1.  piercing cutter to work correctly the CO2 cylinder  and automatic       inflation mechanism on automatic models  must be firmly hand tightened onto the    CO2 inflator head     On UML Pro Sensor inflator heads the PFD is fully armed only when all indicator    status windows are green     Step 7  Record Service Inspection on PFD    7 1 If PFD has passed all applicable self inspection steps 1 through 6 above Sign and date in permanent laundry marker the service  inspection history label located on inflator head side of lung  For a Self inspection prefix the service date by the letters SI to indicate     self inspection     The date format should be kept consistent across the PFDs service inspection history     Step 8  Repack PFD    8 1 Repack PFD and ensure that the manual inflation pull lanyard and knob is not tangled and that it is accessible when PFD is donned     Step 9  Certify the PFD self inspection certificate     9 1 Sign self inspection certificate and record date self inspection was completed   It is also recommended that next inspection due date is noted on the certificate     POWERFLOAT    Your Safety Is Our Business       Under no circumstances must you attempt any repairs yourself     i Last service date  Serial   PI No    date of purchase if 1st service     Inflator head brand      type  manual or automatic     PFD Model       STEP 1  GENERAL INSPECTION RESULT    1 1 EXTERNAL INSPECTION  cover   closures  straps  stitching  fastenings  adjustments  buckles     
2. 1 2 INTERNAL INSPECTION  retro reflective tape  lifting becket  whistle  oral tube  light a    STEP 2 INSPECTION OF LUNG AND ORAL VALVE RESULT    2 1 VISUAL INSPECTION OF LUNG    2 2 RESULT OF LUNG LEAKAGE TEST BC  2 3 OPERATION OF ORAL INFLATION TUBE   VALVE BC    STEP 3 EXAMINE OPERATION OF MANUAL INFLATOR RESULT    3 1 OPERATION OF MANUAL INFLATOR VALVE  applicable for all inflator heads   3 2 FIT NEW FIRING INDICATOR CLIP Ce    STEP 4  INSPECTION AND REARMING OF AUTOMATIC VALVE  automatic inflation models only   ma Date RESULT    E E T  STEP 5 INSPECTION OF CO2 CYLINDER RESULT   52 coz CYuNDENISUNPERCED ANDFREE rrom pamase muson comnosons     53 wach wo recono weer rozon jann  e    STEP 6  REFIT CO2 CYLINDER RESULT    on conen nspecron seso somero OS   anew on NEPECTED tar siap 33 Coz GULNDER AITEDTO waoane OO   OOOO    RESULT    STEP 7  SIGN AND DATE SERVICE INSPECTION SCHEDULE ON PFD  STEP 8  REPACK PFD ACCORDING TO PFD OWNERS MANUAL pC         NEXT INSPECTION DUE                      SIGNATURE        PLEASE RETAIN COMPLETED DOCUMENT UNTIL NEXT SERVICE INSPECTION    
3. 9  C          Step 5  Inspection of CO2 cylinder        33 GRAMS    MIN GR WT   139 0G       Max     2 0 g    V    OK        Oo 2 O feaa      136  SS    5 1 Check that the size   type of CO2 cylinder is correct for the PFD  The Cylinder size is displayed on the cylinder as well as on the PFD lung adjacent to the CO2 inflator head     A A    5 2 Check that the CO2 cylinder is not damaged  is  free from rust and corrosion and has not been  pierced  Replace any cylinder that is pierced   damaged or exhibiting any signs of rust or corrosion  X v   STOP OR       5 3 If cylinder is serviceable  refer 5 2  weigh the cylinder on kitchen or letter  scales  The cylinders weight should correspond to MIN GR WT engraved on  cylinder     2 g  Record MIN GR WT and actual weight of cylinder on the  inspection certificate         a  If cylinder weight is incorrect or cylinder is in anyway defective it must be      replaced  Any replacement cylinder should be checked in same manner     STOP Dispose of scraped CO2 cylinders immediately     Step 6  Refit CO2 cylinder    6 1 Confirm    a  manual inflator mechanism has passed inspection step 3  b  On automatic models that the automatic valve is armed and has passed    inspection step 4     c  the CO2 cylinder being fitted has passed inspection step 5    6 2 To refit cylinder hold the inflator head firmly and screw the CO2 cylinder  clockwise into top of inflator head  Hand tighten until firm     Do not use any tools or undue force    Note  For the
4. Your Safety ls Our Business    INSTRUCTIONS FOR ANNUAL SELF INSPECTION    Applicable for PFDs in recreational use only  for PFD s in commercial use inspections should only be performed by an accredited agent     Before you start    1  Carefully read over all the instructions below   2  Ensure you have spare parts for your PFD  On inflator heads that use a green indicator clip to retain the manual firing lever  the clip will  be broken during inspection  Ensure you have spare clips before you begin inspection    You may also need to replace the CO2 cylinder and on automatic models the cartridge bobbin  All these parts can be purchased through  the retailer or manufacturer    3  Ensure you have access to accurate kitchen or letter scales for checking the weight of the CO2 cylinder    4  Print a copy of the Inflatable PFD self inspection certificate for every PFD being inspected   5  Record on the certificate the PFDs serial PI number  model no   inflator head brand   type  manual or automatic  and last service date        Record each inspection step as it is completed with a Pass  Fail or NA in check boxes provided on the certificate  If the PFD or a  component fails any inspection step 1 through 6  the PFD or faulty component must be replaced before using the PFD  alternatively send the  PFD to an accredited service agent for further test     Under no circumstances must you attempt any repairs  these must only be conducted by trained service personnel     Step 1  General inspe
5. action     Halkey  Roberts       United Moulders       Fit new indicator clip ref 3 2       Step 4  Inspection and rearming automatic valve  automatic inflation models only     The automatic activation mechanism  Cartridge or bobbin as applicable  must be replaced if it has been immersed in water  is past its  expiry date or if the expiry date falls before the PFDs next scheduled service     Do not refit a Co2 cylinder unless the automatic valve is correctly armed     4 1 For models using United Molders automatic inflators fitted with water sensing cartridge  Fig 1    a  Unscrew the cartridge anti clockwise    On models fitted with UML Pro Sensor inflator head the automatic indicator status  bottom window   should be red when the water sensing cartridge has been removed or activated  The Pro Sensor  automatic indicator window should only show green when an armed cartridge is correctly fitted    b  Check that the cartridge is clean and completely dry   c  Record the expiry   replace by dates printed on cartridge on the service inspection certificate and  check the green indicator status disc at base of cartridge is visible  Discard and replace with new  cartridge if expiry   replace by date falls before next service due date or the green status indicator  disc at the base of cartridge is not visible   d  Rearm by screwing cartridge clockwise onto base of inflator head  Tighten firmly by light hand  force only  use no tools  Ensure thread is not obstructed and that green automa
6. ction    1 1 External Inspection   Check   a  Cover has no excessive wear or visible damage    b  All cover closures  hook and loop  zippers etc  are serviceable    c  There is no visible damage or wear to any straps or stitching    d  All fastenings  adjustments and buckles are operating correctly    e  Safety lanyard attachment ring  when fitted  is not worn or damaged     1 2 Internal Inspection   Open cover and check   a  retro reflective tape is firmly attached and not damaged    b  Lifting becket webbing and stitching is not worn or damaged    c  Whistle operation  blow to check operation  and that whistle is securely attached              d  Oral inflation tube has no visible signs of damage   e  If fitted with emergency light check lights expiry date  replace if expired      Step 2  Inspection of lung and oral valve    2 1 Check lung has no signs of excessive abrasion or wear   Pay extra attention to the folds and areas around inflation systems       2 2 a  Remove Co2 cylinder from the inflator head by unscrewing the cylinder anti clockwise    On models fitted with a UML Pro Sensor inflator head check that the manual indicator status  top  window  is red once cylinder has been removed  The Pro Sensor manual indicator status window  should only show green when an unpierced CO2 cylinder is fitted correctly  12h       b  Inflate lung using the oral inflation tube    c  Leave lung inflated with oral tube cap off in a room with a  stable temperature of around 20  C for at 
7. least 12 hours   temperature changes will affect lung pressure    d  After 12 hours check there is no loss of pressure and no visible  damage to lung  If lung is damaged or pressure falls the PFD  must be replaced or sent to an accredited service station for  further tests  Under no circumstances should you attempt to  V repair the PFD yourself       2 3 Deflate inflatable lung checking operation of oral inflation valve  Only deflate lung by  inverting the oral tube cap and gently pressing the top of the inverted cap down into tube    Do not put anything other than the inverted cap into the oral inflation tube  foreign  objects may damage the oral valve    When the lung is fully deflated fit the oral tube cap back into its normal position        OK    Step 3  Examine operation of manual inflator  applicable for all inflator heads     3 1 With CO2 cylinder removed pull manual firing lanyard down sharply to ensure lever moves freely and that the piercing cutter becomes  proud of the sealing washer at base of the upper threaded section  On inflator heads where the lever is secured by a green indicator clip  this action will break the indicator clip  If lever movers freely and piercing cutter becomes proud fold lever back up into normal position     3 2 On inflator heads that use an indicator clip to secure the lever  fit a new green indicator clip now     If the manual inflator does not operate properly the PFD must be replaced or sent to an accredited service agent for further 
8. tic status indicators    are visible    Seoate0s09 Men V X    Na   OK         03   MAR  09   2009 JAN FEB MAR APR       Fig 1 UML water sensing cartridge       4 2 For models using Halkey Roberts automatic inflator with transparent head and water   sensing bobbin  Fig 2      a  Check green indicator is showing at base of the transparent head  If indicator is showing red   the water sensing bobbin has been activated and should be replaced    b  Remove water sensing bobbin by unscrewing transparent head anti clockwise    The Halkey Roberts water sensing bobbin has a 4 year expiry and is printed with the date of   manufacture  Month  Day  and Year   Calculate when bobbin replacement is due by adding 4   years onto date of manufacture  Discard and replace bobbin if indicator at base of transparent   head is red  refer 5 2 a  or the bobbin expiry date falls before the PFDs next service due date    c  Record the bobbin expiry   replacement date on service inspection certificate   d  Rearm automatic firing mechanism by fitting the bobbin onto base of the inflator head  white   i oe ae inflator with transparenthead side facing away from head  and reinstalling the transparent head  screw clockwise by light  hand force until tight   Ensure thread is not obstructed and automatic status indicator at base of  transparent head is green     e  TEE a E ees ame E MAX 2010   19  2005 2006 2007 2008 2009 2010 A V   x          gt   06  4  2010  JAN FEB MAR                   SB 1  S HR    APR    
    