Home

telephone hybrid

image

Contents

1. The function of the Connect switch is to connect the hybrid to the telephone line instead of the phone itself which is now switched off The led indicates that a connection has been made The function to caller is there to disconnect the outgoing signal to the caller for private discussions Manual page 8 Declaration of Conformity volgens ISO IEC leidraad 22 en EN 45014 Name Manufacturer D amp R Electronica Weesp b v Address Manufacturer Rijnkade 15B 1382 GS Weesp The Netherlands declares that the product Name product TELEPHONE HYBRID 1 Model nummer HYBRID Product options All Complies with the following product specifications Security EN 60950 1988 A1 A2 EMC CISPR 22 1985 EN 55022 1988 klasse B EN 50082 1 1992 IEC 801 2 1991 prEN 55024 2 1992 3kV CD 8kV AD IEC 801 3 1984 prEN 55024 3 1991 3 V m IEC 801 4 1988 prEN 55024 4 1992 0 5kV signal cables 1 kV power cables Additional info The product complies herewith to the following rules Low voltage 73 23 EEG EMC rules 89 336 EEG The product has been tested in normal users conditions Manual page 9 PRODUCT SAFETY This product is manufactured with the highest standards and is double checked in our quality control department for reliability in the HIGH VOLTAGE section CAUTION Never remove any panels or open this equipment No user serviceable parts inside Equipment power supply must be grounded at all times
2. Only use this product as described in user manual or brochure Do not operate this equipment in high humidity or expose it to water or other liquids Check the AC power supply cable to assure secure contact Have your equipment checked yearly by a qualified dealer service center Hazardous electrical shock can be avoided by carefully following the above rules PLEASE READ THE FOLLOWING INFORMATION Especially in sound equipment on stage the following information is essential to know An electrical shock is caused by voltage and current actually it is the current that causes the shock In practice the higher the voltage the higher the current will be and the higher the shock But there is another thing to consider and it is resistance When the resistance in Ohms is high between two poles the current will be low and vice versa All three of these voltage current and resistance are important in determining the effect of an electrical shock However the severity of a shock primarily determined by the amount of current flowing through a person A person can feel a shock because the muscles in a body respond to electrical current and because the heart is a muscle it can affect when the current is high enough Current can also be fatal when it causes the chest muscles to contract and stop breathing At what potential is current dangerous Well the first feeling of current is a tingle at 0 001 Amp of current The current between 0 1 Amp and
3. RJ11 am Telefon Nachfolgenden f hren wir die richtige Belegung der einzelnen Stecker auf damit der Telefonhybrid betrieben werden kann TAE Stecker Wandanschluss F Codierung Abk f r Fernsprecher Codierung Durch Nasen am TAE Stecker passen die Stecker von Telefonen immer nur in F Buchsen der Anschlussdose F Codierung TAE 6 F Stecker REESE i moi cao a ee Leitungsader vom Ger t a 5 b2 zuruck _ a Leitungsader vom Ger t o a2 zur ck F r den Betrieb des Telefons und des Telefonhybrids ist die Belegung 1 und 2 erforderlich RJ11 Stecker Western Stecker Belegung Telefonhybrid PHONE LINE 6 Kontakte davon 4 belegt Westernstecker 6P4C Die beiden u eren Kontakte fehlen 1 frei 2 frei 3 Laoderai a Leitungsader 4 Lboderb1 b Leitungsader 5 frei 6 frei www michael schoebel de Seite 1 von 3 12 2008 Technische Hinweise zum Anschluss des Telefonhybrids RJ11 Stecker Western Stecker Belegung Telefon Internationale Norm 6 Kontakte davon 4 belegt Westernstecker 6PAC Die beiden u eren Kontakte fehlen Telefone mit dieser Beschaltung funktionieren mit jedem Standard Kabel am Telefonhybrid 1 frei 2 frei oS 3 Laoder al a Leitungsader 4 Lb oder b1 b Leitungsader 5 frei 6 frei RJ11 Stecker Western Stecker Belegung Telefon z T Telekom Siemens 6 Kontakte davon 4 belegt Westernstecker 6P4C Die beiden u eren Kontakte fehlen F r den Betrieb be
4. careful not to touch a person being shocked as you yourself could also be shocked Once removed from the shock have someone send for medical help immediately Always keep the above mentioned information in mind when using electrically powered equipment Manual page 11 TELEPHONE HYBRID SERVICE MANUAL Manual page 12 Date 18 08 9918 08 99 16 1716 17 BILL OF MATERIAL D amp R Electronica Weesp BV SERVICE MANUAL Comp 100 60898508 Telephone Hybrid 1e 9 5 Articlecode Description Quantity Unit 10250345 Bridge rectifier BBOC1000 round 1 0000 st 10400233 Condensator ker 560p R2 5 1 0000 st 10400234 Condensator ker 680p R2 5 1 0000 st 10400235 Condensator ker 820p R2 5 1 0000 st 10401246 Condensator poly 1nO R5 0 1 0000 st 10401247 Condensator poly 1n5 R5 0 1 0000 st 10401248 Condensator poly 2n2 R5 0 1 0000 st 10401249 Condensator poly 3n3 R5 0 1 0000 st 10401250 Condensator poly 4n7 R5 0 1 0000 st 10401251 Condensator poly 6n8 R5 0 1 0000 st 10400278 Condensator poly 8n2 R5 0 2 0000 st 10401253 Condensator poly 10n R5 0 1 0000 st 10400273 Condensator poly 12n R5 0 1 0000 st 10401263 Condensator poly 180n R5 0 1 0000 st 10400280 Elco 2 2uF 50V radiaal R5 0 1 0000 st 10400293 Elco 220uF 63V radiaal R5 0 2 0000 st 10400281 Elco 4 7uF 50V radiaal R5 0 1 0000 st 10600432 Jack chassis break 2 0000 st 10600445 Conn Chass 805 D 4p RJ11 2 000 st 10300791 Potm 12 1x1KA lin 1 0000 st 10200530 PCB Telephone hybrid C
5. 0 2 Amp is fatal Imagine that your home fuses of 20 Amp can handle 200 times more current than is necessary to kill How does resistance affect the shock a person feels A typical resistance between one hand to the other in dry condition could well over 100 000 Ohm If you are playing on stage your body is perspiring extensively and your body resistance is lowered by more than 50 This is a situation in which current can easily flow Current will flow when there is a difference in ground potential between equipment on stage and in the P A system Please do check if there is any potential between the housing of the mikes and the guitar synth amps which will be linked by your body on stage Imagine a guitar in your hand and your lips close to the mike A ground potential difference of above 10 volts is not unusual in improperly wired buildings it can possibly be as high as 240 volts Manual page 10 Although removing the ground wire sometimes cures a system hum it will create a very hazardous situation for the performing musician Always earth all your equipment by the grounding pin in your mains plug Hum loops should be only cured by proper wiring and isolation input output transformers Replace fuses always with the same type and rating after the equipment has been turned off and unplugged If the fuse blows again you have an equipment failure do not use it again and return it to your dealer for repair And last but not least be
6. 1 0000 st 10550400 Switch Alps 2p ns 2 x om 1 0000 st 10550963 Switch Alps 4p sh 4 x om 1 0000 st 10550315 Switch rotary 1 x 12 1 0000 st 10950018 Transformer LM NP 1003 B PTT line 2 0000 st 10350517 Resistor OE 5 1 4W 1 0000 st 10350718 Resistor 120E 5 1 4W 1 0000 st 10350792 Resistor 604E 1 1 4W 2 0000 st 10350728 Resistor 820E 5 1 4W 1 0000 st 10250351 Zenerdiode 5V6 400mW 2 0000 st 10700631 Cap 11 0mm rond zwart 1 0000 st 10700665 cap 14 7mm 12 7x11 3 gat 1 0000 st 10450195 cap SiFam 11mm gray bulk 2 0000 st 10700975 Tape 12mm dun 20 0000 cm 10100371 Front 9 5 Telephonehybrid E 1 0000 st 10500084 Isolation panel 9 5 randapp PVC 1 000 st 10600436 Jack Nut 4 0000 st 10700685 Washer M 10 potmeter dun 2 0000 st 10150093 Frame 9 5 1HE version D 1 0000 st 10450253 Knob Pushbutton 3 3 grey square 2 0000 st 10450104 Knop SiFam grey D shaft 11mm 2 0000 st 10250387 Led 3mm red SLR 03A510 020 1 0000 st 20850531 PCB inserted Telephonehybrid 1 0000 st Manual page 13 Articlecode Description Quantity Unit 10700790 Taptite M3x6 verzkop pozidr zw 4 0000 st 10800924 Packaging 9 5 1 0000 st 10800956 Foamblock 9 5 2 0000 st Manual page 14 Technische Hinweise zum Anschluss des Telefonhybrids Anschlussbelegung RJ11 Keine Funktion des Telefons Manchmal kommt es vor dass ein Telefon nicht am Telefonhybrid funktioniert Dies liegt nicht an einem Ger tedefekt sondern an unterschiedlichen Anschlussbelegungen der Telefonleitungen
7. TELEPHONE HYBRID 1 USER MANUAL Vi Smart im Solution Dear Customer Thank you for choosing the Telephone Hybrid 1 This time you are not faced with a huge manual because it is simply not necessary because of the natural recognition of all functions on the user interface All functions are self explanatory and you will certainly appreciate the ergonomics of this design We are confident that you will be using the Telephone Hybrid 1 for many years to come and wish you a lot of success With kind regards Duco de Rijk PRESIDENT D amp R ELECTRONICA WEESP B V Rijnkade 15B 1382 GS WEESP HOLLAND The Netherlands Phone 0294 418 014 Fax 0294 416 987 Website http www d r nl E mail info d r nl Manual page 2 What is a Telephone hybrid Telephone hybrids provide the interface between professional audio equipment and the public telephone network They provide protection for your equipment and the public telephone lines allowing for varying line signals and line conditions Automatically canceling out the unwanted signal they also facilitate two way communication down a single telephone line Each hybrid has a telephone line connection a handset connection and separate connectors for audio input and output from a broadcast mixer or other professional audio source A large proportion of D amp R hybrids are used in radio and television broadcasting applications allowing external callers to be connected
8. handset LINE wall RJ 11 connector to connect with the public telephone network TO MIC INPUT Stereo jack output to be connected to mic input of the mixer TO CLEANFEED Stereo jack input to be connected to Mix Minus Clean feed N OPUTPUT 1 output of the mixer CONNECTION WIRING OF BOTH PHONE AND LINE RJ 11 CONNECTORS PHONE WALL RJ 11 FUNCTION CONNECTION Pini1 n c Pin 2 A telephone line In out Pin 3 B telephone line In out Pin 4 n c Manual page 5 WIRING OF AUDIO IN AND OUTPUTS STEREO JACK TO MIC INPUT TYPE CONNECTION TOCLEANFEED OUTUT Screen Screen ground Audio ground Tip Phase hot Audio Ring Non phase cold Audio SPECIFICATIONS Audio Inputs TO CLEANFEED OUTPUT Impedance 10k Ohm electronically balanced Common mode rejection gt 30dB Maximum inputlevel 26dBU Nominalinputlevwel 4dBu 0 Frequency response 20Hz 15kHz i ess sSSSS Connectors STEREO JACK TO MICINPUT Impedance lt 50 Ohm electronically balanced Common mode rejection gt 30dB Maximum output level 20dBu Nominal outputlevel 4dBu Bandwidth to telephone line 250Hz 4kHz 3dB ref 1 kHz i stsi is sSCS Telephone line impedance Nominally 600 ohm Telephone line impedance 300 ohm to 1500 ohm range Connectors STEREOJACK KZZKNNNNNNNNNNNNNNNNN GENERAL Distortion Less than 0 1 OdBu out Power supply PASSIVE Power consomption NONE Dimensions 1 HE front panel 482
9. is designed to create an easy connection between the public telephone line and your studio equipment The Hybrid has to be inserted between your telephone and the telephone line Connect the two wires of the telephone line s wall unit to the RJ 11 connector labeled LINE wall and connect the telephone appliance itself to the Hybrid s phone output on the RJ 11 connector labeled PHONE This can be done with standard available cable assemblies from your local phone shop Now the Hybrid is interfaced fully balanced between your telephone appliance and its connection to the outside world The hybrid can now split the send and return signals Now connect the hybrid s balanced audio input labeled TO CLEANFEED OUTPUT to a preferable balanced output of around 4dBu This output has to be the mix of all signals except the signal coming from the hybrid itself to avoid feedback An Aux output on your mixer will do as well as long as you keep the Aux send ofthe channel you return the phone signal on closed all other Aux sends need to be open or in broadcast mixers a clean feed is the best The Hybrid 1 stereo jack connector labeled TO MIC INPUT has to be connected to a Mic level input of your mixing console NOTE The output of the Hybrid has to be connected to a Mic input of the mixing console because the outgoing level is very low because of the passive circuitry inside the Hybrid WIRING SCHEME PHONE RJ 11 connector to connect with a
10. stimmter Telefone muss ein angepasstes Kabel verwendet werden sonst ist kein Betrieb des Telefons m glich 1 frei 2 Lboder b1 b Leitungsader 3 frei 4 frei 5 Laoderal a Leitungsader 6 frei Der Hersteller hat meistens folgendes Kabel im Lieferumfang TAE F RJ11 1 La oder a1 a Leitungsader gt 5 Laoderal a Leitungsader 2 Lb oder b1 b Leitungsader gt 2 Lb oder b1 b Leitungsader Wenn dieses Kabel in den Hybrid gesteckt wird ist keine Funktion m glich da das Ger t auf 3 und 4 funktioniert und nicht auf 5 und 2 www michael schoebel de Seite 2 von 3 12 2008 Technische Hinweise zum Anschluss des Telefonhybrids Hier der Belegungsplan als Gesamt bersicht Leitungsader Leitungsader frei frei frei frei oo F Codierung 01RO DN TAE 6 F Stocker 1 frei 2 frei 3 a Leitungsader 4 b Leitungsader 5 frei 6 frei 4 b Leitungsader 5 frei 6 frei 1 frei 2 frei 3 a Leitungsader 1 frei 2 frei 3 a Leitungsader 4 b Leitungsader 5 frei 6 frei oder Bei Nichtfunktion des Telefons ist die Belegun 1 frei 2 b Leitungsader 3 frei 4 frei 5 a Leitungsader 6 frei des RJ11 Steckers auf 5 und 2 zu ndern www michael schoebel de Seite 3 von 3 12 2008
11. to the studio mixing console Most of the other units are supplied to communication operations allowing extremely effective conversion between 4 wire audio circuits and standard telephone lines Specs Output balanced mic level 30db Input Line level O dBu balanced R C balance fully adjustable Separation more than 30db Manual page 3 Front panel lay out PWM O gt ELEPHONE DR u HYBRID N TOCALLER ON LINE CONNECT R a m C BALANCE 12 pole rotary switch to select the optimum side tone attenuation R BALANCE Internal potentiometer to adjust for optimum side tone attenuation Switch to temporarily connect the line wall connector to the Phone TO CALLER i connector appliance to be able to dial and make a connection ON LINE Line connect switch to connect and disconnect calls from the telephone line CONNECT Back panel lay out TO TO 4 rons 6 AYA SS wa usin 4 ELEDHONE MADE IN HOLLAND CAUTION HYBRID 1 RISK OF ELECTRIC SHOCK TIP HOT DO NOT OPEN RING COLD DANGER RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR SLEEVE GROUND PHONE RJ 11 connector to connect with a handset LINE wall RJ 11 connector to connect with the public telephone network TO MIC INPUT Stereo jack output to be connected to Mic input of the mixer TO CLEANFEED Stereo jack input to be connected to Mix Minus Clean feed N OPUTPUT 1 output of the mixer Manual page 4 USER MANUAL The D amp R Telephone Hybrid 1
12. x44mm Frame 240x44x175mm width x height x depth Weight 1 5 kg net including packing Manual page 6 AUDIO CONNECIONS TELEPHONE HYBRID TO OUR AIRMATE OR ANY MIXER AIRMATE TELEPHONE HYBRID NC RING TIP Cinch connector Jack connector Left cleanfeed output Cleanfeed input Tp Hot Ring Colt Shield Not connected Cleanfeed output could also be an AUX send output AIRMATE channel 8 TELEPHONE HYBRID GND RING XLR connector Microphone input Jack connector Hybrid mic level output 1 Ground Tip Hot 2 Hot Ring Colt 3 Cold Shield Ground Manual page 7 SETTING UP PROCEDURE Push the to caller switch and leave the connect switch in the up position Now dial the caller to whom you want to talk If this connection is made you connect the caller to the mixing console by pushing the connect switch Now listen by means of a PFL CUE switch on your mixer to the caller and adjust while talking the C and R balance so that the outgoing signal your voice is best attenuated A practical start is to put the C balance on number 7 and the R balance on 5 Carefully adjusting afterwards can be realized by slowly adjusting the R balance for optimum attenuation This is the basic setting for most of your calls because the line balancing to your own telephone station has to be performed one time only when no changes are made to the telephone system in your place The maximum attenuation will be around 22 to 26 dB

Download Pdf Manuals

image

Related Search

Related Contents

CBM Holzkessel  CB52400    6e Colloque Alpin de Soins Palliatifs "Alimentation, nutrition et  PAPI Solar Module User Manual  TAXE D`APPRENTISSAGE  APSコンパクトカメラの比較テスト結果[PDF形式]  silla auto travel manual de instrucciones  Steenkaai 22 – 23 8000 Brugge / Belgique tel + 3250314690 fax +  Comparaison des nombres relatifs Sommaire • Fiche d`identification  