Phocos CMLsolid 30

image

Contents

1. 5 LED X CML solid phocos R RERSET E x GE Ape 101 AHERERTURFRRSEN WRB aly al Or we LED E LED R E E E gt 75 25 75 lt 25 lt 10 3 LED E 2 LED 1 LED AG 1 LED BAIT 102
2. 1 5 DER 45A 12V 24V ER 18V 24V E E SpA RE TSAR Bt 100 JE E
3. CE CE 97 a mn 12V 24V
4. 25 1 H Z ce ur LED R LED amp 103 ae x LED CML 1 5S0C 114 228V 5 11 9 23 8 V 2 LVD 11 0 22 0V 1 BUZ LVD GEL AAAs
5. 1 2 3 m 10 mm 98 mar CML_soio phoco USB 99 m CMLsolid 30 ER
6. 20130624 1SO9001 CE RoHS Phocos AG Germany www phocos com 113
7. 104 DIP BUZ LVD GEL 8 8 8 LED 1 1 2 3 m 4 WE 50V 50V 15 5 31 0V 105 o nt RE s 1 2 400A 3
8. E B x LED E i D a Pe ze Bx LED TEMIA EB T gt 15 5131 0V A Leere BERRIES marae T Es e 108 e Ee I ET LED TARRE B ZS Kei BRI H ew Spe 2 LED R AS S e ne nn B X u 109 PAL 12V 24V CMLsolid 30 12 24 V 30 A 30 A 13 8 27 6 V 25 C EREE 14 4 28 8 V 25 C 0 5 h
9. CMLsolid 30 0 5m GEL AGM 12 24V 96 1 5 Ho H
10. 14 4 28 8V 25 C 2 h lt 12 3 24 6 V 14 8 29 6V 25 C 2h SALE lt 12 1 24 2V 30 15 5 31 0V 11 4 11 9 22 8 23 8 V 11 0 22 0 V 110 12 8 25 6V RER 10 5 21 0V 50V 50V 4 2 mV K per cell 10 mA 40 50 C 4 000 X ARRE ith AGM WXHXD 140x90x40 mm 420g 16 mm IP20 111 AS E d St ak Fl CMLsolid 20 0 20 40 60 80 100 120 140 160 112
11. 4 gt 200 3s USB USB 5V 800 mA Ba USB RJ11 6p4c 106 SI CMLsolid 30 1 1 SOC LVD
12. Fiche technique CMLsolid 30 CMLsolid 30 Tension du systeme 12 24V reconnaissance automatique Courant de charge maximum 30 A Courant de charge maximum 30 A Charge de maintien 13 8 27 6 V 25 C Charge principale 14 4 28 8 V 25 C 0 5 h par jour Charge forc e 14 4 V 28 8 V 25 C 2h Activation tension de la batterie lt 12 3 V 24 6 V Egalisation 14 8 V 29 6 V 25 C 2h Activation tension de la batterie lt 12 1 V 24 2V au moins 1 fois par mois Protection contre les surcharges 15 5 31 0V Protection contre la d charge profonde 11 4 11 9 22 8 23 8 V by SOC tension de coupure 11 0 22 0 V by voltage 72 Niveau de reconnexion 12 8 25 6 V Protection contre les sous tensions 10 5 21 0V Tension maximale du panneau 50V Tension maximale de la batterie 50V Compensation de la temp rature tension de charge 4 2 mV K par cellule Autoconsommation au ralenti 10mA Mise a la terre Mise a la terre positive emperature ambiante 40 50 C Altitude maximale 4000 m au dessus du niveau de la mer ype de batterie Plomb acide GEL AGM ouverte Dimensions I x h x p 140 x 90 x 40 mm Poids 420g Dimension maximale du cable 16 mm ype de protection IP20 73 Veuillez consulter le graphique de l aire de s curit SOA CMLsolid 30 SOA 160 140 120 100
13. Phocos Phocos CMLsolid 30 Solar charge controller Bedienungsanleitung User Manual Manual del usuario Manuel de l utilisateur Manual de Usu rio CID 181815512 CONTENTS Bedienungsanleitung User Manual Manual de Instrucciones Guide de l utilisateur Manual do Usu rio 1 19 20 37 38 56 57 75 76 95 96 113 Sehr geehrter Kunde Herzlichen Gl ckwun sch zum Kauf Ihres Phocos Produktes Bitte lesen Sie die Anweisungen sorgf ltig und gr ndlich durch bevor Sie das Produkt in Betrieb nehmen Ihr neuer CMLsolid 30 ist ein hochwertiges Ger t welches nach den j ngsten verf gbaren technischen Standards entwickelt wurde Es ist ausgestattet mit einer Reihe von herausragenden Eigenschaften Vollst ndiger ele Eindeutige leicht ablesbare Anzeige des Ladezustands Akustisches Signal bei Ladezustands nderung Tiefentladeschutz ladezustands oder spannungsgesteuert Ausgang zum ferngesteuerten Ein Ausschalten des Wechselrichters USB Standardanschluss f r das Laden von externen Ger ten Max 16 mm Anschlussklemmen ktronischer Schutz WICHTIGE ALLGEMEINE SICHERHEITSHINWEISE AN BITTE BEWAHREN SIE DIESE ANWEISUNGEN AUF Dieses Handbuch enth lt wichtige Anweisungen f r die Installation den Anschluss und den sicheren Betrieb des CMLsolid FEUERGEFAHR BITTE Batterietyp Bleis urel 30 LADEREGER IM ABSTAND VON 0 5 m ZUR BA
14. Courant nominele PV S 0 20 40 6 8 100 120 Courant nominele charge 74 140 160 Exclusions de responsabilite Le fabricant ne peut tre tenu responsable des dommages en particulier sur la batterie cause par une utilisation non conforme a celle prevue ou mentionn e dans ce manuel ou si les recommandations du fabricant de la batterie n ont pas t respect es Le fabricant ne peut tre tenu pour responsable si des op rations de maintenance ou de r paration ont t effectu es par des personnes non autoris es des utilisations inhabituelles des mauvaises installations ou des mauvaises conceptions du syst me Sous r serve de modifications sans pr avis Version 20130624 1S09001 Fabrique dans un des pays suivants Allemagne Chine Bolivie Inde Phocos AG Allemagne C Ro HS www phocos com 75 Prezado Cliente Obrigado por ter adquirido um produto da Phocos Por gentileza leia o manual todo cuidadosamente antes de usar o produto Este novo controlador CMLsolid 30 constitui um dispositivo de tecnologia de ponta desenvolvido conforme os padr es da t cnica mais avan ados Esta equipado com uma s rie de caracteristicas que se destacam como m Painel indicador do estado de carga claro e leg vel m Sinal ac stico quando houver mudan a no estado de carga m Fun o de desconex o por baixa tens o LVD controlada por estado de carga ou por tens o m Terminal de sa
15. Energie Alle Verbraucher berstrom Kurzschluss Verbraucher Rote LED blinkt abschalten Beheben Sie den Kurzschluss berstrom Der Laderegler schaltet die Verbraucher automatisch nach ca 1 Min wieder ein 14 Batteriespannung ist zu hoch gt 15 5 31 0 V berpr fen Sie ob fremde Energiequellen die Batterie laden Falls nicht ist der Laderegler Verbraucher haben keine defekt Energie REN E inai Batteriezuleitung oder Bitte berpr fen ai die u Batteriezuleitungen Batteriesicherung defekt g A E Sicherungen und die Batterie hochohmig R Batterie a Batterie hat Kapazit t ON verloren Rote LED Batterie austauschen Zeit wieder leuchtet entladen Batterie wird Modulleitung Unterbrechung tags ber nicht unterbrochen oder Vernolung beseitigen geladen de verpolt Gr ne LED aus p g 9 Lag z Batterie verpolt Batterie angeschlossen Rote LED Batterie richtig Verpolung anschlie en leuchtet 15 Technische Daten Bemerkung Die Spannungswerte vor und nach dem Schr gstrich gelten jeweils f r 12 V bzw 24 V Systeme Technische Daten CMLsolid 30 Systemnennspannung 12 24 V automatische Erkennung Max Ladestrom 30 A Max Laststrom 30 A Spannung Erhaltungsladung 13 8 27 6 V 25 C Spannung Hauptladung 14 4 28 8 V 25 C 0 5 Std t glich 14 4 28 8 V 25 C 2 Std Boost Lad ng Akt
16. Sollte das Ger t in ein Fahrzeug eingebaut werden dessen Batterie Minus an der Masse liegt so d rfen am Regler angeschlossene Verbraucher und das Modul keinesfalls mit der Fahrzeug Masse verbunden sein da dies den berladeschutz den Tiefentladeschutz und die elektronische berstrom Sicherung berbr ckt HINWEIS Beachten Sie die Hinweise des Batterieherstellers Unmittelbar an der Batterie sollte eine Schmelz Sicherung angebracht werden um eventuelle Kurzschl sse in den Batterieleitungen abzusichern Die Sicherung muss dem Nennstrom des Ladereglers entsprechen 45 A Inbetriebnahme des Ladereglers Selbsttest Sobald der Laderegler ber die Batterie mit Spannung versorgt wird f hrt er einen Selbsttest durch Erst dann wechselt die Anzeige in den Normalbetrieb um Systemspannung Der Laderegler stellt sich selbstst ndig auf 12 V oder 24 V Systemspannung ein Sobald die Spannung bei Inbetriebnahme 18 V berschreitet stellt sich der Laderegler auf 24 V Betrieb ein Sollte die Batteriespannung bei Inbetriebnahme nicht im normalen Bereich liegen so wird dies entsprechend angezeigt Siehe FEHLERBESCHREIBUNG Batterietyp Der Laderegler ist werkseitig f r den Betrieb mit Bleiakkumulatoren mit festem Elektrolyt GEL oder AGM Batterien eingestellt Wenn Sie einen Bleiakkumulator mit fl ssigem Elektrolyt verwenden nnen Sie die Ladecharakteristik einstellen siehe auch Einstellungen Es wird dann die Ausgleichsladung aktiviert
17. 4 28 8 V 25 C 0 5 h diariamente Carga r pida 14 4 28 8 V 25 C 2 h Activaci n voltaje bateria lt 12 3 24 6 V Ecualizaci n 14 8 29 6V 25 C 2 h Activaci n voltaje bater a lt 12 1 24 2 V al menos una vez cada 30 d as Protecci n sobrevoltaje 15 5 31 0V Protecci n de descarga profunda Tension de corte o de bloqueo 11 4 11 9 22 8 23 8 V en estado de la carga 11 0 22 0 V en voltaje 53 Nivel de reconexi n 12 8 25 6 V Protecci n subvoltaje 10 5 21 0V Voltaje m x panel 50V Voltaje m x bateria 50V Compensaci n de temperatura 4 2 mV K por celula Voltage carga Autoconsumo idle 10 mA oma de tierra Positive aterrisado emperatura ambiente 40 a 50 C Altitud max 4 000 m sobre el nivel del mar ipo de bateria Plomo GEL AGM inundado Dimensiones LxAxA 140 x 90 x A0 mm Peso 420g Longitud max cableado 16 mm ipo de protecci n IP20 54 V ase gr fica de SOA Safe Operating Area Corriente PV nominal CMLsolid 30 SOA 160 140 120 100 0 20 40 60 80 100 120 140 160 Corriente consumo nominal 55 Exenci n de responsabilidad El fabricante no se hace responsable de los da os causados especialmente en la bateria por otro uso que no sea el previsto o mencionado en este manual o si se descuidan las reco
18. Conector USB para suministro de energia de 5V para peque os dispositivos como carga de tel fonos m viles ordenadores port tiles reproductores de musica peque os hasta 800 mA de consumo de corriente Advertencia No conecte el aparato en proceso de carga en otro lugar Contacto negativo de USB esta conectado al consumo negativo Terminal de control remoto del inversor Disponible un conector modular 6p4c tipo RI para controlar cualquier inversor de la serie SI de inversores Phocos SI 350 SI 700 o SI 1500 en la funci n de detecci n de bajo voltaje del controlador de carga El inversor no se apaga cuando se produce una sobrecorriente en el consumo El conector CMLsolid 30 para el control remoto de inversores esta dise ado para funcionar directamente con el protocolo Modbus y con cables de conexi n telef nica 1 1 Conecte el inversor directamente a la bateria La funci n de descenso del estado de la carga SOC nonose puede utilizar entonces porque el conector CMLsolid 30 no puede medir la corriente que llega del inversor 49 50 Descripci n de errores Error Visualizaci n de errores Causa Soluci n El consumo se volver a La bateria est baja conectar tan pronto LED rojo encendido como la bateria este cargada Desconectar todos los Y mer consumos Eliminar Sobrecorriente Cortocircui SE _ ks cortocircuito El to de consumos proteger controlador activar and I de sobretemperat
19. V the controller assumes a 24 V system If the battery voltage is not within the normal operation range at start up a status display according to the section ERROR DESCRIPTION occurs Battery Type The controller is preset to operate with lead acid batteries with solid electrolyte GEL type or AGM type If you intend to use a lead acid battery with liquid electrolyte you can adjust the charging 24 characteristics see Settings The equalization charge modus is added then In case of any doubts consult your dealer Recommendations for Use The controller warms up during normal operation The controller does not need any maintenance or service Remove dust with a dry tissue It is important that the battery gets fully charged frequently at least monthly Otherwise the battery will be permanently damaged A battery can only be fully charged if not too much energy is drawn during charging Keep that in mind especially if you install additional loads Display Functions in normal operation The controller is equipped with 5 LEDs and an acoustic warning signal phocos State of charge LED Ch LED arge BR Load status LED In normal operation the controller shows the state of charge of the battery and the solar panel activity Any change of the state of charge SOC to a lower status is additionally signaled acoustically Charge display aly ale 7 1 d re Solar array supplies electricity Solar a
20. conectada ao controlador este inicia uma rotina de autoteste Na sequ ncia passa ent o para a opera o normal Tens o do sistema O controlador automaticamente se autoajusta tens o do sistema 12 V ou 24 V Sistemas com tens o gt 18 V S o reconhecidos como sistemas 24 V Caso a tens o da bateria n o se encontre dentro dos limites esperados o controlador exibir a indica o de falha Tipos de baterias O controlador de carga foi projetado para o funcionamento com baterias tipo chumbo cida com eletr lito imobilizado GEL ou AGM Caso seja desejado utilizar baterias de chumbo cida com eletr lito l quido as caracter sticas de carga poder o ser ajustadas vide Configurac es Neste caso o processo de carga ser ampliado incluindo a equaliza o Em caso de d vidas consulte seu revendedor Recomenda es para uso O controlador de cargas se aquece durante opera o normal O controlador n o requer manuten o ou servi o Remova qualquer poeira com um pano seco importante que a bateria esteja sempre carregada com frequ ncia ao menos uma vez por m s Caso contr rio ser permanentemente danificada A bateria somente atingir plena carga quando n o houver demanda excessiva de energia durante o processo de carga Lembre se deste fato em especial quando instalar consumidores adicionais 81 Sinaliza o por LED em opera o normal O controlador est equipado com 5 LEDs e um s
21. entspricht dabei der bis zum Tiefentlade Abschaltpunkt entnehmbaren Energie in Relation zur vollgeladenen Batterie Akustische Signale Bei einem Wechsel des Ladezustandes SOC nach unten wird dies durch eine entsprechende Anzahl von Signalt nen signalisiert Die Lastabschaltung erfolgt ca 1 Minute nach einer Serie von 25 Signalt nen Lastzustandsanzeige Der Laderegler schaltet bei Tiefentladung und bei berlastung Lastkurzschluss den Lastausgang ab Dies wird angezeigt durch El J e m la d Ly a X B X X amp Normalbetrieb Tiefentladeschutz berlast oder Lastkurzschluss Rote LED aus Rote LED an Rote LED blinkt Tiefentladeschutz LVD Der Regler verf gt ber 2 verschiedene Modi zum Schutz der Batterie gegen Tiefentladung 1 Ladezustandsgesteuert Abschaltung bei 11 4 V 22 8 V bei Last Nennstrom bis 11 9 V 23 8 V bei keinem Laststrom Modus mit guten Batterieschutz Eigenschaften 2 Spannungsgesteuert Abschaltung 11 0 V 22 0 V fix geeignet falls Verbraucher direkt an die Batterie angeschlossen sind und der Laderegler nicht den gesamten Laststrom erfassen kann Werkseitig ist der Modus 1 voreingestellt Die Einstellung des Modus ist unten beschrieben Einstellungen Der Laderegler kann auf besondere Betriebsanforderungen eingestellt werden Mit Hilfe von drei DIP Schaltern an der linken Seite des Reglers k nnen folgende Einstellun
22. erw rmen kann muss er auf einem nicht brennbaren Untergrund montiert werden 3 Bitte schlie en Sie den Laderegler in jedem Fall in der nachfolgend angegebenen Reihenfolge an um Anschlussfehler zu vermeiden Beachten Sie folgende Anschlussreihenfolge bei der Inbetriebnahme des Systems 1 Verbinden Sie die Batterie mit dem Laderegler Plus und Minus 2 Verbinden Sie die PV Module mit dem Laderegler Plus und Minus 3 Verbinden Sie die Last mit dem Laderegler Plus und Minus Befolgen Sie bitte die Reihenfolge in umgekehrter Folge beim Abbau des Systems Um spannungsfrei zu arbeiten schlie en Sie bitte die Kabel zuerst an den Regler dann an die Batterie und zuletzt an die PV Module an F r die Last gilt bitte zuerst die Kabel an die Last anschlie en dann am Regler Empfohlener mindest Kabelquerschnitt 10 mm Vergewissern Sie sich dass die Kabell nge zwischen Batterie und Laderegler so kurz wie nur m glich ist Bedenken Sie dass die positiven Anschl sse des CMLsolid zusammengef hrt sind und deshalb das gleiche elektrische Potential haben Sollte eine Erdung des Systems n tig sein darf dies nur an den Plus Leitungen geschehen F r die Erdung des Laderegler Geh uses ist auch eine separate Erdungsklemme vorhanden Erdungsklemme CML soio phoco Anschluss zum fernsteuern eines 17 Wechselrichters USB Anschluss HINWEIS
23. for special operation With three DIP switches on the left of controller the following settings can be configured BUZ LVD GEL ON OFF Three DIP switches are available on the left side of controller 28 DIP Switch BUZ LVD GEL d A A Function of low voltage Function Acoustic alarm signal disconnect Battery type Setting on Alarm on State of charge controlled GEL VRLA battery Setting off Alarm off Voltage controlled Flooded battery Factory setting Alarm on State of charge controlled GEL VRLA battery Safety Features PV terminals Battery terminals Load terminals Reverse polarity Protected Warning Red LED on 1 Protected 1 Short circuit Protected 2 Protected 3 Protected 2 Over current Switches off with a delay 4 Reverse current Protected Over voltage Max 50 V Max 50 V Switches off above 15 5 31 0V 29 PV terminals Battery terminals Load terminals Under voltage Switches off Reduces the charging current if over temperature occurs and switches off Over temp the load ifthe temperature reaches high level 1 Controller can protect itself but any connected loads might be damaged 2 Short circuit Maximum interruption current capacity lt 400 A 3 Battery must be protected by a fuse or it might be permanently damaged in case of short circuit 4 gt 200 nominal curr
24. 1 9 22 8 23 8 V by SOC 11 0 22 0 V by voltage 34 Reconnect level 12 8 25 6V Undervoltage protection 10 5 21 0V Max panel voltage 50V Max battery voltage 50V Temperature compensation 4 2 mV K per cell Charge voltage Self consumption idle 10 mA Grounding Positive grounding Ambient temperature 40 to 50 C Max altitude 4 000 m above sea level Battery type Lead acid GEL AGM flooded Dimensions WXHXD 140 x 90 x 40 mm Weight 420g Max wire size 16 mm Type of protection IP20 35 Please see graph of SOA Safe Operating Area Nominal PV current 160 140 120 100 CMLsolid 30 SOA 20 40 60 80 100 120 140 160 Nominal load current 36 Liability Exclusion The manufacturer shall not be liable for damages especially on the battery caused by use other than as intended or as mentioned in this manual or if the recommendations of the battery manufacturer are neglected The manufacturer shall not be liable if there has been service or repair carried out by any unauthorized person unusual use wrong installation or bad system design Subject to change without notice Version 20130624 Made in one of the following countries 1509001 Germany China Bolivia India Phocos AG Germany C Ro HS www phocos com 37 Estimado Usuario Muchas gracias por adquirir un producto d
25. 25 pitidos 45 Visualizaci n del estado del consumo En caso de descarga profunda o sobrecarga cortocircuito del consumo se desconecta la salida del consumo Esto se indica por a ss ud 2 Se L 5 x CR EK Funcionamiento normal Desconexi n por Bajo Voltaje Sobrecarga o Cortocircuito del consumo LED rojo apagado LED rojo encendido LED rojo parpadea Funci n de Desconexi n por Bajo Voltaje El controlador tiene 2 modos diferentes para proteger la bateria de una descarga profunda 1 Estado de la carga controlado Desconecta de 11 4 V 22 8 V a corriente de carga nominal hasta 11 9 V 23 8 V a falta de corriente Modo de funcionamiento normal para una buena protecci n de la bateria 2 Voltaje controlado Desconecta en el par metro fijo de 11 5 V 23 0 V Apropiado si otros consumos retiran corriente directamente de la bateria Salido de f brica el controlador est programado en el Modo 1 Mas adelante se describe c mo cambiar la configuraci n del modo 46 Configuraci n El controlador puede configurarse para funcionamientos especiales Con los tres interruptores DIP situados en el lateral izquierdo del controlador podra configurar los siguientes ajustes BUZ LVD GEL ENCENDIDO APAGADO Tres interruptores DIP situados en el lateral izquierdo del controlador Interruptor DIP BUZ LVD GEL e Senal de alarma Funci n de desconexi n n E Funci n ass Tipo de bateria acusti
26. 94 Exclus o de responsabilidade O fabricante nao se responsabiliza por danos especialmente na bateria resultantes do uso indevido ou adverso ao descrito neste manual ou da n o observ ncia das recomenda es feitas pelo fabricante da bateria O fabricante n o se responsabiliza pelos servi os ou reparos efetuados por pessoas n o autorizadas uso indevido instala o incorreta ou mal desempenho do sistema Sujeito a altera es sem aviso pr vio Vers o 20130624 Fabricado em um dos pa ses seguintes Alemanha China Bol via ndia 1509001 Phocos AG Alemanha www phocos com C RoHS 95 CMLsolid 30 e a e USB MP3 e 16 a AN
27. Bei Unklarheiten ber die erforderlichen Einstellungen wenden Sie sich bitte an Ihren H ndler Hinweise zum Betrieb Eine Erw rmung des Ladereglers im Betrieb ist normal Im Betrieb ben tigt der Laderegler keine besondere Wartung oder Pflege Entfernen Sie gelegentlich Staub mit einem trockenen Tuch Es ist sehr wichtig dass der Bleiakkumulator regelm ig zumindest monatlich immer wieder vollst ndig geladen wird Andernfalls wird die Bleibatterie dauerhaft gesch digt Die Vollladung kann vom Laderegler nur dann durchgef hrt werden wenn nicht gleichzeitig zu viel Energie entnommen wird Achten Sie insbesondere darauf wenn Sie zus tzliche Verbraucher an die Solaranlage anschlie en Anzeigefunktionen im Normalbetrieb Der Laderegler verf gt ber 5 LEDs und ein akustisches Warnsignal CML sold y phoco Ladezustandsanzeige H Ladeanzeige H H Lastzustandsanzeige SS Im Normalbetrieb zeigt der Laderegler den Ladezustand der Batterie und die Ladung durch das Solarmodul an Jede nderung des Ladezustandes SOC nach unten wird akustisch durch den Laderegler signalisiert Ladungsanzeige MS Solaranlage liefert Strom Gr ne LED leuchtet Ladezustandsanzeige gt 75 25 75 3 LEDs AN 2 LEDs AN Solaranlag Gr ne lt 25 1 LED AN 1 LED Blinkt lo 2 e liefert keinen Strom LED leuchtet nicht lt 10 Die Prozent Angabe
28. TTERIE ANSCHLIESSEN batterien GEL AGM fl ssigs ure Batterien Systemnennspannung der Batterie 12 oder 24 V Batteriesicherung Bitte verwenden Sie eine flinke Sicherung mit einem minimalen Ausschaltverm gen von 1000 A an der Batterieseite Wir empfehlen die flinke Sicherung z B Kfz Sicherung so nah wie m glich am Batteriepol anzubringen Der maximale Bemessungsstrom sollte dem 1 5 fachen des Nominalstroms des Ladereglers entsprechen Bitte versuchen Sie nicht die Produkte von Phocos zu zerlegen oder zu reparieren Phocos Laderegler enthalten keine Teile die vom Anwender selbst repariert werden nnen Bitte beachten Sie alle aufgef hrten Anweisungen in Bezug auf externe Sicherungen Strom reisunterbrecher Wartung und Installationshinweise Bei der Installation oder beim Arbeiten an der PV Anlage bitte immer zuerst die PV Solarmodule vom Laderegler trennen um eventuelle Sch den am Laderegler zu vermeiden Bitte berpr fen Sie dass alle Kabel Leitungsverbindungen fest mit den Anschl ssen und Verbindungsstecker angeschlossen sind um nicht durch lose oder schlechte Verbindungen eine Hitzeentwicklung zu verursachen Bitte schlie en Sie zuerst eine Sicherung oder einen Unterbrecher in der N he der Batterie an bevor Sie den Laderegler einstellen oder anschlie en Bitte betreiben und montieren Sie den Laderegler in trockener Umgebung Hochspannungsrisiken Der Betrieb dieses Ger tes kann Hochspannung erzeuge
29. a Fun es de seguran a Terminais painel solar Terminais bateria Terminais consuidor Polaridade inversa Prote o ativa Sinaliza o LED vermelho ligado 1 Prote o ativa 1 Curto circuito Prote o ativa 2 Prote o ativa 3 Prote o ativa 2 Sobrecarga Desliga com retardo 4 Corrente inversa Protegido 86 Terminais painel solar Terminais bateria Terminais consuidor Desliga com tens o Sobretens o Max 50V Max 50 V acima de 15 5 31 0V Subtens o Desliga Reduza corrente de carga em caso de sobreaquecimento e desconecta a Sobreaquecimento ET carga na temperatura limite 1 O controlador de cargas se autoprotege consumidores poder o todavia ser danificados 2 Curto circuito Capacidade m xima de interrup a lt 400 A 3 A bateria dever estar protegida por fus vel ou diseuntor ou ser permanentemente danificado por curto circuito 4 Corrente nominal gt 200 desconecta com 3 s de retardo Cuidado Uma combina o de diferentes falhas poder danificar o controlador Elimine sempre qualquer condi o de falha antes de prosseguir com as conex es do controlador Terminais auxiliares Terminais Conectores Auxiliares Conector USB O conector USB fornece 5 V e destinado alimenta o de pequenos aparelhos como por exemplo telefones celulares pequenos computadores tocadores com um
30. a corrente consumo de at 800 mA Cuidado N o conecte o conector USB a qualquer outro ponto el trico do sistema O contato negativo do conector USB est diretamente conectado ao polo negativo da bateria 87 Terminal remoto para controle de inversores Phocos Um conector modular tipo 6p4c est disponivel para controlar qualquer inversor da serie Phocos SI 350 SI 700 ou SI 1500 na fun o desconex o por baixa tens o LVD do controlador de carga O inversor nao se ligara na condi o de sobrecarga O terminal para controle remoto de inversores disponivel no controlador de carga CMLsolid 30 foi projetado para a utiliza o direta com inversores de energia da s rie SI da Phocos Conex o atrav s de conectores tipo MODBUS utilizando conector padr o RJ conex o 1 1 Nesta modalidade o inversor dever ser conectado diretamente com bateria A fun o SOC Estado de carga n o devera ser utilizada neste caso pois o CMLsolid30 n o mede o n vel de corrente demandada pelo inversor Sinaliza es de falha Sinaliza o LED Causa Solu o E S Carga ser Bateria com baixa carga reconectada tao logoa e bateria seja d x LED vermelho ligado J S CH recarregada N o h energia Consumidores desconectados Sobrecorrente Curto Ema E GE Eliminar curto circuito circuito na O controlador se reconectara automaticamente ap s 1 minuto carga Prote o contra Sobreaquecimento LED verm
31. a tens o Sobrecarga ou curto circuito terminal carga LED vermelho desligado LED vermelho ligado LED vermelho piscando Fung o Desconex o por Baixa Tens o LVD O controlador de carga possui 2 diferentes modalidades para proteger a bateria de uma descarga total 1 Controle por estado de carga desconecta em 11 4 V 22 8 V na corrente nominal at 84 11 9 V 23 8 V sem fluxo de corrente Esta a modalidade de opera o oferece uma boa protec o para a bateria 2 Controle por tens o Desconecta ao atingir os niveis de tens o de bateria de 11 5V 23 0V Apropriado para circuitos com mais de um consumidor ligado diretamente a bateria O controlador est pr ajustado de f brica no modo 1 Para alterar esta configura o vide descri o abaixo Configura es O controlador de cargas pode tamb m ser configurado para condi es de opera o espec ficas Atrav s de tr s interruptores DIP no lado esquerdo do controlador poder o ser feitas as as BUZ LVD GEL Ligar ON Desligar OFF Tr s interruptores tipo DIP encontram se no lado esquerdo do controlador de carga 85 Interruptores pip BUZ LVD GEL Fun o Fun o sinaliza o Desconex o por Baixa Tipo de bateria acustica Tens o Ajuste on Ligado Estado de carga GEL bateria VRLA Ajuste off Desligado Tens o bateria Eletr lito liquido Progresso de Ligado Estado de carga GEL bateria VRLA carg
32. ca por bajo voltaje Ajuste activado Alarma activada Estado de carga controlado GEL bateria VRLA Ajuste Alarma desactivada Voltaje controlado Bateria inundada desactivado Ajuste de factoria Alarma activada Estado de carga controlado GEL bateria VRLA 47 Caracteristicas de Seguridad Bornes FV Bornes de la bateria Bornes de consumo A e E Precauci n LED rojo Polaridad inversa Protegido encendido 1 Protegido 1 Cortocircuito Protegido 2 Protegido 3 Protegido 2 cobreconi nt o Se apaga con retardo 4 Corriente inversa Protegido Sobrevoltaje M x 50V M x 50 V Se apaga por encima de 15 5 31 0 V Subvoltaje Se apaga Sobrecalentamiento Reduce la corriente de carga si se produce un sobrecalentamiento y desconecta el consumo si la temperatura es demasiado alta 1 El controlador se protege a s mismo pero se pueden da ar otros consumos conectados 2 Cortocircuito Protecci n electr nica limitada contra sobrecorriente lt 400 A 3 La bater a se ha de proteger mediante un fusible o se puede da ar permanentemente en caso de cortocircuito 4 gt 200 corriente nominal desconectar con un retardo de 3s 48 ADVERTENCIA La combinaci n de diferentes circunstancias de error puede da ar el controlador iCorrija siempre un error antes de proseguir con la conexi n del controlador Conectores Terminales auxiliares Conector USB
33. ci n de las funciones m El controlador de carga protege a la bateria contra posible sobrecarga del m dulo solar y evita que sea fuertemente descargada durante los consumos Las caracteristicas de la carga comprenden diversos estadios que incluyen la adaptaci n autom tica a la temperatura ambiente El controlador de carga se ajusta autom ticamente al sistema de voltaje de 12V o 24V El controlador de carga tiene varias funciones de seguridad y visualizaci n Montaje y aterrizage El controlador esta pensado nicamente para su uso en interiores Prot jalo de la luz directa del sol y col quelo en un lugar seco No debe instalarlo nunca en habitaciones h medas como ba os El controlador mide la temperatura ambiente para determinar el voltaje de la carga El controlador y la bater a deben instalarse en la misma habitaci n El controlador se calienta durante su funcionamiento y por lo tanto ha de instalarse nicamente sobre una superficie no inflamable Para evitar errores de instalaci n conecte el controlador siguiendo los pasos descritos a continuaci n m Tenga en cuenta la siguiente secuencia de conexi n cuando ponga en marcha el sistema 1 Conecte la bater a al controlador de carga polo positivo y polo negativo 2 Conecte los m dulos fotovoltaicos al controlador de carga polo positivo y polo negativo 3 Conecte el consumo al controlador de carga polo positivo y polo negativo Siga el procedimiento inverso a la hora d
34. da remoto para ativar desativar um inversor m Controlador de carga para dispositivos eletr nicos port teis utilizando conectores USB padr o s i A 2 m Terminais de conex o para condutores com at 16 mm m Prote o eletr nica completa INSTRUG ES DE SEGURAN A IMPORTANTES IN ACONSELHAMOS GUARDAR ESTE MANUAL Este manual cont m recomenda es importantes que dever o ser seguidas durante a instala o opera o e manuten o do controlador de carga CMLsolid 30 PERIGO DE INCENDIO UTILIZAR O CONTROLADOR EM DIST NCIAS DE NO MINIMO DISTANTE 0 5m DAS BATERIAS Pr prio para baterias tipo chumbo acida GEL AGM Liquida 76 Tens o nominal da bateria 12V ou 24 V Fusivel no circuito da bateria Utilize o fusivel de a o r pida com capacidade nominal de corrente compativel com o circuito e uma capacidade de interrup o curto circuito minima de 1000 A no lado da bateria Recomendamos a utiliza o de fusivel de a o r pida por exemplo fusiveis automotivos instalados o mais pr ximo possivel do polo terminal da bateria A corrente maxima de carga nao dever exceder a 1 5 vezes a corrente nominal do controlador de carga Por gentileza n o desmonte ou tente consertar os produtos da Phocos Os controladores de carga da Phocos n o cont m pe as que possam ser reparadas pelo usu rio Leia por favor todas as instru es com respeito s indica es quanto ao uso de fus veis externos disjuntores Observa e
35. de corriente deberia ser 1 5 veces la corriente nominal del controlador de carga No intente reparar ni desarmar los productos Phocos Los controladores de carga Phocos no contienen partes reutilizables para el usuario Tenga en cuenta todas las instrucciones en lo que respecta a fusibles externos interruptores tal como se indica Informaci n sobre el mantenimiento y la instalaci n Durante la instalaci n o el uso del sistema FV desconecte en primer lugar los m dulos FV solares del controlador de carga para evitar danos en el controlador de carga Verifique que todas las conexiones de los cables est n bien ancladas a los conectores puertos de conexi n para evitar la existencia de cables sueltos o mal colocados que pudieran provocar un calentamiento excesivo nstale un fusible o interruptor cerca de la bateria antes de proceder con la instalaci n o ajuste del controlador nstale y utilice el controlador en un ambiente seco Riesgos de alto voltaje La utilizaci n de este equipo puede producir un alto voltaje que podria provocar lesiones graves o la muerte en caso de una mala instalaci n o un uso inadecuado del aparato Los m dulos FV pueden generar altos voltajes de CC Aseg rese de que los cables est n conectados a los bornes correctos Una descarga el ctrica puede ser mortal En general cualquier descarga el ctrica puede ser peligrosa para la salud Marca CE Producto provisto del marcado CE 39 Descrip
36. e il lance un autocontr le de routine Puis l affichage passe en fonctionnement normal Tension du syst me Le r gulateur de charge s ajuste automatiquement la tension du syst me en 12 V ou 24 V D s que la tension d passe 18 0 V au d marrage le r gulateur passe automatiquement en 24 V Si la tension de la batterie ne se situe pas dans la plage normale de fonctionnement au d marrage cela est signal sur l cran d affichage voir chapitre DESCRIPTION DES ERREURS Type de batterie Le r gulateur est pr r gl pour fonctionner avec des batteries au plomb comportant des lectrolytes solides de type GEL ou AGM Si vous avez l intention d utiliser une batterie au plomb avec des electrolytes liquides vous pouvez modifier les caract ristiques de charge voir PARAMETRES La charge d egalisation est alors activ e En cas de doute veuillez contacter votre distributeur Recommandations d utilisation Le r gulateur de charge chauffe lors qu il fonctionne normalement Le r gulateur ne requiert aucun entretien ni aucune maintenance Enlevez la poussi re avec un chiffon sec Il est important que la batterie soit fr quemment charg e jusqu pleine capacit au moins une fois par mois Le cas ch ant elle sera endommag e de fa on irr m diable Une batterie 62 peut tre enti rement charg e condition qu il n y ait pas trop d nergie consomm e au cours de son chargement Ceci est garder en m moire en part
37. e Phocos Antes de utilizar este producto lea las instrucciones detenidamente y al completo Su nuevo controlador CMLsolid 30 es un aparato moderno que ha sido dise ado siguiendo los ltimos criterios t cnicos posibles Incorpora toda una serie de caracteristicas sobresalientes como Visualizaci n clara y legible del estado de la carga Se al acustica cuando el estado de la carga cambia Desconexi n por bajo voltaje controlado por el estado de la carga o por el voltaje de la bateria Terminal remoto de salida para el encendido apagado del inversor Cargador m vil para equipos externos mediante conector USB est ndar Terminales m x 16 mm Protecci n electr nica completa INSTRUCCIONES DE SEGURIDAD IMPORTANTES AN GUARDE ESTAS INSTRUCCIONES Este manual contiene instrucciones importantes para el controlador CMLsolid 30 que se han de seguir durante la instalaci n operaci n y el mantenimiento del controlador de carga PELIGRO DE INCENDIO NO UTILICE EL CONTROLADOR A MAS DE 0 5m alejado DE LAS BATERIAS Tipo de bateria Plomo GEL AGM liquida Potencia de voltaje nominal de la bater a 12 624 V Fusible de la bateria utilice un fusible de acci n r pida con una capacidad nominal minima de 38 corriente de interrupci n de 1000 A en el lado de la bateria Recomendamos utilizar un fusible de usi n r pida p ej tipo de fusibles para autom viles situado lo m s pr ximo posible al borne de la bateria La capacidad m xima
38. e desinstalar el sistema m Para evitar voltaje en el cableado conecte en primer lugar el cable al controlador y despu s a la bater a de los m dulos fotovoltaicos Sin embargo para el consumo conecte primero el cable al consumo y a continuaci n al controlador m Tama o m nimo recomendado de los cables 10 mm 40 Terminal de control remoto del inversor CM Lsotc Conector USB Posici n detoma de tierra Fusible el JO 41 m Aseg rese de que la longitud de los cables entre la bater a y el controlador sea lo m s corta posible m Tenga en cuenta que los bornes positivos del controlador CMLsolid 30 est n conectados internamente y por lo tanto tienen el mismo potencial el ctrico Si se requiere toma de tierra efect ela siempre en los cables positivos El cabinete del controlador de carga podu ser aterrisado a trav s de un terminal dedicado disponible para esta funcci n OBSERVACI N Si se utiliza el aparato en un veh culo que tenga el negativo de la bater a en el chasis los consumos conectados al regulador no deben tener una conexi n el ctrica a la carrocer a de otro modo se producir a un cortocircuito en las funciones de Desconexi n por Bajo Voltaje y de fusible electr nico OBSERVACI N Siga las recomendaciones del fabricante de su bater a Recomendamos encarecidamente conectar un fusible direc
39. elho pisca 89 N o h energia Tens o de bateria elevada gt 15 5 31 0V Verificar se h outras fontes de energia sobrecarregando a bateria Neste caso desconectar imediatamente caso contrario controlador est danificado Condutores ou fus veis da bateria est o danificados bateria com resist ncia interna elevada Verifique os condutores e fus veis da bateria e tamb m a bateria propriamente dita Vida reduzida da bateria Baixa Capacidade da bateria LED vermelho ligado Troque a bateria 90 Caso n o tenha sido Painel solar defeituoso a Remova a conex o carregada ou polaridade A See y A invertida inverta a durante o AE invertida LED verde olavidade processo de de desligado P carga a Polaridade Bateria est conectada incorreta da com polaridade Corre o da bateria ie s inversa polaridade LED vermelho ligado Especificag es t cnicas Nota Niveis de tens o indicados antes e ap s da respectivamente barra s o aplic veis para sistemas em 12V e 24V Especificag es T cnicas CMLsolid 30 Tens o de sistema 12 24 V reconhecimento autom tico Maxima corrente de carga 30 A Maxima corrente de consumo 30 A Tens o de flutuag o 13 8 27 6 V 25 C Nivel de tens o carga principal 14 4 28 8 V 25 C 0 5 h diariamente Nivel de ten
40. emperature protect on load automatically x Red LED flashing after max 1 minute 32 Loads are not Battery voltage too high gt 15 5 31 0V Check if other sources overcharge the battery If not controller is damaged supplied Battery cables or battery fuse damaged Check battery wires battery has high fuses and battery resistance Battery is Battery shows low empty after a capacity Red LED on Change battery short time Battery is not being charged during the day Solar array faulty or reverse polarity Green LED off Remove faulty connection reverse polarity Battery reverse polarity Battery is connected with reverse polarity Red LED on Remove reverse polarity 33 Technical Data Note The voltage levels before after the slash are va id for 12 V and 24 V systems respectively Technical Data CMLsolid 30 System voltage 12 24 V auto recognition Max charge current 30 A Max load current 30 A Float charge 13 8 27 6 V 25 C Main charge 14 4 28 8 V 25 C 0 5 h daily Boost charge 14 4 28 8 V 25 C 2h Activation battery voltage lt 12 3 24 6 V Equalization 14 8 29 6 V 25 C 2h Activation battery voltage lt 12 1 24 2 V at least one time every 30 days Overvoltage protection 15 5 31 0V Deep discharge protection Cut off voltage 11 4 1
41. ent disconnect with 3s delay WARNING The combination of different error conditions may cause damage to the controller Always remove the fault condition before you continue with connecting the controller Auxiliary terminals USB connector USB connector for delivering 5V to small appliances like for charging Cell phones compact portable computers small music players with up to 800 mA of current consumption Warning Do not connect the charging device anywhere else USB Negative contact is connected to Load negative Remote terminal for inverter A modular 6p4c RJ tpye connector is available to control any inverter of the Phocos inverter SI series SI 350 SI 700 or SI 1500 by the LVD function of the charge controller The inverter will not be switched off at load over current 30 31 The CMLsolid 30 connector for remote control of inverters is designed to directly make use of Modbus or phone 1 1 connected type cables Connect the inverter directly to the battery The SOC function can not be used then because the CMLsolid 30 can t measure the current drawn by the inverter under these setting Error Description Error Display Reason Remedy A Load will reconnect as Battery is low soon as battery is rn Red LED on Geen pa Se recharged T Loads are not supplied S Switch off all loads _ B Overcurrent Short Remove short circuit circuit of loads Over Controller will switch de gt t
42. er protects the battery from being overcharged by the solar array and from being deep discharged by the loads The charging characteristics include several stages which include automatic adaptation to the ambient temperature The charge controller adjusts itself automatically to 12V or 24V system voltage The charge controller has a number of safety and display functions Connecting and Grounding The controller is intended for indoor use only Protect it from direct sunlight and place it in a dry environment Never install it in humid rooms like bathrooms The controller measures the ambient temperature to determine the charging voltage Controller and battery must be installed in the same room The controller warms up during operation and should therefore be installed on a non flammable surface only Connect the controller by following the steps described below to avoid installation faults Observe the following connection sequence when installing the system 1 Connect the battery to the charge controller plus and minus 2 Connect the photovoltaic modules to the charge controller plus and minus 3 Connect the load to the charge controller plus and minus Follow the reverse procedure when uninstalling To avoid any voltage on the wires first connect the wire to the controller then to the battery photovoltaic modules But for load first connect the wire to the load then to the controller Recommended minimum wire size 10 m
43. erden 4 gt 200 Nennstrom Abschaltung nach 3 Sekunden Verz gerung WARNUNG Die Kombination verschiedener Fehler kann dem Laderegler Schaden zuf gen Bitte beheben Sie unbedingt zuerst den Fehler bevor Sie mit dem Anschlie en des Ger ts fortfahren Weitere Ausg nge USB Anschluss Der USB Anschluss liefert 5 V f r Kleinger te wie Mobiltelefone Tablet PCs und Musikspieler mit einer Stromaufnahme von bis zu 800 mA Warnung Verbinden Sie das zu ladende Ger t mit nichts anderem Der Negative USB Kontakt wird mit dem negativen Lastanschluss verbunden 12 Fernsteuerungsanschluss f r einen Wechselrichter Zur Steuerung der Phocos Wechselrichter Serie SI 350 SI 700 oder SI 1500 durch die Tiefentladeschutz Funktion LVD des Ladereglers ist eine 6p4c Modularbuchse vorhanden Der Wechselrichter wird bei Last berstrom nicht abgeschaltet phoco CML solia 13 Der CMLsolid 30 Anschluss zur Fernsteuerung der Wechselrichter ist f r direkte Verwendung von Modbus oder 1 1 Telefonkabeln ausgelegt Verbinden Sie bitte den Wechselrichter direkt mit der Batterie Die Ladezustandssteuerung SOC kann nicht verwendet werden weil der CMLsolid 30 die Stromaufnahme des Wechselrichters nicht messen kann Fehlerbeschreibung Fehler LED Anzeige Ursache Fehlerbehebung Je Last schaltet Batterie ist tiefentladen automatisch zu wenn m Rote LED an die Batterie pa gt nachgeladen wurde Verbraucher haben keine
44. ff rentes sources d erreurs peut endommager le r gulateur Pour cette raison veillez corriger toute erreur avant de poursuivre les tapes de branchement du r gulateur Bornes auxiliaires Port USB Le port USB permet de fournir 5 V pour des petites applications comme le rechargement de t l phones portables d ordinateurs portables et de lecteurs de type mp3 consommant jusqu 800 68 mA de courant AVERTISSEMENT Ne branchez pas le dispositif de rechargement sur d autres bornes Le contact n gatif du port USB est connect a la borne n gative de la charge Bornes de contr le a distance de l onduleur Un connecteur modulaire de type 6p4c type RJ est disponible pour contr ler chaque onduleur de la s rie SI de Phocos savoir SI 350 SI 700 et Sl 1500 pour le mode de fonctionnement LVD du r gulateur de charge Londuleur n est pas mis hors fonction dans le cas d une surcharge Le connecteur de contr le a distance des onduleurs dont le r gulateur CMLsolid 30 est quip est con u pour tre utilis directement avec les cables reli s a un protocole modbus ou un t l phone connexion 1 1 Branchez l onduleur directement sur la batterie Dans ce cas la fonction SOC ne peut pas tre utilis e car le r gulateur CMLsolid 30 ne peut mesurer le courant consomm par l onduleur Description des erreurs Erreur Affichage Cause Solution La charge sera La batterie est faible rec
45. gen vorgenommen werden BUZ LVD GEL AN AUS Die drei DIP Schalter befinden sich an der linken Seite des Ladereglers 10 DIP Schalter BUZ LVD GEL A Funktion des a Funktion Akustischer Alarm Tiefentladeschutzes Batterietyp Einstellung An Alarm An Ladezustandsgesteuert GEL VRLA Batterie a ng Alarm Aus Spannungsgesteuert Fl ssigs ure Batterie Werks gt Alarm An Ladezustandsgesteuert GEL VRLA Batterie einstellung Schutzfunktionen An den PV An den Batterie An den Last Anschliissen Anschl ssen Anschl ssen Verpolung Gesch tzt Warnung Rote LED leuchtet 1 Gesch tzt 1 Kurzschluss Gesch tzt 2 Gesch tzt 3 Gesch tzt 2 berstrom Schaltet verz gert aus 4 R ckstrom Gesch tzt 11 An den PV An den Batterie An den Last Anschliissen Anschliissen Anschliissen Uberspannung Max 50V Max 50V a ber 15 3 31 0V Unterspannung Schaltet aus Reduziert den Ladestrom bei bertemperatur und schaltet die Last aus wenn die bertemperatur x y P Temperatur einen hohen Wert erreicht hat 1 Der Laderegler kann sich selbst sch tzen aber angeschlossene Verbraucher k nnen besch digt werden 2 Kurzschluss Maximales Abschaltverm gen lt 400 A 3 Die Batterie muss durch eine Sicherung gesch tzt werden oder sie kann im Falle eines urzschlusses dauerhaft besch digt w
46. humidit et des rayons du soleil directs En aucun cas il ne doit tre install dans un endroit humide tel qu une salle de bain Le r gulateur mesure la temp rature ambiante afin d adapter la tension de charge La batterie et le r gulateur doivent tre install s dans la m me pi ce Lors de son fonctionnement la temp rature du r gulateur augmente consid rablement il est donc important de l installer uniquement sur une surface non inflammable Raccordez le r gulateur en suivant les tapes d crites ci dessous afin d viter les erreurs d installation m Respectez les tapes de branchement suivantes lors de la mise en service du syst me 1 Branchez la batterie au r gulateur de charge en respectant les polarit s et 2 Raccordez les panneaux photovolta ques au r gulateur de charge en respectant les polarit s et 3 Raccordez les charges au r gulateur de charge en respectant les polarit s et 59 Pour debrancher le r gulateur de charge suivez ces m mes instructions en sens inverse m Pour viter tout risque de tension sur les cables raccordez d abord le fil au r gulateur avant de le relier a la batterie et aux panneaux photovoltaiques Cependant pour la charge il convient de tout d abord brancher le fil sur la charge avant de le raccorder au r gulateur m La dimension minimale recommand e pour les c bles est de 10 mm m Veillez en outre ce que le cable qui relie la batterie au r gulate
47. iculier si vous installez des charges suppl mentaires Fonctions d affichage en cours de fonctionnement normal Le r gulateur de charge est quip de 5 LED et d un dispositif d alerte sonore CML solid El phoco Affichage de l tat de E charge Affichage de a la charge E E Affichage du statut de la charge H e H A a7 En fonctionnement normal le r gulateur de charge indique le niveau de charge de la batterie et la charge provenant des panneaux photovolta ques Tout changement de l tat de charge SOC vers un statut inf rieur est en plus indiqu par un signal sonore 63 Affichage de la charge e Ts Les panneaux solaires fournissent de l lectricit Les panneaux solaires ne fournissent pas d lectricit LED verte allum e LED verte teinte Affichage de l tat de charge gt 75 25 75 lt 25 lt 10 3 LED jaunes allum es 2 LED jaunes allum es 1 LED jaune allum e 1 LED jaune clignote Les pourcentages correspondent l nergie disponible jusqu la d connexion basse tension li e un chargement complet de la batterie 64 Signaux sonores Tout changement de l tat de charge SOC vers un statut inf rieur est indiqu par un signal sonore Les charges sont d branch es automatiquement environ 1 minute apr s une s rie de 25 signaux sono
48. inalizador ac stico CML solid phoco Estado de carga SOC Gera o A Consumidor Carga Durante opera o normal o controlador mostra o estado de carga da bateria e da energia recebida dos pain is solares Qualquer altera o no estado de carga SOC para uma condi o critica ser tamb m sinalizada atrav s de sinal ac stico 82 Sinalizag o do processo de carga so Y 1 x l O painel solar fornece energia O painel solar n o fornece energia LED verde aceso LED verde apagado Exibi o do estado de carga mmm gt 75 25 75 lt 25 lt 10 3 LEDs amarelos ligados 2 LEDs amarelos ligados 1 LED amarelo ligado 1 LED amarelo piscando Percentagem correspondente energia dispon vel em rela o bateria completamente carregada at chegar ao estado Desconex o por Baixa Tens o LVD Sinais Ac sticos Uma altera o no Estado da Carga SOC para um estado de carga inferior cr tica sinalizada atrav s sinal ac stico 83 Os consumidores ser o desconectadas aproximadamente 1 minuto ap s uma sequ ncia de 25 tons Condi o de consumidor Ocorrendo descarga profunda ou sobrecarga curto circuito da carga a saida do controlador sera desligada Isto sinalizado da seguinte forma aus de D D L 4 Operag o normal Desconex o baix
49. ivierung Batteriespannung lt 12 3 24 6 V 14 8 29 6 V 25 C 2 Std Ausgleichsladung Aktivierung Batteriespannung lt 12 1 24 2 V mindestens einmal alle 30 Tage berspannungsschutz 15 5 31 0V Tiefentladeschutz 11 4 11 9 22 8 23 8 V durch SOC 16 Abschaltspannung 11 0 22 0 V durch Spannung Wiedereinschaltspannung 12 8 25 6 V Unterspannungsschutz 10 5 21 0V Max PV Spannung 50V Max Batteriespannung 50V Temperaturkompensation Ladespannung 4 2 mV K per cell Ruhestromaufnahme 10 mA Erdung Positiv Erdung Umgebungstemperatur 40 bis 50 C Max H he 4 000 m NN Batterietyp Blei GEL AGM Fl ssigs ure Abmessungen BxHxT 140 x 90 x 40 mm Gewicht 420g Max Kabelquerschnitt 16 mm Schutzklasse IP20 17 Siehe Graph der Ladezustandssteuerung Sicherer Betriebsbereich CMLsolid 30 Sicherer Betriebsbereich 160 140 120 100 80 PV Nennstrom 20 0 20 40 60 80 100 120 140 160 Nennlaststrom 18 Haftungsausschluss Der Hersteller haftet nicht f r Sch den insbesondere an der Batterie die durch eine nicht wie vorgesehene oder wie im Handbuch beschriebene Verwendung entstehen oder wenn die Empfehlungen des Batterieherstellers missachtet werden Der Hersteller haftet nicht wenn Reparaturen oder Kundendienst von nicht autorisierten Personen durchgef hrt wurden bei u
50. m Make sure the wire length between battery and controller is as short as possible 22 Remote CM Lsotca Terminal for inverter 7 USB connector Grounding IF Post 23 m Be aware that all positive connections of CMLsolid 30 controller are common and therefore have the same electrical potential If any grounding is required always do this on the positive wire The charge controller casing can be grounded by means of an existent dedicated grounding post REMARK If the device is used in a vehicle which has the battery negative on the chassis loads connected to the regulator must not have an electric connection to the car body Otherwise the Low Voltage Disconnect function and the electronic fuse function of the controller are short circuited REMARK Mind the recommendations of your battery manufacturer We strongly recommend connecting a fuse directly to the battery to protect any short circuit at the battery wiring The fuse must correspond to the nominal current ofthe charge controller 45 A Starting up the controller Self Test As soon as the controller is supplied with power either from the battery it starts a self test routine Then the display changes to normal operation System Voltage The controller adjusts itself automatically to 12 V or 24 V system voltage As soon as the voltage at the time of start up exceeds 18 0
51. mend to use a fast acting melting fuse e g car type fuses as close as possible to the battery terminal The maximum current rating should be 1 5 times of the nominal current of the charge controller Please do not disassemble or attempt to repair Phocos products Phocos charge controllers do not contain user serviceable parts Please observe all instructions with regards to external fuses breakers as indicated Maintenance and installation notes When installing or working on the PV system please disconnect the PV solar modules from the harge controller first to prevent any damages to the charge controller a Please verify that all cable wire connections are tightly fastened to the connectors binding posts in rder to avoid any bad or loose connections that could result in excessive heating o Please install a fuse or breaker near the battery before installing or adjusting the controller Please install and operate the controller in a dry environment High voltage risks Operation of this device may produce high voltages which can cause severe injuries or death in case of improper installation or operation of the device PV modules can generate high DC voltages Make sure the cables are always connected to the correct terminal An electrical shock can be lethal n general any electric shock can be dangerous to your health CE labeling The product is CE compliant 21 Description of Functions The charge controll
52. mendaciones del fabricante de la bater a El fabricante no se hace responsable si se han llevado a cabo reparaciones a cargo de personal no autorizado o por un uso inusual una mala instalaci n o un mal dise o del sistema Sujeto a cambios sin aviso Version 20130624 1SO9001 Hecho en uno de los siguientes paises Alemania China Bolivia India C RoHS Phocos AG Alemania www phocos com 56 Cher Client Merci beaucoup d avoir achet un produit Phocos Veuillez lire avec attention toutes les instructions avant d utiliser le produit Votre nouveau r gulateur de charge solaire CMLsolid 30 a t d velopp d apr s les plus r centes techniques et conform ment aux normes actuellement en vigueur Il pr sente un certain nombre de caract ristiques sp cifiques telles que Affichage clair et lisible de l tat de charge Signal sonore en cas de changement de l tat de charge D connexion basse tension contr l e soit par l tat de charge soit par la tension Conecteurs de contr le distance pour la mise en marche arr t de l onduleur Chargeur portable pour les p riph riques externes quip s d un port USB standard Bornes de raccordement de 16 mm au maximum Protection lectronique totale CONSIGNES DE S CURIT IMPORTANTES AN CONSERVEZ CES INSTRUCTIONS Ce manuel contient des instructions importantes pour installation operation maintenance du r gulateur de charge solaire CMLsolid 30 Ces instructions doi
53. n was bei unsachgem er Installation oder Verwendung zu schweren Verletzungen bis hin zum Tod f hren kann Solarmodule generieren hohe Gleichstrom Spannungen 2 Stromnetz und Ladestromrisiken Stellen Sie bitte sicher dass die Kabel immer an den passenden Anschluss Klemmen angeschlossen sind Ein Stromschlag kann t dlich sein Generell kann jeder Stromschlag gesundheitsgef hrdend sein CE Kennzeichnung Dieses Produkt entspricht den Richtlinien f r die CE Kennzeichnung Funktionsbeschreibung m Der Laderegler sch tzt die Batterie vor Uberladung durch den Solargenerator und Tiefentladung durch die Verbraucher Die Ladung erfolgt durch eine mehrstufige Ladecharakteristik die zus tzlich temperaturkompensiert ist um eine optimale Batterieladung zu erzielen m Der Laderegler erkennt selbstst ndig die Batteriespannung und stellt sich automatisch auf 12 V oder 24 V Betrieb ein m Der Laderegler besitzt eine Reihe von Schutz und Anzeigefunktionen Montage und Erdung Der Laderegler ist nur f r die Anwendung im Innenbereich geeignet Bitte sch tzen Sie den Laderegler vor Witterungseinfl ssen wie direkter Sonneneinstrahlung oder N sse und montieren Sie ihn in trockener Umgebung Der Laderegler darf nicht in Feuchtr umen wie z B Bader ume montiert werden Der Laderegler misst zur Bestimmung der Ladespannung die Temperatur Laderegler und Batterie m ssen im selben Raum untergebracht werden Da sich der Regler im Betrieb
54. nsachgem sser Gebrauch falscher Installation oder falscher Systemauslegung nderungen vorbehalten Version 20130624 1SO9001 Hergestellt in einem der folgenden L ndern Deutschland China Bolivien Indien C Phocos AG Deutschland RoHS www phocos com 19 Dear Customer Congratulations on buying your Phocos product Please read the instructions carefully and thoroughly before using the product Your new CMLsolid 30 controller is a state of the art device which was developed in accordance with the latest available technical standards It comes with a number of outstanding features such as Clear readable display of the state of charge Acoustic signal when the state of charge changes Low voltage disconnect regulated by state of charge or voltage Remote output terminal to switch on off an Inverter Mobile charger for external devices using USB standard connector Max 16 mm connector binding posts Complete electronic protection IMPORTANT SAFETY INSTRUCTIONS AN SAVE THESE INSTRUCTIONS This manual contains important instructions for CMLsolid 30 controller that shall be followed during installation operation and maintenance of the charge controller RISKS OF FIRE USE CONTROLLER WITHIN 0 5 m OF BATTERIES Battery type Lead acid GEL AGM flooded Nominal voltage rating of the battery 12 or 24V 20 Battery fuse Use a fast acting fuse with a minimum interrupt rating of 1000 A on the battery side We recom
55. o puede estar completamente cargada si durante los consumos no se pierde mucha energia Tenga esto en cuenta especialmente si instala consumos adicionales Funciones de visualizaci n en funcionamiento normal El controlador dispone de 5 LEDs y de una se al ac stica de aviso En funcionamiento normal el controlador muestra el estado de la carga de la bateria y la carga de los paneles solares Cualquier descenso del estado de la carga SOC se se ala ademas ac sticamente 43 CML soiig Visualizaci n de la carga d Visualizaci n de la carga al Ale N El m dulo solar suministra electricidad LED verde encendido phocos Visualizaci n del estado de la carga Sg Visualizaci n del SS estado del consumo al 2 El m dulo solar no suministra electricidad LED verde apagado 44 Visualizaci n del estado de la carga gt 75 25 75 lt 25 lt 10 3 LEDs amarillos encendidos 2 LEDs amarillos encendidos 1 LED amarillo encendido 1 LED amarillo parpadea El porcentaje indica la relaci n entre la energia disponible de una bateria cargada completamente y el minimo indicado con Desconexi n por Bajo Voltaje Senales ac sticas El descenso del estado de la carga SOC se indica mediante una se al acustica Se desconectan los consumos aprox 1 minuto despu s de una serie de
56. onnect e aussit t Sr D LED rouge allum e que la batterie sera d 4 x recharg e Les charges ne sont pas E Surtension court Le r gulateur mettre la aliment es circuit des charge Be zu charges Protection automatiquement en 2 x contre la surchauffe route apr s 1 minute H LED rouge clignote maxi 70 Les charges ne sont pas alimentees La tension de la batterie est trop lev e gt 15 5 V 31 0 V Verifier si d autres sources surchargent la batterie Le cas contraire le regulateur est endommag Les c bles ou le fusible de la batterie sont endommag s la batterie pr sente une r sistance lev e V rifier les cables de la batterie les fusibles et la batterie La batterie se d charge apr s une breve p riode La capacit de la batterie est faible LED rouge allum e Changer la batterie La batterie ne se recharge pas au cours de la journ e Les panneaux solaires sont mal branch s ou la polarit est incorrecte LED vert teinte Enlever le mauvais raccordement inverser la polarit La polarit de la batterie est incorrecte La batterie est branch e avec des polarit s invers es LED rouge allum e Corriger les polarit s invers es 71 Fiche technique NOTE les niveaux de tension figurant avant apres la barre transversale slash d signent respectivement des syst mes 12 V et 24V
57. res Affichage du niveau de charge En cas de d charge profonde ou de surcharge court circuit de la charge la sortie de la charge est automatiquement d connect e Ceci est indiqu comme suit FE a Ze db D d E Ye SS x Fonctionnement normal D connexion basse tension Surcharge ou court circuit de la charge LED rouge teinte LED rouge allum e LED rouge clignote 65 Fonction de deconnexion basse tension Le r gulateur dispose de 2 modes diff rents pour viter que la batterie ne se d charge compl tement 1 Etat de charge r gul d connexion a 11 4 V 22 8 V avec courant de charge nominal jusqu 11 9 V 23 8 V sans courant de charge nominal Ce mode de fonctionnement normal prot ge bien la batterie 2 Tension r gul e d connexion a 11 5 V 23 0 V param tres pr r gl s Ce mode est appropri si des charges d riv es consomment directement du courant de la batterie Le r gulateur est pr r gl sur le mode 1 sa sortie d usine Le changement des param tres est d crit ci dessous Param tres Le r gulateur de charge peut tre configur pour un fonctionnement sp cifique Les trois commutateurs DIP situ s sur le c t gauche du r gulateur permettent de modifier les param tres a BUZ LVD GEL MARCHE ON ARR T OFF 66 Commutateur DIP BUZ LVD GEL Fonction Signal sonore Fonction d connexion basse tension Type de batterie Mi
58. ria e controlador seja a menor poss vel Observe que os terminais positivos do controlador CMLsolid 30 s o conectados internamente entre si e por isso t m o mesmo potencial el trico Caso seja necess rio uma conex o de aterramento ent o sempre utilize os terminais condutores positivos para este fim O gabinete ro do controlador de charga podera ser aterrado atwaves de um terminal dedicado disponivel para esta fun o OBSERVACOES Caso o controlador de carga seja utilizado em veiculo cujo polo negativo da bateria esteja conectado ao chassis ent o as cargas conectadas ao controlador de carga nao poder o ter conex o el trica com o chassis consumidores do veiculo Caso contr rio ocorrera um curto circuito danificado a fung o Desconex o por Baixa Tens o LVD da prote o eletr nica do controlador OBSERVA ES Siga as recomenda es do fabricante da bateria Recomendamos veementemente conectar um fus vel de prote o diretamente ao polo da bateria a fim de evitar quaisquer riscos a estes condutores O fus vel deve ser compat vel com a corrente nominal do controlador de carga recomendamos no m ximo a capacidade nominal de 45 A 79 Terminal para aterramento CIML sona e Terminal phocos it Contato para controle de inversores Conector 80 USB Inicializa o do controlador Autoteste Assim que a bateria tiver sido
59. rray does not supply electricity Green LED on Green LED off State of charge display gt 75 25 75 lt 25 lt 10 3 Yellow LEDs on 2 Yellow LEDs on 1 Yellow LED on 1 Yellow LED flashes The percentage corresponds to the available energy until Low Voltage Disconnect with respect to a fully charged battery 26 Acoustic signals A change in the state of charge SOC to a lower status is indicated by an acoustic signal The loads are disconnected approx 1 minute after a series of 25 tones Load status display In case of deep discharge or overload short circuit of load the load output is switched off This is indicated by H m ms m nn D 2 x X BX x SS Normal operation Low voltage disconnect Overload or Short circuit of load Red LED off Red LEDon Red LED flashing 27 Low Voltage Disconnect Function The controller has 2 different modes to protect the battery from being deeply discharged 1 State of charge controlled Disconnect at 11 4 V 22 8 V at nominal load current up to 11 9 V 23 8 V at no load current Normal operation mode for safe battery protection 2 Voltage controlled Disconnect at 11 0 V 22 0 V fixed setting Appropriate if bypass loads draw current directly from the battery The controller is preset to Mode 1 from the factory Changing the mode setting is described below Settings The controller can be configured
60. s o carga rapida 14 4 28 8 V 25 C 2h Nivel de tens o conex o do consumidor Tens o da bateria lt 12 3 24 6 V Nivel de tens o equaliza o Nivel de tens o equaliza o 14 8 29 6 V 25 C 2 h Atua o da equaliza o Tens o da bateria lt 12 1 24 2 V ao menos uma vez a cada 30 dias Ativac o da protec o contra sobretens o 15 5 31 0V Ativa o da prote o contra descarga profunda 11 4 11 9 22 8 23 8 V estado controlado por SOC 92 Tens o de corte desconex o por sub tens o 11 0 22 0 V estado controlado por tens o Reconex o niveis de tens o 12 8 25 6V Prote o contra sub tens o 10 5 21 0V Tens o maxima de painel 50V Tens o m xima de bateria 50V Compensag o de temperatura Tens o de carga 4 2 mV K por celula da bateria Autoconsumo repouso lt 10 mA Condutor terra Positivo aterrado Baixa de temperatura armazenagem 40 50 C Altitude m x 4 000 m acima do nivel do mar Tipos de bateria Chumbo cida GEL AGM Liquida Dimens es LXAXP 140 x 90 x 40 mm Peso 420g Se o maxima condutor 16 mm Grau de prote o tipo IP20 93 Vide gr fico da SOA Area de prote o segura CMLsolid 30 SOA 160 140 120 100 Corrente nominal pa nel solar 0 2 40 6 80 100 120 140 160 Corrente nominal consumidor
61. s sobre manuten o e instala o Antes de instalar ou colocar o sistema fotovoltaico em funcionamento desconecte os pain is FV solares do controlador a fim de prevenir qualquer dano ao controlador de carga Verifique se todos os condutores e cabos de conex o est o bem conectados aos terminais a fim de evitar mau contato ou conex es soltas que possam levar a um sobreaquecimento Instale por favor o fus vel ou disjuntor pr ximo bateria antes de iniciar a instala o ou ajustes do controlador Instale e utilize o controlador em lugar seco Perigo de tens o elevada A utiliza o deste dispositivo pode produzir tens es elevadas o que pode causar graves danos ou at a acidentes fatais em caso de instala o ou utiliza o indevida Os pain is fotovoltaicos podem gerar tens o elevada em corrente cont nua CC Assegure se que os condutores estejam sempre conectados ao terminal correto Um choque el trico por utiliza o indevida do equipamento pode ser letal Choques el tricos de modo geral podem ser perigosos para a sua sa de 77 Marcag o CE O produto est conforme para utiliza o da marca CE Descri o das fun es m O controlador de carga protege a bateria de sobrecargas do painel solar e de descargas profundas pelos consumidores As caracter sticas de carga incluem v rios est gios de carga dentre eles o ajuste autom tica temperatura ambiente O controlador de carga se ajusta automaticamen
62. se en marche Alarme allum e Etat de charge v rifi GEL batterie VRLA Arr t Alarme teinte Tension v rifi e Batterie ouverte Param trage d usine Alarme allum e Etat de charge v rifi GEL batterie VRLA Dispositifs de s curit Bornes des panneaux solaires Bornes de batterie Bornes des charges Polarit invers e Prot g es Avertissement LED rouge allum e 1 Prot g es 1 Court circuit Prot g es 2 Prot g es 3 Prot g es 2 Surintensit Extinction apr s un laps de temps 4 Courant inverse Prot g es 67 Bornes ses Panneaux Bornes de batterie Bornes des charges solaires Surtension 50 V maxi 50 V maxi Extinction partir de 15 5 V 31 0V Sous tension Extinction Surchauffe R duction du courant de charge en cas de surchauffe et extinction des charges si la temp rature atteint un niveau lev 1 Le r gulateur est quip d un dispositif d autoprotection mais les charges branch es peuvent tre endommag es 2 Court circuit Protection lectronique contre les surintensit s limit e lt 400 A 3 La batterie doit tre de court circuit prot g e par un fusible pour ne pas tre d finitivement endommag e en cas 4 gt 200 du courant nominal d connexion au bout de 3 secondes AVERTISSEMENT La combinaison de di
63. t aboutir une surchauffe Veuillez galement installer un fusible ou un disjoncteur pr s de la batterie avant d installer ou r gler l appareil Le r gulateur doit tre install et utilis uniquement dans un endroit sec Risques li s la haute tension Le fonctionnement du r gulateur de charge peut g n rer une haute tension pouvant causer des blessures graves voire mortelles en cas d installation ou d utilisation non conforme de l appareil Les panneaux photovolta ques peuvent g n rer des tensions continues lev es V rifiez que tous les c bles soient toujours correctement raccord s aux bornes pr vues Une d charge lectrique peut entra ner la mort De mani re g n rale toute d charge lectrique pr sente un risque pour votre sant 58 Marquage CE Le present produit est conforme aux normes CE Description des fonctions m Le r gulateur de charge prot ge la batterie contre les risques de surcharge lies aux panneaux solaires et de d charge profonde li e aux charges Le processus de chargement s effectue en plusieurs tapes qui incluent l adaptation automatique la temp rature ambiante Le r gulateur de charge s ajuste automatiquement la tension du syst me en 12 V ou 24V Le r gulateur de charge est quip de nombreuses fonctions de s curit et d affichage Branchement et mise la terre Le r gulateur de charge doit imp rativement tre install l int rieur l abri de l
64. tamente a la bater a para protejer el cableado de la misma El fusible debe estar de acuerdo con la corriente nominal del controlador de carga 45 A Activar el controlador Test autom tico En cuanto el controlador recibe corriente ya sea de una bater a o de un m dulo solar se activa un test autom tico rutinario A continuaci n la visualizaci n cambia a funcionamiento normal Voltaje del sistema El controlador de carga se ajusta autom ticamente al sistema de voltaje de 12 V o 24 V Si durante el encendido el voltaje excede de 18 0 V el controlador cambia a un sistema de 24 V Si durante el encendido el voltaje de la bater a no est dentro de la escala normal de funcionamiento se muestra un MENSAJE DE ERROR 42 Tipo de bateria El controlador est programado para funcionar con baterias de plomo con electrolito s lido tipo GEL o tipo AGM Si piensa usar la bateria de plomo con electrolito liquido puede ajustar las caracter sticas de carga v ase Configuraci n En ese caso se activar la carga de ecualizaci n Si tiene alguna duda consulte con el vendedor Recomendaciones de uso El controlador se calienta mientras est en funcionamiento El controlador no requiere ningun mantenimiento o revisi n Retire el polvo con un pa o seco Es importante que la bateria se cargue completamente con frecuencia al menos una vez al mes De otro modo la bateria estara permanentemente da ada Una bateria sol
65. te a sistemas com tens o de 12V ou 24V O controlador de carga tamb m a presenta uma s rie de sinaliza es na sua face frontal Montagem e apresenta O controlador foi projetado apenas para uso interno Instale controlador em lugar seco e abrigado da luz do sol Nunca instale o controlador em recintos midos como banheiros por exemplo O controlador mede a temperatura ambiente para determinar a tens o de carga da bateria Tanto o controlador como a bateria devem ser instalados num mesmo local O controlador se aquece quando em funcionamento por isso deve ser afixado sobre uma superf cie de material n o inflam vel Objetivando evitar problemas de instala o m Por gentileza observar a seguinte sequencia de conex o ao colocar o sistema em funcionamento 1 Conecte a bateria ao controlador de carga terminais positivo e negativo 2 Conecte os pain is fotovoltaicos ao controlador de carga terminais positivo e negativo 3 Conecte a carga consumidor ao controlador positivo e negativo Siga o procedimento inverso caso necessite desinstalar 78 m Para evitar qualquer tens o indesejada nos condutores conecte primeiro os condutores ao controlador depois bateria e depois aos pain is fotovoltaicos No caso do consumidor carga conecte primeiro s condutores carga e depois ao controlador E Se o m nima recomendada para os condutores 10 mm Assegure se que a dist ncia de instala o entre bate
66. ur de charge soit le plus court possible m V rifiez que les bornes positives du r gulateur CMLsolid 30 soient raccord es entre elles et par cons quent qu elles aient le m me potentiel lectrique Si une mise terre est requise elle doit toujours tre effectu e sur les fils positifs Une borne de mise la terre pr vue cet effet permet de relier le bo tier du r gulateur de charge la terre NOTE si le dispositif est utilis dans un v hicule dont le ch ssis est quip d une batterie n gative les charges raccord es au r gulateur ne doivent pas tre en contact lectrique avec la carrosserie de la voiture Dans le cas contraire la fonction de d connexion basse tension et celle du fusible du r gulateur seraient court circuit es NOTE prenez en compte les recommandations du fabricant de votre batterie Nous recommandons vivement de brancher un fusible directement sur la batterie afin d viter tout court circuit au niveau du c blage de celle ci Le fusible utilis doit tre adapt au courant nominal du r gulateur de charge savoir 45 A 60 Borne de mise ala terre CMUsoio phoco Borne de ontr le a G gt distance de l onduleur Fusible o amp 61 Port USB Mise en marche du r gulateur de charge solaire Autocontr le Des que le r gulateur est aliment par la batteri
67. ura Si o LED rojo parpadea autom ticamente el No se x consumo despu s de suministran max 1 minuto Compruebe que otras los consumos fuentes no est n sobrecargando la bateria De otro modo se da ar el controlador El voltaje de la bateria es demasiado alto gt 15 5 31 0V Los cables o el fusible de la R 2 Compruebe los cables y bater a est n da ados la E S Ge fusibles de la bateria y el bateria tiene una S E a estado de la misma resistencia elveada 51 Error Visualizaci n de errores Causa Soluci n La bateria se vacia despu s de poco tiempo La bateria tiene baja capacidad LED rojo encendido Cambie la bateria La bateria no se carga durante el dia M dulo solar defectuoso o polaridad equivocada LED verde apagado Corrija la conexi n defectuosa polaridad inversa Bater a con polaridad equivocada La bateria est conectada con polaridad inversa LED rojo encendido Corrija la polaridad inversa de la bateria 52 Datos t cnicos Nota Los niveles de voltaje antes despu s de la barra son v lidos para sistemas de 12 V y de 24 V respectivamente Datos t cnicos CMLsolid 30 Voltaje del sistema 12 24 V autoreconocimiento Corriente de carga max 30 A Corriente de consumo max 30 A Carga de flotaci n 13 8 27 6V 25 C Carga principal 14
68. vent tre scrupuleusement suivies lors de l installation et l entretien du r gulateur de charge RISQUE D INCENDIE UTILISER LE R GULATEUR 0 5 m DE DISTANCE DES BATTERIES Type de batterie plomb acide GEL AGM ouverte Tension nominale de la batterie 12 V ou 24V 57 Fusible de la batterie utilisez un fusible a action rapide avec une valeur de coupure minimale de 1000A du c t de la batterie Nous recommandons l utilisation d un fusible action rapide fusibles pour voitures par exemple a installer le plus pres possible du bornier de la batterie Le courant nominal doit correspondre au maximum a 1 5 fois le courant nominal du r gulateur de charge Veuillez ne pas d monter ni essayer de r parer par vous m me un produit Phocos Les r gulateurs de charge Phocos ne contiennent aucune pi ce pouvant tre r par e par l utilisateur Veillez en outre respecter scrupuleusement toutes les instructions qui concernent les fusibles et les disjoncteurs externes Remarques concernant l entretien et l installation Lors de l installation ou d op rations effectu es sur le syst me photovolta que veillez d brancher les panneaux photovolta ques du r gulateur de charge afin d viter tout endommagement du r gulateur Veuillez galement v rifier que tous les raccordements de c bles et de fils sont suffisamment serr s au niveau des bornes de connexion pour viter de mauvaises connexions ou des connexions desserr es pouvan