Home

P-Series Manual.pub

image

Contents

1. 00 to 99 When 99 is reached display will reset to 1 and begin cycling on its own Switch power OFF and then ON Now all parameters are reset to factory settings and system is in Normal Mode CLEANING POWER BASE WARNING MAINTENANCE and SERVICE Edhard Power Bases are designed to be maintenance free If in time your Power Base should require service In North America Package the machine carefully in a box with adequate cushioning Attach a note detailing the problem with the unit your name company name address and phone number Ship the unit to Edhard Corp 279 Blau Road Hackettstown NJ 07840 Usual turnaround time is 24 hrs from receipt of unit Outside North America Contact your dealer AM DO NOT PLACE POWER BASE IN WATER OR ANY OTHER LIQUID MDO NOT SPRAY POWER BASE WITH WATER MDO NOT CLEAN POWER BASE WITH SOLVENTS OR CHEMICALS A UNPLUG POWER BASE BEFORE CLEANING CLEAN EXTERIOR USING A DAMP CLOTH ONLY AM MAKE SURE THAT YOUR PUMP FILLER UNIT IS PROPERLY MAINTAINED THIS IS ESSENTIAL TO KEEPING YOUR POWER BASE RUNNING CLEANLY AND EFFICIENTLY One Year Limited Warranty Edhard Corp warrants that the Power Base will be free from defects in material and workmanship for the period of one 1 year from the date of purchase This warranty is limited to the original user and is not transferable Warranty is void if the unit has been damaged by accident unreasonable use negl
2. Base While eliminate dripping pressed changes to parameters will holding F U down and against back of not be allowed and the system will pump well press SE to engage drive INSTRUCTIONS TO CHANGE return to its prior mode Normal 5 Place product in hopper To insure PARAMETERS Automatic Continuous consistent dosing make sure product is Step D Press one of the following keys to free from lumps and air pockets The following 4 steps will allow access to access desired parameter 6 To prime pump press PR then press any one of the 5 changeable parameters Key 1 Reverse and hold Trip Arm until product has begun NOTE Steps A D must be repeated to Key 2 Resolution to exit the Spouts Release Trip Arm access each separate parameter Key 3 Automatic Cycling 7 To set amount to be dispensed enter a Key 4 Continuous two 2 digit number ex 07 25 Amount Step A Switch power OFF Press and hold Key 5 Reset can be changed by keying in a new two 9 and switch power ON Display will digit number show 11 Edhard Corp 279 Blau Road Hackettstown NJ 07840 USA Tel 908 850 8444 Fax 908 850 8445 Toll Free in USA 888 edhard 1 e www edhard com cdhord REVERSE Enter the desired reverse value from 1 99 Enter 0 for no reverse Press PR to enter your selection in memory Press SE to return to prior mode RESOLUTION Enter the desired resolution value from 1 99 Press PR to enter
3. selection in memory Press SE to return to your prior mode AUTOMATIG CYCLING Press 3 to toggle between ON 1 and OFF 0 Dispensing and waiting times must both be entered for this mode to function Dispensing time Press 3 to display 1 ON and press PR Enter desired dispensing time from 1 99 and press PR Display will switch to waiting time Waiting Time Enter desired waiting time from 1 99 and press PR Display will switch to dispensing time number and it will be blinking To begin cycling press trip arm Press again to stop To change dispensing time Stop cycling Enter a new dispensing time Press trip arm to begin cycling To change waiting time Stop cycling Press PR and enter a new waiting time Press PR and dispensing time will be blinking Press trip arm to begin cycling To exit automatic cycling Follow Steps A D Press 4 to display O OFF Press PR to resume normal mode CONTINUOUS DISPENSING Press 4 to switch this mode between 1 ON or O OFF Press 4 to display 1 and then press PR Display will now show CC Press trip arm and hold to dispense Release trip arm stop dispensing To exit continuous mode Follow steps A D Press 4 to display 0 Press PR unit will return to normal cycle mode TEST MODE RESET PARAMETERS TO FACTORY SETTINGS Press 5 and display will step through all numbers from
4. 8 850 8444 Fax 908 850 8445 Toll Free in USA 888 edhard 1 e www edhard com cdhard Edhard Corp 219 Blau Road Hackettstown NJ 07840 USA Tel 908 850 8444 Fax 908 850 8445 Toll Free in USA 888 edhard 1 www edhard com
5. BRN BRN ee KEYPAD 1234 z GREEN IND Brake L 6 oe ___ BLACK or RED 0 o o o o BLK BLACK or RED w 1 OO 1 BLK N X TA o VIOLET VIO RED JP1 O 0 Io BLUE BLACK ORANGE ae Timer Board WHITE Capacitor Edhard Corp 279 Blau Road Hackettstown NJ 07840 USA Tel 908 850 8444 Fax 908 850 8445 Toll Free in USA 888 edhard 1 e www edhard com cdhord WIRING DIAGRAM MODELS MKS GREEN GREEN il Fan On Off Switch H L ta 2 2 ND D O D Receptacle A C Power Input BROWN Remote Trigger BROWN BROWN BROWN BLACK OR OR KEYPAD VIOLET Timer Board TTT BLACK O l JJ gt Z Q m O QD OD QD Q a DE WHITE Edhard Corp 279 Blau Road Hackettstown NJ 07840 USA Tel 908 850 8444 Fax 908 850 8445 Toll Free in USA 888 edhard 1 e www edhard com cdhord IMPORTANT INFORMATION In need of assistance Please give us a call In the US 888 edhard 1 888 334 2731 Elsewhere 908 850 8444 7 00am 3 30pm EST e mail us tech edhard com Please make sure to provide the ownership information you have recorded at left Important Ownership Information Please fill out and retain for your records Model Serial No Date Purchased Purchased from Use this table to record settings for your most freguently used products Edhard Corp 279 Blau Road Hackettstown NJ 07840 USA Tel 90
6. L INSTRUCTIONS BEFORE OPERATING THIS EQUIPMENT TO PROTECT AGAINST RISK OF ELECTRICAL SHOCK DO NOT PUT POWER BASE IN OR SPRAY WITH WATER OR OTHER LIQUID UNPLUG POWER BASE FROM ELECTRICAL OUTLET WHEN CLEANING KEEP HANDS AND FOREIGN OBJECTS OUT OF PUMP INLET AND OUTLET TO AVOID PERSONAL INJURY AND OR DAMAGE TO EQUIPMENT DO NOT OPERATE POWER BASE WITH DAMAGED POWER CORD OR PLUG OR AFTER UNIT HAS BEEN DROPPED OR DAMAGED IN ANY MANNER DO NOT USE AN EXTENSION CORD WITH THIS UNIT SUCH USE MAY RESULT IN FIRE ELECTRICAL SHOCK OR OTHER PERSONAL INJURY NOTICE USER ASSUMES ALL RESPONSIBILITY FOR SAFETY AND ANY USE NOT IN ACCORDANCE WITH THESE INSTRUCTIONS FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN FIRE ELECTRICAL SHOCK OR OTHER PERSONAL INJURY OPERATING INSTRUCTIONS NOTE Amount setting is retained in Step B Within 1 5 seconds press PR Power Base memory when unit is display will show riri If PR is not 1 Plug line cord into a GROUNDED switched OFF only after at least one cycle pressed within 1 5 seconds changes electrical outlet has run to parameters will not be allowed and 2 Insert spouts in Filler Unit F U and turn 8 To begin dispensing press Trip Arm system will return to prior mode to lock in place NOTE A slight reverse motion is Normal Automatic or Continuous 3 Switch power ON programmed into Power Base This helps Step C Press 8 If any other key is 4 Place F U onto Power
7. OPERATING AND SERVICE MANUAL MODELS MK MKH MKS HE Bis aaa GC Cal ER lt gt MABE eg adhard anten moon t Edhard Corp 279 Blau Road Hackettstown NJ 07840 USA Tel 908 850 8444 Fax 908 850 8445 Toll Free in USA 888 edhard 1 e www edhard com cdhord Thank you ICR We at Edhard Corp would like to take this opportunity to thank you for your purchase We realize you always have a choice and we will strive to remain yours Our commitment to you is to provide customer service and technical assistance that equals the quality of our products With the proper care and minimal maintenance your Edhard Powerbase will provide years of valuable service If you should have any questions concerns or problems please do not hesitate to call or write us we will do our best to help Toll free 888 edhard 1 888 334 2731 in US Phone 908 850 8444 Fax 908 850 8445 E mail meter edhard com for sales help tech edhard com for technical concerns Again we thank you for your purchase Edhard Corp 279 Blau Road Hackettstown NJ 07840 USA Tel 908 850 8444 Fax 908 850 8445 Toll Free in USA 888 edhard 1 e www edhard com cdhord IMPORTANT SAFETY INSTRUCTIONS AA PERSONAL INJURY PRODUCT DAMAGE HAZARD TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK PERSONAL INJURY OR PRODUCT DAMAGE WHEN USING THIS EQUIPMENT FOLLOW BASIC PRECAUTIONS INCLUDING THE FOLLOWING 1 2 READ AL
8. P 3333 P 3333 Screw A 1 ech a Ne 0 ess M sch eck 1 sch P 2186 P 2186 P 2186 Screw O P 2115 P 2115 P 2115 Base Assembly Model MK Ref No Description Qty Part Number Brake Assembly Screw Motor Assembly Motor Bolt Washer Nut Gear amp Idler Assembly Output Gear Assembly Gearbox Cover Screw Capacitor Assembly Screw Base Rubber Foot Assembly esch OSI OT RJOR A N O po M h Ah Ref No Description Brake Assembly Base Assembly Model MKH Part Number for Model MKH 120V 60Hz 220V 50Hz Screw Motor Assembly Motor Bolt Washer Nut Gear amp Idler Assembly ONO OR ON Output Gear Assembly Gearbox Cover O Screw esch Capacitor Assembly NO Screw QD Base h D Rubber Foot Assembly P A Mich D ch M M NNN p Base Assembly Model MKS Part Number for Model Ref No Description Qty MKS 120V 60Hz 220V 50Hz 6 Nit 4 Pei P 2i22 gt 8 Screw 1 3 P 2120 P2120 9 FanAssembly 1 PS 2402 PS 2401 cdhord WIRING DIAGRAM MODELS MK MKH Switch Receptacle Trigger Switch I On Off Switch I A C Power Input Be O D UE H bel O 0 x Z O xX m peee 000000 OR OR
9. ect or improper service or alteration During the above One Year Warranty period a defective unit will be replaced or repaired at the discretion of Edhard Corp The Power Base must be returned freight charges prepaid to Edhard Corp Please register your power base online at www edhard com or send the attached warranty registration card to Edhard Corp Edhard Corp 279 Blau Road Hackettstown NJ 07840 USA Tel 908 850 8444 Fax 908 850 8445 Toll Free in USA 888 edhard 1 e www edhard com EI pl Thumb Screw Power Base Housing Assembly Model MK MKH MKS Part Number for Model d MKH PS 2512 MKS PS 2512 Safety Clamp PS 2511 PS 2511 PS 2511 Screw P 2118 P 2118 P 2118 Pump Driver Assembly P 3029 P 3054 PS 3146 Power Base Housing P 3028 P 3028 PS 3170 Trip Pin P 2046 P 2046 P 2046 Trip Arm Assembly P 3030 P 3030 P 3030 Boot P 2072 P 2072 P 2072 CO 0 N 0 01 BG PO Trigger Switch P 2141 P 2141 P 2141 O Keypad P 2085 P 2085 P 2085 Timer Board 120V P 3700 P 3710 PS 3708 Timer Board 220V N A P 3711 PS 3709 Screw P 2116 P 2116 P 2116 Receptacle Power Cord P 2628 P 2628 P 2628 Fuse P 2601 P 2601 P 2616 On Off Switch P 2142 P 2142 P 2142 Receptacle Footswitch Hose Assy P 3333