Home
Manual - SR Instruments, Inc.
Contents
1. SYSTEM DESCRIPTION and INTENDED USE SYSTEM DESCRIPTION The SR725i SR725i L Wheelchair Scale employs the latest in microprocessor and load cell technology to provide accurate and repeatable weight data Four 4 identically matched transducers are strategically placed to ensure an accurate representation of the patient s weight The low power microprocessor circuitry allows the SR725i7 SR725i L to derive its power from six 6 common D cell batteries which will provide up to 400 hours of weight readings before needing replacement This eliminates the need for an external battery charger or the danger of an AC power supply cord on a portable scale The patient s weight is displayed on a 16 character dot matrix LCD The weight data may be viewed in either pounds or kilograms with a displayed resolution of 0 1 for each INTENDED USE The SR7251 SR725i L Wheelchair Scale is specifically designed for use as a portable patient WARNING weighing system for ambulatory and non ambulatory DO NOT EXCEED wheelchair bound patients Maximum weight capacity MAXIMUM WEIGHT LIMIT OF must not exceed 1000 pounds or 454 kilograms gross 1000 LB 454 KG weight MAINTENANCE and CLEANING The display case for the SR725i SR725i L Wheelchair Scale is made of a powder coated aluminum Exercise WARNING caution when cleaning the display window as it is made DO NOT use pressurized water or of clear polyester and can be scratched by abrasive
2. PRINTER MOUNTING COLLAR amp HARDWARE PRINTER MOUNTING BRACKET amp HARDWARE PRINTER PAPER LOCTITE SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 4 of 22 PACKING CHECKLIST Model SR7257 L Wheelchair Scale System nei EE SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN725i_ 140807 Page 5 of 22 ASSEMBLY STEP 1 Unpack the scale and check parts against the PACKING CHECKLIST If there are any missing or damaged parts please call the Service Hotline at 1 800 654 6360 STEP 2 Verify that the serial number on the Display Unit 1 matches that on the Base Assembly 3 Figure 1 Scale System Diagram PARTNAME 4 Mast Locking Lever ube Te optional 9 Printer Cable optiona Figure 2 Parts Identification List STEP 3 Figure 1 Lay the Base Assembly 3 with the attached Mast 2 on the floor STEP 4 Loosen the Mast Locking Lever 4 to unlock the Mast Pull the Mast up and away from the scale and swing it up until the Mast is perpendicula
3. Steam The scale system contains cleaners Mild soap and water is recommended for microprocessor circuitry and strain general cleaning and disinfecting gauge sensors that may be adversely affected by exposure to such an environment SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN725i_ 140807 Page 9 of 22 STORAGE and TRANSPORTATION STORAGE If storing this equipment for periods longer than three 3 months remove the batteries To maintain proper operation of this instrumentation storage and transport conditions should not vary outside the following conditions Relative Humidity 0 to 85 Ambient Temperature 14 F to 122 F 10 C to 50 C TRANSPORTATION To transport the scale unlock Mast Locking Lever Figure 6 Fold Mast Pipe Assembly down into the scale platform assembly Lock the Mast Locking Lever to secure the Mast Pipe Assembly in position Hold the Mast Pipe Assembly close to platform assembly and roll the scale to the new location See ASSEMBLY for detailed instructions to re assemble the scale system When placing the scale system in the new location care should be taken not to shock the unit Lift the scale up and onto the Transport Wheels Figure 6 Mast Locking Lever SR Instr
4. Collar to the Mast NOTE The three 3 holes on the Printer Mounting Collar should be towards the top of the Mast facing the same direction as the scale display readout Figure 4 STEP 4 Apply a small amount of Loctite to the two 2 small screws provided and attach the Printer Mounting Bracket 12 to the Printer Mounting Collar figure 5 STEP 5 Attach the Printer to the Printer Mounting Bracket by inserting the tabs on the Printer Mounting Bracket 12 into the slots on the back of the Printer and carefully snap in place STEP 6 After the Display Unit 1 1s installed plug the Printer Cable plug 9 into the Printer and into the connector on the bottom of the Display Unit tighten Printer Cable screws I SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 7 of 22 Figure 4 Printer Mounting Collar ASSEMBLY Cont d Figure 5 Printer Mounting Bracket REPLACEMENT PARTS and ACCESSORIES SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 8 of 22
5. display board Figure 11 CALIBRATION will flash on the display Figure 11 Display Board Calibration Switch Location STEP 2 Select two 2 known calibrated weights traceable to NIST NOTE The first weight should be at least 500 pounds half of the maximum scale capacity The second weight should be less than half of the first weight DO NOT USE barbells or uncalibrated weights STEP 3 Press the MENU button until FULL 1000 00 Lb is displayed Set the FULL value of the first selected calibrated weight Use the UP arrow button to select the digit and the DOWN arrow button to change digit Press ENTER to save changes STEP 4 Press the MENU button until HALF 500 00 Lb is displayed Set the HALF value of the second selected calibrated weight Use the UP arrow button to select the digit and the DOWN arrow button to change the digit Press ENTER to save changes STEP 5 Press MENU button until 3 Pt Calibration is displayed Press the UP arrow button STEP 6 Zero the scale by removing all weight from the platform Press the UP arrow button STEP 7 Place the HALF weight from Step 4 on platform Allow weight to stabilize Press UP arrow to save change Remove weight Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Opera
6. is units lb or kg in or cm uu is LB or KG E is end of packet SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 19 of 22 TROUBLESHOOTING SYMPTOM REASON CORRECTIVE ACTION Press the WEIGH button or remove one battery The characters only appear on half of the wait five seconds then re install the battery and try display the WEIGH button again The display lights appear to work but do Check to ensure the membrane switch label is correctly not respond to button activation plugged into display board Check to ensure the calibration switch is not in the Calibration Mode Figure 13 The display shows no reading at all Check to ensure batteries are installed correctly see directions for BATTERY REPLACEMENT Check display cable to make sure it is connected securely The display feels loose when raising or Remove the black plastic plug located below the lowering display rotation assembly Insert a 5 32 Allen Key and slightly tighten the tensioning screw until the mast feels tight again For additional information or assistance telephone our Service Hotline 1 800 654 6360 or e mail sri srinstruments com SR Instruments Inc 600 Young Street Tonawan
7. mode or the slope and change in slope is calculated from three points zero half and full scale in the 3 point calibration mode SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 16 of 22 CALIBRATION NOTE Ensure that nothing is in contact with the scale system during this procedure Remove hands from the system when noting the displayed calibration results CHECKING CALIBRATION STEP 1 Select two 2 known calibrated weights traceable to NIST NOTE The first weight should be at least 500 pounds half of the maximum scale capacity The second weight should be less than half of the first weight DO NOT USE barbells or un calibrated weights STEP 2 Zero the scale by pressing and holding ZERO WEIGH button STEP 3 Place the first calibrated weight on the scale Wait for scale to stabilize note scale reading Remove weight STEP 4 Place second calibrated weight on scale Wait for scale to stabilize note scale reading Remove weight STEP 5 The scale readings for both weights should be within the Calibration Tolerance Figure 9 CALIBRATION TOLERANCE TABLE LOW APPLIED HIGH LIMIT LOAD LIMIT 99 9 100 0 100 1 199 8 200 0 200 300 0 400 0 500 0 600 0 700
8. nes aeciaeaceteb see Onn DK Ao a araa E RaRa N araroa 19 WARRANT EE 20 NOTES a E 21 TABLE OF FIGURES nee 1 Scale System Dias ram oerrinne EE 5 Figure 2 Parts Identiiication List scsccsciescassisccssssasecearssnnersvovedcansbaccataassacasunskestaseouedearenicensasecsseannence 5 PIQUE o Dipa BE 6 Figure 4 Printer Mounting Eege 7 PISuUre 5 Printer Mounting PACK CL sissiscscaxiseressonsacensssnsvcnsvaccnsannsedacsssoaseunssusacnssvavenssvnseiasssasasseneaes 7 RTR EC MOCKING MCV E 9 VUES Zeta 11 Figure 8 Battery Compartment Panel Screw ssssssssssssssssssssssssssssssssssssssssssssssssssssssssssees 14 Figure 9 Calibration Tolerance Table egeeesegeseeg eet geess 16 Figure 10 Calibration Switch Tetange dee 16 Figure 11 Display Board Calibration Switch Location ccccccccscssssssssssssssssssssscssscccccssssssees 17 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 3 of 22 PACKING CHECKLIST Model SR725i Wheelchair Scale System DESCRIPTION QUANTITY Box 1 SCALE ASSEMBLY 32 in x 30 in 81 cm x 76 cm PACKAGE OF SIX 6 D CELL BATTERIES CALIBRATION CERTIFICATE WARRANTY CARD MANUAL Box 2 Optional Printer Kit PRINTER PRINTER BATTERY CHARGER PRINTER CABLE
9. 0 800 0 900 0 1000 0 1001 0 Figure 9 Calibration Tolerance Table IMPORTANT CALIBRATION Qualified service personnel only should perform this procedure The SR725i SR7251 L load cells have no user serviceable components and should not be tampered with for any reason Re calibration is generally not required but should be verified periodically to ensure accuracy The recommendation for calibration check is at least once every 12 months or as individual maintenance policy requires CALIBRATION SWITCH ae Figure 10 Calibration Switch Diagram Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR7257 Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 17 of 22 CALIBRATION con t CAUTION The integrated circuits and semiconductors on the printed circuit boards may be damaged by electrostatic discharge ESD Be sure to use proper handling precautions at all times SETTING CALIBRATION NOTE Ensure that nothing is in contact with the scale system during this procedure Remove hands from the system when noting the displayed calibration results STEP 1 Remove the three 3 screws on the left side cover of the display housing Put the scale system into the Calibration Mode by switching the calibration switch 14 on the
10. 0 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 21 of 22 NOTES SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 22 of 22 SR Scales By SRInstruments Inc Precision amp Technology in Perfect Balance SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc
11. 2 CALCULATING BMI Press to calculate BMI When the BMI button is pressed the default starting value is set either to 65 in or to 165 cm example HT 65 in Use the UP or DOWN arrows to adjust the default height to the value of the patient s height NOTE To calculate the BMI a patient s stable weight needs be stored as indicated in WEIGHING above if no stable weight has not been stored NO WEIGHT DATA will be displayed and the display will then go back to the weigh screen WT 0 0 Lb Press ENTER to save height data and display BMI calculation The BMI will be displayed example BMI 20 5 RECALLING LAST STABLE WEIGHT gt RECALL Press to recall last stable weight The display will scroll thru WT HT and BMI stored values in approximately two second intervals example RCL WT 123 5 Lb RCL HT 65 in and RCL BMI 20 5 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 14 of 22 BATTERY REPLACEMENT WARNING DO NOT REMOVE BATTERIES WHILE SCALE IS ON ALLOW SCALE TO SHUT DOWN NATURALLY THRU TIMING OUT THIS PREVENTS POSSIBLE VOLTAGE DRAIN ON THE PRINTED CIRCUIT BOARD COIN BATTERY STEP 1 The display w
12. Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN725i_ 140807 Page 1 of 22 Sec ko by SR Instruments Inc Wheelchair Scale SR725i SR725i L Operating and Service Manual Serial Numbers 6000 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SRInstruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 2 of 22 TABLE OF CONTENTS TABLE OF TG CIR E 2 PACKING CHECKLIST MODEL SR7 291 iresi aaia 3 PACKING CHECKLIST MODEL SR egene 4 PRS AY IS E E 5 REPLACEMENT PARTS AND ACCESSORIES Sa eseeeeeeeeeeeeeeeeeeeeeeEeEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEee 7 SYSTEM DESCRIPTION AND INTENDED USE cccssssssssssssssssssssssssssssesssesessseccseseeees 8 MAINTENANCE AND CLEANING ee 8 STORAGE AND TRANSPORTATION svi cccassssssicctesesecievsostcasssecacsssssaiseieracastevenrscesveriersasssaissicianess 9 SFECIFICA TITON KE 10 COON CIN TIONS cinan a A E a a 11 BASIC SYS LEWE OPERA LION EE 12 BAT TERY RKREFLACEMEN RN EE 14 THEORY OF OPEKA TION sisscehenscotetescncesivectitelesciece desea eE E e EE e E Naai 15 CALIBRATION cre E E E E E 16 CONFIGURING SEND BUTTON eiiscsesscessrenteansssacsanirestsbescasusasatenteanssacusandventeasscesusasavantesssecdsanives 18 TROUBLESHOOTING gsr a ca aes ec asec a ceses stents sean aces
13. TING SYSTEM ZERO Make sure the scale is free and clear of any obstructions and press and hold the ZERO WEIGH button The displayed message will indicate HOLD TO ZERO and count iy down to zero Make sure that nothing is in contact with the scale while zeroing the system In a few seconds the display will read WT 0 0 Lb or Kg This action also resets previously stored weight height and BMI values to zero WEIGHING Ke Press the ZERO WEIGH button Position the patient on the scale Lock the patient s 0 wheelchair brake to prevent movement The weight stable indicator lf flashes on the display When the weight is stable the weight stable indicator remains solid The display will indicate the patient s weight in either pounds or kilograms example WT 123 5 Lb The stable weight is auto stored in memory NOTE If patient will be using a cane for support on the scale place the cane on the scale while zeroing the system This will ensure that the patient s NET weight will be displayed It is recommended that the system be zeroed prior to each new patient CAUTION DO NOT LEAVE PATIENT UNATTENDED ON THE SCALE PLATFORM SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 13 of 2
14. da NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 20 of 22 WARRANTY FOUR YEAR LIMITED WARRANTY Each SR Instruments Inc is manufactured with high quality components SR Instruments Inc warrants that all new equipment will be free from defects in material or workmanship under normal use and service for a period of four 4 years from the date of purchase by the original purchaser Normal wear and tear injury by natural forces user neglect and purposeful destruction are not covered by this warranty Warranty service must be performed by the factory or an authorized repair station Service provided on equipment returned to the factory or authorized repair station includes labor to replace defective parts Goods returned must be shipped with transportation and or broker charges prepaid SR Instruments Inc s obligation is limited to replacement of parts that have been so returned and are disclosed to SR Instruments Inc s satisfaction to be defective The provisions of this warranty clause are in lieu of all other warranties expressed or implied and of all other obligations or liabilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with
15. ill read REPLACE BATTERY STEP 2 Figure 8 Unscrew the panel screw on the Battery Compartment Cover 13 and remove the battery compartment cover STEP 3 Remove and replace ALL six 6 D cell batteries Refer to diagram in the battery compartment for placement STEP 4 Press the WEIGH button to confirm display is working STEP 5 Secure the battery cover using the panel screw STEP 6 Zero the system a E SL Bese P 28 d Figure 8 Battery Compartment Panel Screw SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 15 of 22 THEORY OF OPERATION SR Instruments patient weighing systems are digital scales Strain gauge force cells convert the force of an applied weight into an analog signal This signal is amplified by an operational amplifier and converted to a digital signal by an on chip analog to digital converter The digital signal is filtered converted to appropriate units and displayed on the liquid crystal display Strain gauge force cells each contain four strain gauges mounted in a full Wheatstone bridge configuration These bridges convert the physical movement of the force cell due to the applied mass on the system into minute changes in electrica
16. l resistance These changes in resistance produce a voltage difference across the Wheatstone bridge which is amplified by the operational amplifier The amplifier is configured to current sum the output of each cell with potentiometers serving to normalize the sensitivity voltage out per unit of weight applied of each bridge The offset potentiometer produces a small current which nulls the output of the amplifier for an unloaded system The output of the operational amplifier is digitized by the analog to digital converter The sigma delta converter sums a rapid sequence of O s O volts and 1 s reference voltage to achieve balance with the input signal from the amplifier The micro controller filters the digital output of the analog to digital converter subtracts the value saved during the system zero operation and scales the filtered output and then displays the result on the liquid crystal display The micro controller performs a moving median filter of data for continuous weigh and for AutoHold the micro controller performs checks for signal stability before locking in on the reading If the data variance is greater than 0 1 in the AutoHold mode the micro controller will reset the filter and start a new filtering period The micro controller can be placed in a calibration mode where the system can be re calibrated In the calibration mode the system slope is calculated from two points zero and full scale in the 2 point calibration
17. nd increments Press ENTER to save changes Setting TIME and DATE Use the UP arrow button to select digit To change digit use the DOWN arrow button Press ENTER to save changes NOTE When selected the year position defaults to 00 Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SRInstruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 12 of 22 BUTTON FUNCTIONS cont d ENTER Press to save height data and display BMI calculation Stable weight height and BMI values are stored in memory until next stable weight is stored or until system is zeroed BMI Press to calculate the BMI When the BMP is pressed the default starting value HT 65 in or HT 165 cm is displayed If there is no stored stable weight the display will indicate NO WEIGHT DATA and then go back to the weigh screen WT 0 0 Lb UP uP Press UP to adjust height up from the default to increase the scale s on time or to A selecta digit when setting time and date SELECT Z 9 GG bown Press DOWN to adjust the height down from the default to decrease the scale s on time or to change the value of a selected digit when setting time and date CHA Di mmi BASIC SYSTEM OPERATION SET
18. r to the platform Engage Lever to lock the Mast in position NOTE If an optional printer has been ordered go to Page 6 INSTALLING OPTIONAL PRINTER before proceeding SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR7257 Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 6 of 22 ASSEMBLY Cont d eem 5 SE rd Figure 3 Display Unit STEP 5 Unscrew the Battery Cover Panel Screw 11 and remove the Battery Compartment Cover 5 from the Display Unit figure 3 Install the six 6 D cell batteries as indicated on the plastic battery cradle Replace the cover STEP 6 Adjust leveling feet located in each of the four corners of the underside of the Base Assembly to ensure that the scale will sit level on the floor Note Leveling feet must be in place to operate the scale properly INSTALLING OPTIONAL PRINTER STEP 1 Loosen the Phillips Pan Head screw and the black rubber bumper on the back side of the display until the display will lift off of the mast post STEP 2 Carefully loosen the display cable connector STEP 3 Slide the Printer Mounting Collar 9 over the Mast 2 Position the Printer Mounting Collar approximately 2 inches from the top of the Mast Tighten the two 2 set screws to secure the Printer Mounting
19. the sale of said articles In no event shall SR Instruments Inc be liable for any subsequent or special damages Any misuse improper installation or tampering shall void this warranty DAMAGED SHIPMENTS Title passes to purchaser upon delivery to Transportation Company Any claims for shortage or damage should be filed with the delivery carrier by purchaser RETURN POLICY All products being returned to SR Instruments Inc require a Return Goods Authorization number RGA To receive an RGA call our Technical Service Team at 716 693 5977 or toll free in the USA and Canada at 800 654 6360 When inquiry is made please supply model and serial numbers purchase order if the scale was bought on contract and reason for return Generally deleted damaged and outdated merchandise will not be accepted for credit A minimum restocking charge of 15 will be assessed on return of current merchandise All returns are to be shipped FREIGHT PREPAID to SR Instruments Inc 600 Young Street Tonawanda NY 14150 RESTOCKING FEE e 15 fee for any scale that has been opened and used e 10 fee for any scale returned that has been ordered incorrectly or refused delivery with no model change e 5 fee if an error in ordering has been made and a different model exchanged e No fees will be charged if the scale is returned because of an error on the part of SR Instruments Inc e No returns accepted after 60 days SR Instruments Inc 60
20. ting and Service Manual S N 6000 Part No MAN7257_140807 Page 18 of 22 CALIBRATION con t STEP 8 Place the FULL weight from Step 3 on platform Allow weight to stabilize Press UP arrow to save change Remove weight STEP 9 Press ENTER to save the calibration or WEIGH to exit without saving STEP 10 Switch the scale system out of the Calibration Mode on the display board Figure 13 STEP 11 Reinstall the side cover onto the display housing and secure in place with three 3 mounting screws CONFIGURING SEND BUTTON STEP 1 Press the MENU key until DATA OUT PRINT is displayed STEP 2 Press UP or DOWN key to select between EHR and PRINT STEP 3 Press the ENTER key to save EHR OUTPUT Electronic Medical Records EMR Electronic Health Records EHR technology is supported by the i series scales from SR Instruments The EMR EHR software is not included with scale There are many different EMR EHR software available and the connectivity of the scale to the software requires the services of a professional A null modem cable is required to communicate with the scale Scale output when send button is configured to Electronic Health Records is as follows lt esc gt R lt esc gt Wnnn n lt esc gt Hmmm m lt esc gt Bkk k lt esc gt Uuu lt esc gt E Where R is read W is weight nnn n is the weight in Lb or kg H is height mmm m is the height in inches or cm B is BMI kk k is the BMI U
21. uments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 10 of 22 SPECIFICATIONS MAXIMUM WEIGHT CAPACITY 1000 lb or 454 kg SR725i 32 in x 30 in 81 cm x 76 cm PLATFORM SIAE Waste 6 ne 30am Ol cae EE DISPLAY TYPE 16 Character dot matrix LCD DISPLAY RESOLUTION 0 1 Ib 0 1 kg 0 1 1 digit of displayed resolution for calibrated range ACCURACY AUTO ZERO One button operation AUTO POWER DOWN Approximately 30 seconds adjustable to 300 seconds ENTER Stores displayed reading in memory RECALLL Recalls last stored stable weight height and BMI AVERAGING Automatic digital filter POWER SUPPLY Six 6 D cell batteries CALIBRATION Calibration is traceable to NIST standards Normal operating conditions for this product OPERATING CONDITIONS Ambient Temperature Range 68 F to 85 F 20 C to 30 C Relative Humidity Range 0 to 85 Avoid exposure to high pressure water or steam Storage and transport conditions should not vary outside TRANSPORT and STORAGE the following conditions Relative Humidity 0 to 85 Ambient Temperature 14 F to 122 F 10 C to 50 C Remove batteries if storing longer than three 3 months SR Instruments Inc 600 Young Street Tona
22. wanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SR725i Wheelchair Scale Operating and Service Manual S N 6000 Part No MAN7257_140807 Page 11 of 22 BUTTON FUNCTIONS Figure 7 Button Display ZERO WEIGH Press and hold to zero The display will read WT 0 0 Lb This is used to zero the system before placing the patient on the scale system This action also resets previously stored weight height and BMI values to zero Ensure that nothing is in contact with the weighing surface during this procedure LE Press to weigh Weight stable indicator lf flashes then remains solid when stable Auto stores stable weight in memory SEND PRINTER EHR Press to send stored values to EHR or to printer Output values include time date weight height and BMI Also indicated on display when paper is out PAPER OUT and when door is open PAPER DOOR OPEN bal RECALL 5 Press to recall the last stable weight Display will scroll thru WT HT and BMP stored values in approximately two second intervals RECALL Sch MENU Press Menu to edit setup Setting the UNITS Use UP or DOWN arrow buttons to select Lb or Kg Press ENTER to save changes Setting ON TIME Use UP or DOWN arrow buttons to adjust the ON TIME The ON TIME may be set from 30 to 300 seconds in 30 seco
Download Pdf Manuals