Home

Scheda tecnica

image

Contents

1. activated are visible by means of an icon on the above display area POSITIONING Keypad must be positioned e in an environment that is sheltered and protected from water and ra humidity m e onadry and level wall e in the proximity of the accesses to area to be protected E e in an inner location which is not subjected to excessive sudden rises falls in temperature and is protected by anti burglar system e at 160 cm height for normal installations or at 120 cm height for installations suitable to disabled users WIRING Keypad can be connected on bus either in a cascade or star Keypad position along bus is not important The overall length of all bus sections must not exceed 400 metres For wiring use 4 lead screened cable 2 leads for power supply and 2 leads for data connection Lead section must be chosen taking into account voltage drop caused by connection length In counting out overall system absorption also consider max consumption in keypad 110 mA INSTALLATION The 1067 026 keypad can be installed either on a wall or above a round flush mounting box or 3 seated built in case To install the keypad proceed as follows e Remove the keypad from the wall bracket by sliding it Fig 1 e Secure the support bracket to the wall with 6 mm plugs provided or on the built in case if available keeping the terminal strip downwards Fig 2 using the mountings A or B Avoid over tightening the screws in that they m
2. impianto antintrusione e a 160 cm di altezza per le installazioni normali o a 120 cm di altezza per le installazioni adatte a utenti diversamente abili CABLAGGIO La tastiera pu essere collegata sul bus a cascata o a stella La posizione della tastiera lungo il bus non ha importanza La lunghezza complessiva di tutte le tratte bus non deve superare 400 metri Per il cablaggio usare un cavo schermato a 4 conduttori 2 per l alimentazione e 2 per il collegamento dati La sezione dei conduttori deve essere scelta tenendo conto della caduta di tensione dovuta alla lunghezza del collegamento Nel conteggio generale dell assorbimento dell impianto considerare anche il consumo max della tastiera 110 mA INSTALLAZIONE La tastiera 1067 026 puo essere installata sia a parete sia sopra una scatola da incasso tonda o a 3 posti Per installare la tastiera fare quanto segue e Sganciare la tastiera dalla staffa a muro facendola slittare Fig 1 e Fissare la staffa di supporto alla parete tramite tasselli da 6 mm non forniti o sulla scatola da incasso qualora presente tenendo la morsettiera verso il basso Fig 2 utilizzando le predisposizioni A o B Evitare di stringere troppo le viti in quanto la conseguente curvatura della staffa potrebbe rendere difficoltoso l aggancio della tastiera alla staffa stessa e Perl antiasportazione utilizzare due tasselli a corredo in corrispondenza dei fori C e fissando anche il blocchetto D e C
3. inside it 3 The product type capacitive soft touch keys calls for the utmost care when cleaning the glass front side To ease this operation a function key T4 key has been provided which blocks the key functions for a preset time of 30 seconds thus enabling the cleaning operations Time will be struck on the display DS1067 058 7 D D A1A2 IN SSIS Fig 4 n Urme DS1067 058 UrmeL e LBT8997 URMET S p A Area tecnica 10154 TORINO ITALY servizio clienti 39 011 23 39 810 VIA BOLOGNA 188 C http www urmet com Telef 39 011 24 00 000 RIC AUT e mail info urmet com Fax 39 011 24 00 300 323
4. 0 Vdc 15 Vdc Rated current at 12 Vdc In standby mode only LED presence Network iii 32 mA medium consumption with backlight at lev 1 68 mA medium consumption with backlight at lev 4 nnne 110 mA maximum peak costi Mora prece 200 mA Total max length of the line Bus Control panel Peripherals are 400 m COMMUNICATION IV DO serial Urmet protocol Memory type for the programming nnne DATA FLASH Memory type for the vocabulary maintenance DATA FLASH Operating Emmerson E EET 10 C 40 C Operating medium relative humidity cesses nnn nennen nennen nnns 75 Storage temperature rang sssi chai exse area pas cc dio dane ainda damas 20 C 60 C Housing DrOLECHON EN TIE EO ee IP40 IK06 rg 460 g Dimensions W X AX c 160 x 130 x 23 5 mm WARNING 1 Detailed and complete information is contained in the installation programming and user manuals of the 1067 Control panel on the CD ROM supplied or downloaded directly from website www urmet com 2 DO NOT OPEN THE KEYPAD BOX all operations necessary for product installation and maintenance do not require interventions
5. Mod UrmeL 1067 DS1067 058 LBT8997 TASTIERA TOUCH CON LETTORE DI PROSSIMIT TOUCH KEYPAD WITH PROXIMITY READER Sch Ref 1067 026 rmel SIN CE ITALIANO DESCRIZIONE GENERALE Tastiera con frontale in vetro temprato tecnologia soft touch e display OLED Essa consente di comandare e programmare i sistemi della serie 1067 e dispone di un lettore di chiavi di prossimit 1067 332 di 1 ingresso ausiliare programmabile e di un microfono per l ascolto ambientale da telefono con interfaccia PSTN o GSM Dispone inoltre di un sensore di avvicinamento che permette di attivare le piene funzionalit del dispositivo che normalmente si trova in uno stato di basso assorbimento all avvicinarsi della mano nell area sopra il logo si accende la retroilluminazione il display visualizza le informazioni predefinite ed il lettore di chiavi diventa attivo Dopo 30 secondi dall ultima azione la tastiera ritorna nello stato di riposo Oltre ai normali tasti alfanumerici ed ai tasti di navigazione sono disponibili 4 tasti aggiuntivi le cui funzioni qualora attivate saranno visibili per mezzo di icone nell area del display immediatamente sovrastante POSIZIONAMENTO La tastiera deve essere posizionata e in un ambiente riparato e protetto da acqua e umidit aj e su una parete asciutta e piana e in prossimit degli accessi all area da proteggere 5 e in un luogo interno non soggetto a sbalzi eccessivi di temperatura e protetto dall
6. S FONIA BUS ALIMENTAZIONE E DATI ACQUISIZIONE DELLA TASTIERA Per l acquisizione della tastiera touch 1067 026 in fase di prima accensione premere il tasto T4 presente sul frontale vedi Fig 4 In caso si renda necessario cancellare i parametri della tastiera Reset agire nel seguente modo e aprire il contatto tamper sganciare la tastiera dalla relativa staffa e premere il tasto T4 per circa 5 secondi Per ulteriori informazioni su procedimento di acquisizione fare riferimento al manuale di installazione della centrale DS1067 058 3 INGRESSO DI ALLARME Collegare un eventuale sensore all ingresso ausiliare IN1 L ingresso e riferito a massa e pu essere programmato come NC NO Singolo bilanciamento e Doppio bilanciamento L ingresso pu anche gestire segnali veloci provenienti da sensori sismici o tapparelle in questo caso la modalit di collegamento fissa di tipo NC Per realizzare collegamenti con bilanciamento utilizzare resistenze da 2 7 kohm tolleranza 1 fornite in dotazione NC a negativo NO a negativo SINGOLO DOPPIO BILANCIAMENTO BILANCIAMENTO TASTIERA TASTIERA TASTIERA TASTIERA 50131 ALL ALL ALL ALL TAMPER NC SENSORE SENSORE SENSORE SENSORE ATTENZIONE l unica modalit di collegamento conforme alla normativa EN50131 quella a Doppio Bilanciamento Per ulteriori e dettagliate informazioni fare riferimento ai manuali delle centrali 1067 CARATTERISTICHE TECNICHE Tensione nominale di
7. alimentazione prelevati dalla centrale tramite bus 13 8 Vcc Tensione di funzionamento della tastiera n 10 Vcc 15 Vcc Corrente nominale assorbita a 12 Vcc Assorbimento a riposo solo LED presenza rete nnn 32 MA Assorbimento medio con retroillum a liV 1 esses menm nnne 68 mA Assorbimento medio con retroillum a liV 4 enne nnns 110 mA Assorbimento massimo di DICO 200 mA Lunghezza max complessiva della linea Bus Centrale periferiche eee 400 m TIPO Gi A PM seriale protocollo Urmet Tipo di memoria per il mantenimento della programmazione DATA FLASH Tipo di memoria per il mantenimento del vocabolario a DATA FLASH Temperatura di funzionamento certificata i 10 C 40 C Umidit relativa media di funzionamento ccccccccccccnononononononononononononononnnnnnonnnonnnonnnnnnnnnnnnnnn nn EEEE 7596 Temperatura di SIOCCAG IO RR di 20 C 60 C Grado di protezione dell involucro IP40 IK06 accom O 460 g Dimensioni asque 160 x 130 x 23 5 ATTENZIONE 1 Informazioni dettagliate e complete sono contenute nei manuali installazione programmazione e utente presenti su
8. ay cause the bracket to curve making it difficult to assemble the keypad onto the bracket itself e Forthe anti removal use two plugs supplied at the holes C and fix also block D e Connect the cable to the terminal board E e Insert the cable that comes out of the keypad into the dedicated connector F Place the cable so that it fits into the specially designed space at the bottom of the keypad this prevents it from being crimped when assembling the keypad to the bracket e Insert the keypad block in the bracket and slide it downwards e Secure with locking screws Fig 3 DS1067 058 5 ba Description detail BUS Expansion input supply via bus Holes for fixing on the box of 60 B Holes for fixing on a 3 seated box D Plastic insertion for anti dropping protection D PUS Transmission data receipt Connection terminal board 805 Keypad input supply via bus Keypad connector Closing screw O S Hole for cable transt 000 Bus For EN50131 Degree 3 classification always use the anchor bolt in position C even if the keypad is fixed to a flush mounting box This requirement is not mandatory for Degree 2 or lower installations AUDIO BUS CONNECTION For audio bus connection use twisted duplex cable If more Keypads are connected to telephony bus a cascade connection has to be used Audio bus overall length must not exceed 300 metr
9. es CONTROL PANEL KEYPAD 1067 012A speech synthesis 1067 026 BUS POWER SUPPLY AND DATA KEYPAD ACQUIRING To use the 1067 026 touch keypad after its ignition push the T4 key on the front side see Fig 4 If the parameters of the keypad must be cancelled Reset proceed as follows e open the tamper contact remove the keypad from the related bracket e push the T4 key for about 5 seconds For further information about acquiring procedure refer to the system installation manual 6 DS1067 058 INPUT CONNECTION Connect any devices to auxiliary input IN1 The Input is referred to ground and can be programmed as NC NO Balanced and Double balanced The Input can manage fast signals from seismic detectors or rolling shutters in such case it should be connect as NC type To implement connections with balancing use provided 2 7 kohm resistances with 196 tolerance NC connected NO connected to negative to negative SINGLE BALACING INPUT DOUBLE BALACING INPUT KEYPAD KEYPAD KEYPAD KEYPAD EN50131 ALL ALL ALL ALL TAMPER DETECTOR DETECTOR DETECTOR DETECTOR NG WARNING Double balance is the only EN50131 compliant connection mode Refer to the manuals of 1067 units for further more detailed information TECHNICAL CHARACTERISTICS Nominal supply voltage taken in from control panel via DUS 13 8 Vcc Operating voltage or the keypad ssa ug i eene ei orae rte IB a a Rss e aaa 1
10. l CD ROM fornito a corredo della Centrale oppure scaricandoli direttamente dal sito www urmet com 2 NON APRIRE IL CONTENITORE DELLA TASTIERA tutte le operazioni necessarie all installazione e manutenzione del prodotto non richiedono interventi all interno 3 Data la tipologia del prodotto tasti soft touch capacitivi occorre porre attenzione alla pulizia del frontale in vetro Per agevolare tale operazione presente un tasto funzione tasto T4 che provvede a bloccare le funzionalit dei tasti per un tempo prefissato di 30 secondi permettendone quindi la pulizia Tale tempo sar scandito a display 4 DS1067 058 ENGLISH GENERAL DESCRIPTION Keypad with tempered glass front side soft touch technology and OLED display This allows to control and program the 1067 series systems is equipped with a proximity key reader 1067 332 1 programmable auxiliary entries and one microphone for environment listening by phone with PSTN or GSM interface Furthermore it is provided with a vicinity sensor that allows the activation of full functionality of the device that is typically in a state of low consumption placing the hand near the area above the logo switches on the backlight the display shows the predefined information and the key reader becomes active After 30 seconds from the last action the keypad returns to standby mode Besides the usual alphanumeric and navigation keys there are 4 additional keys available whose functions when
11. ollegare il cavo alla morsettiera E e Inserire il cavetto che fuoriesce dalla tastiera sull apposito connettore F Disporre il cavo in modo tale che si collochi nell apposito spazio sul fondo della tastiera per evitare che lo stesso sia pizzicato nella fase di aggancio della tastiera alla staffa e Inserire il blocco tastiera nella staffa e farla scorrere verso il basso e Bloccare con la vite di fissaggio G Fig 3 2 DS1067 058 Fori per fissaggio su scatola da 60 Morsetto Dettaglio descrizione B Fori per fissaggio su scatola a 3 posti BUS Ingresso alimentazione espansione via bus Fori per vite protezione antiasportazione E Inserto plastico per protezione BUS Trasmissione ricezione dati antiasportazione E Morsettiera di collegamento BUS Ingresso alimentazione tastiera via bus F Connettore tastiera G Vite di chiusura A ums H Foro per passaggio cavi Per la certificazione EN50131 Grado 3 va sempre utilizzato il tassello in posizione C anche se la tastiera viene fissata su scatola da incasso non obbligatorio per il Grado 2 o inferiore COLLEGAMENTO BUS FONIA Per il collegamento del bus fonia utilizzare un doppino ritorto Se pi tastiere vengono connesse al bus fonia occorre utilizzare un collegamento a cascata La lunghezza complessiva del bus fonia non deve superare 300 metri CENTRALE TASTIERA Modulo a sintesi vocale 1067 012A 1067 026 BU