Home
        118-5 Sump Pump Hide-Away Basin System
         Contents
1.  gt  DE NTAI E PUMP SYSTEM INSTALLATION AND    SERVICE MANUAL  118 5 Sump Pump    HYDROMATIC    oaa aa     14 5  W  16  H  1 5  DISCHARGE OPENING        NOTE  TO THE INSTALLER  Please make sure  you provide this manual to the owner of the  pumping equipment or to the responsible party  who maintains the system     293 WRIGHT STREET  DELAVAN  WI 53115 WWW HYDROMATIC COM  PH  888 957 8677    269 TRILLIUM DRIVE  KITCHENER  ONTARIO  CANADA N2G 4W5  PH  519 896 2163       2013 Pentair  Ltd  All Rights Reserved  W 03 423  Rev  03 04 13     General    Information       Thank you for purchasing your  Hydromatic   product  To help ensure  years of trouble free operation  please  read the following manual carefully     Before operation    Read the following instructions  carefully  Reasonable care and safe  methods should be practiced  Check  local codes and requirements before  installation     Attention    This manual contains important  information for the safe use of this  product  Read this manual complete   ly before using this product and refer  to it often for continued safe product  use  DO NOT THROW AWAY OR  LOSE THIS MANUAL  Keep it in  a safe place so that you may refer to  it often     Warning   Before handling these pumps and  controls  always disconnect the    power first  Do not smoke or use  sparkable electrical devices or flames  in a septic  gaseous  or possible  septic sump    California Proposition 65  Warning   AWARNING  This product and  related accessories conta
2.  piping may be  plumbed     Vent    Provision has been made for a 2   vent to allow maximum volume for  any application and proper operation  of pump  The vent may be reduced  to no less than 1 1 4   Venting is  essential for proper pump operation  and should not be omitted  The 118 5  Hide Away Basin System may be  vented into an existing vent stack  or use a BOCA in line vent  Check  local codes     Discharge    Do not restrict discharge line below  1 1 4   A check valve MUST be  installed to prevent backflow of  water after each cycle  If you are                   using 1 1 2  or 1 1 4  PVC pipe  on the discharge line  a Hydromatic  CV 170 check valve is recommend   ed  Once check valve has been  installed  plumb the discharge line  into an existing drain line     Basin   Hydromatic   s 118 5 Hide Away  Basin System includes a corro   sion resistant polypropylene tank  with a gasket cover  An inlet strainer  is provided in the basin cover above  the inlet  The strainer is sealed and  held in place with the four screws  provided     System    e  Maintenance  Caution    Always disconnect pump from    the electrical power source before  doing any maintenance  Your sink  pump system is manufactured for  easy maintenance  Each unit is  individually factory tested to ensure  proper adjustment and operation   If unit fails to operate properly   carefully read instructions again to  make sure correct procedure has been  followed     Electrical    Information       Note  The basin 
3. LIPS 054344061  COVER  SINK TANK STRAINER 256864000  GASKET  STRAINER 256888000  STRAINER 256854000  FASTENERS  1 4 20 X 5 8  18475A007  PIPE  1 1 2 X 12  TOE 13665 018 3  GROMMET  ELECTRICAL 256894000  NAMEPLATE 14849 000 1  LABEL  WARNING 14848 000 1  CARTON 14851 000 1       2  3  4  5  6  7  8  9                      Limited Warranty   HYDROMATIC warrants to the original consumer purchaser     Purchaser    or    You     of HYDROMATIC Sump Pumps  Effluent  Pumps  Sewage Pumps  other than 2 1 2      and Package Systems  that they will be free from defects in material and  workmanship for the Warranty Period of 36 months from date of manufacture    Our warranty will not apply to any product that  in our sole judgement  has been subject to negligence  misapplication  improper  installation  or improper maintenance  Without limiting the foregoing  operating a three phase motor with single phase power  through a phase converter will void the warranty  Note also that three phase motors must be protected by three leg  ambient  compensated  extra quick trip overload relays of the recommended size or the warranty is void    Your only remedy  and HYDROMATIC   s only duty  is that HYDROMATIC repair or replace defective products  at  HYDROMATIC   s choice   You must pay all labor and shipping charges associated with this warranty and must request warranty  service through the installing dealer as soon as a problem is discovered  No request for service will be accepted if received  aft
4. er the Warranty Period has expired  This warranty is not transferable    EXCEPTIONS  Hydromatic Special Application Pumps  Battery Back Up Sump Pumps  Filtered Effluent Pumps  Grinder  Pumps  and 2 1 2    Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of  manufacture  whichever comes first    HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL  INCIDENTAL  OR CONTINGENT   DAMAGES WHATSOEVER    THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED  WARRANTIES  INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR  A PARTICULAR PURPOSE  THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION  PROVIDED HEREIN    Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an  implied warranty  so the above limitations or exclusions may not apply to You  This warranty gives You specific legal rights and  You may also have other rights which vary from state to state    This Limited Warranty is effective June 1  2011 and replaces all undated warranties and warranties dated before June 1  2011     HYDROMATIC  293 Wright Street  Delavan  WI 53115  Phone  888 957 8677    Fax  800 426 9446    Web Site  hydromatic com          
5. in chemicals  known to the State of California to  cause cancer  birth defects or other  reproductive harm        Pump  Warning    Warranty void if product is  modified  drilled  painted  or  altered in any way  if used to pump  hot water  or to pump liquids other  than water  such as but not limited  to chemicals  fertilizers  flammable  liquids  herbicides  mud  tar  cement   wood chips   or otherwise abused     2                 The model 118 5 Hide Away Basin  System is specially designed for  pumping wastewater from laundry  trays  washing machines  wet bars   water softeners  dehumidifiers  etc   This pump system installs above  floor level  no need to dig a sump   This pump system cannot be used for  laundry dishwasher applications in a  commercial or industrial environment     Installation  Instructions    Diagram 1 shows the various  connections that must be made  for proper installation and opera   tion  This is only a guide  actual  installation may vary depending on  the particular situation     Inlet    A 1 1 2  inlet is provided on the  118 5 Hide Away Basin System  One  method of hookup is to use a 1 1 2   PVC MIP adapter or a 1 1 2  PVC  MIP marvel connection  or a similar  type of connection   You may use a  1 1 2  extension tailpiece or 1 1 2   PVC pipe  it depends on the type of  fittings used on the basin inlet  The  P Trap should be installed once the  appropriate connections are made on  the basin inlet  Once these fittings are  installed the rest of the
6. strainer requires  routine maintenance  The strainer  should be removed and cleaned  monthly to prevent clogging     WARNING  Risk of electrical  shock  This pump is supplied with a  grounding conductor and grounding  type attachment plug  To reduce risk  of electrical shock  connect only to  a properly grounded grounding type  receptacle  This pump has not been  investigated for use in swimming  pool areas     DO NOT WORK ON  PUMP UNTIL POWER IS 1 1 8 5    UNPLUGGED  Parts List    DO NOT cut off ground pin or use  an adapter fitting  DO NOT use an  extension cord  The pump power AA o   cord should be connected to a     Vent Pipe  separately fused  grounded 115 volt eer  line with a minimum capacity of 15  amps  NEVER touch the pump when  it is connected to electrical power  i       Discharge Pipe  and Check Valve   not supplied            Gas tight  Cover    The receptacle should be located  at least 4 feet above floor level   When wiring this pump follow all  local electrical and safety codes and  ordinances as well as the most recent  National Electrical Code    N E C   ANSI NFPA 70   2000              Inlet Pipe  and Trap   not supplied           Laundry Tray    Wet Bar 5 f  Dehumidifier Diagram 1 Pump  Switch and  Internal Piping         Water Softener  Washing Machine  etc   not supplied        Description Part No  Qty        BASIN  SINK TANK 25530 000  BV Al  SUMP PUMP 52623 000 1  COVER  SINK BASIN 255400001  GASKET  COVER 23150074000  SCREW  10 32 X 3 4  PANHEAD PHIL
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Le Monde d`Isvadar  (Microsoft PowerPoint - CLSM Avril 2013.ppt [Mode de    BCS-100    Tecumseh RKA5480YXG Performance Data Sheet  全方向デジタルカメラLadybug3 対応録画ソフト  FOR HIRE  Sony 17" Silver Flat Panel LCD  User`s Manual DPharp PROFIBUS PA Communication Type (EJX    Copyright © All rights reserved. 
   Failed to retrieve file