1. 6 8 9 Printer optiona STEP 1 Unpack the scale system and check parts against the PACKING CHECKLIST If there are any missing or damaged parts please call the service hotline at 1 800 654 6360 STEP 2 Figure 1 Verify that the serial number on the Display Unit 1 matches that on the Base Assembly 2 STEP 3 Remove the four 4 set screws from Base Assembly collar and apply a small amount of Loctite to each Insert Mast 3 into Base Assembly collar and seat firmly Re install set screws in Base Assembly collar and tighten securely NOTE If an optional printer has been ordered go to Page 6 INSTALLING OPTIONAL PRINTER before proceeding STEP 4 Feed the display cable down through the Mast and pull out through the Base Assembly STEP 5 Remove the set screws from the Display Unit collar Set the Display Unit squarely on top of the Mast with the display label facing the scale platform Apply a small amount of Loctite to the four 4 set screws and reinstall the set screws tightening securely Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _130314 Page 5 of 20 ASSEMBLY cont d STEP 6 Figure 2 Lay the system on its side a
2. 20 5 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i 130314 Page 13 of 20 BATTERY REPLACEMENT WARNING DO NOT remove batteries while scale is on Allow scale to shut down naturally thru timing out This prevents possible voltage drain on the printed circuit board coin battery STEP 1 The display will read CHANGE BATTERIES STEP 2 Figure 8 Place the scale on its side and open the battery compartment cover located in the bottom of the scale base STEP 3 Remove and replace ALL six 6 C cell batteries Refer to diagram on the battery compartment cover for placement STEP 4 Press the WEIGH button to confirm display is working STEP 5 Tightly close the cover STEP 6 Zero the system Figure 8 Bottom of Scale Base SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _ 130314 Page 14 of 20 THEORY OF OPERATION SR Instruments patient weighing systems are digital scales Strain gauge force cells convert the force of an applied weight into an analog
3. Be sure to use proper handling precautions at all times SETTING CALIBRATION NOTE Ensure that nothing is in contact with the scale system during this procedure Remove hands from the system when noting the displayed calibration results STEP 1 Remove the four 4 screws on the bottom of the display housing Lift the display panel Put the scale system into the Calibration Mode by switching the calibration switch on the display board Figure 10 CALIBRATION will flash on the display STEP 2 Select two 2 known calibrated weights traceable to NIST NOTE The first weight should be at least 500 pounds half of the maximum scale capacity The second weight should be less than half of the first weight DO NOT USE barbells or uncalibrated weights STEP 3 Press the MENU button until FULL 1000 00 Lb is displayed Set the FULL value of the first selected calibrated weight Use the UP arrow button to select the digit and the DOWN arrow button to change digit Press ENTER to save changes STEP 4 Press the MENU button until HALF 500 00 Lb is displayed Set the HALF value of the second selected calibrated weight Use the UP arrow button to select the digit and the DOWN arrow button to change the digit Press ENTER to save changes STEP 5 Press MENU button until 3 Pt Calibration is displayed Press the UP arrow button STEP 6 Zero the scale by removing all weight from the platform Press the UP arrow button
4. DIAgram cisessiccsceccisassccdacscsedcicassaseccdesscsdeasseadecsssccddcadsosescdeseceieasses 15 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i 130314 Page 3 of 20 PACKING CHECKLIST SR555i Stand On Scale DESCRIPTION Box 1 BASE ASSEMBLY FIVE 5 SET SCREWS IN PLACE ea MAST ea N QUANTITY DISPLAY UNIT WITH CABLE FIVE 5 SET SCREWS IN PLACE ea PACKAGE OF SIX 6 C CELL BATTERIES ea LOCTITE ea 1 8 ALLEN WRENCH ea QC INSPECTION SHEET ea CALIBRATION CERTIFICATE ea WARRANTY CARD ea MANUAL ea Box 2 Optional Handrail and or Optional Height Bar OPTIONAL HANDRAIL SET WITH HARDWARE ea OPTIONAL HEIGHT BAR ea Box 3 Optional Printer Kit PRINTER ea PRINTER BATTERY CHARGER ea PRINTER CABLE lea PRINTER MOUNTING COLLAR amp HARDWARE lea PRINTER MOUNTING BRACKET amp HARDWARE lea PRINTER PAPER lea LOCTITE lea SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _130314 Page 4 of 20 Figure 1 ASSEMBLY Assembly Diagram 4 Cable Clamp
5. continuous weigh and for AutoHold the micro controller performs checks for signal stability before locking in on the reading If the data variance is greater than 0 1 in the AutoHold mode the micro controller will reset the filter and start a new filtering period The micro controller can be placed in a calibration mode where the system can be re calibrated In the calibration mode the system slope is calculated from two points zero and full scale in the 2 point calibration mode or the slope and change in slope is calculated from three points zero half and full scale in the 3 point calibration mode SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _ 130314 Page 15 of 20 CALIBRATION NOTE Ensure that nothing is in contact with the scale system during this procedure Remove hands from the system when noting the displayed calibration results CHECKING CALIBRATION CALIBRATION TOLERANCE TABLE STEP 1 Select two 2 known calibrated weights traceable to NIST pits 2 pus NOTE The first weight should be at least 500 pounds half of the 99 9 100 0 maximum scale capacity The second weight should be less than half 200 0 2002 of the first weight DO NOT USE barbells or uncalibrated weights 300 0 300 3
6. STEP 2 Zero the scale by pressing and holding ZERO WEIGH TT E PUO 00 0 600 6 STEP 3 Place the first calibrated weight on the scale Wait for scale to 00 0 700 7 stabilize note scale reading Remove weight 800 0 800 8 STEP 4 Place second calibrated weight on scale Wait for scale to 899 1 900 0 900 9 stabilize note scale reading Remove weight 999 0 1000 0 1001 0 STEP 5 The scale readings for both weights should be within the Figure9 Calibration Calibration Tolerance Table Figure 9 Tolerance Table IMPORTANT CALIBRATION Qualified service personnel only should perform this procedure The SR5537 load cells have no user serviceable components and should not be tampered with for any reason Re calibration is generally not required but should be verified periodically to ensure accuracy The recommendation for calibration check is at least once every 12 months or as individual maintenance policy requires Figure 10 Calibration Switch Diagram Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _ 130314 Page 16 of 20 CALIBRATION cont d CAUTION The integrated circuits and semiconductors on the printed circuit boards may be damaged by electrostatic discharge ESD
7. STEP 7 Place the HALF weight from Step 4 on platform Allow weight to stabilize Press UP arrow to save change Remove weight STEP 8 Place the FULL weight from Step 3 on platform Allow weight to stabilize Press UP arrow to save change Remove weight STEP 9 Press ENTER to save the calibration or WEIGH to exit without saving STEP 10 Switch the scale system out of the Calibration Mode on the display board Figure 10 STEP 11 Place the display panel into the display housing Align the display panel with the four holes in the display housing Secure display panel with the four 4 mounting screws SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i 130314 Page 17 of 20 CONFIGURING SEND BUTTON STEP 1 Press the MENU key until DATA OUT PRINT is displayed STEP 2 Press UP or DOWN key to select between EHR and PRINT STEP 3 Press the ENTER key to save EHR OUTPUT Electronic Medical Records EMR Electronic Health Records EHR technology is supported by the i series scales from SR Instruments The EMR EHR software is not included with scale There are many different EMR EHR software available and the connectivity of the scale to the software requires the services of a professiona
8. Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _ 130314 Page 1 of 20 SR Scales by SR Instruments Inc Model SR555i Stand On Scale System Operating and Service Manual Serial Numbers 1000 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _ 130314 Page 2 of 20 TABLE OF CONTENTS TABLE OFTIGURES iiases corsswes sen cecescenssraserncucesverssnsscensacessereintancncncessensinsauecauceseumsannatensnsesseneansauexeaces 2 IN GE Wr c 3 N10 Py fre d REPLACEMENT PARTS AND ACCESSORIES ccce ecce eee eee teet ettet ette teet etes asa aas 7 SYSTEM DESCRIPTION AND INTENDED USE cssssssssssssecscscsecsscsesdssatecsecesesesdscesecsecsacseddscasecseae 7 MAINTENANCE AND OMG ASIN Ga css rere 0080006902 vaca 00000970209 00 19 O 0000902000933 000009029209 0018 Eoo Ee nensis 8 SIORAGEANDIRANSPOREA LION 55 2 2 1 2 2 1 3 20 22 620202 2 0952216 2220262 2220 2202420202 2 2020 EES 8 SPECIFICATIONS m 9 BUTTON WING ERODING 201 1 92 120 0008091220389 01S DEEREIE EDI ECOLE DOR EE COD EE EIE DEP 10 BASICSYSTEM OPERA TTON P M S 11 BA LIER Y RE PIA CEIVIENN T
9. NDRAILS STEP 1 Figure 4 Attach top of each of the Handrails 6 to the bottom right and left of the Display Unit 1 Use two 2 screws and two 2 split lock washers on each side slightly tighten Do not tighten all of the way STEP 2 Attach the bottom of the Handrails to the right and left side of the Base Assembly 2 using one 1 screw and one 1 split lock washer for each handrail Tighten all six 6 screws securely INSTALLING OPTIONAL HEIGHT BAR STEP 1 Figure 4 Remove the set screw on the back of the Display Unit 1 and in the Base Assembly 2 STEP 2 Slide the Height Bar 7 down through the hole in the Display Unit and seat firmly into the Base Assembly Apply a small amount of Loctite to the two 2 set screws and reinstall tightening securely INSTALLING OPTIONAL PRINTER STEP 1 Figure 4 Slide the Printer Mounting Collar 11 over the Mast 3 Position the Printer Mounting Collar approximately 5 inches from the top of the mast Tighten the two 2 set screws to secure the Printer Mounting Collar to the Mast NOTE The three 3 holes on the Printer Mounting Collar should be towards the top of the Mast Figure 5 Figure 6 Handrail Height Figure 4 Printer Mounting Figure 5 Printer Mounting Bar Diagram Collar Bracket Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyrigh
10. ale output Use the UP or DOWN arrow buttons to select between PRINT and EHR Press ENTER to save changes Setting printout orientation Use the UP or DOWN arrow buttons to select between PRINT INVERTED and PRINT NORMAL Press ENTER to save changes UP UP Press UP to adjust height up from the default to increase the scale s on time or to A selecta digit when setting time and date SELECT DOWN bown Press DOWN to adjust the height down from the default to decrease the scale s on time or to change the value of a selected digit when setting time and date CHANGE BASIC SYSTEM OPERATION SETTING SYSTEM ZERO Make sure the scale 1s free and clear of any obstructions and press and hold the ZERO WEIGH button The displayed message will indicate HOLD TO ZERO and count 0 down to zero Make sure that nothing is in contact with the scale while zeroing the system In a few seconds the display will read WT 0 0 Lb or Kg This action also resets previously stored weight height and BMI values to zero Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _ 130314 Page 12 of 20 BASIC SYSTEM OPERATION cont d WEIGHING Position the patient on the
11. erie EEEE EEEE AEE ERER 13 THEORY OF OPERATION cr E O E 14 CALIBKATION Rer R M 15 CONFIGURING SEND BUT ION Gioia cos isdsd6diis0a i019 p iaaa PIT c2 ab redo dv2iirueoe 17 TROUBLESHOOTING 5 322 02999225219 85 v9 2222 1 FIVE E OEIL UE RE EEEET Pet eEEXEEPIEN FEEEEEE MEER EFIE ET Pep EEe 18 13 469 gb f n 19 TABLE OF FIGURES Piore Assembly DIQPEOI sssrin E Eee Peto p PIU LUE PSbXRI IEEE HIS Pe DO ELE DI UE EPUVI j Figure 2 Cable Clamp and Display Cable Connector eee e ee eee eee ee eee eene 5 Risure 5 Battery Compartment Cover iiir tice rad Enn apr PUSH YR HERES e EY PE VV EN PE EUNS dud ERU EH ER eH dRR e EYV PE deP IUE 5 Figure 4 Handrail Height Bar Diagram eee ecce eee eee e eee eee eee e esee esse stets eee eeesous 6 Figures Prmter Mounting nn Er n ee 6 Pieure Printer Mounting BEAICKGL oie nti eh EIE Y YR SERRE HEY ERES RES Fe ERE EEEcHV IEEE reki onioni ansen kakia 6 Poorts Button DISDIdy uiiscseoe voies ibo E ERREEER ERE PEDE AES IEEE PEIEPERUREEXURU FS CRY EE DUAE REP ERINUUU EL REQUE RD TYEE POM U IE 10 PIQUE S Bottom OF Scale DiS eeoeic osa tirano p oae n ado suae aano Royan a oo eoa n0 Doo u na dog une ean Toa sooo uar oo eno s aora ou iaa 13 Figor 9 alibration Tolerance T3DIG uio rae Ev EAE ELE FEHEEER EE EXER Y EO n ie E Dex Ee Pel Y LX EE 15 Figure 10 Calibration Switch
12. eturned because of an error on the part of SR Instruments Inc e Noreturns accepted after 60 days SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _ 130314 SR Scales by SR Instruments Inc Page 20 of 20 Precision amp Technology in Perfect Balance SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc
13. l A null modem cable is required to communicate with the scale Scale output when send button is configured to Electronic Health Records 1s as follows lt esc gt R lt esc gt Wnnn n lt esc gt Hmmm m lt esc gt Bkk k lt esc gt Uuu lt esc gt E Where R is read W is weight nnn n is the weight in Lb or kg H is height mmm m is the height in inches or cm B is BMI kk k is the BMI U is units Ib or kg in or cm uu is LB or KG E 1s end of packet SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i 130314 Page 18 of 20 TROUBLESHOOTING SYMPTOM REASON CORRECTIVE ACTION Press the WEIGH button or remove one battery Wait five seconds then re install the battery and try the WEIGH button again The characters only appear on half of the display The display lights appear to work but do Check to ensure the membrane switch label is correctly not respond to button activation plugged into display board Check to ensure the calibration switch is not in the Calibration Mode Figure 10 The display shows no reading at all Check to ensure batteries are installed correctly see directions for BATTERY REPLACEMENT Check display cable to make sure it is connected securely For additional information or assi
14. nd remove the Cable Clamp 4 from the Base Assembly Attach the Display Cable Connector 5 to its mate in the Base Assembly STEP 7 Figure 2 IMPORTANT Reinstall the Cable Clamp Set the display cable into the groove under the Cable Clamp and reinstall the Cable Clamp leaving just enough slack to alleviate any tension on the Display Cable Connector Securely tighten the Cable Clamp screw Slide the extra cable back up into the Figure 2 Cable Clamp and Display Cable Connector Mast Excess cable MUST NOT contact the floor p SR 3553 by SR Instruments Inc 400 Young Set Yorcwarrio uie gin anseia guess OU To replace batteries open this cover plate and replace ALL SIX batteries as shown SERVICE and TECHNICAL HELP TEL 800 654 6560 FAX 716 693 5854 Made MODEL No Figure3 Battery Compartment Cover STEP Figure 3 Open the Battery Compartment cover and install the six 6 supplied C cell batteries as indicated on the cover diagram Close the cover and tighten thumb screw STEP 9 Return the scale to the upright position Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i 130314 Page 6 of 20 ASSEMBLY cont d INSTALLING OPTIONAL HA
15. scale Press the ZERO WEIGH button The weight stable indicator LU flashes on the display When the weight is stable the weight stable indicator remains solid The display will indicate the patient s weight in either pounds or kilograms example WT 123 5 Lb The stable weight is auto stored in memory NOTE If patient will be using a cane for support on the scale place the cane on the scale while zeroing the system This will ensure that the patient s NET weight will be displayed It is recommended that the system be zeroed prior to each new patient CALCULATING BMI Press to calculate BMI When the BMI button is pressed the default starting value 1s set either to 65 in or to 165 cm example HT 65 in Use the UP or DOWN arrows to adjust the default height to the value of the patient s height NOTE To calculate the BMI a patient s stable weight needs be stored as indicated in WEIGHING above if no stable weight has not been stored NO WEIGHT DATA will be displayed and the display will then go back to the weigh screen WT 0 0 Lb Press ENTER to save height data and display BMI calculation The BMI will be displayed example BMI 20 5 RECALLING LAST STABLE WEIGHT o RECALL Press to recall last stable weight The display will scroll thru WT HT and BMI stored values in approximately two second intervals example RCL WT 123 5 Lb RCL HT 65 in and RCL BMI
16. signal This signal is amplified by an operational amplifier and converted to a digital signal by an on chip analog to digital converter The digital signal is filtered converted to appropriate units and displayed on the liquid crystal display Strain gauge force cells each contain four strain gauges mounted in a full Wheatstone bridge configuration These bridges convert the physical movement of the force cell due to the applied mass on the system into minute changes in electrical resistance These changes in resistance produce a voltage difference across the Wheatstone bridge which is amplified by the operational amplifier The amplifier is configured to current sum the output of each cell with potentiometers serving to normalize the sensitivity voltage out per unit of weight applied of each bridge The offset potentiometer produces a small current which nulls the output of the amplifier for an unloaded system The output of the operational amplifier is digitized by the analog to digital converter The sigma delta converter sums a rapid sequence of O s 0 volts and I s reference voltage to achieve balance with the input signal from the amplifier The micro controller filters the digital output of the analog to digital converter subtracts the value saved during the system zero operation and scales the filtered output and then displays the result on the liquid crystal display The micro controller performs a moving median filter of data for
17. stance telephone our Service Hotline 1 800 654 6360 or e mail sri srinstruments com SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN5557 _130314 Page 19 of 20 WARRANTY FOUR YEAR LIMITED WARRANTY Each SRS H es system is manufactured with high quality components SR Instruments Inc warrants that all new equipment will be free from defects in material or workmanship under normal use and service for a period of four 4 years from the date of purchase by the original purchaser Normal wear and tear injury by natural forces user neglect and purposeful destruction are not covered by this warranty Warranty service must be performed by the factory or an authorized repair station Service provided on equipment returned to the factory or authorized repair station includes labor to replace defective parts Goods returned must be shipped with transportation and or broker charges prepaid SR Instruments Inc s obligation 1s limited to replacement of parts that have been so returned and are disclosed to SR Instruments Inc s satisfaction to be defective The provisions of this warranty clause are in lieu of all other warranties expressed or implied and of all other obligations or liabilities on SR Instruments Inc s par
18. strumentation storage and transport conditions should not vary outside the following conditions Relative Humidity 0 to 85 Ambient Temperature 14 F to 122 F 10 C to 50 C TRANSPORTATION To transport the SR555i lower the Height Bar if included tilt the scale back and wheel to the new location Lower the platform back down to the floor being careful not to shock the scale SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i 130314 Page 9 of 20 SPECIFICATIONS MAXIMUM WEIGHT CAPACITY 1000 Ib or 454 kg PLATFORM SIZE 15 3 4inx 18 1 2 in 40 cm x 47 cm DISPLAY TYPE 16 Character Dot Matrix LCD DISPLAY RESOLUTION 0 1 1b 0 1 kg 0 1 1 digit of displayed resolution for calibrated range ACCURACY AUTO ZERO One button operation AUTO POWER DOWN Approximately 30 seconds adjustable to 300 seconds ENTER Stores displayed reading in memory RECALL Recalls last stored stable weight height and BMI AVERAGING Automatic digital filter Six 6 C cell batteries POWER ONE DERE Low battery indicator on Display CALIBRATION Calibration is traceable to NIST standards Normal operating conditions for this product OPERATING CONDITIONS Ambient Temperature Range 68 F
19. t Display will scroll thru WT HT and BMI stored values in approximately two second intervals m ENTER Press to save height data and display BMI calculation Stable weight height and BMI values are stored in memory until next stable weight is stored or until system is zeroed BMI Press to calculate the BMI When the BMP is pressed the default starting value HT BMI 65 in or HT 165 cm is displayed If there is no stored stable weight the display will indicate NO WEIGHT DATA and then go back to the weigh screen WT 0 0 Lb Continued next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _ 130314 Page 11 of 20 BUTTON FUNCTIONS cont d MENU Press Menu to edit setup Setting the UNITS Use UP or DOWN arrow buttons to select Lb or Kg Press ENTER to save changes Setting ON TIME Use UP or DOWN arrow buttons to adjust the ON TIME The ON TIME may be set from 30 to 300 seconds in 30 second increments Press ENTER to save changes Setting TIME and DATE Use the UP arrow button to select digit To change digit use the DOWN arrow button Press ENTER to save changes NOTE When selected the year position defaults to 00 Configuring sc
20. t and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event shall SR Instruments Inc be liable for any subsequent or special damages Any misuse improper installation or tampering shall void this warranty DAMAGED SHIPMENTS Title passes to purchaser upon delivery to Transportation Company Any claims for shortage or damage should be filed with the delivery carrier by purchaser RETURN POLICY All products being returned to SR Instruments Inc require a Return Goods Authorization number RGA To receive an RGA call our Technical Service Team at 716 693 5977 or toll free 1n the USA and Canada at 800 654 6360 When inquiry is made please supply model and serial numbers purchase order if the scale was bought on contract and reason for return Generally deleted damaged and outdated merchandise will not be accepted for credit A minimum restocking charge of 15 will be assessed on return of current merchandise All returns are to be shipped FREIGHT PREPAID to SR Instruments Inc 600 Young Street Tonawanda NY 14150 RESTOCKING FEE e 15 fee for any scale that has been opened and used e 10 fee for any scale returned that has been ordered incorrectly or refused delivery with no model change e 5 fee if an error in ordering has been made and a different model exchanged e No fees will be charged if the scale is r
21. t 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i 130314 Page 7 of 20 ASSEMBLY cont d STEP 2 Apply a small amount of Loctite to the two small screws and attached the Printer Mounting Bracket to the Printer Mounting Collar Figure 6 STEP 3 Attach the Printer to the Printer Mounting Bracket STEP 4 After the Display Unit 1 1s installed refer to page 4 plug the Printer Cable 10 into the Printer and into the connector on the bottom of the Display Unit tighten Printer Cable screws REPLACEMENT PARTS and ACCESSORIES SYSTEM DESCRIPTION and INTENDED USE SYSTEM DESCRIPTION The SR555i Stand On Scale System employs the latest in microprocessor and load cell technology to provide accurate and repeatable weight data Four 4 identically matched transducers are strategically placed to ensure an accurate representation of the patient s weight The low power microprocessor circuitry allows the SR555i to derive its power from six 6 common C cell batteries that will provide up to 10 000 weight readings before needing replacement This eliminates the need for an external battery charger or the danger of an AC power supply cord on a portable scale The patient s weight is displayed on a 16 character dot matrix LCD The weight data may be viewed in either pounds or kilograms with a displayed resolution of 0 1 for each Continued next page SR Instr
22. to 85 F 20 C to 30 C Relative Humidity Range 0 85 Avoid exposure to high pressure water or steam Storage and transportation conditions should not vary TRANSPORTATION and outside the following conditions Relative Humidity STORAGE 0 to 85 Ambient Temperature 14 F to 122 F 10 C to 50 C Remove batteries if storing longer than three 3 months SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _ 130314 Page 10 of 20 BUTTON FUNCTIONS Figure 7 Button Display ZERO WEIGH Press and hold to zero The display will read WT 0 0 Lb This is used to zero the system before placing the patient on the scale system This action also resets previously stored weight height and BMI values to zero Ensure that nothing is in contact with the weighing surface during this procedure Press to weigh Weight stable indicator flashes then remains solid when stable Auto stores stable weight in memory LE SEND PRINTER EHR Press to send stored values to EHR or to printer Output values include time date weight height and BMI Also indicated on display when paper is out PAPER OUT and when door is open PAPER DOOR OPEN bal RECALL Press to recall the last stable weigh
23. uments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SR Instruments Inc Model SR555i Stand On Scale Operating and Service Manual S N 1000 Part No MAN555i _130314 Page 8 of 20 SYSTEM DESCRIPTION and INTENDED USE cont d INTENDED USE The SR555i Stand On Scale System is specifically WARNING designed for use as a stand on scale for weighing ambulatory patients Optional equipment includes a DO NOT EXCEED Handrail Set Height Bar and Printer SR555i Stand MAXIMUM WEIGHT LIMIT OF On Scale System is a preferred means of gathering 1000 LB 454 KG patient weight data of ambulatory patients weighing up to 1000 pounds or 454 kilograms MAINTENANCE and CLEANING SR555i Stand On Scale System is made of a powder coated aluminum casting with a stainless steel riser post Exercise caution when cleaning the display window as it is made of clear polyester and can be scratched by abrasive cleaners Mild soap and water is recommended for general cleaning and disinfecting WARNING DO NOT use pressurized water or steam The scale system contains microprocessor circuitry and strain gauge sensors that may be adversely affected by exposure to such an environment STORAGE and TRANSPORTATION STORAGE If storing this equipment for periods longer than three 3 months remove the batteries To maintain proper operation of this in

Download Pdf Manuals

image

Related Search

Related Contents

千曲市一般廃棄物処理基本計画(970KBytes)  JBL CONTROL® SERIES All-Weather 2-Way, Dual 4" Bookshelf/Wall-Mount/Corner-Mount Speaker  CARDIOGIMA 1M  LaCie Two Big with PCI-E Card 1TB  Dell OpenManage Server Administrator Version 7.4 User's Manual  End User Guide - Systems Made Simple  CATALOGO 2009  User's Manual  AVR-1612  MANUAL DE USUARIO Bienvenido  