Home
Transmission Test Sets
Contents
1. A2 F MUX 23 t p d e 05900900000000900900009 VIO SUMMING 1 eo Service 7 5 HP 8514B and 8512A Test Sets 7 6 Service HP 8514B and 8512A Test Sets Miscellaneous Performance Tests Adjustments Manual Backdating HP 8514B and 8512A Test Sets Performance test information and procedures are located in the Performance Test section of the HP 8510 System Manual and volume 2 of the HP 8510A manual set Note that the HP 8510B performance test software supplied with the System Manual is required to test the HP 8514B up to 20 GHz The HP 8514B and HP 8512A have one adjustment only the sample assembly adjustment The procedure is documented the HP 8510 Service Manual in the section titled Adjustments It is also in the Test Set Adjustments section in volume 2 of the HP 8510A manual set The adjustment is software guided This adjustment should be performed only if the need to do so is firmly established A poor adjustment is worse than none at all Thus the software driven adjustment procedure begins with a check of the sampler in question to establish the need Do not perform the actual adjustment if the sampler passes the check Manual backdating is not required for this manual set This manual
2. 2 point pozidriv 1 point pozidriv 5 16 inch torque wrench 10 in Ib anti static mat wrist strap clip lead 9 16 inch nut driver 1 2 inch torque wrench 25 in Ib 3 5 mm connector gauge connector cleaning kit 1000 20 watt resistor 1 inch torque wrench 72 in Ib all components all components all components all components all components capacitors connector repair connector repair connector repair connector repair capacitor removal coupler removal 8710 0900 8710 0899 8710 1655 9300 0797 9300 1257 any supplier 8720 0008 8710 1581 1250 1862 92193Z 0819 0019 MTB 100 7216 1 Order from Mountz Company 1080 North 11th Street San Jose CA 95112 Test Set Troubleshooting 5 11 5 12 Test Set Troubleshooting HP 8514B and 8512A Test Sets Switch Attenuators Fan Splitter Transformer F Regulator Board a Sampler a Sampler Capacitors b Sampler Port 1 Bias Coupler Port 2 VTO b Sampler Coupler Bias Not Visible 156 HP 8514 8512A Test Sets Test Set Troubleshooting 5 13 Figure 5 6 1 Bias Tee 2 Coupler 3 Switch Splitter NOTE General Component Location Diagram 1 Desolder the wire connected to the bias tee 2 Loosen the nuts on both sides of the bias tee 3 Disconnect the semi rigid cable from the bias tee and remove the tee from the test set 1 Remove the bias tee as described in procedure 1 2 Remove th
3. 3 15 ProCedute eu ER Senden 3 15 4 Specifications Mechanical Specifications 4 1 Supplemental Characteristics 4 2 5 Test Set Troubleshooting Contents 2 HP 8514B and 8512A Test Sets Test Set Temperature ete eee eet s 5 2 Check Connections loose broken crimped etc 5 2 Check Power Supply Regulator Fuses and Switches 5 3 A15 Regulator Board Assembly 5 3 PUSES n C eet eo ec utn 5 3 Address Switches 5 3 Test Set Self Test Indicators 5 4 If Self Test Falls Run 5 4 Configuration 2 22 22 2 5 5 Check VTO Driver LO Hyde a ex 5 6 Test Set Troubleshooting Using Time Domain 5 7 Test Set Assembly Replacement 5 9 Equipment Needed But Not Supplied 5 11 Bias sace det area os ate tees dade e de tios les 5 13 2y Coupler ie eee ees Ae e DR A ERU 5 13 3 Switch Spltter eene et Den De de eot ie leben 5 13 4 Frequency Converter 5 14 hed ent elas Wie Qr
4. DRIVE PORT 2 PHASELOCK a2 REDEFINE DONE to observe the b1 thru power level trace The trace should resemble Figure 3 4 HP 8514B and 8512A Test Sets Operation 3 7 b2 Thru Test 6 Leave the thru connection of step 4 connected Press PARAMETER MENU USER 2 b2 REDEFINE PARAMETER DRIVE PORT 1 PHASELOCK a1 REDEFINE DONE to observe the b2 power level trace The trace should resemble Figure 3 4 Make sure that you redefine the parameters to the original conditions for al bl a2 and b2 7 If any of the traces are not within the specified limits check all of the connections and repeat the above procedure If symptoms persist refer to the Service Overview section of the HP 8510 Service Manual or volume 4 of the HP 8510A manual set 3 8 Operation HP 8514B and 8512A Test Sets HP 8512A Operator s Check NOTE All of the following HP 8512A CRT traces should decrease from 20 5 dB at 0 5 GHz to 32 5 dB at 18 GHz Figure 3 4 al Test b1 Reflection Test b2 Thru Test HP 8514B and 8512A Test Sets Typical Operator s Check CRT Power Level Trace 1 Press PARAMETER MENU USER 1 a1 to see the channel al power level trace 2 Connect an open a short to port 1 3 Press USER 4 b1 to observe the b1 power level trace The trace should resemble Figure 3 3 4 Connecta thru a 20 dB attenuator and test port return cable between port 1 and port 2 5 Press PAR
5. Blackburn Victoria 3130 Australia 61 3 895 2895 Canada Hewlett Packard Canada Ltd 17500 South Service Road Trans Canada Highway Kirkland Quebec H9J 2X8 Canada 514 697 4232 China China Hewlett Packard Co Ltd 38 Bei San Huan Road Shuang Yu Shu Hai Dian District Beijing China 86 1 256 6888 Japan Yokogawa Hewlett Packard Ltd 1 27 15 Yabe Sagamihara Kanagawa 229 Japan 81 427 59 1311 Singapore Hewlett Packard Singapore Pte Ltd Alexandra Post Office Box 87 Singapore 9115 65 271 9444 Taiwan Hewlett Packard 8th Floor 337 Fu Hsing North Road Taipei Taiwan 866 2 712 0404 HP 8514B and 8512A Test Sets Safety Considerations General Safety Symbols WARNING Review this product and related documentation to familiarize yourself with safety markings and instructions before you operate the instrument This product has been designed and tested in accordance with international standards The WARNING notice denotes a hazard It calls attention to a procedure practice or the like that if not correctly performed or adhered to could result in personal injury Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met CAUTION The CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly performed or adhered to could result in damage to the product or loss of
6. KEYSIGHT TECHNOLOGIES Keysight 8514B S Parameter and 8512A Reflection Transmission Test Sets Notice Hewlett Packard s former Test and Measurement business became part of Agilent Technologies in 1999 and then Keysight Technologies in August 2014 This document is provided as a courtesy but is no longer kept current and thus will contain historical references to Agilent HP or Hewlett Packard For more information go to www keysight com Operating and Service Manual Notices Keysight Technologies 1996 2014 No part of this manual may be reproduced in any form or by any means including elec tronic storage and retrieval or translation into a foreign language without prior agree ment and written consent from Agilent Tech nologies Inc as governed by United States and international copyright laws Manual Part Number 08514 90051 Edition October 2014 Published by Keysight Technologies Inc 1400 Fountaingrove Pkwy Santa Rosa CA 95403 USA Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED AS IS AND IS SUBJECT TO BEING CHANGED WITHOUT NOTICE IN FUTURE EDI TIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KEYSIGHT DISCLAIMS ALL WAR RANTIES EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MER CHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE KEYSIGHT SHALL
7. 1 7 Accessories Supplied 1 7 Accessories Available 1 7 Calibration Verification and Adapter Kits 1 7 RE Cables dene RE rs e be es 1 7 Transistor Test Fixture 1 8 Operating and Safety Precautions 1 8 Electrostatic Discharge Information 1 8 Reducing ESD Damage 1 9 Operating Power Level 1 10 SEVICE i aed teed eg Late re eee 1 10 HP 8514B and 8512A Test Sets Contents 1 Additional Equipment 1 10 2 Installation IntrOduCtiotl rester eq aor ester bw ose en a See 2 1 Initial Inspection he RE RR ede 2 1 Environmental Considerations 2 2 Operation and Storage 2 2 Preparation for Uses boda eb MP e iR 2 5 Positioning the Test Set 2 5 Connecting the Test Set 2 5 Mating Connectors 2 5 Power and Control Connections 2 5 Signal Path Connections 2 6 Anti Rotation Clamps HP 8514B 2 6 Packaging iu ciue buste ste uon b tudo et nont de b Delos 2
8. A19J3 1251 7939 1 CONN POST TYPE 100 PIN SPCG 14 CONT A19J3 DOES NOT INCLUDE A19MP3 A19J4 1251 6868 CONNECTOR 5 PIN M POST TYPE A19J5 1251 6868 CONNECTOR 5 PIN M POST TYPE A19J6 1251 6868 CONNECTOR 5 PIN M POST TYPE A19J7 1251 3825 1 CONNECTOR 5 PIN M POST TYPE A19J8 1200 1304 2 IC SOCKET 14 PIN 6 4 Replaceable Parts HP 8514B and 8512A Test Sets Table 6 1 8514B Replaceable Parts Continued Part Number Qty Description A19J9 1200 1304 2 IC SOCKET 14 PIN A19R1 0764 0015 2 RESISTOR 560 5 2W MO TC 0 200 A19R2 0764 0015 RESISTOR 560 5 2W MO TC 0 200 A19R3 0764 0016 2 RESISTOR 1K 5 2W MO TC 0 200 A19R4 0764 0016 RESISTOR 1K 5 2W MO TC 0 200 A19R5 0757 0394 RESISTOR 51 1 1 125W TC 0 100 A19R6 0757 0394 RESISTOR 51 1 1 125W TC 0 100 A19XA2 1251 7882 5 CONNECTOR PC EDGE 2 ROWS A19XA3 1251 7882 CONNECTOR PC EDGE 2 ROWS A19XA4 1251 7882 CONNECTOR PC EDGE 2 ROWS A19XA5 1251 7882 CONNECTOR PC EDGE 2 ROWS A19XA6 NOT ASSIGNED A19XA14 A19XA15 1251 7882 CONNECTOR PC EDGE 2 ROWS A20 08513 60006 1 BOARD ASSEMBLY HPIB INTERCONNECT MISCELLANEOUS ELECTRICAL PARTS AT1 8493C 1 3 5 MM 20 DB ATTENUATOR AT2 8493C 1 3 5 MM 20 DB ATTENUATOR AT3 SEE Figure 6 11 B1 08513 20031 1 FAN TBAX 34 CFM 115V 50 60 HZ 1 5KV DIEL C1 0160 4311 1 CAPACITOR FXD 022UF 80 2096 100VDC CER DS1 1990 0858 2 LED LAMP LUM INT 15UCD IF 25MA MAX DS2 1990 0858 LED LAMP LUM INT 15UCD IF 25MA MAX E
9. If it is damaged keep it until you have checked the contents for completeness The contents are listed and illustrated in Figure 2 1 In addition check the test set mechanically and electrically If the test set and shipping container are undamaged passing the Operator s Check in the Operation section should suffice for incoming inspection If the test set does not pass the Operator s Check refer to the troubleshooting procedures in the service portion of this manual Alternatively call your local HP customer engineer If the shipping container is damaged perform the performance tests outlined in the HP 8510 manual set If the test set fails the performance tests or is damaged or defective keep the shipping materials and notify both the carrier and the nearest Hewleft Packard office The HP office will arrange for repair or replacement of the test set without waiting for settlement of the claim If any of the following accessories are not received with the test set notify your nearest HP office and the missing parts will be sent to you Installation 2 1 Environmental Considerations Operation and Storage To perform within specifications the test sets should be operated in temperatures between 0 C and 55 C with relative humidity less than 95 at 40 C dry bulb temperature maximum They may be operated at altitudes up to 4 500 metres 15 000 feet The test sets may be stored in temperatures from 40 C to 75 C with rel
10. Refer to your calibration kit manual for information on how to use your gauge HP 8514B and 8512A Test Sets Specifications 4 1 Supplemental Characteristics The supplemental characteristics listed in Table 4 2 and Table 4 3 are intended to provide information useful in applying the instrument by giving typical but non warranted performance parameters Table 4 2 HP 8510B 8514B Characteristics Test Ports Front Panel RF Input Connectors Rear Panel Connector type precision 3 5 mm male Impedance 50 ohms nominal Incident signal attenuation range 0 to 90 dB in 10 dB steps DC bias 500 mA 40 VDC maximum Damage input level gt 17 dBm CW Nominal operating power level 2 Frequency Operating Level 0 045 to 8 GHz 3 dBm 8 to 20 GHz 0 dBm Nominal connector nut size 20 mm Recommended torque 90 N cm 8 in Ib Connector type precision 3 5 mm female Damage input level gt 23 dBm Source power levels for reference channel phase lock Minimum 0 dBm Maximum 14 dBm Nominal connector nut size 8 mm Recommended torque Precision 3 5 mm 90 N cm 8 in Ib SMA 56 N cm 5 in Ib 1 Do not exceed 10 dBm to test port for proper operation 2 Available power in PRESET condition 4 2 Specifications HP 8514B and 8512A Test Sets Table 4 5 HP 8510B 8512A Characteristics Test Ports Front Panel RF Input Connectors Rear Panel Connector type 7mm Connector type preci
11. This pair of 3 5 mm connectors holds the reference port extension cable RPEC supplied used to equalize the length of the reference signal al sampler path with the test signal b1 sampler path When the DUT is connected to Port 1 with any of the recommended cables connect the long RPEC to Extension B When the DUT is connected directly to Port 1 connect the short RPEC to Extension B 13 RF Input This 3 5 mm connector receives RF energy from the source 14 Test Set Interconnect This connector is used only in test sets with option 001 It allows connecting another test set to the option 001 test set Up to four test sets can be serially connected to the HP 8510 The HP 8510 system automatically selects the IF output from the chosen test set for processing and display 15 J11 Test Set Interconnect This connector transmits the IF signal from the test set to the HP 85102 IF Detector It also transmits control signals bidirectionaliy 16 8510 System Bus Address Switch This five pole binary weighted switch sets the system bus address of the test set The binary weight of each pole is indicated on the rear panel as are the on and off positions Decimal twenty off off on off on from left to right is the default setting 17 J12 8510 System Bus Connector This connector is used for HPIB communications with the HP85101 display processor 18 Port 2 Bias HP 8514B only This female BNC connector is used to suppl
12. and 8512A Test Sets Replaceable Parts 6 33 w49 w39 Not Not 38 87 Shown W34 W38 W35 Shown W37 uu 0 56 4 8 Held to 1 Used Coupler by 4 Ea 50 Not Visible Figure 6 17 HP 8512A Miscellaneous Mechanical Chassis and Electrical Parts 6 34 Replaceable Parts HP 8514 8512A Test Sets 5 29 30 39 E32 5 PLACES E37 8 Heo EAD Bi 11 E31 E13 iia MN NOT VISIBLE Figure 6 18 HP 8512A Miscellaneous Mechanical Chassis and Electrical Parts HP 8514B and 8512A Test Sets Replaceable Parts 6 35 PORT 1 AG Dress Panel 56 E15 E42 B l Sub Panel E43 E37 PORT 2 Dress Panel E36 E17 E16 E35 e IT QO E18 E7 Sub Panel E37 Figure 6 19 8512A Port 1 and Port 2 Replaceable Parts Reference DM HP Part Number Qty Description Designation E42 5020 8541 9 0 0005 IN INNER SHIM 5020 8540 8 0 0010 IN INNER SHIM 08742 0005 3 0 0020 IN INNER SHIM E43 5021 0830 5 0 0010 IN OUTER SHIM 08742 0006 4 0 0020 IN OUTER SHIM 6 36 Replaceable Parts HP 8514B and 8512A Test Sets HP 8514B and 8512A Test Sets Replaceable Parts 6 37 6 38 Replaceable Parts HP 8514B and 8512A Test Sets Service This HP 8514B 8512A Service section consists of a wiring diagram keyed to Figure 6 7 on page 6 16 the component location diagram of the motherboard A19 Use these two tools as aids to troubleshoot motherboard t
13. safety and warranty considerations General Information 1 1 test set specifications 1 2 General Information HP 8514B and 8512A Test Sets Figure 1 1 8514B upper and HP 8512A Test Sets HP 8514B and 8512A Test Sets General Information 1 3 Verifying the Test Set NOTE The HP 8514B and HP 8512A have been designed to operate specifically with the HP 8510 network analyzer install the instrument turn to the Installation section of this manual To check the proper operation of the test set see the Operator s Check in the Operation section of this manual see the specifications of the test set refer to Specifications in the HP 8510B System Manual or General Information in volume 1 of the HP 8510A manual set To verify that the instrument meets its published specifications turn to the Performance Tests section in the HP 8510B System Manual or Volume 2 of the HP 8510A Operating and Service Manual The HP 8514B can be performance tested only to 18 GHz with the HP 8510A software To troubleshoot the test set refer to the Service Overview section and the Test Set Troubleshooting section of the HP 85 0B Service Manual or refer to the Service section in Volume 4 of the HP 8510 Operating and Service Manual Otherwise call your local Hewlett Packard office Instruments Covered by Manual 1 4 General Information You will find a two part serial number on the rear panel of the instrument
14. the standard HP 8514B includes four RF to IF converters to measure all four S parameters without reconnecting the DUT two 90 dB programmable step attenuators for changing in 10 dB steps the incident power level at both ports two bias tees for applying external dc bias to both test port center conductors In the High Forward Dynamic Range Configuration option 003 the Port 2 coupler is reversed to optimize dynamic range in the forward measurement direction Because the b2 sampler is connected to the coupler throughpath instead of the coupled arm there is less isolation between the b2 sampler and Port 2 and the b2 power level will be higher than b1 This configuration is better for wide dynamic range or reciprocal devices or components like filters cables or antennas where S is generally not measured However as a result of the lower isolation between the test port and the sampler sampler bounce appearing as an occasional spurious response related to the VTO frequency can be noticeable in this asymmetrical test set The HP 8512A reflection transmission test set uses one coupler for signal separation The standard HP 8512A has three RF to IF converters for making reflection 511 and transmission 521 measurements no step attenuators to internally change the incident power level nobias tees to apply external DC bias to the test port center conductors HP 8514B and 8512A Test Sets General Informat
15. 1 SCREW MACH 6 32 25 IN LG PAN HD POZI 6 2360 0123 7 SCREW MACH 6 32 625 IN LG PAN HD POZI 7 2420 0001 4 NUT HEX W LKWR 6 32 THD 109 IN THK 8 2420 0022 2 NUT SPCLY 6 32 THD 23 IN THK 354 OD 9 2510 0138 3 SCREW MACH 8 32 3 IN LG PAN HD POZI 10 2510 0270 1 SCREW MACH 8 32 3 25 IN LG PAN HD POZI 11 2580 0004 4 NUT HEX W LKWR 8 32 THD 125 IN THK 12 3050 0139 9 WASHER FL MTLC NO 8 172 IN ID 13 3050 0152 4 WASHER SHLDR NO 8 172 IN ID 438 IN OD 14 3050 0227 4 WASHER FL MTLC NO 6 149 IN ID HP 8514B and 8512A Test Sets Replaceable Parts 6 7 Table 6 1 8514B Replaceable Parts Continued 52 HP Part Number Qty Description 15 3050 0692 3 WASHER FL MTLC NO 10 202 IN ID 16 3160 0309 1 FINGER GUARD 17 08514 00011 1 REAR PANEL 18 0624 0099 37 SCREW TPG 4 40 375 IN LG PAN HD POZI 19 0624 0100 8 SCREW TPG 4 40 5 IN LG PAN HD POZI STL 20 1400 0757 2 CLAMP CABLE 25 DIA 1 WD PVC 21 2190 0011 8 WASHER LK INTL T NO 10 195 IN ID 22 2200 0105 13 SCREW MACH 4 40 312 IN LG PAN HD POZI 23 2200 0165 14 SCREW MACH 4 40 25 IN LG 82 DEG 24 2360 0115 62 SCREW MACH 6 32 312 IN LG PAN HD PCZI 25 2360 0119 6 SCREW MACH 6 32 438 IN LG PAN HD PCZI 26 2360 0333 12 SCREW MACH 6 32 25 IN LG 100 DEG 27 2510 0192 16 SCREW MACH 8 32 25 IN LG 100 DEG 28 2680 0129 8 SCREW MACH 10 32 312 IN LG PAN HD POZI 29 5021 8403 1 FRAME FRONT 30 5021 5804 1 FRAME REAR 31 5021 5837 4 STRUT CORNER 18 32 08505 20132 2 END PLATE
16. 6 3 Operation Introduction Ses RIXA Meets nee 3 1 Front Panel Features os ca de Me 3 2 Reat Panel Features ea aah ea eae eh ye AT 3 4 Operator s Check ead ERR ER Re 3 6 Equipment eee te tp A tage RS 3 6 Proced t ores tig oe el Reve RAS Rats 3 6 8514B Operator s Check 3 7 Sampler Test calx UI RU ave ur 3 7 bl Lhrudest izle t LIPieUbeTIDi ROW eEinetleisuM 3 7 b2 Thri dest coetu eae rV ri ese dits 3 8 8512A Operator s Check 3 9 al esto m tue iude Rak Casus 3 9 bl Reflection Test 2 12 44 via weit eis rre Gomis 3 9 b2 Thr Test 4 RE D etae eae EAA EET 3 9 Controlling Multiple Test Sets 3 10 Installation 3 10 i4 ots ada bei UR obtu 3 10 Initialization at Power up 3 10 Sel cting a Test Set IDE Re eR e ee 3 12 Test Set IF Switching 3 12 RF Switch Driver Commands 3 12 Measurement 3 12 Operational Checks 3 13 Performance Verification 3 13 Cable and Anti Rotation Clamp Installation
17. 8514B and 8512A Test Sets 9 Capacitor NOTE Set the test set upright and pull the metal and plastic cover off the capacitors 2 Turn the test set upside down and remove the bottom cover It is important to plug in the test set before performing step 3 Discharge each capacitor terminal large pozidrive screw on the bottom side of the test set through a high wattage resistor and clip lead to earth ground Each capacitor has two 2 terminals Discharge every capacitor terminal for 30 seconds To remove a capacitor remove the corresponding pair of screws and pull the capacitor out of the test set 10 3 5 mm RF Connector Repair Disassembly 9 16 INCH 9 16 INCH NUT LOCK WASHER INSTRUMENT PANEL Figure 5 7 HP 8514B and 8512A Test Sets Refer to Figure 5 9 on page 5 22 and the following text to repair 3 5 mm connectors BULKHI PIN AND BEAD GOLD NOSE CONNECTOR ASSEMBLY CONNECTOR WRENCH FLAT 1 2 Exploded Diagram of 3 5 mm Connector Remove any attached cables from the connector to be replaced Use a 1 2 in wrench to loosen the gold nose connector Remove the pin and bead assembly from the connector If only the pin and bead assembly needs to be replaced continue with step 6 From the inside of the test set use the 9 16 in nut driver to loosen the 9 16 in nut and remove the rest of the connector Test Set Troubleshooting 5 17 Assembly NOTE 4 Use the part numbers given below for replacement purpo
18. J11 TEST SET INTERCONNECT When the test set is inactive the IF signals appearing at J10 are passed through to and to the next test set or the HP 8510 The address of the test set can be changed manually from the HP 8510 front panel by selecting the ADDRESS of TEST SET function then entering the address of the test set and pressing x1 or it can be changed under program control using the HP 8510 appress command The HP IB address of a particular test set is set by address switches on the test set rear panel RF Switch Driver Commands A related feature of the HP 8510 is that when the HP 8510 ADDRESS of TEST SET function is changed a code sequence is automatically issued over the HP 8510 system bus to the device at the ADDRESS of RF SWITCH In the recommended configuration this device is an HP 11713A Attenuator S witch Driver which in turn controls one or more HP 33311C Coaxial Switches As shown in Figure 3 5 and Figure 3 6 these switches are used to select which of the test sets receive the RF output of the network analyzer source The exact command issued depends upon the new value of the ADDRESS of TEST SET function also shown in Figure 3 5 and Figure 3 6 Measurement Calibration 3 12 Operation After selecting the active test set perform the system calibration procedure as usual When you select a different test set make sure that you recall the Cal Set that applies to that test set Since the Cal S
19. Murau aM E iv Certification neci site bas Ee iv Warranty uoce el ela ee Seer ES iv ASSISTANCE M PL Support and vi Safety Considerations Jour Rue eve ue a a e ies and vii General ocn C DU er UU cL eL s vii Safety Earth Ground Before Applying Vili Typeface Conventions ix Declaration of X 1 General Information Introductio vu dete Ne erede o s 1 1 Verifying the Test Set 1 3 Instruments Covered by Manual 1 3 Description and Operating Characteristics of the Instrument 1 4 xo Me eile aa ei a RS Me Noel 1 5 Option 001 i hea 1 5 Option 002 HP 8514B only 1 5 Option 003 HP 8514B only 1 5 Option 002 003 HP 8514B only 1 5 Option 908 Locos ru ele wattle ette oC 1 5 Option 010 8 Sees CAR a ERR ER TEES 1 6 Option ITI ee atte ei 1 6 Option W03 Warranty Conversion 1 6 Option W30 Extended Service 1 6 IXCCeSSOTIGS usse cu ERA RE RAL AU RORIS
20. NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING USE OR PERFORMANCE OF THIS DOCUMENT OR OF ANY INFORMA TION CONTAINED HEREIN SHOULD KEYSIGHT AND THE USER HAVE A SEP ARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accor dance with the terms of such license Restricted Rights Legend U S Government Restricted Rights Software and technical data rights granted to the fed eral government include only those rights customarily provided to end user customers Keysight provides this customary commercial license in Software and technical data pursuant to FAR 12 211 Technical Data and 12 212 Computer Software and for the Department of Defense DFARS 252 227 7015 Technical Data Commercial Items and DFARS 227 7202 3 Rights in Commer cial Computer Software or Computer Soft ware Documentation Safety Notices CAUTION A CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditio
21. RR dv 5 15 6 Assembly 5 15 7 Regulator Board Assembly 5 15 8 Step Attenuator Assembly 5 15 9V Capacitor 34 ooo ehe t eR UR ten ts 5 16 10 3 5 mm RF Connector Repair 5 16 Disassembly nec nee M 5 16 Assembly eed 5 17 es 5 18 Disassembly ca ea 5 18 x corre eas t Mos i os denas 5 18 12 Port 1 3 5 mm Connector Port 23 5 mm Connector 5 19 Center Pin Repair Procedure 5 20 3 5 mm Nut Repair 5 20 13 Power Transformer ec Re RR we T 5 20 Unratioed Power Test 5 22 HP 8512A Test Set sod tks eee gS ER ee ee EE 5 23 al Ae tute et REA ret RE SUA e ERA rep es 5 23 bl Reflection Test c EMERGERE 5 23 b2 Lhr Test x tate cell tee Linea 5 23 8514B Test Seta i ME eL EE 5 24 Sampler Vest ERR AR RU RS Ee 5 24 DTT rU 2 lace t pr RR 5 24 b2 Thra Test bees bie ee bee Mee ees Bee Weeds 5 24 Next Step cse Ee cha Pe ae lnc s 5 25 If Any User Channel Looks
22. Reverse the following procedures to install parts Test Set Troubleshooting 5 9 CAUTION Electrostatic discharge ESD can damage or destroy electronic components All work on electronic assemblies should be performed at a static safe workstation Refer to Operating and Safety Precautions on page 1 9 for more information on preventing ESD 5 10 Test Set Troubleshooting The assemblies handled in this procedure are very sensitive to damage by static electricity They may or may not continue to function if subjected to an electrostatic discharge In any case an electrostatic discharge will impair the reliability of these assemblies Always perform the following steps in order 1 St 409 Ground the work area and yourself to prevent electrostatic damage to the microcircuits Turn the test set OFF Disconnect the power cord Remove the top cover Reverse the following procedures to install parts All 3 5 mm and 2 4 mm connections are torqued to 90 N cm 8 in lb Exercise caution when handling semi rigid coax cables They are easily bent HP 8514B and 8512A Test Sets Equipment Needed But Not Supplied HP 8514B and 8512A Test Sets The table below lists all equipment needed for replacing the various assemblies documented in the procedures in this section To locate all major assemblies in the test sets refer to the Replaceable Parts chapter of this manual Tools Used With HP Part Number
23. The first four digits and the letter are the serial number prefix The last five digits are the sequential suffix which is unique to each test set The contents of this manual apply directly to test sets with the same serial number prefix as the one s in the front of this manual If the serial prefix of your test set is not listed in the front of this manual your instrument differs from those documented in this manual The differences are documented in the yellow manual changes supplement supplied with the manual To keep this manual as current and accurate as possible Hewlett Packard recommends that you periodically request the latest manual changes supplement as it may contain replacement information as well as change information The supplement for this manual is keyed to the manual s print date and part number in the front of this manual and is available on request from Hewlett Packard HP 8514B and 8512A Test Sets Description and Operating Characteristics of the Instrument The combination of the HP 8514B test set with the HP 8510 network analyzer and source provides a system for making S parameter measurements over the frequency range of 45 MHz to 20 GHz This system is suited for making measurements on two port devices when it is inconvenient or inexpedient to physically reverse the DUT device under test to measure all four S parameters The HP 8514B uses two couplers for signal separation For measurements of active devices
24. a PORT 1 OPEN OR SHORT Figure 5 19 HP 8514B Option 002 003 b1 Reflection Signal Path 5 32 Test Set Troubleshooting HP 8514B and 8512A Test Sets User4 log MAG REF 51 45 dB 1 10 0 dg 24 813 dB START 9 045000000 GHz STOP 20 000000000 GHz Figure 5 20 Typical HP 8514B Option 002 003 b2 Reflection Trace 91 VTO SENSE PRETUNE TUNE OPEN OR SHORT Figure 5 21 8514B Option 002 003 b2 Reflection Signal Path HP 8514B and 8512A Test Sets Test Set Troubleshooting 5 33 START 945000000 GHz STOP 20 090002000 GHz Figure 5 22 Typical HP 8514B Option 002 003 b1 Thru Trace VTO SENSE PRETUNE 01 TUNE a L FRET Figure 5 23 8514B Option 002 003 b1 Thru Signal Path 5 34 Test Set Troubleshooting HP 8514B and 8512A Test Sets START 0 0450000020 GHz sToP 20 000000000 GHz Figure 5 24 Typical HP 8514B Option 002 003 b2 Thru Trace VTO SENSE PRETUNE Figure 5 25 8514B Option 002 003 b2 Thru Signal Path HP 8514B and 8512A Test Sets TUNE Test Set Troubleshooting 5 35 If Any User Channel Looks Bad Equipment SOURCE Figure 5 26 One or more user channels appear faulty The question is what is at fault the source or test set or IF detector HP 85102 The service adapter is a source test set emulator It pro
25. are precision 3 5 mm male connectors and mate with precision 3 5 mm female connectors The HP 8512A has 7 mm test port connectors The TEST SET INTERCONNECT connector is a series D subminiature female connector with 7 RF connections The 8510 SYSTEM BUS connector is a female HPIB type connector and mates with the corresponding male connectors of HPIB cables Power and Control Connections Figure 2 3 shows the following connections with the exception of line power and the required RF source connections Connect the power cord to an electrical outlet and the line module to supply power to the test set Connect the test set IF interconnect cable from the J11 TEST SET INTERCONNECT connector on the rear panel of the test set to the JI TEST SET INTERCONNECT connector on the rear panel of the HP 85102 IF Detector Connect the system bus cable from the HP 8514B or 8512A J12 8510 SYSTEM BUS connector to the 8510 INTERCONNECT connector of the HP 85101 display processor The test set IF interconnect cable and the Installation 2 5 Packaging 2 6 Installation system bus cable transmit control signals between the test set and the network analyzer Signal Path Connections The IF signals from the test set are transmitted to the HP 85102 IF detector by the test set IF interconnect cable see above RF signals are transmitted from the source to the test set by the 3 5 mm flexible RF cable supplied with the test set Recommended tor
26. between the test sets Repeat for each of the test sets Any difference in the data believed due to the option 001 IF switch or RF switching must be investigated Standard System Performance Verification procedures are used to verify the operation of the option 001 test set as test set number 1 To verify the performance of another test set in the chain select it as the active test set and proceed as usual Operation 3 13 HP11713A B A 24V B HP33311C HP33311C HP33311C COAXIAL COAXIAL COAXIAL SWITCH SWITCH 2 me 2 RF IN FROM SOURCE TEST SET 1 TEST SET 2 TEST SET 3 TEST SET 4 TO HP85108 NETWORK ANALYZER TEST SET INTERCONNECT HP851X 001 51 001 51 001 HP851X TEST SET 1 TEST SET 2 TEST SET 3 TEST SET 4 TEST SET REAR PANEL TEST SET REAR PANEL TEST SET REAR PANEL TEST SET REAR PANEL ADDRESS SWITCH SET ADDRESS SWITCH SET ADDRESS SWITCH SET ADDRESS SWITCH SET To 21 TO 21 TO 22 TO 23 NOTE 1 Not all system connections are shown 2 In dual source configurations the second can be multiplexed in a similar manner If only one dual source test set is used the second source can be directly connected to the appropriate test set Figure 3 6 and IF Switching with Four Test Sets HP 33311C Coaxial Switch Positions with Four Test Sets HP 33311C Coaxial Switch New ADDRESS of Test Set Port Selected Test Set Selected Switch 1 Switch 2 20
27. manual set are a more rigorous check Volume 2 of the HP 8510A manual set documents the HP 8512A only Also included in this section adescription of the Multiple Test Set Option Option 001 instructions for connecting a cable and anti rotation clamp to your test set test port HP 8514B and 8512A Test Sets Operation 3 1 Front Panel Features Figure 3 1 Front Panel Features of HP 8514B upper and HP 8512A 1 Line Switch This switch turns the test set on and off When the side of the switch labeled O is depressed the test set is off is on 2 Line LED This LED goes on and off with the test set line switch 3 Active LED This LED lights about two seconds after power is turned on following the successful conclusion of self test 3 2 Operation HP 8514B and 8512A Test Sets HP 8514B and 8512A Test Sets Port 1 This test port transmits RF energy from the source to the DUT and receives reflected RF energy from the DUT The reflected RF energy is coupled to a sampler within the instrument Bias Fuse HP 8514B only The fuse which limits bias applied to Port 1 is within this holder see the instrument front panel or the replaceable parts list for the value of the fuse F1 al LED HP 8514B only This LED indicates that the HP 8514B is internally switched to the S11 or S21 mode and source power is switched to Port 1 a2 LE HP 8514B only This LED indicates that the HP 8514B is internal
28. message is only a prompt It does not turn off the test set Determine the reason for the prompt before again subjecting the test set to continuous use Make sure the fan is operating properly and is not covered by a piece of paper etc Make sure the fan and the side panel air exhaust has at least 8 cm about 3 inches clearance and top cover exhaust has at least 1 5 cm about 0 5 inches clearance Check All Connections loose broken crimped etc 5 2 Test Set Troubleshooting Power holes power loss at a specific frequency often result from faulty connections Check the following connections Test set rear panel including the extension links Cables connected to the summing amplifier and 5 Attenuator S witch Sampler cables RF path connections from rear panel to front panel HP 8514B and 8512A Test Sets Check Power Supply Regulator Fuses and Switches A15 Regulator Board Assembly Use a digital voltmeter to check the voltages given in Table 5 1 Use an oscilloscope to check AC ripple Use chassis ground as reference Table 5 1 Test Set Power Supply Tolerannces Nominal Maximum Ripple Voltage Test Point Voltage Range Peak to Peak 15 V A15TP1 13 7 to 15 9 V 2 mV 15 V A15TP2 13 8 to 16 2 V 2mV 5 A15TP3 4 5 to 5 2 V 2 5 A15TP6 4 8 to 5 5 V 2mV Fuses Fuses for the regulator board assembly rear panel and front panel are specified in the parts lis
29. narrow band systems the level of the frequency band generated should match the levels shown in Figure 3 3 for a given frequency Now perform either the HP 8514B or 8512A Operator s Check In case of difficulty refer to Test Set Troubleshooting in the HP 85 0B Service Manual or contact your local HP Service Office HP 8514B and 8512A Test Sets HP 8514B Operator s Check NOTE All of the following HP 8514B CRT traces should decrease from 20 5 dB at 2 GHz to 27 5 dB at 20 GHz Sampler Test 1 check all of the samplers in the HP 8514B test set first redefine the a2 and b2 phaselock and drive paths Press PARAMETER MENU User 3 a2 REDEFINE PARAMETER DRIVE Port 2 PHASE LOCK a2 REDEFINE DONE to redefine a2 Press User 2 b2 REDEFINE PARAMETER DRIVE Port 2 PHASE LOCK a2 REDEFINE DONE to redefine b2 2 Connect an open or short to port 1 and port 2 3 Press User 1 a1 User 2 b2 User 3 a2 and User 4 b1 to check the channels indicated The b1 and b2 traces should resemble Figure 3 3 The al and a2 traces should resemble Figure 3 4 User2 tog MAG REF 0 0 1 10 0 d8 19 222 START 245888002 GHz STOP 206 000000000 GHz Figure 3 3 Typical Operator s Check CRT Power Level Trace b1 Thru Test 4 Connecta thru two test port return cables from port 1 to port 2 5 Press PARAMETER MENU User 4 b1 REDEFINE PARAMETER
30. or bad connection in the RF path at that location Hardline Cabie Test Port Power Hardline Cable Extension Splitter Wh iy d WAAL at Figure 5 4 8512A Typical Port 1 Response Switch Splitter Programmab Attenuator Figure 5 5 HP 8514 Typical Port 1 and Port 2 Response 5 8 Test Set Troubleshooting HP 8514B and 8512A Test Sets Test Set Assembly Replacement Procedures This section describes how to replace HP 8510 test set major assemblies and components The HP 8510 test sets include the HP 8512A 8514A and 8514B This procedure does not explain how to remove 7 mm connectors If your test set has 7 mm connectors refer to the test set manual for removal instructions Not all of the procedures apply to all of the test sets Nor do all of the test sets contain all of the parts documented in the following text and figures Use them as applicable The procedures appear in this order 2 Un 9 N m rn c 13 Bias tee Coupler Switch splitter Frequency converter Sampler VTO assembly Regulator board assembly Step attenuator assembly Capacitor 3 5 mm RF connectors Fan Port 1 and 2 3 5 mm connectors Power transformer Before beginning any of the following procedures HP 8514B and 8512A Test Sets Turn the test set OFF Remove the top cover
31. port 2 6 Press PARAMETER MENU USER 4 b1 REDEFINE PARAMETER DRIVE PORT 2 PHASELOCK a2 REDEFINE DONE to observe the b1 power level trace through the path indicated by Figure 5 12 through Figure 5 25 61 thru Press Parameter MENU USER 2 b2 REDEFINE PARAMETER DRIVE PORT 1 PHASELOCK a1 REDEFINE DONE to observe the b2 power level trace through the path indicated by Figure 5 12 through Figure 5 25 Test Set Troubleshooting 5 25 Next Step If one or more channels look abnormal refer to the procedure titled If Any User Channel Looks Bad on page 5 36 5 26 Test Set Troubleshooting HP 8514B and 8512A Test Sets 0 500000000 Giz sToP 18 000000000 Griz HP 8512A ai and b2 thru trace START 0 0450900000 GHz STOP 20 000000000 GHz HP 85148 bi reflection and b2 reflection trace Figure 5 11 Typical Test Set Unratioed Power Test Traces HP 8514B and 8512A Test Sets Test Set Troubleshooting 5 27 VTO SENSE PRETUNE VTO SENSE PRETUNE BIAS 2 w 2 e m 50 HARMONIC HARMONIC 59 62 BIAS 1 TUNE RF IN a2 BIAS 2 BIAS 1 b1 e al b2 91 92 5T A b2 BIAS 1 ere at PRETUNE TUNE IE RF IN a2 BIAS 2 BIAS VTO SENSE PRETUNE TUNE RF IN b2 BIAS 2 ri EXT A b2 92 Wi EXT A VTO SENSE a ee A PORT 1 OPEN OR SHORT OPEN OR SHORT b Refl
32. so hold the RF cable throughout the rest of this procedure Do not allow the cable to rotate NOTE 2 Turn the clamp so that the thumbscrew is pointing up From there turn the clamp to visually align the clamp flats with the flats on the test port connector nut This will minimize rotating the connector in the next step Refer to Figure 3 7 The flats may be in any orientation in respect to the front panel HP 8514B and 8512A Test Sets Operation 3 15 MAKE SURE FLAT SURFACE ON REAR OF CABLE CLAMP IS PARALLEL WITH FLAT SURFACE OF TEST SET CONNECTOR FRONT VIEW OF FRONT VIEW OF TEST SET CONNECTOR CABLE CLAMP Figure 3 7 Visually Aligning Clamp Nut Flats 3 Make sure that you do not twist the cable as you attach it to the test port Use the torque wrench supplied with your calibration kit to tighten the cable to no more than 90 N cm 8 in Ib 4 Hold the cable with one hand and with the other press the clamp gently and steadily while wiggling the clamp straight over the RF connector and onto the test port connector nut The internal flats in the clamp must fit over the flats on the test port connector nut Try not to rotate the clamp as you do this or the RF connection may be loosened Refer to Figure 3 8 HOLD CABLE HERE WITH ONE HAND FACE OF TEST SET PRESS CLAMP HERE GENTLY STEADILY PART OF TEST SET CONNECTOR Figure 3 8 Mating the Clamp and Nut Flats 3 16 Operation HP 8514B and 8512A T
33. 0025 1 COVER SIDE PERF 84 0380 0010 4 SPACER RND 625 IN LG 18 IN ID 85 3050 0105 3 WASHER FL MTLC NO 4 125 IN ID 86 2360 0127 1 SCREW MACH 6 32 875 IN LG PAN HD POZI 87 08513 00017 CONV ASSEY HP 8514B and 8512A Test Sets Replaceable Parts 6 29 20 QAI hidden A18 on i 03 C2 A6 AD AM Afi Figure 6 13 HP 8512A Top View Showing Locations of Major Assemblies 6 30 Replaceable Parts HP 8514B and 8512A Test Sets 2 PLACES G J13 55 14 P O A6 is ia See Y pod Figure 9 See Figure 9 8 PLACES 8 PLACES 87 NOT SHOWN 4 PLACES 4 PLACES 5 PLACES 4 J10 o 99 9 3 PLACES E 0 J3 E25 E21 J4 E26 E22 J5 E27 Q Eig J2 gl N x GEM e X 2 A20 4 PLACES NE 4 4 PLACES 27057 NOTE Some line modules 45 PLACES may different Figure 6 14 HP 8512A Miscellaneous Mechanical Chassis and Electrical Parts Replaceable Parts 6 31 HP 8514B and 8512A Test Sets LEFT SIDE 6 places 16 places Not Shown RIGHT SIDE Py eS We Ee BRO LEE EHH S amp H Figure 6 15 8512A Miscellaneous Mechanical Chassis and Electrical Parts 6 32 Replaceable Parts HP 8514 8512A Test Sets 37 places Not Visible Figure 6 16 8512A Miscellaneous Mechanical Chassis and Electrical Parts HP 8514
34. 1 Remove the damaged nut withh a 9 16 inch flat wrench 2 Replace with a new nut 3 Torque with a 9 16 inch torque wrench to the limits set in Figure 5 8 13 Power Transformer WARNING Turn the test set OFF and disconnect the power cord from the mains Electrocution can result if power is not removed from the test set prior to this procedure 1 Turn the test set on its right hand side 2 Use 5 16 inch open end wrench to remove the hardline cable connected between coupler A7 and bulkhead connector J2 3 Unplug the transformer connector mating with connector J2 on the 15 regulator board assembly 4 Usea large pozi driv screwdriver to remove the four screws and washers holding transformer T1 onto the rear panel 5 Use a large pozi driv screwdriver to remove the one screw holding the transformer angle bracket to the main deck Carefully remove the transformer from the test set and put it on the bench close to the test set The transformer wires soldered to line module FL 1 are short so do not pull on the transformer too much 6 Strip the heat shrink tubing off of the transformer wires soldered to line module FL1 and unsolder them Unsolder the transformer ground wire connected to the chassis side rail HP 8514B and 8512A Test Sets Test Set Troubleshooting 5 21 Remove transformer T1 When replacing the transformer refer to Figure 5 9 which illustrates the locations of the various wires connected to line module F
35. 1 0360 0009 1 TERMINAL SLDR LUG PL MTG FOR SCR E2 0360 0031 2 TERMINAL CRIMP R TNG 6 22 16 AWG RED E3 0360 0031 TERMINAL CRIMP R TNG 6 22 16 AWG RED E4 0362 0265 2 CONNECTOR SGL CONT SKT 1 14 MM BSC SZ E5 0362 0265 CONNECTOR SGL CONT SKT 1 14 MM BSC SZ E6 08513 00018 1 INSULATOR BRACE E7 0360 1673 1 TERMINAL STRIP 6 TERM PHEN 1 5 IN L E8 5021 3510 5 CONTACT FEMALE E9 5021 3510 CONTACT FEMALE E10 5021 3510 CONTACT FEMALE E11 5021 3510 CONTACT FEMALE E12 5021 3510 CONTACT FEMALE E13 5061 5301 5 3 5MM BEAD R AY E14 5061 5301 3 5MM BEAD R AY E15 5061 5301 3 5MM BEAD R AY E16 5061 5301 3 5MM BEAD R AY E17 5061 5301 3 5MM BEAD R AY E18 08513 20016 5 CONNECTOR NOSE F E19 08513 20016 CONNECTOR NOSE F E20 08513 20016 CONNECTOR NOSE F E21 08513 20016 CONNECTOR NOSE F E22 08513 20016 CONNECTOR NOSE F E23 08513 20017 5 CONN BULKHEAD E24 08513 20017 CONN BULKHEAD HP 8514B and 8512A Test Sets Replaceable Parts 6 5 Table 6 1 8514B Replaceable Parts Continued HP Part Number Qty Description E25 08513 20017 CONN BULKHEAD E26 08513 20017 CONN BULKHEAD E27 08513 20017 CONN BULKHEAD E28 08513 20018 5 CENTER CNDCT BHD E29 08513 20018 CENTER CNDCT BHD E30 08513 20018 CENTER CNDCT BHD E31 08513 20018 CENTER CNDCT SHO E32 08513 20018 CENTER CNOCT BHD E33 2110 0797 2 FUSEHOLDER E34 2110 0797 FUSEHOLDER E35 85050 20001 2 CONTACT CTR COND E36 85050 20001 CONTACT CTR COND E37 2110 0565 2 FUSEHOLDER CA
36. 1 7882 CONNECTOR PC EDGE 2 ROWS A20 08513 60006 1 BOARD ASSEMBLY HPIB INTERCONNECT MISCELLANEOUS ELECTRICAL PARTS B1 3160 0273 1 FAN TBAX 34 CFM 115V 50 60 HZ 1 5KV DIEL E1 0360 0009 1 TERMINAL SLDR LUG PL MTG FOR 6 SCR E2 0360 0031 2 TERMINAL CRIMP R TNG 6 22 16 AWG RED E3 0360 0031 TERMINAL CRIMP R TNG 6 22 16 AWG RED E4 0362 0265 2 CONNECTOR SGL CONT SKT 1 14 MM BSC SZ E5 0362 0265 CONNECTOR SGL CONT SKT 1 14 MM BSC SZ E6 08513 00018 1 INSULATOR BRACE E7 1250 0816 2 CONTACT RF CONN CONTACT ASSY E8 1250 0816 CONTACT RF CONN CONTACT ASSY E9 1531 0278 1 MACHINED PART SST OUTER FLANGE COUPLER E10 5021 3510 5 CONTACT FEMALE E11 5021 3510 CONTACT FEMALE E12 5021 3510 CONTACT FEMALE E13 5021 3510 CONTACT FEMALE E14 5021 3510 CONTACT FEMALE E15 5040 0306 2 INSULATOR E16 5040 0306 INSULATOR E17 08512 20001 1 CTR BDY PNL CONN E18 08512 20002 1 INR CNDCT PNL E19 08513 20016 5 CONNECTOR NOSE F E20 08513 20016 CONNECTOR NOSE F E21 08513 20016 CONNECTOR NOSE F E22 08513 20016 CONNECTOR NOSE F E23 08513 20016 CONNECTOR NOSE F E24 08513 20017 5 CONN BULKHEAD E25 08513 20017 CONN BULKHEAD E26 08513 20017 CONN BULKHEAD E27 08513 20017 CONN BULKHEAD E28 08513 20017 CONN BULKHEAD E29 08513 20018 5 CENTER CNDCT BHD E30 08513 20018 CENTER CNDCT BHD E31 08513 20018 CENTER CNDCT BHD HP 8514B and 8512A Test Sets Replaceable Parts 6 25 Table 6 2 8512A Replaceable Parts Continued Pa
37. 1 Port 1 Port 1 21 2 Port 1 Port 2 22 3 Port 2 Port 1 23 4 Port 2 Port 2 3 14 Operation HP 8514B and 8512A Test Sets Cable and Anti Rotation Clamp Installation Procedure NOTE The HP 08515 60003 Anti Rotation Clamps are used to secure the RF connections at the test ports of several Hewlett Packard test sets When installed each clamp holds the large nut that secures the test set RF port connector to the front panel and the RF cable connector or the front panel adapter mated with the port connector Without the clamps the test port connections may become loose after moving the connected device and could invalidate calibrations and measurements Although the anti rotation clamps may be used with front panel adapters these instructions refer to an installation using the HP RF Cables Adapter installations will be similar NOTE 1 Two anti rotation clamps are included in the test set accessories box Remove one from the box and loosen the thumbscrew until it is almost out of the counter bored hole in the clamp body Gently push the clamp round hole end first over and past the RF cable connector you will connect to the test set RF port The rubber O ring in the round end of the clamp will fit tightly over the connector Wiggle the clamp if necessary to get it over the connector Connect the cable to the test port and tighten as specified in the cable manual The test set RF connector is easily loosened
38. 2 6 6 Replaceable Parts HP 8514B and 8512A Test Sets Table 6 1 8514B Replaceable Parts Continued HP Part Number Qty Description W27 08513 60147 1 AY A11J3 J11A3 W28 NOT ASSIGNED W29 NOT ASSIGNED W30 NOT ASSIGNED W31 08514 20028 1 CA RF A8J3 A11J2 W32 08514 20027 1 CA RF A6J3 A10J2 W33 08514 20013 2 CA RF J2 J3 W34 08514 20014 2 A18J1J3 W35 08514 20015 1 CA RF A18J7 A17J2 W36 08514 20016 1 CA RF A7J1 A16J1 W37 08514 20017 1 CA RF A18J8 A16J2 W38 08514 20018 1 CA RF A9J1 A17J1 W39 08514 20019 1 CA RF A18J5 J7 W40 08514 20026 1 CA RF A13J2 J2 W41 08514 20025 1 CA RF A12J2 J5 W42 NOT ASSIGNED W43 08514 20013 CA RF J4 J5 W44 08514 20014 A18J2J4 W45 W49 SEE Figure 6 11 W50 W56 NOT ASSIGNED W57 08513 60014 1 CBL AY RP MB W58 08513 60036 1 CBL AY RP HPIB W59 85102 60226 1 CA ASSY LINE SW W60 08513 60013 1 CA AY FRPNL MBD W61 08510 60102 1 CBL AY TEST SET W62 8120 1348 1 CABLE ASSY 18AWG 3 CNDCT BLK JKT W63 8120 3445 1 HP IB CABLE 1 METER W64 8120 4396 1 CBL C AY SMA w65 08514 20001 1 CA RF A9J1 A18J7 W66 08514 20002 1 CA RF A7J1 A18J8 W67 08512 20019 2 CA AY J2J3 amp J4J5 W68 08512 20019 CA J2J3 amp J4J5 MISCELLANEOUS MECHANICAL amp CHASSIS PARTS 1 0380 0643 2 STANDOFF HEX 255 IN LG 6 32THD 2 0400 0002 4 GROMMET RND 188 IN ID 312 IN GRV OD 3 0590 0926 4 THREADED INSERT STDF 6 32 188 IN LG SST 4 1251 2942 4 LOCK SUBMIN D CONN 5 2360 0113
39. 44 E12 W39 E10 W34 EIT w35 65 68 55 E1 4 7 places 8 Gy W38 63 32 wat w40 w32 33 w31 Not Visible Figure 6 6 HP 8514B Miscellaneous Mechanical Chassis and Electrical Parts HP 8514B and 8512A Test Sets Replaceable Parts 6 15 A19 Fra LJ LJ 10 _ Figure 6 7 8514B and HP 8512A Motherboard Component Location Diagram 6 16 Replaceable Parts HP 8514B and 8512A Test Sets Figure 6 8 Parts Unique to HP 8514B and 8512A Option 001 HP 8514B and 8512A Test Sets Replaceable Parts 6 17 HP 8514B and 8512A Test Sets 6 18 Replaceable Parts Reference Designation HP Part Number Qty Description A2 08513 60004 1 IF MULTIPLEXER BD AY NEW A2 08513 69004 IF MULTIPLEXER BD AY REBUILT w1 08513 60121 1 A12J3 A2J1 CABLE AY W2 08513 60122 1 A13J3 A2J7 CABLE AY W3 08513 60123 1 A10J3 A2J4 CABLE AY WA 08513 60124 1 A11J3 A2J10 CABLE AY W5 08513 60125 1 A2J2 J11A1 CABLE AY W6 08513 60126 1 A2J8 J11A4 CABLE AY W7 08513 60127 1 A2J5 J11A2 CABLE AY W8 08513 60128 1 A2J11 J11A3 CABLE AY W9 08613 60129 1 A2J3 J10A1 CABLE AY W10 08513 60130 1 A2J9 J10A4 CABLE AY W11 08513 60131 1 A2J6 J10A2 CABLE AY W12 08513 60132 1 A2J12 J10A3 CABLE AY W13 SEE Table 6 1 W14 SEE Table 6 1 W15 08513 60135 1 A3J3 J10A7 CABLE AY W16 SEE Table 6 1 W17 08513 60137 1 A3J6 J10A5 CABLE AY W18 SEE Table 6 1 W19 08513 60139 1 A3J8 J10A6 CABLE AY HP 8514B and 8512A Test Sets Replace
40. 700 Northern California Hewlett Packard Company 301 E Evelyn Mountain View CA 94041 415 694 2000 Colorado Hewlett Packard Company 24 Inverness Place East Englewood CO 80112 303 649 5000 Georgia Hewlett Packard Company 2000 South Park Place Atlanta GA 30339 404 9554 1500 Illinois Hewlett Packard Company 5201 Tollview Drive Rolling Meadows IL 60008 708 342 2000 New Jersey Hewlett Packard Company West 120 Century Road Paramus NJ 07653 201 599 5000 Texas Hewlett Packard Company 930 E Campbell Road Richardson TX 75081 214 231 6101 vi Any adjustment maintenance or repair of this product must be performed by qualified personnel contact your local HP sales and service office European Operations Headquarters Hewlett Packard S A 150 route du Nant d Avril 1217 Meyrin 2 Geneva Switzerland 41 22 780 8111 France Hewlett Packard France 1 avenue du Canada Zone d Activite de Courtaboeuf F 91947 Les Ulis Cedex France 33 1 69 82 60 60 Germany Hewlett Packard GmbH Hewlett Packard Strasse 61352 Bad Homburg Germany 49 6172 16 0 Great Britain Hewlett Packard Ltd Eskdale Road Winnersh Triangle Wokingham Berkshire RG11 5DZ England 44 734 696622 Intercon Operations Headquarters Hewlett Packard Company 3495 Deer Creek Road Palo Alto CA 94304 1316 USA 415 857 5027 Australia Hewlett Packard Australia Ltd 31 41 Joseph Street Post Office Box 221
41. 713R RTTENURTOR SHITCH DRIVER na om aono n a HP8510B SYSTEM BUS D HP33311C COAXIAL SWITCH 1 OR HP8350B SOURCE TEST SET INTERCONNECT HP851X 001 HP851X TEST SET 1 TEST SET 42 TEST SET REAR PANEL TEST SET REAR PANEL ADDRESS SWITCH SET ADDRESS SWITCH SET TO 20 TO 21 NOTE 1 Not all system connections are shown 2 In dual source configurations the second can be multiplexed in a similar manner If only one dual source test set is used the second source can be directly connected to the appropriate test set HP 8514B and 8512A Test Sets Operation 3 11 Figure 3 5 RF and IF Switching with Two Test Sets HP 33311C Coaxial Switch Positions with Two Test Sets New ADDRESS Test Set HP 33311C Coaxial Switch of Test Set Selected Port Selected 20 1 Port 1 21 2 Port 2 Selecting a Test Set Test Set IF Switching The active test set is selected by the built in capability of the HP 8510 to generate an addressed command to the test set Each time the HP 8510 ADDRESS of TEST SET function is changed see HP 8510 LOCAL menu the HP 8510 switches the previously addressed test set IF to external and the newly addressed test set IF to internal The test set front panel ACTIVE indicator shows the test set status When the test set is active the IF signals from the test set are applied directly to
42. 82 DEG 46 1400 1209 1 CLP CA 69D 1 0W 47 2190 0104 5 WASHER LK INTL T 7 16 IN 439 IN ID 48 2200 0109 1 SCREW MACH 4 40 438 IN LG PAN HD POZI 49 2360 0121 2 SCREW MACH 6 32 5 IN LG PAN HD POZI 50 2510 0141 4 SCREW MACH 8 32 562 IN LG PAN HD POZI 51 2950 0132 5 NUT HEX DBL CHAM 7 16 28 THD 094 IN THK 52 6960 0001 2 PLUG HOLE DOME HD FOR 375 D HOLE STL 53 7121 2380 1 LABEL SERIAL NUMBER 54 5021 0906 6 SLEEV RF PIN POS 55 5021 3427 2 WSHR TS PORT CON 56 5021 3438 2 NUT FLG TS PORT 57 08512 00001 1 FRONT PANEL 58 08512 00008 2 CLAMP A 59 08512 00009 1 CLAMP B 60 08512 00010 2 CLAMP C 61 08512 00011 1 CLAMP D 62 08513 00017 2 BRACKET CONV AY 63 08513 00019 1 COVER I F MUX 64 08513 00027 1 CVR BLANK IF MUX 65 08514 00002 1 SUB PANEL 66 08514 20005 1 BLOCK MTG CPLR 67 NOT ASSIGNED 68 85102 00041 1 COVER BLANK A16 69 2510 0195 6 SCREW MACH 8 32 375 IN LG 100 DEG 70 7120 4835 1 LABEL INFORMATION 75 IN WD 2 IN LG PPR 71 7120 5911 1 LABEL WARNING 1 IN WD 7 IN LG PPR 72 74 NOT ASSIGNED 75 5020 8896 2 TRIM FRNT HNDL 76 5040 7201 4 FOOT BOTTOM 77 5040 7202 1 STRIP TRIM TOP 78 5040 7221 4 FOOT REAR 79 5060 9847 1 COVER BTM 18 FM 80 5060 9857 1 COVER AY SIDE 6 28 Replaceable Parts HP 8514B and 8512A Test Sets Table 6 2 8512A Replaceable Parts Continued HP Part Number Qty Description 81 5060 9899 2 HANDLE AY FRONT 82 08513 00021 1 TEST SET CVR TOP 83 08513 0
43. 9C4 0180 2671 CAPACfTOR FXD 012F 75 10 30VDC AL A19C5 0160 4834 CAPACITOR FXD 047UF 10 100VDC CER A19C6 0160 4834 CAPACITOR FXD 047UF 10 100VDC CER A19J1 1251 5745 CONNECTOR 20 PIN M POST TYPE A19J1 DOES NOT INCLUDE 19 1 amp A19MP2 A19J2 1251 6868 4 CONNECTOR 5 PIN M POST TYPE A19J3 1251 7939 1 CONN POST TYPE 100 PIN SPCG 14 CONT A19J3 DOES NOT INCLUDE A19MP3 A19J4 1251 6868 CONNECTOR 5 PIN M POST TYPE A19J5 1251 6868 CONNECTOR 5 PIN M POST TYPE A19J6 1251 6868 CONNECTOR 5 PIN M POST TYPE A19J7 1251 3825 1 CONNECTOR 5 PIN M POST TYPE A19J8 1200 0508 2 SOCKET IC 14 CONT DIP SLDR A19J9 1200 0508 SOCKET IC 14 CONT DIP SLDR A19MP1 1251 5595 POLARIZING KEY POST CONN A19MP2 1251 5595 POLARIZING KEY POST CONN A19MP3 1251 5595 POLARIZING KEY POST CONN 6 24 Replaceable Parts HP 8514B and 8512A Test Sets Table 6 2 HP 8512A Replaceable Parts Continued Part Number Qty Description A19R1 0764 0015 2 RESISTOR 560 5 2W MO 0 200 A19R2 0764 0015 RESISTOR 560 5 2W MO 0 200 A19R3 0764 0016 2 RESISTOR 1K 5 2W MO TC 0 200 AI9RA 0764 0016 RESISTOR 1K 5 2W MO TC 0 200 A19R5 0757 0394 RESISTOR 51 1 1 125W TC 0 100 A19R6 0757 0394 RESISTOR 51 1 1 125W TC 0 100 A19XA2 1251 7882 5 CONNECTOR PC EDGE 2 ROWS A19XA3 1251 7882 CONNECTOR PC EDGE 2 ROWS A19XA4 1251 7882 CONNECTOR PC EDGE 2 ROWS A19XA5 1251 7882 CONNECTOR PC EDGE 2 ROWS A19XA6 NOT ASSIGNED A19XA14 A19XA15 125
44. AMETER MENU USER 2 b2 REDEFINE PARAMETER DRIVE PORT 1 PHASELOCK a1 REDEFINE DONE to observe the b2 power level trace The trace should resemble Figure 3 4 6 If any of the traces are not within the specified limits check all of the connections and repeat the above procedure If symptoms persist refer to the Service Overview section of the HP 8510 Service Manual or volume 4 of the HP 8510A manual set Operation 3 9 Controlling Multiple Test Sets Installation Operation 3 10 Operation Option 001 for the HP 851X series test sets allows an HP 8510 to alternately control up to four test sets While a measurement is proceeding on Test Set number 1 which is equipped with option 001 test device hookup be accomplished on Test Set number 2 which does not need to be equipped with option 001 unless another test set is to be connected When the measurement test set number 1 is complete then the HP 8510 can control test set number 2 Only one HP 85164 test set may be used in a multiple test set configuration In a standard test set the 20 MHz IF and control signals are applied directly to TEST SET INTERCONNECT which connects to the HP 8510 Option 001 adds a set of IF switches control switches and the J10 TEST SET INTERCONNECT connector This allows the selection of 20 MHz test set IF signals As shown in Figure 3 5 test set number 1 can apply its IF to the HP 8510 or it can switch to pass the I
45. Bad 5 35 Equipment ze ensi eg te s 5 35 Service Adapter Conclusions 5 36 HP 8514B and 8512A Test Sets Contents 3 6 Replaceable Parts Introduction Rs 6 1 Exchange Assemblies Available 6 2 Replaceable Parts 15 6 6 3 7 Service 8 Miscellaneous Performance Tests uda ve Ce ELDER ES 8 1 Adjustinents ald 8 1 Manual 8 1 Contents 4 HP 8514B and 8512A Test Sets General Information Introduction The purpose of this manual is to enable you to use your HP 8514B S parameter or HP 8512A reflection transmission test set effectively and confidently These test sets are integral components of the HP 8510 measurement system For that reason this manual has been divided into two major portions Operating and Service to be an integral part of the HP 8510 documentation General information Installation Operation Specifications The Service part consists of Test set troubleshooting Replaceable parts Service Miscellaneous including o Performance tests o Adjustments o M Backdating The major topics of this section General Information are HP 8514B and 8512A Test Sets how to use the test set what the test set is operating
46. ENCL 33 08513 60156 2 ENCLOSURE CKT 34 08512 20005 1 RFI GASKET 35 08513 00001 1 DECK 36 08513 00002 1 TRANSFORMER BRKT 37 08513 00005 1 MTG BRACKET LH 38 08513 00006 1 MTG BRACKET RH 39 08513 00015 1 CAP SPRT PLATE 40 08513 00037 1 BRACKET CKT ENCL 41 08513 20013 1 BRACE DECK 42 08513 20015 1 MOUNTING BAR 43 5021 8747 1 FRONT BEZEL MACH 44 0460 0100 1 TAPE INDL 1 IN W 002 IN T ACRLC XFR ADH 45 0520 0174 1 SCREW MACH 2 56 25 IN LG PAN HD POZI 46 0624 0589 8 SCREW TPG 4 40 25 IN LG UNCT 82 DEG 47 1400 1209 1 CLP CA 69D 1 0W 48 1450 0615 2 RETAINER LED 0 75 IN LG 0 38 IN WD 49 NOT ASSIGNED 50 2110 0569 2 FUSEHOLDER COMPONENT NUT THREAD M12 7 51 2190 0016 2 WASHER LK INTL T 3 8 IN 377 IN ID 52 2190 0104 5 WASHER LK INTL T 7 16 IN 439 IN ID 53 2200 0109 2 SCREW MACH 4 40 438 IN LG PAN HD POZI 54 2200 0164 4 SCREW MACH 4 40 188 IN LG UNCT 82 DEG 55 2260 0009 8 NUT HEX W LKWR 4 40 THD 094 IN THK 56 2360 0121 1 SCREW MACH 6 32 5 IN LG PAN HD POZI 57 2510 0043 4 SCREW MACH 8 32 312 IN LG PAN HD POZI 58 2510 0141 4 SCREW MACH 8 32 562 IN LG PAN HD POZI 59 2950 0001 2 NUT HEX DBL CHAM 3 8 32 THD 094 IN THK 60 2950 0132 5 NUT HEX DBL CHAM 7 16 28 THD 094 IN THK 61 7121 2380 1 LABEL SERIAL NUMBER 6 8 Replaceable Parts HP 8514B and 8512A Test Sets Table 6 1 8514B Replaceable Parts Continued HP Part Number Qty Description 62 5021 0906 7 SLEEV RF PIN POS 63 5021 3427 2 WSHR
47. F from test set number 2 through the J10 TEST SET INTERCONNECT to the HP 8510 Set each test set rear panel address switch to the address listed in Figure 3 5 if using a two test set configuration and Figure 3 6 if configuring more than two test sets Use the supplied Test Set Interconnect cable to connect test set number 1 J11 to the HP 8510 Use the supplied Test Set Interconnect cable to connect test set number 2 J11 to test set number 1 J10 You may continue this test set daisy chain to include up to four test sets if the total length of all Test Set Interconnect cables does not exceed 13 meters about 40 feet The last test set in the chain does not require option 001 If the RF coaxial switch s is not incorporated into the system then the RF input to the test set must be manually switched to the active test set Initialization at Power up Upon power up the IF switches must be configured so that only one system test set is active The following procedure shows how to make one test set active 1 Check the active lights of all system test sets 2 Check the HP 8510 s expected test set address by pressing LOCAL TEST SET This should match the address of the desired test set If not change the address HP 8514B and 8512A Test Sets 3 If unselected test sets are active active light ON deactivate the test set by temporarily addressing it Then return to the desired address HP 85108 NETHORK ANALYZER HP 11
48. ISPR 11 1990 EN 55011 1991 Group 1 Class A IEC 801 2 1991 EN 50082 1 1992 4 kV CD 8 kV AD IEC 801 3 1984 EN 50082 1 1992 3 V m 27 500 MHz IEC 801 4 1988 EN 50082 1 1992 500 V signal 1000 V AC Supplementary Information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC The HP 8514B was qualified as part of a product family which includes the HP 8510C HP 85304A HP 8511A HP 8511B HP 8515A HP 8516A HP 8517A HP 85105A HP 85110A and HP 85309A Santa Rosa Californi anta Rosa 2 SPI Location Dixon Browder Quality Manager European Contact Your local Hewlett Packard Sales and Service Office or Hewlett Packard GmbH Department ZQ Standards Europe Herrenberger Strafe 130 D 7030 B blingen FAX 49 7031 143143 Notice for Germany Noise Declaration LpA lt 70 dB am Arbeitsplatz operator position normaler Betrieb normal position nach DIN 45635 T 19 per ISO 7779 x HP 8514B and 8512A Test Sets Contents e eoe ed ae aah ii Restricted Rights Legend il Serial N mbets SAR TALE TR RC US T il What You ll Find in This Manual iii Section I HP 8514B or 8512A Test Set Information iii Section II HP 8514B or 8512A Troubleshooting Information iii
49. J2 W33 08512 20006 1 CA A12J2 J4 W34 08513 20020 1 CA RF A18J3 PRT 1 W35 08513 20021 1 CA RF A18J2 PRT 2 W36 08513 20022 1 CA AY A18J1 RF 6 26 Replaceable Parts HP 8514B and 8512A Test Sets Table 6 2 HP 8512A Replaceable Parts Continued Part Number Qty Description W37 08512 20017 1 CA AY A6J2 J2 W38 NOT ASSIGNED W39 08512 20019 2 CA AY J2J3 amp J4J5 W40 W48 NOT ASSIGNED W49 08512 20019 CA AY J2J3 amp J4J5 W50 W56 NOT ASSIGNED W57 08513 60014 1 CBL AY RP MB W58 08513 60036 1 CBL AY RP HPIB W59 85102 60193 1 CA ASSY LINE SW W60 08513 60013 1 CA AY FRPNL MBD W61 08510 60102 1 CBL AY TEST SET W62 8120 1348 1 CABLE ASSY 18AWG 3 CNDCT BLK JKT W63 8120 3445 1 HP IB CABLE 1 METER W64 8120 4396 1 CBL C AY SMA 08513 60005 1 BD AY FRONT PNL MISCELLANEOUS MECHANICAL amp CHASSIS PARTS 1 0380 0643 2 STANDOFF HEX 255 IN LG 6 32THD 2 0400 0002 4 GROMMET RND 188 IN ID 312 IN GRV OD 3 0590 0926 4 THREADED INSERT STDF 6 32 188 IN LG SST 4 1251 2942 4 LOCK SUBMIN D CONN 5 2360 0113 3 SCREW MACH 6 32 25 IN LG PAN HD POZI 6 2360 0123 6 SCREW MACH 6 32 625 IN LG PAN HD POZI 7 2420 0001 5 NUT HEX W LKWR 6 32 THD 109 IN THK 8 2420 0022 1 NUT SPCLY 6 32 THD 23 IN THK 354 OD 9 2510 0138 3 SCREW MACH 8 32 3 IN LG PAN HD POZI 10 2510 0270 1 SCREW MACH 8 32 3 25 IN LG PAN HD POZI 11 2580 0003 4 NUT HEX W LKWR 8 32 THD 125 IN THK 12 3050 0139 9 WASHER FL MTLC NO 8 172 IN ID 13 3050 0152 4 WASHER SH
50. L1 BLACK RED GREY TO T1 TRANSFORMER TO S1 FRONT PANEL ON OFF SWITCH Figure 5 9 Wire Connections to Line Module FLI 5 22 Test Set Troubleshooting HP 8514B and 8512A Test Sets Unratioed Power Test SOURCE This procedure allows you to check the output power level of each test set sampler mixer assembly and its associated IF amplifier alone The normal power level display S11 for example is a ratio in this case bl al The network analyzer automatically powers and phase locks a predefined port or ports to make the measurement selected Ratioed measurements provide useful data but they can mask certain malfunctions Assume for example the task is to measure an S parameter at a specific power level If the test set has a 20 dB power hole due to a faulty RF input connector that deficiency would be invisible ratioed out in a ratioed measurement But the data would be incorrect it would not have been taken at the specified power level Similarly troubleshooting system faults in a ratioed measurement mode can be deceptive The solution is to check each channel singly to check the power in an unratioed mode To do so requires specifying which port to drive power to and which channel to achieve phase lock with The following procedures include steps to redefine parameters as required Figure 5 14 through Figure 5 25 show which assemblies are parts of the signal path of each channel Realizing that some assemblies are
51. LDR NO 8 172 IN ID 438 IN OD 14 3050 0227 4 WASHER FL MTLC NO 6 149 IN ID 15 3050 0692 3 WASHER FL MTLC NO 10 202 IN ID 16 3160 0309 1 FINGER GUARD 17 08514 00004 1 REAR PANEL 18 0624 0099 37 SCREW TPG 4 40 375 IN LG PAN HD POZI 19 0624 0100 8 SCREW TPG 4 40 5 IN LG PAN HD POZI STL 20 1400 0757 2 CLAMP CABLE 25 DIA 1 WD PVC 21 2190 0011 8 WASHER LK INTL T NO 10 195 IN ID 22 2200 0105 9 SCREW MACH 4 40 312 IN LG PAN HD POZI 23 2200 0165 22 SCREW MACH 4 40 25 IN LG 82 DEG 24 2360 0115 55 SCREW MACH 6 32 312 IN LG PAN HD PCZI 25 2360 0119 6 SCREW MACH 6 32 438 IN LG PAN HD POZI 26 2360 0333 12 SCREW MACH 6 32 25 IN LG 100 DEG 27 2510 0192 16 SCREW MACH 8 32 25 IN LG 100 DEG 28 2680 0129 8 SCREW MACH 10 32 312 IN LG PAN HD POZI 29 5020 8803 1 FRAME FRONT 30 5020 8804 1 FRAME REAR 31 5020 8837 4 STRUT CORNER 18 HP 8514B and 8512A Test Sets Replaceable Parts 6 27 Table 6 2 HP 8512A Replaceable Parts Continued Part Number Qty Description 32 08505 20132 2 END PLATE ENCL 33 08505 20163 2 ENCLOSURE CKT 34 08512 20005 1 RFI GASKET 35 08513 00001 1 DECK 36 08513 00002 1 TRANSFORMER BRKT 37 08513 00005 1 MTG BRACKET LH 38 08513 00006 1 MTG BRACKET RH 39 08513 00015 1 CAP SPRT PLATE 40 08513 00016 1 BRACKER CKT ENCL 41 08513 20013 1 BRACE DECK 42 08513 20015 1 MOUNTING BAR 43 85102 20054 1 FRONT BEZEL MACH 44 0460 0100 1 TP ACRLC XFR A 1 45 2200 0165 SCREW MACH 4 40 25 IN LG
52. Maximum Operating Power Level Test Port 17 dBm HP 8514B Port 1 and 2 20 dBm HP 8512 Port 1 13 dBm HP 8512A Port 2 The voltages in this test set warrant normal caution for operator safety Nevertheless service should be performed only by qualified personnel Service strategy troubleshooting procedures and replaceable parts information for the HP 8514B and 85124 test sets are in the HP 8510B Service Manual Additional Equipment Required HP 8514B and 8512A Test Sets Table 4 5 on page 4 4 lists additional equipment and accessories required for use with the HP 8514B and 8512A test sets The table notes which items are required to verify the performance of the test sets and which are required to operate them Other equipment may be substituted if its specifications meet or exceed the specifications listed in the critical specifications column General Information 1 11 1 12 General Information HP 8514B and 8512A Test Sets Installation Introduction Initial Inspection HP 8514B and 8512A Test Sets This section explains how to install the HP 8514B and HP 8512A test sets The topics covered include initial inspection environmental considerations positioning and connecting the test set for use and packaging the instrument Refer to the Installation section of the HP 8510 manual for more complete system connection and turn on instructions Inspect the shipping container including cushioning material for damage
53. P 12A MAX FOR UL E38 2110 0565 FUSEHOLDER CAP 12A MAX FOR UL E39 1251 3720 8 CONNECTOR SGL CONT SKT 04 IN BSC SZ RND E40 1251 3720 CONNECTOR SGL CONT SKT 04 IN BSC SZ RND E41 1251 3720 CONNECTOR SGL CONT SKT 04 IN BSC SZ RND E42 1251 3720 CONNECTOR SGL CONT SKT 04 IN BSC SZ RND E43 1251 3720 CONNECTOR SGL CONT SKT 04 IN BSC SZ RND E44 1251 3720 CONNECTOR SGL CONT SKT 04 IN BSC SZ RND E45 1251 3720 CONNECTOR SGL CONT SKT 04 IN BSC SZ RND E46 1251 3720 CONNECTOR SGL CONT SKT 04 IN BSC SZ RND E47 1251 3720 CONNECTOR SGL CONT SKT 04 IN BSC SZ RNO E48 1251 3720 CONNECTOR SGL CONT SKT 04 IN BSC SZ RND F1 2110 0012 2 FUSE 5A 250V NTD 1 25X 25 UL F2 2110 0012 FUSE 5A 250V NTD 1 25X 25 UL F3 2110 0002 1 FUSE 2 0A 250V NTD 1 25X 25 UL FL1 9135 0217 1 LINE MODULE FILTERED J6 1250 0083 2 CONNECTOR RF BNC FEM SGL HOLE FR 50 OHM J8 1250 0083 CONNECTOR RF BNC FEM SGL HOLE FR 50 OHM R1 0757 0394 1 RESISTOR 51 1 196 125W 0 100 T1 9100 4616 1 POWER XFMR W1 W12 SEE Figure 6 8 W13 08513 60133 1 CA AY A3J1 A14J1 W14 08513 60134 1 CA A3J2 J11A7 W15 SEE Figure 6 8 W16 08513 60136 1 CA AY A3J5 J11A5 W17 SEE Figure 6 8 W18 08513 60138 1 AY A3J7 J11A6 W19 SEE Figure 6 8 W20 08513 60140 1 CA AY A3J4 A14J2 W21 08513 60141 1 CA A5J2 A18J4 W22 08513 60142 1 CA AY A5J1 A18J3 W23 08513 60143 1 CA A5J3 A18J6 W24 08513 60144 1 CA AY A12J3 J11A1 W25 08513 60145 1 CA AY A13J3 J11A4 W26 08513 60146 1 CA AY A10J3 J11A
54. PIB NEW 5 08513 60011 1 ATTENUATOR SWITCH DRIVER NEW A6 5180 2749 1 DIRECTIONAL COUPLER NEW AT 5086 7322 2 BIAS TEE PORT 2 NEW AT 5086 6322 2 BIAS TEE PORT 2 REBUILT A8 5180 2749 1 DIRECTIONAL COUPLER A9 5086 7322 BIAS TEE PORT 1 NEW A9 5086 6322 BIAS TEE PORT 1 REBUILT A10 5086 7402 1 B1 SAMPLER ASSY NEW A10 5086 6402 1 B1 SAMPLER ASSY REBUILT A11 5086 7402 1 B2 SAMPLER ASSY NEW A11 5086 6402 1 B2 SAMPLER ASSY REBUILT A12 5086 7402 1 A1 SAMPLER ASSY NEW A12 5086 6402 1 A1 SAMPLER ASSY REBUILT A13 5086 7402 1 A2 SAMPLER ASSY NEW A13 5086 6402 1 A2 SAMPLER ASSY REBUILT A14 5086 7231 1 VTO DRIVER NEW A14 5086 6231 1 VTO DRIVER REBUILT A15 08513 60007 1 BOARD ASSEMBLY REGULATOR A16 08340 60175 2 STEP ATTENUATOR PORT 1 A17 08340 60175 STEP ATTENUATOR PORT 2 A18 5086 7324 1 SWITCH SPLITTER NEW A18 5086 6324 1 SWITCH SPLITTER REBUILT A19 08513 60001 1 BOARD ASSEMBLY MOTHER THE FOLLOWING PARTS ARE NOT SUPPLIED WHEN A19 IS ORDERED A19C1 A19C2 A19C3 A19C4 A19C1 0180 2671 4 CAPACITOR FXD 012F 75 10 3OVDC AL A19C2 0180 2671 CAPACITOR FXD 012F 75 10 3OVDC AL A19C3 0180 2671 CAPACITOR FXD 012F 75 10 30VDC AL A19C4 0180 2971 CAPACITOR FXD 012F 75 10 30VDC AL A19C5 0160 4834 2 CAPACITOR FXD 047UF 10 100VDC CER A19C6 0160 4834 CAPACITOR FXD 047UF 10 100VDC CER A19J1 1251 5745 CONNECTOR 20 PIN M POST TYPE A19J1 DOES NOT INCLUDE A19MP1 amp A19MP2 A19J2 1251 6868 4 CONNECTOR 5 PIN M POST TYPE
55. TS PORT CON 64 5021 3428 2 NUT FLG TS PORT 65 08340 40002 2 MOUNT LED 66 08512 00008 1 CLAMP A 67 08512 00009 1 CLAMP B 68 08512 00010 1 CLAMP C 69 08512 00011 1 CLAMP D 70 08514 00005 2 ATTENUATOR BRACKET 71 08513 00017 2 BRACKET CONV AY 72 85102 00041 1 COVER I F MUX 73 08513 00022 1 CVR ATTEN DRVR 74 85102 00041 1 CVR BLANK IF MUX 75 08514 00028 1 FRONT PANEL 76 08514 00014 1 SUB PANEL 77 08514 00008 1 MOUNTING BRACKET 78 08514 00007 1 SW MNTG PLATE 79 08514 20005 1 BLOCK MTG CPLR 80 2510 0195 6 SCREW MACH 8 32 375 IN LG 100 DEG 81 7120 4835 1 LABEL INFORMATION 75 IN WD 2 IN LG PPR 82 7121 2527 1 LABEL WARNING 1 IN WD 7 IN LG PPR 83 5021 8496 2 TRIM FRNT HNDL 84 5040 7201 4 FOOT BOTTOM 85 5041 8802 1 STRIP TRIM TOP 86 5040 7221 4 FOOT REAR 87 5062 3747 1 COVER BTM 18 FM 88 5061 9457 1 COVER AY SIDE 89 5061 9499 2 HANDLE AY FRONT 90 08513 00040 1 TEST SET CVR TOP 91 08513 00041 1 COVER SIDE PERF 92 3050 0105 3 WASHER FL MTLC NO 4 125 IN ID 93 0380 0010 4 SPACER RND 625 IN LG 18 IN ID 94 2360 0127 1 SCREW MACH 6 32 875 IN LG PAN HD PCZI 95 08513 00017 1 CONV ASSEY BRACKET 96 08514 20024 2 PORT FLANGE HP 8514B and 8512A Test Sets Replaceable Parts 6 9 hidden A20 A18 M6 A5 19 4 15 A13 2 hidden A12 ATI 4 hidden C3 C2 C1 Al A6 A10 A9 14 AT hidden hidden hidden Figure 6 1 8514B Top View Showing Loca
56. a frequency counter and a voltmeter check the VTO fundamental frequency and A3 summing amplifier output as follows Disconnect the Test Set IF Interconnect cable Using a BNC to snap on cable provided in the service kit connect the frequency counter to A14J1 labeled AUX on the board assembly Check that 14 is between 165 MHz and 195 MHz Disconnect the cable to A3J4 The VTO frequency should be between 150 MHz and 190 MHz Check that A3JA is between 5 6 and 6 8 Vdc If the VTO frequency is not correct but the voltage at A3J4 is correct suspect a bad VTO If the voltage at A3J4 is not correct suspect a bad A3 summing amplifier assembly assuming the HP 85102 is working 2 Usea power supply and a frequency counter to check the VTO as follows Inject a 1 to 12V DC voltage in 1 volt steps into the A14 VTO drive A14J2 Monitor 14 to verify that the steps through its range of 65 MHz to 300 MHz about 21 3 MHZ volt Figure 5 3 illustrates the relationship of voltage at A14J2 to VTO oscillation frequency 300MHz 250 MEASURED FREQUENCY 200 AT A14 Jt VTO AUX 150 100 50 12 11 10 9 8 7 6 5 4 3 2 1 0 NEGATIVE DC VOLTAGE A14J2 Figure 5 3 VTO Voltage Frequency Relationship 5 6 Test Set Troubleshooting HP 8514B and 8512A Test Sets Test Set Troubleshooting Using Time Domain Time domain response of the test set can be used to identify problems in the RF path The p
57. able Parts 6 19 We Wi 5 Places Figure 6 9 Parts Unique to HP 8514B Option 002 nererence HP Part Number Qty Description Designation w1 08514 20022 1 A18J1 A6J2 CABLE ASSY W2 08514 20023 1 A18J7 A8J2 CABLE ASSY 1 2360 0113 5 MACHINE SCREW 8 32X0 25 2 1400 0054 5 OPTION 002 CABLE CLAMP 3 3050 0139 5 FLAT WASHER 0 172 ID 6 20 Replaceable Parts HP 8514B and 8512A Test Sets torque to torque to 281 304 N cm 473 495 N cm Coupler Coupler 25 27 in Ib 42 44 in Ib Nut Flange NOTE Center pin is not replaceable by itself Figure 6 10 8514B Ports and 2 Replaceable Parts Reference HP Part Number Qty Description Designation 1 5062 1272 2 TEST PORT CONNECTOR ASSY 2 5062 1245 2 3 5 MM NUT ASSEMBLY HP 8514B and 8512A Test Sets Replaceable Parts 6 21 was Way W46 WA8 xS Figure 6 11 Parts Unique to 8514B Option 003 HP PartNumber Qt Description Designation y P W45 08514 20057 1 CABLE RF A6J3 A10J2 W46 08514 20058 1 CABLE RF A11J2 A17J2 W47 08514 20059 1 CABLE RF A13J2 J2 W48 08514 20060 1 CABLE RF A8J3 A18J7 W49 08514 20061 1 CABLE RF A12J2 J5 AT3 33340CZ 1 3 5 MM SHAPED PAD 6 22 Replaceable Parts HP 8514B and 8512A Test Sets Re cost eee Figure 6 12 HP 8514B Option 002 003 Parts Reference HP Part Number Qty Description Designation W45 SEE Fi
58. afety Precautions on page 1 9 for more information on preventing ESD The assemblies handled in this procedure are very sensitive to damage by static electricity They may or may not continue to function if subjected to an electrostatic discharge In any case an electrostatic discharge will impair the reliability of these assemblies Always perform the following steps in order The frequency converter is especially sensitive to electrostatic discharge Wear a ground strap that is connected to earth ground when performing this procedure NOTE 1 Remove the semi rigid cables from the samplers 2 Remove the in line attenuators from the samplers 3 Remove all flexible cables from the frequency converter by gently pulling on the gold connector 4 Unplug the ribbon cable near the front panel 5 Unplug the harnessed multi colored wire and socket assemblies 6 Remove the four 4 frequency converter mounting plate screws and the frequency converter bracket screw that fastens the frequency converter to the chassis Lift the frequency converter out of the test set 7 Remove the frequency converter bracket by removing the two 2 pozidriv screws before sending the frequency converter in for repair Torque all SMA connections to 56 N cm 5 in Ib with the 5 16 torque wrench HP 8514B and 8512A Test Sets Test Set Troubleshooting 5 15 5 Sampler 6 Assembly Remove the frequency converter 4 from the test
59. applies directly to instruments with the same or lower serial number prefix indicated in the front section of this manual Instruments with serial number prefixes higher than indicated may be documented in a manual update supplement Miscellaneous 8 1
60. ative humidity up to 90 at 65 maximum dry bulb temperature and at altitudes up to 15 240 metres 50 000 feet 2 2 Installation HP 8514B and 8512A Test Sets gt 2 HP IB Cable 3 3 ft long 1 Test Set Interconnect Cable 3 RF Cable Reference Port Extension Cables Short SMA M SMA E 11 7 Open End Wrench 6 Torque Wrench 20 mms 8512 10 Clamp s HP 8514B Figure 2 1 Accessories Supplied with HP 8514B and HP 8512A Item HP Model or Part Number HP 8514B HP 8512A Power cord 1 8120 1348 8120 1348 1 Test set IF interconnect cable 08510 60102 08510 60102 2 HPIB cable 8120 3445 8120 3445 3 RF cable flexible 08513 60009 08513 60009 4 Short reference port extension cables 2 08512 20019 08512 20019 5 Long reference port extension cables 2 08514 20013 6 Torque wrench 8710 1764 7 Open end wrench 1 2 in X 9 16 in 8710 1770 8 Type N m to SMA m adapter 1250 1894 1250 1894 Attenuator 20 dB 7 mm 08512 60002 10 Anti rotation clamps 2 08515 60003 Specifications and Performance Verification Program and Data Disk 08510 10033 08510 10033 Operating and Service Manual 08515 90014 08515 90014 Principles of Microwave Connector Care 1 5954 1566 5954 1566 1 Not shown HP 8514B and 8512A Test Sets Installation 2 3 OPTION 908 RACK MOUNT KIT 3 Remove f
61. calibration measurements are traceable to the United States National Institute of Standards and Technology NIST formerly NBS to the extent allowed by the Institute s calibration facility and to the calibration facilities of other International Standards Organization members This Hewlett Packard system product is warranted against defects in materials and workmanship for a period corresponding to the individual warranty periods of its component products Instruments are warranted for a period of one year During the warranty period Hewlett Packard Company will at its option either repair or replace products that prove to be defective Warranty service for products installed by HP and certain other products designated by HP will be performed at Buyer s facility at no charge within HP service travel areas Outside HP service travel areas warranty service will be performed at Buyer s facility only upon HP s prior agreement and Buyer shall pay HP s round trip travel expenses In all other areas products must be returned to a service facility designated by HP For products returned to HP for warranty service Buyer shall prepay shipping charges to HP and HP shall pay shipping charges to return the product to Buyer However Buyer shall pay all shipping charges duties and taxes for products returned to HP from another country HP warrants that its software and firmware designated by HP for use with an instrument will execute its programming i
62. common to two or all four channels is a powerful troubleshooting tool Figure 5 11 and Figure 5 14 through Figure 5 25 following these procedures show typical traces TEST SET HP 85102 Figure 5 10 HP 8514B and 8512A Test Sets AMP MULTIPLEXER Simplified Signal Path of Unratioed Power Test Test Set Troubleshooting 5 23 HP 8512A Test Set NOTE For an HP 8512A check the b1 b2 trace between 2 GHz and 18 GHz Below 2 GHz the coupler response rolls off rapidly in the b1 reflection trace al Test b1 Reflection Test b2 Thru Test 5 24 Test Set Troubleshooting Remove any cables or DUTS from the test set input ports Press PRESET STIMULUS MENU on the HP 85102 to access the STIMULUS menu a HP 8340 41 systems press STEP on the HP 85101 to set the source to step mode b 8350B systems press SWEEP TIME and use the entry keys to set the sweep time to 200 ms Press PARAMETER MENU USER 1 a1 to see the unratioed power trace For an HP 85124 the trace level should decrease from 20 5 dB at low frequency to 35 5 dB at high frequency Connect an open or a short to port 1 Press USER 4 b1 and check that the trace for each is within the limits described above Connect a thru between port 1 and port 2 connect pad to port 1 and test port return cable between pad and port 2 For an HP 8512A use a 20 dB system pad Press USER 2 b2 and check that the trace
63. e aluminum shield which covers the couplers disconnect any wires that cross the coupler and remove the two screws which attach the coupler to the test set chassis 3 Disconnect the semi rigid cable from the coupler to the sampler 4 Carefully loosen the nut on the front of the test set with the 1 in torque wrench Remove the nut and washer 5 Move the coupler away from the front panel and lift it out of the test set 6 Remove any brackets before sending the coupler to HP for repair Reflection transmission test sets use a splitter rather than a combination switch splitter Both devices are installed in the same place in the various test sets 5 14 Test Set Troubleshooting 1 Remove the semi rigid cables from the switch splitter with the 5 16 in wrench Reposition any other cables as required to ease removal 2 Remove the four 4 screws which attach the switch splitter mounting bracket to the chassis 3 Remove the switch splitter and bracket from the test set 4 Remove the bracket from the switch splitter before sending the switch splitter to HP for repair HP 8514B and 8512A Test Sets 4 Frequency Converter CAUTION The frequency converter consists of a VTO voltage tuned oscillator assembly and three or four samplers Electrostatic discharge ESD can damage or destroy electronic components All work on electronic assemblies should be performed at a static safe workstation Refer to Operating and S
64. e by the U S Government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 for DOD agencies and subparagraphs c 1 and c 2 of the Commercial Computer Software Restricted Rights clause at FAR 52 227 19 for other agencies Hewlett Packard Company Santa Rosa Systems Division 1400 Fountaingrove Parkway Santa Rosa CA 95403 1799 U S A This manual applies directly to HP 8514B test sets with serial prefix 2706A and to HP 8512A test sets with serial prefix 2631A For additional information about serial numbers refer to Instruments Covered By Manual in the General Information section of this manual Copyright Hewlett Packard Company 1987 HP 8514B and 8512A Test Sets What You ll Find in This Manual HP 8514B and 8512A Test Sets Section I HP 8514B or 8512A Test Set Information General information Installation Operation Specifications and characteristics Section II HP 8514B or 8512A Troubleshooting Information Test set troubleshooting assembly replacement procedures Replaceable parts and accessories Service Miscellaneous including o Performance tests o Adjustments o Manual Backdating Warranty Certification Warranty Hewlett Packard Company certifies that this product met its published specifications at the time of shipment from the factory Hewlett Packard further certifies that its
65. ection b Reflection Figure 5 12 User Signal Paths in Test Sets 1 of 2 5 28 Test Set Troubleshooting HP 8514B and 8512A Test Sets 7 2 u E a lt wz lt m 5 z jx 2 x 9 2 2 5 2 2 Tq n x T C b Thru b Thru Figure 5 13 User Signal Paths in Test Sets 2 of 2 HP 8514B and 8512A Test Sets Test Set Troubleshooting 5 29 Uzeri iog MAG REF 22 06 dB 1 10 0 30 772 BE LUN MARKER 1 20 0 GHz A LLL ea 0 045000000 GHz START 20 000000000 GHz STOP Figure 5 14 Typical HP 8514B Option 002 003 al Reflection Trace Figure 5 15 HP 8514B Option 002 003 al Reflection Signal Path 5 30 Test Set Troubleshooting HP 8514B and 8512A Test Sets User3 leg MAG REF 21 0 dB 1 10 0 32 229 dB MARKER 1 0 0 START 845000000 GHz STOP 20 000000000 GHz Figure 5 16 Typical HP 8514B Option 002 003 a2 Reflection Trace VTO SENSE PRETUNE 01 TUNE RF IN Figure 5 17 HP 8514B Option 002 003 a2 Reflection Signal Path HP 8514B and 8512A Test Sets Test Set Troubleshooting 5 31 START 845808000 GHz sTOP 20 000000000 GHz Figure 5 18 Typical HP 8514B Option 002 003 b1 Reflection Trace at SENSE PRETUNE TUNE RF IN b2 b1
66. eet before rack mounting WITH HANOLES REMOVED HP Part Number 5061 9677 FRONT OF 1 Remove trim INSTRUMENT screws and handle 2 Attach rack flange with pan head machine screws INSTRUMENT OPTION 913 RACK MOUNT KIT FOR INSTRUMENTS WITH PREVIOUSLY ATTACHED FRONT HANDLES HP Part Number 5061 9771 3 Remove feet before rack mounting FRONT OF 1 Remove trim and screws INSTRUMENT 2 Attach rack flange with pan head machine screws Figure 2 2 Attaching Rack Mounting Hardware 2 4 Installation HP 8514B and 8512A Test Sets Preparation for Use Positioning the Test Set Connecting the Test Set HP 8514B and 8512A Test Sets A work surface should be provided for use with the test set whether it is rack mounted or used on a bench To install the flanges to rack mount the instrument with or without handles in a standard 19 inch rack refer to Figure 2 2 The recommended rack is the HP 85043A Instructions for rack mounting the test set in a system configuration with the HP 8510 are provided in the HP 8510 installation section When installing the test set for use on a bench place it on a grounded anti static work surface to lessen the chance of ESD damage The anti static surface should extend far enough in front of the test set to provide effective protection at the test ports and cable ends Refer to Operating and Safety Precautions on page 1 9 Mating Connectors HP 8514B Ports 1 and 2
67. eference designator keys the part listed to the illustration The part number listed is HP s part number Quantity refers to the total number of that part in the instrument The description is a brief written description of the part and may be used for ordering purposes The replaceable parts of ports 1 and 2 of the HP 8514B are identified in Figure 6 10 The replaceable parts of ports 1 and 2 of the HP 8512B are identified in Figure 6 19 Additional center conductor and outer nut replacement information is in Service Note 8512A 4A For information concerning the repair of 3 5 mm rear panel connectors refer to the Test Set Troubleshooting section of the HP 8510 Service Manual or Service Note 8511A 1 Reference Designations A assembly J electrical connector jack AT attenuator MP miscellaneous part B fan R resistor capacitor transformer E miscellaneous electrical part W cable wire F fuse X socket FL filter More comprehensive tables of reference designators and abbreviations are behind the Replacement Parts tab of the HP 8510B Service Manual Replaceable Parts 6 3 Table 6 1 8514B Replaceable Parts Part Number Qty Description A1 08513 60005 1 BOARD ASSEMBLY FRONT PANEL A1DS1 1990 0858 2 LED LAMP LUM INT 15UCD IF 25MA MAX A1DS2 1990 0858 LED LAMP LUM INT 15UCD IF 25MA MAX A2 SEE Figure 6 8 A3 08513 60008 1 VTO SUMMING AMPLIFIER BD ASSY NEW A4 08514 60029 1 BOARD ASSEMBLY H
68. en prompts and messages that you will see on the display of an instrument The HP 8516A will display the message CAL1 SAVED Used for labeled keys on the front panel of an instrument or on a computer keyboard Press Return Used for simulated keys that appear on an instrument display Press Prior Menu Used to indicate text that you will enter using the computer keyboard text shown in this typeface must be typed exactly as printed Type LOAD PARMFILE Used for examples of programming code endif ifndef NO CLASS Used for a subdirectory name or file path Edit the file usr local bin sample txt Used to show messages prompts and window labels that appear on a computer monitor The EDIT PARAMETERS window will appear on the screen Used for menus lists dialog boxes and button boxes on a computer monitor from which you make selections using the mouse or keyboard Double click EXIT to quit the program Declaration of Conformity DECLARATION OF CONFORMITY according to ISO IEC Guide 22 and EN 45014 Manufacturer s Name Hewlett Packard Co Manufacturer s Address 1400 Fountaingrove Parkway Santa Rosa California 95403 U S A Declares that the product Product Name S Parameter Test Set Model Numbers HP 8514B Product Options This declaration covers all options of the above product s Conforms to the following product specifications Safety IEC 348 1978 HD 401 1980 CAN CSA 22 2 No 231 Series M89 EMC C
69. er to HP 8510 installation manual for additional information 3 Not required for manual performance tests with HP 8510A 4 4 Specifications HP 8514B and 8512A Test Sets Test Set Troubleshooting HP 8514B and 8512A Test Sets This chapter consists of procedures for checking the following Test Set Temperature Check All Connections Check Power Supply Regulator Fuses and Switches Test Set Self test Indicators Check VTO Driver LO Test Set Troubleshooting Using Time Domain Test Set Assembly Replacement Procedures 3 5 mm RF Connector Repair Unratioed Power Test The information in this section is presented as an aid in troubleshooting the HP 8512A HP 8514A and HP 8514B test sets If you are not certain that the problem with your system is due to a faulty test set read the sections titled Service Overview and Built in Diagnostics in this manual Continue with this section only if you know the test set is faulty For specific information about the HP 8514A refer to the material in the HP 8510A manual set Test Set Troubleshooting 5 1 Test Set Temperature CAUTION The processor on the A4 HP IB assembly monitors the test set temperature with a comparator on the A3 VTO summing amplifier The temperature sensor is located on the 14 VTO driver assembly If the temperature of the VTO driver exceeds 85 C the HP 85101 displays the Test Set Too Hot prompt TEST SET TOO HOT means turn off the test set immediately This
70. est Sets THUMBSCREW ALIGN THUMBSCREW WITH COUNTER SUNK HOLE COUNTER SUNK HOLE Figure 3 9 HP 8514B and 8512A Test Sets 5 Make sure that the thumbscrew is aligned with the counter sunk hole in the clamp body Push the clamp toward the test set front panel and then tighten the thumbscrew with your fingers The cable cannot be damaged by tightening the thumbscrew too tightly Refer to Figure 3 9 CORRECT INCORRECT THUMBSCREW COUNTER SUNK HOLE Aligning the Thumbscrew with the Counter Bored Hole 6 Repeat steps 1 through 5 for the other clamp This completes the anti rotation clamp installation procedure Refer to the installation section of the test set operating and service manual for instructions to replace the internal O ring in the anti rotation clamp Operation 3 17 3 18 Operation HP 8514B and 8512A Test Sets Specifications Specifications describe the warranted performance of the instrument The electrical specifications of the HP 8514B and HP 8512A test sets with an HP 8510B network analyzer are defined in the Specifications section of the HP 8510 System Manual Specifications for HP 8510A systems are defined in General Information volume 1 of the HP 8510A manual set Mechanical Specifications Table 4 1 Mechanical Specifications Test Ports Front Panel NMD 3 5 mm connector center pin recession 0 005 mm to 0 056 mm 0 0002 in to 0 0022 in NOTE
71. et Limited Instrument State does not include the number of the active test set a Cal Set which does not apply to the current test set can HP 8514B and 8512A Test Sets Operational Checks Performance Verification HP 8514B and 8512A Test Sets be turned on without any HP 8510 caution messages appearing This will cause errors in the displayed data because incorrect error coefficients are applied to the measured data It may be convenient to store a Hardware State file and an Instrument State file for each combination of test set and cal set You may also store your Hardware State file on a tape or disk for future use To change the configuration simply recall the appropriate Hardware State file which sets the Address of Test Set and issues the RF switch command then the appropriate Instrument State file which recalls the Cal Set To check operation of a multiple test set configuration first connect a device with a known response at test set number 1 then press HP 8510 LOCAL TEST SET ADDRESS of TEST SET enter the address of test set number 1 this would be 20 then press x1 The test set number 1 measurement should appear Press DISPLAY DATA4EMEMORY DISPLAY DATA and MEMORY to store the trace for later comparison Now use ADDRESS of TEST SET to select test set number 2 then switch back to test set number 1 Observe any difference in the response between the stored trace and the result after switching back and forth
72. gure 1 3 Example of Static Safe Workstation Reducing ESD Damage The following suggestions may help reduce ESD damage that occurs during testing and servicing operations Before connecting any coaxial cable to an instrument connector for the first time each day momentarily ground the center and outer conductors of the cable Personnel should be grounded with a resistor isolated wrist strap before touching the center pin of any connector and before removing any assembly from the unit Be sure that all instruments are properly earth grounded to prevent a buildup of static charge Table 1 1 Static Safe Accessories lists static safe accessories that can be obtained from Hewlett Packard using the HP part numbers shown 1 10 General Information HP 8514B and 8512A Test Sets Table 1 1 Operating Power Level Table 1 2 Service Static Safe Accessories HP Part Number Description 9300 0797 Set includes 3M static control mat 0 6 m X 1 2 m 2 ft X 4 ft and 4 6 cm 15 ft ground wire The wrist strap and wrist strap cord are not included They must be ordered separately 9300 0980 Wrist strap cord 1 5 m 5 ft 9300 1383 Wrist strap color black stainless steel without cord has four adjustable links and a 7 mm post type connection 9300 1169 ESD heel strap reusable 6 to 12 months Do not exceed the front panel operating level power input as noted Maximum Operating Power Level
73. gure 6 11 W47 SEE Figure 6 11 W48 SEE Figure 6 11 W49 SEE Figure 6 11 W50 08514 20090 1 CABLE RF A8 TO A11 W51 08514 20091 1 CABLE RF A6 TO A18 AT3 SEE Figure 6 11 HP 8514B and 8512A Test Sets Replaceable Parts 6 23 Table 6 2 HP 8512A Replaceable Parts Part Number Qty Description 1 08513 60005 1 BOARD ASSEMBLY FRONT PANEL A1DS1 1990 0858 2 LED LAMP LUM INT 15UCD IF 25MA MAX A1DS2 1990 0858 LED LAMP LUM INT 15UCD IF 25MA MAX A2 SEE Figure 6 8 A3 08513 60008 BOARD ASSEMBLY VTO SUMMING AMPLIFIER A4 08513 60002 1 BOARD ASSEMBLY HP IB A5 NOT ASSIGNED A6 5080 0351 1 DIRECTIONAL COUPLER 7mm connector is replaceable see Figure 9 AT A9 NOT ASSIGNED A10 5086 7402 1 B1 SAMPLER ASSEMBLY NEW A10 5086 6402 B1 SAMPLER ASSEMBLY REBUILT A11 5086 7402 1 B2 SAMPLER ASSEMBLY NEW A11 5086 6402 B2 SAMPLER ASSEMBLY REBUILT A12 5086 7402 1 A1 SAMPLER ASSEMBLY NEW A12 5086 6402 A1 SAMPLER ASSEMBLY REBUILT A13 NOT ASSIGNED A14 5086 7231 1 VTO DRIVER NEW A14 5086 6231 1 VTO DRIVER REBUILT A15 08513 60007 1 REGULATOR BOARD ASSEMBLY A15 08515 69007 1 REGULATOR BOARD ASSEMBLY A16 A17 NOT ASSIGNED A18 5086 7408 1 POWER SPLITTER A19 08513 60001 1 BOARD ASSEMBLY MOTHER THE FOLLOWING PARTS ARE NOT SUPPLIED WHEN A19 IS ORDERED A19C1 A19C2 A19C3 A19C4 A19C1 0180 2671 4 CAPACITOR FXD 012F 75 10 30VDC AL A19C2 0180 2671 CAPACITOR FXD 012F 75 10 30VDC AL A19C3 0180 2671 CAPACITOR FXD 012F 75 10 30VDC AL A1
74. ies Available NOTE Additional HP 8510 system accessory information is located in the HP 8510 manual set Calibration Verification and Adapter Kits Hewlett Packard offers several calibration kits suitable for calibrating an HP 8510 8514B or 8512A when making error corrected measurements Each calibration kit noted below includes a set of precision standards to calibrate an HP 8510 system in the indicated interface Additional information is located in the System and Documentation Overview section of the HP 8510B System Manual and volume 1 of the HP 8510A manual set Connector Type Calibration Kit Verification Kit Adapter Kit 3 5 mm HP 85052B E HP 85053B 7 mm HP 85050B C D HP 85051B Type N 500 HP 85054B HP 85055A 3 5 to 7 mm HP 85130A B These adapters attach directly to the 3 5 mm test ports RF Cables The HP 85131D 3 5 mm Test Port Return Cable Set is a pair of 21 inch long cables specified from DC to 26 5 GHz Typically it is used with the HP 8514B One of the cables has 3 5 mm f connectors the other cable has one 3 5 mm f and one 3 5 mm m connector The HP 85132C 7 mm Test Port Return Cable is a single 36 inch cable for measurements where the device is connected directly to one test port It is typically used with the HP 8512A The cable has two 7 mm connectors Its frequency range is DC to 18 GHz 1 8 General Information HP 8514B and 8512A Test Sets Transistor Test Fixture K
75. igure 6 12 HP 8512A replaceable parts are identified by Table 6 2 and Figure 6 7 Figure 6 8 and Figure 6 13 through Figure 6 19 HP 8514B and 8512A Test Sets Replaceable Parts 6 1 Exchange Assemblies Available The items below are replaceable on a rebuilt exchange basis at a cost saving They are not field repairable Defective assemblies must be returned for credit to realize the cost savings Thus assemblies required for spare parts stock should be ordered by the new assembly part number which is included in the replaceable parts list of this section See the parts list for the orderable part numbers A2 IF multiplexer board assembly A3 VTO summing amplifier board assembly A4 HPIB board assembly 5 attenuator switch driver assembly A6 coupler 7 bias tee 8 coupler 9 bias tee 10 sampler assembly input b1 All sampler assembly input b2 12 sampler assembly input a1 13 sampler assembly input a2 14 VTO driver assembly 15 regulator board assembly 16 step attenuator 17 step attenuator A18 switch splitter 1l HPS8514B only 6 2 Replaceable Parts HP 8514B and 8512A Test Sets Replaceable Parts Lists HP 8514B and 8512A Test Sets The replaceable parts lists consist of illustrations and tables Use the illustrations to identify the part to be ordered use the tables to determine the ordering information Each table is arranged in alpha numerical order by reference designator The r
76. important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met gt Safety Earth Ground HP 8514B and 8512A Test Sets When you see this symbol on your instrument you should refer to the instrument s instruction manual for important information Indicates hazardous voltages Indicates an earth ground terminal This is a Safety Class I product provided with a protective earthing terminal An uninterruptible safety earth ground must be provided from the main power source to the product input wiring terminals power cord or supplied power cord set Whenever it is likely that the protection has been impaired the product must be made inoperative and secured against any unintended operation Vii Before Applying Verify that the product is configured to match the available main power Power source as described in the input power configuration instructions in this manual If this product is to be powered by autotransformer make sure the common terminal is connected to the neutral grounded side of the ac power supply viii HP 8514B and 8512A Test Sets Typeface Conventions Italics Instrument Display Keycap Softkey User Entry Path Name Computer Display HP 8514B and 8512A Test Sets Used to emphasize important information Used for the title of a publication Used to indicate a variable Type LOAD BIN filename Used to show on scre
77. ion 1 5 Table 4 2 on page 4 2 and Table 4 3 on page 4 3 list additional characteristics of the HP 8514B and 8512A respectively Figure 1 2 shows the HP 8514B in a typical measurement set up 415 SOURCE CONTROL TEST SET INTER CONNECT OOOO00 oso 95089 TEST SET HP 85198 HP 8348 OR 8341 SYNTHESIZED NETWORK ANALYZER Figure 1 2 Typical HP 8514B Measurement Set up Options Option 001 This option adds IF switching capability to allow up to four test sets to be connected to the HP 8510B at the same time The test set in use is selected from the HP 8510B front panel The 20 MHz IF signal is transmitted from the standard test set through the option 001 test set s to the network analyzer IF switching is performed automatically by the option 001 test set s without reconnections Option 002 HP 8514B only This option deletes the 90 dB programmable step attenuators and the dc bias tees Note that bias can be applied externally using the HP 11612A bias tee if bias is required but attenuation not Option 003 HP 8514B only This high forward dynamic range configuration is described in detail in this section under Description and Operating Characteristics of the Instrument on page 1 5 Option 002 003 HP 8514B only This option is a combination of option 002 and option 003 which were previously described 1 6 General Information HP 8514B and 8512A Test Sets NOTE Option 908 This opt
78. ion supplies the test set with the parts required to rack mount it with handles removed Refer to the Installation section of this manual for additional information Option 910 This option provides a duplicate test set manual Option 913 This option supplies the test set with the parts required to rack mount it with handles Refer to the Installation section of this manual for additional information Option W03 Warranty Conversion Option W03 converts the standard one year return to Hewlett Packard warranty to a 90 day on site warranty W03 can only be ordered at the time of instrument purchase Instruments ordered with option W03 are identified on the serial number label or on a special identification label supplied with the instrument Option W30 Extended Service Option W30 adds two additional years of return to HP service to follow the first year of warranty Option W30 can be ordered only at the time of purchase Instruments ordered with option W30 are identified on the serial number label or on a special identification label supplied with the instrument Additional system warranty information is included in the HP 8510 manual set HP 8514B and 8512A Test Sets General Information 1 7 Accessories Accessories Supplied Figure 2 1 on page 2 3 shows the accessories supplied with the HP 8514B and 8512A test sets The accessories with part numbers are listed in the Installation section for both test sets Accessor
79. is within the same limits If one or more channels appear faulty refer to the procedure titled If Any User Channel Looks Bad on page 5 36 HP 8514B and 8512A Test Sets HP 8514B Test Set NOTE For an HP 8514B check the b1 and b2 trace between 2 GHz and 20 GHz Below 2 GHz the coupler rolls off rapidly Sampler Test NOTE 1 Press PRESET STIMULUS MENU on the HP 85102 to preset the HP 8510 and access the STIMULUS menu a HP 8340 41 systems press STEP on the HP 85101 to put the source in step mode b 8350B systems press SWEEPTIME and use the entry keys to set the sweep time to 200 ms To check all of the samplers in a S parameter test set first redefine the a2 and b2 phase lock and drive paths Press PARAMETER MENU User 3 a2 REDEFINE PARAMETER DRIVE Port 2 PHASELOCK a2 REDEFINE DONE to redefine a2 Press User 2 b2 REDEFINE PARAMETER DRIVE Port 2 PHASELOCK a2 REDEFINE DONE to redefine b2 Connect an open or short to port 1 and port 2 Press User 1 a1 User 2 b2 User 3 a2 and User 4 b1 to check the samplers indicated Each trace should be within the following limits For an HP 8514B the traces should decrease from 20 5 dB at low frequency to 27 5 dB at high frequency The RF signal paths are shown in Figure 5 11 through Figure 5 25 b1 Thru Test b2 Thru Test HP 8514B and 8512A Test Sets 5 Connecta thru two RF cables from port 1 to
80. it The HP 85041A Transistor Test Fixture Kit TTF is a comprehensive measurement system for testing and characterizing stripline packaged microwave transistors Although it has 7 mm connectors and a frequency range limited to 18 GHz the TTF may be easily adapted for use with the HP 8514B Please consult with your local HP Systems Engineer for specific recommendations Operating and Safety Precautions Electrostatic Discharge Information WARNING Electrostatic discharge ESD can damage or destroy electronic components All work on electronic assemblies should be performed at a static safe work station Figure 1 3 shows an example of a static safe work station using two types of ESD protection 1 Conductive table mat and wrist strap combination 2 Conductive floor mat and heel strap combination Both types when used together provide a significant level of ESD protection Of the two only the table mat and wrist strap combination provides adequate ESD protection when used alone To ensure user safety the static safe accessories must provide at least 1 MQ of isolation from ground Refer to Table 1 1 Static Safe Accessories for information on ordering static safe accessories These techniques for a static safe work station should not be used when working on circuitry with a voltage potential greater than 500 volts HP 8514B and 8512A Test Sets General Information 1 9 Building Ground 1 Meg Ohm Resistor Fi
81. lots below show typical time domain responses of the HP 8512A 8513A 8514A B and 8515A test sets These can be used as rough standards when trying to locate a problem in the RF path Keep in mind that the absolute location in time and absolute height of the responses will vary from test set to test set The significant factor is the relative height of the main impulse determined by the calibrated short and the discontinuities Discontinuities that may be causing a problem will usually stand out as being much greater than the typical response Set up the system as follows to obtain a time domain trace 1 Connect a short or shielded open to the test set port 1 2 Press PRESET DOMAIN TIME BAND PASS STIMULUS MENU NUMBER OF POINTS 4 0 1 S11 LOG MAG 3 Set the START STOP TIME SCALE and REF VALUE as indicated in Table 5 2 below Table 5 2 Suggested Parameter Values for Time Domain Troubleshooting Test Set Start Time Stop Time Scale REF Value Refer to Figure HP 8512A 1 0 ns 11 0 ns 10 dB 20 dB Figure 5 4 HP 8514A B 6 0 ns 6 0 ns 5 dB 20 dB Figure 5 5 HP 8514B and 8512A Test Sets 4 For the HP 8514A or 8515A you can check the port 2 responses using the same set up as described above except connect the termination to port 2 and select S22 instead of 511 Peaks in the trace that are Test Set Troubleshooting 5 7 significantly greater than those shown indicate a possible loose
82. ly switched to the S22 or 12 mode and source power is switches to Port 2 Bias Fuse HP 8514B only The fuse which limits bias applied to Port 2 is within this holder see the instrument front panel or the replaceable parts list for the value of the fuse F2 Port 2 In the HP 8514B this test port transmits RF energy from the source to the DUT and receives reflected RF energy from the DUT In the HP 85124 this port only receives transmitted from Port 1 RF energy The received RF energy is input directly to a sampler within the instrument Operation 3 3 Rear Panel Features Figure 3 2 Rear Panel Features of HP 8514B upper and HP 8512A 10 Line module This assembly houses the line cord connector line fuse and line voltage selector Pull out the right side of the line module cover to replace or change the fuse or to change the voltage selection Note that the voltage selector drum must be removed to rotate it to a different voltage setting Recommended fuse values are printed on the rear panel 11 Extension A This pair of 3 5 mm connectors holds the reference port extension cable RPEC supplied used to equalize the length of the reference signal a2 sampler path with the test signal b2 sampler path 3 4 Operation HP 8514B and 8512A Test Sets HP 8514B and 8512A Test Sets When the DUT is connected to Port 2 with any of the recommended cables connect the long RPEC to Extension A 12 Extension B
83. ns are fully understood and met A WARNING notice denotes a haz ard It calls attention to an operat ing procedure practice or the like that if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met Operating and Service Manual HP 8514B S Parameter and HP 8512A Reflection Transmission Test Sets HEWLETT FA PACKARD HP part number 08514 90051 Printed in USA April 1996 Notice Serial Numbers The information contained in this document is subject to change without notice Hewlett Packard makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Hewlett Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett Packard This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without prior written consent of Hewlett Packard Company Restricted Rights Legend Use duplication or disclosur
84. nstructions when properly installed on that instrument HP does not warrant that the operation of the instrument or software or firmware will be uninterrupted or error free LIMITATION OF WARRANTY The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer Buyer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation or maintenance NO OTHER WARRANTY IS EXPRESSED OR IMPLIED HP SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EXCLUSIVE REMEDIES THE REMEDIES PROVIDED HEREIN ARE BUYER S SOLE AND EXCLUSIVE REMEDIES HP SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER BASED ON CONTRACT TORT OR ANY OTHER LEGAL THEORY HP 8514B and 8512A Test Sets Assistance Product maintenance agreements and other customer assistance agreements are available for Hewlett Packard products For assistance call your local Hewlett Packard Sales and Service Office refer to Support and Service HP 8514B and 8512A Test Sets Support and Service US Field Operation Headquarters Hewlett Packard Company 19320 Pruneridge Avenue Cupertino CA 95014 USA 800 752 0900 Southern California Hewlett Packard Company 1421 South Manhattan Avenue Fullerton CA 92631 714 999 6
85. que is 56 N cm 5 in Ib for the RF cable to test set RF input connection Anti Rotation Clamps HP 8514B only Use these clamps to stabilize the test port RFcable connection Connect the test port cables to the test ports and tighten them as specified in the cable manual Loosen the anti rotation clamp thumbscrew sufficiently to slip the clamp over the cable and up to the front panel The clamp end with the flats should come to rest on the flats of the test port shoulder Finger tighten the thumbscrews to prevent further loosening or tightening of the test port RF cable connection The internal O ring is field replaceable without disassembling the anti rotation clamp Pry it out with fine tweezers or a similar tool when it no longer holds the RF cable securely Insert the new O ring by engaging one side of it in the slot of the phenolic clamp donut Use your fingers to push the O ring into the rest of the slot The HP part number of the O ring is 0900 0007 CD 7 If reshipping is required each test set should be repackaged in the original factory package Containers and materials identical to those used by the factory are available through Hewlett Packard offices Alternatively comparable packaging materials may be used Wrap the test set in heavy paper or anti static plastic If shipping to an HP office or Service Center complete and attach a service tag in the HP 8510 manual set Use sufficient shock absorbing material on all side
86. race and component problems This section also provides information on servicing the front panel test port connectors Other service information is included in the Test Set Troubleshooting section of the this manual Topics covered include checks of the major assemblies and assembly removal procedures among others HP 8514B and 8512A Test Sets Service 7 1 The repair of 3 5 mm RF connectors like those on the rear panels of these test sets is described in the Test Set Troubleshooting section of this manual 7 2 Service HP 8514B and 8512A Test Sets AN HPIB eeccccccccPocccesocccc e909092090000909009900098 5 ATTN ORIVER A15 REGULATOR 23 1 23 1 60900200090000909099926 4 1 00 4 A2 F MUX 23 d SUMMING 1 HP 8514B 8512A Motherboard Figure 7 1 Service 7 3 HP 8514B and 8512A Test Sets 7 4 Service HP 8514B and 8512A Test Sets wy eecccccooc o 5 ATTN DRIVER e e 1 A15 REGULATOR 22
87. rovided with your HP 8510B manual set 3 Clean the mating surfaces with liquid freon or alcohol and lint free swabs Test Set Troubleshooting 5 19 4 Check the pin depth of the gold nose connector The pin depth specification is 0 0000 to 0 0030 inch NOTE If the pin depth is not within specification do not shim Instead install another pin and bead assembly 5 Reconnect the cables disconnected in step 1 using a 5 16 inch torque wrench rated at 56 N cm 5 in Ib 12 Port 1 3 5 mm Connector Port 2 3 5 mm Connector Refer to Figure 5 8 and the following text to replace or repair these 3 5 mm test port connectors torque to torque to 281 304 473 495 Coupler Coupler 25 27 in Ib 42 44 in lb Nut lange 3 5 MM NUT ASSEMBLY TEST PORT CONNECTOR ASSEMBLIES Figure 5 8 Exploded View of the 3 5 mm Port Connector 5 20 Test Set Troubleshooting HP 8514B and 8512A Test Sets Center Pin Repair Procedure NOTE Damaged test port center pins must be repaired by replacing the complete test port connector assembly 1 Remove the test port connector assembly using a 5 8 inch flat wrench 2 Replace with a new test port connector assembly using a 5 8 inch torque wrench to the limits called out in Figure 5 8 3 Check the test port pin depth with a 3 5 mm gauge The center pin recession specificiation is 0 005 to 0 056 mm 0 0002 to 0 002 in 3 5 mm Nut Repair Procedure
88. rt Number Qty Description E32 08513 20018 CENTER CNDCT BHD E33 08513 20018 CENTER CNDCT BHD E34 85040 20015 1 CENTER CONDUCTOR E35 85050 20001 2 CONTACT CTR COND E36 85050 20001 CONTACT CTR COND E37 1250 1466 1 CONNECTOR RF APC 7 HERMAPHR UNMTD 50 OHM E38 5061 5301 5 3 5MM BEAD R AY E39 5061 5301 3 5MM BEAD R AY E40 5061 5301 3 5MM BEAD R AY E41 5061 5301 3 5MM BEAD R AY E42 E43 SEE Figure 6 19 F1 F2 NOT ASSIGNED F3 2110 0043 1 FUSE 1 5A 250V NTD 1 25X 25 UL FL1 0960 0443 1 LINE MODULE FILTERED T1 5180 1233 1 POWER XFMR W1 08513 60121 1 CA AY A12J3 A2J1 W2 NOT ASSIGNED W3 08513 60123 1 CA AY A10J3 A2J4 WA 08513 60124 1 CA AY A11J3 A2J10 W5 08513 60125 1 CA AY A2J2 J11A1 W6 08513 60126 1 CA AY A2J8 J11A4 W7 08513 60127 1 CA AY A2J5 J11A2 W8 08513 60128 1 CA AY A2J11 J11A3 W9 08513 60129 1 CA AY A2J3 J10AI W10 08513 60130 1 CA AY A2J9 J10A4 W11 08513 60131 1 CA AY A2J6 J10A2 W12 08513 60132 1 CA AY A2J12 J10A3 W13 08513 60133 1 CA AY A3J1 A14J1 W14 08513 60134 1 CA AY A3J2 J11A7 W15 08513 60135 1 CA AY A3J3 J10A7 W16 08513 60136 1 CA AY A3J5 J11A5 W17 08513 60137 1 CA AY A3J6 J10A5 W18 08513 60138 1 CA AY A3J7 J11A6 W19 08513 60139 1 CA AY A3J8 J10A6 W20 08513 60140 1 CA AY A3J4 A14J2 W21 W24 NOT ASSIGNED W24 08513 60144 1 CA AY A12J3 J11A1 W25 NOT ASSIGNED W26 08513 60146 1 CA AY A10J3 J11A2 W27 08513 60147 1 CA AY A11J3 J11A3 W28 W30 NOT ASSIGNED W31 08512 20011 1 CA AY A6J3 A10J2 W32 08512 20012 1 CA A8J1 A11
89. s of the test set to provide a thick firm cushion and prevent movement Seal the shipping container securely and mark it FRAGILE In any correspondence with HP refer to the test set by full model number and serial number HP 8514B and 8512A Test Sets 8510 INTERCONNECT 8510 INTERCONNECT TO HP HP 851018 on DISPLAY 8340 4 PROCESSOR USE ONE ONLY RF INPUT FROM SOURCE 10 IF DISPLAY system INTERCONNECT STOP SWEEP BUS ne ee SEEN TEST SET eT INTER ar CONNECT 99 00 96 851028 HP 85148 12R TEST SET 8510 INTERCONNECT FROM HP 8510B 2666 00 9000 Lo 00000 caooo HP 8340 OR 8341 SYNTHESIZED SWEEPER Figure 2 3 HP 8514B and 8512A Test Sets ooon D a oooo mex 99 O IF DETECTOR 8510 INTERCONNECT RF OUTPUT FROM 85108 SWEEP OUT IN HP 83508 SWEEP OSCILLATOR HP 8514B and 8512A System Connections Installation 2 7 2 8 Installation HP 8514B and 8512A Test Sets Operation Introduction This section illustrates the features and functions of the front and rear panels of the HP 8514B and 8512A test sets It also includes an operator s check procedure The function of the operator s check is to confirm that the HP 8514B and HP 8512A test sets function properly as part of an HP 8510 system The performance tests documented in the HP 8510 System Manual and volume 2 of the HP 8510A
90. ses Replacement Part HP Part Number Nut 2950 0132 Lock washer 2190 0104 Bulkhead connector 08513 20017 Pin and bead assembly 3 pieces 5061 5394 Gold nose connector 08513 20016 1 Assembled at the factory not available separately Assemble the bulk head connector lock washer and nut Tighten the nut using the 9 16 in nut driver to 495 N cm 45 in Ib Clean the pin and bead assembly as described in the Microwave Connector Care Manual Insert the pin and bead assembly into the gold nose connector Attach this assembly to the bulkhead connector Torque the bulkhead connector to 281 N cm 25 in Ib Clean the mating surfaces with liquid freon or alcohol and lint free swabs Gauge the pin depth of the gold nose connector Location Pin Depth Specification Front Panel HP 8511A 0 0000 to 0 0017 inch Rear Panel HP 8512A 8513A 8514A 8514B 8515A 0 0000 to 0 003 inch If the pin depth is out of specification do not shim Instead install another pin and bead assembly 5 18 Test Set Troubleshooting 9 Reconnect the cables disconnected in step 1 HP 8514B and 8512A Test Sets 11 Fan WARNING Turn the test set OFF and disconnect the power cord from the mains Electrocution can result if power is not removed from the test set prior to this procedure NOTE To replace the fan transformer T1 must be removed so that the ends of the fan wires may be unsoldered from line module Disassembly 1 Turn the test
91. set Remove the heat sink from the VTO by removing the eight 8 screws that hold it to the VTO Remove the two 2 sampler mounting screws from the opposite ends of the sampler Loosen the nut connecting the VTO to the sampler and remove the sampler Remove the frequency converter 4 from the test set Remove the 2 sampler mounting screws from each sampler The VTO heat sink may need to be removed for access Loosen the nuts connecting the VTO to each sampler disconnect the samplers and remove the VTO assembly Remove the two 2 VTO mounting bracket screws to separate the bracket from the VTO before returning the VTO to HP for repair 7 Regulator Board Assembly Unplug the transformer socket from the regulator board Remove the three 3 mounting screws from the top edge of the regulator board it may be necessary to disconnect some semi rigid cables to ease removal of the screws Remove the regulator board it may be necessary to partially back out one of the transformer mounting screws for clearance 8 Step Attenuator Assembly 5 16 Test Set Troubleshooting Unplug the ribbon cables of the step attenuator to be removed Remove the regulator board 7 to access the ribbon cable sockets if necessary Remove the attenuator mounting bracket screws Remove the attenuator and mounting bracket from the test set Remove the mounting bracket from the attenuator before sending the attenuator to HP for repair HP
92. set on its right hand side 2 Use a 5 16 inch open end wrench to remove the hardline cables connected between couplers A7 A9 and bulkhead connectors J2 and J5 3 Unplug the transformer connector mating with connector J2 on the 15 regulator board assembly 4 Usea large pozi driv screwdriver to remove the four screws and washers holding transformer T1 onto the rear panel 5 Use a large pozi driv screwdriver to remove the one screw holding the transformer angle bracket to the main deck Carefully remove the transformer from the test set and put it on the bench close to the test set The transformer wires soldered to the FL1 line module are short so do not pull on the transformer too much 6 Strip the heat shrink tubing off of the two fan wires and unsolder them from line module FL1 Use wire cutters to cut any cable ties holding the fan wires to nearby cables 7 Useasmall pozi driv screwdriver to remove the screw and lock washer securing the green yellow fan ground wire to the top of the rear panel frame 8 Usea small pozi driv screwdriver to remove the four screws holding fan B1 to the rear panel and remove the fan Assembly 1 Assemble the bulkhead connector lock washer and nut Use the 9 16 HP 8514B and 8512A Test Sets inch nut driver to tighten the nut to approximately 500 N cm 45 in Ib 2 Clean the pin and bead assembly using the procedures described in the Microwave Connector Care Manual HP Part number 08510 90064 p
93. sion 3 5 mm female Impedance 50 ohms nominal Damage input level 23 dBm Damage input level Source power levels for reference channel phase lock Port 1 2423 dBm Port 2 gt 13 dBm Minimum 2 dBm Maximum 12 dBm Nominal operating power level Nominal connector nut size 8 mm Frequency Operating Level 0 045 to 8 GHz 4 dBm Recommended torque 8 to 18 GHz 2 dBm Precision 3 5 mm 90 N cm 8 in Ib Nominal connector nut size 20 mm SMA 56 5 in Ib Recommended torque 90 N cm 8 in Ib 1 Do not exceed 10 dBm input to Port 1 10 dBm input to Port 2 for proper operation Table 4 4 8514B 8512A Power Requirements and Physical Characteristics Operating Temperature 0 C to 55 C Power 110 120 220 or 240 10 Vac 47 to 66 Hz line frequency Dimensions 460 mm X 133 mm X 609 mm 18 1 X 5 25 X 24 inches Weight HP 8514B 17 kg 38 Ib net HP 8512A 15 kg 33 Ib net HP 8514B and 8512A Test Sets Specifications 4 3 Table 4 5 Recommended Equipment Item Critical Specifications Recommended Model Use Network analyzer No substitute HP 8510A B Source Controller No substitute HP 9000 series 200 or 300 with P 1 Mbyte memory Disc drive compatible with controller P Multimeter range 0 to 50V HP 3456A T Oscilloscope 50 MHz bandwidth HP 1740A T 1 O operation P performance test T troubleshooting 2 HP 8340 or 8341 or 8350 with plug in Ref
94. t of each test set The locations of these fuses are also given in the parts list Address Switches Set the switches as indicated in Figure 5 1 dark side of switch is depressed The HP IB address switch is on the test set rear panel The HP IB address switch is easy to access but need not be changed unless HP 8510 bus error messages are visible on the CRT This switch is set to the binary number 20 at the factory Figure 5 1 Default HP IB Switch Setting for All Test Sets 20 Binary HP 8514B and 8512A Test Sets Test Set Troubleshooting 5 3 Test Set Self Test Indicators If the active LED on the front panel does not light within two seconds of turn on or lights immediately the test set has not passed its self test You can determine what part of the self test failed by determining which HP IB LEDs on the A4 assembly are lit The table below shows the possible self test failures A4 HP IB LEDs Self Test Indication Time after turn on LSN TLK SRQ REM PWON ON ON ON ON 0 to 0 5 seconds on briefly Fail ROM Test OFF ON ON ON Pass ROM Test OFF OFF ON ON 0 5 to 2 0 seconds Pass RAM Test OFF OFF OFF ON Pass RAM Test OFF OFF OFF OFF after 2 seconds If Self Test Falls to Run 5 4 Test Set Troubleshooting Two seconds after turn on all four HP IB LEDs should go off and the front panel active LED should light simultaneously After going out briefly the HP IB LEDs will light according to the state of the
95. test set If you are using multiple test sets the first test set in line will be the active test set until another is chosen If the portion of memory which contains the self test programming is faulty the self test will not run properly The following conditions indicate that the self test ROMs are faulty all LEDs flash briefly and go off all LEDs flash briefly and stay on active LED goes on before HP IB LEDs go out HP 8514B and 8512A Test Sets active LED does not go on at all check LED operation before proceeding 1 vss Figure 5 2 Location of Assembly and Configuration Switch Settings Configuration Switch The configuration switch is on the A3 summing amplifier assembly refer to Figure 5 2 It is not easy to access or reset you must remove the top cover a bracket and the A3 assembly Therefore unless one of the following conditions exist don t change it Reasons to suspect these switches are set incorrectly include HP 8510 turn on frequencies are not those of test set HP 8510 allows selection of two port S parameters with a transmission reflection test set HP 8514B and 8512A Test Sets Test Set Troubleshooting 5 5 Check VTO Driver LO There are two procedures provided to check the VTO The first one 1 checks the VTO at two frequencies the second one 2 is more thorough and checks the VTO at 12 frequencies throughout the VTO range 1 Using
96. tions of Major Assemblies 6 10 Replaceable Parts HP 8514B and 8512A Test Sets 051 2 places 2 places 2 places 2 places Q E33 E37 DS2 34 8 J14 P O A6 F1 F2 iir See Figure fa ee Figure 6 8 6 2 places 3 places 7 places 4 places E18 E23 J2 E19 E24 23 E20 E25 J4 E21 J5 E26 A2081 212 P O A20 E27 E22 J7 J8 4 places G 4 places 4 places 2 places 2 places 2 places Not Visible Figure 6 2 HP 8514B Miscellaneous Mechanical Chassis and Electrical Parts HP 8514B and 8512A Test Sets Replaceable Parts 6 11 LEFT SIDE 8 places 16 places shown 2 places 2 places RIGHT SIDE 3 used 55 places Figure 6 3 HP 8514B Miscellaneous Mechanical Chassis and Electrical Parts 6 12 Replaceable Parts HP 8514B and 8512A Test Sets 6 places 4 places 37 places 18 8 places 8 places e 9 6 places Not Visible Figure 6 4 HP 8514B Miscellaneous Mechanical Chassis and Electrical Parts HP 8514B and 8512A Test Sets Replaceable Parts 6 13 WAS3 W33 Long Long 4 places or or W68 W67 Shot W60 E39 E48 4 places Not Visible Figure 6 5 8514B Miscellaneous Mechanical Chassis and Electrical Parts 6 14 Replaceable Parts HP 8514B and 8512A Test Sets E ag 7 E5 ay 5places Eog 90 E3277 0 E31 wes sj W
97. ts in the Service Program section to verify the 20 MHz output If one or more but not all channels look bad troubleshoot the HP 85102 by referring to the Service Program and Block Diagrams sections of the Service Manual Then recheck the unratioed channel power levels Single channel problems suggest the IF Mixer board corresponding to the User function channel al b1 b2 or a2 is faulty Refer to the Overall System Block diagram located in the Block Diagrams section of the Service Manual Multiple channel problems indicate the problem is most likely in the circuitry after the IF Mixer boards for example the IF amplifiers or synchronous detectors Refer to the HP 85102A Overall Block Diagram in the Block Diagrams section of the Service Manual Determine whether the failure is in the reference path or the test path Test the suspect board s using the procedures provided in the Service Program section Check the IF Amplifiers and Synchronous Detectors by swapping the reference and test board assemblies since they are identical and seeing if the problem moves Test Set Troubleshooting 5 37 5 38 Test Set Troubleshooting HP 8514B and 8512A Test Sets Replaceable Parts Introduction This section contains information for ordering parts Exchange Assemblies Available describes how to order assemblies which are available on an exchange basis HP 8514B replaceable parts are identified by Table 6 1 and Figure 6 1 through F
98. vides the same 20 MHz signal to the HP 85102B as the test set and source Thus it indicates whether the problem is in the IF detector HP 85102B service adapter provided in the HP 8510 Service Manual refer to Service Tools BNC to BNC cable TEST SET HP 85102 27 a 7 SERVICE ADAPTER IF MULTIPLEXER HP 85102 Signal Path with Service Adapter Service Adapter Procedure 5 36 Test Set Troubleshooting 1 Connect the HP 85102B service adapter to the HP 85102B rear panel 20 MHz OUT connector and the J2 IF DISPLAY INTERCONNECT connector 2 Press PRESET MARKER STIMULUS MENU STEP PARAMETER MENU and each User softkey to observe the unratioed power level of Userl through User4 channels The traces should be flat lines quite close to each other as indicated by the marker value typically about 28 5 dB HP 8514B and 8512A Test Sets Service Adapter Conclusions HP 8514B and 8512A Test Sets If all of the channels look good with the service adapter and all looked bad in the unratioed power test the HP 85101 and 85102 are working The problem is probably source related Refer to the Source Tests and Service Program sections of the Service Manual to continue troubleshooting the problem If all four User channels look bad with the service adapter suspect the 20 MHz signal from the A6 clock board assembly Refer to the paragraph titled HP 85102 IF Detector Tes
99. y bias through the center conductor of Port 2 to active devices under test Operation 3 5 Operator s Check Equipment Procedure 3 6 Operation 19 Port 1 Bias HP 8514B only This female BNC connector is used to supply bias through the center conductor of Port 1 to active devices under test Passing this check confirms that the HP 8514B and HP 8512A test sets function properly as part of an HP 8510 system Item HP Model or Part Number Network analyzer system HP 8510A B Test port return cable set HP 85131D Test port return cable HP 85131C 10 dB pad attenuator HP 8493C option 010 1 Use with HP 8514B 2 Use with HP 8512A Plug in and turn on the test set it should not be connected to any other instrument or device now The line LED should light immediately and the active LED should light in about two seconds Those indications mean that the instrument has passed its self test Turn off the test set and connect it to the HP 8510 system as shown in Figure 2 3 on page 2 7 Turn on all of the system instruments network analyzer last Let the instruments complete their self tests Remove any cables or DUTS from the test set test ports Press PRESET STIMULUS MENU on the HP 85102 to preset the HP 8510 and access the STIMULUS menu 1 HP 8340 41 systems press STEP on the HP 85101 to put the source in step mode b 8350B systems press SWEEPTIME 2 0 0 k m to set the sweep time to 200 ms In