Home

Bari10A User Manual

image

Contents

1. s Healthcare User Service Manual Joernse Model Bari10A Bariatric Bed To avoid injury read user s manual before using bed on leading bed evolution Joernse Bariatric Beds Bari1OA Model Important Precautions AA Warning Possible Injury Or Death This product is intended for use as an adjustable mattress platform that articulates for resident patient comfort with adjustable height for resident patient and caregiver convenience Use of this product in a manner for which it was not designed could result in unproven or unsafe configuration potentially resulting in injury or death Warning Possible Injury Before adjusting bed ensure that area under and near bed perimeter is free of people and obstructions Failure to do so could result in injury AA Warning Possible Injury Keep bed in lowest position except when providing care bathing clothing changes etc Bed should be at lowest convenient height for entry or exit Failure to do so could result in injury AA Warning Possible Injury Or Death Floor locks increase bed stability and resident patient safety Floor and caster swivel locks must be locked prior to any resident patient transfer or resident patient use of the bed Failure to do so could result in injury or death Warning Possible Injury Or Death Residents patients may become entangled in pendant cord Patients with reduced mental acuity should not be allowed access to pendant
2. Figure 1 Lockout Control 1 Activate Selective Function Lockout on bed Frame to keep resident patient from operating Actuators with Pendant See Selective Function Lockout instructions on Page 8 Warning Possible Injury Or Death Use Selective Function lockout to deactivate bed when resident patient movement or inadvertent activation of bed functions by resident patient or staff member could result in personal injury Figure 2 VA ea ele info joerns com Bed Operation Initial Start Up 1 After positioning bed always lock all casters Bed must reach proper operating temperature before plugging Power Cord into grounded hospital grade receptacle Caution It is critically important to lock all four casters individually to prevent unintended bed movement Resident patient Transfer 1 Lock Casters and make sure Mattress Support Platform is in non extended position narrow Lower Side Rails and lower resident patient in carefully controlled manner onto bed Caution It is critically important to lock all four casters individually to prevent unintended bed movement Emergency Manual Mattress Support Platform Release 1 The quickest way to lower all Mattress Support Platform parts is to power down with Pendant controlled Actuators Note To lower bed in case of power and battery backup failure use Emergency Manual Mattress Support Platform Release to lower Head and Foot Mattress Support Platform
3. or is defective Not plugged in and running on batteries Remove bed from use and contact Joerns Healthcare Technical Support at 800 966 6662 Replace all six batteries Contact Joerns Healthcare Technical Support at 800 966 6662 Reattach cable Refer to Page 13 of this Manual Disengage 5th Wheel While actuating the latch handle try to extend the mattress support platform extension Refer to page 9 of this manual Wider support platform sections may require two hands to apply equal pull force Contact Joerns Healthcare Technical Support at 800 966 6662 Refer to Pendant Control Troubleshooting on page 18 Refer to page 8 of this manual Selective Function Lockout Remove bed from use and contact Joerns Healthcare Technical Support at 800 966 6662 Remove bed from use and contact Joerns Healthcare Technical Support at 800 966 6662 Remove bed from use and contact Joerns Healthcare Technical Support at 800 966 6662 Remove bed from use and contact Joerns Healthcare Technical Support at 800 966 6662 www joerns com info joerns com Joernse Bariatric Beds Bari1 OA Model Appendix A Actuator Wiring Diagram H e j i d 4 DW T Cable 1 Hoad End Hi Lo T Cable 2 Foot End Hi Lo www joerns com info joerns com Joernse Bariatric Beds Bari10A Model Appendix B Scale System Wiring Diagram 7 DESCRIPTION re Membrane Keypad 7 Scale Display Assy Detai
4. Leit Comer Extension Gel DIMENSION Description LAE HEN Pd mr meren PENSION Foot Extension fight Comer Extension left Side Extension 6x6 106 5 D Right Comer Extension Right Side Extension Figure 18 wvwvwv joerns com info joerns com Scale System Bari10A bed is equipped with Scale System fully integrated within Foot Panel Figure 19 Scale System Features Figure 20 1 Resident patient s weight is displayed on a 16 character dot matrix liquid crystal display with LED backlighting 2 Resident patient s weight may be viewed in both pounds and kilograms by pushing Weight Mode button when displayed with resolution of 0 1 Lb Kg 100 grams 3 Monitor resident patients weight relative to zero by using Weight Change Mode button to observe variations in weight 4 Freeze Resume mode button provides customized ability to adjust resident patient s comfort by adding or removing pillow or blanket or ancillary equipment without affecting resident patient s displayed weight Maximum Weight Capacity Do not exceed rated safe working load capacity of bed 1050 pounds Accuracy 0 5 of resident patient weight or 0 5 Ib whichever is greater from 250 to 1050 Ibs while bed is in flat position Auto Power Down APD Scale System will automatically power down in 60 seconds to conserve battery life Averaging Automatic Digital Filter samples weight data to filter motion Power Supply 6 D
5. extends an extra 8 length for taller residents patients e 18 3 4 to 33 3 4 Travel Range e Integrated Scale System for resident patient weight monitoring e Head and Foot End Side Rails Assist Devices e Side Rails on Head and Foot sections fold down for easy resident patient access e Pendant Control for all bed functions with separate Selective Lock Out to override functions e Emergency Manual Release for Mattress Support Platform e Emergency Battery Backup System e Integrated Trapeze Mounts e Quiet DC Motors e Welded Steel Tubular Frame e Pan Style Mattress Support Platform e Wide Stable Base e SoftTone Frame Color e Heavy Duty Casters e CenterLine Caster Locks e Bed Angle Indicators Electrical Specifications Scale System Power 9V DC 6 Alkaline D Cells Actuators Power 115 VAC North American Frequency 60 Hz Current Rating 6 0 Amps Classification Class 1 Type B Mode of Operation 10 Maximum duty cycle Circuit Protection Auto reset current sensors Note Actuators operate on a 24V DC system with an integral battery backup Joerns Bariatric Beds Bari1OA Model Classifications UL 60601 1 CAN CSA C22 2 NO 601 1 IEC 60601 2 38 CAN CSA C22 2 NO 601 2 38 Environmental Conditions Operating Conditions Ambient Temperature 20 C to 30 C Relative Humidity 10 to 95 Non Condensing Atmospheric Pressure 700 hPa to 1060 hPa Protected Against Splashing Water IPX4 Storage and Shipping
6. Conditions Ambient Temperature 30 C to 50 C Relative Relative Humidity 10 to 95 Non Condensing Atmospheric Pressure 500 hPa to 1060 hPa Accessories And Options Joerns Mattresses IV Rod Floor Mat Bed Identification Numbers When ordering parts or when contacting our Customer Care Department please include the bed s model and serial numbers found on the identification label The identification label is located on bed frame under the sleep deck foot section Mechanical Specifications Description Dimensions Overall Bed ee ese Minimum 39 x 90 Maximum 52 x 98 Mattress Support Platform Minimum 36 x 80 Maximum 48 x 88 Bed Frame Weigf1 700 Ibs Maximum Back Section Angle 65 to horizontal Maximum Knee Section Angle 35 to horizontal Maximum Knee to Leg Angle 45 Maximum Height Mattress Support Surface esse 33 3 4 Above Floor Minimum Height Mattress Support Surface 18 3 4 Above Floor Safe Working Load 1050 Ibs www joerns com info joerns com Joernse Bariatric Beds Bari1 OA Model Head Foot Panel Removal Assem D ly 1 Head Foot Panels remove easily Replace by simply lifting straight up or pushing straight down Figure 1 Caution Disconnect Foot Panel Scale System Cable before removing Foot Panel Figure 2 2 Head Foot Panel pins fit tightly in respective frame receptacles This may ca
7. Point WI 54481 P 800 826 0270 F 800 457 8827 wvvw joerns com email info joerns com 2008 Joerns Healthcare Inc Part 6110033 RevF DCO 08 0411 Joerns Healthcare s obligation under this warranty is limited to supplying replacement parts servicing or replacing at its option any product which is found by Joerns Healthcare to be defective Warranty replacement parts are covered by the terms of this warranty until the product s original one year warranty period expires When requested by Joerns Healthcare parts must be returned for inspection at the customer s expense Credit will be issued only after inspection Service Most service requests can be handled by the facility Maintenance Department with assistance from the Joerns Healthcare Product Service Department Most parts requested can be shipped next day air at the customer s expense Should a technician be required one will be provided by Joerns Healthcare at our discretion Only the Joerns Healthcare Product Service Department can dispatch authorized technicians This warranty is extended to the original purchaser of the equipment
8. Unsupervised use of pendant could result in injury or death Warning Possible Injury Or Death Bed safe working load is 1050 pounds This is total weight counting resident patient mattress bedding and any other equipment or persons likely to be on bed Do not exceed 1050 pound safe working load Exceeding the safe working load could result in property damage injury or death Warning Possible Fire Hazard Use nasal mask or bed tent oxygen administering equipment Oxygen tent should not extend below Mattress Support Platform Pendant should not be placed in an oxygen enriched environment such as an oxygen tent Use of electrical circuits in an oxygen enriched environment could result in a fire hazard www joerns com info joerns com A Warning Possible Shock Hazard Unplug power cord from wall outlet before performing any maintenance cleaning or service to the bed Failure to do so could result in injury or death Note In case of unexpected movement unplug bed from any outlet A Warning Possible Shock Hazard Injury may result from improper routing of the power cord Always follow the proper factory installed routing configuration Failure to do so could result in injury or death A Warning Possible Injury Or Death Use a mattress that is properly sized to fit Mattress Support Platform which will remain centered on Mattress Support Platform relative to State and Federal guidelines Length and width should match Ma
9. not attempt to move the bed laterally with the steer mode engaged The steer wheel can not swivel Caution To avoid damage to the siderail mechanisms do not move the bed using the siderails Use the push pull handles integrated to the end panels to move the bed Steer Pedal Operation Figure 11 To engage the steer wheel fully depress the side Steer steer of the pedal identified with a green label and Disengaged Engaged represented by the ENGAGE green arrow To Left Side from foot of bed disengage the steer wheel fully depress the side of the pedal identified with a red label and represented by the DISENGAGE red arrow Vee N steer Steer Engaged Disengaged Right Side from foot of bed Figure 11 www joerns com info joerns com Joernse Bariatric Beds Bari1 OA Model Mattress Support Platform Warning Possible Equipment Damage Prior to Width Extenders use of the MSP Length Extender the Frame Length 1 The four Mattress Support Platform MSP Extender must be fully extended and latched Failure sections each have a 6 Width Extender on to do so will result in scale connector damage both sides of the bed Figure 12 2 Release Width Extender by pulling latch handle along the bottom edge of each MSP section Figure 13 Note Width Extenders lock in either full open or full closed position and should only be used in these positions Side Rails move with the Width Extenders Caution Extend a
10. sections Figure 3 To return Mattress Support Platform to flat position in case of power and battery backup failure rotate Emergency Manual Mattress Support Platform Release Lever Up Hold Emergency Release handle Up until Mattress Support Platform lowers to desired position Release handle if you need to stop descent Joernse Bariatric Beds Bari10A Model Pendant Control Operation 1 Your Bari10A bed comes standard with Pendant Control Figure 4 Resident patient and staff can use the Pendant to adjust all Mattress Support Platform sections to desired positions Pendant has raised push buttons with graphics and may be hooked on rails or panels for convenient resident patient and staff access Figure 4 www joerns com info joerns com Joernse Bariatric Beds Bari1OA Model Selective Function Lockout 1 Selective Function Lockout switch box is located on bed frame Side Rail near Foot Panel Figure 5 Three switches on box allow for certain Pendant functions to lock out separately Figure 6 2 Lockout is intended for use by caregiver when limiting bed positions for specific resident patient care 3 To lock unlock functions rotate switch until it clicks into position Side Rails Assist Devices 1 BarilOA has one Head end Side Rail and Figure 7 one Foot end Side Rail on both sides of bed Figure 7 2 Side Rails are attached and operated by Latch Hinge mechanism 3 Pull bottom of Latch Hinge out
11. Accessories Mattress 1 2 Bari10A Bed may be equipped with BariMatt 1000 6 5 foam mattress Figure 18 p 12 Mattress designed as separate sections which fit together on Mattress Support Platform in different arrangements narrow sides extended or length extended Important Patient s risk for pressure ulceration determines which mattress should be used Assessment of risk for pressure ulceration is important to avoid injury to patient and should only be determined by qualified professionals Joernse Bariatric Beds Bari10A Model Note International standards require distance from top of mattress un compressed to top of Side Rails to be a minimum of 220 mm 8 66 inches If mattress is thicker than 6 5 Example If a professional recommends an air flotation system to treat pressure ulceration bed mattress system would not comply with International standards A professional can assess if clinical benefits outweigh the risk of not meeting standards 3 Mattress User Manual Figure 18 p 12 describes Mattress assembly and usage requirements Pendant Control Hang on Foot Panelard Route Pendant Control Cord inside Side Rails inside the Side Boards Figure 16 Figure 17 www joerns com info joerns com Joernse Bariatric Beds Bari1OA Model Overall dimension of assembled mattress is approximately 48 5 x 89 5 x 4 5 Left Side Extangion Main Matiass _ Right Side Extension
12. Cell Alkaline Batteries Environmental Conditions Operating Conditions Ambient Temperature 20 C to 30 C Relative Humidity 10 to 95 Non Condensing Storage and Shipping Conditions Ambient Temperature 30 C to 50 C Relative Humidity 10 to 95 Non Condensing Joerns Bariatric Beds Bari1OA Model Weight Change Mode mn ka Joernse Figure 20 Caution 5th Wheel must be disengaged to obtain an accurate resident patient weight www joerns com info joerns com Joernse Bariatric Beds Bari1 OA Model Scale System Functions and Weighing Procedures Caution 5th Wheel must be disengaged to obtain an accurate resident patient weight 0 0 Zero With all bed linens in place and without resident Weight Change Mode A Joernse Figure 21 Weight Mode If display shuts off before you can view weight data simply press the On button to refresh display and view resident patients weight Display will indicate patient in bed press Zero button Displayed WEIGHT XXX X LB or KG message will read PLEASE WAIT HANDS OFF Be sure nothing touches weight sensitive portion of integrated Scale System while performing zeroing function In a few seconds display will indicate WEIGHT 0 0 LB Caution After initialization process is complete and Scale System is still in Weight Change Mode do not press Zero button again or you will lose all stored resident patient s weigh
13. Warning Possible Shock Hazard Bed power cord has hospital grade 3 pronged grounded plug Grounding reliability can only be achieved when equipment is connected to an equivalent receptacle marked hospital grade If external grounding conductor is in doubt operate bed from backup battery Failure to do so could result in injury Warning Possible Equipment Damage Or Injury To Staff Members Service and repair must only be performed by qualified authorized Joerns Healthcare Technical Support personnel call 800 966 6662 AA Warning Explosion Hazard Do not use in the presence of flammable anesthetics gas or vapors Failure to heed this warning could result in equipment damage injury or death Caution Stay clear of underneath the bed when adjusting or moving the bed Caution Mattress Support Platform is not grounded nor does it have a potential equalization connection point To prevent injury to resident patient connected to intravascular or intercardial medical equipment alternate measure must be implemented to equalize the potential between Mattress Support Platform and medical equipment AA Warning To reduce the risk of injury ensure the sleep surface is horizontal and in the lowest position with the siderails fully raised and locked when moving the bed with a resident patient in it For best maneuverability performance push the bed from the head end To avoid injury to the resident patient and or user do not atte
14. ZE REFER TO MANUAL You must press Freeze Resume button to exit this mode Weight Change Mode This mode is used to monitor resident patient s weight changes Note To enable this function initially press Weight Change Mode button with On resident patient in bed and then press Zero button Button refreshes display or initiates power for to zero out weight Display will read scale use WT CHG resident patient weight Any variation in weight will now be viewed as a or figure relative to zero wvwvw joerns com info joerns com Scale System Calibration Figure 22 Periodic Calibration Check 1 Important Following calibration procedure should only be performed by qualified maintenance personnel 2 Load cell has no user serviceable components Do not tamper with for any reason 3 Re calibration is generally not required but should be verified periodically to ensure accuracy Joerns Healthcare recommends checking calibration check once every 12 months or as your maintenance policy requires Electrostatic Discharge ESD Integrated circuits and semiconductors on printed circuit boards may be damaged by electrostatic discharge ESD Be sure to use proper handling precautions at all times Calibration Procedure Note Make sure nothing is in contact with Scale System during this procedure Be sure to remove your hands from Scale System when noting displayed calibration results 1 Dis
15. atteries need replacement display will indicate CHANGE BATTERIES Remove Battery Cover from Foot Panel to access Scale System batteries Figure 23 Then remove all six batteries dispose used alkaline batteries per local codes and replace with alkaline D cell batteries 2 Printed circuit board vulnerable to electrostatic discharge ESD Avoid touching circuit board when changing batteries Battery orientation is illustrated on battery holder Cleaning Inspection and Maintenance Warning Disconnect Bari10A Power Cord from wall outlet before cleaning AA Warning Do not use power wash or high pressure cleaner on any Bari10A part Warning Lock all four Casters when cleaning inspecting or performing any maintenance of the Bari10A Lower all Mattress Support Platform sections unless necessary for positioning for service access Place all Selective Function Lockout switches in locked position Disconnect Power and Pendant Cords Caution It is critically important to lock all four casters individually 1 To achieve maximum usage and longest life for your Bari10A bed follow all warnings and cautions within this manual and maintain your bed with care as outlined below The maintenance required will be dictated by your bed s usage and care which should be inspected every six months 2 To optimize bed longevity a Keep bed clean b Observe bed usage and operation and report any discrepancies or proble
16. call Customer Care 800 826 0270 Save These Instructions Thank you and congratulations for choosing the Joerns Bari10A bed Joerns beds are developed with safety comfort and convenience of both resident patients and caregivers in mind Advanced ergonomic design will provide years of reliable service in your facility www joerns com info joerns com Joernse Bariatric Beds Bari1 OA Model Table of Contents Important Precautions E Entrapment Information tetteren Features amp Specifications nn Ens ARE EE denn Bed Operation sie tetteren e ee See DE Cleaning Inspection amp Maintenance Lubrication Servicing un ER ER ee Troubleshooting ees dede Appendix Diagrams EE WY dl OE denten Bed System Entrapment Information In recent years bedside rails have been a subject of regulatory review and evolution in design and use That focus includes not only the challenge of achieving an appropriate balance between resident security and unnecessary restraint but also the additional safety issue of entrapment The U S Food and Drug Administration FDA working with our company and other industry representatives has addressed the potential danger of entrapment with new safety guidelines for medical beds These guidelines recommend dimensional limits for critical gaps and spaces between bed system components Entrapment zones involve the relationship of components often directly assemb
17. ed may be overloaded or constrained from moving Determine load and check for obstructions If beeping occurs while raising or lowering bed Hi Low Actuators may have lost synchronization Lower bed to lowest position Release Bed Down button Press and hold Bed Down button for five seconds to recalibrate synchronization If problems persist contact Joerns Healthcare Technical Support at 800 966 6662 www joerns com info joerns com Joernse Bariatric Beds Baril OA Model Possible Cause What to Do Bed movement with all casters locked Scale System display is blank after On button is pushed Scale System gives suspect readings Mattress Support Platform sections do not extend Mattress Support Platform sections do not articulate Actuator piston rod will only move inwards and not outwards Actuator motor makes sound but piston rod does not move Actuator runs too slowly or does not give full force Braking mechanisms may be worn on one or more casters Batteries are dead Unit is defective Scale System cable is disconnected Scale System may need calibration oth Wheel is engaged Latch handles not fully disengaged Binding Pendant Control operation Selective function lockout may have been activated Unit may be defective or damaged Unit may be defective or damaged Possible synchronization problems Unit may be defective or damaged Unit is receiving insufficient power
18. engage 5th Wheel if equipped with optional steer pedal 2 Press Freeze Resume button 3 When display indicates FREEZE weight press and hold Lb Kg button Display will read CAL as right hand digit counts down to enter CAL MODE 4 When CAL MODE is shown press Zero button to zero the display 5 Place known calibrated weight onto weighing surface and compare it to displayed reading 6 Press Weight Mode button for corrections and Weight Change Mode button for corrections to displayed weight Displayed value should be within 0 5 of calibrated weight plus or minus one digit reeze Mode N Joernse Figure 22 Joernse Bariatric Beds Bari10A Model 7 Remove weight and re zero Repeat steps 4 5 and 6 until results are satisfactory 8 When adjustments are completed a Press on button to abort your changes and exit the CAL mode or b Press Freeze button to save all changes and exit CAL mode Calibration Tolerance Table Applied Load lbs 250 500 746 2 750 994 9 1000 1005 1 Scale System Care and Maintenance Cleaning 1 Mild soap water recommended for general cleaning disinfecting 2 Exercise caution when cleaning LED electronics display window Storage Remove batteries if storing this equipment for periods longer than three months Figure 23 www joerns com info joerns com Joernse Bariatric Beds Bari1 OA Model Battery Replacement 1 If Scale System b
19. ent Damage to the scale cable will result Figure 15 Photo taken from angle underneath bed VAT VA joerns com info joerns com Bed Movement Transport 1 Follow these general guidelines when moving bed specific patient s needs may necessitate such requirements a Fully lower all Mattress Support Platform sections b If extended retract Mattress Support Platform width extensions on both sides Note This may require removing mattress sections c If extended retract Mattress Support Platform Foot extension d Latch all Side Rails in up position e Required Place an attendant at each bed end f Caution Before transporting bed unplug bed from power source wrap Power Cord around Cord storage hooks below head Panel hang Pendant Cord from Foot Panel and route Pendant Cord inside Side Rails Figure 16 Failure to do so could result in Pendant Cord Power Cord or bed damage thereby creating a potential hazard Insure Pendant Cable and Power Cord are off floor and away from Casters g Unlock Casters h Deploy 5th Wheel if equipped with optional Steer Petal i Apply even push pull force on Head Panel and Foot Panel handholds Figure 17 When bed movement transport is completed e Always apply Caster Locks Caution It is critically important to lock all four casters individually to prevent unintended bed movement e Always plug bed back into power outlet so that it is continuously charging
20. l N A iA NOTES TEMDESCRPTION gem VOG system powered Load Cell Assy y Scales Display Assembl www joerns com info joerns com Joernse Bariatric Beds Bari1OA Model Notes www joerns com info joerns com Joernse Bariatric Beds Bari10A Model Notes www joerns com info joerns com Joernse Bariatric Beds Bari10A Model Joerns Healthcare Warranty Program for all Joerns Bari10A Beds Joerns Bari10A beds are guaranteed for a period of one year from the date of delivery against defects in materials and workmanship under normal use and service This one year warranty includes all mechanical and electrical components Steel structural components on beds are covered under warranty for a period of 10 years from the date of delivery Welds are covered under warranty for the lifetime of the product Damage caused by use in unsuitable environmental conditions abuse or failure to maintain the product in accordance with user and service instructions is not covered Any alteration modification or repair unless performed by or authorized in writing by Joerns Healthcare will void this warranty Parts Joerns beds contain various parts that wear from normal use These parts such as DC batteries are not covered under the one year warranty but are covered for 90 days after date of delivery 1 Intended product lifetime is 15 years Joerns Healthcare Inc 5001 Joerns Drive Stevens
21. led by the healthcare facility rather than the manufacturer Therefore compliance is the responsibility of the facility As the leading manufacturer of long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the expertise assistance and products to bring your facility into compliance www joerns com info joerns com Joernse Compliance Solutions Matching the right bed components in order to meet regulatory guidelines can be complex That s why Joerns offers a wide array of compliance options We assist customers in selecting compliant accessories recommended for their specific bed model For More Information To learn more about compliance options with Joerns products visit our website at www joerns com or contact our Customer Care reps at 800 826 0270 and ask for free informational publications To learn more about entrapment zones assessment methods and guidelines concerning entrapment contact Joerns Healthcare at 800 826 0270 or consult the FDA website www fda gov cdrh beds Features and Specifications Joernse Bari10A Standard Features e Fully articulated Mattress Support Platform with independent back and knee movement up down adjustments Trendelenburg and Reverse Trendelenburg positioning e 36 wide Mattress Support Platform sections easily expand to 48 wide e 80 expandable to 88 Mattress Support Platform Integrated foot end extension section
22. ll four sections on each side prior to adjusting bed position or Side Rails AAN Warning Use Width Extenders only after the resident patient is safely positioned in the bed Failure to do so could result in injury Mattress Support Platform Length Extender 1 Mattress Support Platform MSP Foot Section has an 8 Length Extender as does the foot end of the bed frame Figure 14 2 Both MSP Length Extender and the Frame Length Extender latch in the normal and extended positions 3 Using the MSP Length Extender is a two step process a Slide the Frame Extender out first by pulling out the latch knob on the side of the bed frame Figure 14 Begin carefully sliding the extender out and release the latch knob as soon as the extender starts to slide so that it will automatically latch again at the extended position Slowly pull the extender out until the latch pin clicks into its detent b Reach under the center of the MSP Foot Section and locate the MSP Extender latch knob Figure 15 Pull the knob out to unlatch the Foot Section Extender Begin carefully sliding the extender and release the latch knob as soon as the extender starts to slide so that it will automatically latch again at the extended position Slowly pull the extender out until the latch pin clicks into its detent Figure 14 Arrow indicates Length Extension Latch Warning Possible Equipment Damage Do not slide Frame Length Extender past its det
23. mpt to move the bed laterally with the steer mode engaged The steer wheel can not swivel Caution To avoid damage to the siderail mechanisms do not move the bed using the siderails Use the push pull handles integrated to the end panels to move the bed Joerns Bariatric Beds Bari1OA Model Caution Before transporting bed unplug bed from power source route Power Cord around Cord storage hooks on bed frame below Head Panel and hang Pendant Cord from Foot Panel Failure to do so could result in Power Cord Pendant Cord or bed damage thereby creating a potential hazard Failure to do so could result in Power cord Pendant Cord or bed damage thereby creating a potential hazard Caution Particular precaution must be considered during exposure to strong emission source such as High Frequency surgical equipment and similar devices Do not route High Frequency cables on or near device If in doubt contact a qualified technician When assessing the risk for entrapment you need to consider your bed mattress Head Foot Panels Side Rails Assist Device and other accessories as a system It is also extremely important to review the resident patient s physical and mental condition and initiate an appropriate individual care plan to address entrapment risk All Joerns bed systems are evaluated for compliance to the FDA CDRH Hospital Bed System Dimensional and Assessment Guidance to Reduce Entrapment For more information
24. ms to Joerns Healthcare Technical Support at 800 966 6662 c Check for loose bolts nuts or pins and report problems After a week of use check all bolts for any looseness and make sure all pins are in their normal location and fastened wvwvwv joerns com info joerns com d Check structural parts for any cracking especially welds bending or hole enlargement e Check wiring for proper connections and damage fraying kinking or deterioration Report any damage to Joerns Healthcare Technical Support at 800 966 6662 f Check Actuators for correct mounting at attachment points and insure all related pins are mounted securely and properly to frame Actuators are not serviceable If any discrepancies are noted during inspection they must be corrected before continuing bed usage Major service and repair must only be performed by authorized Joerns Healthcare Technical Support which you may contact at 800 966 6662 General Cleaning 1 For low level disinfecting wipe surfaces with a properly prepared detergent disinfectant 2 Do not use abrasive cleaners Use damp rag only when cleaning around electrical connectors and components 3 Actuator surfaces must be cleaned of dust and dirt regularly Do not attempt to clean exposed piston rods Never spray directly on Actuator with high pressure cleaners Storage 1 Store in a clean dry area Plug bed Power Cord into grounded hospital grade electrical outlet Act
25. t history Lb Kg Weight data may be viewed in either pounds or kilograms Pressing this button allows you to switch between display modes quickly and easily Both modes will display resident patient s weight within 0 1 units of resolution 0 1 Lb or 0 1 Kg Pressing Weight Mode button will switch back to the Weight Mode allowing you to view resident patients total weight again Caution If you do not press Freeze Resume button before adding removing items from bed the weight of those items will be reflected in the displayed weight which will be hard to adjust back to the correct stored weight Freeze Resume Freeze Resume mode button provides customized ability to adjust resident patient s comfort by adding removing a pillow or blanket or ancillary equipment without affecting resident patient s displayed weight Note You can correct any weight discrepancy described above by using Weight Mode for increases and Weight Change Mode for decreases buttons to manually adjust displayed weight reading You will need to know the weight of added removed items to add subtract from total weight Press Freeze Resume button The display will read FREEZE resident patients weight Make all necessary adjustments to bed or resident patient When done press Freeze Resume button again to resume normal weighing lf Freeze Resume mode is left unattended for more than three minutes display will read LEFT IN FREE
26. ttress Support Platform Use of an improperly fitted mattress could result in injury or death A Warning Possible Injury Or Death If a resident patients mental or physical condition could lead to resident patient entrapment the Mattress Support Platform should be left in the flat position when unattended Failure to do so could result in injury or death Warning Possible Injury Or Death Use a properly sized mattress in order to minimize the gap between the side of mattress and Side Rails Assist Devices This gap must be small enough to prevent resident patient from getting his her head or neck caught in this location Make sure that raising or lowering bed or articulating the sleep surface does not create any hazardous gaps Excessive gaps may result in injury or death Warning Possible Injury Or Death Do not use any Side Rails Assist Devices until you verify it is locked in place Failure to lock assist devices may result in injury or death Warning Possible Injury Or Death Do not use any replacement parts not manufactured marketed or provided by Joerns Healthcare on any Joerns bed Use of unapproved replacement parts may result in injury or death Warning Possible Injury Or Death If using accessories not manufactured marketed or provided by Joerns Healthcare for Joernse beds consult with the manufacturer for compatibility and limitations prior to use Failure to do so may result in injury or death AA
27. uator Control System backup batteries maintain the longest life if kept charged and are not allowed to fully discharge 3 Failure to keep Bari10A bed plugged in will discharge backup batteries and shorten their life 4 If storing bed for periods longer than three months remove all Scale System batteries Joernse Bariatric Beds Bari10A Model Lubrication Servicing Recommended Lubricants 1 Oil Use 3 In Onee oil or equivalent 2 Grease Use Super Lubee synthetic grease or equivalent Oiling Points 1 Keep pins and bolts oiled sample indicated by arrows in Figure 24 2 Oil hinge points sample indicated by arrows in Figure 25 Grease Points For Mattress Support Platform 1 Grease Side and Foot Extensions sample indicated by arrows in Figure 26 amp 27 Figure 26 Figure 27 www joerns com info joerns com Joernse Bariatric Beds Bari1 OA Model Bari10A Bed Troubleshooting Pendant Control Troubleshooting If adjustment does not occur when Pendant button is pushed If Adjustment Only partially occurs stops and beeps Adjustment may be locked Check Selective Funtion Lockout Adjustment may already be at maximum level Bed is not plugged into wall power outlet and battery has discharged Plug bed into wall outlet Pendant cord may be damaged Check cord for damage If cord is damaged discontinue bed usage until cord is replaced Battery may be low Plug bed into power source B
28. use binding during removal and replacement 3 To minimize binding grasp Head Panel or Foot Panel at both lower corners and lift push evenly Installation Of Head And Foot Panels 1 Insert Head and Foot Panel support rods into their respective receptacles in the frame Figure 1 Note Scale System Display located on outside of Foot Panel must face away from bed Figure 1 2 Connect Scale System quick release electrical connector from the bed to Foot Panel rear bottom fixed connector Figure 2 Note This is a quarter turn fastener Check to insure it is firmly secured 3 Power Cord supplies power to bed s Actuator System Plug Power Cord into grounded hospital grade receptacle 115VAC 15 amps Note To achieve optimum Actuator System battery life keep the bed plugged in at all times 4 Power cord is the main disconnect device To disconnect the mains unplug Power Cord Control Backup Battery powers the Actuators when cord is unplugged 5 Whenever bed is cleaned or serviced it should be unplugged from wall power Selective Function Lockout should be set to Lock for all functions to keep bed from accidentally operating using battery backup Note To avoid electric shock always plug bed into properly grounded hospital grade receptacle 6 Actuator battery backup is not user serviceable If service is required contact Joerns Healthcare Technical Support at 800 966 6662 Head Panel Foot Panel shown with scales
29. wards to lower Side Rails Figure 8 Note Latch Hinge locks Side Rail only in up position 4 Lower Side Rails gently Figure 5 Mack Aanias Hi L Teanga laii Bran ELETE Figure 8 Bire Raia Figure 6 Pendant Lockout Operation 1 Rotate Switch to Lock Unlock Back Raise Function 2 Rotate Switch to Lock Unlock Hi Lo Trendelenburg Function 3 Rotate Switch to Lock Unlock Knee Raise Function wvwvw joerns com info joerns com Joernse Bariatric Beds Bari10A Model Casters 1 All 4 Casters securely lock bed in place 2 All Casters have full swivel rotation locking in any position 3 Simply push Caster Lock Lever Figure 9 down to lock and up to unlock Figure 10 Caution It is critically important to lock all four casters individually to prevent unintended bed movement Steer Pedal optional A bed equipped with this option has a fifth wheel Figure 9 activated by lateral brake steer pedals on either side of the bed The fifth wheel helps in guiding the bed along a straight line and helps the bed pivot around corners Warning To reduce the risk of injury ensure the sleep surface is horizontal and in the lowest position with the siderails fully raised and locked when moving the bed with a resident patient in it For best maneuverability performance push the bed from the head end A Warning oth wheel must be disengaged to use scale To avoid injury to the resident patient and or user do

Download Pdf Manuals

image

Related Search

Related Contents

Emerson (K490) Diagrams and Drawings  SITOGRAPHIE  Philips Spiral 929689647402  Untitled  Manual Utilização Geo Coleta - Tribunal de Contas do Estado de  Winner Every Time Service Manual 11-01-07.pub  Samsung GU10 PAR16 9.5W  Bedienungs- anleitung  Thèse 2. Evolution du processus vocationnel chez le grand  Notice - Castorama  