Home

1 Safety instructions

image

Contents

1. FIND gt gt lt gt gt Num END Enter search Search for Show the Show the Search for Exit Info Alibi criteria next data recordof datarecordof data record and return to matching the weighing the weighing with known normal mode data record carried out carried out data record starting with directly directly number oldest beforehand afterwards Fast search with entry of data record number 1 Press gt Num key 2 Enter number of data record to be searched for and confirm with lt AlibiMemory 690 now searches for the desired data record Notes e The search may take up to 10 seconds e f no data record with the entered number is found the message NO MATCHING DATA RECORD appears Search with other search criteria gt Press FIND key The function keys are given the following assignment DATE TIME NET TARE START END Enter Enter Enter net Enter Start search Terminate date as time as value as tare value as with entered search search search search search search criterion criterion criterion criterion criteria All offered search criteria can be combined with each other The entered search criteria are shown in the display in clear text This enables you to search for a find a specific weighing Enter date gt Press DATE key and enter complete date in DD MM YY form Enter time gt Press TIME key and enter desired time in one of following formats Fo
2. TEST Test function for communication testing All characters received over the interface are shown in the display Simple character strings can be sent if desired 41 0 Parameters of the 1 0 module Some parameters are not editable dependent on the program SWITCH ON OFF Switches the function of this driver on or off TEST Test function for testing the 4 I O module The display shows the signal over inputs 1 4 Outputs 1 4 can be switched on or off using keys 1 4 Important Please ensure that no system functions are activated inadvertently 28 Operating instructions 22012856 05 06 IND690 Sys Settings in the master mode RELAY BOX 8 SWITCH ON OFF Switches the function of this driver on or off I O TEST Tests function and state of inputs outputs of 1 or 2 connected relay boxes 8 690 When an input or output is set high its number is shown in the display When an input or output is not set low is shown in the display Setting outputs Switch outputs using keys 1 to 8 of the numeric keypad Setting inputs Inputs can be set by connecting a voltage supply 24 V for example Multiple relay box 8 690 Switch over to further relay box 8 690 using the ENTER key Comment The relay box 8 690 corresponds with the BIU Binary Interface Unit For additional information see the operating and installation instructions for the 505918A Binary Interface Unit
3. TCP IP Parameters of the TCP IP driver which parameterises the Ethernet 690 interface SET TERMINAL IP This configuration item is only displayed if the Ethernet 690 interface has not been ADDRESS configured correctly yet refer to the following page NETWORK TERMINAL Enter the IP address IP ADDRESS SUBNET MASK Enter the net mask GATEWAY Enter the gateway address PING Enter a ping to another IP address MAC ADDRESS Display the Mac address CONNECTION VP 1 XXXXXXXX Virtual Port 1 2 or 3 with program specific designation xxxxxxxx Other settings NEES OS SWITCH ON OFF Switches the function of the driver on or off VP3 XXXXXXXX CLIENT SERVER Display whether the CLIENT or SERVER operating mode is selected PORT Set the port number of the connection COMPUTER IP Enter the IP address of the host computer Only possible in the CLIENT mode TEST Test function Operating instructions 22012856 05 06 29 Settings in the master mode IND690 Sys 30 Set terminal IP address 1 Enter the permissible IP address in order to carry out the basic configuration of the Ethernet 690 interface 2 Start a browser on a computer in the same network segment for example Microsoft Internet Explorer 3 Enter the IP address of the Ethernet 690 interface The following login prompt is displayed I Com Server Highspeed Microsoft Internet Fx Dike eabeten anahe pavorten Diras 2 Ml reosi7e 21 83 7 Com Server 4 If appropriate enter
4. sania Go METTL IND690 Sys weighing terminals 5 amp g z 8 OE Doe OOOO www mt com support ServiceXXL Tailored Services Congratulations on choosing the quality and precision of METTLER TOLEDO Proper use according to these instructions and regular calibration and maintenance by our factory trained service team ensure dependable and accurate operation protecting your investment Contact us about a ServiceXXL agreement tailored to your needs and budget We invite you to register your product at www mt com productregistration so we can contact you about enhancements updates and important notifications concerning your product IND690 Sys Contents Contents Page 1 Safety instructions ccccccceeeeeeeeeeeeeeeeeeeneeeeeeseeeseneeeeseeeeeeeeenes 4 1 1 Safety instructions for IND690XX SYS eree 4 1 2 Safety instructions for IND690 SyS eee 5 2 Introduction and COMMISSIONING c eececeseeeeeeeeeeeeeeeeeeeeeeseeees 6 2 1 Documentation te2Airc sess niactdt aurnanden tant heMentoters of nonatestaedeeeeceuuiaes 6 2 2 AD PLICATIONS cenger a liven fia dbevadinaiiadk AA 6 2 3 IND690 xx Sys weighing terminal 7 2 4 Ee naO PEE En EEE EEEE T E tan aud lag aad agains 9 2 5 DISPOSG sees tacsttus raetaee helt da e E tah E N 9 3 Basie FUNCIONS sccidicdaniesescwedietstuavececusceayureevesuets deadecceeeaseunaadden tenets 10 3 1
5. 5 1 TERMINAL O K RESET TERMINAL VOTARE O K OK TERMINAL PAC SCALE INTERFACES SERVICE gt lt Overview of the master mode In the master mode you adapt the IND690 Sys weighing terminal to meet your needs Depending on the configuration the master mode is divided into 4 or 5 master mode blocks which are in turn divided into further blocks PAC INTERFACES SERVICE O K O K O K t RESET WEIGHING _ VIBRATION SCALE PROC ADAPT ADAPTER For system settings such as entering the date and time or loading permanent texts see section 5 3 To set application specific parameters To select one of the connected weighing platforms For each selected weighing platform the parameters are then set which concern the weight value e g stability detector unit etc see section 5 4 To select an interface The communication parameters are then set for each interface see section 5 5 For configuring the weighing platform s On IDNet weighing platforms only for METTLER TOLEDO service technicians On weighing platforms with an analog signal output see service manual A D converter Point ME 22004256 Operating instructions 22012856 05 06 19 Settings in the master mode IND690 Sys 5 2 5 2 1 5 2 2 Example 5 2 3 Example 20 Operating the master mode Enter the master mode 1 Press MODE key If the current function keys assignment does no
6. for printing for data exchange with a computer for connecting a barcode reader for control e g of valves or flaps for connecting reference scales for connecting an external keypad for wireless data exchange via bluetooth or WLAN 2 3 IND690 xx Sys weighing terminal 2 3 1 Display INFO MODE Ae aia NET 5 z 6 Operating instructions 22012856 05 06 7 Weight display BIG WEIGHT with sign and decimal point Stability monitor lights up until the weighing platform has levelled out then the weight unit appears here Range display for multi range weighing platforms Number of the weighing platform shows the weighting platform just selected Symbol for identifying weight values in the second unit or in a higher resolution NET symbol for marking net weight values Assignment of the function keys Introduction and commissioning IND690 Sys 2 3 2 Keypad aS OOO H lt gt N 3 oda A WN 10 11 12 0000 0L Ex AA O Cae 4 5 67 8 9 10 CODE A CODE F keys enter identification data BACK key return to the previous input mask CANCEL key cancel input SCALE key select scale ZERO SET key set scale to zero test scale Function keys F1 F6 the current assignment is shown in the display above the key TARA key fare scale TARE SPECIFICATION key enter known tare va
7. 12 T Tare 11 37 TCP IP client 29 Technical data 37 Test weighing platform 14 Time 23 37 V Vibration adapter 25 37 Ww Weighing 12 Weighing functions 37 Weighing process adapter 25 37 What to do if 34 Operating instructions 22012856 05 06 22012856 Subject fo technical changes Mettler Toledo Albstadt GmbH 05 06 Printed in Germany 22012856 Mettler Toledo Albstadt GmbH D 72458 Albstadt Tel 49 7431 14 O Fax 49 7431 14 232 Internet http Awww mt com
8. CC Country code e g DE Germany AA Software type e g OO Base XXXXXXXXXX Order No VW Software version DD MM YYYY Date of manufacture day month year Operating instructions 22012856 05 06 13 Additional functions IND690 Sys 4 Additional functions The assignment of the 6 function keys of the IND690 Sys weighing terminal differs depending on the weighing task The current assignment is shown above the function keys The cursor keys lt or gt can then be used to switch fo other function key assignments Independent of the customer specific application software the IND690 Sys has the following additional functions OFF INFO MODE Switch off Display Activate IND690 Sys information master mode see 4 2 see Chapter 5 4 1 Display ID code and test weighing platform Each time the weighing platform configuration is changed the ID code counter is increased by 1 On certified weighing platforms the displayed ID code must match the ID code on the ID code sticker otherwise the calibration is no longer valid Display ID code gt Press and hold until IDENTCODE appears in the display Test weighing platform gt Press again The connected weighing platform is checked The display shows CHECK SCALE and then SCALE IS OK after completing the test Note If weighing platform is defective display shows SCALE ERROR 14 Operating instructions 22012856 05 06 Additional functions 4
9. connected gt Inform METTLER TOLEDO Customer properly Service e Not all scales connected gt Connect weighing platforms and or connect mating connectors to available weighing platform connections Operating instructions 22012856 05 06 35 What to do if IND690 Sys Error Message Possible causes Rectification SCALE NO ERROR e Error in weighing cell e Two or more connected weighing platforms have identical scale number gt Repeat test gt If message appears again Inform METTLER TOLEDO Customer Service Inform METTLER TOLEDO Customer Service NO CONTACT TO FTP SERVER e Network connection faulty e FTP server program not installed on external computer gt Rectify network connection problem gt Install FTP server program WRONG CODE e Incorrect personal code e Incorrect information in FTP SECURITY or FTP FILE gt Enter correct personal code gt Enter permissible values for username password drive directory and file name DATABASE INIT ERROR e Database could not be initialised Inform METTLER TOLEDO Customer Service 36 Operating instructions 22012856 05 06 IND690 Sys Technical data 7 Technical data Weighing functions Tare compensation At the press of a button or automatically up to maximum load subtractive Tare target value e For single range scales over entire weighing range su
10. in the following Settings in the TERMINAL master mode block RESET TERMINAL Reset all terminal functions to the factory setting e Resets the password MINIMUM to the factory setting 2234 e LANGUAGE german e LAYOUT EXT KEYBOARD Germany LANGUAGE Select dialog language Possible setting English Deutsch Fran ais Nederlands Italiano Espanol Polski Russian Slovakian Portuguese Hungarian Slovenian Czech Croatian LAYOUT EXT Select keyboard layout of connected external keyboard KEYBOARD Possible settings German French Dutch Italian Spanish Finnish British US International 22 Operating instructions 22012856 05 06 IND690 Sys Settings in the master mode DATE TIME Enter date and time e Enter DATE in European notation Day Month Year e Enter TIME in European notation 24 Hours Minutes Seconds Comments e Enter single place numbers with a preceding zero e The clock continues to run after the terminal is switched off PERSONAL CODE Codes for entering various master mode menus Enter codes with a maximum of 8 alphanumeric characters MINIMUM Access fo master mode GENERAL Access fo all personal codes PAC Access to the PAC RESET PAC and PAC ERROR INFO menus PAC DATAB Access to the PAC DATABASE menu PAC APPL Access to the PAC APPLICATION menu INTERFACE Access to all parameters in the INTERFAC
11. the password The Com server can now be configured Configuration of the Com server 1 Set the Com server to the factory setting To do so click the following command buttons Login gt OK gt Logout gt Restore Default 2 Deactivate the C Addr mode To do so click the following command buttons Login gt OK gt SETUP Port O High Speed Serial gt TCP IP Mode gt TCP Client gt Client C Addr gt Send gt Back gt Logout gt Save 3 Activate the Serial Socket Interface To do so click the following command buttons Login gt OK gt SETUP Port O High Speed Serial gt TCP IP Mode gt Serial Socket Interface gt Serial Protocol gt Serial Coding X gt Send gt Back gt Logout gt Save 4 Switch the IND690 Sys off and then on again The further configuration can now be carried out Note If no IP address can be entered Check whether the Ethernet 690 interface is installed correctly If appropriate call the METTLER TOLEDO Service Operating instructions 22012856 05 06 IND690 Sys Settings in the master mode FTP CLIENT Parameters of the FTP client driver which parameterises the Ethernet ID7 interface as an FTP client SWITCH ON OFF Switches the function of this driver on or off IP ADDRESS Network IP address of the IND690 Sys This address must be assigned by IT personnel under the administrator It must be unique within
12. 2 Recall information On the weighing terminal memory contents and system information can be recalled 1 Press INFO key Then the following function key assignment appears DATE TARE SCALE ALIBI END VERS Display date Display tare Call up the Recall content Exit Display and time weight data of the of alibi information version current scale memory see mask numbers of Version section 4 4 installed max load This selection software ID code etc only appears modules when Alibi Memory 690 is installed W amp M ERROR COM Display Fault Calling up the checksum of Eventmemory settings of the the software display interfaces relevant to calibration The correct checksum is documented in the calibra tion approval 2 Select desired information The information is displayed for about 5 seconds then the weighing terminal changes to the weighing mode again Note When several values are displayed the IND690 Sys automatically changes to the next value after approx 5 seconds Operating instructions 22012856 05 06 15 Additional functions IND690 Sys 4 3 4 4 Working with external keypad If the weighing terminal is equipped with the interface PS2 690 an external keyboard can be connected so that alphanumerical values can be entered conveniently In addition to the alpha and numerical keys the following additional scale functions can also be operated with the external A
13. 90xx Sys weighing terminal fulfils Device category 3 and is approved for operation in Zone 2 gases and Zone 22 dusts hazardous areas There is an increased risk of injury and damage when the IND690xx Sys weighing terminal is used in a potentially explosive atmosphere Special care must be taken when working in such hazardous areas The code of practice is oriented to the Safe Distribution concept drawn up by METTLER TOLEDO A A The weighing terminal accompanying weighing platforms and accessories may only be installed maintained and repaired by authorised METTLER TOLEDO service personnel The mains connection may only be connected or disconnected by the owner s electrician For the exact specification please refer to the statement of conformity No modifications may be made to the terminal and no repair work may be performed on the modules Any weighing platform or system modules that are used must comply with the specifications contained in the installation instructions Non compliant equipment jeopardizes the safety of the system cancels the Ex approval and renders any warranty or product liability claims null and void The cable glands must be tightened so that a strain relief of gt 20 N per mm cable diameter is ensured When connecting external devices always observe the maximum permissible connected loads see installation information It must be ensured that no voltages are fed into the IND690xx Sys than it itself
14. E menus the test functions are freely accessible OPTION 1 Program dependent OPTION 2 OPTION 3 Comment If only zeros are entered the password is not used Operating instructions 22012856 05 06 23 Settings in the master mode IND690 Sys 5 4 SCALE master mode block In the first block the weighing platform is selected SCALE 1 SCALE 3 The other setting possibilities are the same for all connected weighing platforms 5 4 1 Overview of the SCALE master mode block In the SCALE master mode block the following settings for the weight can be carried out RESET SCALE WEIGHING PROC UNIVERSAL STATIC ADAPT WEIGHING WEIGHING ees VIBRATION AVERAGE EXTREME IDEAL ADAPTER CONDITIONS CONDITIONS CONDITIONS STABILITY _ _ AUTOZERO AUTOZERO ON AUTOZERO OFF RESTART RESTART OFF RESTART ON DISPLAY UPDATE 6 UPS 10 UPS be Legend Blocks highlighted in grey are described in detail in the following e Factory settings are printed in bold print e Blocks which only appear under certain conditions have a dotted outline 24 Operating instructions 22012856 05 06 IND690 Sys Settings in the master mode 5 4 2 Settings in the SCALE master mode block RESET SCALE Reset weighing platform to factory setting WEIGHING PROC ADAPT universal weighing VIBRATION ADAPTER average conditions STABILITY DETECTOR ASD 2 AUTOZERO on RESTART off WEIGHING PROC ADAPT Adapt weighing platform to weighing
15. K MFIl keypad Function for IND690 Sys ay Function for IND690 Sys eae Function key F1 Fl CODE A key Shift F1 Function key F2 F2 CODE B key Shift F2 Function key F3 F3 CODE C key Shift F3 Function key F4 F4 CODE D key Shift F4 Function key F5 F5 CODE E key Shift F5 Function key F6 F6 CODE F key Shift F6 key F9 key Shift F9 key F10 key Shift F10 ETO key F11 679 key Shift F11 key F12 Key Shift F12 Note The language of your external keyboard can be set in the master mode block LAYOUT EXT KEYBOARD see page 22 Recall data from Alibi memory With the AlibiMemory 690 memory module you can fulfill your recording obligations in certified operation without having to archive paper AlibiMemory 690 automatically assigns every weighing operation a consecutive data record number that also appears on the printout saves the net and tare value and also the date and the time The AlibiMemory 690 operates according to the principle of a ring memory When the capacity limit of 675500 data records is reached the oldest data record is deleted and overwritten with data from the latest weighing By entering suitable search criteria you can quickly access the data of a very specific weighing Operating instructions 22012856 05 06 IND690 Sys Additional functions 4 4 1 4 4 2 4 4 3 Initiate gt Press INFO ALIBI key sequence The function keys change to the following assignment
16. Prevent damage to the weighing terminal Hairline cracks in the keyboard membrane are also considered damage If the IND690xx Sys weighing terminal accompanying weighing platforms or accessories are damaged Switch off weighing terminal Separate the weighing terminal from the mains in accordance with the applicable regulations Secure the weighing terminal against accidental start up The IND690xx Sys panel unit does not comply with any freedom from leaks rating Therefore the installer is responsible for compliance with the freedom from leaks rating e g at control cabinet installation The respective national standards furthermore have to be observed At least a freedom from leaks rating IP54 is required in hazardous areas Safety instructions for IND690 Sys A A Do not operate the IND690 Sys weighing terminal in hazardous areas We have special suitable scales in our range of products for hazardous areas Ensure that the power socket outlet for the IND690 Sys weighing terminal is earthed and easily accessible so that it can be de energised rapidly in emergen cies Ensure that the supply voltage at the installation site lies within in the range of 100 V to 240 V The safety of the device cannot be ensured if it is not operated in accordance with these operating instructions A Only authorised personnel may open the IND690 Sys weighing terminal A The IND690 Sys weighing terminal accompanying weighing platform
17. Switching omand Offenses a A AA ia 10 3 2 Seting TO ZEO non renn 4s et Gain E E E A Sti tainl 10 3 3 KOAN EAEE A enacts Tats R 11 3 4 Weighing snara ninaa aar EN A NR O AT 12 3 5 Working with several weighing platforms 12 3 6 Displaying Versions een eien e Seis Cit ales oles taal lanes 13 4 Additional FUNCTIONS cceceeeeeeeeeeeeeeeeeeeeeceeeeeeeeeeeeeeseneeeneeeeets 14 4 Display ID code and test weighing platform cceceeeeeeeeeeeeteeeees 14 4 2 Recall information serraria asa eliatecta adie uinwencavatan tities a 15 4 3 Working with external keypad eere 16 4 4 Recall data from Alibi MEMOTSY 0 00 0 eect etetttt ttt et tte 16 5 Settings in the master mode sseeeeeeeeeeesseeeeeeeeeeeeeeeeeeeneeeees 19 5 1 Overview of the master Mode errereen 19 5 2 Operating the master mode rrie e rreri ereere 20 5 3 TERMINAL master mode block 22 5 4 SCALE master mode blOCK u rirerire ste rontcvendaaandet3 24 5 5 INTERFACE master mode block erreren 27 6 E C lise E arsseessereececensesueceneustewereevenees 34 7 Technical data assssssennnnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 37 8 LINDO Xs crsstecceserveacparteansacuost eo tivenuptreappenanverecaeesenermtnneatiaaetiemnnatens 38 Operating instructions 22012856 05 06 3 Safety instructions IND690 Sys 1 Safety instructions 1 1 Competence Ex approval Safety instructions for IND690xx Sys The explosion protected IND6
18. am is running To do so click the following command buttons Login gt OK gt SETUP Port O High Speed Serial gt TCP IP Mode gt FTP Client gt Server Port 21 00021 gt Server IP XXX XXX XXX XXX gt Auto FTP Inactive Timeout 30 gt Protocol Char 3 gt Send gt Back gt Logout gt Save Switch the IND690 Sys off and then on again The further configuration can now be carried out Operating instructions 22012856 05 06 IND690 Sys Settings in the master mode PROFIBUS DP Configuring Profibus DP 690 SWITCH ON OFF Switches the function of this driver on or off NODE ADDRESS Selects the desired node address from a range of 001 to 126 OPERATING MODE Possible settings 4 words 8 words TEST Test function for testing the Profibus I O values ANALOG OUTPUT Configuring the analog output SWITCH ON OFF Switches the function of this driver on or off TEST Test function for testing the analog output Entered values can range from O to 16383 Operating instructions 22012856 05 06 33 What to do if IND690 Sys 6 What to do if negative Error Message Possible causes Rectification Display dark e No line voltage gt Check power supply e Terminal switched off gt Switch on terminal e Power cable not plugged in gt Insert power plug e Momentary interference gt Switch terminal o
19. and the NET symbol 1 Place filled container on weighing platform The display shows the gross weight total weight 2 Specify tare weight or recall tare memory The display shows the net weight container content and the NET symbol Working with several weighing platforms Up to 4 weighing platforms can be connected to the IND690 Sys and up to 3 weighing platforms can be connected to the IND690xx Sys Depending on the setting in master mode only the currently active scale appears in the display serial Multi scale mode or all scales are operated at the same time parallel multi scale mode A constantly updated sum scale is also available in parallel multi scale mode Switch over weighing platform The weighing platform currently selected is shown on the terminal gt Press sa The next weighing platform is selected or gt Enter number of weighing platform and press a The desired weighing platform is selected Note The sum scale can only be operated non verifiably It is therefore identified by the symbol x Operating instructions 22012856 05 06 IND690 Sys Basic functions 3 6 Displaying versions When connected to a power supply and when restarted see Section 3 1 the versions of the IND690 Sys and the installed components are displayed Version code for the IND690 Sys with customer specific application program METTLER TOLEDO IND690 Sys IND690 0 13 CC AA XXXXXXXX WV DD MM YYYY
20. btractive e For multi range scales depending on national calibration regulations Tare indicator NET lights up with saved tare weight Setting to zero Automatic or manual Weighing process adapter 3 step adjustment to weighing sample Vibration adapter 3 step adjustment to ambient conditions Info function Displays of system functions Date and time e For printout or output via the data interface e Quariz controlled 12 or 24 hour display automatic calendar function Europe or USA format safe against power failure Operating instructions 22012856 05 06 37 Index IND690 Sys 8 Index A Additional functions 14 Alibi memory 16 Alphanumeric identifica tion 21 Alphanumeric keypad 16 Applications 6 Automatic taring 37 Autozero 10 25 B Basic functions 10 Big Weight Display 7 c Cleaning 9 D Date 23 37 Display 7 Display update 26 E Error messages 34 External keypad 16 22 F FTP Client 31 Function keys 7 14 G GA46 27 l ID code 14 Interface 4 1 O ID7 27 28 Interface connections 27 Introduction 6 IO test 29 K Keypad 8 L Language 22 38 M Master mode 19 Multi scale mode 12 P Personal code 23 R Recall information 15 Reset scale 25 Reset terminal 22 Restart 26 S Safety instructions 4 Serial RS232 CL RS422 485 28 Set zero 10 37 Stability detector 25 Switch off 10 Switch on 10 Switch over weighing plat form
21. erically Correct entry 3 3 3 3 3 4 Taring Manual taring 1 Place empty container on scale 2 Press 6T9 The tare weight is saved and the weight display set to zero The display shows the NET symbol Notes e When the weighing platform is relieved the saved tare weight is displayed with a negative sign e The weighing platform only saves one fare value Specify tare weight This function is only available when ordered expressly 1 Press Pt 2 Enter tare weight container weight and confirm with lt When weighing platform is relieved the entered tare weight is displayed with a negative sign Note The weight unit for entering the tare weight can be selected with the cursor keys lt Or gt gt Clear the entry character by character with and repeat correctly Recall currently saved tare weight The saved tare weight can be recalled at any time gt Enter INFO sequence The saved tare weight is displayed Clear tare weight gt Relieve weighing platform and tare gt Press CE Operating instructions 22012856 05 06 11 Basic functions IND690 Sys 3 4 Weighing without taring Weighing with taring Weighing with tare specification 3 5 3 5 1 Weighing gt Lay weighing sample on weighing platform Gross weight total weight is displayed 1 Place the empty container on the weighing platform and tare 2 Pour in weighing sample The display shows the net weight
22. ff and then on again Weight display unstable Restless installation location gt Adjust vibration adapter e Draft gt Block draft e Interference between load plate and or gt Rectify interference materials being weighed and environment e Power supply interference gt Check power supply Incorrect weight display Incorrect zeroing of weighing platform gt Unload weighing platform repeat Zeroing and weighing e Incorrect tare value gt Delete tare or enter correct tarevalue e Interference between load plate and or gt Rectify interference materials being weighed and environment e Weighing platform tilted gt Level out weighing platform e Incorrect weighing platform selected gt Select correct weighing platform IDENTCODE e Test cycle started gt Complete test by pressing the ZERO SET key sates e Load plate not in place gt Put load plate in place e Pre load not in place gt Load pre load e Weighing range dropped below gt Set to zero e Weighing range exceeded gt Unload weighing platform e Weighing platform locked gt Release lock SCALE ERROR e Error in weighing platform gt Test weighing platforms gt f message appears again Inform METTLER TOLEDO Customer Service SCALE OVERLOAD e Weighing range exceeded gt Unload weighing platform TOTAL IS NEGATIVE e Total weight is negative gt Unload weighing platform and set to zero TARING ERROR e Taring not possible as total weight is gt Unload weigh
23. ing platform and set to zero repeat taring 34 Operating instructions 22012856 05 06 IND690 Sys What to do if Error Message Possible causes Rectification SET TO ZERO ERROR e Zero set range exceeded gt Unload weighing platform and set to Zero SCALE IN MOTION e Weight value does not remain gt Wait until weighing platform shows constant weight value which remains constant e Restless environment gt Ensure low vibration environment gt Check setting of vibration adapter gt f message appears again Inform METTLER TOLEDO Customer Service SCALE NOT ZERO e Zero point has shifted gt Set to zero PRINTER OFFLINE e Printer switched off gt Switch on printer NO PAPER e No paper in printer gt Insert paper PRINTER ERROR e General printer error gt Inform METTLER TOLEDO Customer Service MEMORY CLEARED e New software in IND690 Sys all data reset to factory setting NO ALIBI MEMORY e No alibi memory found gt Inform METTLER TOLEDO Customer Service ALIBI VERSION lt 1 5 e Old version of Alibi memory 690 gt Update Alibi memory 690 END OF FILE e End of file gt Inform METTLER TOLEDO Customer Service ALIBI ERROR e Error in alibi memory gt Inform METTLER TOLEDO Customer Service ETHERNET ERROR e Ethernet card error gt Inform METTLER TOLEDO Customer Service NO SCALE FOUND e Round plug not plugged in correctly gt Insert plug correctly e Load cell cable not
24. lpha numeric entries with e Alphanumeric entries with the IND690 Sys see below e To accept the displayed value Press lt 1 Press one of the keys CODE A CODE F The functions keys are given the following assignment ABCDE FGHIJ KLMNO PQRST UVWXY Z Selection of Selection of Selection of Selection of Selection of Selection of letters A to E letters F to J letters K to O letters P to T letters U to Y letter Z or a special character 2 Select desired group of letters e g press KLMNO key 3 Select desired letter The display changes again to the above selection 4 Repeat entry in steps 2 and 3 for additional characters Note Letters and numbers can be combined as desired Emergency entrance into the master mode If a personal code has been assigned for entering the master mode and you have forgotten your code you can still enter the master mode gt Enter the character sequence C L E A R as your personal code Operating instructions 22012856 05 06 21 Settings in the master mode IND690 Sys 5 3 TERMINAL master mode block 5 3 1 LANGUAGE KEYBOARD DATE TIME Legend 5 3 2 RESET TERMINAL LAYOUT EXT PERSONAL CODE Overview of the TERMINAL master mode block In the TERMINAL master mode block you enter the following system settings ENGLISH DEUTSCH O a DEUTSCH ENGLISH Blocks highlighted in grey are described in detail
25. lues numerically CLEAR key clear entries and values ENTER key accept and transfer data Cursor keys Numeric keypad with decimal point Operating instructions 22012856 05 06 IND690 Sys Introduction and commissioning 2 4 2 5 Cleaning DANGER OF SHOCK gt Do not open the IND690 xx Sys weighing terminal to clean CAUTION gt Make sure that unused connection sockets are covered with protective caps to protect the socket contacts from moisture and dirt gt Do not use high pressure cleaners Cleaning gt Wipe off the IND690 xx Sys weighing terminal with a commercially available glass or plastic cleaner Disposal In conformance with the European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE this device may not be disposed of with domestic waste This also applies to countries outside the EU per their specific requirements gt Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment If you have any questions please contact the responsible authority or the distributor from which you purchased this device Should this device be passed on to other parties for private or professional use the content of this regulation must also be related Thank you for your contribution to environmental protection Operating instructions 22012856 05 06 9 Basic functions IND690 Sys 3 Ba
26. ly for COM2 through COMY An RS485 690 interface with relay box 8 690 must be installed on the interface connection for this purpose For other settings see Page 29 Only for COM2 through COM9 An Ethernet 690 interface must be connected to the selected interface connection For additional settings see Page 40 Only for COM2 through COM9Y An Ethernet 690 interface must be connected to the selected interface connection For additional settings see Page 43 Only for COM2 through COM9 with installed Profibus DP 690 interface For additional settings see Page 45 Only for COM2 through COM9 An Alibi Memory 690 must be installed on the selected interface connection for this purpose No further settings are required in the master mode Only for COM2 through COM9 with installed Analog Output 690 interface 27 Settings in the master mode IND690 Sys SERIAL Parameters of the standard COM interface driver for serial interfaces Some parameters are not editable dependent on the program SWITCH ON OFF Switches the function of this driver on or off MODE BAUDRATE PARITY DATABITS STOPBITS END CHARACTERS Changes interface parameters Possible settings 150 300 600 1200 2400 4800 9600 19200 Baud Possible settings Parity even Parity odd No parity Parity mark Parity space Possible settings 7 databits 8 databits Possible settings 1 stopbit 2 stopbits Possible settings End character 1 end character 2
27. on or off When RESTART ON is set the zero point and tare value remain stored after the power supply is interrupted When the weighing platform is switched on again the terminal shows the current weight Factory setting RESTART OFF DISPLAY UPDATE Set display speed of the weight display Select number of updates per second UPS Possible values 6 10 15 20 UPS Comments e This block only appears when the DISPLAY UPDATE function is supported by the connected weighing platform e The possible settings are dependent on the connected weighing platform 26 Operating instructions 22012856 05 06 IND690 Sys Settings in the master mode 5 5 INTERFACE master mode block Select the interface gt Select the interface connection in the first block connection COM1 through COM9 Possible GA46 interface types SERIAL 41 0 RELAY BOX 8 TCP IP FTP CLIENT PROFIBUS DP ALIBI MEMORY ANALOG OUTPUT Operating instructions 22012856 05 06 For connection of the GA46 GA46 W printer Data is exchanged via the RS232 690 interface The other setting possibilities are described in the operating and installation instructions GA46 An RS232 690 CL 20mA 690 RS422 690 or RS485 690 interface must be connected to the selected connection For additional settings see Page 28 Only for COM5 COM6 A 4 I 0 690 interface with relay box 4 690 must be installed on the interface connection for this purpose For other settings see Page 28 On
28. provides The interface parameters have to fulfil the standard Peripheral devices without an Ex approval may only be operating in non hazardous areas It must be ensured that no voltages are fed into the IND690xx than it itself provides In addition the maximum permissible connected loads have to be observed see installation information The interface parameters have to fulfil the standard The safety of a weighing system including the IND69Oxx Sys weighing terminal is only guaranteed when the weighing system is operated installed and maintained in accordance with the respective instructions Also comply with the following the instructions for the system modules the regulations and standards in the respective country the statutory requirement for electrical equipment installed in hazardous areas in the respective country all instructions related to safety issued by the owner Before initial start up and following service work check the explosion protected weighing system for the proper condition of all safety related parts Operating instructions 22012856 05 06 IND690 Sys Safety instructions Operation Leakages 1 2 Competence Leakages Prevent the build up of static electricity Therefore always wear suitable working clothes when operating or performing service work on the system do not rub or wipe off the keyboard surface with a dry cloth or glove Do not use protective hoods
29. rmat HH Format HH MM Format HH MM SS only the weighing at the time HH MM SS is found Operating instructions 22012856 05 06 all weighings between HH 00 00 and HH 59 59 are found all weighings between HH MM 00 and HH MM 59 are found Additional functions IND690 Sys 4 4 4 Scroll forward back Enter net tare value 1 Press NET or TARE key 2 Enter weight value and confirm with The function key assignment changes back again for selection of the search criteria Note The weight unit for entering the weight values can be selected with the cursor keys lt Or gt Start search gt Press START key AlibiMemory 690 searches for the oldest data record which meets the entered search criteria Notes e The search may take up to 10 seconds e f no data record with the entered values is found the message NO MATCHING DATE RECORD appears e f no search criterion has been entered the oldest data record is displayed Displaying data records Found data records are shown in the display DATE 02 04 98 TIME 09 25 25 NUM 000987 NET 25 000 KG TARE 100 346 KG The keys gt gt lt and gt enable you to scroll within the found data records Note When during scrolling with the key gt gt all entries of the AlibiMemory 690 have been searched through the message END OF FILE appears Operating instructions 22012856 05 06 IND690 Sys Settings in the master mode 5 Settings in the master mode
30. s and accessories may only be installed maintained and repaired by authorised METTLER TOLEDO service personnel The IND690 Sys panel unit does not comply with any freedom from leaks rating Therefore the installer is responsible for compliance with the freedom from leaks rating e g at control cabinet installation The respective national standards furthermore have to be observed Operating instructions 22012856 05 06 5 Introduction and commissioning IND690 Sys 2 introduction and commissioning 2 1 Documentation These operating instructions describe the operation of the IND690 xx Sys with the basic functions of the Sys 690 application software and all the possible interfaces Information on your customer specific Sys 690 application can be found in the corresponding operating instructions specially authored for you 2 2 Applications With the IND690 xx Sys weighing terminals the following applications are possible IND690 Sys IND690xx Sys Hazardous area Zone 2 Zone 22 4 Safe area lt gt Zone 2 Zone 22 Zone 2 Zone 22 Approved peripherals Approved weighing e g barcode reader platforms 6 Operating instructions 22012856 05 06 IND690 Sys Introduction and commissioning e Multi scale operation with up to 4 weighing platforms with IND690 Sys or up to 3 weighing platforms with IND690xx Sys including weighing platforms with an analog signal output e Up to 9 data interfaces
31. sample UNIVERSAL WEIGHING For solid bodies coarse filling or checkweighing factory setting STATIC WEIGHING For solid bodies and weighing under extreme conditions e g strong vibrations or weighing animals FINE FILLING For liquid or powdered weighing samples VIBRATION ADAPTER Adapt weighing platform to the vibration influences of the environment AVERAGE CONDITIONS Factory setting EXTREME CONDITIONS The weighing platform operates more slowly however is less sensitive e g suitable with building vibrations and vibrations at the weighing location IDEAL CONDITIONS The weighing platform operates very quickly however is very sensitive e g Suitable with very calm and stabile weighing location STABILITY DETECTOR Adapt automatic stability detector Possible settings ASD 0 Stability detector switched off only possible with non certified weighing platforms ASD 1 fast display good reproducibility ASD 2 A v factory setting ASD 3 A v ASD 4 slow display very good reproducibility AUTOZERO Switch automatic zero point correction on or off The automatic zero point correction corrects the weight of minor dirt with the weighing platform unloaded Factory setting AUTOZERO ON Operating instructions 22012856 05 06 25 Settings in the master mode IND690 Sys RESTART Switch restart function
32. sic functions 3 1 Switch on from the standby mode Switch off Switch on with restart 3 2 Manual zero set Automatic zero set Switching on and off This function is only available when ordered expressly gt Press any key The display shows a weight value based on the last tare value and Zero point gt Press function key OFF The display goes out and the IND690 Sys weighing terminal is in the standby mode The zero point and tare value remain saved Note If the function key OFF does not appear in the current assignment press the cursor key lt or gt several times if necessary until OFF is displayed 1 Relieve weighing platform 2 Press function key OFF and hold down until METTLER TOLEDO IND690 Sys appears in display Then the weight value appears The weighing platform is restarted Setting to zero Setting to zero corrects the influence of minor dirt on the load plate In the case of excessive dirt which cannot be compensated by setting to zero the display shows OUT OF RANGE 1 Relieve weighing platform 2 Press 60s The display shows 0 000 kg On certified weighing platforms the zero point of the weighing platform is automati cally corrected when the weighing platform is relieved The automatic zero set can be switched off in the master mode on noncertified weighing platforms Operating instructions 22012856 05 06 IND690 Sys Basic functions 3 3 3 3 1 3 3 2 Enter num
33. t contain MODE press the cursor keys lt or gt as offen as necessary until the MODE key appears 2 Enter personal code if configured The display shows the first master mode block TERMINAL Assignment of function keys in the master mode Assignment on the top level On the top level of the master mode the function keys are assigned as follows lt as T END OK Change to Change to next Exit level and Exitthe master Recall lower previous block block within a return to mode and level block or within a level level higher level return to confirm block normal mode selection gt Select the function by pressing the function key gt Press the END key to exit the master mode and return to the normal mode When the function keys are otherwise allocated gt Press the cursor keys lt or gt repeatedly until the function key assignment shown above appears Orientation in the master mode For improved orientation the display shows the last steps in the path of the current master mode block The upper 3 lines of the display show the following path for selecting the language TERMINAL Pah LANGUAGE Current selection ENGLISH Operating instructions 22012856 05 06 IND690 Sys Settings in the master mode 5 2 4 Enter alphanumeric identification 5 2 5 Entries in the master mode The following basic rules apply to entries made in the master mode e Confirm a
34. te The IP address of the target computer can not be entered in the master mode For this purpose a TELNET connection must be established by an external computer Additional FTP CLIENT settings The Ethernet 690 interface controls a large number of parameters only the most important of which are to be set in the master mode of the IND690 Sys Most other parameters can only be set when a browser connection is to be established from a computer on the network to the IND690 Sys Operating instructions 22012856 05 06 31 Settings in the master mode IND690 Sys Establish the browser connection l Start a browser on a computer in the same network segment for example Microsoft Internet Explorer Enter the IP address of the Ethernet 690 interface The following login prompt is displayed E Wetec sw Com Server If appropriate enter the password The Com server can now be configured Configuration of the Com server 1 32 Set the Com server to the factory setting To do so click the following command buttons Login gt OK gt Logout gt Restore Default Deactivate the C Addr mode To do so click the following command buttons Login gt OK gt SETUP Port O High Speed Serial gt TCP IP Mode gt TCP Client gt Client C Addr C gt Send gt Back gt Logout gt Save Set the port number of the FTP protocol and the IP address of the computer on which the FTP server progr
35. the network Entry format 000 000 000 000 Example 176 120 98 3 FTP SECURITY Enter the FTP username and the accompanying FTP password for the IND690 Sys Both must be assigned by IT personnel of the administrator who will also enter these data into his FTP server program The IND690 Sys identifies itself to the FTP server under the FTP username FTP FILE Enter the drive directory and name of the file which is to be transferred from the IND690 Sys to the FTP server Valid directory identification conventions examples C OS TEST or C OS TEST A or must always be entered as the last character RECEIVE TIMEOUT This timeout can be extended after a connection until the IND690 Sys aborts and displays a fault message The FTP server program should identify itself during this timeout This timeout is strongly dependent upon the administrator s network load Factory setting 3000 ms TEST Test function which establishes an FTP connection from the IND690 Sys to a computer A simple character string which is to end up in a file in the target computer must be entered The parameters of the FTP SECURITY and FTP FILE menus are used for the connection The IND690 Sys reports whether or not the characters could be transferred successfully At the latest this is done after the receive timeout has been extended In addition the reply from the FTP server program is displayed in 2 receive strings No

Download Pdf Manuals

image

Related Search

Related Contents

ToolMap User Manual    4017307a important  ・ 問価都直プロデュース 節電・省エネー品質管理に効果を発揮  Samsung NX100 manual de utilizador  Trust Vibration Feedback Steering Wheel GM-3400 & Test Drive Unlimited  User manual  Soehnle Flip  HEARLab™ User Manual  BEDIENUNGSANLEITUNG  

Copyright © All rights reserved.
Failed to retrieve file