Service Manual – G4 Gem Single Head Brewer
Contents
1. VOLTAGE 120V 220V WATTAGE SEE TABLE AMPERAGE SEE TABLE HERTZ 50 60 HZ WIRES 2W 3W G PHASE 1 PHASE USE 187 TERMINAL LUG LADDER DIAGRAM PART NUMBER LD GTPS64 63 REVISION J Cleaning the Coffee Brewer Regular cleaning and preventive maintenance is essential in keeping your coffee brewer looking and working like new IMPORTANT aS x CAUTION Do not use cleansers bleach liquids powders any other substance containing chlorine These products promote corrosion and will pit the stainless steel USE OF THESE PRODUCTS WILL VOID THE WARRANT Y Wipe exterior surfaces with a moist cloth removing spills and debris Slide the brewcone out and clean it Clean the sprayhead area with a moist clean cloth Rinse and dry the brewcone Drain drip tray of coffee Wash out the drip tray Dry the tray Rub a stainless steel polish on the outside surfaces to protect the brewer Cleaning the Satellite Server To clean the Satellite components prepare a mild solution of detergent and warm water e Jp DO NOT immerse the Satellite in water or any other liquid 9 10 Thoroughly rinse out the Satellite with clear warm Remove lid from Satellite Clean the lid at the funnel area with a spiral brush and detergent solution Rinse the lid removing all traces of cleaning solution Unscrew the handle bonnet assembly and remove it from the dispensing faucet Pull t
2. Prev Maint Enter 1 2 3 4 to access the Main Menu n MODEL SELECT Thermopro Gold Cup i Omega H y mi Thermopro 1 Gal SETTINGS SUMMARY One Batch E P Twin Two Batch Three Batch One Batch Two Batch Three Batch One Batch One Batch Twin Two Batch Three Batch One Batch Twin Two Batch Menu Features RECIPES FUNCTION TO SET SETTING RANGE FACTORY SET DEFAULT NOTES COMMENTS Global Recipes Gourmet STD Light Roast Dark Roast High Yield Filter Pack Decaf Gourmet STD Home CONTROL SETTINGS FUNCTION TO SET SETTING RANGE FACTORY SET DEFAULT NOTES COMMENTS Temperature Settings Warmer Settings Increments Minimum Brew Temp 195 F D LLL Disabled 1 Hr 12 Hr 1 Hr Increments 1 Hr 12 Hr 1 Hr Increments OFF HIGH lt MED gt LOW Disabled on GEMT GEMS Note This function is only visible on Gemini Units 10 Hr on GEMTIF GEMSIF gt emini Units MED During Brewing Quality Timer Audible alarm when time is expired Only shows available Disabled on GEMT GEMS TP2T TP2S OMG TPC2T TPC2S gt when a machine has Warmer lt 120min on GEMTIF GEMSIF gt Elements Also this function is visible when Gemini models are selected Disabled 20min 240min 10 Minute Increments Energy Save Mode Activates after
3. 4 Hours of Inactivity No Change Tank temperature is maintained at 9 the temp setpoint default No Change Tank is turned off Tank temperature maintained at 140F Turn Tank Heater Off Reduce tank temp to 140 F Sounds Beeper On Off Turns Board sounds Off or On Diagnostics Auto Test Runs Diagnostic Tests Display Settings Hide Models GEMT GEMS TP2T TP2S OMGT OMGS Quality Timer Hide Show Displays Quality Timer Show Models GEMTIF GEMSIF Rinse Server Hide Show Show Displays Rinse Server Message Prev Maintenance Off 1000 to 20000 Gallons 1000 Increments Maintenance Interval Service Telephone Number Brew Counter Resettable Resettable For maintenance purpose Resettable Passwords Programming Reprogrammable allows access to programming screens Reprogrammable allows access to brewing screens Brew Enabled Disabled Master Reset Select to Reset to Restore Factory Reset Are you sure Yes No Defaults Regional Settings SI US Select to go to Home Page Menu Features FUNCTION TO SET SETTING RANGE FACTORY SET DEFAULT NOTES COMMENTS LARGE BREW 2000z 80z using a Amber 5 Sprayhead Brew by OFF 30sec to Volume 19Min 59sec When this is Chosen COLD BREW LOCK set to 5 F Pulse Brew On Off Function Disabled Brew by 0 to 19Min 59sec Time 1min 01secs increments When this is Chosen COLD BREW LOCK set to 5 F Pulse Brew Di
4. KIT TANK OVERFLOW ELBOW FITTING KIT LIQUID LEVEL PROBE W HEX FITTING O RING amp NUT KIT STRAIGHT PLASTIC FITTING amp BUSHING KIT TANK INLET FITTING TANK COMPLETE GEMSS DV W ULTEM FITINGS TANK COMPLETE GEMSS W ULTEM FITTINGS KIT ELEMENT HEATING 1 6KW120V W JAM NUT amp SILICONE WASHERS SENSOR TEMPERATURE TANK THERMOSTAT HI LIMIT HEATER DPST 277V 40A TUBE 5 16 ID 1 8W SILICONE TUBE SILICONE 01 2 ID x 23 4 OD x 1 8 WALL COMPOUND SILICONE 5 OZ TUBE 1 GALLON SATELLITE SERVER RECOMMENDED PARTS TO STOCK Electrical Schematic GAGEMS 10 2 USE THIS DIAGRAM FOR ALL OTHER MODELS WITH ADDED PREFIXLETTERS AND OR SUFFIX NUMBERS ON THEIR PART NUMBERS HAVINC THE SAME ELECTRICAL RATINGS 1 NOTES UNLESS OTHERWISE SPECIFIED POWER BLOCK 57 65A 300 450V TRANSFORMER WIRE HOOKUPS ol 3l lo B Slol gt m alg lok GRN s 52 0 0 N STP BRN UNIVERSAL TOUCH SCREEN 12Vac BLK THERMOSTAT MAN RESET DPST SSR 1 HEATING ELEMENTS 40A 277V 40A 600V 2X 2 0KW 220V BLU 12GA BLK 12GA _ BLK 12GA BLK 12GA RED 12GA DPST TOGGLE SWITCH 125 250VAC 25A GRN 12GA RED 12GA RED 12GA CHASSIS GROUND STP GRY ALTERNATE 14 PIN CONNECTOR 20 PIN CONNECTOR SENSOR 2 0 TN HEATING gt TANK INLET VALVE 5 GPM 12W 120V BREW VALVE RIGHT UPM GROUND 8 PIN CONNECT
5. installed All in warranty service calls must have prior authorization For Authorization call the Technical Support Department at 1 800 995 0417 Effective date of this policy is April 1 2003 Additional conditions may apply Go to www wilburcurtis com to view the full product warranty information CONDITIONS amp EXCEPTIONS The warranty covers original equipment at time of purchase only The Wilbur Curtis Company Inc assumes no responsibility for substitute replace ment parts installed on Curtis equipment that have not been purchased from the Wilbur Curtis Company Inc The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met The warranty does not cover and is void under the following circumstances 1 Improper operation of equipment The equipment must be used for its designed and intended purpose and function 2 Improper installation of equipment This equipment must be installed by a professional technician and must comply with all local electrical mechanical and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of
6. secure surface 2 Connect the water line to the water inlet fitting on the rear of the unit Water volume flow to the machine IMPORTANT Equipment should be consistent Use tubing sized sufficiently to provide a minimum flow rate of one gallon per minute pret to be installed to comply with applicable govern NOTE A water filtration system must be used to help maintain trouble free operation Air must be uda s oe purged from the cartridge prior to connection to equipment In areas with extremely hard water we highly recommend the use of a Curtis approved water filter For our full line of filters please log on to www wilburcurtis com t thi to hot nhi Pili piss 1 A quick disconnect or additional coiled tubing at least 2x the depth of the unit is required so nabrated for hot water that the unit can be moved for cleaning 2 This unit must be installed with adequate backflow protection to comply with applicable federal state and local codes 3 Water pipe connections and fixtures directly connected to a portable water supply shall be sized installed and maintained in accordance with federal state and local codes e EN CAUTION DONOI NSF International requires the following water connection IMPORTANT 3 Connect the unit to an electrical outlet with appropriate amperage rating see serial tag on machine 4 Once power has been supplied to the unit flip the toggle switch to the ON position located on
7. the rear of ISO 9001 2008 REGISTERED the unit the water tank will begin to fill When the water level in the tank reaches the probe the heating element s will turn on WILBUR CURTIS CO INC 5 Water in the heating tank will require approximately a half hour before reaching operating temperature 6913 West Acco Street factory setting of 200 F Where applicable turn on the Universal Control Module UCM When the unit Montebello CA 90640 5403 reaches operating temperature it will display READY TO BREW For the latest information go to www wilburcurtis com Tel 800 421 6150 For the latest specifications and information go to www wilburcurtis com Fax 323 837 2410 1 QUICK START Your Curtis G4 Gold Cup Series is Factory Pre Set for Optimum Performance After connection to water and power turn on the brewer at the rear toggle switch You will hear a beep and the status lights will come on for a moment The screen will display Next is displayed Water will fill the tank 2 3 minutes depending on water flow rate When the proper level is reached will appear on the screen It takes approximately 30 minutes to reach the set point temperature Control will display when temperature reaches the set point The unit is now ready to brew COFFEE BREWING INSTRUCTIONS 1 Brewer should be ON Confirm at the rear toggle switch The LCD screen should read Ready to Brew 2 Place an empty satellite server on the warmer deck under t
8. EFIX LETTERS AND OR SUFFIX NUMBERS ON THEIR PART NUMBERS HAVING THE SAME ELECTRICAL RATINCS 1 ALL WIRES SHALL BE 18AWG UNLESS NOTED NOTES UNLESS OTHERWISE SPECIFIED 14 120Vac Logic Common WHT Data Communication First RED WIRE SHIELDED CABLE BLK TRANSFORMER POWER DUAL SECONDARY 120 240 12V 4 8VA 14 PIN CONNECTOR 20 CONNECTOR WHT 2 0 GPM 10W 120V INLET VALVE 5 GPM 12W 120V UPM GROUND BREW VALVE RIGHT 5 GPM 12W 120V STP VIO BYPASS VALVE RIGHT UNIVERSAL POWER MODULE UPM 120Vac 5WVac 100W 120V v BLK z BLU 1 BLUE BU O 2 1 GRY p z GRINDER INTERLOCK Element Rating W 1150 1600 1150 1600 of Conductor Elements Wires Voltage V 120 92 110 110 20 95 2100 120 92 110 120 270 10 2400 110 220 127 3300 120 240 15 3600 110 200 107 2350 120 10 1200 120 270 102 2450 120 270 138 3300 120 125 1500 110 200 132 2900 64 1552 120 125 1500 120 240 129 3100 120 138 1650 120 240 121 2900 50 60 50 60 G4 TP2S52 G4 TPC2S52 50 60 G4 TP2S63 G4 TPC2S63 50 60 50 60 1150 G4 TP1S63 50 60 1600 2X 1 6KW 120V BREW CONE LOCK RIGHT HEATING ELEMENTS
9. IT WARMER ELEMENT 100W 120V WARMER ASSY COMPLETE 100W 220V RECOMMENDED PARTS TO STOCK Illustrated Parts 22 23 24 ITEM NO 21A PART NO WC 10001 WC 10015 WC 37122 WC 854 WC 2977 101 WC 43089 WC 589 101 WC 589 102 WC 442 WC 446 WC 844 101 WC 844 102 WC 10000 WC 4212 02 WC 29050 2 lt y A O 64 DESCRIPTION UNIVERSAL POWER MODULE G4 UNIVERSAL POWER MODULE UPM G4 220VAC KIT DUMP VALVE RIGHT VALVE BREW DUMP RIGHT 240V 12W GEM12D TP TPC FITTING SPRAYHEAD ULTEM GASKET 1 00 OD x 625 ID x 030 THK RED SILICONE 40 SHORE TRANSFORMER 120 230V 24V 4 8A WILEADS amp MOLEX CONNECTOR TRANSFORMER 240VAC 24V 4 8VA WILEADS amp MOLEX CONNECTOR SOLENOID LOCK BREWCONE RIGHT 120VAC SOLENOID LOCK BREW CONE RIGHT 220V THERMOPRO GEMTS VALVE BYPASS 120V 14W NON ADJUSTABLE W RESTRICTOR WC 2945 VALVE BY PASS 220V NON ADJUSTABLE W RESTRICTOR WC 2945 CONTROL MODULE UCM TOUCH SCREEN G4 NUT 5 8 18 JAM PLASTIC ULTEM SPRAYHEAD ASSY AFS AMBER RECOMMENDED PARTS TO STOCK 11 Illustrated Parts Heating Tank 12 ITEM NO 24 25 26 21 28 29 30 30 31 32 33 34 35 36 of PART NO WC 5853 102 WC 43062 WC 37266 WC 5502 01 WC 37357 WC 37365 WC 62034 WC 62035 WC 904 04 WC 1438 101 WC 522 WC 5310 WC 5350 WC 5231 GEM 3 DESCRIPTION COVER TOP HEATING TANK GASKET TANK LID
10. OR Vdd 5Vdc E BLK Vss Logic Common Data Communication First V RED STP VIO 9 GPM 1 5 SHIELDED CABLE BYPASS VALVE RIGHT BLU 1 BLUE 2 GRY 3 GRINDER INTERLOCK ELECTRICAL RATING TABLE USE 187 d TERMINAL LUG HEATING TOTAL TOTAL ELEMENTS POWER CURRENT warts AMPERES 5 CONNECTOR WARMER BLK 1 Pow dd UNIVERSAL POWER MODULE 120Vac 5WVac WHT 22AWG USB 5Vdc 6 CONNECTOR SSR PIN ASSIGNMENTS TITLE LADDER DIAGRAM ALL WIRES SHALL BE 18AWG UNLESS NOTED Lemssio an pete o 195 BET NUMBER REVISION mmo e e 195 D GTPSG4 10 19 Electrical Schematic G4GEMS 63 WHT 12GA WHT 12GA On CURRENT BLK 12GA SENSOR BLU 12GA BLK 12GA KS PINA ae A WHT 12GA WHT 18GA x IN m RED 12GA 120 208 240Vac 1PH 88 5224 RED 12GA 2W 3W G 50 60 Hz TOGGLE SWITCH GRN 12GA THERMOSTAT MAN RESET 125 250VAC 25A POWER BLOCK mU RED 12GA 57 65A 300 450V CHASSIS GROUND STP GRY ALTERNATE TRANSFORMER WIRE HOOKUPS Vdd 5Vdc 8 PIN CONNECTOR UNIVERSAL TOUCH SCREEN 12Vac 5 CONNECTOR F 9 8 gt 2 o gt 77 1 5 12GA WHITE WIRE IS ONLY USED WHEN UNIT IS TO BE WIRED IN THE 120Vac CONFIGURATION 2 USE THIS DIAGRAM FOR ALL OTHER MODELS WITH ADDED PR
11. WILBUR CURTIS COMPANY NC Service Manual G4 Gem Single Head Brewer Important Safeguards Symbols This equipment is designed for commercial use Any servicing other than cleaning and routine maintenance should be performed by an authorized Wilbur Curtis Company Service Technician DO NOT immerse the unit in water or any other liquid Toreduce the risk of fire or electric shock DO NOT open service panels There are no user serviceable parts inside Keep hands and other items away from hot areas of the unit during operation Never clean with scouring powders or harsh chemicals Symbols WARNINGS To help avoid personal injury Important Notes Cautions from the factory ist Sanitation Requirements Mode 15 Curtis Generation 4 Unit is Factory Pre Set and Ready to Go Right from the Box e G4GEMS Following are the Factory Settings for your G4 Coffee Brewing System Brew Temperature 200 F Water Bypass On for LARGE amp MEDIUM Brew Only Brew Volume Set to Vessel Requirement System Requirements es CAUTION Please use Water Source 20 90 PSI Minimum Flow Rate of 1 GPM IMPORTANT this setup procedure Electrical See attached schematic for standard model or visit www wilburcurtis com for your model before attempting to use this brewer Failure to follow the instructions can result in injury or the SETUP STEPS voiding of the warranty 1 The unit should be level left to right front to back on a
12. he brewcone and touch the warmer icon to Preheat the satellite The coffee vessel is heavy when full Take precautions to avoid dropping when moving WARNING AVOID SCALDING REMOVE THE BREW CONE CAREFULLY The brew cone contains hot coffee grounds CAUTION 3 Place a new paper filter into the brew 4 Fill the brew cone with the proper 5 Transfer the filled brew cone to the cone amount of ground coffee brewer ENTER BREW CODE Ready to k 6 Start the brew cycle by hold your finger requires a code to be entered before a brew During the brew cycle an animated 172 on the desired brew icon As soon as will start The default is OFF gallon satellite server icon will appear on the you hear the click of the brew valve th AUTION When enabl ed as soon as you screen and a brew timer will count down the brew cycle has started and you can lift e your ios enter the brew code a brew cycle starts time remaining on the brew cycle Refer to page 8 for information about setting Brew Code You may find that when a brew the Brew Code button is pressed a key pad appears on the screen This is a brew lock out feature that 2 Touch Screen Control Module The touch screen turns on when power is available to the controller The screen will contain standard control feature such as symbols and but tons Pressing these elements with your finger tip will activate the programming functions The default screen as wel
13. he data copied from the first G4 brewer will automatically down load overwriting all the settings that were on the second brewer The red LED on the UCM will indicate that the download is in process This will only take a second Once the download is complete the UCM will reboot in order for the changes to take effect Remove the flash drive The download is complete The data on the flash drive can be downloaded into as many G4 brewers as needed This screen will be presented whenever the USB flash is inserted precem The UCM will always create a backup on the USB flash drive toUSB fromusg o action before downloading settings recipes or screensaver Settinas recipes Present ipd P Case 1 Screensaver oettings recipes file present screensaver not present User EE has selected Download from USB for settings recipes file FILE TRANSFER Upload Download to USB from USB Case 2 Settings recipes As above but user has selected Upload to USB for settings recipes file With this action the overwrite warning appears No action Brew Access Code KT zn i CANCEL 22 Tap Curtis Logo 5 Times to Enter Programming Mode ENTER ACCESS CODE 1234 Enter 1 2 3 4 to access the Main Menu O CONTROL SETTINGS BREW SETTINGS Ja B SETTINGS SUMMARY EXIT RECIPES MODEL SELECT Temp Settings The Password
14. he silicone seat cup from faucet stem and inspect it for wear cracks or hardening Replace the seat cup if necessary Clean all parts Thoroughly rinse with clear warm water Dry and assemble the handle bonnet parts Hand tighten the assembly onto the faucet Remove the gauge glass tube by unscrewing the gauge glass cap Clean the gauge glass tube and the two washers with a gauge brush and detergent solution Rinse with clear water Dry the parts and assemble them onto the Satellite Clean inside of the Satellite Remove coffee resi due with the detergent solution water 15 Liquid Level Probe Cleaning intervals for the probe are to be determined by the user or the service tech based on water conditions The use of water filters or the type of water filter that is being used can impact the service interval Intervals can be from one month to several years however replacing rather than cleaning the probe is preferable WARNING Disconnect electrical power before removing access panels CAUTION This procedure involves working with hot water and hot surfaces 1 Unplug the power cord and shut off the water line 6 If a white residue is still visible on the probe remove the probe and Remove the top cover of the coffee brewer Locate the heating tank Open the hot water faucet and drain the tank to a level about 3 below Allow some time for the heating tank and liquid level probe to cool Clean the
15. head On Off SMALL BREW Off using a Amber AFS Sprayhead ee qc NN Off 10 Seconds 15min O gt System Fault Messages WARNING MESSAGES ALLOWS BREWING MESSAGE DISPLAY WARNING DESCRIPTION CAUSE Brew count Gallons Since Reset exceeds programmed Preventative Maintenance period Maintenance Required Maintenance Required If the Inlet valve remains on longer than XX Seconds during the brew cycle only and repeats TWICE during that brew cycle It shall clear upon the next brew and if the same low flow exists again it will re appear XX Alpha 20 secs Gem TP Twin 40 secs Gem TP Single 30 secs Low Water Flow Warning Low Water Flow ERROR MESSAGES STOPS BREWING MESSAGE DISPLAY ERROR DESCRIPTION CAUSE The fill solenoid has either run for more than 10 minutes on the initial tank fill or 120 Seconds on Large Brewers and 30 Seconds on CGC Brewer in normal operation Water Level Error Fill run error Overflow Break in the temperature thermistor circuit or short Sensor Error Open Sensor Curcult The sensor is reading that temperature in the Over Temp Error Excess Temperature heating tank has risen above 210 F or sensor has shorted to ground Internal Error 1 UPM UCM Communication Break in the UPM UCM Communication circuit USB Easy Programming There are two methods that can be used to change the default settings on G4 brewers They can be programmed at the brewer by the touch screen universa
16. l as some added control buttons are shown in the illustration below STATUS LIGHTS WARMERS The warmer temperature can be adjusted by using N the G4 touch screen There are three temperature selections plus off Each time the warmer icon is pressed the tempera ture increases to the next setting EIS LOW MEDIUM HIGH OFF BREW BUTTONS CURTIS LOGO TO ENTER PROGRAMMING Tap Curtis logo 5 times to bring up the ACCESS CODE screen CONTROL SYMBOLS All of these symbols may not be visible at one time w P l J r w RETURN TO HOME UNDO SAVE SCROLL ENTER PROGRAMMING ENTER ACCESS CODE 2 MAIN MENU Recipes Control Settings Brew Settings Model Select Settings T ACCESS CODE screen Default is 1 2 3 4 MAIN MENU screen contains six control icons Once the code is entered press OK The RECIPES CONTROL SETTINGS BREW SETTINGS Main Menu screen will appear MODEL SELECT SETTINGS SUMMARY and EXIT The access code can be reset in Control Settings PASSWORDS PROGRAMMING Continued Menu Tree This chart explains how to enter the program mode and menu selections available from the MAIN MENU Ready to brew CANCEL Tap Curtis Logo 5 Times to Enter Programming Mode L CONTROL SETTINGS BREW SETTINGS RECIPES Select Button EIN
17. l control module UCM or the settings can be changed using the USB Universal Serial Bus data port on the side of the brewer Using the USB connection and a flash memory data storage device will easily reprogram the settings simply by copying data The flash drive can upload or download the entire setting from one G4 brewer into another G4 brewer This eliminates the need to walk through the usual steps in reprogramming that would be required when you use the touch screen to make a change This is an advantage for a service technician when standardizing the program settings on multiple C4 brewers Use a USB drive with USB 2 0 support and a type A USB connection Storage capacity should be 2 GB minimum IMPORTANT The flash drive must be completely blank Before starting please erase any files that may be in the USB drive SOFTWARE INFORMATION TRANSFER UPLOAD TO USB 1 Make sure the brewer is on Determine that the G4 brewer you wish to copy is properly programmed for your desired settings 2 Connect an empty flash drive into the USB port on the brewer The UCM on the brewer will upload all of the particular setup data onto the flash drive The yellow LED on top of the touch screen will light indicating that data is transferring This will only take a second to complete DOWNLOAD TO BREWER 1 Selectthe brewer you wish to make the program changes on The brewer should be on 2 Plugthe loaded flash drive into the USB port on the brewer T
18. sabled 20 secs On 20 secs Off Pre Infusion 30 secs 30 secs Disabled MEDIUM BREW 13207 4oz using a Amber AFS Sprayhead To Set Press Brew to start Press Brew to stop SMALL BREW 640z 4oz using a Amber AFS Sprayhead LARGE BREW 5min 25secs using a Amber AFS Sprayhead Note These are the default times for a Amber AFS MEDIUM BREW 3min 32secs using a Amber AFS Sprayhead Sprayhead SMALL BREW 1min 52secs using a Amber AFS Sprayhead When this is Chosen COLD BREW LOCK set to 5 F Pulse Brew On Off Function Disabled 60 secs On 60 secs Off When this is Chosen COLD BREW LOCK set to 5 F Pulse Brew On Off Function Disabled 10 seconds ON 4 Times 10 seconds OFF 4 Times then ON Till End of Brew Cycle 1 Minute ON 10 seconds OFF 4 Times 10 seconds 4 Times Till end of Brew Cycle C 25 seconds 5 Times 20 seconds OFF 5 Times then C C ON Till End of Brew Cycle Pulse Brew On Off D Manual Program PULSE COUNT 1 to 20 pulses ON TIME 5 150 seconds OFF TIME 5 150 seconds 5 second increments E Manual Program PULSE COUNT 1 to 12 pulses ON TIME 0 150 seconds OFF TIME 1 150 seconds 1 second increments LARGE BREW 3575 using a Amber AFS Sprayhead By Pass Off 575 5075 in 1 MEDIUM BREW 107 using a Amber AFS Sprayhead Note These are the default times for a Amber AFS increments Spray
19. screen will Quality Timer display two selections p Programming Password or Energy Saving i I Sou zu Brew Password To set up or change the brew Disabled assword press the Brew Password Edit Enabled Enable button then the Edit button The Brew Diagnostics 2 Password screen will Display Settings appeal Prev Maint When resetting a BREW PASSWORD password press clear then select a new password numbers only If enabling the brew password select a password code Press the enter icon to set the new password Press home icon to return to main menu and exit Brew Counter Passwords Master Reset Regional Settings Illustrated Parts Main View 10 ITEM NO 1 2 3 4 5 6 7 8 WC 58117 WC 8559 WC 61396 WC 3417 WC 1809 WC 39448 WC 1501 WC 847 WC 883 WC 103 WC 13463 WC 14045 101 WC 3528 WC 5428 WC 37102 WC 975 DESCRIPTION COVER TOP WRAP RELAY SOLID STATE 40A W INTEGRATED HEAT SINK COVER CENTER FRONT BREW CONE ASSY W SPLASH POCKET BROWN STYLIZED GEM HOT COFFEE FAUCET PS HPS SERIES HOT WTR 1 2 20 UNF AP ALP LABEL BOTTOM WRAP FUSE HOLDER ASSY w 5A FUSE VALVE INLET 2 GPM 120V 10W VALVE INLET 2 GPM 240V 10W SWITCH TOGGLE NON LIT DPST 25A 125 250VAC RESISTIVE HARNESS ASSY COMPLETE G4TP2S10 G4TPC25S10 CURRENT SENSOR ASSY G4 LEG 4 ADJUSTABLE 3 8 16 THRD STYLIZED DECK WARMER W A K
20. the equipment owner The owner is responsible for proper cleaning and regular maintenance of this equipment 6 Damagedin transit Equipment damaged in transit is the responsibility of the freight company and a claim should be made with the car rier 7 Abuse or neglect including failure to periodically clean or remove lime accumulations Manufacturer is not responsible for variation in equipment operation due to excessive lime or local water conditions The equipment must be maintained according to the manufacturer s recommendations 8 Replacement of items subject to normal use and wear This shall include but is not limited to light bulbs shear disks 0 rings gaskets silicone tube canister assemblies whipper chambers and plates mixing bowls agitation assemblies and whipper propellers 9 Repairs and or Replacements are subject to our decision that the workmanship or parts were faulty and the defects showed up under normal use All labor shall be performed during regular working hours Overtime charges are the responsibility of the owner Charges incurred by delays waiting time or operating restrictions that hinder the service technician s ability to perform service is the responsibility of the owner of the equipment This includes institutional and correctional facilities The Wilbur Curtis Company will allow up to 100 miles round trip per in warranty service call RETURN MERCHANDISE AUTHORIZATION All claims under this warranty m
21. tip of the probe using a Scotch Brite scuff pad and remove the top cover the tip of the probe down before proceeding soak it in vinegar or a scale removing chemical Repeat this step until the probe is clean Rough In Drawing Cf CS NC S Cf N 16 11 75 29 8 cm 7 00 9 75 17 8 cm 14 6 cm 4 00 10 2 cm Page Intentionally Left Blank Product Warranty Information The Wilbur Curtis Company certifies that its products are free from defects in material and workmanship under normal use The following limited warranties and conditions apply 3 Years Parts and Labor from Original Date of Purchase on digital control boards 2 Years Parts from Original Date of Purchase on all other electrical components fittings and tubing 1 Year Labor from Original Date of Purchase on all electrical components fittings and tubing Additionally the Wilbur Curtis Company warrants its Grinding Burrs for Forty 40 months from date of purchase or 40 000 pounds of coffee whichever comes first Stainless Steel components are warranted for two 2 years from date of purchase against leaking or pitting and replace ment parts are warranted for ninety 90 days from date of purchase or for the remainder of the limited warranty period of the equipment in which the component is
22. ust be submitted to the Wilbur Curtis Company Technical Support Department prior to performing any repair work or return of this equipment to the factory All returned equipment must be repackaged properly in the original carton No units will be accepted if they are damaged in transit due to improper packaging NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION RMA RMA NUMBER MUST BE MARKED ON THE CARTON OR SHIPPING LABEL All in warranty service calls must be performed by an authorized service agent Call the Wilbur Curtis Technical Sup port Department to find an agent near you 15688 4 8 14 13 2 rev E WILBUR CURTIS CO INC p 6913 Acco St Montebello CA 90640 5403 USA Phone 800 421 6150 Fax 323 837 2410 Technical Support Phone 800 995 0417 M F 5 30A 4 00P PST E Mail techsupport wilburcurtis com Web Site www wilburcurtis com 4 2014 F 3842rev E
Download Pdf Manuals
Related Search
Related Contents
SIMOTION P350-3 e pannelli frontali Philips CD Soundmachine 取扱説明書 Catalogo NEO-WIFI SUUNTO SMART SENSOR Adhésion Mode d`emploi Samsung E2100 manual de utilizador 《バージョンアップの方法》 AC-FW0514VP User Manual - Alt Ctrl‧Security Control USB 300 / USB 300C / USB 300U (OEM) USB Gateway for Copyright © All rights reserved.