1. Light bar range 15 segments logarithmic scale corresponding to threshold setting Audio Feedback per channel Tones Piano continuous clicks Raw Volume Levels 0 TO 7 Audio provided Continuously Above or below threshold after 3 or 5 seconds Statistics per channel Statistics aquired summary Min Min Mean SD SD time gt or lt threshold Statistics aquired intra stats Choice Min Max Mean SD SD otime gt or lt Threshold of Sampling Capacity 30 to 300 minutes of data depending on the sampling rate Intra session data collection rate 0 5 1 0 2 5 0r5 0 minutes Data Display Rate 2 5 seconds 4 Hz every 0 25 seconds of V RMS Electrical per channel Resolution 0 100V Bandpass 24 425 Bandpass Rolloff 18 dB per octave Common mode Rejection 120 dB Notch Filter 60 Hz 25dB 50 Hz option Differtial Input Impedence amp input noise gt 1 000 000 megohms 0 3nV Leakage Current In compliance with UL2601 specifications Audio output 3 5 mm stereo earphone jack mono output Analog output Linear 0 3 volt DC signal compatible with most computer interfaces Line power Input 120 volt 60 HZ 220V 50 60 Hz Battery Longitivity Rating 10 to 12 hours continuous use Battery Recharge 16 hours maximum with built in overcharge protection STANDARD ACCESSORIES e UL listed isolation adapter e Installed N
2. Chinta Se mukti HOSPITAL PEENYA Industrial Suburb Bengaluru 560 022 e mail esichpeenya gmail com Telefax No 080 23579467 EMPLOYEES STATE INSURANCE CORPORATION Under Ministry of Labour amp Employment Govt of India Sy No 11 55 1 Plot No 1 5 Main FTI Campus Yeshwanthpur No 492 U 16 30 2012 Central Stores TENDER NOTIFICATION Sealed and superscribed tenders are invited from reputed Manufacturers or their sole authorized dealers in prescribed tender forms for SUPPLY INSTALLATION COMMISSIONING amp MAINTENANCE OF MEDICAL EQUIPMENTS TO VARIOUS DEPARTMENTS The list of medical equipment is as under LIST OF MEDICAL EQUIPMENTS Dated 31 07 2012 Perf SI No Tender No Name of the Equipment Qtt FMD BG In Rs In Rs GROUP 1 LABORATORY 1 NO 492 U 16 30 2012 A 1 LAB Digital Incubator 1 1250 2500 Trinocular microscope with 2 NO 492 U 16 30 2012 A 2 LAB photomicrography and 1 14000 28000 facility for upgradation Slide Cabinet 50000 3 NO 492 U 16 30 2012 A 3 LAB SI 1 2500 5000 4 NO 492 U 16 30 2012 A 4 LAB Binocul r microscop with 4 10000 20000 illumination 5 NO 492 U 16 30 2012 A 5 LAB Hot Air oven 1 1000 2000 6 NO 492 U 16 30 2012 A 6 LAB Centrifuge 3 4500 9000 Semi Automated 7 NO 492 U 16 30 2012 A 7 LAB 1 5000 10000 U 16 30 AM 7 coagulation Analyser GROUP 1 GENERAL SURGERY
3. Original Instrument not refurbished User certificate to be given AMC to be provided SLIDE CABINET No 492 U 16 30 2012 A 3 LAB Stainless steel rust proof Capacity 50 000 Slides Sturdy To be provided with lock and key BINOCULAR MICROSCOPE SPECIFICATION No 492 U 16 30 2012 A 4 LAB Infinity plan objectives 4X 10X 40X SL 100X SL Oil Eye piece WF 10X FOV 22mm Focusable type Anti fungal treat head free HEA Coated optic Single mould study ergonomic design stand Universal infinity optical system quadraple reverse Non piece Binocular head inclined at 30 degree scaled inter Papillary distance Illumination LED Halogen with controls and built in battery backups of approximately 2 hours Packed in styrofoam moulded box Smooth CAM technology co axial control coarse and fine focusing Rackles X axis double plate stage double slide holder X 4 to travel range 76x50 mm Abbe condenser NA 1 25 with aspheric lens and aperture iris diaphragm After sale service should be best in the industry with service engineer based in Bangalore AMC to be provided and calibration to be given every six months CMC for 5 years and Warranty for 2 years HOT AIR OVEN No 492 U 16 30 2012 A 5 LAB Internal size 45cm X45cm Door Single door No of shelves two adjustable at any Height Door filter on heavy brass heat and Chrome plated hinges and brass west Chrome plated spring type lock handle Cabin Inside made up of
4. High infant temperature Low infant temperature Probe failure Heat failure Power failure Spo2 High and Low alarm 1 Battery Low alarm System failure with automatic heater cut off Heater Element Single element quartz infrared heating element placed in a parabolic reflector Heater output control range Manual 0 100 Suction control should be provided Internal weighing scale Optional Range 0 10 kg Accuracy 10 gm Should be provided with integrated Pulse Oxymeter optional Oxygen saturation range 1 100 Pulse rate range 25 250 BPM Should have an integral n CPAP Optional with following features Should be supplied with bonnet and cap for correct fixation of nasal prongs Should be supplied with 3 sizes of prongs Small Medium and Large at least one each Should be supplied with porper air and Oxygen blender and not air and oxygen flow meter to mix gas Should be provided with PEEP Generator near baby to ease respiratory effort by baby and reduce dead space Should be provided with digital manometer 0 99 cm of H20 Should have I V stand Both side Myo tray 2 nos on same side Oxygen cylinder index optional Should have an oval shaped bed for greater accessibility and without crevices for ease in cleaning Should have a firm antibacterial matters Should have LCD Graphical Display Should have the provision to take X rays with help of portable X ray machine without shif
5. Should have a tray and a draw for keeping essential of the baby below the infant bed Should have aAPGAR timer that alerts every minute Should have a warmer controller with pre warm and manual mode of operation Should indicate infant temperature with following specification Range 20 to 45 degree Celsius Accuracy 0 2 C Resolution 0 1 C Interchangeability 0 1 C between sensors Manual mode of operation should be limited to 15 min at power above 80 to the heater The unit should cut off heated to a safe level and trigger an alarm on elapse of 15 min in manual mode with power above 80 Should have a resuscitation unit with following specification Oxygen outlet 1 No Flow meter 0 12 lpm with 0 5lpm graduations Oxygen tube of 2 m length Slow suction 0 200 mm Hg Adjustable with vacuum gouge indication Poly carbonate jar with 600ml capacity Should work on venturi principle Autoclavable tubing to be provided Should be supplied with 1 No patients skin temperature probe The mattress should be easily removable for cleaning and made of anti bacterial and flame retardant cover The manufacturer should have ISO 9001 2000 and ISO 13485 certification H DERMATOLOGY LIQUID NITROGEN CRYOJET MACHINE NO 492 U 16 30 2012 H 1 DERMA LIGHT WEIGHT HIGH QUALITY DEWAR FLASK ACCESSERIES DIFFERENT PROBES SHARP BEWEL EDGE FLAT STRAIGHT Acne spray contact adopter with tips Liquid nitrogen stora
6. 1 NO 492 U 16 19 2012 B 1 SURG LED Mobile O T Light 7 17500 35000 2 NO 492 U 16 19 2012 B 2 SURG OT TABLE FOR MINOR OT 1 50000 100000 GROUP 1 PEDIATRICS Electronic digital weighi 1 NO 492 U 16 30 2012 F 1 PED SCU ONIG lela WEIBDINE scales NO 492 U 16 30 2012 F 1i PED 1 Neonate 2 2000 4000 NO 492 U 16 30 2012 F 1ii PED ii Infant amp Child 2 2000 4000 2 NO 492 U 16 30 2012 F 2 PED Ophthalmoscope 2 1500 3000 3 NO 492 U 16 30 2012 F 3 PED Cutaneous bilirubinometer 1 8750 17500 Double surface CFL 4 NO 492 U 16 30 2012 F 4 PED Phototherapy 4 14000 28000 5 NO 492 U 16 30 2012 F 5 PED Neonatal open care system 8 200000 400000 6 NO 492 U 16 30 2012 F 6 PED Resuscitation warmer 2 6000 12000 DERMATOLOGY GROUP 1 Tender opening dates GROUP 1 Date of opening Technical bids 05 09 2012 Date of demonstration of equipment by tenderers qualifying in Technical bids 06 09 2012 Date of opening of Financial tenders of tenderers qualifying through technical bids amp demonstration 07 09 2012 GROUP 2 Date of opening Technical bids 10 09 2012 Date of demonstration of equipment by tenderers qualifying in Technical bids 11 09 2012 Date of opening of Financial tenders of tenderers qualifying through technical bids amp demonstration 12 09 2012 GROUP 3 Date of opening Technical bids 13 09 2
7. I 1 CAS ee 12 120000 240000 monitor NO 492 U 16 30 2012 K 1 MED Nebulizer 15 1500 7500 O GRoP 3 O ANAESTHESIOLOGY 1 NO 492 U 16 30 2012 M 1 ANAS Nerve Stimulator 1 7500 15000 E T S cu NO 492 U 16 30 2012 N 1 ICU Defibrillator 8 120000 240000 NO 492 U 16 30 2012 N 2 ICU Syringe pump 8 24000 48000 NO 492 U 16 30 2012 N 3 ICU Blood Gas Analyser 1 50000 100000 NO 492 U 16 30 2012 N 4 ICU Fluid Warmers 4 18000 36000 GROUP 4 OCCUPATIONAL THERAPY 1 NO 492 U 16 30 2012 D 1 OCC TH Dual channel E M G 1 2500 5000 2 NO 492 U 16 30 2012 D 2 OCC TH Finger Dextrity Testy 1 1000 2000 3 NO 492 U 16 30 2012 D 3 OCC TH cerebral palsy chair 1 750 1500 4 NO 492 U 16 30 2012 D 4 OCC TH Hand Dynamometer 1 1000 2000 5 NO 492 U 16 30 2012 D 5 OCC TH a ne 1 2500 5000 Hand Tapper test board 6 NO 492 U 16 30 2012 D 6 OCC TH lt n 1set 750 1500 7 NO 492 U 16 30 2012 D 7 OCC TH Hand Tool Test Frame 1 750 1500 P E G Board Test PURDUE 8 No 492 u 16 30 2012 0 8 OCC TH pE BOARD 1 1500 3000 Sensory Integration and 9 NO 492 U 16 30 2012 D 9 OCC TH Poris test SIPT 1 2500 5000 10 NO 492 U 16 30 2012 D 10 OCC TH Activity Mattress 1 750 1500 11 NO 492 U 16 30 2012 D 11 OCC TH Ankle Excerciser 1 750 1500 Continous passive motion 12 NO 492 U 16 30 2012 D 12 OCC TH oper EXTREMITY
8. make free replacement if required in lieu of damaged lost items etc irrespective of any settlement by the insurers bb The tenderer s liability shall be restricted to making free replacement rectification and any local expenses such as custom duty Octroi clearance etc connected with such replacements shall be borne by the hospital cc If in consideration or offer of earlier delivery the contract is placed with higher tenderer on preference to the lowest offer the tenderer will be liable to pay to the hospital the difference between the contract rate and that of the lowest acceptable tenders on the basis of the final price CIF destination including all elements of freight sales tax local taxes duties and other incidentals in case of failure to complete supplies in terms of such contract within the date of delivery specified and incorporated in the contract This is in addition to compensating the hospital on all other losses and damages resulting from delayed supplies and cancellation and risk purchase in case of failure to supply the equipment dd GUARANTEE WARRANTY The tenderer will be required to furnish guarantee warranty from the manufacturers as under against defects of manufacture workmanship and poor quality components for the entire equipment shall be for a period of 24 months with spares and 36 months without spares starting from the date of satisfactory installation commissioning and handing over of the equip
9. stainless steel Outside mild steel only powder coated to 2 1 2 filled by glass wood insulation Temperature ranges from 50 degree C to 150 degree C Temperature controlled by Hydraulic types Thermostat Knobs of which is graduated 50 degree C to 250 degree C Unit working on 220 V AC and control Panel have on off Temperature display by mercury manometer on dial type thermometer and above digital display Switch high low switches indicator lamp and thermostat Heating elements in 3 sides Digital temperature controller and air circulation fan Instrument should not be refurbished After sale service should be best in the industry with service Engineer Applications Specialist based in Bangalore AMC to be provided and calibration to be given every year CENTRIFUGE NO 492 U 16 30 2012 A 6 LAB 24 Bucket capacity Stepless spud regulator Safety lid interlock to prevent cover opening during centrifugation Digital speedometer 0 60 digital countdown timing Brushlem induction motor with frequency device Stable speed out put even under unstable Voltage condition 7 segment LED Display of speed Digital Countdown times Dynamic brake for quick acceleration Imbalance and Inverters fault detection with Auto shutdown Selection of 3 acceleration and deceleration profiles Recall of last set parameter Useful for repetitive analysis Alpha Numeric LCD display of speed Automatic door opening through gas hinges T
10. submission and opening of the tender being a holiday for hospital then due date for submission of completed tenders opening of the tender will be the immediately following working day at the same hour c Application amp the tender document can also be downloaded from our web site www esickar gov in amp Www eprocure gov in In case of applications amp documents downloaded from the web site the same shall be submitted alongwith the application fees failing which the application is liable for rejection and no further communication shall be entertained in the matter TERMS amp CONDITIONS a b c d e g h 1 k During the service contract period the firm shall provide preventive maintenance and in addition attend to all emergent and breakdown calls During the currency of the Warranty Guarantee period all parts replacements components covered therein shall be replaced free of cost including labour During the CMC AMC service period charges costs as per the agreed terms based on the bids submitted shall be paid by the hospital However the firm should complete all formalities of procuring importing the parts replacements components etc the cost of which shall be borne by the hospital on submission of authenticated documentary evidence for all the expenses incurred thereon after the satisfactory service duly certified by the user department The bidders are required to submit a certificat
11. 012 Date of demonstration of equipment by tenderers qualifying in Technical bids 14 09 2012 Date of opening of Financial tenders of tenderers qualifying through technical bids amp demonstration 15 09 2012 1 NO 492 U 16 30 2012 H 1 DERMA Liduid nitrogen cryojet 1 2500 5000 machine Graft spreader and 2 NO 492 U 16 30 2012 H 2 DERMA Aaaa d ubleend 1 2500 5000 High frequency radio surgery 3 NO 492 U 16 30 2012 H 3 DERMA unit electro diathermy 1 1250 2500 machine 4 NO 492 U 16 30 2012 H 4 DERMA Dark field microscope 1 10000 20000 5 NO 492 U 16 30 2012 H 5 DERMA Nail extractor amp dissector 1 1000 2000 6 NO 492 U 16 30 2012 H 6 DERMA Tattoo pencil set 1 1500 3000 a a en E N T Operating Microscope 1 NO 492 U 16 30 2012 C 1 ENT with Zoom and 5 step 1 25000 50000 magnification changer Clinical Diagnostic Pure tone 2 NO 492 U 16 30 2012 C 2 ENT Audionietry 1 10000 20000 croup 2 OO OPHTHALMOLOGY NO 492 U 16 30 2012 L 1 OPTH Goldmannaplanati n 1 4250 8500 tonometer NO 492 U 16 30 2012 L 2 OPTH A Scan 1 6250 12500 NO 492 U 16 30 2012 L 3 OPTH Automated Perimeter 1 45000 90000 NO 492 U 16 30 2012 L 4 OPTH Indirect Ophthalmoscopy 1 4000 8000 NO 492 U 16 30 2012 L 5 OPTH ee Lensomieter with 1 11250 22500 Operating Microscope NO 492 U 16 30 2012 L 6 OPTH 1 60000 120000 U 16 30 THUS Ophthalmology Multi ter bedsid NO 492 U 16 30 2012
12. 0cm Focus adjustable by sterilizable handle L E D Life time 50 000 hours Light rotation 360 Degree No of light modules 6 Emergency Battery backup 4hrs at least 6 I SO CERTIFIED OT TABLE for MINOROT No 492 U 16 19 2012 B 2 SURGERY SPECIFICATION e Should be mobile modular operating table for any surgery electro hydraulic drive with corded hand control with upper back plate with leg plates with head rest with SFC padding of 80 mm Electro mechanical adjustments Height 760mm to 960 mm Trendlenberg reverse trendlenberg 25 25 degree Lateral tilt 15 degree Manual adjustments a standard back plate 90 45 b standard head rest 45 45 back rest with gas spring up down 65 75 head rest detachable leg rest detachable standard four section mattress one set Accessories a arm board two b anaesthesia screen one c body strap one d radial setting clamp three e goepel knee crutches two f perineal cut out filter one e Base braking lock unlocking e Shall meet IEC 60601 1 2 2001 or equivalent safety e General requirement of safety for electro magnetic compatibility or should comply with 89 366 EEC E M C directive e Manufacturer should have ISO certification Should be FDA CE UL or BIS approved F PEDIATRICS NO 492 U 16 30 2012 F 1 PED ELECTRONIC DIGITAL WEIGHING SCALES i Neonate e Electronic digital scale with a large pan with stable base
13. 1 2000 4000 13 NO 492 U 16 30 2012 D 13 OCC TH Ergometer MX 1 1 2000 4000 14 NO 492 U 16 30 2012 D 14 OCC TH Medicinal Balls 1 5kgs leach 2500 5000 Nirmal Table For Hand 15 NO 492 U 16 30 2012 D 15 OCC TH pte 1 1000 2000 16 NO 492 U 16 30 2012 D 16 OCC TH Peddo Cycle 1 1500 3000 Sanding unit overhead with 17 NO 492 U 16 30 2012 D 17 OCC TH a a abn 1 750 1500 Sanding unit vertical wall 18 NO 492 U 16 30 2012 D 18 OCC TH 1 750 1500 mounting Sanding unit with adjustable 19 NO 492 U 16 30 2012 D 19 OCC TH incline for reciprocal 1 750 1500 exerciser Tilt table Electrically 20 NO 492 U 16 30 2012 D 20 OCC TH 1 1250 2500 u 16 30 2012 0 20 Pias 21 No 492 U 16 30 2012 D 21 occ tH Vestibule proprioceptive 1set 1500 3000 equipments a Swing 22 NO 492 U 16 30 2012 D 22 OCC TH Ramp with Curbs 1 1000 2000 23 NO 492 U 16 30 2012 D 23 OCC TH Bubble ball bath with Balls 1 1000 2000 24 NO 492 U 16 30 2012 D 24 OCC TH JUMP 200 Trampoline 1 750 1500 Th last sheets 10 25 NO 492 U 16 30 2012 D 25 OCC TH a ast sheets 10 3000 6000 26 NO 492 U 16 30 2012 D 26 OCC TH Splint thermal bath 1 1000 2000 27 NO 492 U 16 30 2012 D 27 OCC TH Fa Ethaflex 10 10 750 1500 28 NO 492 U 16 30 2012 D 28 OCC TH Wheel chair adjustable 1 1250 2500 NO 492 U 16 30 2012 D 29 OCC TH Multiactivity workstation 1 2500 5000 PHYSIOTHERAPY NO 492 U 16 30 2012 E 1 PHY Hand e
14. 30 2012 K 1 MED NEBULIZER e Compact and heavy duty for hospital use e Must be able to run continuously for hour uninterrupted e Must be easily portable e Must be compressor type e Electrical requirements 220 240 VAC 50 Hz e Sound level not less than 60 db e Air flow 9 Ipm e Nebulization rate 0 15ml min e Nebulizer aerosol size 5 microns e Compressor pressure 2 to 2 5 bar e Operating temperature 5 to 40 degree c e Operating humidity upto 95 e Nebulizer capacity 6 ml e Mode of operation continuous e Should comply with I EC 60601 1 2 or BIS equivalent e Should work with Indian plug pin e Should be supplied with English instruction guide Warranty period must be 5 years M ANAESTHESIOLOGY NERVE STIMULATOR NO 492 U 16 31 2012 M 1 ANAS Standby A Standby switch maintains power to the instrument without generating stimulus pulses Twitch 1 s 1 pulses S 2 Hz 2 pulses S 10s 1 pulse 10s Tetanus 50 Hz 50 pulses S 100 Hz 100 pulses s Stimulus Pulse Square Wave Monophasic pulses 200 U S Duration Stimulus Pulse 22 milliseconds square wave monophasic Pulse Width 30 millisec Current 0 35 millisec Indicators Battery LED indicater Power Source 9 V alkaline battery access door on rear panel Power Consumption Approximately 15 5 Ma Power Source One 9 Volt battery Voltage 0 450 volts open circuit Output Voltage 450V 10 Output Adjustable with rotating potentionme
15. AMC service contract period the time taken by the hospital in providing to the firm the spare parts shall not count towards the downtime During the guarantee period the time taken by the hospital to provide the custom s duty exemption certificate Not Manufactured in India certificate Import License etc for enabling the tenderer to import any spare part shall not count towards the downtime uu TIME OF OPENING OF TENDER The process of opening the technical and financial bids and the times thereon are as stipulated elsewhere in this document The tenderer is at liberty to be present in person or through their authorized representative at the opening of the tender In the event of the day of receipt and opening of the tender being a holiday for hospital then due date for receipt of completed tenders opening of the tender will be the immediately following working day at the same hour vv VALIDITY OF TENDERS The tenderers shall make their offers valid for acceptance for a period of 180 days from the date of opening of the bids ww PAYMENT The hospital will pay 90 of the CIF value excluding the Agency Commission of the equipments to the tenderer through an irrevocable Letter of Credit LOC against negotiable shipping documents or cheque drawn in favour of the tenderer as the case may be The balance 10 of the payment will be made after 3 months of satisfactory performance of the equipment xx In case of imported equipment the country of ori
16. C TH Hands On Hand Evaluation Set should include JAMAR Hydraulic Hand Dynamometer B amp L Pinch Gauge 0 60 Ibs 0 27 kg Small Joint Goniometer 6 E Z Read Goniometer Flexible Tape Measure Finger Circumference Gauge centimeters Semmes Weinstein Monofilaments Set of Five 2 83 3 61 4 31 4 56 6 65 DISCRIM A GON HAND TAPPER TEST BOARD ELECTRIC NO 492 U 16 30 2012 D 6 OCC TH e Should be in wooden material laminated amp durable e Should have digital counter amp timer to record the progress e Heavy duty for hospital use e Should be supplied with English instruction guide HAND TOOL TEST FRAME NO 492 U 16 30 2012 D 7 OCC TH The test should consist of tools amp two uprights with bolts Container Drawer should be provide to store tools Test should measure proficiency in using ordinary mechanics tools Should be in wooden material should be laminated Should be durable amp portable PEG BOARD TEST PURDUE PEG BOARD NO 492 U 16 30 2012 D 8 OCC TH Measures gross movement of hands fingers and arms and finger dexterity Should Include Manual with instructions Normative data Record blanks A stopwatch Pins Washers and Collars Laminated amp durable Pegboard SENSORY INTEGRATION AND PRAXIS TEST SIPT NO 492 U 16 30 2012 D 9 OCC TH Composed of the following 17 brief tests Space Visualization Figure Ground Perception Standing Walking Balance Design Copying Postural Prax
17. Capacity Upto 10 kg witha provision for measuring height Upto 50 cm on the side 6 Accuracy 1 gm Large LCD display for reading Easy to Clean e Note for all scale weighing caliberation check should be done once half yearly at least ii Infant and Child Capacity Upto 120 kg Resolution 10 gm Accuracy lto 10 gm Measuring position supine sitting and standing Large LCD Display Note for all scale weighing caliberation check should be done once half yearly at least OPTHALMOSCOPE NO 492 U 16 30 2012 F 2 PED Big handle with 2 big size cells with box case CUTANEOUS BILIRUBINOMETER NO 492 U 16 30 2012 F 3 PED Measuring range 0 0 mg dl to 20mg dl Standard error or 1 mg dl based on clinical data hand held light weight Should have internal rechargeable battery lasting upto 500 measurements charge preferably nil consumables easy to ready display mg dl u mol L Should confirm to IEC CE standards DOUBLE SURFACE CFL PHOTOTHERAPY UNIT NO 492 U 16 30 2012 F 4 PED Unit should have CFL Lamp source in both upper and lower sides a Upper surface Microprocessor controlled with up down side tilt facility and height adjustable 6 CFL unit 4 blue light amp 2 white light Should have an irradiance level of more than 18u w em2 nm Chronometer to measure lamp usage Should have a wide base for rigidity Should have internal and external reflectors to avoid wastage of light rays by sending u
18. ITH PRINTER NO 492 U 16 30 2012 L 5 OPTHAL Measurement range Sphere Spectacle lenses 0 to 25 D 0 10 0 12 0 25D steps Contact lenses 0 to 25 D 0 01 0 06 0 12 0 25D increment Cylinder 0 to 10 D 0 10 0 12 0 25D steps Axis 1 to 180 1 step Prism 0 to 20A 0 01 0 12 0 25A steps Addition 0 to 10 D 0 10 0 12 0 25D steps Cylinder mode Mix Prism mode X Y Orthogonal coordinates P B Polarcoordinates Lens detection Wavelength criterion Lens Diameter Screen Data display PD Measurement range on PD model only External interface Power supply Dimensions Weight Drop in fast printer Standard accessories Optional accessories No display Single Progressive Auto e lined d line with ABBE compensation 5 to 100 mm 5 7 inch 320x240 dots colour S C A P Add R L Bar meter distance Rx add power 50 90 mm RS232Cx2 USB 2 0 x1 100 240V 50 VA Auto shut off in 10 minutes 194 W x 220 D x408 H mm Approx 4kg Thermal printer with auto cutter Power cord Dust cover Nosepiece for contact lenses Printer paper Measuring progressive power lenses explanation sheet Eye care card RS 232C communication cable USB Cable with special USB driver foot switch OPERATING MICROSCOPE OPTHALMOLOGY NO 492 U 16 30 2012 L 6 OPTHAL Magnification changer Focusing Objective Eyepieces illumination APO chromatic 5 step changer motorized Motorized 40mm adjustable spe
19. NCE CORPORATION HOSPITAL Under Ministry of Labour amp Employment Govt of India Sy No 11 55 1 Plot No 1 5 Main FTI Campus Yeshwanthpur Industrial Suburb Bengaluru 560 022 Ghia Se NM Telefax No 080 23579467 e mail esichpeenya gmail com No 492 U 16 30 2012 Central Stores Dated 31 07 2012 To Application Cost Rs1000 Non refundable Dear Sir Sub Your requisition for issue of tender documents for supply installation commissioning amp maintenance of Medical Equipment of various departments Reg Ref 1 Our advertised tender enquiry of even no dated 0 2 Your request letter bearing NO 2 1cccececensesereees dated With reference to above please find enclosed a set of tender documents alongwith all annexures Yours faithfully Stores Manager Received A set of tender documents with all enclosures Name Seal amp Signature of the tenderer ANNEXURE 5 EMPLOYEES STATE INSURANCE CORPORATION HOSPITAL Under Ministry of Labour amp Employment Govt of India Sy No 11 55 1 Plot No 1 5 Main FTI Campus Yeshwanthpur Industrial Suburb Bengaluru 560 022 Ghia Se Mt Telefax No 080 23579467 e mail esichpeenya gmail com No 492 U 16 30 2012 Central Stores Dated 31 07 2012 TECHNICAL SPECIFICATIONS OF MEDICAL EQUIPMENT LABORATORY No 492 U 16 30 2012 A 1 LAB DIGITAL INCUBATOR N Temperature ranges from 5 degre
20. NIENCE The purchaser may by written notice sent to the tenderer terminate the contract in whole or in part at any time for his convenience The notice of termination shall specify that termination is for the hospital s convenience in public interest However the equipment that are ready for shipment within 30 days after the tenderer s receipt of notice of termination shall be purchased by the hospital at the contract terms and prices For remaining equipment the hospital may choose to have any portion completed and delivered at the contract terms and prices and or to cancel the remainder of the supply order Jjjj GOVERNMENT LANGUAGE The contract shall be written in the language of the Bid English Language as specified by the hospital All correspondence and other documents pertaining to the contract shall be in English or Hindi or Kannada Medical Superintendent ANNEXURE 2 DETAILS OF THE TENDERER SIN Particulars TO BE FILLED BY THE TENDERER Name of the Firm Supplier Postal Address with Telephone No Fax No Mobile No E Mail Address Annual Turnover for the last three years a 2008 2009 b 2009 2010 c 2010 2011 CST KST VAT PAN No a Factory License No b Shops amp Estt License No c Municipal Local authority License No copy to be enclosed Details of EMD a DD Bankers Cheque 6 No b Name of the Bank c Branch d Amount Wheth
21. all apply The tenderer shall if called upon to do so replace within a period of fourteen days or such time as may be stipulated by the hospital at their discretion the goods stores articles or such portion there of as rejected by the hospital and in such an event the above mentioned warranty period shall apply to the goods stores articles replaced from the date of the replacement there of otherwise the tenderer shall pay to the hospital such damage as may arise by reason of breach of the conditions here in contained Nothing herein contained shall prejudice any other right of the hospital in this regard MODE OF DESPATCH DELIVERY AND COMMISSIONING OF EQUIPEMENT The equipment with all its accessories should be dispatched duly insured freight insurance and all incidental charges prepaid The tenderer is required to undertake to deliver install and commission the equipment within a period of 15 days or as expressly stipulated in the supply order mm DELAY IN SUPPLIES INSTALLATION LIQUIDATED DAMAGE In the event of delays in supply installation and commissioning of the equipment to the satisfaction of the hospital beyond the stipulated date time the hospital shall have full rights to recover damages at the rate of 1 of the CIF value of the equipment including components spares accessories and optional items per each day of delay or part there of till the actual supply installation amp commissioning of the equipment to th
22. at their discretion the goods stores articles or such portion there of as rejected by the hospital and in such an event the above mentioned warranty guarantee period shall apply to the goods stores articles replaced from the date of the replacement there of failing which I we shall pay to the hospital such damage as may arise by reason of breach of the conditions here in contained Nothing herein contained shall prejudice any other right of the hospital in this regard Name Signature Designation Stamp of the tenderer AuthorisedSignatory ANNEXURE 4 TO BE FILLED IN BY TENDERER AND RETURNED WITH THE TENDER To The Medical Superintendent ESIC Hospital Sy No 11 55 1 Plot No 1 5 Main Road FTI Campus Yeshwanthapur Industrial Sub urb BANGALORE 560 022 Dear Sir Sub Your advertised tender enquiry NO see cases ended de cece es ce cree hese tease eck dated vasosecicscdsvccsvacvesas for medical equipment Reg We submit herewith our quote against your advertised tender enquiry bearing RG a aaee a E A A S ated ratirecieeundeevtats for linen items We have carefully perused the Terms and Conditions as stipulated therein and accept the same unconditionally Firm s Name amp Address Signature of Authorised Signatory WITNESS Signed in my presence Name Designation Seal Notary Public Gazetted Officer with name amp Complete Address Place Date EMPLOYEES STATE INSURA
23. atic and manual tests Print and store test automatically Internal memory stores up to 250 tests amp above Test head set TDH39P bone vibrator subject response hand switch free field speaker Accessories Very good quality table with drawer to keep audiometer amp accessories Revolving chair with back rest for audiologist Desktop Computer Intel dual core 3 2GHz intel mother board 9 75x LCD monitor 17 HDD 320 SATA RAM 4GB ATX cabinet DVD rewriter mouse multimedia keyboard 2 1 speaker card reader mike antivirus windows 7 OS with compatible software Laser printer cum copier Large print out results color printer Fast print less than 20 seconds UPS L OPTHALMOLOGY NO 492 U 16 31 2012 L 1 OPTHAL GOLDMANN APPLANATION TONOMETER It should be Original Goldmann standard in IOP measurement Must have Best reproducibility and accuracy Should be having Measuring range from 0 80mmHg Measurement Divergence of the force impingement on the measuring prism over a measuring range from 0 58 84Mn Reverse Span lt _0 49mN Net Weight should be 0 500kg or less Should be compatible with Haag Streit Type Slit Lamps Reliable and durable Reusable Tonometers Prism should be supplied along with one extra prism TECHNICAL SPECIFICATION OF A SCAN BIOMETER NO 492 U 16 30 2012 L 2 OPTHAL Transducer Probe e IOL power Calculation formulas Frequency e 10mhz e SRKT Haigis 10 Fixation e Internal e SRK II Hoff
24. chanical shocks amp vibrations salt and precipitation during transit and open storage etc The Packing case size and weights shall duly take into consideration the remoteness of the equipment s final destination and absence of heavy handling facilities at all points in transit The packing marking shall show the description of the equipment s quantity contents the name of the consignee and address the gross weight a distinctive number of mark sufficient for the purpose of identification Besides each package shall contain the number and date of order nomenclature of the goods Schedule of parts for each complete equipment giving part number with reference to assembly a packing note quoting the name of the purchaser aaa Not withstanding anything stated in the relevant clauses the tenderer shall be entirely responsible for any loss damage deterioration depreciation of the goods due to faulty packing bbb ARBITRATION If at any time any question dispute or difference whatsoever shall arise between the two parties hospital on the one hand and tenderer on the other hand in relation to the purchase either of the parties may give to the other a notice in writing of the existence of such a question dispute or difference and the same shall be referred to two arbitrators one to be nominated by the hospital and the other to be nominated by the tenderer Such a notice of the existence of any question dispute or difference in connecti
25. e C ambient to 80 degree C N Outside to be made up of mild steel duly powder coated 2 5 thick glass wool insulation N Double walled inside to be made up to stainless steel N Digital temperature control with an accuracy of 1 degree C N Should include all circulating fan N Perforated Adjustable shelves N Digital Display of temperature s Heating Element to be placed is ribs that the bottom and sides 13 size mating element N To work with 230 V AC with on off switch cord and plug N Size 450X450X450 mm of chamber 2 95 L N Warranty for 2 Years Original Instrument not refurbished N AMC to be provided and calibration to be given every year N After sale service should be best in the industry with service Engineer Applications Specialist based in Bangalore TRINOCULAR MICROSCOPE No 492 U 16 30 2012 A 2 LAB Universal Infinity Corrected Optical System Wide Field 10 X Plan eye pieces with Acromatic Objectives 2X 5X 10X 40X and100X Built in transmitted Kochler illuminater LED type white light illumination X Y Stage with double slide holder Focus control with course and fine focus facility Scratch Resistance Stage Trinocular 30 35 degree viewing angle with inter pupillary adjustment Should be upgradable with facility for florescents polorizer phase contrast dark field condenser Digital Camera Attachment up to 10 Mega pixel live resolution CCD Sensor Size of 8 1 X 6 64 mm Universal Condenser Warranty for 2 years
26. e as stipulated by the competent authority based on the requirements of demonstrations and other related issues However the dates of demonstrations remain the same as mentioned elsewhere in this document pp SIGNING OF CONTRACT The successful bidder will be required to enter into an agreement with the hospital on a non judicial stamped paper for the supply and satisfactory installation and commissioning of the equipment as per specifications and terms and conditions listed in this tender document and agreed upon The tenderer shall bear the cost of agreement and registration as required qq TRAINING The tenderer shall after the satisfactory installation and commissioning of the equipment adequate training to the staff of the hospital at site at no extra cost rr OPERATING MANUALS The tenderer shall provide the complete operating manuals in English or Hindi or Kannada languages for the equipment supplied by them Atleast English is a must ss Warranty Guarantee The tenderer shall provide duly signed dated stamped and authenticated Warrranty Guarantee cards documents which shall come into effect from the date of successful commissioning of the equipment to the satisfaction of the hospital tt UPTIME GUARANTEE At the end of the warranty guarantee period the hospital shall enter into a CMC AMC service contract with the tenderer The tenderer shall ensure during and after the warranty guarantee CMC or AMC service contract that the e
27. e satisfaction of the hospital subject to a maximum of 10 of the CIF value beyond which the supply order shall stand automatically cancelled the EMD forfeited amp the Bank Guarantee is liable to be invoked nn OPENING OF BIDS The Technical bids shall be opened first on the dates stipulated elsewhere in this document The tenderers are also required to give a demonstration of their equipment vis a vis the specifications offered before the Technical Evaluation Committee TEC The space electric power amp such normal facilities that are available with the hospital will be provided for the technical demonstration However all the required materials and other paraphernalia required for the demonstration shall be carried by the tenderers themselves The decision of the TEC is final and binding on the tenderer with regard to the acceptance of the technical bids and final technical evaluation through demonstrations and no communication in this regard will be entertained The Financial bids of only those tenderers whose technical bids have been accepted and have also qualified in the demonstrations will be opened on the dates times mentioned elsewhere in this document 00 TIME amp PLACE OF OPENING BIDS All bids whether technical or financial shall be opened in the Conference Hall of the hospital at 1100 Hrs on the dates stipulated elsewhere in this document The time of demonstration of the equipment shall be at 1000 Hrs at the plac
28. e that they have satisfactory service arrangements and fully trained service staff to support the uptime guarantees Details of the service centres alongwith the postal addresses amp contact persons amp telephone numbers should also be enclosed to the technical bid Tenders not containing service contract details amp charges are liable to be rejected The bidders are required to undertake the repair replacement service maintenance of the equipment supplied by them through CMC AMC till the operating life of the equipment The bidders cannot opt out of the CMC AMC service contract except under the condition that their entity has become insolvent or liquidated or stops their operations completely Bidders must attach along with the Technical Bid a photocopy of the relevant document showing the constitution of the entity with the details of all the stake holders of the entity Foreign firms bidding directly should attach along with the technical bid a certificate giving the name and address of their Indian agents or their representatives in position in India for servicing the equipment In case the bid is from other than manufacturers then a certificate that the quantum of Commission charged by them is the same or lesser than that being charged to other departments Institutions for similar same items must accompany the Technical Bid A list detailing all places in India where the same similar equipment has been provided installed by t
29. ed f 200mm OPTIONS 175mm 225mm or WD 175mm 200mm APO 10x 21 B wide field eyepieces for eye glasses wearers Diopter adjustment 5 with adjustable eyecup Halogen Homogenous coaxial integrated Red Reflex illumination Sterile adjustment of light intensity by surgeon Long lasting illumination free of UV and IR 2 free openings for selectable filters dia 32mm Inclining mechanism 15 manual fine adjustment Adjustable speed for drives Foot switch XY unit Stand Type Base Base dimension Maximum load Maximum reach Minimum ight Weight approx Accessories Assistant s attachment Beam splitter TV photo Asepsis Electrical data Supply Protection class 8 Function foot switch waterproof upgradeable X Y unit Positioning range 40 x 40mm with reset adjustable speed Compact floor stand Compact foot with 4 movable rollers 4 foot brakes 608 x 608mm 3 5kg accessories on the microscope 1068mm 1680mm 100 kg minimum equipment Stereo co viewer Monocular co viewer 50 50 or 70 30 2D video system Zoom Video Adapter f 35 100mm Photo TV dual attachment f 60 85 107mm for TV f 250 350mm for 35 mm camera TV attachment f 107mm Photo attachment f 250 350mm Sterilisable components for all controls 100 240 VAC 10 50 60 Hz 100 VA Class I IL CASUALITY NO 492 U 16 30 2012 1 1 Casualty MULTIPARA METER BEDSIDE MONITOR e Should have TFT LCD display 10 4 to 12 with wave for
30. er Assessed under IT 7 Act If so enclose IT returns for the last three years Names amp addresses of other 8 hospitals etc to whom linen is supplied 9 Whether service is provided for 24 hours and on all days 10 Any other information relevant to the subject Declaration I We hereby declare that the information as provided above is correct amp true to the best of my knowledge Place Name Signature amp Seal of the tenderer Date Annexure 3 UNDERTAKING I We the undersigned tenderers duly authorized signatory ies Shri Smt of M s hereby undertake that the goods stores articles supplied to the hospital under this contract shall be of the best quality and workmanship and shall be strictly in accordance with the specifications and particulars contained mentioned in the clause here of and I We hereby guarantee that the said goods stores articles conform to the description and quality aforesaid The hospital will be entitled to reject the said goods stores articles or such portion there of as may be discovered not to conform to the said description and quality And on such eventuality the goods stores articles will be at my our own risk amp responsibility and all the provisions here in contained relating to rejection of goods etc shall apply I we shall if called upon to do so replace within a period of fourteen days or such time as may be stipulated by the hospital
31. er Q LED Sampling e 15 625 e Holladay Binkhorst I Frequency MHz 10 e Bandwidth e gt 6mhz at e Print Out 6db e Accuracy e Through External Thermal Printer Optional e Electronic e 0 02mm e Power e Sound Velocity phakic status e Voltage e 100 240VAC functions e Anterior e 1533m s e Frequency e 50 60Hz Chamber e Normal lens s 1641m s e Consumption e 26VAC e Vitreous e 1532m s e Size e Aphakic e 1532m s e Height e 12 cm 5 e Cataract 1629 m s e Width e 30cm 12 e IOL e Depth e 28 cm 11 e PMMA e 2718m s e Weight e 2 6 Kgs e Silicone e 1486m s e Standard Accessories e Acrylic e 2200m s e Solid tip transducer with fixation light e Measurement modes e User Manual e Automatic e 2 spare fuses e Continuous e e RS 232 Port e Manual e e e Calibration s e Software Memory N e Scan Memory is 10 per eye with 6 Standard Deviation of Axial Length amp Anterior e Chamber Depth e e User Memory e e Surgeon e 6 Profiles e OL styles e 10 surgeon e e Patient e lt 100 N Memory e Analysis e 10 AUTOMATED PERIMETRY NO 492 U 16 30 2012 L 3 OPTHAL Peripheral Range 90 Static Perimetry DS NS Fixation Control amp Pupil Measure Head position recognition Ethernet connection Stimulus Sizes 111 V Stimulus Sizes 1 V Expert Opinion Easterman test Kinetic Disability test Automated Lens Holder Lens Distance Control EyeSuite Perimetry Lite Standard white w
32. ge tank Liquid nitrogen 196 degree c supply from local vendors Regular maintenance GRAFT SPREADER AND DISSECTOR DOUBLE ENDED NO 492 U 16 30 2012 H 2 DERMA Double ended HIGH FREQUENCY RADIO SURGERY UNIT ELECTRO DIATHERMY MACHINE NO 492 U 16 30 2012 H 3 DERMA Power required 230V 50Hz Dimensions mm 260 x 300 x 150 weight 7 Kg Electrodes Insulated Frequency 20 2 93 u Hz Cut 70 Cut 30 Loag Loag 60 Loag 40 Cut Fulgration should be availabe Intensity Control linear Standard accessories Monopolar handle 1 patient plate 1 Electrodes set 1 extra set for replacement to be given complimentary Foot Switch 1 Carrying Case 1 Hand Switch 1 Bipolar cable and forceps 1 no each e Maintenance to be done once year DARK FIELD MICROSCOPE NO 492 U 16 30 2012 H 4 DERMA e Binocular microscope e Dry dark field condenser e 30 inclined 360 swiveling compensation free binocular head e 3 D mechanical stage e Intensity variable halogen illumination system e 40X 2000X NAIL EXTRACTOR AND DISSECTOR NO 492 U 16 30 2012 H 5 DERMA e 14cm long e Concave blades ELECTRICAL TATTOO PENCIL MACHINE SET NO 492 U 16 30 2012 H 6 DERMA e Very light weight e Single double pin needle arrangement e Battery backup facility e Hand switch control e Both press and do auto switch available e Pigments set C E N T E N T Operating Microscope with Zoom and 5
33. gin will be only one Any single equipment having more than one country of origin will not be accepted by the hospital The cost of release of LOC by the foreign firm will be borne by the tenderers No amendment in LOC will be allowed in deviation from the conditions contained in the original tender yy PAYMENT OF COMMISSION TO INDIAN AGENCIES FOR IMPORTED EQUIPMENTS The hospital shall make all reasonable and due efforts to pay the Indian Agency Commission at the earliest possible date after 3 months of satisfactory installation commissioning amp handing over of the equipment in good working condition besides training of the staff in operating the equipment The rate of exchange applicable for converting agency commission into equivalent Indian Rupees shall be the T T selling rate prevalent on the date of releasing the documents by the Bankers The Indian Agency Commission will be paid in Indian Currency Rupees to the Indian Agents zz PACKING amp MARKING Best in trade packing practices suitable for safe Rail Road Air transit shall be used subject to packing and marking being acceptable to the Inspecting Authority The tenderer shall provide such packing of the goods as is required to prevent their damage or deterioration during transit to their final destination as indicated in the contract The packing shall be sufficient to withstand without limitation rough handling during transit and exposure to extreme temperature humidity me
34. he Maximum rpm is 6000 rpm Capacity maximum 400 ml Max and 5070 g Warranty 2 years Instrument should not be refurbished After sales service should be the best in Industry with service Engineer Application specialist based in Bangalore AMC should be available calibration certificates to be given every 6 months CMC for 5 years NO 492 U 16 30 2012 A 7 LAB Semiautomated coagulation analyser Should be able to perform PT APTT TT fibrinogen assay clot based assay D dimer Measuring system must be optomechanical Measuring channels dual channels Mixing with magnetic stirrer motor Tungsten light source Two incubation block incubation block temperature controlled at 37degree 1 degree Reagent position 4 cuvette position 12 Back illuminate liquid crystal display LCD Should have built in thermal printer Should be able to detect even the smallest fibrin clot Should provide certainty and uniformity in the INR values After sales service should be the best in industry with service engineer application specialist based in Bangalore AMC should be available calibration certificate to be given every 6 months To be supplied with UPS CMC for 5 years Demo kit reagents to be provided PM kit every 6 months as per instrument requirement B GENERAL SURGERY L E D Mobile Operation theater Light No 492 U 16 19 2012 B0 SURGERY Illumination intensity at 1m 1 Lakh Field size of 1m distance 20cm 25cm Working distance 12
35. he bidder should be attached Documentary evidence wherever possible in support of this list and also certificates of its satisfactory working from those mentioned in the list should be enclosed In case the offer is from other than manufacturers then a letter of authority from the manufacturers authorizing the firm to tender on their behalf must accompany the technical bid failing which the bid is liable to be rejected Bidders must furnish along with the technical bid the latest current valid Income Tax clearance Certificate and Sales Tax Certificate or attested photocopies there of Bidders must furnish along with their technical bid a certificate that the Agency Commission if any payable has been included and that no Agency Commission U other than that included in the bid price is payable by the manufacturers to the Agency The tender must be accompanied with the stipulated Earnest Money as detailed elsewhere in this document m Bids not accompanied by Earnest money as stated above or less are liable to be n 0 p q s t v w x y rejected Earnest money security deposit any other sums of the tenderers with the hospital in connection with any other tender case will not be considered against this tender The successful bidder shall be required to furnish a contract Performance Guarantee by way of a Bank Guarantee issued by a nationalised bank for an amount as stipulated elsewhere in t
36. heir behalf Certificate to the effect that the bidder is the manufacturer of the equipment authorised sole distributors or sole agents for manufacturer on whose behalf they are quoting must be included in the documents The said certificate should be duly attested amp stamped by the authorized signatory of the manufacturer sole authorised distributor or sole agent as the case may be The firm should enclose a certificate that they are enrolled with the Directorate General of Supplies amp stamped by the authorized signatory of the firm The firm should enclose a certificate that they are enrolled with the Directorate General of Supplies amp Disposals Parliament Street New Delhi to act as Indian Agent IMPORTANT DATES FOR ISSUE amp SUBMISSION OF TENDER DOCUMENTS a Tender documents can be obtained from the Central Stores of the Office of the Medical Superintendent from 6 08 2012 to 27 08 2012 between 1000 Hrs amp 1500 Hrs on all working days on submitting an application in writing enclosing a DD BPO for an amount of Rs1000 Rupees One thousand only drawn in favour of ESIC A c No 1 payable at Bengaluru amp issued by any nationalised bank b The last date for submission of duly filled in applications alongwith all enclosures as mentioned in this document is 4 09 2012 1500 Hrs No applications submitted after the due date or time shall be accepted by the hospital under any circumstances In the event of the day of
37. his document at the time of execution of the Agreement The Bank guarantee should be for a period covering the entire CMC AMC service contract including the warranty guarantee period The Bank guarantee should be submitted within a period of 15 days after the placement of the supply order or supply of the equipment whichever is earlier failing which the order is liable to be cancelled and the Earnest money forfeited The Bank guarantee is returnable to the equipment supplier on completion of the normal operating life of the equipment The hospital reserves their right to invoke the Bank guarantee if any of the terms amp conditions of the supply is not met by the supplier The Earnest Money is returnable to both the successful and other bidders after the submission of the Bank guarantee and within three months from the completion of the tendering process respectively The hospital does not pledge itself to accept the lowest or any other tender and reserves it s right to accept the whole or any part of the tender or portion of the quantity offered and the bidder shall be required to supply the same at the rate quoted The hospital reserves it s right to accept or reject any or all the tenders without assigning any reasons there of CUSTOMS CLEARANCE The equipment requiring import from abroad shall be done so under the OGL scheme for which tenderer will ensure before shipment takes place that the equipment in question can be imported u
38. hite perimetry SAP Dynamic Adaptive step size 5 8 min Normal 4 2 1 bracketing 8 12 min BT BG FG Esterman Country dependent static expert opinion Test Country dependent automatic kinetic test Custom Test individual test patterns Features Fixation Real time fixation amp Blink Control Automatic Averaging pupil measurement Non contact head recognition sensors Ehternet access and PC software One click testing follow up button Lens distance control LVS Low Vision Goldmann V 2 LT 1 LT Test Library G Physilogical Glaucoma Test M Physiological Macular Test 5 12 30 32 ST LVC 07 LVP D1 N1 30 2 24 2 10 2 Electrical amp Mechanical Specifications Power Requirements Operating Temperature Light Source life span Conformity Measures W x L x H Weight 100 120VAC 220 240VAC 50 60 Hz 15 C 40 C gt 20 000 hrs for stimulus background and fixation CE 93 42 EEC 89 336 EEC conformity module A CSA C amp US 648mm x 519mm x 796mm 25 Kg LED WIRELESS BINOCULAR INDIRECT OPHTHALMOSCOPE NO 492 U 16 30 2012 L 4 OPTHAL IPD Adjustable 47 75mm d Light Output Rheostat control for illumination e Standard Accessories Cobalt B lue UV Filters green filter teaching mirror sclera depressor rechargeable battery pack charger for battery branded original case for IDO Detachment charts colour pencils 2 spare bulbs LED Halogen AUTOMATED LENSOMETER W
39. i Cad rechargeable batteries e 6 foot EMG sensor cable e Leather strap for ambulatory use e Quick Stick pre gelled disposable EMG electrode sets e Top cover instruction label e Carrying case e User manual FINGER DEXTERITY TEST NO 492 U 16 30 2012 D 2 OCC TH Light weight portable durable and storable after use Wooden material should be laminated Cabins for Tweezer S S Plain pins S S Screws washers and nuts Set should consist Laminated board has 100 holes to place in pegs amp covered recess to store parts e Tweezer S S e Plain pins S S Screws washers and nuts CEREBRAL PALSY CHAIR NO 492 U 16 30 2012 D 3 OCC TH Cerebral Palsy chair should be made up of wooden material and polished Foam padded for seat back rest leg and foot rest and for forearm support Straps should be provided for chest hip forearm leg and foot Seat height width and back rest should be adjustable Should be provided with caster wheels with lock for mobility and stability HAND DYNAMOMETER ELECTRONIC WALL MOUNTED NO 492 U 16 30 2012 D 4 OCC TH Hand Grip Digital Dynamometer with electronic Strain gauge Should be suitable for routine screening work amp evaluating max strength of subjects grip Unit should be wall mounted The sealed system should be with peak hold facility register force in 1kg graduation from 0 to 9kg ensuring a high degree of accuracy HAND EVALUATION KIT JAMER NO 492 U 16 30 2012 D 5 OC
40. irms registered under the Indian Partnership Act the capacity in which signing e g Secretary Manager Partner etc or their attorney and produce copy of a document empowering him to do so if called upon to do so Note In case of unregistered firms all the members or all attorneys duly authorized by all of them or the Manager of the firm should sign the tender and subsequent documents ADDRESSING THE TENDER The tender documents should be addressed to The Medical Superintendent ESIC Hospital 5 Main Road FTI Campus Yeshwanthpur Industrial Sub urb Bengaluru 560 022 PREPARATION OF TENDER a b c d e Tenders should be prepared in three separate covers for i Price bid in triplicate ii Technical bid in triplicate and iii Bid Guarantee all three duly sealed superscribed and addressed to the hospital All the above referred three envelopes should be placed in a big envelope which will form the main cover This main cover must be superscribed Tender for due on at Hrs The technical bid should contain precise technical operating amp maintenance details Any limitations or extension of the requirement should be clearly spelt out Bids not giving the precise technical details are liable to be rejected The operating and service manual of the equipment should accompany the technical bid The Price bid should contain quotes both in figures amp words Bids not giving the quote in words are liable t
41. is Bilateral Motor Coordination Praxis on Verbal Command Constructional Praxis Postrotary Nystagmus Motor Accuracy Sequencing Praxis Oral Praxis Manual Form Perception Kinesthesia Finger Identification Graphesthesia Localization of Tactile Stimuli ACTIVITY MATTRESS NO 492 U 16 30 2012 D 10 OCC TH Foam material covered with dark colour rexin with zip lock at one side e extra rexin cover e I1XbXh 190 X100 X 10 cms e Durable for heavy use ANKLE EXERCISER NO 492 U 16 30 2012 D 1 OCC TH e Should hold the foot in a foot moulde e Straps to hold foot in place Mounted on a laminated base with stainless steel sheet bracket having two springs for ankle exercises The resistance of these units can be increased further by tightening spring s nut CONTINUOS PASSIVE MOTION UPPER EXTREMITY NO 492 U 16 30 2012 D 12 OCC TH CPM for MCP PIP amp DIP joints of index middle ring amp little fingers Should be light weighted amp user friendly Forearm amp wrist straps to secure the CPM while in action Intermittent amp continues movement option to be provided Should be rechargable and comply with 240 V AC amp Indian plug pin Supplied with English instruction guide Should be provided with guarantee amp warranty ERGOMETER MX 1 NO 492 U 16 30 2012 D 13 OCC TH Compact amp heavy duty for hospital use Must have training programs Should have Electronically controlled brake Seat filled with gel ve
42. m amp numeric display The waveform should be user selectable e Should be able to monitor ECG SPO NIBP Temperature simultaneously e Should be portable with carrying handle and weight not more than 5 K G with battery e Monitor should have built in lithium ion type battery for 4 hrs continous operation in case of power failure e Should have key for quick access to main functions e Five lead ECG monitoring with lethal arrththmia recognition and capability for ST analysis e Should have respiration and apnea alarm e Manual auto amp stat modes for NIBP monitoring and range should be 2 to 230 mm Hg e Should have separate volume control for beep sound QRS and alarm sound s Facility for last 24 hours critical alarm review and facility for patient data entry e Equipment performance should not be affected by electromagnetic fields or that conducted through power lines from other devices e Should work on 220 to 240 Volts 50Hz with in built re chargeable battery e Should provide following accessories a Re usable adult pediatric SPO2 finger probes one pair each at least b Adult and pediatric NIBP cuff s of different sizes one pair each at least e Should have safety certificate from a competent Indian authority or CE FDA or valid detailed and functional safety test report from ERTL as the case may be Copy of the certificate test report should be submitted along with the technical bid K MEDICINE NO 492 U 16
43. measuring tape e Lower plank 30cm wide with 6 slots to hold upper plank for angle adjustment Sand blocks 3 pairs with different grasp holds amp clips to fix sandpaper TILT TABLE ELECTRICALLY OPERATED NO 492 U 16 30 2012 D 20 OCC TH Electrically operated to tilt the table Foam padded top Straps to hold the patient Heavy duty motor for silent and smooth lifting action with easy to operate control switches Range adjustable between 0 to 85 degrees e Table top 61cm wide x 198cm long x 80cm high e Fitted on a heavy duty tubular steel frame with four locking wheels of 10 cm dia for easy mobility e Work on 220V AC SWING VESTIBULO PROPRIOCEPTIVE EQUIPMENTS NO 492 U 16 30 2012 D 21 OCC TH Large frame of iron railing for suspension of swings over it Net swing 5 ft L x 2 ft W strong nylon net Edges having piping of canvas cloth 4 diameter 4 nylon ropes and 1 diameter 2 hooks for suspending swing Weight bearing capacity up to 55 kg Platform swing 32 L x 17 W 1 thick platform covered with Rexene nylon Platform tobe suspended to the ceiling with 2 diameter 4 nylon ropes 1 diameter 2 C hooks Weight bearing capacity up to 55 kg Bolster swing 8 diameter coir material cylindrical piece covered with nylon Rexene 1 diameter circular hooks at each end 4 diameter 2 nylon ropes and 1 diameter 2 C hooks for suspending the bolster to the ceiling Weight bearing capacit
44. ment in working order ee During the guarantee warranty period the replacement of any part s components of the equipment or rectification of defects of works will be free of cost In case of any replacement during guarantee warranty period all formalities connected with such import of replacement shall be completed by the tenderer with the assistance of the hospital as required Further the defective parts equipment shall be returned by the hospital to the supplier after replacement ff If there are any parts that are consumable in nature which are not covered under the above said guarantee warranty clause then details of same with nomenclature etc must be furnished gg The tenderer should submit a certificate that the equipment being offered is the latest model as per specifications and that spares for the equipment will be available for a period of at least 10 years after the warranty period The tenderer should also certify that they will keep the hospital informed of any update of the equipment over a period of next 5 years and undertake to provide the same to the hospital at no extra cost hh The tenderer will guarantee that they will regularly supply any items of spare parts requisitioned by the hospital for satisfactory operation of the equipment till ii aD the completion of the normal life span of the equipment as and when required on agreed basis for an agreed price The agreed basis could be an agreed discoun
45. nder the said scheme It will be the responsibility of the tenderer to get the customs clearance of the equipment with the assistance of the hospital as required by way of providing any letters authorisations etc The tenderer will pursue any claims with the custom authorities insurance company cargo operators and transporters as may arise at any stage The N MLC Not manufactured in India Certificate the duty exemption certificate and any other documents required for custom clearance will be provided by the hospital INSURANCE The tenderer will ensure that the equipment is properly insured for the full CIF value to cover the transit upto installation site amp period If the installation is delayed beyond the agreed date of satisfactory installation commissioning and handing over of the equipment then in that event any transit and storage damages which come to light after such delays shall be at the sole risk responsibility and cost of the tenderers z The tenderer shall provide to the hospital after the inspection a detailed list of any loss or damage to the equipment that may have occurred so as to enable the hospital to file appropriate claims with the Insurance Company However it shall be the responsibility of the hospital to prepare lodge and pursue any claims that may arise with the Insurance Company aa The tenderer shall provide all assistance in pursuing any such insurance claims expeditiously The tenderer shall
46. niform rays to the bed surface b Under Surface unit Microprocessor controlled Irradiance 18u w em2 nm Energy efficient 6 CFL blue light Should have convenient baby bed with transparent acrylic fiber body leak proof with transparent acrylic side railings Up amp down tilt facility of bed should be available upto 30degree The lower surface should be detachable from the main unit so as to use under radiant warmers One unit should be on movable wheels with brakes Should have internal amp external reflectors designed to avoid wastage of light rays Microprocessor control for 1 Lamp usage 2 Dose time 3 Feeding alarm 4 Display of set time 5 Auto cut off 6 Automate facility System should confirm to CE IE standards and should be ISO certified NEONATAL OPEN CARE SYSTEM NO 492 U 16 30 2012 F 5 PED Unit consisting of Warmer n CPAP Optional Pulse Oxymeter Baby Weighing Scale Optional and Motorized Height Adjustment EV Specifications Operating temperature range 20 38 C Operating Humidity range 0 100 RH Power requirements Voltage rating 230 V Should have self setting microprocessor based servo control system Skin temperature probe should have Range 26 4 C 40 C Accuracy 0 2 C Resolution 0 1 C Probe interchangeability 0 2 C Servo Infant required Temperature range servo 32 C 38 C Should have following alarms Audio amp Visual alarms
47. o 500ml hr Bolus Rate 10 ml 100 ml hr 20 ml 200 ml hr 50 ml 500 ml hr Battery Type Lithium Polymel battery Life gt 2 hours continous running BLOOD GAS ANALYSER NO 492 U 16 30 2012 N 3 ICU Fully automatic fast amp latest blood gas analyzer for the analyses of blood gases Measures pH pCO pO Hct amp Barometric pressure Upgradable to measure Na K Cl Ca Calculated parameters which includes pH pCO pO at patient temperature BE BE BE e BB HCO3 CtCO2 stHCO stpH ctO aH AaDO P50 Qs Qt a Ao2 avDo2 AG OER PAO2 Respiratory index etc Direct aspiration of samples from syringe capillaries QC ampoules Cups Test tubes with out the use of any adapters Sample volume 75 ul max s Sample throughput 30 samples hour Fast analysis time maximum 50 sec to results Maintenance free electrodes including reference electrode with individual electrode ON OFF facility Fully automatic liquid calibration of all parameters at user defined intervals without the use of external gases tanks amp regulators Continuos reagent level monitoring with graphic display Automatic sample device recognition Data display on well illuminated LCD color touch screen display Data printout on built in graphic printer with cutter Storage facility of measured data in case of power failure Built in data storage facility for at least 1000 patient amp QC results and provision for op
48. o be rejected In addition to quoting for the equipment as per the format the tenderer must also quote the charges and terms and conditions of CMC AMC service for a period of 5 five years for maintaining the equipment at this hospital after the expiry of the period or warranty guarantee The service contract charges should be quoted only for labour which will include the cost of the engineer s support staff s time travel etc and excluding the cost of any replacements components that may be required at the time of providing such service DELIVERY OF TENDER DOCUMENTS a The bids should be submitted to the office as detailed elsewhere in this document within the stipulated date amp time No relaxations exceptions will be permitted in this regard under any circumstances b The price bid Bid Guarantee should be kept valid for acceptance for a period of 180 days after opening of the tender c The purchaser will not be responsible for any postal delay or any other cause that may lead to delay in the receipt of the tender documents in this office beyond the stipulated date and time stated in the tender documents WHO CAN BID a b c d Only manufacturers or their sole authorized distributors sole agents are entitled to submit the bid documents All offers other than from the manufacturers should be supported by an authority letter in original from the manufacturer s authorizing the firm to submit bids on t
49. on with this purchase shall be served by either party within 30 days of the beginning of such dispute failing which all rights and claims shall be deemed to have been forfeited and absolutely barred ccc Before proceeding with the reference s of arbitration the arbitrators shall appoint nominate an Authority who shall be the Medical Superintendent of the hospital In the event the arbitrators do not agree among themselves on their findings the authority so nominated appointed shall enter upon the reference and his award shall be binding on both the parties The venue of the arbitration shall be at ESIC Hospital 5 Main Road FTI Campus Yeshwanthpur Industrial Suburb Bengaluru 560 022 ddd The provisions of the Indian Arbitration and Reconciliation Act 1996 and of rules framed thereon and any statutory modification thereof shall be deemed to apply and be incorporated for the supply installation and commissioning etc eee Upon every or any such reference the cost incidental to the reference and award s shall be at the discretion of the arbitrators or in the event of their not agreeing of the authority appointed by them respectively who may determine the amount thereof and direct the same to be fixed as between solicitors and client or as between parties and shall direct by whom and in what manner the same shall be borne and be paid fff JURISDICTION The courts at Bengaluru alone will have the jurisdiction to try any matter dis
50. pacity up to 140 kg THERMOPLAST SHEETS 10 SHEETS NO 492 U 16 30 2012 D 25 OCC TH e Thermoplastic sheets of 5mm thickness perforated type 10 sheets of standard size Degree of perforations 38 Should have 100 percentage plastic memory Should be light skin coloured SPLINT THERMAL BATH NO 492 U 16 31 2012 D 26 OCC TH Stainless steel splint thermal bath with split cover should hold an 18 x 24 sheet of thermoplastic material Should be Water resistant illuminated on off switch and digital LED temperature controller Temperature adjustments from 140 F 180 F with preset temperature facility Internally insulated with microprocessor controls to ensure correct and constant temperature Durable plastic handle to minimize contact with warm lid surface Drain valve fuses and power cord should located at rear of appliance Should comply with Indian power standards 220V Ac Should be supplied with max guarantee amp warranty period Insulated amp comply high standards FOAM PAD ETHA FLEX 10 SHEETS NO 492 U 16 31 2012 D 27 OCC TH 3mm thick flex sheet 10 sheets 1 roll of standard size Light or skin coloured Soft amp durable to with stand constant pressure Supplied with one side pre adhesive amp ready to use Compatible with thermoplastic material for binding with adhesive WHEEL CHAIR NO 492 U 16 31 2012 D 28 OCC TH Should be light weight folding type with removable armrests and swinging foo
51. pedal RPM ISO Strength program an accommodating resistance program should be there adjustable seat hight front back Durable maximum user weight 200 Kg Display of energy expenditure in particular time and speed of exercise with user manual RRKKDSS SCC CHEE
52. pute on reference between the parties arising out of the contract It is specifically agreed that no court outside shall have jurisdiction in the matter ggg FORCE MAJEURE Any failure of omission or commission to carry out the provisions of the contract by the tenderer shall not give rise to any claim by any party one against the other if such failure of omission or commission arises from an act of God which shall include all acts of natural calamities such as fire flood earthquake hurricane or any pestilence or from civil strikes compliance with any statute and or regulation of the Government lockouts strikes riots embargo or from any political or other reasons beyond the tenderer s control including war whether declared or not civil war or state of insurrection provided that notice of the occurrence of any event by either party to the other shall be given within two weeks from the date of occurrence of such an event which could be attributed to Force Majuere conditions hhh TERMINATION FOR INSOLVENCY The hospital may at any time terminate the contract by giving written notice to the tenderer without compensation to them if they became bankrupt of otherwise insolvent which events shall of themselves be a breach of the contract on the part of the tenderer provided such termination will not prejudice or affect any right of action or remedy which has accrued or will accrue thereafter to the purchaser iii TERMINATION FOR CONVE
53. quipment will be maintained in good working condition for a period of 347 days out of a period of 365 days i e 95 Uptime Non functioning of the equipment for a period of 8 eight hours shall be considered as one day down time Essential period to shut down the equipment fully or partially shall also be included in the down time while calculating the 95 guaranteed uptime No deduction or advantage of any kind on account of Sundays half days on Saturdays public Govt holidays observed by the hospital shall be allowed from the total down time permissible as defined above except that such of Sundays half days on Saturday Pubic Govt holidays on which the hospital is not able to provide facilities for service repairs of the equipment shall be excluded for counting the downtime This guaranteed uptime shall be calculated for each block of 365 days The firm will be required to pay a penalty of Rs1 000 Rupees One thousand only per day in case the number of days of downtime in each period of 365 days is more than the downtime permissible which is to be calculated as defined above and the delay for not bringing the equipment in functioning order is in any way directly or even partially attributable to the tenderer Further the penalty will apply only for the number of days the permissible down time as defined above is exceeded For the purpose of calculation of down time any downtime period less than 8 hours shall be excluded During the CMC
54. rtically and horizontally adjustable Deep entrance Load control independent of rotational speed Transport rollers at the front Training computer with following features Graphic representation of the load profile Training evaluation Performance into watts Chronometry Energy consumption Training distance Speed Technical data Performance 25 to 400 watt Loading capacity 150 kg MEDICINAL BALLS 1 5 KG NO 492 U 16 30 2012 D 14 OCC TH Must have wooden cabinet with shelf to hold five balls Should have out ward swing doors with glass panel and handles Balls must be made out of leather securely stitched with strong leather cord Set of 5 balls in different sizes with 1 2 3 4 5 kgs each NIRMAL TABLE FOR HAND EXERCISER NO 492 U 16 30 2012 L 15 OCC TH Hand exerciser must be Hard wood table with laminated top size 24 x 30 x 30 high fitted with 6 pulleys in a steel frame Leather loops and nyloncord passing through the pulleys with hanging weight underneath for fingers hand wrist and forearm exercises Supinator pronator and wrist circumduction wheel for wrist exercises Five sets of weights each set consists of 5 weights of one each of 100 200 300 400 and 500 gms PEDDO CYCLE NO 492 U 16 30 2012 D 16 OCC TH A motorized pedo cycle should have digital meter to display the workout Should be designed to improve movement range muscle power and coordination ability of limb joints Should come
55. ry e Synchronizer and cardiovession e Unique disarm button in addition to automatic time delay e Should come with higher resolution monitor e Should come with 3 lead ECG that can be measured from cables adult external paddles pediatric paddles e Heart rate 20 to 300 bpm with user selectable alarms e Should come with extended pacing demand and asynchronous modes e Should display cpr in real time e Should have large memory that stores and prints 25 ECG events e Battery to last not more than 2 hrs of continuous ECG monitoring or 30 full energy discharges e Battery indicator on display and self test on battery e Accessories needed a Paddle with remote energy selection charge and discharge buttons on paddles b Paediatric paddles adaptors set of 2 c A C 240 V TO 50 HZ charger and main power source adult paddles and test paddles d 3 lead patient cable e One spare battery f Roll of 50mm recording paper x 10 rolls g 5 oz tube of defibrillator gel x 5 tubes h External disposable pacing pads 2 sets I Operation manual service manual complete SYRING PUMP NO 492 U 16 30 2012 N 2 ICU Accept all standard syringe of 10m1 20ml and 50ml Built in double CPU Powerful alarm system with both Audible and Visible alarms Water proof Moisture proof Anti interference Anti high and low temperatures Injection rate 10 ml syringe 0 1 hour to 100 ml hour incrant 0 1ml hr 20 ml syring 0 1ml hr to 200 ml hr 50 ml syringe 0 1 ml hr t
56. step magnification changer NO 492 U 16 30 2012 C 1 ENT Focusing system internal manual continuously adjustable from 200mm to 415mm Continuously adjustable via hand grip or foot control panel Working length 200mm to 415mm Magnification manual Galilean 1 6 in 5 steps Optics Apochromatic Main binocular tube straight tube 0 degree with 12 5 x or 10 x wide field eye pieces Main illumination and back up xenon lamp fast action changer Filters UV IR Automatic lamp changer Stand floor stand Voltage 115V 230V Frequency 50 to 60 Hz Power consumption 115v max 10A 230 V max 8 A Automatic circuit breaker Accessories Stereo co observation tube Camera suitable 3 chip CCTV camera UPS 1000VA 6Amp 1500 10 Amp Desktop computer branded with 21 LCD medical grade monitor Intel C2D 2 66 GHZ 2GB RAM 500 GB Hard disk DVD RW n VIDIA 9300 GE 512 MB dedicated Graphics LAN Card reader 2 1 speaker mike In built TV Tunner card Vista Home Premium Multi Media key board mouse wireless LAN Desktop trolley CLINICAL DIAGNOSTIC PURE TONE AUDIOMETRY NO 492 U 16 30 2012 C 2 ENT Two channel audiometer Pure tone channel 1 and 2 Frequency range Air conduction 125 Hz to 12000Hz Bone conduction 125 Hz to 12000 Hz Speech Channels 1 and 2 Microphone intensity range Masking intensity range Signal format Special test for cognition Communications amp monitoring Autom
57. t on the published catalogue price or an agreed percentage of profit on the landed cost The tenderer will further guarantee that the hospital will be given advance notice before the parts components etc of an equipment goes out of production so that the hospital will be in a position to procure the required quantity of these parts components to ensure that the equipment completes it s normal life span without any irreparable break downs The tenderer should guarantee that they will make available to the hospital the blue prints and drawings of the spare parts if and when required in connection with the equipment kk UNDERTAKING The tenderer shall furnish the undertaking alongwith the 1 tender document to the effect that the goods stores articles supplied to the hospital under this contract shall be of the best quality and workmanship and shall be strictly in accordance with the specifications and particulars contained mentioned in the clause here of and the tenderer hereby guarantee that the said goods stores articles conform to the description and quality aforesaid The hospital will be entitled to reject the said goods stores articles or such portion there of as may be discovered not to conform to the said description and quality And on such eventuality the goods stores articles will be at the tenderer s risk amp responsibility and all the provisions here in contained relating to rejection of goods etc sh
58. t rests Should be fitted with push breaks which needs minimal effort by patient to stop the wheel chair Removable armrests should be fitted with S S guard and P U rubber foamed Foldable and swinging footrests must be separately detachable and fitted with leg supporting belt Multi directional caster wheels should be free to move and turn 180 degrees Hand rim should be non slippery to ensure better grip MULTI ACTIVITY WORKSTATION NO 492 U 16 31 2012 D 29 OCC TH 6 ft Lx 4 ft W x 4 ft H teak wood box with in built shelves for storage 3 hinged work surfaces 2 at sides 1 at front which can be closed back after use Work surfaces at sides should be 2 ft L x 4 ft W and 1 4 gauge thick Work surface at front should be 6 ft Lx 1 2 ft W and 1 2 gauge thick Finely polished surfaces and rounded edges and corners Freely rotating ball wheels at each corner of box base It should contain pinch tree PVC pipe tree 25 hole peg board multi shaped peg board bolt board assembly finger dexterity board door latch board dressing board shoulder ladder hand exercise board Velcro hand gym board activities E PHYSIOTHERAPY HAND EXERCISER NO 492 U 16 30 2012 E 1 PHY Digi flex hand exerciser develops isolated finger strength flexibility and co ordination while building hand and forearm strength 5 different resistance levels UPRIGHT BI DIRECTIONAL BIKE NO 492 U 16 30 2012 E 2 PHY Display of no minimum
59. ter Case High impact ABS plastic with lexan overlay on membrane touch switches 1 0 H x 2 42 W x 3 88 D Train of Four 4 pulses 2 s repeats every 10 secs Output Current 0 70 Ma Adjustable in 0 1 mA increments HI Range 0 6 0 mA ADJUSTABLE IN 0 1mA increments LO Ranges Display Resolutions 0 1 mA Dimensions 5 5 long x 1 5 wide amp 1 thick Size 2 09 Hx 3 60 W x 5 75 D Weight 11 oz including battery Warranty 1 year parts and labor Should have a current range from 0 1 to 5 mA Should have a resolution of 0 01 Ma Should have a digital display for current Should have short stimulus pulse duration of 0 1 ms Should have a frequency range from 0 1 to 99 Hz Should be able to monitor single twitch Train of four PTC and DBC Should have integrated electrode cable with lead Should be battery operated Should be supplied with 5 sets of insulated needles in varied length 0 Should have safety certificate from a competent authority CE STQC CB certificate STQC S certificate or valid detailed electrical and functional safety test report from ERTL Copy of the certificate test report shall be produced along with the technical bid FS OOO SOON Seca Nour N ICU NO 492 U 16 30 2012 N 1 ICU BIPHASIC DEFIBRILLATOR e Biphasic fully automatic e Waveform display e External energy from 2J TO 200J biphasic e changing time less than 8 seconds 200J with a changed batte
60. ting the baby Equipment should confirm CE IEC Standards and ISO certified Equipment should be movable with wheels and brakes RESUSCITATION WARMER NO 492 U 16 30 2012 F 6 PED The unit is used for resuscitation of babies in labour ward operation theater Should be a mobile unit mounted on at least 100mm castor Base of the unit should be built such that it allows the caregiver leg to move freely below the bed of the unit without any hindrance The pillar supporting the control panel and heated unit should be on 1 corner of the bed to allow free access on all four sides of the baby bed Should be able to swivel the heated unit to accommodate X ray unit Infant bed should have provision for X ray cassette holder the sides of bed should have marking to enable easy positioning of X ray cassette Should have integrated Halogen examination lamps Should have I V pole Should have swivel able monitor tray Should have three different positions on the pillar to mount monitor tray The bed of the unit should be at least of following dimensions Mattress size 8300X500X45mm Bed size 830X520X210mm Side panel covering the bed should at least 110 mm above mattress Side panel should be easily removable for cleaning Should be able to tilt bed on either side max 8 degrees and should be able to position at any tilt as per the caregiver requirement The wheels should be atleast four inches and with at least two lockable wheels
61. tional PCMCIA card Built in QC analysis software for Levy Jennings West guard rule etc Built in barcode scanner FLUID BLOOD WARMER NO 492 U 16 30 2012 N 4 1CU e Numerical display for real time temperature setting temperature e Accuracy 0 50 degree C e Temperature setting 33 degree to 42 degree C adjustable at rate 0 1degree C e High temperature cut off setting temperature 1 degree C 43 degree C 48 degree C 3 degree C Low temperature alarm Setting temperature 1 degree C e Uses normal transfusion infusion tubing e Recommended flow rate 0 to 16 ml min D OCCUPATIONAL THERAPY DUAL CHANNEL EMG NO 492 U 16 30 2012 D 1 OCC TH e Should be easy to use and portable e Surface EMG for single site dual site and ratio A B monitoring e Should provide both easy to understand patient feedback and statistical information Audio Patients should easily hear the changes in their EMG activity Feedback should be provided continuously above threshold or below threshold Visual Should provide easy to see visual feedback for each channel with bright LED numerical EMG SPECIFICATIONS Channels Two Independent Channel A Only B only A B ratio A B simultaneously Visual Feedback per channel Display options Numerical LED lightbar lightbar only Numerical LED only Settings 0 5 1 0 2 0 4 0 6 0 10 0 60 0 seconds LVA last vaule attained Continuous maximum minimum
62. with resistance control mechanism Should be compact and withstand for heavy duty Light weight and portable Should be provided with English user manual Should comply with Indian power standards 220V Ac SANDING UNIT OVERHEAD WITH STAND NO 492 U 16 30 2012 D 17 OCC TH Should have heavy amp wide based stand adjustable in height Semi circulator wooden plank with 6 wide should be fitted in the stand Roller should be covered with emery cloth for resistance Seat with back rest should be provided Whole assembly and chair should be fitted over a platform which should be non slippery SANDING UNIT VERTICAL WALL MOUNTING NO 492 U 16 30 2012 D 18 OCC TH Wooden wall mounting sanding unit with 20cm width x 100cm length fitted on an angular metal frame for angle adjustment and should have six weight plates 1kg each for resistance and one sanding block e Block should be covered with felt for resistance SANDING UNIT WITH ADJUSTABLE INCLINE FOR RECIPROCAL EXERCISER NO 492 U 16 30 2012 D 19 OCC TH Consists two wooden hinged planks e Upper plank s angle of inclination should be adjusted from horizontal to vertical position e Two pulleys fitted at the top of 30cm wide upper plank for reciprocal hand shoulder exercises three sets of sanding hand blocks with different grasp holds to be provided with the unit e Unit should be made of wood amp polished specifications e Upper plank 30cm x 100cm high with center divider with
63. xerciser 1 1595 3190 2 NO 492 U 16 30 2012 E 2 PHY Upright bi directional bike 2 3160 6320 The application fee is non refundable GROUP 4 Date of opening Technical bids 20 09 2012 Date of demonstration of equipment by tenderers qualifying in Technical bids 21 09 2012 Date of opening of Financial tenders of tenderers qualifying through technical bids amp demonstration 22 09 2012 Detailed information with all terms and conditions are given in the Tender Document Application forms and the tender documents can be obtained in person from Central Stores of the office of the Medical Superintendent by giving a request letter on letter head of the tenderer along with a crossed DD Banker s Cheque for Rs 1 000 Rupees One thousand only drawn in favour of ESIC a c NO 1 payable at Bangalore downloaded from our Website www esickar gov in amp www eprocure gov in Sd Medical Superintendent Application amp Tender document can be ANNEXURE 1 IMPORTANT INSTRUCTIONS TO TENDERERS Application forms amp tender documents are non transferable SIGNING OF TENDER Individuals signing tender or other documents connected with the contract specify i Whether signing as a Sole Proprietor of the firm or his attorney ii Whether signing as a Registered Active Partner of the firm or his attorney iii Whether signing for the firm Per Procurationem iv In the case of companies and f
64. y up to 55 kg Hanging ladder 1 2 diameter 2 ropes 16 L x 1 diameter wood sticks steel rods 12 gap between each step of ladder 6ft ladder hanging at least 4 ft above ground Weight bearing capacity up to 55 kg Trapeze swing 4 ft L 2 diameter wood stick steel rod suspended to ceiling by 1 2 diameter nylon ropes and 1 diameter C hooks Weight bearing capacity up to 55 kg Crash mat 6 ft L x 4 ft W coir material mat covered with nylon RAMP WITH CURBS NO 492 U 16 30 2012 D 22 OCC TH Ramp should be of wooden material Upper surface of the ramp should be non slippery Angle of inclination 2 inch raise for foot length Length x Breadth 7 ft x 2 5 ft Curbs are designed to be nested below the ramp at right angle BUBBLE BALL BATH NO 492 U 16 30 2012 D 23 OCC TH e The round pool should be 120cm in diameter x 50cm high amp has 10cm thick padded sides e The pool must contain 500 multi colour balls of 7cm or 8cm diameter e Pool side and bottom is covered with durable rexin that easily wipes clean and foam padded JUMP 200 TRAMPOLINE NO 492 U 16 30 2012 D 24 OCC TH e Large trampoline with stand to hold while jumping e With heavy duty frame and springs 38 D x 9 H trampoline should be covered in vinyl with reinforced stitching e Stands should be unscrewed during storage e Rubber feet for secure grip and protect floor e Handle 36 W x 44 H Weight bearing ca