying water for enclosure protection water ingress Certified to be compliant with ISO 7767 for Oxygen monitorin
29. 0 DPI resolution and A4 size printing facility 01 no Patient cable and connectors with electrodes and papers for at least 1000 EEG exams and all the necessary power 4 cs ae PE _ fees Fafa minis Stare Stor spo aon ns mange ara NeT CDH for viewing several recordings in tiled or cascading windows cables and other interfaces Optional requirements components for video EEG up gradation All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 6 2 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Suitable UPS with maintenance free batteries voltage regulation and spike protection for minimum 30 min back up shall be supplied with the system 7 Standards and Safety Requirements 7 1 Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate Shall be certified to be meeting the safety standards IEC 60601 2 26 PART 2 Particular requirements for safety of EEG Systems User Training 8 1 Must provide user training including how to use and maintain the equipment Warranty 9 1 Comprehensive warr
30. 52 Ip cm Noise reduction scattered light trap for high contrast dynamics CCD camera technology with ABC and AGC control TV Monitor 2 units LCD monitor side by side for live and reference image ep 4 8 4 7 Video printer for B W thermal printing on paper size 20 x 25 cm resolutions about 300 dpi The video printer can be placed on the monitor trolley 4 1 Indicate here other features and software functions included in this offer All standard accessories consumables parts required for the proper operation of the above item shall be included in the offer gi The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 2 Should work on 220 240V 50 Hz AC Single phase fitted with appropriate plugs and sockets 7 Standards and Safety Requirements ia a er o Ee a Oy M The unit offered shall be certified to meeting the relevant requirements of TUV CE mark MDD FDA and or any equivalent quality and safety standards Certificates showing the compliance of this unit offered with any relevant quality and safety standards MUST be submitted with this TSF 8 User Training S O On site operational training till the familiarity of the system and satisfaction of end user shall be provided poss 220 Warranty lt During the warranty period supplier must ensure planned preventive maintenance PPM at
31. A B Scan 1 Description of Function A Scan can be used for biometric calculation and for quantifying the reflectivity of lesions in the eye and orbit B Scan is used for imaging the anatomy a Operational Requirements ystem completes with all hardware and software and report printer and image recorder is required 3 1 i ies S 3 System Configuration S O Technical Specifications S O 41 Shall have A scan mode o O 42 Shall have B scan mode o 43 Shall have dynamic movie archiving s O 44 Shall have Laser amp video CD recording facility S O 45 Shall have auto amp manual measure function s O 46Shall have distance amp area measurement on B scan images S O AT Shall have vector A scan measurement _4 8 Shall have simultaneous B scan with vector A scan S O __4 9 Shalll have A scan dynamic recording with gain adjustments S O Accessories spares and consumables __ A Scan Probe frequency gt 10 MHz 01 mo DB Scan Probe frequency gt 10 MHz 01 no S O cscs Integrated or compatible recorders printers CD recorder printer 52 All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 Operating Environment 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 1 The product offered shall be designed to be stored and to operate normally under Power Supply
32. Climate Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Suitable UPS with maintenance free batteries voltage regulation and spike protection for minimum 30 min back up shall be supplied with the system 6 1 6 Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA approved product certificate 1 0 1 1 1 1 ho Shall meet IEC 60601 2 37 Medical Electrical Equipment PART 2 Particular Requirements for the Safety of Ultrasonic Medical Diagnostic and Monitoring Equipment 8 1 9 Warranty Auto Refractometer Item Specifications Description of Function 1 Auto refractometer is computerized vision testing machines used obtain and objective measure the eye s refractive error This measurement provides the most accurate prescription for corrective lenses 1 Operational Requirements Auto Refractometer with full auto mode 3 4 4 4 Surface refraction power 33 75 D 67 5 D in 0 01 0 12 0 25 D steps 4 4 4 4 O o NIDN na A WO lM Re 4 13 Minimum pupillary diameter 2 3 mm 4 14 Pupillary distance up to 85 mm in mm steps 4 1 La a 4 5 Cornea vertex distance 0 10 12 13 5 15 mm S lJAccessoriess o O All standard acces
33. S OO Insert drill sleeve 2 5mm Double Drill sleeve 2 0mm 1 5mm i __38 Drill and tap sleeve combined 2 5mm 3 5mm oS OO 30 Drill and tap sleeve combined 3 2mm 6 5mm SSCSCSCS CS T _41 Pointed drill guide with 4 5mm tap sleeve amp 3 2 mm drill sleeve S Oo a2 Screw removal fores O OOOO y O 43 Conical extraction reamer for broken IL Nais O O OC O Oo h Screw holding forceps C ashonowm OOS O __46 Conical extraction screws for damaged hexagonal head screws 3 5mm 4 5mm o Z o P Item Specifications 1 Description of Function 1 1 2 3 1 4 1 This equipment is used in orthopaedic fractures for imaging of bone pathology or fractures on display monitor during operation reduction of fractures E Operational Requirements For continuous fluoroscopy image storage and retrieval The system offered shall be a general fluoroscopy radiology system it should be a non digital non DICOM compatible type _4 Technical Specifications SS Microprocessor based high frequency inverter generator O Z oOo O aX RaT OOOO S ingle focal spot shall not be more than 0 6 mm Anode heat storage capacity not less than 300 KHU Inherent filtration should be at least 3 mm Al eq 4 Nominal voltage 110 kV ENS P Orbital movement shall be 125 Rotation about horizontal axis shall be more than 180 Image Intensifier 4 5 At least 23 cm input screen with direct coupling with camera Shall be at least
34. Thermal Printer O1no Technical Specifications 4 1 Latest generation Electronic Phased array colour Doppler system with Minimum 512 Electronic independent channels Multi dimensional Beam former for generating two images simultaneously one at low end of bandwidth and one at 4 3 high end then selectively retrieves and mixes the components together for finely textured 2 D or B mode image with superior contrast resolution Adult Cardiac and Vascular Probes to be supplied which must be latest generation wide band transducers without 4 4 frequency selection for higher sensitivity of response over a broader frequency range of operation All probes to be phased array Probes for paediatric application and Trans oesophageal Echo for future requirement Harmonic Imaging System must have following modes in harmonic with separate setting for Tissue Harmonic s SOS P Contrast Harmonic both triggered and real time S O B Harmonic Angio s SOS E Quantification of harmonics imaging S O Gain control in two dimensions for additional level of flexibility to image quality control 4 8 Real time high frequency 2D for higher resolution and low frequency Doppler for higher sensitivity in all probes Frame rate must be 300 FPS or more Steerable PW CW in all Phased Array probes High definition acoustic zoom for enlarging sections of 2D and colour flow images with more acoustic information for greater clarity and detail while maintaining
35. ack section made up of high pressure laminate Should have X Ray cassette holder underneath the back section amp should allow insertion of X Ray cassette from either side of the bed A 5 Height 450 840mm s Back section 0 50 degrees o Leg Section 0 30 degrees O Should have step less pneumatic adjustment for Trendelenburg 25 approx antitrendelenburg 15 approx hould be equipped with four articulated half length tuck away side rails Should have a manual quick release mechanism for back section adjustment during emergency situation EE ipped with four ari de rai Should be equipped with large castors diameter 150 mm with central braking and steering facility 4 11 4 12 Mattress of the Bed should be made up of high density foam with Anti Microbial agent incorporated into all components that assists in Prohibiting growth of bacteria amp fungi and easy to clean 4 11 attress should be fully Radiolucent for ease in performing portable X Rays 4 12 4 12 Should have bumpers at all four corners and place for fixing accessories 4 13 Dimensions of bed approx SSCS uw Articulated half length tuck away side rails 04 Nos Operating Environment The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 6 2 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre
36. afety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate Shall meet IEC 60601 1 2 2001 General Requirements of Safety for Electromagnetic Compatibility 74 Shall meet the safety requirements as per IEC 60601 2 27 1994 Medical electrical equipment Part 2 Particular requirements for the safety of electrocardiographic monitoring equipment 8 User Training pu The Supplier shall conduct user training for this equipment to enable operators to use the equipment properly The 8 1 9 1 1 10 1 11 11 1 11 2 11 3 11 4 training shall include the use of all operational functions of the equipment as well as routine checks and maintenance expected by users Warranty S O 91 Comprehensive warranty for 2 years Maintenance Service During Warranty Period User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing 114 ertificate of calibration and inspection from factory During the warranty period supplier must ensure planned preventive maintenance PPM along with corrective breakdown maintenance whenever required Documentation SSS 1141 11 2 Service 113 Nebulizer Heavy Duty Item Specifications Description of Function T Nebuliser is a device used to administer medication to people in forms of a liquid
37. air with full motorized recline facilities with full motorized up amp down movement for 300mm One stand and console with illuminated soft light for examination 6 with controls for ophthalmic chair for recline and up amp down movements back and Required Base dimensions and Floor space Base Dimension Floor Space required 10 Height 7 8 feet 11 Length after reclining 9 10 feet 7 forward movement One foot pedal for the up and down movement is also required Width 4 inch Input power supply 220 20 V AC 50Hz 14 Output 3V 6V 12V 6 Ophthalmic Operating Microscope No Item Specifications Description of Function 1 1 Ophthalmic operating microscopes are used to magnify eye anatomy to assist during ophthalmic surgery Operational Requirements A binocular stereoscopic type microscope with built in illumination provided with facility for changing the magnification without disturbing other alignments i e when the magnification is changed the image remains in focus 3 1 Ophthalmic Operating Microscope Floor Mounted complete unit with all standard accessories 1 Binocular optical head with coaxial illumination S o Wide field minimum 10 X to 12 5X individually adjustable Inclined binocular tube 45 deg Inter pupillary distance 55mm to 75mm Objective Lens focal length f minimum 175 25 amp above Must have dioptric adjustment of 5 00 to 5 00 Total Magnification 4
38. al Maintenance manual in English 11 3 Li 11 3 List of important spare parts and accessories with their part numbers and costing 4 Certificate of calibration and inspection from factory Infant Transport Incubator Item Specifications Description of Function Required for transportation of premature babies and neonates and it can be used for long distance transportation It shall be self contained mobile intensive care station including power supply unit and infusion stand __4 Technical Specifications S O 4 42 It shall be mounted on collapsible trolley having lockable rust free casters of the size 4 inches dia or more and with Jfacility to mount two A type Aluminium oxygen cylinders on rack under the Incubator Single walled incubators with at least two large pot holes for access Iris ports for ventilator amp other tubings Bed level 4 3 l at least 80 cm above ground level Two shelves cabinet with door 4 Mattress to hood distance at least 30 cm Air Mode Adjustable set temperatures between 20 oC to 39 oC Display of set temperatures with resolution of 0 1 oC 4 5 Skin mode adjustable set temperatures between 34 oC to 38 oC Display of set temperatures with resolution of 0 1 oC Alarms of high low and probe failure for the set air mode up to 2 5 oC and skin mode of 0 5 oC of temperatures Oxygen monitor in incubator hood with display of 21 to 100 Oxygen alarms for high low and probe failure 4 4 l 1
39. al intubation during general anaesthesia or cardiopulmonary resuscitation or for procedures on the larynx or other parts of the upper tracheobronchial tree 4 Laryngoscope set McIntosh or equivalent Technical Specifications Blades to be made of surgical grade stainless steel 4 Clip on quick release mechanism for blades which also provides electrical contact for blade light Light to be activated when blade is engaged SI Accessoriess o O Spare bulbs 03 nos fd ae iNeonate size0O O fiiAdult small size 3 ii Adult medium size fiv Adultlarge size SS All standard accessories consumables and parts required to operate the equipment including all standard tools and 5 2 cleaning and lubrication materials to be included in the offer Bidders must specify the quantity of every item included in their offer including items not specified above The product offered shall be designed to be stored and to operate normally under Climate Temperature Humidity etc for Sudan ae Blades One each of following sizes Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate Monitor IBP CO Item Specifications Description of Functions A bedside patient monitor to monitor physiological parameters of patients in the critical care units or operating theatres Operational Requirements It s
40. ance 1 7 gt 2 aL 7 l 2 User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing Certificate of calibration and inspection from factory Maintenance Service During Warranty Period Argon Laser 2 3 4 5 Slit lamp power on the cornea 50 1700 Mw 6 Can be connected with a yag laser __3 Internal water cooled system o a pa 5 Yag Laser Nol SSCS ie Specifications SSS cone angle 16 D Motorized Table Can be connected with an argon laser on the same slit lamp Full Range Of Delivery Accessories Focus shift mechanism to shift the beam contenuously variable Octopus Perimeter 6 Colour Pale Green S _8 Interval 0 3 to 4 9 sec in 0 2 sec increment 9 Spatial Angle 70deg Horizontal Input power supply 220 20 V AC 50Hz Fundus Camera Item Specifications Description of Function A fundus camera or retinal camera is a specialized low power microscope with an attached camera designed to 1 1 photograph the interior surface of the eye including the retina optic disc macula and posterior pole i e the fundus A digital camera converts these images into digital images 2 Operational Requirements 2 1 Digital Fundus Camera provides colour and fundus auto fluorescence FAF imaging within a small compact design 3 4 1 4 2 4 3 4 4 4 4
41. and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer Operating Environment OOOO SS The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate 1 2 3 Certified to be compliant with ANS IEC60601 2 12 01 Medical Electrical Equipment Part 2 12 Particular Requirements for the Safety of Lung Ventilators Critical Care Ventilators 4 5 8 1 Must provide user training including how to use and maintain the equipment lt lt Comprehensive warranty for 2 years after acceptance Maintenance Service During Warranty Period 11 2 ervice Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing 1 0 whenever required 1 1 2 l 10 User Operating manual in English 11 Certificate of calibration and inspection from factory Infusion Pump Item Specifications 1 A microprocessor controlled infusion pump unit is needed to include but not limited to the following features 2 Flat hygienic touch
42. and should be of dry box technology such that it takes the room humidity into account while humidifying Tubing connection to be at the top of the humidifier unit 22 Should have sensors both inside and outside the machine to allow it to accurately make changes in humidity and prevent condensation from forming inside the tube 3 23 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Defibrillator Item Specifications Description of Functions To be used in emergency amp critical care departments to meets various resuscitation and monitoring needs Operational Requirements It shall operate on AC power supply and internal battery System Configurations Defibrillator with complete accessories Technical Specifications 1 Defibrillation function It shall be a manual defibrillator for external defibrillation Able to perform synchronized defibrillation and non invasive pacing therapy Defibrillation energy selection External monophasic 50 360J External biphasic 50 200J External Paediatric neonatal 2 20J System shall be user friendly lightweight and easily transportable Waveform shape biphasic The defibrillator paddles shall be easily interchangeable among adult child infant and internal paddles It shall come with at least adult and paediatric paddles 4 11 Can be used for neonatal paediatric and adult defibrillation 4 12 The unit shall be able to perform defi
43. anty for 2 years 10 Maintenance Service during Warranty Period 10 1 During warranty period supplier must ensure preventive maintenance and corrective breakdown maintenance whenever required 1 11 The bidder must arrange for the equipment to be installed and commissioned by certified or qualified personnel any prerequisites for installation to be communicated to the purchaser in advance in detail S 7 12 i 12 12 2 Service Technical Maintenance manual in English S O Glucometer No Item Specifications 1 Hand held type Glucometer Noy a E a a a i 7 With Start up kits Case is included One box of sticks and punctures is included Indication of high and low measurements 10 Operating instructions is included Hot air Oven Item Specifications Description of Function Hot Air Oven is required for heating a sample under controlled conditions Operational Requirements Microprocessor based system with PID temperature controller with integrated auto diagnostic system with fault indicator System Configuration 3 1 Microprocessor based Hot Air Oven Technical Specifications External Stainless Steel Casing w x h x d Approx 600 x 600 x 600 mm insulated stainless steel door with locking and rear zinc plated steel 2 1 on the three sides for three adjustable perforated stainless steel shelves Forced air circulation by quiet air turbine Fan to ensure uniform temperature Fitted with load indica
44. arranty for 2 years Maintenance Service During Warranty Period During warranty period supplier must ensure preventive maintenance amp corrective breakdown maintenance whenever required User Operating manual in English Service Technical Maintenance manual in English O _ 8 81l ae ar wl 11 11 11 List of important spare parts and accessories with their part numbers and costing Certificate of calibration and inspection from factory a 11 Plaster trolley No Item Specifications CE or USFDA or TUV approved certificate Plates Set No Item Specifications Standard Set CE or USFDA or TUV approved certificate Screws set No Item Specifications Standard Set CE or USFDA or TUV approved certificate No Splint CE or USFDA or TUV approved certificate Traction Bed Item Specifications S No Item Specifications CE or USFDA or TUV approved certificate Traction kit Item Specifications 1 2 Standard kit a CE or USFDA or TUV approved certificate Calposcopy Item Specifications CE or USFDA or TUV approved certificate Gastro Duodeno and Colonoscopy Item Specifications Description of Function 1 Combined gastroscopy Gastro Duodeno and Colonoscopy is an examination of oesophagus gullet stomach and the first part of your small bowel called the duodenum The second procedure is called a colonoscopy This is an examination of large bo
45. as which 1 column with normal 4s increments and 1 column with small adjustments 4s The oxygen flow meter shall have adjustment ranges 1 column approximately from 0 to 1 L min and the other column approximately from 1 to 10 L min The Nitrous oxide flow meter shall have adjustment ranges 1 column approximately from 0 to 1 L min and the other column approximately from 1 to 10 L min The air flow meter shall have adjustment ranges 1 column approximately from 0 to 1 L min and the other column approximately from 1 to 10 L min O2 N20 and air pressure gauges 3 1 1 1 i Battery backup for not less than 90 minutes of operation Autoclaveable CO2 absorbent canister with minimum 2 5kg soda lime All circuits shall be detachable washable and Autoclaveable at most with steam of 134 degree C Type of vaporiser shall be concentration calibrated type such as variable bypass or heated blender or equivalent It shall accommodate two vaporizers 4 19 Come with 2 sets of concentration calibrated type vaporizers and two sets of compatible fillers for one for isoflurane and the other for halothane 4 4 4 14 15 16 18 Stainless steel supporting arm with two articulations and rail clamp Vaporizer is to be maintenance free with easy re filling Gas flow control or Oxygen ratio control 25 26 The N20 and O2 flow control shall be interlocked that the proportion of O2 to N2O will never fall below a minimum 4 23 value i e O2 concentrati
46. ast 3 metre in length User Training Must provide user training including how to use and maintain the equipment 9 Warranty Comprehensive warranty for 2 years from acceptance Maintenance Service During Warranty Period 10 During the warranty period supplier must ensure planned preventive maintenance PPM and corrective breakdown maintenance whenever required Documentation 1 User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part number and costing Certificate of calibration and inspection from factory Wheel Chair Item Specifications Description of Function Wheel chair is used in hospitals for means of mobility by disabled persons or persons who have impairments that limit their ability to walk It shall be a foldable BUT shall NOT a collapsible type The mechanism of folding amp unfolding must be easy Large standard adult size hospital wheelchair fixed foldable type Easy maneuverable __4 Technical Specifications Z gt S 4 2 Dimensions approx W 68 cm x D 110 cm x H 94 cm Seat width approx 450mm 18 43 Wheels to have braking locking mechanism and self propelling SS hoops two swivel castors 200mm dia approx in front 4 4 Tyre sizes Rear approx 60cm 24 solid Mag tyres or Bicycle type spoked wheels and Front approx 200mm 8 Mag swivel casters Accessories spares and consumables Z S O 5 Acce
47. ators to use the equipment properly The 8 1 training shall include the use of all operational functions of the equipment as well as routine checks and maintenance expected by users 9 1 Comprehensive warranty for 2 years 10 Maintenance Service During Warranty Period J ie Preventive and corrective maintenance services during warranty period shall be included User Operating manual in English 2 11 Service Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing 1 4 Certificate of calibration and inspection from factory Emergency Trolley Description of Function A trolley for transportation of a patient in the hospital Operational Requirements It shall be constructed fully with anti corrosive and antirust treated epoxy powder coated steel sheet and tube or better __4 Technical Specifications _ gt S Item Specifications ol 43 Dished shaped top push handles to be fitted at both ends The dished shaped top surface shall be smooth and corrosive jand rust resistance Shall be mobile on 4 x 200mm robust swivelling castors with non marking grey tyres and with at least 2 diagonal 4 4 castors shall have locking brake mechanism All four wheels MUST be fully 360 deg swivels Fixed direction wheels are NOT acceptable To be supplied complete with patient transfer board Smooth board in either heavy duty mild steel or Aluminium 4 5 Approx siz
48. be directly controlled by a setting on the front panel 4 2 4 3 4 4 4 5 4 4 7 4 8 4 9 4 1 4 11 Halogen based observation light must be provided for observing the baby t must be mounted on a pole with sturdy base with lockable castors Accessories spares and consumables 5 All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer _6 Operating Environment The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length 7 Standards and Safety Requirements 7 1 Must submit ISO13485 2003 AC 2007 for Medical Devices AND 7 2 CE 93 42 EEC Directives or USFDA or TUV approved product certificate Shall meet IEC 60601 2 21 Medical Electrical Equipment PART 2 Particular Requirements for the Safety of Infant Radiant Warmers 8 1 Must provide user training including how to use and maintain the equipment Comprehensive warranty for 2 years after acceptance S 10 Maintenance Service during Warranty Period SSS o 0 1 During warranty period supplier must ensure corrective breakdown maintenance whenever required T7 1 1 User Operating manual in English 10 i 11 11 2 Service Technic
49. brillation and monitoring by using disposable electrodes 4 13 Shall have an electrode contact quality indicator to minimize the risk of ineffective defibrillation 4 14 Recharge time shall not be held longer than 10 seconds before discharge 4 15 Energy charge amp discharge and other selection control buttons shall be available at the paddle handles 4 16 ECG monitoring function Shall have a 3 leads ECG Lead I II amp II monitoring capability protected from defibrillation by mean of ECG electrodes and through the paddles monitoring With heart rate display and alarms O 2 p Z p em 2 j Ge p Oo al G2 jN A un 4 7 4 10 44 4 5 46 4 7 48 49 Waveform shape biphasic O 4 13 ui 4 17 4 1 Qo 4 19 With Lead fault indicator 4 20 Shall have an integrated thermal printer recorder with paper speed of 25mm sec 4 21 General function gt Shall have LCD that displaying at least dual ECG channel HR battery status shock indicator and various data Bidder to specify size of LCD screen and the no of waveforms which can be displayed f gt Shall have audio and visual alarms Please indicate in the next column type of alarms available Shall have HR limit and shockable rhythms alarms skal have a rechargeable battery when it is fully charged it shall deliver approximately 40 50 discharges or 2 4 25 hours of continuous ECG monitoring Bidder to specify the type of battery
50. c for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in 1 1 7 Standards and Safety Requirements 1 Must submit IS013485 2003 AC 2007 for Medical Devices AND 2 CE 93 42 EEC Directives or USFDA or TUV approved product certificate Shall meet IEC 60601 2 50 Medical Electrical Equipment PART 2 Particular Requirements for the Safety of Baby Incubators Must provide user training including how to use and maintain the equipment Warranty S Comprehensive warranty for 2 years after acceptance 1 5 6 length 7 7 7 3 Maintenance Service during Warranty Period 10 During warranty period supplier must ensure preventive maintenance corrective breakdown maintenance whenever required User Operating manual in English 1 11 2 Service Technical Maintenance manual in English 2 11 3 List of important spare parts and accessories with their part numbers and costing 4 11 4 Certificate of calibration and inspection from factory Adult Ambo Bag No Item Specifications Description of Function An Ambu Bag also known as a Bag Valve Mask or BVM or Ambu bag is a hand held device used to provide ventilation to a patient who is not breathing or who is breathing inadequately 2 It shall be self inflatable and must have pop up valve non return valve attachment for oxygen tube amp oxygen reservoir System Configuration 3 1 Ambu bag comple
51. ce the cover of the machine must be easy to open from the top amp sides The suction machine must be capable of producing minimum vacuum of approx 700 mm Hg and which must be adjustable and monitored by vacuum gauge of suitable range The suction capacity must be 25 litres per minute and can be regulated It must have two bottles of 2L Each made of unbreakable polycarbonate with ABS Lid with float over flow control device The jars must be graduated in cc levels The suction bottles shall be autoclaveable On Off Switch and power indicator must be available Shall provide foot switch Body material Base top amp panel made of rust proof and corrosion resistant moulded ABS 4 Lithium ion inbuilt rechargeable battery with capacity sufficient for operating in battery mode fully charged for minimum of 1 hour Shall provide with cable for powering suction machine from ambulance car cigarette lighter Accessories spares and consumables 5 1 Accessories Spare bottle 01 no O Lids 02 nos Rubber Seals 02 nos Blades 02 nos 4 5 o o o Suction tubing set at least 5 metres 02 nos O Spare fuse 01 set All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer Operating Environment The product offered shall be designed to be stored an
52. consumables O Reusable infant SpO2 sensor 01 no E All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment User Training 9 Warrany Comprehensive warranty for 2 years after acceptance Maintenance Service During Warranty Period 1 During warranty period supplier must ensure preventive maintenance and corrective breakdown maintenance whenever required User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing Certificate of calibration and inspection from factory Must provide user training including how to use and maintain the equipment 5 l 5 2 6 1 6 7 l 2 3 l 0 0 1 Syringe Pump 1 Descrip
53. d to operate normally under Power Supply Climate Temperature Humidity etc for Sudan ower supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length ec P 7 Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment 8 User Training 9 Warranty Blood Gas Analyzer Item Specifications Description of Function 1 1 Blood gas analysers are used to measure blood gases electrolytes pH values and biochemical parameters of the blood 2 Operational Requirements O OOOO S Fully automatic Blood Gas Analyser with electrodes and built in primer Essential Measured parameters pH pCO2 pO2 tHb Barometric Pressure Na K Ca Cl Bl urea and Sr Creatanine amp Blood sugar All these parameters must be measured simultaneously 4 2 4 3 4 4 Fast analysis time less than 60 seo 4 5 Fully automatic liquid calibration of all parameters at user defined intervals without the use of Gas calibrated reagents external gases tanks or regulators 4 7 Continuous reagent level monitoring with graphic display S 8 Data display on well illuminated adequate size LCD colour touch screen display 9 Data print out on built in graphic printer S
54. diameter of instrument channel minimum 3 5mm Working Length 1650 1700mm O Total length 1950 2000mm Must be compatible with the video system specified ideo Duodenoscope Field of vision more than 100 deg Direction of view Sdeg backward oblique i H Depth of view app 5 50mm SS U Distal end outer diameter not exceeding 13mm H Insertion tube outer diameter 11mm _ _ _ o O SSS o U Bending angulation must be at least up 120 deg down 90 deg Right 110 deg Left 90 deg o o Instrumental channel not less than 4 mm Working length not below 1200 mm Total length 1500 mm Compatible with video system specified 4 4 Video processor with light source amp Monitor Digital Single Chip Medical Video Camera colour system PAL NTSC with integrated Image Processing Module The video processor offered shall be compatible with all type of video scopes such as video gastroscope video colonoscope video duodenoscope paediatric scope double channel scopes therapeutic scopes and double balloon enteroscope for small bowel intervention It shall be compatible with all type of flexible endoscopes by using a suitable ully compatible to the colour systems PAL amp NTSC Controls for colour adjustment to enhancement and balance settings F 4 13 Light Source amp Fiberoptic Cables Ligh
55. dity etc for Sudan 2 Power supply 220 240VAC 50Hz fitted with appropriate plug The power cable must be minimum 3 metres long P Power consumption approx 500 W 7 Standards and Safety Requirements 2 1 7 S User Training O OOOO O Waray SSCS User Operating manual in English Service Technical Maintenance manual in English 1 2 List of important spare parts and accessories with their part number and costing Certificate of calibration and inspection from factory Patient Monitor Item Specifications Description of Function 1 NIBP Monitor measures and displays Blood Pressure values with inflation of the cuffs and is non invasive in operation Operational Requirements Compatible for use in new borns to adults 3 4 1 4 2 4 3 Pressure detection Conductor pressure sensor Continuously display of BP systolic diastolic mean and pulse rate at intervals of 2 3 5 10 15 20 30 up to 180 44 minutes 4 5 Shall have facility of self check system self test o 6 Pressure 00 to 300 mm of Hg Accuracy 5 mm with standard deviation not greater than 8mmofHg 7 Pulse range 40 240 minute accuracy 2 8 Patient alarms o Systolic upper limit 60 240 and lower limit 20 160 mm of Hg MAP Mean Arterial Blood Pressure upper limit 60 200 mmHg and lower limit 20 120 mmHg DIA upper limit 50 180 and lower limit 15 120 mm of Hg O P R upper limit 80 220 and
56. e 1500 1 x 500 w mm All edges shall be rounded curved finished Surface to be smooth to permit easy sliding of patient onto trolley Accessories spares and consumables 51 All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 The product offered shall be designed to be stored and to operate normally under the conditions The conditions include Climate Temperature Humidity etc o Mobile operating light 6 Operating Environment N Description of Function L1 Mobile operating light is required for carrying out operations in an emergency environment and the system can be moved from place to place in hospitals Operating Light Mobile with single light head moveable on casters and with all standard accessories AfTechnical Specifications S O 49 The light shall be designed with good counterbalance mechanism in order to ensure stability of light head in all positions Light head shall not be greater than 400mm diameter er Number of bulb 1 main bulb halogen 24V 150W with 1 backup bulb with auto switching or multi bulbs light head not more than 3 bulbs of halogen 12V 50W 4s Light intensity range shall not be less than 80 000 lux at 1 meter distance from light source Bidder shall attached 4 5 2 i certified test certificated showing the compliance of this requirement with TSF Light temperat
57. efined protocols with stacked sub loops facility Jand contrast stress protocol Tissue movement colorization with quantification possibility for IHD CAD patients 4 24 Three transducer ports will be preferred 4 25 Colour Map resolution up to 128 levels Study Manager gt 1 5 GB for on cart digital acquisition review and editing of complete patient studies Facility of Real time perfusion studies System Peripherals shall include i U CD Writer with calculation facility on playback o o 5 P DVD CD Recorder with 100 CDs and 100 DVDs gt gt S o U Colour Print Paper 500 sheets B W Thermal Paper 10 rolls oo U ECG Cable 02nos O U MODise 10pes S l 21 28 5 1 2 5 All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer Operating Environment The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 6 2 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length ON UPS of suitable rating conforming to international standards shall be supplied for minimum 30 min backup for the entire system Standards and Safety Requirements Must submit IS013485 2003
58. epsy related convulsive disorders and brain death It can also be used to evaluate psychiatric disorders and differentiate among various psychiatric and neurologic conditions In addition electroencephalographic studies can assist in localizing tumours or lesions on or near the surface of the brain 2 Operational Requirements EEG System completes with software for acquisition review and the compatible computer with necessary interface and printer is required Must be PC based with minimum following PC specifications Core 2 duo Corei5 2GB DDR RAM 300 GB 4 1 HDD CD DVD RW 21 LCD TFT Display Key Board Mouse and UPS of suitable ratings with minimum 30 min back up Number of EEG Channels must be 32 with colour coding and another eight channels for Polygraph Also any two channels can be configured as Bipolar AC or DC through software Facility for simultaneous sampling of all EEG channels and multiple sampling rates Networking facility 4 2 43 4 4 Input Impedance gt 100 Mohm Facility to combine all users defined settings into templates or protocol for use in different applications _ Facility for individual channel control customization of montages along with reportage capabilities D Must display a graphical view of the current montage during the EEG recording a 4 o o a La 4 2 43l 4 Facility to define new sensors must be possible as standard 1 e assign to amplifier i
59. ery high quality of rod lens system Must have fibre optic light transmission incorporated The telescope must be autoclaveable Cystoscope Sheath 1 no Cystoscope sheath with luer lock connection of two different sizes must be provided 16 Fr 17 Fr 18 5 Fr and 20 Fr sheath one each with slot for instrument The sheath must be marked and graduated 5 Telescope Bridge 1 no Telescope bridge with one instrument channel to fit with the cystoscope Flexible Grasping Forcep 1 no 7 Fr grasping forcep shall be provided 7 Flexible Biopsy Forcep 1 no 7 Fr 2 Urethrotome Sheath Ino 3 Cold Knife 2 nos o 48l 4 9 i 4 4 1 4 4 4 1 1 ls 14 Resectoscope Sheath 1 no 26 Fr continuous irrigation Resectoscope sheath with ceramic beak shall be provided with set of silicon tube Sheath must be provided with deflecting obturator 4 15 Working Element Set 1 no Working element set passive type with standard accessories like Kollins knife HF cord protection tube cutting loop shall be provided 4 16 Cutting loop 24 Fr 12 nos 4 17 Formalin Chamber 1 No Formalin chamber made of Virgin Acrylic 6mm thickness of appropriate size preferably with three trays for sterilizing the laparoscope 4 18 Sterilization Cidex Tray 2 Nos Sterilization Cidex tray with cover for storage of telescopes hand instruments and other accessories of suitable sizes 4 19 Sing
60. eventive maintenance PPM along with corrective breakdown maintenance whenever required Service Technical Maintenance manual in English 13 11 11 11 3 List of important spare parts and accessories with their part numbers and costing 1 Certificate of calibration and inspection from factory B 46 Cystoscopy Item Specifications Description of Function Laparoscope is used for minimally invasive surgery and comprises of telescope and associated instruments and units 1 Cystoscopy cystourethroscopy is a diagnostic procedure that is used to look at the bladder lower urinary tract collect urine samples and examine the prostate gland La Cystoscopy an endoscopic procedure is used by urologists to examine the entire bladder lining and take biopsies of any areas that look questionable Operational Requirements 2 2 Shall supply the set for Laparoscopic surgery which have units groups of items components as Mentioned in the technical specifications Cystoscope urethroscope set of instruments uses a lighted tip for guidance to aid in diagnosing urinary tract disease 2 2 and prostate disease This surgical test also enables biopsies to be taken or small stones to be removed by way of a hollow channel in the cystoscope 3 Laparoscopic Instrument set with Adult Cystoscope and Resectoscope complete system and with all standard accessories Technical Specifications 1 Telescopes Straight forward Telescope
61. g Must provide user training including how to use and maintain the equipment Comprehensive warranty for 2 years Maintenance Service During Warranty Period User Operating manual in English 1 During the warranty period supplier must ensure planned preventive maintenance PPM along with corrective breakdown maintenance whenever required Service Technical Maintenance manual in English 5 2 6 1 6 7 1 2 3 A D wl 0 0 1 1 wl 1 2 List of important spare parts and accessories with their part numbers and costing Certificate of calibration and inspection from factory Over head heater Infant Warmer System Configuration __4 Technical Specifications _ 4 2 fa Power failure o Heater failure Probe failure o U Time out alarm in manual mode o 43l 4 It must have manual setting for high and low alarm setting It must rotate and swivel in different direction so as to allow taking X ray The light must be dazzle free 6 It must have preferably inbuilt rechargeable battery to run equipment in case of power failure for at least 30 min In servo mode the heater output must be controlled to maintain the baby at the required set temperature The desired temperature range from 25 to 40 oC The resolution must be 0 1 oC The height of the warmer must be adjustable for different types of bed 4 8 I n manual mode the heater output must
62. g mode at least 2 modes of demand and fixed rate Pacing rate 50 150 ppm y Q0 Output current 0 140 mA Pulse width gt 20 msec 4 19 4 2 4 21 4 22 4 23 4 24 4 25 4 26 General function 4 28 Shall have LCD that displaying at least dual ECG channel HR battery status shock indicator and various data Bidder to specify size of LCD screen and the no of waveforms which can be displayed 29 Shall have audio and visual alarms Please indicate in the next column type of alarms available Shall have HR limit and shockable rhythms alarms Shall have a rechargeable battery when it is fully charged it shall deliver approximately 40 50 discharges or 2 4 31 hours of continuous ECG monitoring Bidder to specify the type of battery used and number of discharge and monitoring hour Must have an electrode contact quality indicator to minimize the risk of ineffective defibrillation 4 33 The unit shall be portable and come with a carrying bag able to keep all required accessories and consumables Please indicate the weight in kilogram KG of the unit included all accessories and carrying case It shall be within 8kg S llAccessoriess o All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 1 The product offered shall be designed to be stored and to operate normally under Power Supply Climate
63. g sleeve3 5mm tip Large hexagonal screw driver 3 5mm tip exagonal screw driver with fiber handle Box joint type 3 5 mm tip crew driver shaft G C end 2 5mm mall plate bender pair late bending plier roller type late bending press crew driver shaft G C end 3 5mm tip arge plate bender pair late bender for reconstruction plates mall depth gauge arge depth gauge Large neutral and loaded drill guide Counter sink with T handle with 5 0mm head Counter sink with T handle with 8 0mm head Small neutral and loaded drill guide DCP Drill guide for 2 7mm screws Counter sink with T handle 6 mm head Counter sink with G C End 5mm head ounter sink with G C End 6mm head Quick coupler handle T Type Quick coupler adapter for drill bits Tap sleeve 3 5mm Counter sink G C End 8 0mm head uick Coupling handle fiber uick coupling tap handle Long T Type J N nJ AIIN _ as i W Nn Nine N oo N 2 Large neutral and loaded drill guide o Oo 19 Counter sink with T handle with 5 0mm head o Oo Counter sink with T handle with 8 0mm head o i OOo Small neutral and loaded drill guide o OO DCP Drill guide for 2 7mm screws s Oo Counter sink with T handle 6 mm head _ _ S OO Counter sink with G C End 5mm head S Oo NINININININ INIAN AIIN N O i 2 Q 34 35 3 4 3 2 Double dii seev2 20mm OOOO y y 35 Drill and tap sleeve combined 2 5mm 3 5mm_ _
64. gnal 4 21 10 Universal jaw assembly to adapt cable of any make of fibre optic cable without adapter 4 21 11 Light Cable Fibre optic light cable of size 4 8mm or as appropriate with the system in diameter and length 250 300 jcm the same must also be heat resistant 4 21 1 Must be high intensity Xenon light source 4 22 Electronic CO2 Insufflator 1 unit 4 22 1 Microprocessor controlled fully automatic gas fill 4 22 2 LCD based central display monitor with multilingual text amp graphics 4 22 3 Must have an adjustable flow rate of 0 to 30 40 litres per minute and a pressure range adjustable between 0 30 mm Hg 4 22 4 4 22 5 Silicon autoclaveable tubing with luer lock attachment 4 22 6 Soft approach pressure control for safe recovery of abdominal pressure 4 22 7 The insufflations must have an excellent operational safety to the patient and the surgeon and it must be easy to use 4 22 8 Optical and acoustic warning signals for pressure exceeding set limits 4 22 9 Provision for preheating gas to body temperature 4 22 10 The unit shall come with CO2 equipment with mains cord a high pressure hose with an appropriate length universal wrench The unit must be provided with 10 sterile disposable CO2 gas filters 4 22 11 Shall provide one large size cylinders with required regulators and connecting pipe to the insufflator with pressure gauge The suction and irrigation unit shall be a combined unit for performing laparosco
65. hall operate on AC power supply as well as built in battery Monitor Patient Bedside 4 chl colour with ECG Resp SpO2 NIBP Temp 2IBP ETCO2 CO All accessories consumables and etc required for monitoring of physiological parameters specified herein Technical Specifications 3 4 1 High resolution colour flat panel non reflective screen gt 10 display size for at least 4 channel waveforms display Display of up to 4 physiological parameter modules without the need for external devices Display waveform ECG IBP SpO2 CO pulse wave and respiration Numeric data display heart rate pulse rate respiration rate NIBP Systolic Diastolic Mean SpO2 and current time 4d of NIBP measurement With storage of at least 24 hours of trend data in 30 second sampling resolution for all monitored parameters to be displayed graphically and in tabular form Data resolution shall be minimum of 30 second sampling 48 Display of trend 49 a Trend tables in at least with 1 5 15 30 or 60 minute display formats and 4alb Trend graphs in at least 1 2 4 8 12 or 24 hour display formats 4 With storage of events for event recalling review and documentation It shall be able to store and record at least 10 events 4 an The monitor shall be protected against the interference from the electric cautery and other electrical equipment Despite the technical requirements of the networking capability the networking works shal
66. he proper operation of the above item shall be included in the offer 5 5 Environmental factors The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 6 Power Supply Must work on 220 240V 50 Hz AC Single phase fitted with appropriate plugs and sockets The power cable must be minimum 3 metres long Suitable UPS with maintenance free batteries for minimum 30 min back up should be supplied with the system Comprehensive warranty for 2 years Comprehensive training for staff and support services till familiarity with the system 8 1 8 2 8 3 Litholopaxy set Item Specifications Standard Set CE or USFDA or TUV approved certificate Segmodscope Item Specifications N 1 2 4 O 6 CE or USFDA or TUV approved certificate Baby Cot Technical Specifications Mounted on 4 swivel anti static castors of which two with brakes With padded mattress detachable for easy cleaning Mattress cover removable via side zipper Basinet sets and removes smoothly from cart frame Materials High resistance to corrosion tropical environment Frame Epoxy oven baked powder coated tubular steel Mattress High density polyurethane foam with density approx 20 kg m3 Cover Plastic flexible highly tear resistant anti static flame retardant disinfectant and liquid proof washable Dimensio
67. her purposes o 8 User Training Must provide user training including how to use and maintain the equipment a Warranty Comprehensive warranty for 2 years Maintenance Service During Warranty Period During the warranty period supplier must ensure planned preventive maintenance PPM along with corrective breakdown maintenance whenever required Documentation User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing Certificate of calibration and inspection from factory Auto CPAP Item Specifications Should be an auto adjusting CPAP with pressures ranging from 4to 20 cm H2O __6 Should have a backlit LCD display for easy viewing S o ME The unit should have comfort feature A Flex which adjusts air pressure based on patient need on every inhalation amp exhalation Unit should have C flex C Flex mode when unit is running as manual CPAP The unit should have System one resistance control for optimized pressure delivery no matter which mask is used 11 Mask fit and seal monitoring should be capable to check the seal of the mask Should have advanced event detection algorithm which detects and records CA OA CSR RERA Hypopnea Vibratory snore Large leak amp Flow limitation for helping the physicians in opting for alternate therapy 13 l l HUMIDIFIER also should be supplied along with the System
68. ility 4 14 Medical Air Compressor Imported standalone medical air compressor Snap fit with the ventilator module to provide an oil free medical air Air quality must comply with ISO compressed air purity class Peak output flow shall be minimum 160 LPM Replacement of internal filters must be performed without removing the compressor eusable Face Mask amp Nasal Mask Reusable face amp nasal mask with textured dual flap silicone cushion flap for easy fit Medical Air Compressor must automatically activate in the event of wall air supply loss Stability selector for easy fit and angle Ball amp Socket headgear attachments Must have washable air filter Removable forehead support and pad to match the angle of patient s forehead 5 2 Reusable Masks Small Medium and Large 02 set each Connecting hose with regulator flow meter or probe for connection to Pin index oxygen cylinder and BOC type Joxygen wall outlet 3 meter length 01 set 5 4 Humidifier Servo controlled with digital monitoring of inspired gas temperature complete with heating wire 01 no Filter paper for humidifier for 100 uses 5 5 5 6 02cellwith O ring O OOOO SSS 5 7 Silicone test lung adult and child size 01 seteach OOOO S 5 8 Nipple connector 1510mm SSS 5 9 Flow sensors 05 nos SSCS i 05 nos All standard accessories consumables
69. in plastic barrel with cover Operating Environment The product offered shall be designed to be stored and to operate normally under Climate Temperature Humidity etc for Sudan Standards and Safety Requirements 7 1 CE 93 42 EEC Directives or USFDA approved product certificate wl Warranty for 1 year after acceptance o 10 Documentation S OS 10 1User s manual to be supplied in English o O O oo on nN AA o r fete Det O Vital Sign Monitor No Item Specifications 1 Description of Function 1 1 NIBP Vital Sign Monitor is used to continuously monitor the vital parameters including NIBP of critically ill patients 2 Operational Requirements 2 1 Capability of storage of patient data and printing of patient reports Capability to integrate with the HIS and transfer the data through LAN Wireless LAN to any other monitoring room doctor s desk Must be HL 7 compatible for transmitting and receiving data to from LAN HIS 3 System Configuration S O Monitor must have audible and visual alarms capability Alarms must have three distinct audible alarm tones to 4 3 distinguish alarm levels as under Also monitor must permit automatic viewing of alarming parameter waveform and numeric from any bedside in alarm as and when connected in a network 3 Must include hemodynamic calculations and vital sign and graphic trends Trends must be automatically stored for at least 24 hours in at least o
70. in tissue with micrometre scale axial and lateral resolution Operational Requirements OCT machine automatically scans both eyes and produces simultaneously an OCT scan amp red free images System Configuration Optical Coherence Tomography complete unit with all standard accessories Technical Specifications Tomography Imaging Cross sectional imaging of fundus Signal type Optical scattering from tissue Signal source Super luminescent Diode 820 nm Optical power 750 microwatts at cornea Longitude Axial Resolution 20 um in tissue Sample size 2mm heavily calcified tissue Scan patterns Line Circle Concentric Rings Radial lines Scan pixels Adjustable from 1024 axial x 128 transverse to 1024 axial x 768 transverse Scan rate 2 5 msec A scan Longitudinal Depth range 2 mm in tissue fea Pod o H Scanners Galvanometric mirrors O SSS a Powe o Normative database RNFL Retinal Nerve Fibre Layer and Macular thickness Signal type CCD image Field of view 290 x 230 Viewing method Flat panel display O Illumination Near IR Red free Internal fixation 32 x 16 LED Dot Matrix External fixation Slit lamp type adjustable blinking LED undus Alignment Documentation Power consumption 700VA Footprint 120 x 85cm 48inches x 34inches PC wor
71. ith built in charger O 4 35 Monitor shall be operated by the battery for at least 60 minutes Come with Alarms for all monitored parameters including exceeding user selectable upper and lower limits life threatening alarms lead probe sensor disconnection system failure or error Alarm shall have at least 3 levels Crisis Warning and Advisory Alarm notification shall be given by Audible and Visual With networking capability to interface with the central monitor 4A RS232 port with interface with computer System architecture shall be designed such that deactivation or failure of any bedside or central station device on the network shall not disable inhibit or degrade communication functions among any other devices in the system Accessories Spare Parts and Consumables 5 1 4 4 4 EtCO2 preferably microstream but at least must be able to perform mainstream and side stream EtCO2 monitoring 4 4 4 4 28 29 3 32 33 34 35 4 41 All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 Operating Environment 6 1 The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 6 2 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metres in length Standards amp S
72. kstation with Core i5 CPU with laser printer colour 300 GB HDD DVD Read Write Image capture card and me software loaded for digitization of images 2GB RAM and interfaces to RVG and Intraoral digitization ay a a a O Minimum pupil diameter 3 2 mm E 5 Accessories spares and consumables 51 All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer Operating Environment The product offered shall be designed to be stored and to operate normally under Power Supply Climate d Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length shall be supplied with the system 7 7 2 3 7 Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment Must provide user training including how to use and maintain the equipment Suitable UPS with maintenance free batteries voltage regulation and spike protection for minimum 30 min back up T Warranty S Certificate of calibration and inspection from factory Synaptophore 2 3 4 A 5 ae Vertical Hyper 30 degree Hypo 30 degree Torsional Incyclo 20 degree Excyclo 20 degree Slide Illumination i By rheostat controlled 6v Lamp for each slide
73. l not be included in this offer All parameters modules shall work in all monitors within the network and shall be easily interchangeable by the user There shall be no restriction on the combination of them pia cake with 5 system with cable 1 set and complete reusable ECG electrodes for Adult amp paediatric 1 set eac ECG cable and patient cable 5 leads for disposable electrodes 1 set Disposable electrodes for adult child and infant 50 pcs each Shall come with at least a 2 lead channel ST analysis Rie lethal arrhythmia detection at least with detection amp monitoring of asystole ventricular fibrillation and 11 12 15 17 ventricular tachycardia and bradycardia Pulse oximetry SpO2 with adult and child finger transducer 1 each SpO2 reusable sensor for infant pc Non invasive blood pressure NIBP with reusable NIBP Starter Kit NIBP connection hose 1 set 4 2 neonate 4 2 4 2 5 4 28 Skin Temperature probe adult child amp infant I pe each o 4 29 Invasive blood pressure IBP for monitoringof2TBP S o __4 3 Shall come with one complete set of IBP reusable accessories S Come with one complete set of EtCO2 flow sensor and accessories for mainstream and side stream monitoring 1 set EE each In the case of microstream system it shall come with one complete set of EtCO2 flow sensor and accessories for side 433 stream monitoring 1 set 4 34 Come with internal rechargeable Lithium battery complete w
74. le Chip Camera System 1 No S OSO ixels approx 752 H x 582 V 4 19 10 Integrated optical parfocal zoom lens 25 50mm 4 19 11 DV output S VHS and composite video output 4 19 1 control etc 19 10 11 S 2 Shall have accessories output to control external devices like video printer from the buttons camera head 4 19 13 Focus control digital zoom High Resolution Video Monitor 1 No 4 20 2 Compatible with endovision camera of any make 4 20 3 Screen size diagonal 19 20 Ultra high resolution at least 1920x1200 pixels flat screen TFT LCD 4 20 4 Max horizontal screen resolution in lines gt 1000 lines 4 20 5 Monitor menu displays all controls capabilities and operations via curser keys user defined captions easy to use and 4 20 1 Shall have colour system PAL NTSC S highly dependable Must be composite have multiple video input and out puts BNC RGB Y C SDI DVI etc Power supply of 220 240 FAR VAC 50Hz 4 20 7 Must have facilities for recording the data on computer digital video recorders CD 4 20 8 On screen menu for monitor setting compact and light weight drip water protected dust proof all connecting cables to be supplied 4 20 9 Brightness at least 400cd m2 contrast ratio 700 4 4 20 10 Antireflection coated front glass 4 21 9 Light intensity adjustment continuously adjustable from 0 to 100 manually as well as fully automatically by the l cameras video output si
75. least 3 nos in a year along with corrective breakdown maintenance whenever required 0 10 1 11 Pneumatic Drill No Item Specifications 1 Description of Function bodies bio metal bio plastics methacrylate ceramics and the like 2 Operational Requirements The drill system is required to saw cut dissect curette abrade carve and shape the skull bones and the vertebral The drill system must be able to saw cut dissect curette abrade carve and shape the skull bones and the vertebral 2 1 bodies bio metal bio plastics methacrylate ceramics and the like A wide range of attachments and dissecting tips both for routine and microsurgical work required 2 1 Pneumatic Drill Machine for Neurosurgery with complete accessories 1 oe m1 Nh Main motor unit must be detachable from air supply hose Straight and angled attachments of various lengths must be available for Cranial and Spinal surgery Keyless Change of hand piece with mounted tool must be possible Motor must be converted to an angulated position with or without an adaptor S 4 4 2 4 3 4 4 4 5 Must have Saw hand piece reciprocating oscillating and sagittal with saw blades with same system Foot control for variable speed Compatible low noise medical grade air compressor to run the machine optimally at the required psi Irmi S 7 c aes 4 13 Inrigation pump must be available o OSO 5 Accessories spares and consumables Z O
76. length 1 set 5 7 Silicone test lung adult and child size 1 set each 5 8 Silicone rubber anaesthesia face mask adult and paediatric size 1 pc each 5 9 Operating Environment nn an W N ui A Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metres in length Standards amp Safety Requirements This unit shall be certified to meet ISO9001 and ISO14971 and ISO 13485 2003 AC 2007 or Directive 93 42 EEC 7 1 and its subsequent additional Directives amending to it or equivalent Certificates showing the compliance of this unit offered with any relevant quality and safety standards MUST be submitted with this TSF 8 User Training The Supplier shall conduct user training for this equipment to enable operators to use the equipment properly The 8 1 training shall include the use of all operational functions of the equipment as well as routine checks and maintenance expected by users oo Wario s O 11 1 It must be supplied with detailed operating and maintenance manuals and technical information in the English language Autoclave Description of Function S o 1 l 2 1 Suitable for hospital dressings linen surgical instruments glassware culture media and laboratory wares etc 3 1 4 1 2 __3 System Configuration S __4 Technical Specifications gt S _4 1 Single door high pressure steam sterilizer with double triple walled steam jacket and separate
77. lied with the system Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA approved product certificate Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment User Training Comprehensive warranty for 2 years wl 0 10 1 During warranty period supplier must ensure corrective breakdown maintenance whenever required 1 wl 2 10 Maintenance Service During Warranty Period 1 11 Trial Sets 1 Must provide user training including how to use and maintain the equipment Item Specifications The lenses should be20mm in aluminum amount of 38mm diameter anodized red for minus and black for plus The Sphere lenses with handle and cylinder without handle 2 Trial lenses of good quality the case made of melamine polished wood sturdy and attractive finish 3 ped pE Bflenses Spheres O z a Concave and convex 0 12 b 0 25 to 4 0 in 0 25 steps c 4 5 to 6 0 in 0 5 steps Fd 7 0 to 14 0 in 1 0 steps e 16 0 to 20 0 in 2 0 steps f 0 25 to 3 5 in 0 25 steps g 4 0 to 6 0 in 0 5 steps le Prisms 1 2 1 2 3 4 5 6 8 10 12 Accessories Trial frames one adult size and one for child adjustable with slots i Red glass fo ars ii green glass iii Pin hole iv Slit oo v Two blank discs vi two occlude vii cross cylinder 0 25 and 0 5
78. ll provide light weight steel hand piece Ultrasonic mode shall have continuous and pulse mode Shall provide two IA straight hand pieces with 4 piezo electric crystals Machine must have good panel display with digital control good audio memory set up for surgical parameters 4 6 Shall have facilities for Bipolar Coagulation Phacoemulsification Aspiration and Anterior Vitrectomy _ Ultrasonic tip frequency 29 60 KHz a El i 4 4 4 Phaco power in both linear and pulse mode Ultrasound pulse rate 1 14 pulses sec Tubing 06 nos Ls Silicon Sleeves 50 mos i Testchambers 50 nos S U Diathermy cord 01 no O E l Micro flow tip Auto priming auto fluidic and auto tuning Customized Trolley having wheels with brakes 01 no All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 5 me 8 2 1 2 3 2 1 6 2 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Suitable UPS with maintenance free batteries voltage regulation and spike protection for minimum 30 min back up shall be supp
79. mp Time Volume amp Time and Flow amp Time eed __ 1 3 Loops P V F V P F with facility of saving of 3 loops for reference oS Lt ee 4 4 Trending facility for 72 hours with minimum 5 minutes resolution for recent 24 hours e Tidal Volume up to 200ml SSS fe Pressure isp SSCS Status indicator for ventilator mode battery life patient data alarm settings clock etc Graphic display to have automatic scaling facility for waves fd eas ae Pai x o o o E p C o e Tidal volume Inspired amp Expired O Spontaneous Minute Volume FIO2 dynamic Intrinsic PEEP and PEEPi volume Minute volume Inspired and Expired Plateau pressure Resistance amp Compliance Use selector alarms for all measured amp monitored parameters Modes of ventilation Volume controlled Pressure controlled Total frequency Airway Pressure Peak amp Mean APRV or equivalent PRVC or equivalent Shall have apnoea backup ventilation S Facility to calculate lower and upper inflection point ebulizer with capability to deliver particle size of lt 3 micron amp to be used in both Off and On line 4 13 Shall have automatic patient detection fac
80. n the equipment 1 2 Warrany O List of important spare parts and accessories with their part number and costing Certificate of calibration and inspection from factory Portable Ultrasound Machine Operational Requirements SSCS 3 system Configuration OOOO Item Specifications 1 1 2 1 3 System shall come with main unit 1 probe 1 unit of black and white video thermal printer and Ultrasound gel warmer 1 unit Technical Specifications Latest technology and all digital beam former general purpose standalone ultrasound machine with integrated light weight mobile cart 3 Main applications OB GYN abdominal peripheral vessels and small pars 7 Controls for depth gain compensation body markers with transducer position SCS Shall have realtime continuous dynamic focus 9 Shall have facility for image zoom freeze textannolalon SSS 1 The system shall have extensive calculation software package for Ob Gyn and general imaging The system must have provision for measurement and calculation of distance area volume heart rate and circumference on the image 4 1 a 2 3 4 4 4 4 4 4 4 els 1 1 1 1 1 1 1 1 4 4 le i 4 23 System shall be DICOM ready and capable of being interfaced with HIS RIS PACS 4 24 Facilty for fuvar upgradeabilty SSS 4 2 Probe 2 to 5 MHz convex probe for Obs Gyn and abdominal application is to be supplied 4 2 2 __5 Accessories spare
81. ndard accessories consumables parts required for the proper operation of the above item shall be included in the 5 1 offer Bidders shall specify in a separate Excel worksheet the quantity and details of any items included in this offer which have not been specified in this Technical Specifications Forms Come with reusable standard mono polar pencil handle with 2 button switch 1 unit 7 Reusable mono polar cord x set 5 in AN 8 Come with 2 types of reusable standard mono polar electrodes 1 piece type of electrode 9 Come with 1 piece of reusable standard mono polar coagulation forceps Z Z o Z o o 1 Come with 1 piece of reusable standard bipolar forceps with hand switch o o o 1 Reusable bipolar cord x 1 set 2 Reusable connecting cable for patient electrode x 1 set o O 3 Patient return electrode for Adult amp Child 50 pieces each o O Operating Environment 5 5 5 5 5 5 5 1 1 5 1 6 1 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metres in length 7 Standards amp Safety Requirements 7 1 Must submit ISO13485 2003 AC 2007 for Medical Devices AND 7 2 CE 93 42 EEC Directives or USFDA or TUV approved product certificate Shall meet IEC 60601 2 2 Medical Electrical Equipment PART 2 2 Particular Requirements for the Safety of HIGH FREQUENCY SURGICAL EQUIPMENT The Supplier shall conduct user training for this equipment to enable oper
82. ne minute intervals Numeric monitored data shall be viewable and recordable in a patient chart type format in at least 1 5 15 60 minutes intervals Convenient handle for carrying the same Tnbui gt P P Ur pls wll ala Able to fix with bed trolley nbuilt rechargeable battery for minimum 3 hours of operation ir 5 Paediatric Cuff 01 no Adult Probe SPO2 02 nos Paediatric Probe SPO2 02 nos O Skin Temp Probe 02 nos a All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate Shall meet the safety requirements as per IEC 60601 2 27 1994 Medical electrical equipment Part 2 Particular requirements for the safety of electrocardiographic monitoring equipment Shall meet IEC 60601 1 2 2001 General Requirements of Safety for Electromagnetic Compatibility or must comply 2 1 7 1 2 A with 89 366 EEC EMC directive 4 1 0 1 5 6 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at le
83. nger unsecured barrel etc Must have comprehensive alarm package including Occlusion limit exceed alarm Near end of infusion pre alarm amp 4 9lalarm Volume limit pre alarm amp alarm KVO rate flow Low battery pre alarm and alarm AC power failure Drive disengaged and preventive maintenance pan Rechargeable Battery having at least 5 6 hour backup for about Sml hr flow rate with 50ml syringes Larger battery 4 1 maar i life and indication of residual life will be preferred 5 5 Accessories spares and consumables 1 Accessories Mounting device Docking Station for two or four pumps as per requirement so as to enable to power up to 2 4 pumps with one power cord when mounted on IV pole 01 pc All standard accessories consumables and parts required to operate the equipment including all standard tools and 5 2 cleaning and lubrication materials to be included in the offer Bidders must specify the quantity of every item included in their offer including items not specified above The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 6 2 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length 7 Standards and Safety Requirements 7 1 Must submit ISO13485 2003 AC 2007 for Medical Devices AND 7 2 CE 93 42 EEC Directives or USFDA or TUV approved product ce
84. ning and lubrication materials to be included in the offer 6 Operating Environment gt S O The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length shall be supplied with the system 7 Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND 7 CE 93 42 EEC Directives or USFDA or TUV approved product certificate 73 Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment 8 User Training Warranty 1 10 1 During warranty period supplier must ensure corrective breakdown maintenance whenever required Suitable UPS with maintenance free batteries voltage regulation and spike protection for minimum 30 min back up User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing Certificate of calibration and inspection from factory Basic orthopedic set Item Specifications Hexagonal screw Driver with self holding sleeve2 5mm tip Small Hexagonal Screw Driver 2 5mm tip exagonal screw Driver with T handle3 5mm tip Hexagonal screw driver with sleeve 2 5mm tip Hexagonal screw Driver with self holdin
85. nputs define traces in a mintage define calculated channels Average Source Laplacian or define trends Facility to click any point to display corresponding traces amp Slide pointer to change displayed duration of the overview Facility for sortable list of all events placed in the recording both automatically and manually Facility for automatic time counters and event insertion during hyperventilation P Facility to controlled display Sensitivity for User defined value SSS y O __ Facility to choose low amp high cut filters along with facility to enter any user defined value Facility to file zip U Facility of configurable time base ll i Spike amp seizure software Trend analysis software Paging facility as automatic paging Mouse controlled paging and or Keyboard paging 0 Playback of EEG for one or more channels Facility for zoom magnify EEG trace Facility for copy amp paste of EEG or trends to reports and presentations Facility for Automatic generation of reports g Patient Administration Software Network supported patient and test management software archive to CD or DVD powerful search patient folder workspaces 49 Must have an option of upgrading the digital EEG to Video EEG with day night camera using MPEG 2 3rd generation technology 5 Accessories spares and consumables Accessories O Compatible Laser Printer with 60
86. ns Approx 10 Frame 800 x 400 x 900mm 1 x wx h Bassinet 800 x 400 x 300mm 1 x w x h Frame diameter 30mm gt iameter 30mm Mattress 70mm hy S _ Swivel castors diameter 50mm S O ity 30kg 5 Carrying capacity 30kg 5 Accessories spares and consumables All standard accessories consumables parts required for the proper operation of the above item shall be included in the offer 6 Operating Environment 5 6 7 temperature and relative humidity for Sudan gt 1 8 Warranty o __9 Maintenance Service During Warranty Period gt Z gt S o 1 1 User s manual shall be supplied in English Infant Incubator An infant incubator provides a closed controlled environment that warms an infant by circulating heated air over the 1 1 skin The heat is then absorbed into the body by tissue conduction and blood convection Ideally both the skin and E core temperatures must be maintained with only minor variations o a 2 Operational Requirements High quality with humidity and servo controlled double walled with cabinet incubator The quality of the material shall 2 1 La be very high and crystal transparent System Configuration Infant Incubator Servo Control complete unit with all standard accessories Technical Specifications 4 1 Microprocessor controlled easy access control panel with feather touch switches
87. nsumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 Operating Environment The product offered shall be designed to be stored and to operate normally under Climate Temperature Humidity etc for Sudan 7 l 8 User Training o Warranty s User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing 1 Ae 1 1 2 ILI Maintenance Service During Warranty Period Suction Machine wl 3 1 Shall operate on mains AC supply as well as on battery System Configuration The system consists of Suction machine wih2Jan_ S SS S S S S lt lt CSRS U Mains as well as battery operated S O C fE Suwsontins OOOO L bottles 4 4 Rechargeable battery Technical Specifications 1 The machine shall be portable on four wheels and with a handle for transportation 4 42 The vacuum pump must be totally oil free diaphragm type Must have maintenance free pumps of international design Jfor continuous use 43 Motor shall be of Class F insulation to operate in ambient temperature to withstand up to 50 oC with thermal cut Jouts It must run continuously on invertors UPS To facilitate maintenan
88. nute Volume Total Frequency Fio2 Oooo TEEN Les a aw O Auto PEEP E y Oooo fos od a Rapid Shallow Breathing Index Plateau Pressure Inspiratory amp Expiratory Resistance O Static Compliance Imposed Work of Breathing Peak Plateau and mean airway pressure Must have the following Modes of ventilations Volume controlled Pressure controlled Pressure support SIMV Pressure Control and volume control with pressure support CPAP PEEP 0 50 CM H20 Auto mode Auto flow preferable PRVC Biphasic preferable High frequency ventilation 5 Must have the Alarms for all the measured and monitored parameters 7 Sensors must be automatically calibrated every time it is switched on ust have the ability to calculate Intrinsic Peep are e i lene ad i an a Cs ae Fl P Occlusion Pressure foes as ead i Lae Leg el fice a Negative Inspiratory force edical Air Compressor Imported Built in Medical Air compressor Snap fit with the Ventilator module to provide an oil free Medical air Peak output flow must be minimum 160 LPM Air quality must comply with ISO compressed air purity class Medical Air Compressor must automatically activate in the event of wall air supply loss Replacement of internal filters must be performed
89. on shall never be less than 25 to produce a hypoxic breathing mixture It shall automatically cut off the supply of N20 and other gases and activate an alarm if O2 pressure drops below 28 4 24 l 30PSI It shall sounds at maximum volume every 10 seconds Ventilator Microprocessor based electrically powered and electrically controlled ventilator 4 31 Pressure limitation approximately 10 lt 70emH2000 O 4 32 PEEP positive end expiratory pressure approximately0 20emH20 0 4 27 4 28 4 29 4 30 2 2 2 3 3 N P i 4 3 4 3 c High and low airways pressure f Power failure low battery patient disconnection and others 5 Accessories Spare Parts and Consumables o O All standard accessories consumables parts required for the proper operation of the above item shall be included in the offer 5 2 All standard Maintenance tools and cleaning lubrication materials where applicable shall be included 5 3 Silicone breathing circuit for adult and child 2 complete sets each Connecting hose with regulator flow meter or probe for connection to PIN index oxygen cylinder and BOC type Joxygen wall outlet at least 5 meter length 1 set al bl d el fl Connecting hose with regulator flow meter or probe for connection to N20 cylinder or N20 wall outlet at least 5 Imeter length 1 set Connecting hose with regulator flow meter or probe for connection to air cylinder or wall outlet at least 5 meter
90. oncentration remains below 85 for more than 15 minutes an audible alarm sounds O Power failure oo Battery test Temperature operating range 20 to 60 OC 4 1 S Shall have 4 antistatic swivel casters 2 with brakes and with integrated handle allows for easy moving and positioning Flow Splitter for Oxygen Concentrator ive way split of oxygen flow provided by an oxygen concentrator Each flow can be adjusted individually via its flow meter range 0 125 to 2 LPM Litre per minute The output nozzle can either be fit with tubing or left blank Input pressure approx 50 to 350 kPa Flow splitter allows precise distribution of the oxygen output of a concentrator towards 2 3 4 or 5 patients i e ound level produced 40 to 50 dB A neonates and infants Accessories spares and consumables 5 1 Accessories 2 x Adult cannula with 2m tubing 4 x Infant Paediatric cannula with 2m tubing 3 x Connector for above 4 x Humidifiers 4 x tubing adapter kit 4 x New born cannula with 2m tubing o a EE i pf x SO tmbing o o Ba E All standard accessories consumables parts required for the proper operation of the above item shall be included in the offer Operating Environment The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humi
91. pure cutting to blend cutting cutting with haemostasis Come with 3 mono polar coagulation modes soft forced and spray aR him 3 5 4 4 4 Bipolar mode can be activated by either foot pedal and or auto coagulate by using forceps Desiccate mode for low voltage contact coagulation suitable in delicate tissue work Fulgurate mode for efficient non contact coagulation in most applications 7 Spray mode for coagulation large tissue areas with minimum depth of necrosis Come with 3 bipolar modes precise standard and macro or equivalent 4 4 1 4 1 4 1 4 1 Footswitches shall be splash proof and unaffected by common OR fluid spills easy to clean have suitable mechanical protection against accidental pedal depression and Switches shall not be susceptible to sticking in the ON position Unit must have automatic power regulating feature to always keep minimum current to the patient throughout the procedures Shall come with Return Electrode Contact Quality Monitors RECQMs to monitor the quality of electrode skin 4 17 contact to eliminate the risk of patient s burn It shall give audio visual alarm and deactivate output if contact between patient and electrode is loosened or disconnected 4 22 The unit must have RF activation port to tell other equipment like ECG or EEG that RF current is being generated 5 Accessories Spare Parts and Consumables gt _ A 4 1 4 1 4 4 21 e e 2 All sta
92. py surgeries 4 23 7 Shall come with A unbreakable suction and irrigation bottles of capacity minimum1 5 litres with cap 4 24 Electrosurgical Generator Monopolar Bipolar amp in saline mode 4 24 1 High frequency microprocessor microcontroller based digitally controlled device Silicone suction tubings set reusable pressure domes bacterial filter and sterilizeable polycarbonate 4 24 2 Shall have approx 6 5 or more touch screen for convenient use There shall be no extra button for confusing 4 24 3 Shall be suitable for Open Laparoscopic Endoscopic Urology amp Gynaecology procedures 4 24 4 Full range of monopolar amp bipolar modes for general surgery 4 24 5 EFFECTS mode to fine tune energy delivery to make even finer adjustments for precise tissue management 4 24 6 Tissue adaptive power output for controlled precise and fast cutting 4 24 7 Quick memory function to set and recall settings easily 4 24 8 Automatic smoke evacuation function when combine with insufflators providing a HD view of the cavity 4 24 9 Universal connector with instrument recognition URO amp GYN 4 24 10 Saline detection ensuring the right medium is used in resection in saline 4 24 11 Saline modes for improved ignition and vaporization performance 4 24 12 Shall have double pedal foot switch 4 24 13 Automatic activation of coagulation current as soon as coagulation electrode touches tissue with both branches
93. quired to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer Operating Environment 4 2 4 2 Peed o o 6l The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment User Training 6 1 6 7 7 1 1 2 1 3 1 0 10 1 1 1 1 1 2 9 8 1 Must provide user training including how to use and maintain the equipment Certificate of calibration and inspection from factory Operating Table 1 Description of Function Item Specifications Hydraulic operating tables are simple tables for performing surgical procedures and it works without electrical power Operational Requirements OT Table is required for general surgery and shall have X Ray translucent tops 1 System Configuration Operating Table Hydraulic with complete accessories Technical Specifications Four section table top with divided foo
94. r acceptance Maintenance Service during Warranty Period 3 1 4 ll ice duri whenever required Certificate of calibration and inspection from factory Infant Ventilator Item Specifications Description of Function Paediatric Infant Ventilators provide artificial respiration support to infants and neonates in ICU Wards 2 1 3 1 Operational Requirements The Infant Paediatric ventilator must be easy to operate and must incorporate safety alarms and backup ventilation System Configuration 3 1 Ventilator Paediatric amp Infant with Built in Medical Air Compressor and with complete accessories 4 Technical Specifications O Microprocessor Controlled integrated suitable for neonate and child ventilation Must have not less than 10 inch colour TFT screen for monitoring of the ventilation parameters curves and loops i 4 Must have the facilities for following setting for neonate to child Tidal Volume Flow Pattern Inspiration Plateau Pressure ramp SIMV Rate leva ot fot fod ae ae O CPAP PEEP es a f eel feo aaa Pressure Support FiO2 Pause Time Inspiration trigger sensitivity to flow amp pressure Base Flow Sensitivity for cycling to expiration ust have the capability of monitoring of the following parameters Airway Pressure Expired tidal Volume Minute Volume Spontaneous Mi
95. rate PR interval QRS duration QT QTC P QRT T axes RVS ISVI O 4 12 Shall have interpretation and waveform analysis S O 4 13 Shall have maintenance free digital thermal array printer oS O 4 14 Printer shall be able to print ECG report and must have on off selection O Z oO Ooo 4 15 Shall have ECG lead annotation facility o O 4 16 Paper speed user adjustable 25 and 50mm sec S O 417 CMRR shall be gt 100dB S O 4 18 Sensitivity automatic or user selectable 5 10 and 20mm mV S O 4 4 4 N Fe re XO S Rechargeable battery amp charger integrated in the device Battery autonomy approximately 2 hours The unit shall be compact light in weight easy to carry l N 1 1 4 1 4 4 2 5 All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan p nr m N Power supply 220 240V AC 50Hz fitted with appropriate plug type D round 3 pins The power cable must be at least 3 metre in length Standards and Safety Requirements 1 Must submit ISO13485 2003 AC 2007 for Medical Devices AND 2 CE 93 42 EEC Directives or USFDA approved product certificate Electrical safety conforms to s
96. red and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length tandards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND Medical Equipment l Must provide user training including how to use and maintain the equipment YWarrany S 11 2 Dynamic Eondyla Screw DES Set Item Specifications Standard Set CE or USFDA or TUV approved certificate Dynamic Hip Screw DHS Set Item Specifications Rasp for Austin Moore Standard Stem Rasp for Austin Moore Broad Stem fr 8 User Training Rasp For Thompson Standard Stem Murphy Lane Bone Skid Rasp for Austin Moore Narrow Stem 6 Rasp for Austin Moore Extra Long Sem O OC o __8 Moore Hollow Chisel OOOO SSS __9 Moore Hollow Chisel with Fibre Handle Standard S O il 13 Impactor nylon Faced Large Tip Spare Hook For Extractor 17 19 Tapered Reamer For Bipolar Prosthesis 21Bipolar Trial SemSS SSCS 23 Trial CupHolder SSCS 27 Charnley slotted reamer Orthopedic Table A O Specifications SSSSCSCSC S SCSC SCS Fracture table to use in orthopaedic surgical procedures SCSCS Watson Jones type design fracture table O O oC I Fracture Table with all atachmens O Oo o 1 The
97. rth leakage breaker ELB 4 4 15 5 5 1 5 2 The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 62 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length 6 1 6 2 7 Standards and Safety Requirements 7 1 Must submit ISO 9001 or ISO 13485 2003 AC 2007 AND 7 2 CE 93 42 EEC Directives or USFDA or TUV approved product certificate 7 3 Electrical safety conforms to standards for electrical safety IEC 60601 8User Training S O Must provide user training including how to use and maintain the equipment YWarrany S O Comprehensive warranty for two year 0 0 1 1 1 1 2 1 3 1 4 ertificate of calibration and inspection from factory Maintenance Service During Warranty Period During the warranty period supplier must ensure corrective breakdown maintenance whenever required Diathermy i i 5 aL 3 l ia Operational Requirements It shall operate on AC power supply in the operating theatre System Configurations 1 1 A 300W diathermy machine electrosurgical unit Diathermy Machine Electrosurgical 300W with complete accessories Technical Specifications Nominal HF output 300 Watts at 400 Ohm At least 2 modes of operation mono polar cutting and mono polar bipolar coagulation Mono polar cutting modes shall have different level of effects from
98. rtificate 7 3 Certified for meting IEC60601 2 24 Particular requirements for the safety of infusion pumps and controllers 7 4 Must meet IEC 529 Level 3 IP3X spraying water for enclosure protection water ingress o 8 User Training Must provide user training including how to use and maintain the equipment a Warranty Comprehensive warranty for 2 years Maintenance Service During Warranty Period During the warranty period supplier must ensure corrective breakdown maintenance whenever required Documentation 7 1 11 1 User Operating manual in English 1 1 11 2 Service Technical Maintenance manual in English 11 3 List of important spare parts and accessories with their part number and costing Certificate of calibration and inspection from factory A wl 0 wl 1 1 1 1 2 1 3 1 4 Digital Thermometer Item Specifications Clinical digital thermometer to check the temperature ofbody SSS IHumanoraluse O OOOO N Gof bo 4 Flat type wide thermometer safe to use no glass no mercury ag 3 1 Digital Thermometer Clinical Technical Specifications 4 2 4 3 4 4 4 5 4 4 Re Water proof for ease of cleaning S Shall works on battery There shall be low battery indicator S Shall provide battery Bidder to indicate the type of and number of battery to be supplied hall have facility of beep sound and switch off Accessories Spares and Consumables Single piece packing
99. s and consumables Accessories 5 6 6 6 Black and white video thermal printer with 50 rolls of high density recording paper 01 no DVD CD Recorder with DICOM media transfer O Ultrasound gel warmer 01 unit All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 Operating Environment Zz The product offered shall be designed to be stored and to operate normally under Power Supply Climate 5 1 2 l 2 3 Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Shall provide UPS of suitable rating with voltage regulation and spike protection for 30 minutes back up 7 Standards and Safety Requirements 741 Must submit ISO 13485 2003 AC 2007 AND Electrical safety conforms to standards for Electrical Safety IEC 60601 2 37 Medical electrical equipment 7 3 Part 2 37 Particular requirements for the basic safety and essential performance of ultrasonic medical E diagnostic and monitoring equipment 8 User Training S O Warranty S O 1 0 maintenance whenever required 2 1 Service Technical Maintenance manual in English List of important spare parts and accessories with their part number and costing 3 Certificate of calibration and inspection from factory
100. s resuscitation and monitoring needs Operational Requirements It shall operate on AC power supply and internal battery System Configurations 3 1 Defibrillator with complete accessories Technical Specifications gt W jN It shall be a manual defibrillator for internal and external defibrillation 3 Able to perform synchronized defibrillation and non invasive pacing therapy Defibrillation energy selection 4 5 Internal 5 not more than 50 J External monophasic 50 360J 4 7 Defibrillation function External Paediatric neonatal 2 20J System shall be user friendly lightweight and easily transportable 4 1 Waveform shape biphasic The defibrillator paddles shall be easily interchangeable among adult child infant and internal paddles It shall come with at least adult and paediatric paddles 4 12 Can be used for neonatal paediatric and adult defibrillation 4 13 The unit shall be able to perform defibrillation and monitoring by using disposable electrodes 4 14 Shall have an electrode contact quality indicator to minimize the risk of ineffective defibrillation Recharge time shall not be held longer than 10 seconds before discharge ECG monitoring function Shall have a 3 leads ECG Lead I II amp III monitoring capability protected from defibrillation by mean of ECG electrodes and through the paddles monitoring External biphasic 50 200J h gt pd N 4 15 4 16 4 17 S Pacin
101. sories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 Operating Environment 6 1 The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Suitable UPS with maintenance free batteries voltage regulation and spike protection for minimum 30 min back up shall be supplied with the system Standards and Safety Requirements Must submit ISO13485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA approved product certificate 73 Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment i Use raining e a a oo l Warrany O Ophthalmic set Item Specifications Standard Set CE or USFDA or TUV approved certificate Ophthalmic table No 1 2 3 4 Versatile operation table for Ophthalmic surgery and certain special procedures 7 Titting Forward amp Reverse Back Rest Section 30 Leg Section 20_ S S S S Minimum Height 610 mm No 2 3 e peel o E Lg 8l Ophthalmic Unit No Item Specifications 1 Required Ophthalmic features 2 One fully upholstered elegant ophthalmic ch
102. sories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan lel Nn 6 2 Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Standards and Safety Requirements 1 Must submit ISO13485 2003 AC 2007 for Medical Devices AND 2 CE 93 42 EEC Directives or USFDA approved product certificate Shall meet IEC 60601 2 50 Medical Electrical Equipment PART 2 Particular Requirements for the Safety of Baby Incubators 9 1 Comprehensive warranty for 2 years after acceptance oo y O es Ls o Sey 6l 8 ae Maintenance Service during Warranty Period 10 1 During warranty period supplier must ensure preventive maintenance corrective breakdown maintenance whenever required Documentation 1 User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing Certificate of calibration and inspection from factory Infant Portable Ventilator Item Specifications Unit to be used for child and infant ventilation during cardiopulmonary resuscitation and for ventilation during
103. ssories spares and consumables All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer 6 Operating Environment The product offered shall be designed to be stored and to operate normally under Climate Temperature Humidity etc for Sudan 9 Warranty S User s manual shall be supplied in English 8
104. t Item Specifications Standard Set CE or USFDA or TUV approved certificate K Nails Set No Item Specifications Standard Set CE or USFDA or TUV approved certificate Plaster Saw N Item Specifications 1 Description of Function z ve L1 These instruments are used in orthopaedic surgery for cutting of plaster of paris synthetic cast applied for fractured bones System Configuration l l l Storage case to accommodate the plaster cutter and other accessories All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan 2 Go Nn Power supply 220 240 VAC 50Hz Single Phase fitted with appropriate plug The power cable must be at least 3 metre in length Standards and Safety Requirements Must submit ISO 9001 or ISO13485 2003 AC 2007 for Medical Devices AND CE or USFDA approved product certificate Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment 6 2 l T Pee 7 7 1 1 2 bo Must provide user training including how to use and maintain the equipment oe 1 1 Comprehensive w
105. t intensity comparable to 300W Xenon Colour temperature 6000 degree Kelvin The intensity of light shall be continuously adjustable The adjustment shall be in both Manual and AUTO mode 4 15 Suction Unit Washer disinfector for disinfection of endoscopes both flexible and video endoscopes The unit shall be mobile on castors O Dimensions approx 100w x500d x 900mmh Weight 30kg Tray Capacity min 6 L Must have lockable castor wheels for easy amp smooth movement of trolley from one place to another place Must have hanger in built for hanging of scopes Accessories Spare Parts and Consumables Biopsy forceps 2pc one type each Injection needle for sclerotherapy 2pc Dialators 1 5 1 Accessories for Video Gastroscope Foreign body grasper 1 Accessories for Video Colonoscope Bite Block 1 piece per each scope Biopsy forceps 2 pc one type each Polypectomy snares 2 set Biopsy forceps 2 pcs one type each Foreign body removal forceps 1 pc Accessories for Video Duodenoscope Haemostastasis loops 1 pc Gastric Balloon Dilatation Device 1 pc 2 boxes of 100 pieces colour video printing paper All standard accessories consumables parts required for the proper operation of the above item shall be lincluded in the offer 9
106. t section The table shall be mobile on castors with efficient braking system for stability during surgery Table top must be constructed from a high pressure laminate to permit x ray penetration and fluoroscopy section must be operated hydraulically y Shall have a manual position selector whose location must be interchangeable between foot and head end The casings on the frame and centre supporting column must be made of hygienic stainless steel Mattress must be radio lucent and suitable for fluoroscopy 48 Dimensions approx 10 variations All table positioning i e height back section lateral tilt trendelenburg and anti trendelenburg except foot and head 18 Di Height 730 1040 mm Side tilt 15 degrees Back section adjustment 15 degrees to 70 degrees Head section adjustment 40 to 30 degrees detachable Maximum width 555 mm Length 1950 mm 2 3 4 5 6 3 5 1 5 Padded arm rest with straps pair with damps O Anesthesia screen with clamps O Side supports pair with clamps O Muster supports pair with clamps Accessories spares and consumables Hei o Tr Anti trendelenburg 25degree pO Maxi 5 51 Foot section adjustment 90 to 0 degree detachable Trendelenburg 25 degree Infusion rod with clamp All standard accessories co
107. tandards for electrical safety IEC 60601 1 General Requirements and IEC 60601 2 25 Safety of Electrocardiograms 1 Must provide user training including how to use and maintain the equipment Oy by oO 1 Comprehensive warranty for 2 years after acceptance 10 Maintenance Service During Warranty Period During the warranty period supplier must ensure preventive maintenance and corrective breakdown maintenance whenever required 11 Echo Ultrasound O e 9l Pa eal gt p eo N Item Specifications Description of Function Colour Doppler Echocardiography System is required to study the anatomical abnormalities and blood flow in the heart and associated vessels a Operational Requirements Latest generation Electronic Phased array Colour Doppler system with minimum 512 electronic independent 1 2 l 2 channels A Must be upgradable to next generation system on site 3 Colour Doppler System with all application packages quad loop for serial studies with high frame rate review 3 1 Harmonic imaging capability in all modes Tissue Contrast Anglo Integrated Stress Echo Package Digital Storage and Retrieval 01no 3 11 MHz Electronics Phased Array Probe for Vascular applications 01 ea Multi plane TEE Probe 4 8 MHz for Adult as well as Paediatric echocardiography A 5 10 MHz Electronic phased array probe for Paediatric cardiology as o ad Colour Printer 01n o o E B W Video
108. te unit Technical Specifications Bag must be made up of medical grade silicon latex free double layered which retain sensitivity and it must be resistant to rough use nlet end of the bag must have separate port for Oxygen supplement Outer port must be such that re breathing valve or non return valve can be attached 4 1 I It shall be autoclaveable 6 It shall be adaptable to all type of face masks 5 Accessories spares and consumables 1 5 S SR 6 Operating Environment gt gt S O temperature and relative humidity for Sudan 1 Must submit ISO013485 2003 AC 2007 for Medical Devices AND es S Warranty ST Documentation S Neonate Ambo Bag An Ambu Bag also known as a Bag Valve Mask or BVM or Ambu bag is a hand held device used to provide ventilation to a patient who is not breathing or who is breathing inadequately It shall be self inflatable and must have pop up valve non return valve attachment for oxygen tube amp oxygen reservoir 3 1 3 System Configuration Ambu bag complete unit d Technical Specifications 4 Bag must be made up of medical grade silicon latex free double layered which retain sensitivity and it must be resistant to rough use with infant face mask sizes 00 01 amp 02 Operating Environment 6 1 7 Standards and Safety Requirements 7 1 Must submit ISO13485 2003 AC 2007 for Medical Devices AND 7 The system offered must be designed to s
109. tion of Function The Syringe Infusion Pump provides uniform flow of fluid by precisely driving the plunger of a syringe down its barrel It provides accurate and continuous flow rate for precise delivery of I V medication in critical medical care Operational Requirements The syringe pump must be programmable user friendly safe to use and must have battery backup and comprehensive l Item Specifications 1 1 alarm system This must be able to integrate in the HIS System Configuration Syringe infusion pump with battery backup alarm and with complete accessories Technical Specifications 4l Flow rate programmable from 0 1 to 200 ml hr or more in steps of 0 1 ml hr with user selectable flow set rate option SAVE last infusion rate even when the AC power is switched OFF Bolus rate must be programmable to 400 500 ml hr or more with infused volume display Reminder audio after Jevery 0 5 ml delivered bolus SAVE last Bolus rate even when the AC power is switched OFF Keep Vein Open KVO must be available 1 0 ml hr or set rate if lower than 1 0 ml User must have choice to disable KVO whenever desired Selectable Occlusion pressure trigger levels selectable from 300 500 900 mmHg Must Work on commonly available 20 50 60 ml Syringes with accuracy of minimum of 2 or better Automatic detection of syringe size amp proper fixing Must provide alarm for wrong loading of syringe such as flanges Jout of slot disengaged plu
110. tools and cleaning and lubrication materials to be included in the offer Operating Environment The product offered shall be designed to be stored and to operate normally under Power Supply Climate d Temperature Humidity etc for Sudan Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in 62 length Zz Suitable UPS with maintenance free batteries with voltage regulation and spike protection for minimum 30 min back up shall be supplied with the system 7 Standards and Safety Requirements 7 1 Must submit IS013485 2003 AC 2007 for Medical Devices AND iy 2 CE 93 42 EEC Directives or USFDA approved product certificate E Electrical safety conforms to standards for electrical safety IEC 60601 1 General requirement for Electrical safety of Medical Equipment 8 User Training Must provide user training including how to use and maintain the equipment a Warranty 91 Comprehensive warranty for 2 years Maintenance Service During Warranty Period 104 During warranty period supplier must ensure preventive maintenance amp corrective breakdown maintenance whenever required o cell Documentation User Operating manual in English Service Technical Maintenance manual in English List of important spare parts and accessories with their part numbers and costing Certificate of calibration and inspection from factory 6 2 6 3 7 7 1 1 2 1
111. tor and safety thermostat take over indicator lamp LCD LED indicator 4 3 4 1 Interior w x h x d Approx 400mm x 400mm x 400mm Easy to clean interior made of stainless steel with supports 4 Temperature Range ambient to 250 oC Output available for data acquisition Hot Air Oven shall be mounted on suitable epoxy powder coated support stand having 4 robust 360 deg swivel lockable castor wheels for easy movement and repositioning 5 All standard accessories consumables parts required for the proper operation of the above item shall be included in the offer The product offered shall be designed to be stored and to operate normally under Power Supply Climate Temperature Humidity etc for Sudan Temperature Variation 1 ple JNIA gt oo Power supply 220 240V 50 Hz AC Single phase fitted with appropriate plugs The power cable must be at least 3 metres long 7 7 10 1 Supplier must accomplish proper installation and commissioning of the equipment on site 8 1 5 l 8 81 9 p LC U Beds Description of Function ICU Beds are required in the Intensive Care for comfort of the patient and to facilitate comfortable transfer to and fro 1 1 emergency OT Wards etc It is also required to carry out point of care procedures including radiological procedures at the bedside 3 1 Electrically and pneumatically operated ICU bed with matress 2 Should have X Ray translucent b
112. tore and be operated normally under the condition include Climate temperature and relative humidity for Sudan 8 Warranty S Comprehensive warranty for 1 year after acceptance 9 Documentation gt User s manual shall be supplied in English CE 93 42 EEC Directives or USFDA or TUV approved product certificate TUR set Item Specifications CE or USFDA or TUV approved certificate Anesthesia Machine Item Specifications Description of Functions t shall be an anaesthesia unit with pneumatically or electrically powered and electrically controlled ventilator Operational Requirements 2 2 It shall be suitable to be used for adult and paediatric patients 3 3 1 i iZers i 4 1 i i i 4 I I System Configurations It shall come with the main unit and two vaporizers one for isoflurane and the other for halothane Equipment safety standard should follow IEC 60601 document evidence shall be submitted for evaluation 4 2 On sturdy steel with anticorrosive powder coating trolley running on four antistatic wheels with brakes and drawers 2 2 3 34 _4 Technical Specifications _ S 41l Revolving support for possible inclusion of CO2 absorber 4A Gas inlet 3 inlets O2 N20 and Air Gas cylinder yokes O2 amp N20 4 6 Should come with accessories for connecting gas supply both from central supply as well as from cylinders It shall come with 6 flow meter columns 2 flow meter columns for each kind of g
113. transportation when necessary _No _ To have frequency control 1 150 bpm breaths per minute S _3 Tidal volume control 5 100m S 4finflation pressure monitor 0 to 100 cm H20 0 _5 Air mix control zero to 70 air mixture o 6 fAdjustable relief pressure with audible alarm 20 to 80 cmH20 S To be supplied with a sling to enable the user to carry the unit easily and a patient circuit 1 25m long 15mm single bore silicone hose Autoclavable The ventilator should be compatible with DC power cables for powering the ventilator from Ambulance Cigarette lighter power supply 11 Operating Environment The product offered shall be designed to be stored and to operate normally under Power Supply Climate ma Temperature Humidity etc for Sudan ne Power supply 220 240 VAC 50Hz fitted with appropriate plug The power cable must be at least 3 metre in length Must have at least 1 hour of built in battery back up for the complete ventilator including compressed Air Source No 1 2 3 4 5 10 1 11 1 11 2 Standards and Safety Requirements Must submit ISO013485 2003 AC 2007 for Medical Devices AND CE 93 42 EEC Directives or USFDA or TUV approved product certificate 12 3 Shall meet IEC 60601 2 50 Medical Electrical Equipment PART 2 Particular Requirements for the Safety of Baby Incubators Must provide user training including how to use and maintain the equipment Comprehensive warranty for 2 years afte
114. ure between 4000 4500 K Shall have colour rendering index in between 92 94 Shall have 99 heat filtrating l Item Specifications 1 Temperature increase on operating field shall not be more than 15 oC Radiant heat energy beam temperature shall not exceed 25 000 microwatts per square centimetre measured 1m from the light source The light offered shall have safety designed to prevent patient from burns especially during the ophthalmic procedures The light offered shall be certified safe to be used under ophthalmic procedures Working distance range focal length 70 130cm Depth of field with focused light gt 60cm Luminance field size 15 25cm diameter adjustable 4 12 7 aes 7 r e 4 Shall come with continuous dimmer continuous focus adjustment continuous field adjustment 13 14 15 16 17 4 4 18 4 19 4 2 4 21 4 22 4 23 4 24 4 25 Mobile Stand Shall be based on light weight easily moveable stable support with at least 4 casters with locking counter balance mechanism in order to ensure stability of light head in all positions and with swivel arm Caster must be medical chemical resistant Lithium ion built in rechargeable batteries with capacity sufficient for operating in battery mode fully charged for minimum of 3 hours 5 1fAccessories o OS D 1x spare halogen bulb o O 1 x spare halogen bulb 1 x spare set of fuses All standard accessories consumables and parts re
115. wel colon 1 The instrument used for this is called Gastro Duodeno and Colonoscopy Operational Requirements also be able to share one common camera system in order to promote sharing of such camera system and hence increase its utilisation All bidders must comply with this condition 3 System Configuration Video Gastro Duodeno Colonoscope with Camera system LED light source and with complete accessories Technical Specifications The video endoscopy system including camera system all video endoscopes and all other peripheral equipment 2 offered must be of the same BRAND and same MANUFACTURER All video endoscopes offered in this TSF must Insertion tube diameter of less than 10 mm Angulations of tip up at least 200 degrees and down 90 degrees with right and left movement of at least 100 100 degrees Inner diameter of instrument channel more than 2 5mm Working length not less than of 1000mm Total length not less than of 1300mm Must be compatible with the video system specified Video Colonoscope Field of View 130 140 deg Observation Range 5 100mm O Distal end diameter of not more than 13 mm O Direction of view must be zero degree O Insertion tube diameter of less than 12 mm Angulations of tip up at least 180 degrees and down 180 degrees with right and left movement of at least 160 160 degrees Inner