1.  overfill  If  the tank does not hold the air then the tank is bad and should be replaced    Production problems    1  Check flow to the membrane housing  Turn off the water at the EZ adapter  and tank  and briefly turn on the RO faucet at the sink to relieve any system pressure  Then  pull the black tube out of the top of the black membrane housing at the quick connect  fitting   There is only one fitting on the top of the membrane housing  the bottom has two    one white  one grey   Point the tube you have just disconnected into a pitcher and turn on  the EZ adapter valve  The water flow from the tube should be fairly strong     Page 9    Customer Service Hotline 1 877 693 PURE    Tap Master Series Reverse Osmosis System   Owners Manual    USING QUICK CONNECT FITTINGS    Insert tube Push up to tube stop    Push in collet and remove tube             Push the tube into the fitting  to the tube stop  The collet  gripper  has To disconnect  ensure the system is depressurized before removing the tube   stainless steel teeth which hold the tube firmly in position while the          ring Push in collet squarely against face of fitting  With the collet held in this  provides a permanent leak proof seal  position  the tube can be removed     Pull to check secure          Pull on the tube to check that it is secure  It is a good practice to test the  system prior to leaving site and or before use     Troubleshooting  IMPORTANT NOTE  Before performing service on the Tap Master RO at a
2. BLUE 3 8    tubing into quick connect faucet adapter  Push tubing all the  way in  then pull back gently to check fit  Most push pull fittings take about a 1   4    of tubing    Page 6    Customer Service Hotline 1 877 693 PURE    Tap Master Series Reverse Osmosis System   Owners Manual    inserted into them     6  Install reserve tank and connect reserve tank tubing     Affix product label to the top  of the reserve tank  Apply included white Teflon pipe tape to 1 4    water stud on top of the  reserve tank  DO NOT touch the air nipple near the bottom of the tank found under a blue cap   Fit the reserve tank shut off valve  see picture below  to the 1 4    water stud   Hand tighten  until it is snug   Over tightening may cause damage  See Fig  11  Insert BLACK 3 8    tubing  into the tank shut off valve  Push tubing all the way in  then pull back gently  to check fit  Most  push pull fittings take about a 2    of tubing inserted into them  Make sure reserve tank shut  off valve is in the closed position  where the blue handle is perpendicular to the body         gt  VIDEO INSTALLATION INSTRUCTIONS AVAILABLE ONLINE  lt        7  Pressurize the Tap Master RO   For Tap Master UV  amp  ULTRA first connect power adapter  to UV filter so the filter glows blue  Audible alert should sound when the connection is not  complete   either not connected to UV filter or UV filter burnt out    Make sure unit is dry  Water should flow normally from your main kitchen faucet  Double  check to 
3. Tap Master Series Reverse Osmosis System   Owners Manual    10 Tips for an Easy and Successful Installation    1  Keep it simple   there are 4 connections to make  and the tubing is color coded   VIDEO INSTRUCTIONS ARE AVAILABLE ONLINE  6 PARTS     2  Have plenty of time  light  space  and towels before getting started  If everything goes well   you should be done in 45 minutes  However  if your feed water line is a different size  or if you  don   t have an extra hole for the faucet  it can take somewhat longer     3  NEVER use plumber   s putty  thread lock  or anything else you wouldn   t eat      any part of  this system  You may use as much white Teflon plumber   s tape as you like  If you use plumber   s  putty on your faucet  you will have disgusting and potentially toxic water for the life of the fau   cet     4  Mount the faucet first  and when making the final connection  use the quick connect faucet  adapter found in the bag of parts with the EZ adapter  tank valve  and drain clamp     5  If you have a 3 hole sink and want to avoid drilling    4  hole for the RO faucet  then get a  single handle kitchen faucet  This will free up 2 holes  one of which you may use for the RO fau   cet  the other you can use for a soap dispenser or side sprayer     Tap Master    6  Mount the Tap Master vertically so that the back cap is on top  There is only one    black cap    Tap Master Artesian Full Contact    and it has one grey fitting at its top  Mount the  optional  permeate pu
4. base cover plate with marker  See Fig 2  Place towel  underneath sink  below drilling site  to collect fillings  Always wear protective eyewear and gear  while drilling  and while under sink    2  Using        masonry bit and variable speed corded power drill  slowly begin drilling through the  porcelain  Drill bit should be perpendicular to sink  Failure to do so may cause the drill bit to slip  and cause bodily injury  and or property damage  Rinse  amp  dry drill bit tip and sink area with cool  water for every 20 seconds of drilling to prevent drill bit overheating and sink damage  Small  localized flaking or chipping may occur  Use caution   drill bit may be very hot  DO NOT    Page 4  Customer Service Hotline 1 877 693 PURE    Tap Master Series Reverse Osmosis System   Owners Manual    No water or ice from refrigerator water center Make sure line from Tap Master RO to  refrigerator has pressure  Make sure refrigerator water center and or icemaker are turned ON   and refrigerator is plugged in  If water center works  but icemaker does not  then defrost the  freezer as the line may have frozen     Hissing or flowing sounds from Tap Master RO are normal during the water purification process   Sounds should last for approximately 1 hour per gallon of water used  Sounds should stop once  the reserve tank is full  Permeate pump equipped systems will    click    and    whoosh        Air Bubbles  tiny air bubbles often accompany a new system installation and filter  changes  Ai
5. damaged  while rolling the refrigerator  Trim extra tubing  Make sure the cut is straight  the edge is  completely smooth  and the tube is rounded  A scratched  gouged  damaged  or oblong end  will leak  Connect the female metal fitting from the refrigerator kit to the male metal fitting  on the refrigerator  See Fig  14  Make sure all male metal fittings are thoroughly Teflon taped  to prevent leaks  Do not roll back refrigerator until the Tap Master is fully installed and  operational  Make sure shut off valve on the refrigerator connection kit at the Tap Master is in  the OFF position  where the blue handle will be perpendicular to the body     4  Mount the Tap Master   Identify location for installing mounting clips for the Tap Master  RO unit  Location should allow room for the reserve tank  for connecting and disconnecting  the unit  and enough room for performing general service on the unit  Typical locations are on  either right or left side  near the back wall  Use supplied mounting clips and mounting  template located inside back cover  Tap Master should be mounted vertically where the drain  line out is on the bottom of the Tap Master  See Fig 8  amp  12  Insert ORANGE 1 4    tubing into  EZ adapter used in step 1    VIDEO INSTALLATION INSTRUCTIONS AVAILABLE ONLINE    5  Install water out line to RO faucet     Screw quick connect faucet adapter onto the  bottom of the RO faucet threaded shank until it is snug  See Fig  15  Over tightening may  cause damage  Insert 
6. enough space to mount the drain saddle clamp  See Fig  8  amp  Fig  10  Drainpipe material can be  either metal or plastic  Locate drain hole template supplied with drain saddle clamp  and peel  off its backing  Place the template on the previously identified location of drainpipe for the  drain saddle clamp  Place 1   4    drill bit inside template hole  and drill a hole into the drainpipe   Drill through one side only  DO NOT drill a hole clean through both sides of the drainpipe  This  will result in a leak  and require replacement of that piece of drainpipe  Mount the drain saddle  clamp on top of the template with the holes aligned  You may use a screwdriver to align the  holes  Fit drain saddle clamp back plate and screws  Alternate tightening screws on each side  of the drain saddle clamp to ensure an even  snug fit  See Fig  10  Locate RED 1 4    drain  tubing and push on black plastic nut found in drain saddle bag  Hand tighten black plastic nut    Page 5    Customer Service Hotline 1 877 693 PURE    Tap Master Series Reverse Osmosis System   Owners Manual    onto the drain saddle male fitting until it is snug  Wrap excess tubing around the drainpipe     2a  Mounting Permeate Pump  optional    Mount permeate pump side by side with the  tap master using supplied mounting clip and screws  IMPORTANT  permeate pump must  be mounted with indicator arrow pointing up  Indicator arrow is the large  center  arrow  See page 10 for mounting orientation diagram     3  Install re
7. er  50 60Hz  110   240v  featuring audible alert    Flow restriction architecture  integrated flow restrictor and water check valve   central auto shut off valve    Drain saddle  all fittings and connecting hardware    Reserve tank  3 2 gallon  or 9 gal upgrade    stand  quick connect ball valve  Chrome long reach sink faucet  or custom faucet   quick connect fitting and  hardware    EZ adapter   feed water adapter 3 8    mc x 3 8    fc x 1 4    tube    Maintenance Schedule    Sediment filter annual replacement  Carbon filter s  annual replacement  IRON carbon filtert 6 month replacement  UV filter  annual replacement  Membrane  50 gpd TFM  4 5 year replacement  Artesian filter annual replacement    General System Specifications   Feed water  PSI 40   100 PSI   Feed water Temperature  40     100   F    Max  Total Dissolved Solids  TDS   2000 ppm  Max  Hardness  10 gpg   DH limits  4   10    1 Included with Tap Master IRON and ULTRA only  4 Included with Tap Master Artesian only   2 Included with Tap Master standard and UV only   3 Included with Tap Master UV and ULTRA only     Page 3    Customer Service Hotline 1 877 693 PURE    Tap Master Series Reverse Osmosis System   Owners Manual    System Location  The Tap Master may be installed under a sink  or in a basement within 20    feet of the RO sink  faucet as long as the Tap Master is not subjected to freezing temperatures  The Tap Master    Should be mounted vertically where the drain line out is at the bottom  Mount the res
8. er Service Hotline 1 877 693 PURE Customer Service Hotline 1 877 693 PURE    Tap Master Series Reverse Osmosis System   Owners Manual    ALLOW    CLEARANCE FROM TOP            _ Mounted RO sink spigot                    0 2         02   42        amsav             Page 2    ALLOW    CLEARANCE FROM BOTTOM    Page 11  Customer Service Hotline 1 877 693 PURE    Customer 5       Tap Master Series Reverse Osmosis System   Owners Manual    2  If the flow to the membrane housing is strong  then check the water flow exiting the  white fitting at the bottom of the membrane housing  The water flow from the tube  Should be a thin  but steady trickle  If not  then the membrane is plugged and should be  replaced  Please note that the minimum water pressure for the system to operate is 40psi   3  If the flow to the membrane housing is weak  then start working your way backward and  check each connection point until you find the blockage point  At each point   turn off the  water at the EZ adapter and tank  and briefly turn on the RO faucet at the sink to relieve  any system pressure  Disconnect the tube from the fitting  Point the tube you have just  disconnected into a pitcher and turn on the EZ adapter valve     Discoloration of water The first batch of water produced from your purification  system may be discolored due to the presence of carbon from the carbon filters  and  a small amount of preservative  This is normal  DO NOT drink the first 6 5 gallons of  water  Drinking from un flu
9. erve tank on    a sturdy shelf  because it will weigh over thirty pounds when full     Tools Required   Safety glasses   Towels   Phillips screwdriver   Scissors   Medium Crescent wrench   Medium pliers   Felt tip pen or marker   Variable speed corded power drill  3 8    for the sink hole  14    for the remainder   14  metal drill bit w  cobalt tip   1  metal drill bit w  cobalt tip  not required if sink has a pre drilled hole    1  masonry drill bit  not required if sink has    pre drilled hole  or if sink is not porcelain     VIDEO INSTALLATION INSTRUCTIONS AVAILABLE ONLINE    www theperfectwater com Installation Instructions html    TUBING COLOR CODING  ORANGE   LINE IN BLACK   TO STORAGE TANK  RED   TO DRAIN BLUE   TO RO FAUCET    Drilling hole for RO faucet   porcelain sinks steps 1 5  stainless sinks steps 3 5  WARNING  Serious cracking and damage may occur to your sink even if instructions are followed  exactly due to age and the imperfections inherent in natural materials  Instructions may not  apply exactly to your sink  Use caution   sink may be slippery     1  Remove base cover plate from RO faucet packaging  Line up base cover plate with other sink  faucets  See Fig 1  Check underside of sink for spacing from trim  curvatures  and other  obstacles  See Fig  15  Don   t place spigot too close to obstacles   leave yourself enough room  under the sink to use hand tools  Either right or left side of the sink is OK provided previous  conditions are met  Mark center of 
10. frigerator kit  optional      Installation may vary according to make  model   and age of your refrigerator  Make sure refrigerator icemaker and water center are turned  OFF  Clean area below and around refrigerator thoroughly  Use care when rolling out  refrigerator  Flooring may become scratched  gouged or damaged from moving refrigerator   Consult your local licensed contractor or plumber for trimmed in refrigerators  or refrigerators  without rollers  Roll out refrigerator  Unplug refrigerator electric plug  Locate water line in for  refrigerator   Yours may already be connected to a water line from wall  If so use local angle   stop to shut off water  Disconnect female fitting  See Fig  13   Plan the route for the water  line from the Tap Master  Drill 14    holes through the lower cabinetry  high along the back wall  just below the drawers  See Fig  9  Make sure cabinet contents are removed  prior to drilling   and 1   4    tubing does not come into contact with drawers  doors  or sharp objects  Smooth the  holes free from splinters and sharp edges   Alternate route for refrigerator line    run        refrigerator tubing along the baseboard  and enter the kitchen sink cabinet by drilling a        opening in the bottom board of your kitchen sink cabinet  towards the front baseboard   Push  tubing through the cabinetry holes from the Tap Master RO to refrigerator  Allow 2 4    of extra  tubing at the refrigerator  and position it so that it cannot be crushed or otherwise 
11. ing  Push tubing all the way  in  then pull back gently  to check fit  Most push pull fittings take about a 1 3    of tubing  inserted into them     Page 8    Customer Service Hotline 1 877 693 PURE    Tap Master Series Reverse Osmosis System   Owners Manual    touch drill bit  Electrical hazard  DO NOT allow power drill electrical components to  come into contact with water  Use caution     sink may be slippery    3  When metal is struck  switch to  4    metal bit with cobalt tip  Drill bit should be  perpendicular to sink  Failure to do so may cause the drill bit to slip and cause bodily injury   and or property damage  Begin drilling to drill a hole all the way through the sink  Rinse  amp  dry  drill bit tip and sink area with cool water for every 20 seconds of drilling to prevent drill bit  overheating and sink damage  Small localized flaking or chipping may occur    4  When 1   4    hole is completely drilled through  switch to 2    metal drill bit w  cobalt tip  Drill  bit should be perpendicular to sink  Failure to do so may cause the drill bit to slip and cause  bodily injury  and or property damage  Begin drilling to enlarge the 1   4    hole to      all the way  through the sink  Use caution when hole is near completion to avoid damaging sink surface   Rinse  amp  dry drill bit tip and sink area with cool water for every 20 seconds of drilling to  prevent drill bit overheating and sink damage  Small localized flaking or chipping may occur    5  When    gt     hole 
12. is drilled through completely  install RO faucet with provided mounting  hardware  For more details  see mounting instructions enclosed with hardware  See Fig  3   Connect Tap Master to RO faucet using Quick connect faucet adapter as outlined later     Installing The Tap Master Reverse Osmosis System  A  RO Faucet   Mount faucet according to the installation instructions enclosed with faucet    packaging     1  Install EZ adapter on cold water line   Always wear protective eyewear while under  sink  Locate the cold angle stop  the main water lines under the sink     one hot water  one cold  water   and turn clock wise to shut off the water  See Fig  4  Locate 3 8    fitting  typically  found on the line out of the angle stop  see Fig 7  or where the existing line connects to the  kitchen faucet  See fig  6  Disconnect the 3 8    fitting on either the angle stop or the kitchen  faucet  Use Teflon tape on the EZ adapter and the angle stop male threads  and make sure o   rings are properly seated  Fit the EZ adapter and tighten  Check for water pressure  amp  leaks on  ball valve  Turn ON water by rotating angle stop counter clockwise  Close ball valve  by  turning the handle perpendicular to the ball valve body   Valve is closed in Fig  7  Have a bowl       cup nearby to catch water  Dry all parts  check for leaks  and snugness     VIDEO INSTALLATION INSTRUCTIONS AVAILABLE ONLINE    2  Install drain saddle clamp and drain line     Identify a vertical section of drainpipe with  
13. make sure all valves are in the closed position  except for the main angle stop valve   which should be open  SLOWLY open the EZ adapter ball valve  You should hear water rushing  through the system  Open the RO faucet to by flipping the lever up  where it should stay open   A trickle of water should be present after 2 20 minutes  Some blackening of the water may  present due to loose carbon being flushed out  Close the lever on the RO faucet after the  trickle runs clear  and allow the system to pressurize  When the system has pressurized and  Shut off   check for leaks  Then open the reserve tank valve slowly  Allow reserve tank to fill  for 2 5 hours  and then drain completely  You will drain the tank by opening the RO faucet  Let  run until trickle present again  Close Ro faucet  Let refill and repeat  System must be flushed  at least twice prior to use   OPTIONAL Plug in refrigerator electric plug  open refrigerator line  ball valve so that the blue handle is parallel with the white body  Make sure refrigerator  icemaker and water center are turned ON  Check for leaks  Check for pressure at the  refrigerator   s water center  Dispose of the first two batches of ice after installing the Tap  Master RO  Use caution when rolling refrigerator back into place  DO NOT crimp or crush  water line  as a leak will likely develop   IMPORTANT   After reserve tank has filled  2 5  hours   Drain entire reserve tank completely  until the flow from the RO faucet falls  to a thin steady 
14. mp correctly nothing will    work  There is a big arrow on the permeate pump  make sure it points up  Tap Master IRON  7  Mount the drain saddle on a vertical section of drain pipe  IF you have to mount the drain Tap Master UV  saddle on a horizontal section  then drill the hole on the top side of the pipe or at least at an an  T Mast ULTRA  gle where the drain water from the Tap Master drops down into the drain pipe   Think of a man       Master    hole passage into the sewer  When making the connection from the system to the drain saddle    wrap the tubing around the drain pipe a few times  so that some loops of tubing are higher than  the fitting     8  DO NOT touch the air nipple on the side of the reserve tank  You may be tempted to check  the pressure  or pump it up     don   t  It already has plenty of air  Adding more will not boost flow   it will only decrease tank capacity         Read the instructions thoroughly before beginning  There is allot of information there  some  of which you may not need for your application  If you have questions   call or email  Email will  usually be answered within hours even at night     10  Have patience  Your new Tap Master may take some time to break in and start flowing   Make sure you fill  and drain  the reserve tank at least twice     TUBING COLOR CODING  ORANGE   LINE IN BLACK   TO STORAGE TANK  RED    TO DRAIN BLUE   TO RO FAUCET       Perfect Water Technologies  Inc   Copyright    2010    PERFECT WATER     Page 12    Custom
15. ny time  and for  any reason  first close all under sink water valves  except for the RO faucet which you  Should open to relieve system pressure and drain away excess water from the lines  Push   pull and quick connect fittings are nearly impossible to remove when under pressure     Leaks from metal fittings Unscrew fittings and re tape male fitting  Tape should be wound 5   7 times around male thread  Tape should not cover opening  Use only Teflon tape  Re   tighten fitting securely  Over tightening can crush the tubing insert and cause a water  blockage     Leaks from plastic fittings Plastic fittings should be firmly finger tightened  Under tightening  can result in leaks  over tightening can crush the tubing and result in a water blockage   For plastic fittings only  make sure the plastic tubing has an insert in the tube end  anda  feral  o ring which compresses the tubing around the insert  in the plastic female fitting   Drain tubing does not need an insert     Leaks from push pull or quick connect fittings Disconnect fitting by depressing the collet  ring on the fitting with one hand and pulling out the tubing with the other hand while the    collet ring is still depressed  Tubing cannot be pulled out without depressing the collet ring   and relieving system pressure  Make sure the tubing is cut is straight  the edge is  completely smooth  and the tube is rounded  Scratched  gouged  damaged  or oblong  tubing end will leak  Re insert the tubing into the push pull fitt
16. r becomes trapped inside the tiny carbon pores and is released over time   not gallons  After pouring a glass of water  allow a few seconds for the water to clear   Enjoy     Weak pressure at RO sink faucet  amp  Reserve tank filling slowly  NOTE  Seasonal changes in temperature can cause pressure imbalances within the system    resulting in slow water production  Oftentimes the imbalance will correct itself on its own within  a few days  You may also restore the internal system pressure balance by draining the tank   unplugging the tubing from the tank  then allow the system to stand open overnight  Turn it  back on  and allow the tank to refill     Weak pressure is either a storage problem or a production problem  To determine which close  the tank valve and open the RO faucet  You should see a constant trickle of water  If this is  what you see then it   s a storage tank problem  If you see zero water  dribbles out  or a few  drops only then it   s a production problem     Storage tank problems     1  Make sure storage tank is full  and has been flushed at least twice  6 5 gallons     2  Make sure the angle stop is wide open    3  Check all tubing for kinks or sharp bends   this can impede the flow of  water    4  Check reserve tank air pressure with tank empty  system off and faucet open  Air valve is  located on the side of the tank under a cap Use a bicycle tire pressure gauge  Tank should  have 7 5 psi  If the pressure is less  then add air using a bicycle pump  Do not
17. shed system may cause gastrointestinal discomfort   colic and or diarrhea  Consult a physician if discomfort persists  Running out the  first two tanks will effectively flush out the system  and make it ready for use  The  tank is full when the hissing or clicking stops     Permeate pump should be mounted with inlet and outlet ports to the sides  and the  center indicating arrow pointing up     MOUNTING ORIENTATION       CORRECT INCORRECT    Page 10    Customer Service Hotline 1 877 693 PURE    Tap Master Series Reverse Osmosis System   Owners Manual    Tap Master Contents     Instruction book  detailed descriptions  photos and troubleshooting guide    10    Sediment pre filter  5 micron bonded spun poly with high holding depth  1   year service life    10    IRON Carbon pre filter     5 micron granular activated carbon  coconut shell  carbon  with IRON filtration  6 month or 1500 gallon service life    10    Carbon pre filter   5 micron granular activated carbon  coconut shell carbon    1 year or 3900 gallon service life    10    Carbon post filter  5 micron granular activated carbon  coconut shell carbon    1 year or 3900 gallon service life    10    Artesian post filter   5 micron granular activated carbon  coconut shell  carbon  with advanced remineralization media  1 year or 2500 gallon service life   Thin Film Composite membrane 0 001 micron ultra fine pore  50 gallon per day  4   5 year service life    UV filter  1 year service life  with universal electronic transform
18. trickle  Repeat  Reserve tank is full when the hissing or clicking  noise stops  Discoloration of water may be present  System must be flushed twice  prior to use  Allow another 3 hours for the reserve tank to refill        Faucet Adapter EZ Adapter Tank Shut off Valve    Page 7    Customer Service Hotline 1 877 693 PURE    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Computer Gear 26-0100MM  Q24 User Manual - Galileo Equipments  Sky02 3D Goggles User Manual Here  Simulateur de logidules    Película de Protecção ScotchcalTM 3647  Commands - Flint Machine Tools, Inc.  MANUAL DE INSTALACIÓN PISO WPC  Smeg-PLA6045X - Instructions Manuals  Equip 24-Port Keystone Cat.6A Unshielded Patch Panel    Copyright © All rights reserved. 