        AQUADRY 28 service manual engx
         Contents
1.    SWI1 Turn on Stand by key   SW2 Mode selection key    SW3 Humidity increasing key  value between 30  and 90     SW4 Humidity decreasing key  value between 30  and 90     SWS5 Room humidity temp  key    DL1 DL2 DL3 DL4  In normal working operations they display the Set Temperature and Set Relative  Humidity values respectively  according to the function selected  both in blinking mode and with duration of  5 seconds Furthermore following information can be shown     30    90   30    90  blinking     __  99   Setup mode  frost accumulation temperature    set poi    Setup mode  end of defrosting temperature  20   40 Setup mode  set point temperature in combined mode       OLIMPIA  SPLENDID    3 Buzzer and backlight Ci       Five short pulses Autotest and Set up modes activation    Intermittent for 15 seconds Tank micro switch opening    Probe malfunctions       Evaporator exchanger low temperature malfunction      As soon as the tank switch opens the unit has to switch off all the active loads  except the fan whose  switching off has to be delayed by 30 seconds   switch on of the corresponding symbol in fixed mode  and enable an intermittent acoustic signal for 15 seconds  press any key with the acoustic alarm active or  re close the microswitch to silence the alarm      The board confirms any command by a brief acoustic signal and switching on the LCD backlight for 10  seconds     4 Working modes description    4 1 STAND BY MODE   This mode can be selected by pressing SWI ke
2.  end temperature is reached     5 4 Inhibition of Tank Full switch   The tank full switch is ignored  this function is accessed only if the level switch is open  tank full or absent   by keeping the SW3 SW4 keys pressed for 3 seconds  the S4 symbol blinking indicates that the function 1s  active  The function is automatically terminated when the level switch is closed     5 5 Autotest mode  When the unit is in Stby mode  by pressing the keys SW4 SWS5 for 3 seconds  SW4 first   the following  sequence 1s started      all LCD symbols are switched ON for 3 seconds      the SW release 1s shown for 3 seconds      both fan and compressor are switched ON  the LCD shows the code At on digits DL3 and DL4 and   evaporator probe temperature on digits DLI and DL2      The compressor remains ON continuously  regardless of the RH set point and tank microswitch  condition  the defrosting function is disabled and compressor can be powered even if Cf minutes have  not elapsed from previous compressor shut down    The tank level symbol  S4  is switched ON if the tank is absent full  microswitch open   and remains OFF if  the tank is present  board input closed     By pressing the key SW5 the unit shows the measured room air temperature and relative humidity values   like during normal operations    Press the stand by key  SW1  or disconnect the power supply to quit the auto test mode     OLIMPIA  5 6 Setup mode SPLENDID    By pressing the keys SW5 SW3 for 3 seconds in stand by mode you access 
3. 1 Data sheet    Descrizione  Capacit   di deumidificazione  1   Capacit   di deumidificazione  2   Volume deumidificabile  Potenza di riscaldamento  Potenza assorbita in deumidificazione  1   Assorbimento nominale in deumidificazione  1   Potenza assorbita massima in deumidificazione  2   Assorbimento massimo in deumidificazione  2   Potenza assorbita massima in deumidificazione  U L U    Assorbimento massimo in deumidificazione  U L U      Potenza assorbita max  in deumidific  riscaldamento  L L U      Assorbimento max  in deumidific  riscaldamento  L L U     Grado di protezione   Max pressione di esercizio  lato alta pressione  Max pressione di esercizio  lato bassa pressione  Velocit   di ventilazione   Capacit   tanica   Fortata aria  max    Dimensioni prodotto  Larg  x Alt  x Prof    Dimensioni imballo  Larg  x Alt  x Prof     Livello sonoro   Peso  senza imballo    Peso  con imballo    Gas refrigerante   carica   Cavo di alimentazione   N7 poli x sezione mmq    Alimentazione   Tensione di alimentazione minima massima  Fusibile   Marcature di conformit     Enti certificatori    CONDIZIONI LIMITE DI FUNZIONAMENTO    Temperature di esercizio massime  Temperature di esercizio minime    AQUADRY 28       Dehumidification capacity  1   Dehumidification capacity  2   Dehumidificable volume  Heating capacity  Power absorption in dehumidifcation mode  1   Nominal absorption in dehumidification mode  1   ax  power absorption in dehumidification mode  2   ax  absorption in dehumidi
4. fication mode  2   ix  power absorption in dehumidification mode  U LU    ax  absorption in dehumidification mode  U L U        ix  power absorption in dehumidif  heating mode  U LU    ax  absorption in dehumidif heating mode  U LU    Protection level  Maximum operating pressure  high pressure side  Maximum operating pressure  low pressure side  Fan speeds  Tank capacity  Air volume   max    Dimensions  WxHxD   Packing dimensions  WxHxD   Noise level  Weight  without packing   Weight  with packing   Refrigerant gas   charge  Power cable   N   pole x section mmg    Power supply  Power supply min   max    Conformity Mark  Certification Mark    Haximum operating temperature  Minimum operating temperature    TEST PARAMETERS    OLIMPIA  SPLENDID       Unita di misura   Unit Valori   Value    W24h  W24h    IP 21    20  ee 25  A 28   iva   dee   nia   oss  a Ge    42  T  264  T     mm    ss0rero0s    W  A  A  A  A   290x545x 395    Mpa     db A     SI     a   ee    Tipo Type   kg Ri34a   0 160    0    a  V F Hz 250  1 50     U L U   DB 35  C   WB 31  C   LIL U   DB 2  C   WB 1  C     1  DB 27  C   WB 21  C   27  C   60  RH     2  DB 32  C   WB 29  C   32  C   80  RH         OLIMPIA  SPLENDID       2 Control panel keys and display    DL3 DL4  Relative  Humidity    DL1 DL2  Room air    0 a  temperature I HH HH     view    ru  E       S1 Dehumidification   S4 Full water tank No water tank If blinking with frequency of 1 25Hz continuous discharge function is  enabled   S6 Purifying mode
5. ime equal to Cf  measured from the compressor shut down   at the end of which the compressor and the fan  are switched back on again if the relative humidity value is greater than the set point  3      OLIMPIA  SPLENDID       The relative humidity  RH  set point can be adjusted from 30  to 90  in steps of 5   By pressing the UP   SW3  or DOWN  SW4  keys the set point value is increased or decreased by 5      5 Other functions and modes    5 1 Auto recovery function   The ON OFF status  the set point  the operating mode  including tank switch inhibition  are saved in  EEprom memory  After a black out or a power mains failure the unit recovers all operations previously set  without observing any compressor Cf OFF time     5 2 Compressor switching  Compressor can be switched ON only when Cf minutes have elapsed starting from previous compressor  shut down     5 3 Defrosting function   When a frost condition occurs  evaporator temperature  lt  Ft and compressor ON  the compressor remains on  for a maximum time equal to Co minutes  then defrosting takes place  fan on at minimum speed  resistor not  active  compressor off  which terminates when the pre set temperature St is reached  evaporator temperature   gt  St   compatibly with the minimum compressor OFF duration Cf  defrosting interval cannot be shorter than  Cf minutes     If frost condition is detected and RH set point is reached within Co minutes  the compressor has to be  stopped but the fan remains on until the defrosting
6. ittent acoustic signal is enabled  which can be silenced by pressing any key  with  duration of 15 seconds    Reset of this alarm status occurs automatically as soon as the evaporator temperature rises above the value  stored in parameter St     7 WIRING DIAGRAM      Flecironie card ipower    Mumialytamperslue  sensor card    Floctronie card contra    Fundy tampar mira  Sanso     Eyaporalor sensar     Compressor thamai  eutout  RY102   Compressor relay  EYi04   Fan relay  Mi    Motorciven  COT BSS OF  Me   Fan  ST   Tank fulimissing  microswiten  Sagi   Signal key for the  humidi OT  tamperalure detected  Sale   Desiredhumidiy  decrease key  SHa   Daskedhumdiy  increase key  SAN   Gwiteh anvetand by kay  S405  Operating mode selection    fo 62    DE    key  Ti   Tansiomer  ZI   lt  Compressor capacitor    AQUADRY 28    WFE AC       OLIMPIA  SPLENDID       
7. the setup  by pressing key SWS  you go to the next parameter  SW5 SW3 or SW5 SW4 increase or decrease the value  when the SW5 key    is released the current value is stored in the memory        In order to quit the setup mode  press the SWI key or disconnect the power supply   The default values shown in the table below are programmed during the electronics test process     Range De  Mnemonic Parameters set Description  scheduled  20   50 min Compressor in defrosting ON time    tC 20     40  C 26 Temperature set point in combined mode       6 ALARMS    6 1 PROBES ALARM   Any failures in the probes are displayed by Hr or tE blinking for the humidity sensor probe ambient probe  and evaporator probe respectively  in the case of a failure in the probes all the loads are de activated  except  the fan whose switching off has to be delayed by 30 seconds  and an intermittent acoustic signal is emitted   which can be silenced by pressing any key  with duration of 15 seconds    The humidity probe signals the failure even if it measures a room relative humidity percentage below 22   a  condition in which the unit must be deactivated  Operation is automatically restored as soon as the relative  humidity rises back above 22      6 2 LOW TEMPERATURE ALARM   If after 30 minutes of operation in defrosting mode  compressor stopped and fan working  the evaporator  temperature does not exceed St  then the fan is stopped  the display shows the alarm code LO blinking and  an emission of an interm
8. y on the control board  and is signalled as shown on par  2    In this condition  if the key is pressed again  all the functions previously selected are restored  operating  mode  set point  etc      When switching to stand by mode all board outputs are switched OFF  but if compressor was active  the fan  only continues to run for 30 seconds further before stopping    In STAND BY mode  and only in this mode  it is possible to enter the parameter programming mode where  new parameter values can be stored in eeprom  see related paragraph      4 2 AIR CLEANING MODE   When selected by SW2  see par 2  the fan 1s switched on  while is switched off only in the following cases   the tank switch opens or any alarm occurs    When this function is selected  the symbol S6 is switched ON  while digits DL DL2 and DL3 DL4 show the  actual room temperature and Relative Humidity values acquired  button SW5 is disabled     The fan speed is the only one available  power board output FAN1      4 3 DEHUMIDIFICATION MODE   Selected by SW2 and signalled as shown on par  2    Compressor and fan  power board output FAN1  are switched on if the minimum OFF time  Cf  has elapsed  and if the relative humidity value is higher than the set point   3   compressor and fan remain ON as long  as the relative humidity value is above the set point     3   when below the set point     3   compressor and  fan switch off  the fan is switched off 30 seconds later than the compressor  and remain off for a minimum  t
    