Installation and Operation Manual

image

Contents

1. HH Hoi xx 4 0 Building Return S Za 4 gpm minimum flaw EE 6 E l S Le 1 1 call H 111 I LO Gitter t Gold Makeup i ples es s sma Expansion Tank Typical Single EZ Plate Plumbing Layout PV500 63 12 14 EZ PLATE WATER HEATERS SG Relief Valve LT Check Valve Solenoid Valve Isolation Ball Valve Dd Thermostatic Control valve II Union Y Strainer T Thermostat Pump Tamperatura Gauge Hot Outlet Se Pipe relef Pipe relief valvels to drain with na 52 to drain with no 22 yolves or restrictions valves restrictions m Ce ve T C H T 11 bei Pat xe zje 111 ez G ZE I I l 1 Building Return 4 gpm minimum flow AEN l l hd FOO 1 1 1 1 r Cold Makeup d a 4 f 4 Kees Expansion Tank Typical Dual EZ Plate Plumbing Layout Requires Balanced Reverse Return Piping PV500 63 12 14 4 1 4 2 EZ PLATE WATER HEATERS OPERATING AND SAFETY CONTROLS WARNING High Voltage Shock Potential Turn off all electrical service to the appliance prior to opening any water piping or accessing any controls components and wiring and fasten and close all water piping and electrical controls componen
2. WATER HEATERS 9 STANDARD EZ PLATE WIRING TEMPERATURE l S LIMITING DEVICE E BLK oo RED CHED a 19 60 Hz FUSE 120VAC gt SAFETY NEUTRAL WHT THERMOSTAT ATON I CONTROL SWITCH GROUNDING SCREW YEL YEL o SAFETY SOLENOID N C EZ PLATE POINT TO POINT WIRING DIAGRAM 10 60 gt 11 12BVAC N SAFETY SAFETY THERMOSTAT SOLENOID N C EZ PLATE LADDER WIRING DIAGRAM 14 PV500 63 12 14 EZ PLATE WATER HEATERS PV500 63 12 14 EZ PLATE WATER HEATERS MODEL NUMBER SERIAL NUMBER INSTALLATION DATE PVI INDUSTRIES LLC e 3209 Galvez Ave e Fort Worth Texas 76111 e Phone 1 800 433 5654 e www pvi com 16 PV500 63 12 14
3. noise and leaks Non destructive water hammer noise is expected during startup Extraordinary noise generation or leaking piping is reason to shut down the boiler water supply to the unit PV500 63 12 14 EZ PLATE WATER HEATERS 6 3 Operating Reminders In order to achieve maximum performance from the heat exchanger the following must be strictly followed 1 2 3 4 5 6 Pressures and temperatures must not exceed limits on product decal Heat exchangers must be free of any debris existing in the water The system must be designed to prevent the heat exchanger from encountering pressure shocks Prevent rapid temperature increases in the heat exchangers This would include installation of expansion tanks and safety valves into the system Prevent water in heat exchanger and piping from dropping below their freezing point A minimum of 4 gpm recirculation flow through the EZ Plate heater is required at all times 6 4 Shut Down 1 2 3 Valve off the supply of boiler water to the heater Allow a flow of domestic water until it runs cold Then shut off isolation valve at inlet of heater and then outlet Then disconnect electrical power PV500 63 12 14 7 1 7 2 7 3 7 4 EZ PLATE WATER HEATERS MAINTENANCE A preventative maintenance program should be established to assure a long trouble free life for the water heater WARNING High Voltage Shock Potential Turn off all electrical service to the appliance
4. the appliance and all accompanying parts for signs of impact or mishandling Verify the total number of pieces shown on packing slips with those actually received Contact the freight carrier immediately if any damage or shortage is detected Confirm that the system utilities are adequate to meet the heater requirements on the decal These units are suitable for indoor installation only The appliance must be placed on a level floor or housekeeping pad Do not attempt to move or lift heater by the plumbing connections or heat exchanger Lift only by the skid using industry standard safe rigging methods 5 Locate the unit so that if water connections should leak water damage will not occur Water damage is not covered by the manufacturer s warranty 6 Units and associated electrical components and electrical connections must be installed so they are protected from water dripping spraying rain etc during appliance operation and service 7 In hard water areas potable water treatment should be used to reduce introduction of minerals into the system Minerals in the water can collect on the plates and heat exchanger surfaces reducing the life of the product Heat exchanger failure due to scale accumulation is not covered by the product warranty Poe Nis Service Clearances A minimum clearance of 18 is recommended on all sides and above the appliance to facilitate easy access for inspection and service of installed components Optio
5. to a suitable drain hot water discharge can result in property damage scalding and personal injury or death IMPORTANT Thermal Expansion A relief valve that periodically discharges may result from thermal expansion if the water heater is installed in a system closed by components such as a backflow preventer or check valve in the old water supply These systems must be provided with means to control expansion Contact a water heater or plumbing professional to resolve this situation PV500 63 12 14 6 2 EZ PLATE WATER HEATERS DESCRIPTION OF OPERATION For proper operation of the EZ Plate the water heater must be supplied with boiler water at a minimum of 5 F above the water heater thermostatic element set point to a maximum of 180 F When there is no hot water demand the boiler and domestic water sides of the heat exchangers in this water heating system reach thermal equilibrium so it is constantly ready to provide hot water When hot water demand is initiated cold water enters the cold inlet port of the temperature control valve Cold water flows into the valve body where it is blended with hot water from the heat exchanger If the blended water temperature at the valve outlet increases or decreases from the specified temperature the internal ports reposition to change the amount of cold and hot water blended to again reach the specified blended water temperature When demand ceases the temperature control valve moves to seal th
6. INSTALLATION amp MAINTENANCE MANUAL EZ PLATE INSTANTANEOUS _ WATER HEATER W EN LOWLEAD Intertek COMPLIANT Installation and service must be performed by a qualified service installer or service agency IMPORTANT THIS MANUAL CONTAINS INFORMATION REQUIRED FOR INSTALLATION OPERATION AND MAINTENANCE OF THIS EQUIPMENT READ AND FOLLOW THE INFORMATION IN THIS MANUAL AND ALL OTHER PROVIDED INSTRUCTIONS LABELS AND MARKINGS BEFORE INSTALLING OPERATING OR SERVICING THIS EQUIPMENT HOT WATER OUTLET FD BOILER WATER INLET RS SHUT OFF VALVE TEMPERATURE CONTROL VALVE COLD WATER INLET CLEAN IN PLACE PORT BOILER WATER OUTLET Y STRAINER W BLOWDOWN Typical EZ Plate Construction TO THE INSTALLER After installation these instructions must be given to the equipment user or left near the appliance SPECIAL INSTRUCTIONS TO THE OWNER Retain this manual for future reference These instructions contain important information that will help you in maintaining and operating this appliance W MH PVI INDUSTRIES LLC Fort Worth Texas 76111 Web www pvi com Phone 1 800 433 5654 PV500 63 12 14 EZ PLATE WATER HEATERS TABLE OF CONTENTS Safety Considerations Water Heater Installation 2 1 Codes 22 Electrical Requirements 23 Checking Equipment Before you Install 24 Service Clearances General Piping Guidelines 3 1 Water Inlet Outl
7. S AND NURSING HOMES ELDER CARE FACILITIES AND REST HOMES ORPHANAGES AND CHILD CARE FACILITIES OTHER INSTALLATIONS WHERE RESPONSE TO CONTACT WITH HOT WATER MAY BE SLOWER OR WHERE THE DANGER OF HOT WATER CONTACT IS GREATER NS DANGER Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperature at water heater Feel water before bathing or showering If this appliance is used to produce water that could scald if too hot such as domestic hot water use adjust the outlet control limit or use temperature limiting valves to obtain maximum water temperature of 120 F Thermostatically controlled mixing valves must be used in the design of the potable hot water system Potable hot water should be tempered to no more than 110 F when used for bathing or other personal uses Good engineering practice mandates the use of thermostatically controlled mixing valves set at 120 F or less to keep the delivered water temperature below scalding temperatures PV500 63 12 14 2 2 2 3 2 4 EZ PLATE WATER HEATERS WATER HEATER INSTALLATION Codes The equipment must be installed in accordance with the instructions in this manual appliance markings and supplemental instructions and in compliance with those installation regulations in force in the local area where the installa
8. When installing or reinstalling seals always lubricate them with light food grade plumbing grease to make installing of the element easier and to prevent leakage from the housing Relief Valves Relief valves should be manually operated at least once a year and if it fails to freely discharge water or fails to reseat following testing it must be replaced with a like relief valve see installation section for description Y strainers Periodically blow down the valves on the y strainers If necessary shutdown heater remove and clean the mesh inside the strainer WARNING Use caution and proper personal protection when opening blow down valves Discharge from the blow down valves on the condensate y strainers is extremely hot Failure to use caution and proper personal protection when opening blow down valves can result in property damage instant scalding other personal injury or death 11 PV500 63 12 14 EZ PLATE WATER HEATERS 8 TROUBLESHOOTING SUGGESTIONS Problem Outlet water temperature is not constant a Cause Insufficient recovery Solution Verify heater rating is not exceeded Cause Recirculation inadequate Solution In certain conditions usually at very low flow inadequate system water recirculation can lead to unstable outlet water temperature Confirm the recirculation pump is operating properly and is providing a minimum of 4 gpm flow through the EZ Plate heater at all times Also confirm the EZ Plate heater h
9. a minimum flow rate of 4 gpm through the EZ Plate water heater at all times Connect the building hot water recirculation return line directly to the cold water inlet of the heater 4 Fix any system leaks DO NOT use stop leak products All system leaks must be repaired 5 After plumbing the unit and checking for leaks the heat exchanger and hot water piping should be insulated Insulation will reduce wasteful heat loss will help protect operators from contacting hot surfaces and is required to comply with ASSHRAE 90 1 and most state and local codes WARNING Insulate or guard all surfaces containing hot water Uninsulated or unguarded surfaces containing hot water can be hot enough to cause severe burns instantly if contacted Failure to insulate or guard all surfaces containing hot water can result in property damage personal injury or death Boiler Water Connections IMPORTANT Boiler and domestic water plumbing must be supported so that the EZ Plate water heater is not supporting any piping weight If there is weight put on the plumbing connections it could lead to corrosion of the heat exchanger or mechanical damage to the system that is not covered by the product warranty 1 All boiler and domestic water supply lines should be flushed before connecting the unit Failure to flush lines could cause components of unit to malfunction 2 The supply boiler water heater and plumbing must be adequately sized in order to provide the necessary
10. aned every six months or more frequently if there are higher scaling conditions Flushing can be done without removal of the heat exchanger from the system by using the clean in place ports located in the hot water outlet and cold water inlet piping near the heat exchanger Use only food grade cleaning agents When cleaning the heat exchanger also inspect the plumbing to the temperature control valve for scale build up If necessary de scale those hot water surfaces IMPORTANT Refer to the Bell amp Gossett Service Manual HF0358 for information regarding the service maintenance and how to clean the heat exchanger Temperature Control Valve The temperature control valve is factory set and not adjustable It should be inspected and internally cleaned every six months or more frequently if needed Replacement of the O ring seal is recommended when the valve body is opened to access the thermostatic element for inspection or replacement The thermostatic element can be checked by immersing it in an agitated bath of water Never use oil for checking the element At 10 F to 13 F above the nominal setting the bypass port B should be closed Replacement elements may be ordered from PVI The element part number and nominal temperature setting are stamped on the flange of the element If these are not known provide PVI the complete model number and serial number on the valve nameplate O ring seals should be replaced whenever replacing elements
11. directly into the dedicated relief valve fitting located near the top of the heat exchangers and the relief valve discharge must be plumbed to an appropriate floor drain The discharge line must allow complete drainage of the valve and line The water heater must not be operated without a correctly installed properly sized and properly operating relief valve If a replacement relief valve is required it must be of the same type pressure rating and relieving capacity as the original equipment supplied with the water heater A relief valve that discharges periodically may be caused by the thermal expansion of heated water when restricted by a backflow preventer or check valve installed in the cold water supply A means to control thermal expansion must be provided by a qualified plumbing professional Do not plug the relief valve Plugging the relief valve will eliminate the critical water temperature and pressure protection it is designed to provide WARNING Do not install a reducing coupling valve or other restriction between the relief valve discharge and a suitable floor drain Such restriction could prevent the valve from fully relieving if the pressure settings are exceeded which could result in property damage personal injury or death WARNING Secure the relief valve piping to a suitable floor drain such that very hot water does not openly splash during a significant relief valve discharge If the relief valve pipe is not routed and secured
12. e hot port In order for the temperature control valve to properly respond to changing hot water demand and to maintain proper temperature control a constant flow of at least 4 gallon per minute is required This flow is usually provided by connecting the pumped building hot water circulating return to the cold makeup water inlet A temperature limiting device monitors the temperature downstream of the temperature control valve If the valve does not hold the temperature close to its setpoint the temperature limiting device will shut the solenoid valve blocking flow of heated water to the outlet STARTUP PROCEDURE Pre startup Inspection 1 Confirm the domestic water supply pressure does not exceed the psi rating of the relief valve and the boiler water supply pressure does not exceed the heat exchanger pressure rating 2 The EZ Plate product uses either a double wall designated with DW in the model number or single wall designated with SW in the model number heat exchangers WARNING To avoid possible contamination of potable water in the event of a leak in a Single Wall SW heat exchanger plate water pressure in the heat exchanger must always be maintained above the boiler water supply pressure Potable water contamination resulting from failure to maintain water pressure in the heat exchanger above the boiler water supply pressure can cause personal injury exposure to hazardous materials or death If the pressure difference cannot be assu
13. et Connections 3 2 Boiler Water Connections Operating And Safety Controls 41 High Water Temperature Limit Control 4 2 Temperature Control Valve 43 Relief Valve Piping Description of Operation Startup Procedure 6 1 Pre startup Inspection 62 With All Product Valves Closed 63 Operating Reminders 64 Shut Down Maintenance 7 1 Maintenance and Cleaning the Plate Heat Exchanger 7 2 Temperature Control Valve 7 3 Relief Valves 4 Y strainers Troubleshooting Suggestions Standard EZ Plate Wiring Warranty forms ship separately with each product PV500 63 12 14 EZ PLATE WATER HEATERS 1 SAFETY CONSIDERATIONS WARNING Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any other items affecting safe appliance operation and which has been under water Failure to follow these instructions can cause property damage personal injury or exposure to hazardous materials or death IMPORTANT SAFETY NOTE It takes only 5 seconds of skin contact with 140 F water to cause second degree burn You must protect against high water temperatures at all lavatories tubs showers and other points of hot water contact Accidental scalding from high water temperatures is a greater risk in some types of installations Some examples are HOMES FOR THE MENTALLY OR PHYSICALLY HANDICAPPED HOSPITAL
14. heat recovery Consult PVI for assistance in sizing water heating equipment 3 A Y strainer with a blow down valve piped to a suitable drain must be installed in the boiler supply piping near the appliance 4 An air separator must be installed in the boiler piping near the appliance inlet 5 Insulate or guard all surfaces and pipes containing hot water WARNING Insulate or guard all surfaces containing hot water Uninsulated or unguarded surfaces containing hot water can be hot enough to cause severe burns instantly if contacted Failure to insulate or guard all surfaces containing hot water can result in property damage personal injury or death PV500 63 12 14 EZ PLATE WATER HEATERS Factory installed option Valve Pipe Unien Y strainer wf blowdown Dashed lines indicate items are field installed Camponents can be ordered separately from Isolation Check Vale Valve SR Zl so EE E WE i ele TT T Ki Drain Valve Typical EZ Plate Boiler Piping Layout E Relief Valve LJ Check Valve Solencid Valve Isalation Ball Valve Thermostatic Control Valve Union 7 Y Strainer I Thermestat E Pump F Temperature Gauge Fipe relief vqlve s to drain with na ES valves or restrictians d TI Hot Outlet 1 D
15. limit shutoff solenoid valve is energized but is not open service or replace the valve Cause The temperature limiting device is tripped Solution Confirm the limit device is set 10 F above the outlet water temperature element installed in the EZ Plate heater e g if the outlet water temperature element is 120 F the adjustable limit set point is 130 F If the adjustment is proper but still tripped confirm all other causes in this section are checked If the other causes are confirmed and a temperature limit device is still tripped replace the tripped device 12 PV500 63 12 14 EZ PLATE WATER HEATERS Problem Low Outlet Water Pressure a Cause Scale build up in heat exchanger Solution Schedule cleaning of heat exchanger Cause Solenoid valve closed Solution Check if thermostats are open If so then an over temperature condition occurred Shutdown unit and disassemble and inspect temperature control valves Cause Power loss Solution When there is no power to the unit the high limit shut off solenoid valve is closed Problem Water Leaking From the Heat Exchanger for DW double wall EZ Plate a Cause A continuous leak indicates one or more failed double wall heat exchanger plates Confirm the water is not from an external source Solution Refer to the Bell amp Gossett Service Manual HF0358 for information regarding the service repair and replacement of the heat exchanger PV500 63 12 14 EZ PLATE
16. nal equipment may increase the clearance requirements Also allow sufficient space for installing and servicing building water electrical pump and other auxiliary optional equipment and connections PV500 63 12 14 3 1 3 2 EZ PLATE WATER HEATERS GENERAL PIPING GUIDELINES WARNING All system piping to the heat exchanger plumbing must be adequately supported Failure to provide adequate support will result in excessive loads on the heat exchanger connections that can cause hot water discharge resulting in property damage scalding and personal injury or death Water Inlet Outlet Connections IMPORTANT Boiler and domestic water plumbing must be supported so that the EZ Plate water heater is not supporting any piping weight If there is weight put on the plumbing connections it could lead to corrosion of the heat exchanger or mechanical damage to the system that is not covered by the product warranty 1 Connect the domestic water inlet and outlet to the potable system Use backup wrenches on all threaded pipe connections to prevent damage to the heater plumbing Piping and components connected to the water heater must be suitable for potable water for the water temperatures they will experience and for their application 2 For ease of service install unions and shutoff valves on inlet and outlet piping to the unit 3 The EZ Plate water heater must be connected to a building recirculation system with a pump capable of maintaining
17. ot water isolation valve and any other valves in the recirculation line are open Cause Failed temperature control valve Solution Disassemble valve and replace temperature element and gaskets per valve manufacturers recommendations Problem Outlet water temperature is below set point a Cause Excessive flow rate Solution Water flow rate through heat exchanger surpasses its capacity Check flow rate and compare with heater decal Cause Excessive scale in heat exchanger Solution Scale on heating surfaces impedes heat transfer Inspect heat exchanger coil and schedule cleaning Cause Failed temperature control valve Solution Disassemble valve and replace temperature element and gaskets Cause EZ Plate heater hot water isolation valve closed Solution Fully open the EZ Plate heater hot water isolation valve Cause Solenoid valve closed Solution Indicated by low water temperature and lowered flow rate Check if thermostats are open If so then an over temperature condition occurred Shutdown unit and disassemble and inspect temperature control valves If not then solenoid valve has failed Replace Cause Power failure Solution This closes the solenoid valve also causing loss of hot water pressure Correct source of power loss Cause Insufficient supply of temperature or flow from boiler Solution Verify boiler loop operation Cause The high limit shutoff solenoid valve closed Solution If the high
18. prior to opening any water piping or accessing any controls components and wiring and fasten and close all water piping and electrical controls components and wiring before restoring electrical service to the appliance If the electrical service is not turned off and these points are wetted or touched a dangerous shock can occur which can result in property damage personal injury or death Maintenance and Cleaning the Plate Heat Exchanger A scale of lime will normally form during operation and will accumulate inside the heat exchanger Lime is formed from naturally occurring mineral compounds in the water which precipitate out during heating cycles Some water supplies contain more of these compounds than others and scale buildup will occur more rapidly Other factors affecting the rate of scale buildup are the amount of hot water used and the temperature of the water The more hot water used the more fresh water with scale forming compounds is brought into the heat exchanger As the temperature of water increases the rate of scale deposition will increase Debris or scale deposited in the heat exchanger will result in an increase in pressure drop lower temperature difference on the waterside or a high exit temperature on the boiler water outlet The frequency of cleaning will be determined by the rate of scale buildup Until the appropriate cleaning interval is established it is recommended that the heat exchanger be inspected and internally cle
19. red a double wall DW model should be used 3 The hot water system must have a pumped recirculation line that will maintain a minimum of 4 gpm flow through the EZ Plate heater at all times 4 Check all pipe fittings With All Product and Isolation Valves Closed Proceed As Follows 1 Switch on power to unit to activate the solenoid valves and thermostats The solenoid valve s should open 2 Crack open the boiler strainer blow down valve 3 Check the set point of the temperature limiting device near the hot water outlet The limit device is located downstream of the thermostatic mixing valve near the hot water outlet It must be set 10 F above the outlet water temperature element installed in the EZ Plate heater e g if the outlet water temperature element is 120 F the downstream limit set point is 130 F 4 Slowly open the domestic water supply valve to the EZ Plate heater Check for water leaks on waterside piping Crack open the domestic water outlet valve downstream of the EZ Plate heater to vent air from exchanger and piping It may be necessary to open a hot water faucet downstream in the system Continue venting air from the EZ Plate heater and piping until a consistent flow of water is demonstrated 5 Crack open the boiler supply to the heater and allow boiler water to flow through the boiler inlet strainer blow down 6 Slowly and fully open the main boiler shutoff valves IMPORTANT Special attention should be paid to
20. tion is to be made These must be carefully followed in all cases Authorities having jurisdiction must be consulted before installation is made In the absence of such regulations the installation must be in accordance with the instructions in this manual appliance marking and supplemental instructions and in compliance with the latest edition of the applicable state and local mechanical and plumbing codes Electrical Requirements This appliance is wired for 120 volt service The appliance when installed must be electrically grounded in accordance with the requirements of the authority having jurisdiction or in the absence of such requirements with the latest edition of the National Electrical Code ANSI NFPA No 70 When the unit is installed in Canada it must conform to the CAE C22 1 Canadian Electrical Code and or Local Electrical Codes e Supply 15 amp 120V service to each water heater Separate electrical circuits are recommended for multiple appliance installations e All wiring between the unit and field installed devices must be made with type T copper wire of proper size for the appliance load Damage resulting from use of aluminum wiring is not covered by the product warranty e Line voltage wire exterior to the appliance must be enclosed in approved conduit or approved metal clad cable Checking Equipment Before You Install Inspect the unit completely upon receipt from the freight carrier before signing the bill of lading Inspect
21. ts and wiring before restoring electrical service to the appliance If the electrical service is not turned off and these points are wetted or touched a dangerous shock can occur which can result in property damage personal injury or death High Water Temperature Limit Control The appliance is equipped with an adjustable temperature limit control The adjustable limit control is a manual reset type and should be adjusted at least 10 degrees above the operating temperature of the appliance It cannot be reset until the water temperature has dropped below its reset point Temperature Control Valve The non adjustable thermostatic valves are fully automatic 3 way fluid temperature control valves The valve is supplied with the temperature element assemblies factory set to the nominal temperature setting Temperature is sensed at Port A which remains open to Port B bypass until the fluid temperature reaches a point 5 10 F below the nominal setting As the temperature continues to rise the sliding valve moves to close off Port B and open Port C connected to the heat exchanger Port B is fully closed 8 10 F above the nominal setting The valve continually modulates the fluid flow to maintain the nominal temperature 4 3 Relief Valve Piping EZ Plate water heaters are supplied with pressure relief valves for each heat exchanger sized in accordance with ANSI ASME Boiler and Pressure Vessel Code Section IV The relief valve s must be threaded