Home
        Guardian
         Contents
1.    If the Safety Burst Disc requires service start by contacting Air America   for a proper replacement disc  Using  another disc assembly could result in harm to the Guardian    and  or individuals  Begin by removing the safety  jam nut with a 3 16 inch Allen key  exposing the orifice washer and ruptured disc assembly  Turn the tester over  to allow the disc and washer to fall out  If they do not come out easily take a pick and CAREFULLY pry them  out  CAUTION  DO NOT DAMAGE OR SCORE THE BOTTOM OF THE SAFETY POCKET  Damage to the  bottom of the safety pocket will result in an improper seal and premature failure of the new safety burst disc     Prior to installing your new safety burst disc  orifice washer and jam nut  it is best to clean the tester body  Take  a cotton swab and dip the end into some alcohol  now wipe the inside of the tester body and thread area   Repeat this process until the cotton swab comes out clean  this may take several applications  Caution  Be  sure not leave any cotton residue in the tester  Install the burst disc covered by the orifice washer  The  orifice washer should be placed rounded side up for best results  IMPORTANT NOTE  Do not replace the  orifice washer with ANYTHING other than an Air America   orifice washer  The dimensions have been  specifically calculated  After the bust disc and washer are in place install the hex head jam nut and torque to  15 20 ft lbs  to complete the procedure     Page 3 of 4    Guardian        Trouble Shooting 
2.  times by rotating the rotary bleed valve  counterclockwise  it is NOT necessary to rotate the valve more than a quarter turn  purging any trapped air in  the regulator passages and allowing the system pressure to stabilize  You can also utilize this procedure to  simulate firing the marker  thereby judging the response time of your air system  After cycling the Guardian     several times take note of the gauge reading  if you feel that adjustments are needed to the output pressure of  the primary regulator  do so and cycle the system again to stabilize the pressure  Repeat this procedure until  you reach the desired output pressure of the primary regulator being tested  CAUTION  BEFORE  DISCONNECTING AND REMOVING THE GUARDIAN    BE SURE THAT THE SYSTEM HAS BEEN  TURNED OFF AND THE ROTARY BLEED VALVE IS OPEN  This shut down procedure will allow any trapped  pressure in the system to escape and enable a safe removal of the primary regulator     Testing secondary regulators  The Air America   Guardian    is designed to allow easy adjustment of secondary regulators  Most secondary    regulators are equipped with a standard ASA male fitting on one end  Testing a regulator with this type of fitting  requires you to simply screw the regulator into the female ASA port on the Guardian     If your secondary    Page 2 of 4    regulator requires a different configuration  use the Air America   ASA adapter and fittings supplied with your  Guardian    to attach the output port of the regu
3. 2240 Elmhurst Road Elk Grove Village  IL 60007 USA 847 545 9999 Fax  847 545 0275  www airamerica com    Guardian    Universal Regulator Tester   Service Manual    Congratulations on your purchase of the Air America   Guardian    Universal Regulator Tester  Precision  machined and anodized  from certified quality aerospace aluminum alloy  your Guardian    Universal Regulator  Tester is an indispensable field or bench tool specifically designed to provide a fast fail safe accurate way to  tune your Air Nitrogen delivery and regulation systems     tm    Introduction  The Air America   Limited Lifetime Warranty guarantees a lifetime of trouble free service and accuracy while  providing the highest safety and equipment standards in the sport of Paintball     Guardian    Standard features include    Low pressure safety to prevent over pressurization of the system  Rotational bleed valve that will allow you to cycle your system   Marker discharge simulation    180 degree sweep gauge for accurate pressure readings  Exterior knurling to allow one had operation   Skirted knob to direct air flow during the bleed phase  Internationally famous Air America   Limited Lifetime Warranty    SAFETY ALERT      ALWAYS DE GAS YOUR SYSTEM  BEFORE YOU ATTEMPT ANY SERVICE OR REPAIR     NOTE  To achieve maximum benefit from your factory replacement parts  have them  installed by an authorized AIR AMERICA   technician  Additional technical assistance  is available through the internet at www airameric
4. Guide  Note  The following chart is for reference purposes only  Air America   recommends that all safety precautions  as  outlined in the Service Manual  are strictly adhered to before any repairs or testing procedures are attempted  In the  event  repairs are required certified Air America   technicians using factory replacement parts should be relied upon to  achieve maximum performance from your system  Additional technical assistance is available at www airamerica com              Bleed Valve Position Gauge Action Possible Cause Probable System Repair  Closed Steady No Leaks   Normal Normal  Cycled 1 16 To 1 4 Drops Slightly  amp  Normal Normal    Turn    Rapidly  Returns          To Preset  Pressure  amp  Holds  Steady  Closed Reads Zero System Obstruction Remove Obstruction  amp  Clean Regulator  Regulator Adjustment Nut Out   Turn On System  Of Adjustment  Improperly Set   Adjust Regulator Output Pressure   Closed Slowly Rises Faulty Pin Seat Replace With Factory Replacement Parts     Creeps  Past Set  Pressure     Dirt Debris In Regulator    Clean Regulator       Cycled 1 16 To 1 4  Turn    Pressure Drops  Then Slowly   Climbs Back To  Preset Pressure    Non Air America   Regulator  Seat  amp  Pin    Wrong Piston O  Ring  Wrong Spring Pack  Improper Piston Spring Pack  Lubricant    Defective Spring Pack  Dirt Debris In Regulator    Replace With Air America   Seat  amp  Pin  Replace With Air America   O ring   Replace With Air America   Spring Pack  Clean Assemblies  
5. a com     Page   of 4    Terminology    Take the time and use the following exploded view of the Air America   Guardian    Universal Regulator tester to  familiarize yourself with the names and locations of the parts you will be working with  Doing so will make the  instructions for use clearer and enable you to be more proficient in your testing procedures       Safety Orifice Washer    Seat  lt  Safety Burst Disk    ASA O  Ring Orifice Washer   Safety Burst Disk    Regulator Valve Pin                      i                            Male Q Disconnect          i       Jam Hex Nut Main Body       ASA Adapter    Using the Air America   Guardian        To test primary regulators   Install the Air America   ASA Adapter supplied with your Guardian    tester into the female port located on the  bottom of the Guardian     Using a combination of hose and fittings to match your current air delivery system   connect the output side of your air system to the ASA Adapter on the Guardian     NOTE  to prevent  premature bleed off of the systems tank pressure the Rotary Bleed Valve on the Guardian    must be in a  HAND TIGHT fully closed  clockwise  position  Once the primary regulator is connected to the Guardian      you may then pressurize the system  The gauge on the Guardian    will read output system pressure  pressure  going into the marker or secondary regulator   NOTE  Before you make any adjustments to the output pressure  of your primary regulator  cycle the Guardian    several
6. amp  Relubicate With Proper  Lubricant   Replace Spring Pack   Clean Regulator                Closed Steady Beyond Bad Seat  amp  Pin Replace Seat  amp  Pin  Preset Pressure   Wrong Piston O  Ring Replace With Air America   O ring  System Leaks Piston Binding In Housing Free Bind  amp  Clean Assembly  Replace O  Ring  amp   Out Of Regulator   Dirt In Regulator Lubricate   Nut Until Tank Regulator Set To High Clean Regulator  Reaches Reset Output Pressure To Lower Pressure   Approximately  1200 PSI  Safety  Functioning  Properly Ignore  Leak   Closed Steady System Defective O Ring Replace With Air America   O ring  Leaks Out Piston Safety Failure Replace Piston Assembly  Regulator Nit  Cycled 1 16 To 1 4 Drops  amp  Stays Internal Obstruction To Remove Obstruction  amp  Clean Regulator  Turn Low Regulator Replace With Air America   Seat  amp  Pin          Non Air America   Regulator  Seat  amp  Pin  Dirt Debris In Regulator       Clean Regulator           ALL RIGHTS RESERVED  AIR AMERICA  INC   20    Page 4 of 4       
7. de faces up  insert the 1 4 inch Allen key in the jam nut  Remove the jam nut  followed by the Stainless Steel Orifice Washer  Once these parts are removed the Regulator Seat should fall  out  if not  gently press it out from the Bleed Valve side with the 3 16 inch Allen key     Prior to installing your new Regulator Seat and Valve Pin  it is best to clean the housing  Take a cotton swab  and dip the end into some alcohol  now wipe the inside of the Tester body and Bleed Valve  Repeat this  process until the cotton swab comes out clean  this may take several applications  Caution  Be sure not leave  any cotton residue in the tester  To install the new Regulator Seat and Valve Pin start by inserting the  Regulator Seat narrow side first  then install the Stainless Steel Orifice Washer smooth side facing the seat   Use the 1 4 inch Allen key to install and sufficiently tighten the jam nut to prevent a Regulator Seat leak  NOTE   Regulator Seats have a taper to them with one side being wider than the other     Rotate the Main Body till the ASA adapter portion is facing down  Now insert the Valve Pin  long narrow end  first  into the bore for the Rotary Bleed Valve  BEFORE installing the Bleed Valve use a cotton swab to put a  small amount of Anti seize lubricant onto the valves thread area and onto the pin bore located at the bottom of  the Bleed Valve  Now install the Rotary Bleed Valve by screwing it in  clockwise   do not worry about the pin  assembly  it   s self centering  
8. lator to the inlet side of your Guardian     Once the proper ASA  connections are made and your secondary regulator is connected to the Guardian    you may then pressurize  the system  follow the same procedures as outlined for the testing of the primary regulator  NOTE  to prevent  premature bleed off of the systems tank pressure the Rotary Bleed Valve on the Guardian    must be in a  HAND TIGHT fully closed  clockwise  position     Servicing the Air America   Guardian       The Air America   Guardian    has been engineered for a lifetime reliable service  If service is ever required Air  America   will service your tester upon request  If you choose to do the repairs yourself the following  procedures and safeguards should be utilized  The Guardian    has been designed to use many of the standard  Air America   replacement parts currently available in the Air America   parts kits  The standard Air America    Regulator Seat and Valve Pin Assembly are located in the main body of the tester  These are the only service  replacement parts you will need to bring your Guardian    back to    like new    condition     The Guardian    can be completely disassembled with the following tools  3 16 inch Allen key and a 1 4 inch  Allen key  Start the disassembly by removing the Rotary Bleed Valve from the tester entirely  Turning the tester  over will allow the Valve Pin assembly to fall out of the tester body  Once Valve Pin assembly has been remove  rotate the tester so that the ASA si
    
Download Pdf Manuals
 
 
    
Related Search
 Guardian  guardian  guardian dental  guardian anytime  guardians of the galaxy  guardian uk  guardian news  guardian life  guardian insurance  guardian browser  guardian ad litem  guardian bikes  guardians vs rangers  guardian dental provider portal  guardians of the galaxy 3  guardian vision  guardian dental provider login  guardian life insurance  guardians score  guardians schedule  guardian browser download  guardian dental insurance  guardian newspaper uk  guardian tales  guardian credit union  guardian druid 
    
Related Contents
取扱説明書  istruzioni multilingua  巳64-467 XZ-6534LSG セツメイショ ] 〇壁スイ ッチのみで使用される  Usermanual UK-DE-FR-IT-SP-CZ PRIMA II-MG01-01  Drum Sound Module TD-30  Jolt control for drive system  SELFTENE - Index S.p.A.  RCF 4  3Dクラシックス ゼビウス  MANUAL DE INSTRUÇÕES - Besøg masterpiece.dk    Copyright © All rights reserved. 