Home
Single Bicarb Mix & Delivery Service Manual
Contents
1. So ele Sjejojn nj Power Cord not shown ELPCOO00200 INDUSTRIAL MOTOR DES __jmv N ___ENCL TEFC Ta VELLO BALL OSE BALL Ti SUE Mounting Hardware 4 each not shown Dayton SS Bolts HWBOSS01892 SS Lock Washers HWWASS01913 SS Washers HWW ASS01889 The Mixer Mount Spacer shown above is included on all Bicarbs produced from June 2006 to present Prior to June 2006 the Mixer Mount shown below was included but is no longer available pti HES ECHEN E at A Hii Mixer Motor EQBICB01868 Mounting Hardware 4 each Power Cord not shown SS Bolts ELPCOO00200 HWBOSS01886 SS Lock Washers HWWASS01913 SS Washers HWWASS01889 Mounting Hardware 4 each SS Bolts HWBOSS01888 SS Washers HWWASS01889 Mixer Mount This style no longer available SS Nuts not shown HWNUSS01888 Better Water LLC rev Jan 2014 Page 10 of 37 Single Bicarb Tank Central Mix and Delivery MIXER MOTOR SHAFT amp PROPELLERS CSHAF T LENGTH 33 3 4 1 2 10 1 2 n 11 F o Tes x SHAFT Ll fed gt PROP lt fel gt PROP MIXER MOTOR DIAGRAM SPACER 4 COUPLING lt fe gt PROP Better Water LLC rev Jan 2014 Page 11 of 37 Power Cord ELPCOO00200 Service Manual Mixer Motor EQBICB01868 Spacer EQBICBMXRMNT SS Coupling EQBICB00472 am pea
2. For models manufactured from mid July 2013 3 4 Blue Handle Valve Plast O Matic PLVAS8001 70 For models manufactured before mid July 2013 3 4 Blue Handle Valve Asahi PLVAS800170 A For models manufactured from mid July 2013 1 Blue Handle Valve Plast O Matic PLVAS8001 72 For models manufactured before mid July 2013 1 Blue Handle Valve Asahi PLVAS800172 A For models manufactured from mid July 2013 1 Red Handle Valve Plast O Matic PLVAS8001 74 For models manufactured before mid July 2013 1 Red Handle Valve Asahi PLVAS800174 A For models manufactured from mid July 2013 Pictures do not reflect the size of the item in relation to the other pictures Better Water LLC rev Jan 2014 Page 32 of 37 Service Manual PICTURE Single Bicarb Tank Central Mix and Delivery Service Manual RELATED REPLACEMENT PARTS DESCRIPTION High Level Proximity Sensor Subassembly For models manufactured from January 2009 Low Level Proximity Sensor Subassembly For models manufactured from January 2009 High Level Float Switch For models manufactured before January 2009 Low Level Float Switch For models manufactured before January 2009 Concentrate Regulator Calibration Kit For calibrating regulators in Floor Valve Boxes and Panels Blue wand is for bicarbonate Red wand is for acid Flow Control 2 0 GPM PVC Sch 80 Check Valve 1 2 316 Stainless Steel Volara Foam for Tank Lid 25
3. TK x 1 5 W 6 ft for 60 gallon Tanks 10 ft for 100 gallon Tanks PART PICTURE EQSUBTNK1HL AL EQSUBTNK1LL EQSUBBICBTNK1FL A EQSUBTNK1FL LOW S e m EQASSYCCO01 PLFCS802001 PLVASS00846 EQBICB01600 C Pictures do not reflect the size of the item in relation to the other pictures Better Water LLC rev Jan 2014 Page 33 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual RELATED REPLACEMENT PARTS DESCRIPTION PART PICTURE Bicarb Remote Alarm Box EQASSYBICB01709 TE a o fe Bicarb Control Box EQASSYBCB01854 Fuse 3 Amp Little Fuse ELLFFS00834 For models manufactured before mid September 2013 Fuse 2 Amp Little Fuse ELLFFS00832 For models manufactured after mid September 2013 Fuse Holder ELOTEL00833 Flow Switch 1 PVC Clear PLFSS800443 Pictures do not reflect the size of the item in relation to the other pictures Better Water LLC rev Jan 2014 Page 34 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual LIMITED WARRANTY TERMS and CONDITIONS a This limited warranty is given only to the original buyer and covers the equipment delivered with this limited warranty b The buyer shall be barred from any recovery on this limited warranty or otherwise for damages due in whole or in part to unreasonable use improper operation use beyond normal fashion failure to follow instructions fa
4. Better Water LLC Single Tank Bica r Central Mix and Deliver rev Jan 2014 Better Water LLC All rights reserved The content of this manual is the intellectual property of Better Water LLC It is furnished for the express use by Better Water LLC their customers and dealers for informational use only for operation service and internal training No part of this manual may be reproduced for distribution sale or any intent other than previously described without the written permission of Better Water LLC This manual is subject to change without notice Better Water LLC assumes no responsibility or liability for any error or inaccuracies that may appear in this documentation Adobe and Acrobat are registered trademarks of Adobe Systems Inc Better Water LLC 698 Swan Dr Smyrna TN 37167 www betterwater com Single Bicarb Tank Central Mix and Delivery Service Manual TABLE OF CONTENTS OUR COMPANY xscc0cc socaiechsccvectes lt ieeath ostesconeendscdvedensosbecceaesonneeslecseadratsoseshecesecdansott 01 AS oee US T A E T E A E E E EE ET 01 Technical Phone Support ccc cece cece cece eee cece eee e eae ee tenet teat eeeeeeaeeneeeeaeeateeanenas 01 Technical Support Info Online 0 ccc ccc cece eee e eee e eee e cena ee eeeeeeaee seats eeateeaeeeaeees 01 OPECIN GOMAGCIS errepre EE EAr EEE EEE 02 Modu O eere E a a E E E eee 02 Warnings amp an t 10 0 a gt 03 NOGE serrer E acoso
5. 4 Remove the mounting hardware nuts from underneath the Tank Base from the four mounting holes 5 Remove the pump replacing with the new one 6 Remount the pump to the Tank Base using the mounting hardware See Pump Mounting Hardware diagram below 7 Reconnect the 3 4 Hose and the 1 Hose to the pump 8 Plug the Bicarb s Main Power Cord into an electrical receptacle i a te yA E N Fm i va p 3 4 Worm Drive Hose Clamp x2 PLHOCLO002 1 Worm Drive Hose Clamp x2 PLHOCLO003 PLFIPO01230 1 x 3 4 Pg Reducer zm 7 PLHOSU01237 1 Suction Hose 100 gal 20 60 gal 12 1 PLHOST00315 3 4 Style 5000 Hose 100 gal 36 60 gal 30 a 9 ELHBPL00765 Hubble 2 Pole 3 Wire 15A 125V NY PL Reference DWG 3303 Better Water LLC rev Jan 2014 Page 20 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual PUMP MOUNTING HARDWARE Pump Base Mounting Hole x4 1i 1 4 20 x 1 1 2 Bolt x4 HWBO0001910 A 1 4 SS Flat Washer ae aA aN ae 1 3 4 x 3 8 x 3 8 Rubber Bumper x4 HWBUO0000439 _ D gt TANK BASE 1 4 SS k Washer x4 k 931 1 4 SS Flat Washer x4 HWWASS01888 1 4 20 SS Nut x4 HWNUOO01245 Better Water LLC rev Jan 2014 Page 21 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual PLUMBING HEADER and TANK DIAGRAM Loop Bicarb Return Return Connection from L
6. RAE PEE NCEE REV Better Water LLC 698 Swan Dr Smyrna TN 37167 www betterwater com Better Water LLC rev Jan 2014 Single Bicarb Tank Central Mix and Delivery Service Manual Better Water LLC is a leading integrated manufacturer of water treatment Our 7 i Te equipment and components for the industrial commercial and institutional Company markets Located in Smyrna Tennessee ANR Better Water LLC continues its history of manufacturing and distribution of i equipment specifically designed for the renal dialysis market F ri Founded in 1971 Better Water LLC has _ built a reputation for solving our customers toughest problems with high quality products and unmatched service Better Water LLC Technical Support 698 Swan Dr Phone 615 355 6063 press 1 Smyrna TN 37167 Email support betterwater com Phone 615 355 6063 Customer Service Fax 615 355 6065 Phone 615 355 6068 press 3 Email customerservice betterwater com Technical Support is available regarding all Better Water LLC systems Phone 24 hours a day 7 days a week S i e Normal business hours are Monday through Friday from uppor 8 00 am until 3 30 pm Central Standard Time excluding holidays Call 615 355 6063 press 1 for Technical Support Emergency assistance is available after normal business hours including holidays by calling 615 708 8627 BEFORE calling for emergency assistance e Check the Troubleshooti
7. 2013 PLVAS800172 cr i 3 4 90 Poly Nipple x2 PLFIPO00351 T SAR Distribution Pump EQPUIW00453 Drain Valve 1 Pre July 2013 PLVAS800174 Post July 2013 PLVAS800174 A _ ae Close Up of Pump And Drain Connection Better Water LLC rev Jan 2014 Page 7 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual SINGLE BICARB BACK VIEW High Level Sensor Pre 2009 float EQSUBBICBTNK1FL 2009 sensor EQASUBTNK1HL Flow Switch 3 4 PVC Clear PLFSS800443 Low Level Sensor Pre 2009 float EQSUBTNK1FL LOW 2009 sensor EQSUBTNK1LL i lj Clear Suction Hose 1FT PLHOSU01237 Better Water LLC rev Jan 2014 Page 8 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual LID amp MOUNTING HARDWARE Mounting Hardware Kit for 2 Bicarb Lids lt No Part Numbers 10 holes per lid 10 of each 1 3 8 x 1 4 Bolt 1 4 Flat Washer 1 4 Locking Washer 1 4 Nut VOLARA FOAM for Tank Lid If replacing the Volara Foam 25 thick x 1 5 width that helps seal the lid to the tank refer to the following 6 ft for 60 gallon Tanks 10 ft for 100 gallon Tanks Volara Foam 25 x 1 5 EQBICB01600 Better Water LLC rev Jan 2014 Page 9 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual MIXER MOTOR MOUNTS Mixer Motor Mixer Mount Spacer EQBICB01868 EQBICBMXRMNT
8. Fil SUDASSEMDIY asiwe ewe since eccldinthernte secre yap mie slo n re end teeta re neste EAE n A oe 19 s pc 8 cle 96 INO PUMP ee ee he er a ee a a ree 20 Pump Mounting Hardware isss ccc ae sareste en aeeeremetnnctaps ane nnateuriwuleamtese nian Heneienmane tu veamasookdiadanlts 21 Plumbing Header and Tank Diagram cccccce ese e eee e nese eee eaeeeeeeeaeeeaeeeaeeeaeeeneeaes 22 aig C1018 08 HEaQEI ee ea ea 23 Bicarb Valves Descriptions cc ccc cece cece esse ences eeseeeeseteeaseesaeeeaeetsgeeesanetsaneeags 24 Bicarb Flow Diagral sacomidantinadqedaeanncaledarataiptediounkeiakantedortcntetaanesnsiaihiensmaeasheads 25 Control Box F VICW e E E 26 Inside Box View pre January 2005 ccc ccc ccc c cence eee e eee e eee eeeee eee eaeeeaeeeaeeeanenaes 27 Inside Box View post January 2005 c ccc cc ccc cece eee eee cent eee eeeeeeaeeeaeeeaeeeaeeeaneass 28 ANE AEE VION ca crcppccay cc scones ina sam ieonneamaeandemanemen satads oe econeasaondt anne E EE 29 VVC SC Me Male src isinir in REE E eSa 30 Related Replacement Parts cccccccecc cece eee cess eee e eee e eee eeeee eae eeaeeeaseeaeeeaeegaeenanags 31 Limited Warranty Terms and Conditions ccccc ccc e ence eee cece eee ee eee eaeeeaeeeaeeeaeeeaneass 35 Better Water LLC rev Jan 2014 Single Bicarb Tank Central Mix and Delivery Service Manual s Te a i 3l ST ee isit our website to see our cor 4 WALI TC
9. Level Sensors When a Float Switch is suspected of poor functionality or failure this test should be performed This is the same test performed at the Better Water manufacturing facility on returned Float Switches to verify warranty claims 1 Obtain a two lead multi meter and place in continuity mode 2 Attach the multi meter leads to the contacts on the Float Switch wire NOTE The wire colors are different between the High Level and Low Level Float Switches 3 Cycle the Float between open and close by raising and lowering the Float 4 Take note as to whether the multi meter alarms with the action of the Float reliably The multi meter should steady alarm when the Float is in the closed position HIGH LEVEL FLOAT SWITCH alarms on the multi meter when in the UP position LOW LEVEL FLOAT SWITCH alarms on the multi meter when in the DOWN position HIGH LEVEL FLOAT SWITCH EQSUBBICBTNK1FL Alarms on the multi meter when in the UP position Attach multi meter leads to the Float Switch wire connection holes here LOW LEVEL FLOAT SWITCH EQSUBTNK1FL LOW Alarms on the multi meter when in the DOWN position Better Water LLC rev Jan 2014 Page 16 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual REPLACING FLOAT SWITCHES WHITE FLOAT SWITCHES vs BLACK FLOAT SWITCHES A change was made in the float switches in January 2006 Prior to this a shorter white float switch was used and after a longer blac
10. loop In an emergency situation this valve can be closed and all flow to the distribution loop will cease Rinse Down Valve B 16 This valve when open will allow water to flow through a connected hose to rinse down the inside of the tanks Disinfect Valve B 21 This valve is used to rinse the Bicarb distribution loop When opened dialysis water will enter the Bicarb distribution loop The Return to Drain Valve should be open and this will flush the distribution loop of all Bicarb solution or disinfect solution Loop Return Sample Port This valve will allow the user to take a sample of the liquid flowing from the distribution loop This can be used to verify a Bicarb Solution or to verify the presence or absence of disinfectant solution Tank Fill Solenoid Valve This valve receives a signal from the High Level Sensors in Tank and the Tank Selector Switch on the front of the Control Box If the level of liquid is above the High Level Sensor this Solenoid Valve will not open This Solenoid Valve and the High Level Sensors are deactivated when the Keyed Disinfect Switch is in the ON position Better Water LLC rev Jan 2014 Page 24 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual Flow Restrictor When installed the Flow Restrictors are installed to only allow 2gpm to flow though the fill lines This will prevent the filling process from using too much water from the distribution loop and possibly causing
11. ocec socautecesse a E 04 Important Information for SUPPOFt ccc cece cece cece unka eee e ee ee eee eeeeeaeeseeae eae EER 04 Model Changes Relevant for Support and Replacement Parts cccceeeeeeeeeeeees 05 Single Bicarb SPOME V IOU axcantntanads ads E EE hand measanvunemenenennerinanicinsucieoamernedeton 07 SID ACK VCW eisai a a a E E E a E E 08 Lid And MOUNUNG Hardware sesisissisisidrscopruriasdanai piiinbtea iaus ir inier eria 09 IKK Motor MOUNIS stat ncaanchacikecitakaobeasn eE EEE E a Aaina 10 Mixer Motor Shaft amp Propellers Diagram ccc ccc cece cece eee ee eee eeeeeeeeaeeeeeaeeeeaees 11 Replacing Propellers Shaft and or Coupling 0 cece cece cece cece ee eee seas eeeeeeeeaeeneeaas 12 Se DlaGInG a Mixer MOTOT swine ceuacecdeowdersvercieccdaustudaivrsaiessiveessatdiuaneivexngieeurwdvaner 13 Return to Tank Fitting Drop Down Tube c ccc ccc eee e cece e cence tenet eases aeeeateeaeeeaes 14 Pill niet COMING CHONG ctcncer eerste csesecxseeuencsbeneserecbaccsacersdsssasinseccedesesesecy caes steeseunses 15 Verifying Float Switch Functionality cccc ccc ccc cece ee cece eee e sees teases eeeeeaeeneeeaeenees 16 Replacing Float SWUCHES ccce0secs recs dccsceseccndensaedocaxe sasieedocurbucwheceaaesedcapsesstecedseeseen hs 17 Replacing Proximity Sensors lt cgcscceotseieiase sicensusieenuce eee wsienecuben ene daieds lee sete eptiaeeeneneestens 18 a CCL
12. r f j i i 1 PLPIS800045 1 PVC Sch 80 Pipe 2 3 16 length 2 3 4 PVC Sch 80 Pipe 1 15 16 length a 3 4 PVC Sch 80 Pipe 4 7 16 length 3 4 PVC Sch 80 Pipe cut to fit approximately 8 a x 4 PVC Sch 80 Nipple cut in half a e Ptrseoooso PveSenenTeeSeSe8 7 PLFIS800062 1 PVC Sch 80 90 Elbow SxS a 8 PLFIS800072 3 4 PVC Sch 80 45 Elbow SxS 2 a puvaseonr7o a aH Bh asaran 3 4 MPT x 3 4 HN Polypro Elbow Nipple 11 PLFIS801914 1 Sx 1 S x 3 4 S Sch 80 Tee Reference DWG 3083 REPLACEMENT INSTRUCTIONS IF BROKEN In the event this assembly gets broken it can be replaced The parts required will depend upon at which point the repair can be made which should be at the pipes item 3 or 4 or at the connection to the bottom of the tank item 5 A 3 4 Coupling 2 1 8 length may be required to connect if the pipe is broken item 1 2 2A or 2B This part number is PLFIS800928 Additionally two sections of 1 PVC Sch 80 Pipe may be required which connect to item 6 Tee and item 7 Elbow This part number is PLPIS800045 13 for 100 gallon 9 3 16 for 60 gallon Better Water LLC rev Jan 2014 Page 19 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual REPLACING the PUMP 1 Unplug the Bicarb s Main Power Cord 2 Unplug the cord from the Pump to the Control Box 3 Disconnect both the 3 4 Hose and the 1 Hose from the pump
13. to prevent upward water splash 5 Remove the Lid bolts and nuts so the lid can be lifted not removed 6 Lift the Lid and remove the bolts and nuts holding the Motor to the Motor Mount 7 Lift the Motor straight up to expose the Coupling and Shaft above the Lid then take a pair of vice grips and clamp them to the Shaft below the Coupling This should allow enough support and access to proceed 8 Remove the top two Set Screws in the Coupling then remove the Motor carefully laying it on top of the Tank sideways 9 Attach the new Motor to the Coupling with the Set Screws Use Lock Tight on each of the Set Screws before tightening because motor vibration will cause the set screws to back out which can cause damage to the motor and or shaft assemblies 10 Remove the vice grips and allow the Coupling and Shaft to slip down through the Motor Mount back into position 11 Align and reattach the Motor to the Motor Mount using the previously removed bolts and nuts 12 Realign the Lid and reattach to the Tank using the previously removed bolts and nuts 13 Plug the Motor s Power Cord into the Control Box 14 Plug the Bicarb s Main Power Cord into an electrical receptacle Better Water LLC rev Jan 2014 Page 13 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual RETURN to TANK FITTINGS DROP DOWN TUBE Return to Tank Fitting Drop Down Tube inside tank Top View of Lid Showing H
14. Control Box Lid PUSH BUTTON WIRE COLOR CHART Mmmm BLACK ae WHITE Gam BLUE mum GREEN Gam PURPLE m RED m BROWN mem YELLOW ij mmm ORANGE M mii 2 2 SI E oO S 6 HO0 lt m Fl OY O B i MATE N LOCK 7 3 PIN FEMALE PO CONNECTOR JOS oy exexe NOTES GRAY LINES WHITE WIRES NEUTRAL Ci 2 125 ee oi 300 VAC TORQUE 7 10 in lbs PPR FEA Sonte SEa GE Soar ane CONNECTOR CONNECTOR CONNECTOR CONNECTOR Better Water LLC rev Jan 2014 Page 30 of 37 Service Manual Single Bicarb Tank Central Mix and Delivery DESCRIPTION Propeller Shaft 316 Stainless Steel RELATED REPLACEMENT PARTS PART EQBICB00471 Propeller EQBICB01923 Polypropylene Propeller Set Screw EQBICB01920 Stainless Steel Shaft Coupling EQBICB00472 Stainless Steel Coupling Set Screw HWSCSS01920 Stainless Steel Mixer Motor EQBICB01868 1 4 HP 115 VAC Mixer Motor Power Cord EQPCOO00200 For Mix Delivery Bicarbs MD 100RLT Pump EQPUIW00453 1 3 HP 1 Phase 115 VAC PICTURE Pictures do not reflect the size of the item in relation to the other pictures Better Water LLC rev Jan 2014 Page 31 of 37 Single Bicarb Tank Central Mix and Delivery RELATED REPLACEMENT PARTS DESCRIPTION PART 3 4 Red Handle Valve Plast O Matic PLVAS800169 For models manufactured before mid July 2013 3 4 Red Handle Valve Asahi PLVAS800169 A
15. Disinfect protection for Relay Mix times Level Sensors for the Pump Start Tank 1 eft and Relay Base Distribution Relay Base 2 right ELIDRLO1142 Pump Relay Base ELIDRLO1143 Relay Base ELIDRLO1142 ELIDRLO1142 Relay ELIDRLO1146 ELSICNOO1 Relay ELIDRLO1145 Relay ELIDRLO1146 Relay ELIDRL0O1146 NOTE No picture was available of the inside of the Single Bicarb Control Box built prior to January 2005 The picture shown is that of a Dual Bicarb Control Box built prior to January 2005 The only difference is the three Receptacles are on the bottom of the box rather than the back Better Water LLC rev Jan 2014 Page 28 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual CONTROL BOX Inside of Lid View Part EQASSYBCB01854 Part Numbers For All Models Keyed Disinfect Start Button Mixer Control Switch Switch ELPWSW01133 ELPWSW01132 ELPWSW01135 Tank Fill Switch Off Operate Switch ELPWSW01132 ELPWSW01134 k mA Replacement Bulb Tool Tank Alarm Switch Indicator Light Fuse Holder ELOTEL02060 ELPWSW01132 ELLPS01894 ELOTEL00833 Better Water LLC rev Jan 2014 Page 29 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual MATE N LOCK _ 2 PIN FEMALE CONNECTOR MATE N LOCK 2 PIN MALE CONNECTOR DS MATE N LOCK 3 PIN MALE CONNECTOR uc CONTROL BOX WIRING SCHEMATIC Part EQASSYBCB01854 printed on inside of
16. ENCE BY BETTER WATER LLC a Buyer s sole and exclusive remedy for any breach of this limited warranty or negligence by Better Water LLC shall be repair or replacement of the defective part at the option of Better Water LLC provided such defective part is returned to Better Water LLC for inspection b Better Water LLC shall not be obligated to supply an exact replacement of the defective part and reserves the right to substitute new and improved parts c Better Water LLC shall provide at no cost to buyer labor to remove and or replace defective parts covered by this limited warranty for a period of ninety 90 days from the date of installation by Better Water LLC of the equipment d After such ninety 90 day period buyer shall be responsible for any labor or service charge for the removal and or replacement of any defective parts e Buyer shall be responsible for all travel expenses and freight charges at all times f Better Water LLC shall have no obligation to repair or replace any defective part if buyer fails to follow the procedure set forth in HOW TO OBTAIN A REPLACEMENT PART UNDER LIMITED WARRANTY IN NO EVENT SHALL THIS LIMITED WARRANTY BE CONSTRUED TO COVER NOR SHALL BETTER WATER LLC BE LIABLE TO BUYER AS ANY OTHER PERSON FOR ANY CONSEQUENTIAL INCIDENTIAL ECONOMIC DIRECT INDIRECT GENERAL OR SPECIAL DAMAGES WHICH ARE HEREBY EXPRESSLY DISCLAIMED Better Water LLC rev Jan 2014 Page 35 of 37 Single Bicarb Ta
17. PO00351 PLVASS00845 1 x 1 2 SS Bushing Reducer PLFISS00849 1 SS Tee PLFISS00870 Better Water LLC rev Jan 2014 Page 23 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual BICARB VALVES LEGEND amp DESCRIPTIONS Fill Valve This is the main valve used to fill the Tank NOTE Tank Fill Switch on Control Panel must be in the Tank 1 position to fill Once the level in the tank reaches the High Level Sensor the Solenoid Valve will close and water flow will cease Loop Return Valve to Tank B 6 When the pump is operating and when this valve is in the OPEN position liquid will return to Tank Return to Drain Valve When the pump is operating and when this valve is in the OPEN position liquid will return to Drain Jug Fill Valve After Bicarb Solution is mixed this valve is used to take a sample to verify the Bicarb Solution is mixed properly from Tank After bicarb solution is verified this valve is used to fill jugs from Tank if needed During the disinfect procedure this valve can also be used to verify the presence of disinfectant Service Valve This valve is used to allow liquid to be pumped from Tank through the pump and to the distribution Loop When this valve is closed Tank will be isolated from the pump and distribution loop Drain Valve This valve is used to drain all liquid from Tank Loop Service Valve This valve must be open to pump any liquid from Tank to the distribution
18. Set Screws x4 HWSCSS01920 SS Shaft EQBICB00471 Poly Pro Props x3 EQBICB01923 y Set Screws x3 7 per prop EQBICB01920 B Single Bicarb Tank Central Mix and Delivery Service Manual REPLACING PROPELLERS SHAFT and or COUPLING 1 Unplug the Bicarb s Main Power Cord 2 Remove the Lid bolts and nuts so the lid can be lifted not removed 3 Lift the Lid and remove the bolts and nuts holding the Motor to the Motor Mount 4 Lift the Motor straight up to expose the Coupling and Shaft above the Lid then take a pair of vice grips and clamp them to the Shaft below the Coupling This should allow enough support and access to proceed 5 Remove the top two Set Screws in the Coupling then remove the Motor carefully laying it on top of the Tank sideways 6 The Coupling can remain attached to the Shaft if neither of these two pieces are being replaced If replacing the Shaft or Coupling then remove the bottom two Set Screws in the Coupling and set it aside 7 Lift the Lid and take hold of the Shaft before removing the vice grips then remove the Shaft from the Tank 8 Remove each Propeller from the Shaft by loosening its related Set Screw It may be necessary to use a hammer to gently tap down the Propellers to remove them from the Shaft 9 Replace each Propeller aligning the Set Screw with the etched groove then tighten carefully NOTE Over tightening can cause the threads on the propeller to str
19. White Float Switch Longer Black Float Switch June 2006 Mixer Motor Mount Change Prior to June 2006 the mixer motor was mounted on an elongated plastic mount which raised the motor a few inches above the lid After June 2006 on a flat plastic mount was used which lowered the height of the mixer motor The mounting hardware also changed to accommodate the new mount These changes are detailed in the Mixer Motor Mount section below t a ponnn npea nS Prior to June 2006 Elongated Mount After June 2006 Flat Mount Better Water LLC rev Jan 2014 Page 5 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual January 2009 Change from Float Switches to Proximity Sensors Prior to January 2009 High and Low Level Float Switches were used which are mechanical in nature From January 2009 and beyond electronic sensors were used and they are not interchangeable These changes are detailed in the Single Bicarb Back View as well as the Replacing Float Switches sections below Prior to January 2009 From January 2009 Description part Description part High Level Float Switch Tank 1 EQSUBBICBTNK1FL High Level Sensor Tank 1 EQSUBTNK1HL Low Level Float Switch Tank 1 EQSUBTNK1FL LOW Low Level Sensor Tank 1 EQSUBTNK1LL Mid July 2013 Ball Valve Change Units manufactured before mid July 2013 contained Plast O Matic ball valves which were changed to Asahi ball valves These valves are not intercha
20. an be filled to capacity for disinfection and OFF OPERATE Switch Main Power Switch TANK FILL Switch START Button This switch opens After turning Off the inlet solenoid Operate Switch to rinsing valve to fill the tank OPERATE Push and ELPWSW01132 Hold Start Button until Keyed Disinfect Switch ELPWSW01132 Green Indicator light ELPWSW01135 stays on Start Button ELPWSW01133 Replacement Key ELIDRL01130 Replacement Clear Rubber Boot ELPWSW01134 Better Water LLC rev Jan 2014 Page 26 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual CONTROL BOX Inside Box View Part EQASSYBCB01854 Functions amp Part Numbers For Models Produced from January 2005 Mixer Contactor Pump Contactor Smart Relay 24V Expansion 5 5 8 amp 2 8 4 amp The main controller Module 24V Transformer Provides overload Provides overload that controls all of Works in This will convert protection protection the functions of the conjunction the incoming Bicarb Unit with the Smart 120vac power and ELSICN015 ELSICN013 Relay to 24vac to run ELSIRLO12 the Smart Relay ELSIRLO14 ELMTTRO1380 no MTGOOSOC i435 Leas 3 24 2 gt ca VA50 HZ 50 60 W s gt eet 71 T Sine o OUTPUT VA 50 138 in aa W wa F eg ADMES SIBLE INST waaau ourna MAT IECSS8 CEEI ET meer iy Ce rey E ee 980 3t Pisa
21. e Manual has been developed for the purpose of ordering factory replacement parts and for Troubleshooting the Single Bicarbs This Service Manual is not intended to replace the Operator Manual but serve as a Supplement to it Current versions of this Service Manual and the Operator Manual as well as other helpful information can be found on our website at www betterwater com support It is important to understand that the Better Water Bicarb Unit is a Class I Medical Device and that non factory replacement parts could affect the safety performance and warranty of the unit This manual includes parts lists photographs schematics and diagrams to assist you in servicing the unit Better Water LLC rev Jan 2014 Page 2 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual WARNINGS 1 It is unsafe to operate or service this device without first reading and understanding the entire Operator and Service Manuals Keep this manual and other associated documentation for future reference 2 Misuse improper operation and or improper monitoring of this system could result in serious injury death or other serious reactions to patients undergoing hemodialysis treatment 3 Misuse improper use or handling of disinfectants and chemical cleaning solutions could result in serious injury or even death You must comply with the information contained in the Material Safety Data Sheet MSDS for the chemical being used 4 T
22. hat its normal position is bent at the pivot at a 90 degree angle hanging down such that it will pivot to a straight out position when floating 5 Reconnect the Float Switch s Wire Connection to its corresponding Control Box s Pigtail Connection Better Water LLC rev Jan 2014 Page 17 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual REPLACING PROXIMITY SENSORS Proximity Sensors Prior to January 2009 High and Low Level Float Switches were used which are mechanical in nature From January 2009 and beyond electronic proximity sensors were used and they are not interchangeable If Float Switches are required see the section above on Replacing Float Switches Description part High Level Sensor Tank 1 EQSUBTNK1HL Low Level Sensor Tank 1 EQSUBTNK1LL REPLACEMENT INSTRUCTIONS 1 Disconnect the Proximity Sensor s Wire Connection from the Control Box s Pigtail Connection 2 Carefully unscrew the old Proximity Sensor from the Bulkhead 3 Place the new Proximity Sensor into the Bulkhead and carefully thread taking care not to over tighten it 4 Reconnect the Proximity Sensor s Wire Connection to its corresponding Control Box s Pigtail Connection Better Water LLC rev Jan 2014 Page 18 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual JUG FILL SUBASSEMBLY Ho SECTION 1 A m SECTION 2 S i g p i i A l 4 i r oo e i f i i
23. ilure to maintain the product in good condition and repair or the like c If the buyer discovers or should have discovered a defect in which it is reasonable to conclude that damage either personal property or economic may result the buyer s continued use of the product shall constitute any assumption of risk by the buyer and a bar to any recovery for breach of this limited warranty or otherwise d No oral or written representation information or advice given by Better Water LLC or any of its representatives shall create a warranty or in any way increase the scope of this express limited warranty and shall not form a part of the basis for bargain WHAT IS WARRANTED AND FOR HOW LONG a All equipment excluding ion exchange and filtration media and cartridges are warranted to be free from factory defects in materials and workmanship under normal use for a period of one 1 year from the date of shipment b It is a condition precedent to recovery on this limited warranty that the buyer strictly comply with all operating and maintenance guidelines established by Better Water LLC and that the serial number if applicable is intact and legible on the equipment c It is a condition precedent to recovery on this limited warranty for damage to the external finish of the equipment that the buyer notifies Better Water LLC at the time of the installation that the finish is damaged WHAT IS REMEDY FOR BREACH OF THIS LIMITED WARRANTY or NEGLIG
24. ip 10 Lift the Lid take hold of the Shaft and reinsert it back into the Tank and up through the Mixing Motor Mount Hold in place with a pair of vice grips leaving enough room above the Shaft to reattach the Coupling 11 Reattach the Shaft to the Coupling then the Motor to the Coupling with the Set Screws Use Lock Tight on each of the Set Screws before tightening because motor vibration will cause the set screws to back out which can cause damage to the motor and or shaft assemblies 12 Remove the vice grips and allow the Coupling and Shaft to slip down through the Motor Mount back into position 13 Align and reattach the Motor to the Motor Mount using the previously removed bolts and nuts 14 Realign the Lid and reattach to the Tank using the previously removed bolts and nuts 15 Plug the Bicarb s Main Power Cord to an electrical receptacle Better Water LLC rev Jan 2014 Page 12 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual REPLACING a MIXER MOTOR 1 4 HP Mixer Motor Bicarb Power Cord EQBICB01868 ELPCOO00200 1 Unplug the Bicarb s Main Power Cord 2 Unplug the Motor s Power Cord from the Control Box 3 Remove the old Motor s Wiring Cover and un wire the Power Cord 4 Remove the new Motor s Wiring Cover and re install re wire the Power Cord consulting the wiring diagram on the new motor and wire for low voltage Replace the Wiring Cover when KO Wire for clock wise rotation
25. k Central Mix and Delivery Service Manual MODEL CHANGES RELEVANT for SUPPORT and REPLACEMENT PARTS The following is a summary of changes that were made and the time period they were made in that are relevant to support and determining the correct replacement part numbers Refer to the section above concerning the serial number in determining the year and month the device was manufactured to determine the relevance of these changes to your device January 2005 Control Box Change The following changes were made to the Control Box Changed from multiple standard relays to a single smart relay and expansion module Changed from a contactor thermal overload to branch circuit protection These changes are detailed in the Control Box Inside View section below January 2006 Float Switch Change A change was made in the float switches in January 2006 Prior to this a shorter white float switch was used and after a longer black float switch The shorter white float switches are no longer available so the float switches described below can be ordered as a replacement If this is done a new bulkhead through which the float switch is installed is required This new bulkhead must have the inside enlarged to accommodate the area required for full motion of the longer black float switches See the Single Bicarb Front View as well as the Replacing Float Switches sections below A pe Prior to January 2006 After January 2006 Shorter
26. k float switch The shorter white float switches are no longer available so the float switches described below can be ordered as a replacement Prior to January 2006 After January 2006 Shorter White Float Switch Longer Black Float Switch Description part High Level Float Switch EQSUBBICBTNK1FL Low Level Float Switch EQSUBTNK1FL LOW If this is done a new bulkhead through which the float switch is installed is required This new bulkhead must have the inside enlarged to accommodate the area required for full motion of the longer black float switches The part number for this bulkhead is PLFIPOQ00321 If placing an order for this bulkhead please note on the order Drill Out Enlarge for Old White Float Switch REPLACEMENT INSTRUCTIONS 1 Disconnect the Float Switch s Wire Connection from the Control Box s Pigtail Connection 2 Carefully unscrew the old Float Switch from the Bulkhead 3 Place the new Float Switch into the bulkhead and carefully thread taking care not to over tighten it 4 Correctly orient the Float Switch s Mechanical Float by turning the Float Switch either clock wise or counter clockwise HIGH LEVEL FLOAT SWITCH The Mechanical Float should be oriented a Ire so that its normal position is sticking straight out such that it will pivot at the joint to bend upward at a 90 degree angle when floating LOW LEVEL FLOAT SWITCH The Mechanical Float should be oriented so t
27. ng guide in this manual e Check the electrical power connections fuses circuit breakers if applicable e Check all valves to ensure each is in the correct position if applicable Our website WwWW betterwater cCom which is updated Technical frequently contains a wealth of technical support information on the SUPPORT tab and includes Support e Operator and Service Manuals Info e Interactive Frequently Asked Questions for Troubleshooting Tal a e Consumables and Accessories Lists e Technical Service Bulletins For your convenience there are also online forms for placing Orders and requesting Returned Goods Authorization These are Adobe forms that can be downloaded and either faxed or emailed to us Better Water LLC rev Jan 2014 Page 1 of 37 Specific Contacts Introduction Single Bicarb Tank Central Mix and Delivery Service Manual Technical Support Phone 615 355 6063 option 1 Email support betterwater com To Place an Order Fax 615 355 6065 purchase orders Email orders betterwater com Phone 615 355 6063 Customer Service Phone 615 355 6063 option 2 returns Fax 615 355 6065 Email customerservice betterwater com Website www betterwater com Helpful information and forms that can be found on our website Operator amp Service Manuals Technical Service Bulletins Consumables and Replacement Parts List Brochures Order Form Return Goods Authorization Request Form This Servic
28. ngeable Although their function is the same their width and length are slightly different and the handles are shaped differently These changes are detailed in the Single Bicarb Front View and Plumbing sections below Description Plast O Matic Valve Asahi Valve 1 2 Ball Valve Red Handle PLVAS800167 PLVAS800167 A 3 4 Ball Valve Red Handle PLVAS800169 PLVAS800169 A 3 4 Ball Valve Blue Handle PLVAS800170 PLVAS800170 A 1 Ball Valve Blue Handle PLVAS800172 PLVAS800172 A 1 Ball Valve Red Handle PLVAS800174 PLVAS800174 A Mid September 2013 Fuse Change The control box fuse was changed from a 3 amp to a 2 amp fuse and moved from fusing the secondary side of the transformer to fusing the primary side of the transformer If the fuse requires changing it should be replaced with the same size fuse that the control box was built with which is specified on the face of the box oe el ELLFFS00834 ELLFFS00832 Prior to Mid September 2013 After Mid September 2013 3 amp fuse 2 amp fuse Better Water LLC rev Jan 2014 Page 6 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual SINGLE BICARB FRONT VIEW Mixer Motor EQBICB01868 902 1 2 Poly Elbow MPT x Hose Barb PLFIPO00355 Loop Service Valve 3 4 Pre July 2013 PLVAS800170 Post July 2013 PLVAS800170 A Jug Fill Valve 3 4 Pre July 2013 PLVAS800170 Post July 2013 PLVAS800170 A Service Valve 1 Pre July
29. nk Central Mix and Delivery Service Manual HOW TO OBTAIN A REPLACEMENT PART UNDER LIMITED WARRANTY a Buyer should contact the Customer Service or Technical Support Departments and request a Return Goods Authorization b Described part s will be sent with a purchase order c The returned part s will be returned to the factory for limited warranty consideration If part s are not covered under the limited warranty part s will be considered billable against the purchase order supplied WHAT IS NOT COVERED BY THIS LIMITED WARRANTY By way of example and not limitation this limited warranty does not cover Damage to or replacement of any ion exchange resin of filter media Labor or service charges for the removal and or replacement of any defective parts after the ninety 90 day period from the date of installation or sale by Better Water LLC Freight charges and travel expenses Damage from inadequate or defective wiring improper voltage improper connections or electrical service inadequate or defective plumbing water supply or water pressure or in violation of applicable building plumbing or electrical codes laws ordinances or regulations Damage from improper installation or operation including but not limited to abuse accident neglect improper maintenance freezing and fires or abnormal use Damage caused by contaminants in Buyer s water supply including hardness chlorine chloramines sulfur bacterial iron ta
30. nnin algae oil organic matter or other unusual substances if special equipment has not been installed by Better Water LLC to remove such contaminants Damage to or caused by filters membranes or other replacement parts not purchased from Better Water LLC or damage caused by modification alteration repair or service of the equipment or any of its parts by anyone other than Better Water LLC or its expressly authorized representatives Better Water LLC rev Jan 2014 Page 36 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual Better Water LLC rev Jan 2014 Page 37 of 37
31. o avoid electrical shock hazard do not operate this device when the covers or panels are removed 5 ELECTROMAGNETIC INTERFERENCE This device can create and radiate radio frequency energy and may cause harmful interference if not installed according to the manufacturer s instructions CAUTIONS 1 When used as a medical device federal law restricts this device to sale by or on the authority of a physician Per CFR 801 109 b 1 2 Improper operation of this device could result in a low or no flow alarm on the dialysis machines 3 Misuse or improper operation of this device will void any warranty 4 Where water is mentioned unless otherwise noted it must be AAMI standard quality water 5 Electrical and plumbing connections must adhere to local statutes and any facility codes Connect this device to a proper ground connection in accordance with the National Electrical Code Do not remove the ground wire or ground plug Do not use an extension cord with this device 6 Do not remove any Caution Warning or any other descriptive labels from the device 7 Do not operate this device in an explosive environment or in the presence of flammable materials Do not use this device to store mix or transfer flammable liquids 8 Movement or vibrations during shipment may cause connections to loosen 9 Do not operate this unit in an environment where temperatures may be below 50 F or above 90 F 10 This device should not be
32. oop 3 4 Schedule 80 PVC ReturnPort ie Loop from loop to ae A Feed Fill Port to tank Rinse Down Hose Connection RO Inlet Water Line 1 bb Stainless Tee Bicarb Feed Connection to Loop 3 4 Schedule 80 PVC Bicarb Feed Hose from Bicarb Feed Valve to Loop valve on back of tank not shown Reference DWG 3489 Better Water LLC rev Jan 2014 Page 22 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual PLUMBING HEADER Part EQASSYBCB01859 Loop Return 3 4 PVC Sch80 Union PLFIS800134 3 4 PVC Sch80 Union PLFIS800134 Disinfect Valve 1 2 Pre July 2013 PLVAS800167 Post July 2013 PLVAS800167 A Sample Port PLVAS800970 Check Valve 1 2 SS amman wwen m al 1 4 Poly Nipple y PLFIPO00304 eee i 1 2 Fill Hose Tank Fill Solenoid Valve 5 Nipple PLVAS801819 PLFIPO00298 Bicarb Return Valve 3 4 Pre July 2013 PLVAS800170 Post July 2013 PLVAS800170 A 4 T il PX ee ie oe N 1 2 Rinse Down Hose peer Fitting whe z ARR ee nar an a WRA S Pe RI bs eel pee a3 ba Teorey ee Ree aT Sere pe ransti A ia K i g Y f _ be ss a PLFINY00338 h l a Y i a _ 3 4 90 Poly Nipple PLFIPO00351 3 4 PVC Sch80 Female Adapter PLFIS800093 Return To Drain Valve 3 4 ee Pre July 2013 PLVAS800169 ee Post July 2013 PLVAS800169 A een 3 4 90 Poly 1 2 Rinse Down Nipple Hose Valve PLFI
33. ose Clamp amp Bulkhead 3 4 Hose Style 5000 Length from tank to header PLHOST00315 Clamp Lined Worm Drive Hose x2 one for each end of hose PLHOCLO02 902 3 4 Poly Elbow MPT x Hose Barb PLFIPO00351 3 4 Poly Bulkhead PLFIPO00308 3 4 Poly Bulkhead PLFIPO00308 S8 Male Adapter SxT PLFIS800098 3 4 Sch 80 Pipe 32 length PLPIS800044 Underside of Lid Inside Tank View Showing Bulkhead Adapter and Drop Down Tube Better Water LLC rev Jan 2014 Page 14 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual FILL INLET CONNECTIONS 1 2 Hose Style 5000 60 gallon 19 100 gallon 25 PLHOST00322 CP a S E 902 1 2 Poly Elbow MPT x Hose Barb PLFIPO00355 Clamp Lined Worm Drive Hose PLHOCLOO1 PLFIPO01848 Close Up of Tank Showing Hose Clamp amp Bulkhead Inside the Tank Connection to the Bulkhead can be one of two configurations both of which are shipped with the Bicarb in the Accessories Box 902 1 2 Poly Elbow Flow Control 2 0 GPM 902 1 2 Poly Elbow MPT x Hose Barb PVC Sch 80 MPT x Hose Barb PLFIPO02070 PLFCS802001 PLFIPO00355 Better Water LLC rev Jan 2014 Page 15 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual VERIFYING FLOAT SWITCH FUNCTIONALITY Float Switches were used on Bicarbs produced prior to January 2009 Bicarbs produced from January 2009 use the High and Low
34. the dialysis machines to go into a Low Pressure alarm condition BICARB FLOW DIAGRAM BICARB RETURN FROM FLOOR BICARB FEEL TO FLOOR DISINFECT VALVE B 21 LOOP RETURN fe SAMPLE PORT E CHECK LOOP RETURN Bae VALVE VALVE B 6 n SOLENOID VALVE CHECK VALVE RETURN TO DRAIN VALVE RINSE DOWN VALVE B 16 RO WATER IN RO WATER OUT FLOW j FLOW 5 JUG FILL Hen gnur 2 VALVE LOOF ae b 4 reeks TR a Ea SERVICE 4J _ DRAIN VALVE hS AT VALVE D TO DRAIN i PUE o BI CARB TANK Reference DWG 3742 Better Water LLC rev Jan 2014 Page 25 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual CONTROL BOX Front View Part EQASSYBCB01854 Functions amp Part Numbers Pump Indicator Light This Light will be illuminated when stribu i Mixer Control Switch the distribution Pump is running aie RA Indicator Light complete mixer motor ON and OFF ped piete ELPWSW01132 Replacement Bulb ELLPLS01896 TANK ALARM Switch This switch monitors the Low Level Alarm ELPWSW01132 FUSE HOLDER FUSE This fuse will protect the entire Control Box Fuse Holder ELOTEL00833 Pre mid Sept 2013 Replacement Fuse 3amp ELLFFS00834 T Post mid Sept 2013 Replacement Fuse 2amp ELLFFS80032 KEYED DISINFECT Switch This switch must be in the ON position when disinfecting This will override the high level sensors so tanks c
35. used for purposes outside the device s stated applications specifications or limitations Better Water LLC rev Jan 2014 Page 3 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual MODELS There are two models of the Dual Bicarb unit the 60 gallon and the 100 gallon The operation service and replacement parts of these two units are the same with the only difference being the size of the tanks i us Single 100 Gallon Bicarb Unit Part Single 60 Gallon Bicarb Unit Part EQASSY60BC 1TNK EQASSY100BC 1TNK IMPORTANT INFORMATION FOR SUPPORT Adhered to the front of each Bicarb unit is a label containing important information relating to the specific Bicarb unit and details both the Model and Serial Number Both of these pieces of information are very important in obtaining support determining warranty and properly servicing the Bicarb unit Please have this information available if you contact Technical Support Better Water LLC _ 698 Swan Drive a i Smyrna TN 37167 I Model EQA rT 55 odel EQASSY60BC 1TNK 13 Year a i d a E _ I Serial BC1301013 a 01 Month W The first four numbers in the serial number denote the year and month the device was manufactured n the example above the Single 60 Gallon Bicarb was produced in 2013 in the month of January Better Water LLC rev Jan 2014 Page 4 of 37 Single Bicarb Tan
36. x B ss bg ae a oo Smee Fr Piezo Alarm When activated the Piezo provides an audible alarm when the level in the tank reaches the Low Level Sensor Receptacles x3 These provide a place to plug in from the back the Distribution Pump and both Mixers ELSAPZ01097 ELHBRE01852 Better Water LLC rev Jan 2014 Page 27 of 37 Single Bicarb Tank Central Mix and Delivery Service Manual CONTROL BOX Inside Box View Part EQASSYBCB01854 Functions amp Part Numbers For Models Produced before January 2005 Transformer This will convert the incoming 120 vac power to 24 vac to operate the timers and relays that control all operations of the unit Timer Controls the length of time that the Mixers will run Receptacles x3 These provide a place to plug in from the back the Distribution Pump and both Mixers Timer Base ELIDRLO1839 ELHBRE01852 ELMTTRO01380 Timer ELIDRLO1840 Contactor Provides overload protection for the Distribution Pump g 20912 ELSICN003 Piezo Alarm When activated the Piezo provides an audible alarm when the level in the tank reaches the Low Level Sensor Thermal ELSAPZ01097 muasi Overload Latching Relay Provides Relay x2 High Level Shut thermal Controls High and off and