1.          SMARTFREEZE    Temperature and Humidity  High Performance Controller  for Uprights and Refrigerated   Tables    Manual   User Service Installation     S MARTEREECE    INDEX       USER MANUAL      1  SAFETY    2  TECHNICAL SPECIFICATIONS    3  CONNECTIONS    4  KEYBOARD DESCRIPTION    5  KEYS DESCRIPTION    6  HACCP FUNCTIONS    7  USER MENU DESCRIPTION       SERVICE MANUAL      8  MENU SERVICE    9  CONTROLLER ACTIONS    10  D TEST    11  ELECTRICAL LOADS CONTROL    12  FUNCTION FAILURES VS  WORKING MODES    13  SUPER PARAMETERS    14  PARAMETERS       INSTALLATION MANUAL      15  INSTALLATION      SMARTFREEZE          USER MANUAL    1  SICUREZZA    2  TECHNICAL SPECIFICATIONS             1     Hold the present booklet in a sit where the  consultation it is easily for the user     Do not power on the controller after or during  installation         mechanical      electrical  intervention since there are some connectors  under high voltage inside     In the controller case there aren t components that  can be managed by the user     VOPOS controllers don t have any protection of  connected loads  Therefore all the loads should be  protected for short circuits  for high low currents   and for right temperatures by appropriate devices  as fuses  magneto thermal switches  etc       Violation of safety rules during the installation and  failure to comply with the instructions contained in  this manual may affect the overall safety level of  controllers     VOPOS Controll
2.      If there is a Low Temperature pre alarm   temperature lt SPU ALL  For parameters details  see  paragraph 14   the controller displays the message LOW  TEMPERATURE  without the event is recorded     6 2 Temperature alarm   If there is an High Temperature alarm   temperature  SPU ALH for longer than ALD min  For  parameters details  see paragraph 14   the controller  displays the message HIGH TEMPERATURE  with the  buzzer that will sound until the temperature returns within  the set limits    If there is a Low Temperature alarm   temperature lt SPU ALL for a time longer than ALD min   For parameters details  see paragraph 14   the controller  displays the message LOW TEMPERATURE  with the  buzzer that will sound until the temperature returns within  the set limits     6 3 Alarm end   If it has been scheduled VSP super parameter  for super  parameters details  see paragraph 13   when alarm ends   the controller displays the message PUSH INFO KEY  alternated by the cold room temperature until INFO is read   This message informs the user that some alarms have  been occurred  if he did not red the message or he did not  hear the buzzer     6 4 Buzzer turning off   The buzzer will be stopped by pressing any key    For temperature alarms  the buzzer turning off inhibits even  the message PUSH INFO KEY  The buzzer can be  enabled and disabled by the schedule of VSP super  parameter  for super parameters details  see paragraph  13     6 4 1 Buzzer reiteration and persistence    Pa
3.     Low pressure        i LOW GAS detected inside gas   i No action      circuit            High consumption   controls dg au i When consumption is too high the relevant load is      LOAD  RLx       a higher than normal  i      onarelay Ux    5   excluded              consumption value          57 SMARTFREEZE          15    13  SUPER PARAMETERS       The controller is associated with a parameters and super parameters setting utility  available in the DOWNLOAD section of  Smartfreeze SERVICE area  http   service smartfreeze com           Weight Operation with zero weight Operation with x weight      add  CSC oe   in ta    SMARTFREEZE                   Weight Operation with zero weight       16 Automatic Energy Saving disabled     7    32 Night amp Daydisabled    MM       64 free     128 Independent humidity control     TS    Weight Operation with zero weight       Fan evaporator disabled        HB       16 Fan condenser off during defrost      32 Fan condenser controlled during defrost           64 Control Rh  on fan times disabled   7     128   free      Current control disabled     TTTS    Relays for temperature failures and alarms       Fan evaporator in parallel to compressor        Fan evaporator off during defrost     7      Fan evaporator not controller during defrost     16    Operation with x weight     ekea   s          Operation with x weight    prin  p c                   Weight Operation with zero weight    1 Manual defrost disabled      2 Compressor off in defros
4.   it however starts   During the waiting period  the controller displays the  message WAITING DEFROST     9 2 2 2 N2   Defrost by serial command   Defrost can be started by a serial command of REALOAD  software or by SFU  Smartfreeze Unit for Remote  Monitoring and Control   if is connected to Vopos    Defrost starts at once or at the end of compressor cycle  with DOP weight 64  for super parameters details  see  paragraph 13  and if S2 temperature is lower that DTEC   for super parameters details  see paragraph 13     9 2 2 3 M3   Automatic defrost at every IDT hours   Defrost can be started at time intervals set by ITD  parameter in hour  for parameters details  see paragraph  14   enabled by DOP weight 3  for super parameters  details  see paragraph 13     Defrost starts at once or at the end of compressor cycle  with DOP weight 64  for super parameters details  see  paragraph 13  and if S2 temperature is lower that DTEC   for super parameters details  see paragraph 13      9 2 2 4 M5   Automatic defrost at RTC time             SMARTFREEZE             Defrost can be started at a determinate time setting DOP  parameter weight 16  for super parameters details  see  paragraph 13     Defrosts day time may be up to 4 hours beginning at SD1    SD2  SD3  SD4  Defrost starts at once or at the end of   compressor cycle with DOP weight 64  for super   parameters details  see paragraph 13  and if S2  temperature is lower that DTEC  for super parameters   details  see paragraph 13    
5.  9 2 2 5 From M6 to M12   Automatic defrosts  started   independently by the controller   These defrosts start independently by controller with   reference to an algorithmic that estimates the ice formation   on the evaporator by the end defrost S2 probe    The defrosts are enabled according to PDO super   parameters weight 128  for super parameters details  see   paragraph 13     Sensitivity to ice presence is determined by SDT parameter    for super parameters details  see paragraph 13   Reducing   SDT value  controller sensitivity to detect the frost presence   on the evaporator increases    In this category there are also defrosts started by controller   when there are specific procedures  such as the D Test    9 2 3 Evaporator fans action during defrost   e forced on   FOP weight 2  it is the typical case of  defrost by compressor off    e forced off   FOP weight  lt  gt 2  for all other types of  defrost    e controlled by FSD   FOP weight   64  for all other  types of defrost  except defrost by compressor off  that  during defrost requires a temporary ventilation to dispose  of the product cold  limiting the increase of temperature  in the cold room  In this case  during defrost  the  evaporator fans follow this rule    v Fan ev  OFF  S2 gt   SET FSD  v              ON  S2   SET FSD 5C   9 2 4 Condenser fans action during defrost   e forced on   FOP weight 32    e forced off   FOP weight  lt  gt 32    e controlled by FCD   FOP weight   64   In this case   during defros
6.  FAS  off for S2 gt    FAS HYF     If S2 is not installed or faulty  fans are on or off in  thermoregulation with reference to the compressor and to  its turning on FAD parameter expired  where FAD  for  parameters details  see paragraph 14  is the consensus  temperature at the turning on and after defrost     9 3 2 Independent fans   With this configuration  evaporator fans will have  consensus only with reference to this condition        on for S2    FAS  off for S2 gt    FAS HYF     If S2 is not installed or faulty  on FAD parameter expired ay  controller turning on  where FAS  for parameters details   see paragraph 14  is the consensus temperature at the  turning on and after defrost    During defrost are following the conditions defined by FOP  super parameter  for super parameters details  see  paragraph 13            9 4 Condensers fan operation    Related parameters    FOP  0  255 1  flag   configuration super parameter   FCE  0  60 1       fan action consensus   HYC  0  20 0 1       condensers fan hysteresis   Condenser fans action transfer   Condenser fans action is transferred to any of the relays by   setting value 04 on relay parameter RLx  for parameters   details  see paragraph 14     9 4 1 Thermoregulation fans   Condenser fans are thermo regulated during cooling with   reference to the following conditions      off  S3 lt  FCE  on  S3 gt  FCE HYC C  for parameters  details  see paragraph 14  with turning off in compressor  pause when temperature FCE    is rea
7.  IS POSSIBLE  buzzer turning off        relay set with value 13 remains normally opened and  closes when there is an alarm  and IT IS NOT  POSSIBLE buzzer turning off        relay set with value 14 remains normally off and  closes when there is an alarm  and IT IS POSSIBLE  buzzer turning off     9 16 Warm action    Related parameters   SET   40 0  40 0 0 1       set point entered from user  menu   HYC  0 0  10 0 0 1       regulation lower hysteresis warm  action   Warm action transfer   Warm action is transferred to any of the relays by setting  value 06 on relay parameter RLx  for parameters details   see paragraph 14     The regulation is done with higher and lower bandwidth  with reference to the set point and HYC differential  for  parameters details  see paragraph 14     The consensus is when the value measured by the S1  probe reaches the  SET HYC   C   the block occurs when  the value measured by the S1 probe reaches the  SET    C   for parameters details  see paragraph 14     If in the controller installation are provided both actions   HYL parameter will be ignored  for parameters details  see  paragraph 14      10 0 D TEST          Related parameters  SET   40 0  40 0 0 1        regulation set point    STB  1 10  num   quantity of stability cycles in phase 0  CYC  1 10  num   quantity of stand by cycles in phase 1  ETT   40 0  40 0 0 1       climbing set point   HYH  0 0  9 9 0 1    upper regulation hysteresis   HYL  0 0  9 9 0 1    lower regulation hysteresis   DT
8.  Mini USB to upgrade firmware  to setting parameters   in out   to download temperature recording data  to  upload refrigerator bill  materials  and to record start  up data         SMARTFREEZE     E          3  CONNECTIONS       VOPOS CE  CONTROLLER e CVC44   m  BUZZER INSIDE Made in Italy    pues Rs485           S1 Thermostat ntc probe i   RS485    S2 Evaporator ntc probe       GND g 4    S3 Monitor Condenser ntc probe     S4  Humidity Sensor 12V  4 20mA      5V      S4 Digital Door Switch   ME  S4   2  Outputs      S4  12V 1    RL1        rele res 1 5HP     230V       RL2a 8A rele n o  resistive g  RL2b 8A rele        resistive              rele resistive  RL4      rele resistive  L Common Line  SUPPLY    110 240 VAC  50 60Hz 3VA       SMARTFREEZE                4  KEYBOARD DESCRIPTION       The keyboard is a touch pad with 4 keys           MENU   ESC KEY  OK KEY adl    UP   LIGHT KEY          DOWN   INFO KEY          5  KEYS DESCRIPTION          e MENU ESC KEY  by this key  from the operation  mode  the controller accesses Menu  from other levels  or when the controller displays a message or an  information string  it has the function of ESC    e OK KEY  it confirms the required action  During the  controller operation mode  without pressing MENU  key  it allows to display the current date and time    e UP LIGHT KEY  in normal display mode  it enables  the UP function  after the selection of MENU for  scrolling menu and submenu items  It increases the  SET POINT and or pa
9.  adjustment lower hystere sis point  ASS    0  255 1  sec   compressor start delay   ADL    0  255 1  sec cycling prevention  minimum time  between two compressor starts     DAC    0  10 1  sec   delay time for compressor turns off     Cooling transfer   Cooling is transferred to any of the relays by setting value  01 on relay parameter RLx  for parameters details  see  paragraph 14     9 1 2 Logic   Cooling is done with higher and lower bandwidth with  reference to the set point and the HYH and HYL  differentials  for parameters details  see paragraph 14    Compressor stops when the value measured by probe S1  reaches  SET HYL C value  after time DAC  for  parameters details  see paragraph 14     Compressor restarts when the value measured by probe  S1 reaches  SET HYH C value    The ADL anticycling parameter  for parameters details  see  paragraph 14  prevents compressor short cycles during  thermoregulation cycles    ASS parameter represents the compressor delay at  controller power on by the keyboard or after the restoration  of power supply  for parameters details  see paragraph 14    Warning    Setting HYH 0  the controller stops temperature alarms  regulation and recording     9 2 Defrost    Related parameters   DOP  0  255 1    num defrost limits exceeded   FOP  0  255 1    num fan parameters exceeded   DTE  0  20 1       temperature at defrost end referred to  S2   DTO  0  60 1    min defrost maximum time   DRP  0 255 1 sec   drip time   ITD  2 24 1  hours   interval
10.  between defrost   SD1  0 24 1  min   time start 1st programmed defrost   SD2  0 24 1  min   time start 2nd programmed defrost   503  0 24 1  min   time start 3rd programmed defrost   SD4  0 24 1  min   time start 4th programmed defrost  Defrost transfer   Defrost is transferred to any of the relays by setting value  02 on relay parameter RLx  for parameters details  see  paragraph 14     9 2 1 Defrost types   The controller handles several types of defrost   programmable by DOP super parameter  for super  parameters details  see paragraph 13           Defrost by compressor off       Electric defrost     Hot gas and inverted cycle defrost     9 2 1 1 Defrost by compressor off   Defrost by compressor off stops the compressor by the  action of the evaporator fans up to the conditions of defrost  end  52 gt  DTE or        expired   for parameters details  see  paragraph 14            9 2 1 2 Electric defrost  Electric defrost turns off the compressor by the operation of  defrost heater up to the conditions of defrost end  S2   DTE  or DTO expired   for details of the parameters  see  paragraph 14    9 2 1 3 Hot gas and inverted cycle defrost  Hot gas and inverted cycle defrost turns on the compressor  and opens the defrosting valve up to the conditions of  defrost end  S2 gt  DTE or DTO expired   for parameters  details  see paragraph 14    9 2 2 Types of defrost starting  The controller handles several types of defrost starting   programmable by DOP super parameter  for super  
11.  by OK key    If the password is correct  the controller allows the cold  room temperature setting    If the password is not correct  the controller displays the  message WRONG PASSWORD and returns to the Menu  item SET     7 3 Humidity setting    RH    it it hasn t been scheduled DOP super parameter  for super parameters details  see paragraph 13   the  humidity control is not enabled and  in the Menu  there isn t  the item RH     From the Menu item RH   pressing OK key  the controller  displays the message SET HUMIDITY and stops on  operating humidity set point that can be changed by  UP DOWN keys    Pressing OK key  the controller displays the message TO  CONFIRM OK  TO ESCAPE ESC    Choosing OK  the controller displays the message DONE   The value of the new set is confirmed by flashing the digits  and a short beep of the buzzer  Since then  the controller  adjusts the humidity with reference to the new set point   Choosing ESC  the controller leaves the setting of the  humidity and adjusts the temperature with reference to the  old set point        7 4 Starting manual defrost    DEF   it it hasn t been scheduled VSP super parameter  for super parameters details  see paragraph 13   the  manual defrost is not enabled and  in the Menu  there isn t  the item DEF    From the Menu item DEF  pressing OK key  the controller  displays the message TO DEFROST OK  TO ESCAPE  ESC    Choosing OK  the controller displays the message DONE  and  if there are the right conditions  it star
12.  in the pen drive root    Warning    If this file is not present in pen drive root or if it has  another name  the controller displays the message NO  FILE and it doesn t load the parameters    The controller is associated with a parameters and super  parameters setting utility  available in the DOWNLOAD  section of Smartfreeze SERVICE area   http   service smartfreeze com    7 7 3 Update firmware   From the Menu item USB UPDATE FIRMWARE  pressing  OK key  the controller starts the update procedure  if there  is the file    Vopos bin    in the pen drive root    Smartfreeze periodically releases firmware updates that  can be downloaded from its website    Warning    For firmware upgrade  use only the files released by         SMARTFREEZE  NS             Smartfreeze    Smartfreeze is not responsible for any malfunction of  the controller caused by files derived from other  sources     7 7 4 Download data   From the Menu item USB DOWNLOAD DATA  pressing  OK key  the controller starts the transfer of temperature  recorded data on the pen drive  creating the file   thermo00 csv      If in the pen drive there is another file with the same name   the controller creates a file  thermo01 csv  and so on    The controller is associated with an utility for the displaying  of temperature data recorded  available in the DOWNLOAD       section of Smartfreeze SERVICE area   http   service smartfreeze com   7 7 5 Materials    From the Menu item USB MATERIALS  with a setting file  which the re
13.  steps details  see  paragraph 10   In each test phase  by UP DOWN keys  it is  possible to get the following information  by UP key  the  phase duration in hours and minutes  by DOWN key  S2  and S3 probes temperatures and consumption in Watts     8    At the end of the test  the controller displays the message  TEST END and adjusts with reference to the setting  parameters  To delete the message TEST END it is  necessary to turn off and on the controller or to interrupt the  power supply    Warning    During the test  high and low temperature alarms are  disabled  During the test  any fault  parameter or set  point change stops the test    The controller displays the message TEST  DISCONTINUED  The restart is made by Menu  but the  message can be deleted by manual restart or by  turning off and on again the controller    Stops  black out  and starts of energy do not erase the  message TEST DISCONTINUED  In the case of black   out during the test  it remains pending and begins  again to restore supply    It is possible to stop the test  by pressing UP key for 5  seconds and the controller displays the message TEST  DISCONTINUED  which can be deleted according to the  procedure described above     8 6 D Test data    DAT   From submenu item SER DAT  pressing OK key   the controller displays the D Test report    If there aren t data  the controller displays the message NO  DATA and returns to Menu SER     EX    e START TEST M12 S22 KW 3 1   Duration and  consumption    e DEFROS
14.  with the evaporator tube bundle  allowing  the aluminium strip around the bulb of the probe itself  For  groups with hot gas defrost  the probe must be positioned  at the exit of the circuit        S3 Probe positioning set as condenser probe   Install this probe with a clamp on the outlet side of the  condenser  S3 probe manages  if enabled  the  thermoregulation fan condenser  dirty condenser notice  and the high temperature condenser alarm  S3 and S4  inputs are set as digital inputs    S3 or S4 inputs can be set as micro port digital input and  only accept clean contacts with direct or inverse logic  see  figure 2     Warning    No voltage should be applied to the digital input points  of the VOPOS Controller        18    Figure 2   S2 positioning       Humidity probe S4   After configuring the input S4 for reading humidity probe  4   20 mA type   place the probe in a position not subject to air  flows  in order to measure the real humidity of the cold  room    Observe polarity when connecting cables to the controller   see paragraph 3     Warning    Accidental polarity inversion could damage the probe  and the input circuit within the controller     15 2 Loads installation   Enter the network  from 110 to 230 Vac  to terminals of the  power controller  respecting the positions  The terminals  RL1  RL2  RL3  RL4 showing the input phase  L  when  relative relays are energized  see paragraph 3     Take care to respect load capacity of each relay to avoid  damaging the contr
15. E  0 0  40 0    defrost end temperature detected by S2  DTO  1 250 1  min   defrost maximum time   SUM  1 250 1  min   maximum pull down time admitted in  Summer   WIN 1 250 1  min  maximum pull down time admitted in  Winter   CURRENT LIMITS ICx   see paragraph 11    The D Test performs refrigerators functional and electrical   useful during the assembly and technical support phases   as it provides important elements for diagnosis    The test is divided into six phases  Ph      12    1  Stabilization    2  Thermoregulation   3  Defrosting    4  Recovery    5  Slope    6  Descent     10 1 Test starting   D Test starts from submenu item SER TST  Pressing OK  key  the controller displays the message TO START TEST  OK  TO ESCAPE ESC    Choosing OK  the controller starts the routine test and  displays the message DONE     10 2 Displaying during the test   During the test the controller displays the cold room  temperature alternated by the message that indicates the  current phase with its label  for test steps details  see  paragraph 10   In each test phase  by UP DOWN keys  it is  possible to get the following information  by UP key  the  phase duration in hours and minutes  by DOWN key  S2  and S3 probes temperatures and consumption in Watts    At the end of the test  the controller displays the message  TEST END and adjusts with reference to the setting  parameters  To delete the message TEST END it is  necessary to turn off and on the controller or to interrupt the  power sup
16. ER    pressing OK key  the  controller displays the 2 last failure events data  starting  with the most recent   If there aren t data  the controller displays the message NO  EVENTS and returns to submenu SER INF    EX      Most recent event  PROBE S2 11 08 09 10 07    e Older event  DEFROST M 03 08 09 23 57    8 4 Parameters setting    PAR   From submenu item SER PAR  pressing OK key   the controller displays the first parameter  The parameters  can be selected by UP DOWN keys  For choosing the  parameter to modify  press OK key    Then the controller displays the current parameter value   By UP DOWN keys  it is possible to select the new  parameter value and confirm it pressing OK key  The new  parameter value is confirmed by flashing the digits  a short  beep of the buzzer and then the controller displays the next  parameter  Since then  the controller adopts the new  parameter value    Choosing ESC  the controller leaves the parameters setting  and displays the last parameter selected    The exit from the submenu for parameters setting is for 4  minutes time out or by pressing MENU key for 5  seconds     8 5 D Test    TST   From submenu item SER TST  pressing OK key   the controller displays the message TO START TEST OK   TO ESCAPE ESC    Choosing OK  the controller starts the routine test and  displays the message DONE    During the test the controller displays the cold room  temperature alternated by the message that indicates the  current phase with its label  for test
17. IS IN COOLING   13 o  99 ecf 10  oaf o  HYL  UPPER HYSTERESIS IN COOLING   14  o  o oc  10  oaf o  HYC   HYSTERESIS CONDENSER FAN   is  io  o ecf 10   oaf o  DAC _ COMPRESSOR OFF DELAY   ie  i  30 secl 11  5  ADL  ANTICYCLING DELAY   iz  of 255 sec  aff 60  ASS   COMPRESSOR DELAY AT POWER ON   is  of 255 sec  ip af 60  CON  TIME COMPRESSOR ON IN PROBE FAIL   ie  o  255        af aif 3          TIME COMPRESSOR OFF IN PROBE FAIL   2o  o  255        aff 2  CPH   MAX   COMPRESSOR ON IN 24 HOURS   21  o  99    ip af 90  FAS  SET EVAPORATOR FAN IN COOLING 22  400 400   C io  0 1 100  FAD   FAN EVAPORATOR DELAY IN PROBE FAIL OR DISABLED 23 o 255 sec 1 1 60  FSD   SET EVAPORATOR FAN OFF IN DEFROST 24  99 o   C 10  0 1  40  LBT MIN EVAPORATOR TEMPERATURE 25  500 o   C io  0 1  400  DOO  DOOR OPENING TIME LIMIT  DOO 0 disable 26    255        1 1 40  FCE  SET CONDENSER FAN 27 o 600   C io  0 1 250  HYF  DIFFERENTIAL FAN CONDNESER ACTION 28 10 200   C io  0 1 50  MCT  MAX CONDENSATION TEMPERATURE 29 o 700   C 10  0 1 500  DCN   DIRTY CONDENSER THRESHOLD 30 o 300   C io  0 1 100  GAS  LOW GAS THRESHOLD 31    200   C io  0 1 20  pcm _  DIFFERENTIAL RECOVERY TEMPERATURE IN HIGH TEMPERATURE 32 o 260 m sol      ioo  RMT                   TIME IN HIGH TEMPERATURE CONDENSER 33 1 255 sec 1 1 60  PMT NUMBER OF PROTECTION EVENTS DURING TPB PERIOD 34 1 255 num 1 1 3  TPB   IME WINDOW FOR HIGH TEMPERATURE CONDENSER EVENTS 35 R pa d i i 36  DTE   TEMPERATURE DEFROSTING END 36 o 500   c 10  0 1 40  D
18. LIAN  By  UP DOWN keys it is possible to scroll other languages  items  FRENCH  GERMAN  SPANISH  AND ENGLISH   Pressing OK key  the controller displays the message TO  CONFIRM OK  TO ESCAPE ESC    Choosing OK  the controller displays the message DONE  and the cold room temperature    Choosing ESC  the controller leaves the changing  language displays the cold room temperature     7 9 Technical support functions    SER   Access to Menu item SER is under password and  is reserved for technical support     7 10 Energy meter  WAT   From the Menu item WAT  pressing OK key  the    controller displays submenu item KWH CURRENT    By UP DOWN keys  it is possible to scroll the other  submenu items  WH HOURLY and KWh DAILY    7 10 1 KWh current   From the Menu item WAT KWH CURRENT  pressing OK  key  the controller displays the value of energy totalized  from 00 01 on the current day    7 10 1 WH hourly   From the Menu item WAT WH HOURLY  pressing OK key   the controller displays the value of energy totalized in the  previous hour    7 10 1 KWh daily   From the Menu item WAT KWh DAILY  pressing OK key   the controller displays the value of energy totalized in the  previous day     SERVICE MANUAL    8  MENU SERVICE             INF Information     it shows the daily  6 and the  previous 24h 96 of compressor usage  the  calibration values and the PCB temperature    DEF  Defrost List     it shows the last 2 defrost  events     P   Failure List     it shows the last 2 failure  events   PAR  P
19. RH   10 10 1  Rh 6   dehumidification hysteresis    HPO   10 10 1  Rh    humidity reading offset    Dehumidification transfer   Dehumidification is transferred to any of the relays by  setting value 10 on relay parameter RLx  for parameters  details  see paragraph 14     Dehumidification enables the set relay when Rh 6 value   detected by the humidity probe  exceeds threshold  SetRh   HRH and it is disabled when the set humidity  value is reached     9 12 Humidification    Related parameters   HRL   10 10 1  Rh    humidity hysteresis   HPO   10 10 1  Rh    humidity operation offset  Humidification transfer   Humidification is transferred to any of the relays by setting  value 09 on relay parameter RLx  for parameters details   see paragraph 14     Humidification enables the set relay when Rh  value   detected by the humidity probe  exceeds threshold  SetRh   HRH and it is disabled when the set humidity  value is reached     9 13 Smart Climate   Related parameters   HRL   10 10 1  Rh    humidification hysteresis   HRH   10 10 1  Rh    dehumidification hysteresis   HPO   10 10 1  Rh    humidity reading offset   OSP  0  255 1  num   output configuration super  parameter    The Smart Climate is based on a new algorithm of control  that includes humidity regulation in the cold room in a  neutral area  with dehumidification in refrigerator static  condition and humidification with forced external air in cold  room  This function needs the installation of humidity  probe    In this 
20. RP   DRIPPING TIME 37 o 240 sec 1 1 o  DTO   DEFROST TIME  OUT 38 1 60 min 1 1 20  ITD  INTERVAL DEFROST 39 1 24  hours 1 1 8  SDT  ICE SENSIBILITY 40 o 50   C io  0 1 15  501  1ST DAILY DEFROST 41 o 23  hours 1 1 o  sp2  2ND DAILY DEFROST 42 o 23  hours 1 1 o  SD3   3RD DAILY DEFROST 43 o 23  hours 1 1 o  SD4   4TH DAILY DEFROST 44    23  hours 1 1 o  HOF   HUMIDITY PROBE OFFSET 45  10 10  Rh  1 1 o  HRH  DEHUMIDIFICATION HYSTERISIS 46 o 10  Rh  1 1 o  HRL   HUMIDIFICATION HYSTERISIS 47    10  Rh  1 1     CPM   MAX   COMPRESSOR IN AES HOURS 48 o 99   1 1 70  Aes _  HOURS OF COMPRESSORT SAMPLING FOR AUTOMATIC ENERGY 49 n ial ous i i 4  SPI  SETPOINT INCREASE IN NIGHT amp DAY 50 o 50   C io  0 1 10  NDS   NIGHT amp DAY START 51 o 23  hours 1 1 20  NDD  NIGHT amp DAY DURATION 52 1 23  hours 1 1 10  LGH   LIGHT OFF IN NIGHT amp DAY 53 o 1 num 1 1 o  SPX   DOOR RESISTOR SETPOINT 54  100 100   C io  0 1 30  DDR   DRAIN RESISTOR ACTIVATION TIME 55 o 240 min 1 1 15      1   CHARGE POWER IN RELE 1 56 o 1500 Watt i  10 o  PR2   CHARGE POWER IN RELE 2 57 o 1000 Watt i  10 o           CHARGE POWER IN RELE    58 o 500 watt i  10 o           CHARGE POWER IN RELE 4 59 o 500 watt i  10     SPE  SLIDING WORDS SPEED 60 3 10 num 1 1 6  STB  NUMBER OF D TEST THERMOSTATICAL CYCLES 61 1 10 num 1 1 1  CYC     NUMBER OF D TEST STABILIZATION CYCLES 62 1 10 num 1 1 2  WIN   D TEST PULL DOWN TIME IN WINTER 63 10 255 min 1 1 90  SUM   D TEST PULL DOWN TIME IN SUMMER 64 10 255 min 1 1 120  ETT  PULL UP 
21. SET IN D TEST 65  300 150   C io  0 1 100  SPU   UsER SETPOINT 66  400 400   c 10  0 1 20  OF1   PROBE 51 OFFSET 67  99 99   C io  0 1 o  OF2  PROBE S2 OFFSET 68  99 99   c io  0 1 o  OF3   PROBE S3 OFFSET 69  99 99   C io  0 1     SLL  LOWER SETPOINT LIMIT 70  400 20      io  0 1  200  SLH  UPPER SETPOINT LIMIT 71  20 400   c io  0 1 100  RHU   HUMIDITY SETPOINT SETTING BY KEYBOARD 72 10 99 Rh  1 1 75  MNS MAINS VOLTAGE 73 100 240 Volt 1 1 230  HRZ   MAINS FREQUENCY 74 50 60  Hertz i  10 50  HTB      MAXIMUM PCB TEMPERATURE 75 o 900   c 1 1 700  RLi   RELE 1 OUTPUT SETTING 76    20        1 1 o  RL2   RELE 2 OUTPUT SETTING 77 o 20 num 1 1 o          RELE 3 OUTPUT SETTING 78 o 20 num 1 1 o  RL4  RELE 4 OUTPUT SETTING 79 o 20 num 1 1 o  PSS   SERVICE PASSWORD 80 o 255 num 1 1 5  PSU  USER PASSWORD 81 o 255 num 1 1 o  SMARTFREEZE                INSTALLATION MANUAL       15  INSTALLATION      15 1 Probes installation  Temperature and humidity probes should be connected by  an insertion connector with micro screw stop     S1 probe positioning   Install the thermoregulation probe S1 preferably in a  position not subject to air flows  in order to measure the  real temperature of the cold room     S2 probe positioning   Be sure to place the evaporator probe S2  see figure 1  in  order to obtain sufficient sensitivity for detection of  temperature    For groups with reverse cycle or electric defrost  the probe  must be positioned at the beginning of the circuit and  locked in contact
22. T   HIGH CONDENSATION 65      LOW EVAPORATION  29     LOW GAS   PCB TEMPERATURE  CIRCUIT TEMPERATURE  76       TEST TIME OUT   WARNING MESSAGES   The occurrence of one of the following messages requires    attention by the user   RTY CONDESER  COMPRESSOR USAGE  NO PEN DRIVE  PEN DRIVE LOCKED   F   N    eVVVVVVVV          LE ERROR  OFILE   FULL MEMORY   LARM MESSAGES  see paragraph 6   GH TEMPERATURE   LOW TEMPERATURE    eVVVVVVV       I              6             FUNCTIONS       With reference to the            standards  Reg       852 2004   that require the continuous monitoring of  product conservation temperatures  a procedure has been  developed to record temperature alarms  divided into two  types    e high temperature inside the cold room    e      temperature inside the cold room    Monitoring probe can be S3 set as alarm probe or the  same probe set as regulation probe S1  The controller  records the last 32 events on a revolving manner while only  the last one is shown on the display  For each alarm event  the following data are recorded       duration of event    e peak temperature    e start date time of event     SMARTFREEZE          6 1 Temperature pre alarm   If there is an High Temperature pre alarm   temperature gt SPU ALH  For parameters details  see  paragraph 14   the controller displays the cold room  temperature alternated by the message HIGH  TEMPERATURE  only if it has been scheduled VSP super  parameter  for super parameters details  see paragraph  13
23. T M5 S3 KW 0 7   Defrost duration in Ph2 and  consumption     e PULL UP 230s C  PULL DOWN 668s T   Test pending i n  phases 4 and 5 in seconds degrees     8 7 Events erasing    CLR   From submenu item SER CLR  pressing OK key   the controller displays the message TO ERASE OK  TO  ESCAPE ESC  Pressing again OK key  the controller  displays the message DONE and returns to submenu  SER INF     8 8 Input Output    I O   From submenu item SER I O  pressing OK key  the  controller displays information for technical support    EX    e S1  19 7C  S2  84 8C  S3 53  5C  S4 49 RH     Temperatures read by installed probes  missing or faulty  probes are ignored   e HL1 ON  RL2 OFF  RL3 OFF  RL4 ON   State of relays RL  1234    v If S3 is configured as digital probe or it is not  installed  the related information are not displayed   v If S4 is configured as digital probe or it is not  installed  the related information are not displayed     8 9 Firmware version    FW   From submenu item SER FW  pressing OK key   the controller displays the firmware version and returns to  submenu SER INF    8 10 Controller serial number    SN   From submenu item SER SN  pressing OK key  the  controller displays its serial number and returns to  submenu SER INF        SMARTFREEZE  NS          9  CONTROLLER ACTIONS          9 1 Cooling    Related parameters   SET    40 0  40 0 0 1     set point settable from user  menu   HYH    0 0  10 0 0 1       adjustment top hysteresi s point  HYL    0 0  10 0 0 1      
24. ads compared to a pre set tolerance     11 2 Daily control on each load   The policy provides that  at the first transition on  gt  off of the  cooling relay after 00 00 hours  the setting is locked for  LDA seconds  Scheme 1  step 1  and then the relay are  enabled in sequence  Scheme 1  step 2   for parameters  details  see paragraph 14     Subsequently  Scheme 1  step 3   the verification of power  consumption on each relay is enabled with the method of  removal of loads  measuring the decrease of power    If it is a value outside the range of tolerance for expected  consumption or it is detected non zero consumption  the  failure is stored and displayed the message LOAD  RLX   without setting changes     11 3 On demand control of total power consumption by  each load   If there is a temperature alarm or a failure  except dirty  condenser  or if the consumption verification exceeds the  expected one  the controller repeats the daily routine total  power consumption     Scheme 1       Regulation    off and  after 00 00 setting  relay off    relay on    i    RL2    dial    RL3    RL4    Ore 00 00  Compressor on  Ore 00 00  Compressor  off       pue ADL  1  transition on  waiting 2 Subsequently setting    Regulation restarting  RL1 w3  I    3 Power consumption detection  method of removal of loads    we      wi             SMARTFREEZE             14         FUNCTION FAILURES VS  WORKING MODES          Thermoregulation Average time cycles on thermoregulation or    Detected Val
25. and by mode   displaying the symbol        Choosing ESC  the controller leaves the turning off and  returns to operation mode    If PSU parameter is  gt 0  for parameters details  see  paragraph 14   before the turning off  the controller displays  the message PASSWORD and stops on the three digits  000  The PASSWORD is setting by UP DOWN keys and  confirmed by OK key    If the password is correct  the controller turns off    If the password is not correct  the controller displays the  message WRONG PASSWORD and returns to the Menu  item OFF     7 2 Cold room temperature setting    SET   From the Menu item SET  pressing OK key  the  controller displays the message SET TEMPERATURE and  stops on the operating temperature set point that can be  changed by UP DOWN keys     SMARTFREEZE                Pressing OK key  the controller displays the message TO  CONFIRM OK  TO ESCAPE ESC    Choosing OK  the controller displays the message DONE   The value of the new set is confirmed by flashing the digits  and a short beep of the buzzer  Since then  the controller  adjusts the temperature with reference to the new set point   Choosing ESC  the controller leaves the temperature  setting and adjusts the temperature with reference to the  old set point    If PSU parameter is  gt 0  for parameters details  see  paragraph 14   before the temperature setting  the  controller displays the message PASSWORD and stops on  the three digit 000  The PASSWORD is setting by  UP DOWN keys and confirmed
26. arameters setting     it allows the parameters  setting   TST  D Test     it starts routine test   DAT  D Test Data     it shows the data test   CLR    Erasing Events     It erase memory  events   1 0  Input Output     it shows probe temperature and  relays RL1  RL2  RL3  RL4 condition   FW  Firmware Version     it shows firmware  version   SN    Controller Serial Number     it shows the  controller serial number               SMARTFREEZE  VN             8 1 Information    INF   From submenu item SER INF  pressing OK key   the controller displays information for the technical support    EX   e 1h 45  24h 67      Compressor usage in the last hour  and in the last 24 hours   6 not calculated      E MIN 23C  MAX 34 C CYCLES 06   Calibration values    min and max evaporation and number cycles for  calibration     e DELTA 18C RANGE 65T 34C   Average adjusted  value of condenser thermal exchange and min max  adjusted values in detection criteria of dirty condenser    e BOARD 76      Vopos board temperature      8 2 Defrost List    DEF   From submenu item SER DEF  pressing OK key   the controller displays the 2 last defrost events data   starting with the most recent   If there aren t data  the controller displays the message NO  EVENTS and returns to submenu SER INF    EX      Most recent event  MINUTES 012 23 45 03 08 09 M101      Older event  MINUTES 008 10 49 03 08 09 M09    For the details of defrost causes  MXX  see paragraph 9 9     8 3 Failure List        From submenu item S
27. ched    During defrost  condenser fans can be set on  off or   thermo regulated according to FOP super parameter  for   super parameters details  see paragraph 13      9 5 Micro door action on loads    Related parameters   ISP  0  255 1  num   configuration super parameter on   inputs   DOO  0  255 1  sec   door open maximum time allowed   9 5 1 Logic        ISP super parameter  for super parameters details    see paragraph 13   it is possible to enable S3 or S4   inputs as micro door digital input normally open or   closed    When a door opening is detected  the controller displays   the message OPEN DOOR    The related actions to this event are the followings    a the evaporator fan is turned off while the compressor  output is unaffected    b light on mode is enabled and transferred to the relay with  action 05    C  spent DOO  the fan is enabled  the light is turning off and  set the alarm CLOSE DOOR    At door closing  evaporator fans start again with a 10   seconds delay     9 6 Cold room light action    Related parameter  OSP  0  255 1  num   configuration of super parameter on  outputs             Cold room light action transfer   Cold room light action is transferred to any of the relays by  setting value 05 on relay parameter RLx  for parameters  details  see paragraph 14  and by setting  with OSP super  parameters  for super parameters details  see paragraph  13   UP key as light     9 7 Anti Ice resistance action    Related parameter  SPX   10 10 1        temperat
28. er stops the D Test and  displays the message DEFROST TIME OUT        x SMARTFREEZE             10 3 3 Test ending for failure   During the test  any fault stops the test  The management  of the alarms and the evaporator temperature alarm are  disabled    If the test ends for failure  the controller displays the  message TEST DISCONTINUED  To delete the message   it is necessary to turn off and on the controller or to  interrupt the power supply    10 3 4 Test ending for parameter change   During the test  any parameter change  including the set   point  stops the test    If the test ends for parameter change  the controller  displays the message TEST DISCONTINUED  To delete  the message  it is necessary to turn off and on the  controller or to interrupt the power supply    10 3 5 Test ending from the keyboard   D Test can be stopped by pressing for 5 seconds the UP  key  The controller returns to the operation mode and  displays the message TEST DISCONTINUED     10 3 6 Regular test ending   At the end of the test  the controller displays the message  TEST END and starts the regulation according to the  setting parameters    To delete the message  it is necessary to turn off and on  the controller or to interrupt the power supply        10 4 Special conditions   10 4 1 Drip and recovery   Drip  wait for compressor restarting after defrost  is  counted in the recovery phase  Data displayed is net of this  time    10 4 2 Test restarting after power supply   After an interruptio
29. ers are free from electromagnetic  emission according to EEC Directives  To reduce  the causes of disorders such radiated or  conducted  which can propagate through the  probes  loads and controller power supply  you  must do the wiring of the cables preventing their  passage close to the absorption of high loads or  sources of electromagnetic disturbances     lt necessary to put temperature probes in contact  with food  verify that these comply with food and  health requirements     If the controllers will be installed in devices whose  malfunctioning may generate hazard for people   animals or things  it must be adopted extra safety  systems that operate independently of the  controllers     2 1 Mechanics  P   ABS case  size 32x 4mm  2 2 Supply     gt  Switching 110 230V 50 60Hz with an input for back up   12V cc 5V cc     2 3 Probes inputs Range     51         thermoregulation   50 0   50 0C  0 10       50 0   50 0     0 10  9 53         condenser alarm   20 0   80 0 C  0 1 C            Resolution    S2  ntc evaporator    S4  digital 4 20mA  10 99 Rh   1   Internal current probe  0 20A  0 1A  2 4 Rel   outputs  P    4rel   20A 8A 5A 5A  one is a switch N C  N A    2 5 User interface   gt  Touch pad with 4 keys and a menu configuration         Led display with 3 alphanumeric digits 7x5 segments   for a total of 7x15 dots  and with sliding words    2 6 Communication        RS485 to connect to local networks and Smartfreeze  Unit  SFU  for remote Monitoring and Control       
30. frigerator manufacturer would have  it is  possible to add the list of refrigerator materials  refrigerator  bil   with their PART NUMBER and descriptions    7 7 6 Start up   This menu item is disabled to the user and is restricted to  Smartfreeze for the controller startup procedure     7 7 User password setting    PAS   From the Menu item PAS  pressing OK key  the  controller displays the message SETUP PASSWORD and  stops on the three digits 000 that can be changed by  UP DOWN keys    Pressing OK key  the controller displays the message TO  CONFIRM OK  TO ESCAPE ESC    Choosing OK  the controller displays the message DONE   The value of the new PASSWORD is confirmed by flashing  the digits and a short beep of the buzzer  Since then  the  controller allows the access to protected functions just by  setting the new password    Choosing ESC  the controller leaves the password setting  and displays the cold room temperature    If PSU parameter is  gt 0  for parameters details  see  paragraph 14   before the password setting  the controller  displays the message PASSWORD and stops on the three  digits 000  The PASSWORD is setting by UP DOWN keys  and confirmed by OK key    If the password is correct  the controller allows the  password setting    If the password is not correct  the controller displays the  message WRONG PASSWORD and returns to the Menu  item PAS     7 8 Changing language    LAN   From the Menu item LAN  pressing OK  the  controller displays the language item ITA
31. function  temperature control is most important than  the humidity one    9 14 Humidity control without probe   RH  10 99 1  Rh    humidity set point   In refrigerators with positive temperature  humidity control  is possible without a probe  It is enabled by adding weight 8  to the FOP super parameter  for super parameters details   see paragraph 13     By correlation tables between compressor time and  evaporator fans time  it is set the relative percentage of the  cold room  Minimum Rh  set is 60   maximum is 90    For relative humidity values set between 60 and 75   fans  evaporator output is off during the compressor pause   When compressor is on  evaporator fans have a trend of  turning on turning off for 60 seconds     x SMARTFREEZE          For relative humidity percentages set between 75  and  9096  fans evaporator output is always on during the  compressor turning on  during the compressor pause  fans  evaporator output is on for a time proportional to the  average pause time of the compressor     9 15 Relay alarm action    Relay alarm action transfer   Relay alarm action  in its various configurations  is   transferred to any of the relays by setting the following   values on relay parameter RLx  for parameters details  see   paragraph 14         relay set with value 11 remains normally closed and  opens when there is an alarm  and IT IS NOT  POSSIBLE buzzer turning off        relay set with value 12 remains normally closed and  opens when there is an alarm  and IT
32. hoosing ESC  the controller leaves the turning on and  returns to stand by mode    If PSU parameter is  gt 0  for parameters details  see  paragraph 14   before the turning on  the controller displays  the message PASSWORD and stops on the three digits  000  The PASSWORD is setting by UP DOWN keys and  confirmed by OK key    If the password is correct  the controller turns on    If the password is not correct  the controller displays the  message WRONG PASSWORD and returns to stand by  mode     5 2 Normal displaying mode   In normal displaying mode  the controller displays the cold  room temperature  Probe S1  or the probe alarm  temperature  depending on the configuration chosen by the  manufacturer    The temperature scale will be shown in tenths of degree  Celsius with a minus sign  only for negative values  for a  range between  29 9   C and  69 9    Below the lower  limit  the temperature appears with    sign and scale    If the compressor is activated  temperature displaying is  alternating by the message COOLING or  in defrost case   by the message DEFROST     5 3 Displaying mode in case of event   If fault  warning or alarm occur  the controller displays the   event alternated by the cold room temperature until the   event is corrected  with an option to append more events    e MESSAGES OF FAILURE  variables are shown in  bold italics    The occurrence of one of the following messages requires   a technician intervention    PROBE FAIL Sx   LOAD  RLx    DEFROST TIME OU
33. n of the power supply occurred during  the test  it restarts from the beginning    10 4 3 Memory reset   The controller memory reset does not cancel the D Test  data        10 5 D Test data displaying   From submenu item SER DAT  pressing OK key  the  controller displays the D Test report  The controller leaves  the report pressing MENU key or after 2 minutes of time  out  The controller displays the report again pressing  DOWN key    If there aren t data  the controller displays the message NO  DATA and returns to Menu SER     13    EX    e START TEST M12 S22 KW 3 1   Duration and  consumption    e DEFROST M5 S3 KW 0 7   Defrost duration in Ph2 and  consumption     e PULL UP 230s T   PULL DOWN 668s C   Test pending in  phases 4 and 5 in seconds degrees    10 6 D Test data cancellation  D Test data cancellation is possible only by overwriting the  most recent data  after starting a new test     11  ELECTRICAL LOADS CONTROL       Associated parameters   PR1 power used by load on a RL1    0 1500  W   default  OW   step 10W   PR2 power used by load RL2    0 1000  W   default OW    step 10W   PR3 power used by load on RL3    0 500  W   default OW    step 10W   PR4 power used by load on a RL4    0 500  W   default  OW   step 10W   Maximum measured load is 2500 Watts    If Pri 0 this control is disabled     11 1 Real time control of total power consumption  During the operation mode  the controller monitors total  power consumption which should not exceed the sum of all  allowed lo
34. oller     15 3 Outscan Function   If in stand by mode  the display shows the following  symbols            are simultaneously pressed the MENU    DOWN INFO keys for 2 seconds  for details of the  keyboard  see section 4   the controller enables the  procedure that turns on sequentially loads for 3 seconds  each and reads the connected probes  After scanning  the  controller returns to stand by mode    During the sequentially turning on of the loads  the  controller estimates  with reference to the current  consumption  the power consumption on each relay and  displays it  After 500ms of delay  a higher or lower power  Prx  for details of the parameters  see section 14  requires  the immediate exit from the function with loads locked until  the controller turning off and its turning on    When running Outscan  the display shows consumption in  Watts     ON OFF READINGS AND DISPLAYING                                                                                          RLI ON       Watt xxx RL2 ON          W att                                       oOOn                         A   AARA  A      AAAAAAA   R    RL3 ON Watt        RL4 ON Watt xxx                SMARTFREEZE             SNARTFREEZE    Via delle Conce  20  00154 Roma  Tel   39 06571 763301  Fax  39 06571763400  www smartfreeze com  info smartfreeze com       SMARTFREEZE       19    
35. parameters details  see paragraph 13    The interval between defrosts is expressed by ITD  parameter  for parameters details  see paragraph 14    Defrost starts in different ways  whose index m is shown in  the defrost list  viewable by the submenu item SER DEF   see paragraph 8   Defrosts  which can occur with or  without evaporator S2 probe installed  are as follows    m1 manual defrost by keyboard   m2 defrost by serial command   m3 automatic defrost at every IDT hours   m5 automatic defrost at RTC time   m6 automatic defrost by D Test   m7 automatic defrost in absence of calibration data   m8 automatic defrost by insufficient evaporation   m9 automatic defrost by excessive evaporation   m10 automatic defrost by calibrated protection   m11 automatic defrost by time protection   m12 automatic protection defrost by low temperature   evaporation  9 2 2 1 M1  Manual defrost by keyboard  Manual defrost is enabled by the right value of DOP super  parameter  weight 1   for super parameters details  see  paragraph 13  and it starts by menu item DEF  see  paragraph 7    Electric Defrost  It starts immediately if the S2 evaporator temperature is  less than DTE  for parameters details  see paragraph 14      Hot gas defrost   It starts when set point is reached  if the S2 evaporator  temperature is less than DTE with DOP parameter weight  64  for super parameters details  see paragraph 13    Where set point value is not reached within a maximum  time of 20 minutes after manual defrost
36. ply    Warning    During the test  high and low temperature alarms are  disabled  During the test  any fault  parameter or set  point change stops the test    The controller displays the message TEST  DISCONTINUED  The restart is made by Menu  but the  message can be deleted by manual restart or by  turning off and on again the controller    Stops  black out  and starts of energy do not erase the  message TEST DISCONTINUED  In the case of black   out during the test  it remains pending and begins  again to restore supply    It is possible to stop the test  by pressing UP key for 5  seconds and the controller displays the message TEST  DISCONTINUED  which can be deleted according to the  procedure described above     10 3 Test ending    10 3 1 Test ending for not reaching set   The controller stops the D Test if  during the turning on or  the thermoregulation  doesn t reach the set point in WIN  minutes in winter or in SUM minutes in summer  for  parameters details  see paragraph 14   In this case  the  controller displays the message SET NOT REACHED    The selection of WIN  SUM parameter is made with  reference to this condition  if  at test starting  S1 probe  detects a temperature  gt 20  C  the controller selects the  parameter SUM  if S1 probe detects a temperature   20 C   the controller selects the parameter WIN    10 3 2 Test ending for not reaching of end defrost  temperature   If  during test phase Ph3  S2 probe doesn t reach DTE C  value in DTO minutes  the controll
37. rameter BUR  for parameters details  see paragraph 14   represents the time  in minutes  of buzzer reiteration  The  reiteration implies the buzzer reactivation  after the buzzer  has been stopped by the key board  with the alarm still  persisting    With the parameter BUR 0  the buzzer reiteration is  disabled    Parameter BUF  for parameters details  see paragraph 14   sets the time the buzzer will sound  without the turning off   After BUR time  the buzzer starts again and gets repeated  after BUR minutes    If BUF 0 buzzer stays on until the alarm end        7  USER MENU DESCRIPTION          User Menu is accessible by pressing the MENU key  for  scrolling each item use UP and DOWN keys    Below is a list of features visible using the DOWN key   Warning    The items listed by the dotted are viewable only if their  function is previously enabled           OFF Controller switching off    SET Cold room temperature setting    Rh  Humidity setting    DEF Starting manual defrost    DOO Door traffic displaying    Date Time setting    0 0 H12 M19 D06 M02 Y10    USB Pen drive functions    PAS User password setting  LAN Changing Language  SER    Technical support functions    WAT Energy meter       7 1 Controller turning off    OFF   in the operation mode  pressing MENU key  the  controller displays the message OFF    Pressing OK  it displays the message TO TURN OFF OK   TO ESCAPE ESC    Choosing OK  the controller displays the message DONE   BYE  Then it turns off and returns to st
38. rameters values  If it has been  scheduled PSO super parameter  for super  parameters details  see paragraph 13   the key   pressed for 2 seconds  enables the function LIGHT  and allows to turn on  LIGHT ON message  and off the  light  LIGHT OFF message     e DOWN INFO KEY  in normal display mode  it enables  the DOWN function  after the selection of MENU for  scrolling by menu and submenus items  It decreases  the SET POINT and or parameters values  It enables  INFO function  when it is pressed for 2 seconds  and  enables the information string with the   of operating  compressor in the last hour  of the evaporator and  condenser temperatures  if enabled   of the  instantaneous consumption and  ultimately  of the last  temperature alarm data  if it happened  alarm type   maximum temperature for high temperature alarm and  minimum temperature for low temperature alarm  with  date  time of start event     EX  WITH RECORDED ALARM   e K45   TE  24C TC 56C  WATT 230  HIGH  TEMPERATURE  MINUTES 12  MAX  23C  12 08 09  23 56   EX  WITH NOT RECORDED ALARM  if   non calculated            e K45   Te 24C  Tc 56C  WATT 230    5 1 Controller turning on   To turn on the controller  in stand by mode  the display  shows the following symbol       pressing any key for longer  than 2 seconds    The controller displays the message TO TURN ON OK  TO  ESCAPE ESC    Choosing OK  the controller displays the message DONE   WELCOME and starts to adjust  displaying the cold room  temperature        C
39. reduces energy consumption when  compressor usage percentage reaches a set value  In this  condition the operating set point is increased by SPI C  for  parameters details  see paragraph 14  and then re   established to the set conditions    9 9 1 AES on   After AES consecutive hours  during which the compressor  usage percentage is  gt  or   to the CPM percentage  the set   point changes to  SET   SPI   for parameters details  see  paragraph 14     9 9 2 AES off   After AES consecutive hours  during which Automatic  Energy Saving is on  with the compressor usage hourly  percentage    to the CPM percentage  the controller  restores the original set point     9 10 Night amp Day  N amp D     Related parameters   NDS  0  24 1  hours   activation time of function Night amp Day  NDD  0  23 1  hours   duration of function Night amp Day   SPI  1  5 1  C   increase in degrees of operating s et point    11    LGH  0  1 1  flag   light state unchanged or forced off in  Night amp Day   This function  enabled by OSP super parameter weight 32   for super parameters details  see paragraph 13   starts  every day and reduces cold room consumption  increasing  the set point by SPI C  starting from an hour set by NDS  parameter for a duration of NDD hours  for parameters  details  see paragraph 14     During H amp D mode  if LGHz1  the light mode is forced off  if  LGH 0  light mode remains unchanged  for parameters  details  see paragraph 14      9 11 Dehumidification    Related parameters  H
40. splays the message MEMORY RESET    If PSU parameter is  gt 0  for parameters details  see  paragraph 14   before the Data Time setting  the  controller displays the message PASSWORD and  stops on the three digits 000  The PASSWORD is  setting by UP DOWN keys and confirmed by OK key    If the password is correct  the controller allows the  Date Time setting    If the password is not correct  the controller displays  the message WRONG PASSWORD and returns to the  Menu item 0 0     7 7 USB functions    USB   Warning    Before entering this Menu item  put the pen drive  with  its adapter  in controller USB port    From the Menu item USB  pressing OK key  the controller  displays the submenu item SAVE PARAMETERS  By  UP DOWN keys  it is possible to scroll other submenu  items  LOAD PARAMETERS  UPGRADE FIRMWARE   DOWNLOAD DATA  MATERIALS  STARTUP    If the pen drive isn t on  the controller displays the message  NO PEN DRIVE    If the per drive is on  but it is write protected  the controller  displays the message PEN DRIVE LOCKED    7 7 1 Save parameters   From the Menu item USB SAVE PARAMETERS  pressing  OK key  the controller saves parameters in the pen drive   creating the file    param00 par       If in the pen drive there is another file with the same name   the controller creates a file    param01 par    and so on    7 7 2 Load parameters   From the Menu item USB LOAD PARAMETERS  pressing  OK key  the controller updates the parameters  read from  the file  param par  that is
41. t     TTS       4 Defrost every ITD hours disabled     7    Operation with x weight  P r e                  ci                16 Defrost at RTC time disabled     7  32 Protection defrost disabled     TTS     64 Immediatedefrost start    TTTS     128 Automaticdefrost disabled     TS    ie a TT    7 SMARTFREEZE                                                                                                                                                                                                                                                                                                       17  14  PARAMETERS  COD PARAMETER POSITION LOWER UPPER UNIT SCALE STEP DEFAULT  LIMIT LIMIT  ADR  SERIAL ADRESS o  0 255 num ip af 2  VSP   USER INTERFACE SUPER PARAMETER   i  of 255 num   il af o  ISP   INPUT SETUP SUPER PARAMETER   2  o  255 num  ip al o  OSP  OUTPUT SETUP SUPER PARAMETER        o  255 num  ip af o  FOP   FANS SETUP SUPER PARAMETER   af of 255 num  ip af o  DOP  DEFROST SETUP SUPER PARAMETER   s  o  255 num  11  o  ALH   HIGH TEMPERATURE DIFFERENTIAL   e  o  500 ecf 10  oaf 60  ALL  LOW TEMPERATURE DIFFERENTIAL   7    soo  o        10  oaf  30  ALD   ALARM DELAY IN REGULATION   s  i  240        aff 20  ADS   ALARM DELAY AT POWER ON   of i  240 mint f af 90  ADF   ALARM DELAY AFTER DEFROST   io  i  240        af af 30  BUR   TIME BUZZER REITERATION   ii  o  255 mint ip af 30  BUF   TIME BUZZER PERSISTANCE IN ALARM   12  of 255        il af 5          LOWER HYSTERES
42. t  the condenser fans follow this rule    v Fan ev  OFF  S2 gt   SET FSD  v                ON  S2   SET FSD 5C   9 2 5 Dripping  defrost end   When temperature reaches DTE  for parameters details    see paragraph 14  output enabled by action 02 is disabled    From this moment  the controller may or not start the   dripping  defrosted water drainage  depending on DRP   parameter set  for super parameters details  see paragraph   13   DRP 0 avoids the dripping  while DRP 20 starts the   dripping with loads off  for DRP seconds                 9 3 Evaporator fans action    Related parameters   FOP  0  255 1  flag  configuration super parameter   FAS   20  20 1       fan activation consensus regulat ed  FSD   40  10 1       fan off set during defrost   FAD  0  255 1  sec   fan time delay from start o defrost S2  HYF  1  20 0 1       isteresi ventole in regolazion e   LBT    0 1       evaporator low temperature limit   DOO  0 255 1  sec   t max turn off time with open doors  Evaporator fans action transfer   Evaporator fans action is transferred to any of the relays by  setting value 03 on relay parameter RLx  for parameters  details  see paragraph 14     9 3 1 Fan in parallel with compressor       With this configuration the evaporator fans will have main    x SMARTFREEZE    10    consensus only with compressor on during the cooling   Otherwise they will remain off    In addition to the main consensus  the evaporator fans are  subject to the following conditions      on for S2   
43. ts defrost and  displays the message DEFROST    If there aren t the right conditions for defrost  the controller  displays the message ACCESS DENIED and the  temperature  If defrost is pending  the controller displays  the message WAITING DEFROST alternated by the  temperature until the defrost starting    Choosing ESC  the controller leaves the defrost and  displays the cold room temperature           7 5 Door traffic displaying    DOO   i it hasnt been scheduled DOO super  parameter  for super parameters details  see paragraph  13   the monitoring of door openings is not enabled and  in  the Menu  there isn t the item DOO   From the Menu item DOO  pressing OK key  the controller  displays the door traffic list of the 2 last days    ES    e OPENING FOR MINUTES TODAY 034 021 CRITICAL 001    OPENINGS 11 08 09 012 FOR MINUTES 000     6    If there aren t door traffic events  the controller displays the  message NO EVENTS     7 6 Date Time setting    0 0   From the Menu item 0 0  pressing OK key  the  controller displays time digits that can be changed by  UP DOWN keys    Pressing OK key  the controller displays progressively  minute digits  day  month and year  The confirmation of the  selected data is set by pressing OK key    Pressing ESC key  the controller leaves the data time  setting in every phase  hour H  minutes M  day D  month M   year Y    Warning    Confirming the value of the year Y  date time setting  causes the automatic memory cancellation and the  controller di
44. ues out of                         i PROBE S1 i probe faulty or i i transfer of adjustments to probe if calibration i  i DEN i range         i missing i   data Temin Temax are present         Evaporator probe   Detected values out of   Timed DEFROST every ITD hours for the duration      PROBE S2    Sn     5 i      faulty or missing i range i of DTO minutes      Nurse   Condenser probe   Detected values out of   Cuts out reading as if probe were not fitted and      i faulty or missing   range i sets fans in parallel wit compressor    i PROBE S4   Humidity    probe   Detected values  out OF i Cuts out reading as if probe were not fitted         faulty or missing   range        E   Evaporator LOW i iere Else    EVAPORATION   TEMPERATURE      pU RIT De        i records event and turns compressor OFF with                  ENCE time otherwise returns to normal regulation      HIGH   Condenser HIGH   53 gt MCT  C   Stops regulation activating fans only to reach    i CONDENSATION   TEMPERATURE   i temperature MCT 10  C measured by PROBE S3      DIRTY    453  gt 0     during           CONDENSER   Dirty condensed           No action  warning only on display     i COMPRESSOR   High usage of   Active for CPH  in the i o Maiani      USAGE i compressor i 24 hours            PM           i Temperature DTE not           DEFROST M   Excessive defrost   reached      time DTO   Warns that during DEFROST temperature DTE      i time    i was not reached within        time            minutes      
45. ure for ice resistor    Cold room light action transfer   Anti Ice resistance action is transferred to any of the relays  by setting value 07 on relay parameter RLx  for parameters  details  see paragraph 14     9 7 1 Logic   Anti Ice resistance action enables relay set with value 07 if  S1 probe detects a temperature S1 lt  SPX   and disables  it when temperature condition is S1 gt   SPX 2  C    In other word  load is controlled in warm action with  hysteresis of 2C     9 8 Condensation discharge resistance action  Related parameters  DDR  0  240 1  min   turn off delay after a defrost    Condensation discharge resistance transfer   Condensation discharge resistance action is transferred to  any of the relays by setting value 08 on relay parameter  RLx  for parameters details  see paragraph 14      9 8 1 Logic   The turning on of condensation discharge resistance starts  with defrost beginning and ends after DDR minutes  for  parameters details  see paragraph 14   It has the aim to  heat the defrost water drainage pipe that otherwise would  remain frozen and would not allow the conveyance of water  on the drip tray     9 9 Automatic Energy Saving  AES     Related parameters   AES  1  12 1  ore   time to sample 96 compressor on   CPM  50  99 1      threshold 96 compressor ON triggered  by AES   SPI  1  5 1       temp increase of operating set poin t  Automatic Energy Saving function  enabled by OSP super  parameter weight 16  for super parameters details  see  paragraph 13   
    