1. Open both hot and cold faucets 4 Move the filter assembly into installation position sure the installation surface is level and smooth 5 Plumb IN and OUT connections to and from the filter e Be sure the incoming hard water supply is directed to the INLET port of the valve e The valve body of the control is marked with arrows indicating the proper flow direction Connections are illustrated below Outlet e Inlet Figure 1 CAUTION If making a soldered copper installation do all sweat soldering before connecting pipes to the bypass valve Torch heat will damage plastic parts CAUTION When turning threaded pipe fittings onto plastic fittings use care not to cross thread CAUTION Use Teflon tape on all external pipe threads Do not use pipe joint compound CAUTION Support inlet and outlet plumbing in some manner use pipe hangers to keep the weight off of the valve fittings Use Step 10 to install rigid drain pipe 6 To adapt a rigid drain pipe to the or HP04 system do not attach barbed hose fitting to valve Instead plumb rigid tubing directly to the 1 2 male NPT drain fitting 7 Cut and glue drain pipe to a suitable drain making sure it is secure 8 Place bypass valve in bypass position 1 Bypass 2 Service Outlet V mh BEEBE EE EE ens ee m Figure 3 9 Fully open the house main water shutoff valve 10 Slowly turn INLET
2. bypass valve back in the service position Allow water to flow into the unit 11 Push and hold extra cycle button to allow unit to go into backwash 12 Allow unit to run to drain for approx 5 minutes 13 Check plumbing work for leaks and fix immediately if any are found 14 Push extra cycle momentarily to allow unit to advance to rapid rinse 15 Allow unit to run to drain for the duration of the cycle 10 minutes Figure 4 With the valve In Service manually initiate a backwash as the final installation step This backwash will a Complete the final flushing and filtering of the water system b Re classify the media bed if the bed was disturbed during shipping c Rinse any remaining residue from lines Filter Operation Backwashing consists of three cycles 1 Backwash Position Backwash is a rapid upward flow of water that loosens the media bed and flushes iron particles dirt and sediments filtered in the bed out to the drain 2 Fast Rinse Position Fast Rinse is a fast flow of water down through the media tank that follows a Backwash This flushes all remaining organics from the tank and packs the carbon bed for efficiency 3 Service When the filter is In Service it is flowing water through the system and removing objectionable materials from your water Troubleshooting 1 Filter Fails To Backwash 2 System Delivers un filtered Water 4 Loss of Water Pressure A El
3. INSTALLATION and SERVICE MANUAL HOUSEPURE MODELS HP03 and HP04 Table of Contents IMPORTANT SAFETY INFORMATION READ ALL e ee ee eee eee eene 3 P N 41482 Rev A 06 04 PEED WAVE Ret pee eo ouis Oe 4 POWER gratas d s 4 EA Tay ASE 4 0g HB c UNPACKING AND WHERE INSTALL THE WHOLE HOUSE 000000000000 INSTALLATION ipis 5 CONTROL START UP sess eee sess se FILTER OPERATION 2S BACRWASIEPOSPITIONA be ste eo duet nope eir e oeque ot 8 3 FAST RINSE POSITION sic iei 8 Doe SER WIG Beek pula al Ba Succes TEE 8 55525520 9 WATER SYSTEM PARTS LIST 4 CAUTION Read and follow the information this manual to minimize the risk of electric shock or personal injury IMPORTANT If you are unsure about installing of your water filter contact the helpline or consult a professional plumber IMPORTANT This system must be installed in compliance with applicabl
4. e state and local codes law and regulations Important Safety Information Read All Instructions Before Using Before beginning installation read all these instructions completely Then obtain all the materials and tools needed for installation NOTE Failure to install the HOUSEPURE system correctly voids the warranty Perform installation according to state and local plumbing codes e Handle all components of the system with care Do not drop drag or turn components upside down Be sure the floor under the water filter system is clean and level The system uses 120 volt 60Hz electrical power Always use the power cord supplied Plug power cord into an indoor 120 volt grounded outlet Install system in a protected area Be sure electric outlet and transformer do not come in contact with water See Where to Install the Filter in the installation section of the manual Always connect the system to the main water supply pipe before the water heater Do not expose system to freezing temperatures Water freezing in the system causes equipment damage e Minimum inlet water pressure is 40 psi Maximum inlet water pressure is 125 psi Use pressure reducing valve if necessary Equipment Overview Bypass Valve KDF MediaGuard Removes Chlorine and extends the life of the Activated Carbon only Premium Granular Activated Carbon Removes taste odors and THM s ScaleFree Water Conditione
5. ectrical service to unit has been interrupted B Timer programming bad improper programming A By pass valve is open H Improper programming L Unit is plumbed backwards N Water pressure is too low A Sediment buildup in Media Guard in water filter B Sediment buildup in carbon in water filter Assure permanent electrical service check fuse plug pull chain or switch Check programming and reset as needed Close by pass valve Reprogram the control to the proper regeneration type and frequency Check that the unit is plumbed correctly Line pressure must be at least 20psi Backwash more often Change Media guard Change carbon bed
6. r Reduces Hard Water Scaling Specifications Feedwater Do not use this system on water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Minimum inlet pressure 40 psig Maximum outlet pressure 125 psig Power Voltage 120VAC Frequency 60Hz Power consumption 7 Watts Maximum Installation Minimum ambient temperature 34 degrees F Maximum ambient temperature 122 degrees F Setup Unpacking and Inspection Check the system components for damage or missing parts Where to Install the Filter Consider the following points when determining where to install the water filter e Place the system as close as possible to a sewer drain Runs of up to 12 elevation above the control head is permissible e Do not install the filter where it would block access to the water heater or access to the main water shutoff water meter or electrical panels A 120V electrical outlet is needed to plug in the transformer If the outlet is remote up to 100 feet use 18 gauge wire to connect e Always connect the system to the main water supply pipe before the water heater e Install the system where it will not be subject to temperatures outside of the limits stated in the Specification section or to direct sunlight Installation 1 Determine installation site and locate water main 2 Turn off the water supply to pipes to be cut and drain the house water pipes 3

Download Pdf Manuals

image

Related Search

Related Contents

Nuts Grinder - 株式会社エフ・エム・アイ  Hitachi CP-X870 User's Manual  MANUAL DEL USUARIO PROGRAMA: SINTOMAT  Manual de Instalação e Administração  Benutzerhandbuch  Nokia N79 Cell Phone User Manual  Copyright © 2000 por InFocus, Inc. Wilsonville, Oregon, EE.UU  Guía de configuración y de referencia rápida  User Manual    