Home
Christie IMB-S2 CompactFlash Card Replacement
Contents
1. Tap General gt I MB Upgrade Select an upgrade file in the Upgrade Files on Server list Select Full Install to upgrade all files or Select Differences to upgrade the files that are different from the upgrade file or Select Factory Install to upgrade all files to the factory settings Tap Upgrade Tap Yes Restart the Christie MB S2 twice when the software upgrade is complete Activate Marriage You must complete the Marriage wizard to display secure content Marriage permission is required to complete marriage and only Christie accredited technicians are authorized to activate projector marriage 1 Tap Menu gt Service Setup gt IMB Marriage 2 Complete the Marriage wizard 3 Tap Finish Christie MB S2 CompactFlash Card Replacement 020 200249 03 Rev 1 03 2014 CHAISTIE Restore Settings with a Backup File If a back up file is not available you will need to manually re configure these settings Network and storage settings Speaker and audio channel mapping Automation macro definitions Multi projector configuration Scheduled entries For these procedures see the Christie IMB User Manual on the Christie web site L D O a a r Oe Tap Menu gt Christie I MB gt System Tap General gt Backup Restore Tap Browse and browse to the location of the file Select the file Tap Accept Select the backup file in the Restore Files on Server list Tap Restore Tap Yes Upload Licens
2. 5 Remove the card cage faceplate by the handles and set it on a stable surface Replace the CF Card 1 On the underside of the Christie MB S2 pull the CF card retaining clip down and out of the way 2 Pull the CF card A out of the housing and discard it following your local regulations for electronic waste disposal to m r 3 Slide the new CF card into the housing and then push the retaining clip down Reassemble the Projector Push the card cage faceplate into the projector Install the 8 card cage faceplate screws Replace the anti tamper label on the side of the card cage Install the card cage surround og ee Connect the projector to AC power and then turn it on Christie MB S2 CompactFlash Card Replacement 020 200249 03 Rev 1 03 2014 CHAISTIE Upload the Christie IMB Software Upgrade Package Upload and install the latest Christie IMB software so all of the Christie IMB software components are the same version Contact Christie Technical Support to request the latest version of the Christie IMB software l oe E E Insert a USB flash drive with the upgrade package into the USB port on the side of the touch panel controller TPC Tap Menu gt Christie I MB gt System Tap General gt I MB Upgrade Tap Browse and browse to the location of the file Select the file Tap Accept Install the Christie IMB Software Upgrade Package 1 2 3 4 Tap Menu gt Christie I MB gt System
3. CHAISTIE SERVICE BULLETIN Christie IMB S2 CompactFlash Card Replacement Applies to the Following Products Prepared For Internal and External Operators and Service Technicians External Customers Christie Field Application Engineers FAE Christie Service Technicians Christie Personnel e Solaria One e Solaria One e Christie MB S2 This document provides information and procedures for replacing the SanDisk CompactFlash CF card with an Advantech CF card on the Christie IMB S2 The existing SanDisk CF card in the Christie MB S2 can fail when the maximum read modify write cycles are reached A failed CF card can disrupt playback or make the Christie IMB S2 unresponsive The number of replacement CF cards provided by Christie Digital Systems will match the quantity of Christie I MB S2s SanDisk CF card replacement is MANDATORY on all Christie MB S2s manufactured before December 2013 Safety Precautions ELECTRICAL SHOCK HAZARD Always turn off disconnect and disengage all power sources to the projector before servicing Failure to comply results in death or serious injury Only Christie accredited service technicians are permitted to open any enclosure on the projector and only if the AC power has been fully disconnected Failure to comply could result in minor or moderate injury When removing or installing the Christie IMB wear an anti static wrist strap and NOTICE follow anti static protocols Failure to
4. comply could result in equipment or property damage Prerequisites e Christie IMB S2 e Replacement Advantech CompactFlash CF card 003 004700 02 e Replacement anti tamper label Christie Solaria One and Christie Solaria One only Christie MB S2 CompactFlash Card Replacement 1 020 200249 03 Rev 1 03 2014 CHAISTIE Symptoms of CF Card Failure When a CF card fails the Screen Management System SMS becomes unresponsive or fails to start If the SMS fails to start the Alarm and SMS Run LEDs on the Christie IMB S2 faceplate are yellow and all other LEDs are green Occasionally the SMS starts and runs as expected for an extended period When a CF card failure occurs the IMB icon in the touch panel controller TPC task bar appears grey WB Menu gt gt ud i Service NA O 9 4 07 10 01 PM When the CF card fails an error message indicating IMB server connectivity has been lost can appear and playback can stop prematurely Confirm CF Card Failure To confirm a CF card failure the SMS must be running You cannot complete this procedure if the CF card has permanently failed 1 Insert a USB flash drive in the USB port on the side of the touch panel controller TPC 2 Tap Menu gt Christie IMB gt System 3 Tap General gt Settings 4 Tap Run Interrogator 5 Tap Yes The interrogator file is saved as a compressed file named I nterrogator lt numeric string gt Zip The file
5. contains the SMS log file the Security Manager SM log file and configuration information 6 Open the interrogator zip file and review the InterrogatorSM txt file for a CloseClient entry For example Jun 29 14 35 13 s6o_security_manager uucp err sm ERR CloseClient gt SSL_shutdown 0 SSL_get_error 5 ERR_get_error 0 error 00000000 11b5 0 func 0 reason 0 The CloseClient entry indicates a CF card failure Time entries are displayed in Coordinated Universal Time UTC Christie MB S2 CompactFlash Card Replacement 2 020 200249 03 Rev 1 03 2014 CHAISTIE Resolution Use these procedures to remove the SanDisk CompactFlash CF card and replace it with an Advantech CF card Back Up Settings A backup can only be completed when the SMS can be started 1 Tap Menu gt Christie I MB gt System 2 Tap General gt Backup Restore 3 Tap Backup 4 Enter a name for the backup file 5 Tap Enter 6 Tap OK Remove the Christie IMB S2 This procedure describes the removal of a Christie IMB S2 from a Christie Solaria One projector For removal instructions that are specific to your projector model see the projector Service Manual 1 Turn the lamp off and allow it to cool for a minimum of 15 minutes 2 Turn the projector off and disconnect it from AC power 3 Remove the card cage surround Christie MB S2 CompactFlash Card Replacement 3 020 200249 03 Rev 1 03 2014 CHAISTIE
6. e Keys If you purchased licenses to enable additional features you do not need to purchase new licenses However you will need to upload them again when you replace the CF card L 2 3 Tap Menu gt Christie I MB gt System gt Licenses Tap Add Insert a USB flash drive with the Christie IMB license into the USB port on the side of the touch panel controller TPC Select a license file and then tap Accept Technical Support North and South America 1 800 221 8025 or tech support christiedigital com Europe Middle East and Africa 44 0 1189 778111 or techsupport emea christiedigital com Asia Pacific tech asia christiedigital com Christie MB S2 CompactFlash Card Replacement 020 200249 03 Rev 1 03 2014