GenPac GE-970 Service Manual - Terrafirma Equipment Sales
Contents
1. PARTS LIST ITEM PART NO QTY NO DESCRIPTION 1 1 110878 BASE PLATE 2 4 660851 HEX HEAD CAP SCREW 3 8 331900 HARDENED FLAT WASHER 4 4 441900 HEX NUT 5 8 110851 HEX HEAD CAP SCREW 7 1 779819 90 GREASE FITTING 8 1 000851 COVER PLATE 9 2 770850 ROLLER BEARING 10 2 880850 BEARING HOUSING 11 1 770870 ECCENTRIC 12 1 220878 HOUSING 13 4 991974 RUBBER MOUNT 14 32 001973 HEX HEAD CAP SCREW 15 32 770878 ELASTIC STOP NUT 16 1 990877 ADAPTOR PLATE 17 1 770877 HYDRAULIC MOTOR 18 2 110879 SCREW 19 1 770871 90 GREASE FITTING 20 1 440878 TOP MOUNTING FRAME 21 1 880877 NAME PLATE 22 4 441703 DRIVE SCREW 26 1 115653 ELBOW 27 1 440399 HOSE ASSEMBLY 28 1 220879 HOSE ASSEMBLY 29 2 330879 90 BULKHEAD UNION 30 2 995682 HOSE ASSEMBLY 31 2 660872 MALE CONNECTOR WITH TEST PORT 32 2 666756 HEX HEAD PIPE PLUG 36 2 111927 LUBRIFICATION DECAL GENTEC EQUIPMENT INC Fax 613 833 0584 E mail gentecequip rogers com www gentecequipment com
2. few hours use after torquing Limit the reuses of fasteners to two or three times www gentecequipment com 9 3 BEARING REPLACEMENT USE ONLY GENTEC SUPPLIED BEARINGS THEY ARE SPECIFICALLY SELECTED FOR THE APPLICATION Step 1 Remove bearing housing assembly from the main housing Step 2 Press the inner race of the bearing from the back side of the bearing housing Step 3 Grease lubricate the replacement bearing before installing Work grease into all cavities of one side until it appears on the opposite side Step 4 The bearing is a press fit in the housing and must be forced in by pressing on the outer race only Step 5 After complete assembly grease an additional 20 shots to fill bearing cavity 9 4 LUBRIFICATION Under normal operating conditions bearings should be lubricated every 2 running hours Extreme conditions such as high temperature require more frequent lubrication Approximately 10 shots per bearing is recommended Use these greases or equivalent Shell Oil Alvania EP2 Mobile Oil Co Mobilux EP2 Texaco Inc RB2 CHECK VALVE INSTALLATION FOR GENPAC GE 870 amp GE 970 SUPPLY VALVE PRESSURE LINE 2000SI MAX CHECK VALVE 3 4 PORTS 5 PSI CRACKING PRESSURE RETURN LINE 100 PSI MAX Ez HYDRAULIC TANK www gentecequipment com MODEL GE 970 GENPAC BASIC COMPONENTS www gentecequipment com MODEL GE 970 GENPAC PART NUMBER 0878
3. Gentec www gentecequipment com MODEL GE 970 Boom Mounted Compactor Driver GENPAC INSTALLATION OPERATING SERVICE AND SAFETY INSTRUCTIONS PARTS LIST 1 0 INTRODUCTION The Genpac GE 970 is a boom mounted hydraulic vibrating plate compactor and driver Primarily it 1s used for soil compaction and sheet driving by construction and industry CAUTION Instructions given with this symbol are for personal safety and full service life of the compactor Follow them carefully Operation or service other than in accordance with these instructions may subject the compactor to conditions beyond the design capability Improper operation or servicing may result in failure or personal injury Read this manual thoroughly before operating or maintaining the unit 2 0 DESCRIPTION The Genpac GE 970 is a high energy impulse tool utilizing three basic forces HIGH IMPULSE FORCE of the eccentric turning at high r p m not only produces impulse force but also when properly controlled gives impact force The 2000 r p m frequency produces VIBRATION for maximum effectiveness in the compaction of granular material DOWN PRESSURE of the backhoe or other carrier provides a high static pressure to develop the resistance necessary for compaction The greater the down pressure or resistance the higher the developed hydraulic pressure 3 0 SPECIFICATIONS U S Metric Impulse Force 14 000
4. Ibs 6363 kg Cycles Per Minute 2 000 Hydraulic Flow Required 17 20 g p m 64 76 I p m Operating Pressure 1 500 2 000 p s i 103 138 bar Base plate Dimensions 24 in x 34 in 6 1 2 cm X 86 cm Compaction Area 4 7 sq ft 44 m Lift Compaction Weight 800 Ibs 409 kg Height 32 in 81 cm Width 24 in 61 cm Boom Pin Diameter 1 3 4 in 38 1 mm Bracket Spacing 11 1 4 in 260 mm Hose Size Pressure Line 3 4 in 19 mm Return Line 3 4 in 19 mm www gentecequipment com 4 0 PRINCIPLE OF OPERATION The Genpac GE 970 consists of the following major subassemblies Live Frame The vibration generator motor bearings eccentric mass and housing mounted to the base plate Suspension System Rubber mounts which suspend stabilize and isolate the live frame Mountain Frame Adapts the suspension system of the live frame to the boon of the carrier unit 5 0 INSTALLATION ON CARRIERS The Model GE 970 Genpac is designed for installation on rubber tire backhoe loaders and excavators As a rule productivity increases as the machine weight increases Pressure relief valve should be set no higher than 2 500 p s i Hydraulic flow should never exceed 20 g p m at 2 000 p s i 6 0 GENERAL CONSTRUCTION SAFETY The standard procedures that are expected and or required of those working in construction should be followed including location of existing underground servi
5. ce lines establishing pedestrian barriers and personal protective equipment etc In addition comply with the recommendations of the occupational safety and health standards of the U S Department of Labor For OSHA construction guidelines contact your local federal government office bookstore or write U S Government Printing Office Superintendent of Documents Washington D C 20402 Ask for Construction Industry OSHA Safety and Health Standards 29 CFR 1926 1910 www gentecequipment com 7 0 SAFETY PRECAUTIONS Ro lt lt lt RE SS Stay clear while in operation Never activate the compactor unless the operator is in full control of the machine Never operate an excavator or backhoe except from the operators seat Do not operate the compactor above 180 F hydraulic oil temperature Do not operate the compactor above 1 500 2000 p s i 103 138 bar operating pressure Use only Gentec replacement parts All fasteners must be retorqued every day for the first twenty hours of use Make frequent visual inspections of fasteners boom pins hose fittings ect Use caution when torquing fasteners A previously overstressed part may fail Do not overtorque fasteners Adhere to specifications only Install all hydraulic hoses outside of cab The major Genpac components are heavy Never mount the Genpac on a machine that cannot adequately handle the weight 900 Ibs or m
6. ore When installing or removing keep hands and fingers clear of mounting pin holes and linkage Instruct operator to touch controls only when instructed Be caution of possible flying metal particles when striking any hardened surfaces with a hand held tool Always protect your eyes when driving boom pins etc Wear ear protection if conditions warrant Consult OSHA regulations Properly inspect and maintain all reciprocating parts and shock absorbers Operate mindful of the effect vibration may have on trench walls Never operate un a trench with construction workers nearby Never service in an open trench or other unsare area As with all hydraulic tools clean up oil spills www gentecequipment com 8 0 OPERATION The Model GE 970 will achieve compaction density of 95 Proctor with granular material in 2 to 4 ft lifts and up to 3 ft lifts in clay material Moisture content near optimum increases production rate Best results are usually obtained with two passes For the initial pass time for each position of the base plate is only as long as visible compaction is apparent usually 10 to 15 seconds The second pass should be with greater down pressure smoothing or ironing as required Do not bottom mounting frame arms on base plate The Model GE 970 is also a very effective sheet or pile driver In moist sand or clay straight down pressure producing vibration perpendicular to the sheeting is sufficient If excessive driving re
7. sistance is encountered as in dry or rocky material for example position the base plate 1 4 to 1 3 from the edge of the sheeting The resulting slapping or impacting of the base plate will improve driving Hydraulic pressure during operation is that which is developed by the work resistance When the compactor is in midair the pressure will be approximately 500 p s i and when compacting will rise between that pressure and relief setting NOTE IMPORTANT CONSIDERATIONS DO NOT BOTTOM OUT MOUNTING FRAME ON BASE PLATE DO NOT OPERATE THE COMPACTOR WITHOUT BASE PLATE 9 0 SERVICE AND MAINTENANCE 9 1 GENERAL GUIDELINES Use standard mechanical technical techniques to disassemble and assemble the Genpac Observe all safety practices Keep the hoses in a loop between motor and top mounting bracket Angle fittings to maintain 1 inch hose clearance from vertical sides of mounting bracket Keep return line restrictions to a minimum and maintain clear oil Follow the backhoe manufacturer s recommendations on hydraulic system maintenance Torque 1 Clean fasteners and mating surfaces and apply grease to threads and washer faces 2 Draw the surfaces snug tight by exerting medium effort with wrench of normal length 3 Preload the fastener by turning the screw head or nut an additional 1 3 turn 2 flats this should require a cheater bar Periodically check fastener tightness especially during the first