Home
Ultramat® UFM-D130
Contents
1. Caution Malfunctions in the application Through incorrect installation and insufficient maintenance the D130 can malfunction Condensate which is not discharged can lead to damage to plants and in manufacturing processes Measures Fail safe condensate discharge directly optimises the compressed air quality To prevent damage and failures it is imperative To comply with the provisions regarding proper use and with the operating parameters of the D130 in connection with the case of application see chapter Proper use To strictly adhere to the installation and operating advice in these instructions To maintain and check the D130 at regular intervals in accordance with the advice in these operating instructions Proper use The D130 is an electronically level controlled condensate drain for compressed air plants It is employed within the permissible operating parameters see Technical data The D130 is able to drain condensate under operating pressure from the plant components virtually without compressed air losses For its function the D130 14 requires an operating voltage and an operating pressure see Technical data As far as the employment in plants with increased demands on the compressed air quality is concerned food industry medi cal technology laboratory equipment special processes etc the operator must decide on measures for the monitoring of the compressed air quality These have an
2. Pull cable E F tight and screw down cable fittings Screw power supply board G with screw D into domed cover A Plug ribbon cable H into control PCB K If the individual wires have not been screwed into the plug they should be attached as follows 1 0 brown 1 1 blue 2 0 black Put on top of cover A and tighten the 4 screws B Please note The power supply board C is in a reverse position upside down in the domed cover A During no load operation a voltage of up to 36 VDC may be measured at terminals 1 0 and 1 1 plug ribbon cable H D130 espa ol fran ais portugu s Consulte la tensi n de red admisible en la placa identificativa G Realice los trabajos de instalaci n acorde a la VDE 0100 IEC 60364 No realice la instalaci n bajo tensi n Desmontar la tapa de la carcasa A despu s de soltar los 4 tornillos B Sacar la platina de la fuente de alimen taci n C de la tapa de la carcasa A despu s de soltar el tornillo D Introducir el cable de alimentaci n el c trica E y el contacto libre de potencial F a trav s de las gu as correspon dientes Asignaci n de bornes Alimentaci n el ctrica VAC 0 0L 0 1 N 0 2 PE Alimentaci n el ctrica 24 VDC 24 VDC 0V OV 24 VDC En funcionamiento con 24 VDC la masa no podra conectarse a plus 24 VDC ya que en el interior del aparato el negativo esta conectado al pote
3. Use pressure resistant installation material only The feed pipe must be tubed firmly Discharge pipe short fixed pressure hose onto pressure resistant pipe Make sure that persons or objects cannot be hit by condensate or escaping compressed air Caution Malfunctions in the application Through incorrect installation and insufficient maintenance the D130 can malfunction Condensate which is not discharged can lead to damage to plants and in manufacturing processes Measures Fail safe condensate discharge directly optimises the compressed air quality To prevent damage and failures it is imperative To comply with the provisions regarding proper use and with the operating parameters of the D130 in connection with the case of application see chapter Proper use To strictly adhere to the installation and operating advice in these instructions To maintain and check the D130 at regular intervals in accordance with the advice in these operating instructions O Note It is imperative to observe all hazard statements and warnings listed here Please also observe all regulations and notes regarding the industrial safety and fire prevention at the respective place of installation As a matter of principle only use suitable and appropriate tools and materials in a proper condition Do not use aggressive cleaners and improper devices such as high pressure cleaners Please note that condensates may contain aggressive or
4. o de acordo com a finalidade Observa o precisa das indica es sobre instala o e opera o contidas nas presentes instru es Manuten o regular e controle do D130 segundo as indica es contidas nas presentes instru es Utiliza o de acordo com a finalidade O D130 um condutor de descarga de condensado com regula o eletr nica de n vel e destinado a equipamentos de ar comprimido A utiliza o feita no mbito dos par metros operacionais admiss veis ver Dados T cnicos O D130 pode descarregar condensado das partes do equipamento sob press o de servi o e praticamente sem perda de ar comprimido Para funcionar o D130 precisa de uma tens o de servi o e de uma press o de servi o ver Dados T cnicos No caso de utiliza o em equipamentos com elevadas exig ncias qualidade do ar comprimido ind stria aliment cia ele tromedicina equipamentos de laborat rio processos especiais etc a entidade exploradora ter que decidir sobre medidas relativas monitora o da qualidade do ar comprimido Tais medidas exercem influ ncia sobre a seguran a dos processos seguintes podendo evitar danos em pessoas e equipamentos Cabe entidade exploradora garantir as citadas condi es durante todo o per odo de funcionamento Para o emprego em equipamentos CO2 necess rio utilizar um D130 com a especifica o CO D130 CO O D130 e a tubula o condutora de condensado deve
5. 34 D130 espa ol fran ais portugu s Posibles causas tensi n de la entrada no correcta fuente de alimentaci n defectuosa circuito de pilotaje defectuoso lea la tensi n de la etiqueta identifica tiva compruebe la tensi n de la fuente de alimentaci n en los bornes 0 0 0 1 0 2 compruebe la tension de 24 VCC del circuito de pilotaje en los bornes 1 0 1 1 sin carga hasta 36 VCC compruebe la conexi n del conector del cable plano Origines possibles D faut d alimentation lectrique Carte d alimentation d fectueuse Carte de commande d fectueuse Relever la tension sur la plaque V rifier la tension sur la carte d alimen tation aux bornes 0 0 0 1 0 2 V rifier la tension de 24 VDC sur la carte de commande aux bornes 1 0 1 1 mesurable sans charge jusqu 36 VDC V rifier liaison enfichable c ble en nappe Causas possiveis erro na alimenta o de tens o fonte de alimenta o defeituosa placa de comando defeituosa ver na placa indicadora a tens o cor recta verificar tens o dos bornes 0 0 0 1 0 2 na placa de alimenta o a partir da rede verificar tens o 24 VDC dos bornes 1 0 1 1 na placa de comando sem carga pode ser medida at 36 VDC verificar conex o da ficha cabo em fita Posibles causas la tuber a de la entrada y o la tu beria de la salida est n obstruidas desgaste la platina de pilotaje est d
6. cycles de man uvre de l lectrovanne par l interm diaire d un contact sans potentiel relais K2 Exclusion du domaine d application En tant que purgeur de condensat le D130 ne peut pas garantir lui seul une qualit d air comprim d finie pour ce faire il faut d autres quipements techniques en plus Le D130 ne convient pas pour l utilisation sur des installations sous vide ou fonctionnant la pression atmosph rique am biante ni pour l utilisation dans les atmosph res explosibles Le D130 ne doit pas tre expos en permanence au rayonnement direct du soleil ou un rayonnement thermique Le D130 ne doit pas tre install ni utilis dans les domaines expos s une atmosph re agressive D130 Indica es de seguran a Favor verificar se as presentes instru es correspondem ao tipo de aparelho AR Observar todas as advert ncias contidas nas presentes instru es de servico As instru es cont m indica es b sicas que dever o ser observadas durante a montagem a opera o e a manuten o Por esses motivos antes da instala o da coloca o em servi o e dos trabalhos de manuten o estas instru es dever o ser lidas sem falta pelo t cnico de montagem pelo cliente e pelo pessoal t cnico As instru es dever o estar sempre dispon veis junto do local de utiliza o do D130 Adicionalmente a estas instru es tamb m dever o ser observadas as diretivas locais e ou
7. de la m quina Por este motivo es imprescindible que tanto el t cni co de instalaci n como los operarios y personal responsable lo lean antes de realizar trabajos de instalaci n puesta en marcha y mantenimiento El manual de instrucciones deber estar disponible en todo momento en el lugar de instalaci n del D130 Adem s de las indicaciones contenidas en el manual deber n respetarse las normativas vigentes locales y naciona les que correspondan Aseg rese de que el D130 solamente se pone en marcha dentro de los valores l mite admisibles indicados en la placa identificativa De otra manera podr an ocasionarse da os a personas y objetos as como aver as Si tiene alguna dificultad para entender el contenido del manual o quiere hacer alguna consulta le rogamos que se ponga en contacto con Donaldson Peligro A jAire comprimido Un golpe de aire comprimido que escapa repentinamente o por componentes de la m quina que salgan disparados por su efecto puede suponer peligro de graves lesiones o muerte Medidas preventivas No sobrepasar la presi n m x de funcionamiento ver placa identificativa Realice los trabajos de mantenimiento siempre con la m quina despresurizada Utilice solamente materiales resistentes a la presi n para la instalaci n Apretar bien la conducci n de alimentaci n Conducci n de salida manguera de presi n corta fijada a una tuber a resistente a la presi n Haga lo posible para ev
8. doit tre disponible et accessible tout moment sur le lieu d utilisation du D130 En plus de ce mode d emploi il faut respecter les ventuelles prescriptions locales ou nationales Assurez vous que le D130 ne soit utilis qu au sein des valeurs limites admissibles et mentionn es sur la plaque signal tique Dans le cas contraire il peut pr senter un risque pour les personnes et le mat riel voire nuire au bon fonctionnement de l installation ou g n rer des perturbations Si certains points ne sont pas clairs ou si vous avez des questions au sujet de ces instructions de montage et de ser vice n h sitez pas contacter la soci t Donaldson V rifiez que cette notice corresponde bien au mod le d appareil en votre possession Danger A Air comprim Tout contact avec de l air comprim s chappant rapidement ou de fa on brutale ou tout contact avec des parties de l installation pr sentant un risque d clatement peut causer de graves blessures ou entra ner la mort Mesures pr ventives Ne pas d passer la pression de service maximale voir plaque signal tique D pressuriser le purgeur avant toute intervention d entretien ou de maintenance N utiliser que du mat riel d installation r sistant la pression La conduite d amen e doit toujours tre r alis e en tuyauterie rigide et fixe Conduite d vacuation flexible de faible lon gueur fix et reli une tuyauterie tous deux r sistant l
9. du montage utiliser le m plat pour cl au niveau de l arriv e 36 mm pour maintenir le purgeur pendant le serrage D130 Prudence N Dysfonctionnements au niveau de I utilisation En cas d installation incorrecte et de maintenance insuffisante des dysfonctionnements peuvent appara tre au niveau du D130 Tout condensat non vacu risque d endommager les installations et de porter atteinte aux processus de fabrication Mesures pr ventives Le bon fonctionnement de la purge des condensats permet une optimisation directe de la qualit de I air comprim Pour viter tout endommagement et tout arr t de production il est imp ratif de respecter les consignes suivantes Respecter scrupuleusement les instructions pour une utilisation conforme l usage pr vu et les param tres de fonctionnement du D130 dans le contexte de son utilisation consulter cet effet le chapitre Utilisation conforme l usage pr vu Respecter scrupuleusement toutes les instructions d installation et d utilisation communiqu es dans cette notice Respecter scrupuleusement la p riodicit de maintenance et de contr le du D130 selon les indications de ce manuel d utilisation Utilisation conforme l emploi pr v Le D130 est un purgeur de condensat r gulation lectronique de niveau pour les installations de production et distribution d air comprim L utilisation s effectue dans le respect des param tres de f
10. harmful components Therefore skin contact should be avoided Condensate is subject to mandatory waste disposal and must be collected in suitable containers and disposed of or processed properly 14 D130 Instalacion Peligro N Aire comprimido Un golpe de aire comprimido que escapa repentinamente o por componentes de la m quina que salgan disparados por su efecto puede suponer peligro de graves lesiones o muerte Medidas preventivas No sobrepasar la presi n m x de funcionamiento ver placa identificativa Realice los trabajos de mantenimiento siempre con la m quina despresurizada Utilice solamente materiales resistentes a la presi n para la instalaci n Apretar bien la conducci n de alimentaci n Conducci n de salida manguera de presi n corta fijada a una tuber a resistente a la presi n Haga lo posible para evitar que personas u objetos puedan ser alcanzados por escapes de aire comprimido Precauci n N iMal funcionamiento Una instalaci n incorrecta y la falta de mantenimiento pueden provocar que el D130 funcione mal El condensado no evacuado puede provocar da os en las instalaciones y en los procesos de producci n Medidas preventivas Una evacuaci n segura del condensado optimiza la calidad del aire comprimido de manera directa Tenga en cuenta los puntos siguientes para prevenir da os y paradas en la producci n Respeto del uso apropiado y de los par metros de
11. intervention d entretien ou de maintenance N utiliser que du mat riel d installation r sistant la pression La conduite d amen e doit toujours tre r alis e en tuyauterie rigide et fixe Conduite d vacuation flexible de faible lon gueur fix et reli une tuyauterie tous deux r sistant la pression Veillez ce qu aucune personne ni objet ne risque d tre touch par le condensat ou l air comprim qui s chappe Prudence A Dysfonctionnements au niveau de l utilisation En cas d installation incorrecte et de maintenance insuffisante des dysfonctionnements peuvent appara tre au niveau du D130 Tout condensat non vacu risque d endommager les installations et de porter atteinte aux processus de fabrication Mesures pr ventives Le bon fonctionnement de la purge des condensats permet une optimisation directe de la qualit de l air comprim Pour viter tout endommagement et tout arr t de production il est imp ratif de respecter les consignes suivantes Respecter scrupuleusement les instructions pour une utilisation conforme l usage pr vu et les param tres de fonc tionnement du D130 dans le contexte de son utilisation consulter cet effet le chapitre Utilisation conforme l usage pr vu Respecter scrupuleusement toutes les instructions d installation et d utilisation communiqu es dans cette notice e Respecter scrupuleusement la p riodicit de maintenance et de contr l
12. max pour la zone climatique Bleu voir aussi chapitre Zones climatiques et Capacit s Pot ncia maxima para zona climatica azul ver tamb m o capitulo Zona climatica e dados de pot ncia peak compressor performance Caudal max del compresor Capacit maximale du compresseur 5 400 scfm Pot ncia max do compressor Peak refrigeration dryer performance only with pre separation Capacidad m x del secador frigor fico con preseparaci n 10 800 scfm Capacit maximale du s cheur frigo seules avec pr separation Pot ncia maxima do secador a frio s com pr precipita o Peak filter performance behind dryer Capacidad m x de filtraci n detr s del secador Capacit maximale du filtre en aval du s cheur 54 000 scfm Pot ncia maxima do filtro ap s o secador 10 D130 Electrical data Datos el ctricos Caract ristiques electrique Dados el ctricos Supply voltage Tension de funcionamiento Tension d alimentation Tens o operacional 230 115 24 VAC 10 50 60 Hz 24 VDC 10 see type plate ver placa identificativa voir plaque signal tique vide placa de caracteristicas Power consumption Potencia consumida Consommation Consumo de pot ncia P lt 8 0 VA W Fuse protection Fusible Fusibles Fusivel recommanded AC 1 A slow stipulated DC 1 A slow recomend para AC 1 Alento obligatorio para DC 1 A lento recom
13. no se evacua La touche Test est actionn e mais sans purge du condensat Botao de teste premido mas nao ha descarga de produto de condensa o Possible causes Feed and or outlet line shut off or blocked Worn parts Control PCB defective Solenoid valve defective Check feed line and outlet line Replace worn parts Check if valve opens audibly press test button several times Check 24 VDC voltage on control PCB at terminals 3 0 3 1 3 2 without load up to 36 VDC may be measured Condensate discharge only when test button is being pressed Evacuaci n del condensado sol si est pulsado el interruptor de TEST Purge du condensat uniquement si la touche Test est actionn e Descarga de produto de condensac o s com o bot o de teste premido Possible causes Feed line with insufficient slope Excessive condensate quantities Sensor tube extremely dirty Dropping below necessary minimum pressure Lay feed line with adequate slope Install venting line Clean sensor tube Ensure minimum pressure otherwise install low pressure or vacuum conden sate drain Device keeps blowing off air El aparato esta abierto constantemente L appareil refoule de l air en permanence Aparelho deixa continuamente escapar ar Possible causes Control air line blocked Worn parts Clean entire valve unit Replace worn parts Clean sensor tube
14. por componentes de la m quina que salgan disparados por su efecto puede suponer peligro de graves lesiones o muerte Medidas preventivas No sobrepasar la presi n m x de funcionamiento ver placa identificativa Realice los trabajos de mantenimiento siempre con la m quina despresurizada Utilice solamente materiales resistentes a la presi n para la instalaci n Apretar bien la conducci n de alimentaci n Conducci n de salida manguera de presi n corta fijada a una tuberia resistente a la presi n Haga lo posible para evitar que personas u objetos puedan ser alcanzados por escapes de aire comprimido iPeligro iCorriente el ctrica El contacto con componentes sometidos a tensi n y sin aislamiento acarrea peligro de sufrir descargas el ctricas que deriven en heridas o muerte Medidas preventivas Al realizar la instalaci n el ctrica respete todas las normativas vigentes por ejemplo la VDE 0100 IEC 60364 Realice siempre los trabajos de mantenimiento con la m quina desconectada de la red el ctrica Los trabajos el ctricos deber n dejarse en manos de personal autorizado y cualificado Precauci n Mal funcionamiento Una instalaci n incorrecta y la falta de mantenimiento pueden provocar que el D130 funcione mal El condensado no evacuado puede provocar da os en las instalaciones y en los procesos de producci n Medidas preventivas Una evacuaci n segura del condensado optimiza la cal
15. protector la conexi n de PE y la red de tuber as no debe haber diferencia de potencial En caso necesario deber instalarse una conexi n equipotencial acorde a la VDE 0100 IEC 60364 D130 23 Installation lectrique Danger Tension lectrique Tout contact avec des l ments non isol s et sous tension pr sente un risque de choc lectrique pouvant provoquer des blessures ou entra ner la mort Mesures pr ventives Lors de la r alisation de l installation lectrique respecter toutes les prescriptions en vigueur p ex VDE 0100 IEC 60364 Avant toute intervention d entretien ou de maintenance mettre le purgeur HORS TENSION Toute intervention lectrique doit tre r alis e exclusivement par un personnel qualifi et habilit En cas d alimentation en courant alternatif CA il est imp ratif de pr voir proximit un dispositif de sectionne ment accessible par ex une fiche secteur ou un interrupteur qui coupe tous les conducteurs v hiculant le courant lectrique Si le contact sans potentiel v hicule des tensions lectriques dangereuses en cas de contact il est imp ratif de pr voir un dispositif de sectionnement comme d crit plus haut La tension continue de 24 VDC mise disposition doit r pondre aux exigences pour les Tr s Basses Tensions de Protec tion T B T P avec s paration s curis e par rapport la tension secteur PELV Protection by Extra Low Voltage sel
16. rojo parpadea despu s de 1 min la se al de alarma se conecta Test de fonctionnement du D130 Pression br ve sur la touche Test 2 sec La soupape s ouvre pour la purge V rification du signal d alarme Obturer l arriv e de condensat Presser la touche Test pendant 1 min au moins La LED rouge clignote apr s 1 min Le signal d alarme est activ Testar o funcionamento do D130 Premir brevemente o bot o de teste Av lvula abre se para escoamento do condensado Controlar o sinal de alarme Fechar a aflu ncia de condensado Premir pelo menos 1 minuto o bot o de teste LED vermelho pisca passado 1 min O sinal de alarme activado D130 33 Trouble shooting Busqueda de fallos Recherche de panne Localizac o de erros english Alarm O Valve O rf Power D y No LED lighting up Ning n LED est iluminado Aucune LED n est allum e Todos os LEDs apagados Possible causes Power supply faulty Power supply board defective Control PCB defective Check voltage on type plate Check voltage on power supply board at terminals 0 0 0 1 0 2 Check 24 VDC voltage on control PCB at terminals 1 0 1 1 without load up to 36 VDC may be measured Check plug connection ribbon cable Pressing of test button but no condensate discharge El interruptor de TEST est pulsado pero el condensado
17. servicio del D130 teniendo en cuenta el campo de aplicaci n de cada caso v ase cap tulo Uso apropiado Observaci n estricta de las indicaciones de instalaci n y servicio facilitadas en este manual Mantenimiento regular y control del D130 acorde a las indicaciones del manual D Atenci n Tenga siempre en cuenta todas las indicaciones de peligro y advertencia facilitadas Observe igualmente todas las normativas e indicaciones de protecci n en el trabajo y contra incendios all donde se efect e la instalaci n Utilice Unicamente herramientas y materiales adecuados y en buen estado No utilice detergentes agresivos ni herramientas inadecuadas como limpiadores a alta presi n Tenga en cuenta que el condensado puede contener componentes agresivos y dafiinos para la salud Por esa raz n deber evitarse siempre el contacto con la piel El condensado es un residuo que el usuario est obligado a gestionar correctamente recogi ndolo en recipientes adecuados para luego eliminarlo o tratarlo D130 15 Installation Danger Air comprim Tout contact avec de l air comprim s chappant rapidement ou de fa on brutale ou tout contact avec des parties de l installation pr sentant un risque d clatement peut causer de graves blessures ou entra ner la mort Mesures pr ventives Ne pas d passer la pression de service maximale voir plaque signal tique D pressuriser le purgeur avant toute
18. 364 4 41 eG Atenci n Entre los bornes de conexi n KL 1 1 1 3 de los aparatos VDC y las carcasas o las conexiones de condensado hay un aisla miento galv nico Al efectuar controles por ejemplo de los conductores protectores acorde a la VDE 0701 0702 IEC 85 361 CD deber tenerse en cuenta que s lo existe una conexi n para crear una puesta a tierra funcional entre las piezas conductoras susceptibles de contacto y el soporte del condutor protector pero que no hay una conexi n de protecci n resistente a la corriente Apretar la atornilladura del cable de forma que hermetice ligeramente Contacto libre de potencial Es posible transmitir la se al de alarma por ejemplo al puesto de mando por medio del contacto libre de potencial El con tacto de conmutaci n puede funcionar en modo fail safe por ejemplo Si hay tensi n de funcionamiento y el D130 est en marcha sin presentar aver as el rel de alarma estar activado El contacto 0 7 0 8 est cerrado Si no hay tensi n de funcionamiento o existe un aviso de aver a el rel de alarma descargar El contacto estar abierto alarma Tecla de test externa opcional Gracias a ella puede purgarse el condensado acumulado por control remoto La funci n normal de la tecla de test ist hier zus tzlich aus dem D130 herausgef hrt Cuando el contacto externo se cierra la v lvula se abre Tenga en cuenta las indi caciones del manual adicional Entre el conductor
19. D130 35 Dimensions Dimensiones Dimensions Dimens es A G NPT x e e st G3 NPT 34 gt e y v di 13 dia Y 252 9 9 lt x o N v D130 36 PA 5 Technical alterations reserved Sous r serve de modifications technicques Alteraciones t cnicas reservadas Donaldson FILTRATION SOLUTIONS Donaldson Company Inc Compressed Air amp Gas P O Box 1299 Minneapolis MN 55440 1299 U S A Tel 800 543 3634 Fax 952 885 4791 www donaldson com 1C892314 2011 04
20. Operation Manual O Donaldson Ultrafilter Manual de uso Instructions de montage et de service Manual de Instru es RO2 01 04 2011 Ultramat UFM D130 A amp Originalanleitung in Deutsch Donaldson Safety instructions Please adhere to all advice given in these operating instructions They include basic information which needs to be observed during installation operation and maintenance Therefore it is vital for the technician and the responsible operator skilled personnel to read these operating instructions prior to installation start up and maintenance The operating instructions must be accessible at all times at the place of application of the D130 In addition to these operating instructions local and national regulations need to be observed if required Make sure that the D130 is operated only within the permissible limit values indicated on the type plate Any deviation involves a risk for persons and materials and may result in malfunction and service failures If you have any queries regarding these installation and operating instructions please contact Donaldson Please check whether or not these instructions correspond to the device type Danger A Compressed air Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or through bursting plant components or plant components which are not secured Measures Do not exceed the maximum o
21. a e a uma manuten o insuficiente poss vel que ocorra o mau funcio namento do D130 O condensado n o evacuado poder causar danos em equipamentos e em proces sos de fabrica o Medidas a serem tomadas Uma descarga perfeita do condensado otimiza diretamente a qualidade do ar comprimido Para evitar danos e falhas favor observar sem falta Observa o precisa da utilizac o de acordo com a finalidade e dos par metros operacionais do D130 em ligac o com o caso de utiliza o ver a este respeito o cap tulo Utiliza o de acordo com a finalidade Observa o precisa das indica es sobre instala o e opera o contidas nas presentes instru es Manuten o regular e controle do D130 segundo as indica es contidas nas presentes instru es o Observa o Prestar aten o sem falta a todas as indica es de perigo e advert ncias Observar igualmente todos os regulamentos referentes seguran a no trabalho e prote o contra inc ndios S devem ser usadas ferramentas apropriadas e materiais em perfeito estado N o utilizar produtos de limpeza agressivos nem aparelhos inadequados tais como equipamentos de limpeza a alta press o N o esquecer que os condensados podem conter elementos agressivos e nocivos sa de Por isso evitar qualquer contato com a pele Condensado um res duo sujeito destina o final que dever ser recolhido em recipientes apropriados levado destina o
22. a peau Les condensats sont soumis a la r glementation sur les d chets Ils doivent tre collect s dans des r cipients appropri s limin s ou recycl s 30 D130 Controle e manuten o Perigo Ar comprimido O contato com ar comprimido escapando r pida ou repentinamente ou pecas que rebentam e ou que nao est o fixadas podem provocar ferimentos graves ou a morte Medidas a serem tomadas T o ultrapassar a press o maxima de servi o ver placa de caracter sticas Trabalhos de manuten o s devem ser executados com o sistema despressurizado S usar material de instala o prova de press o Montar de modo fixo a tubula o de admiss o Tubula o de descarga mangueira de press o curta e ligada a um tubo a prova de press o impedir que pessoas ou objetos possam ser atingidos pelo condensado ou pelo ar comprimido que escapa Perigo Tens o de rede Devido ao contato com pe as n o isoladas e condutoras da tens o de rede existe o perigo de choque el trico com ferimentos e morte Medidas a serem tomadas Na instala o el trica dever o ser observadas todas as diretiva vigentes p ex VDE 0100 IEC 60364 Trabalhos de manuten o s devem ser executados com o sistema desenergizado Todos os trabalhos el tricos s poder o ser efetuados por pessoal especializado e autorizado Cuidado N Mau funcionamento na aplica o Devido a uma instala o incorret
23. a pression Veillez ce qu aucune personne ni objet ne risque d tre touch par le condensat ou l air comprim qui s chappe Danger A Tension lectrique Tout contact avec des l ments non isol s et sous tension pr sente un risque de choc lectrique pouvant provoquer des blessures ou entra ner la mort Mesures pr ventives Lors de la r alisation de l installation lectrique respecter toutes les prescriptions en vigueur p ex VDE 0100 IEC 60364 Avant toute intervention d entretien ou de maintenance mettre le purgeur HORS TENSION Toute intervention lectrique doit tre r alis e exclusivement par un personnel qualifi et habilit Autres consignes de s curit Lors de l installation et de l utilisation il faut galement respecter les directives et consignes de s curit en vigueur dans le pays en question Ne pas utiliser le D130 dans les atmosph res explosibles viter les serrages trop importants au niveau des raccords de la conduite d amen e Ceci est valable en particulier pour les raccords filetage conique Le D130 n est op rationnel que s il est sous tension alimentation lectrique assur e Ne pas utiliser le bouton Test pour l vacuation permanente du condensat Utiliser exclusivement des pi ces de rechange d origine Seul le respect scrupuleux des consignes donn es peut garantir le parfait fonctionnement de l appareil Consignes suppl mentaires Lors
24. advisable to arrange the piping so that the air flow is diverted 18 D130 espa ol fran ais portugu s 1 Tuberia de entrada y piezas de co nexi n m n 3 4 di metro interior gt 18 mm 2 No ponga ningun filtro en la tuber a de entrada 3 Latuber a delaentradatiene quetener una pendiente descendente constante 2196 4 Utilice solamente llaves de paso es f ricas 5 Presi n de funcionamiento m n 0 8 bar o 1 2 bar lea la presi n indicada en la etiqueta de identificaci n 6 Tubo a presi n corto 7 Porcadametro que asciende latuber a de salida se incrementa la presi n m nima de funcionamiento en 0 1 bar Subida m xima de la tuber a de salida 5 m 8 Tuber a colectora de los condensa dos m n 1 con pendiente descen dente constante 1 9 Si existieran problemas de entrada instalar una tuber a de ventilaci n 1 Tube d amen e au moins 3 4 Diametre interieur 18 mm 2 Pas de filtre sur l amen e 3 Pente de l amen e gt 1 4 Utiliser uniquement des vannes boisseau sph rique 5 Pression minimum 0 8 ou 1 2 bar relever la pression sur la plaque 6 Flexible pression de faible longeur 7 Pour chaque m tre de pente mon tante sur la conduite d vacuation il faut augmenter la pression minimale requise de 0 1 bar Evacuation longueur max de la partie montante 5m 8 Conduite collectrice au minimum 1 avec 1 de pente 9 La con
25. ater pockets when using a pressure hose as a feed line Note Continuous slope Water pockets must also be avoided when laying a feed pipe 20 D130 espa ol fran ais portugu s Observe pendiente descendente constante La tuberia de la entrada tiene que tener siempre una pendiente descen dente constante Si no hay suficiente altura se tiene que emplear la entrada inferior con en tuberia de compen saci n Important pente continue La conduite d arriv e doit toujours tre r alis e avec une pente continue En cas de hauteur de montage limit e utiliser l entr e du bas et r aliser une conduite s par e d quilibrage d air Importante declive continuo Assentar o tubo adutor sempre com de clive continuo Se o espaco de instala o for reduzido equipar o tubo adutor da parte de baixo com um tubo separado de evacua o do ar Observe compensaci n Si hay un flujo de condensado alto se tiene que instalar una tuberia de com Important conduite d quilibrage d air En cas de forte production de condensat il faut toujours installer une conduite s Importante tubo de evacua o do ar No caso de incid ncia de altas quanti dades de condensado deve instalar se pensaci n par e d quilibrage d air sempre um tubo separado de evacua o do ar Observe Im
26. balhos el tricos s poder o ser efetuados por pessoal especializado e autorizado Outras indicac es de seguranca Durante a instala o e a opera o tamb m devem ser observadas as diretivas e as instru es de seguran a nacionais N o utilizar o D130 em reas com perigo de explos o Nas uni es roscadas de alimenta o evitar for as de aperto excessivas Isso aplica se especialmente a uni es roscadas c nicas O D130 s est operacional se tiver tens o aplicada O bot o de teste n o dever ser utilizado para a drenagem permanente Utilizar exclusivamente pe as de reposi o originais S assim ficar garantido um funcionamento perfeito Indica es adicionais Durante a montagem utilizar as superf cies das chaves na parte de alimenta o tamanho SW36 para segurar D130 Cuidado Mau funcionamento na aplica o Devido a uma instala o incorreta e a uma manutenc o insuficiente possivel que ocorra o mau funciona mento do D130 O condensado n o evacuado poder causar danos em equipamentos e em processos de fabricac o Medidas a serem tomadas Uma descarga perfeita do condensado otimiza diretamente a qualidade do ar comprimido Para evitar danos e falhas favor observar sem falta Observa o precisa da utiliza o de acordo com a finalidade e dos par metros operacionais do BEKOMAT em liga o com o caso de utiliza o ver a este respeito o cap tulo Utiliza
27. conductors If the potential free contact carries voltage that is dangerous in the case of contact a corresponding separator must also be provided The provided 24 VDC voltage must meet the requirements for protective extra low voltages PELV in accordance with IEC 60364 4 41 D Note Between terminals KL 1 1 and 1 3 of the VCD devices and housings or condensate connections there is no galvanic isolation As regards tests for example protective conductor tests in accordance with VDE 0701 0702 IEC 85 361 CD it must be ob served that there is only a connection for the establishment of a functional earthing between the touchable conductive parts of the device and the protective conductor base and no protective connection capable of carrying current Tighten the threaded cable connection with a slightly sealing effect Potential free contact Via the potential free contact the alarm signal can be transmitted i e to a control system The switch over contact can be operated in the fail safe mode For example if supply voltage is applied and if the D130 functions trouble free the alarm relay is activated The normally open contact 0 7 0 8 is closed If no supply voltage is applied or if a trouble indication occurs the alarm relay is released The normally open contact is open alarm External test button optional With this button accumulated condensate can be discharged systematically via remote control Here the n
28. de potencial segundo VDE 0100 IEC 60364 D130 25 Electrical installation Instalaci n el ctrica Installation electrique Instala o el trica english VAC voltages 0 8 normally open 07 common gt normally closed 0 2 PE Earth Ground 0 1 N Neutral 0 0 L Phase 24 VDC voltage normally open common normally closed 24 VDC 0V E 0 7 D 24V 24V OV 24 VDC It is imperative to read the permissible mains voltage from the type plate G Carry out installation works in accor dance with VDE 0100 IEC 60364 Do not install when voltage is applied Lift off domed cover A after removing the 4 screws B Take power supply board C out of the domed cover A after removing the screw D Guide cables for power supply E and potential free contact F through screwed cable fittings Terminals VAC power supply 0 0 L 0 1 N 0 2 PE 24 VDC power supply 24 VDC 0V OV 24 VDC In the case of 24 VDC operation do not connect 24 VDC to frame because the internal housing potential of the device is negative The provided 24 VDC voltage mustmeet the requirements for protective extra low voltages PELV in accordance with IEC 60364 4 41 Connect potential free contact F to terminals 0 6 0 7 fail safe or 0 7 0 8 open during malfunction
29. densat D s que le D130 est vide la conduite d vacuation est nouveau referm e avec une parfaite tanch it avant m me que l air comprim ne puisse s chapper O condensado corre atrav s do tubo adu tor 1 para dentro do D130 e acumulase no interior da caixa 2 Um sensor que trabalha capacitivamente 3 vai continu amente registando o nivel transmitindo um sinal ao comando electr nico logo que o dep sito se encher de conden sado A v lvula de comando piloto 4 accionada e o diafragma 5 abre o tubo de descarga 6 para escoamento do condensado Esvaziado o D130 o tubo de descarga de novo fechado hermeticamente a tempo para evitar perdas desnecess rias de ar comprimido En funcionamiento El aparato est bajo tensi n el ctrica Procesode purga La salida est abierta Perturbaci n El modo ALARMA est ectivado Test Purga manual alarma 06000 El interruptor de TEST sirve para Pr t fonctionner Tension d alimentation pr sente O o O Q La touche Test sert tester le Phase de purge Conduite d vacuation ouverte Dysfonctionnement Mode Alarme activ Test Purge manuelle Alarme Estado de prontid o para entrar em funcionamento Tens o aplicada O o O Q O bot o de teste utilizado para Processo de descarga Tubo de descarga est aberto Avaria Modo de alarme est activado Teste Drenagem manual alarme el control del funcio
30. duite d coulement doit tre raccord e par un col de cygne sur la conduite collectrice 1 Di metro m nimo do tubo e acess rios adutor 24 di metro interno 18 mm N o montar filtros no tubo adutor Declive de aflu ncia gt 1 S utilizar v lvulas esf ricas Press o no m nimo 0 8 ou 1 2 bar Ver press o indicada na placa indi cadora das caracter sticas Tubo flex vel curto 7 Por cada metro de subida no tubo de descarga a press o m nima neces s ria vai aumentando em 0 1 bar O tubo de descarga n o deve exceder 5 m de subida 8 Assentar tubagem colectora com di metro m nimo de 1 e 1 de declive 9 Emcaso de problemas de aflu ncia instalar um tubo de evacuac o do ar oak N o Observe diferencial de presi n Se tiene que purgar por separado cada punto de purga Important diff rences de pression Chaque point de soutirage de condensat doit tre purg individuellement pour viter le by pass Une purge continue ne serait plus possible dans ces conditions Importante diferencas de press o Cada fonte de condensado ter que ser drenada separadamente Observe compensaci n Si no hay suficiente pendiente descen dente constante en la tuber a de la ent rada se tiene que montar una tuber a de Important quilibrage d air Si la pente de l amen e n est pas suffisante il faut poser une conduite d quilibrage d air Important
31. e evacua o do ar Se o declive da aflu ncia nao for suficiente ou se houver outros pro blemas de aflu ncia deve montar se compensacion um tubo de ventila o Observe Important Importante separacion de los condensados chicane desvio Si se quiere purgar una tuber a es mejor si se realiza una desviaci n de la corri ente de aire comprimido Sila purge doit s effectuer directement sur la tuyauterie il faut pr voir une chicane pour quele condensatne soit pas entrain par le d bit d air comprim Quando se pretende efectuar a drenagem directamente atrav s da tubagem deve se prever um desvio para a corrente de ar D130 19 Installation Instalaci n lish Installation Instala o bii a wrong no correcto correct correcto incorrect incorrecto correct correcto Note Continuous slope The feed line must always be laid with a continuous downward slope If the space for installation is too restricted the lower JI feed line must be provided with a sepa 7 gt LE AENA ENNAN NNNNNNNNNNNNNNNNNNNNANNNAN fL HI rate venting line Sooo Note Venting line In the case of large condensate quanti ties it will always be necessary to install a separate venting line INN Man Note Continuous slope Itis importantto avoid w
32. e du D130 selon les indications de ce manuel d utilisation o Remarque Respectez imp rativement toutes les informations relatives un danger ou un avertissement Respectez galement toutes les prescriptions et consignes de s curit relatives la protection des travailleurs et la protec tion incendie en vigueur au lieu d installation en question Utilisez toujours l outillage et le mat riel appropri s et en bon tat N utilisez aucun produit de nettoyage agressif ni d appareils inadapt s par exemple les nettoyeurs haute pression Notez bien que les condensats peuvent contenir des composants agressifs et n fastes pour la sant C est pourquoi il est recommand d viter tout contact avec la peau Les condensats sont soumis la r glementation sur les d chets Ils doivent tre collect s dans des r cipients appropri s limin s ou recycl s 16 D130 Instala o Perigo Ar comprimido O contato com ar comprimido escapando r pida ou repentinamente ou pecas que rebentam e ou que nao est o fixadas podem provocar ferimentos graves ou a morte Medidas a serem tomadas N o ultrapassar a press o m xima de servi o ver placa de caracter sticas Trabalhos de manuten o s devem ser executados com o sistema despressurizado S usar material de instala o prova de press o Montar de modo fixo a tubula o de admiss o Tubula o de descarga mangueira de press o cur
33. efectuosa la v lvula de pilotaje est defectuosa controle la tuber as cambie las piezas de desgaste compruebe si puede oir la v lvula actuando pulse el interruptor TEST varias veces compruebe la tensi n de 24 VCC del circuito de pilotaje en los bornes 1 0 1 1 sin carga hasta 36 VCC Origines possibles Conduites d arriv e et ou d vacuation obtur es ou bouch es Usure Carte de commande d fectueuse Electrovanne d fectueuse Contr ler l arriv e et l vacuation Remplacer les pi ces d usure V rifier si l ouverture de la soupape est perceptible Presser plusieurs fois la touche Test V rifier les 24 VDC sur la carte de commande aux bornes 3 0 3 1 3 2 mesurable sans charge jusqu 36 VDC Causas poss veis tubo de aflu ncia e ou descarga fecha do ou entupido desgaste placa de comando defeituosa v lvula magn tica defeituosa controlar tubos de aflu ncia e descar ga substituir pe as de desgaste verificar se a v lvula se abre audivel mente premir repetidamente o bot o de teste verificar tens o 24 VDC dos bornes 3 0 3 1 3 2 na placa de comando sem carga pode ser medida at 36 VDC Posibles causas la tuber a de la entrada no tiene pen diente descendente constante hay demasiada cantidad de conden sado el sensor est muy sucio la red no tiene la presi n m nima instale la tuber a con pendiente des cendente con
34. effect on the safety of the subsequent processes and may prevent damage to persons and plants Itis the task of the operator to ensure that the indicated conditions are met during the entire operating time For the employment in CO plants a D130 with a CO specification D130 CO must be used The D130 and the condensate supply line need to be protected against frost as otherwise the function cannot be guaranteed Donaldson also offers suitable products for this purpose The additional control allows the user to externally actuate the D130 valve with a 24 V control voltage relay K1 and to moni tor the valve switching cycles via a potential free contact relay K2 Exclusion from the field of application The D130 as a condensate drain alone cannot guarantee a defined compressed air quality for this purpose other additional technical devices are required D130 is not suitable for use in plants carrying vacuum or atmospheric ambient pressure or in hazardous areas The D130 must not be exposed to permanent direct solar or thermal radiation D130 must not be installed and operated in areas with an aggressive atmosphere D130 Indicaciones de seguridad Por favor compruebe que este manual de instrucciones corresponde realmente a su maquina AR Tenga en cuenta todas las indicaciones facilitadas en este manual Contiene informaci n b sica importante para la instalaci n el funcionamiento y el mantenimiento
35. ensor 3 continuously registers the liq uid level and passes a signal to the elec tronic control as soon as the container is filled The pilot valve 4 is then activated and the diaphragm 5 opens the outlet line 6 for discharging the condensate When the D130 unit has been emptied the outlet line is closed again quickly and tightly without wasting compressed air Q Ready for operation Voltage is being applied Discharge procedure Outlet line is open Malfunction Alarm mode is activated Test Manual drainage alarm 6 6 The test button is used for checking correct functioning Pressing Effect Short Manual drainage gt 1 min Alarm mode Switching sequence of valve in alarm mode Secuencia de actuaci n de la valvula en el modo de alarma S quence d activation de la vanne en mode Alarme Sequ ncia de liga o da valvula no modo de alarme 7 5 sec 1 min 3 min 4 min 4 min MEM Alarm signal via potential free contact Mensaje de alarma a trav s de contacto sin potencial Signal d alarme d livr sur le contact sans potentiel Sinal de alarme via contacto isento de potencial When the microcontroller registers a malfunction the device will automatically change to the alarm mode The switching sequence of the valve see illustration continues until the fault is cleared auto matically or through maintenance The red LED flashes a
36. ficient maintenance the D130 can malfunction Condensate which is not discharged can lead to damage to plants and in manufacturing processes Measures Fail safe condensate discharge directly optimises the compressed air quality To prevent damage and failures it is imperative To comply with the provisions regarding proper use and with the operating parameters of the D130 in connection with the case of application see chapter Proper use To strictly adhere to the installation and operating advice in these instructions To maintain and check the D130 at regular intervals in accordance with the advice in these operating instructions o Note It is imperative to observe all hazard statements and warnings listed here Please also observe all regulations and notes regarding the industrial safety and fire prevention at the respective place of installation As a matter of principle only use suitable and appropriate tools and materials in a proper condition Do not use aggressive cleaners and improper devices such as high pressure cleaners Please note that condensates may contain aggressive or harmful components Therefore skin contact should be avoided Condensate is subject to mandatory waste disposal and must be collected in suitable containers and disposed of or processed properly 28 D130 Control y mantenimiento iPeligro A jAire comprimido Un golpe de aire comprimido que escapa repentinamente o
37. final ou tratado D130 31 Maintenance Mantenimiento Entretien Manuten o english Maintenance recommendation Housing and valve should be cleaned once a year Replace wearing parts once a year Set of wearing parts D130 x Functional test of D130 device Briefly press test button 2 sec Valve opens for condensate discharge Checking of alarm signal Shut off condensate inflow Press test button for at least 1 minute Red LED flashes after 1 minute Alarm signal is being relayed 32 D130 espa ol fran ais portugu s Recomendaciones para el mantenimiento anualmente limpie la carcasa y la v l vula anualmente cambie los elementos de desgaste Kit de piezas de desgaste D130 x Recommandations pour l entretien 1 fois par an nettoyer le bo tier et la soupape 1 fois par an remplacer les pi ces d usure Kit de pi ces d usure D130 x Recomendac o de manutenc o limpar todos os anos a caixa e a v l vula limpar todos os anos a caixa e a v l vula Jogo de pecas de desgaste D130 x Control del funcionamiento del D130 Accione el pulsador de TEST durante unos segundos La v lvula abre para la evacuaci n del condensado Control del mensaje de alarma cierre la entrada de los condensados accione el pulsador de TEST durante 1 minuto el LED
38. idad del aire comprimido de manera directa Tenga en cuenta los puntos siguientes para prevenir da os y paradas en la producci n Respeto del uso apropiado y de los par metros de servicio del D130 teniendo en cuenta el campo de aplicaci n de cada caso v ase cap tulo Uso apropiado Observaci n estricta de las indicaciones de instalaci n y servicio facilitadas en este manual Mantenimiento regular y control del D130 acorde a las indicaciones del manual e Atenci n Tenga siempre en cuenta todas las indicaciones de peligro y advertencia facilitadas Observe igualmente todas las normativas e indicaciones de protecci n en el trabajo y contra incendios all donde se efect e la instalaci n Utilice nicamente herramientas y materiales adecuados y en buen estado No utilice detergentes agresivos ni herramientas inadecuadas como limpiadores a alta presi n Tenga en cuenta que el condensado puede contener componentes agresivos y da inos para la salud Por esa raz n deber evitarse siempre el contacto con la piel El condensado es un residuo que el usuario est obligado a gestionar correctamente recogi ndolo en recipientes adecuados para luego eliminarlo o tratarlo D130 29 Contr le et maintenance Danger Air comprim Tout contact avec de l air comprim s chappant rapidement ou de fa on brutale ou tout contact avec des parties de l installation pr sentant un risque d clatement peut ca
39. itar que personas u objetos puedan ser alcanzados por escapes de aire comprimido Peligro Corriente el ctrica El contacto con componentes sometidos a tensi n y sin aislamiento acarrea peligro de sufrir descargas el ctricas que deriven en heridas o muerte Medidas preventivas Al realizar la instalaci n el ctrica respete todas las normativas vigentes por ejemplo la VDE 0100 IEC 60364 Realice siempre los trabajos de mantenimiento con la m quina desconectada de la red el ctrica Los trabajos el ctricos deber n dejarse en manos de personal autorizado y cualificado Otras indicaciones de seguridad Durante la instalaci n y el funcionamiento deber n respetarse igualmente las normativas nacionales de seguridad vigentes No utilizar el D130 en zonas con peligro de explosi n Evite los momentos de apriete excesivos al atornillar las conducciones de alimentaci n Esto deber tenerse en cuenta es pecialmente en el caso de atornilladuras c nicas El D130 s lo podr funcionar con corriente No utilizar la tecla de test para la evacuaci n continua de agua Utilice exclusivamente recambios originales S lo as quedar garantizado el buen funcionamiento del aparato Indicaciones adicionales Para el montaje de la alimentaci n use llaves SW36 para sujetar D130 Precauci n N iMal funcionamiento Una instalaci n incorrecta y la falta de mantenimiento pueden provocar que el D130 fu
40. m AC 1 A fusion lente prescrit DC 1 A fusion lente recom para AC 1 A lenta prescrito para DC 1 A lenta Recommanded cable jacket diameter Secci n recomendada de la cubierta del cable Diam tre recommand pour la gaine du c ble Di metro recomendado do inv lucro do cabo 5 8 8 5 mm 0 23 0 34 recommended wire cross section Secci n recomendada del conductor Section recommand e pour les conducteurs Se o recomendada do condutor 3X 0 75 1 5 mm 0 03 0 06 inches squared recommended stripping of cable jacket Retirada recomendada de la cubierta del cable Longueur recommand e pour le d nudage de la gaine du c ble Assentamento recomendado do inv lucro do cabo PE ca 60 mm L N ca 50 mm recommended wire stripping Longitud recomendada de la virola del cable Longueur recommand e pour le d nudage Comprimento recomendado do inv lucro do condutor 6 mm 0 24 inch Connection data of the potential free contact Switch to load Datos de conexi n del contacto libre de potencial Conmutaci n carga Caract ristiques de raccordement du contact sans potentiel Commuter une charge Dados de conex o do contato livre de potencial conectar carga AC max 250 V 1A DC max 30 V 1A Connection data of the potential free contact Switch to low signal Datos de conexi n del contacto libre de potencial Conmutaci n se al d bil Caract ristiques de racc
41. m conter elementos agressivos e nocivos sa de Por isso evitar qualquer contato com a pele Condensado um res duo sujeito destina o final que dever ser recolhido em recipientes apropriados levado destina o final ou tratado D130 17 Installation Instalaci n Installation Instala o english wrong no correcto incorrect incorrecto correct correcto correct correcto 1 Feed pipe and fitting at least 3 4 internal dia gt 0 71 inch 2 No filters in feed line 3 Slope in feed line gt 1 4 Only use ball valves with full open port 5 Pressure min 12 psig or 18 psig check type plate for correct pres sure 6 Short pressure hose 7 For each yard of rising slope in the outletline the required minimum pres sure will increase by 1 5 psig The rise of the outlet line must not exceed 17 feet 8 Collecting line min 1 with 196 slope 9 In the case of inflow problems install venting line Note Pressure differences Each condensate source must be drained separately Note Venting MODO If the feed line cannot be laid with suffici ent slope it will be necessary to install a venting line Note Deflector area If drainage is to take place directly from a line it is
42. nacionais Ter a certeza que o D130 s ir funcionar no mbitos dos valores limite indicados na placa de caracter sticas Do contr rio existe perigo para pessoas e materiais podendo ocorrer falhas de funcionamento e operacionais No caso de d vidas ou de quest es relacionadas com as presentes instru es de instala o e opera o favor entrar em contato com a Donaldson Perigo N Ar comprimido O contato com ar comprimido escapando r pida ou repentinamente ou pecas que rebentam e ou que n o est o fixadas podem provocar ferimentos graves ou a mort Medidas a serem tomadas N o ultrapassar a press o m xima de servi o ver placa de caracter sticas Trabalhos de manuten o s devem ser executados com o sistema despressurizado S usar material de instala o prova de press o Montar de modo fixo a tubula o de admiss o Tubula o de descarga mangueira de press o curta e ligada a um tubo a prova de press o Impedir que pessoas ou objetos possam ser atingidos pelo condensado ou pelo ar comprimido que escapa Perigo Tens o da rede Devido ao contato com pecas n o isoladas e condutoras da tens o de rede existe o perigo de choque el trico com ferimentos e morte Medidas a serem tomadas Na instala o el trica dever o ser observadas todas as diretiva vigentes p ex VDE 0100 IEC 60364 Trabalhos de manuten o s devem ser executados com o sistema desenergizado Todos os tra
43. namiento fonctionnement controlar o funcionamento Accionamiento Resultado Action Effet Accionamento Efeito r pido purga manual br ve Purge manuelle r pido drenagem manual gt 1 min modo de alarma gt 1 min Mode Alarme gt 1 min modo de alarme Si el microcontrolador detecta una perturbaci n en el funcionamiento se activa el modo de alarma La secuencia de actuaci n de la v lvula dura hasta que la causa de la perturbaci n haya sido eliminada por si misma o por un mantenimiento El LED rojo parpadea durante el estado de alarma Posibles causas son p ej fallos en el montaje la presi n est por debajo de la presi n m nima indicada a cantidad de condensado es dema siado alta est taponada o cerrada la tuber a de la salida cantidad extrema de part culas de suciedad tuber as heladas Si la perturbaci n no est eliminada dentro del primer minuto se activa el mensaje de la alarma ver im gen que puede ser transmitida como se al sin potencial a trav s del rel de alarma Lorsque le microcontr leur d tecte une anomalie il active le mode alarme La s quence d activation de la vanne voir figure persiste jusqu ce que le probl me soit r solu automatiquement ou par intervention de maintenance La LED rouge clignote pendant la fonction d alarme Causes de dysfonctionnement possibles D faut au niveau de l installation Pre
44. ncial de la carcasa Latensi n disponible de 24 VDC deber cumplir los requisitos para las bajas tensiones de funcionamiento con ais lamiento seguro PELV previstos en la IEC 60364 4 41 Conectar el contacto libre de potencial F a los bornes 0 6 0 7 cerrado en caso de averia o 0 7 0 8 abierto en caso de averia Tensar el cable E F y apretar las atornilladuras Colocar la platina de la fuente de ali mentaci n C en la tapa de la carcasa A apretando el tornillo D Introducir la clavija del cable H en la platina de control K Sise han extra do por error los cordones de la clavija el orden para volver a conectarlos ser el siguiente 1 0 marr n 1 1 azul 2 0 negro Colocar la tapa de la carcasa A y apretara continuaci n los 4 tornillos B Atenci n La platina de la fuente de alimentaci n C se coloca invertida cabeza abajo en la tapa de la carcasa A En funcionamiento sin carga se medir en los bornes 1 0 y 1 1 clavija del cable H una tensi n de hasta 36 VDC Respecter imp rativement la tension secteur admissible mentionn e sur la plaque signal tique G R aliserles travaux d installation confor m ment VDE 0100 IEC 60364 Ne pas effectuer l installation SOUS TENSION D monter le capot A apr s avoir d viss les 4 vis B Retirer la carte d alimentation C du capot A apr s avoir d viss la vis D Enfiler a travers le
45. ncione mal El condensado no evacuado puede provocar da os en las instalaciones y en los procesos de producci n Medidas preventivas Una evacuaci n segura del condensado optimiza la calidad del aire comprimido de manera directa Tenga en cuenta los puntos siguientes para prevenir da os y paradas en la producci n Respeto del uso apropiado y de los par metros de servicio del D130 teniendo en cuenta el campo de aplicaci n de cada caso v ase cap tulo Uso apropiado Observaci n estricta de las indicaciones de instalaci n y servicio facilitadas en este manual Mantenimiento regular y control del D130 acorde a las indicaciones del manual Uso apropiado El D130 es un purgador de condensados regulado electr nicamente seg n el nivel para instalaciones de aire comprimido Su funcionamiento deber producirse siempre teniendo en cuenta los par metros de servicio ver datos t cnicos El D130 es capaz de evacuar el condensado bajo presi n de servicio y sin producir apenas p rdidas de presi n El D130 14 necesita para su funcionamiento una corriente y una presi n concretas ver datos t cnicos En aquellas aplicaciones en las que se exige un nivel de calidad de aire comprimido m s alto industria de la alimentaci n t cnica m dica laboratorios procesos especiales etc el usuario deber tomar medidas para la vigilancia de dicha calidad Esas medidas influyen en la seguridad de los procesos sucesivos y p
46. nte aux processus de fabrication Mesures pr ventives Le bon fonctionnement de la purge des condensats permet une optimisation directe de la qualit de l air comprim Pour viter tout endommagement et tout arr t de production il est imp ratif de respecter les consignes suivantes Respecter scrupuleusement les instructions pour une utilisation conforme l usage pr vu et les param tres de fonctionnement du D130 dans le contexte de son utilisation consulter cet effet le chapitre Utilisation conforme a l usage pr vu Respecter scrupuleusement toutes les instructions d installation et d utilisation communiqu es dans cette notice Respecter scrupuleusement la p riodicit de maintenance et de contr le du D130 selon les indications de ce manuel d utilisation Eb Remarque Respectez imp rativement toutes les informations relatives un danger ou un avertissement Respectez galement toutes les prescriptions et consignes de s curit relatives la protection des travailleurs et la protec tion incendie en vigueur au lieu d installation en question Utilisez toujours l outillage et le mat riel appropri s et en bon tat N utilisez aucun produit de nettoyage agressif ni d appareils inadapt s par exemple les nettoyeurs haute pression Notez bien que les condensats peuvent contenir des composants agressifs et n fastes pour la sant C est pourquoi il est recommand d viter tout contact avec l
47. o os 4 parafusos B Aten o A placa da fonte de alimenta o C est alojada na tampa de cobertura A de cabe a para baixo Em opera o sem carga nos bornes 1 0 e 1 1 terminal de cabos H pode ser medida uma tens o de at 36 VDC D130 27 Supervision and maintenance Danger Compressed air Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or through bursting plant components or plant components which are not secured Measures Do not exceed the maximum operating pressure see type plate Only carry out service measures when the system is pressureless Use pressure resistant installation material only The feed pipe must be tubed firmly Discharge pipe short fixed pressure hose onto pressure resistant pipe Make sure that persons or objects cannot be hit by condensate or escaping compressed air Danger Supply voltage There is the risk of an electric shock involving injury or death when coming into contact with non insulated components carrying supply voltage Measures During electric installations all regulations in force need to be adhered to e g VDE 0100 IEC 60364 Service measures must only be undertaken when the system is deactivated All types of electrical work must be carried out by authorised and qualified personnel only Caution A Malfunctions in the application Through incorrect installation and insuf
48. on la norme IEC 60364 4 41 db Remarque Entre les bornes KL1 1 1 3 des appareils VDC et le corps ou les raccords des conduites de condensat il n y a pas d isola tion galvanique Lors des v rifications par ex les tests du conducteur de protection selon VDE 0701 0702 IEC 85 361 CD il faut veiller ce que entre les l ments conducteurs et accessibles de l appareil et le point d appui du conducteur de protection il n y ait qu une liaison permettant de r aliser une mise la terre fonctionnelle et non une liaison de protection capable de v hiculer un courant Serrer l g rement le presse toupe de facon assurer l tanch it Contact sans potentiel Le contact sans potentiel peut tre utilis pour r aliser un report d alarme par exemple vers un syst me de supervision ou de t l surveillance Le contact inverseur peut tre exploit par exemple en mode fail safe s curit positive Si la tension de service est pr sente et si le D130 fonctionne normalement le relais d alarme est excit Le contact de travail 7 8 est ferm Si la tension d alimentation n est pas pr sente ou si un signal d alarme est mis le relais d alarme est d sexcit Le contact de travail est ouvert Alarme Bouton Test externe en option Celui ci permet de commander distance au moment voulu la purge du condensat collect La fonction normale du bouton Test est ainsi report e du D130 vers un contact externe Lo
49. onctionnement admissibles voir caract ristiques techniques Le D130 permet d vacuer le condensat du r seau de distribution sous pression pression de service et ce pratiquement sans perte de charge Pour son fonctionnement le D130 requiert une tension d alimentation lectrique et une pression de service voir caract ris tiques techniques Lors d une utilisation dans des installations soumises des exigences plus pouss es quant la qualit de l air comprim industrie alimentaire techniques m dicales quipements de laboratoires processus sp ciaux etc l exploitant est tenu de prendre des mesures pour la surveillance de la qualit de l air comprim Ces mesures ont une influence directe sur la s curit des processus en aval et permettent ainsi d viter les dommages corporels et l endommagement des installations Ilincombe l exploitant d assurer les conditions mentionn es pendant toute la dur e de service Pour les installations de CO il faut imp rativement utiliser un D130 en version CO D130 CO Le D130 et la conduite d amen e du condensat doivent tre prot g s contre le gel sinon le fonctionnement n est pas assur Donaldson propose galement des produits ad quats cet effet La commande suppl mentaire permet l utilisateur de r aliser une commande externe pour l lectrovanne du D130 l aide une tension lectrique de commande de 24 V Relais K1 ainsi que la surveillance des
50. ordement du contact sans potentiel Commuter un petit signal Dados de conex o do contato livre de potencial conectar sinal pequeno min 5 VDC 10 mA Protection class Tipo de protecci n Degr de protection Classe de prote o IP 65 VAC V alternating current VDC V direct current la conmutaci n de se ales d biles de petits signaux pequenos The switching of loads has the result that the properties of the contact are no longer suitable for the switching of low signals VAC V alternating current corriente alterna VDC V direct current corriente continua La conmutaci n de cargas tiene como consecuencia que las caracter sticas del contacto ya no sean las adecuadas para VAC V alternating current Tension alternative VDC V direct current Tension continue La commutation de charges a pour cons quence que les propri t s du contact ne conviennent plus pour la commutation VAC V alternating current tens o alternada VDC V direct current tens o cont nua a conex o de cargas faz com que as caracter sticas do contato deixem de ser apropriadas para a conex o de sinais D130 11 Function Funcionamiento Functionnement Funcionamento english The condensate flows through the feed line 1 into the D130 unit and accumu lates in the container 2 A capacitive s
51. ormal test button func tion is additionally led out of the D130 When the external contact is closed the valve opens Observe the additional instructions Between the protective conductor PE connection and the piping a potential difference is not admissible If required potential equalisation in accordance with VDE 0100 IEC 60364 must be provided for 22 D130 Instalaci n el ctrica iPeligro iCorriente el ctrica El contacto con componentes sometidos a tensi n y sin aislamiento acarrea peligro de sufrir descargas el ctricas que deriven en heridas o muerte Medidas preventivas Al realizar la instalaci n el ctrica respete todas las normativas vigentes por ejemplo la VDE 0100 IEC 60364 Realice siempre los trabajos de mantenimiento con la m quina desconectada de la red el ctrica Los trabajos el ctricos deber n dejarse en manos de personal autorizado y cualificado Si la alimentaci n es por AC deber disponerse cerca un dispositivo de separaci n accesible por ejemplo una clavija de enchufe o un interruptor que a sle todas las conducciones el ctricas e Si el contacto libre de potencial es atravesado por tensiones que supongan un riesgo ante contactos fortuitos de ber instalarse el dispositivo de aislamiento que convenga La tensi n disponible de 24 VDC deber cumplir los requisitos para las bajas tensiones de funcionamiento con aislamiento seguro PELV previstos en la IEC 60
52. perating pressure see type plate Only carry out service measures when the system is pressureless Use pressure resistant installation material only The feed pipe must be tubed firmly Discharge pipe short fixed pressure hose onto pressure resistant pipe Make sure that persons or objects cannot be hit by condensate or escaping compressed air Danger A Supply voltage There is the risk of an electric shock involving injury or death when coming into contact with non insulated components carrying supply voltage Measures During electric installations all regulations in force need to be adhered to e g VDE 0100 IEC 60364 Service measures must only be undertaken when the system is deactivated All types of electrical work must be carried out by authorised and qualified personnel only Further safety advice For installation and operation the national regulations and safety codes in force must also be adhered to Do not use the D130 in hazardous areas Regarding the inlet screw joints excessive tightening forces must be avoided This applies in particular to conical screw joints The D130 will only function when voltage is applied Do not use the test button for permanent drainage Only use genuine spare parts This is imperative to ensure perfect functioning Additional advice During installation use the spanner flat at the feed pipe width across flat 36 as a back rest D130
53. pliquant le m me niveau d exigences en mati re de tests Este produto foi testado de acordo com os requisitos da CAN CSA C22 n 61010 1 segunda edic o com incorpora o do aditamento 1 ou de uma vers o posterior da mesma norma levando em consi derac o o mesmo n vel de requisitos de teste Operating pressure min max Presi n de servicio min max Pression de service min max Press o de servico min max 12 230 psig min max temperature Temperatura min max Temp rature min max Temperatura min max 34 140 F Condensate feed Entrada condensado Descarga do condensado mangueira 3 8 Entr e du condensat 3 ANRT Alimenta o de condensado Condensate discharge hose Salida de condensado manguera 1 2 Sortie du condensat flexible dia 1 2 Peso vacio Poids vide Peso vazio Condensate oil contaminated oil free not aggressiv Condensado oleoso exento de aceite no agresiva Condensat huileux non huileux pas agressif Condensado com leo isento de leo nao agressivo Housing Aluminum KTL coated Carcasa Aluminum beschichted Corps Aluminium recouvert Gabinete Aluminio beschichted Weight empty 6 4 lbs Max performance for the blue climatic zone see also Chapter Climatic zone and performance data Capacidad max para zona clim tica azul ver tambi n capitulo Zonas clim ticas y datos de capacidad Capacit
54. portant Importante pendiente descendente constante Si se emplea como entrada un tubo fle xible se tiene que evitar que se forme un sif n pente continue Si l amen e est r alis e au moyen d un flexible il faut viter toute retenue d eau declive continuo Quando se utiliza um tubo flexivel de ar comprimido para a aflu ncia do conden sado deve evitarse bolsas de agua Observe pendiente descendente constante Si se emplea como entrada un tubo rigido se tiene que evitar que se forme un sif n Important pente continue Si l amen e est r alis e au moyen d une tuyauterie rigide il faut aussi viter toute retenue d eau Importante declive continuo Evitar igualmente bolsas de agua quando se assenta tubos para a aflu ncia D130 21 Electrical Installation Danger N Supply voltage There is the risk of an electric shock involving injury or death when coming into contact with non insulated components carrying supply voltage Measures During electric installations all regulations in force need to be adhered to e g VDE 0100 IEC 60364 Service measures must only be undertaken when the system is deactivated All types of electrical work must be carried out by authorised and qualified personnel only Atan AC supply a reliably accessible separator must be provided close by e g power plug or switch which separates all current carrying
55. r o ser protegidos contra a geada do contr rio n o fica assegurada a funcionalidade Para essa finalidade a Donaldson oferece produtos adequados Exclus o do campo de aplica o O D130 como condutor de descarga de condensado n o pode por si s garantir uma qualidade definida de ar comprimido pois para isso s o ainda necess rios outros dispositivos t cnicos O D130 n o apropriado para utiliza o com v cuo ou em equipamentos conduzindo press o atmosf rica ambiente ou em reas com perigo de explos o O D130 n o pode estar exposto permanente incid ncia direta dos raios solares ou do calor O D130 n o pode ser instalado nem funcionar em reas com uma atmosfera agressiva D130 Technical Data Datos t cnicos Caract ristiques Dados t cnicos This product has been tested to the requirements of CAN CSA C22 2 No 61010 1 second edition including Amendment 1 or a later version of the same standard incorporation the same level of testing requirements Este producto se ha sometido a pruebas acorde a las exigencias de la CAN CSA C22 2 n 61010 1 segunda edici n incluyendo el suplemento 1 o una versi n posterior de la misma norma conservan do siempre el mismo nivel de exigencia con respecto a las pruebas Ce produit a t test selon les exigences de la norme CAN CSA C22 2 n 61010 1 deuxi me dition en tenant compte du compl ment 1 ou d une version plus r cente de la m me norme en ap
56. rsque ce contact est ferm la vanne s ouvre Suivre les instructions de la notice s par e Aucune diff rence de potentiel n est admissible entre la borne PE du conducteur de protection et le r seau de conduites Le cas ch ant il faut pr voir une liaison quipotentielle selon VDE 0100 IEC 60364 24 D130 Instala o el trica Perigo Tens o de rede Devido ao contato com pecas n o isoladas e condutoras da tens o de rede existe o perigo de choque el trico com ferimentos e morte Medidas a serem tomadas Na instala o el trica dever o ser observadas todas as diretiva vigentes p ex VDE 0100 IEC 60364 Trabalhos de manuten o s devem ser executados com o sistema desenergizado Todos os trabalhos el tricos s poder o ser efetuados por pessoal especializado e autorizado No caso de alimenta o por AC nas proximidades deve ser previsto um dispositivo de corte acess vel por ex ficha de rede ou interruptor que possa cortar todos os condutores que conduzam corrente Seo contato livre der potencial conduzir tens es perigosas ao toque tamb m aqui dever ser previsto um dispo sitivo de corte correspondente Atens o dispon vel de 24 VDC dever atender os requisitos de baixas tens es funcionais com corte seguro PELV segundo IEC 60364 4 41 o Observa o Entre os terminais KL 1 1 1 3 dos aparelhos VDC e o gabinete ou conex es de condensado nao existe qualquer
57. s long as the device is in the alarm mode Malfunctioning could be caused by e g Mistakes during installation Dropping below the necessary mini mum pressure Excessive condensate quantities over loading Blocked shut off outlet line Extreme amount of dirt particles Frozen piping If the fault is not cleared within the first minute a fault signal is triggered see illustration which can be picked off as a potential free signal via the alarm relay 12 D130 espa ol fran ais portugu s El condensado fluye a trav s de la tube ria de entrada 1 al D130 y se acumula en el dep sito 2 El sensor capacitivo de nivel 3 controla permanentemente el nivel de llenado Si el dep sito est lleno el sensor emite una se al a la unidad de pilotaje electr nico Inmediatamente se acciona la v lvula de pilotaje 4 y la membrana 5 abre la salida 6 para purgar el condensado En el momento en el que el D130 esta vac o se cierra la salida herm ticamente antes de que se produzca un escape de aire comprimido Amen dans le D130 par la conduite d arriv e 1 le condensat est collect dansle r servoir 2 Une sonde capacitive 3 surveille en permanence le niveau de remplissage et envoie un signal la commande lectronique d s que le r ser voir est rempli L lectrovanne pilote 4 est activ e et la membrane 5 ouvre la conduite d vacuation 6 pour l clusage du con
58. s presse toupes les c bles pour l alimentation lectrique E et le contact sans potentiel F Bornes VAC Alimentation lectrique 0 0 L 0 1 N 0 2 PE 24 VDC Alimentation lectrique 24 VDC 0V 0V 24 VDC Encasd alimentation 24 VDC la masse ne doit pas tre reli e au 24 VDC tant donn qu l int rieur de l appareil le moins est au potentiel du bo tier La tension continue de 24 VDC mise disposition doit r pondre aux exi gences pour les Tr s Basses Ten sions de Protection T B T P avec s paration s curis e par rapport a la tension secteur PELV Protection by Extra Low Voltage selon la norme IEC 60364 4 41 Raccorder le contact sans potentiel F aux bornes 0 6 0 7 ferm en cas de panne ou 0 7 0 8 ouvert en cas de panne Tendre les c bles E F puis serrer les presse toupes Revisserla carte d alimentation C avec la vis D dans le capot A Enficher le c ble en nappe connecteur H sur la carte de commande K Au cas o les diff rents fils seraient par inadvertance dissoci s de la fiche respecter la r partition suivante 1 0 marron 1 1 bleu 2 0 noir Mettre le capot A en place et visser les 4 vis B Important La carte d alimentation C est l envers dans le capot A A vide on peut relever aux bornes1 0 et 1 1 c ble en nappe connecteur H une tension pouvant atteindre 36 VDC Consultar sem falta na placa de caracteris
59. separa o galvanica No caso de testes por ex testes do condutor de prote o segundo VDE 0701 0702 IEC 85 361 CD prestar aten o ao fato de que entre as pecas tocaveis e condutoras do aparelho e o ponto de apoio do condutor de protec o s existe uma liga o para estabelecimento de um aterramento de funcionamento n o havendo qualquer liga o de prote o capaz de transportar corrente Apertar levemente a uni o roscada do cabo de modo a vedar Contato livre de potencial Atrav s do contato livre de potencial possivel transmitir o sinal de alarme p ex a um posto de comando O contato de comutac o pode ser operado p ex em modo fail safe Se estiver aplicada tens o de servico e se o D130 estiver funcionando sem problemas o rel de alarme est ativo O contato de trabalho 0 7 0 8 est fechado Se n o estiver aplicada qualquer tens o de servico ou se houver um aviso de falha o rel de alarme desopera O contato de trabalho est aberto alarme Bot o externo de teste opcional Deste modo poss vel descarregar o condensado existente mediante controle remoto A fun o normal do bot o de teste aqui executada adicionalmente a partir do D130 Se o contato externo fechar a v lvula abre Observar as instru es suplementares Entre a conex o do condutor de prote o PE e a rede de tubula o n o admiss vel qualquer diferen a de potencial Eventualmente dever ser prevista uma compensa o
60. ssion minimale non atteinte Trop de condensat surcharge Ecoulement bouch ou obtur Importantes quantit s d impuret s Conduites gel es Sila panne n est pas r solue en l espace d une minute un signal d alarme est mis voir figure Un signal sans potentiel est d livr par le relais d alarme Quando o microcontrolador verifica uma avaria o alarme activado A sequ n cia de liga o da v lvula ver imagem permanece activada at se eliminar a avaria automaticamente ou atrav s de manutenc o O LED vermelho pisca durante a fun o de alarme Causas poss veis da avaria s o p ex erro na instalac o press o inferior press o m nima admiss vel quantidade excessiva de condensado sobrecarga tubo adutor entupido passagem impe dida quantidade excessiva de part culas de sujidade tubagens geladas Se a falha nao for eliminada durante o primeiro minuto o aparelho activa o sinal de alarme ver imagem que poder ser comutado em sinal isento de potencial atrav s do rel do sinal D130 13 Installation Danger Compressed air Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or through bursting plant components or plant components which are not secured Measures Do not exceed the maximum operating pressure see type plate Only carry out service measures when the system is pressureless
61. stante instale una tuber a de compensaci n limpie el tubo del sensor asegure la presi n m nima necesaria o instale un D130 para baja presi n o para vac o Origines possibles Conduite d arriv e avec pente insuffi sante Trop de condensat produit Tube de sonde fortement encrass Pression minimale non atteinte R aliser l arriv e avec une pente Installer une conduite d quilibrage d air Nettoyer le tube de sonde Assurer la pression minimale ou ins taller un purgeur Low Pressure ou d pression Causas poss veis tubo adutor sem declive suficiente quantidade excessiva de condensa do tubo sensor extremamente sujo press o inferior press o m nima necess ria assentar tubo com declive adequado instalar um desvio para desvio do ar limpar o tubo sensor assegurar press o m nima ou instalar um escoadouro de baixa press o ou de v cuo Posibles causas los conductos de pilotaje estan obstrui dos desgaste limpie todo el m dulo de la v lvula cambie las piezas de desgaste limpie el tubo sensor Origines possibles Conduite d quilibrage d air bouch e Usure Nettoyer enti rement le module sou pape Remplacer les pi ces d usure Nettoyer le tube sonde Causas poss veis tubo de controlo de ar entupido desgaste limpar a unidade completa da v lvula substituir pecas de desgaste limpar tubo sensor
62. ta e ligada a um tubo prova de press o Impedir que pessoas ou objetos possam ser atingidos pelo condensado ou pelo ar comprimido que escapa Cuidado A Mau funcionamento na aplicac o Devido a uma instala o incorreta e a uma manutenc o insuficiente possivel que ocorra o mau funciona mento do D130 O condensado n o evacuado poder causar danos em equipamentos e em processos de fabrica o Medidas a serem tomadas Uma descarga perfeita do condensado otimiza diretamente a qualidade do ar comprimido Para evitar danos e falhas favor observar sem falta Observa o precisa da utiliza o de acordo com a finalidade e dos par metros operacionais do D130 em liga o com o caso de utiliza o ver a este respeito o cap tulo Utiliza o de acordo com a finalidade Observa o precisa das indica es sobre instala o e opera o contidas nas presentes instru es Manuten o regular e controle do D130 segundo as indica es contidas nas presentes instru es D Observa o Prestar atenc o sem falta a todas as indica es de perigo e advert ncias Observar igualmente todos os regulamentos referentes seguranca no trabalho e prote o contra inc ndios S devem ser usadas ferramentas apropriadas e materiais em perfeito estado N o utilizar produtos de limpeza agressivos nem aparelhos inadequados tais como equipamentos de limpeza a alta press o N o esquecer que os condensados pode
63. ticas G a tens o de rede admissivel Executar os trabalhos de instala o conforme VDE 0100 IEC 60364 N o instalar sob tens o Desmontar a tampa da cobertura A ap s soltar os 4 parafusos B Soltar o parafuso D e remover a placa da fonte de alimentac o C da tampa de cobertura A Os cabos para a alimenta o de tens o E e parao contatolivre de potencial F dever o passar pelas uni es roscadas de cabos Atribuic o dos terminais Alimenta o de tens o VAC 0 0 L 0 1 N 0 2 PE Alimentac o de tens o 24 VDC 24 VDC 0V OV 24 VDC No caso de opera o com 24 VDC n o pode er aplicada massa a positivo 24 VDC dado que o negativo interno do aparelho esta aplicado ao potencial do gabinete Atens o disponivel de 24 VDC dever atender os requisitos de baixas tens es funcionais com corte seguro PELV segundo IEC 60364 4 41 Ligar o contato livre de potencial F aos bornes 0 6 0 7 fechado em caso de falha ou a 0 7 0 8 aberto emcaso de falha Esticar os cabos E F e apertar as uni es roscadas para cabos Na tampa de cobertura A fixar a placa da fonte de alimenta o C mediante o parafuso D Encaixar o terminal de cabos H na placa de comando K Se porengano cada um dos condutores tiver sido desaparafusado do terminal de cabos aplica se a seguinte atribui o 1 0 marrom 1 1 azul 2 0 preto Colocar a tampa da cobertura A e apertar m
64. ueden evitar da os a personas e instalaciones Ser responsabilidad del usuario garantizar que se cumplan estas condiciones durante todo el tiempo de funcionamiento En instalaciones de CO deber n instalarse unidades D130 con la especificaci n CO D130 CO EI D130 y su conducci n de alimentaci n deber n estar protegidos contra congelaci n ya que de lo contrario no podr ga rantizarse su buen funcionamiento Donaldson le ofrece productos adecuados para este fin Campos de aplicaci n incorrectos El D130 no puede garantizar por s solo como purgador de condensados una calidad de aire comprimido concreta Para ello ser n necesarios otros equipos t cnicos El D130 i no es adecuado para su aplicaci n en el campo del vac o ni en plantas que funcionen a presi n atmosf rica ni en zonas Ex El D130 no deber exponerse a la radiaci n solar continua ni directa ni tampoco a la acci n de fuentes de calor El D130 no debe instalarse ni funcionar en zonas con atm sferas agresivas D130 Consignes de s curit Respectez toutes les consignes donn es dans ce mode d emploi Il contient des informations fondamentales res pecter lors de l installation de l utilisation et de la maintenance C est pourquoi il est imp ratif que ce mode d emploi soit lu avant l installation la mise en service et la maintenance par l installateur ainsi que par l exploitant et le person nel qualifi Le mode d emploi
65. user de graves blessures ou entra ner la mort Mesures pr ventives Ne pas d passer la pression de service maximale voir plaque signal tique D pressuriser le purgeur avant toute intervention d entretien ou de maintenance Nutiliser que du mat riel d installation r sistant la pression La conduite d amen e doit toujours tre r alis e en tuyauterie rigide et fixe Conduite d vacuation flexible de faible lon gueur fix et reli une tuyauterie tous deux r sistant la pression Veillez ce qu aucune personne ni objet ne risque d tre touch par le condensat ou l air comprim qui s chappe Danger A Tension lectrique Tout contact avec des l ments non isol s et sous tension pr sente un risque de choc lectrique pouvant provoquer des blessures ou entra ner la mort Mesures pr ventives Lors de la r alisation de l installation lectrique respecter toutes les prescriptions en vigueur p ex VDE 0100 IEC 60364 Avant toute intervention d entretien ou de maintenance mettre le purgeur HORS TENSION Toute intervention lectrique doit tre r alis e exclusivement par un personnel qualifi et habilit Prudence A Dysfonctionnements au niveau de l utilisation En cas d installation incorrecte et de maintenance insuffisante des dysfonctionnements peuvent appara tre au niveau du D130 Tout condensat non vacu risque d endommager les installations et de porter attei
Download Pdf Manuals
Related Search
Related Contents
SECUTEST SIII+. . . - GMC USS II Poly Perforated. Soluzione di trattamento Nordyne RC 92+ Furnace User Manual Untitled - Lilibiggs Loading Authority (OT-5) Internet Application User Guide Samsung 65" 3D FULL HD LED телевизор серии 8 UE65ES8000S Инструкция по использованию Copyright © All rights reserved.