Home

TMAFC Installation and Service Manual

image

Contents

1. overfill If the tank does not hold the air then the tank is bad and should be replaced Production problems 1 Check flow to the membrane housing Turn off the water at the EZ adapter and tank and briefly turn on the RO faucet at the sink to relieve any system pressure Then pull the black tube out of the top of the black membrane housing at the quick connect fitting There is only one fitting on the top of the membrane housing the bottom has two one white one grey Point the tube you have just disconnected into a pitcher and turn on the EZ adapter valve The water flow from the tube should be fairly strong Page 9 Customer Service Hotline 1 877 693 PURE Tap Master Series Reverse Osmosis System Owners Manual USING QUICK CONNECT FITTINGS Insert tube Push up to tube stop Push in collet and remove tube Push the tube into the fitting to the tube stop The collet gripper has To disconnect ensure the system is depressurized before removing the tube stainless steel teeth which hold the tube firmly in position while the ring Push in collet squarely against face of fitting With the collet held in this provides a permanent leak proof seal position the tube can be removed Pull to check secure Pull on the tube to check that it is secure It is a good practice to test the system prior to leaving site and or before use Troubleshooting IMPORTANT NOTE Before performing service on the Tap Master RO at a
2. BLUE 3 8 tubing into quick connect faucet adapter Push tubing all the way in then pull back gently to check fit Most push pull fittings take about a 1 4 of tubing Page 6 Customer Service Hotline 1 877 693 PURE Tap Master Series Reverse Osmosis System Owners Manual inserted into them 6 Install reserve tank and connect reserve tank tubing Affix product label to the top of the reserve tank Apply included white Teflon pipe tape to 1 4 water stud on top of the reserve tank DO NOT touch the air nipple near the bottom of the tank found under a blue cap Fit the reserve tank shut off valve see picture below to the 1 4 water stud Hand tighten until it is snug Over tightening may cause damage See Fig 11 Insert BLACK 3 8 tubing into the tank shut off valve Push tubing all the way in then pull back gently to check fit Most push pull fittings take about a 2 of tubing inserted into them Make sure reserve tank shut off valve is in the closed position where the blue handle is perpendicular to the body gt VIDEO INSTALLATION INSTRUCTIONS AVAILABLE ONLINE lt 7 Pressurize the Tap Master RO For Tap Master UV amp ULTRA first connect power adapter to UV filter so the filter glows blue Audible alert should sound when the connection is not complete either not connected to UV filter or UV filter burnt out Make sure unit is dry Water should flow normally from your main kitchen faucet Double check to
3. Tap Master Series Reverse Osmosis System Owners Manual 10 Tips for an Easy and Successful Installation 1 Keep it simple there are 4 connections to make and the tubing is color coded VIDEO INSTRUCTIONS ARE AVAILABLE ONLINE 6 PARTS 2 Have plenty of time light space and towels before getting started If everything goes well you should be done in 45 minutes However if your feed water line is a different size or if you don t have an extra hole for the faucet it can take somewhat longer 3 NEVER use plumber s putty thread lock or anything else you wouldn t eat any part of this system You may use as much white Teflon plumber s tape as you like If you use plumber s putty on your faucet you will have disgusting and potentially toxic water for the life of the fau cet 4 Mount the faucet first and when making the final connection use the quick connect faucet adapter found in the bag of parts with the EZ adapter tank valve and drain clamp 5 If you have a 3 hole sink and want to avoid drilling 4 hole for the RO faucet then get a single handle kitchen faucet This will free up 2 holes one of which you may use for the RO fau cet the other you can use for a soap dispenser or side sprayer Tap Master 6 Mount the Tap Master vertically so that the back cap is on top There is only one black cap Tap Master Artesian Full Contact and it has one grey fitting at its top Mount the optional permeate pu
4. base cover plate with marker See Fig 2 Place towel underneath sink below drilling site to collect fillings Always wear protective eyewear and gear while drilling and while under sink 2 Using masonry bit and variable speed corded power drill slowly begin drilling through the porcelain Drill bit should be perpendicular to sink Failure to do so may cause the drill bit to slip and cause bodily injury and or property damage Rinse amp dry drill bit tip and sink area with cool water for every 20 seconds of drilling to prevent drill bit overheating and sink damage Small localized flaking or chipping may occur Use caution drill bit may be very hot DO NOT Page 4 Customer Service Hotline 1 877 693 PURE Tap Master Series Reverse Osmosis System Owners Manual No water or ice from refrigerator water center Make sure line from Tap Master RO to refrigerator has pressure Make sure refrigerator water center and or icemaker are turned ON and refrigerator is plugged in If water center works but icemaker does not then defrost the freezer as the line may have frozen Hissing or flowing sounds from Tap Master RO are normal during the water purification process Sounds should last for approximately 1 hour per gallon of water used Sounds should stop once the reserve tank is full Permeate pump equipped systems will click and whoosh Air Bubbles tiny air bubbles often accompany a new system installation and filter changes Ai
5. damaged while rolling the refrigerator Trim extra tubing Make sure the cut is straight the edge is completely smooth and the tube is rounded A scratched gouged damaged or oblong end will leak Connect the female metal fitting from the refrigerator kit to the male metal fitting on the refrigerator See Fig 14 Make sure all male metal fittings are thoroughly Teflon taped to prevent leaks Do not roll back refrigerator until the Tap Master is fully installed and operational Make sure shut off valve on the refrigerator connection kit at the Tap Master is in the OFF position where the blue handle will be perpendicular to the body 4 Mount the Tap Master Identify location for installing mounting clips for the Tap Master RO unit Location should allow room for the reserve tank for connecting and disconnecting the unit and enough room for performing general service on the unit Typical locations are on either right or left side near the back wall Use supplied mounting clips and mounting template located inside back cover Tap Master should be mounted vertically where the drain line out is on the bottom of the Tap Master See Fig 8 amp 12 Insert ORANGE 1 4 tubing into EZ adapter used in step 1 VIDEO INSTALLATION INSTRUCTIONS AVAILABLE ONLINE 5 Install water out line to RO faucet Screw quick connect faucet adapter onto the bottom of the RO faucet threaded shank until it is snug See Fig 15 Over tightening may cause damage Insert
6. enough space to mount the drain saddle clamp See Fig 8 amp Fig 10 Drainpipe material can be either metal or plastic Locate drain hole template supplied with drain saddle clamp and peel off its backing Place the template on the previously identified location of drainpipe for the drain saddle clamp Place 1 4 drill bit inside template hole and drill a hole into the drainpipe Drill through one side only DO NOT drill a hole clean through both sides of the drainpipe This will result in a leak and require replacement of that piece of drainpipe Mount the drain saddle clamp on top of the template with the holes aligned You may use a screwdriver to align the holes Fit drain saddle clamp back plate and screws Alternate tightening screws on each side of the drain saddle clamp to ensure an even snug fit See Fig 10 Locate RED 1 4 drain tubing and push on black plastic nut found in drain saddle bag Hand tighten black plastic nut Page 5 Customer Service Hotline 1 877 693 PURE Tap Master Series Reverse Osmosis System Owners Manual onto the drain saddle male fitting until it is snug Wrap excess tubing around the drainpipe 2a Mounting Permeate Pump optional Mount permeate pump side by side with the tap master using supplied mounting clip and screws IMPORTANT permeate pump must be mounted with indicator arrow pointing up Indicator arrow is the large center arrow See page 10 for mounting orientation diagram 3 Install re
7. er 50 60Hz 110 240v featuring audible alert Flow restriction architecture integrated flow restrictor and water check valve central auto shut off valve Drain saddle all fittings and connecting hardware Reserve tank 3 2 gallon or 9 gal upgrade stand quick connect ball valve Chrome long reach sink faucet or custom faucet quick connect fitting and hardware EZ adapter feed water adapter 3 8 mc x 3 8 fc x 1 4 tube Maintenance Schedule Sediment filter annual replacement Carbon filter s annual replacement IRON carbon filtert 6 month replacement UV filter annual replacement Membrane 50 gpd TFM 4 5 year replacement Artesian filter annual replacement General System Specifications Feed water PSI 40 100 PSI Feed water Temperature 40 100 F Max Total Dissolved Solids TDS 2000 ppm Max Hardness 10 gpg DH limits 4 10 1 Included with Tap Master IRON and ULTRA only 4 Included with Tap Master Artesian only 2 Included with Tap Master standard and UV only 3 Included with Tap Master UV and ULTRA only Page 3 Customer Service Hotline 1 877 693 PURE Tap Master Series Reverse Osmosis System Owners Manual System Location The Tap Master may be installed under a sink or in a basement within 20 feet of the RO sink faucet as long as the Tap Master is not subjected to freezing temperatures The Tap Master Should be mounted vertically where the drain line out is at the bottom Mount the res
8. er Service Hotline 1 877 693 PURE Customer Service Hotline 1 877 693 PURE Tap Master Series Reverse Osmosis System Owners Manual ALLOW CLEARANCE FROM TOP _ Mounted RO sink spigot 0 2 02 42 amsav Page 2 ALLOW CLEARANCE FROM BOTTOM Page 11 Customer Service Hotline 1 877 693 PURE Customer 5 Tap Master Series Reverse Osmosis System Owners Manual 2 If the flow to the membrane housing is strong then check the water flow exiting the white fitting at the bottom of the membrane housing The water flow from the tube Should be a thin but steady trickle If not then the membrane is plugged and should be replaced Please note that the minimum water pressure for the system to operate is 40psi 3 If the flow to the membrane housing is weak then start working your way backward and check each connection point until you find the blockage point At each point turn off the water at the EZ adapter and tank and briefly turn on the RO faucet at the sink to relieve any system pressure Disconnect the tube from the fitting Point the tube you have just disconnected into a pitcher and turn on the EZ adapter valve Discoloration of water The first batch of water produced from your purification system may be discolored due to the presence of carbon from the carbon filters and a small amount of preservative This is normal DO NOT drink the first 6 5 gallons of water Drinking from un flu
9. erve tank on a sturdy shelf because it will weigh over thirty pounds when full Tools Required Safety glasses Towels Phillips screwdriver Scissors Medium Crescent wrench Medium pliers Felt tip pen or marker Variable speed corded power drill 3 8 for the sink hole 14 for the remainder 14 metal drill bit w cobalt tip 1 metal drill bit w cobalt tip not required if sink has a pre drilled hole 1 masonry drill bit not required if sink has pre drilled hole or if sink is not porcelain VIDEO INSTALLATION INSTRUCTIONS AVAILABLE ONLINE www theperfectwater com Installation Instructions html TUBING COLOR CODING ORANGE LINE IN BLACK TO STORAGE TANK RED TO DRAIN BLUE TO RO FAUCET Drilling hole for RO faucet porcelain sinks steps 1 5 stainless sinks steps 3 5 WARNING Serious cracking and damage may occur to your sink even if instructions are followed exactly due to age and the imperfections inherent in natural materials Instructions may not apply exactly to your sink Use caution sink may be slippery 1 Remove base cover plate from RO faucet packaging Line up base cover plate with other sink faucets See Fig 1 Check underside of sink for spacing from trim curvatures and other obstacles See Fig 15 Don t place spigot too close to obstacles leave yourself enough room under the sink to use hand tools Either right or left side of the sink is OK provided previous conditions are met Mark center of
10. frigerator kit optional Installation may vary according to make model and age of your refrigerator Make sure refrigerator icemaker and water center are turned OFF Clean area below and around refrigerator thoroughly Use care when rolling out refrigerator Flooring may become scratched gouged or damaged from moving refrigerator Consult your local licensed contractor or plumber for trimmed in refrigerators or refrigerators without rollers Roll out refrigerator Unplug refrigerator electric plug Locate water line in for refrigerator Yours may already be connected to a water line from wall If so use local angle stop to shut off water Disconnect female fitting See Fig 13 Plan the route for the water line from the Tap Master Drill 14 holes through the lower cabinetry high along the back wall just below the drawers See Fig 9 Make sure cabinet contents are removed prior to drilling and 1 4 tubing does not come into contact with drawers doors or sharp objects Smooth the holes free from splinters and sharp edges Alternate route for refrigerator line run refrigerator tubing along the baseboard and enter the kitchen sink cabinet by drilling a opening in the bottom board of your kitchen sink cabinet towards the front baseboard Push tubing through the cabinetry holes from the Tap Master RO to refrigerator Allow 2 4 of extra tubing at the refrigerator and position it so that it cannot be crushed or otherwise
11. ing Push tubing all the way in then pull back gently to check fit Most push pull fittings take about a 1 3 of tubing inserted into them Page 8 Customer Service Hotline 1 877 693 PURE Tap Master Series Reverse Osmosis System Owners Manual touch drill bit Electrical hazard DO NOT allow power drill electrical components to come into contact with water Use caution sink may be slippery 3 When metal is struck switch to 4 metal bit with cobalt tip Drill bit should be perpendicular to sink Failure to do so may cause the drill bit to slip and cause bodily injury and or property damage Begin drilling to drill a hole all the way through the sink Rinse amp dry drill bit tip and sink area with cool water for every 20 seconds of drilling to prevent drill bit overheating and sink damage Small localized flaking or chipping may occur 4 When 1 4 hole is completely drilled through switch to 2 metal drill bit w cobalt tip Drill bit should be perpendicular to sink Failure to do so may cause the drill bit to slip and cause bodily injury and or property damage Begin drilling to enlarge the 1 4 hole to all the way through the sink Use caution when hole is near completion to avoid damaging sink surface Rinse amp dry drill bit tip and sink area with cool water for every 20 seconds of drilling to prevent drill bit overheating and sink damage Small localized flaking or chipping may occur 5 When gt hole
12. is drilled through completely install RO faucet with provided mounting hardware For more details see mounting instructions enclosed with hardware See Fig 3 Connect Tap Master to RO faucet using Quick connect faucet adapter as outlined later Installing The Tap Master Reverse Osmosis System A RO Faucet Mount faucet according to the installation instructions enclosed with faucet packaging 1 Install EZ adapter on cold water line Always wear protective eyewear while under sink Locate the cold angle stop the main water lines under the sink one hot water one cold water and turn clock wise to shut off the water See Fig 4 Locate 3 8 fitting typically found on the line out of the angle stop see Fig 7 or where the existing line connects to the kitchen faucet See fig 6 Disconnect the 3 8 fitting on either the angle stop or the kitchen faucet Use Teflon tape on the EZ adapter and the angle stop male threads and make sure o rings are properly seated Fit the EZ adapter and tighten Check for water pressure amp leaks on ball valve Turn ON water by rotating angle stop counter clockwise Close ball valve by turning the handle perpendicular to the ball valve body Valve is closed in Fig 7 Have a bowl cup nearby to catch water Dry all parts check for leaks and snugness VIDEO INSTALLATION INSTRUCTIONS AVAILABLE ONLINE 2 Install drain saddle clamp and drain line Identify a vertical section of drainpipe with
13. make sure all valves are in the closed position except for the main angle stop valve which should be open SLOWLY open the EZ adapter ball valve You should hear water rushing through the system Open the RO faucet to by flipping the lever up where it should stay open A trickle of water should be present after 2 20 minutes Some blackening of the water may present due to loose carbon being flushed out Close the lever on the RO faucet after the trickle runs clear and allow the system to pressurize When the system has pressurized and Shut off check for leaks Then open the reserve tank valve slowly Allow reserve tank to fill for 2 5 hours and then drain completely You will drain the tank by opening the RO faucet Let run until trickle present again Close Ro faucet Let refill and repeat System must be flushed at least twice prior to use OPTIONAL Plug in refrigerator electric plug open refrigerator line ball valve so that the blue handle is parallel with the white body Make sure refrigerator icemaker and water center are turned ON Check for leaks Check for pressure at the refrigerator s water center Dispose of the first two batches of ice after installing the Tap Master RO Use caution when rolling refrigerator back into place DO NOT crimp or crush water line as a leak will likely develop IMPORTANT After reserve tank has filled 2 5 hours Drain entire reserve tank completely until the flow from the RO faucet falls to a thin steady
14. mp correctly nothing will work There is a big arrow on the permeate pump make sure it points up Tap Master IRON 7 Mount the drain saddle on a vertical section of drain pipe IF you have to mount the drain Tap Master UV saddle on a horizontal section then drill the hole on the top side of the pipe or at least at an an T Mast ULTRA gle where the drain water from the Tap Master drops down into the drain pipe Think of a man Master hole passage into the sewer When making the connection from the system to the drain saddle wrap the tubing around the drain pipe a few times so that some loops of tubing are higher than the fitting 8 DO NOT touch the air nipple on the side of the reserve tank You may be tempted to check the pressure or pump it up don t It already has plenty of air Adding more will not boost flow it will only decrease tank capacity Read the instructions thoroughly before beginning There is allot of information there some of which you may not need for your application If you have questions call or email Email will usually be answered within hours even at night 10 Have patience Your new Tap Master may take some time to break in and start flowing Make sure you fill and drain the reserve tank at least twice TUBING COLOR CODING ORANGE LINE IN BLACK TO STORAGE TANK RED TO DRAIN BLUE TO RO FAUCET Perfect Water Technologies Inc Copyright 2010 PERFECT WATER Page 12 Custom
15. ny time and for any reason first close all under sink water valves except for the RO faucet which you Should open to relieve system pressure and drain away excess water from the lines Push pull and quick connect fittings are nearly impossible to remove when under pressure Leaks from metal fittings Unscrew fittings and re tape male fitting Tape should be wound 5 7 times around male thread Tape should not cover opening Use only Teflon tape Re tighten fitting securely Over tightening can crush the tubing insert and cause a water blockage Leaks from plastic fittings Plastic fittings should be firmly finger tightened Under tightening can result in leaks over tightening can crush the tubing and result in a water blockage For plastic fittings only make sure the plastic tubing has an insert in the tube end anda feral o ring which compresses the tubing around the insert in the plastic female fitting Drain tubing does not need an insert Leaks from push pull or quick connect fittings Disconnect fitting by depressing the collet ring on the fitting with one hand and pulling out the tubing with the other hand while the collet ring is still depressed Tubing cannot be pulled out without depressing the collet ring and relieving system pressure Make sure the tubing is cut is straight the edge is completely smooth and the tube is rounded Scratched gouged damaged or oblong tubing end will leak Re insert the tubing into the push pull fitt
16. r becomes trapped inside the tiny carbon pores and is released over time not gallons After pouring a glass of water allow a few seconds for the water to clear Enjoy Weak pressure at RO sink faucet amp Reserve tank filling slowly NOTE Seasonal changes in temperature can cause pressure imbalances within the system resulting in slow water production Oftentimes the imbalance will correct itself on its own within a few days You may also restore the internal system pressure balance by draining the tank unplugging the tubing from the tank then allow the system to stand open overnight Turn it back on and allow the tank to refill Weak pressure is either a storage problem or a production problem To determine which close the tank valve and open the RO faucet You should see a constant trickle of water If this is what you see then it s a storage tank problem If you see zero water dribbles out or a few drops only then it s a production problem Storage tank problems 1 Make sure storage tank is full and has been flushed at least twice 6 5 gallons 2 Make sure the angle stop is wide open 3 Check all tubing for kinks or sharp bends this can impede the flow of water 4 Check reserve tank air pressure with tank empty system off and faucet open Air valve is located on the side of the tank under a cap Use a bicycle tire pressure gauge Tank should have 7 5 psi If the pressure is less then add air using a bicycle pump Do not
17. shed system may cause gastrointestinal discomfort colic and or diarrhea Consult a physician if discomfort persists Running out the first two tanks will effectively flush out the system and make it ready for use The tank is full when the hissing or clicking stops Permeate pump should be mounted with inlet and outlet ports to the sides and the center indicating arrow pointing up MOUNTING ORIENTATION CORRECT INCORRECT Page 10 Customer Service Hotline 1 877 693 PURE Tap Master Series Reverse Osmosis System Owners Manual Tap Master Contents Instruction book detailed descriptions photos and troubleshooting guide 10 Sediment pre filter 5 micron bonded spun poly with high holding depth 1 year service life 10 IRON Carbon pre filter 5 micron granular activated carbon coconut shell carbon with IRON filtration 6 month or 1500 gallon service life 10 Carbon pre filter 5 micron granular activated carbon coconut shell carbon 1 year or 3900 gallon service life 10 Carbon post filter 5 micron granular activated carbon coconut shell carbon 1 year or 3900 gallon service life 10 Artesian post filter 5 micron granular activated carbon coconut shell carbon with advanced remineralization media 1 year or 2500 gallon service life Thin Film Composite membrane 0 001 micron ultra fine pore 50 gallon per day 4 5 year service life UV filter 1 year service life with universal electronic transform
18. trickle Repeat Reserve tank is full when the hissing or clicking noise stops Discoloration of water may be present System must be flushed twice prior to use Allow another 3 hours for the reserve tank to refill Faucet Adapter EZ Adapter Tank Shut off Valve Page 7 Customer Service Hotline 1 877 693 PURE

Download Pdf Manuals

image

Related Search

Related Contents

Computer Gear 26-0100MM  Q24 User Manual - Galileo Equipments  Sky02 3D Goggles User Manual Here  Simulateur de logidules    Película de Protecção ScotchcalTM 3647  Commands - Flint Machine Tools, Inc.  MANUAL DE INSTALACIÓN PISO WPC  Smeg-PLA6045X - Instructions Manuals  Equip 24-Port Keystone Cat.6A Unshielded Patch Panel  

Copyright © All rights reserved.
Failed to retrieve file