Home
118-5 Sump Pump Hide-Away Basin System
Contents
1. gt DE NTAI E PUMP SYSTEM INSTALLATION AND SERVICE MANUAL 118 5 Sump Pump HYDROMATIC oaa aa 14 5 W 16 H 1 5 DISCHARGE OPENING NOTE TO THE INSTALLER Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system 293 WRIGHT STREET DELAVAN WI 53115 WWW HYDROMATIC COM PH 888 957 8677 269 TRILLIUM DRIVE KITCHENER ONTARIO CANADA N2G 4W5 PH 519 896 2163 2013 Pentair Ltd All Rights Reserved W 03 423 Rev 03 04 13 General Information Thank you for purchasing your Hydromatic product To help ensure years of trouble free operation please read the following manual carefully Before operation Read the following instructions carefully Reasonable care and safe methods should be practiced Check local codes and requirements before installation Attention This manual contains important information for the safe use of this product Read this manual complete ly before using this product and refer to it often for continued safe product use DO NOT THROW AWAY OR LOSE THIS MANUAL Keep it in a safe place so that you may refer to it often Warning Before handling these pumps and controls always disconnect the power first Do not smoke or use sparkable electrical devices or flames in a septic gaseous or possible septic sump California Proposition 65 Warning AWARNING This product and related accessories conta
2. piping may be plumbed Vent Provision has been made for a 2 vent to allow maximum volume for any application and proper operation of pump The vent may be reduced to no less than 1 1 4 Venting is essential for proper pump operation and should not be omitted The 118 5 Hide Away Basin System may be vented into an existing vent stack or use a BOCA in line vent Check local codes Discharge Do not restrict discharge line below 1 1 4 A check valve MUST be installed to prevent backflow of water after each cycle If you are using 1 1 2 or 1 1 4 PVC pipe on the discharge line a Hydromatic CV 170 check valve is recommend ed Once check valve has been installed plumb the discharge line into an existing drain line Basin Hydromatic s 118 5 Hide Away Basin System includes a corro sion resistant polypropylene tank with a gasket cover An inlet strainer is provided in the basin cover above the inlet The strainer is sealed and held in place with the four screws provided System e Maintenance Caution Always disconnect pump from the electrical power source before doing any maintenance Your sink pump system is manufactured for easy maintenance Each unit is individually factory tested to ensure proper adjustment and operation If unit fails to operate properly carefully read instructions again to make sure correct procedure has been followed Electrical Information Note The basin
3. LIPS 054344061 COVER SINK TANK STRAINER 256864000 GASKET STRAINER 256888000 STRAINER 256854000 FASTENERS 1 4 20 X 5 8 18475A007 PIPE 1 1 2 X 12 TOE 13665 018 3 GROMMET ELECTRICAL 256894000 NAMEPLATE 14849 000 1 LABEL WARNING 14848 000 1 CARTON 14851 000 1 2 3 4 5 6 7 8 9 Limited Warranty HYDROMATIC warrants to the original consumer purchaser Purchaser or You of HYDROMATIC Sump Pumps Effluent Pumps Sewage Pumps other than 2 1 2 and Package Systems that they will be free from defects in material and workmanship for the Warranty Period of 36 months from date of manufacture Our warranty will not apply to any product that in our sole judgement has been subject to negligence misapplication improper installation or improper maintenance Without limiting the foregoing operating a three phase motor with single phase power through a phase converter will void the warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick trip overload relays of the recommended size or the warranty is void Your only remedy and HYDROMATIC s only duty is that HYDROMATIC repair or replace defective products at HYDROMATIC s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received aft
4. er the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture whichever comes first HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty so the above limitations or exclusions may not apply to You This warranty gives You specific legal rights and You may also have other rights which vary from state to state This Limited Warranty is effective June 1 2011 and replaces all undated warranties and warranties dated before June 1 2011 HYDROMATIC 293 Wright Street Delavan WI 53115 Phone 888 957 8677 Fax 800 426 9446 Web Site hydromatic com
5. in chemicals known to the State of California to cause cancer birth defects or other reproductive harm Pump Warning Warranty void if product is modified drilled painted or altered in any way if used to pump hot water or to pump liquids other than water such as but not limited to chemicals fertilizers flammable liquids herbicides mud tar cement wood chips or otherwise abused 2 The model 118 5 Hide Away Basin System is specially designed for pumping wastewater from laundry trays washing machines wet bars water softeners dehumidifiers etc This pump system installs above floor level no need to dig a sump This pump system cannot be used for laundry dishwasher applications in a commercial or industrial environment Installation Instructions Diagram 1 shows the various connections that must be made for proper installation and opera tion This is only a guide actual installation may vary depending on the particular situation Inlet A 1 1 2 inlet is provided on the 118 5 Hide Away Basin System One method of hookup is to use a 1 1 2 PVC MIP adapter or a 1 1 2 PVC MIP marvel connection or a similar type of connection You may use a 1 1 2 extension tailpiece or 1 1 2 PVC pipe it depends on the type of fittings used on the basin inlet The P Trap should be installed once the appropriate connections are made on the basin inlet Once these fittings are installed the rest of the
6. strainer requires routine maintenance The strainer should be removed and cleaned monthly to prevent clogging WARNING Risk of electrical shock This pump is supplied with a grounding conductor and grounding type attachment plug To reduce risk of electrical shock connect only to a properly grounded grounding type receptacle This pump has not been investigated for use in swimming pool areas DO NOT WORK ON PUMP UNTIL POWER IS 1 1 8 5 UNPLUGGED Parts List DO NOT cut off ground pin or use an adapter fitting DO NOT use an extension cord The pump power AA o cord should be connected to a Vent Pipe separately fused grounded 115 volt eer line with a minimum capacity of 15 amps NEVER touch the pump when it is connected to electrical power i Discharge Pipe and Check Valve not supplied Gas tight Cover The receptacle should be located at least 4 feet above floor level When wiring this pump follow all local electrical and safety codes and ordinances as well as the most recent National Electrical Code N E C ANSI NFPA 70 2000 Inlet Pipe and Trap not supplied Laundry Tray Wet Bar 5 f Dehumidifier Diagram 1 Pump Switch and Internal Piping Water Softener Washing Machine etc not supplied Description Part No Qty BASIN SINK TANK 25530 000 BV Al SUMP PUMP 52623 000 1 COVER SINK BASIN 255400001 GASKET COVER 23150074000 SCREW 10 32 X 3 4 PANHEAD PHIL
Download Pdf Manuals
Related Search
Related Contents
cahier des charges techniques - Ministère de l`écologie, du FUTURA 26 IN FUTURA 35 IN MANUAL DE USUARIO Safety Recall AirLive HP-3000E OCZ Technology OCZSSDPX-1HSDL4P User Manual - Primo Water Store Manual de instrucciones Space Shuttle Program Payload Bay Payload User`s Guide "service manual" Copyright © All rights reserved.