1. SPECIFICATION OF Plastic Bins Yellow Big Appendix S 4 NS 13 MATERIAL Plastic HDPE LLDPE bins made from virgin polymer material thickness of Bins bin shall be minimum 2 5 mm 0 2 mm with foot operated lid and handles for lifting also refer IS 3730 1988 for details Lid mechanism shall be of SS material only CLASS amp SIZES BIG 25 Lt 150 DIMENSIONS HDPE bucket of Circular Top of about 340mm 10mm without collar amp circular Bottom of about 280mm 10mm Height 360mm 10mm with suitably designed foot operated lid and proper handles for lifting the bin SS pipe wire rod used for cage handle and for operation of lid shall not be less than 4mm dia SS rod SS Square hollow pipe 2 Nos of 20x20 mm shall be provided at the bottom for steady placement of the bin SS pipe wire rod shall be not less than 4 mm dia WORKMANSHIP amp FINISH As per IS 3730 1988 for HDPE LLDPE bin SS parts shall be smooth finished and powder coated proper rubber studs shall be provided on the paddle and both ends of 20mm SS square hollow pipe REQUIREMENTS Lid of the Bin shall be foot operated and SS bottom rod of foot operated mechanism shall be minimum 8 mm It shall close to secure infected contents immediately upon releasing pressure Other requirements as per IS 3730 1988 Bin shall be pre
2. 5 Environmental factors Technical Bidders Specs Deviation quoted by if any bidder 5 1 The unit shall be capable of operating continuously in ambient temperature of 10 40deg C and relative humidity of 15 90 5 2 The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C and relative humidity of 15 90 5 3 Shall meet IEC 60601 1 2 2001 Or Equivalent BIS General Requirements of Safety for Electromagnetic Compatibility or should comply with 89 366 EEC EMC directive 5 4 The supplier shall provide environment friendly furnitures and wall fittings for the entire system Cabling has to be provided by the supplier 6 Power Supply SI Name Technical Bidders Specs Deviation quoted by if any bidder 6 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 6 2 Internal Battery back up for 1 hour or suitable UPS 29 7 Standards Safety and Training Technical Bidders Specs Deviation quoted by if any bidder 7 1 Should be FDA CE UL approved product 7 2 Shall meet the safety requirements as per IEC 60601 2 27 1994 Medical electrical equipment Part 2 Particular requirements for the safety of electrocardiographic monitoring equipment 7 3 Manufacturer Supplier should have ISO certification for quality standards 7 4 Should have local service facility The service provider should have the necessary equipments recommended by the manufacturer to carry out p
3. 7 Standards Safety and Training Technical Bidders Specs Deviation if 104 quoted by bidder Tel Jaz 7 3 7 4 Should be FDA CE UL BIS approved product Manufacturer should have ISO certification for quality standards Comprehensive training for lab staff and support services till familiarity with the system Comprehensive warranty for 3 years 8 Documentation 8 1 8 2 8 3 8 4 8 5 8 6 Technical Specs quoted by bidder User Technical Maintenance manuals to be supplied in English List of important spare parts and accessories with their part number and costing Certificate of calibration and inspection Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job descriptin of the hospital technician and company service engineer should be clearly spelt out Compliance Report to be submitted in a tabulated and point wise manner clearly mentioning the page para number of original catalogue data sheet Any point if not substantiated with authenticated catalogue manual will not be considered List of Equipments available for providing calibration and routine Preventive Maintenance Support as per manufacturer documentation in service technical manual 105 Bidders Deviation if any 48 Public Address System TECHNICAL SPECIFICATIONS PUBLIC ADDRESS SYSTEM The voice alarm system shall be the integrated solution for BGM Back ground Music
4. 14 Auto On Auto Off Technology should be available 15 Warranty Minimum of 3 years onsite comprehensive warranty and 3 years CMC SDSL Symmetric Digital Subscriber Line Modem SDSL modems works on SDSL lines that provide equal bandwidth in both directions Such types of modems are useful for those businesses which need to upload as well as download large files or programs to or from the Internet These modems use voice traffic lanes to expand bandwidth and therefore aborting the possibility of a conversation when the SDSL modem is connected For this purpose a dedicated phone line is required Warranty Minimum of 3 years onsite comprehensive warranty Warranty Minimum of 3 years onsite comprehensive warranty and 3 years CMC 3 1 Mbps EVDO High Speed Data Wireless phone that connects up to 8 Wi Fi devices 35 High Quality CDMA voice data and SMS services Warranty Minimum of 3 years onsite comprehensive warranty and 3 years CMC 36 Diet Trolley that is suitable to provide various food items without intermixing it Trolley to be used for serving food hot and make them free from contaminates Material and finish of trolley to be of good quality raw material with flawless manufacturing The Standard of this trolley should be in conformity with prevalent market standards Warranty Standard Warranty terms 37 13 Doctor s Table The size of the doctors table should be 1370mmWi
5. Shortest fuel pipe routing with minimum number of bends Gravity feed of minimum 300 mm above fuel pump inlet line for critical start AMF sets Gas Genset Gas pipe line size is as per recommendations Gas pressure available at Genset room is within limit Manual shut off valve outside the genset room Incase of multiple sets suitable expansion reserve tank is provided Primary gas filter to ensure clean amp dry gas Provision of Pressure gauges at recommended locations 57 Flexible pipe between gas train and engine Earthing across flanges and flexible pipe Location should not obstruct flow of fresh air Should not obstruct movement Proper visibility Cabling as per recommendation Ill Obtain from the competent authorities for grant of permission for installation of Generating Set s List of Approved Makes Sr no Equipment Make Make Offered 01 Engine Engine Cummins Greaves Leyland Kirloskar Oil Engines 58 02 Alternator Alternator Kirloskar Electric Crompton Greaves Stamford NGEF 03 Cable CCI Polycab NICCO Asian Gloster Finolex 04 Cable Gland Comet Braco Dowell 05 Cable Lugs Siemens Dowell 06 TPN SFU L amp T Siemens Alstom Contactors and ABB Relays 07 Energy Meter Alstom Havels 08 Voltmeter Ammeter Meco AE 09 Cable Tray s Kappa Pragathi ECS AE 10 Battery Exide Standard Furukhawa OKAYA IV Warranty 3 years warrantee amp CMC contract form with charges
6. 11 0 11 6 of compressor at rates voltage at IS rated test condition 4 System Configuration Accessories spares and consumables Technical Bidders Specs Deviation if quoted by any bidder 4 1 System as specified 5 Environmental factors Sl Name Technical Bidders Specs Deviation if quoted by any bidder 5 1 The unit shall be capable of being stored continuously in ambient temperature of 0 50 deg C and relative humidity of 15 90 5 2 The unit shall be capable of operating continuously in ambient temperature of 5 to 45 deg C and relative humidity of 15 90 6 Power Supply 126 Technical Bidders Specs Deviation if quoted by any bidder 6 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 6 2 Suitable Automatic Voltage regulator stabilizer meeting ISI specifications should be supplied Broad specifications are Automatic Type Input 150 280V Output 220 V 7 50 Hz Single phase AC with automatic 2 4 sec Cut Off and 6 9 minutes restart delay Quick start arrangements for bypassing the start delay Suitable MCB on input voltmeter and indicators on Front Panel Input Poer Cable with 15 A Plug and six way output terminal strip for two outlets 7 Standards Safety and Training Technical Bidders Specs Deviation if quoted by any bidder Pel Should be conforming to IS 1391 Part I 92 for room airconditioning Juz Manufacturer should be ISO certfied for quality standards 7 3 Com
7. amp PACKAGING Each Bin shall be packed in poly film bag to reach destination securely Also refer IS 3730 1988 SPECIFICATION OF Plastic Bins Blue Small Appendix S 4 NS 14 MATERIAL Plastic HDPE LLDPE bins made from virgin polymer material thickness of Bins bin shall be minimum 2 5 mm 0 2 mm with foot operated lid and handles for lifting also refer IS 3730 1988 for details Lid mechanism shall be of SS material only CLASS amp SIZES SMALL 15 Lt HDPE bucket of Circular Top of about 285mm 10mm without collar amp circular Bottom of about 230mm 10mm Height 290mm 10mm with suitably designed foot operated lid and proper handles for lifting the bin SS pipe wire rod used for cage handle and for operation of lid shall not be less than 4mm dia SS rod SS Square hollow pipe 2 Nos of 20x20 mm shall be provided at the bottom for steady placement of the bin DIMENSIONS SS pipe wire rod shall be not less than 4 mm dia WORKMANSHIP amp FINISH As per IS 3730 1988 for HDPE LLDPE bin 158 SS parts shall be smooth finished proper rubber studs shall be provided on the paddle and both ends of 20mm SS square hollow pipe REQUIREMENTS Lid of the Bin shall be foot operated and SS bottom rod of foot operated mechanism shall be minimum 8 mm It shall close to secure infected contents immediately upon re
8. and EVAC Emergency Voice Alarm The voice alarm system shall be designed for public address andemergency evacuation All the essential EVAC functionality such as system supervision spare amplifier switching loudspeaker line surveillance digital message management and a fireman s panel interface shall be combined A 24Vdc output shall be available to supply power to external relays so no external power supply shall be required for that purpose A LED VU meter shall allow for monitoring of the master output The maximum rated output power of the internal booster shall be 150 W 300 W max mains inrush current shall be 8A 230 VAC 16A 115 VAC The frequency response shall be 60 Hz 18 kHz 1 3 dB 10 dB ref rated output The distortion shall not exceed 1 at the rated output 1 kHz The controller shall have tone controls to allow for adjustment of the BGM sound It shall have separate bass and treble controls The controller shall have two BGM source inputs and a mic line input with configurable priority speech filter phantom power and selectable VOX activation The operating temperature range shall be 10 to 55 The storage temperature range shall be 40 to 70 The system shall comply to the following standards 1 EVAC compliance acc to IEC 60849 O EMC emission acc to EN 55103 1 0 EMC immunity acc to EN 55103 2 O Safety acc to EN 60065 The system shall be the Bosch Plena Voice Alarm System The control
9. minimum 5 AV inputs output 12 Warranty 3 years and CMC thereafter of 3 years MBasin Stand Assorted SS A High quality 304 stainless steel basin on portable Stand with castor wheels and a aquare base Wash Hand Basins The wash hand basins shall conform with the requirements specified for 350 mm diameter wash bowl in IS 3994 1967 The workmanship and finish shall be in accordance with IS 4033 Single Wash Basin Stand as per IS norms To follow 1S 4267 1967standards SHAPES AND DIMENSIONS The thickness of tubes used and corresponding outside diameters for different parts of the wash hand basin stands Shall be as given below Part Thickness of Tube Outside Dia of Tube Upright supports 1 2 mm 25 40mm Rings Basin Support 7 tie bars 1 02 mm 12 70mm 13 5 B P Apparatus Technical Specification 1 Measurement method Electronic 2 Measurement range a Numerical display Pressure 0 300 mmHg b Pulse 30 200 beats minute c Pressure bar display Pressure 20 280 mmHg 3 Measurement accuracy a Numerical display Pressure 3 mmHg 14 b Pulse 5 c Pressure bar display Pressure 4 mmHg 4 Power supply 2 x 1 5 V alkaline batteries LR6 or AA 5 Upper arm circumference 23 33 cm using the medium cuff 6 Number of measurements Approx 2000 measurements 7 when AA alkaline batteries are used with pressure value of 180 mmHg at room temperature of 23 C 8 Classification Internally powered ME equipment 9 Con
10. prongs Nasal tubings Silicon 70mm at least 20 with each machine Nasal prongs with each machine 1 Size 3 0mm 2 0mm x 20 2 3 5mm 2 0mm x 20 3 4 0mm 3 0mm x 20 Infant Head bonnet with each machine1 Size 22cm 25 cm x 20 2 25cm 29cm x 20 3 29cm 36cm x 20 Head gear 29 36cm x 20 16 10 11 12 13 14 15 16 17 Chin strap 26 32cm x 5 20 32 38cm x 5 20 Provision to deliver gas with selectable FiO2 21 100 Unit should be supplied with Mobile stand with castor mounting brackets C clamp amp IV hook Unit should be supplied with proper demonstration user manual setup guides amp proper service back up Unit should be supplied with International FDAor CE European Conformity safety regulations amp certifications Documentation User Manual in English Service manual in English List of important spare parts and accessories with their part number and costing Certificate of calibration and inspection from factory Log book with instruction for daily weekly monthly and quarterly maintenance checklist with visits by company service engineer in log book The job description of the hospital technician and company service engineer should be clearly spelt out List of Equipments available for providing calibration and routine maintenance support as per manufacturer documentation in service technical manual Function Complete solution to all difficulties faced in Bag n
11. should be able to run uninterruptedly for one hour Max Press 2 0 2 5 bars Should produce particle of size 1 5 micron Aluminium cabinet painted with epoxy powder Piston type electric aspirator that offers high performance and great durability Protective thermal cut out relay Air delivery rate app 15 L min 24 hours continuous work for hospital use ANaAUN AW 4 System Configuration Accessories spares and consumables Technical Bidders Specs Deviation if quoted by any bidder 5 Environmental factors 95 Technical Bidders Specs Deviation if quoted by any bidder 5 1 Shall meet IEC 60601 1 2 2001 Or Equivalent BIS General Requirements of Safety for Electromagnetic Compatibility or should comply with 89 366 EEC EMC directive 5 2 The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C and relative humidity of 15 90 5 3 The unit shall be capable of operating continuously in ambient temperature of 20 30 deg C and relative humidity of 15 90 6 Power Supply Technical Bidders Specs Deviation if quoted by any bidder 6 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 7 Standards Safety and Training Technical Bidders Specs Deviation if quoted by any bidder Pl Should be FDA CE UL BIS approved product 96 7 2 Manufacturer should have ISO certification for quality standards 1 3 Comprehensive training for lab staff and support
12. should offered Digital display of compression force and compression thickness should be available 84 3 2 X Ray Generator and Tube The X ray generator should be high frequency with the following parameters kV range at least 25 35 kV in steps of 1 kV mAS range 0 750 mAS or more Exposure time 0 700ms Maximum mA 180mA or more X Ray tube unit Dual focus rotating anode tube with the following parameters focal spot size 0 1mm and 0 3mm Anode heat storage 150 kHU or more Tube heat Storage 1 3MHU or more Anode material Molybdenum and Tungsten preferred Please mention the filter material used in the tube 3 3 Flat Panel Detector Type of detector Amorphour selenium 85 preferred Detector size 24cmx29cm or more with two image formats Pixel size 70u or less Image matrix in pixels large size 3Kx 4K or more Small size 2Kx 3K or more 3 4 Workstation for image Acquisition The workstation should enable immediate image display for general survey for patient positioning It should be able to store around 10000 images The networking should on TCPIP protocol The following image processing should be possible on the workstation Image display Freely selectable screen layout Windows settings contrast and brightness setting Magnification stepped and dynamic zoom Image inversion black white 86
13. 1 1 Hydraulic operating Tables are simple tables for performing surgical procedures and it works without electrical power 2 Operational Requirements Technical Bidders Specs Deviation quoted by if any bidder 2 1 OT Table is required for general surgery and should have X Ray transluscent tops 3 Technical Specifications Technical Bidders Specs Deviation quoted by if any bidder 66 3 1 1 Four section table top with divided foot section 2 Table top should be constructed from a high pressure laminate to permit x ray penetration and fluoroscopy 3 All table positioning i e height back section lateral tilt trendelenburg and anti trendelenburg except foot and head section should be operated hydraulically 4 Should have a manual position selector whose location should be interchangeable between foot and head end 5 The casings on the frame and centre supporting column should be made of hygienic stainless steel 6 Mattress should be radio lucent and suitable for fluoroscopy 7Measurements all dimensions are approximated to _ 10 variations Height 730 1040 mm Side tilt 15 degrees Back section adjustment 15 degrees to 70 degrees Foot section adjustment 90 to 0 degree detachable Trendelenburg 25 degree Anti trendelenburg 25 degree g Head section adjustment 40 to 30 degree detachable h Maximum width 555 mm approx i Length 1950 mm approx mo Qoao eyw 4 System
14. 1 16 inch Measure W x H x D 1103 x 169 x 402 mm 43 4 x 6 7 x 15 8 inch approx Net weight 3 8 kg 8 3 lbs Functions lying measurement CE CE 0123 approved 31 Instrument Trolley SS Instrument Trolley 75 Technical Specifications Stainless steel hospital dressing and instrument trolley using for carrying dirty clothes and also can carry instruments Stainless steel hospital dressing and instrument trolley is a standard item used in hospitals SS trolley is with brakes 1 It is made of stainless steel 2 one handles two sides with rails 3 Sizes are adjustable 4 four wheels two with brakes Any additional features may be mentioned i int terms Standard Warranty Panasonic Coral or equivalent make Digital EPABX Model name to be mentioned for 15 intercom lines Complete call accounting Call forwarding Auto call Back With 15 extensions After sales service with Log book and contact of Service centre is must Product to be European CE or USFDA certified To provide manual and Service and spares details 76 Warranty Standard warranty 33 Intercom40 lines Panasonic Coral or equivalent make Digital EPABX Model name to be mentioned for 40 intercom lines Complete call accounting Call forwarding Auto call Back With 40 extensions After sales service with Log book and contact of Service centre is must Product to be European CE or USFDA certified To provide manual and Service and spares deta
15. 285mm 10mm without collar amp circular Bottom of about 230mm 10mm Height 290mm 10mm with suitably designed foot operated lid and proper handles for lifting the bin SS pipe wire rod used for cage handle and for operation of lid shall not be less than 4mm dia SS rod SS Square hollow pipe 2 Nos of 20x20 mm shall be provided at the bottom for steady placement of the bin DIMENSIONS SS pipe wire rod shall be not less than 4 mm dia WORKMANSHIP amp FINISH As per IS 3730 1988 for HDPE LLDPE bin SS parts shall be smooth finished proper rubber studs shall be provided on the paddle and both ends of 20mm SS square hollow pipe Lid of the Bin shall be foot operated and SS bottom rod of foot operated mechanism shall be minimum 8 mm It shall close to secure infected contents immediately upon releasing pressure Other requirements as per IS 3730 1988 REQUIREMENTS Bin shall be preprinted as per requirements of Bio Medical Waste Management Rules 1998 amended till date Material used shall preferably match all requirements under relevant IS code Ready to use Each Bin shall be Marked Rajasthan Health Systems Development MARKING Project Govt of Rajasthan Properly labeled Bin to indicate Product Name Produced by Address 157 Date of Manufacturing Size Batch Number Also refer IS 3730 1988 PACKING
16. 38mm wide x 49mm deep total length 28cm Small 20mm wide x 28mm deep amp 28mm wide x 36mm deep total length 26 cm Bladder Retractor KOCHER 80x65mm wide 25cm length Operating Scissors Curved Blunt Pointed Mayo 17 cm Operating Scissors Straight Blunt Pointed Mayo 17 cm Scissors Straight MAYO Blunt Blunt pointed 23 cm Suction Nozzle Suction Tube Yankauer 23 cm long 23 French Gauge 8mm dia removable tip and tubing connector Babcock Forceps SS Dressing Tissue Forceps 18 cm one each of toothed 1x2 teeth and non toothed Dressing Tissue Forceps 25 cm one each of toothed 1x2 teeth and non toothed Intestinal Tissue Forceps ALLIS 19 cm 4x5 teeth multiple ratchet used to grip arteries and digestive tissues Uterine Haemostasis Forceps GREEN ARMITAGE 21 cm Warranty 3 years 20 2 sets 1 set European CE or USFDA From Bodies Notify under directive 93 42 EEC Medical Devices With High Quality Stain less steel Grade 410 amp 420 amp should have catalogue Number article number and country of origin manufacturer engraved on each instruments should have repair center service center in India See instructions on instruments on page 1 amp 2 8 Ceiling mount LCD Projector Equipment Specifications for LCD Projector 1 Description of Function Sl Name Technical Bidders Specs Deviation if quoted by any bidder 1 1 System is required for projection of Video Signals
17. Bin shall be Marked Rajasthan Health Systems Development MARKING Project Govt of Rajasthan Properly labeled Bin to indicate Product Name Produced by Address Date of Manufacturing Size Batch Number Also refer IS 3730 1988 154 Each Bin shall be packed in poly film bag to reach destination PACKING amp PACKAGING securely Also refer IS 3730 1988 SPECIFICATION OF Plastic Bins Black Small Appendix S 4 NS 12 MATERIAL Plastic HDPE LLDPE bins made from virgin polymer material thickness of Bins bin shall be minimum 2 5 mm 0 2 mm with foot operated lid and handles for lifting also refer IS 3730 1988 for details Lid mechanism shall be of SS material only CLASS amp SIZES SMALL 15 Lt HDPE bucket of Circular Top of about 285mm 10mm without collar amp circular Bottom of about 230mm 10mm Height 290mm 10mm with suitably designed foot operated lid and proper handles for lifting the bin SS pipe wire rod used for cage handle and for operation of lid shall not be less than 4mm dia SS rod SS Square hollow pipe 2 Nos of 20x20 mm shall be provided at the bottom for steady placement of the bin DIMENSIONS SS pipe wire rod shall be not less than 4 mm dia WORKMANSHIP amp FINISH As per IS 3730 1988 for HDPE LLDPE bin SS parts shall be smooth finished proper rub
18. Configuration Accessories spares and consumables 4 1 4 2 System as specified Accessories should include a Padded arm rest with straps pair with damps b Anesthesia screen with clamps c Side supports pair with clamps 67 Technical Specs quoted by bidder Bidders Deviation if any d Shoulder supports pair with clamps e Knee crutches pair with damps f X ray cassette tray g Kidney bridge h SS bowl with clamps i Infusion rod with clamp 5 Environmental factors Technical Bidders Specs Deviation quoted by if any bidder 5 1 The unit shall be capable of being stored continuously in ambient temperature of 0 50 deg C and relative humidity of 15 90 5 2 The unit shall be capable of operating continuously in ambient temperature of 10 40deg C and relative humidity of 15 90 6 Power Supply Technical Bidders Specs Deviation quoted by if any bidder 7 Standards Safety and Training 68 Technical Bidders Specs Deviation quoted by if any bidder eet Should be FDA CE UL approved product TaZ Manufacturer should be ISO certfied for quality standards 7 3 Should have local service facility The service provider should have the necessary equipments recommended by the manufacturer to carry out preventive maintenance test as per guidelines provided in the service maintenance manual 7 4 Comprehensive warranty for 3 years 8 Documentation Technical Bidders Spe
19. Deviation if quoted by any bidder ICU Ventilator 01 Adult and Paediatric autoclavable silicone breathing circuits 02 ea Reusable Masks Small Medium Large with each machine 02 sets ea Medical Air Compressor Humidifier Servo controlled with digital monitoring of inspired gas temperature complete with internal heating wire O1 Filter paper for humidifier for 100 uses 01 Environmental factors SI Sel 5 2 5 3 Name Technical Bidders Specs Deviation if quoted by any bidder The unit shall be capable of being stored continuously in ambient temperature of 0 50 deg C and relative humidity of 15 90 Shall meet IEC 60601 1 2 2001 Or Equivalent BIS General Requirements of Safety for Electromagnetic Compatibility The unit shall be capable of operating continuously in ambient temperature of 10 40deg C and relative humidity of 15 90 134 6 Power Supply Technical Bidders Specs Deviation if quoted by any bidder 6 1 Power input to be 220 240VAC 50Hz 6 2 Resettable overcurrent breaker shall be fitted for protection 7 Standards Safety and Training Technical Bidders Specs Deviation if quoted by any bidder 7A Certified to be compliant with ANS IEC60601 2 12 01 Medical Electrical Equipment Part 2 12 Particular Requirements for the Safety of Lung Ventilators Critical Care Ventilators 7 2 Should be FDA and European CE approved product 13 Certified to be compliant with IS
20. Hegar Straight SS 0 0 0 0 100 0 100 1000 84 Retractors Doyens Big SS 0 0 0 0 100 0 100 2000 85 Retractors Doyens Small SS 0 0 0 0 100 0 100 2000 86 a ahaa curved blunt pointed 0 0 0 0 ae 0 100 ania 87 i a straight blunt pointed 0 0 0 0 Pe 0 100 iod 88 Scissors Straight Mayo Blunt 23 cm SS 0 0 0 0 100 0 100 1000 89 Scissors Straight Mayo Blunt pointed 23 cm SS 0 0 0 0 100 0 100 1000 90 Suction Nozzle small 0 0 0 0 100 0 100 1000 91 Suction Nozzle medium 0 0 0 0 100 0 100 1000 92 Suction Nozzle large 0 0 0 0 100 0 100 1000 93 Suction Tube Yankauer 23cm 0 0 0 0 100 0 100 1000 94 Intestinal Clamps Curved Dry Pattern 23cm SS 0 0 0 0 100 0 100 1000 95 Intestinal Clamps Straight Dry Pattern 23cm SS 0 0 0 0 100 0 100 1000 96 Dressing Forcep Tissue 18cm Toothed SS 0 0 0 0 100 0 100 1000 97 Dressing Forcep Tissue 18cm On Toothed SS 0 0 0 0 100 0 100 1000 100000 98 Dressing Forcep Tissue 25cm Toothed SS 0 0 0 0 100 0 100 1000 99 Babcock forcep 20cm SS 0 0 0 0 100 0 100 1000 100 Allis Forcep 20cm SS 0 0 0 0 100 0 100 1000 101 i i i Utering Haemostatic forcep Green Armitage 21 0 0 0 0 0 100 Jado cm SS 100 102 Hystrectomy forcep curved HEANEY 23 Cm SS 0 0 0 0 100 0 100 1000 103 Hystrectomy forcep curved MOYNIHAN 23 Cm SS 0 0 0 0 100 0 100 1000 104 Hystrectomy forcep straight toothed WERTHEIM 000 24 Cm SS o 0 100 0 uae i 105 H f hed WERTHEIM ystrectomy forcep On toothed 24 0 0 0 0 0 1
21. Overall approx size Top 280mm x 280mmx Ht 445mm 81 Construction The top should be made up of 304 grade stainless steel sheet 0 9mm thick double press bent on four sides The edges of the stainless steel sheet should be folded to 180 degree to avoid the sharp edges Frame Work the frame should be made up of 25mm x 25mm x 1 2mm thick CRCA square tubes for vertical members and the horizontal members should be made up of 19mm dia x 1 2 thick CRCA tubes The stainless steel top should be fixed with the help of pop refits in slush position The heavy duly insertable plastic shoes should be provided Finish All components should be pretreated in separate eight tank process for better finish good adhesion and corrosion protection Process includes hot degreasing Derusting activation Phosphating amp No s of water rinses as per IS 3618 1966 class C type and then pretreated materials is coated with epoxy powder with film thickness of 60 microns approx and than oven backed at 180 degree centigrade TECHNICAL SPECIFICATIONS OF DIGITAL MAMMOGRAPHY SYSTEM For all the above specifications please mention the parameters that are offered by you as against the requirement The entire system should be FDA approved including the biopsy system S N Description of function Complies Yes NO 1 1 Mammography system to replace conventional Film Screen based Mammography Studies with digital images instant 82 reviewin
22. be provided to drive all loudspeakers during an emergency without overloading Each power amplifier shall have a built in self restoring protection circuit to guard against hazards of operation such as mis loading at its input short circuiting of its output and connection mistakes The power amplifiers shall also have built in line transformers for 100V loudspeaker matching DC input of emergency operation It shall have amplifier monitoring and auto changeover over circuits amp automatic volume control features built in The power amplifiers shall have control inputs and audio inputs for interfacing for fire alarm signals This control inputs shall be supervised freely programmable for any system actions and with priorities setting A built in amplifier monitoring circuits shall continuously monitor the functioning of the power amplifiers and shall automatically switch in a spare power amplifier in case of failure of any of the amplifiers Upon detection the status of the fault shall be indicated in the Central or local Monitoring The number of spare power amplifiers to be provided shall be ten percent of the total quantity of each range of power amplifiers All speaker lines shall be supervised for open circuit fault short circuit fault and short to ground fault Upon detection the status of the fault shall be indicated in the Central Monitoring The loudspeakers shall be located such that they meet the necessary requirements Rooms with on off
23. control spin cancellation approx dimensions WxDxH 598x550x844 Power requirement 220 V Energy efficient A rating Voltage Volts 220 240 Power Consumption Wash Motor Cold Watts 2000 Power Consumption Wash Motor Hot Watts 2400 Power Consumption Spin Motor Watts 500 145 Loading Top loading heavy duty After Sales Service Warranty Period 3 years 3years CMC 3 years Warranty 3 Years CMC Industrial Grade Drying Machine Capacity of drying 7 10 kg clothe cycle Capable of running for multiple cycles day Load detection should be automated Should have 100 drying effect Should be uniform drying of clothes Should be odor free drying Time adjustment is self mechanized Low noise Should get high performance per watt Power supply a Power input should be 220 240VAc 50Hz b b Voltage corrector stabilizer of appropriate ratings meeting ISI specifications input 160 260V and output 220 240V and 50Hz c Standards safety and training a It should be a safety certified approved product 146 b Manufactures suppliers should have ISO certificate to Quality Standard Documentation a User Technical Maintenance manuals to be supplied should be in English b b List of important spare parts and accessories with their part number and costing Maintenance and Warranty a Training and installation at end user site Proposal for full warranty up to three years from the date of insta
24. e Resolution 1 BPM e Accuracy E 1 7 Alarms Audio Visual Hi Lo diteh of the sound changes with the change of Spo2 pulse e High SpO2 70 to 111 98 e Low Sp02 30 to 98 e High pulse 80 to 250 bpm e Low pulse 20 to 150 bpm 8 Mode Real time average of 15 sec 20sec amp 30sec 9 Tubular Trends memory up to 72 hrs E 7 10 Time Scale 5sec to 5min programmable E 11 Graphical Trend Memory 24hrs 5sec to 5min Programmable 12 Sequence Data Memory 100 Test data F 13 Pulse Amplitude 12 segment bar graph 7 14 Output Rs 232 E 15 Display Type Led Red Yellow 16 Additional Features if any 17 Name of the manufacturer 112 Model No Warranty terms 3 years Warranty and 3 years CMC 50 Pulse Oxymeter With Neonatal Probe Pulse Oxymeter With Neonatal Probe SPECIFICATIONS FOR NEONATAL PULSE OXYMETERS 1 Method Dual wavelength LED 2 Oxygen saturation Range 0 99 Resolution 1 Accuracy 2 at 70 99 range 3 at 40 70 range Averaging time selectable 3 21 secs Search time selectable 10 40 sec Sensors Re usable finger probe Re usable flexible multi site probe 3 Pulse rate Waveform Plethysmographic or bar form Range 20 250 bpm Resolution 1 bpm Accuracy 2 bpm 4 Display Saturation Pulse Rate Waveform Alarms 113 4 Alarms High SpO2 Low SpO2 High pulse Low pulse 5 Trends Memory Data interval Display 6 Power 7 Accessor
25. from LCD Monitor on to wall screen or Large Video Screen 2 Operational Requirements Technical Bidders Specs Deviation if quoted by any bidder 21 2 1 Universal compatible system is required 3 Technical Specifications Technical Bidders Specs Deviation if quoted by any bidder Specifications LCD Projector DnuKRWNF Screen Size 4 meters diagonally Aspect Ratio 4 3 Computer Compatibility VGA SVGA XGA SXGA Video Compatibility PAL SECAM NTSC Projection Lamp UHP METALHALIDE NSH LAMP Details of lamp to be furnished in the offer Lamp Life 2000hrs Minimum If offered models are with lamp life less than 2000 hours additional lamps to achieve lamp life 2000 hrs Minimum Ja 8 9 10 11 12 13 14 T5 16 17 18 19 20 21 Lamp hour counter To be built in Brightness 2000ANSI Lumens or higher Throw Distance Range Should cover 2 meters 5 meters from screen Audio System Minimum 1 0 watt RMS with built in speaker Zoom Focusing Lens Zoom 1 1 2 or higher Motorized Zoom amp Focus Controlled by a Remote Remote Control Remote control unit for PC and Mouse with inbuilt laser pointer Terminals ports with connectors Input output Video IN S Video IN RGBIN Audio IN RGBOUT connectivity for remote mouse to be specified by bidder Power Consumption 260 W Max to be specified by bidder Contrast Ratio 260 I or higher PCMCIA card slot
26. mask type resuscitation Peak Inspiratory Pressure PIP control valve to adjust the maximum Inspiratory pressure delivered to baby Positive End Expiratory Pressure PEEP control valve to maintain minimum positive pressure at the end of expiration to keep the lungs inflated Overall control over system by setting Maximum Pressure Relief to the system Warranty 3 years with 3 years CMC 17 7 C aserean Section Instruments Set Please See detailed specification for instruments in page 1 amp 2 Item description QUANTITY PACK 18 L S C S Pack Instrument Tray with cover Stainless steel 300x 200 x 65 Towel Clips Backhaus 13cm Sponge Holding Forceps Forester Straight serrated 25cm Artery Forceps Straight CRILE Small 14 cm Halstead Mosquito Forceps 12 5 cm Tissue Forceps 18 20 cm Needle Holder Mayo Hegar Straight 18 cm Surgical Knife Handle one each of No 3 and 4 to be used with surgical blades sizes 20 21 22 23 and No 4 to be used with blade sizes 10 11 12 and 15 Abdominal Retractor size 3 Abdominal Retractor Double Ended Richardson Eastman set of two stainless steel blades Large 49mm wide x 63mm deep amp 38mm wide x 49mm deep total length 28cm Small 20mm wide x 28mm deep amp 28mm wide x 36mm deep total length 26cm Abdominal Retractor Double Ended Richardson Eastman 19 2 sets 1 set set of two stainless steel blades Large 49mm wide x 63mm deep amp
27. mm shall be DIMENSIONS provided at the bottom for steady placement of the bin SS pipe wire rod shall be not less than 4 mm dia WORKMANSHIP amp FINISH As per IS 3730 1988 for HDPE LLDPE bin SS parts shall be smooth finished and powder coated proper rubber studs shall be provided on the paddle and both ends of 20mm SS square hollow pipe REQUIREMENTS Lid of the Bin shall be foot operated and SS bottom rod of foot operated mechanism shall be minimum 8 mm It shall close to secure infected contents immediately upon releasing pressure Other requirements as per IS 3730 1988 152 Bin shall be preprinted as per requirements of Bio Medical Waste Management Rules 1998 amended till date Material used shall preferably match all requirements under relevant IS code Ready to use Produced by an ISO 9001 2000 Certified Unit MARKING Each Bin shall be Marked Rajasthan Health Systems Development Project Govt of Rajasthan Properly labeled Bin to indicate Product Name Produced by Address Date of Manufacturing Size Batch Number Also refer IS 3730 1988 PACKING amp PACKAGING Each Bin shall be packed in poly film bag to reach destination securely Also refer IS 3730 1988 SPECIFICATION OF Plastic Bins Red Small Appendix S 4 NS 11 MATERIAL Plastic Bins HDPE LLDPE bins made from virgin p
28. of 15 90 5 3 Thu unit shall be capable of operating in ambient temperature of 20 30 deg C and relative humidity of less than 70 6 Power Supply SI Name Technical Specs Bidders Deviation quoted by bidder if any 6 1 Power input to be 220 240VAC 50Hz 6 2 UPS of suitable rating shall be supplied for minimum 1 hour backup for the entire system 7 Standards Safety and Training SI Name Technical Bidders Specs Deviation if quoted by any bidder 7 1 Certified for meeting IEC 60601 1 4 Medical electrical equipment Part 1 4 General requirements for safety Collateral Standard Programmable electrical medical systems 7 2 Attach original manufacturer s product catalogue and specification sheet Photocopy computer print will not be accepted All technical data to be supported with original product data sheet Please quote page number on compliance sheet as well as on technical bid corresponding to technical 123 specifications 7 3 Electrical safety conforms to standards for electrical safety IEC 60601 IS 13450 7 4 Should be FDA US CE approved product Warranty terms 3 years Warranty and 3 years CMC 54 Servo Controlled Online Voltage Stabilizer Specify150 KVA as per load properly distributed so that sensitive sensors of SNCU are not affected High speed electro mechanical regulators that provide constant voltage by Dsing a variac along with a buck boost transformer makes a servo stabilizer These are idea
29. services till familiarity with the system 7 4 Comprehensive warranty for 3 years and 3 years CMC after warranty including UPS Documentation SI Name Technical Bidders Specs Deviation if quoted by any bidder 8 1 User Technical Maintenance manuals to be supplied in English 8 2 List of important spare parts and accessories with their part number and costing 8 3 Compliance Report to be submitted in a tabulated and point wise manner clearly mentioning the page para number of original catalogue data sheet Any point if not substantiated with authenticated catalogue manual will not be considered 8 4 List of Equipments available for providing calibration and routine Preventive Maintenance Support as per manufacturer documentation in service technical manual 8 5 Certificate of calibration and inspection 8 6 Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job descriptin of the hospital technician and company service engineer should be clearly spelt out 97 43 O2 cylinder with instrument set for Boyles B Type capacities Technical Specifications for Oxygen medical grade in three type of capacities of cylinders Oxygen e Should be certified for medical use as per IP 1996 Should not contain less than 99 5 V V of Oxygen not more than 5 PPM V V of carbon monoxide and not more than 300 PPM V V of carbon dioxide e Should be free of halogens oxidizing substances e Water co
30. the system shall be capable of delivering a sound pressure level of 85 dB at the listening level For M amp E areas such as plant rooms etc where the noise level is higher assumed to be lt 80 dB the system shall be able to deliver 95 dB at the listening level The listening level shall be taken to be 1 5 m above floor level The reinforced sound shall be distributed evenly throughout the listening area the total variation in each area shall not exceed 4 dB 107 An articulation loss of consonants of less than 15 shall be maintained Generally the reverberation time of the various locations shall be assumed to be not more than 1 9 seconds Paging announcements shall be possible from any of the microphone call stations or from the microphone paging station to any zones within the network systems Call station shall be using CAT 5 cable with RJ 45 connector to transmit calls The microphone paging station shall have the flexibility of selecting any number of user keys selection buttons at any one time It shall be able to program each user key for function The central controller shall have a means of monitoring to continuously monitor the system from the microphone of the call station onwards any faults shall be displayed on the central unit High quality signals shall be maintained at the output of the power amplifiers to compensate for losses in the audio distribution lines Each power amplifier with 30 spare capacity shall
31. volume control units as required are indicated in the schedule of tables Facilities shall be incorporated to override these volume control units including those in the off position to enable emergency announcements to be broadcast In general one ceiling speaker shall be provided for every 25 square meters in each room such as offices and corridors while a minimum of one ceiling speaker shall be provided for areas less than 25 square meters such as booths pantry and toilets Horn speakers shall be provided for all plant rooms generator rooms and outdoor areas with high ambient noise The system shall also have the means to cut off the music sources during emergency paging and shall enable the emergency announcement to be heard in these areas All volume controls as specified shall be overridden during emergency announcements There shall be background music to selected areas It shall be possible to pre program any of the output music to any of these zones Sources provided shall be a continuous cassette player MP3 an integrated compact disc player with digital tuner All equipment such as the central network controller and power amplifiers shall be housed in 19 inch equipment racks 3 POWER AMPLIFIERS It shall meet the following minimum requirements 108 The main function of the power amplifier is the amplification of audio signals for the loudspeakers It shall be possible to select the output voltage between 100V 70V or 50V by cha
32. which links one or more cameras to a digital video recorder It s main advantage is that it can record for much longer periods without the need to change tapes The technology also means it is possible to review footage immediately while continuing to record Technical Specifications of DVR Main Processor High Performance Embedded Microprocessor Operation System Embedded Linux OS 116 Signal System System Resource Operation Interface Video Split Video Playback Resolution Bit rate Control Image Control Recording Speed Video Display Resolution Motion Detection Audio Compression Recording mode Recording Prioritys Playback PAL NTSC Recording Playback Remote Access Front Touch Panel Mouse Remote 1 4 9 Split Display 2 Channel D1 and 6 Channel CIF Dual stream 6 Levels PAL 25fps channel NTSC 30fps channel PAL 720X576 fps Configurable detection areas G 711 Manual schedule sensor motion detection Manual gt Alarm gt Motion Detection gt Schedule Single Channel 8 channel Simultaneous 117 Playback Search Video Storage Backup Mode Video Input Video Output HDMI Output Audio Input Audio Output Ethernet Interface PTZ Interface USB Interface HDD SATA Interface DVDRW Back Mode Protocol Date Time Event Channel Local HDD USB DVDRW 8 ch BNC 1 0 p p 75 ohm 1 BNC 1VGA 800x600 1024x768 Network Yes 4 cha
33. 00 ine Cm SS 100 106 Right angle retractor SS 0 0 0 0 100 0 100 1000 107 Devers retractor SS 0 0 0 0 100 0 100 1000 Estimated Value in Rs 1 Split Air Conditioner 1 5 Tonne 1 1 5 ton 5 star Split Air Conditioner with voltage stabilizer 2 Nominal Capacity 1 5 ton 3 Electricity in put 230V 50Hz Single Phase 4 Coefficient of performance 3 Minimum 5 Noise level 6 Indoor unit Less than 45 db 7 Outdoor unit Less than 55 db 8 Function modes Auto Cool Fan Dry shall have sleep and power saving mode 9 Other features Automated vertical swing for horizontal louvers antifreeze thermostat 10 Compressor Rotary type 11 Body surface finish powder coated high quality paint finish 12 Air filtering unit Activated carbon cartridge dust proof and anti bacteria filter 13 Length of tubings 20 ft Please quote per ft rate of copper tubing in case of site requirement is more than 20 ft 14 Remote handset LCD display with night glow 15 Voltage Stabilizer Stabilizer having ISI quality certification and power rating that matches with the power rating of the AC unit Warranty 3 years and CMC thereafter of 3 years 2 Almarih Steel Almirah Approx Size 1980mm H x900mm W x480mm D mm 10 Sheet thickness Approx 22 guage prime CR Sheet for body and body and Approx 20 gauge for doors The Almirah should have four shelves making five compartments of standard size The Almi
34. 2 3 13 3 14 3 15 3 16 3 17 3 18 c Spontaneous Breathing trial d Facility to calculate lower and upper inflection point Nebuliser with capability to deliver particle size of lt 3 micron amp to be used in both Off and On line Automatic Patient Detection facility preferable Medical Air Compressor a Imported stand alone Medical Air compressor from same manufacturer pf ventilator b Snap fit with the Ventilator module to provide an oil free Medical air c Peak output flow should be minimum 160 LPM d Air quality should comply with ISO compressed air purity class e Medical Air Compressor should automatically activate in the event of wall air supply loss f Replacement of internal filters should be performed without removing the compressor g Should have washable air filter Technical Specifications for reusable face mask amp nasal mask Reusable face amp nasal mask with textured dual flap silicone cushion flap for easy fit Removable forehead support and pad to match the angle of patient s forehead Stability Selector for easy fit and angle Ball amp Socket headgear attachments Should be autoclavable Battery back up for minimum 30 minutes for ventilator RS 323C interface for communications with networked devices Automatic patient detection facility preferable 4 System Configuration Accessories spares and consumables 133 4 1 4 2 4 3 4 4 4 5 4 6 Technical Bidders Specs
35. 327 3 8 3 9 Should have four section mattress base Should have X Ray translucent back section made up of high pressure laminate Should have X Ray cassette holder underneath the back section amp should allow insertion of X Ray cassette from either side of the bed Base frame amp support frame should be made up of steel for long life amp prevention from rusting Should have stepless electrical adjustment for the following Height 450 840 mm Back section 0 50 degrees Leg Section 0 30 degrees Should have stepless pneumatic adjustment for Trendlenburg 25 approx anti trendlenburg 15 approx Should have a manual quick release mechanism for back section adjustment during emergency situation Should be equipped with four articulated half length tuck away side rails Should be equipped with large castors diameter 150 mm with central braking and steering facility 71 Technical Specs quoted by bidder Bidders Deviation if any 3 10 Mattress of the Bed should be made up of high density foam with Anti Microbial agent incorporated into all components that assists in Prohibiting growth of bacteria amp fungi and easy to clean 3 11 Mattress should be fully Radiolucent for ease in performing portable X Rays 3 12 Should have bumpers at all four corners and place for fixing accessories 3 13 Dimensions of bed Length 2200 2290 mm approx Width 850 1020mm approx Mattress Size appropriate as p
36. 4 Trending facility for minimum 48hours with minimum 5 minutes resolution for recent 24 hours 3 5 Automatic compliance amp Leakage compensation for circuit and ET tube 3 6 Following settings for all age groups a Tidal Volume b Pressure insp c Pressure Ramp d Respiratory Rate 131 e SIMV Respiratory Rate f CPAP PEEP g Pressure support h FIO2 i Pause Time j Pressure amp Flow Trigger 3 7 Monitoring of the following parameters a Airway Pressure Peak amp Mean b Tidal volume Inspired amp Expired c Minute volume Inspired and Expired d Spontaneous Minute Volume e Total Frequency f FIO2 dynamic g Intrinsic PEEP and PEEPi Volume h Plateau Pressure i Resistance amp Compliance j Use selector Alarms for all measured amp monitored parameters 3 8 Modes of ventilation a Volume controlled b Pressure Controlled c Pressure Support d SIMV Pressure Control and volume control with pressure support e CPAP PEEP f Inverse Ratio Ventilation g Advanced mode like pressure controlled volume guaranteed h Non Invasive ventilation i APRV or equivalent 3 9 Apnea backup ventilation 3 10 Expiratory block should be autoclavable and no routine calibration required or with expiratory autoclavable filter In case of filter min 10 nb should be provided with the machine 3 11 Should have the ability to calculate Procedure a Intrinsic Peep amp Intrinsic PEEP Volume b Occlusion Pressure 132 3 1
37. 5 10 0 0 0 15 110000 1650000 Air Oxygen blender 162 66 T Piece resuscitator 2 4 g i 4 6 100000 oe 164 67 Cold Light Source LED 2 2 oe i oe 4 45000 1g0u00 465 68 Neo natal amp pediatric Stethoscope 15 20 0 0 0 35 10000 350000 166 Foot Step for climbing Examination table SURGICAL ITEMS EUROPEAN CE or USFDA Approved enclose a valid certificate for item 0 0 0 407 1500 1907 500 953500 quoted in SS instruments will be demonstrated 69 before technical committee to ensure the quality of instrument before opening the price bid 167 70 Anterior Veginal wall retractor SS Q o 2B 7000 eas nee azeeUe 71 Sponge Holding Forcep SS 0 0 0 515 3000 3515 1000 3515000 fe eee o o o 493 3000 3493 1000 3493000 a o o 0 3451000 Tooth Forcep SS 451 3000 3451 1000 Outlet Forcep SS 74 0 0 0 86 0 86 1000 86000 75 Cuscos vaginal speculum SS 0 0 0 0 100 1000 100000 100 76 Episiotomy Scissor SS 0 0 0 0 0 100 1000 100 17 Suture Cutting Scissor SS 0 0 0 0 100 0 100 1000 78 Kidney Tray SS 0 0 0 o 400 0 100 500 79 Towel Clips Backhaus 13 cm SS 0 0 0 0 100 0 100 200 80 Artery Forcep Straight Crile Small 14cm SS 0 0 0 0 100 0 100 1000 81 Halstead Mosquito Forcep 12 5c Straight SS 0 0 0 0 100 0 100 1000 82 Halstead Mosquito Forcep 12 5c Curved SS 0 0 0 0 100 0 100 1000 83 Needle Holder Mayo
38. 8 4 Log book with instruction for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out Should be European CE or USFDA approved 50 Item Description Four door metal storage locker a 4x4 drawer type filing office cabinet with lock and key of standard size with filing leafs within it should be vertical Steel cabinet of standard make like Godrej or equivalent registered Brand Item description Flux meter microprocessor controlled Technical Specifications 1 Measures irradiation of a Photo therapy unit in frequency range 400 500 nm 2 The meter operates in humidity range of 0 to 95 3 Mains as well as battery operated 51 4 It has a back lit clearly visible Bright display with high reading accuracy 5 Pectral Response Blue Range 400 520 nm 6 Accuracy Within 10 Application This range is widely used for measuring irradiation output level of light sources in the blue range from 400 to 520 nm of wavelength Used to measure the effectiveness of photo therapy in neonatal jaundice hyperbilirubinemia A manual with warranty card may be provided in English Service Engineer contact with visits at regular quarterly intervals for caliberation be ensured in log book provided Warranty terms 3 years Warranty and 3 years CMC Formalin chamber of Appropriate Size as used for sterlization of laparoscopes ISI
39. ANNEXURE B MATERNAL amp CHILD HEALTH EQUIPMENT SPECIFICATIONS TECHNICAL SPECIFICATIONS FOR MCH EQUIPMENTS Annexure 2 153 DP s 24maternity wards 250 New DP s 6 Medical Colleges Annexure 3 1500 SHC s Note Specifications of all major equipments given below Figures given are only illustrative only for major items it does not specify any particular company given in picture to be quoted Surgical Items and instrument sets at sr no 80 117 are not illustrated but these should be European CE or USFDA From Bodies Notify under directive 93 42 EEC Medical Devices With High Quality Stain less steel Grade 410 amp 420 amp should have catalogue Number article number and country of origin manufacturer engraved on each instruments should have repair center service center in India approved and valid certificate must be attached for item Sr no quoted by Bidder A Specification of Key Surgical Instruments Certificate of Conformity for Surgical Instruments All Surgical Instruments should be made of highest quality materials e g stainless steel S S for metal devices Verification of this will be required from manufacturers suppliers for products offered this can be done by submitting official certification that their design and production facilities are accredited to relevant quality assurance QA standards such as EN ISO 9001 and 9002 EN 46001 and EN 46002 and or Annex II of the EU Medical Products Directive 93 42 EEC which enabl
40. Annotation Left right marking Text additions Lines Rectangles and circles Measurements Distance Angle Density Image evaluation Contrast enhancement with table 87 Display of histogram Length measurements Before after comparison Filter Administration The demographic patient data should be retrieved directly from a HIS RIS system The demographic patient data can be entered manually Retrieval of images from CD DVD or PACS Printing of images on DICOM compatible printers The workstation should be fully DICOM compatible High Contrast 1Kx 1K TFT monitor should 88 be provided with workstation 3 5 Biopsy Please quote for Stereo tactic biopsy system which is fully compatible with FFDM A high resolution image of 20 1p mm should be possible with the stereo tactic biopsy system S N System Configuration Reply Comments Accessories spares and consumables 4 1 Mainframe System 01 4 2 X Ray tube Unit amp tube 01 4 3 Flat Panel Detector 01 4 4 Image acquisition Workstation01 4 5 Stereotactic Biopsy System 01 89 4 6 Archieving System 01 4 7 View Boxes slim four in one with fluorescent tubes and shutters with magnification device and variable luminescence 02 S N Environmental factors Reply Comments 5 1 The
41. Gas Stability 1 Oxygen Connection Types DISS Type Air amp Oxygen Inlets amp Outlets and or NIST Type Air amp Oxygen Inlets Dimensions without fittings Depth 4 9 in 12 5 cm Width 2 3 in 5 7 cm Height 4 1 in 10 4 cm Weight Unit Weight 2 29 Ibs 1 04 kg Shipping Weight 2 95 lbs 1 34 kg Operating Temperature Range 59F to 104F 15C to 40 Transport Storage Requirements Temperature Range 10F to 140F 23 to 60T Humidity Max 95 Noncondensing Fl0 Accuracy 3 of full scale Pressure Drop Low Flow lt 2 psi 0 14 bar at inlet pressure from 30 90 psi 2 1 6 2 bar and at 10 L min flow rate at 60 F102 High Flow lt 3 psi 0 21 bar at inlet pressure from 30 90 psi 2 1 6 2 bar and at 30 L min flow rate at 60 F102 The Air Oxygen Blender has been cleaned for Oxygen Service prior to delivery The Air Oxygen Blender reverse gas flow complies with clause 6 of ISO 11195 Analyzer should comply with ISO 21647 Dryness and Composition for inlet gases Air Medical Air supply should meet the requirements of ANSI 286 1 1973 commodity specification for Air type 1 grade D or better Oxygen Oxygen supply must meet all requirements of USP Medical Grade Oxygen ONLY for CE requirements Both inlets should remain 10 F 5 55 or more below the lowest temperature to which the air distribution system equipment is exposed At a temperature of 25F 3 9 and a pressur e of 90 psi 6 33 kg cm t
42. Instrument surfaces must NOT be stamped indented or scratched Anodised labelling is permissible It is preferred if the suppliers labelled FHD name in anodised form of labelling d Particular attention must be paid to the quality of box joints to ensure that they are smooth and interlock well and to teeth and grips to ensure that they meet and interlock accurately Finger rings must be of proper size and shape for maximum utility and comfort The inside of finger rings must be well rounded and free of sharp edges rough areas and grinding marks cracks overlaps burrs e Jaw serration must be well cut and defined and must mesh properly when the jaws are fully closed The edges of the serration must be well chamfered and must not contain burrs or sharp edges Teeth must be sharp unless otherwise specified of proper size and shape free of rough edges or burrs and must mesh with sufficient accuracy to ensure proper performance for the use intended f Ratchet and ratchet catches must be properly aligned and undercut for safe locking Ratchets must be of such design as to ensure easy and positive engagement and proper disengagement Ratchets and ratchet catches must be free of burrs and sharp edges g Locks forceps and similar instruments must be of the box lock type or lap joint type All type of locks must be accurately fitted without stiffness and without crevices burrs or sharp edges anywhere in the construction h Screws of screw lock scis
43. Main Failure 53 Sound Proof and Environment Friendly Acoustic Enclosures Canopies Countrywide service network ACCESSORIES Base frame Fuel tank Battery with leads Required Optional features required e Automatic Mains Failure Panel e Synchronizing Panel Manual amp Automatic e Soundproofing of existing D G Set Rooms e Installations Works Installation Under scope of supplier as per the checklist PRE INSTALLATION CHECK LIST Customer Name DG Set Rating 10 Genset Location Location Ground Level Basement First Second Roof top Acoustic enclosure Ensure natural wind flow does not cause restriction to air outlet from radiator if so provide barrier 54 Genset should be located away from dusty atmosphere acidic fumes dust fibers chemical etc Copy of Installation Bulletin available with customer 20 Room layout Size Length Breadth Height For multiple sets ensure minimum distance between DG GG sets as per guidelines Proper amp sufficient openings in engine room for ventilation as per guidelines Arrangement for Unloading Placement of Genset 30 Room Ventilation Recommended openings for radiator cooled engines Actual size at Front Rear Provision for forced ventilation in HE cooled engines 40 Foundation Size Length Breadth Height DG GG Set placement provides area for service personnel to move around the DG GG set 50 Air system 55 Heavy duty air
44. O 7767 for Oxygen monitoring 7 4 Should meet IEC 529 Level 3 IP3X spraying water for enclosure protection water ingress 7 5 Demonstration of quoted equipment whenever asked for 135 7 6 Should have local service facility The service provider should have the necessary equipments recommended by the manufacturer to carry out preventive maintenance test as per guidelines provided in the service maintenance manual 7 7 Comprehensive warranty for 3 years and provision of CMC for next 3 years 7 8 Back to back warranty to be taken by the supplier from the principal to supply spares for a minimum period 10 years 8 Documentation Technical Bidders Specs Deviation if quoted by any bidder 8 1 Certificate of calibration and inspection from factory 8 2 List of Equipments available for providing calibration and routine maintenance support as per manufacturer documentation in service technical manual 8 3 User Manual in English 8 4 Service manual in English 8 5 Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job descriptin of the hospital technician and company service engineer should be clearly spelt out 8 6 List of important spare parts and accessories with their part number and costing 8 7 Compliance Report to be submitted in a tabulated and point wise manner clearly mentioning the page para number of original catalogue data sheet Any point if not substantiated with authe
45. R DOUBLE PURIFICATION BY RO UV UF WITH TDS CONTROLLER SHOULD REMOVE DISSOLVED IMPURITIES WHILE RETAINING ESSENTIAL MINERALS CERTIFICATIONS LIKE NSF or EQUIVALENT BE ENCLOSED COMPUTER CONTROLLED OPERATION WITH FILTER CHANGE AND UV FAIL ALARMS HIGH POWER 11W UV LAMP FOR COMPLETE DEACTIVATION OF HARMFUL MICROORGANISMS Should be fully Automatic with AUTO START AND AUTO OFF BUILT IN SMPS THAT SUPPORTS WIDE RANGE OF INPUT VOLTAGE 100 300V AC RO membrane should be of latest technology 163 Auto on and off controls Operating Power 230v 10 to 10 at 50 Hz Warrantee 3 years warrantee Warranty Terms 3 years warrantee amp CMC contract form with charges from Year 4 6 65 Air Oxygen Blender Primary Outlet Flow Range 3 30 L min With supply pressures at 50 psi 3 4 bar with BLEED closed Auxiliary Outlet Flow Range 0 30 L min With supply pressures at 50 psi 3 4 bar with BLEED closed Bleed Flow 3 L min or less at 50 psi 3 4 Maximum Combined Flow All Outlets 2 30 L min Bypass Flow Loss of Air or Oxygen Supply 2 45 L min Bypass Alarm Activation 50 psi 3 45 bar 18 22 psi 1 2 1 5 bar 60 psi 4 14 bar 16 24 psi 1 1 1 65 bar 164 Alarm Reset When pressure differential is 6 psi 0 4 bar or less Alarm Sound Level 2 to 80 db at 1 ft 0 3 m Oxygen Concentration Adjustment Range 21 100 Gas Supply Pressure 30 75 psi 2 1 5 2 bar Air and Oxygen within 10 psi 0 69 bar of each other Mixed
46. aining Sl Name Technical Bidders Specs Deviation if quoted by any bidder 7s System should confirm to 1S 6365 1971 Reaffirmed 1995 with latest amendments in ISI specifications for Laboratory Electric Ovens Alternatively system should be FDA Approved or CE Certfied 64 7 2 133 Electrical safety conforms to standards for electrical safety IEC 60601 IS 13450 Should be compliant to ISO 13485 Quality systems Medical devices Particular requirements for the application of ISO 9001 applicable to manufacturers and service providers that perform their own design activities 8 Documentation Technical Bidders Specs Deviation if quoted by any bidder 8 1 8 2 8 3 8 4 8 5 User Technical Maintenance manuals to be supplied in English Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job descriptin of the hospital technician and company service engineer should be clearly spelt out List of important spare parts and accessories with their part number and costing Certificate of calibration and inspection List of Equipments available for providing calibration and routine maintenance support as per manufacturer documentation in service technical manual Warranty 3 years and 3 years CMC 65 Equipment Specifications for OPERATION TABLE HYDRAULIC 1 Description of Function SI Name Technical Bidders Specs Deviation quoted by if any bidder
47. alth PICU SNCU Ward Wing 2 Ann3 Total Cost Value in Rs Page 1 Air Conditioner 1 5 Tonne Split 12 21 0 0 0 0 33 39000 1287000 9 2 Almari Steel Almirah steel Linen Almirah Medicine Almairah Almirah for drug i 2 Hl j ee 9 ae TODD 1713009 11 3 Audio system for ICU Amplifier 0 0 0 1 0 0 1 15000 15000 11 4 Basin Stand Assorted SS 0 0 0 n 0 0 n 650 46800 13 5 BP apparatus stand model 0 0 o 20 0 0 20 1700 34000 14 6 Bubble C PAP 0 4 0 0 0 0 4 150000 600000 15 7 Caesarean Section Instruments Set 0 0 0 7 74 0 81 30000 2430000 15 i Ceiling mount LCD Projector 0 0 0 2 4 0 6 65000 390000 19 9 Central Monitoring System 0 0 0 1 0 0 1 60000 60000 23 10 Chair Doctor amp Sister chair 8 20 10 110 31 0 148 13200 1953600 39 TI f f Computer with Modem with UPS Printer with 1 1 0 9 0 0 11 35000 385000 Internet connection 31 12 Diet trolley stainless steel 0 0 0 25 0 0 25 800 20000 35 13 Doctor amp Sister Table o 0 10 45 0 Oo 55 3500 192500 36 14 Double Outlet Oxygen Concentrator 10 20 0 0 0 0 30 30000 900000 37 15 Double Sided Light Phototherapy LED type 0 6 0 0 0 0 6 32000 192000 37 Electrically Operated Pressure Controlled Slow 16 Suction Machine 5 20 0 0 0 0 25 5000 125000 41 17 Emergency resuscitation kit adult amp paed 0 0 0 7 0 0 7 2000 14000 42 18 Enema Set 0 0 0 7 0 0 7 100 700 43 a E
48. ation vii Error indicator viii ID DISPLAY LED LCD ix Redialing facility 4 System Configuration Accessories spares and consumables SI Name Technical Bidders Specs Deviation if quoted by any bidder 4 1 All consumables required for installation and standardization of system to be given free of cost 5 Environmental factors Sl Name Technical Bidders Specs Deviation if quoted by any bidder 5 1 The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C and relative humidity of 15 90 48 5 2 The unit shall be capable of operating continuously in ambient temperature of 10 40deg C and relative humidity of 15 90 6 Power Supply Technical Bidders Specs Deviation if quoted by any bidder 6 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 7 Standards Safety and Training Sl Name Technical Bidders Specs Deviation if quoted by any bidder Td Manufacturer should be ISO certfied for quality standards 7 2 Comprehensive warranty for 3 years and 3 years AMC after warranty 7 3 Certified to be complying with FCC CE 0560 X or equivalent standards 8 Documentation Sl Name Technical Bidders Specs Deviation if quoted by any bidder 49 8 1 User Technical Maintenance manuals to be supplied in English 8 2 Certificate of calibration and inspection 8 3 List of important spare parts and accessories with their part number and costing
49. ber studs shall be provided on the paddle and both ends of 20mm SS square hollow pipe 155 REQUIREMENTS Lid of the Bin shall be foot operated and SS bottom rod of foot operated mechanism shall be minimum 8 mm It shall close to secure infected contents immediately upon releasing pressure Other requirements as per IS 3730 1988 Bin shall be preprinted as per requirements of Bio Medical Waste Management Rules 1998 amended till date Material used shall preferably match all requirements under relevant IS code Ready to use MARKING Each Bin shall be Marked Rajasthan Health Systems Development Project Govt of Rajasthan Properly labeled Bin to indicate Product Name Produced by Address Date of Manufacturing Size Batch Number Also refer IS 3730 1988 PACKING amp PACKAGING Each Bin shall be packed in poly film bag to reach destination securely Also refer IS 3730 1988 SPECIFICATION OF Plastic Bins Yellow Small Appendix S 4 NS 13 MATERIAL Plastic Bins HDPE LLDPE bins made from virgin polymer material thickness of bin shall be minimum 2 5 mm 0 2 mm with foot operated lid and handles for lifting also refer IS 3730 1988 for details Lid mechanism shall be of SS material only 156 CLASS amp SIZES SMALL 15 Lt HDPE bucket of Circular Top of about
50. buckets available in the market with DIMENSIONS suitably designed foot operated lid and proper handles for lifting the bin inner perforated bin shall also have collar holds to pull out replace the bin securely SS pipe wire rod used for cage handle and lid operation shall not be less than 4 mm dia SS Rod 2 No 20 x 20 mm SS Square hollow pipe shall be provided at the bottom for smooth and steady placement of the bin WORKMANSHIP amp FINISH As per IS 3730 1988 for HDPE LLDPE bin SS parts shall be smooth finished proper Rubber studs shall be provided on the paddle and both ends of 20 mm square hollow pipe REQUIREMENTS Lid of the Bin shall be foot operated and SS bottom rod of foot operated mechanism shall be minimum 8mm It shall close to secure infected contents immediately upon releasing pressure Other requirements as per IS 3730 1988 Bin shall be preprinted as per requirements of Bio Medical Waste Management Rules 1998 amended till date Material sheet used shall preferably match all requirements under relevant IS code Ready to use 160 Produced by an ISO 9001 2000 Certified Unit MARKING Outer Bin shall be Marked Rajasthan Health Systems Development Project Govt of Rajasthan Properly labeled Bin to indicate Product Name Produced by Address Date of Manufacturing Size Color White inner amp Blue outer bin Batch Numb
51. cleaners for dusty environment if applicable Fresh air ducting for fibrous conditions to prevent early choking of air cleaner if applicable Suitable orientation of Radiator cooled sets to avoid fiber Dust entry in DG GG room if applicable 60 Exhaust system Correct size of exhaust piping as per mode KVA Rating to ensure back pressure within specs Pipe size Silencer should preferably be located outside DG GG Room Insulation amp lagging of exhaust pipes silencer inside DG GG Room except elbow amp bellow Provide shortest exhaust pipe routing with minimum number of bends Thimble inside wall Exhaust pipe should be properly supported to avoid load on bellow Turbo Exhaust outlet orientation in wind flow direction Chimney Common ducting as per recommendations 70 Cooling system No immediate obstruction in front of radiator Location of cooling tower to ensure shortest possible pipe routing with minimum number of bends Size of raw water piping to ensure flow as per recommendations 56 Raw water as per recommendations HE raw water plumbing as per recommendations for multiple set installation Ensure use of strainer Cleaners Valves Instrumentation in raw water piping Cooling tower selection as per recommendations site conditions Recommended oil amp coolant water should be available during commissioning 80 Fuel System Diesel Genset Tank location as per recommendation should not obstruct free movement
52. cs Deviation quoted by if any bidder 8 1 User Technical Maintenance manuals to be supplied in English 8 2 Certificate of calibration and inspection 8 3 List of Equipments available for providing calibration and routine Preventive Maintenance Support as per manufacturer documentation in service technical manual 8 4 List of important spare parts and accessories with their part number and costing 69 8 5 Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job descriptin of the hospital technician and company service engineer should be clearly spelt out Equipment Specifications for I C U Beds UNSPSC Code 42191808 ECRI Code 10 351 1 Description of Function Technical Bidders Specs Deviation if quoted by any bidder 1 1 ICU Beds are required in the Intensive Care for comfort of the patient and to facilitate comfortable transfer to and fro emrgency OT Wards etc It is also required to carry out point of care procedures including radiological procedures at the bedside 2 Operational Requirements SI Name Technical Bidders Specs Deviation if quoted by any bidder 2 1 The system should be electrically operatable and adjustable for heights trendelenburg etc It should also be 70 2 2 having radiotransluscent top for carrying out X Ray at the bedside Demonstration of the system is a must Technical Specifications oral 352 3 3 3 4 Bx 3 6
53. ct situation arise the station or user key with the top priority will override the others This sequence of priorities shall be determined and programmed during the commissioning stage it shall be possible to change the sequence by on site as well as off site re programming as and when the need arises The system shall comply with country Public Address Evacuation Code of practice or IEC 60849 for the one way emergency voice communication system in all aspects All control and switching equipment shall be centralized and decentralized as specified and located in equipment racks in the FCC and equipment rooms No other equipment except the volume controls and cable patch panel shall be located outside the equipment rack All equipment supplied shall be from the same manufacturer Equipment supplied shall strictly be Standard Products from Public Address Product Manufacturer No tailor made product shall be acceptable The tendered shall submit catalogues of all equipment offered and upon delivery certificate of country of origin Certificate of Conformity and Certificate of Evacuation for the proposed PA Equipment shall be submitted Zoning for the passenger lifts shall be provided as provision and shall complete with the necessary wiring to be terminated in a termination box near the control panel in each lift motor room Group zoning for the lifts shall be allowed for evacuation announcement 2 SYSTEM REQUIREMENT For general office and public areas
54. d relative humidity of 15 90 6 Power Supply Technical Bidders Specs Deviation if quoted by any bidder 6 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 6 2 Resettable overcurrent breaker shall be fitted for protection 6 3 Suitable Servo controlled Stabilizer CVT 7 Standards Safety and Training Technical Bidders Specs Deviation if quoted by 141 Tid 7 3 7 4 7 5 7 6 Certified to be compliant with ANS IEC60601 2 12 01 Medical Electrical Equipment Part 2 12 Particular Requirements for the Safety of Lung Ventilators Critical Care Ventilators Should be FDA CE UL or BIS approved product Manufacturer should have ISO certification for quality standards Should meet IEC 529 Level 3 IP3X spraying water for enclosure protection water ingress Certified to be compliant with ISO 7767 for Oxygen monitoring Comprehensive warranty for 3 years and provision of AMC for next 3 years 8 Documentation SI 8 1 8 2 8 3 8 4 8 5 Name Certificate of calibration and inspection from factory List of Equipments available for providing calibration and routine maintenance support as per manufacturer documentation in service technical manual List of important spare parts and accessories with their part number and costing Service manual in English User manual in English 142 Technical Specs quoted by bidder Bidders Deviation if any 8 6 Log bo
55. d to be compliant with IEC 60601 2 38 Medical Electrical Equipments part 2 38 Particular requirements for safety of Electrically Operated Hospital Beds 7 7 Should have local service facility The service provider should have the necessary equipments recommended by the manufacturer to carry out preventive maintenance test as per guidelines provided in the service maintenance manual 7 8 Comprehensive warranty for 3 years and provision of CMC for next 3 years 8 Documentation SI Name Technical Bidders Specs Deviation if quoted by any bidder 8 1 Certificate of Calibration and inspection from the factory 8 2 List of Equipments available for providing calibration and routine maintenance support as per manufacturer documentation in service technical manual 8 3 List of important spare parts and accessories with their part number and costing 8 4 Log book with instruction for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out 8 5 Service manual in English 74 8 6 User manual in English 8 7 Must submit user list and performance report within last 3 years from major hospitals Specifications for Infantometer Readability to nearest mm For measurement of length for growth assessment in infants Technical Data Measuring range in cm 33 100 cm Measuring range in inch 13 39 Graduation Measuring Rod 1 mm
56. dthX 680mm Depth X 750mm Height with two storage units of 3 drawer unit and 1 unit of two drawers It should be made from square tubular infrastructure with a large top surface The product should have standard warranty with registered trademark OXYGEN CONCENTRATOR DOUBLE OUTLET 1 To deliver 8 Litres min 38 2 Dual Port each can deliver 4 litres min Advantage can be connected to 2 patients at a time 3 24 hour usable 4 Flow rate 1 10lpm 5 Outlet pressure 18 20 psig Alarms 1 Power failure 2 High amp Low pressure 3 Low purity test 4 temperature Advantage can be connected to 2 patients at a time 6 Advantage can be connected to 2 patients at a time 7 Three years Warranty and three years AMC 23 Double Surface Phototherapy LED type 39 Technical Specifications LED PHOTOTHERAPY UNIT Irradiance Minimum 40 pW cm nm 10 at 30 cm from the With adjustable Intensity High Medium amp Low Optical Sensor Radiometer Measurement band 0 uW cm nm to 200 uW cm nm Resolusion 0 1 uW cm nm Reading accuracy 2 uW cm nm Noise lt 52 dBA 40 Wavelength gt 450 460 nm peak 451 nm free of UV and IR radiation Electrical Specification Output Voltage 12 VDC Output power 50 W Input voltage 120 240 V 1 5 A Operating frequency 50 60 Hz Environments Requirement temperature range Operating 18 to 28 C 64 4 to 82 4 F Storage 20 to 60 C 4 to 140 F Relativ
57. e Technology Chestpiece Weight Diaphragm Diameter Diaphragm Material Diaphragm Type Eartip Type Extra Eartips Headset Material Length Model Net Weight approx Double sided 40 Gram 1 31 in 3 3 cm Epoxy Fiberglass Floating Diaphragm Soft Sealing Yes Wide Diameter Aerospace Alloy Anodized Aluminum 28in 71cm Pediatric 105 Gram 168 e Occupation Nurse Pediatrician e Patient Infant Pediatric e Small Diaphragm Diameter 1in 2 5cm e Special Adaptors No 69Foot Step for all labour tables amp ward beds e In 2 stepped preferrably e Made of Aluminium Metal with stable case non slippery e Dimensions approx 2 ft x 1 ft bxd with 6 inch step height to climb up to labour table 169
58. e humidity Operating 10 to 95 non condensing Storage 10 to 95 non condensing atmospheric Pressure Operating 700 hPa to 1060 hPa Storage 500 hPa to 1060 hPa Data transmission RS 232 serial port Standard UART protocol 41 Bits per second 9600 bps Data bits 8 Parity None Stop bits 1 Flow control None Lamp type Light emitting diode LED for 30 000 hours providing the same intensity level Height Adjustable from 1270 20 mm to 1730 20mm up to 90 on either side Time totalizer Digital compact 1 Time totalizer for the LED running time non resettable 2 Therapy timer for the treatment time resettable Examination lamp The LED PT is provided with 2 useful examination lamp that provides normal light when the baby needs to be attended to by doctors or nurses Alarms 1 Cooling fan failure 2 Temperature unit in light unit exceeds 50 C 3 Internal supply voltage is high 4 Internal supply voltage is low 5 Current consumption of LED s is not normal Messages are displayed on the time totalizer display Audible alarm is also produced u light unit 42 Cooling fan Centrifugal type to dissipate the heat created by LED s Power Requirements 120 240 V 50 60 Hz 1 5A Epoxy powder coated body for scratch and rust prevention and PU polyurethane coating for plastic parts 3 swivel casters including 2 with brakes Warranty 3years warranty and 3 years CMC ic Electrically Operated Pres
59. ed The system shall be capable of fulfilling the following requirements O Clear un distorted announcements to selected areas during public addressing O Clear un distorted paging to all zones either individually or collectively Selection of groups of zones shall be programmable from time to time and O Background music to selected areas when the other functions are not selected The loudspeakers shall be wired up in zones and with supervision localized volume controls as specified shall be provided so that the desired volume adjustments may be made Locations of localized volume controls are as indicated in the Schedules and or drawings The zones shall further be grouped according to function so that it shall be possible to make an announcement by depressing just one switch on the call station To allow flexibility in the system it shall be designed to be expandable with easy installation without changes in controller When the zones are selected for public addressing a chime shall first be heard followed by the announcement The system shall have a range of tones such that it shall be possible to programme different tones for call stations It shall be possible for the system to function with different call stations in operation provided there is no conflict in the zones being called by the call stations An emergency call station shall be provided for emergency The controller shall have a system of priorities such that should a confli
60. em with geared Stainless Steel handle for height adjustment from 75 mm to 1050 mm 3 MS rectangular tubular base is mounted on four castors of 50 mm diameter 4 Finish All components should be pretreated in separate eight tank process for better finish good adhesion and corrosion protection 5 Process includes i Hot Degreasing il De rusting iii Activation iv Phosphating amp No s of Water rinses as per IS 3618 1966 class C type and then pretreated materials is coated with epoxy powder with film thickness of 60 microns approx and then oven baked at 180 degree centigrade Warranty Standard Warranty 99 46 Oxygen cylinder with instrument set for Oxygen delivery Portable Oxygen cylinder portable with instrument set e Max Working Pressure at 150 C 150kgf cm2 e Test Pressure 250 kgf cm2 e Water capacity 2 5 to 3 0 Itrs e Gas Capacity Cu m 250 to 350 ltrs of gas e Min Wall Thickness t mm 3 2mm e Length T Approx mm 310mm e Tare weight approx kg 2 5 Kg e Built in online Pressure gauge regulator e Statutory certifications ISI Standards BMP Certification WHO amp Certified by Dept Explosives GOI 100 46 Portable X Ray TECHNICAL SPECIFICATIONS OF Portable X Ray Unit 60 mA a Operation Requirement 1 Compact light weight easily transferable portable X ray unit suitable for bedside X ray Box type 2 Effective breaking system with tube stand ful
61. er Also refer IS 3730 1988 PACKING amp PACKAGING Each Bin shall be packed in poly film bag to reach destination securely Also refer IS 3730 1988 Cooler fitted with RO Brand Type Storage Capacity Storage Capacity 150 ltrs approx Itrs Cooling Capacity 150 ltrs Itrs hr No of cold 2 water outlets 161 Storage Capacity Itrs Refrigerant Insulation In situ PUF insulation Compressor High Energy Efficient Compressor Condenser fan Thermostat Water connection through RO purifier Inlet Outlet Power connection Power supply Maximum Current amps 101 Itr and more CFC Free refrigerant ensures no damage to the environment ensures that water remains cool for a longer period in case of power failure and hence saves power Hermetic type with suction gas cooled motor equipped with overload protector Propeller type Quiet Automatically controls temperature 3m to 12m head Use pressure reducing valve if the water head is higher than 12m 12 7 mm BSP connection 25 4 and 12 7 mm BSP connection 5 amps 3 pin plug with proper earth connection or of suitable rating 230 Volts 10 50 Hz single phase 6 8 162 warranty 3year s Warranty with 3 years CMC Service Local Service network Warranty Both Water cooler amp RO to be under 3 years warrantee amp CMC contract form with charges from Year 4 6 TRANSPARENT COVER WITH WATER LEVEL INDICATO
62. er bed size 4 System Configuration Accessories spares and consumables Technical Bidders Specs Deviation if quoted by any bidder 4 1 I C U Bed Mainframe 01 4 2 Bed Ends detachable 01 pair 4 3 Articulated half length tuck away side rails 04 Nos 4 4 IV Rods 01 No 4 5 Mattress 12 cm Thick 01 No 5 Environmental factors Sl Name Technical Bidders Specs Deviation if 72 quoted by bidder 5 ei Shall meet IEC 60601 1 2 2001 Or Equivalent BIS General Requirements of Safety for Electromagnetic Compatibility 52 The unit shall be capable of being stored continuously in ambient temperature of 0 500 C and relative humidity of 15 90 5 3 The unit shall be capable of operating continuously in ambient temperature of 10 40deg C and relative humidity of 15 90 6 Power Supply SI Name Technical Bidders Specs Deviation if quoted by any bidder 6 1 Power input to be 220 240VAC 50Hz as appropriate fitted with Indian plug 6 2 Resettable overcurrent breaker shall be fitted for protection 7 Standards Safety and Training Technical Bidders Specs Deviation if quoted by any bidder 7 1 Electrical safety conforms to standards for electrical safety IEC 60601 IS 13450 7 2 Should be FDA or CE approved product 73 7 3 Manufacturer should have ISO certification for quality standards 7 4 Electric Shock Protection level Class B ES Electric current Protection Class 1 7 6 Certifie
63. er line mode 220 V 5 under battery mode 5 Protection Short Circuit Low Battery 6 AVR Built in Automatic Voltage Regulator AVR 7 Battery Type amp back up time Batteries shall be externally Sealed Maintenance Free SMF type The system must be capable of providing 30 minutes battery back up time and capacity and make of battery should be mentioned 8 Quality Certification The UPS OEM should be ISO 9001 amp ISO 14001 certified and preferably the certifying body should be accredited by Quality Council of India NABCB 9 Warranty 3 years On Site comprehensive warranty with 3 years CMC Printer MFP LaserJet 1 Multifunction Printer Print copy scan 2 Print speed black normal A4 Minimum 18 ppm 19ppm Ltr 3 Print quality black Minimum 600 x 600 dpi 1200 dpi 4 Print technology Laser 5 Standard memory Minimum 8 MB 6 Processor speed Minimum 400MHz 7 First page out black Before 10 sec 8 Media sizes supported Paper plain laser envelopes transparencies labels cardstock postcards 9 Duty Cycle Minimum 8000 pages per month 34 10 Connectivity standard Hi Speed USB 2 0 11 Compatible operating systems Microsoft Windows Operating System including Windows 8 Windows 7 Windows Vista Windows XP etc 12 Power consumption active 220 240 VAC 13 Smart Install technology Plug amp Play
64. es are used for sending and receiving fax messages faster 2 Operational Requirements Sl Name Technical Bidders Specs Deviation if quoted by any bidder 261 Should have data fax modem that provides users with the highest possible data communication rates reliable error free transmissions and widespread interoperability with other users 3 Technical Specifications SI Name Technical Bidders Specs Deviation if quoted by any bidder 3 1 e Digital Fax Machine Plain Paper Specifications Machine type Desk top digital plain paper fax machine Line type PSTN EPABX Printing Technology laser Compatibility ITU Group3 Document size A4 210x297mm Effective scanning amp recording width A4 Min 200mrn for A4 size Scanner CIS or CCD Type Printing Paper Size A4 210 x 297rnrn ONA UO RWNH 47 9 Capacity of Tray Minimum 50 sheets 10 Transmission Speed ITU Test Chart of A4 Size Details to be furnished by tenderer 11 Scanning Resolution 200 x 100 DPI Standard Mode 200 x 200 DPI Fine Mode 12 Modern Speed 14 4 Kbps Fine Mode 13 Printing Resolution 600 x 300 dpi min 14 Memory 0 5 MB Min 15 Essential features i Automatic Document Feeder 10sheets min ii Activity Report Capacity to be specified by tenderer iii Successful Transmission Completion Report iv Tx Terminal Identification v Remote Terminal Identification vi Error Code Identific
65. es manufacturers to meet the conditions required for use of CE mark A certificate of Conformity to the Test Parameters and a Certificate of Origin indicating the country of origin and date of manufacture shall be available to the Buyer for all the instruments and equipment General Specifications for Surgical Instruments The packs required by FHD are modifications of packs described in Obstetrics and Contraceptive Surgery at the District Hospital A Practical Guide Maternal and Safe Motherhood Programme Division of Family Health WHO MCH MSM 92 8 and Mother Baby Package Implementing Safe Motherhood in Developing Countries Maternal and Safe Motherhood Programme Division of Family Health WHO FHE MSM 94 11 a Each pack must be packaged in a hospital grade cotton wrapper autoclavable as a complete pack and the wrapped packs must be packaged in a labelled clear plastic box The remaining packs shall be in the cotton wrapper only Bulk loose instrument supply is NOT acceptable Each of the individual content of the packs must be in a clear plastic wrapper labelled on the outside for easy identification of the individual instruments b Instruments must be made from surgical quality stainless steel and must be matt surface finish Quality should comply with EN 46002 and ISO 9002 All surgical instruments must be autoclavable at 134 C and a third party European CE certificate should be produced in this regard for its reusability c
66. etoscope 0 0 0 20 o 3000 3020 500 1510000 47 21 Filing Cabinets for records 4 drawer 0 0 0 12 0 0 12 8000 96000 Ag 22 Flux Meter 0 1 0 0 0 0 1 9375 9375 48 23 Formalin Vaporizer 1 1 0 6 0 0 8 3000 24000 50 24 Generator 65 KVA 1 1 0 1 0 0 3 284750 854250 50 25 Geyser 2 2 0 0 0 0 4 7000 28000 57 2g Glucometer With strip 10 20 0 2 0 0 32 4500 144000 58 27 Hotair oven 0 0 0 2 0 0 2 4500 9000 59 Hydraulic OT Table Minor 0 0 0 2 0 0 2 40000 80000 63 29 ICU Bed 0 0 o 20 o0 0 20 22000 440000 6g 30 Infant meter 0 2 0 0 0 0 2 1000 2000 72 31 Instrument Trolley SS 0 0 0 50 0 0 50 2200 110000 73 32 Intercom 15 lines 0 0 0 1 0 0 1 50000 50000 74 33 Intercom 40 lines 0 0 0 1 0 0 1 150000 150000 74 a 3 Inverter with two tubular batteries 3000 watts 0 0 0 5 5 0 4 25000 100000 equipment running capacity 75 35 Ip Camera 5 0 0 0 10 8000 80000 77 36 KMC Chair o o 20 0 0 20 15000 300000 78 37 LCD monitor 18 with LCD player 1 1 2 12 0 0 16 30000 430000 79 38 Linen Trolley 0 0 12 0 0 0 12 10000 120000 79 40 Mattresses of Foam 0 0 o 300 1133 o 1433 2000 2866000 91 41 N20 Cylinder fo Boyles 0 0 0 16 0 0 16 4400 70400 91 42 Nebulizer Machine 0 0 6 0 0 0 6 1200 7200 92 43 O2 cylinder for Boyles 1 5 cu m B type 0 0 0 16 0 0 16 4400 70400 95 i Over Bed Side Table for Patient 0 0 0 20 0 0 20 1200 24000 96 45 Oxygen cylinder wit
67. f 5 mm Insulated stainless steel door with locking and rear zinc plated steel Interior w x h x d 40mm x 45mm x 30 mm 55 litres app all dimensions will have a tolerance of 5 mm easy to clean interior made of stainless steel with supports on the three sides for three adjustable perforated stainless steel shelves Forced air circulation by quiet air turbine Fan to ensure uniform temperature Fitted with load indicator and safety thermostat take over indicator lamp LCD LED Indicator Temperature Variation 1 deg C Temperature Range ambient to 250 deg C Output available for data acquisition 4 System Configuration Accessories spares and consumables SI 4 1 Name Technical Bidders Specs Deviation if quoted by any bidder System as specified 5 Environmental factors 63 Technical Bidders Specs Deviation if quoted by any bidder 5 1 The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C and relative humidity of 15 90 5 2 The unit shall be capable of operating continuously in ambient temperature of 10 40deg C and relative humidity of 15 90 6 Power Supply Sl Name Technical Bidders Specs Deviation if quoted by any bidder 6 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 6 2 Voltage corrector stabilizer of appropriate ratings meeting ISI Specifications Input 160 260 V and output 220 240 V and 50 Hz 7 Standards Safety and Tr
68. from Year 3 5 59 All above to be ISI standard or equivalent Item Description Sr No Item Description Geyser for hot water flow Body ABS Capacity 25 litres Overheating thermostat protection Yes Powerconsumption 2000 Watts ISI marked European CE or USFDA approved Warranty 2years with 3 years CMC Energy efficient preferably with 5 star rating WOON DU RWN PB Minimum Dimensions 60cmx35cmx 37cm pa jo Documents warranty card with service manual and service centre details Warranty 3 years and 3 years CMC ia Glucometer With strips Blood Glucose Meter Sr No Description of Technical Specification Description of Function 1 1 Should be a hand held meter 1 2 Should require no routine maintenance 1 3 Should have reading range linearity from 20 to 600 mg dl 1 4 Should have a maximum reading time of less than 10 seconds 1 5 Should use electrochemical technology 1 6 Should use a minimum blood sample less than 1 5u1 60 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 2 2 1 22 2 3 2 4 23 3 1 Oo N 3 3 Should have a LCD display Should have measuring unit in mg dl Should have wide operating temperature Should have life time replacement offer Should have easy code entry technique Battery should be replaceable without using any tools Should have facility to ensure accuracy of measurements Should be supplied with three types of control solutions of each at least 20 ml Should be Eu
69. g and analysis capability with stereotactic biopsy facility S N Operational requirements 2 1 Full Digital Mammography System consisting of exposure stand with attached swivel system separate console with radiation shield automatic exposure control and mammography X Ray Tube 2 2 An integrated direct to digital Flat Detector based on amaorphous silicon technology 2 3 A separate workstation for image positioning and patient demographic data is required 2 4 The workstation should be able to send receive and printaccording to DICOM standards 2 5 The workstation should also be able to obtain DICOM modality work list from connected information system and send information about performed procedure to the connected information system 83 2 6 Read and Write in CD DVD for data Storage and review S N Technical Specifications 3 1 Mammography System 01 The system should consist of a tube head and detector assembly that has iso centric rotation for every positioning The iso centric movements should be motorized The patient Compression device should have automatic multispeed variable compression system which senses the breast density and adjust the compression force The maximum compression thickness should be 18 cm or more The patient table should have motorised grid movement Magnification devices of ratio 1 5 and 1 8
70. ge 166 Manometer range 10 to 80 cm H20 mbar Manometer accuracy 2 0 of full scale deflection Max Pressue Relief 8 L min 5 to 70 cm H20 mbar Factory set 40 cm H20 mbar Peak Inspiratory pressure PIP 5 L min 2 to 70 cm H20 m Bar 8 L min 3 to 72 cm H20 m Bar 10L min 4 to 73 cm H20 m Bar 15 L min 3 to 75 cm H20 m Bar Positive end expiratory pressure PEEP 5 L min 1 to 5 cm H20 mbar 8 L min 1 to 9 cm H20 mbar 10 L min 1 to 15 cm H20 mbar 15 L min 1 to 25 cm H20 mbar Storage temperature range 10 to 50 C 14 to 122 F upto 95 humidity Operating temperature range 18 to 50 C 4 to 122 F upto 95 of humidity Included with Gas supply line gas inlet adapter test lung spare max pressure relief cap animated user guide CD operating instructions and product technical manual e Warranty Terms 3 years warrantee amp CMC contract form with charges from Year 4 6 67 LED Light Source Technical Data of led Cold Light Source Lamp led Color Temperature 6000 K 167 Device type I B Lamp Power Equivalent to 300Watt xenon Input Power 400 W Case Temperature lt 55 C Working Noise lt 55DB Operating Life 50 000 00 hours Outside electrical source 220V 10 50Hz Working Environmental Humidity 5 32 C Relative Humidity lt 70 Dims standard Net Weight standard e Warranty Terms Standard warranty 68 Neonatal Stethoscope Machined Stainless Steel Chestpiec
71. h instrument set for Oxygen 0 0 0 100 483 1500 2083 8000 16664000 delivery Portable 97 46 Portable X Ray Machine 1 1 0 2 120000 240000 99 47 Printer For Computer 1 1 0 2 10000 20000 100 ae Public Address System 0 0 0 1 0 0 1 30000 30000 103 49 Pulse Oxymeter multi channel monitor 0 0 0 15 74 34 123 20000 2460000 108 50 Pulse Oxymeter With Neonatal Probe 20 20 0 0 0 0 40 17200 688000 113 51 Racks Steel 0 o 10 60 0 0 70 3000 210000 113 52 Security wise CCTV Camera 0 0 0 16 0 0 16 10000 160000 113 53 Semi auto analyser 0 0 0 1 0 0 1 84000 84000 118 54 Servo Controlled Online Voltage Stabilizer 150 KVA 6 4 0 0 0 0 10 160000 1600000 122 55 Split AC Two ton with remote with installation 0 0 10 67 206 0 283 41000 11603000 123 56 Transcutaneous Bilirubinometer 0 1 0 0 0 0 1 74145 74145 126 57 Ventilator ICU 0 0 0 2 0 0 2 950000 1900000 128 58 Ventilator Pediatric 2 1 0 0 0 0 3 1013250 3039750 135 59 Wall mounted B P Apparatus 0 0 0 20 0 0 20 2200 44000 141 60 Washing Machine 1 1 0 0 0 0 2 9000 18000 142 61 Washing Machine Dryer 1 1 0 0 0 0 2 15000 30000 144 Waste Disposal Bin drums Color coded bins 62 set of both big and small to be quoted in assorted 0 0 12 750 4500 5262 350 1841700 colours along with sharps bin 145 63 Drinking Water cooler with RO 5 la k 9 i is el SAUN 159 64 Water filter Reverse Osmosis 3 3 1 0 0 7 17000 119000 161 i
72. his equates to 2000 mg m8 Dimensions Without Fittings Depth 4 92 in 12 5cm Width 2 25 in 5 7cm Height 4 10 in 10 4cm Weight 2 9 lbs 1 3kg 3 4 lbs 1 5kg Operating Temperature 59F to 104F 15T to 400 165 e FiO2 Accuracy 3 of full scale Bypass Alarm Activation 18 22 psi 1 2 1 5 bar Primary Outlet Flow Range 3 30 L min 3 Auxiliary Outlet Flow Range 0 30 L min Bleed Flow at 50 psi 3 4 bar 3 L min or less Maximum Combined Flow all outlets 230 L min e No of Primary Outlet Ports 1 3 1 DISS 5 DISS Order separately e No of Auxiliary Outlet Ports 1 1 1 DISS 1 DISS Order separately e Inlet Pressure 2 1 5 2 bar 30 75 psi e Inlet Fitting DISS DISS NIST e Warranty Terms 3 years warrantee amp CMC contract form with charges from Year 4 6 _66_T piece Resuscitator Easy to use The experience training concentration and fatigue level of the operator do not affect the pressures delivered Flexibility in operation The neopuff can accept and deliver oxygen concentrations from 21 to 100 coming from a flowmeter or a blender The T piece circuit can connect to infant resuscitation masks or endotracheal tubes Accurate pressure delivery The fast acting manometer provides constant reassurance of mask seal and delivered PIP and PEEP Alternate temporary respiratory support Consistent PEEP can be delivered to assist with breathing during transport or ventilator circuit chan
73. ies 8 Warranty 9 Maintenance Range 70 99 Range 50 99 20 250 bpm 20 200 bpm System alarmsProbe failure Poor signal Power failure 12 hours 20 sec 2 12 hours 220 240 V AC 50 60 Hz Rechargeable internal battery Battery back up at least 2 hours 10 Re usable finger probes 10 Re usable flexible multi site probes 3 years from date of installation 3 years CMC after warranty period 114 Slotted Racks Overall size minimum height 6feet width 3feet Prime quality cold rolled close annealed steel is treated with unique seven stop anti corrosion process for extra durability the multi bend seamless construction ensures rigidity and prevents pests from entering Automatic airless electrostatic painting using alkyd amino pain provides a smooth scratch resistant surface 52 Security wise CCTV Camera Technical Specifications of Camera Image Sensor 1 3 HDIS Signal System PAL Lens 4 mm Fixed Board Horizontal Resolution 720 TVL Effective Pixel 768 H x 494 V S N Ratio More than 50dB IR LED 24 IR Distance 20 Meters 115 Video Output Signal 1 0Vp p Composite Signal 75 Ohms Scanning Frequency 15 625 Khz H amp 50Hz Signal Process Digital Scanning System 2 1 Interlaced Minimum Illumination O Lux F1 2 IR ON Auto Gain Control Yes Electronic Shutter 1 50 1 100 000 White Balance Auto Day amp Night Auto Operating Temperature 10 C to 50 C Power Source DC 12V A DVR camera is a security system
74. ils 34 Invertor with two tubular batteries 3000 watts equipment running capacity Model Exide or Equivalent make as per load for 8 hours around 13 batteries of 150 AH 1 Watts Volts x Amps 2 Battery capacity is expressed by how many Amps for how many hours a battery will last Amp Hour A H capacity 3 For a 12 Volt inverter system each 100 Watts of the inverter load requires approximately 10 DC Amps from the battery 4 For a 24 Volt inverter system each 200 Watts of the inverter load requires approximately 10 DC Amps from the battery The first step is to estimate the total Watts or Amps of load and how long the load needs to operate This can be determined by looking at the input electrical nameplate for each appliance or piece of equipment and adding up the total requirement Some loads are not constant so estimations must be made For example a full sized refrigerator 750 Watt compressor running 1 3 77 of the time would be estimated at 250 Watts per hour After the load and running time is established the battery bank size can be calculated The first calculation is to divide the load in Watts by 10 for a 12 Volt system or by 20 for a 24 Volt system resulting in the number of Amps required from the battery Bank A full sized refrigerator draws about 2 Amps at 120 Volts AC By multiplying 2 Amps x 120 Volts the refrigerator uses 240 Watts The batteries will need to deliver 20 Amps to run the refrigerator 240 Watts 12 V
75. ive humidity 30 to 95 without condensation DURING STORAGE AND TRANSPORT 129 Temperature 10 to 50 14 F to 122 F Air pressure 700 hPa to 1060 hPa Altitude range 400 m to 3 000 m Relative humidity 30 to 95 without condensation Warranty 3 years with 3 years CMC 57 Ventilator Equipment Specifications for Ventilator I C U UNSPSC Code 42272205 ECRI Code 17 429 1 Description of Function Technical Specs quoted by bidder 1 1 ICU ventilators provide artificial respiratory support to the critical patients in the Intensive Care Units 2 Operational Requirements Technical Specs quoted by Bidders Deviation if any Bidders Deviation if 130 Microprocessor Controlled ventilator with integrated facility for Ventilation monitoring suitable for New born to adult ventilation 2 2 Demostration of the equipment when ever required 3 Technical Specifications Technical Bidders Specs Deviation if quoted by any bidder 3 1 Imported hinged arm holder for holding the circuit 3 2 Colored TFT screen 10 Inch or more 3 3 Facility to measure and display a line deleted b min 2 waves Pressure and Time Volume and Time and Flow and Time c min 2 loops P V F V P F with facility of saving of min 2 Loops for reference d Graphic display to have automatic scaling facility for waves e Status indicator for Ventilator mode Battery life patient data alarm settings clock etc 3
76. l for places where the problem of low Voltage high voltage and unexpected and continuous voltage fluctuationsexists TECHNICAL SPECIFICATIONS Rating 1KVA to 1000KVA Input Voltage 160 260 140 270 90 279V 1Phase 340 470 300 470 240 470V 3 phase Input frequency 50 Hz 10 Output Voltage 230V 1 Phase Pre Settable range 215 235 410V 3 Phase Pre settable range 380 415 Output Regulation 1 or 0 5 Wave form distortion Nil Motor Type Nonflammable burn proof high torque ACsynchronize motor Warranty 3 years with 3 years CMC 124 55 Split AC 5 star rating Two ton with installation Equipment Specifications for Air Conditioner 2 Tons 1 Description of Function Technical Bidders Specs Deviation if quoted by any bidder 1 1 Required for cooling dehumidifying air circulation ventilation and filtering in the sizes of nominal cooling capacities 2 Operational Requirements Technical Bidders Specs Deviation if quoted by any bidder 2 1 Split Type Room Air Conditioner is required 2 2 Capacity of 2 Tons is required with installation 3 Technical Specifications Technical Bidders Specs Deviation if quoted by any bidder 125 3 1 1 Approx Over all Dimension of a The unit LxHxD cms Company Standard Dimentions for 2 ton AC Split type of 5 star rating 2 Details of Compressor a Name of Compressor KILOSKAR TECUMSEH or equivalent b Maximum full load current
77. leasing pressure Other requirements as per IS 3730 1988 Bin shall be preprinted as per requirements of Bio Medical Waste Management Rules 1998 amended till date Material used shall preferably match all requirements under relevant IS code Ready to use MARKING Each Bin shall be Marked Rajasthan Health Systems Development Project Govt of Rajasthan Properly labeled Bin to indicate Product Name Produced by Address Date of Manufacturing Size Batch Number Also refer IS 3730 1988 PACKING amp PACKAGING Each Bin shall be packed in poly film bag to reach destination securely Also refer IS 3730 1988 SPECIFICATION OF Plastic Sharps Bins for Disinfection 159 Appendix S 4 NS 19 MATERIAL Plastic HDPE LLDPE bins made from virgin polymer material thickness of Bins bin shall be minimum 2 5 mm 0 2 mm also refer IS 3730 1988 for details with foot operated lid and handles for lifting amp lid mechanism shall be of SS material only Outer Bin of min 25 It volume with matching inner bin of about 20 It CLASS amp SIZES volume having perforations in the side wall and bottom holes of about 2 3 mm size both having matching top diameters Outer bin shall be of blue colour and inner bin shall be of white colour Sizes as per standard HDPE LLDPE
78. ler shall be the Bosch Plena Voice Alarm Controller 1990 00 The router shall be the Bosch Plena Voice Alarm Router 1992 00 The call station shall be the Bosch Plena Voice Alarm Call Station 1956 00 The cal station shall be the Bosch Plena Voice Alarm Call Station Keypad 1957 00 1 GENERAL REQUIREMENT The design supply delivery installation testing commissioning and maintenance of the Public Address System shall include but not limited to the following O Recessed mount ceiling surface mount column and or horn speakers sound projectors box and bi directional box speakers c w line matching transformers and volume controls where applicable O Termination of all cables to speakers power amplifiers etc 106 Equipment rack complete with forced air ventilation fan s mounting brackets blank panels terminal boards etc O Main equipment and all associated auxiliary equipment O Distribution cabling including fire rated cables where applicable cable ladders racks and Cable supporting systems cable trunking and concealed metal conduits O All other works and materials necessary for the efficient operation of the whole audio system Complete with power supply requirements and surge arrestors and filters The primary objective of the system is to provide clear announcements during public addressing and one way voice communication during an emergency the secondary function shall be to provide background music where requir
79. llation properly covering on call technical interventions spare parts and travel After warranty of three years is over the bidder must cover for three years under CMC 52 Waste Disposal Bin drums Waste Disposal Bin drums Color coded bins set of both big and small to be quoted in assorted colours SPECIFICATION OF Plastic Bins Red Big Appendix S 4 NS 11 MATERIAL Plastic HDPE LLDPE bins made from virgin polymer material thickness of Bins bin shall be minimum 2 5 mm 0 2 mm with foot operated lid and handles for lifting also refer IS 3730 1988 for details Lid mechanism shall be of SS material only CLASS amp SIZES BIG 25 Lt 147 HDPE bucket of Circular Top of about 340mm 10mm without collar amp circular Bottom of about 280mm 10mm Height 360mm 10mm with suitably designed foot operated lid and proper handles for lifting the bin SS pipe wire rod used for cage handle and for operation of lid shall not be less than 4mm dia SS rod SS Square hollow pipe 2 Nos of 20x20 mm shall be provided at the bottom for steady placement of the bin DIMENSIONS SS pipe wire rod shall be not less than 4 mm dia WORKMANSHIP amp FINISH As per IS 3730 1988 for HDPE LLDPE bin SS parts shall be smooth finished proper rubber studs shall be provided on the paddle and both ends of 20mm SS square hollow pipe Lid of the Bin shall be foot operated and SS b
80. ly counter balanced with rotation in all direction 3 Exposure with remote control should be available 4 Cassette storage facility for all size cassettes along with cassettes screen 15 x 12 4 Nos 12 x 12 4 nos 12 x 10 4 nos 10 x 8 4 nos 800 speed cassettes 5 Lead blocker 15 x 6 2 nos 6 Lightweight lead apron 2 nos 7 Lead letters amp numbers 2 sets 4 nos b Technical Specification 1 mA range 60 mA light weight kV range 40 kV to 90 kV 2 Should have digital display of mAs and kVs 3 3 Microprocessor controlled high frequency output 15 kW or above c X ray Tube 1 Stationary Anode 101 2 Light beam collimator of multi leaft type of auto cutoff switch 3 Exposure release switch should be detectable with a cord of sufficient length minimum 30 meters as per IRCP recommendation d Standard Safety 1 Should comply with AERB BIS IRCP guidelines for radiation leakage and X ray equipments e Documentation 1 Comprehensive warranty for 3 years on complete system including X ray tube amp accessories all vaccumated items 2 CMC for 7 years for complete system including X ray tube and all vaccummated items amp accessories Equipment Specifications for Mono Laser Printer 20 PPM Language Printer 1 Description of Function Technical Bidders Specs Deviation if quoted by any bidder 2 O
81. ly designed foot operated lid and proper handles for lifting the bin SS pipe wire rod used for cage handle and for operation of lid shall not be less than 4mm dia SS rod SS Square hollow pipe 2 Nos of 20x20 mm shall be provided at the bottom for steady placement of the bin DIMENSIONS SS pipe wire rod shall be not less than 4 mm dia WORKMANSHIP amp FINISH As per IS 3730 1988 for HDPE LLDPE bin SS parts shall be smooth finished and powder coated proper rubber studs shall be provided on the paddle and both ends of 20mm SS square hollow pipe REQUIREMENTS Lid of the Bin shall be foot operated and SS bottom rod of foot operated mechanism shall be minimum 8 mm It shall close to secure infected contents immediately upon releasing pressure Other requirements as per IS 3730 1988 149 Bin shall be preprinted as per requirements of Bio Medical Waste Management Rules 1998 amended till date Material used shall preferably match all requirements under relevant IS code Ready to use Produced by an ISO 9001 2000 Certified Unit Each Bin shall be Marked Rajasthan Health Systems Development MARKING Project Govt of Rajasthan Properly labeled Bin to indicate Product Name Produced by Address Date of Manufacturing Size Batch Number Also refer IS 3730 1988 Each Bin shall be packed in poly film bag to reach destination PACKING amp PACKAGING securely Also refer IS 3730 1988
82. lysate and whole blood 120 2 Operational Requirements 2 1 Technical Specs quoted by bidder Should be open system and Supports bi chromatic tests for end point fixed time kinetics methods 3 Technical Specifications 3 1 3 2 3 3 3 4 3 5 Technical Specs quoted by bidder Should be microprocessor controlled general purpose bi chromatic photometer Self monitoring temperature system with at least 6 filter ranging from 340 to 630nm Light source Tungsten halogen or higher grade with one additional bulb controlled absorbance reading Should have end point kinetic and two point kinetic measurement modes Should have flow cell measuring device Bidders Deviation if any Bidders Deviation if any 3 6 Should have a measurement range from 0 001 to 2 300Abs 3 7 Should have facility for reading results on LCD display 3 8 Should have quality control two control test QC survey 4 System Configuration Accessories spares and consumables Technical Specs quoted by bidder 4 1 Integrated Printer 5 Environmental factors Technical Specs quoted by bidder 5 1 Shall meet IEC 60601 1 2 2001 Or Equivalent BIS General Requirements of Safety for Electromagnetic Compatibility 5 2 The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C and 122 Bidders Deviation if any Bidders Deviation if any relative humidity
83. marked Indian or European CE or USFDA approved Warranty 3 years and 3 years CMC 24 Generator Diesel Power Generator 65 KVA Eco friendly Power Generation Sets are first in the world to meet the Central Pollution Control Board CPCB norms issued by Ministry of Environment amp Forests Government of India 52 the type approval from ARAI for emission compliances the ISO 9001 certifications for Quality Management Systems ISO 14001 for Environmental Management Systems warranty of 24 months from the date of the DG set supply or 5000 normal operating hours whichever is earlier Ranges 10KVA to 600KVA 20 28 32 50 4 60 80 KVA upto 40 air cooled above that radiator cooled D G Set Voltage 415 Volt 3 PH AC 1500 RPM 0 8 PH 50 C S ENGINE BS 5514 1S 10000 amp DN 6271 ISO 3046 ALTERNATOR IS 4722 BS 4999 5000 SOUND LEVEL 75 dB A at 1 meter distance Recommended In view of the frequent interruptions in power supply as well as prolonged power outages provision of DG set is deemed compulsory One 10 KVA DG set for each District Centres with Instrument Meter panel and shed will be provided Required range 65 KVA KIRLOSKAR or equivalent AIR COOLED DIESEL GJENERATOR SET WITH CPCB APPROVED SOUND PROOF ENCLOUSER COMPRISING OF KIRLOSKER ENGINE EA 16 16 BHP 1500 RPM AIR COOLED COUPLED WITH KIRLOSKER 10 KVA SINGLE PHASE ALTERNATOR ON COMMON BASE FRAME ALONGWITH STANDARD Required features Silent DG Sets with Auto
84. n 1 PMM V V of nitric oxide less than 1 PPM V V nitrogen dioxide less than 25 PPM V V of NH3 less than 1 PPM V V of halogens and less 93 than 200 PPM V V of water e Should be free of reducing substance oxidizing substances and hydrogen sulphide e Cylinder capacity i A type 0 75 cubic meter ii Bulk cylinder 7 0 cubic meter The Manufacturer dealer firm should have WHO GMP DHQH ISI BIS registration certificate with a valid drugs licence and explosive License Should cover Standard Warranty terms Note The instrument to be supplied first time with set for oxygen delivery Log book must be submitted with the Cylinder for supply records and a service book for maintenance records 42 Nebulizer Machine Equipment Specifications for NEBULISER 1 Description of Function Technical Specs quoted by bidder Bidders Deviation if any 1 1 Nebulizer is a device used to administer medication to people in forms of a liquid mist to the airways It is commonly used in treating cystic fibrosis asthma and other respiratory diseases 2 Operational Requirements Technical Specs Bidders Deviation if quoted by 94 Heavy duty compact Nebuliser is required 3 Technical Specifications Technical Bidders Specs Deviation if quoted by any bidder 3 1 Technical Specifications Nebuliser 1 Compact light weight low noise 2 Durable long life compressor Suitable for heavy duty institutional hospital use
85. n all the monitors 3 6 Multichannel upto 12 leads ST segment anlysis B37 Facility to monitor and display ECG Respiration NIBP SpO2 CO2 with capnography Temp Cardiac output optional NMT Optional BIS Entropy optional EEG optional amp IBP 3 8 Automatic arrhythmia detection amp alarm for standard and lethal arrhythmia 3 9 Line is deleted 3 10 NMT Module monitor For measurement and display of TOF count TOF ST DBS Tetanic and Trend for continuous usage Automatic measurement facility in selected time interval Automatic selection of supramaximal current Include standard accessories 3 11 EEG Module with all accessories 3 12 Central station for bedside monitors with independently controlled 17 multi colour TFT Monitor 26 3 13 3 14 3 15 3 16 3 17 3 18 3 19 3 20 3 21 3 22 complete with Ethernet LAN cabling alarm management 72 hours trending bed to bed viewing of waveforms and remote alarm management like silencing of alarms etc OPTIONAL Should provide hemodynamic oxygenation Ventilation calculation package Should have drug calculation package Trend of at least 48 hours 200 nos event recall snapshot facility both manually and automatically triggered by alarm Automatic Zoom In Facility in the monitor dispaly The monitors should have monitor to monitor overview facility and data transfer over the network Web browsing facility to review each networked m
86. nal Anti 32 Glare Screen Protector with 5 ms or better response time TCO 05 certified and with inbuilt speaker 5 Ethernet Integrated 10 100 1000 MbpPS i e Network Integrated Gigabit Ethernet controller 6 Mouse 2 Button Optical Scroll Mouse USB Same OEM make amp brand 7 Optical Drive Optical Drive Dual layer DVD writer 8 Hard Disk 500 GB or higher 7200 RPM SATA II 9 Graphics On Board Integrated Graphics 10 Key Board Standard 104 Keys Same OEM Make and brand as the system 11 Slots 2 nos PCI 1 Nos PCI Express x 16 amp 1 Nos PCI Min 12 Audio Integrated sound controller with Head Phone amp Microphone 13 1 0 Ports 1x fast serial port 4x USB 2 0 ports 2 ports on front 1xKeyboard port 1xMouse port 14 Power Supply 200 280 Watt min 90 or higher efficient power Supply with Energy Star 5 0 or BEE star compliant 15 Operating System Genuine Windows 7 or higher with latest Service Pack Preloaded license OEM Media in form DVD CD containing OS and Driver Recovery Media must be provided 16 Warranty 3 years On Site OEM Comprehensive Warranty with 3 years CMC 17 Antivirus Software Pre Loaded with Antivirus activation code and 1 year update license 1 Type Line interactive 2 Capacity Minimum 800 VA power factor 33 3 Input Voltage Range 140 280 V AC 4 Output Voltage 220 V 10 und
87. nging output The power amplifiers are provided with compact 19 2U amp 3U high housing for tabletop use and rack mounting while the maximum amplifier wattages varies from 120w to maximums 960w The amplifiers are protected against overload and short circuits A temperature controlled fan ensures high reliability at high output power and low acoustic noise at lower power output Additionally all booster amplifiers have an overheat protection circuit that switches off the power stage if the internal temperature reaches a critical limit due to poor ventilation or overload Balanced input and a loop through connector shall be available for easy connection of multiple booster amplifiers to increase the available output power The power amplifier shall obtain two balanced inputs with priority control each with a loop through facility This allows for easy and automatic switching between e g a local music source and a priority announcement from a remote system An additional 100V line input is provided to connect the booster amplifiers to a 100V loudspeaker line for additional output power e g on remote locations Sensitivity or level control is located on the rear of the unit to avoid accidental setting change A VU meter with LED bar shows the output level The amplifiers not only provide 70V and 100V outputs for constant voltage loudspeaker systems a low impedance output for 8 Ohm loudspeaker loads is available for different usage The booster amplifie
88. nnel RCA 1 channel RCA RJ45 10M 100M Base TX 1 x RS485 2 x USB2 0 1x SATA Supports USB USB DVDRW Network TCP IP DNS PPOE DHCP DDNS UDP FTP E mail Alarm Server 118 IP Filter Remote Operations Monitor PTZ Control Playback Setting Video Download Logs Power Supply DC12 10 Power Consumption lt 15W HDD not included Working Temperature 10 C 55 C Working Humidity 10 90 RH Audio functions System can record Audio surround synchronized with video of particular area 3 layer remote monitoring System can be monitored on different levels of monitoring as follows e Cluster of District officer level e Division level e State level CMS based Centralized remote monitoring e Video Wall Solution Unlimited Live Views e 64 channel Live Video Monitoring with Dual Monitors e 16 channel Synchronous Playback 119 e PTZ ePTZ PiP Digital Zoom Function Control e Alarm Management e Overall Device Management Feature e Multi channel Audio Broadcast e Post Video Enhancement and Defog e Instant Replay amp Playback on Live Client e Auto Stream Size for Reducing Display Loading e Web Access via Internet Explorer e Windows Active Directory Integration Equipment Specifications for Semi Automatic Bio Chemistry Analyzer 1 Description of Function Technical Bidders Specs Deviation if quoted by any bidder 1 1 For analysis of serum plasma urine cerebrospinal fluid CSF hemo
89. nspection should be submitted iii List of important spare parts and accessories with their part number and costing iv Log book with instruction for daily weekly monthly and quarterly maintenance checklist v The job description of the hospital engineer should be clearly spelt out 17 Emergency resuscitation kit adult amp Pediatric EMERGENCY RESUSCITATION KIT ADULT amp BABY In a carrying case consisting of Resuscitator adult 1 pcs Resuscitator chilled 1 pcs Suction Foot Type Small 1 pcs L Scope 4 Blade S S 1Set L Scope 2 Blade S S 1Set Oxygen Hood Round Jointless 1Set E T Tube for adult 3 Pcs E T Tube for Ped 3 Pcs Airways plastic Set of 3 pcs 1Set Styllete Set of 3 pcs 1 Set 45 Face mask Round shape 1 Set Face mask rubber 1 Set Mucus Extractor 2 Pcs M Forceps Set of 3 pcs 1 Set M Brush Set of 3 pcs 1 Set Mouth Bite Set of 3 pcs 1 set The Items in the kit should be European CE or USFDA approved 18 Enema Set Designed with a spill proof valve on the 1500 cc enema bag and easy use funnel top 54 soft vinyl tube has a pre lubricated smooth non traumatic tip with rounded eyes for safety and easy insertion Set also contains a moisture proof castile soap packet and a plastic shut off clamp Equipment Specifications for Digital Fax Machine UNSPSC Code ECRI Code 46 1 Description of Function Technical Bidders Specs Deviation if quoted by any bidder 1 1 Digital fax machin
90. ntent should be less than 67 PPM V V e Cylinder capacity i A type 0 75 cubic meter ii B type 1 5 cubic meter iii Bulk cylinder 7 0 cubic meter The Manufacturer firm should have WHO GMP DHQH ISI BIS registration certificate with a valid drugs licence and explosive License e 40 Cu FT B type high pressure seamless cylinder for medical OXygen gas e cylinder are ISI Marked confirming to 1S 7285 certified by the Bureau of Indian e Standards BIS and approved by the Chief Controller of Explosives CCOE Government of India e 10 2 Ltr Water Capacity 40 CU FT e Fitted with bull nose type valve as per IS 3224 and neck cap e Color Code of the cylinder should as per IS 3933 1966 with updating till date e Certificate from department of explosion Government of India to be provided for e Specified cylinder Filled with Medical Oxygen Gas Working Pressure 150 Kg e f cm2 at 15 deg C Hydraulic test pressure 250 Kg f cm2 Should cover Standard Warranty terms Not to be kept loose Should be marked as highly Inflammable Note The instrument to be supplied first time with set for oxygen delivery Log book must be submitted with the Cylinder for supply records and a service book for maintenance records The cylinder would remain property of manufacturer 98 44 Over Bed Side Table for Patient OVER BED TABLE HEIGHT ADJUSTABLE 1 Size Stainless Steel Top 760 mm L x 360 mm W50mm x 25mm approx Z MS tubular telescopic st
91. nticated catalogue manual will not be considered 136 8 8 Must submit user list and performance report within last 3 years from major hospitals 8 9 Back to back comprehensive warranty to be taken by the supplier from the principal to supply spares for minimum 10 years 58 Ventilator Neonatal Equipment Specifications for Ventilator Paediatric Neonatal UNSPSC Code 42272206 ECRI Code 14 361 1 Description of Function Technical Bidders Specs Deviation if quoted by any bidder 1 1 Paediatric Infant Ventilators provide artificial respiration support to infants and neonates in ICU Wards 2 Operational Requirements Technical Bidders Specs Deviation if quoted by any bidder 137 2 1 The Infant Paediatric ventilator should be easy to operate and should incorporate safety alarms and backup ventilation 2 2 Microprocessor Controlled integrated suitable for neonate and child ventilation 2 3 Demostration of the equipment whenever asked for 3 Technical Specifications Technical Bidders Specs Deviation if quoted by any bidder 3 1 Should have not less than 10 inch colored TFT screen for monitoring of the ventilation parameters curves and loops 3 2 Automatic compliance amp Leakage compensation for circuit and ET tube 3 3 Should have the facilities for following setting for neonate to child a Tidal Volume b Flow Pattern c Inspiration Plateau d Pressure ramp e SIMV Rate f CPAP PEEP g Pressure Su
92. ok with instructions for daily weekly monthly and quarterly maintenance checklist The job descriptin of the hospital technician and company service engineer should be clearly spelt out 8 7 Must submit user list and performance report within last 3 years from major hospitals 59 Wall mounted B P Apparatus The offered B P instruments should be in accordance with the international quality standards The BP instrument should be of superior quality The product should be European CE or USFDA approved with 3 years warranty Type Blood Pressure Monitor fitted on wall i e Accuracy 3mmHg Sub division 2mmHg Dial type mercury free manometer Measure scope 0 300mmHg 143 Washing Machine OO O Wash boad Kgs 65 amp Type of Washing Machine Fully Automatic Control Type JogDial Loading Type Front Wash Method Close Main Features Meaning Wash method refers to the various movements used by Tumble different washing machines to wash the clothes during their wash cycles There are different wash methods 1 agitator 2 pulsator 3 tumble 4 turbo drum 5 pulgitator etc Manufacturing companies try to replicate the movements of manual hand wash as closely as possible when designing their wash mechanisms It helps get clothes cleaner control water temperature 0 95 error indicator with wash programs delay sar up to 24 sees 5 mode spin control including no spin and 400 600 800 1000 rpm anti foam
93. olts 20 Amps Typically refrigerators operate about 1 3 of the time 1 3 duty cycle or 8 hours a day Therefore the A H drain will be 160 A H 8 hours x 20 Amps 160 A H a Aate nowsoacup Dimension 5 3mm Weight 2 Kg 5 1 i 06 3mm i 20 5 1 220 Sp Gr Litres Cell Warranty Standard Warranty 78 Warranty Standard Warranty 79 36 KMC Chair Specification fo KMC Chair Material Powder coated S S Frame Backrest should be adjustable according to need Hand rest on both sides is required Size As shown in picture Mattress Thickness of Mattress should be 5 Inches Mattress for the chair should be covered with Ragzin Linen shall not be used 80 BA LCD moniter 18 with LCD player DVD player with installation LCD Monitor Specifications Product features Contrast ratio 600 1 Contrast ratio Display LCD Display Screen Size min 18 or 1 inch more LCD display European CE or USFDA Approved Warranty Standard Warranty Installation included 38 Linen Trolley Soiled Linen Trolley Stainless steel Linen Bag size 510mm dia x H 700mmthe bag should be made up of Heavy duty nylon cloth Construction Two horizontal rings of 500mm dia made up of 20mm x 4mm thick stainless steel flat with three vertical supports of 25 mm dia x 1 2 mm stainless steel tubes mounted on 100mm dia rubber castors duly powder coated with PVC caps Each 8 MULTIPURPOSE STOOL
94. olymer material thickness of bin shall be minimum 2 5 mm 0 2 mm with foot operated lid and handles for lifting also refer IS 3730 1988 for details Lid mechanism shall be of SS material only CLASS amp SIZES SMALL 15 Lt 153 HDPE bucket of Circular Top of about 285mm 10mm without collar amp circular Bottom of about 230mm 10mm Height 290mm 10mm with suitably designed foot operated lid and proper handles for lifting the bin SS pipe wire rod used for cage handle and for operation of lid shall not be less than 4mm dia SS rod SS Square hollow pipe 2 Nos of 20x20 mm shall be provided at the bottom for steady placement of the bin DIMENSIONS SS pipe wire rod shall be not less than 4 mm dia WORKMANSHIP amp FINISH As per IS 3730 1988 for HDPE LLDPE bin SS parts shall be smooth finished proper rubber studs shall be provided on the paddle and both ends of 20mm SS square hollow pipe Lid of the Bin shall be foot operated and SS bottom rod of foot operated mechanism shall be minimum 8 mm It shall close to secure infected contents immediately upon releasing pressure Other requirements as per IS 3730 1988 REQUIREMENTS Bin shall be preprinted as per requirements of Bio Medical Waste Management Rules 1998 amended till date Material used shall preferably match all requirements under relevant IS code Ready to use Each
95. onitors data through hospital LAN via office PC in Hospital LAN Networkand or through dial up facility from remote location OPTIONAL CRT Slave monitors 21 inches in ICU one per central station Communications with Information Management Systems A To provide suitable facility for sending and receiving DICOM Compatible Radiological Images like Ultrasound X Ray etc to and from the monitoring network to and from Hospital Information System Radiology Information System etc for integration of various informations OPTIONAL Include Laser Printer and dual channel strip chart recorder 4 System Configuration Accessories spares and consumables 27 4 1 4 2 4 3 4 4 4 5 4 6 4 7 ECG Resp 5 Lead ECG Cable with clip 2 sets per monitor and 10 Lead ECG Cable with clip 1 set per monitor NIBP Adult cuff 2nos per monitor and two sizes of pediatric cuffs one per monitor complete sets SpO2 Adult SpO2 sensor with cable two nos per monitor and Pediatric SpO2 sensors one no per monitor IBP Include four nos per monitor of reusable pressure transducer with bracket holder and 100 nos disposble domes per monitor Temperature Rectal temperature probe two per monitor and skin temperature probe one per monitor Necessary cabling for networking the monitors on turnkey basis Necessary mounting solution mounting on any pendant for monitors 28 Technical Specs quoted by bidder Bidders Deviation if any
96. ottom rod of foot operated mechanism shall be minimum 8 mm It shall close to secure infected contents immediately upon releasing pressure Other requirements as per IS 3730 1988 REQUIREMENTS Bin shall be preprinted as per requirements of Bio Medical Waste Management Rules 1998 amended till date Material used shall preferably match all requirements under relevant IS code Ready to use Produced by an ISO 9001 2000 Certified Unit Each Bin shall be Marked Rajasthan Health Systems Development MARKING Project Govt of Rajasthan Properly labeled Bin to indicate Product Name Produced by Address Date of Manufacturing Size Batch Number Also refer IS 3730 1988 Each Bin shall be packed in poly film bag to reach destination PACKING amp PACKAGING securely Also refer IS 3730 1988 148 SPECIFICATION OF Plastic Bins Black Big Appendix S 4 NS 12 MATERIAL Plastic HDPE LLDPE bins made from virgin polymer material thickness of Bins bin shall be minimum 2 5 mm 0 2 mm with foot operated lid and handles for lifting also refer IS 3730 1988 for details Lid mechanism shall be of SS material only CLASS amp SIZES BIG 25 Lt HDPE bucket of Circular Top of about 340mm 10mm without collar amp circular Bottom of about 280mm 10mm Height 360mm 10mm with suitab
97. perational Requirements 102 Technical Bidders Specs Deviation if quoted by any bidder None 3 Technical Specifications Technical Bidders Specs Deviation if quoted by any bidder 3 1 Specification Mono Laser Jet Printer 1 Speed Min 20 PPM A4 2 Memory RAM Min 32 MB 3 Resolution 1200 1200 dpi 4 Paper Size A4 A5 Letter Legal with Compatible paper tray 5 Interface USB Ethernet UTP 6 Paper Handling Input Tray 250 Sheets min 7 Monthly Duty Cycle 10000 Pages 8 Languages Built in PCL5e PS2 or higher 9 Automatic duplex printing 10 Interface Cables amp Accessories 11 Drivers software in Linux amp Windows 4 System Configuration Accessories spares and consumables Technical Bidders Specs Deviation if quoted by any bidder 103 None 5 Environmental factors Technical Bidders Specs Deviation if quoted by any bidder 51 Shall meet IEC 60601 1 2 2001 Or Equivalent BIS General Requirements of Safety for Electromagnetic Compatibility or should comply with 89 366 EEC EMC directive 5 2 The unit shall be capable of operating continuously in ambient temperature of 20 30 deg C and relative humidity of 15 90 5 3 The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C and relative humidity of 15 90 6 Power Supply Technical Bidders Specs Deviation if quoted by any bidder 6 1 Power input to be 220 240VAC 50Hz fitted with Indian plug
98. pin 15 amp plug 01 in number iii Power cable 3 core lead of 5 meter along with one 3 pins 15 amp plug 01 in number iv The following spare parts per machine are also required Bottles lids rubber seals blades 2each and one number suction tubing set Environmental factors i It should meet IEC 60601 1 2 2001 equivalent BIS general requirements of safety for electromagnetic compatibility should comply with 89 366 EEC EMC directive ii The unit should be capable of stored continuously in ambient temperature of 0 502C and relative humidity iii The unit should be capable of operating continuously in an ambient temperature of 10 402C and relative humidity of 15 90 Power supply i The power input should be 220 240VAC 50 Hz fitted with an Indian plug ii A fuse a resettable circuit breaker of an appropriate capacity should be incorporated for protection of motor iii It should work on 220 240VAC as well as batteries The mains adaptor is to be supplied Standards safety and training i It should be FDA CE UL BIS approved product ii It should conform to BIS standard for suction apparatus IS 4533 Latest revision except where specified here differently iii Manufacturer supplier should have ISO certification for quality standards 44 Warranty iv There should be a comprehensive warranty for 3years Others i User technical maintenance manuals to be supplied in English ii Certificate of calibration and i
99. pport h FiO2 i Pause Time j Inspiration trigger sensitivity to flow amp pressure k Base Flow I Sensitivity for cycling to expiration 3 4 Should have the capability of monitoring of the following parameters a Airway Pressure b Expired tidal Volume 138 3 5 3 6 3 7 3 8 3 9 c Minute Volume d Spontaneous Minute Volume e Total Frequency f Fio2 g Auto PEEP h Rapid Shallow Breathing Index i Plateau Pressure j Inspiratory amp Expiratory Resistance k Static Compliance Imposed Work of Breathing m Peak Plateau and mean airway pressure Plateau Pressure Should have the Alarms User Selector for all the measured and monitored parameters Should have the following Modes of ventilations a Volume controlled b Pressure Controlled c Pressure Support d SIMV Pressure Control and volume control with pressure support e CPAP PEEP 0 30 CM H20 f Auto mode Auto flow preferable g PRVC h Biphasic preferable Sensors should be automatically calibrated every time it is switched on Should have the ability to calculate a Intrinsic Peep b Occlusion Pressure c Negative Inspiratory force Medical Air Compressor a Imported stand alone Medical Air compressor from the same manufacturer of ventilator b Snap fit with the Ventilator module to provide an oil free Medical air c Peak output flow should be minimum 160 LPM d Air quality should comply with ISO compressed air puri
100. prehensive standard warranty 7 4 Should have a minimum 5 star on Energy Saving Star band 8 Documentation SI Name Technical Bidders Specs Deviation if quoted by any 127 User Technical Maintenance manuals to be supplied in English 8 2 Certificate of calibration and inspection 8 3 List of important spare parts and accessories with their part number and costing 8 4 Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job descriptin of the hospital technician and company service engineer should be clearly spelt out 56 Jaundice Meter Transcutaneous Bilirubinometer ELECTRICAL SPECIFICATIONS Battery Number of measurements when fully charged Internal NIMH 250 AC adapter Input 100 V to 240 V 50 60 Hz 11 VA to 18 VA Output 9 VDC 500 mA Light source Pulse xenon arc lamp Light source life 150 000 measurements Sensors Silicon photodiodes 128 PHYSICAL SPECIFICATION Width 56 mm Depth 45 mm Height 168 mm Weight 203 g 10 PERFORMACE SPECIFICATIONS Measurement range 0 0 mg dL to 20 0 mg dL 0 umol L to 340 mol L Clinical Data Standard Error of Estimate SEE 1 5 mg dL or 25 5 umol L gt 35 weeks gestation 1 6 mg dL or 27 4 umol L 24 34 weeks gestation DATA TRANSMISSION USB port HL 7 or CSV AMBIENT CONDITIONS DURING OPERATION Temperature 10 to 40 50 F to 104 F Air pressure 700 hPa to 1060 hPa Altitude range 400 m to 3 000 m Relat
101. printed as per requirements of Bio Medical Waste Management Rules 1998 amended till date Material used shall preferably match all requirements under relevant IS code Ready to use Produced by an ISO 9001 2000 Certified Unit MARKING Each Bin shall be Marked Rajasthan Health Systems Development Project Govt of Rajasthan Properly labeled Bin to indicate Product Name Produced by Address Date of Manufacturing Size Batch Number Also refer IS 3730 1988 PACKING amp PACKAGING Each Bin shall be packed in poly film bag to reach destination securely 151 Also refer IS 3730 1988 SPECIFICATION OF Plastic Bins Blue Big Appendix S 4 NS 14 MATERIAL Plastic HDPE LLDPE bins made from virgin polymer material thickness of Bins bin shall be minimum 2 5 mm 0 2 mm with foot operated lid and handles for lifting also refer IS 3730 1988 for details Lid mechanism shall be of SS material only CLASS amp SIZES BIG 25 Lt HDPE bucket of Circular Top of about 340mm 10mm without collar amp circular Bottom of about 280mm 10mm Height 360mm 10mm with suitably designed foot operated lid and proper handles for lifting the bin SS pipe wire rod used for cage handle and for operation of lid shall not be less than 4mm dia SS rod SS Square hollow pipe 2 Nos of 20x20
102. rah to be equipped with bolting device with tongue in groove inter locking mechanism with six lever lock Three hinges in each door Door stiffener from inside to its full height in top hat section size 75mm width Paint Enamel paint of standard make like Asian Berger Reband Three colour choices may be given In overall size 10 mm amp thickness of sheet etc as per Indian Standard 11 Microphone Loudspeaker Pre Tone and Power amplifier Volume Controls Amplifier Amplifier amplifier modifies larger current based on smaller current International Norms The international Noise Council recommends that the noise level in an ICU be under 45 dBAin the daytime 40 dBA in the evening and 20 dBA at night dBA is a scale that filters outlow frequency sounds and is more like the human hearing range than plain dB Program Sound Amplifier Bidder Company shall ensure that the program sound amplifier delivery audio signals to the high fidelity loudspeaker system and video signals to a local display conform as a minimum to the following specifications a 90 watts per channel minimum b total harmonic distortion less than 1 rated power c frequency response analog 10hz 100khz 3db d frequency response digital 10Hz 45KHz 3dB e S N 95dB or greater f controls separate level controls on inputs master level control and separate base treble adjustments and g inputs outputs
103. reventive maintenance test as per guidelines provided in the service maintenance manual A5 Comprehensive warranty for 3 years and provision of CMC for next 3 years 8 Documentation Technical Bidders Specs Deviation quoted by if any bidder 8 1 User Manual in English 30 8 2 8 3 8 4 8 5 8 6 8 7 Service manual in English Must submit user list and performance report within last 3 years from major hospitals Compliance Report to be submitted in a tabulated and point wise manner clearly mentioning the page para number of original catalogue data sheet Any point if not substantiated with authenticated catalogue manual will not be considered List of Equipments available for providing calibration and routine Preventive Maintenance Support as per manufacturer documentation in service technical manual List of important spare parts and accessories with their part number and costing Log book with instruction for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out 31 Revolving chair with armrests made of PVC material with chromium plated covering and also having cushioned arms covered with best quality leather foam that suits all climatic conditions The seat and back rest are made of 12mm thick steam press molded ply having polyurethane foam of right density duly upholstered with best qualit
104. rge arrestors and filters All necessary power supply s s o s etc required for the operation of the sound equipment shall be designed supplied and installed by the contractor 5 EMERGENCY OVERRIDE UNIT The emergency override unit when activated from the Fire Command Center it will override all incoming signals to allow emergency messages to pass through 6 SYSTEM TESTING The contractor shall test the system in the presence of the Superintending Officer to show that its performance satisfies the requirement of this specification All test equipments shall be professional and supplied by the contractor A sound pressure meter will be required No claim is allowed for this test The cost shall be deemed to be included in the schedule of rates for the equipment LIST OF APPROVED MAKE PUBLIC ADDRESS SYATEM BOSCH BOSE AHUJA Warranty 3 years with 3 years AMC 95 Pulse Oxymeter multi channel monitor Adult amp Pediatric Pulse Oximeter Sr No Description Salient features Compliance Deviation if any Yes No It should be table model lightweight compact amp portable with following features 110 2 It should have 12x1 2Ahv rechargeable battery with at least 8 hours Battery Backup 3 Power supply 230v AC 50 Hz 7 4 It should have both adult amp pediatric including _ neonatal monitoring modes 5 SpO2 e Range 0 to 99 e Resolution 1 e Accuracy z 2 to 3 6 2 Pulse rate e Range 20 300 BPM
105. ropean CE US FDA approved Specifications of GLUCOSE STRIPS Should be able to use capillary blood samples Should have a minimum 4 months shelf life after opening the strip vial All strips should have at least one year expiry date from the date of supply 50 strips should be supplied along with the equipment Strips should be available in the local market Lancet One lancet Gun to be provided free with each equipment along with 50 strips and 50 Lancets The Bidders should quote the cost of Strips and Lancets for 8 000 tests per year per Glucometer for 3 years The above cost shall be considered for the purpose of evaluation together with cost of Glucometer The Bidder should quote the Unit Price of pack of 50 Strips and 50 Lancets 61 Warranty Standard Warranty Ee Hot air oven Equipment Specifications for Hot Air Oven Technical Bidders Specs Deviation if quoted by any bidder 1 1 Hot Air Oven is required for heating a sample under controlled conditions SI Name Technical Bidders Specs Deviation if quoted by any bidder 2 1 Microprocessor based system with PID temperature controller with integrated auto diagnostic system with fault indicator 2 2 Thermostatically controlled system 62 Technical Bidders Specs Deviation if quoted by any bidder Sel 3 2 323 3 4 3 5 3 6 3 7 External Stainless Steel Casing w x h x d 850 x 600 x 700 mm All dimensions will have a tolerance o
106. roved product 7 4 Shall meet the safety requirement as per IEC 950 OR Equivalent standard 8 Documentation Technical Bidders Specs Deviation if quoted by any bidder 8 1 User Technical Maintenance manuals to be supplied in English 8 2 Certificate of calibration and inspection 8 3 List of important spares and accessories with their part number and costing 8 4 Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job descriptin of the hospital technician and company service engineer should be clearly spelt out Warranty 3 years 24 Equipment Specifications for Complete Monitoring System for ICU REVISED Technical Bidders Specs Deviation quoted by if any bidder 1 1 Critical patients need to be monitored continuously in ICU at the bedside as well as at the central nursing station Technical Bidders Specs Deviation quoted by if any bidder 2 1 ICU should comprised of monitors at the bedside and with central station 2 2 Capability of storage of patient data and printing of patient reports 2 3 Demonstration of the equipment is a must 25 Technical Bidders Specs Deviation quoted by if any bidder 32 1 Minimum 15 inches multicoloured TFT display screen 3 2 Separate CPU Module rack 3 3 Eight digital and waveforms traces display 3 4 Combination of single dual and multiparameter modules 3 5 Parameter modules freely exchangeable betwee
107. rs operate both on mains power and on a 24V battery power supply for emergency back up with automatic switchover Amplifier front panel with LED shall shown as an indicator when it operates on the battery or AC supply The power amplifier shall be with the following approval e EMC emission acc to EN 55103 1 e EMC immunity acc to EN 55103 2 PERFORMANCE e Frequency response 50 Hz 20 kHz 1 3 dB 10 GB ref rated output e Distortion lt 1 rated output power 1 kHz INPUTS e Line input 3 pin XLR 6 3mm phone jack balanced e Sensitivity 1 V e Impedance 20 kOhm e CMRR gt 25 dB 50 Hz 20 kHz e Line input 1 2 3 pin XLR balanced e CMRR gt 25 dB 50 Hz 20 kHz e 100V input Screw unbalanced e Sensitivity 100 V e Impedance 330 kOhm OUTPUTS e Line loop through output t 3 pin XLR 6 3mm phone jack balanced e Nominal level 1 V e Impedance direct connection to line input e Line loop through output 1 2 3 pin XLR balanced e Impedance direct connection to line input e Loudspeaker outputs Screw floating e Output power 24 V 109 e Battery operation 1 dB ref rated power ENVIRONMENTAL CONDITIONS e Operating temperature range 10 to 550C e Storage temperature range 40 to 700C e Relative humidity lt 95 4 POWER SUPPLY The contractor shall make provision for all necessary power supply units voltage regulators etc to ensure that the equipment will perform satisfactorily c w necessary su
108. sors and other instruments must be the concentrically shouldered type countersunk flush with or slightly below the surface or rounded smooth and flush at the periphery but not riveted The screws must retain their position after setting without binding or loosening during use i Scissors i The ROCKWELL hardness of the finished instruments must be within the range from 50 HRC to 58 HRC Opposite blades must not vary in hardness by more than 4 units on the ROCKWELL C hardness scale ii Scissors must have joints which move smoothly and must be neither too loose nor too tight it must be possible to close and reopen the instrument easily with two fingers iii The cutting ability of the instrument must be tested The instrument must cut clearly without tearing iv The finish and all edges and surfaces must be uniform and free from burrs sharp edges except where required pores crevices gin marks rough areas cracks and overlaps j The instruments must be supplied free of residual scale acid grease and grinding and polishing materials and workmanship must be first class throughout Instruments must be free of defects that would detract from their appearance or impair serviceability proper functioning and intended use LIST 2 Contents Annexure B Sr No Equipment description for Maternal Health amp Paed Mat Ann Tentative Estimated Child He
109. sure Controlled Slow Suction Machine Electrically operated pressure controlled slow suction machine To extract fluid from body during emergency treatment i It should have Crompton Greaves American Universal GEC Motor of minimum HP capacities ii The machine should be portable on four wheels and handle for transportation iii The suction pump should be oil immersed fitted on motor shaft iv It should have line grinding internally v To facilitate maintenance the cover of machine should be easy to open from the top and sides 43 vi The suction machine should be capable of producing minimum vacuum of 500 approximately mm Hg which should be adjustable and monitored by vacuum gauge of suitable range The suction capacity should be 15L per minute and can be regulated vii It should have two bottles of 1Liter with synthetic rubber lids The bottle shall be fitted with the arrangement to prevent overflow of fluid viii On Off switch and power indicator should be available ix Body material base top and panel should be made of rustproof and corrosion resistant moulded ABS stainless steel The jar bottle material autoclavable polycarbonate x Inbuilt maintenance free battery The battery backup up to60minutes on full charge It should be provided with cable for ambulance car use xi Systems configuration accessories spares and consumables i System as specified ii There should be a core lead of 2 meter along with one 3
110. te system including x ray tubes and electronic items and all parts for which order will be placed with an undertaking of 98 uptime and extension of CMC period by double the downtime if it exceeds more than 2 S N Documentation Reply Comments 8 1 User manual in English 8 2 Service manual in English 8 3 List of important spare parts and accessories with their part number and costing 8 4 Certificate of calibration and inspection from factory 92 8 5 Log book with instruction for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out Warranty 3 years with 3 years CMC 40 e Overall size 195 L x 92 W x 60 H cm e Available with mattress e High density foam ILD 48 58 Ibs 50sq e Thickness 6 e Cover with venlylized nylon cover with Zipper e Cover is antibacterial anti static acid resistant waterproof and meets fire regulation cades 16CFR1633 amp 16CFR 1632 41 N20 Cylinder fo Boyles NITROUS OXIDE supplied in a cylinder e Should be certified for medical use as an inhalation analgesic as per IP 1996 e Should not contain less than 99 0 V V of Ntrous oxide in liquid gaseous phase e Should contain less than 10 PPM V V of carbon monoxide e Should contain less than 300 PPM V V of carbon dioxide e Should contain less tha
111. tinuous operation mode EMC IEC 60601 1 2 2007 10 Operating conditions 10 C to 40 C 15 RH to 85 RH 800 hPa to 1060 hPa 11 Storage conditions 15 C to 60 C 10 RH to 95 RH 12 Dimensions standard 13 Weight standard 14 USFDA Approved with CE certificate 6 Bubble C PAP 15 Bubble CPAP Servo controlled Humidifier base with digital temperature display alarms for conditions like high amp low temperature humidity amp disconnections Compressor Air Auto feed Humidifier Chamber with constant compressible volume to maintain CPAP pressure Reusable Humidifier if reusable 6 with each machine if disposable 300 Heated Breathing Circuit Silicon with heater wire technology to provide proper humidification if Reusable 6 with each machine if disposable 300 Temperature amp flow sensor Temperature amp flow sensing of airway and humidifier chamber with feedback mechanism CPAP generator with adjustable CPAP from 3 to 10 cmH20 with generation of Bubbles at least 10 extra generator with each machine Safety provision for maximum pressure limiting in case of occlusions pressure damping filter Facility for pressure monitoring amp delivery FiO2 monitoring Non invasive Interface should include a Nasal Tubing to hold the nasal prongs b Argyl Nasal Prongs of silicon in various sizes based on nasal diameter amp width of septum c Infant Bonnets Caps of different sizes to fit on head to hold nasal tubing amp
112. ty class 139 3 10 e Medical Air Compressor should automatically activate in the event of wall air supply loss f Replacement of internal filters should be performed without removing the compressor g Should have washable air filter Nebuliser with capability to deliver particle size of lt 3 micron amp to be used in both Off and On line 4 System Configuration Accessories spares and consumables Technical Bidders Specs Deviation if quoted by any bidder 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4 10 Infant Paediatric Ventilator 01 Humidifier Servo controlled with digital monitoring of inspired gas temperature complete with internal heating wire O1 Nebulizer compatible with ventilator 01 Medical Air Compressor Air Hose 01 Oxygen Hose 01 Paediatric autoclavable reusable silicone breathing circuit 02 Infant autoclavable reusable silicone breathing circuit 02 Filter paper for humidifier for 100 uses 01 Non corrosive trolley and hinged arm 01 140 5 Environmental factors Technical Bidders Specs Deviation if quoted by any bidder 5 41 Shall meet IEC 60601 1 2 2001 Or Equivalent BIS General Requirements of Safety for Electromagnetic Compatibility 5 2 The unit shall be capable of operating continuously in ambient temperature of 10 40deg C and relative humidity of 15 90 5 3 The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C an
113. unit shall be capable of operating continuously in ambient temperature of 30 C and relative humidity of 80 5 2 Proper X Ray shielding should be provided for the main equipment 5 3 Pre Requsites should be clearly spelt out in terms of Mammography room requirements S N Power supply Reply Comments 6 1 Suitable Power input to be 220 240VAC 50Hz OR 440 V 3 PHASE fitted with Indian plug 90 6 2 Resettable overcurrent breaker shall be fitted for protection 6 3 Spike protector of appropriate rating should be provided 6 4 UPS of 30 minutes back up of suitable rating conforming to IS 302 shall be supplied S N Standards and safety Reply Comments 7 1 Should be FDA or CE approaved product 7 2 Electrical safety conforms to standards for electrical safety IEC 60601 IS 13450 7 3 Safety aspects of Radiation dosage leakage should be spelt out 7 4 Phantom for calibration should be provided 7 5 Should comply with AERB Guidelines for radiation leakage 7 6 Comprehensive guarantee for 3 years of complete system 91 including x ray tubes and electronic items and all other parts for which order will be placed with uptime warranty of 98 Comprehensive Guarantee period will be extended by double the downtime if it exceeds more than 2 in a year 7 7 Rates of comprehensive CMC for comple
114. with card Native resolution 1024x768Color Pixels Minimum Intelligent resizing 1280x1024 Key stone Lens shift Digital Packing Hard case high Impact durable case for LCD Projectors 4 System Configuration Accessories spares and consumables 22 Technical Bidders Specs Deviation if quoted by any bidder 4 1 Accessories 1 Standard accessories power cord RGB cable Video Audio Cable Component Cable PS 2 mouse cable remote controller 2 Replacement lamp Optional Accessories One spare replacement lamp of life 2000 hours to be provided cost to be indicated separately in the offer 3Ceiling mount brackets Optional Accessories To be provided cost to be indicated separately in the offer 5 Environmental factors Technical Bidders Specs Deviation if quoted by any bidder 5 1 The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C and relative humidity of 15 90 5 2 The unit shall be capable of operating in ambient temperature of 20 30 deg C and relative humidity of less than 70 6 Power Supply Technical Bidders Specs Deviation if quoted by any bidder 6 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 23 7 Standards Safety and Training Technical Bidders Specs Deviation if quoted by any bidder Fil Manufacturer should be ISO certfied for quality standards 7 2 Should conform to FCC Class B 7 3 Should be FDA CE UL BIS app
115. y leather foam The back having special contours for better back support The chair provided with pneumatic seat height adjustment with lever having cushioning effect and swivel mechanism The seat amp back having tilt locking and tilt tension can be adjusted according to preferences The chair having 700mm chromium plated metal base provided with twin wheel castors nylon Dimensions Width 500 mm Height 1100 mm Depth 700 mm Seat Height 500 600 mm Seat Size 450x470 mm Computer Desk top Computer preloaded with Microsoft Standard Edition Office Std 2013 INC OLP C Gov during installation 1 Processor Intel Core i5 or AMD Phenom X4 or equivalent processor Single Dual Core with Multi Thread per core Quad Core or more core 64 bit x86 processor The processor should be fully binary compatible to 32 bit applications A Dual Core with Multi Thread Quad Core or more cores on a single die socket will be treated as a single processor The Processor should be PC Mark 7 benchmarkedfor Productivity Score in the range of at least 1850 to 1900 with 4 GB memory 2 Mother Board Suitable chipset for quoted processor based motherboard with minimum one PCle amp one PCI PCI x slots Motherboard should be of Small Form Factor SFF Micro ATX form factor 3 Memory 4GB DDR 3 1333 MHz or higher expandable up to 16GB 4 Monitor 18 5 19 LCD LED TFT Monitor or higher Same OEM make and Color Monitor Built in Exter
Download Pdf Manuals
Related Search
Related Contents
TEMPPO Designer (IDATG) Frigidaire 134126300B Washer/Dryer User Manual LOG WINDOW (4.03.04) Users Manual user manual - CNET Content Solutions Fixed Network Camera Hardware User Manual Cadillac 2008 Escalade Automobile User Manual User Manual - Delta AC Drives 9901-UDX Product Manual V1.17 Copyright © All rights reserved.