1.                                               1   IEC MAINS INPUT CONNECTOR  2   MAINS SWITCH  3   FUSE HOLDER AND VOLTAGE SELECTOR    22 MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA  4 2 1 EQUIPMENT MAINS INPUT MODULE AND VOLTAGE SELECTOR    The equipment mains input module provides the connection point for the power of the equipment s  internal electronics  The mains input module incorporates the mains input socket  the main input voltage  selector and in line mains fuses    WARNING  Before the unit is powered up the operator should check that the mains input voltage  indicated on the power input module corresponds to the mains voltage supply to which it is to be  connected  and that the correct mains fuse type for the selected mains voltage has been inserted     4 2 2 POWER ON OFF SWITCH    POWER ON OFF mechanical switch is used to control power to the equipment  To power the  equipment  press the switch in the direction of the 1  i e  right side     When the equipment is powered the front panel will illuminate  Pressing the switch in the O direction  will cut power to the equipment  this operation allows the switch to be used as a emergency stop switch   in the event of any fault              4 3 FRONT PANEL  1 2 3 4 5 6            y ta y  SEMA ES S       CUT BEND COAG    2                      9     mm   106          9 8 7  1 Key for output power decrease 6 COAG key  2 Output power display 7 Pen holder conn
2.                  1 Bot  n para bajar la potencia 6 Bot  n para selecc  la coag  COAG  2 Display de la potencia 7 Conector para mango activo   3 Bot  n para aumentar la potencia 8 Conector para mango neutro   4 Bot  n para seleccionar el corte CUT 9 Conector para pedal    5 Bot  n para selecc  corte coagulaci  n BLEND  4 3 1 BOTONES DE USO    Los botones se subdividen en dos grupos  Los dos botones que se hallan ubicados debajo del display  permiten aumentar o bajar la potencia de salida  mientras que los tres botones selectores de corriente se  hallan en la parte izquierda del aparato    La funci  n de los botones selectores de corriente es la siguiente         CUT    TAGLIO    Al pulsar este bot  n  se selecciona la corriente de corte monopolar CUT  esto es  una corriente sinusoidal  pura  que el aparato suministra  si se activa el pedal  El factor de amplitud de la corriente de corte  monopolar es  1 5  El led verde iluminado indica que se ha seleccionado la modalidad corriente de corte   9  BLEND  MIX    Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 33    GIMA SpA DIATERMO 106   Al pulsar este bot  n  se selecciona la corriente de corte coagulaci  n monopolar BLEND  esto es   corriente sinusoidal modulada  que el aparato suministra  cuando se activa el pedal  El factor de amplitud  de la corriente de corte monopolar es  1 8  El led verde iluminado indica que est   seleccionada la    modalidad corriente de corte coagulaci  n 1         COAG 
3.     operatore  per il servizio  riferirsi a personale qualificato       MA126IGBEa    Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones       DIATERMO 106 GIMA SpA       1  INTRODUCTION       1 1 CHECK LIST    Check that all the items and accessories which had been ordered have been delivered  according to the  following list   Ref Nr GMA10100 05A DIATERMO 106 Unit    Ref Nr  00100 03 Unit mains cable 2 meters long   Ref  Nr  00404 08 Cable for connection of the reference electrode  Ref  Nr  5365 Reference electrode   Ref  Nr  00301 00 Pedal switch   Ref  Nr  00500 03 Kit of 6 assorted tip   Ref  Nr  MA126IGBE Instruction s Manual    1 2 GENERAL DESCRIPTION    DIATERMO 106  High Frequency Surgical Equipment  provides the facility to carry out monopolar  minor surgery   The equipment is designed for desk top use   The most advanced electronic components and circuitry including LSI microcontrollers are applied to  provide all the prerequisite for safe and reliable operation   In this way most of the thermic problems  and the need for cooling fans  very dangerous for the batterium  diffusion in the health care rooms  have been overcome   Control of the unit is via the front panel keys and display  mains inlet and on off switch are on the rear  panel   The type of surgical operation which can be carried out are those where monopolar minor electrosurgical  cutting or coagulation is requested   Use of DIATERMO 106 is restricted to trained medical personnel  
4.    COAGULO    Al pulsar este bot  n  se selecciona la corriente de coagulaci  n monopolar COAG  esto es  la corriente  sinusoidal modulada  que el aparato suministra  si se activa el pedal  El factor de amplitud de la  corriente de corte monopolar es  2 5  El led verde iluminado indica que est   seleccionada la modalidad  corriente de corte     4 3 2 CONECTORES    Conector del pedal  Este es el punto donde se conecta el pedal  El pedal controla el suministro de la corriente monopolar     O  gt   Conector Placa del Paciente  Este es el punto donde se conecta la Placa del Paciente       O  gt   Conector del mango Gas  Este es el punto donde se conecta el mango     4 3 3 SENALES LUMINOSAS DE ADVERTENCIA          Para proteger el aparato contra la sobretemperatura  cuando la temperatura del interior del mismo supera  los 75   C  los display centellean  En su caso  hay que interrumpir la emisi  n y aguardar hasta que la  temperatura interior baje hasta valores aceptables     34 MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA       5  CARACTER  STICAS T  CNICAS       5 1 CARACTER  STICAS GENERALES    Descripci  n del aparato    Aparato electroquir  rgico de alta frecuencia para cirug  a mayor monopolar y bipolar  El aparato permite  ajustar con gran precisi  n el nivel de potencia de salida y seleccionar el efecto coagulante  a trav  s del  factor de amplitud adecuado           Carcasa   Carcasa met  lica  para uso sobre
5.   Qualsiasi danno dovrebbe  essere notificato immediatamente al vettore    BM Togliere l apparecchio dall imballo e studiare con attenzione la documentazione e le istruzioni  operative fornite  La tensione di rete  indicata al di sopra dell ingresso dell alimentazione     deve  essere uguale alla tensione di rete locale  frequenza di rete  50   60 Hz     BM La predisposizione della corretta tensione di alimentazione si esegue nel modo descritto    E  A B  Estrarre il cassetto portafusibile dal modulo di alimentazione    E  C  Inserire i fusibili facendo riferimento alla seguente tabella    Tensione di rete 110 120 V Fusibile 2 A T Ritardato 5 x 20 mm  Tensione di rete 220 240 V Fusibile 1 A T Ritardato 5 x 20 mm   E  D  Estrarre e ruotare la parte amovibile in modo da leggere nella finestra  E  la tensione   corretta   rinserire il portafusibili nel modulo   MEL  AR   BM Connettere il cavo di alimentazione ad una presa rete avente una buona connessione di terra    IL FUNZIONAMENTO DELLA APPARECCHIATURA SENZA CONNESSIONE DI TERRA E   PROIBITO    BM Posizionare l apparecchiatura in modo tale che ci sia sufficiente spazio nelle fessure di  ventilazione dietro l unit    Le fessure di ventilazione dietro l apparecchio devono essere  mantenute libere  La circolazione dell aria non deve essere limitata in alcun modo    WE Far funzionare l apparecchiatura soltanto in ambiente secco  Qualsiasi condensa che si verifichi  deve essere fatta evaporare prima di mettere in funzione l appare
6.  Manual   Manual de Instrucciones MA126IGBEa 11    GIMA SpA DIATERMO 106  ATTENZIONE  Prima di accendere l apparecchiatura  l operatore dovrebbe accertarsi che la tensione di  rete indicata nel selettore di tensione corrisponda alla tensione alla quale    connessa e che siano stati  inseriti fusibili appropriati alla tensione selezionata     4 2 2 INTERRUTTORE DI ALIMENTAZIONE     L interruttore meccanico di alimentazione    usato per inserire l alimentazione della apparecchiatura  Per  inserire l alimentazione dell apparecchiatura  premere l interruttore in direzione 1   nella parte destra    Quando l alimentazione    inserita  il pannello frontale    illuminato  Premendo l interruttore in direzione 0  l alimentazione sar   disinserita  questa operazione permette di usare l interruttore meccanico quale  interruttore di emergenza nella evenienza di un qualsiasi guasto     4 3 PANNELLO FRONTALE            2  i    cana N                               1 Tasto per diminuire la potenza 6 Tasto per selezionare COAG  coagulo   2 Visualizzatore potenza 7 Uscita manipolo attivo   3 Tasto per aumentare la potenza 8 Uscita riferimento   4 Tasto per selezionare CUT  taglio  9 Connettore pedale    5 Tasto per selezionare BLEND  mix   4 3 1 PULSANTI D USO    I pulsanti sono divisi in due gruppi  i due pulsanti posti sotto il display per aumentare o diminuire la  potenza di uscita e i tre pulsanti selettori di correnti posti sulla sinistra dell apparecchiatura La funzione  di ciascuno dei p
7.  PARTS INSIDE  REFER SERVICING TO QUALIFIED PERSONNEL          1  TOMA DE ALIMENTACION    2  INTERRUPTOR DE LA ALIMENTACION ji  3  PORTAFUSIBLES CON SELECTOR DE TENSION    32 MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA  4 2 1 MODULO DE ALIMENTACION DEL APARATO Y SELECTOR DE TENSION    El m  dulo de alimentaci  n del aparato es el punto donde se conecta la alimentaci  n de la parte  electr  nica que se encuentra el interior del mismo  Adentro del m  dulo de alimentaci  n mencionado se  encuentran el conector de alimentaci  n y los fusibles de l  nea  El selector de tensi  n est   en el interior  del m  dulo de alimentaci  n    CUIDADO   Antes de encender el aparato  quien lo va a usar tiene que controlar si la tensi  n indicada en  el selector de tensi  n corresponde a la tensi  n de la red el  ctrica y que los fusibles instalados  correspondan a la tensi  n seleccionada     4 2 2 INTERRUPTOR MEC  NICO DE LA ALIMENTACI  N     El interruptor mec  nico de la alimentaci  n se emplea para dar paso a la corriente el  ctrica  Para encender  el aparato  pulse el interruptor en la parte derecha  1     Cuando el aparato est   encendido  se ilumina el panel frontal  Al pulsar el interruptor hacia la izquierda   0   se corta la corriente  Esta operaci  n permite utilizar el interruptor mec  nico a guisa de interruptor de  emergencia  si se produce una aver  a     4 3 PANEL FRONTAL                       COAGULO    A        
8.  Servizio di Bioingegneria o di altro personale qualificato     HI Controllo delle condizioni dei cavi e dei connettori di alimentazione   Controllo visivo delle protezioni meccaniche     Controllo delle protezioni contro i pericoli derivanti da versamento di liquidi  sgocciolamento   umidit    penetrazioni di liquidi  pulizia  sterilizzazione e disinfezione     Controllo dei dati sulla targa dell apparecchiatura   Controllo della disponibilt   del libretto di istruzione   Controllo degli attuatori della uscita ad alta frequenza   Misura della resistenza di conduttivit   verso terra   Misura della corrente di dispersione ad alta frequenza   Controllo di stimolazione neuromuscolare     Controllo della accuratezza della potenza di uscita     Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 15    GIMA SpA    DIATERMO 106    TRADUZIONE DEI TERMINI IN LINGUA STRANIERA PRESENTI                                     SULL   APPARECCHIATURA  PANNELLO POSTERIORE  Class Classe di sicurezza elettrica  Duty Cycle Ciclo di funzionamento  Exclusive     Prodotto esclusivamente per  Frequency Frequenza  di lavoro   Fuse Fusibili  Made in Italy Prodotto in Italia  Manufacturer Produttore  Model Modello  Output Coag Uscita Coagulazione  Max su carico di riferimento   Output Cut Uscita Taglio  Massima su carico di riferimento        Serial Number    Numero Seriale          Warning  no              Attenzione  Nessuna parte interna    soggetta a servizio da parte dell
9.  consola  con panel frontal  revestido con una capa de lexan   Altura 100 mm Longitud 180 mm  Profundidad 180 mm Peso 2 8 Kg  Entrada alimentaci  n Seleccionable 115 o 230 V  50 60 Hz  Corriente m  xima 0 5 A  230 V o 1 A  115 V   Toma IEC con fusibles  selector de tensi  n e interruptor incorporados   Indicadores  Indicadores digitales en forma de leds que indican el nivel de salida  con arreglo al siguiente patr  n   CUT 0 50 BLEND 0     45  COAG 0 40    Controles de la potencia de salida mediante dos botones    El uso de botones hace que el usuario pueda controlar con gran precisi  n la potencia de salida  por  cuanto es posible modificar la potencia a trav  s de escalones de un solo vatio    Potencia de salida m  xima          CUT 50 W     10  BLEND 45 W     10   COAG 40 W     10    Resistencia de referencia 400 Q   Tensi  n m  xima en vac  o 900 Vpp     10                 Factor de amplitud  CUT 1 5 BLEND 1 8  COAG 2 5  Frecuencia de salida 600 kHz     10   Frecuencia de modulaci  n CUT Ninguna BLEND 10 kHz  COAG 10 kHz  Tiempo de suministro permitido  Duty Cycle  10 30 segundos  10 segundos de suministro         25 segundos pausa     Manuale d istruzioni   Instruction   s Manual   Manual de Instrucciones MA126IGBEa 35    GIMA SpA DIATERMO 106       6  MANTENIMIENTO       6 1 CARACTER  STICAS GENERALES    El aparato no tiene piezas que haya que regular para su calibraci  n  ni para su funcionamiento    No abra la carcasa del aparato  La garant  a que cubre la unidad pier
10.  della pressione arteriosa   con serie malattie del sistema nervoso   con serie insufficienze renali    in stato di gravidanza   MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA    La stimolazione di muscoli o nervi del paziente pu   essere causata da correnti a bassa frequenza  originate da scintillio elettrico tra gli elettrodi ed il tessuto del paziente  Qualora si verifichi  stimolazione neuromuscolare bloccare l intervento chirurgico e controllare tutte le connessioni  al generatore  Se il problema non viene risolto in questo modo il generatore deve essere  ispezionato da personale qualificato per la manutenzione    L apparecchiatura elettrochirurgica emette radiazioni di energia ad alta frequenza senza  preavviso che pu   influenzare altre apparecchiature mediche  elettronica non relazionata   telecomunicazioni  sistemi di navigazione     2 2 INSTALLAZIONE    La sicurezza elettrica del DIATERMO 106    assicurata soltanto quando lo stesso    connesso  correttamente ad una efficiente rete collegata a terra in conformit   alle attuali norme di sicurezza  E   necessario verificare questo requisito fondamentale di sicurezza e  in caso di dubbio  richiedere un  controllo accurato dell impianto da parte di personale qualificato  Il fabbricante non pu   essere  considerato responsabile per possibili danni causati dalla mancanza di una efficiente connessione a  terra della installazione  L operazione senza connessione 
11.  di effettuare il contatto con il tessuto  Mantenere pulito l elettrodo    Attendere almeno cinque secondi prima di ripetere un colpo   Quando la potenza di uscita    quella giusta dovrebbe ottenersi     MH nessuna resistenza al movimento dell elettrodo attraverso il tessuto  MI nessuna variazione nel colore delle superfici tagliate  MI nessuna fibra di tessuto residuata sull elettrodo     1 4 COAGULAZIONE MONOPOLARE    La coagulazione monopolare    la emostasi di piccoli vasi sanguigni del tessuto corporeo attraverso il  passaggio della corrente ad alta frequenza in corrispondenza all elettrodo attivo    Quando la densit   di corrente    ridotta ed    usato un elettrodo a superficie ampia per dissipare l energia  su un area pi   grande  l effetto    di essiccare la superficie delle cellule  senza penetrazione in profondit     con risultato di coagulazione    Queste superfici cellulari coagulate agiscono come uno strato isolante  che previene il calore dovuto a  successive applicazioni di corrente dal penetrare troppo profondamente  La corrente normalmente usata  per la coagulazione    modulata ed in funzione della percentuale di modulazione    la precisione del taglio   la bont   della emostasi   ed il grado di distruzione del tessuto  Maggiore modulazione della corrente porta a taglio pi   frastagliato  ed a probabile maggiore profondit   di tessuto distrutto ma coagulazione pi   efficace    DIATERMO 106 permette la coagulazione con un alto grado di profondit   di modulazio
12.  la scarica derivante dall uso di defibrillatore    3  Radiazione non ionizzante    4  Leggere attentamente il manuale di istruzioni prima di tentare di usare l apparecchiatura     F 19    i    1  4 2 PANNELLO POSTERIORE          EXCLUSIVELY MANUFACTURED FOR  AGMA ma aTeo  1  20064 Gorg  nzale  MI    MANUFACTURER                                 LED SpA   rrosinone   may    DIATERMO 106  MADE  aow     4002 600KHz   icr   py  OUTPUT CUT FREQUENCY DUTY CYCLE ENSURE THAT THE MAINS IS CORRECT BEFORE CONNECT THE  n CABLE TO THE SOCKET  50W     4002 600KHz  int  10sec  25 sec     ASSICURARSI CHE LA TENSIONE DI RETE SIA CORRETTA PRIMA  SERIAL NUMBER DI COLLEGARE IL CAVO ALLA PRESA DI ALIMENTAZIONE       AVF LET  115 vac   60 Hz 230 Vac   50 Hz  90 VA 90 VA    126  CE A Q  ruse2zx2AT FUSE2x 1 AT  WARNING   NO OPERATOR SERVICEABLE PARTS INSIDE  REFER SERVICING TO QUALIFIED PERSONNEL                                                            1 Presa di alimentazione 2 Interruttore di alimentazione  3 Portafusibili     selettore di tensione    4 2 1 MODULO DI ALIMENTAZIONE DELLA APPARECCHIATURA E SELETTORE DI TENSIONE     Il modulo di alimentazione della apparecchiatura costituisce il punto di connessione della alimentazione per  l elettronica interna della apparecchiatura  Il suddetto modulo di alimentazione incorpora il connettore di  alimentazione ed i fusibili di linea  Il selettore di tensione    posto all interno del modulo di alimentazione     Manuale d   istruzioni   Instructions
13.  repercutir en el funcionamiento de otros aparatos m  dicos  electr  nicos  no relacionados  con el mismo   de telecomunicaciones o de sistemas de navegaci  n     2 2 INSTALACI  N    30    La seguridad el  ctrica de DIATERMO 106 est   supeditada  exclusivamente  a que el mismo se  conecte correctamente con un dispositivo de puesta a tierra eficiente  conforme a lo prescrito en  las normas vigentes en materia de seguridad el  ctrica  Es preciso verificar que se cumpla con  este requisito de seguridad fundamental  En caso de dudas  haga controlar la instalaci  n por  parte de personal cualificado al efecto  El fabricante declina toda responsabilidad  en caso de  da  os que provocare una instalaci  n que carece de una puesta a tierra eficiente  Queda  terminantemente prohibido operar sin la puesta a tierra de protecci  n     Antes de conectar el aparato  verifique si la tensi  n de alimentaci  n requerida  los datos vienen  en el panel trasero  corresponde a la tensi  n de la red     En caso de incompatibilidad  entre la toma y el cable de alimentaci  n del aparato  c  mbielos por  conectores o accesorios aprobados legalmente  No es aconsejable utilizar adaptadores  tomas m  ltiples   ni extensiones  De ser menester utilizarlos  es indispensable que use exclusivamente adaptadores   simples o m  ltiples  o extensiones conformes a las normas vigentes en materia de seguridad     El uso de todo aparato el  ctrico requiere el respeto de algunas reglas fundamentales  En particular   n
14.  with  pure sine wave form is achieved     Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 17    GIMA SpA DIATERMO 106  The following rules help the operator to obtain good cutting  however every user must follow first of all  his professional judgement as he does every time in his practice      Keep the tissues moist but not wet     Survey the stroke before activate the electrode     Keep the electrode perpendicular to the tissue     Activate the electrode before making contact with the tissue     Keep the electrode clean     Wait at least five seconds before to repeat a stroke   When the output power is properly set there should be      no resistance to the electrode movement through the tissue     no change in the cut surfaces color     no fibers of tissue remained onto the electrode    1 4 MONOPOLAR COAGULATION    Monopolar coagulation is the hemostasis of small blood vessel of the bodily tissue through the passing of  high frequency current in correspondence of the active electrode When the current density is reduced and  a broad surfaced electrode is used to dissipate the energy over a larger area  the effect is to dry out the  surface cells  without deep penetration  resulting in coagulation  These coagulate surface cells then serve  as a layer of insulation  preventing heat from successive applications of current from penetrating too  deeply   The current normally used for coagulation is modulated and depending from the modulation perce
15. 07 2005    Attuazione delle Direttive 2002 95 CE e 2003 108 CE  relative  alla riduzione di sostanze pericolose nelle apparecchiature elettriche ed elettroniche  nonch   allo smaltimento dei rifiuti           A fine vita il presente prodotto non deve essere smaltito come rifiuto urbano  lo stesso deve essere oggetto di  una raccolta separata    Se il rifiuto viene smaltito in modo non idoneo    possibile che alcune parti del prodotto  ad esempio eventuali  accumulatori  possono avere effetti potenzialmente negativi per l ambiente e sulla salute umana    Il simbolo a lato  contenitore di spazzatura su ruote barrato  indica che il prodotto non deve essere gettato nei  contenitori per i rifiuti urbani ma deve essere smaltito con una raccolta separata    In caso di smaltimento abusivo di questo prodotto sono previste delle sanzioni        Information about elimination of this product  Applicable in the European Union and other European countries  with separate collection systems        I    O       On the end of the life  the present product mustn t be eliminated as urban refusal  but it must be eliminated in  a separated collection    If the product is eliminated in unsuitable way  it is possible that some parts of the product  for example some  accumulators  could be negative for the environment and for the human health    The symbol on the side  barred dustbin on wheel  denotes that the products mustn t throw into urban refuses  container but it must be eliminated with separat
16. 4 2 2 Power On Off Switch  4 3 FRONT PANEL      4 3 1 User Keys  AES  Di CONMECCOM ia NS                4 MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA  4 3 3 Warning Signals                 24    5  TECHNICAL SPECIFICATIONS          SPE GENERAL cri REI Iii 25  6  PREVENTIVE MAINTENANCE         ccccsssssssscsssccssecssscessecesscsscseessacessceecseessecesesses 20  OIGENERAL  0 KE Aaa ala E  6 2 CLEANING OF THE CABINET n  6 3 CLEANING AND STERILIZATIONOF THE ACCESSORY ITEMS  coccion 26  6 4 CHECKING OF THE EQUIPMENT BEFORE EACH USE    26  6 5 FUNCTION AND SAFETY CHECK AND TEST                     ii 26    3K ok ok k k k k I k k k ok ok k RI E E k k E k k E E E E ER k ok ok ok k E E k k k k ok k k k k    1 1 CONTROL DE LA LISTA DE PARTES  L 2 DESCRIPCION GENERAL   anto a a ues AA AA AA AMA ROIO  1 3 CORTE MONOPOLAR  ici Aaaa   LA COAGULACI  N  MONOPOLAR Ia    2 1 CARACTER  STICAS GENERALES     2 2 INSTALA CI  N      4  CONECTORES Y CONTROLES    eseseseseseeeeeseeeeeecececeeeeeeececeeeeeeeeeeeeeeeeeeeeoeeeeeeeeeesee 32            AL PLACA DEL PANEL TRASERO cio AA A EAE eSEE TEARRE EaR 32  4 1 1 Datos de identificaci  n del Fabricante                 iii 32  4 1 2 Datos TECNICOS          iii    4 1 3 Significado de los S  mbolos GtdficOS                      wwwmommmmmsmmmammmmimimmaimmm mam nima mma 32   BD ERE RAS RO De oe 32    4 2 1 M  dulo de alimentaci  n del aparato y selector de tensi  n  4 2 2 Interruptor me
17. MANUALE D   ISTRUZIONI   INSTRUCTION   S MANUAL    MANUAL DE INSTRUCCIONES    DIATERMO 106       GIMA       GIMA SPA  Via Marconi 1   20060 Gessate  MI    ITALY  Tel  39 02 9538541 Fax  39 02 95381167  www gimaitaly com  gima gimaitaly com   export gimaitaly com  MA126IGBEa    MA126IGBEa Ed 01 2006    DIATERMO 106 GIMA SpA       IMPORTANTE   IMPORTANT   IMPORTANTE       Queste istruzioni operative costituiscono una parte fondamentale dell   apparecchiatura per chirurgia ad  alta frequenza  in quanto ne descrivono il funzionamento e l   uso  pertanto devono essere lette  attentamente prima di iniziare l   installazione e l   uso dell   apparecchiatura    Tutte le istruzioni di sicurezza o note di avvertimento devono essere osservate  Siate certi che queste  istruzioni operative siano fornite insieme all   apparecchiatura quando    trasferita ad altro personale  operativo    Nessuna parte di questo documento pu   essere fotocopiata  riprodotta o tradotta in un altra lingua senza il  consenso scritto della LED SpA    In caso di necessit   di Assistenza Tecnica  contattare il proprio rivenditore     These operating instructions form an integral part of the equipment and must be available to the  operating personnel at all times    All the safety instructions and advice notes are to be observed  Be sure that these operating instructions  is furnished together the equipment when this is transferred to other operating people    No part of this document could be photocopied  reproduc
18. RMO 106 H F Electrosurgical unit is dealered by GIMA SpA Via Marconi  1 I 20060  Gessate  MI   ITALY     4 1 2  TECHNICAL DATA    OUTPUT COAG  40 W     4000 FREQUENCY  600 kHz  OUTPUT CUT  50 W   4000 FREQUENCY  600 kHz  MAIN POWER  115 V    50 60 Hz FUSE 2 x 2 AT  Antisurge    230 V    50 60 Hz FUSE 2 x 1 AT  Antisurge   DUTY CYCLE  intermittent 10 seconds output   25 seconds pause   CLASS  I CF    4 1 3 GRAPHIC SYMBOLS  MEANING     The meaning of the graphic symbols printed on the DIATERMO 106  s cabinet is the following    1  Floating Patient s plate  not connected to the earth neither at low frequency nor at high frequency   2  The equipment is protected against H V  discharge due to the use of a Cardiac Defibrilator    3  Not Ionizing Radiation emitted   4  Read carefully the INSTRUCTION s MANUAL before to attempt the use of the equipment     F  Q C 2     1  4 2 REAR PANEL             E   A GIMA Spe   ViaTrento  10  OUIA MERA    MANUFACTURER MODEL          LEDSPA   rrosinone   maw  DIATERMO 106   QUTPUTCOAG FREQUENCY  CLASS  MADE  aow     4000 600KHz   icr   y  ENSURE THAT THE MAINS IS CORRECT BEFORE CONNECT THE  50W     4002 600 KHz  int  10 sec   25 sec  ea    ASSICURARSI CHE LA TENSIONE DI RETE SIA CORRETTA PRIMA  SERIAL NUMBER DI COLLEGARE IL CAVO ALLA PRESA DI ALIMENTAZIONE      AVF LEN  115 vac   60 Hz 230 Vac   50 Hz  90 VA 90 VA    126  CE A    FUSE2x2AT FUSE2x 1 AT  WARNING   NO OPERATOR SERVICEABLE PARTS INSIDE  REFER SERVICING TO QUALIFIED PERSONNEL           
19. RMO 106 da la possibilit   di effettuare  elettrochirurgia   monopolare minore    L apparecchiatura    prevista per uso da consolle    Sono applicati i circuiti ed i componenti elettronici pi   avanzati  compresi microcontrollori LSI  per  disporre tutti i requisiti per operazioni affidabili e sicure  In questo modo    stato evitato la maggior parte  dei problemi termici e la necessit   di ventole di raffreddamento  molto pericolose per la diffusione di  batteri nelle sale terapeutiche    Il controllo delle unit   avviene attraverso pulsanti ed indicatori posti sul pannello frontale  l ingresso e  l interruttore della rete sono sul pannello posteriore    Il tipo di operazioni chirurgiche che possono essere eseguite sono quelle nelle quali    richiesto il taglio o  la coagulazione monopolare    L uso del DIATERMO 106    riservato a personale medico specializzato  e deve essere usato soltanto per  lo scopo indicato dalla LED S p A    Il DIATERMO 106 comprende le seguenti componenti     BM il generatore  o unit    WE il manipolo   MH glielettrodi   WE 1a placca paziente   BM ilpedale     1 3 TAGLIO MONOPOLARE    Il taglio monopolare    il sezionamento del tessuto biologico ottenuto dal passaggio di corrente ad alta  frequenza ad alta densit   concentrata dalla punta dell elettrodo attivo  Quando la corrente ad alta  frequenza  mediante la punta dell elettrodo attivo     applicata al tessuto  essa crea intenso calore  molecolare nelle cellule tale che la cellula esplode  L effett
20. a alarma puede ayudar a disminuir o prevenir da  os  tanto para el paciente como  para el personal  en caso de que se encienda accidentalmente     MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA       3  INSTALACI  N       E Verifique que el aparato no haya sufrido da  o alguno durante el viaje  Si descubre da  os   notif  queselo de inmediato al transportista    BM Extraiga el aparato del embalaje y estudie atentamente toda la documentaci  n adjunta y las  instrucciones operativas que suministra el fabricante  Sobre la entrada de la alimentaci  n del  aparato est   indicada la tensi  n  la tensi  n de la red el  ctrica tiene que ser igual  frecuencia de  la red  50   60 Hz   La tensi  n correcta se puede ajustar mediante el conmutador giratorio y un  destornillador de punta plana  en el panel trasero  sobre el conector que va a la red    Ml Inserte el fusible adecuado en el m  dulo  con arreglo a lo indicado en la siguiente tabla    E Tensi  n de la red 110   120 V Fusible 2 A T Retardado 5 x 20 mm   E Tensi  n de red 220 240 V Fusible 1 A T Retardado 5 x 20 mm   Para insertar los fusibles  extraiga el portafusibles del m  dulo de alimentaci  n  mediante un  destornillador  fig  A y fig  B   Inserte los fusibles en el portafusibles  fig  C   Vuelva a ubicar el  portafusibles en el m  dulo     A A    A J En    h                                              E Conecte el cable de alimentaci  n con una toma de electri
21. a resistencia a trav  s de la superficie de la Placa del Paciente   Medici  n de la resistencia de conductividad hacia la masa    Medici  n de la corriente de p  rdida de alta frecuencia    Control de estimulaci  n neuromuscular     Control de la precisi  n de la potencia de salida     36 MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA       OUTPUT POWER DIAGRAMS       Diagramma valori a meta potenza   Half power                                                 diagram     CUT0  id             CUTI   gt             CONG  Diagramma valori alla potenza massima   Max  power diagram            CUTO  q           CUTI   gt              COAG  0 4 ARE AA  S      Ss Ss S S  Ohm  Diagramma linearita CUT   CUT linearity   diagram  ss    i  ox RI  an o T  5 3    SO T  Ss f  Sal   53  So                      5 10 20 30 40 45 50    Potenza indicata   Diplay Power  W     Manuale d istruzioni   Instruction   s Manual   Manual de Instrucciones MA126IGBEa 37    GIMA SpA DIATERMO 106    Diagramma linearita BLEND   BLEND  linearity diagram                   SEI  52g   5 481  3      8 307  a 90 t  5 2 18       3     0    5 10 20 30 40 45 50  Potenza indicata   Display power  W   Diagramma linearita COAG   COAG  linearity diagram  2227    5 33t    9 29  q  amp  20    N 5 15   5210   23 5  go 0                   al    10 20 30 40 45 50  Potenza indicata   Display power  W        Informazioni in base all   Art  13 del D Lgs  151 05 del 25 
22. and it is to be used only for the  purposes set down by the manufacturer   DIATERMO 106 consists of the following components      the generator  or unit     the handpiece     the electrodes     the dispersive plate     the pedal switch    1 3 MONOPOLAR CUTTING    Monopolar cutting is the sectioning of the biological tissue caused by the passing of high density  high  frequency current concentrated by the tip of the active electrode  When the high frequency current  by  the tip of the active electrode  is applied to the tissue  it creates intense molecular heat in the cell so that  the cell explodes  The cutting effect is achieved by moving the electrode through the tissue and  destroying the cell one after the other  The movement of the electrode prevents the propagation of the  heat laterally in the tissue  thus limiting the destruction to a single line of cells    The best current for cutting is pure sine wave without any modulation which cuts very smoothly and  provides the least thermal effect with poor hemostasis while cutting  Because its effects can be precisely  controlled  it can be used safely without damage to the bone  but since good coagulation while cutting is  one of principal benefits of using electrosurgery a current with a certain amount of modulation is  desirable     DIATERMO 106 allows cutting with pure sine wave form as well as with two degrees of moderate    modulation producing blend wave form with different crest factor  so more hemostatic effect than
23. any cleaning is undertaken   Clean the outside of the cabinet with a damp cloth  No chemical should be used  a mild non abrasive  cleanser may be used when necessary     6 3 CLEANING AND STERILIZATIONOF THE ACCESSORY ITEMS    The best thing to do is to use only one time use accessories and discard them after use  Since some of the  accessory items are to be used more than once it is mandatory to clean carefully and sterilize those  accessories before the new use  The best way to clean and sterilize the reusable items is to follow the  direction of the supplier of each item  When original reusable accessories supplied by LED S p A  are  applied  the cleaning by using soft cleanser and sterilization through steam sterilization at 134  C is  recommended     6 4 CHECKING OF THE EQUIPMENT BEFORE EACH USE    Each time the use of the electrosurgical equipment is planned a check of the most important safety  aspects has to be implemented considering at least the following      Check the integrity of cords  connections  wire breakage  etc      Assure that all the electrical equipment is properly grounded     Assure that all the accessories that should be used are available and sterilized     6 5 FUNCTION AND SAFETY CHECK AND TEST    At least once a year  the following check and test should be done by the biomedical engineering  department or other qualified personnel      Check of the connectors and mains supply cord conditions      Visual check of the mechanical protections      Chec
24. c  nico de la alimentaci  n          4 3 PANEL FRONTAL issiran 33  4 31 Botones AE USO iii ROIO 33  L ICON A CAOS o ETE TERT dc 34    4 3 3 Se  ales luminosas de advertencia      34  5  CARACTERISTICAS TECNICAS    Dil Caracteristicas  generales ii laica 35    6 1 CARACTER  STICAS GENERALES      36             6 2 LIMPIEZA DE LA CARCASA oocooccococioncnnonnonncnnonos    36  6 3 LIMPIEZA Y ESTERILIZACI  N DE LOS ACCESORIOS    36  6 4 CONTROL DEL APARATO ANTES DE USARLO  u csscsssessesssseeseesseseessesessesseesscsseasessesseseseeseeseeseesesaeeaeeneenes 36    6 5 CONTROL Y MEDIDAS DE FUNCIONES DE SEGURIDAD Qu  sessesssseseeseeeseseeseseeseseeseneeseeeseeeeaeeseaeeneneeneaeeas 36    OUTPUT POWER DIAGRAMS oonconcoconconosnoncsnosconconosocnacnosocnconosocnconosocnconosocaconosocnacno 37    Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 5    GIMA SpA DIATERMO 106       1  INTRODUZIONE       1 1 CONTROLLO LISTA PARTI    Controllare che tutte le parti e accessori ordinati siano stati spediti  in conformita alla seguente lista   Cat  No  GMA10100 05A Unit   DIATERMO 106    Cat  No  00100 03 Cavo di alimentazione lunghezza 2 mt SIEMENS IEC  Cat  No  00404 08 Cavo per connessione dell   elettrodo di riferimento  Cat  No  5365 Elettrodo di riferimento   Cat  No  00301 00 Pedale   Cat  No  00500 03 Kit 6 elettrodi assortiti   Cat  No  MA126IGBE Manuale d   Istruzioni   1 2 DESCRIZIONE GENERALE    L apparecchiatura elettrochirurgica ad alta frequenza DIATE
25. cchiatura  Non eccedere la  temperatura ambiente o l umidit   permessa    BM Condizioni ambientali    E Temperatura  da 10  C a 40   C   Umidit   relativa  da 30  a 75    Pressione atmosferica  da    70 kPa a 106 kPa    MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA       4  CONNETTORI E CONTROLLI       4 1 TARGA SUL PANNELLO POSTERIORE    La normativa per la sicurezza delle apparecchiature chirurgiche ad alta frequenza richiede che alcuni dati  tecnici e simboli grafici siano stampati sull involucro od almeno su uno dei pannelli dell unit   generatore  in modo da definire le sue prestazioni e indicare le sue condizioni di lavoro     4 1 1 DATI IDENTIFICATIVI DEL DISTRIBUTORE    DIATERMO 106 unita elettrochirurgica ad alta frequenza e distribuita GIMA SpA Via Marconi  1  1 20060 Gessate  MI      4 1 2 DATI TECNICI   USCITA TAGLIO CUT   50 W   4000 FREQUENZA  600 kHz   USCITA COAG  COAG   40 W   400 Q FREQUENZA  600 kHz   ALIMENTAZIONE  MAIN POWER  115 V   50 60 Hz FUSIBILI 2x2AT  Ritardati   230 V   50 60 Hz FUSIBILI 2x1AT  Ritardati    DUTY   CYCLE  intermittenti 10 secondi emissione  25 secondi di pausa   CLASSE  ICF    4 1 3 SIGNIFICATO DEI SIMBOLI GRAFICI    Il significato dei simboli grafici stampati sulla targa posta sul pannello posteriore dell apparecchiatura    il seguente   1  Placca paziente fluttuante  non connessa a terra n   alle alte n   alle basse frequenze   2  L apparecchiatura    protetta contro
26. ce it is possible  to vary the  preset output power in step as low as just 1 watt     Max Output Power                    CUT  50 W     10  BLEND  45 W     10   COAG  40 W     10   Reference Load Resistance  4000  No Load Max Voltage  900 Vpp    10   Crest Factor   CUT  1 5 BLEND  1 8  COAG  2 5    Output Frequency  600 kHz     10   Modulation Frequency        CUT  NONE BLEND  10 kHz  COAG  10 kHz   Allowed output time    Duty Cycle  10 seconds output 25 seconds pause    Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones MA126IGBEa 25    GIMA SpA DIATERMO 106       6  PREVENTIVE MAINTENANCE       6 1 GENERAL    No user adjustable parts are within the equipment  either for calibration or service purposes  The  equipment housing must not be opened  the warranty is invalidated by any unauthorized entry into the  unit  In the event any repair or adjustment work being necessary  the whole equipment should be  returned to the LED S p A  Service Centre 04011 APRILIA  LT    ITALY  or to a other Authorized  Centre  together with a description of the fault    Maintenance work by the user is mainly the cleaning of the exterior of the cabinet  cleaning and  sterilization of the accessory items and checking of the equipment before each use  Carrying out function  and safety check for verification of the parameters is demanded to specialized technical people     6 2 CLEANING OF THE CABINET    Switch the equipment off complitely and disconnect the mains supply before 
27. ch  The pedal switch is allowed to control the output current  delivering of the operative condition    2    Monopolar Patient Plate Connector    as   gt   This is the connection point for the Patient Plate  GIO    Handpiece Connector        gt   This is the connection point for the handpiece  GIO    4 3 3 WARNING SIGNALS          Should the unit s inside temperature rise above 75   C i e  the save working level  the digital display  blinks  Stop the output emission until the normal condition is restored     24 MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA       5  TECHNICAL SPECIFICATIONS       5 1 GENERAL    Equipment Description   H F  Electrosurgery Equipment for monopolar minor surgery  The unit provides the facilities to fine  preset the output power level and choose the coagulating effect through the appropriate Crest Factor   Cabinet   Bench top  metal housing  with the frontal and rear panel covered by lexan sheet   Height  100 mm Width  180mm  Depth  180mm Weight  2 8 Kg  Equipment Mains Input  Selectable 115 or 230 V   50 60 Hz   Maximum Current  0 5 A  230V  or 1A  115V   IEC socket with in line fuses  voltage selector and mechanical mains switch   Displays   LED Digital Displays provide the indication of the preset output level as follows   CUT  0 50 BLEND  0 45  COAG  0   40  Output Power Control by two keys  The use of the control keys allows the user to control very accurately the output power sin
28. ciatella  40     1 04011 Aprilia  Provincia de Latina     Italia     4 1 2 DATOS TECNICOS  SALIDA DE CORTE  CUT  50 W   4000 FRECUENCIA  600 kHz  SALIDA COAG  COAG  40 W   4002 FRECUENCIA  600 kHz    ALIMENTACI  N  MAIN POWER  115 V   50 60 Hz FUSIBLES  2x2 AT  Ritardati   230 V   50 60 Hz FUSIBLES  2x1 AT  Ritardati    DUTY   CYCLE  10 25 segundos   CLASE  ICF    4 1 3 SIGNIFICADO DE LOS S  MBOLOS GR  FICOS    El significado de los s  mbolos gr  ficos que se aprecian en la placa del panel trasero del aparato es el  siguiente    1   Placa Paciente fluctuante  no est   conectada con la puesta a tierra ni con altas y bajas frecuencias    2   El aparato est   protegido contra las descargas que puede provocar el uso del desfibrilador    3  Radiaci  n no ionizante    5  Lea atentamente el presente Manual de Instrucciones  antes de usar el aparato por primera vez     F 10    i     1  4 2 PANEL TRASERO       EXCLUSIVELY MANUFACTURED FOR  GIMASp _  Via Trento  10  120064  Garganzole  MI   MANUFACTURER MODEL  LED SPA   rrosinone   maty   DIATERMO 106   OUTPUT COAG   40W     4002 600 KHz    OUTPUT CUT FREQUENCY DUTY CYCLE ENSURE THAT THE MAINS IS CORRECT BEFORE CONNECT THE     CABLE TO THE SOCKET  ASSICURARSI CHE LA TENSIONE DI RETE SIA CORRETTA PRIMA  DI COLLEGARE IL CAVO ALLA PRESA DI ALIMENTAZIONE    115 Vac   60 Hz 230 Vac   50 Hz  90 VA 90 VA                                                                    126          0 0  FUSE2x2AT FUSE2x 1AT  WARNING   NO OPERATOR SERVICEABLE
29. cidad que posea una puesta a tierra  eficiente     QUEDA TERMINANTEMENTE PROHIBIDO USAR EL APARATO SIN PUESTA A TIERRA     HI Ubique el aparato de manera tal que  por detr  s de la boca de ventilaci  n que est   ubicada en la  parte trasera  quede un espacio suficiente como para que pase el aire  La mencionada boca de  ventilaci  n nunca tiene que quedar obstruida  Nada tiene que impedir que el aire circule  libremente     BM Emplee el aparato exclusivamente en ambientes secos  Si se produce condensaci  n de humedad   hay que evaporarla antes de poner en funcionamiento el aparato  La temperatura ambiente y la  humedad no tienen que superar los limites indicados a continuaci  n    Temperatura  de 10  C a40  C Humedad relativa  de 30  a 75   Presi  n atmosf  rica  de 70 kPa a 106 kPa    Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 31    GIMA SpA DIATERMO 106       4  CONECTORES Y CONTROLES       4 1 PLACA DEL PANEL TRASERO    La normativa en materia de seguridad de los aparatos quir  rgicos de alta frecuencia establece que se  impriman unos datos t  cnicos y unos s  mbolos gr  ficos en la carcasa o  en su defecto  en uno de los  paneles de la unidad generadora  con el objeto de definir sus prestaciones e indicar las condiciones de  trabajo     4 1 1 DATOS DE IDENTIFICACI  N DEL FABRICANTE    DIATERMO 106  unidad electroquir  rgica de alta frecuencia  ha sido dise  ada  construida y verificada  por LED SpA  en sus laboratorios sitos en V  a Sel
30. cionar el electrodo   Mantenga el electrodo en una posici  n perpendicular al tejido     a  a  BM Accione el electrodo antes de ponerlo en contacto con el tejido   E Controle que el electrodo permanezca limpio    E    Aguarde cinco segundos  como m  nimo  antes de volver a cortar   Cuando la potencia de salida est   programada correctamente  no se deben percibir     BM ninguna resistencia al movimiento del electrodo  a trav  s del tejido   BM ning  n cambio de color en la superficie cortada     MI ninguna fibra de tejido pegoteada al electrodo     1 4 COAGULACI  N MONOPOLAR    La coagulaci  n monopolar es la hemostasia de peque  os vasos sangu  neos del tejido corporal  que se  obtiene mediante el paso de la corriente de alta frecuencia a la altura del electrodo activo    Cuando la densidad de la corriente es baja y se usa un electrodo de superficie amplia para disipar la  energ  a en un   rea m  s grande  las c  lulas superficiales se secan  sin penetraci  n profunda  ello provoca  el efecto de la coagulaci  n  Luego estas superficies celulares coaguladas act  an como un colch  n  aislante  haciendo que no penetre demasiado a fondo el calor que se produce  cada vez que se aplica la  corriente  La corriente que se usa normalmente para obtener la coagulaci  n est   modulada y la calidad de  la hemostasia y el nivel de destrucci  n del tejido dependen de la modulaci  n y de la precisi  n del corte   Una mayor modulaci  n de la corriente conlleva un corte menos limpio y una mayo
31. compatibility between the available wall socket and the feeding cable of the  equipment  replace only with legally approved connectors and accessory items  The use of  adapters  multiple connections or cable extensions are not advised  Should their use become  necessary it is mandatory to use only simple or multiple adapter conforming to the actual safety  requirements    The use of any electric apparatus involves the observance of some fundamental rules  Particularly   don t touch the apparatus with wet or damp feet or hands    don t use the apparatus with naked feet   don t let the apparatus exposed to atmospheric agents   Don t obstruct openings or cracks of ventilation or heathsink    Don t leave the equipment uselessly inserted  Switch off the equipment when not in use   DIATERMO 106 must be destined only to the use for the which has been expressly designed  Any  other use is to be considered improper and dangerous  The manufacturer can not be considered  responsible for possible damages due to improper  wrong and unreasonable uses    It is dangerous to modify or try modify the characteristic of the equipment    Before effect any operation of cleaning or maintenance  disconnect the apparatus from the electric  net  either unplugging it from the mains or switching off the mains switch of the plant    In case failure and or bad operation of equipment switch off it  For the possible reparation address  only to a authorized service center and ask for the the use of original 
32. de toda eficacia  en caso de manipulaci  n  no autorizada de la misma  De ser necesario reparar o regular el aparato  env  elo completo al Centro de  Asistencia LED SpA APRILIA  Provincia de Latina    Italia y adjunte una descripci  n de la aver  a  El   nico  mantenimiento que ha de efectuar el usuario consiste en la limpieza y la esterilizaci  n de los accesorios y en  controlar el aparato  cada vez que lo tenga que usar  Tan s  lo el personal t  cnico especializado est   autorizado  a efectuar controles funcionales y de seguridad  con el objeto de verificar los par  metros     6 2 LIMPIEZA DE LA CARCASA    Apague el aparato y desench  felo de la red el  ctrica  antes de efectuar las tareas de limpieza  Limpie la  parte exterior de la carcasa con un pa  o h  medo  No use disolventes ni productos qu  micos  Puede  emplear un detergente ligero no abrasivo     6 3 LIMPIEZA Y ESTERILIZACION DE LOS ACCESORIOS    En la medida de lo posible  es aconsejable que use s  lo accesorios desechables y que los elimine despu  s  de usarlos  Sin embargo  dado que hay que usar algunos accesorios m  s de una vez  es imperativo que  limpie con sumo cuidado los accesorios y que los esterilice antes de volverlos a usar  La mejor manera  de limpiar y esterilizar los accesorios que se han de volver a usar consiste en seguir las instrucciones del  proveedor de los mismos  Cuando utilice accesorios que se pueden volver a usar  originales de la casa  LED SpA  le aconsejamos que los limpie usando un d
33. e acumulen en estas partes del cuerpo  antes de usar el aparato  Hay que evaluar  el peligro de ignici  n a partir de gases end  genos    BM Algunos materiales  gasa o algod  n hidr  filo   al saturarse de ox  geno  pueden incendiarse  a  causa de las chispas que emite el aparato durante su uso normal    BM si el paciente es portador de un marcapasos cardiaco o de otros electrodos de estimulaci  n   existe el peligro de que se produzcan interferencias con la se  al del marcapasos  incluso    ste  puede sufrir desperfectos  En caso de dudas  debe Usted pedir consejo al servicio de cardiolog  a    E El uso de la electrocirug  a est   contraindicado  si el paciente     Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 29    GIMA SpA DIATERMO 106    se ve aquejado por graves desequilibrios de la tensi  n arterial    se ve aquejado por enfermedades graves del sistema nervioso    se ve aquejado por una insuficiencia renal grave    es una mujer encinta    La estimulaci  n de m  sculos y nervios del paciente puede deberse a corrientes de baja  frecuencia  provocadas por chispas el  ctricas entre los electrodos y el tejido del paciente  Si se  produce estimulaci  n neuromuscular  detenga la intervenci  n y controle todas las conexiones    del generador  Si el problema persiste  haga que personal de mantenimiento cualificado  inspeccione el generador    El equipo electroquir  rgico emite radiaciones de energ  a de alta frecuencia  sin preaviso  Ello  puede
34. e collection    In case of abusive elimination of this product  could be foreseen sanctions        Informaci  n sobre la eliminaci  n de este producto  Aplicable en le Uni  n Europea y en pa  ses europeos con  sistemas de recogida selectiva de residuos                 En el final de la vida  el actual producto no se debe eliminar como denegaci  n urbana  sino que debe ser  eliminado en una colecci  n separada    Si el producto se elimina de manera inadecuada  es posible que algunas partes del producto  por ejemplo  algunos acumuladores  podr  an ser negativas para el ambiente y para la salud humana    Este s  mbolo indica que el presente producto no puede ser tratado como residuos dom  sticos normales  sino  que deben entregarse en el correspondiente punto de recogida de equipos el  ctricos y electr  nicos    En caso de que de eliminaci  n abusiva de este producto  podr  an estar las sanciones previstas        MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones       
35. e l apparato  dalla rete elettrica  togliendo la spina dalla rete o spegnendo l interruttore generale dell impianto     In caso di rottura o malfunzionamento della apparecchiatura spegnerla  Per la possibile  riparazione riferirsi soltanto a centro di servizio autorizzato e richiedere l uso di parti di  ricambio originali  La mancanza di seguire le suddette norme pu   rischiare la sicurezza della  apparecchiatura e pu   essere pericoloso per l utilizzatore    Non lasciare mai il manipolo drappeggiare sul paziente  Quando non    usato porlo nella vaschetta  portastrumenti  L attivazione casuale pu   causare ustioni al paziente sotto la lama dell elettrodo attivo   Non ridurre o eliminare il segnale acustico di segnalazione della attivazione del generatore  Un    segnale di attivazione funzionante pu   minimizzare o prevenire lesioni a paziente o al personale  in caso di attivazione accidentale     2 3 STANDARD DI SICUREZZA APPLICABILI    DIATERMO 106    conforme alle norme di sicurezza IEC 601 1   EN 60601 1  Apparecchiature  elettromedicali   Norme generali di sicurezza   e IEC 601 2 2   EN 60601 2 2  Apparecchiature  elettromedicali   Norme particolari per la sicurezza delle apparecchiature chirurgiche ad alta frequenza      Manuale d   istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 9    GIMA SpA DIATERMO 106       3  INSTALLAZIONE                                                    MI ispezionare l apparecchiatura per eventuali danni durante il viaggio
36. e qualora l unit   elettrochirurgica fallisca nel produrre  l effetto desiderato  La ragione per un livello di potenza di uscita basso  o per un funzionamento  non corretto dell unit   eletrochirurgica quando predisposta per erogazione normale  pu   essere  una mancata connessione della placca paziente o il suo posizionamento imperfetto     L uso di anastetici infiammabili  di ossigeno e di protossido di azoto dovrebbe essere evitato in  caso di operazione a livello della testa o del busto a meno di non avere possibilit   di evacuare i gas     Materiali infiammabili usati per pulire  o disinfettare  dovrebbero essere lasciati evaporare  prima di usare l unit   elettrochirurgica     C    rischio di stagnazione di soluzioni infiammabili sotto il paziente o nelle cavit   quali  ombelico o vagina  Il fluido che si deposita in queste aree dovrebbe essere rimosso prima di  usare l apparecchiatura  Occorre considerare il pericolo di ignizione di gas endogeni     Alcuni materiali quali garza o cotone idrofilo  quando saturati con ossigeno  possono  infiammarsi a causa delle scintille prodotte dalla apparecchiatura nell uso normale     Vi    un rischio per il paziente impiantato con pace maker cardiaco  o altro elettrodo di  stimolazione  pu   avvenire una interferenza con il segnale dello stimolatore e lo stesso  stimolatore pu   essere danneggiato  Riferirsi al reparto cardiologico in caso di dubbio     L uso della elettrochirurgia non    consigliato in pazienti   con seri squilibri
37. ecto de corte se obtiene  moviendo el electrodo a trav  s del tejido y destruyendo las c  lulas una tras otra  El movimiento del  electrodo evita que el calor se propague por el tejido en sentido lateral  circunscribiendo la destrucci  n a  una   nica l  nea de c  lulas    La mejor corriente para efectuar la incisi  n es la sinusoidal pura  sin modulaci  n alguna  pues la misma  corta con una gran precisi  n y produce un efecto t  rmico m  nimo  con escasa hemostasia mientras corta   Dado que sus efectos se pueden controlar con exactitud  se puede emplear con seguridad sin menoscabar  el hueso  Sin embargo  puesto que una buena coagulaci  n  durante la incisi  n  es una de las ventajas    Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 27    GIMA SpA DIATERMO 106  principales que ofrece la electrocirug  a  es preferible usar una corriente de alta frecuencia con cierto nivel  de modulaci  n    DIATERMO 106 permite cortar con una onda sinusoidal pura o con un grado de modulaci  n moderada   lo cual produce una onda mezclada con diferentes factores de amplitud  Ello permite obtener un efecto  hemost  tico mayor que con una onda sinusoidal pura    Las siguientes reglas se proponen ayudar al cirujano a obtener una buena incisi  n  De todas maneras   cada usuario debe basarse sobre su propio criterio profesional  como cada vez que ejerce la profesi  n     E Mantenga el tejido h  medo  pero no excesivamente   Ensaye el movimiento de corte  antes de ac
38. ector  3 Key for output power increase 8 Patient Plate connector  4 CUT 1 key 9 Foot switch connector    5 BLEND key  4 3 1 USER KEYS    The keys are split into two groups  the four operative keys  positioned at the left of the unit  and the two  output power control keys under the digital display   The two output power control keys are used to increase     or decrease     the output current   The function of each of the operative keys is as follows   9  CUT  TAGLIO    Pressing this key Cut current  i  e  pure sine current is preset  to be delivered when the foot switch output  control is activated  Crest factor of the Cut current is 1 5  Cut current preset condition is indicated by    green LED which will illuminate   9    BLEND    MIX    Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 23    GIMA SpA DIATERMO 106  Pressing this key Blend current  i e  modulated current is preset  to be delivered when the foot switch  output control is activated  Crest factor of the Blend current is 1 8  Blend current preset condition is    indicated by green LED which will illuminate         COAG    COAGULO  Pressing this key presets Coag current  i e  modulated current is preset  to be delivered when the foot   switch output control is activated  Crest factor of the monopolar Coag current is 2 5  Coag current preset  condition is indicated by green LED which will illuminate     4 3 2 CONNECTOR    Pedal Connector  This is the connection point for the foot swit
39. ed or translated in other language without the  written consent of LED SpA    In case of necessity of technical assistance contact your own retailer     Las presentes instrucciones operativas forman parte indisoluble del equipo y han de estar a disposici  n  del personal que lo utiliza  en todo momento    Todas las instrucciones de seguridad y las notas de advertencia se han de cumplir al pie de la letra   Cerci  rese de que estas instrucciones operativas se adjunten al aparato  si el mismo es utilizado por otros  miembros del personal operativo    Queda terminantemente prohibida la reproducci  n del presente Manual  mediante fotocopia u otros  medios  as   como su traducci  n a otros idiomas  sin la autorizaci  n previa y por escrito    De necesitar asistencia t  cnica  contacte a su revendedor                             Produttore   Manufacturer    LED SpA    PROGETTAZIONI E PRODUZIONI ELETTRONICHE  Via Selciatella  40 04010 APRILIA  LT  ITALIA    Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 3    GIMA SpA DIATERMO 106       INDICE   INDEX       IMPORTANTE   IMPORTANT   IMPORTANTE      sssssssesssssssessssesversesessarsesecversesesnees  1  INTRODUZIONE              1 1 CONTROLLO LISTA PARTI    1 2 DESCRIZIONE GENERALE  1 3 TAGLIO MONOPOLARE   1 4 COAGULAZIONE MONOPOLARE    QD GENERALE cialis Msisi mimea hi ci AIA EIA RI A  2 2 INSTALLAZIONE  2 3 STANDARD DI SICUREZZA APPLICABILI    4  CONNETTORI E CONTROLLL              s sesesesesesesesos
40. etergente ligero  en una cuba de ultrasonido y  esterilizaci  n a vapor a una temperatura de 123   C  durante 45 minutos     6 4 CONTROL DEL APARATO ANTES DE USARLO  Cada vez que tenga que usar el aparato  primeramente  verifique el cumplimiento de las principales  condiciones de seguridad  tomando en consideraci  n  como m  nimo  las que indicamos a continuaci  n     E Controle que los cables  los conectores y el aislamiento de los cables est  n en perfectas  condiciones     HM Cerci  rese de que el aparato est   conectado con la puesta a tierra  como es debido   BM Constate que todos los accesorios que va a usar est  n esterilizados y a su disposici  n     6 5 CONTROL Y MEDIDAS DE FUNCIONES DE SEGURIDAD    Peri  dicamente  como m  nimo  una vez por a  o  el aparato tiene que ser sometido a controles y  mediciones por parte del Servicio de Bioingenier  a o de otro personal cualificado     Control del estado de los cables y de los conectores de alimentaci  n   Control visual de los elementos mec  nicos de protecci  n     Control de los dispositivos de protecci  n contra los peligros que provocan los l  quidos al  derramarse  el goteo  la humedad  la penetraci  n de l  quidos  la esterilizaci  n y la desinfecci  n     Control de los datos de la placa del aparato  Constatar que el Manual de Instrucciones est   disponible   Control de circuito de vigilancia de la Placa del Paciente    Control de los accionamientos de la salida de alta frecuencia    Control de la uniformidad de l
41. ever the electrosurgical unit fails to produce the desired  effect  Reason for a low output power level  or for an uncorrect functioning of the electrosurgical  unit when arranged for a normal output  may be lack of connection of the dispersive plate or its  imperfect placement      The use of flammable anesthetics  of oxygen and of nitrogen protoxyde should be avoid in the case  of operation at the head or at chest level except the possibility of evacuating gas      Flammable materials used to clean  or to disinfect  should be let to evaporate before the use of the  electrosurgical unit      There is risk of stagnation of flammable solutions under the patient or in body cavities as the  umbilicus and the vagina  The fluid which deposits in these areas should be removed before the  equipment use  The danger of endogenous gas ignition has to be considered      Some materials like cotton wool or gauze  when saturated with oxygen  may burst into flames  because of the sparks produced by the equipment in the normal use      There is a risk for the patients fitted with heart pace maker  or other stimulation electrode  an  interference may occur with the stimulator signal or the stimulator itself can be damaged  Please  refer to the cardiologic department when in doubt      The use of electrosurgery is not recommended in patients      with serious unbalance of arterial pressure     with serious illness of the nervous system     with serious renal insufficiencies     in state of pre
42. gnancy     Inadvertent stimulation of a patient s muscle and nerves can be caused by low frequency currents  originating in electric sparks between the electrode and the tissue of the patient  Should  neuromuscular stimulation occur stop the surgery and check all the connections to the generator  If  this does not solve the problem the generator must be inspected by qualified service personnel    Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones MA126IGBEa 19    GIMA SpA DIATERMO 106    The electrosurgical equipment does emit unnoticed radiation of high frequency energy that may  effect other medical equipments  unrelated electronics  telecommunications  navigational systems     2 2 INSTALLATION    The electric safety of DIATERMO 106 is insured only when the same is correctly connected to an  efficient net linked to the earth in conformity with the actual safety requirements  It is neccessary  to verify this fundamental safety requisite and  in case of doubt  to require an accurate control of  the plant from part of qualified personnel  The manufacturer cannot be considered responsible for  possible damages caused from the lack of efficient connection to earth of the installation   Operation without a protective earth connection is forbidden    Before connect the equipment ascertain that the required voltage  showed on the rear panel   corresponds to the available mains  The fuse holder is installed on the mains input connector  module    In case of in
43. ias  electromagn  ticas  se han de ubicar lo m  s lejos posible de los electrodos de la unidad quir  rgica     HM No utilice agujas de monitoreo     E Los cables de enlace que van hasta los electrodos del electrobistur   se tienen que ubicar de  manera tal que no toquen al paciente  ni otros cables  De operarse zonas del cuerpo  cuya  secci  n es relativamente peque  a  para evitar que se produzca una coagulaci  n indebida  es  aconsejable utilizar la t  cnica bipolar     MI El nivel de la potencia debe estar lo m  s bajo posible  en lo que cabe  en funci  n del trabajo a realizar     E Controle siempre la placa paciente  si la unidad quir  rgica no produce el efecto deseado  La  raz  n puede estribar en un nivel de potencia de salida bajo  Tambi  n puede suceder que la  unidad electroquir  rgica no funcione correctamente porque  si bien est   preparada para un  suministro normal  la placa no est   conectada o su posicionamiento es imperfecto    E No hay que usar anestesia inflamable  ox  geno  ni prot  xido de nitr  geno  cuando se opera la  cabeza o el t  rax  excepto si existe la posibilidad de aspirarlos    M Hay que dejar que se evaporen los materiales inflamables  que se emplean para hacer la  limpieza o para desinfectar  antes de usar la unidad electroquir  rgica    MH Hay que impedir que se estanquen las soluciones inflamables por debajo del paciente y en las  cavidades del cuerpo humano  por ejemplo  en el ombligo o en la vagina  Hay que eliminar los  l  quidos que s
44. ibile variare la potenza predeterminata in gradini di un solo watt    Massima potenza di uscita                    CUT  50 W     10  BLEND  45 W     10   COAG  40 W     10    Resistenza di riferimento 4000   Tensione massima a vuoto  900Vpp     10    Fattore di cresta   CUT  1 5 BLEND  1 8  COAG  2 5   Frequenza di uscita  600 kHz     10    Frequenza di modulazione   CUT  Nessuna BLEND  10 kHz  COAG  10 kHz    Tempo di erogazione permesso        Duty Cycle     14 MA 126IGBEa    10 secondi erogazione   25 secondi pausa    Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA       6  MANUTENZIONE       6 1 GENERALITA    Non ci sono all interno della apparecchiatura parti regolabili dall   utente per calibrazione o di servizio   L involucro dell apparecchiatura non deve essere aperto  la garanzia     invalidata da qualsiasi  manomissione non autorizzata dell unit    In caso di necessit   di riparazione o regolazione  l intera  apparecchiatura dovrebbe essere tornata al centro di servizio LED SpA APRILIA  LT  ITALY  insieme  ad una descrizione del guasto    La manutenzione da parte dell utilizzatore consiste principalmente nella pulizia e sterilizzazione degli  accessori e nel controllo dell apparecchiatura prima di ciascun uso  L esecuzione di controlli funzionali e  di sicurezza per la verifica dei parametri    demandata a personale tecnico specializzato     6 2 PULIZIA DEL CONTENITORE    Spengere completamente l apparecchiatura e d
45. isconnettere la rete prima di qualsiasi pulizia  Pulire  l esterno del contenitore con un panno umido  Non usare alcun componente solvente o chimico  un  detersivo leggero e non abrasivo pu   essere usato     6 3 PULIZIA E STERILIZZAZIONE DEGLI ACCESSORI    Per quel che    possibile    consigliato utilizzare soltanto accessori monouso ed eliminarli dopo l uso   Tuttavia poich   alcuni accessori devono essere usati pi   di una volta    imperativo pulire con cura e  sterilizzare quegli accessori prima del nuovo uso  Il migliore modo di pulire e sterilizzare gli accessori    riusabili    quello di seguire le istruzioni del fornitore di ciascun elemento  Quando sono applicati    accessori riusabili originali forniti dalla LED     raccomandata la pulizia usando detersivo leggero e  sterilizzazione a vapore a 123   C per il tempo di 45 minuti     6 4 CONTROLLO DELL APPARECCHIATURA PRIMA DELL USO    Ogni volta che si programma l uso dell apparecchiatura occorre implementare un controllo delle  principali condizioni di sicurezza considerando almeno le seguenti     MH Controllare l integrit   dei cavi  connessioni  eventuali danni all isolamento dei cavi stessi   BM Assicurarsi che l apparecchiatura sia messa a terra appropriatamente   BM Assicurarsi che tutti gli accessori che dovranno essere usati siano disponibili e sterilizzati     6 5 CONTROLLO E MISURA DI FUNZIONI DI SICUREZZA    Periodicamente  almeno una volta l anno  dovrebbero essere eseguiti controlli e misure da parte del 
46. k of the protections against the danger due to liquid s pouring  dripping  moisture  liquid s   penetration  cleanliness  sterilization and disinfection      Check of the Equipment s Datas on the Label     Check of the availability of the Instruction s Manual     Check the functioning of the H F  output controls     Check the uniformity of the resistance through the surface of the patient plate      Test the earth conductivity resistance      Test the earth leakage current  Test H F  leakage current      Control of the neuromuscular stimulation  Control of the accuracy of the output power     26 MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA       1  INTRODUCCI  N       1 1 CONTROL DE LA LISTA DE PARTES    Cerci  rese de que todas las partes y accesorios que ha encargado hayan llegado a sus manos  de  conformidad con la siguiente lista     REF GMA10100 05A Unita DIATERMO 106   REF 00301 00 Pedal   REF 00100 03 Cable de alim  Largo 2 mt SIEM IEC  REF 00500 03 Kit de 6 electrodos surtidos   REF 00404 08 Cable de conex  placa paciente   REF 5365 Placa del paciente   REF MA126IGBE Manual de Instrucciones   1 2 DESCRIPCION GENERAL    El electrobistur   de alta frecuencia DIATERMO 106 ofrece la posibilidad de efectuar intervenciones de  electrocirug  a monopolar menor    El instrumento ha sido ideado para su uso desde consola    Consta de los circuitos y los componentes electr  nicos m  s avanzados  e incluso viene con 
47. los  microcontroladores LSI  a fin de satisfacer todos los requisitos que permiten realizar operaciones fiables  y seguras    De esta forma  se ha evitado la mayor  a de los problemas t  rmicos y el uso de ventiladores de  enfriamiento  muy peligrosos  pues propagan las bacterias en las salas terap  uticas    El control de las unidades se realiza mediante botones e indicadores que est  n ubicados en el panel  frontal  La entrada y el interruptor de la red se hallan en el panel trasero    El aparato no ha sido proyectado espec  ficamente para corregir anomal  as cardiacas  ni del sistema  circulatorio central a trav  s del contacto directo con dichas partes del cuerpo    El tipo de intervenciones quir  rgicas que se pueden efectuar son las que requieren el corte y la  coagulaci  n monopolar    El uso de DIATERMO 106 ha de estar a cargo exclusivamente del personal m  dico especializado  y ha  de respetar los objetivos indicados por LED S p A    DIATERMO 106 consta de los siguientes componentes     Mel generador o unidad  Mel mango   BM los electrodos   WE 1a placa del paciente  E el pedal     1 3 CORTE MONOPOLAR    El corte monopolar es la incisi  n del tejido biol  gico que provoca la corriente de alta densidad y de alta  frecuencia concentrada  al pasar por la punta del electrodo activo    Cuando la corriente de alta frecuencia  que pasa por la punta del electrodo activo  se aplica al tejido  crea  en la c  lula un calor molecular tan intenso que hace que   sta estalle  El ef
48. ne e un alto  fattore di cresta in modo da ottenere maggiore effetto termico  e conseguente effetto emostatico  di  quello ottenuto con corrente sinusoidale pura    Le seguenti regole aiutano l operatore ad ottenere buona coagulazione  naturalmente ciascun utilizzatore  deve seguire prima di tutto il proprio giudizio professionale come fa sempre nella sua pratica     MI selezionare un elettrodo a pallina o un filo spesso    BM localizzare il vaso sanguinante dopo aver asciugato il sangue in eccesso dall area  toccare  leggermente il vaso sanguinante prima di attivare l elettrodo    MI cessare l attivazione dell elettrodo appena il tessuto si sbianca per evitare di danneggiarlo     Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 7    GIMA SpA DIATERMO 106       2  SICUREZZA       AVVERTENZA Queste istruzioni operative costituiscono una parte integrale della apparecchiatura e  devono essere disponibili al personale operativo in ogni momento  Tutte le istruzioni di sicurezza o note di  avvertimento devono essere osservate  Siate certi che queste istruzioni operative siano fornite insieme alla  apparecchiatura quando    trasferita ad altro personale operativo  L elettrochirurgia pu   essere pericolosa   l uso non accurato di ogni elemento del sistema elettrochirurgico pu   sottoporre il paziente a serie ustioni   Leggere e comprendere tutti gli avvertimenti  le precauzioni e le indicazioni per l uso prima di tentare di  usare qualsiasi elettrodo at
49. ntage  is the smoothness of cutting  goodness of hemostasis and likelihood of tissue destruction  Deeper current  modulation brings to somewhat roughly cutting and the chance of some slight depth of tissue destruction  but more efficient coagulation   DIATERMO 106 allows coagulation with deep modulation producing blend wave form with high crest   factor so more thermal effect and consequently hemostatic effect than with pure sine current has  achieved   The following rules help the operator to obtain good coagulation  however every user must follow first  of all his professional judgement as he does every time in his practice      Select a ball or heavy wire electrode     Locate the bleeder  after have wiped the excess blood from the area  contact lightly the bleeder   before activating the electrode    Stop the electrode activation as soon as the tissue blanches to avoid tissue damage     18 MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA       2  SAFETY       WARNING These operating instructions form an integral part of the equipment and must be available to  the operating personnel at all times  All the safety instructions and advice notes are to be observed  Be  sure that these operating instructions is furnished together the equipment when this is transferred to  other operating people    Electrosurgery can be dangerous  Careless use of any element in the electrosurgical system may subject  the patient to a se
50. nti surge  Type 5 x 20 mm   Mains Voltage 220 240 V Fuse 2 x 1AT  Anti surge  Type5 x 20 mm  To insert the fuses pull out the fuse holder from the mains module with the help of a screwdriver   Fig 1 and Fig  2    clip the fuses into the holder  Fig  3    replace the holder into the module     B gs                                                 Connect the mains cable to a mains outlet that has good earth connection     OPERATION OF THE EQUIPMENT WITHOUT EARTH CONNECTION IS FORBIDDEN    Position the equipment such that there is sufficient room around it  Air circulation must not be  restricted in any way    Operate the equipment only in dry surroundings  Any condensation that occurs must be allowed to  evaporate before putting the equipment into operation  Do not exceed the permissible ambient  temperature or humidity    Environmental conditions    Temperature  from 10  C up to 40   C   Relative moisture  from 30  up to 75    Atmospheric pressure  from 70 kPa up to 106 kPa  10 PSI up to 15 PSI     Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones MA126IGBEa 21    GIMA SpA DIATERMO 106    4  CONNECTORS AND CONTROLS          4 1 LABEL ON THE REAR PANEL    The requirements for the safety of H F  surgical equipment ask that some technical data and graphic  symbols must be printed on the cabinet or on at least one of the panels of the generator unit to define its  features and oversee its condition of work     4 1 1 DEALER S IDENTIFICATION DATA    The DIATE
51. o di taglio    ottenuto muovendo l elettrodo  attraverso il tessuto e distruggendo le cellule una dopo l altra  Il movimento dell elettrodo previene la  propagazione del calore laterale nel tessuto  limitando cos   la distruzione ad una singola linea di cellule   La migliore corrente per il taglio    la sinusoidale pura senza alcuna modulazione  questa  infatti  taglia  con molta precisione e produce il minimo effetto termico con scarsa emostasi mentre taglia  Poich   il suo  effetto pu   essere controllato con precisione  pu   essere usata in sicurezza senza danno per l osso ma   poich   una buona coagulazione durante il taglio    uno dei principali benefici dell uso della  elettrochirurgia     desiderabile una corrente con una certa quantit   di modulazione    DIATERMO 106 permette il taglio con onda sinusoidale pura o con un grado di moderata modulazione  che produce onda miscelata con differente fattore di cresta  in modo da ottenere pi   effetto emostatico  che con onda sinusoidale pura     6 MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA  Le regole seguenti aiutano l operatore ad ottenere un buon taglio  naturalmente ciascun utilizzatore deve  seguire prima di tutto il proprio giudizio professionale come in ogni momento nella sua pratica     Mantenere il tessuto umido ma non bagnato   Provare il colpo prima di attivare l elettrodo   Mantenere l elettrodo perpendicolare al tessuto   Attivare l elettrodo prima
52. o toque el aparato con las manos ni los pies mojados o h  medos    no use el aparato descalzo    no deje el aparato a la intemperie  lluvia  sol  etc      No obture las aberturas o fisuras de ventilaci  n  ni los radiadores    No deje el aparato encendido in  tilmente  Cuando no lo usa  ap  guelo     DIATERMO 106 debe destinarse tan s  lo al uso para el que fue dise  ado especialmente   Cualesquiera otros usos se consideran indebidos y  por lo tanto  peligrosos  El fabricante declina toda  responsabilidad por los da  os que provocare el uso indebido  err  neo y no razonable del aparato     Es peligroso modificar o tratar de modificar las caracter  sticas de la unidad suministrada   Antes de efectuar las tareas de limpieza o mantenimiento  desconecte el aparato de la red  el  ctrica  desenchuf  ndolo o apagando el interruptor general de la instalaci  n     Si el aparato se rompe o no funciona como es debido  ap  guelo  En caso de reparaciones  dir  jase  exclusivamente a un centro de asistencia t  cnica autorizado  Exija que usen repuestos originales  El  incumplimiento de las reglas susodichas menoscaba la seguridad del aparato y del usuario    Nuca deje el mango apoyado en el paciente  Ub  quelo en la bandeja portainstrumental  cuando  no lo usa  Su activaci  n accidental puede provocar quemaduras en el cuerpo del paciente que  queda bajo la cuchilla del electrodo activo     No desconecte la alarma ac  stica del generador  ni baje el volumen de la misma  El poder  escuchar l
53. osososesosososososososososososososososesese LI    4 1 TARGA SUL PANNELLO POSTERIORE     4 1 1 Dati Identificativi del Distributore  4 1 2 Dati Tecnici             ii  4 1 3 Significato dei Simboli Grafici   4 2 PANNELLO POSTERIORE  4 2 1 Modulo di Alimentazione della Apparecchiatura e Selettore di Tensione              4 2 2 Interruttore di Alimentazione    4 3 PANNELLO FRONTALE  4 3 1 Pulsanti d uso             4 3 2 Connettori  4 3 3 Indicatori di avvertimento                                   SA GENERAL  A AIAR AT ITALA TI eee EI Eaa 14    6 1 GENERALIT    6 2 PULIZIA DEL CONTENITORE  6 3 PULIZIA E STERILIZZAZIONE DEGLI ACCESSORI  6 4 CONTROLLO DELL APPARECCHIATURA PRIMA DELL USO  6 5 CONTROLLO E MISURA DI FUNZIONI DI SICUREZZA      3k ok ale ale ok ale ok oe ale ok ale ale ok ale ok ok ale ok ale ale ok ale ok oe ale ok ale ale oe ale ok ok ale ok ale ale fe ale ok ok ale ok ale ok ok ok k    1 1 CHECK LIST       1 2 GENERAL DESCRIPTION  1 3 MONOPOLAR CUTTING                               1 4    MONOPOLAR COAGULATION siii A iia 18  2D  SAFETY isa 19   2 1 GENERAL            2 2 INSTALLATION       2 3 APPLICABLE SAFETY STANDARDS    20  3  INSTALLATION         cccccssecssseeees    4  CONNECTORS AND CONTROLS             s sssesesesesososososososososososososososososososes0s0s000 22  4 1 LABEL ON THE REAR PANEL  4 1 1 Dealer s Identification Data  4 1 2  Technical Data  4 1 3 Graphic Symbols  Meaning     4 2 REAR PANEL  4 2 1 Equipment Mains Input Module and Voltage Selector  
54. protettiva a terra    proibita     Prima di connettere l apparecchiatura accertarsi che la tensione richiesta  indicata sul pannello  posteriore  corrisponda alla rete disponibile     In caso di incompatibilit   tra la presa di corrente disponibile ed il cavo di alimentazione della  apparecchiatura  sostituire soltanto con connettori o accessori legalmente approvati  L uso di adattatori   connessioni multiple o cavi di estensione non    consigliabile  Qualora il loro uso fosse necessario     obbligatorio usare soltanto adattatori singoli o multipli conformi alle attuali norme di sicurezza     L uso di qualsiasi apparato elettrico richiede l osservanza di alcune regole fondamentali  In  particolare    non toccare l apparato con mani o piedi umidi o bagnati   non usare l apparato a piedi nudi   non lasciare l apparato esposto agli agenti atmosferici  pioggia  sole  etc      Non ostruire aperture o fessure di ventilazione o radiatori    Non lasciare l apparecchiatura inserita inutilmente  Spegnerla quando non in uso     DIATERMO 106 deve essere destinato soltanto all uso per il quale    stato appositamente  progettate  Ogni altro uso deve essere considerato improprio e pericoloso  Il fabbricante non pu    essere considerato responsabile per possibili danni dovuti ad improprio  errato o irragionevole uso     E  pericoloso modificare o tentare di modificare le caratteristiche della apparecchiatura     Prima di effettuare qualsiasi operazione di pulizia o manutenzione  disconnetter
55. r profundidad de  destrucci  n del tejido  pero la coagulaci  n es m  s eficaz    DIATERMO 106 permite obtener la coagulaci  n con un elevado grado de profundidad de modulaci  n  y con un elevado factor de amplitud  con el objeto de conseguir un efecto t  rmico  y su consiguiente  efecto hemost  tico  mayor del que se obtiene con una corriente sinusoidal pura    Siguiendo las reglas que se detallan a continuaci  n  el cirujano podr   obtener una buena coagulaci  n  sea  como sea  cada usuario debe basarse en su propio criterio profesional  como hace normalmente en su  vida profesional     E seleccione un electrodo con forma de bola o de filo grueso     Localice el vaso que sangra     a   HM Seque la sangre que mana excesivamente en el   rea y  luego  toque ligeramente el vaso que  sangra antes de accionar el electrodo    a    Desconecte el electrodo  en cuanto el tejido se aclara  para evitar lesiones en el tejido     28 MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA       2  SEGURIDAD       Las presentes instrucciones operativas forman parte indisoluble del equipo y han de estar a disposici  n  del personal que lo utiliza  en todo momento  Todas las instrucciones de seguridad y las notas de  advertencia se han de cumplir al pie de la letra  Cerci  rese de que estas instrucciones operativas se  adjunten al aparato  si el mismo es utilizado por otros miembros del personal operativo  La  electrocirug  a puede consti
56. rious burn  Read and understand all warnings  precautions  and directions for use  before attempt to use any active electrode  Neither LED S p A   Frosinone  Italy nor any of the subsidiary  sales organisations can be considered responsible for personal  material or consequential injury  loss or  damage that results from improper use of the equipment and accessories     2 1 GENERAL      Persons fitted with a heart pacemaker must not operate the equipment nor approach the same while  itis in operation      The patient does not must be in contact with metal parts that are connected to the earth or have a  large electrical coupling capacity to the earth  for example  operating table or metallic support    The use of antistatic sheets is advised      Avoid the skin to skin contact  for example between arm and body of the patient   Insert an  interface material like dry surgical gauze      When high frequency electrosurgical unit and phisiological monitoring devices are used at a time  in the same patient  all the monitoring electrodes  that has not resistive or inductive elements  suitable to high frequency interferencies  must be as far as possible from the electrodes of the  electrosurgical unit      Avoid the use of monitoring needles      The connection to the electrodes should be located in such a way to avoid the contact both with the  patient and with other cables      The power level should be the lowest useful to the work to do      Always check the dispersive plate when
57. spare parts  The lack to follow  the above requirements could risk the safety of the equipment and can be dangerous for the user   Never lay the pen on the patient drape  Set it on the instrument tray when not in use  Accidental  activation can cause patient burns beneath the blade of the active electrode    Do not reduce or disable the audible signal warning the activation of the generator  A functioning  activation signal can minimize or prevent patient or staff injiury in the event of accidental  activation     2 3 APPLICABLE SAFETY STANDARDS    DIATERMO 106 conforms to the safety requirements of IEC 601 1  EN 60601 1  Medical electrical  equipment General requirements for safety   and of IEC 601 2 2   EN 60601 2 2  Medical electrical  equipment   Particular requirements for the safety of high frequency surgical equipment      20    MA126IGBEa Manuale d   istruzioni   Instruction   s Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA       3  INSTALLATION       Inspect the equipment for damage during transit  Any damage should be reported to the carrier  immediately   Unpack the equipment and carefully study the documentation and operating instruction supplied   The mains input voltage  indicated up the equipment mains input  must agree with the local mains  voltage  mains frequency  50 60 Hz   The correct voltage setting is selected as shown in fig  E  Insert the correct fuses in the module according to the following table    Mains Voltage 110 120 V Fuse 2 x 2AT  A
58. tivo  N   la LED S p A   Frosinone  Italia n   alcuna delle organizzazioni  sussidiarie di vendita pu   essere considerata responsabile per danni o perdite a persone o cose diretti o  consequenziali  che risultino da uso improprio dell apparecchiatura e degli accessori     2 1 GENERALE    Portatori di pace maker cardiaco non possono operare l apparecchiatura ne avvicinarsi alla  stessa quando    in funzione     Il paziente non deve essere in contatto con parti metalliche che sono connesse alla terra o che  hanno una grande capacit   di accoppiamento verso terra  per esempio  tavolo operatorio o  supporto metallico   Si consiglia l uso di teli antistatici     Evitare il contatto pelle pelle  per esempio tra braccia e corpo del paziente   Inserire un  materiale di separazione quale garza chirurgica asciutta     Quando si usano allo stesso tempo sullo stesso paziente unit   elettrochirurgiche ad alta  frequenza e dispositivi di monitoraggio fisiologico  tutti gli elettrodi di monitoraggio  che non  abbiano elementi resistivi o induttivi adatti a interferenze elettromagnetiche  debbono essere  posti quanto pi   lontano possibile dagli elettrodi della unit   elettrochirurgica    Evitare l uso di aghi di monitoraggio    La connessione agli elettrodi dovrebbe essere posizionata in modo tale da evitare il contatto sia  con il paziente che con altri cavi    Il livello di potenza dovrebbe essere il pi   basso utilizzabile per il lavoro da eseguire   Controllare sempre la placca pazient
59. tuir un peligro  El uso de cualesquiera elementos del sistema  electroquir  rgico  si no se presta la debida atenci  n  puede provocar quemaduras graves en el paciente   Lea atentamente todas las advertencias  precauciones e instrucciones y cerci  rese de que las ha  comprendido a la perfecci  n  antes de proceder a usar los electrodos activos  LED S p A  de Frosinone   Italia y las organizaciones de venta subsidiarias declinan toda responsabilidad  por los da  os  directos o  indirectos  contra las personas y las cosas que provocare el uso indebido del aparato y sus accesorios     2 1 CARACTER  STICAS GENERALES    E Los portadores de marcapasos cardiacos no pueden utilizar el aparato  ni acercarse al mismo  cuando est   en funcionamiento     E FI paciente nunca tiene que estar en contacto con las partes met  licas que est  n conectadas con  la puesta a tierra  o que tienen una gran capacidad de acoplamiento con la tierra  por ejemplo   mesa de operaciones o soporte met  lico   Es aconsejable emplear revestimientos contra la  electricidad est  tica  Hay que evitar que se produzca el contacto piel piel  por ejemplo  brazos y  cuerpo del paciente   poniendo en el medio material como gasa quir  rgica seca     E Cuando se usan  al mismo tiempo y con un mismo paciente  unidades electroquir  rgicas de alta  frecuencia y dispositivos de monitoreo fisiol  gico  todos los electrodos de monitoreo  que no  posean resistencias ni elementos inductivos id  neos para impedir las interferenc
60. uesto    il punto di connessione del manipolo  GIO    4 3 3 INDICATORI DI AVVERTIMENTO          Per protezione dell apparaecchiatura se la temperatura interna dell apparecchio supera i 75   C i display  lampeggiano  In questo caso    necessario interrompere l emissione ed attendere che la temperatura  interna ritorni a valori accettabili     Manuale d istruzioni   Instructions Manual   Manual de Instrucciones MA126IGBEa 13    GIMA SpA DIATERMO 106       5  CARATTERISTICHE TECNICHE       5 1 GENERALI    Descrizione dell apparecchiatura    Apparecchiatura elettrochirurgica ad alta frequenza per chirurgia minore monopolare  L apparecchiatura  permette la accurata predisposizione del livello di potenza di uscita e la scelta dell effetto coagulante  attraverso il fattore di cresta appropriato        Contenitore    Involucro metallico  per uso su consolle  con pannello frontale ricoperto da strato di policarbonato   Altezza  100 mm Lunghezza  180 mm  Profondita  180 mm Peso  2 8 Kg    Ingresso alimentazione  Selezionabile 115 o 230 V  50 60 Hz   Massima corrente  0 5 A  230 V o 1 A  115 V    Presa IEC con fusibili  selettore di tensione e interruttore incorporati        Indicatori    Indicatori digitali a led forniscono la indicazione del livello di uscita predisposto come segue   CUT  0 50 BLEND  0 45  COAG  0   40    Controlli potenza di uscita tramite due tasti   L uso dei tasti permette all utilizzatore di controllare con molta precisione la potenza di uscita in quanto     poss
61. ulsanti selettori di corrente    il seguente    9   CUT   TAGLIO  Premendo questo pulsante si predispone la corrente di taglio CUT  cio   corrente sinusoidale pura  ad    essere erogata quando il pedale    attivato  Il fattore di cresta della corrente di taglio monopolare      1 5   La condizione di predisposizione della corrente di taglio    indicata dal led verde che si illumina     9  BLEND  MIX  Premendo questo pulsante si predispone la corrente di miscelata BLEND  cio   corrente sinusoidale    modulata  ad essere erogata quando il pedale    attivato  Il fattore di cresta della corrente di taglio  monopolare      1 8  La condizione di predisposizione della corrente di taglio coagulato 1    indicata dal    led verde che si illumina   9    COAG    COAGULO  12 MA126IGBEa Manuale d   istruzioni   Instructions Manual   Manual de Instrucciones    DIATERMO 106 GIMA SpA  Premendo questo pulsante si predispone la corrente di Coagulazione COAG  cio   corrente sinusoidale  modulata  ad essere erogata quando il pedale    attivato  Il fattore di cresta della corrente di taglio  monopolare     2 5  La condizione di predisposizione della corrente di Coagualzione    indicata dal led  verde che si illumina     4 3 2 CONNETTORI    Connettore del pedale  Questo    il punto di connessione del pedale  Il pedale controlla l erogazione della corrente monopolare        Connettore placca paziente    D n  Questo    il punto di connessione della placca paziente  GIO    Connettore manipolo    O    Q
    