Home
        Manuale Uso e Manutenzione Serie
         Contents
1.  CV3 4LB    schedule to this certificate and the documents therein referred to     atmospheres given in Annex II to the Directive     dated September 2006   Compliance with the Essential Health and Safety Requirements has been assured    item 18 of the Schedule        protective system  These are not covered by this certificate     The marking of the equipment or protective system shall include the following       Ex  11 2 G  EEx ib IIB T1    P Browning  Certification Manag  4 October 2006          Intertek Testing  amp  Certification Limited  Intertek House  Cleeve Road  Leatherhead  Surrey  KT22 7SB  Tel    44  0 1372 370900 Fax   44  0 1372 370977    http   www uk intertek etisemko com  Registered No 3272281 Registered Office  25 Savile Row London W1X 1AA    This certificate may only be reproduced in its entirety and without any change  schedule included and is subject    to Intertek Testing and Certification Conditions for Granting Certification   Sheet 1 of 6       EC Tvoe examination certificate ITSO4ATEX23415X    36 Doc  No   BXDE S BA C001 IT R04    This equipment or protective system and any acceptable variation thereto is specified in the    Intertek Testing and Certification Limited  notified body number 0359 in accordance with Article 9 of  the Council Directive 94 9 EC of 23 March 1994  certifies that this equipment or protective system  has been found to comply with the Essential Health and Safety Requirements relating to the design  and construction of equipmen
2.  Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 1 Sicurezza  Informazioni generali       Scopo della fornitura dell analizzatore COMBIMASS   GA m    Gli strumenti COMBIMASS   GA m sono forniti con i seguenti contenuti     Strumento COMBIMASS   GA m con custodia rivestita in pelle        Kit di ricambio    Batteria ricaricabile Tubo gas per campionamento    Sono disponibili sensori di temperatura o di portata come opzione   Nel caso potranno essere inseriti nella valigetta        Sensore  opzionale  per la misura di portata  Sensore di temperatura  opzionale     BINDER Doc  No   BXDE S BA C001 IT R04 9    BINDERGROUP    Capitolo 1 Sicurezza  Informazioni generali COMBIMASS   GA m       Ricevimento dei materiali     a Disimballare con cura il sistema di misura    a Controllare che tutti gli elementi sono stati correttamente e completamente consegnati in conformit    con la bolla di consegna    a Controllare presenza di danni prima di installarlo     a Seci sono motivi di reclamo  si prega di contattare il servizio clienti     Reclami    Si prega di contattare prima il tecnico responsabile del servizio  Se non si conosce il numero di telefono del  tecnico si prega di contattare la nostra sede a Ulm   Germania  Saremo lieti di aiutarvi     Si prega di inviare lo strumento danneggiato o non correttamente fornito al seguente indirizzo     BINDER GmbH  Buchbrunnenweg 18  D 89091 Ulm   Tel     49  0 731 189 98 0  Fax    49  0 731 189 98 88    10 Do
3.  a destra del   lo schermo informa sullo stato di carica della batteria     Premere il tasto    Next     7  e lo strumento avvia la funzione  di misura del gas    Sullo schermo appariranno le ultime letture  evidenziate  nell area illuminata        Collegare il tubo del gas       AVVERTENZA       AVVERTENZA    18          Per assicurarsi che non ci siano depositi nelle celle  spurgare l ap   parecchio con aria pulita prima di analizzare il nuovo campione  di gas        Collegare il tubo flessibile di plastica al connettore    Gas In     sul   la parte superiore del COMBIMASS   GA m  Il tubo si blocchera  automaticamente nel connettore  evitando che venga spinto  fuori accidentalmente        Prestare molta attenzione nel collegare il tubo alla presa gas   evitando perdite di gas        Collegare l estremit   libera del tubo alla presa del gas o al punto  di campionamento sulla tubazione    Non dimenticare di installare il filtro esterno    Assicurarsi che la sovrapressione non superi i 30 mbar  Se  necessario  usare un controllo di pressione    Premere il tasto    Pump     3   quindi aprire la presa del gas per  farlo defluire attraverso lo strumento  Il tempo di misura    visua   lizzato sullo schermo        b BINDER    Una serie di tacche lampeggianti sul lato destro dello schermo indica che la pompa    in funzione e il gas    fluisce attraverso lo strumento     tasto  Up   4         Doc  No   BXDE S BA C001 IT R04    Attendere che la lettura si stabilizzi  quindi fermare la
4.  dall utente che    lt  The menu lign shows abbia seguito un adeguato corso di formazione  trattan       O2 Reset factory delta  dosi di gas che  anche in minima concentrazione  sono  dannosi per le persone     2  Taratura 0 0     lt  La linea del menu mostra     O2 0 0  Calibration        3  Calibrate 6 0      4  Calibrate 20 9               Gas Set point di durata     CHa 60   050  Attenzione Infiammabile    CO  40   050   Attenzione Asfissiante    O2 6  21    ppm H2S 100 ppm   1 500 ppm Attenzione Tossico  ppm NH3 1 000 ppm Attenzione Tossico       Le bombole di test gas devono essere usate con riduttore di pressione da 100 mbar         ATTENZIONE       NON collegare la bombola di test direttamente allo   y   strumento  perch   potrebbe danneggiarlo seriamen   iS e  Usare un successivo regolatore di pressione con uscita  fissa a 30 mbar              E  possibile calibrare i rispettivi punti di taratura solo  se il valore misurato rimane entro il 5  del valore de   siderato del test gas              Altrimenti il campo    calibrate    sotto il centro della  scritta non appare    Il test gas deve corrispondere alla precisione classe 1   1  di deviazione max  dal valore desiderato            24 Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 2 Funzionamento  gestione       Auto zero    La funzione    Auto zero       un opzione di taratura rapida  che azzera automaticamente tutti i canali gas   Utilizzare questa funzione in aria fresca e puli
5.  pom   pa premendo il tasto    pump     3  e mantenere la lettura   Questo riporter   in evidenza l area attorno ai valori del gas   Per visionare gli altri canali di analisi  premere il tasto     Down     8   Gli altri canali appariranno linea dopo linea   se presenti  Per tornare ai canali precedenti  premere il    BINDER    BINDERGROUP    COMBIMASS   GA m    Capitolo 2 Funzionamento  gestione       COMBIMASS   GA m con misura di HS    Le celle per H2S sono molto sensibili al sovraccarico e possono essere danneggiate irrimediabilmente anche  dopo un solo sovraccarico  Pertanto il campo di misura deve essere selezionato in base alla concentrazione  massima che ci si pu   aspettare  Comunque non va selezionato troppo ampio  poich   la precisione    legata    al valore massimo del campo     Se durante l analisi appare il simbolo     gt  gt  gt  gt  gt  gt      significa che il valore attuale    al di fuori del campo di  misura  La misura deve essre interrotta immediatamente e lo strumento ripulito con aria fresca  fino a che  le celle non indicano di nuovo 0  Se alla misura successiva  la cella HS indica valori sballati o zero o      gt  gt  gt  gt  gt       possibile che la cella sia danneggiata irrimediabilmente  A questo punto lo strumento deve  essere rimandato in fabbrica per un controllo     La tabella seguente da    una panoramica delle concentrazioni max  di ogni singolo campo di misura     Specifiche Tecniche delle celle H S nel GA m    Campo di tara   Sovraccarico ac
6.  verificare che le i pulsanti rispondano           e Prima di entrare in una zona pericolosa  verificare che possa essere azionata la pompa di campiona     mento           L analizzatore COMBIMASS   GA m non    approvato per l impiego in zona 0  secondo la categoria 1G   Vedere a pagina 7 per ulteriori dettagli su zone pericolose        BINDER Doc  No   BXDE S BA C001 IT R04 5    BINDERGROUP    Capitolo 1 Sicurezza  Informazioni generali COMBIMASS   GA m       Punti importanti per la sicurezza    ATTENZION       A  A    AVVERTENZA       e    gas campionato sar   scaricato dalla presa dello strumento  sample out  ad una velocit   di circa 500  ml min  Assicurarsi che questo gas non creer   una zona pericolosa peggiore di ZONA 1  Vedi pagina  7 per la descrizione completa delle zone pericolose        e Ripulire lo strumento con aria pulita prima del campionamento per evitare miscele di gas potenzial   mente reattivi all interno dello strumento           e Ripulire lo strumento con aria pulita dopo il campionamento fino a quando le letture del gas tossico  tornano a 0  Zero    Rimanenti gas tossici all interno dello strumento possono ridurre la durata delle celle elettrochimiche           e Utilizzare solo parti di ricambio e accessori BINDER           e Non collegare lo strumento COMBIMASS   GA m a una fonte di pressione superiore a 30 mBar sopra  la pressione atmosferica  Usare sempre un regolatore di pressione originale        e Non utilizzare il COMBIMASS   GA m a temperatur
7. 4 BINDER    BINDERGROUP    COMBIMASS   GA m    Capitolo 2 Funzionamento  gestione       Tornare all icona di start up    1  Risettare delta di fabbrica   lt  La linea del menu mostra     CH4 Reset factory delta     2  Taratura 0 0     lt  La linea del menu mostra     CH4 0 0  Calibration     3  Calibrate 60 0      4  Calibrate 50 0      1  Risettare delta di fabbrica   lt  La linea del menu mostra     CO2 Reset factory delta     2  Taratura 0 0     lt  La linea del menu mostra     CO2 0 0  Calibration        3  Calibrate 40 0         4  Calibrate 50 0         A Y    Continua nella pagina seguente    BINDER    BINDERGROUP    Procedura di taratura     La sezione seguente spiega come l utente pu   tarare i  canali dei gas non tossici CH4   CO    O   Per applicazio   ni con gas da fermentazione  si aggiungono i seguenti  punti     Punti standard di concentrazione  0   50   60 Volume            O   40   50 Volume    0 6   20 9 Volume               Questi punti di taratura possono essere adattati da Bin   der per applicazioni speciali  es  gas di discarica con bas   so CH  opp  biometano con CH  pi   elevato      Avremo il piacere di informarvi sui test gas pi   adatti per  questi casi     La precisione dell analizzatore pu   essere mantenuta  con regolare taratura dei canali gas     Quando siete nel primo menu    Reset factory delta     la  funzione    Reset       disponibile  sullo schermo sopra il  tasto  2     Per risettare lo strumento ai valori di fabbrica   premere semplicem
8. COMBIMASS       Manuale d uso e manutenzione    Analizzatore portatile COMBIMASS   GA m       BINDER    BINDERGROUP Doc  No   BXDE S BA C001 IT R04    COMBIMASS   GA m       Copyright    BINDER GmbH   Ulm 2011   Tutti i diritti riservati    Il presente manuale d uso e manutenzione    protetto da copyright    Nessuna parte di questa pubblicazione pu   essere copiata  fotocopiata  riprodotta o tra   dotta in qualsiasi forma o elaborata o distribuita elettronicamente senza il preventivo  consenso espresso per iscritto di Binder GmbH     Stampato da BINDER GmbH    IMPRESSUM       BINDER GmbH  Buchbrunnenweg 18  89081 Ulm  Germany   Tel   49  0 731 18998 0  Fax  49  0 731 18998 88    info binder flow com  www binder flow com    Manuale d uso e manutenzione    Analizzatore portatile gas COMBIMASS   GA m  portable biogas analyzer    C     0359  Ex  2G    EEx ib IIB T1  ITSO4ATEX23415X    Traduzione dal manuale originale in tedesco    Data di emissione 08 11  Si riserva il diritto di modificare il design    ry BINDER      BINDERGROUP    COMBIMASS   GA m Contenuti                      Capitolo 1 Sicurezza  Informazioni generali 5  SYMBOLS noise da A ara doe ER a eee ae 5  PRECAUZIONI DISICUREZZA    sui se eet eae ake oe Oe ERE A a de EOE REL 5  Pratica dl  SIGUFEZZA eeina sd coed Soe 4 ads boxe eee ad 5  Punti importanti perlasicurezZd veritas liada BAGG apa es ee laa e eae ee eS 6  Targhetta sul retro dell Unit      7  Comprendere gli strumenti per l utilizzo in atmosfere infiammabil
9. ENZIONE  indica possibili pericoli con un basso livello di rischio che potrebbero causare da  lievi a medie lesioni fisiche  oppure danni materiali           Il simbolo  Info  identifica informazioni importanti nel testo che viene enfatizzata        PRECAUZIONI DI SICUREZZA    Questo documento descrive le precauzioni generali di sicurezza per l utilizzo del COMBIMASS   GA m   Il presente documento    inteso come informazione aggiuntiva e non come un sostituto per le norme di    sicurezza specifiche del paese di destinazione  Il rispetto delle norme di sicurezza    responsabilit   del cli   ente  l utente e   o il personale esperto coinvolto     Prima di utilizzare l apparecchio  l utente deve leggere attentamente il presente manuale    Binder GmbH non si assume alcuna responsabilit   per il fallimento totale o parziale di rispettare le infor   mazioni contenute nel manuale  l uso non corretto da parte di personale non addestrato  la manipolazione  non autorizzata e qualsiasi utilizzo non conforme alle norme nazionali     Pratica di sicurezza    AVVERTENZA    L analizzatore COMBIMASS   GA m    stato sviluppato per l utilizzo in ambienti  dove possono essere pre     senti miscele di gas infiammabili  Quando lo si utilizza ridurre al minimo ogni processo  i movimenti e le  attivit   di ogni tipo     Considerare i seguenti punti        Prima di entrare in zona pericolosa  accendere lo strumento e verificare che il display    visibile           Prima di entrare in zona pericolosa 
10. H     Sono escluse dalla garanzia le parti di consumo   come celle elettrochimiche  batterie  filtri e custodia in pelle  La normale usura  le parti danneggiate da  cattivo uso  negligenza o incidenti sono escluse dalla garanzia     Contratto di manutenzione e servizio    Il contratto di manutenzione pu   non essere rinnovato al termine della garanzia  un apparecchio pu   es   sere controllato in fabbrica e sistemato e le parti logorate sostituite al costo preventivato    In assenza di un contratto di manutenzione  un apparecchio pu   essere controllato in fabbrica e sistemato  e le parti logorate sostituite al costo preventivato     BINDER Doc  No   BXDE S BA C001 IT R04 33    BINDERGROUP    Capitolo 3 Manutenzione  ricambi COMBIMASS   GA m       Parti di ricambio     34       Lista parti di ricambio e di usura  consigli del costruttore     1 3 misure al giorno sono considerate come base d uso del GA m   Lo strumento pu   essere utilizzato pi   spesso o in combinazione con la stazione fissa  consultare Binder         Lista dei ricambi e parti di usura per un anno di servizio     Descrizione Articolo No  Quantit    Filtro acqua esterno 3700071 20  Filtro di protezione interno 3700070 2                      Descrizione Articolo No  Quantit    Filtro acqua esterno 3700071  Filtro di protezione interno 3700070  Tubetto di analisi 3700074  Spina di connessione rapida 3700080  Batterie 3700079                            Lista dei ricambi e parti di usura per cinque anno di servizi
11. MENTE ESPLOSIVE    La commutazione o combinazione di fonti energetiche pu   formare  scintille e causare esplosione     Batterie usate o rotte sono rifiuti pericolosi  Devono portate in appro   priate strutture di riciclaggio   Adeguati contenitori si possono trovare presso i rivenditori di batterie  o punti di raccolta comunali        COMBIMASS   GA m utilizza batterie al Nickel Metal Hydride  Se ave   te bisogno di un set di batterie  abbiate cura di attenervi alle disposi   zioni locali  La vita presunta delle batterie    di circa 200 500 cicli di  carica scarica    Per cambiare le batterie  svitare le due viti sul retro dello strumento  sollevare il coperchio e sfilare le bat   terie dal loro vano    Posizionare le nuove batterie nel vano  assicurandosi dell   esatta posizione delle polarit    chiudere il coper   chio con le due viti           Posizionare le nuove batterie nel vano  assicurandosi dell esatta posizione delle polarit    chiudere il  coperchio con le due viti    Sostituire sempre le batterie in ambiente asciutto e pulito  preferibelmente al chiuso    EVITARE che polvere o umidit   possano penetrare nel vano batterie              Utilizzare SOLO batterie originali  altrimenti lo strumento pu   perdere la conformit   ATEX e causare esplo   sioni        Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 3 Manutenzione  ricambi       Sostituire il filtro del gas        ATTENZIONE       Un filtro gas    posizionato all ingresso del
12. Segnale di Batteria Scarica    Pump running indicator    _ BINDERGROUP  IMASS Lei 1      Pif Battey condition indicator       Lo stato di carica delle batterie ricaricabili    visualizzato in alto a destra  da una serie di barre orizzontali di  diversa lunghezza    3 barre indicano batteria completamente carica   2 barre carica per tre quarti   1 barra met   carica  nessun altra indicazione provvedere alla ricarica  Se nessuna barra    visualizzata  rica   ricare o sostituire la batteria     BINDER Doc  No   BXDE S BA C001 IT R04 31    BINDERGROUP    Capitolo 3 Manutenzione  ricambi COMBIMASS   GA m       Ricaricare la batteria con lo strumento spento  La spi   na dell alimentatore va semplicemente inserita nella  presa di ricarica dello strumento  fare attenzione al  punto rosso   Quando l alimentatore    collegato  la  lampadina di carica dell analizzatore diventa rossa e  circa 3 ore dopo diventa verde  segnalando la carica  completa della batteria     Se l apparecchio non viene spento prima di iniziare la  ricarica  la batteria pu   essere scaricata fino all   esau   rimento  In questo caso  rispedire l apparecchio a Bin   der per ricaricare o sostituire la batteria          e Caricare la batteria almeno una volta alla settimana  anche se l analizzatore non    stato utilizzato  Le  celle elettrochimiche interne sono alimentate 24h g  anche a strumento spento        Batterie   Akkus       AVVERTENZA    A    32       NON CARICARE O RIMUOVERE LA BATTERIA IN ZONE POTENZIAL   
13. aining electronic  components  a battery pack  a keyboard  differential pressure sensors  flow sensor or absolute pressure  sensor  toxic and oxygen sensors all housed within a plastic enclosure     External connectors are provided for charging the batteries and connection to the temperature probe  which must satisfy the requirements of Clauses 5 4 and 6 of EN 50020        The enclosure provides a Degree of Protection of at least IP20     The power for the unit is derived from a battery pack containing four rechargeable cells  Nickel Metal  Hydride  Ni MH   Varta Type VH4000 4 3A        Intrinsic safety is assured by the use of specified batteries  limitation of current  power  limitation of  capacitance and inductance  and infallible segregation     The maximum output parameters at the external connections are     Temperature Probe Battery Charging  Uo   6 4 V de Co   176 uF Um   30 V   lo   1293 mA de Lo   85 uH   Po   1 36 W   C    474 uF   L 11mH    REPORT NUMBER    Intertek Report Ref 04014519  Issue 1 dated September 2006           Intertek Testing  amp  Certification Limited  Intertek House  Cleeve Road  Leatherhead  Surrey  KT22 7SB  Tel    44  0 1372 370900 Fax   44  0 1372 370977    http   www uk intertek etisemko com  Registered No 3272281 Registered Office  25 Savile Row London W1X 1AA    This Certificate is the property of Intertek Testing and Certification Ltd  and is subject to Intertek Testing and Certification Conditions for Granting Certification   Sheet 2 o
14. ampo    Opzione per misura di flusso  pressione e temperatura    facile aggiunta di canali gas  Contatta BINDER per ulteriori dettagli    BINDER Doc  No   BXDE S BA C001 IT R04 11    BINDERGROUP    Capitolo 2 Funzionamento  gestione COMBIMASS   GA m       Caratteristiche comuni dell analizzatore Combimass   GA m    GA m2  GA m3   GA m4     Campo T    operativo   Solo 1 IR  Solo 1 IR    ATEX          O   10 000 ppm  0 10   0   100   0   100   0 25                    O   1 000 ppm       O   2 000 ppm  0   200 ppm   O   2 000 ppm  O   5 000 ppm  O   10 000 ppm    H   0 1 000 ppm                                                        NH    0   1 000 ppm      IR    Analisi con tecnologia ad IR  EC    Analisi con celle elettrochimiche       A seconda del gas  del loro campo operativo e dell applicazione  lo strumento pu   essere fornito con ap   provazione ATEX per zona 1 e 2  EEx ib IIB T1      Altri canali opzionali sonde  Tipo di sonde Campo  Temperatura O fino 100   C  Portata gas O fino 12 000  Nm  hr  Velocit   del gas 0 25 fino 25 Nm sec  Pressione   400 fino 400 mbar                           A seconda della larghezza nominale del tubo  max  400 mm     12 Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 2 Funzionamento  gestione       Consigli generali di utilizzo        e Lostrumento   utilizzato principalmente per analizzare gas umidi a vapore saturo  Se la temperatura  del gas di misurazione scende sotto il punto di rugiada  l acqua si c
15. anemometro sia abbastanza lungo per raggi   ungere il centro del tubo in cui passa il gas           Il misuratore di portata COMBIMASS   utilizza la tecnica della dispersione termica  La sonda    dotata di  due spine  una riscaldata e l altra di riferimento  non riscaldata  Usando il COMBIMASS   con gas umidi   evitare l installazione della sonda alla sommit   del tubo  posizionare la spina riscaldata sopra l altra  La di   rezione del flusso    marcata con una freccia sulla faccia piana della connessione  Ulteriori dettagli nel ma   nuale specifico del misuratore di portata    Il misuratore ha una taratura standard per tubo DN80 e una composizione del gas di CH  al 65  e di CO   al 35   Se la composizione del gas da misurare    diversa  la misura risulter   meno precisa  Usando la fun   zione  correct  dell analizzatore portatile GA m  la differenza viene compensata automaticamente           Occorre inoltre considerare che le condizioni ideali per ottenere una misura precisa sono  a monte tratto  rettilineo lungo 20 x diam  tubo e a valle tratto rettilineo lungo 10 x diam  tubo  Ulteriori dettagli nel ma   nuale specifico del misuratore di portata           Inserendo l anemometro  fare attenzione per evitare perdite di gas        Stessa attenzione nel rimuovere l anemometro  In particolare  non restare col viso vicino alla connessione     poich   il gas pu   essere espulso violentemente              Collegare l anemometro alla porta Temperatu   ra Velocit   che sitrova alla 
16. c  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 2 Funzionamento  gestione       Introduzione    II COMBIMASS   GA m    stato progettato specificamente per il monitoraggio e l analisi del contenuto di  gas da discarica  di biogas  gas da impianti di depurazione  e dei siti terreni contaminati  Esso misura il con   tenuto di metano  di ossigeno e di biossido di carbonio contenuti nel gas oltre che la velocit   del gas     Il funzionamento    estremamente semplice  ma la lettura ottenuta    estremamente precisa     Lo strumento utilizza raggi infrarossi per il metano  e l anidride carbonica e una combinazione di celle  elettrochimiche per gli altri gas  Esso contiene una  forte pompa di campionamento ad alta capacit       Possono essere collegati una variet   di sensori ester   ni  ad esempio  sensore di portata basato sul princi   pio della dispersione termica  o una sonda di  temperatura     Il sensore COMBIMASS   GA m ha una batteria rica   ricabile in    Nickel Metal Hydride    che consente una  carica di circa otto dieci ore     Un caricabatteria e un alimentatore viene fornito  con lo strumento    inoltre disponibile come opzione  una batteria di ricambio        Caratteristiche     fino a 7 canali gas     2 celle ottiche di analisi infrarosse    compensazione della pressione atmosferica     Compensazione della temperatura    Potente pompa di campionamento     Filtro interno sostituibile dall utente    Batteria ricaricabile sostituibile in c
17. cetta   tura in ppm   bile  senza danni alle  celle     Tempo max  in  condizioni anaero   biche    Tempo min  di riposo tra due campionamen  ti  sensore esposto all aria fino a Oppm di  H25        0 50 100    180 Secondi    600 Secondi  10 Minuti        O  100 200    180 Secondi    600 Secondi  10 Minuti        O   200 400    180 Secondi    1 200 Secondi  20 Minuti        0   500 1 000    180 Secondi    1 200 Secondi  20 Minuti       0   2 000 4 000    180 Secondi       0   5 000 10 000    180 Secondi    2 400 Secondi  40 Minuti          O   10 000 10 200       180 Secondi               2 400 Secondi  40 Minuti               4 800 Secondi  80 Minuti         Mantenere l analizzatore esposto all aria fino al valore di Oppm di H3S sul display     BINDER    BINDERGROUP    Doc  No   BXDE S BA C001 IT R04 19    Capitolo 2 Funzionamento  gestione COMBIMASS   GA m       COMBIMASS   GA m con misura di NH3    L elemento sensibile elettrochimico x NH3    sensibile ai gas  come HS e CO     RE Per eliminare errori di lettura  si usano 2 diversi elementi  a ca sensibili con compensazione x gas     ISe la lettura Err aumenta oltre 10   20  significa che la  nun sus uns   compensazione non    bilanciata ed    necessario un inter   vento in fabbrica        Se la lettura Err    superiore a 30   50  la misura di NH3    fuori tolleranza     Misura di portata  portatile  in opzione     INFO    INFO    A        VWERTENZA     20    Prima di tentare la misura della velocit   gas  assicurarsi che l 
18. che vorreste usare per ogni canale     BINDER Doc  No   BXDE S BA C001 IT R04 27    BINDERGROUP    Capitolo 2 Funzionamento  gestione COMBIMASS   GA m       22m a                               Settings    F Show Serial Number in search     Units Selection          Unit   Descrizione   mb Millibar    H2O Pollici di acqua  M  h Metri cubi per ora    L h Litri per ora  k W Kilowatt  BTU s    Velocita scarico dati dall apparecchio    Assicurarsi che ci sono dati nell analizzatore  Inoltre assicurarsi che l apparecchio sia collegato al PC e che  sia acceso     1  Selezionare il tasto        nel menu principale     2  Il menu download mostra lo stato dello scarico dati e si chiuder   automaticamente quando tutti i dati  sono stati caricati             va    a   e                      28 Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 2 Funzionamento  gestione       Selezionare l ID di cui volete scaricare i dati e premere    Search            up Abe 3    instrument iO  Seed  Ha  CO 3S  isc pori TE nicer a lr a ara  500 i 14780 O 202 0 1 0     OF RS 2       7605  641500 0001 10476 0 0 22 OFF       Chiudendo la finestra  vedrete tutti i dati del punto di misura di cui avete selezionato l ID     Ripetere la procedura e selezionare un altro punto di misura    risultati di quest altro punto di misura ap   pariranno sullo schermo     Marcare il diverso numero di ID  tenendo contemporaneamente premuto il tasto  lt CRTL gt   Tutti i dati dell ID  marcato 
19. di  da bombola di gas di riferimento  inserire quantit   definita di test gas fino ad un flusso di gas di  500ml min  Ad ogni singolo canale dell analizzatore COMBIMASS   GA m viene quindi assegnata una per   centuale di test gas    Binder raccomanda di usare test gas di precisione in classe 1  es  la sua composizione non deve superare    di 1  quella considerata  Pi   accurato    il test gas e pi   precisa sara la taratura dell analizzatore        La taratura dei COMBIMASS   GA m coinvolge l uso di bombole di test gas pressurizzate  Questo pu   pro   durre situazioni di pericolo come    Perdite di gas ad alta pressione   Rilascio di miscele di gas infiammabili   Rilascio di miscele di gas tossici   Attenersi sempre alle istruzioni di sicurezza del fornitore delle bombole di test gas e usare riduttori di pres   sione originali  Binder pu   mettere a disposizione dei controlli di pressione  che assicurano una pressione  di uscita 30mbar oltre la pressione atmosferica  Questo non sostituisce comunque il riduttore di pressione        Menu di taratura     22        b BINDER    e mL   ein  i 55 Lamm i   ei  Potenza  9    rosette 1000F     Light alco Zero calibrate    Accendere lo strumento  9   Appare l icona di  Start up     O O O La relativa funzione varia sui tasti  1  a  3    1 2 3       La funzione    indicata sul display sopra il tasto relativo   Premere il tasto    Calibrate     3      Siete quindi nel menu di taratura del primo canale gas     Doc  No   BXDE S BA C001 IT R0
20. e ambiente al di fuori dell intervallo di  5 a  40 C  oppure in un ambiente corrosivo           e Non aprire mai l analizzatore  Contiene parti che l utente non deve sostituire  Si rischia di perdere  la garanzia  lo strumento perde l approvazione EX           e Non utilizzare l apparecchio se    danneggiato  Es   pannello frontale allentato  viti mancanti ecc            e Non collegare o rimuovere in zona pericolosa le spine dalla presa del carica batteria   Ricaricare le batterie in zona sicura e ben ventilata utilizzando il carica batterie in dotazione        L analizzatore standard GA m5 mix misura la concentrazione di CH4  metano   O   ossigeno   CO   anidri   de carbonica  e HS  acido solfidrico  in campo    E  possibile misurare in opzione anche NH3  ammoniaca  and H   idrogeno     Con un sensore di portata opzionale     possibile misurare la portata del biogas  del gas digesto e gas da  discarica fino a 12000 Nm3 h    Con un sensore di temperatura opzionale     possibile misurare la temperatura del gas fino a 100  C  Vedere  anche tabella a pagina 8     II COMBIMASS   GA m non    infallibile  Come l utilizzo dello strumento    al di fuori del controllo di BIN     DER  BINDER non si assume alcuna responsabilit   per perdite o danni dovuti al suo utilizzo  Assicurarsi che  lo strumento    adatto all applicazione  In caso di dubbio circa l idoneit   dello strumento COMBIMASS    GA m per una particolare applicazione chiama BINDER           Si prega di notare   Le misure d
21. el caso di un apparecchio  nuovo     settato solo ID 0  Premere il tasto    down     8  per attivare la  funzione    Add ID     Il menu    Add ID    si apre premendo il tasto OK     Il punto di prelievo pu   essere aggiunto usando i tasti    plus ID    e mi   nus    ID        Il nuovo punto di prelievo    adesso aggiunto nell apparecchio col ta   sto    create     La catena di valori misurati viene quindi memorizzata  sotto il nuovo ID col tasto    store     La restante capacit   di memoria vie   ne mostrata Brevemente sul display    Il monitor ritorna al normale menu di misura        BINDER Doc  No   BXDE S BA C001 IT R04 25    BINDERGROUP    Capitolo 2 Funzionamento  gestione COMBIMASS   GA m       ae L orologio dello strumento di misura pu   essere Inserito nel menu di  LHF Go memoria  che pu   essere cancellata completamente  Solo una tara    a tura corretta dell orologio consente ai valori memorizzati di essere  letti  con un corretto ritardo     Se le misure sono rilevate da un solo punto  possono essere memo   rizzate premendo il tasto OK nel menu    store           Trasferimento dei dati in memoria al PC    Per trasferire i dati     necessario il cavo seriale  accessorio in opzione per l analizzatore portatile    dati pos   sono essere letti e gestiti facilmente per mezzo del software    SiteMan     Installare    Siteman    iniziando il  file di setup     E  comunque possibile  occasionalmente  leggere i dati col programma WINDOWS    Hyper Terminal    stan   dard ed e
22. ente il tasto    reset     La domanda     Reset factory delta     appare sul display  Premendo     OK     1  a sinistra in alto  la taratura dell utente    riset   tata a quella di fabbrica  Questo risettaggio ai valori di  fabbrica deve essere fatto prima di ogni calibrazione   che modifica i punti di taratura     Col tasto    Down     8  accedere al menu taratura      0 0      La funzione    Calibration       disponibile  sopra il  tasto  2  sullo schermo   Premere il tasto    Calibration      Questo serve per tarare il punto di zero in aria pulita   senza gas analizzati     Per selezionare il campo di misura appropriato  selezio   nare l opzione corrispondente usando il tasto    Down            Calibrate XX X    Quando la bombola di test gas     collegata  premere il tasto    Calibrate       Usando il tasto    Calibrate     il valore di set    rilevato  come nuovo valore attuale    La bombola di test gas contiene una miscela di gas da  analisi corrispondente alla tabella a pag  24  osservare le  note di sicurezza dopo la tabella  cos   come i possibili pe   ricoli a pag  22      Ripetere la stessa procedura per il secondo canale gas  del CO       Doc  No   BXDE S BA C001 IT R04 23    Capitolo 2 Funzionamento  gestione COMBIMASS   GA m       Menu di taratura     continua Ripetere la stessa procedura per il terzo canale gas del  CO     A YT A       Altri componenti del gas come H2S  H2  CO  e NH3  pos    1  Risettare delta di fabbrica sono essere tarati da personale Binder o
23. escritte nel presente manuale possono essere eseguite solo da personale  qualificato   Personale qualificato  si riferisce al personale che  a causa della loro for   mazione specialistica ed esperienza nonch   alla loro conoscenza delle norme     in grado  di identificare e valutare i rischi potenziali        Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 1 Sicurezza  Informazioni generali       Targhetta sul retro dell unita     Prodotto da  numero di serie        BINDER COMBIMASS GA m    49  0 731 18998 0 www binder flow com    Anschl  sse    Gas Ein          Gas Aus  Temperatur   Flow Eingang    Batterieladebuchse      DIE BATTERIEN LADEN  NIEMALS  DIE BATTERIEN ENTNEHMEN    DIESEN DECKEL ENTFERNEN    In potentiell explosiver Atmosph  re    Beachten Sie die weiteren Anweisungen im Benutzerhandbuch             4  Gas Data Ltd  Coventry  UK  44  0 24 7630 3311         Comprendere gli strumenti per l utilizzo in atmosfere infiammabili    Aree pericolose classificate per zone  Ci sono tre zone definite per guidare gli utenti per le necessarie precauzioni da prendere quando si lavora  in atmosfere potenzialmente infiammabili     a Zona 0   Area in cui una miscela esplosiva di gas aria    continuamente presente  o per lunghi periodi    gt  1000 h a   Sono autorizzati Solo i dispositivi di categoria 1G    a Zona 1  Area in cui    probabile che si formi una miscela esplosiva di gas aria durante le normali attivit      gt  10    lt 1000 h a   Son
24. f 6          EC Tvoe examination certificate ITSO4ATEX23415X Issue 1 June 2006    BINDER Doc  No   BXDE S BA C001 IT R04 37    BINDERGROUP    Capitolo 4 Appendice COM BIMASS   GA m       38 Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    
25. i             o oo ooooooooooooo ooo    7  Scopo della fornitura dell analizzatore COMBIMASS   GA M o    9  Ricevimento  dell materiali    accio ie ala oe SEERA PA E O a a ee ead 10  Reclamis  socia aaa o ae e rata 10  Capitolo 2  Funzionamento  gestione 11  INTFOGUZIONE iii dad e e ld a i n 11  Caratteristiche  pira rigore a e LEI A OR aaa 11  Caratteristiche comuni dell analizzatore Combimass   GA M LL 12  Consigli generalidirutiizzo  ooer eb i beg bidet ea a 13  Consigli utili per usare il tuo nuovo analizzatore COMBIMASS      00000 eee 13  Allarme  batteria bassa  sian A wae wd ee Bae ee 14  Operazione osi Vian 14  Funzionamento sicuro dell analizzatore COMBIMASS   GA M   LL 14  Controllo pannello frontale   0    15  CONNESSIONI irreale a 15  Sonda di temperatura  Opzione     16  Schermata  diriepllo Go  iosa ero leda dea 16  Spegnimento automatic o    16  Navigando tra le schermate dello Strumento    17  Analisi portatile del GAS    18  Collegare il tubordel Gas ii  ee i a 18  COMBIMASS   GA m con misura di H2S LL  19  Specifiche Tecniche delle celle H2S nel GA M 0 000 19  COMBIMASS   GA m con misura di NH3   LL 20   Misura di portata  portatile  in opzione  LL    20  Calibration procedure o    22  POCO Uli aa ee a ae fe i Be 22  Menu di tarata  a a AI iu 22  Procedura Ci tahaturas saio recipe ii 23  A heats E O E E a a a a a a A a a a 25  Guida rapida per memorizzare dati sul portatile tipo Ga M LL 25  Lettura dati via cavo e software Siteman   LL  25  Memorizzare i dat
26. i nell analizzatore 0 00 25  Trasferimento dei dati in memoria al PC    26  Istruzioni operative sintetiche di Siteman LL 26  INMTOGUZIONE   in RR 26  Principali  paragrafi del Menu scsi pa bid ne dd ed 27   AVVIO rapido Li    27  Velocit   scarico dati dall apparecchio   0 00 28  Esportare att    i RR E ina 29  Capitolo 3  Manutenzione  ricambi 31  Manutenzione ricami  cita sei watts a Le ae Ra 31  H BINDER Doc  No   BXDE S BA C001 IT R04 3    BINDERGROUP    Contenuti COMBIMASS   GA m             Istruzioni perla pulida      ora errr eke E ee ee SEE oe ee 31  Sonde di portata o    31   Cavo  barra di estensione  custodia  0 31   Segnale di Batteria Scarica    31  Batterie  AKKUS  ia la e Hae Gk a rea 32  Sostituire il filtro  dell Gass sis jected e ET a 33  GAlanizi   icons dd E LL ALL lei e ei 33  CONAIZIONI CO ESCIUSIONI prin Aa 33  Contratto di manutenzione e Servizio L00000 33  Partanna Mblos   ea ah dt ea ein 34  Capitolo 4  Appendice 35  Specifiche tecniche COMBIMASS   GA M LL 35  EC Certificato del tipo  di Esame    paci iaia ee caw ea a ee AGE SA i EE 36  4 Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 1 Sicurezza  Informazioni generali       SYMBOLS       ATTENZION    AVVERTENZA    INFO    Questo manuale mette in evidenza informazioni sulla sicurezza come segue        La nota  AWERTENZA  identifica i possibili pericoli con un livello medio di rischio che possono provocare  la morte o gravi lesioni personali           La nota  ATT
27. ical Accuracy   Typical Response Time  Tap    Gas channel campo  related to full scale FS    Typical measuring time  H S 0   200   2 000 ppm 1  O 10  di FS 60 sec  2 0   5 000   10 000 ppm 13     100   di FS 120 sec    30 sec    O   H2 O   1 000 ppm 3   di FS 90 sec  1    10  di FS 90 sec  Nhi Se MON ppn 3    100  di FS 180 sec  CO _ di di 30 sec  0   1 000 2 000 ppm  3   di FS E  1 at delivery  respectively after re calibration  Altri canali opzionali sonde  Tipo di sonda Campo Typical Accuracy Risoluzione  Temperatura O a 100   C 0 5   C 0 1   C  Portata gas O a 12 000  Nm  hr 2   della lettura 0 1 Nm  hr  Velocit   gas 0 25 a 25 Nm sec 2   della lettura 0 01 Nm sec  Pressione   400 a 400 mbar 2  di FS 1 mbar               Dipende dalla larghezza nominale del tubo  max  400 mm     Accessori standard          carica batteria  valigetta  tubetto di campionamento  manuale  cert  di taratura  Opzioni  caricatore auto  sonda di temperatura  misuratore di portata  misura di pressione             BINDER    BINDERGROUP    Doc  No   BXDE S BA C001 IT R04    35       Capitolo 4 Appendice    COMBIMASS   GA m       EC Certificato del tipo di Esame    Industrial    Intertek    EC TYPE EXAMINATION CERTIFICATE    Equipment or Protective System Intended for use in Potentially _  Explosive Atmospheres Directive 94 9 EC       EC Type Examination Certificate Number  ITSO4ATEX23415X       Equipment or Protective System  GAS DATA GFM Series    Manufacturer  GAS DATALIMITED    Address  Coventry 
28. ilogo e ab   bassa i valori per le funzioni di ingresso     9  Alimentazione ON   OFF   Questo tasto accende o spegne lo strumento    Connessioni    Porta d ingresso sonda di temperatura   velocit      Gas out       Gas in Attacco carica batterie    BINDER Doc  No   BXDE S BA C001 IT R04 15    BINDERGROUP    Capitolo 2 Funzionamento  gestione COMBIMASS   GA m       Sonda di temperatura  opzione         AVVERTENZA    AVVERTENZA          Fare molta attenzione quando si inserisce la sonda di temperatura per evitare perdite di gas           Fare molta attenzione durante la rimozione della sonda di anemometro  In particolare  evitare di stare vi   cino con il viso perch   il gas pu   essere espulso a grande forza        Collegare la sonda di temperatura alla porta temperatura velocit   posta sulla parte superiore della cassa  dello strumento    Individuare un connettore adatto e inserire la sonda di temperatura  Quando la sonda    abbastanza lon   tano senza aprire il rubinetto  aprire il rubinetto del gas  Infine  spingere la sonda quanto basta per assi   curarsi che la punta si trova al centro del tubo del gas    Ora premete il tasto  start sample   3   Lo strumento ora inizier   a misurare la temperatura all interno della  tubazione Quando la lettura si    stabilizzata  premere il tasto  stop sample   3  per mantenere la lettura   Questo riporter   l area evidenziata intorno al dato della temperatura  Rimuovere la sonda di temperatura  dal tubo    Se si desidera utilizzare le i
29. inee 3 4 carico  1 linea mezza carica  senza linee 1 4 carica o meno       NON CARICARE NE  RIMUOVERE LE BATTERIE IN ATMOSFERA POTENZIALMENTE ESPLOSIVA   La commutazione o combinazione di fonti di energia porta alla formazione di scintille  che possono innes   care esplosioni        Vedi pagina 31 nel capitolo  Manutenzione  per la sostituzione o la ricarica delle batterie    Batterie usate o rotte sono rifiuti pericolosi  Essi devono essere smaltiti presso l impianto di riciclaggio      possibile trovare cassonetti di raccolta presso i rivenditori della batteria e nei punti di raccolta differen   ziata comunale        Operazione    II COMBIMASS   GA m    stato appositamente progettato per fornire agli utenti un robusto  semplice  ma  estremamente preciso ed efficiente strumento di misura      testi sono semplici e appaiono sul display con lettere maiuscole  Utilizzando i tasti freccia  l utente pu    passare attraverso i menu    Un sistema di misura della temperatura e della portata gas pu   estendere il campo di applicazione dell ana   lizzatore    Lo spegnimento automatico dello strumento 15 minuti dopo l ultima misura consente di risparmiare la  batteria    Il LEL  in tedesco  UEG   Limite minimo di esplosione  visualizzato sullo schermo    un valore calcolato sulla  base delle concentrazioni di ossigeno e metano  Il risultato non    certificato ed    quindi solo un indicatore   Binder non si assume alcuna responsabilit    se il valore LEL viene usato come allarme     Fun
30. ita col tasto  OK     La correzione non tiene  conto automaticamente di diversi profili di flusso dovuti a diversi diametri e configurazioni del tubo   Eventuali fattori di correzione per casi particolari sono disponibili presso Binder        Pressione e temperatura del gas vengono compensate automaticamente dal misuratore   di portata COMBIMASS    Se il gas    saturo di umidit    quando la misura viene fatta a valle del fermenta   tore  e la temperature del gas    nota  la proporzione di vapore acqueo pu   essere determinata usando la  tabella seguente     Il diagramma mostra questa situazione   600 100    500 83 7    400 66 9  300    50 1    200 33 5    contenuto di acqua in      100 16 7    contenuto di acqua in grammi  metro cubo       0 20 40 60 80 100  temperatura in   C    La porzione pu   essere compensata usando un fattore di correzione  inserendolo a mano nel misuratore  di portata  Con questa correzione  l analizzatore mostrer   direttamente la portata gas secco alle condizioni  standard  riferita all attuale composizione         Osservare attentamente le istruzioni del manuale di installazione e chiudere la valvola solo quando il sen   sore    stato estratto completamente  posizione di arresto           BINDER Doc  No   BXDE S BA C001 IT R04 21    BINDERGROUP    Capitolo 2 Funzionamento  gestione COMBIMASS   GA m       Calibration procedure    Procedura    AVVERTENZA    Per prima cosa  alimentare con aria pulita e portare set di taratura a 0  per ogni test    Quin
31. lla scintilla e   o la temperatura dei componenti tale che non  possano incendiare i gas previsto entro la zona pericolosa     Ci sono due categorie di strumenti di tipo a sicurezza intrinseca     a   la    circuiti di sicurezza utilizzati impediscono la generazione di una scintilla o la temperatura in grado  di accendere il gas  anche se lo strumento sviluppa DUE difetti     a  ib    circuiti di sicurezza utilizzati impediscono la generazione di una scintilla o la temperatura in grado  di accendere il gas  anche se lo strumento si sviluppa UN difetto        IL COMBIMASS GA M    PROGETTATO PER SODDISFARE   REQUISITI DELLA CATEGORIA    ib           Testando i componenti in condizioni di guasto  come richiesto da  ib      determinata la temperatura peg   giore dei casi all interno dello strumento  Questo    usato per dare allo strumento una classificazione di  temperatura  Una guida alla classificazione temperatura    riportata qui sotto     Classe di temperatura Temperatura massima    C   T1 450  T2 300  T3 200                T4 135  T5 100  T6 85                Maggiore    la Classe T minore    la temperatura   Differenti gas saranno infiammabili a differenti temperature  Alcuni esempi sono riportati di seguito                                Gas MINIMA Classe T richiesta  Acetilene T2  300   C   Idrogeno T1  450  C    Etilene TZ  300  C   Monossido di carbonio T1  450  C   Idrogeno solforato T3  200   C   Ammoniaca T1  450   C   Propano T1  450   C   Metano T1  450   C       
32. lo strumento  Controllare il filtro ogni settimana e sostituirlo se  sporco o intasato  Utilizzare sempre filtri raccomandati  che possono essere forniti da BINDER  L uso di filtri  non raccomandati causa la perdita della garanzia     Per sostituire il filtro  rimuovere le quattro  viti alla base della porta    Sample In     Sol   levare il coperchio e rimuovere il filtro     Inserire un nuovo filtro  assicuarsi che sia  posizionato correttamente  riposizionare  il coperchio e riavvitare le viti        Garanzia    La garanzia ha una validit   di 12 mesi dalla data di spedizione e assicura che lo strumento    esente da difet   ti di materiali e di lavorazione  Durante questo periodo  BINDER riparer   o sostituir    a sua discrezione  le  parti difettose  La definizione di un contratto di manutenzione per il periodo di garanzia    obbligatorio   altrimenti non pu   essere assicurata la precisione delle misure     Se non diversamente specificato per iscritto  si intendono applicate le Condizioni e i Termini di Vendita di  BINDER     Spese di trasporto da e a sede BINDER o a centrom di servizio autorizzato sono a carico dell utente     Condizioni ed Esclusioni    Per mantenere la garanzia  il cliente deve effetture manutenzione e taratura  seguendo le istruzioni del  manuale d uso    Il contratto di manutenzione comprende la sostituzione o riparazione di parti difettose  cos   come la ma   nutenzione e la taratura  qualora necessaria  in accordo alle raccomandazioni di BINDER Gmb
33. namen   to   Premere il tasto    Start pump      3  per disattivare il campiona   mento   Premere tasto    SU     4  o     GIU      5  per scorrere tutti i  valori dei gas campionati  Premere il tasto  Next   7  per  passare al Gruppo Canale 2  Collegare l anemometro COM     Precedente     5     Next  7    4 Successivo       La misurazione della portata    attiva  dopo l attivazio   ne della pompa   Anche quando la pompa    stata spenta  la misura di  portata rimane attiva e utilizza per le correzioni l ulti              SY    Doun  8  Gi         Next  7  ma analisi gas   Successivo  Premere il tasto   Next   7  per passare alla schermata  di riepilogo   Up  4  Su  AN Next  7  Usare tasto    Up     4  e    sn Successivo    Down     8  per acce   CHA og OZ a dere alla restante area    ED LEL  di schermata  Premere  SE e tasto    Next     7  per  Precedente FU Lal p   5  536 3 HIA 27 88 Hines accedere al men   ana     lisi gas      valori misurati posso   no essere memorizzati  in questa finestra     ta   sto    store     1     Dettagli per la memorizzazione delle misure  si trovano al capitolo  Memorizzazione delle misure nell ana     lizzatore   a pag  25     BINDER    BINDERGROUP    Doc  No   BXDE S BA C001 IT R04 17    Capitolo 2 Funzionamento  gestione    COMBIMASS   GA m       Analisi portatile del gas    Dopo aver acceso lo strumento  il display mostrera prima  l icona di avvio   data di ricalibrazione e numero di serie   L indicatore di condizione della batteria in alto
34. nformazioni della temperatura per correggere l umidit    vedere ulteriori dettagli  al prossimo capitolo  misurazione portatile della velocit   del gas          Tasti 1  2 e 3 sono i tasti che possono avere diverse funzioni  come indicato sullo schermo LCD        Schermata di riepilogo    Premere il pulsante    NEXT     7  freccia destra  Questo aprir    una nuova schermata che presenta una sintesi di tutte le let   ture effettuate  Utilizzare il tasto  UP   4  e  DOWN    8   per scorrere tutti i canali disponibili    Infine premere di nuovo il tasto  NEXT   7  per tornare alla  schermata di apertura        Spegnimento automatico    16    Per conservare la durata della batteria  l analizzatore COMBIMASS   GA m dispone di un impianto di speg   nimento automatico  Lo strumento si spegne dopo 15 minuti se non vengono premuti altri tasti    Lo strumento si spegne anche se la tensione della batteria    troppo bassa per operare    In questo caso  ricaricare le batterie o montare una batteria nuova   vedere la sezione Manutenzione     Doc  No   BXDE S BA C001 IT RO4 BINDER    BINDERGROUP    COMBIMASS   GA m    Capitolo 2 Funzionamento  gestione       Navigando tra le schermate dello strumento     La carica della batteria e gli indicatori di attivita della pompa in alto a destra dello schermo      gt     Next  7     Accensione  9    Premere il tasto  Next   7  o premere un tasto qualsi   asi per il gruppo di canali 1       Premere il tasto    Start pump      3  per attivare il campio
35. o     Descrizione Articolo No  Quantit    Filtro acqua esterno 3700071  Filtro di protezione interno 3700070  Tubetto di analisi 3700074  Spina di connessione rapida 3700080  Batterie 3700079                               Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m    Capitolo 4 Appendice       Specifiche tecniche COMBIMASS   GA m             Generale       Classe Ex     ITS04 ATEX 23415  EEx ib IIB T1       Temp  Ambiente     5 a  40   C       Qualit   del gas     5 a  40  C  umidit   relativa 10 90        Vita della batteria    Carica tipica 10 ore       Tempo di carica batterie    da2a4ore       Tasso di aspirazione    400 ml min       Capacit   di memoria tipica     gt 2000 letture  gruppo di dati        Classe di protezione    IP54                                     Dimensioni 200 x 100 x 60 mm  appr    Peso 750g tipico  dipende dalle opzioni installate  Canali standard del COMBIMASS   GA m per applicazioni Biogas  iui ee Tempo di risposta tipico  Tap   Canale gas Campo Precisione tipica   Tempo di risposta tipico   0 2 Vol       5Vol    50 sec   Metano  CH4  0 a 100 Vol    1Vol      50 Vol    120 sec  2 Vol      100 Vol      0 1 Vol      10 Vol    40 sec   Anidride carbonica  CO  0 a 100 Vol    1Vol      50 Vol    120 sec  2 Vol    100 Vol      1 40 sec    9  0  Ossigeno  0   0 a 25 Vol    0 5 Vol    120 sec           D alla spedizione  dopo la ri taratura       Canali gas opzionali  max  5                                               Typ
36. o autorizzati Solo i dispositivi di categoria 1G e 2G    a Zona 2   Area in cui Area in cui non    probabile che si formi una miscela esplosiva di gas aria durante  le normali attivit   o qualora si verifichi esister   solo per un breve periodo di tempo   lt 10 h a   Sono au   torizzati solo i dispositivi di categoria 1G  2G 3G        LO STRUMENTO COMBIMASS GA M PUO  ESSERE UTILIZZATO IN ZONA 1 e ZONA 2  APPROVATO SE   CONDO CATEGORIA 2G e 3G        INFO    Diversi gas sono raggruppati secondo la facilit   con cui vengono innescati   Alcuni esempi sono riportati di seguito   Per altri gas si prega di contattare BINDER      Gas Innesco relativo  Idrogeno Acetilene Innesco pi   facile          Etilene  Monossido di carbonio       Idrogeno solforato       Ammoniaca       Propano       Vapori di benzina       Metano Innesco meno facile             BINDER Doc  No   BXDE S BA C001 IT R04 7    BINDERGROUP    Capitolo 1 Sicurezza  Informazioni generali COMBIMASS   GA m       INFO         INFO       IL COMBIMASS GA M E  ADATTO ALL USO IN ATMOSFERA INFIAMMABILE CAUSATI DALLA PRESENZA DI  GAS IN GRUPPO I  GRUPPO IIA e IIB        Progettazione e costruzione di strumenti a sicurezza intrinseca per uso in atmosfere infiamma   bili    La tecnica a sicurezza intrinseca e la costruzione    definita nella norma europea EN50020  1995    La tecnica identifica le potenziali fonti di ignizione  dai motori o da calore  e specifica la progettazione di  circuiti di sicurezza che limitano l energia de
37. ondensa fuori  Causa componenti  aggressivi presenti nel gas  come H2S e NH3 all interno dell analizzatore si pu   formare un fluido ag   gressivo che deve essere rimosso in quanto pu   recare notevoli danni se lasciato nell analizzatore In   oltre  i componenti  drenati   se presenti  possono falsificare i risultati        e Peraltro il vapore pu   peggiorare la sensibilit   quando si esegue l analisi IR  Pertanto     particolarmen   te importante evitare di sovraccaricare l analizzatore  Il filtro esterno deve essere controllato regolar   mente e nel caso sostituito  oppure dovr   essere utilizzato un separatore a coalescenza con un  collettore di condensa          e Si prega di conservare lo strumento a temperatura ambiente quando non viene usato  es   non las   ciarlo di notte in auto al freddo  ecc            e Dopo ogni misurazione    necessario ripulire le celle di riferimento con aria ambiente  dal momento  che i residui aggressivi del gas hanno un effetto negativo sulla durata delle celle elettrochimiche           e Proteggere le sonde contro forti vibrazioni       e Non piegare il cavo del connettore  rischio di rottura cavo           e Effettuare le operazioni di pulizia della sonda secondo le istruzioni di pulizia    Vedi capitolo  Manutenzione   pagina 31        Consigli utili per usare il tuo nuovo analizzatore COMBIMASS       L analizzatore GA m    stato progettato per l uso in condizioni gravose e per lunghi periodi di utilizzo senza  problemi  seguire queste 
38. raccomandazioni     e Attendere almeno 10 minuti dopo l accensione  prima di completare qualsiasi operazione di calibra   zione o di zero           e Non utilizzare la funzione  AUTO ZERO   se non dopo aver contattato Binder  poich   il punto di zero     molto stabile  Vedi pagina 25           e Sostituire regolarmente i filtri interni ed esterni  vedere sezione Manutenzione   maggiori informazioni  a pagina 33          e Prima dell uso assicurarsi che la batteria    sufficientemente carica per le misure necessarie  Caricare  lo strumento solo quando    spento e al meno una volta alla settimana  anche se non viene utilizzato        e Conservare l analizzatore solo a temperatura ambiente           e Dopo ogni misura  prima di spegnere lo strumento  ripulire le celle con aria pulita  fino a quando la  lettura dei valori del gas sono a zero  Altrimenti  i residui di gas nello strumento riducono la durata  delle celle di misura elettrochimiche        BINDER Doc  No   BXDE S BA C001 IT R04 13    BINDERGROUP    Capitolo 2 Funzionamento  gestione COMBIMASS   GA m       Allarme batteria bassa    AVVERTENZA    m   gt  gt  gt  Indicatore di  B l N D E N fun  ignamento ponpa Una serie di barre orizzontali di diversa    BINDERGROUP   DI lunghezza in alto a destra del display  COME LARS Lemm i  ein Indicatore condizione indica lo stato di carica della batteria  real CO ATL ATA LOA patteria ricaricabile        listo auto sero calibrate    3 linee indicano batteria completamente carica  2 l
39. saranno caricati e visualizzati               ni rr     Or CT     E  possibile definire anche i dati da visualizzare  nei punti in cui la ricerca dei parametri e il tempo  sono ristretti     Esportare i dati    Memorizzare i dati in un file Excel Per far questo  selezionare l opzione     Save to Excel CSV    alla voce    File      Come al solito  inserire il nome del file e la directory e premere    Store              BINDER Doc  No   BXDE S BA C001 IT R04 29    BINDERGROUP    Capitolo 2 Funzionamento  gestione COMBIMASS   GA m       30 Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 3 Manutenzione  ricambi       Manutenzione  ricambi    Istruzioni per la pulizia    Sonde di portata    A    ATTENZIONE          ATTENZIONE       Strumento e sonda devono essere spenti e o smontati per fare la pulizia           In nessun caso  le sonde devono essere completamente immerse nella soluzione        Poich   le sonde sono strumenti di misura molto sensibili  vanno puliti con molta cura   Per la pulizia si raccomanda quanto segue     e acqua corrente  e acqua saponata  e benzene puro    Cavo  barra di estensione  custodia       ATTENZIONE    Effettuare pulizia solo sulle superfici  NON immergere mai i componenti in soluzioni o acqua        e Acqua saponata   e Per depositi ostinati  benzene puro   e Pulitore in plastica EDP   e Liquido per finestre  senza ammoniaca     Queste soluzioni vanno applicate utilizzando solo sulle stracci privi di peluria     
40. seguire il    download    per trasferirlo  per es  su EXCEL      0000    CHa C0  02 H 5 NH3 LEL Vel Flow Temp Corr PipelD PumpRun date time        ppm ppm   nms 1 nm3h C  mm sec     0 0  0 7  20 2  0  0  0 0  lt  lt  lt   lt  lt   lt  lt  lt  lt   lt   lt  lt   lt   0  82 5  3 27 02 07 10 44 40      0 0  0 0  21 1  0  0  0 0  lt  lt  lt   lt  lt   lt  lt  lt  lt   lt   lt  lt   lt   0  82 5  4 27 02 07 13 26 04    Se le virgole sono sostituite da schede e i punti da virgole  la tabella dati pu   essere copiata su EXCEL     Attenzione     programma Hyper Terminal non    pi   disponibile con WINDOWS VISTA ed    una versione   pi   complicata e obsoleta  alternativa di Siteman  con parecchi svantaggi  deve quindi essere usata solo in  via eccezionale     Istruzioni operative sintetiche di Siteman    Introduzione    26    Siteman per Windows    un programma per PC  da usare con l analizzatore gas Binder    dati vengono tra   sferiti dall analizzatore al PC via interfaccia seriale RS232 alla porta COM     Usato tipicamente per     1  scaricare i dati dall analizzatore alla memoria del PC e cercare  mostrare  ordinare e stampare i dati da  PC  cos   come esportarli a file compatibile col PC     2  configurare una struttura gerarchica per la memoria dell apparecchio e ordinare i dati secondo N     codice del punto di misura in un sistema completo     3  caricare i codici e i nomi sull apparecchio     4  settare i parametri per registrazione manuale o automatica della misura di porta
41. somit   della custodia  dello strumento     Posizionate un manicotto sul tubo e inserite  l anemometro  assicurandovi che sia orientato  correttamente  La freccia dell anemometro  deve essere parallela alla tubazione  Infine  sp   ingete l anemometro nel manicotto  assicuran   dovi che l estremit   sia al centro della  tubazione    Premere il tasto    Next     7   per attivare la fun   zione velocit   del gas  Sullo schermo apparir    l ultima lettura della velocit   del gas  evidenzia   ta dalla luce attorno a questo valore     Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 2 Funzionamento  gestione       A    ATTENZIONE    Selezionare ID del tubo  usando i tasti   UP    e   DOWN    quando si illuminano  successivamente  premere OK e il primo digit lampegger    Usare i tasti   UP    e   DOWN    per modificare i valori  i tasti    LEFT     e  RIGHT    per selezionare il digit  Quando l ID del tubo    corretto  premere OK nuovamente     La misura della portata gas sar   accurata solo se compo   sizione del gas  temperatura  pressione e umidit   sono note  e compensate     La composizione del gas viene compensata    automaticamente dall analizzatore GA m COMBIMASS    A      questo punto  selezionare la voce    Correct    con i tasti iar ice    Up    e  Down    e attivare la funzione premendo lighe Cum  brevemente il tasto  OK     Quindi potete accendere e  spegnere  ON    OFF    usando i tasti Up    e  Down     La taratura attuale viene inser
42. t and protective systems intended for use in potentially explosive    The examination and test results are recorded in confidential Intertek Report Ref 04014519  Issue 1          by compliance    with EN 60079 0 2004 and EN 50020 2002 except in respect of those requirements referred to at    If the sign    X  is placed after the certificate number  it indicates that the equipment or protective  system is subject to special conditions for safe use specified in the schedule to this certificate     This EC Type examination certificate relates only to the design  examination and tests of the  specified equipment or protective system in accordance to the directive 94 9 EC   requirements of the Directive apply to the manufacturing process and supply of this equipment or    Further       BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo Apendis       MAGS Industrial    13  SCHEDULE  14  EC TYPE EXAMINATION CERTIFICATE NUMBER ITS04ATEX23415X  15  DESCRIPTION OF EQUIPMENT OR PROTECTIVE SYSTEM  Gas Data GFMxxx Series Instruments are battery powered portable multi channel gas analysers    designed to measure toxic gases  oxygen  0 21    atmospheric pressure  flow rate and temperature   and display the data  The unit also provides an audible alarm           The instrument part number GFMxxx has the xxx replaced by a 3 digit number  This number varies  depending upon the configuration of the instrument     The Gas Data GFM Series Instruments consist of up to 8 printed circuit boards cont
43. ta  trattenere il fiato  e non prima che lo strumento abbia  raggiunto la temperatura operativa        Si raccomanda di non usare questa funzione  Il punto di zero    molto stabile   La funzione    Playing around    pu   a volte falsare il punto di zero se usata in stanze con aria viziata o in  nz aNDiente inquinato        Accendere lo strumento  Appare l icona di start up  Attendere  min  15 minuti fino a quando tutti i canali gas ottenuto il funzio   namento temperatura  Premere il pulsante  auto zero   2   Inizie   r   il processo di zero automatico  Sullo schermo appare il conto  alla rovescia della pulizia dello strumento dalle tracce di gas  pri   ma di azzerare i canali gas        Guida rapida per memorizzare dati sul portatile tipo Ga m    Lettura dati via cavo e software Siteman    La misura    eseguita in accordo alle istruzioni operative a pag  20    valori misurati possono essere memo   rizzati nell apparecchio e letti pi   tardi     Memorizzare i dati nell analizzatore    Dopo la misura     possibile memorizzare i dati nell apparecchio  dai vari punti di prelievo  Per far ci    prima  assegnare un identificativo a ogni punto di prelievo  Usando la freccia     gt      7   scorrere il menu fino alla  funzione    store     che appare sullo schermo in basso a sinistra     Il sotto menu si apre premendo il tasto    store     1  in alto a sinistra  La  funzione store pu   essere eseguita solo nella finestra panoramica  Per  primo  definire l ID del punto di prelievo  N
44. ta ad ogni punto di  misura fatta col misuratore di portata Combimass    portatile o fisso        iolx    File Settings Database Instrument Help    3 2 Pl Big e 4             Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 2 Funzionamento  gestione       Principali paragrafi del menu  ay Scaricare dall apparecchio  E    Menu di ricerca    Y    Menu  Creare una nuova struttura e caricarla sull apparecchio        ict     Menu di stampa    Mh    Awvio rapido  Questa    una guida rapida per avviare il software Siteman     1  Come pratica standard  la porta seriale Com1 Se volete modificarla  selezionate  Setting  e poi  Serial  Setup  nel menu principale e cambiare la porta seriale a  2   lasciando il ritmo a 9600     2  Un progetto dovrebbe essere creato o selezionato prima che i dati vengano scaricati dall apparecchio o  cercati sul disco rigido   Per creare un progetto  prima selezionare    Manage Sites    sotto    File                                           Siteman for Window v4 10    2 PD    56 E                                           Usando Siteman per la prima volta  non troverete alcun progetto nella lista  Comunque  potete creare un  nuovo progetto in questo modo  Inserire il nome nel    Site Name    e premere il tasto    Add     Il nome inserito  apparir   immediatamente nella    Site List        3  Definizione delle unit    Selezionare    Preference    alla voce    Settings    nel menu principale  Selezionare le  unit   fisiche 
45. zionamento sicuro dell analizzatore COMBIMASS   GA m       14       Si prega di osservare le informazioni di sicurezza per un utilizzo sicuro da pagina 5 in poi   La sicurezza si ottiene con la struttura sicura dell analizzatore e con il comportamento dell utente       Doc  No   BXDE S BA C001 IT R04 BINDER    BINDERGROUP    COMBIMASS   GA m Capitolo 2 Funzionamento  gestione       Controllo pannello frontale    1   Luce  Questo tasto attiva disattiva la retroillu   minazione dello schermo        b BINDER    2   Auto Zero  Questo tasto    usato per azzerare  la calibrazione dei canali del gas ed eseguire  auto zero sui canali stessi     3   Calibrate o Start Pump   Questo tasto cambia la sua funzione in base alla  schermata visualizzata  Se    attiva la modalit     Calibrate    attivare la pompa di campiona   mento per misurare il gas o prelevare un campi   one in altro modo    4  SU   freccia in alto  Questo tasto scorre verso  l alto tutti i canali del gas e le schermate totali     5  INDIETRO   freccia sinistra  Questo tasto riporta  alla funzione precedente     6  OK  Toccando questo tasto si attivano breve   mente le funzioni di ingresso  che vengono vi   sualizzate dal lampeggiare dello sfondo  Inoltre   le funzioni sono state completate e il menu suc   cessivo selezionato        7  AVANTI   freccia destra  Questa chiave porta lo strumento al gruppo successivo di canali     8  GIU   freccia in basso  Questo tasto scorre verso il basso i canali gas e le schermate di riep
    