1. Hewlett Packard HPT 2 also required for cardiac output simulation on HP patient monitoring systems 2199257 HPT 2 temperature adapter Hewlett Packard 2 pin COA 1 also required for cardiac output simulation on HP patient monitoring systems 2199379 COA 2 adapter Gould Spectramed Model 1445 Models for medSim 300B with Option 1 and Cardiac Output Option 2399728 MS300B US120V 1C 2399737 MS300B AUS250V 1C 2399743 MS300B DEN250V 1C 2399755 MS300B SHK250V 1C 2399762 MS300B ISR250V 1C 2399770 MS300B ITAL250V 1C 2399781 MS300B IND250V 1C 2399801 MS300B SWZ250V 1C 2399812 MS300B UK250V 1C Optional Accessories for medSim 300B with Option 1 and Cardiac Output Option 2248554 Multipurpose hard sided watertight carrying case Cardiac Output Bath Injectate Adapters Note Modified Switchcraft 4 pin SL 40 F compatible panel mounted connector included with the 23A Controller For systems requiring a different injectate connector an existing cardiac output cable can be modified using Fluke Biomedical s general purpose connector or additional adapters can be used See following list 2392158 General purpose connector 2199240 COA 1 cardiac output adapter Hewlett Packard HPT 2 also required for cardiac output simulation on HP patient monitoring systems 2199257 HPT 2 temperature adapter Hewlett ackard 2 pin COA 1 also required for cardiac output simulation on HP patient monitoring systems 2199379
2. Hz low pass filter Impedance to the RL Lead Limb leads selectable at 500 1000 1500 and 2000 Q V leads at 1000 Q accuracy 5 ST Segments 18 total normal iso electric elevated and depressed ST Segment Levels Lead II 0 8 mV to 0 8 mV in 0 1 mV steps on lead II including two 0 05 mV steps Includes manual stepping and auto stepping modes at 12 s intervals Operates at ECG rates from 30 BPM to 160 BPM baseline ECG modified during arrhythmias Axis Deviation Normal intermediate horizontal and vertical baseline ECG modified during arrhythmias Neonatal Mode ECG R wave width reduced to 40 ms and dynamic BP selections reduced by 25 ECG Performance Testing Amplitudes set by baseline ECG amplitude Lead lis 0 7 x lead II lead III is 0 3 x lead II V leads are same as lead II Waveforms Lead II and V Leads Square Wave 2 Hz at 1 mV p p Pulse 4s at 1 mV Sine Waves 0 05 0 5 1 10 25 30 40 50 60 and 100 Hz at 1 mV Triangle Wave 2 Hz at 1 mV R Wave Detector Test 60 BPM Haver triangle wave with selectable amplitude and width that can be automatically or manually operated Width 20 ms increments from 20 ms to 200 ms and two smaller widths of 8 ms and 12 ms auto step time interval is 6 s Amplitude Lead II and V 0 05 mV to 0 5 mV in 0 05 mV steps 0 5 mV to 5 5 mV in 0 25 mV steps auto step time interval is 6 s Environmental Requirements Operating Temperature 59 F to 95 F 15 C
3. on T early and standard PVC Per Minute O to 25 manual and auto stepping modes auto step time interval is 60 s PVC Total Counts number of PVCs generated maximum count is 65535 Defibrillator Emergency 1 ECG starts normally and changes to ventricular fibrillation after 2 PVCs R on T defibrillation converts back to normal Emergency 2 ECG starts normally changes to ventricular tachycardia then to ventricular fibrillation defibrillation converts back to normal Elective Cardioversion ECG shows atrial fibrillation properly timed defibrillation pulse converts back to normal late defibrillation pulse causes ventricular fibrillation cardioversion time window is 100 ms from the R wave peak Sync A Pace Input Level Triggered by positive voltage transition through 0 4 V maximum voltage is 35 V and input impedance is 15 kQ Respiration Output Configuration Lead I or II RL LL Baseline Impedance 500 1000 1500 and 2000 Q Accuracy 5 Delta Impedance O 0 1 0 2 0 5 1 and 3 Q Accuracy 10 Normal Physiological Rate 15 20 30 40 60 and 120 BPM Accuracy 5 Apnea Off momentary continuous 12 s and 32 s Ratio 5 1 4 1 3 1 2 1 and 1 1 inspiration expiration Baseline Shift Delta impedance reduced to 1 6 and shifted to positive or negative rate shifted to 120 BPM for 12 s each min Ventilator Simulation 40 BPM at fixed ratio other parameters variable as in normal Blood Pressure Input Out
4. COA 2 adapter Gould Spectramed Model 1445 ordering information continued on next page About Fluke Biomedical Fluke Biomedical is the world s leading manufacturer of quality biomedical test and simulation products In addition Fluke Biomedical provides the latest medical imaging and oncology quality assurance solutions for regulatory compliance Today biomedical personnel must meet the increasing regulatory pressures higher quality standards and rapid technological growth while performing their work faster and more efficiently than ever Fluke Biomedical provides a diverse range of software and hardware tools to meet today s challenges Fluke Biomedical Regulatory Commitment As a medical device manufacturer we recognize and follow certain quality standards and certifications when developing our products We are ISO 9001 certified and our products are e FDA Compliant e CE Certified where required e NIST Traceable and Calibrated e UL CSA ETL Certified where required Me jomedical Fluke Biomedical Better products More choices One company Fluke Biomedical PO Box 9090 Everett WA 98206 9090 USA Fluke Biomedical Europe AS Vegamot 8 N 7048 Trondheim Norway For more information contact us In the U S A 800 648 7952 or Fax 425 446 5629 In Europe M East Africa 47 73954700 or Fax 47 73954701 From other countries 1 425 347 6100 or Fax 1 425 446 5629 Email sales flukebiomedica
5. FLUKE MM riomedical medSim 300B Patient Simulator Technical Data The full featured medSim 300B is the most versatile patient simulator on the market today It is designed to meet the most complex inspection requirements and offers comprehensive simulation with a wide range of features for trend testing The base model includes 12 lead ECG 4 blood pressure channels and respiration and temperature simulation Preset waveform sequences along with 15 programmable sequences simulate a broad range of physiological events Two expansion options are available to give the device even greater versatility Expansion Option 1 features cardiac catheterization intra aortic balloon assist pump IABP and direct fetal maternal ECG intrauterine pressure IUP simulation The cardiac output simulation option features fixed waveforms 3 trending sequences and normal and defective curves to verify performance of cardiac output computers The medSim 300B is portable and an optional handheld controller makes testing easy and convenient For automated testing and documentation capability the medsim 300B is compatible with medTester 5000C Fluke Biomedical s automation hub for biomedical equipment testing Key Features e 12 lead ECG simulation e Four invasive blood pressure channels including Swan Ganz simulation e Respiration and temperature selections Interactive defibrillator training capability e Preset waveform sequence
6. G intrauterine pressure IUP simulation 2399546 2399554 2399568 2399579 2399587 2399593 2399606 2399614 2399623 MS300B US 120V 01 MS300B AUS250V 01 MS300B DEN250V 01 MS300B SHK250V 01 MS300B ISR250V 01 MS300B ITAL250V 01 MS300B IND250V 01 MS300B SWZ250V 01 MS300B UK250V 01 Optional Accessories for medSim 300B with Option 1 2248554 Multipurpose hard sided watertight carrying case Intra Aortic Balloon Assist Pump Sync Cables 2199747 2199786 DS A Datascope System 9 DS 1 BP cable required KT A Kontron K200 KAAT KT 1 BP cable required Models for medSim 300B with Cardiac Output Option 2399638 MS300B US 120V CO 2399645 MS300B AUS250V CO 2399650 MS300B DEN250V CO 2399661 MS300B SHK250V CO 2399677 MS300B ISR250V CO 2399689 MS300B ITAL250V CO 2399692 MS300B IND250V CO 2399704 MS300B SWZ250V CO 2399719 MS300B UK250V CO Optional Accessories for medSim 300B with Cardiac Output Option 2248554 Multipurpose hard sided watertight carrying case Cardiac Output Bath Injectate Adapters Note Modified Switchcraft 4 pin SL 40 F compatible panel mounted connector included with the 23A Controller For systems requiring a different injectate connector an existing cardiac output cable can be modified using Fluke Biomedical s general purpose connector or additional adapters can be used See following list 2392158 General purpose connector 2199240 COA 1 cardiac output adapter
7. M Protocol System Propaq series TK 1 6M Puritan Bennett PB 240 DX 1 10F Quinton Q Cath series QM 1 6M Siemens SIRECUST series SM 1 and Siemens Medical Transducer Adapter 3368 383 E530U used to run a single invasive BP channel on the Siemens Medical SC6000 and SC9000 series monitors SM 1 10M Siemens Micor Mingo SM 3 15M SpaceLabs ALPHA9 703R SL 1 5M SpaceLabs 1050 1700 PCMS series SpaceLabs adapters 700 0028 00 and 0120 0551 00 with TK 1 used when testing the new UltraView Command Module TK 1 6M Universal unterminated UU 1 5 Pin DIN one end only Witt Biomedical EM 1 6F Temperature Cables 2392199 2199004 2199019 2199291 2199257 CI 3 cable assembly UT 1 standard 1 4 in phone plug compatible with YSI 400 series 2 conductor used to test SpaceLabs UltraView Command Module with adapters 700 0031 00 available from SpaceLabs UT 2 standard 1 4 in phone plug compatible with YSI 700 series 3 conductor UT 3 unterminated cable DIN plug on one end only HPT 2 temperature adapter Hewlett Packard 2 pin used with UT 1 for HP monitors Interface Cables 2199070 2199225 PC remote control interface cable right angle DIN to female DB25 Patient simulator to medTester interface cable right angle DIN to female DB25 Models for medSim 300B with Option 1 cardiac catheterization intra aortic balloon assist pump IABP simulation direct fetal maternal EC
8. X 1 10F Fakuda Denshi DS3300 series FD 2 12M GE Marquette Medical Corametrics 115 116 142 145 556 CM 3 Nicolet round 12M GE Marquette Medical PPG E for M DR EM 1 6F GE Marquette Medical 7000 and TRAM AR series only MQ 2 8M round GE Marquette Medical Dash Eagle Solar Tram and MacLab MQ 3 rectangular 11M Hewlett Packard Philips 78 300 78 500 78 800 Merlin Viridia Omnicare HP Philips M1006B iBP module has a sensitivity of 5 uV V mmHg only The HP 3 cable should be selected for this application HP 3 12M 5 pV Hewlett Packard Philips 78 300 78 500 78 800 Merlin Viridia Omnicare HP 4 12M 40 pV Hewlett Packard Philips 8040A M1350A HP 8 intrauterine pressure only 12M 40 pV HP Philips 80404A HP 9 intrauterine pressure only 12M 5 pV Invivo Research TK 1 6M Ivy Biomedical 400 and 700 series TK 1 6M 2199096 Kontron Medical Mini Super Color Mon series KT 1 6M Medical Data Electronics Escort series PC 1 6M 2199387 2199682 2198893 2198978 2199627 2198902 2198916 2199694 2199701 2198879 2198879 2198940 2198933 2199107 2198879 2198940 2198879 2200955 2199176 2198925 2199666 2198957 2198879 2392173 2198893 Mennen Medical Horizon series MM 1 6M Nihon Kohden NK 1 6M North American Drager Vitalert 2000 TK 1 6M Physio Control VSM series PC 1 6
9. ht ventricle 25 0 pulmonary artery 25 10 pulmonary artery wedge 10 2 triangle 30 2 Hz triangle 300 2 Hz Static 10 5 O 20 40 80 100 200 250 and 300 manual or auto stepping at 12 s intervals Temperature Variable 93 2 F 34 C 98 6 F 37 C 104 F 40 C hyperthermia hypothermia and spike accuracy 0 7 F 0 4 C Fixed 98 6 F 37 C channel 2 accuracy 0 2 F 0 1 C Probe Compatibility 400 and 700 series YSI types Isolation Variable temperature electrically isolated from rest of instrument except cardiac output fixed temperature isolated from all other outputs ECG Artifact Wave Type 50 Hz 60 Hz muscle or baseline wander Leads Any wave type can be added to any limb lead or to V leads or to all leads Size 0 25 0 5 and 1 times the lead II ECG amplitude setting Blood Pressure Respiration Artifact Respiration artifact can be injected into any blood pressure waveform Arterial and left ventricle waveforms are modulated by selected respiration rate at 5 to 10 All others have respiration added to them at 5 mmHg or 10 mmHg Sequences Three preprogrammed step sequences four user programmable step sequences Normal Sinus Rhythm Rates 30 60 80 120 160 200 240 and 300 BPM accuracy 1 Amplitudes Lead II 0 05 mV to 0 5 mV in 0 05 mV steps 0 5 mV to 5 5 mV in 0 25 mV steps manual and auto step interval of 6 s Accuracy 5 on lead II into a 100
10. l com Web access http www flukebiomedical com 2006 Fluke Biomedical All rights reserved Specifications subject to change without notice Printed in U S A LITO49
11. put Impedance 300 Q Exciter Input Voltage Range 2 V to 16 V Exciter Input Frequency Range DC to 4 kHz Output Sensitivity 5 nV mmHg or 40 pV V mmHg Output Range 10 mmHg to 300 mmHg on BP1 BP2 and BP4 10 mmHg to 30 mmHg on BP3 Accuracy 1 of full range 1 mmHg at 80 BPM normal sinus rhythm ECG only Rate All dynamic pressures track all normal sinus rhythm rates and track all arrhythmias Isolation Blood pressure circuitry is electrically isolated from all other medSim 300B outputs Channel 1 mmHg Atmosphere 0 arterial 120 80 left ventricle 120 0 central venous pressure 15 10 right ventricle 25 0 pulmonary artery 25 10 pulmonary artery wedge 10 2 Static 10 5 O 20 40 80 100 200 250 and 300 manual or auto stepping at 12 s intervals Channel 2 mmHg Atmosphere 0 arterial 120 80 left ventricle 120 0 central venous pressure 15 10 right ventricle 25 0 pulmonary artery 25 10 pulmonary artery wedge 10 2 Static 10 5 0 20 40 80 100 200 250 and 300 manual or auto stepping at 12 s intervals Channel 3 mmHg Atmosphere 0 central venous pressure 15 10 right ventricle 25 0 pulmonary artery 25 10 pulmonary artery wedge 10 2 Static 10 5 0 5 10 20 and 30 manual or auto stepping at 12 s intervals Swan Ganz Start insert inflate deflate and remove Channel 4 mmHg Atmosphere 0 arterial 120 80 left ventricle 120 0 rig
12. s and 15 programmable sequences that simulate a wide range of physiological events for trend testing e 32 arrhythmia selections e Battery operated e RS232 serial port for computer control Compatible with medTester 5000C for automated testing and documentation Optional Features e Option 1 expansion cardiac catheterization intra aortic balloon assist pump IABP simulation direct fetal maternal ECG intrauterine pressure IUP simulation e Cardiac output simulation 23A Controller Technical Specifications Sync Input accepted during defib training and intra aortic balloon assist pump IABP augmentation option 1 RS232 Interface With the exception of those functions controlled by slide switches most functions may be controlled remotely Non programmable functions include all utilities Optional RS232 cable required for remote control via PC Baud Rate 300 600 1200 and 2400 ECG General Lead Configuration 12 lead ECG with 9 independent outputs for each signal lead referenced to RL Output Impedances 500 1000 1500 and 2000 Q to RL High Level Output 0 2 V per mV of low level selection Amplitude Accuracy 5 2 Hz square wave at 1 mV p p lead II PVC Parameter Selection Premature Beat Insertion Push button insertion of PVC PAC and PNC during 30 BPM to 160 BPM normal sinus mh Types 1 2 3 and 4 ventricular sites Timing R on T early and standard O min to 25 min with manual stepping and autos
13. tepping modes autostep interval 60 s Count Number of PVCs generated 65535 max Pacemaker Rhythms Async 75 BPM demand 1 demand 2 AV sequential non capture non function independent settings for atrial and ventricular pacer pulses Pulse 700 mV to 700 mV 29 levels accuracy 10 of setting 0 2 mV Width 0 1 0 2 0 5 1 0 and 2 ms accuracy 5 Manual and autostepping modes for both amplitude and width autostep time interval of 6 s Pulse Polarity Positive or negative Min Pulse Amplitude 0 1 mA or 15 V Input Impedance 15 kQ Arrhythmia Selections Baseline Rate 80 BPM Supraventricular Atrial fibrillation 1 atrial fibrillation 2 atrial flutter sinus arrhythmia missed beat 80 BPM missed beat 120 BPM paroxysmal atrial tachycardia PAT nodal PNC supraventricular tachycardia Premature Beats Atrial PAC nodal PNC PVC multifocal PVCs Conduction Defects First degree A V block second degree A V block type 1 second degree A V block type 2 third degree A V block right bundle branch block left bundle branch block Ventricular Rhythms Frequent multifocal PVCs 24 min bigeminy trigeminy pair PVCs run of 5 PVCs run of 11 PVCs ventricular tachycardia V Fibrillation fine V Fibrillation coarse dying heart complex EMD asystole Pacemaker See Pacemaker section Premature Ventricular Contraction PVC Parameter Selections PVC Type 1 2 3 and 4 PVC Timing R
14. to 35 C Storage Temperature 32 F to 131 F 0 C to 55 C General Information Display 2 line by 24 character LCD Power Two 9 V batteries battery eliminator Dimensions 7 in Lx 10in Wx3inH 17 8 cm L x 25 4 cm W x 7 6 cm H Weight 3 5 lb 1 6 kg Ordering Information Model Base Models Patient Simulation 2247184 MS300B US120V 2395133 MS300B AUS250V 2395140 MS300B DEN250V 2395157 MS300B SHK250V 2395169 MS300B ISR250V 2395178 MS300B ITAL250V 2395184 MS300B IND250V 2395191 MS300B SWZ250V 2395207 MS300B UK250V Standard Accessories for medSim 300B Base Model 2243039 User service manual 2392826 Soft sided vinyl carrying case 2392729 ECG electrode adapter for lead test Battery Eliminator as ordered 2183983 120 VAC to 9 V battery eliminator 2183990 220 VAC to 9 V battery eliminator Optional Accessories for medSim 300B Base Model 2244952 23A Controller CI 3 cardiac output box overlay kit included model 2217384 2248554 Multipurpose hard sided watertight carrying case Blood Pressure Cables 2198969 Advanced Medical Systems FM 660 FM 670 IT 1 intrauterine pressure 10M Airshields Fetascan 1400 LT 1 intrauterine pressure 10M 2198969 2198879 BCI International TK 1 6M 2198879 Criticare Systems Inc 1100 TK 1 6M 2198879 Critikon Dinamap Plus TK 1 6M 2198887 Datascope DS 1 6F 2200955 Datex AS 3 CS 3 Compact Cardio Cap II Critical Care Light D
Download Pdf Manuals
Related Search
Related Contents
Prime-Line R 7153 Instructions / Assembly User Manual - Spectrum Controls, Inc. 旧法の規定に基づき製造又は輸入していた医療用具の新法に係る取扱い SiriusXM XADH2 VDRO User`s Manual - Accurate Technology, Inc. 9191 Monitor Manuel d`installation (pdf format 887.93kb) Instrucciones de uso, Monitor Spot Vital Signs LXi de Welch Allyn Samsung SGH-G800 Brugervejledning Copyright © All rights reserved.