Home
Health Buddy 3 Field Service Manual
Contents
1. e Labels on the bottom and back are not legible or intact e Onthe LCD screen o Scratches fogging or other defects that would hinder the user from reading the screen o Cracks in the glass o Film delamination on the glass e On the plastic casing and connector ports on the back o Cracks abrasions or discolorations o Stains that cannot be removed with a dampened cotton cloth AC power supply and converter plugs Reject the power supply if you see any of the following defects e Text or symbols are not legible e Casing has cracks scratches abrasions or indentations e Connector blades and plugs are not intact e Cordis badly twisted or has knots cuts abrasions or discoloration If the power supply and converter plugs pass the visual inspection test the power supply with a functioning Health Buddy Reject the power supply if the Health Buddy does not start up and display the logo screen Telephone cord Reject the telephone cord if you see any of the following defects e Cord is twisted or has knots cuts abrasions or discoloration e Connectors have missing tang or 4 pins are not intact Ethernet cable Reject the Ethernet cable if you see any of the following defects e Cable is twisted or has knots cuts abrasions or discoloration e Connectors have missing tang or 8 pins are not intact 6 Testing the Health Buddy Before you can transfer a Health Buddy to another patient you need to verify that it works properly To test
2. Health Buddy 2 Plug the HB3 Utility Key into a USB port on the back of the Health Buddy If you do not have an HB3 Utility Key see Creating a Health Buddy 3 Utility Key 3 When the Health Buddy prompts you to select a utility to run select Update ROM and then follow the instructions on the Health Buddy The Health Buddy will tell you if the Update ROM program is successfully completed The text in the picture below might not exactly match what you see The term firmware means the same as ROM SERIES Henn BOSCH Please select a utility to run 1 Clear Data 52983 2 Firmware Update 57009 4 When the ROM Update program is completed unplug the Health Buddy from the power supply and remove the HB3 Utility Key from the Health Buddy The ROM of the Health Buddy is now updated to the latest version 10 Packaging the Health Buddy When the Health Buddy is ready to be transferred to a new patient package it in preparation for shipping Note The following photos show the United States version of the Health Buddy packaging The European version might look slightly different To package the Health Buddy 1 Assemble the packaging carton 2 Health Buddy Appliance Model Health Buddy 3 CE REF 096 0716 001 RORE A A m al Math Hero Matec ine EOMER mad vride one A J Pan Ata CA 4301 Sch Mgraben di D 30178 Hannavar Germany Ww ae LL Ax LLL EI L a TY Pon dei um mica 5 Ir MENE an spe
3. of any field service work that is done by the customer Before you do any field service work observe the following restrictions e Do not open the plastic casing of the Health Buddy appliance Opening the plastic casing of a Health Buddy appliance voids any and all warranties e Do not immerse the Health Buddy appliance in liquid e Do not modify the label on the Health Buddy appliance in any way Providing feedback on this document If you have suggestions or feedback on this document you can send an email to doc feedback us bosch com A response will not be provided unless you request one 2 Health Buddy part identification and part list Front of the Health Buddy appliance Indicator m Light a Ewa Screen Speaker M Ambient Light Sensor o 960165 e DR Buttons 4 Infrared Port Back of the Health Buddy appliance Power Supply Connector Telephone Jack USB Ports 3 RJ11C Connectors 2 Ethernet Port Health Buddy components Ethernet Cable Power Supply UK option Note Component diagrams are for reference only Health Buddy 3 part list Part Part Number for Health Part Number for Health Buddy Model 096 1000 001 Buddy Model F 03D 200 035 Health Buddy Appliance 096 1000 001 F 03D 200 035 US Power Supply F 03D 200 024 F 03D 600 440 Converter Plug for United Kingdom Converter Plug for Europe Telephone cord shielded RJ11 connectors Telephone cord with ferrite bead unshielde
4. Health Buddy 3 Field Service Manual BOSCH Ex 2070 Medtronic v Bosch IPR2014 00488 Table of Contents la IONOOUCUON e cH RnB 3 2 Health Buddy part identification and part list eeeseseeseeeeeeeeeeeeeeeeene 4 3 Retrieving the Health Buddy an oaan eneen enenen venen ennen nnerenen venen nnns 5 4 Cleaning and disinfecting the Health Buddy nennen eenen ennrrenenennn 6 5 INSpecting tne Health BUGGY meren tedere a Seed bonitos 7 6 Testing the Health BUGGY znne Seco hac ora en en a adt pto one oae pe beni b hn idt tni 8 7 Creating a Health Buddy 3 Utility Key oanenennenenen eenen ennr venen eenennnn 9 8 Clearing patient data from the Health Buddy aaneen nenn nenne nennen 10 9 Updating the Health Buddy ROM ananas enennerenenennenenenvenen ener ennerens 11 10 Packaging the Health Buddy oane oenn ereen venen ennerenen venen enenensevenenennn 12 11 Storing and shipping the Health Buddy aaan onee en venen vennen venen vennen 16 1 Introduction Health Buddy appliances that are in good condition and that are no longer needed by disenrolled patients can be reused by other patients who are starting a Health Buddy program This field service manual describes the procedures for transferring Health Buddy 3 appliances to other patients It is intended for customers of Robert Bosch Healthcare However Robert Bosch Healthcare does not warranty the results
5. d RJ11 connectors Polybag 740 01 10 001 F 03D 600 446 Silica Gel Pak 740 01 12 001 F 03D 600 447 For some older Health Buddy units the Power Supply part number is F 03D 600 440 and the Telephone Cord part number is F 03D 600 425 Please ask when ordering 3 Retrieving the Health Buddy Health Buddy appliances that are no longer needed by disenrolled patients should be retrieved from the patient Then you can determine if it can be reused by other patients who are starting a Health Buddy program Retrieve the following Health Buddy 3 components from the patient e Health Buddy Appliance e US Power Supply e Telephone Cords e Ethernet Cable All paper products including shipping cartons and Instructions for Use Manuals are considered to be fomites contaminated objects and should be discarded and never reissued to patients or clients To replace missing components call Robert Bosch Healthcare support 4 Cleaning and disinfecting the Health Buddy Always clean and disinfect the Health Buddy appliance and components that you retrieve from a patient before you do any other service procedures with it Materials and equipment e Hand wash soap e Clean disposable medical gloves e Face shield or safety goggles e Lab coat or protective smock e Super Sani Cloth Germicidal Disposable Wipe Manufacturer PDI Professional Disposables Inc P N Q55172 Phone 1 800 999 6423 e Glass cleaner wipes or solution e Soft cleaning wip
6. es or paper towels e Clean clear high density plastic bags with twist ties or secured closure e Other safety equipment as per applicable Occupational Safety and Health Administration OSHA requirements Safety precautions e Ensure that your work area is well ventilated e Unplug the Health Buddy appliance before you begin e Follow the guidelines for hand washing the use of protective attire and other guidelines recommended by Standards and Recommended Practice Safe Handling and Biological Decontamination of Reusable Medical Devices in Health Care Facilities and in Nonclinical Settings ANSI AAMI ST35 2003 e Follow all applicable OSHA regulations e Follow all instructions and safety precautions on cleaning product labels e Wear protective equipment such as gloves goggles lab coat Health Buddy restrictions e Do not use harsh or caustic chemicals or abrasive products to clean the Health Buddy appliance Use only Super Sani Cloth Germicidal Disposable Wipes e Do not immerse the Health Buddy in any liquids e Do not spray cleaning solution directly on the Health Buddy appliance Avoid soaking open areas in and around buttons and openings Procedure To clean and disinfect the Health Buddy 1 Wash your hands 2 Apply clean medical gloves 3 Using as many Super Sani Cloths as needed clean and disinfect the entire surface area of the Health Buddy the cords and the power supply Clean and disinfect the display sc
7. lity Key a USB flash drive that contains the HB3 Utility Key software on it you need to create one See Creating a Health Buddy 3 Utility Key Procedure To clear the previous patient s PHI from a Health Buddy 1 Power up the Health Buddy by plugging one end of the power supply into an electrical outlet and the other end into the back of the Health Buddy 2 Plug the HB3 Utility Key into a USB port on the back of the Health Buddy The Health Buddy screen might change color and take a full minute before displaying a menu 3 When the Health Buddy prompts you to select a utility program to run select Clear Data and then follow the instructions on the Health Buddy The Health Buddy will tell you if the Clear Data program is successfully completed The text in the picture below might not exactly match what you see i TEE er BOSCH Please select a utility to run 1 Clear Data 57983 2 Firmware Update 5 4 When the Clear Data program is completed unplug the Health Buddy from the power supply and remove the HB3 Utility Key from the Health Buddy The previous patient s PHI is now cleared from the Health Buddy 9 Updating the Health Buddy ROM Before you transfer a Health Buddy to a new patient ensure that the Health Buddy ROM is updated to the latest version Before you begin Check if the Health Buddy firmware needs to be updated 1 Find out what the latest ROM Update version number is by checking the Robert Bosch Heal
8. m eek e ECE A T T 0000 486E poc 1380 3 Place the foam packaging insert in the box The rectangular opening for the power supply should be adjacent to the diagram on the box lid 4 Place the power supply in the rectangular opening and place the telephone cord and Ethernet cable in the smaller rectangular slot 5 Place the Instructions for Use Manual IFU in the slot between the foam packaging insert and the side of the packaging carton that is adjacent to the diagram The front cover of the IFU should be facing the foam packaging insert 6 Place the Health Buddy appliance and one silica gel pak in a polybag pull the polybag tight around the front of the appliance and then place the appliance face up in the packaging insert 7 Close the side of the packaging carton that has the hole that matches the shape of the Health Buddy appliance 8 Close the other side of the packaging carton ensuring that the handle can be grasped through the slot made for it in the packaging carton 11 Storing and shipping the Health Buddy Store the Health Buddy in a cool dry location Keep the Health Buddy out of direct sunlight and away from heat Ship the Health Buddy only in the packaging carton and in accordance with the instructions provided in this document
9. reen gently to avoid scratching it 4 Set aside the cleaned product for 10 minutes to fully air dry to kill the microorganisms 5 Dispose of the Super Sani Cloths in biohazard receptacles in accordance with local policies 6 If you see evidence of insect infestation in the Health Buddy place the Health Buddy in a clear high density airtight plastic bag or container for 30 days and record the day and time in and the day and time out After 30 days clean the unit as defined in steps 3 5 above 7 Remove your gloves 8 Wash your hands References ANSI AAMI ST35 2003 Safe Handling and Biological Decontamination of Reusable Medical Devices in Health Care Facilities and In Nonclinical Settings 21 CFR 820 Medical Devices Current Good Manufacturing Practice CGMP CAN ISO 13485 Section 7 5 5 Medical Devices Quality Management Systems CMDR Sections 14 21 29 CFR 1910 1030 subpart Z Occupational Safety and Health Administration OSHA of the U S Department of Labor Public Health Notification from FDA CDC EPA and OSHA Avoiding Hazards with Using Cleaners and Disinfectants on Electronic Medical Equipment October 31 2007 5 Inspecting the Health Buddy The Health Buddy appliance and components must be inspected to determine whether they can be reused To replace defective components call Robert Bosch Healthcare support Health Buddy appliance Reject the Health Buddy appliance if you see any of the following defects
10. th Buddy 3 HB3 Utility Key is a USB flash drive that contains the HB3 Utility Key software on it If you do not have an HB3 Utility Key you need to create one so that you can clear the patient data and update the firmware on Health Buddy appliances You can also purchase HB3 Utility Keys by contacting Robert Bosch Healthcare Customer Support To create an HB3 Utility Key 1 Obtain a new USB flash drive If you prefer to reuse an old one it must contain at least 50 MB of space 2 Goto the Robert Bosch Healthcare website for your region e Germany http www bosch telemedizin de e United Kingdom http www bosch telehealth co uk e United States http www bosch telehealth com 3 Click Downloads and then click Health Buddy 3 Utility Key 4 Follow the instructions on the web page to download and install both the HB3 ROM Update software and the HB3 Universal Clear Data Key software to your USB flash drive If you need more guidance you can download the Utility Key Manual that is provided on the web page You now have an HB3 Utility Key that you can use to clear patient data and update the ROM on Health Buddy appliances 8 Clearing patient data from the Health Buddy All protected health information PHI from the previous patient that is stored on the Health Buddy appliance must be erased cleared before the Health Buddy can be transferred to another patient Before you begin If you do not have an HB3 Uti
11. thcare website a Goto the Robert Bosch Healthcare website for your region e Germany http www bosch telemedizin de e United Kingdom http www bosch telehealth co uk e United States http www bosch telehealth com b Click Downloads click Health Buddy 3 Utility Key and then click HB3 ROM Update Utility Installer Page 2 Power up the Health Buddy by plugging one end of the power supply into an electrical outlet and the other end into the back of the Health Buddy After displaying the logo screen the Health Buddy will display the message Your Health Buddy has experienced an interruption in power 3 Goto the welcome screen by pressing continue 4 Goto the first technical screen by pressing the third button which is not labeled and then read the build number i 5 4 Health BOSCH This information is for Bosch technical staff 21 2011 124954 Build 58789 PFX PI 0 RBMR TR HW Rev 3 C Serial 00001380485E NCT Sep 22 2011 01 58 40 ETH 5 If the build number on the Health Buddy technical screen matches the version number of the ROM Update that is listed on the web page the Health Buddy is up to date If those numbers do not match the ROM on the Health Buddy is not up to date and you will need to update it Procedure To update the ROM of the Health Buddy 1 Power up the Health Buddy by plugging one end of the power supply into an electrical outlet and the other end into the back of the
12. the Health Buddy 1 Power up the Health Buddy by plugging one end of the power supply into an electrical outlet and the other end into the back of the Health Buddy After displaying the logo screen the Health Buddy will display the message Your Health Buddy has experienced an interruption in power 2 Goto the welcome screen by pressing continue 3 Press settings and cycle through the screens while observing the screen for defects i HB e BOSCH Welcome BOSCH a If nothing is displayed on the screen press any button for at least 5 seconds to activate the Health Buddy If the screen still does not activate substitute a different functioning power supply and repeat the test If the defect is still not resolved the Health Buddy cannot be serviced and must be rejected b If the text on the screen is not clear or if unusual dots or lines appear on the screen substitute a different functioning power supply and repeat the test If the defect is not resolved the Health Buddy cannot be serviced and must be rejected c If the brightness of the screen is very low or if the screen flickers repeatedly substitute a different functioning power supply and repeat the test If the defect is not resolved the Health Buddy cannot be serviced and must be rejected d If you find no defects the Health Buddy can be reused 4 Disconnect the power supply from the Health Buddy 7 Creating a Health Buddy 3 Utility Key A Heal
Download Pdf Manuals
Related Search
Related Contents
HT-4 6 " 一日 ------- -ー屋内形 ~※一日は 弟 (日し)認定品です。 MANULE UTENTE OfficeSuite s60 Digiplex Evo : EVO048 et EVO192 V2.1 Guide de programmation Copyright © All rights reserved.
Failed to retrieve file