Home

DEC-SC - O&O S.r.l.

image

Contents

1. INVERSION DIRECTION DE ROTATION MOTEUR J1 J1 im im TJ cono COND ET See Em dec mora HU mora com 24Vac OUT 24V 4 Sortie 24Vac pour alimenter les accessoires de s curit et de commande comme les photocellules ou les r cepteurs radio SCA Signal passage pour v hicules ouvert Les quatre signalisations diff rentes indiquent l tat de l automation Clignotement lent phase d ouverture Spa COM Clignotement rapide phase de fermeture Le Feu fixe portail ouvert ou arr t en ouverture partielle Feu teint portail ferm Double flash bord sensible cras START i Entr e N O permettant de commander l automation selon la logique programm e avec les microinterrupteurs 1 2 3 4 E 8 Si la commande de start pi tonnier est maintenue activ e lorsque le portail est ferm on obtient l ouverture partielle avec un type de fonctionnement horologe La fermeture s obtient apr s de le temps de pause point sur le potentiom tre P2 avoir rel ch la commande STOP 5 5 Entree N F de s curit Son activation arr te imm diatement l automation et un start successif provoque toujours une hi rouverture Pendant le temps de pause potentiometre P2 une commande de stop amp limine la refermeture automatique en laissant le portail ouvert dans l attente de commandes 4 FOTO 2 5 Entr e N F de s curit Son activation en phase de ferm
2. Constant blinking 2 blinks followed by a W M At M pause of about 1 second a Q ia ai a oe The key T1 of the transmitter is automatically stored on the output CH1 while the key T2 on CH2 Ww Wh dh A 3 blinks followed by a pause of about 1 second a N D 4 blinks followed by a Wh Wh Wh A Ab y nN nndandnd pause of about 1 second N D 5 blinks followed by a AL Wh A W A Wh A 2 DODDDARAADO pause of about 1 second ceo N D 6 blinks followed by a pause Wh Wh Wh Wh M W M of about 1 second aaa aaa aya WARNING This operation deletes all of the radiocontrols stored on channel 1 and channel 2 from the memory of the receiver Standard Programming Press the hidden key on the transmitter until the LED remains lit then press the T key 1 2 3 or 4 on the transmitter until it starts flashing again wait for the LED to go off or switch off the power The transmitter s T key is now memorized Press the hidden key on the transmitter until the LED remains lit then press key T1 on the transmitter if other keys are pressed they are ignored until it starts flashing again wait for the LED to go off 10 s or transmit a key to exit T1 and T2 are now automatically memorized on CH1 and CH2 Advanced Programming Non associated function Non associated function Non associated function While the LED is flashing keep buttons PR
3. 3 e 4 Selezionano la risposta della logica alla sequenza di comandi di start Off Off Passo passo tipo1 apre stop chiude stop apre stop chiude Off On Passo passo tipo2 apre stop chiude apre stop chiude apre On Off Condominiale tipo1 comando di sola apertura in pausa uno start chiude ed in chiusura riapre On On Condominiale tipo2 comando di sola apertura in pausa lo start non viene considerato ed in chiusura riapre Dip 5 Off Fotocellule attive solo in chiusura in caso di oscuramento invertono la manovra Dip 5 On Fotocellule attive sia in chiusura che in apertura se le fotocellule vengono oscurate sia in fase di chiusura che di apertura l automazione si arresta fino a quando non vengono liberate per poi effettuare sempre l apertura Dip 6 Off Costa sensibile a contatto N C Dip 7 Off Prelampeggio escluso Dip 6 On Costa di sicurezza a contatto resistivo da 8 2kQ Dip 7 On Prelampeggio di 2 sec inserito Dip 8 Off Frenatura elettrica a finecorsa esclusa Dip 8 On Frenatura elettrica a finecorsa attivata 7 REGOLAZIONE DEI TRIMMER P1 COPPIA Imposta il valore di coppia utile per muovere il serramento dopo lo spunto di 1 5 sec a potenza massima Tensione regolabile da 120 230V P2 T PAUSA Imposta il tempo di pausa da 2 120 sec Il tempo di lavoro preimpostato a 90 sec di manovra utile oltre alla quale si arresta il motore Libis 8 RICEVENTE RADIO 8 1 DATI TECNICI
4. Appiyer sur PR2 pour sortie canal CH2 Programmation Standard N a Appuyer sur la touche cach e de l metteur oe jusqu ce que la led reste allum e et appuyer sur la Si au bout de 10 s aucune m morisation n est effectu e on touche T 1 2 3 ou 4 de l metteur jusqu la reprise Programmation h A 5 a quitte le mode de programmation du clignotement attendre l extinction de la Led ou couper l alimentation Maintenant la touche T de E l metteur est m moris e 2 clignotements suivis par une Wh dh A Ab Appuyer sur la touche cach e de l metteur jusqu M morisation pause d environ 1 s OCaooa que la led reste allum e puis appuyer sur la touche T1 de automatique pour l metteur la pression d autres touches est ignor e jusqu l metteur avec La touche T1 de l metteur sur la sortie CH1 et la touche T2 sur la la reprise du clignotement attendre l extinction de la Led Sortie impulsive sortie CH2 sont automatiquement m moris es 10 s ou transmettre une touche pour sortir Maintenant T1 et T2 sont automatiquement m moris s sur CH1 et CH2 AL Clignotement de fa on constante DA Programmation VOLU E 3 clignotements suivis par AL Ak A ZA At Ab une pause d environ 1 s Na A A AO Sortie pas pas Fonction non associ e N D 4 clignotements suivis par M Wh M M MO M M une pause d environ 1 s ZJABOAMAADO Fonction non associ e temporisateur 5 clignotements suiv
5. L schen des gesamten Speichers im Empfanger PR1 Ausgang Kanal CH1 A lt PR2_Ausgang Kanal CH2 d EE Beim erstmaligen Dr cken der Taste PR1 f r Kanal 1 oder PR2 f r Kanal 2 wird der Empf nger in den Programmiermodus versetzt Bei jedem nachfolgenden Dr cken der Taste PR wechselt der Empf nger zur jeweils n chsten Funktion die an der Blinkfrequenz zu erkennen ist siehe Tabelle Nach Auswahl des Kanals PR1 oder PR2 und der gew nschten Funktion legt man die Taste T T1 T2 T3 oder T4 des Senders im Speicher des Empfangsteils ab siehe hierzu die Angaben der Programmiertabelle EEE en Konstantes Blinken aca ai Falls f r eine Zeit von 10 S keine Abspeicherungen vorgenommen werden wird die Programmierung verlassen 2 Blinker gefolgt von 1 AL A dh Sekunde Pause Qana Die Sendertaste T1 wird beim Speichern automatisch dem Ausgang CH1 zugewiesen die Taste T2 dem Ausgang CH2 W W W DDA 3 Blinker gefolgt von 1 S Pause W W W aya N D 4 Blinker gefolgt von 1 W Wh Wh Wh Sekunde Pause OOOO 34 A W W Oogog N D 5 Blinker gefolgt von 1 S Pause W W W W MW Lai ADDON N D W Wh ye AAA 6 Blinker gefolgt von 1 S Pause V V M M M W A Daz2 ACHTUNG Dieser Vorgang l scht s mtliche Fernsteuerungen die auf Kanal 1 oder 2 gespeichert sind aus dem Empfangsteil Standart Programierung Dr cken Sie die versteckte Taste des Send
6. LINEA 230V Alimentazione a 230V 50Hz con protezione interna a mov e fusibile 5x20 da 6 3A 22 Collegare la fase ed il neutro come riportato in serigrafia Utilizzare un cavo tipo HO7RN F 2x1 5 T min L N E SMART 800 Collegare il conduttore giallo verde della rete di alimentazione al morsetto di terra dell apparecchio 1 LAMP Gi LAMPEGGIANTE LUCE GIALLA a 230V 40W max N INVERSIONE SENSO DI ROTAZIONE MOTORE 1 1 El im gt E coNp gt E conp EX MOTB Eq MoTB Eh moTc O gt gt gt MOTC mora mora 5 2 MORSETTIERA INGRESSI USCITE IN BASSA TENSIONE J3 COM 24V OUT 24V Uscita a 24Vac per alimentare accessori di sicurezza e comando come fotocellule o ricevitori radio SCA Spia carraio aperto Con quattro segnalazioni differenti indica lo stato dell automazione Lampeggio lento fase di apertura SCA COM z Lampeggio veloce fase di chiusura Le Luce fissa cancello aperto o anche fermo in apertura parziale Luce spenta cancello chiuso Lampeggio doppio costa di sicurezza premuta S START S 5 Ingresso N A che consente di comandare l automazione secondo la logica programmata tramite i dip 1 2 3 4 5 o Se a cancello chiuso viene mantenuto attivato il comando di start si ottiene l apertura totale con tipologia di funzionamento a orologio e quando lo si libera dopo il tempo di pausa
7. O amp O CENTRALE DI COMANDO MANUALE D INSTALLAZIONE ED USO CONTROL UNIT INSTALLATION AND OPERATION MANUAL CENTRALE DE COMMANDE MANUEL D INSTALLATION ET D UTILISATION O EN STEUERZENTRALE INSTALLATIONS UND BEDIENUNGS 8 CENTRAL DE MANDO MANUAL D INSTALACION Y USO DEC SC SINGERT CERME O amp O s r Via Europa 2 42015 Correggio R E Italy Phone 39 0522 740111 Fax 39 0522 631290 Internet www oeo it E mail oeo oeo it Societ soggetta ad attivit di direzione e coordinamento di SOMFY S A Company subject to management and coordination activities by SOMFY S A Soci t sujette des activit s de direction et de coordination de SOMFY S A Gesellschaft unter der F hrung und Koordinierung von SOMFY S A Sociedad sujeta a actividades de direcci n y coordinaci n de SOMFY S A Indice Pagina 1 INTRODUZIONE 3 2 CARATTERISTICHE PRINCIPALI 3 3 CARATTERISTICHE TECNICHE 3 4 SICUREZZA DELL INSTALLAZIONE 4 5 COLLEGAMENTI E FUNZIONALITA DI INGRESSI E USCITE 4 5 1 MORSETTIERA DI POTENZA J1 J2 4 5 2 MORSETTIERA INGRESSI USCITA IN BASSA TENSIONE 3 4 5 3 MORSETTIERA ANTENNA COSTA J4 5 6 CONFIGURAZIONE DEI DIP SWITCH 5 7 REGOLAZIONE DEI TRIMMER 5 8 RICEVENTE RADIO 6 8 1 DATI TECNICI RICEVENTE 6 8 2 FUNZIONALIT CANALE RADIO 6 8 3 INSTALLAZIONE ANTENNA 6 8 4 PROGRAMMAZIONE MANUALE 6 8 5 PROGRAMMAZIONE
8. en attendant la sortie du mode programmation 13 T4 ou en coupant l alimentation au r cepteur 9 MISE EN GARDE Il est conseill de r aliser une installation pr voyant tous les accessoires n cessaires assurer un fonctionnement conforme la l gisla tion en vigueur en utilisant toujours des dispositifs d origine O amp O L utilisation et l installation de ces appareils doit rigoureusement respecter les indications fournies par le fabricant O amp O Ce dernier est exon r de toute responsabilit en cas de d g ts provoqu s par un usage impropre ou d raisonnable O amp O srl d cline toute responsabilit en cas d erreurs ou d inexactitudes contenues dans ce mode d emploi Elle se r serve aussi le droit d apporter toutes les modifications ou elle jugera utiles tout moment et sans aucun pr avis 18 TABLEAU A Le premier appui sur la touche PR1 pour le canal 1 ou PR2 pour le canal 2 pr dispose le r cepteur en modalit programmation A chaque appui successif sur la touche PR le r cepteur passe la configuration de la fonction suivante indiqu e par le nombre de clignotements voir tableau Par cons quent apr s avoir s lectionn le canal PR1 ou PR2 et la fonction d sir e il faudra m moriser la touche T1 T2 T3 ou T4 de l metteur dans la m moire du r cepteur comme indiqu dans le tableau programmation gt 1 Appiyer sur PR1 pour sortie canal CH1
9. 5 2 lt 8 2kQ gew hlt werden M M E 6 KONFIGURATION DES DIP SWITCH Dip switch Nr 1 und 2 Anw hlen der Betriebslogik Off Off Logik Person anwesend Die Automation funktioniert bei gedr ckt gehaltenen Steuerelementen Der Startbefehl bewirkt ein ffnen und ein SchlieBen Das Gesetz verbietet funkgesteuerte Befehle bei einer Logik Person anwesend Off On Halbautomatische Logik Die Automation funktioniert mit Impulssteuerungen ohne automatisches Schlie en nach dem ffnen Daher ist es zum Steuern des Schlie vorgangs sowohl w hrend des normalen Zyklus als w hrend des Fu g nger Zyklus erforderlich auf Start oder Start Fu g nger On Off Automatische Logik Typ 1 Die Automation funktioniert mit Impulsen Im normalen Zyklus wird nach abgeschlossener ffnungsphase nach Ablauf der im Trimmer P2 eingestellten Zeit die automatische Schlie phase aktiviert Im partiellen Zyklus Fu g nger ist die Logik halbautomatisch weshalb nach Abschluss der ffnungsphase ein Impuls am Eingang Start Fu g nger erforderlich ist On On Automatische Logik Typ 2 Die Automation funktioniert mit Impulsen Im normalen Zyklus wird nach abgeschlossener ffnungsphase nach Ablauf der im Trimmer P2 eingestellten Zeit die automatische Schlie phase aktiviert Im partiellen Zyklus Fu g nger ist die Logik automatisch mit einer festen Pausenzeit von 10 Sekunden Die Steuerung START besitz P
10. 5 3 BORNERA DE BORDE DE SEGURIDAD Y ANTENA J4 29 CONFIGURACION DE LOS DIP SWITCH 29 REGULACION DE LOS TRIMMER 29 RECEPTORA RADIO 30 8 1 DATOS TECNICOS RECEPTOR 30 8 2 FUNCIONALIDADES CANAL RADIO 30 8 3 INSTALACION DE LA ANTENA 30 8 4 PROGRAMACION MANUAL 30 8 5 PROGRAMACION MODALIDAD DE AUTOAPRENDIZAJE 30 ADVERTENCIAS 30 TABLA 31 26 Instrucciones para instalaci n y uso 1 INTRODUCCION ME La central de mando DEC SC ha sido desarrollada para gestionar automatismo SMART 800 y MEGA 2000 para verjas correderas La notable cantidad de l gicas que se pueden seleccionar permite satisfacer incluso especiales condiciones operativas en las instalaciones 2 CARACTER STICAS PRINCIPALES L gica de control por microprocesador Pilotos que muestran el estado de las entradas Regletas de bornes extraibles en las entradas de baja tensi n Frenado el ctrico a final de carrera para verjas con n mero de ciclos e inercia especiales Salida para indicador de puerta abierta Radio receptor 433 MHz integrado Log B B BB 8 5 8 8 8 E H S Ed 5 1 Regleta de bornes motor condensador 2 Tablero de bornes de potencia J3 Regleta de bornes entradas salidas baja tensi n 4 Bornera borde de seguridad de antena SW1 Tecla de mando START SW2 Tecla de mando AP PED SW3 Switch P1 Trimme
11. Bremsung bei ausgeschlossenem Endschalter Dip 8 On Elektrische Bremsung bei aktiviertem Endschalter 7 TRIMMEREINSTELLUNG P1 MOMENT Stellt den Nutzmomentwert zum Bewegen des Tores beim Anlaufen von 1 5 Sek bei H chstleistung ein Spannung einstellbar von 120 bis 230V P2 T PAUSE Stellt die Pausenzeit zwischen 2 120 Sek ein Die Betriebsdauer ist auf 90 Sekunden Man vernutzzeit voreingestellt nach deren Ablauf der Motor angehalten wird 23 8 STECKFUNKEMPF NGER 8 1 TECHNISCHE DATEN EMPFANGER Max Anzahl der abspeicherbaren Funksteuerungen 64 Frequenz 433 92MHz Code mit Rolling Code Algorhythmus Anzahl Kombinationen 4 Milliarden 8 2 FUNKTION FUNKKANAL Kanal 1 sendet den Startbefehl Kanal 2 sendet den Fu g nger ffnungsbefehl AP PED 8 3 ANTENNENINSTALLATION Verwenden Sie eine auf die Frequenz von 433MHz abgestimmte Antenne Die eventuelle N Antenne an die Antennenklemme anschlie en NS Verwenden Sie ein Koaxialkabel RG58 gt No A Antennekabel RG58 Y i COSTA SHIELD ANTENNA 8 4 MANUELLE PROGRAMMIERUNG Bei Standardanlagen wo die fortgeschrittenen Funktionen nicht ben tigt werden k nnen die Sender von Hand programmiert werden Orientieren Sie sich an der Programmiertabelle A wo eine Standardprogrammi
12. Frenado el ctrico con tope recorrido excluido Dip 8 On Frenado el ctrico con tope recorrido activado 7 REGULACI N DE LOS TRIMMER P1 PAR Fija el valor de par til para mover el cierre despu s del arranque de 1 5 seg a potencia m xima Tensi n regulable de 120 230V P2 T PAUSA Fija un intervalo de tiempo de pausa de 2 120 seg El tiempo de trabajo est programado a 90 segundos de maniobra til transcurrido el cual se para el motor 29 8 RECEPTORA RADIO 8 1 DATOS TECNICOS RECEPTOR N m x radiotransmisores memorizables 64 Frecuencia 433 92MHz C digo mediante Algoritmo rolling code N combinaciones 4 mil millones 8 2 FUNCIONALIDADES CANAL RADIO Canal 1 Env a el mando de START Canal 2 Env a el mando de ab peatonal AP PED 10 3 INSTALACION DE LA ANTENA Hay que utilizar una antena sintonizada en los 433 MHZ Conectar la eventual antena afinada en la bornera antena Utilizar cable conc ntrico RG58 gt LU I amp N No a 2 COSTA SHIELD ANTENNA cable antena RG58 Y 10 4 PROGRAMACION MANUAL En el caso de instalaciones standard en las que no se requieran funciones avanzadas es posible proce der a la memorizaci n manual de los transmisores teniendo en cuenta la tabla de programaci n A y el ejemplo para la progr
13. RICEVENTE N max radiotrasmettitori memorizzabili 64 Frequenza 433 92MHz Codice a mezzo Algoritmo rolling code N combinazioni 4 miliardi 8 2 FUNZIONALIT CANALE RADIO Canale radio 1 Invia il comando di START Canale radio 2 Invia il comando di apertura pedonale AP PED 8 3 INSTALLAZIONE ANTENNA Usare una antenna accordata sui 433MHz Collegare l antenna sui morsetti antenna HHH antenna RG58 Y utilizzando un cavo coassiale RG58 le N Na COSTA SHIELD ANTENNA 8 4 PROGRAMMAZIONE MANUALE Nel caso di installazioni standard nelle quali non siano richieste le funzionalit avanzate possibile proce dere alla memorizzazione manuale dei trasmettitori facendo riferimento alla tabella di programmazione A per la programmazione base 1 Se si desidera che il trasmettitore attivi il canale 1 premere il pulsante PR1 oppure se si desidera che il trasmettitore attivi il canale 2 premere il pulsante PR2 2 AI lampeggio del led DL1 premere il tasto nascosto del trasmettitore il led DL1 rester acceso fisso 3 Premere il tasto da memorizzare del trasmettitore il led DL1 lampegger velocemente indicando l avve nuta memorizzazione In seguito riprender il lampeggio normale 4 Per memorizzare un ulteriore trasmettitore ripetere i passi 3 e 4 5 Per uscire dal modo di memorizzazione attendere fino al
14. completo spegnimento del led oppure premere il tasto di un telecomando appena memorizzato NOTA IMPORTANTE CONTRASSEGNARE IL PRIMO TRASMETTITORE MEMORIZZATO CON IL BOL LINO CHIAVE MASTER Il primo trasmettitore nel caso di programmazione manuale assegna il codice chiave al ricevitore questo codice risulta necessario per poter effettuare la successiva clonazione dei radiotrasmettitori Tasto nascosto Questo modalit serve per eseguire una copia dei tasti di un trasmettitore gi memorizzato nella ricevente senza accedere alla ricevente Il primo trasmettitore deve essere memorizzato in modo manuale vedi paragrafo 8 4 a Premere il tasto nascosto del trasmettitore gi memorizzato b Premere iltasto T del trasmettitore gi memorizzato che si desidera attribuire anche al nuovo trasmettitore c Premere entro 10s il tasto nascosto del nuovo trasmettitore da memorizzare d Premere il tasto T che si desidera attribuire al nuovo trasmettitore e Per memorizzare un altro trasmettitore ripetere dal passo 6 entro un tempo max di 10 secondi altrimenti la ricevente esce dal modo programmazione f Percopiare un altro tasto ripetere dal passo a attendendo l uscita dal modo programmazione o togliendo alimentazione alla ricevente 8 5 PROGRAMMAZIONE MODALIT AUTOAPPRENDIMENTO Tasto nascosto fa T2 9 AVVERTENZE Si raccomanda di eseguire un installazione che preveda tutti gli acc
15. memorizzazioni si esce dal modo programmazione Lampeggio in modo costante 2 lampeggi seguiti da una pausa Vv A Ad di circa 1 secondo Nono Viene automaticamente memorizzato il tasto T1 della trasmittente sull uscita CH1 ed il tasto T2 sull uscita CH2 Wh Ak 1 1 8 3 lampeggi seguiti da una pausa di circa 1 secondo N D 4 lampeggi seguiti da una pausa AL M MW di circa 1 secondo AVO faye A Wh M dle Bl e IG Im N D 5 lampeggi seguiti da una pausa W Ww Ak 12 W Se a AL M Ab di circa 1 secondo aye ya N D 6 lampeggi seguiti da una pausa M Wh Wh Ak Wh A di circa 1 secondo AA Ta ATTENZIONE Questa operazione cancella dalla memoria della ricevente tutti i radiocomandi memorizzati sia sul canale 1 sia sul canale 2 Programmazione Standard Premere il tasto nascosto della trasmittente fino a che il led resta acceso quindi premere il tasto T 1 2 3 6 4 della trasmittente fino alla ripresa del lampeggio attendere lo spegnimento del Led o trasmettere un tasto per uscire Ora il tasto T della trasmittente memorizzato Premere il tasto nascosto della trasmittente fino a che il led resta acceso quindi premere il tasto T1 della trasmittente la pressione di altri tasti viene ignorata fino alla ripresa del lampeggio attendere lo spegnimento del Led 10s o togliere alimentazione Ora T1 e T2 sono automaticame
16. 1 LEISTUNGSKLEMMENBRETT J1 J2 _ LINIE 230V A oe Eingang Linie 230V mit internem Schutz mittels MOV und Schmelzsicherung 5x20 zu 6 3 A y Den Neutralleiter und die Phase wie auf dem Siebdruck dargestellt anschliessen Ein Kabel des Typs HO7RN F 2x1 5 Erde verwenden Die gelb gr ne Leitung des Versorgungsnetzes an die Erdungsklemme des Ger tes legen 1 LAMP KEEN BLINKER GELBES LICHT zu 230V max 40W N 2 RICHTUNGSUMKEHR DES MOTORS J1 J1 El Eq c Eq coNp conp Eq more I more O E morc O gt gt gt gt HU morc mora I mora 5 2 KLEMMENBRETT NIEDERSPANNUNGS EINGANGE AUSGANGE J3 COM 24Vac OUT 24V 24 Vac Ausgang zum Speisen der Sicherheitszubeh r und Steuerteile wie Lichtschranken oder Funkempf nger SCA Kontrollleuchte offene Einfahrt Mit vier verschiedenen Anzeigen wird der Status der Automation angezeigt Langsames Blinken ffnungsphase i cw Schnelles Blinkien Schlie phase Le Festes Licht Ge ffnetes Tor oder Stillstand bei teilweiser ffnung Gel schtes Licht Geschlossenes Tor Doppelblinken Sicherheitsr cken gedr ckt START EN s NO Eingang zur Steuerung der Automation gem der mit den dip 1 2 3 4 8 Wenn bei geschlossenem Tor die Steuerung Start gedr ckt gehalten wird erfolgt eine totelle ffnen des Tors mit Uhrbe triebtypologie und wenn die Start Steuerung losge
17. 1 and PR2 on the receiver held down together for longer than 10 sec The LED flashes very quickly By the time the LED goes off all the transmitters are deleted and you exit programming mode LEGEND NUMBER OF LED DL1 BLINKING SIGNALS FUNCTION DESCRIPTION PROGRAMMING PROCEDURE 13 Sommaire Page 1 AVANT PROPOS 15 2 CARACTERISTIQUES PRINCIPALES 15 3 CARACTERISTIQUES TECHNIQUES 15 4 SECURITE DE L INSTALLATION 16 5 CONNEXIONS ET DESCRIPTION DES ENTR ES ET DES SORTIES 16 5 1 BORNIER D ALIMENTATION J1 2 16 5 2 BORNIER ENTREES SORTIES A BASSE TENSION J3 16 5 3 BORNIER D ANTENNE ET LISTEL DE SECURITE J4 17 6 CONFIGURATION DES MICROINTERRUPTEURS 17 7 REGLAGE DES POTENTIOMETRES 17 8 RECEPTEUR RADIO 18 8 1 DONNEES TECHNIQUES RECEPTEUR 18 8 2 FONCTION CANAL RADIO 18 8 3 INSTALLATION ANTENNE 18 8 4 PROGRAMMATION MANUELLE 18 8 5 PROGRAMMATION MODALITE AUTO APPRENTISSAGE 18 9 MISE EN GARDE 18 TABLEAU A 19 14 Doso DEC SC Mode d emploi 1 AVANT PROPOS ME La centrale de commande DEC SC a t d velopp e pour le contr le de automatisme SMART 800 et MEGA 2000 pour portes cou lissantes La grande disponibilit de logiques s lectionnables permet de satisfaire les conditions particuli res d exercice des installations 2 CARACTERISTIQUES PRINCIPALES Logique microprocesseur D
18. ERHEIT DER INSTALLATION Die nachstehenden Vorschriften sind aufmerksam zu lesen damit der gesetzlich vorgeschriebene Schutzgrad erhalten wird 1 Alle Anschl sse am Klemmenbrett sind unter Beachtung der in dem vorliegenden Handbuch enthaltenen Anleitungen und unter Anwendung der f r die kunstgerechte Ausf hrung von elektrischen Anlagen erforderlichen Techniken zu realisieren 2 Oberhalb der Installation ist ein mehrpoliger thermomagnetischer Schutzschalter mit einem ffnungsabstand der Kontakte von mindestens 3 mm zu installieren 3 Falls noch nicht vorhanden ist ein Differentialschalter mit Schwelle 30 mA zu installieren 4 Die Wirksamkeit der Erdungsanlage berpr fen und alle mit Erdungsklemme oder kabel ausgestatteten Teile der Automation an diese Erdungsanlage anschlie en Es ist mindestens eine externe Anzeigevorrichtung Typ Ampel oder Blinker sowie ein Gefahr oder Achtungsschild zu installieren Auf der Basis der von der jeweiligen Installationstypologie ausgehenden Gefahr alle erforderlichen Sicherheitsvorrichtungen anbringen Die Leistungskabel Querschnitt mind 1 5 mm von den Niederspannungssignalkabeln Querschnitt mind 0 5 mm trennen Die nicht verwendeten NC Eing nge berbr cken Eventuelle in Reihe zu schaltende Kontakte am gleichen NC Eingang in Reihe schalten 0 Die an den gleichen NA Eingang angeschlossenen Eing nge parallel schalten 5 ANSCHL SSE UND FUNKTION DER EIN UND AUSG NGE 5
19. MIERUNG 24 9 WICHTIGE HINWEISE 24 TABELLE A 25 20 Installations und Bedienungsanleitungen 1 EINLEITUNG ME Die Steuerzentrale DEC SC wurde zur Verwaltung der Automation SMART 800 MEGA 2000 f r Schiebetore entwickelt Die Vielzahl an einstellbaren Logiken erlaubt es auch besonderen Einsatzbedingungen an den Anlagen gerecht zu werden 2 HAUPTEIGENSCHAFTEN Mikroprozessorgesteuerte Logik Led zur Anzeige des Status der Eing nge Ausziehbare Klemmenbretter an den Niederspannungseing ngen Elektrisches Abbremsen am Endschalter f r Tore mit einer besonderen Anzahl Zyklen und Tr gheit Ausgang f r Kontrolleuchte offenstehendes Tor Integriertes Empfangsger t 433 MHz Log H B B HH B u N lt YN J1 Klemmenbrett Motor Kondensator 2 Leistungsklemmenbrett J3 Niederspannungsklemmenbrett Eing nge Ausg nge J4 Anschlussklemmenbret Sicherheitskopfflanke und Antenne SW1 Steuertaste START SW2 Steuertaste AP PED SW3 Dip Switch P1 Trimmer Drehmoment P2 Trimmer Pausenzeit F1 Leitungssicherung 6 3A F2 Niederspannungssicherung 100 mA 3 TECHNISCHE EIGENSCHAFTEN Versorgung 230Vac 10 50Hz Motorausgang 230Vac 1 5A max Blinker 230Vac 40W max SCA Ausgang 24Vac 3W max Zubeh rausgang 24Vac 3W max 22 lt 4 SICH
20. MODALIT AUTOAPPRENDIMENTO 6 9 AVVERTENZE 6 TABELLA A 7 Doso DEC SC Istruzioni per installazione ed uso 1 INTRODUZIONE ME La centrale di comando DEC SC stata sviluppata per gestire le automazioni SMART 800 e MEGA 2000 per cancelli scorrevoli La notevole disponibilit di logiche selezionabili consente di soddisfare anche particolari condizioni operative sugli impianti 2 CARATTERISTICHE PRINCIPALI Logica a microprocessore Led che visualizzano lo stato degli ingressi Morsettiere estraibili sugli ingressi in bassa tensione Frenatura elettrica a finecorsa per cancelli con particolare numero di cicli ed inerzia Uscita spia cancello aperto Ricevente radio 433MHz integrata LDA H H HR B HRH RB J1 Morsettiera motore J2 Morsettiera di potenza J3 Morsettiera ingressi uscite bassa tensione J4 Morsettiera antenna costa SW1 Tasto di comando START SW2 Tasto di comando AP PED SW3 Dip Switch P1 Trimmer coppia P2 Trimmer tempo pausa F1 Fusibile linea 6 3A F2 Fusibile bassa tensione da 100mA 3 CARATTERISTICHE TECNICHE Alimentazione 230Vac 10 50 Hz Uscita motore 230Vac 1 5A max Uscita lampeggiante 230Vac 40W max Uscita SCA 24Vac 3W max Uscita accessori 24Vac 3W max 4 SICUREZZA DELL INSTALLAZIONE Affinch si
21. amaci n base 1 Si se desea que el transmisor active la salida 1 hay que pulsar el bot n PR1 si se desea que el tran smisor active la salida 2 se tiene que pulsar el bot n PR2 2 Cuando el led DL1 empiece a parpadear hay que presionar la tecla oculta del transmisor el led DL1 permanecer encendido de manera fija 3 Pulsar la tecla para memorizar el transmisor el led DL1 parpadeara r pidamente indicando que la memorizaci n ha sido realizada Luego volver a parpadear normalmente 4 Para memorizar otro transmisor repetir los pasos 2 y 3 5 Para salir del modo de memorizaci n esperar hasta que el led se apague por completo y pulsar la tecla de un mando a distancia antes memorizado NOTA IMPORTANTE EL PRIMER TRANSMISOR MEMORIZADO DEBE MARCARSE CON EL ADHESI VO DE LA LLAVE MASTER El primer transmisor en el caso de programaci n manual asigna el c digo clave al receptor este c digo resulta necesario para poder efectuar la sucesiva clonaci n de los transmisores Tecla oculta 10 5 PROGRAMACION MODALIDAD DE AUTOAPRENDIZAJE Esta modalidad sirve para efectuar una copia de las teclas de un transmisor ya memorizado en el receptor sin acceder a ste ltimo El primer transmisor debe memorizarse de forma manual v ase el apartado 8 4 Hay que realizar lo siguiente a Presionar la tecla oculta del transmisor ya memorizado b Presionar la tecla T del transmisor ya memorizado que se desea atrib
22. ara salida canal CH1 NES PR2 para salida canal CH2 p La primera vez que se presiona la tecla PR1 para el canal 1 o PR2 para el canal 2 se configura el receptor en la modalidad programaci n Cada vez que se vuelve a presionar la tecla PR el receptor pasa a la configuraci n de la funci n d A A WM Centelleo de manera constante a de Si en el lapso 10 segundos no se realiza ninguna memorizaci n se sale del modo de programaci n 2 centelleos seguidos por una pausa de aprox 1 5 Ww La tecla 1 del transmisor se memoriza automaticamente en la salida CH1 y la tecla T2 en la salida CH2 Ak Wh dh RA 3 centelleos seguidos por una W A pausa de aprox 1 s D N D 4 centelleos seguidos por una pausa de aprox 1 5 dh Ak Ak W dh M W 111 Of N D 5 centelleos seguidos por una MW M Wh W W Wh Ab pausa de aprox 1 s aaa alla a IS N D 6 centelleos seguidos por una Wh M M M M W MV pausa de aprox 1 s Saale aa jATENCION Esta operaci n cancela de la memoria del receptor todos los radiomandos memorizados tanto en el canal 1 como en el canal 2 sucesiva que es indicada por el numero de centelleos v ase la tabla Asi pues despu s de seleccionar el canal PR1 o PR2 y la funci n deseada se proceder a la memorizaci n de la tecla T T1 T2 T3 o T4 del transmisor en la memoria del receptor como
23. arting for 1 5 sec at full power Adjustable voltage from 120 to 230V P2 T PAUSE Sets the pause time from 2 to 120 sec Operation time is set at 90 secs working manoeuvre The motor stops after this time 11 8 RADIO RECEIVER 8 1 RECEIVER TECHNICAL SPECIFICATIONS Max n of radio transmitters that can be memorized 64 Frequency 433 92MHz Code by means of Rolling code algorithm N of combinations 4 billion 8 2 RADIO CHANNEL FUNCTIONALITY Channel 1 Start command Channel 2 AP PED command Pedestrian Opening 8 3 ANTENNA INSTALLATION A Use an antenna tuned to 433MHz Connect the tuned antenna to the antenna terminals using RG58 coaxial cable IC COSTA SHIELD ANTENNA antenna cable RG58 Y 8 4 MANUAL PROGRAMMING In the case of standard installations where no advanced functions are required it is possible to proceed to manual storage of the transmitters making reference to programming table A and to the example for basic programming 1 If you wish the transmitter to activate output 1 press pushbutton PR1 otherwise if you wish the transmitter to activate output 2 press pushbutton PR2 2 When LED DL1 starts blinking press hidden key on the transmitter LED DL1 will remain continuously lit 3 Press the key of the transmitter to be memorized LED DL1 will flash quickly to indic
24. as de potencia 1 5 mm tama o m nimo de las de se al de baja tensi n 0 5 mm tama o m nimo Hacer un puente en las entradas N C no utilizadas Poner en serie los eventuales contactos a conectar en serie en la misma entrada N C Poner en paralelo las entradas conectadas a la misma entrada N A 5 CONEXIONES Y FUNCIONES DE ENTRADAS Y SALIDAS 5 1 TABLERO DE BORNES DE POTENCIA J1 J2 LINEA 230V de Alimentaci n a 230V 50 Hz con protecci n interna de movimiento fusible 5x20 de 6 3A Conectar la fase y el neutro como se muestra en la serigrafia Utilizar un cable de tipo HO7RN F 2x1 5 T min SMART 800 Conecte el conductor amarillo verde de la red de alimentaci n al borne de tierra del aparato 41 LAMP N KEEN LUZ INTERMITENTE LUZ AMARILLA a 230V 40W max INVERSION DE ROTACION DEL MOTOR 1 1 El Eq c TJ cono COND Seel e t EX mora LC mora COM 24Vac OUT 24V 7 Salida de 24 Vca para alimentar accesorios de seguridad y control como fotoc lulas o receptores via radio sca com Intermitencialenta fase de apertura Intermitencia rapida fase de de cierre START STOP 5 2 REGLETA DE BORNES ENTRADAS SALIDAS DE BAJA TENSION J3 SCA Indicador vado abierto Con cuatro indicaciones diferentes indica el estado del automatismo Luz fija puerta abierta o tambi n parada en apertura parcial Luz apaga
25. ate that it has been memorized successfully Flashing as normal will then be resumed 4 To memorize another transmitter repeat steps 2 and 3 5 To exit memorizing mode wait for the LED to go off completely or press the key of a remote control that has just been memorized IMPORTANT NOTE ATTACH THE ADHESIVE KEY LABEL TO THE FIRST MEMORISED TRANSMITTER MASTER In the case of manual programming the first transmitter assigns the key code to the receiver this code is necessary in order to carry out subsequent cloning of the radio transmitters Hidden key 8 5 SELF LEARNING MODE PROGRAMMING This mode is used to copy the keys of a transmitter already stored in the receiver memory without acces sing the receiver The first transmitter is to be memorised in manual mode see paragraph 8 4 a Press hidden key on the transmitter already memorised b Press key T on the transmitter already memorised which is also to be attributed to the new transmitter c Within 10 s press hidden key on the new transmitter to be memorised Hidden key d Press key T to be attributed to the new transmitter e To memorise another transmitter repeat the procedure from step c within a maximum time of 10 N T2 seconds otherwise the receiver exits the programming mode TI tak f To copy another key repeat from step a having waited for the receiver to exit the programming mode T3 nd T4 or after disconnecting the receiv
26. da puerta cerrada Doble destello banda de seguridad presionada START 5 Entrada N A que permite controlar el automatismo seg n la l gica programada con los dip 1 2 3 4 S Si con la puerta cerrada se mantiene activado el mando de start se obtiene la apertura total con tipologia de funcionamiento de reloj y cuando ste se libera despu s de pausa fijado en el trimmer P2 se efectua el cierre STOP 5 Entrada N C de seguridad Cuando se activa para inmediatamente el automatismo un start sucesivo provoca siempre o una reapertura Durante el tiempo de pausa trimmer P2 un control de stop para el reenganche autom tico dejando la puerta abierta a la espera de rdenes 28 FOTO FOTO 3 Entrada N C de seguridad Cuando se activa en fase de cierre provoca la reapertura del automatismo Si se habilita tambi n en apertura con el dip 5 para temporalmente el automatismo durante el intervalo de tiempo durante el cual est ocupado AP PED a a d 5 Entrada N A de start peatonal Permite la apertura parcial de 10 segundos seg n la l gica programada con los dip 1 y 2 lt Si con la puerta cerrada se mantiene activado el mando de start peatonal se obtiene la apertura parcial con tipolog a de fun cionamiento de reloj y cuando ste se libera despu s de 10 seg de pausa se efect a el cierre dip 1 2 ON ENTRADA FINAL DE CARRERA 5 9 S Entradas N C Si se invierte el sentido de rotaci n del mot
27. e la m morisation est accomplie Elle reprend ensuite son clignotement normal 4 Pour m moriser un auter trasmetteur r p ter les tapes 2 et 3 5 Pour quitter le mode de m morisation attendre jusqu l extinction totale de la led ou bien appuyer sur la touche d une t l commande peine m moris e NOTE IMPORTANTE MARQUER LE PREMIER EMETTEUR MEMORISE AVEC L ETIQUETTE CLE MA STER Le premier metteur en cas de programmation manuelle attribue le code cl au r cepteur ce code est n ces saire pour pouvoir effectuer le clonage successif des metteurs radio Touche cach e 8 5 PROGRAMMATION MODALIT AUTO APPRENTISSAGE Cette modalit sert 8 effectuer une copie des touches d un metteur d j m moris dans le r cepteur sans acc der au r cepteur Le premier metteur doit amp tre m moris en mode manuel voir paragraphe 8 4 a Appuyer sur la touche cach e de l metteur d j m moris Appuyer sur la touche T de l metteur d j m moris que l on souhaite attribuer aussi au nouvel metteur c Appuyer avant 10 s la touche cach e du nouvel metteur m moriser Touche cach e d Appuyer sur la touche T que Ton souhaite attribuer au nouvel metteur e Pour m moriser un autre metteur r p ter depuis le pas avant un temps maximum de 10 s sinon le N T2 r cepteur sort du mode programmation TIM x f Pour copier une autre touche r p ter du pas a
28. e time set on trimmer P2 In the partial pedestrian cycle the logic is automatic with a fixed pause time of 10 sec The START control always takes priority over the partial opening cycle with full gate opening If the automation is in a state of black out on the opening limit switch FCA if the logic is set in automatic mode when power is restored the gate will close after 3 sec Dip switch 3 and 4 Select the response of the logic to the sequence of start controls Off Off Step by step type 1 open stop close stop open stop close Off On Step by step type 2 open stop close open stop close open On Off Condominium type 1 control for opening only on pause a start closes and on closure it reopens On On Condominium type 2 control for opening only on pause the start is not considered and on closure it reopens Dip 5 Off Photocells active only on closing if obscured they reverse the direction Dip 5 On Photocells active on both closing and opening if the photocells are obscured in either the closing or opening phase the automation stops until they are freed to then open Dip 6 Off Safety edge with NC contact Dip 7 Off Pre flashing off Dip 6 On Safety edge with 8 2kQ resistive contact Dip 7 On Pre flashing of 2 sec on Dip 8 Off Electric braking at limit switch off Dip 8 On Electric braking at limit switch on 7 TRIMMER ADJUSTMENT P1 TORQUE Sets the useful torque to move the gate after st
29. eggio R E ltaly Phone 39 0522 740111 Fax 39 0522 631290 Internet www oeo it E mail oeo oeo it
30. er from the power supply 9 ATTENTION It is recommended to make an installation which has all the accessories necessary to ensure operation according to current provisions always using genuine O amp O devices This equipment must be installed and used in strict compliance with the manufacturer s instructions The manufacturer cannot be held responsible for any damage deriving from improper or unreasonable use O amp O srl disclaims all liability for any inaccuracies contained in this booklet and reserves the right to make changes at any time without any prior notice whatsoever 12 TABLE A When pressing the key PR1 for channel 1 or PR2 for channel 2 for the first time the receiver sets to the programming mode Every time the key PR is pressed after that the receiver switches to the configuration for the subsequent function that is indicated by the number of flashings see table At this stage after selecting the channel PR1 or PR2 and the desired function the key T T1 T2 T3 or T4 of the transmitter will be stored in the memory of the receiver as indicated in the table for programming eh PR1 for CH1output chanel z PR2 for CH2 output chanel Automatic memory storage only trasmitter with impulse output Step by step output Cancellation of the entire receiver memory AL ZA Iw TA Banana You will exit programming mode if no memorizing is performed for 10 s
31. ers bis die LED an bleibt dr cken Sie dann die Taste T 1 2 3 oder 4 des Senders bis das Blinken fortgesetzt wird warten Sie bis die LED ausgeht oder klemmen Sie die Stromversorgung ab Jetzt ist die Taste T des Senders abgespeichert Dr cken Sie die versteckte Taste des Senders bis die LED an bleibt dr cken Sie dann die Taste T1 des Senders das Dr cken der anderen Tasten wird ignoriert bis das Blinken fortgesetzt wird warten Sie bis die LED ausgeht 10 s oder dr cken Sie zum Verlassen eine Taste des Senders Nun werden T1 und T2 automatisch auf CH1 und CH2 abgespeichert Vortgeschrittene Programierung Funktion nicht zugeordnet Funktion nicht zugeordnet Funktion nicht zugeordnet Dr cken Sie w hrend des Blinkens der LED gleichzeitig die Tasten PR1 und PR2 des Empf ngers f r eine Zeit von mehr als 10 s Die LED blinkt sehr schnell Wenn die LED ausgeht wurden alle Sender gel scht und die Betriebsweise Programmierung wird verlassen LEGENDE FUNKTION ANZAHL BLINKSIGNALE DER LED DL1 FUNKTIONSBESCHREIBUNG PROGRAMMIERWEISE 25 Indice Pagina INTRODUCCI N 27 CARACTERISTICAS PRINCIPALES 27 CARACTERISTICAS TECNICAS 27 SEGURIDAD DE LA INSTALACI N 28 CONEXIONES Y FUNCIONES DE ENTRADAS Y SALIDAS 28 5 1 TABLERO DE BORNES DE POTENCIA J1 J2 28 5 2 REGLETA DE BORNES ENTRADAS SALIDAS DE BAJA TENSION J3 28
32. erung beispielhaft gezeigt wird 1 Wird gew nscht da der Sender Ausgang 1 anspricht dr cken Sie den Knopf PR1 soll der Sender Ausgang 2 ansprechen Knopf PR2 2 Wenn die Led DL1 blinkt dr cken Sie die verborgene Versteckte Taste die Led DL1 leuchtet nun durchgehend 3 Dr cken Sie die abzuspeichernde Taste des Senders die LED DL1 blinkt schnell auf und zeigt die erfolgte Abspeicherung an Anschlie end blinkt sie normal weiter 4 Wiederholen Sie zum Abspeichern eines weiteren Senders die Schritte 2 und 3 5 Warten Sie zum verlassen der Abspeicherung bis die LED ausgeht oder dr cken Sie die Taste der soeben Versteckte abgespeicherten Funksteuerung Taste WICHTIGE ANMERKUNG KENNZEICHNEN SIE DEN ALS ERSTEN GESPEICHERTEN SENDER MIT DER SCHL SSELMARKE MASTER Der erste Sender weist bei der manuellen Programmierung dem Empf nger den Schl sselcode zu dieser Code ist erforderlich um anschlie end die Funksender klonieren zu k nnen 8 5 SELBSTERLERNUNG PROGRAMMIERUNG Auf diese Art wird im Empf nger die Tastenkopie eines bereits gespeicherten Senders erstellt ohne dabei auf das im Kasten abgeschlossene Empfangsteil zugreifen zu m ssen Der erste Handsender mu von Hand gespeichert werden siehe Abschnitt 8 4 a Den Geheimcode des bereits gespeicherten Handsenders erneut bertragen b Die gew nschte Taste T des bereits gespeicherten Handsenders dr cken die dem neuen Handsender zugeordnet werde
33. essori necessari ad assicurare il funzionamento secondo normativa vigente impiegando sempre dispositivi originali O amp O L utilizzo e l installazione di queste apparecchiature deve rispettare rigorosamente le indicazioni fornite dal costruttore che non pu essere considerato responsabile per eventuali danni derivanti da uso improprio o irragionevole La O amp O srl declina ogni responsabilit per le possibili inesattezze contenute nel seguente pieghevole e si riserva il diritto di apportare modifiche in qualsiasi momento senza preavviso alcuno TABELLAA p Programmazione Memorizzazione automatica trasmettitore con uscita impulsiva D Uscita passo passo Uscita timer Eliminazione codice Cancellazione dell intera memoria della ricevente PR1 per Uscita canale CH1 A PR2 per Uscita canale CH2 La prima pressione del tasto PR1 per canale 1 o PR2 per canale 2 imposta la ricevente in modalit programmazione Ad ogni successiva pressione del tasto PR la ricevente passa alla configurazione della funzione successiva che viene indicata dal numero di lampeggi vedi tabella Quindi dopo aver selezionato il canale PR1 o PR2 e la funzione desiderata si proceder alla memorizzazione del tasto T T1 T2 T3 o T4 della trasmittente nella memoria della ricevente come indicato nella tabella programmazione NA NA NA ananas Se per un tempo di 10 secondi non si eseguono
34. eture provoque la rouverture de l automation Si elle est activ e 5 2 BORNIER ENTREES SORTIES A BASSE TENSION J3 en ouverture aussi avec le microinterrupteur 5 elle arr te temporairement l automation pendant la dur e o il est excit 16 AP PED J Entr e N O de start pi tonnier Permet louverture partielle de 10 sec selon la logique programm e avec les microinter x 9 rupteurs 1 et 2 Si la commande de start pi tonnier est maintenue activ e lorsque le portail est ferm on obtient l ouverture lt partielle avec un type de fonctionnement horologe La fermeture s obtient 10 secondes apr s avoir rel ch la commande dip 1 2 ON Pol ENTR E FIN DE COURSE 2 2 8 Entr es N F En cas d inversion du sens de rotation du moteur ne pas oublier d inverser FCA FCC 5 3 BORNIER D ANTENNE ET LISTEL DE SECURITE 4 2 ENTREE LISTEL DE S CURIT 6 8 Avec le DIP 6 vous pouvez s lectionner le borde sensible soit en N F que avec le contact conducteur ET r sistive de 8 2kQ M M H 6 CONFIGURATION DES MICROINTERRUPTEURS Microinterrupteurs n 1 et 2 Ils s lectionnent la logique de fonctionnement Off Off Logique homme present L automation fonctionne par commandes maintenues L actionnement de start provoque une ouverture et une fermeture La l gislation interdit les commandes via radio dans la
35. ff Pas pas type 1 ouverture stop fermeture stop ouverture stop fermeture Off On Pas pas type 2 ouverture stop fermeture ouverture stop fermeture ouverture On Off Copropri t s type 1 commande d ouverture seulement en pause un start fermeture et en fermeture il rouvre On On Copropri t s type 2 commande d ouverture seulement en pause le start n est pas pris en consid ration et il rouvre en ferme ture Dip 5 Off Photocellules activ es en fermeture seulement en cas d interruption de leur faisceau elles inversent la manceuvre Dip 5 On Photocellules activees aussi bien en fermeture qu en ouverture si le faisceau des photocellules est interrompu aussi bien en phase de fermeture que d ouverture l automation s arr te jusqu au r tablissement des photocellules pour effectuer ensuite louver ture Dip 6 Off Listel sensible contact N F Dip 7 Off D sactivation du pr clignotement Dip 6 On Listel de s curit a contact r sistif de 8 2kQ Dip 7 On Activation d un pr clignotement de 2 secondes Dip 8 Off D sactivation du freinage lectrique en fin de course Dip 8 On Activation du freinage lectrique en fin de course 7 REGLAGE DES POTENTIOMETRES P1 COUPLE met au point le couple utile pour actionner le portail apr s le d collage de 1 5 secondes la puissance maximale tension r glable de 120 230V P2 T PAUSE Met au point le temps de pause de 2 120 sec Le tem
36. impostato su P2 viene effettuata la chiusura STOP 5 Ingresso N C di sicurezza Quando viene attivato arresta immediatamente l automazione e uno start successivo provoca Ka sempre una riapertura Durante il tempo di pausa un comando di stop elimina la richiusura automatica restando in attesa di comandi ue FOTO 5 Ingresso N C di sicurezza Quando viene attivato in fase di chiusura provoca la riapertura dell automazione Se viene abilitato anche in apertura tramite il dip 5 ferma temporaneamente l automazione per il tempo in cui impegnato al AP PED u 5 Ingresso N A di start pedonale Consente l apertura parziale di 10 sec secondo la logica programmata tramite i dip 1 e 2 E Se a cancello chiuso viene mantenuto attivato il comando di start pedonale si ottiene l apertura parziale con tipologia di fun zionamento a orologio e quando lo si libera dopo 10 sec di pausa viene effettuata la chiusura dip 1 2 ON INGRESSI FINECORSA S el Ingressi N C Qualora si inverta il senso di rotazione del motore ricordarsi di invertire FCA FCC 5 3 MORSETTIERA ANTENNA COSTA J4 lt lt a INGRESSO COSTA DI SICUREZZA 834 Tramite il dip 6 possibile selezionare l intervento della costa di sicurezza sia N C che a contatto resistivo S GI 8 2kQ Mo 6 CONFIGURAZIONE DEI DIP SWITCH Dip switch n 1 e 2 Selezionano la logica di funzioname
37. iodes qui affichent l tat des entr es Borniers extractibles sur les entr es basse tension Freinage lectrique fin de course pour portes nombre de cycles et inertie particuliers Sortie pour voyant lumineux portail ouvert Radio r cepteur 433 MHz int gr e LE B B R R RB RB H a Ed 5 41 Bornier moteur condensateur 2 Bornier d alimentation 3 Bornier entr es sorties 8 basse tension J4 Bornier listel de s curit et d antenne SW1 Touche de commande START SW2 Touche de commande AP PED SW3 Microinterrupteur P1 Potentiom tre couple P2 Potentiom tre temps de pause F1 Fusible ligne 6 3A F2 Fusible de basse tension a 100mA 3 CARACTERISTIQUES TECHNIQUES Alimentation 230Vac 10 50 Hz Sortie moteur 230Vac 1 5A max Sortie clignotant 230Vac 40W max Sortie SCA 24Vac 3W max Sortie accessoires 24Vca 3W max 15 Pour atteindre le degr de s curit requis par la l gislation en vigueur lisez attentivement et suivez les prescriptions suivantes 4 SECURITE DE L INSTALLATION Tous les branchements dans le bornier doivent amp tre effectu s apr s avoir lu attentivement les indications report es dans ce mode d emploi et en suivant les regles g n rales et de bonne technique qui reglent la r alisation des installations lectriques Pr v
38. irection of rotation is reversed reverse FCA FCC lt o eg d If the pedestrian start control is kept active with the gate closed there is partial opening with timer type operation and ol S o d j 5 3 J4 TERMINAL BLOCK SAFETY EDGE ANTENNA SAFETY EDGE INPUT Trough Dip Switch 6 is possible to select the activation of the safety edge both in N C contact and or resistive contact 8 2kQ COSTA COSTA SHIELD ANTENNA E Eq El 6 DIP SWITCH CONFIGURATION Dip switches 1 and 2 Select the functioning logic Off Off Dead man logic The automation works for held controls The start control opens once and closes once Regulations prohibit controls via radio with dead man logic Off On Semiautomatic logic The automation works for pulse controls without automatic reclosing So at the end of opening in both the normal and pedestrian cycle to control closure it is necessary to use respectively the start or pedestrian start On Off Automatic logic type 1 The automation works with pulses In the normal cycle after the opening phase automatic closing is activated after the time set on trimmer P2 In the partial pedestrian cycle the logic is semiautomatic so at the end of opening a pulse on the start ped On On Automatic logic type 2 The automation works with pulses In the normal cycle at the end of the opening phase automatic closing is activated after th
39. is par M Wh Wh A Ww M W une pause d environ 1 s RO ID m al Elimination Fonction non associ e du code 6 clignotements suivis par une Wh Wh M Wh Wh Wh W Pendant le clignotement de la led appuyer Effacement de pause d environ 1 s 1101 01 0 11 1 6 1 simultan ment sur les boutons PR1 et PR2 du ATTENTION Cette op ration efface de la m moire du r cepteur r cepteur pendant un temps sup rieur 10 s La led clignote tr s rapide A l extinction des led Maintenant toutes les metteurs sont annul s et on sort de la sur le canal 2 modalit de programmation toute la m moire du r cepteur toutes les radiocommandes m moris es tant sur le canal 1 que LEGENDE NUMERO DE CLIGNOTEMENTS DE LA LED DL1 FONCTION DESCRIPTION DE LA FONCTION PROCEDURE DE PROGRAMMATION 19 Inhalt Seite 1 EINLEITUNG 21 2 HAUPTEIGENSCHAFTEN 21 3 TECHNISCHE EIGENSCHAFTEN 21 4 SICHERHEIT DER INSTALLATION 22 5 ANSCHLUSS UND FUNKTION DER EIN UND AUSGANGE 22 5 1 LEISTUNGSKLEMMENBRETT J1 J2 22 5 2 KLEMMENBRETT NIEDERSPANNUNGS EINGANGE AUSGANGE 3 22 5 3 ANSCHLUSSKLEMMENBRET ANTENNE SICHERHEITSKOPFFLANKE J4 23 6 KONFIGURATION DER DIP SWITCH 23 7 TRIMMEREINSTELLUNG 23 8 STECKFUNKEMPFANGER 24 8 1 TECHNISCHE DATEN EMPFANGER 24 8 2 FUNKTION FUNKKANAL 24 8 3 ANTENNENINSTALLATION 24 8 4 MANUELLE PROGRAMMIERUNG 24 8 5 SELBSTERLERNUNG PROGRAM
40. lassen wird erfolgt nach einer Pause das Schlie en des Tors STOP s NC Sicherheitseingang Bei Aktivierung dieses Eingangs wird die Automation sofort angehalten und ein darauffolgender 5 6 Start bewirkt immer das ffnen W hrend der Pausenzeit Trimmer P2 unterbricht eine Stopp Steuerung das Schlie en und das Tor bleibt in Erwartung weiterer Steuerungen ge ffnet EY PRE FOTO NC Sicherheitseingang Bei Aktivierung w hrend der Schlie phase wird die Automation wieder ge ffnet Wenn mittels dip 5 auch in ffnen aktiviert wird die Automation so lange angehalten wie der Eingang belegt ist FOTO COM AP PED NO Eingang f r Start Fu g nger Erlaubt das teilweise ffnen in 10 Sek gem der mit den dip 1 und 2 programmierten rs Logik Wenn bei geschlossenem Tor die Steuerung Start Fu g nger gedr ckt gehalten wird erfolgt eine partielles ffnen AP PED des Tors mit Uhrbetriebtypologie und wenn die Start Steuerung losgelassen wird erfolgt nach einer Pause von 10 Sekunden das Schlie en des Tors dip 1 2 ON 6 lt P o EINGANG ENDANSCHLAG rh 2 S Eing nge N C Um die Motordrehrichtung umzukehren kehren sie bitte auch die Klemmen FCA FCC 5 3 ANSCHLUSSKLEMMENBRET ANTENNE SICHERHEITSKOPFFLANKE J4 lt lt 9 Z EINGANG SICHERHEITSKOPFFLANKE gt oz E Uber den DIP 6 kann der Betrieb des Sicherheitsr ckens sowohl N G als auch auf dem Resistivkontakt Sd 5
41. logique homme present Off On Logique semi automatique L automation fonctionne par impulsions sans la refermeture automatique A la fin de l ouverture que ce soit en cycle normal ou pi tonnier pour commander la fermeture il faut agir respectivement sur le start ou le start pi tonnier On Off Logique automatique type 1 L automation fonctionne par impulsions Pendant le cycle normal apr s la phase d ouverture la refermeture automatique est activee apr s le d lai mis au point sur le potentiom tre P2 Pendant le cycle partiel pi tonnier la logique est semi automatique par cons quent pour fermer apr s l ouverture il faut donner une impulsion sur l entr e de start pi t On On Logique automatique type 2 L automation fonctionne par impulsions Pendant le cycle normal la refermeture automatique est activ e apr s le d lai mis au point sur le potentiom tre P2 Pendant le cycle partiel pi tonnier la logique est automatique avec un temps de pause fixe de 10 sec Le commande de START est toujours prioritaire sur le cycle d ouverture partielle en r alisant l ouverture totale du portail En cas d interruption de courant sur le microinterrupteur d ouverture FCA si la logique est s lectionn e en modalit automatique le portail se fermera apr s le temps de pause pr vu 3 sec Microinterrupteurs 3 et 4 Ils s lectionnent_la r ponse de la logique la sequence de commandes de start Off O
42. mm Ifthere isn t one already install a residual current device with a threshold of 30 mA Check the effectiveness of the grounding system and connect to it all the parts of the automation fitted with a terminal or grounding cable Fit at least one external warning device such as a traffic light or flashing light along with a warning or danger sign Fit all the safety devices required by the type of installation taking into consideration the risks it can cause Separate the power lines min sect 1 5 mm from the low voltage signal lines min sect 0 5 mme in the ducts Fit jumpers in the N C inputs not used Set in series any contacts to be connected in series with the same N C input Setin parallel the inputs connected to the same N O input 5 INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS 5 1 J1 J2 POWER TERMINAL BLOCK LINE 230V AN 230V 50Hz power supply with mov internal protection and 6 3A fuse 5x20 Connect the phase and neutral as shown on the screen printing Use a cable type HO7RN F 2x1 5 E min Connect the yellow green wire of the power supply mains to the earth terminal of the appliance FLASHING LIGHT YELLOW at 230V 40W max SWITCH THE MOTOR ROTATION J1 J1 El im c TJ cono COND Del eee mora LC mora 5 2 J3 LOW VOLTAGE INPUT OUTPUT TERMINAL BOARD COM 24Vac OUT 24V 24Vac output to power safety and c
43. ms 2 MAIN CHARACTERISTICS Microprocessor logic LEDs displaying input status Extractable terminal boards on low voltage inputs Electric braking with limit switches for gates with special number of cycles and inertia Output for gate open indicator light Integrated radio receiver 433Mhz LEE A E E BR B J1 Terminal board 2 Power terminal block J3 Low voltage input output terminal board J4 Terminal Block Safety edge and Antenna SW1 START control button SW2 AP PED control button SW3 Dip Switch P1 Torque trimmer P2 Pause time trimmer F1 Line fuse 6 3A F2 Low tension fuse 100mA 3 TECHNICAL SPECIFICATIONS Power supply 230Vac 10 50 Hz Motor output 230Vac 1 5A max Traffic light 230Vac 40W max SCA output 24Vac 3W max Accessory output 24Vac 3W max 4 INSTALLATION SAFETY In order to reach the level of safety required by current regulations read the following prescriptions carefully 1 2 3 4 00 JO O1 e Make all the connections in the terminal block after carefully reading the instructions given in this manual and observing the general rules and technical standards governing electrical systems Upstream from the installation fit an omnipole miniature circuit breaker with a contact gap of at least 3
44. n soll c Den Geheimcode des neuen zu speichernden Handsenders bertragen d Die gew nschte Sendetaste dr cken die dem neuen Hnadsender zugeordnet werden soll e Die Speicherung weitere Handsender muss innerhalb von 10 Sekunden ab Schritt c erneut begonnen N werden andernfalls verl t der Empf nger die Programmierung Till x f F r das Speichern einer weiteren Taste des gleichen Handsenders muss zuerst der Programmiermodus T4 Verlassen werden als alternative kann man auch die Stromversorgung des Empf ngers kurz T3 K is unterbrechen und nachfolgend ab Schritt a verfahren Versteckte Taste T2 9 WICHTIGE HINWEISE Es wird empfohlen bei der Installation alle erforderlichen Teile zu verwenden die f r einen sicheren Betrieb gem den geltenden Ge setzen erforderlich sind Zu diesem Zweck sind immer Originalteile von O amp O zu verwenden Der Gebrauch und die Installation dieser Teile und Ger te muss strikt gem den Anweisungen des Herstellers erfolgen der nicht f r Sch den haftet die auf einen unsachgem en oder falschen Einsatz zur ckzuf hren sind O amp O srl haftet nicht f r eventuelle Ungenauigkeiten in dem Prospekt und beh lt sich das Recht vor jederzeit und ohne Vorank ndigung Ab nderungen an seinen Produkten vorzunehmen 24 TABELLE A Automatische speicherung f r Sender mit Impulsausgang Ausgang Schrittschaltung L schen des
45. nte memorizzati su CH1 e CH2 Programmazione Avanzata Funzione non associata Funzione non associata Funzione non associata Durante il lampeggio del Led premere simultaneamente i pulsanti PR1 e PR2 della ricevente per un tempo superiore ai 10s Il led lampeggia molto veloce Allo spegnimento del led Ora tutte le trasmittenti sono cancellate e si esce dalla modalit programmazione FUNZIONE NUMERO LAMPEGGI DEL LED DL1 DESCRIZIONE DELLA FUNZIONE PROCEDURA DI PROGRAMMAZIONE Contents Page 1 INTRODUCTION 9 2 MAIN CHARACTERISTICS 9 3 TECHNICAL SPECIFICATIONS 9 4 INSTALLATION SAFETY 10 5 INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS 10 5 1 J1 J2 POWER TERMINAL BLOCK 10 5 2 J3 LOW VOLTAGE INPUT OUTPUT TERMINAL BLOCK 10 5 3 J4 TERMINAL BLOCK SAFETY EDGE ANTENNA 11 6 DIP SWITCH CONFIGURATION 11 7 TRIMMER ADJUSTMENT 11 8 RADIO RECEIVER 12 8 1 RECEIVER TECHNICAL SPECIFICATIONS 12 8 2 RADIO CHANNEL FUNCTIONALITY 12 8 3 ANTENNA INSTALLATION 12 8 4 MANUAL PROGRAMMING 12 8 5 SELF LEARNING MODE PROGRAMMING 12 9 ATTENTION 12 TABLE A 13 M oso DEC SC Instructions for installation and use 1 INTRODUCTION li The DEC SC control unit has been designed to control the automations SMART 800 and MEGA 2000 for sliding doors The considerable number of logic units available permits satisfying even special operating conditions on syste
46. nto Off Off Logica a uomo presente L automazione funziona per comandi mantenuti Il comando di start una volta apre e una volta chiude La normativa vieta comandi via radio nella logica a uomo presente Off On Logica semiautomatica L automazione funziona per comandi ad impulsi senza la richiusura automatica Quindi a fine apertura sia nel ciclo normale che pedonale per comandare la chiusura occorre agire rispettivamente sullo start o start pedonale On Off Logica automatica tipo 1 L automazione funziona per impulsi Nel ciclo normale terminata la fase di apertura attivata la richiusura automatica dopo il tempo impostato sul trimmer P2 Nel ciclo parziale pedonale la logica semiautomatica quindi al termine dell apertura per chiudere occorre un impulso sull ingresso di start ped On On Logica automatica tipo2 L automazione funziona per impulsi Nel ciclo normale al termine della fase di apertura attivata la richiusura automatica dopo il tempo impostato sul trimmer P2 Nel ciclo parziale pedonale la logica automatica con un tempo pausa fisso di 10 sec Il comando di START sempre prioritario sul ciclo di apertura parziale realizzando l apertura totale del serramento Nel caso in cui l automazione si trovi in condizioni di black out sul finecorsa di apertura FCA se la logica impostata in modalit automatica al ritorno della corrente il cancello si richiuder dopo 3 sec Dip switch n
47. ontrol accessories such as photoelectric cells or radio receivers SCA Passageway open indicator light With four different indicators it shows the automation status sca com Slow blinking opening phase Fast blinking closing phase Steady light gate open or even stopped with partial opening Light off gate closed Double Flashing safety edge squeezed START E 5 N O input used to control the automation according to the programmed logic with the dip switches 1 2 3 4 7 5 If the start control is kept active with the gate closed there is total opening with timer type operation and when it is freed after the pause time set on trimmer P2 the gate is closed ad STOP 2 5 N C safety input When it is activated it stops the automation immediately and a subsequent start always causes a N o reopening During the pause time trimmer P2 a stop control eliminates automatic reclosure leaving the gate open waiting for commands 10 FOTO 5 N C safety input When it is activated in the closing phase it causes the automation to reopen If it is enabled also in the ope ning phase with dip switch 5 it temporarily stops the automation for the time for which it is engaged au AP PED a Pedestrian start N O input Allows 10 sec partial opening according to the logic programmed with the dip switches 1 2 a lt when it is freed after a pause the gate is closed dip 1 2 ON LIMIT SWITCH INPUT N C inputs If the d
48. or recordar que tambi n hay que invertir FCA FCC 5 3 BORNERA DE BORDE DE SEGURIDAD Y ANTENA J4 lt lt 9 ENTRADA BORDE DE SEGURIDAD ZS E Con el dip nr 6 se puede seleccionar la activaci n de la banda de seguridad sea en n c que con contacto Sd 5 resistivo de 8 283 E E 6 CONFIGURACI N DE LOS DIP SWITCH Dip switch n 1 y 2 Seleccionan la l gica de funcionamiento Off Off L gica por accionamiento manual El automatismo funciona con controles mantenidos El mando de start una vez abre y una vez cierra La normativa proh be los mandos v a radio en la l gica por accionamiento manual Off On L gica semi autom tica El automatismo funciona por mandos de impulsos sin el reenganche autom tico Por lo tanto al final de la apertura tanto en el ciclo normal como en el peatonal para ordenar el cierre es necesario usar respectiva mente el start o start peatonal On Off L gica automatica tipo 1 El automatismo funciona por impulsos En el ciclo normal terminada la fase de apertura se activa el reenganche autom tico despu s del tiempo fijado en el trimmer P2 En el ciclo parcial peatonal la l gica es semi autom tica por lo tanto al final de la apertura para cerrar es necesario un impulso en la entrada de start peatonal On On L gica autom tica tipo 2 El automatismo funciona por impulsos En el ciclo normal al final de la fase de apertura se activa el
49. oyez en amont de l installation un disjoncteur omnipolaire avec une distance d ouverture des contacts de 3 mm min Installez o il n est pas pr vu un interrupteur diff rentiel avec un seuil de 30 mA V rifiez l efficacit de la mise la terre et reliez y tous les composants de l automation dot s d une borne ou d un fil de terre Pr voyez la pr sence d au moins un signal externe de type feux rouges ou clignotant ainsi qu un panneau signalant le danger ou d avertissement Appliquez tous les dispositifs de s curit requis par le type d installation en prenant en compte les risques qu elle peut provoquer Dans les goulottes s parez les lignes d alimentation sec min 1 5 mm de celles de signal en basse tension sec min 0 5 mm Court circuitez les entr es N F inutilis es Disposez en s rie les contacts ventuels a brancher en s rie a la m me entr e N F Disposez en parallele les entr es reli es a la m me entr e N O 5 CONNEXIONS ET DESCRIPTION DES ENTR ES ET DES SORTIES 5 1 BORNIER D ALIMENTATION J1 2 LIGNE 230V Alimentation 230V 50Hz avec protection interne mov et fusible 5x20 de 6 3A Branchez la phase et le neutre comme report sur la plaquette Utilisez un cable type HO7RN F 2x1 5 T min SMART 800 Brancher le conducteur jaune vert du r seau d alimentation 8 la borne deterre de l appareil Ji LAMP Bsns CLIGNOTANT FEU JAUNE a 230V 40W max
50. ps de fonctionnement est pr r gl sur 90 sec de man uvre utile dur e au bout de laquelle le moteur s arr te 17 8 RECEPTEUR RADIO 8 1 DONN ES TECHNIQUES RECEPTEUR N max radio amp metteurs m morisables 64 Fr quence 433 92MHz Code moyen Algorithme rolling queues N combinaisons 4 milliards 8 2 FONCTION CANAL RADIO Canal 1 commande de START Canal 2 commande d ouverture pi tonne AP PED 8 3 INSTALLATION ANTENNE ff Utiliser une antenne accord e sur 433MHz Rac corderl ventuelle antenne accord e sur les bornes Ann antenne Utiliser un c ble coaxial RG58 amp COSTA SHIELD c ble antenne RG58 Y ANTENNA 8 4 PROGRAMMATION MANUELLE En cas d installations standard qui n exigent pas de fonctions avanc es il est possible d effectuer la m morisa tion manuelle des metteurs se r f rant au tableau de programmation A et l exemple pour la programmation de base 1 Si Pon d sire que l metteur active la sortie 1 appuyer sur la touche PR1 ou bien si l on d sire que l metteur active la sortie 2 appuyer sur la touche PR2 2 Quand la led DL1 clignote appuyer sur la touche cach e P1 de l metteur la led DL1 restera allum e de mani re fixe 3 Appuyez sur la touche de m morisation de l metteur la Del DL1 se met clignoter rapidement pour signaler qu
51. r par P2 Trimmer tiempo pausa F1 Fusibile linea 6 3A F2 Fusible de bajo voltaje a 100mA 3 CARACTERISTICAS TECNICAS Alimentaci n 230Vca 10 50 Hz Salida motor 230Vca 1 5A max Salida luz intermitente 230Vca 40W max Salida SCA 24Vca 3W max Salida accesorios 24Vac 3W max 27 4 SEGURIDAD DE LA INSTALACION Para que se alcance el grado de seguridad requerido por la normativa vigente lean atentamente las siguientes prescripciones 1 10 Realicen todas las conexiones en el tablero de bornes leyendo atentamente las indicaciones incluidas en este manual y respetando las normas generales de buena t cnica que regulan la ejecuci n de las instalaciones el ctricas Preparar antes de la instalaci n un interruptor magnetotermico omnipolar con una distancia de apertura de los contactos de un minimo de 3 mm Instalar si no est previsto un interruptor diferencial con umbral 30 mA Comprobar la eficacia de la instalaci n de toma de tierra conectar a sta todas las partes del automatismo provistas de borne o cable de tierra Prever la presencia de al menos un dispositivo de se alaci n exterior de tipo por sem foro o luz intermitente acompa ado de un cartel de indicaci n de peligro o de aviso Aplicar todos los dispositivos de seguridad requeridos por el tipo de instalaci n considerando los riesgos que sta puede causar Separar en las canalizaciones las l ne
52. raggiunga il grado di sicurezza richiesto dalla normativa vigente leggere attentamente le seguenti prescrizioni 1 Realizzare tutti i collegamenti in morsettiera leggendo attentamente le indicazioni riportate in questo manuale ed osservando le norme generali e di buona tecnica che regolano l esecuzione degli impianti elettrici 2 Predisporre a monte dell installazione un interruttore magnetotermico omnipolare con distanza di apertura dei contatti di min 3 mm 3 Installare ove non sia previsto un interruttore differenziale con soglia 30 MA 4 Verificare l efficacia dell impianto di messa a terra e collegare a questa tutte le parti dell automazione provviste di morsetto o cavo di terra 5 Prevedere la presenza di almeno un dispositivo di segnalazione esterna di tipo semaforico o lampeggiante affiancato da un cartello segnaletico di pericolo o di avviso 6 Applicare tutti i dispositivi di sicurezza richiesti dalla tipologia dell installazione considerando i rischi che essa pu causare 7 Separare nelle canalizzazioni le linee di potenza sez min 1 5 mm da quelle di segnale in bassa tensione sez min 0 5 mm 8 Ponticellare gli ingressi N C non utilizzati 9 Disporre in serie eventuali contatti da collegare in serie allo stesso ingresso N C 10 Disporre in parallelo gli ingressi collegati al medesimo ingresso N A 5 COLLEGAMENTI E FUNZIONALITA DI INGRESSI E USCITE 5 1 MORSETTIERA DI POTENZA J1 2
53. reenganche autom tico despu s del tiempo fijado en el trimmer P2 En el ciclo parcial peatonal la l gica es autom tica con un tiempo de pausa fija de 10 seg El comando de START es siempre prioritario en el ciclo de apertura parcial realizando la apertura total del cierre En el caso de que el automatismo se encuentre en condiciones de corte de energ a en el tope de apertura FCA si la l gica est fijada en modalidad autom tica al volver la corriente la puerta se volver a cerrar despu s 3 sec Dip 3 y 4 Seleccionan la respuesta de la l gica a la secuencia de comandos de start Off Off Paso paso tipo1 abre stop cierra stop abre stop cierra Off On Paso paso tipo2 abre stop cierra abre stop cierra abre On Off Comunitario tipo1 comando s lo de apertura en pausa un start cierra y en cierre vuelve a abrir On On Comunitario tipo2 comando s lo de apertura en pausa el start no se considera y en cierre vuelve a abrir Dip 5 Off Fotoc lulas activas s lo en cierre en caso de tapado invierten la maniobra Dip 5 On Fotoc lulas activas tanto en cierre como en apertura si las fotoc lulas se tapan tanto en fase de cierre como de apertura el automatismo se para hasta que se liberan para efectuar despu s siempre una apertura Dip 6 Off Borde sensible a contacto N C Dip 7 Off Pre intermitencia exclu da Dip 6 On Borde de seguridad a contacto resistivo de 8 2kQ Dip 7 On Pre intermitencia de 2 seg conectada Dip 8 Off
54. riorit t bez glich des partiellen ffnungszyklus und bewirken das komplette ffnen des Tors Falls die Automation sich am ffnungsendschalter FCA im Zustand Blackout befindet und die Logik auf den Automatikmodus eingestellt ist wird das Tor bei Wiederherstellung der Stromversorgung nach 3 Sekunden geschlossen Dip 3 und 4 Dienen zum Einstellen der Antwort der Logik auf die Startbefehlsequenz Off Off Schritt Schritt Typ1 ffnen Stopp Schlie en Stopp ffnen Stopp Schlie en Off On Schritt Schritt Typ2 ffnen Stopp Schlie en ffnen Stopp Schlie en ffnen On Off Mehrfamilienhaus Typ 1 Steuerung nur ffnen Start w hrend Pause schlie t und Start w hrend Schlie en ffnet On On Mehrfamilienhaus Typ 2 Steuerung nur ffnen Start w hrend Pause wird nicht ber cksichtigt und Start w hrend Schlie en ffnet Dip 5 Off Fotozellen nur w hrend des Schlie ens aktiv Bei Verdunkelung wird die Bewegungsrichtung umgekehrt Dip 5 On Fotozellen sowohl w hrend des Schlie ens als w hrend des ffnens aktiv Wenn die Fotozellen w hrend der Schlie oder der ffnungsphase verdunkelt werden wird die Automation angehalten bis die Fotozellen wieder in Licht sind und nehmen dann den ffnungsvorgang wieder auf Dip 6 Off Kopfflanke spricht auf N G Kontakt an Dip 7 Off Vorblinken ausgeschlossen Dip 6 On Sicherheitskopfflanke mit ohmschem Kontakt 8 2kQ Dip 7 On Blinken 2 Sek eingeschaltet Dip 8 Off Elektrische
55. se indica en la tabla de programaci n Programaci n Standard Pulsar la tecla oculta de la unidad transmisora hasta que el led quede encendido luego pulsar la tecla T 1 2 3 6 4 de la unidad transmisora hasta que vuelva a parpadear esperar que el Led se apague o interrumpir la alimentaci n Entonces la tecla T de la unidad transmisora ha sido memorizada Pulsar la tecla oculta de la unidad transmisora hasta que el led quede encendido luego pulsar la tecla T1 de la unidad transmisora si se pulsan otras teclas las mismas no tienen efecto hasta que vuelva a parpadear esperar que el Led se apague 10 s o pulsar una tecla para salir Entonces T1 y T2 quedan memorizados automaticamente en CH1 y CH2 Programaci n Avanzada Funci n no asociada Funci n no asociada Funci n no asociada Mientras el Led parpadea pulsar simult neamente los pulsadores PR1 e PR2 de la unidad receptora durante un lapso superior a los 10 s El led parpadea muy rapido Cuando el led se apaga todas las unidades transmisoras son borradas y se sale del modo de programaci n LEYENDA FUNCION NUMERO DE CENTELLEOS DEL LED DL1 DESCRIPCION FUNCION PROCEDIMIENTO DE PROGRAMACION 31 O amp O NOTE NOTES REMARQUES ANMERKUNGEN NOTAS INSTALLATORE INSTALLER INSTALLATEUR INSTALLATEUR INSTALATOR 035370 ver 2 24 09 10 O amp O S r l Via Europa 2 42015 Corr
56. uir tambi n al nuevo transmisor Tecla oculta c Presionar antes de 10 s la tecla oculta del nuevo transmisor que se desea memorizar d Presionar la tecla T que se desea atribuir al nuevo transmisor e Para memorizar otro transmisor repetir desde el paso c dentro de un tiempo maximo de 10 segundos 1 Td en caso contrario el receptor sale de la modalidad de programaci n T3 nd T4 Para copiar otra tecla repetir desde el paso a esperando a que se salga de la modalidad de progra maci n 0 cortando el suministro de corriente al receptor 9 ADVERTENCIAS Se recomienda efectuar una instalaci n que prevea todos los accesorios necesarios para asegurar el funcionamiento seg n la normativa vigente usando siempre dispositivos originales O amp O La utilizaci n y la instalaci n de estos aparatos debe respetar rigurosamente las indicaciones ofrecidas por el fabricante que no puede ser considerado responsable por posibles da os derivados de un uso impropio 0 irracional O amp O declina cualquier responsabilidad por posibles inexactitudes contenidas en este folleto y se reserva el derecho de aportar las modi ficaciones necesarias en cualquier momento sin ningun tipo de preaviso 30 TABLA A Memorizaci n automatica par trasmisor con salida impulsiva Salida paso paso Salida temporizador Eliminaci n c digo Cancelaci n de toda la memoria del receptor A Sat PR1 p