1. 7 joe j EO 5 In the event of fire the detector hose bursts When the pressure drop in the detection system has fallen to approx 10 bar a valve on the extinguisher cylinder is activated and the system is released The pressure switch on the detector cylinder sends an alarm to the driver position With a semiautomatic system depending on the version that has been installed either the vehicle contact key shall be turned off or the handbrake pulled on or the ladder lowered in order that the extinguishing shall be activated in the event of a fire The activation is delayed until this point with the help of a magnetic valve connected to the detector hose and this maintains the detector pressure to the extinguisher cylinder Note the vehicle manufacturer s appendix for information about the activation that is used On delivery of the system the detector cylinder shows approx 20 24 bar and is filled with detector fluid and a propellant The propellant consists of nitrogen gas The pressure can be read off on a manometer and shall be within the green sector If the pressure falls below 14bar which means too low a system pressure the pressure Fogmaker International AB 4 8016 002 switch sends an alarm the same alarm as with a fire As an option there is a detector cylinder with an extra pressure switch that sends an alarm if the pressure falls below 7 bar which means that the system is released with a fire The detector cylinder h
2. User manual Fire extinguisher system for engine compartments Edition 2011 1 Hydro pneumatic activation _ Mechanical activation Electrical activation Marine applications Fogmaker International AB Postal address Delivery address Tel 46 470 77 22 00 Box 8005 Sandvagen 4 Fax 46 470 77 22 10 350 08 V xj 352 45 Vaxjo info fogmaker com www fogmaker com Part no 5016 002 1 General description This vehicle or machine is equipped with a fire extinguisher system for the engine compartment and possible separate heating areas Depending on which version that is installed the extinguishing is activated hydro pneumatically mechanically or electrically In certain cases the extinguisher system can have both mechanical and electrical activation When extinguishing the extinguishant is sprayed through nozzles that break down the fluid into pillar shaped mist clouds that cool the temperature and force the air out The extinguishant is mainly based on antifreeze water The extinguishing time is normally between 3 5 seconds and the effective time is 50 75 seconds 2 Pertaining components The components in the extinguisher system that are common irrespective of the type of activation are extinguisher cylinder 1 located in a separate area hydraulic hose 2 pipe system with nozzles 3 located above the engine 4 Fogmaker International AB 2 8016 002 For systems with hydro pneumatic activation or electric
3. activation there are often in the driver s position alarm lamps and alarm sirens that give signals in the event of a fire or as an option warn for low pressure in the extinguisher cylinder or the detector cylinder or in the event of smoke emission There may also be an alarm panel with optical or acoustical signals or with voice messages The alarm panel can also have functions such as automatic engine shut off releaser delay fuel and main power shut off Alarm lamps sirens and test buttons can also be integrated into existing systems in the vehicle e g CAN bus multiplexer see the vehicle manufacturer s manual 2 1 Hydro pneumatic activation Hydro pneumatic activation takes place semi or fully automatically without any power supply The activation takes place with the help of a pressurized fluid filled detector hose containing polymer 1 mounted in the upper part of the engine compartment and connected between a detector cylinder 2 and the extinguisher cylinder 3 The detector cylinder is normally located in the same compartment as the extinguisher cylinder not in the engine compartment Fogmaker alarm lamp and alarm buzzer in the event of fire or low pressure in the detection system 5 Fogmaker alarm lamp and alarm buzzer for low pressure in the extinguisher cylinder optional 5 optical smoke alarm optional 6 vehicle alarm panel e g CAN bus multiplexer 7 Fogmaker International AB 3 8016 002
4. within a short time after the fire For the sake of safety the engine should be protected by filling a little oil and turning over the engine a couple of revolutions with the starter motor In order to avoid corrosion on metal parts and unwanted short circuiting in the electrical system sanitation shall be carried out as soon as possible This is done by rinsing with fresh water preferably with medium high pressure Use Fogmaker washing fluid otherwise a film that collects dirt can remain Always take notice of the vehicle manufacturer s instructions for engine washing Fogmaker International AB 12 8016 002 8 Daily inspection of the extinguisher system Check that possible lamps for low pressure in the extinguisher cylinder or detector cylinder are not lit Check that the pressure in the extinguisher cylinder and the detector cylinder 1s within the green sector on the manometers Control is discontinued for the pressure switches on the detector and extinguisher cylinders 9 Annual control The extinguisher system shall be controlled once a year by authorized personnel in accordance with the inspection report See service manual for detailed instruction and detailed form 10 5 year service and 10 year overhaul Every fifth year the extinguishant shall be exchanged due to the characteristics of the product Every tenth year the extinguisher cylinder shall undergo an overhaul where the extinguisher cylinder will be disassembled an
5. as a tap that shall be open when the system is active The working temperature for the cylinder should be between 30 65 C Pressure switch 14 bar standard Manometer Gauge Outlet Tap in open position Pressure switch 5 bar option All pressure switches is type NO which means that they will open when the pressure drops As an option there is also a manual and electric punch that is mounted on the detector hose With the help of this the driver can manually trigger the system by cutting off the detector hose Fogmaker International AB 5 8016 002 2 2 Mechanical activation An extinguisher system with mechanical activation is released manually with the help of one or more pull handles that are connected to the extinguisher cylinder valve with wires The pull handles are normally located in the driver position and on the outside of the vehicle The handles are equipped with shackle locks that can be sealed The handles are marked with labels E Fogmaker International AB 6 8016 002 2 3 Electric activation The extinguisher system with electric activation is triggered either manually from a push button normally located in the driver position semi automatically or fully automatically with the help of a detector cable or smoke sensors connected to an alarm panel With a semiautomatic system depending on the version that has been installed either the vehicle contact key shall be turned off or the handbra
6. d checked for wear and damages 5 year service and 10 year overhaul may only be carried out by authorized personnel Fogmaker International AB 13 8016 002 Appendix 1 The following shall be documented by the vehicle manufacturer or by the installation technician after an installation date Installation technician Person company sce a oo Registration no Chassis no detector cylinder Bar on delivery Pressure Bar on delivery Serial no extinguisher cylinder Yeal fF S O Year 2 o S O Year3 ff Year 4 o d Year 5 Revision ff Year 6 fF S O Year 7 ff Year Bf Year 9 fF S O E ss Year 10 Revision In order that the guarantee shall apply this page and the first page shall be copied and sent to Fogmaker See first page for contact information Fogmaker International AB 14 8016 002
7. ing or when transporting the extinguisher when it is pressurized The screw prevents unintentional activation of the extinguisher It is absolutely forbidden for non authorized personnel to take any action on the extinguisher cylinder primarily when it is pressurized The pressure in the cylinder can then be released and can with great power injure a person seriously Fogmaker International AB 9 8016 002 3 Alarm test The fire alarm shall always be tested before the work period commences Press the test button with the engine fire lamp When the test button is depressed the lamp shall be lit and an alarm sound shall be heard in the driver position 4 In the event of a smoke alarm Smoke alarm 3 In the event of a smoke alarm the lamp on the sign Smoke alarm will be lit and a constant sound will be heard Check the passenger compartment for the cause Fogmaker International AB 10 8016 002 5 In the event of a fire In the event of a fire the red lamp marked with engine fire is lit and the alarm siren gives an intermittent sound If no fire has occurred and the system has not been triggered it indicates that there is too low a pressure in the extinguisher cylinder or the detector cylinder Contact service personnel workshop immediately If the vehicle is in premises with inflammable material move it if possible Shut off engines and fans Turn the contact key and the main power off If possible close
8. ke pulled on or the ladder lowered in order that the extinguishing shall be activated in the event of a fire The activation is delayed until this point with the help of a magnetic valve connected to the detector hose and this maintains the detector pressure to the extinguisher cylinder Note the vehicle manufacturer s appendix for information about the activation that is used Voltage 12 30 VDC Manual power F Fogmaker International AB 7 8016 002 2 4 Extinguisher cylinder On delivery the extinguisher cylinder is filled to approx 105 bar pressure The propellant consists of nitrogen gas The pressure can be read off on a manometer and shall be within the green sector The extinguisher cylinder is also available in a version with two connected cylinders It can be located in a red protection box As an option there is a pressure switch that gives an alarm if the pressure falls below approx 80 bar The working temperature of the cylinder must not exceed 65 C See the round blue label for the anti freezing durability of the cylinder Pressure switch Manometer L 80bar optional gauge N Release valve Fogmaker International AB 8 8016 002 Safety screw ren id Safety valve Cover screw Hole for safety and cover screw Older valve New valve The extinguisher has a safety screw hanging on a wire when the system is active The safety screw shall always be inserted before a service installation dismantl
9. the cover to the engine compartment if it is open For systems with manual activation with wires break the seal lift the safety shackle and pull powerfully on the wire handle For systems with manual activation with a punch pull out the safety pin then press hit the release button heavily Shut off the fuel supply to the engine If required use a hand extinguisher Keep the engine cover closed for at least 5 minutes Contact service personnel contact the fire service if necessary Fogmaker International AB 11 8016 002 6 Low pressure alarm In the event of an alarm for low pressure in the detector cylinder or extinguisher cylinder contact service personnel 7 Action after a fire The fire alarm will sound until the alarm is actively shut off This is done by contacting authorized service personnel For systems with the Fogmaker bus alarm the alarm signal can be shut off by removing the cover of the pressure switch on the extinguisher and by twining together the two electrical cables The pressure switch contacts on the detector cylinder are separated and strapped Do not start the vehicle before the cause of the fire has been established and corrected The extinguishant does not normally affect the function of the engine Starting difficulties can however occur for diesel engines since the extinguishant contains water It is worth considering that the extinguishant can cause corrosion damage if the engine is not run