1.                                                                                        Dati tecnici Technical data  Motori trifase serie TS   TS Series three phase motors  230 400 V   50 Hz   3000 min   poli   poles 2  TS  561 2 0 09 0 32 2710 0 36 53 0 72 2 2 4 2 3 2 58 2 6  562 2 0 12 0 42 2700 0 40 61 0 72 2 2 4 2 3 2 58 3 0  631 2 0 18 0 63 2710 0 55 63 0 75 2 2 6 2 4 1 6 61 4 0  632 2 0 25 0 88 2710 0 71 65 0 78 2 2 6 2 4 1 6 61 4 2  633 2 0 37 1 30 2710 1 05 65 0 78 2 2 6 2 4 1 6 62 4 7  711 2 0 37 1 29 2730 0 97 70 0 79 2 2 6 2 4 1 6 64 5 2  712 2 0 55 1 90 2760 1 42 71 0 79 2 2 6 2 4 1 6 64 6 0  713 2 0 75 2 62 2730 1 83 72 0 82 2 2 6 2 4 1 5 65 7 0  801 2 0 75 2 58 2770 1 77 73 0 84 2 2 6 2 4 1 5 67 8 7  802 2 1 1 3 79 2770 2 51 76 2 0 83 2 2 6 2 4 1 5 67 10 0  803 2 1 5 5 11 2800 3 32 78 5 0 83 2 2 6 2 4 1 5 70 11 2  90S 2 1 5 5 04 2840 3 28 78 5 0 84 2 2 6 2 4 1 5 72 12 0  90L1 2 2 2 7 40 2840 4 61 81 0 85 2 2 6 2 4 1 4 72 14 5  90L2 2 3 10 1 2840 6 10 82 6 0 86 2 2 6 2 4 1 4 74 15 0  100L1 2 3 10 1 2840 6 03 82 6 0 87 2 2 7 2 3 1 4 76 20 0  100L2 2 4 13 4 2850 7 88 84 2 0 87 2 2 7 5 2 3 1 4 77 24 0  112M 2 4 13 3 2880 7 88 84 2 0 87 2 2 7 5 2 3 1 4 77 26 0  112L 2 5 5 18 2 2880 10 5 85 7 0 88 2 2 7 5 2 3 1 2 78 29 3  132S1 2 5 5 18 1 2900 10 5 85 7 0 88 2 7 5 2 2 1 2 80 38 4  132S2 2 7 5 24 5 2920 14 1 87 0 88 2 7 5 2 2 1 2 80 41 3  132M1 2 9 2 30 0 2930 17 3 88 0 89 2 7 5 2 2 1 2 81 48 2  132M2 2 11 35 9 2930 20 0 88 4 0 9 2 7 5 2 2 1 2 83 52 5  160M1 2 11 35 7 2
2.                                                                        TS  56 9 20   M3   10 2  3   120  100   80 7 3   117   100   88   1 M16x1 5   196 88   14  63 11   28   M4   125   4   140   115   95   10 3   130   108   94   1 M16x1 5   220 94   14  711 2 3   14   30   M5   16 5   160   130   110   10   3 5   147   115   94   1 M20x1 5  241  255   94   20  80 19   40   M6   215  6   200   165   130   12   3 5   163   133   105   1 M20x1 5  290   105   27  90S 24   50   M8   27 8   200   165   130   12   3 5   183   139   105   1 M20x1 5  312   105   30  90L1 L2   24   50   M8   27 8   200   165   130   12   3 5   183   139   105   1 M20x1 5   337 367   105   30  100L 1 2 3   28   60   M10   31 8  250   215   180   15 4   205   152   105   2 M20x1 5  369  387  105   26  112 28   60   MIO   31 8   250   215   180   15 4   229   167   112   2 M25x1 5  395   112   32  132S 38   80   M12  41   10   300   265   230   15 4   265   186   112  2 M25x1 5  437   112   38  132M L 38   80   M12  41   10   300   265   230   15 4   265   186   112   2 M25x1 5   475 501   112   38  160M L   42   110   M16   45   12   350   300   250   19 5   325   224   143   2 M32x1 5   640   143   64  Dimensioni motori trifase serie TS B1 4 TS Series three phase motors dimensions   TS  56 9 20   M3   10 2  3 80   65   50   M5   25   117   100   88   1 M16x1 5  196 88   14  63 11   23   M4 125 4 90   75   60   M5   2 5   130   108   94   1 M16x1 5  220 94   14  711 2 3   14   30   M5   16 5   105  85 
3.      More detailed    COMMISSION REGULATION  EC  No 640 2009 of 22 July 2009  implementing Directive 2005 32 EC of the European Parliament  and of the Council with regard to ecodesign requirements for elec   tric motors    are meaning to be applied to    Electric Motor single speed  three phase 50 Hz or 50 60 Hz  squir   rel cage induction motor that has 2 to 6 poles  rated voltage up to  1000V  has a rated output between 0 75 kW and 375 kW  is rated  on the basis of continuous duty operation    from 16 June 2011   motors shall not be less efficient than the IE2 efficiency level     Following years will come into force higher efficiency levels elec   tric motors   Available also IE3 and MEPS2  Australia  motors    Pls  contact Transtecno to have quotation and tech details        Motore  Motor          2  4   6 poli   poles   lt  1000 V 50  60  50 60 Hz  0 75 kW  lt  Motor  lt  375 kW S1          Part 2   Informazioni generali   General informations       E LL       Lista dei componenti TS TS spare parts list                Corpo motore B3   Frame B3  Corpo motore B5 B14   Frame B5 B14  Statore   Wound stator                Albero   motore   Rotor with shaft          Scudo anteriore   Front shield       Cuscinetti   Bearings  Chiavetta   Key  Scudo posteriore   Back shield             Etichetta   Nameplate       Anello di tenuta   Spring washer  Viti e dadi   Rods and nuts  Ventola   Cooling fan             Seeger ventola   Fan circlip       Paraolio   Rubber seal ring       C
4.     20   Pressacavo   Cable gland       21   Scatola morsettiera   Terminal box  base        22   Coperchio scatola morsettiera   Terminal box  cover        23   Condensatore   Run capacitor       24   Viti scudi   Mounting studs screws   25   Flangia B5   Flange B5   26   Flangia B14   Flange B14   27   Viti coperchio   Screws for terminal box fixing                         Part 2   Informazioni generali   General informations                                                                0    l          
5.    Coppia   torque    invariata   the same  Potenza   power     20              In realt   fenomeni quali la saturazione del flusso magnetico nel  ferro  perdite per rotolamento  non linearit    ecc  modificano l ef   ficienza complessiva e si possono ottenere scostamenti del dato  teorico che quindi    da intendersi come indicazione  Per valori  precisi  si prega di contattare Transtecno s r l     Grafico motore TS 8024 nelle 2 configurazioni  400 V 50 Hz   480 V 60 Hz       Coppia   Torque Potenza   Power   Nm   kW   12 0   72 0  11 0  11 8   9 0   r1 4   8 04  7 0   12  6 04 r1 0  5 0  p 108  4 0  los  3 0   A   204 i   1 0    02  0 0 0             0 200 400 600 800 1000 1200 1400 1600  Giri   Speed  rpm     In practice  iron saturation of magnetic flux  volving losses  non  linearity phenomena  etc  vary the global efficiency with shifting  from theorical data  which are to be intended just as an indica   tion   Pls  contact Transtecno s r l  for more exact data     Motor TS 8024 performance diagram  both configurations  400 V 50 Hz   480 V 60 Hz                Coppia   Torque Potenza   Power   Nm   kW   1204 120  11 04 11 8  10 0 4 116  9 04   1 4  8 04  7 0    1 2  6 0      1 0  501 10 8  4 0   los  3 04 T  2 041    1 01 102  ol   0 0  0 500 1000 1500 2000    Giri   Speed  rpm     Part 2   Informazioni generali   General informations       E ML       Linee guida di montaggio    Mounting guidelines       Avvertenze per il corretto e sicuro uso dei motori  Si consiglia di
6.    a A oa gio w m m UO E  5624 0 09 0 64 1340 0 87 55 0 9 0 65 2 0 1 6 0 60 6 3 4  6324 0 18 1 26 1360 1 54 60 0 9 0 55 2 7 1 7 0 50 8 3 4  7124 0 37 2 58 1370 3 68 0 92 0 50 3 2 1 6 0 45 16 7 0  8024 0 75 5 20 1380 5 5 73 0 92 0 55 3 2 1 6 0 50 30 11 5                                              Legenda  vedere pagina 3    Key  read page 3    Dimensioni motori monofase serie MY    B5    MY Series single phase motors dimensions                                                        wv  x   ao   e  Jr ja   e  56 110 90 124 84 9 M4x12 20 3  63 121 90 124 84 11 M4x12 23 4  71 138 110 128 84 14 M5x12 30 5  80 159 152 128 60 19 M6x16 40 6     wy  ow  os      Jose             e   56 2 M18x1 5 192 100 80 120 7 3 10 2  63 2 M18x1 5 214 115 95 140 9 3 12 5  71 2 M18x1 5 250 130 110 160 9 3 5 16  80 2 M20x1 5 284 165 130 200 12 3 5 21 5       Dimensioni motori monofase serie MY    B14    MY Series single phase motors dimensions                                                       MY  56 110 90 124 84 9 M4x12 20 3  63 121 90 124 84 11 M4x12 23 4  71 138 110 128 84 14 M5x12 30 5  80 159 152 128 60 19 M6x16 40 6  56 2 M18x1 5 192 65 50 80 M5 3 10 2  63 2 M18x1 5 214 75 60 90 M5 3 12 5  71 2 M18x1 5 250 85 70 105 M6 3 5 16  80 2 M20x1 5 284 100 80 120 M6 3 5 21 5                   MOTORI ELETTRICI TS  MY a   Dati tecnici         Technical data  Dimensioni motori monofase serie MY    MY Series single phase motors dimensions          morsettiera  terminal box    56 63 71             morset
7.   70   MG   2 5   147   115   94   1 M20x1 5  241  255  94   20  80 19   40   M6 215  6   120  100   so   MG   3   163   133   105   1 M20x1 5  290   105   27  90S 24   50   M8   27 8   140   115   95   M8   3   183   139   105   1 M20x1 5  312   105   30  90L1 L2   24   50   M8   27 8   140   115   95   M8   3   183   139   105   1 M20x1 5   337 367   105   30  100L 1 2  3  28   60   M10   31 8   160   130   110   M8   3 5   205   152   105   2 M20x1 5  369  387  105   26  112 28   60  M10   31 8   160   130   110   M8   3 5   229   167   112   2 M25x1 5  395   112   32  132S 38   80   M12  41   10   200   165   130   MO   4   265   186   112   2 M25x1 5  437   112   38  132M L 38   80   M12   41   10   200   165   130   M10 265   186   112   2 M25x1 5   475 501   112   38  160M L   42   110   M16   45   12   250   215   180   M12 325   224   143   2 M32x1 5  640   143   64  Dimensioni motori trifase serie TS B3 TS Series three phase motors dimensions   TS  56 9   20   M3 102 3   56   36   71   90   110  5 8x8 8  6 5   117   100  88  1 M16x1 5  196   88   14  63 11   23   M4  125  4   63   40   80  100  120   7x10   7   130   108  94  1 M16x1 5  220   94   14  71 14   30   M5  16   5   71   45   90  112  132   7x10   10   147  115 94  1 M20x1 5  255  94   20  80 19   40   M6 215 6   80   50   100   125  160   10x13   10   163   133   105  1 M20x1 5  290   105  27  90S 24   50   M8   27   8   90   56   100   140 175   10x13   12   183   139   105   1 M20x1 5  312   105  30  9
8.  4 74 56 5  132L2 4 11 71 9 1460 20 9 88 4 0 86 2 2 7 5 2 2 1 4 74 64 0  160M 4 11 71 9 1460 20 6 88 4 0 87 2 2 7 2 2 1 4 75 73 0  160L1 4 15 98 1 1460 28 2 88 4 0 87 2 2 7 5 2 2 1 4 75 88 5  160L2 4 18 5 121 0 1460 34 7 90 5 0 85 2 2 7 5 2 2 1 4 78 97 5                                                 Legenda  vedere pagina 3  Key  read page 3    MOTORI ELETTRIC T    My Y                                                                                                                                                 Dati tecnici Technical data  Motori trifase serie TS   TS Series three phase motors  230 400 V   50 Hz   1000 min     poli   poles 6  TS  631 6 0 09 1 02 840 0 51 42 0 61 2 3 5 2 1 5 50 4 2  632 6 0 12 1 35 850 0 62 45 0 62 2 3 5 2 1 5 50 4 5  711 6 0 18 1 95 880 0 70 56 0 66 1 6 4 1 7 1 5 52 5 6  712 6 0 25 2 65 900 0 87 59 0 7 2 1 4 2 2 1 5 52 6 0  713 6 0 37 3 97 890 1 27 61 0 69 2 4 2 1 1 5 54 6 8  801 6 0 37 3 93 900 1 23 62 0 7 1 9 4 1 9 1 5 56 8 1  802 6 0 55 5 84 900 1 65 67 0 72 2 4 2 3 1 5 56 9 6  803 6 0 75 7 96 900 2 21 68 0 72 2 4 2 3 1 5 58 10 0  90S 6 0 75 7 78 920 2 18 69 0 72 2 2 5 5 2 2 1 5 59 11 3  90L1 6 1 1 11 4 925 3 02 72 0 73 2 2 5 5 2 2 1 3 59 14 4  100L1 6 1 5 15 1 945 3 85 74 0 76 2 2 6 2 2 1 3 61 18 8  112M 6 2 2 22 0 955 5 36 78 0 76 2 2 6 2 2 1 3 64 25 0  132S 6 3 29 8 960 7 21 79 0 76 2 6 5 2 1 3 64 35 0  132M1 6 4 39 8 960 9 44 80 5 0 76 2 6 5 2 1 3 68 47 6  132M2 6 5 5 54 7 960 12 4 83 0 77 2 6 5 2 1 3 68 50 7  132L 6 7 5 74 6 960 16 
9.  B7   IM 1071  B8                                                                                                                                                                                                                                                                                            IM 3001  B5                             IM 3031  V3                                                                                                                                                                                                                                                                                                                                   IM 3601  B14           IM 3611  V18  IM 3631  V19        B3 B5 B14                                                                                                                                                                                                                                                                                        IM 2001  B3 B5  IM 2101  B3 B14  IM 2011  V15  IM 2031  V36    B3   B14 B5   B3   B14 B5     Part 2   Informazioni generali   General informations    MOTORI ELETTRICI TS  MY    D  D       Grado di protezione IP    IP enclosures protection indexes       Indica il grado di isolamento meccanico del corpo motore   12 cifra protezione alla penetrazione di corpi solidi     2  cifra protezione contro la penetrazione d acqua     Indicates the degree of mechanical insulation of the m
10.  affidare l installazione  uso e manutenzione del mo   tore elettrico a personale esperto e qualificato     I consigli di seguito riportati non annullano la necessit   al  buon senso e alla prudenza in ogni applicazione e comunque  non sostituiscono le imposizioni delle normative vigenti nei  campi di applicazione     Alla ricezione   verificare eventuali danni all albero  copri ventola e carcassa pri   ma della installazione  Controllare i valori di targa del motore  Non  utilizzare se i dati non sono conformi alle esigenze  tensione  fre   quenze  coppia  grado di protezione IP  velocit    servizio termi   co     Se necessario immagazzinare  tenere il motore in ambiente  asciutto e pulito     Avviamento   Fissare in maniera sicura ed adeguata il motore    La parti meccaniche esposte e soprattutto gli organi rotanti van   no adeguatamente protette dal contatto con persone  animali e  cose    Collegare il contatto di terra del motore alla linea di terra o al si   stema di protezione    Non alimentare il motore con la chiavetta non fissata  potrebbe  sfuggire e colpire persone ed oggetti    Segnalare adeguatamente il senso di rotazione laddove possa  arrecare danni     E  consigliata protezione adeguata sulla sovracorrente  ad esem   pio tramite un rel   termico che comandi un sezionatore di potenza    fusibili e i dispositivi di protezione devono essere tarati per un  valore inferiore alla corrente di rotore bloccato     La serie MY    fornita con PTO standard per la protezio
11.  termico di classe F  e Grado di protezione IP55    e Sonda bimetallica PTO per protezione da sovratemperatura   solo MY     e Rumorosit   e vibrazioni contenute  e Temperatura ambiente   20   C    40   C     e   motori della serie MY si caratterizzano per I    ampia coprimor   settiera dove il condensatore di marcia trova alloggiamento e  protezione    e Per uso industriale  industria leggera e pesante  e commer   ciale     Designazione    TS and MY series motors are closed and fan cooled     TS series includes induction threephase 2 4 6 8 poles motors  230 400 Vac at 50 Hz and 275 480 Vac at 60 Hz  it covers power  sizes from 0 06 kW up to 18 5 kW  These motors run quietly and  are dinamically well balanced  they match quality  strength and  cheapness     MY series includes induction singlephase motors 230 Vac at 50  Hz and covers power sizes from 0 09 kW up to 0 75 kW    they are particular suitable to be mounted on machine for low po   wer applications  As well as TS series motors  they match quality  and cheapness    Both series are made in aluminum frame and are available with  B5 or B14 flange mountings  B3 only for TS     Standard features are     e Class F thermal insulation  e  P55 enclosure protection  e PTO thermostat for overheating protection  only MY     e Low noise and vibrations  e Ambient temperature   20   C    40   C     e MY series motors have a large terminal box  which includes the  run capacitor  in order to protect it from external environment     e H
12. 0L1 L2   24   50   M8   27   8   90   56   125   140   175   10x13   12   183   139   105   1 M20x1 5   337 367   105   30  100L 1 2 3   28   60  M10  31   8  100  63   140   160 198   12x15   14   205   152   105  2 M20x1 5  369  387  105   26  112 28   60  M10  31   8 112 70   140  190 220 12x15   14   229   167   112  2 M25x1 5  395  112  32  132S 38   so M12  41   10  132  89   140  2146   252   12x15   16   265   186   112  2 M25x1 5  437  112   38  132M L   38   80 M12  41   10  132  89   178  2146   252   12x15   16   265   186   112  2 M25x1 5   475 501   112   38  160M L   42   110 M16  45   12  160   108 210 254 254   290   15x19   16   325   224   143  2 M32x1 5  640  143  64   Part 1   Dati   Data                Dati tecnici Technical data       Dimensioni motori trifase serie TS B5 TS Series three phase motors dimensions                      F  DH    Sa  o   oD                                        Dimensioni motori trifase serie TS B1 4                                                                                                                                                                         F  DH   lt        2D  Dimensioni motori trifase serie TS B3 TS Series three phase motors dimensions       F      DH     D    s  9                                                           gt   TS  MY MOTORI ELETTRICI       Dati tecnici Technical data  Motore monofase serie MY  MY Series single phase motors  230 V   50 Hz   1500 min   poli   poles 4             omo
13. 17  Lista dei componenti TS TS spare parts list 18  Lista dei componenti MY MY spare parts list 18    Questa sezione annulla e sostituisce ogni precedente edizione o revi  This section replaces any previous edition and revision  If you obtained  sione  Qualora questa sezione non Vi sia giunta in distribuzione con  this catalogue other than through controlled distribution channels  the  trollata  l aggiornamento dei dati ivi contenuto non    assicurato  In tal most up to date content is not guaranteed  In this case the latest ver   caso la versione pi   aggiornata    disponibile sul nostro sito inter  sion is available on our web site www transtecno com   net www transtecno com    0710       E LL       Caratteristiche tecniche    Technical characteristics         motori della serie TS e MY sono chiusi e dotati di ventola di  raffreddamento    La serie TS comprende motori ad induzione trifase 230 400 Vca  a 50 Hz e 275 480 Vca a 60 Hz  2 4 6 8 poli  per potenze da 0 06  kW fino a 18 5 kW  silenziosi e dinamicamente ben bilanciati  uniscono qualit   robustezza e convenienza     La serie MY comprende motori ad induzione monofase 230 Vca  50 Hz  per potenze da 0 09 kW fino a 0 75 kW  adatti per uso con  macchine che necessitano di potenze ridotte    Anch essi uniscono qualit   e convenienza     Entrambe le serie sono costruite in alluminio e sono disponibili in  configurazione B5 oppure B14  B3 solo per TS     Altre caratteristiche standard dei motori TS   MY sono     e Isolamento
14. 5 1 M16x1 5  63 6201 2RZ 6201 2RZ 12x24x5 1 M16x1 5  71 6202 2RZ 6202 2RZ 15x25x7 1 M20x1 5  80 6204 2RZ 6204 2RZ 20x34x7 1 M20x1 5  90 6205 2RZ 6205 2RZ 25x37x7 1 M20x1 5  100 6206 2RZ 6206 2RZ 30x44x7 2 M20x1 5  112 6306 2RZ 6206 2RZ 30x44x7 2 M25x1 5  132 6308 2RZ 6208 2RZ 40x58x7 2 M25x1 5  160 6309 2RZ 6309 2RZ 45x65x8 2 M32x1 5  MY  56 6201ZZ C3 6201ZZ C3 12x22x5 2 M18x1 5  63 6201ZZ C3 6201ZZ C3 12x22x7 2 M18x1 5  71 6202ZZ C3 6202ZZ C3 15x25x7 2 M18x1 5  80 6204ZZ C3 6204ZZ C3 20x30x7 2 M20x1 5                Part 2   Informazioni generali   General informations       Connessioni e collegamenti    MOTORI ELETTRICI TS  MY a 2     Connection diagram       TS   230 V   50 Hz  275 V 60Hz    400 V   50 Hz  480 V 60Hz     w2 U2 V2  OOO    Nota  per invertire il senso di rotazione spostare tra loro 2 cavi  Note  swap each other 2 leads to reverse rotation       A richiesta  sopra i 3 kW disponibile alimentazione 400 V  triangolo    690  V  stella      Protezione termica bimetallica  PTO    solo MY    MY   230 V   50 Hz    Senso di rotazione antiorario   vs ventola   Counterclockwise rotation  vs fan     Senso di rotazione orario   vs ventola   Clockwise rotation  vs fan     Over 3 KW size motors available 400 V  delta    690 V  star   Supply  voltage version on request     Thermal bimetallic protector  PTO    only MY       La serie MY    dotata di pastiglia termica bimetallica  PTO  per il  monitoraggio del superamento della soglia termica  135  C   5  C    Utile per uso tal
15. 5 85 0 77 2 6 5 2 1 3 68 47 6  160M 6 7 5 74 6 960 15 7 86 0 8 2 6 5 2 2 1 3 68 70 0  160L 6 11 109 4 960 23 0 87 5 0 79 2 6 5 2 2 1 2 73 87 0  Motori trifase serie TS   TS Series three phase motors  230 400 V   50 Hz   750 min     poli   poles 8  TS  711 8 0 09 1 26 680 0 48 48 0 56 1 5 3 1 7 1 3 50 5 6  712 8 0 12 1 66 690 0 58 51 0 59 1 6 2 7 1 7 1 3 50 6 0  801 8 0 18 2 52 680 0 84 51 0 61 1 5 2 8 1 7 1 3 52 9 4  802 8 0 25 3 51 680 1 06 56 0 61 1 6 2 7 2 1 3 52 10 1  90S 8 0 37 5 19 680 1 35 63 0 63 1 6 2 8 1 8 1 3 56 12 5  90L 8 0 55 7 72 680 1 85 66 0 65 1 6 3 1 8 1 3 56 15 3  100L1 8 0 75 10 1 710 2 45 66 0 67 1 7 3 5 2 1 1 3 59 17 2  100L2 8 1 1 14 8 710 3 20 72 0 69 1 7 3 5 2 1 1 2 59 19 5  112M 8 1 5 20 2 710 4 30 74 0 68 1 8 4 2 2 1 1 2 61 25 5  132S 8 2 2 29 2 720 5 96 75 0 71 2 5 5 2 1 2 64 34 2  132M 8 3 39 8 720 7 70 77 0 73 2 5 5 2 1 2 64 40 0  160M1 8 4 52 3 730 9 89 80 0 73 1 9 6 2 1 1 2 68 59 0  160M2 8 5 5 72 9 720 12 9 83 5 0 74 2 6 2 2 1 2 68 69 0  160L 8 7 5 99 4 720 17 0 85 0 75 1 9 6 2 2 1 2 68 87 0                                                 Legenda  vedere pagina 3  Key  read page 3          Dati tecnici    SI TS  y Morori eera    T    Technical data       Dimensioni motori trifase serie 1 S    B5    TS Series three phase motors dimensions                                                                                                                                                                                                                 
16. 940 20 0 88 4 0 9 2 7 5 2 2 1 2 86 76 0  160M2 2 15 48 7 2940 26 6 89 4 0 91 2 7 5 2 2 1 2 86 77 5  160L 2 18 5 60 1 2940 32 6 90 0 91 2 7 5 2 2 1 1 86 92 0  Motori trifase serie TS   TS Series three phase motors  230 400 V   50 Hz   1500 min   poli   poles 4  TS  561 4 0 06 0 42 1360 0 35 50 0 56 2 3 4 24 2 50 2 9  562 4 0 09 0 63 1360 0 45 52 0 59 2 3 4 2 4 2 50 3 2  631 4 0 12 0 84 1360 0 55 52 0 64 2 2 4 2 4 2 52 3 7  632 4 0 18 1 31 1310 0 70 57 0 65 2 2 4 2 4 2 52 4 2  633 4 0 25 1 78 1340 0 91 60 0 66 2 2 4 2 2 2 54 5 0  711 4 0 25 1 77 1350 0 84 60 0 72 2 2 6 2 4 1 7 55 5 0  712 4 0 37 2 58 1370 1 11 65 0 74 2 2 6 2 4 1 7 55 5 8  713 4 0 55 3 80 1380 1 60 66 0 75 2 2 6 2 4 1 7 57 6 5  801 4 0 55 3 83 1370 1 58 67 0 75 2 2 6 2 4 1 7 58 8 1  802 4 0 75 5 19 1380 1 93 72 0 78 2 2 6 2 4 1 6 58 9 1  803 4 1 1 7 55 1390 2 67 76 2 0 78 2 2 6 2 4 1 6 60 11 0  90S 4 1 1 7 50 1400 2 64 76 2 0 79 2 2 6 2 4 1 6 61 11 7  90L1 4 1 5 10 2 1400 3 45 78 5 0 8 2 2 6 2 4 1 6 61 14 4  90L2 4 2 2 15 0 1400 4 90 81 0 8 2 2 7 2 4 1 5 63 17 6  100L1 4 2 2 14 8 1420 4 84 81 0 81 2 2 7 2 3 1 5 64 19 2  100L2 4 3 20 2 1420 6 47 82 6 0 81 2 2 7 2 3 1 5 64 22 5  100L3 4 4 26 7 1430 8 36 84 2 0 82 2 2 7 2 3 1 5 65 27 3  112M 4 4 26 7 1430 8 26 84 2 0 83 2 2 7 2 2 1 5 65 29 0  112L 4 5 5 36 5 1440 11 2 85 7 0 83 2 2 7 2 2 1 4 68 35 7  132S 4 5 5 36 2 1450 11 0 85 7 0 84 2 2 7 2 2 1 4 71 39 0  132M 4 7 5 49 4 1450 14 6 87 0 85 2 2 7 2 2 1 4 71 48 6  132L1 4 9 2 60 2 1460 17 9 87 5 0 85 2 2 7 5 2 2 1
17. A C  ASYNCHRONOUS ELECTRIC MOTORS           TOCK PRODUCTS    PRODUCTS BY MARKET    DUY    TRANSTECNO CATALOGUES    THE MODULAR GEARMOTOR    Poner f TECNO    SOLAR TRACKER SYSTEMS THE GEARMOTORS  FOR FEEDING SYSTEMS    DOOR FS TECNO FRE PR TECNO    THE GEARMOTORS THE GEARMOTORS  FOR AUTOMAITC DOORS FOR PELLET BONERS       THE GEARMOTORS  FOR INDUSTRIAL CLEANING       Per informazioni sui nostri prodotti  contattare i nostri uffici commerciali    For more info on our products   please contact our Sales Dept     MOTORI ELETTRICI TC  My Y 2                Pag   Page  Indice Index  Caratteristiche tecniche Technical characteristics 2  Designazione Designation 2  Diagramma famiglia TS MY TS MY series system 3  Simbologia Symbols 3  Dati tecnici Technical data 4  Informazioni generali General informations 10  Caratteristiche generali General characteristics 10  Dati cuscinetto  paraoli  pressacavi Ball bearing  oil seal  cable glands data 10  Connessioni e collegamenti Connection diagram 11  Forme costruttive e posizione Mounting type and position 12  Part 2 Grado di protezione IP IP enclosure protection indexes 13  en Classe di isolamento termico Thermal insulation class 13  General Tipi di servizio IEC IEC duty services 14  informations Grafico servizi pi   comuni Most common services diagrams 14  Serie TS   Funzionamento in ambiente 60 Hz TS Series   60 Hz line power supply 15  Linee guida di montaggio Mounting guidelines 16  Motori ad efficienza superiore High efficiency motors 
18. TO mounted  use   full to give out an alarm or  by the means of suitable connection  to  cut the current from the line    Must be applied all protections due to the application  for instance   over speed due to load drag  undervoltage  etc      Follow the rules for selection of suitable cable section  depending  on lenght of cables and current    Strongly forbidden to reset automatically a protection after trip   ping  hazardous conditions may caused  Only skill personnel allo   wed to reset manually the protection     Do not touch the motor surface  it could be hot  After motor is  stopped  wait for a while of time to allow the external case to cool  down    Keep clean the surface of the motor and good life the fan  Do not  remove the fan cover     Before doing any work on the motor or in surrounding areas  make  sure it is cut off from power source  Wait for masses stop     Maintenance   Before doing any work on the motor or in surrounding areas  make  sure it is cut off from power source  Wait for masses completely  stop  Take care that cannot be moved by other connected machi   nes    Check mechanical worn of shaft  power leads status  fan status   and whatever needed by the kind of job     MOTORI ELETTRICI TS  MY    High efficiency motors       Motori ad efficienza superiore     gt     7  E     I    RG  ING    um  DZ   lt      lt m    La convenzione di Kyoto ha posto l attenzione di tutti sulla dram   matica situazione ecologica del riscaldamento globale causato  dall em
19. a 6 poli   una tensione nominale massima di 1000V  una potenza nominale  compresa tra 0 75 kW e 375 kW  caratteristiche basate su un  funzionamento in continuo      a partire dal 16 giugno 2011 i motori  devono avere come minimo un livello di efficienza IE2     Negli anni successivi si porranno in obbligo livelli ancora superiori  di efficienza    Disponibili anche motori IE3 e MEPS2  Australia     Prego contattare Transtecno per offerte e informazioni tecniche     The Kyoto Convention has drawn the world s attention to the dra   matic ecological problem of Global Warming  caused by emissions  of greenhouse gases    As a result of the current economic situation and the increasing  difficulty to find energy resources  the European Commission has  adopted concrete measures in order to save energy    Due to the increasing use of AC motors in industry  stricter laws  are being brought in to the EU  They are aimed specifically to in   crease the efficiency of motors classified as IE1  IE2  IE3 etc   Efficiency is expressed as a percentage of the effectiveness of a  motor to convert electrical energy into mechanical work  therefore  increasing the efficiency means getting the same outcome with  less power    With benefits for everyone  including nature    From June 2011 motors with low efficiency  IE1  will be banned   forcing motors to be redesigned with more suitable materials  Be   fore the new legislation comes into act  Transtecno can offer on  request motors classified as IE2
20. ca     Part 2   Informazioni generali   General informations    Warnings for right and safe use of AC motors  Recommended installation  use and maintenante to skill perso   nel     The below suggestions do not cancel common sense and  caution needing  and do not replace laws and standard rules  in specific field applications    Receiving   Before installation  check that the fan cover  frame  shaft are not  damaged due to shipment  Check data of nameplate  do not use  if they are not suitable for the application  voltage  frequency  tor   que  IP protection degree  speed  temperature service     If needing  store the electric motor in a dry and clean room     Running   Fit securely the electric motor in the working seat    The exposed mechanical parts and transmission parts must be  protected from contact with people  animals and properties   Recommended to connect the ground clamp to the outside pro   tection system or grounding circuit    Never start the motor with free key  it could be thrown out by the  centrifugal force and make damage    If a reversed direction can cause problem to people  animals or  property  must be mounted near the motor a clear visible arrow  showing the correct and prescribed direction     Suggested suitable overcurrent protection  for instance  by the  means of thermal relais  that automatically drive a knife switch   Fuses and current protection devices must be set under the stall  current value     MY series motors are available with standard P
21. e da raggiungere temperature elevate  Sotto alcu   ni esempi dell utilizzo    La pastiglia termica in dotazione standard    un contatto normal   mente chiuso  si apre al superamento della temperatura di soglia   Attenzione  si tratta solo di esempi  affidarsi a personale esperto     Linea   Line       Linea   Line    Teleruttore  Contactor    Part 2          gt     ta        MY series is provided with standard bimetallic thermal protector   PTO  monitoring overtemperature  135  C   5  C   Suggested in  high temperature motor applications  Below some examples     Standard built in thermal protector is a normally closed contact  It  opens over temperature threshold   Take care they are only examples  PLS  refer to skill personnel       230V    Allarme luminoso o acustico normalmente chiuso  Lamp or acustic allarm normally closed                     PLC o simile  PLC or similar      230V    Informazioni generali   General informations          Forme costruttive e posizione Mounting type and position                                                                                                          IM 1001  B3  IM 1051  B6                                                                                                                                                                                               ALLE                                                                                                             IM 1011  V5  IM 1031  V6        9 9          e IM 1061 
22. eavy and light industrial applications suitable and commercial  ones     Designation       TS 63 2 B5 230 400 50 Hz  Tipo Grandezza Indicativo potenza Forma costruttiva Tensione Frequenza  Type Size Power coefficient Poles Version Voltage Frequency  TS vedi tabelle 1 2 3 S 2 4 6 8 B5 230 400 50Hz  trifase cdd L L1 L2 B14 60Hz  threephase M1 M2 B3  MY 63 2 B5 230 50 Hz  Tipo Grandezza Indicativo potenza Poli Forma costruttiva Tensione Frequenza  Type Size Power coefficient Poles Version Voltage Frequency  MY vedi tabelle 2 B5 230 50Hz  monofase see tables B14  singlephase             eee A  THE MODULAR GEARMOTOR  www transtecno com             3   ASINCHR  MOTOR       pF          Serv  S 1          kW A 220   240 380   415 Y       rpm       kW A 264   288 456   498 Y          rpm          IP 55 Is cl  F       MOTORI ELETTRICI TS  MY SI    5       Diagramma famiglia TS MY    TS MY series system           TS       MY    Motori monofase  Singlephase motors  230   50Hz    Motori trifase  Threephase motors  230 400V   50Hz         2 poli poles  0 09   18 5 Kw    4 poli poles  0 06   18 5 Kw    6 poli poles  0 09   11 Kw        8 poli poles  0 09   7 5 Kw    4 poli poles  0 09   0 75 Kw       Grafico generale coppia corrente velocit                           Ore              L          Ore    B          E    Torque current speed general diagram                                                                Coppia 4 Corrente  Torque   Current   Mn   A                 Simbologia e for
23. ersion fixture for a long time           Classe di isolamento termico    Insulation class       La classe termica indica il grado di resistenza alla temperatura  interna  nel punto pi   caldo  avvolgimenti   Maggiore il carico e  migliore deve essere il livello di protezione    Attiene alle resine e in generale a tutti i materiali interni di isola           Thermal insulation class is the level of thermal protection  measu   red inside the motor  in the hottest point  windings   Bigger load  and better the level of thermal insulation required    Related to resin and all the internal insulation materials                                                                       mento   C    180   7   SN i Margine di sicurezza  7 _ 15     SN   Safety margin  Standard 155  q           j  140       AME  _ i fy  120   PELA    Massima 5   Surriscaldamento  ammissibile  Classe temperatura 100   7 125   Admissible  Class interna Beli overheating  Max  windings 80 75   80    temp  60      E 120  C    B 130  C 40 Temperatura ambiente  40   40   40   convenzionale 40   C  Ce l         Conventional ambient  H 180  C temperature 40   C  E B F H    Part 2   Informazioni generali   General informations       E ML       Tipi di servizio IEC    IEC duty services       Il servizio di un motore indica il tipo di utilizzo e la gravosit   del  ciclo di lavoro  Lo stesso motore pu   funzionare in tutti i servizi   purch   si moduli la potenza nominale al fine di consentire il cor   retto equilibrio ter
24. ico intermittente con avviamento  Sequenza  di cicli di funzionamento identici di avviamento  marcia e riposo a  carico costante  senza raggiungimento dell equilibrio termico  La  corrente di spunto ha effetti sul riscaldamento del motore     Intermittent periodic duty with starting  Sequential identical  start  run and rest cycles with constant load  Temperature equili   brium is not reached  but starting current affects temperature rise        S5    Servizio periodico intermittente con frenatura elettrica   Sequenza di cicli di funzionamento identici di avviamento  marcia a  carico costante  frenatura elettrica e riposo  senza raggiungimento  dell equilibrio termico     Intermittent periodic duty with electric braking  Sequential   identical cycles of starting  running at constant load  electric bra   king and rest  Temperature equilibrium is not reached        S6    Servizio periodico ininterrotto con carico intermittente   Sequenza di cicli di lavoro identici con carico costante e senza  carico  Non ci sono periodi di riposo     Continuous operation with intermittent load  Sequential  iden   tical cycles of running with constant load and running with no load   No rest periods        S7    Servizio periodico ininterrotto con frenatura elettrica   Sequenza di cicli di funzionamento identici di avviamento  marcia a  carico costante e frenatura elettrica  senza periodi di riposo     Continuous operation with electric braking  Sequential  identi   cal cycles of starting  runni
25. issione di grandi quantit   di gas serra  Unitamente alla  congiuntura economica e alla maggior difficolt   di reperire fonti  di approvvigionamento energetico  la commissione europea ha  imposto l adozione di misure concrete per il risparmio energetico   Dato il considerevole uso di motori elettrici CA nell industria mon   diale  norme pi   rigide stanno per entrare in vigore nella CE  In  particolare miranti ad aumentare l efficienza dei motori  classificati  in classi crescenti da IE1  IE2 IE3 e cosi via  L efficienza    la mi   sura espressa in percentuale dell efficacia di un motore di conver   tire energia elettrica in meccanica  quindi aumentare l efficienza  significa ottenere lo stesso lavoro a minor consumo energetico   Con benefici per tutti  natura compresa    Dal giugno del 2011 saranno banditi i motori con la classe pi    bassa di efficienza  gli IE1  spingendo a ridisegnare gli stessi e a  Scegliere materiali piu adatti  In anticipo rispetto alla legislatura   Transtecno offre su richiesta i motori a classe IE2     Pi   in dettaglio il testo cita    il REGOLAMENTO  CE  N  640 2009 DELLA COMMISSIONE  EUROPEA del 22 luglio 2009 recante modalit   di applicazione  della direttiva 2005 32 CE del Parlamento europeo e del Consiglio  in merito alle specifiche per la progettazione ecocompatibile dei  motori elettrici     si intendono applicati a    un motore elettrico a induzione a gabbia  mono velocit   e trifase   con una frequenza di 50 Hz o 50 60 Hz che abbia  da 2 
26. mico     Lo stesso motore    dichiarato per potenze diverse se    diverso il    servizio     Motor service describes kind of work and cycle of running  The  same motor works under all services but adjusting the rated po   wer in order to have the right temperature balance  About the  same motor  different rated powers against different services       S1    Servizio continuo  Funzionamento a carico costante per una du   rata sufficiente al raggiungimento dell   equilibrio termico     Continuous duty  The motor works at a constant load for enough  time to reach temperature equilibrium       S2    Servizio di durata limitata  Funzionamento a carico costante  per una durata inferiore a quella necessaria al raggiungimento  dell equilibrio termico  seguito da un periodo di riposo tale da ripor   tare il motore alla temperatura ambiente     Short time duty  The motor works at a constant load  but not long  enough to reach temperature equilibrium  and the rest periods are  long enough for the motor to reach ambient temperature        S3    Servizio periodico intermittente  Sequenze di cicli identici  di marcia e di riposo a carico costante  senza raggiungimento  dell equilibrio termico  La corrente di spunto ha effetti trascurabili  sul surriscaldamento del motore     Intermittent periodic duty  Sequential  identical run and rest  cycles with constant load  Temperature equilibrium is never rea   ched  Starting current has little effect on temperature rise        S4    Servizio period
27. mule    n Velocit    Speed   rpm     Il grafico evidenzia la caratteristica coppia corrente     giri per un  generico motore asincrono  Si noti che talvolta Msel e MS coin   cidono    Torque Current vs speed diagram of an asynchronous motor   Note  sometimes Msel and Ms are the same     Symbols and formulas          P   kW  Potenza nominale Rated power   In  A  Corrente nominale  a 400V  Rated current  at 400V    Mn  Nm  Coppia nominale Rated torque   On  rpm  Velocita nominale Rated speed   LR  dB  Livello di rumorosit   Noise Level   Ms   Mn Rapporto coppia spunto   coppia nominale Ratio start torque   rated torque  Mx  Mn Rapporto coppia massima   coppia nominale Ratio max torque   rated torque  Mia   Mn Rapporto coppia di sella  minima    coppia nominale Ratio saddle torque   rated torque  ls   ln Rapporto corrente di spunto   corrente nominale Ratio start current   rated current  coso Fattore di potenza al carico nominale Power factor at rated torque load  n Rendimento al carico nominale Efficiency at rated torque load  rd  HP  Potenza  kW  x 1 34 circa Power  kW  x 1 34  about        Potenza resa P        P  output power  kW  Potenza assorbita x n Absorbed power x n  n  VXIXPE PF  monofase  Nm  singlephase   Pot  assorbita  Absorbed power  kw  VxIxN3xPF  trifase  VxIxN3xPE      threephase   1000 1000       In  230 V     In  400 V  x 13    In  400 V  x N3                                                                                                                      
28. ne termica   utile per fornire allarme o  tramite opportuno collegamento  inter   rompere l erogazione di corrente    Si dovranno inserire tutte le protezioni richieste dall applicazione   ad esempio  sovra velocit   dovuta a trascinamento del carico   bassa tensione  ecc     Dimensionare la sezione dei cavi in funzione dello loro lunghezza  e della corrente secondo le normative vigenti    Non tentare il riavvio automatico del motore dopo interruzione di  una protezione  possibili condizioni di pericolo  Affidarsi a perso   nale esperto     Il motore si scalda durante il funzionamento  non toccare e atten   dere il tempo necessario al raffreddamento dopo averlo spento   Mantenere pulita la superficie alettata del motore per favorire lo  scambio termico e in efficienza la ventola  Non rimuovere il copri  ventola     Prima di operare alcun intervento sul motore  togliere alimentazio   ne  possibilmente sezionare fisicamente dalla rete elettrica  atten   dere l arresto delle parti in movimento e verificare che non possa   no essere trascinate da altre parti della macchina collegate     Manutenzione   Prima di operare alcun intervento sul motore  togliere alimentazio   ne  possibilmente sezionare fisicamente la rete di alimentazione   attendere l arresto delle parti in movimento e verificare che non  possano essere trascinate da altre parti della macchina collegate   Controllare usura meccanica albero  stato dei cavi di alimentazio   ne  stato ventola e quant altro l uso suggeris
29. ng at constant load and electric braking   No rest periods        S8    Servizio periodico ininterrotto con variazioni di carico e di ve   locit    Sequenza di cicli identici di avviamento  marcia a carico  costante e velocit   definita  seguiti da marcia a carico costante  differente e velocit   differente dalla precedente  Non ci sono pe   riodi di riposo     Continuous operation with periodic changes in load and spe   ed  Sequential  identical  duty cycles of start  run at constant load  and given speed  then run at other constant loads and speeds  No  rest periods        S9          Servizio con variazioni di carico e velocit   non periodiche       Load and speed non periodic variations          Grafico servizi pi   comuni    Most common services diagrams       N   funzionamento   run                            Durata di un ciclo                                        R   riposo   rest Period  A A N R   Carico           Carico  Load Load   S1    2 S3 d    Perdite Perdite  elettriche elettriche  Power loss   TTT  77 Power loss   z        Tmax Tmax   p  Temperatura Temperatura  Temperature Temperature  0 Tempo   Time 0 Tempo   Time    NOTA  Lo stesso motore pu   essere usato per cicli e servizi di        NOTE  The same motor can run under all duty services  limitation    is due to internal temperature that must not override Tmax stated  by motor thermal class     versi  con l unica limitazione che la temperatura interna non su   peri mai la Tmax stabilita dalla classe di is
30. olamento termico del  motore     Part 2   Informazioni generali   General informations    MOTORI ELETTRICI FG _ MY Y       Serie TS   Funzionamento in ambiente 60 Hz    Series TS   60 Hz line power supply       In via teorica il motore 400 V 50 Hz pu   essere alimentato a 60   Hz con le seguenti conseguenze    e La velocit   aumenta del 20   perch   dipendente direttamente  dalla frequenza    e La coppia modifica in funzione della tensione  infatti il rapporto  tensione frequenza    proporzionale al flusso magnetico am   messo     A 400 V la coppia cala di circa il 2096 mentre la potenza rimane  invariata    A 480 V la coppia rimane invariata e la potenza aumenta del  20  circa    Valori intermedi di tensione producono effetti intermedi     400 V standard    Theorically a 400 V 50 Hz motor can run under 60 Hz line but fol    lowing modifications    e Speed encreases 20  because following directly the fre   quency    e Torque varies depending on voltage  because ratio Volt herz is  proportional to available magnetic flux      400 Vac torque decreases about 20  but power still remains  the same   480 Vac torque is still the same and power encreases 20      Mean voltage gives mean results     Velocit     speed     20   Coppia   torque    20   Potenza   power   invariata   the same       Velocit     speed   invariata   the same  480 V Coppia   torque   potenza   power    20    Attenzione  perdite e surriscaldamento  Take care loss and overheating          Velocit     speed     20
31. opriventola   Fan cover       Viti copriventola   Self threading screws for fan cover fixing       17   Porta terminali completo   Terminal board complete       18   Guarnizione   Terminal seal       19   Viti scatola morsettiera   Screws for terminal box fixing       20   Pressacavo   Cable gland       21   Scatola morsettiera   Terminal box  base        22   Coperchio scatola morsettiera   Terminal box  cover        24   Viti scudi   Mounting studs screws   25   Flangia B5   Flange B5   26   Flangia B14   Flange B14   27   Viti coperchio   Screws for terminal box fixing                         Part 2   Informazioni generali   General informations    MOTORI ELETTRICI TS  M Y Y    Lista dei componenti MY MY spare parts list                     LIS  NOA    MSS               Corpo motore B5 B14   Frame B5 B14       Statore   Wound stator       Albero   motore   Rotor with shaft          Chiavetta   Key  Scudo posteriore   Back shield          2  3  4  6   Cuscinetti   Bearings  7  8  9    Etichetta   Nameplate          10   Anello di tenuta   Spring washer  11   Viti e dadi   Rods and nuts  12   Ventola   Cooling fan             13   Seeger ventola   Fan circlip       14   Paraolio   Rubber seal ring       15   Copriventola   Fan cover       16   Viti copriventola   Self threading screws for fan cover fixing       17   Porta terminali completo   Terminal board complete       18   Guarnizione   Terminal seal       19   Viti scatola morsettiera   Screws for terminal box fixing   
32. otor body   15  figure indicating level of protection against the penetration of    solid    bodies     2n figure  indicating degree to which the motor is waterproof                                                                       IP Definizione   Description IP Definizione   Description  0 Non protetto   No protection 0 Non protetto   No protection     50 mm Protetto contro la caduta verticale di gocce  4 e Protetto da corpi solidi superiori a    50 mm  1 d acqua   i O   Protected against solid matters  over    50 mm  Protected against drops of water falling  Sale    vertically  i ls nm Protetto da corpi solidi superiori a    12 mm  si RAM ener anid Ml  gt  gocce  2 Hi O Protected against Sold matters  Over    12 2 Protected against drops of water falling up    1 mm  o  LM to 15     2 5 mm  3 ET   Protetto da corpi solidi superiori a Y 2 5 mm  3 Protetto contro la pioggia   i O i Protected against solid matters  over    2 5 mm  Rain proof fixture  y I     1mm  4  m i Protetto da corpi solidi superiori a  1 mm  4 Protetto contro gli spruzzi   O H Protected against solid matters  over  1 mm  Splash proof fixture  SALZ  5 Protetto contro la polvere 5 Oh Protetto contro getti d acqua  Dust proof ATN Water jet proof  Ys  6 Totalmente protetto contro la polvere 6 ES  gt  Protetto dalle ondate  Fully dust proof eh Wave proof  7 NA 7 Protetto contro immersione  UC O Watertight immersion fixture      Protetto contro immersione sommersione  8 N A  8 Q X prolungata  Watertight imm
33. tiera  terminal box    80 90                               AF1          Dimensioni motori monofase serie MY B5       MY Series single phase motors dimensions                      AC                                                       Dimensioni motori monofase serie MY B1 4    MY Series single phase motors dimensions    90    I RK for  4 holes                                                                                  E ML       Informazioni generali General informations    Caratteristiche generali    General characteristics       e Ventilazione  ventola a pale radiali in materiale plastico     e Copriventola  in lamiera stampata consente ottima canalizza   zione del flusso e protezione alla ventola   e Rotore  del tipo a gabbia di scoiattolo  equilibrato dinamica     mente     Dati cuscinetto  paraoli  pressacavi    Carcassa  lega di alluminio di elevata resistenza   Avvolgimento  isolamento termico di classe F    Protezione  IP55  Temperatura ambiente   20   C    40   C    Cooling  by the means of fan with plastic radial blades    Fan cover  sheet metal  for high performance air flux driving   and fan protection    Rotor  squirrel cage type  Dinamically balanced     Body  aluminium alloy with high mechanical strength   Windings  class F thermal insulation    IP55 protection degree   Ambient temperature   20   C    40   C    Ball bearing  oil seal  cable glands data                                                                         TS  56 6201 2RZ 6201 2RZ 12x22x
    