Home
        Manuale tecnico
         Contents
1.     Ta x                hr om      dh  cl    as Y A           Legenda schema elettrico a pagina 19    Wiring diagram explanation on page 19     Schaltplan Erkl  rung auf Seite 19    Explication de le diagramme   lectrique a la page 19     18    LEGENDA SCHEMI ELETTRICI    SCHALTPL  NE ERKL  RUNG    Al  A2  A3  CE  CMC  CMV1  CMV2        F1  FLC  FMP  KF  KMC  KMP  MC  MP  MV1  MV2  QMC  Qs  RC  SPH  SPL  SPW  SR  ST1  ST2  TR  YVI    19    DENOMINAZIONE    Controllo elettronico    DESIGNATION    Electronic control    ELECTRICAL DIAGRAMS EPLANATION    BEZEICHNUNG    Elektronischer controller    EXPLICATION DE LE DIAGRAMMES   LECTRIQUES    DESIGNATION    Commande   letronique       Terminale remoto    Remote terminal    Fernbedienungstafel    Tableau de controle  a distance       Interfaccia seriale    Serial interface    Serielle schnittstelle    Interface serie       Consenso esterno    External interlock    Externe zustimung    Consentement ext        Condensatore compressore    Compressor condenser    Kondensator Verdichter    Condenseur compresseur       Condensatore ventilatore    Fan condenser    Kondensator gebl  se    Condenseur ventilateur       Condensatore ventilatore    Fan condenser    Kondensator gebl  se    Condenseur ventilateur          Commutatore Summer Winter Umschalter Sage  estate inverno  WP  Changeover  WP  Sommer Winter  WP  Comm  Et   Hiver  WP   Fusibile Fuse Sicherung Fusible       Filtro antidisturbo    Filter for harmonic current    Filter f  r ha
2.    FOULING FACTOR CORRECTIONS    COEFFICIENTS CORRECTEURS POUR  FACTEURS D   ENCRASSEMENTS    Evaporator fouling factors  m   C W     Facteure d   encrassemente evaporateur  m   C W              f1 fp1  0 Piastre pulite   Clean plate exchanger 1 1 O Sauberer W  rmetauscher   Echangeur propre  0 44 x 10  0 98 0 99 0 44 x 10   0 88 x 10    0 96 0 99 0 88 x 10   1 76x 10  0 93 0 98 1 76 x 10       f1  fattori di correzione per la potenza resa            fattori di correzione per la potenza assorbita dal compressore   Le prestazioni delle unit   indicate nelle tabelle vengono fornite per le  condizioni di scambiatore pulito  fattore di sporcamento   0   Per valori  differenti del fattore d   incrostazione  le prestazioni fornite dovranno  essere corrette con i fattori indicati     f1  Korrekturfaktoren f  r Kalteleistung bzw  Verfl  ssigerleistung           Korrekturfaktoren f  r Leistungsaufnahme von dem Verdichter   Die in der Tabelle angef  hrten Ger  teleistungen sind f  r die Bedingung  eines sauberen W  rmetauschers angegeben  Verschmutzungfaktor   0    Bei unterschiedlichen Werten des Verschmutzungsfaktors m  ssen die  Leistungen mit den angegebenen Faktoren korrigiert werden     fl  capacity correction factors    fp1  compressor power input correction factor    Unit performances reported in the tables are given for the condition of  clean exchanger  fouling factor   0   For different fouling factors values   unit performances should be corrected with the correction factor
3.    kg  12      19 244 1     1  M  22 246 1     1  M  25 248 1     1 M  Per le unita a pompa di calore maggiorare il peso del 10   For units in heat pump version increase the weight by 10    F  r die W  rmepumpeausf  hrungeinheiten mu   das Gewicht Pour les groupes a pompes a chaleur majorer le poids de 10      um 10  erh  ht werden     17    SCHEMA ELETTRICO   MODELLI 19   25 ELECTRICAL DIAGRAM   MODELS 19   25                                                                                                                                                                                                                                                                                                                                                                                                                                                       VERSIONI  RPE X   HPE X VERSION  HRPE X   HPE X  SCHALTPLAN   MODELLE 19   25 DIAGRAMME   LECTRIQUE   MODEL 19   25  BAUVARIANTE  RPOE X   HPE X VERSION  RPE X   HPE X    E do   lt          A ee en el     get EE  LO   x     w D                 X2 00                    I  li  Bu       Abs      2 24    2 00 ni x2 15    E GER     i       ess EE     2    5      X2 00 T      2 o  a   lt   gt  lt   L  uo   2 34                     X2 00 X2 12  gt     um  s X2 91  X2 00 a SCH          571  N af      2  NA db 8  SR A        ms 2  X2 46  PP x     X2 44 bal  il          ote 3      3     x2 45                 X2 44 g    x2 N    2  ES                 
4.   PRESSOSTATO BASSA AUT   accessorio     LOW PRESS  SWITCH A R   accessory     NIEDERDRUCKSCHALT  AUT   Zubeh  r     PRESS  BASSE PRESS  AUT   accessoire                    SERBATOIO STORAGE TANK SPEICHERBEH  LTER BALLON TAMPON   SONDA DI LAVORO WORKING PROBE WASSERTEMP   FUHLER SONDE DU TRAVAIL  SONDA ANTIGELO ANTIFREEZE PROBE FROSTSCHUTZF  HLER BENUTZERSEITE SONDE ANTIGEL  TRASDUTTORE DI PRESSIONE PRESSURE TRANSDUCER DRUCKGEBER TRANSDUCTEUR DE PRESS  VASO DI ESPANSIONE EXPANSION VESSEL AUSDEHNUNGSGEF  B VASE D EXPANSION       VALVOLA DI SICUREZZA 300 kPa    SAFETY WATER VALVE 300 kPa    SICHERHEITSVENTIL 300 kPa    VANNE DE SECURITEE EAU 300 kPa       VALVOLA D ESPANSIONE    EXPENSION VALVE    EXPANSIONSVENTIL    SOUPAPE D EXPANSION    SCHEMA CIRCUITO FRIGORIFERO E IDRAULICO UNITA     A POMPA DI CALORE    HYDRAULISCHER ANSCHLUB UND KALTESCHEMA DER                            WARMEPUMPE VERSION UNIT      POMPE    CHALEUR  TRGV      22      x        KT     CAR  CEC  CV  EW  FD  LR  MC  MN  MP  MV  PD  RCV  SC  SPH  SPL  ST  ST1  ST2  TRGV  VE  VSI  VSI1                                                   REFRIGERANT AND HYDRAULIC CIRCUIT DIAGRAM  UNIT IN HEAT PUMP VERSION    SCHEMAT DU CIRCUIT HYDRAULIQUE ET FRIGORIFIQUE                                                                                  4  DENOMINAZIONE DESIGNATION BEZEICHNUNG DESIGNATION  CARICO LOAD LAST CHARGE  BATTERIA CONDENSANTE EVAPORANTE CONDENSING EVAPORATING COIL VERFL  SSIGER VERDAMPFERREGISTER BATTERIE 
5.   rieur  La gamme est compos  e de    mode   les d   une puissance de 15 iusqu   a 20 kW     DIFFERENTES VERSIONS     RPE X   froid seul avec ballon tampon et pompe   HPEX   pompe    chaleur r  versible avec ballon tampon  et pompe   CARACTERISTIQUES     Structure  A cadre portant  est r  alis  e en peraluman et en t  le  galvanis  e et il est dou    a la base  de supports antivibratiles en  caoutchouc  Vis en acier inox    Compresseur  Scroll triphase avec protection thermique interne  par klixon  si n  cessaire r  chauffeur de carter et mont  s sur  supports antivibrants en caoutchouc    Ventilateurs  De type axial directement accoupl  es a un moteur    l  ctrique monophase  avec protection th  rmique interne par  klixon  La classe de protection du moteur est en IP44  at les  ventilateurs comprennent une grille de protection et de s  curit       Condenseur  Batterie en tube de cuivre et ailettes d   aluminium   complete de bac a condensats dans la version pompe a chaleur     Evaporateur  A plaques soudo bras  es      acier inox AISI 316 inse   r  e                   de l   unit      Tableau   lectrique  Inclus  sectionneur g  n  ral avec dispositif de  blo cage de porte  fusibles  filtre pour courants harmoniques   t  l  rupteur pompe    Microprocesseur pour le contr  le des fonctions suivantes  r  gulation  de la temp  rature de l eau  protection antigivre  temporisation des com   presseurs  r  armement alarmes  boucles s  ches pour signalisation des  alarmes a distance et
6.   rmepumpe Einheiten 12  Verwendung von  Wasser Ethylenglikol Mischungen 14  Schalldruckpegel 16  Au  enma  e  Gewichte  Raumbedarf  und hydraulische Anschl  sse 17  Schaltpl  ne 18  Schaltpl  ne Erkl  rung 19  Hinweise zur Installation 20    INDEX Pag   General description 4  Versions 4  Technical features 4  Separately supplied accessories 4  Technical data 6  Cooling capacity 7  Heating capacity 8  Circulation pump available static pressure 9   Fouling factor corrections 10  Operating range 10  Refrigerant   hydraulic chiller circuit diagram  circuit diagram   only cooling units 11   heat pump units 12  Operation with ethylene glycol mixtures 13  Sound pressure level 15  Dimensions  weights  clerances and  hydraulic connections 17  Electrical diagrams 18  Explanation of electrical diagrams 19  Installation recommendations 20   INDEX Pag   Description generale 5  Differentes versions 5  Caract  ristiques 5  Accessoires fournis separement 5  Caract  ristiques techniques g  n  rales 6  Puissance frigorifique 7  Puissance calorifique 8  Pression utile de la pompe de circulation 9  Coefficients correcteurs pour  facteurs d   encrassements 10  Limites de fonctionnement 10  Schemat du circuit hydraulique et frigorifique   groupe de production d   eau glac  e 11   unit   a pompe a chaleur 12  Utilisation de la solution eau glycol ethylenique 14  Niveaux de pression sonore 16  Encombrements  poids  espaces pour  entretien et raccordements hydrauliques 17  Diagrammes electriques 18 
7.  13 15 17  Corrente max spunto A 61 78 106  Livello sonoro  3  dB A  51 0   Peso in esercizio RPE kg 194 196 198  Peso di trasporto RPE kg 244 246 248  Peso in esercizio HPE kg 213 216 218  Peso di trasporto HPE kg 268 271 273                    1  Acqua refrigerata da 12 a 7   C  temperatura aria esterna 35   C    2  Acqua riscaldata da 40 a 45   C  temperatura aria esterna 7   C b s  6   C b u      3  Livello medio di pressione sonora rilevato in campo libero ad 1 m dall   unita  Q 2  secondo ISO 3744    R410A                                                 RESE IN RAFFREDDAMENTO COOLING CAPACITY  KALTELEISTUNGEN PUISSANCE FRIGORIFIQUE  TEMPERATURA ARIA ESTERNA   C   AMBIENT AIR TEMPERATURE   C  M O D UMGEBUNGSTEMPERATUR   C   TEMPERATURE AIR EXTERIEUR   C  S 25 28 32 35 40 45  To  C       kWe kWf kWe kWf kWe        kWe kWf kWe        kWe  5 16 2 4 2 15 6 4 5 14 9 4 5 14 3 4 9 13 3 5 5 12 2 6 1  6 16 7 4 3 16 2 4 5 15 4 4 6 14 8 4 9 13 7 5 5 12 6 6 2  19 7 17 3 4 3 16 7 4 6 15 9 4 6 15 3 5 0 14 2 5 6 13 0 6 2  8 17 8 4 4 17 2 4 6 16 4 4 7 15 8 5 1 14 7 5 6 13 6 6 2  9 18 1 4 5 17 8 4 7 17 0 4 7 16 3 5 1 15 1 5 7 14 1 6 3  10 20 5 4 5 18 4 4 7 17 6 4 8 16 8 5 2 15 6 5 8 14 6 6 3  5 19 7 5 0 19 0 5 3 18 1 5 5 17 4 5 9 16 2 6 6 14 9 7 4  6 20 3 5 1 19 7 5 5 18 7 5 5 18 0 5 9 16 7 6 6 15 3 7 4  22 7 21 0 5 2 20 3 5 5 19 3 5 6 18 6 6 0 17 2 6 7 15 8 7 5  8 21 4 5 2 20 9 5 6 20 0 5 7 19 2 6 1 17 9 6 7 16 5 7 5  9 22 0 5 3 21 7 5 7 20 6 5 7 19 9 6 1 18 4 6 8 17 1 7 6  10 24 9 5 4 
8.  Explication de le diagrammes   lectriques 19  Conseils pratiques pour l   installation 20          DESCRIZIONE GENERALE    Refrigeratori d   acqua condensati ad aria con ventilatori assiali per  installazione esterna  La gamma comprende 10 modelli che copro   no potenzialita frigorifere da 15 a 20 kW     VERSIONI   RPE X   solo raffreddamento con serbatoio e pompa  HPE X   pompa di calore reversibile con serbatoio e    pompa    CARATTERISTICHE COSTRUTTIVE    Struttura  A telaio portante     realizzata in peraluman e lamiera zin   cata ed    dotata  alla base  di supporti antivibranti in gomma  Viteria  in acciaio inox    Compressori  Scroll ermetico trifase completi di protezione  interna  klixon  e resistenza carter  ove il costruttore lo preveda   montati su supporti antivibranti in gomma    Ventilatori  Di tipo assiale a basso numero di giri e profilo alare  speciale  sono direttamente accoppiati a motori a rotore esterno  con grado di protezione IP44  Una rete antinfortunistica    posta  sull usci ta dell aria     Condensatore  Costituito da una batteria alettata con tubi di rame  ed alette in alluminio  completo di vaschetta raccogli condensa per  la versione a pompa di calore    Evaporatore  Del tipo a piastre saldobrasate in acciaio inox AISI  316  inserito all interno del serbatoio    Quadro elettrico  Include  sezionatore generale con dispositivo  bloccoporta  fusibili  filtro antidisturbo  teleruttore compressore e  teleruttore pompa    Microprocessore per la gesti
9.  agendo sulla valvolina  di sfiato  Questa procedura    particolarmente importante in quanto anche piccole  bolle d   aria possono causare il congelamento dell   evaporatore      Scaricare l impianto idrico durante le soste invernali o usare appropriate  miscele anticongelanti      Installare sempre un filtro a rete metallica sull ingresso dell unit   a protezione  dello scambiatore a piastre      Realizzare il circuito idraulico includendo i componenti indicati negli schemi  raccomandati  valvole di sfiato  valvole di intercettazione  valvola di taratura   giunti antivibranti  ecc      Avviamento e manutenzione      Attenersi scrupolosamente a quanto indicato nel manuale di uso e manutenzione   Tali operazioni devono comunque essere effettuate da personale qualificato     HINWEISE ZUR INSTALLATION    Aufstellung      F  r ausreichende Be und Entl  ftung des Ger  tes sorgen      Die Aufstellung des Ger  tes ist so vorzunehmen das es allseitig erreichbar ist      Esistdarauf zu achten  da   es am Aufstellungsort integrierbar ist  das hei  t  Beachtung der Schallentwicklung und die Integration in die vorhandenen  Strukturen     Elektrische Anschl  sse      Beachten Sie die beigef  gten Schaltpl  ne nach welchen der  Elektroanschlu   vorzunehmen ist      Das Ger  tistmindestens 12 Stunden vor der Inbetriebnahme mit Spannung  zu versorgen  um die Kurbelwannenheizung des Verdichters  falls Verfl  gbar   in Betrieb zu setzen  Die Stromversorgung der Kurbelwannenheizung   falls Verf
10.  commutation locale ou a distance du cycle refroi   dissement chauffage dans les pompes a chaleur  Visualisation sur    cran pour  cycle de fonctionnement  refroidissement ou chauffage    compresseur standby on  temp  rature de l eau d entr  e  consigne tem   p  rature et diff  rentiel pr  vus  d  signation des alarmes    Dispositif   lectronique proportionnel pour l att  nuation du niveau  sonore  obtenue au moyen de r  gulation en continu de la vitesse de  rotation des ventilateurs  Cet dispositif permet aussi le fonctionne   ment de l unit   en refroidissement             des temp  ratures de l air  ext  rieur de  20   C     Version RPE X  Circuit frigorifique  Le circuit  r  alis   en tuyau de cuivre  inclut  filtre  deshydrateur  soupape d   expansion et pressostat de haute pression  a r  armement manuel   Circuit hydraulique  Le circuit  r  alis   en tuyau de cuivre  inclut   pressostat diff  rentiel eau  purge d air manuel  r  servoir  calorifug    pompe  soupape de s  ret    3 bar                       robinet  de charge et d  charge installation vase d ex pansion inser  e     l interieur de l   unit      Versions HPE X  Circuit frigorifique  Le circuit  r  alis   en tuyau de cuivre  inclut   filtre d  shydrateur bi directionnel  soupape d   expansion  soupape de  retenue  soupape d   inversion a quatre voies et pressostat de haute  pression a r  armement manuel   Circuit hydraulique  Le circuit  r  alis   en tuyau de cuivre  inclut   pressostat diff  rentiel eau  pur
11.  condizioni nominali   acqua in out 12 7   C  aria esterna 35   C      Resa frigorifera  15 3 kW   Portata acqua    15 3x860 5 3600  0 73 1 5   Prevalenza utile pompa  140 kPa     BERECHNUNG DER EXTERNEN STATISCHEN  PRESSUNG DER UMLAUFPUMPE    BEISPIEL    Man nimmt an  man will die externe statische Pressung der  Pumpe in einen Kaltwassersatz RPE X 19 unter den  Nennbedingungen  Wasserein austritt 12 7   C   Umgebungstemperatur 35   C  berechnen     K  lteleistung  15 3 kW   Wasserdurchflu      15 3x860 5 3600  0 73 l s   Externe statische Pressung der Pumpe  140 kPa      Vs     CIRCULATION PUMP AVAILABLE HEAD  PRESSURE CALCULATION    EXAMPLE    The available pump head pressure can be obtained as  follows  considering a RPE X 19 at the nominal conditions   water in out 12 7   C  ambient temperature 35   C      Cooling capacity  15 3 KW   Water flow    15 3x860 5 3600  0 73 1 5   Pump available static pressure  140 kPa     CALCUL DE LA PRESSION DISPONIBLE DE LA  POMPE DE CIRCULATION    EXEMPLE    On suppose vouloir d  terminer la pression disponible de la  pompe    eau sur unit   RPE X 19 aux conditions nominales  eau  entr  e sortie 12 7   C  air ext  rieur 35   C      Puissance frigorifique  15 3 kW   D  bit d eau    15 3x860 5 3600  0  73  5   Pression utile pompe  140 kPa     COEFFICIENTI CORRETTIVI PER FATTORI DI  SPORCAMENTO    KORREKTURKOEFFIZIENTEN FUR  VERSCHMUTZUNGSFAKTOREN    Fattori di sporcamento evaporatore  m  C W     Verschmutzungsfaktoren Verdampfer  m   C W  
12.  hermetischer  komplett mit innerem  Thermoschutzschalter  klixon  und Olwannen heizung  wenn n  tig   auf Dampfungshalterungen aus Gummi  Gebl  se  Die Axialge  bl  se sind direkt mit einemEinphasenelektromotor  gekoppelt und mit internem Thermoschutzschalter  ausgestattet  Der Motor ist nach Schutzart IP44 hergestellt  und  die Gebl  se sind zwecks Unfallverh  tung mit einem Schutzgitter  auf der Luftausblasseite ausgestattet  Kondensator  Gerippter  Verfl  ssigerregister mit Aluminium Lamellen und Kupferrohren   f  r die W  rmepumpe Version komplett mit Kondensatbeh  lter   Verdampfer  Plattenverdampfer aus rostfreiem Stahl AISI 316 in  dem Speicher eingebaut    Schaltschrank  Einschliesslich Hauptschalter mit T  rverriegelung   sicherungen  Filter f  r harmonische Str  me  Pumpe Kontakt   Mikroprozessor f  r die Steuerung der folgenden Funktionen   Wassertemperaturregelung  Frostschutz  Taktsteuerungen der  Kompressoren  Alarm Reset  Alarmsammelkontakt f  r  Fernmeldung und Umschalter Lokal oder Fernsteuerung vom  K  hl  oder Heizzyklus der W  rmepumpen  Displayanzeige f  r   Betriebszyklus  K  hlen oder Heizen   Kompressor Stand by On   Wassertemperatur am Verdampfereingang  Einstellwert u Differenz   Alarmbeschreibung    Elektronische proportionale Vorrichtung zur Schalld  mpfung  mit einer modulanten L  fter Drehzahlregelung  Diese Vorrichtung  erm  glicht den K  hlbetrieb der Einheit auch bei externer Temperatur  bis  20  C     RPE X bauvariante  K  ltekreislauf  Krei
13. 0  Temp di congelamento    C  0  4 5  9 5  Coefficiente correttivo resa frigorifera 1 0 975 0 95  Coeff corr  potenza assorbita compressore    1 01 0 995  Coefficiente correttivo portata miscela 1 1 01 1 04  Coefficiente correttivo prevalenza utile 1 0 96 0 95    ESEMPIO DI CALCOLO    Si fornisce un esempio di calcolo per interpretare in maniera  corretta i coefficienti riportati in tabella     Sisupponga di dover operare           refrigeratore d   acqua RPE X  19 le cui prestazioni alle condizioni nominali siano le seguenti     Resa frigorifera  15 3 kW  Potenza assorbita compressore  4 7 kW  Portata acqua  0 73 l s   Prevalenza utile  140 kPa    Con l   aggiunta del 20  di glicole tali grandezze assumeranno i  seguenti valori  facendo uso dei coefficienti riportati in tabella     15 3x 0 950   14 5 kW  4 7 x 0 995   4 67 kW  0 73x 1 04  0 75 l s    Resa frigorifera   Potenza assorbita compressore   Portata acqua     Dalla curva delle perdite di carico si ricava la prevalenza utile  corrispondente al nuovo valore della portata  0 75 l s    gt  137 kPa      La prevalenza utile corretta relativa ad una miscela di glicole al  20  sar   dunque     Prevalenza utile  137 x 0 95   130 kPa     13    30 40 50  9     15 5  21 5  32 5   Freezing point     C    0 93 0 91 0 88 Cooling capacity correction factor  0 990 0 985 0 975   Compressor absorbed power         factor  1 08 1 14 1 20 Mixture flow correction factor   0 92 0 84 0 78 Available static presseure correction factor  CALCUL
14. 2 7 5 6 22 3 6 4 21 9 7 1  10 70 24 1 5 6 23 7 6 4 23 4 TA  15 60 26 4 5 6 25 9 6 4 25 6 7 1  0 90 221 6 3 21 6 7 2 21 2 8 0  5 90 24 5 6 3 24 0 7 2 23 7 8 0  25 7 87 25 3 6 3 24 9 7 2 24 4 8 0  10 70 26 9 6 3 26 4 7 2 26 0 8 0  15 60 29 4 6 3 28 9 7 2 28 5 8 0  Ta  Temperatura aria esterna a bulbo secco    C   Ta  Ambient air temperature        bulb    C    RH  Umidit   relativa aria esterna      RH  Ambient air relative humidity       kWt  Potenzialit   termica  kW   kWt  Heating capacity  kW    kWe  Potenza assorbita  kW   kWe  Power input  kW    Ta  Externerlufttemperatur d b     C   Ta  Temp  rature air ext  rieure    bulbe sec    C    RH  Relative Externerluftfeuchtigkeit      RH  Humidit   relative a l air ext  rieure       kWt  Heizleistung  kW   kWt  Puissance termique  kW    kWe  Leistungsaufnahme  kW   kWe  Puissance absorbee  kW      R410A    RESE IN RISCALDAMENTO HEATING CAPACITY  HEIZLEISTUNGEN PUISSANCE CALORIFIQUE    TEMPERATURA ACQUA INGRESSO USCITA CONDENSATORE   C  CONDENSER INLET OUTLET WATER TEMPERATURE   C                                        MOD WASSERTEMPERATUR AM VERFL  SSIGEREIN AUSTRITT   C  H TEMPERATURE DE L   EAU ENTREE SORTIE AU CONDENSEUR   C  30 35 35 40 40 45  Ta    C  RH           nee kWt kWe  0 90 17 0 4 9 16 6 5 6 16 4 6 2  5 90 18 9 4 9 18 5 5 6 18 3 6 2  19 7 87 19 5 4 9 19 2 5 6 18 8 6 2  10 70 20 7 4 9 20 3 5 6 20 1 6 2       60 22 7 4 9 22 2 5 6 22 0 6 2  0 90 19 8 5 6 19 4 6 4 19 1 71  5 90 22 0 5 6 21 6 6 4 21 3 7 1  22 7 87 22 7 
15. 22 3 5 7 21 4 5 8 20 4 6 2 19 0 6 9 17 7 7 6  5 21 7 5 5 21 0 5 9 19 9 6 0 19 2 6 4 17 8 7 3 16 4 8 1  6 22 4 5 6 21 7 6 0 20 6 6 1 19 8 6 5 18 4 7 3 16 9 8 1  25 7 23 2 5 7 22 4 6 1 21 3 6 1 20 5 6 6 19 0 7 4 17 5 8 2  8 23 9 5 8 23 1 6 1 22 0 6 2 21 2 6 7 19 7 7 4 18 2 8 3  9 24 2 5 9 23 9 6 2 22 7 6 3 21 9 6 7 20 3 7 5 18 9 8 3  10 27 4 5 9 24 6 6 2 23 5 6 3 22 5 6 8 21 0 7 6 19 6 8 4        Potenzialit   frigorifera  kW   kWf  Cooling capacity  kW    kWe  Potenza assorbita  kW   kWe  Power input  kW    To  Temperatura acqua in uscita evaporatore  Atingr  usc  5 K   To  Evaporator leaving water temperature  At in  out  5 K          Kalteleistung  kW          Puissance frigorifique  kW    kWe  Leistungsaufnahme  kW   kWe  Puissance absorbee  kW    To  Wassertemperatur am Verdampferaustritt  At Ein Austritt  5 K   To  Temperature sortie eau   vaporateur  At entr  e sortie  5 K    RESE IN RISCALDAMENTO HEATING CAPACITY  HEIZLEISTUNGEN PUISSANCE CALORIFIQUE    TEMPERATURA ACQUA INGRESSO USCITA CONDENSATORE   C  CONDENSER INLET OUTLET WATER TEMPERATURE   C                                        MOD WASSERTEMPERATUR AM VERFLUSSIGEREIN AUSTRITT   C  H TEMPERATURE DE L   EAU ENTREE SORTIE AU CONDENSEUR   C  Ta    C  RH    wt we Km ewe I   0 90 17 0 4 9 16 6 5 6 16 4 6 2     90 18 9 4 9 18 5 5 6 18 3 6 2  19 7 87 19 5 4 9 19 2 5 6 18 8 6 2  10 70 20 7 4 9 20 3 5 6 20 1 6 2  15 60 22 7 4 9 22 2 5 6 22 0 6 2  0 90 19 8 5 6 19 4 6 4 19 1 7 1  5 90 22 0 5 6 21 6 6 4 21 3 7 1  22 7 87 2
16. 5 6 22 3 6 4 21 9 7 1  10 70 24 1 5 6 23 7 6 4 23 4 7 1  15 60 26 4 5 6 25 9 6 4 25 6 71  0 90 22 1 6 3 21 6 7 2 21 2 8 0  5 90 24 5 6 3 24 0 7 2 23 7 8 0  25 7 87 25 3 6 3 24 9 7 2 24 4 8 0  10 70 26 9 6 3 26 4 7 2 26 0 8 0  15 60 29 4 6 3 28 9 7 2 28 5 8 0  Ta  Temperatura aria esterna a bulbo secco    C   Ta  Ambient air temperature dry bulb    C    RH  Umidit   relativa aria esterna      RH  Ambient air relative humidity       kWt  Potenzialit   termica  kW   kWt  Heating capacity  kW    kWe  Potenza assorbita  kW   kWe  Power input  kW    Ta  Externerlufttemperatur d b     C   Ta    Temp  rature air ext  rieure a bulbe sec    C    RH  Relative Externerluftfeuchtigkeit      RH  Humidit   relative a l air ext  rieure       kWt  Heizleistung  kW   kWt  Puissance termique  kW    kWe  Leistungsaufnahme  kW   kWe  Puissance absorbee  kW      PREVALENZA UTILE POMPA DI  CIRCOLAZIONE    EXTERNE STATISCHE PRESSUNG  DER UMLAUFPUMPE    300    CIRCULATION PUMP  AVAILABLE STATIC PRESSURE    PRESSION UTILE DE LA POMPE  DE CIRCULATION       200          Prevalenza utile  Available static pressure       Externe statische Pressung  Pression utile disponible   kPa   100                                gt                                               0 5    1 1 50 2    Portata acqua   Water flow   Wasserdurchflu     Debit d eau    CALCOLO PREVALENZA UTILE POMPA  DI CIRCOLAZIONE    ESEMPIO    Si supponga di voler ricavare la prevalenza utile della pompa  su un gruppo frigorifero RPE X 19 alle
17. ATION EXAMPLE    An example can help to use properly the coefficients reported  in the table     Suppose thata waterchillertheRPE X 19 presents the following  performances at the nominal working conditions     Cooling capacity  15 3 kW  Compressor absorbed power  4 7 kW  Water flow  0 73 l s   Available static pressure  140 kPa    With 20  glycol mixture these parameters will change to the  following values  according to the correction factors     15 3x 0 950   14 5 kW  4 7 x 0 995   4 67 kW  0 73x1 04 0 75 l s    Cooling capacity   Compressor absorbed power   Mixture flow     From the available static pressure the value corresponding to  the new mixture flow  0 75  5    gt 137 kPa  can be read     The correct available static pressure corresponding to a 20   glycol mixture will be     Available static pressure  137 x 0 95   130 kPa     VERWENDUNG VON  WASSER ETHYLENGLIKOL MISCHUNGEN    Die Verwendung von Ethylenglykol Wassergemisch ist  empfohlen  um die Eisbildung an den Warmetauschern und  Speichern der Kaltwassersatze zu vermeiden    Die Verwendung von Mischungen mit niedrigem Gefrierpunkt  bewirkt eine Anderung der wichtigsten thermodynamischen  Betriebseigenschaften der Gerate  Die Parameter von besonderer  Bedeutung bei Verwendung dieser Mischungen sind folgende       Kalteleistung     Verdichter Leistungsaufnahme    Mischungsdurchflu       Ext  statische Pressung    In der unten stehenden Tabelle sind die Werte der  Korrekturkoeffizienten bez  glich der normalgebr  uc
18. CONDENSANTE EVAPORANTE  VALVOLA DI RITEGNO ONE WAY VALVE R  CKSCHLAGVENTIL VANNE DE RETENTION  EVAPORATORE EVAPORATOR VERDAMPFER EVAPORATEUR  FILTRO DISIDRATATORE FILTER DRIER TROCKNERFILTER FILTRE DESHYDRATEUR  RICEVITORE DI LIQUIDO LIQUID RECEIVER FL  SSIGKEITSSAMMLER RESERVOIR DE LIQUIDE  COMPRESSORE COMPRESSOR VERDICHTER COMPRESSEUR  MANOMETRO ACQUA WATER GAUGE WASSER MANOMETER MANOMETRE EAU  ELETTROPOMPA ELECTRICAL PUMP ELEKTRISCHE PUMPE POMPE ELECTRIQUE  ELETTROVENTILATORE ELECTRIC FAN MOTOR ELEKTROVENTILATOR ELECTROVENTILATEUR  PRESSOSTATO DIFFERENZIALE DIFFERENTIAL PRESSURE SWITCH DIFFERENZDRUCKSCALTER PRESSOSTAT DIFFERENTIEL  VALVOLA 4 VIE 4 WAY VALVE VIERWEGE UMSCHALTVENTIL VANNE 4 VOIES  SCARICO ACQUA WATER DRAIN WASSER ENTALDEN VIDANGE D EAU  PRESSOSTATO ALTA MAN  HIGH PRESS SWITCH M R  HOCHDRUCKSCHALTERMAN PRSS  HAUTE PRESS  MAN   PRESSOSTATO BASSA AUT   accessorio  LOW PRESS  SWITCH A R   accessory  NIEDERDRUCKSCHALT  AUT   Zubeh  r  PRESS  BASSE PRESS  AUT   accessoire   SERBATOIO STORAGE TANK SPEICHERBEH  LTER BALLON TAMPON  SONDA DI LAVORO WORKING PROBE WASSERTEMP  F  HLER SONDE DU TRAVAIL  SONDA ANTIGELO ANTIFREEZE PROBE FROSTSCHUTZF  HLER BNUTZERSEITE SONDE ANTIGEL  TRASDUTTORE DI PRESSIONE PRESSURE TRANSDUCER DRUCKGEBER TRANSDUCTEUR DE PRESS  VASO DI ESPANSIONE EXPANSION VESSEL AUSDEHNUNGSGEFAB VASE D   EXPANSION  VALVOLA DI SICUREZZA 300 kPa SAFETY VALVE 300 kPa SICHERHEITSVENTIL 300 kPa SOUPAPE DE SECURITE 300 kPa  VALVOLA DI SICUREZZA SAFETY VALVE SICHE
19. CONSIGLI PRATICI DI INSTALLAZIONE    Posizionamento      Osservare scrupolosamente gli spazi di rispetto indicati a catalogo      Verificare che non vi siano ostruzioni sull   aspirazione della batteria alettata  e sulla mandata dei ventilatori      Posizionare l   unit   in modo da rendere minimo l impatto ambientale  emissione  sonora  integrazione con le strutture presenti  ecc      Collegamenti elettrici      Consultare sempre loschemaelettrico incluso nel quaderno tecnico  ovesono sempre  riportate tutte le istruzioni necessarie per effettuare i collegamenti elettrici      Dare tensione all   unit    chiudendo il sezionatore  almeno 12 ore prima  dell avviamento per permettere l alimentazione delle resistenze del carter   ove presenti  Non togliere tensione alle resistenze del carter  ove presenti   durante i brevi periodi di fermata dell   unit        Prima di aprire il sezionatore fermare l   unit   agendo sugli appositi interruttori  di marcia  o in assenza sul comando a distanza      Prima di accedere alle parti interne dell   unit    togliere tensione aprendo il  sezionatore generale      E    vivamente raccomandata l installazione di un interruttore magnetotermico a  protezione della linea elettrica di alimentazione  a cura dell   installatore     Collegamenti elettrici da effettuare      Cavo di potenza tripolare   neutro   terra  Consenso esterno  Riporto  allarme a distanza    Collegamenti idraulici      Sfiatare accuratamente l impianto idraulico  apompaspenta 
20. RHEITSVENTIL SOUPAPE DE SECURITE  VALVOLA D ESPANSIONE EXPANSION VALVE EXPANSIONSVENTIL SOUPAPE D EXPANSION    12    UTILIZZO DI MISCELE ACQUA GLICOLE  ETILENICO    Il glicole etilenico miscelato all   acqua di circolazione viene  impiegato per prevenire laformazione di ghiaccio negli scambiatori  dei refrigeratori e nei serbatoi inseriti nei circuiti idraulici       impiego di miscele a basso punto di congelamento produce  una variazione delle principali caratteristiche termodinamiche  delle unit      parametri che interessano  in quanto di impiego  comune  sono i seguenti       resa frigorifera     potenza assorbita compressore    portata della miscela     prevalenza utile    Per semplicit   si riassumono in una tabella i valori dei coefficienti  correttivi per le percentuali aggiuntive di glicole etilenico di uso  comune     OPERATION WITH ETHYLENE GLYCOL  MIXTURES    The use of ethylene glycol mixtures is intended to prevent freezing  in chillers heat exchanger and tanks    The use of low freezing point mixtures causes a modification  in the thermodynamic properties of the units  The major  parameters affected by the use of glycol mixtures are the  following       cooling capacity     compressor absorbed power    mixture flow     available static pressure    In the table below are reported the correction factors referred  to the most common ethylene glycol mixtures     Ethylene glycol percent by weight             Percentuale di glicole etilenico in                   10 2
21. Refrigeratori d acqua e pompe di calore    RPE X   HPE X 19 25        a  Tr  W  A   lt          gt              lt   2      Q      42  2  12   N         x   2              Ay  ACCORRONI    C  Cuc fe Techno  234    RPE X   HPE X 19 25                                                                                                                                                                                                                               INDICE Pag   Descrizione generale 4  Versioni 4  Caratteristiche costruttive 4  Accessori forniti separatamente 4  Dati tecnici generali 6  Rese in raffreddamento 7  Rese in riscaldamento 8  Prevalenza utile pompa di circolazione 9  Coefficienti correttivi per fattori di  sporcamento 10  Limiti di funzionamento 10  Schema circuito frigorifero e idraulico   unita per solo raffreddamento 11   unita a pompa di calore 12  Utilizzo di miscele acqua glicole etilenico 13  Livelli di pressione sonora 15  Dimensioni di ingombro  pesi  spazi di  rispetto e collegamenti idraulici 17  Schemi elettrici 18  Legenda schemi elettrici 19  Consigli pratici per l   installazione 20   INDEX Seite  Allgemeine Eingeschaften 5  Bauvarianten 5  Konstruktionsmerkmale 5  Lose mitgelieferten Zubeh  re 5  Allgemeine technische Daten 6  K  lteleistungen 7  Heizleistungen 8  Externe statische Pressung der Umlaufpumpe 9  Korrekturkoeffizienten fur  Verschmutzungsfaktoren 10  Einsatzbereich 10  Wasser und Kaltekreislaufschema   nur zu K  hlung Einheiten 11   W
22. durchfluB  0 73 l s   Ext  statische Pressung  140 kPa    Mit einem Zusatz von 20  Glykol und unter Verwendung der oben  angef  hrten Koeffizienten    ndern sich diese Werte wie folgt     15 3 x 0 950   14 5 kW  4 7    0 995   4 67 kW  0 73    1 04   0 75 l s    K  lteleistung   Verdichter Leistungsaufnahme   Mischungsdurchflu       Von der Druckverlust Kurve kann der dem neuen  Durchflu  wert entsprechende Ext  statische Pressung  0 75 1   s    gt  137 kPa  abgelesen werden     Der korrekte Ext  statische Pressung bez  glich einer 20   Glykolmischung wird also sein     Ext  statische Pressung  137 x 0 95   130 kPa      15 5  21 5  32 5 Temp  rature de cong  lation    C    0 93 0 91 0 88 Coeff  corr  puissance frigorifique   0 990 0 985 0 975 Coeff  corr  puissance absorb  e compresseur  1 08 1 14 1 20 Coeff  correcteur d  bit solution   0 92 0 84 0 78 Coeff  corr  pression utile   EXEMPLE DE CALCULATION    Pour utiliser correctement les coefficients indiqu  s dans le  tableau  voici un exemple pratique  On suppose vouloir  intervenir sur un groupe d   eau glac  e RPE X 19 dont les  conditions nominales sont les suivantes      Puissance frigorifique   15 3 kW  Puissance absorb  e compresseur  4 7 kW  D  bit d   eau   0 73 l s   Pression utile  140 kPa    En ajoutant 20   de glycol  les valeurs se modifieront en  utilisant les coefficients indiqu  s dans le tableau      15 3x 0 950   14 5 kW  4 7 x 0 995   4 67 kW  0 73x 1 04  0 75 l s    Puissance frigorifique    Puissance ab
23. e LIMITES DE  min max FONCTIONNEMENT  25 45 Temp  rature eau entr  e  30 50 Temp  rature eau sortie  3 10 Ecart de temp  rature   10 20 Temp  rature air ext  rieur  _ Temp  rature minimum de l eau glac  e  avec glycol  Pression maximun d utilisation      changeur c  te eau    10    SCHEMA CIRCUITO FRIGORIFERO E IDRAULICO UNITA     PER SOLO RAFFREDDAMENTO    HYDRAULISCHER ANSCHLUB UND K  LTESCHEMA DER    KALTWASSERS  TZE    CA  CAR  EW  FD  MC  MN  MP  MV  PD  SC  SPH  SPL  ST  ST1  ST2  TRGV  VE  VSI  VT    11    TRGV    SPH    DIAGRAM    REFRIGERANT AND HYDRAULIC CHILLER CIRCUIT    SCHEMAT DU CIRCUIT HYDRAULIQUE ET FRIGORIFIQUE    GROUPE DE PRODUCTION D   EAU GLACEE                                                 DENOMINAZIONE DESIGNATION BEZEICHNUNG DESIGNATION  BATTERIA CONDENSANTE CONDENSING COIL VERFLUSSIGER VERDAMPFER BATTERIE COND    CARICO LOAD LAST CHARGE   EVAPORATORE EVAPORATOR VERDAMPFER EVAPORATEUR   FILTRO DISIDRATATORE FILTER DRIER TROCKNERFILTER FILTRE DESHYDRATEUR  COMPRESSORE COMPRESSOR VERDICHTER COMPRESSEUR  MANOMETRO ACQUA WATER GAUGE WASSER MANOMETER MANOMETRE EAU  ELETTROPOMPA ELECTRICAL PUMP ELEKTRISCHE PUMPE POMPE ELECTRIQUE  ELETTROVENTILATORE ELECTRIC FAN MOTOR ELEKTROVENTILATOR VANNE THERMOSTATIQUE  PRESSOSTATO DIFFERENZIALE DIFFERENTIAL PRESSURE SWITCH DIFFERENZDRUCKSCALTER PRESSOSTAT DIFFERENTIEL  SCARICO ACQUA WATER DRAIN WASSER ENTLADEN VIDANGE D EAU  PRESSOSTATO ALTA MAN  HIGH PRESS SWITCH M R  HOCHDRUCKSCHALTERMAN PRSS  HAUTE PRESS  MAN      
24. ge d   air manuel  r  servoir  calorifug    pompe  soupape de s  ret    3 bar   manom  tre  robinet  de charge et d  charge installation et vase d   ex pansion inser  e a  l interieur de l   unit       ACCESSOIRES FOURNIS SEPAREMENT   PB   Pressostat basse pression    r  armement manuel   CR   Tableau de commandes    distance a ins  rer dans un envi   ronnement pour la commande a distance de l unit    avec fonctions  identiques a celles ins  r  es dans la machine   IS   Interface de s  rie RS 485 pour branchement    syst  me de  contr  le et de supervision centralis  es   RP   R  seaux de protection batterie en acier avec traitement  cataphor  se et vernissage     DATI TECNICI GENERALI    ALLGEMEINE TECHNISCHE DATEN    TECHNICAL DATA    CARACTERISTIQUES TECHNIQUES GENERALES    Tabella dati tecnici refrigeratori e pompe di calore RPE X HPE X 19  25                                                                               DESCRIZIONE UM RPE HPE X 19 RPE HPE X 22 RPE HPE X 25  Potenza frigorifera  1  kW 15 3 18 6 20 5  Potenza assorbita  1  kW 5 0 6 0 6 6  Potenza termica  2  kW 18 8 21 9 24 4  Potenza assorbita  2  kW 6 2 7 1 8 0  ESEER W W 3 57 3 66 3 68  N   compressori 1   Tipo compressore Scroll   Portata acqua l h 2 628 3 204 3 528  Prevalenza utile kPa 123 90 80  Volume serbatoio   50   Volume vasi d   espansione   3 4   Attacchi idraulici 1      Ventilatori n   x kW 2   0 14   Portata aria m  h 6 408 5 904  Alimentazione elettrica 400V 3 N 50Hz   Corrente max funz  A
25. hlichen  Athylenglykolmischungen dargestellt     UTILISATION DE LA SOLUTION EAU GLYCOL  ETHYLENIQUE    Le glycol   thyl  nique m  lang   al eau d utilisation est employ   pour  pr  venir la formation de la glace dans les   changeurs et ballons  des groupes  ins  r  s dans les circuits hydrauliques    L   emploi de cette solution a bas point de cong  lation produit une  variation des principales caract  ristiques thermodynamiques  de fonctionnement de la machine  Les parametres affect  s par  l utilisation de glycol sont les suivants        puissance frigorifique     puissance absorb  e compresseur    d  bit de la solution     Pression utile    A cet effet  sont r  capitul  s dans le tableau ci dessous les  valeurs des coefficients de correction pour les pourcentages  d   adjonction de glycol   thyl  nique d   utilisation plus  commune     Pourcentage de glycol en poids    30 40 50                 lykol Prozent pr  een  coy ge 0 10 20  Gefriertemperatur    C  0  4 5  9 5  Korr  koeff  K  lteleistung 1 0 975 0 95  Korr  koeff  Verdichter Leistungsaufnahme    1 01 0 995  Korr  koeff  Mischungsdurchflu   1 1 01 1 04  Korr  koeff  Ext  statische Pressung 1 0 96 0 95  BERECHNUNGSBEISPIEL    Ein Beispiel kann Ihnen helfen  um die oben stehenden  Koeffizienten korrekt zu interpretieren    Man nehme an  man mu   einen Kaltwassersatz RPE X 19  einsetzen  dessen Leistungen unter Nennbedingungen die  folgenden sind     K  lteleistung  15 3 kW  Verdichter Leistungsaufnahme  4 7 kW  Wasser
26. l  gbar  ist auch w  hrend der Stillstandszeit des Ger  tes  sicherzustellen      Vor dem   ffnen der Sicherungen das Ger  t ausschalten  durch Bet  tigung  des entsprechenden Hauptschalters  oder   ber die Fernbedienung      Vor dem   ffnen des Ger  tes ist die Spannungsversorgung zu unterbrechen       Die Installation der Hauptsicherungen ist durch den Elektroinstallateur  vorzunehmen    Auszuf  hrende elektrische Anschl  sse      Anschlu  kabel 5 Adern  3 Phasen  Neutral  Schutzleiter  Externe  Bedieneinrichtung  Alarmfernmeldung    Hydraulische Anschl  sse      Sorgf  ltig das hydraulische System bei abgeschalteten Pumpen entl  ften   Dieser Vorgang ist besonders wichtig  da auch kleine Luftblasen eine  Vereisung des Verdampfers bewirken k  nnen      Das hydraulische System ist w  hrend der Winterpause zu entleeren  oder  entsprechende Frostschutzmischung anzuwenden      Zum Schutz des Platten W  rmetauschers ein Metallfilter bei Einheitseintritt  immer einbauen      Den hydraulischen Kreislauf unter Einbezeichung der in den empfohlenen  Diagrammen angegebenen Bestandteile  Entl  ftungsventile  Absperrventile   Ausgleichsventil  schwingungsd  mpfende Kupplungen  schlie  en    Inbetriebnahme und Wartung      Bitte strikt die Betriebs  und Wartungsanleitung befolgen  Alle darin  beschriebenen Arbeiten d  rfen nur von Fachleuten ausgef  hrt werden     INSTALLATION RECOMMENDATIONS    Location      Strictly allow clearances as indicated in the catalogue      Ensure there are n
27. o obstructions on the air suction and discharge  side      Locate the unit in order to be compatible with environmental requirements   sound level  integration into the site  etc      Electrical connections      Check the wiring diagram enclosed with the unit  in wich are always present  all the instructions necessary to the electrical connections      Supply the unit at least 12 hours before start up  in order to turn crankcase  heaters  ifavailable  on  Do not disconnect electrical supply during temporary  stop periods  i e  week ends       Before opening the main switch  stop the unit by acting on the suitable  running switches or  if lacking  on the remote control      Before servicing the inner components  disconnect electrical supply by  opening the main switch      The electrical supply line must be equipped with an automatic circuit breaker   to be provided by the installer      Electrical connections to be done      Three wire power cable   neutral cable   ground cable  External interlock   Remote alarm signalling    Hydraulic connections      Carefully vent      system  with pump turned off  by acting on the vent valves   this procedure is fundamental  little air bubbles can freeze the evaporator  causing the general failure of the system      Drain the system during seasonal stops  wintertime  or use proper mixtures  with low freezing point      Always install a metallic filter on the unit inlet in order to protect the plate  exchanger      Install the hydraulic ci
28. one automatica delle seguenti funzioni   regolazione della temperatura dell acqua  protezione antigelo  tempo   rizzazione del compressore  reset allarmi  contatto cumulativo d allar   me per segnalazione remota  commutazione locale o remota del ciclo  raffreddamento riscaldamento nelle pompe di calore  visualizzazione  su display per  ciclo di funzionamento  raffreddamento o riscaldamen   to   compressore richiesto attivato  temperatura dell acqua di ritorno  dell impianto  set temperatura e differenziali impostati  codice allarmi   Dispositivo elettronico proporzionale per l attenuazione del livello  sonoro  ottenuta mediante regolazione in continuo della velocit   di  rotazione dei ventilatori  tale dispositivo permette anche il funzio   namento dell   unit   in raffreddamento fino a temperature dell   aria  esterna di  20   C     Versione RPE X  Circuito frigorifero  Il circuito  realizzato in tubo di rame  include   filtro disidratatore  valvola d espansione e pressostato di alta a  riarmo manuale   Circuito idraulico  Il circuito  realizzato in tubo di rame  include   pressostato differenziale acqua  valvola di sfiato aria manuale   serbatoio coibentato  pompa  val vola di sicurezza  3 bar    manometro  rubinetto di carico e scarico impianto e vaso di  espansione inserito all   interno del serbatoio    Versione HPE X  Circuito frigorifero  Il circuito  realizzato in tubo di rame  include   filtro disidratatore bidirezionale  valvole d   espansione  valvole di  ritegno  
29. osizionato ad 1 m dall unit   e  1 5 m da terra  nei punti in figura     sound pressure level measured in  free field conditions  at 1m from  the unit et 1 5 m from the floor level   in the point on the picture           15    NIVEAUX DE PRESSION SONORE    SCHALLDRUCKPEGEL  OKTAVBANDER BANDES D OCTAVE  Hz  TOTAL  MOD TOTALE  i 63 125 250 500 1000 2000 4000 8000 dB A    dB   dB   dB   dB   dB   dB   dB   dB   Lb    La Lb La Lb La Lb La Lb La Lb La Lb La Lb La Lb La  49 550 51 5 56 3 51 0 546 51 0 59 7 47 0 521 47 5 47 5 445 470 44 0 470 47 0 59 3 53 2  22 55 0 52 0 56 3 51 0 54 6 51 5 597 47 0  52 2 48 0 47 5 44 5 470 440 470 470 59 3 53 4  25 55 5 52 5 56 7 51 5 54 9 52 0 59 8 471 52 2 48 5 475 44 7 47 3 44 3 47 3 47 3 59 4 53 7    OKTAVBANDER BANDES D OCTAVE  Hz  TOTAL  MOD  63 125 250 500 1000 2000 4000 8000 ee   dB   dB   dB   dB   dB   dB   dB   dB  2     Lc Ld Lc Ld Lc Ld Lc Ld Lc Ld Lc Ld Lc Ld Lc Ld Lc Ld  19 56 0 53 0 56 0 52 0 56 0 51 5 56 5 53 5 535 50 0  50 0 46 0   46 0 46 5 470 47 5 58 6 55 9  22 56 0 53 0   56 0 51 5 56 0 51 5 56 5 54 0 540 50 0  50 0 46 0  46 5 46 0 470 47 0   58 8 55 9  25 56 5 53 5  56 5 52 0 56 5 52 0 571 54 1 541 50 1 50 2 46 2 46 7 46 3 47 3 47 3   591 56 1    Les valeurs de pr  ssion sonore  sont relev  s en champ libre avec  sonom  tre positionn      1    de  Punit   et 1 5 m du sol  comme  desous indiqu      L  a  b  c  d   Die Werte des Schalldruckpegels L  a  b  c  d    sind im Freifeld in 1 5 m H  he im  Abstand von 1    vom Ger  t e
30. plant charge and  discharge shut off valve and expansion vessel inserted in the  storage tank    HPE X Version   Refrigerant circuit  The circuit  in copper tubing  includes  bi direc   tional dryer filter  expansion valves  check valves  4 ways reverse  valve  manual reset high pressure switch     Water circuit  The circuit  in copper tubing  includes  water  differential pressure switch  manual air release valve  insulated  tank  pump  safety valve  3 bar   gauge  plant charge and  discharge shut off valve and expansion vessel inserted in the  storage tank     SEPARATELY SUPPLIED ACCESSORIES   PB   Manual reset low pressure switch   CR   Remote control panel to be inserted in the room for remote  control of the unit  with the same functions as that inserted in the  machine   IS   RS485serial interface for connection to controls and central   ized supervision systems   RP   Coil protection guards in steel with cataphoresis treatment  and painting     ALLGEMEINE EIGENSCHAFTEN    Luftgek  hlte Fl  ssikeitsk  hler mit   Axialventilatoren f  r  Aussenaufstellung  Die Produktpalette besteht aus 3 Modellen  die  K  lteleistungsbereich von 15 bis 20 kW abdecken     BAUVARIANTEN   RPEX   nur zur K  hlung mit Speicher und Pumpe    HPEX   reversibler W  rmepumpe mit Speicher und  Pumpe  KONSTRUKTIONSMERKMALE     Struktur  Mittragendem rahmen aus Peraluman  verzinktem Blech und  mit Gummi Schwingungsd  mpfer auf dem Grundrahmen  Schrauben  aus Edelstahl    Verdichter  3 phasisch Scroll
31. rcuit including all the components indicated in the  recommended hydraulic circuit diagrams  vent valves  balancing valve   shut off valves flexible connections  etc      Start up and maintenance operations      Strictly follow what reported in use and maintenance manual  All these  operations must be carried on by trained personnel only     CONSEILS PRATIQUES POUR L   INSTALLATION    Mise en place      Observer scrupuleusement les espaces pour l entretien tels qu indiqu  s  pr  c  demment      V  rifier qu il n existe aucune obstruction sur l aspiration de l air au travers  de la batterie ailett  e et sur le refoulement des ventilateurs      Positionner l unit   de mani  re    n   affecter qu au minimum l environnement     mission sonore  integration sur le site  etc      Raccordements   lectriques      Consulter toujours le sch  ma   lectrique joint a la machine ou sont  toujours report  es toutes les instructions n  cessaires pour effectuer les  raccordements   lectriques      Mettre la machine sous tension  en fermant le sectionneur  au moins 12 h avant  le d  marrage pour permettre l alimentation des r  sistances du carter ou il y a   Ne pas supprimer l alimentation aux r  sistances du carter  ou il y a  durant les  cours arr  ts de la machine      Avant d   ouvrir le sectionneur arr  ter l   unit   en agissant sur les interrupteurs  pr  vus a cet effet ou bien sur la commande a distance      Avant d acc  der aux parties internes de l unit    couper l alimentation    lec
32. rfa  t  worden  wie unten abgebildet              16    DIMENSIONI DI INGOMBRO  PESI  SPAZI DI DIMENSIONS  WEIGHTS  CLEARANCES                                                                                                                                                                                                                                              RISPETTO E COLLEGAMENTI IDRAULICI AND HYDRAULIC CONNECTIONS  AUSSENMABE  GEWICHTE  RAUMBEDARF ENCOMBREMENTS  POIDS  ESPACES  UND HYDRAULISCHE ANSCHLUBE POUR ENTRETIEN ET RACCORDEMENTS  HYDRAULIQUES  A    1164 nn        1164    WASSEREINTRITT       1 ENTRES BAU  i ba UU  4   SFIATO       NUN                          inn     ENTLUFTUNG o mmm mmm  Loa REMFLARO Q a  a iii ai i  8 5                  USCITA ACQUA    iM Ce id ii iii      eee Re GE  ei yA  E     IIIIIIIIIIIIIIIIII IIIII  I  IIUI  IIIIIIZ  Bu SS     LE t 1         RUBINETTO DI SCARICO as  SCARICO CONDENSA  WP  110 SOUPAPE DE DECHARGE    CONDENSATE DRAIN  WP   KONDENSWASSERENTLEERUNG  WP   EVACUATION DES CONDENSATS  WP  GE TO        _  CHARGE SHUT OFF VALVE 1 2      DRUCKVENTIL  Sg              ENTRATA LINEA ELETTRICA ROBINET DE CHARGE 4  I I I I I I I I I I VOLTAGE SUPPLY INLET  o ELEKTRISCHER ANSCHLUSS     ENTREE ALIMENTATION ELETRIQUE  HANNAH  200      800       3  ce E E  Peso in funzione   Operating weight Entrata acqua   Water inlet Uscita acqua   Water outlet  MOD Betriebsgewicht   Poids en fonction Wassereintritt   Entr  e eau Wasseraustritt   Sortie eau
33. rmonische Str  me    Filtre pour courants harmoniques       Fusibile pompa    Pump fuse    Sicherung pumpe    Fusible du pompe       Controllo sequenza fasi    Control phase relay    Phasenrelais    Controle de phase                                  Teleruttore compressore Compressor contactor Verdichter Schutz 2    Teleruttore            Pump contactor Pumpen Schutz Telerupteur pompe  Compressore Compressor Verdichter Compresseur   Motore pompa Pump motor Pumpemotor Pompe   Motore ventilatore Fan motor Geblase Ventilateurs   Motore ventilatore Fan motor Geblase Ventilateurs  Salvamotore compressore Compressor overload ee Sauf motor compresseur  Sezionatore generale Main switch Hauptschalter Interrupteur general  Resistenza compressore                          Kubelwannenheizung ar qu  Pressostato alta pressione High pressure switch Hochdruckschalter 2           Pressostato bassa    Low pressure    Niederdruckschalter    Pressostat de basse                pressione  accessorio  switch  accessory   Zubeh  r  pression  accessoire   Pressostato differenziale acqua 2  SE 1  Pressostat diff  rentiel eau  Sonda raziometrica 0 5 V  probe 0 5 V  Fuhler 0 5 V  sonde   Sonda di lavoro Working probe Wassertemp  fuhler Sonde du travail   Sonda antigelo Antifreeze probe Frostschutzfuhler Sonde antigel       Trasformatore    Control transformer    Trafo    Trasformateur       Valvola di inversione ciclo  WP     4 way valve  WP     4 wege ventil  WP     vanne d inversion a  4 voies  WP     
34. s shown  above     f1  Facteurs de correction pour la puissance rendue            Facteurs de correction pour la puissance absorb  e du compresseur   Les performances des unit  s indiqu  es dans les tableaux sont donn  es  pourla condition d     changeur propre                                             0   Pour  des valeurs diff  rentes du facteur d   encrassements  les performances  annonc  es seront corrig  es en utilisant les facteurs indiqu  s     Raffreddamento   Cooling Riscaldamento   Heating                LIMITI DI FUNZIONAMENTO      OPERATING RANGE  min max min max   Temperatura acqua in ingresso   C 8 20 25 45 Inlet water temperature   Temperatura acqua in uscita   C 5 15 30 50 Outlet water temperature   Salto termico acqua   C 3 9 3 10 Water thermal difference   Temperatura aria esterna      20 46  10 20 Ambient air temperature   Minima temperatura dell   acqua      8 _ Minimun chilled water outlet    refrigerata con l   impiego di glicole    temperature with glycol mixture       Max pressione di esercizio lato              acqua scambiatore    K  hlung   Refroidissement    300 Max operating pressure heat                   EINSATZBEREICH e  min max   Wassereintrittstemperatur      8 20  Wasseraustrittstemperatur Ye 5 15  Wassertemperaturdifferenz   C 3 9  Umgebungstemperatur   C  20 46  Min  Temperatur des gek  hlten   C 8  Wasser mit Verwendung von Glykol  Max  Betriebsdruck   kPa    Warmetauscher  Wasser Seite    300    exchanger water side  Heizung   Chauffag
35. slauf aus Kupferrohren mit Entfeuchtungsfilter  Ex   pansionsventil und Hochdruckschalter mit manueller R  ckstellung     Wasserkreislauf  Wasserkreislauf aus Kupferrohren mit differenti   alem Wasserdruckschalter  manuellem Entl  fungsventil  Beh  lter  mit Isolierung  Pumpe  Sicherheits ventil  3 bar   Manometer   Anlage Druck und Abfluss mit Absperventiie und  Ausdehnungsgef     in dem Speicher eingebaut   HPE X bauvariante   K  ltekreislauf  Kreislaufaus Kupferrohren mit zweiseitig gerichtetem  Entfeuchtungsfilter  Expansionsventil  R  ckschlagventilen  4 Wege   Umschaltventil und Hochdruckschalter mit manueller R  ckstellung     Wasserkreislauf  Wasserkreislauf aus Kupferrohren mit differenti   alem Wasserdruckschalter  manuellem Entl  fungsventil  Beh  lter  mit Isolierung  Pumpe  Sicherheits ventil  3 bar   Manometer   Anlage Druck und abfluss mit  absperventile und  Ausdehnungsgef     in dem Speicher eingebaut     LOSE MITGELIEFERTEN ZUBEH  RE   PB   Niedrigdruckschalter mit manuellem Reset   CR   Fernbedienung  die am Standort installiert wird und von der  aus eine Fernsteuerung der Einheit m  glich ist  Mit den gleichen  Funktionen wie das Ger  t   IS   Serielle Schnittstelle RS 485 f  r den Anschluss an Kontrolll   systeme oder zentrale Supervisor   RP   Schutzgitter Verfl  ssigerregister aus Stahl mit Kataphore   sebehandlung und Lackierung     DESCRIPTION GENERALE    Groupe d   eau glac  e a condensation a air avec ventilateurs axiaux  pour installation a l   ext
36. sorb  e compresseur   D  bit solution      Sur la courbe des pertes de charge on rel  ve la pression  utile  correspondante au valeur nouveau de d  bit  0 75 l s     gt  137 kPa      La pression utile  correcte relative a un solution de glycol de 20    sera donc      Pression utile  137 x 0 95   130 kPa     14    LIVELLI DI PRESSIONE SONORA    SOUND PRESSURE LEVEL  BANDE D   OTTAVA OCTAVE BANDS  Hz  TOTALE  MOD TOTAL    63 125 250 500 1000 2000 4000 8000 dB A    dB   dB   dB   dB   dB   dB   dB   dB     La Lb La Lb La Lb La Lb La Lb La Lb La Lb La Lb La Lb  49 550 51 5 563 510  54 6 510 59 7 47 0   52 1    47 5   47 5 44 5   470 44 0 47 0 47 0 59 3 53 2  22    55 0 52 0 56 3 51 0 546 51 5   59 7 47 0   52 2 48 0 47 5 44 5 47 0 44 0   47 0 47 0  59 3 53 4    25 55 5 52 5 56 7 51 5   54 9 52 0   59 8 47 1   52 2 48 5 47 5 44 7 47 3 44 3   47 3 47 3 594 53 7    BANDE D   OTTAVA OCTAVE BANDS  Hz     TOTALE  MOD  63 125 250 500 1000 2000 4000 8000 pe   dB   dB   dB   dB   dB   dB   dB   dB             Lda Bice Eds Le  eh   Le del   Le e  leo           el Le deje o  19 56 0 53 0 56 0 52 0 56 0 51 5 56 5 53 5 53 5 50 0 50 0 46 0 46 0 46 5 470 475 58 6 55 9  22    56 0 53 0 56 0 51 5 56 0 51 5  56 5 54 0   54 0 50 0 50 0 46 0   46 5 46 0   47 0 47 0  58 8 55 9    25 56 5 53 5   56 5 52 0 56 5 52 0   571 54 1   54 1 50 1 50 2 46 2 46 7 46 3   47 3 47 3   59 1 56 1    L  a  b      d   valori di pressione sonora rilevati in L  a  b      d    condizioni di campo libero con fono   metro p
37. tilation and special wing profile  they are directly  coupled to external rotor motors with protection grade IP44  and a  safety fan guard fitted on discharge air flow     Condenser  Copper tubes and aluminium finned coil  complete with  moisture drain pan in the heat pump version     Evaporator  In AISI 316 stainless steel brazewelded plates type   built in the storage tank    Electrical panel  Includes  main switch with door lock device  fuses   filter for harmonic current  compressor contact and pump contact   Microprocessor to control following functions  regulation of the  water temperature  antifreeze protection  compressor timing  alarm  reset  potential free contact for remote general alarm  local or  remote cooling   heating changeover  operating in heat pump    visual system with digital display  running cycle  cooling or heating    compressor delay relay on  inlet water temperature  set point and  differential setting  alarm decodification     Electronic proportional device to decrease the sound level  with a  continuous regulation of the fan speed  This device allows also the  cooling functioning of the unit by external temperature till  20  C     RPE X Version  Refrigerant circuit  The circuit  in copper tubing  includes  dryer filter   expansion valves and manual reset high pressure switch     Water circuit  The circuit  in copper tubing  includes  water  differential pressure switch  manual air release valve  insulated  tank  pump  safety valve  3 bar   gauge  
38. trique en ouvrant le sectionneur g  n  ral      Il est vivement recommand   d   installer un disjoncteur magn  to thermique       protection de la ligne d   alimentation   lectrique  a la charge de l installateur     Raccordements   lectriques a effectuer      Cable de puissance tripolaire   neutre   terre  Contacts ext  rieurs  Report  a distance des alarmes    Raccordements hydrauliques      Purgeravec soin l installation hydraulique  pompe hors service  en intervenant  sur les purgeurs  Cette procedure est particuli  rement importante  car la  pr  sence m  me de petites bulles d air peut causer le gel de l   vaporateur      Vidanger l installation hydraulique pendant l hiver ou utiliser un m  lange  antigel approprie      Installer toujours un filtre metallique a l entr  e du group au fin de proteger  l echangeur    plaques      R  aliser le circuit hydraulique en incluant tous les composants indiqu  s  dans les sch  mas relatifs  purgeurs  vannes d arr  t  robinet d   quilibrage   jonctions antivibratiles  etc      Mise en service et entretien      Se tenir scrupuleusement a ce qui est indiqu   dans le manuel d utilisation et  d   entretien  Ces op  rations seront toutefois effectu  es par du personnel qualifie     20    NOTE    NOTE    B ACCORRONI A2B Accorroni E G  s r l   AL Gemeng ee Via d   Ancona  37   60027 Osimo  An    Tel  071 723991 r a    Fax 071 7133153  Climate Technology web site  www accorroni it   e mail  a2b accorroni it    
39. valvola di inversione a quattro vie e pressostato di alta a  riarmo manuale   Circuito idraulico  Il circuito  realizzato in tubo di rame  include   pressostato differenziale acqua  valvola di sfiato aria manuale   serbatoio coibentato  pompa  valvo la di sicurezza  3 bar    manometro  rubinetto di carico e scarico impianto e vaso di  espansione inserito all   interno del serbatoio     ACCESSORI FORNITI SEPARATAMENTE   PB   Pressostato bassa pressione a riarmo manuale   CR   Pannello comandi remoto da inserire in ambiente per il co   mando a distanza dell   unit    con funzioni identiche a quello inserito  in macchina   IS   Interfaccia seriale RS 485 per collegamento a sistemi di  controllo e di supervisione centralizzati   RP   Reti protezione batteria in acciaio con trattamento di cata   foresi e verniciatura     GENERAL DESCRIPTION    Air cooled water chiller units  with axial fans for outdoor installation   The range consists of 10 models covering a cooling capacity from  15 to 20kW     VERSIONS   RPE X   cooling only with storage tank and pump  HPE X   reversible heat pump with storage tank and    pump    TECHNICAL FEATURES   Structure  With supporting frame  in peraluman  galvanized sheet and  with rubber shock absorbers on the frame  Stainless steel screws     Compressor  3 phase Scroll ermetic compressor  complete with  overload protection  klixon  embedded in the motor and crankcase   if needed  installed on rubber vibrations absorbing  Fans  Axial fan  type low ven
    