1. Pedestrian Start during the partial opening phase This menu allows fixing the control unit conduct in case it receives a Pedestrian Start command during the partial opening phase PAUS The gate stops and goes to pause ChiU the gate immediately starts closing no the gate goes on with the opening phase command is ignored A WARNING a Start command in any phase of partial opening will cause the total opening the Start Pedestrian command is always ignored during a total opening Automatic closing During the automatic operation the control unit will automatically close the gate when a set up time expires The Start command if enabled by St PA menu allows closing the gate before the set up time expires In semi automatic operation that is to say if the automatic closing function is disabled by setting the value to zero no will be displayed the gate can be closed through the start command only in this case St PA menu setup will be ignored If the control unit receives a Stop command when the gate is in pause it will automatically pass to the semi automatic operation Closing after transit During the automatic operation the pause count down starts from the set up value each time a photocell operates during the pause If the photocell operates during the opening time this time will be immediately stored as pause time This function allows having a fast closing as soon as transit through the gate
2. Entrada foto 2 Este men permite habilitare la entrada para las fotoc lulas de tipo 2 activas en apertura ver el p rrafo instalaci n no Entrada deshabilitada el cuadro la ignora No es necesario puentear con el com n Entrada habilitada incluso a puerta parada la maniobra de apertura no empieza si la fotoc lula est interrumpida Entrada habilitada solo en cierre Atenci n si se elige esta opci n es necesario deshabilitar el test de las fotoc lulas Test de los dispositivos de seguridad Para garantizar una mayor seguridad al usuario el cuadro realiza antes de que inicie cada ciclo de operaci n normal un test des dispositifs de s curit Si no hay anomal as funcionales la puerta entra en movimiento En caso contrario permanece parada y la l mpara de se alizaci n se enciende para 5 seg Todo el ciclo de test dura menos de un segundo no funci n no activa Foto test habilitado s lo por las fotoc lulas CoSt test habilitado s lo por las bandas de seguridad Ft Co test habilitado por fotoc lulas y bandas de seguridad A ATTENZIONE Si se utilizan protectores de goma conductiva NO active la prueba de funcionamiento para el protector La prueba de los protectores con contacto normalmente cerrado es posible s lo si se instala una centralita predispuesta para esta funci n V2 aconseja de mantener activo el TEST de las fotoc lulas para garantizar una major seguridad de todo el sistema
3. Pre blinking time Before any gate movement blinker will be activated for t PrE time to warn about the incoming motion Start command during the opening phase This menu allows fixing the control unit conduct in case it receives a Start command during the opening phase PAUS The gate stops and goes to pause ChiU The gate immediately starts closing no The gate go on with the opening phase command is ignored Select option PAUS to set up the step by step operation logic Select option no to set up the always open operation logic Start command during the closing phase This menu allows fixing the control unit conduct in case it receives a Start command during the closing phase StoP The gate stops and its cycle is considered as finished APEr The gate opens again Select option StoP to set up the step by step operation logic Select option APEr to set up the always open operation logic Start command during the pause This menu allows fixing the control unit conduct in case it receives a Start command when the gate is open during its pause phase ChiU the gate starts closing no command is ignored Select option ChiU to set up the step by step operation logic Select option no to set up the always open operation logic Apart from selected option the start command lets the gate close if it has been stopped by a stop command or if the automatic closing was not enabled SEPE ENGLISH
4. Tiempo de predestello Antes de cada movimiento de la puerta la l mpara de se alizaci n se activa por el tiempo t PrE para indicar una maniobra inminente Start en apertura Este men permite establecer el comportamiento del cuadro si se recibe un comando de Start durante la fase de apertura PAUS La puerta se para y entra en pausa ChiU La puerta se vuelve a cerrar inmediatamente no La puerta continua a abrirse el comando no viene sentido Para programar la l gica de funcionamiento paso paso elegir la opci n PAUS Para programar la l gica de funcionamiento abre siempre elegir la opci n no Start en cierre Este men permite establecer el comportamiento del cuadro si se recibe un comando de Start durante la fase de cierre StoP La puerta se para y el ciclo se considera terminado APEr La puerta se vuelve a abrir Para programar la l gica de funcionamiento paso paso elegir la opci n StoP Para programar la l gica de funcionamiento abre siempre elegir la opci n APEr Start en pausa Este men permite establecer el comportamiento del cuadro si se recibe un comando de Start mientras que la puerta est abierta y en pausa ChiU La puerta empieza a cerrarse no El comando no viene sentido Para programar la l gica de funcionamiento paso paso elegir la opci n ChiU Para programar la l gica de funcionamiento abre siempre elegir la opci n no Independientemente de la opci n elegi
5. Max motors load 4A Max accessories load 24V 10W Working temperature 20 C 60 C F1 F400mA F2 FIA Protection fuse F3 T2A 500V F4 T250mA Dimensions 295 x 230 x 100 mm Weight 1900g Protection IP55 DESCRIPTION OF THE CONTROL UNIT The control unit City6 is an innovative V2 product that guarantees a safe and reliable automation of industrial sliding gates and multi section doors City6 is provided with a display that not only makes programming simple but also allows a continuous monitoring of the input statuses in addition thanks to a menu structure the working schedule and the operation logic can be set easily In compliance with the European standards concerning electrical safety and electromagnetic compatibility EN 60335 1 EN 50081 1 and EN 50082 1 it has been equipped with the low voltage circuit total electric insulation motors included from the network voltage Other characteristics e Detecting obstacles by monitoring the power absorbed by the motors e Automatic learning of the operation time Tests for safety devices photocells ribbons and triacs before each opening Deactivation of safety inputs through the configuration menu no jumper is required for terminals concerning safety devices that have not been installed yet You will only need to disable this function from its relevant menu Control unit programming can be locked through the optional CL1 k
6. Antes de que la cuenta atr s termine pulsar la tecla MENU todos los par metros son rescritos con su valor de default y el menu de configuraci n es lanzado para poder efectuar todas las modificaciones necesarias Si el procedimiento de configuraci n de los par metros de default a sido lanzado por error es suficiente dejar que la cuenta atr s se termine El cuadro vuelve a funcionar normalmente sin modificar los par metros arreglados Tiempo de apertura En apertura el motor se acciona por el tiempo programado el cuadro puede interrumpir la apertura antes de agotar el tiempo si se detecta un obst culo o si interviene el final de carrera Tiempo de apertura parcial entrada peatonal Si se recibe un comando de Start Peatonal el cuadro abre la puerta por un tiempo reducido El tiempo m ximo programable es t AP Tiempo de cierre En cierre el motor se acciona por el tiempo programado el cuadro puede interrumpir la apertura antes de agotar el tiempo si se detecta un obst culo o si interviene el final de carrera Para evitar que la puerta no se cierre completamente se aconseja programar un tiempo superior al de apertura t AP Tiempo de cierre parcial entrada peatonal En caso de apertura parcial el cuadro utiliza este tiempo para el cierre El tiempo m ximo programable es t Ch Para evitar que la puerta no se cierre completamente se aconseja programar un tiempo superior al de apertura t APP
7. 0 5 t AP Antipatinamiento no Funci n deshabilitada no 4 0A Habilitaci n del sensor de obst culos no Si Regulaci n din mica del umbral del sensor de obst culos 0 0 2 0 Margen sobre el final del recorrido Tiempo de inversi n Standard 250 ms R pido 140 ms Visualizaci n de los contadores N mero total de ciclos completados visualiza los millares o las unidades N mero de ciclos antes del pr ximo mantenimiento n mero redondeado a los centenares y es programable a pasos de 1000 si se programa 0 la petici n est deshabilitada y se visualiza no Aprendizaje autom tico de los tiempos de trabajo Funci n deshabilitada Arranque del procedimiento de auto aprendizaje Fin programaci n No sale del men de programaci n Sale del men de programaci n memorizando los par metros programados TONVWdS4 ESPANOL ANOMALIAS DE FUNCIONAMIENTO En este parrafo se detallan algunas anomalias de funcionamiento que se pueden presentar se indica la causa y el procedimiento para solucionarla El led MAINS no se enciende Significa que falta tensi n a la placa del cuadro City6 1 Aseg rese que no exista una interrupci n de tensi n hacia el cuadro y que el seccionador est en ON 2 Antes de operar la central suprima la corriente mediante el seccionador montado sobre el cuadro o bien mediant
8. Before the end of the countdown press the key MENU all the parameters are rescribed with their default value and the configuration menu is started in order to make the necessary modifications If the procedure of loading of the default parameters has been started by mistake it is enough to wait for the countdown is up The control unit will start work normally without changing the parameters set Opening time The motor will be operated for the setup time in the opening phase in case there is an obstacle or the end of stroke operates the control unit can stop the opening phase before the relevant time expires Partial opening time pedestrian access When the control unit receives a Start Pedestrian command it will open the gate only for a shorter time Max allowed time to be setup is t AP Closing time The motor will be operated for the setup time in the closing phase In case there is an obstacle or the end of stroke operates the control unit can stop the opening phase before the relevant time expires To avoid that the gate does not close completely we recommend to setup a longer time than t AP opening time Partial closing time pedestrian access When the control unit receives a Start Pedestrian command it will use this time to close the gate Max allowed time to be setup is t CH1 To avoid that the gate does not close completely we recommend to setup a longer time than t APP opening time
9. Common Photocells type 1 N C contact Photocells type 2 N C contact Safety ribbons type 1 fixed N C contact Safety ribbons type 2 mobile N C contact Common Opening end of stroke N C contact Closing end of stroke N C contact Power output 24 VAC for photocells and other accessories Photocell TX power supply for functional test Motor see paragraph POWER SUPPLY AND MOTORS Clamps to connect the motor s earth system to the plant s earth system Flashing light 230VAC 40W Power supply see paragraph POWER SUPPLY AND MOTORS 400mA 2A 2A 500V Optional modules connector MAINS It shows that the control unit is power supplied It shows that there is an overload on accessories OVERLOAD power supply FCC It shows the opening end of stroke activation It shows the closing end of stroke activation Opening in progress Pause gate opened Closing in progress IP55 i DACE MAINS ren 1L1 3L2 5L3 Oo AF a LIMIT SWITCHES BE 24 J RECEIVER B OVERLOAD B B BH BB 85 86 P7 88 P9 P10 P11 P12 P13 P14 230Voc 40W A ATTENTION If the STOP input is not used must be jumpered with the commands common line COM EP ENGLISH CLOSING END OF STROKE OPENI
10. Le portail referme apr s le temps de pr s lection Fermeture apr s le passage no Fermeture apr s le passage d sactiv 0 5 20 0 Le portail se referme apr s la dur e pr r gl no Si Pause apr s le passage no Si Clignotant en pause Fonction des entr es de Start Mode Ouvre Ferme Mode Homme mort Mode Horloge Mode standard Les entr es Start sur bornes sont des habilit es Fonction du frein Entr e de STOP La commande d arr t arr t le portail le START suivant n inverse pas le mouvement La commande d arr t arr t le portail le START suivant inverse le mouvement DISPLAY DONNES TABLEAU FONCTIONS City6 DESCRIPTION DEFAULT MEMO DONNES Fot 1 Entr e photocellule 1 Fonctionne comme photocellule active en ouverture ou fermeture D sactiv Entr e photocellule 2 Fonctionne photocellule active en fermeture et avec portail arr t D sactiv Fonctionne photocellule active uniquement en fermeture Test des dispositifs de s curit Fonction non active Test habilit que pour les photocellules Test habilit que pour les barres palpeuses Test habilit soit pour les photocellules soit pour les barres palpeuses Entr e barre palpeuse 1 barre palpeuse fixe Entr e d saffect e la centrale l igno
11. Modalidad est ndar Las entradas de Start en los bornes est n deshabilitados Funci n de freno Entrada de STOP El comando de STOP para la puerta el siguiente impulso de START no invierte el movimiento El comando de STOP para la puerta el siguiente impulso de START invierte el movimiento DISPLAY TABLA DE FUNCION City6 DESCRIPCION DEFAULT Fot 1 Entrada FOTO 1 Funciona como fotoc lula activa en apertura y en cierre Deshabilitada Entrada FOTO 2 Funciona como fotoc lula activa en cierre y con la puerta parada Deshabilitada Funciona como fotoc lula activa s lo en cierre Test de los dispositivos de seguridad Funci n no activa Test habilitado s lo por las fotoc lulas Test habilitado s lo por las bandas de seguridad Test habilitado por fotoc lulas y bandas de seguridad Entrada banda 1 banda fija Entrada deshabilitada el cuadro la ignora Entrada habilitada para las bandas de goma conductiva Entrada habilitada para las bandas de seguridad est ndar con contacto n c Entrada banda 2 banda en movimiento no Entrada deshabilitada el cuadro la ignora rESi Entrada habilitada para las bandas de goma conductiva StAn Entrada habilitada para las bandas de seguridad est ndar con contacto n c no Si Entrada finales de carrera
12. The led displays above the P7 and P8 contacts respectively indicate the entry status for type 1 and 2 sensitive edge See the following table to establish the status according to the kind of edge installed Traditional edge Conductive rubber edge Red and green led Contact open Contact open displays off alarm alarm Red led display on Compressed edge Green led display off closed OI Red and green led Nominal resistance displays on ok END OF STROKE City6 control unit supports the end of stroke equipped with a normally close switch that will be opened as soon as the gate reaches its position desired Ends of strokes must be connected to the control unit terminal board as follows e end of stroke in opening phase between terminal P10 and 89 e end of stroke in closing phase between terminal P11 and P9 The led displays above the P10 and P11 contacts respectively show the end of strokes status If the led display is on the contact is shut if it is off the contact is open l 00 For a better safety you can fit a stop switch that will cause the immediate gate stop when activated This switch must have a normally close contact that will get open in case of operation In case the stop switch is operated while the gate is open the automatic closing function will always be disabled To close the gate again you will need a start command if the start function in pause is disabled it will be temporarily en
13. FRANCAIS ANOMALIE DE FONCTIONNEMENT En ce paragraphe sont num r es aucunes anomalies de fonctionnement qu on se puissent pr senter on indique la cause et la proc dure pour les r soudre Le led MAINS ne s allume pas Ga signifie que manque tension sur la platine de l armoire City6 1 Assurez vous qu il n y ait pas d interruption de tension en amont de l armoire de commande et que le sectionneur soit sur ON Avant d agir sur l armoire de commande couper le courant au moyen du sectionneur mont sur l armoire ou d autre dispositif en amont sur la ligne d alimentation Contr ler si le fusible F3 est br l En ce cas le remplacer avec un autre du m me valeur La DEL MAINS est allum e mais l afficheur ne s allume pas Cela veut dire qu il n y a pas de tension sur le secondaire du transformateur 1 Avant d agir sur l armoire couper le courant au moyen du sectionneur mont sur l armoire ou d autre dispositif en amont sur la ligne d alimentation Contr ler si le fusible F1 est br l En ce cas le remplacer avec un autre du m me valeur Si le remplacement du fusible n a pas pu r soudre le probl amp me envoyer l armoire la V2 pour la r paration Le led OVERLOAD est allum Signifie qu est pr sent un surcharge sur l alimentation des accessoires Enlever la partie extractible contenant les bornes d P1 P14 Le led OVERLOAD s eteigne Eliminer la cause du surcharge Remettre la partie extractible d
14. MENU Y UP PARA LA PROGRAMACION La programaci n de las funciones y de los tiempos del cuadro se efectua en un men de configuraci n expreso en el que se entra y nos movemos por medio de las teclas DOWN MENU y UP situadas debajo del display Para entrar en la modalidad de programaci n mientras el display visualiza el panel de control mantener pulsada la tecla MENU hasta que en el display no aparece t AP El men de configuraci n consiste en un listado de voces configurables la sigla que aparece en el display indica la voz seleccionada en ese momento Pulsando la tecla DOWN se pasa a la siguiente voz pulsando la tecla UP se vuelve a la voz anterior Pulsando la tecla MENU se visualiza el valor actual de la voz seleccionada y eventualmente se puede modificar La ultima voz de men FinE permite memorizar las modificaciones efectuadas y volver al funcionamiento normal del cuadro Para no perder la propia configuraci n es obligatorio salir de la modalidad de programaci n mediante esta voz del menu A ATENCION si no se efect a ninguna operaci n durante m s de un minuto el cuadro sale de la modalidad de programaci n sin guardar las programaciones y las modificaciones efectuadas que ser n perdidas Manteniendo pulsada la tecla DOWN las voces del men de configuraci n se desplazan r pidamente hasta aparecer la voz FinE De la misma forma manteniendo pulsada la tecla UP las voces se desplazan r pidamente hacia atr s hast
15. cnico ponerse en contacto con el servicio asistencia V2 TEL 39 01 72 81 24 11 La V2 se reserva el derecho de aportar eventuales modificaciones al producto sin previo aviso ademmas no se hace responsable de danos a personas 0 cosas debidos a un uso improprio o a una instalaci n err nea A Antes de proceder en las installacion y la programmacion es aconsejable leer bien las instrucciones Dicho manual es destinado exclusivamente a t cnicos calificados en las installacione de automatismos Ninguna de las informacciones contenidas en dicho manual puede ser de utilidad para el usuario final Cualquiera operacion de manutencion y programacion tendr que ser hecha para t cnicos calificados en las installacione de automatismos LA AUTOMATIZACION DEBE SER REALIZADA EN CONFORMIDAD A LAS VIGENTES NORMATIVAS EUROPEAS EN 60204 1 Seguridad de la maquinaria Equipamiento electrico de las maquinas partes 1 reglas generales Seguridad en el uso de cierres automatizados metodos de prueba Seguridad en el uso de cierres automatizados requisitos EN 12445 EN 12453 El instalador debe proveer la instalaci n de un dispositivo ej interruptor magnetot rmico que asegure el seccionamiento omnipolar del aparato de la red de alimentaci n La normativa requiere una separaci n de los contactos de almenos 3 mm en cada polo EN 60335 1 Una vez efectuada la conexi n a los bornes es necesario colocar unas bridas a los cab
16. il ponticello di selezione della tensione sia impostato correttamente Un impostazione non corretta pud danneggiare seriamente la centrale Trifase 400V VOLTAGE I y oT SELECTOR Per il collegamento di terra dei motori con la terra dell impianto utilizzare i morsetti W4 e W5 Se la direzione di movimento del cancello contraria a quella desiderata invertire i collegamenti su W2 e W3 A ATTENZIONE la centrale non fornisce nessuna protezione sui motori Si consiglia di installare un dispositivo salvamotore prima del motore 82 LRH 230Voc 40W Trifase 230V rispetto allo schema precedente cambia solo il ponticello di selezione della tensione ONVITVLI ITALIANO LAMPEGGIATORE La centrale City6 prevede l utilizzo di un lampeggiatore a 230V 40W con intermittenza interna Collegare i cavi del lampeggiante ai morsetti B1 e B2 della centrale II W4 W5 TE Pr UN FOTOCELLULE A seconda del morsetto a cui vengono collegate la centrale suddivide le fotocellule in due categorie Fotocellule di tipo 1 sono installate sul lato interno del cancello e sono attive sia durante l apertura sia durante la chiusura In caso di intervento delle fotocellule di tipo 1 la centrale ferma il cancello quando il fascio viene liberato la centrale apre completamente il cancello Fotocellule di tipo 2 sono installate sul lato esterno del cancello e sono attive solo durante la chiusura In caso di inte
17. n El rea 1 representa la lectura total de los ciclos completados con las teclas Up y Down es posible alternar la visualizaci n entre millares o unidades El rea 2 representa la lectura del n mero de ciclos que faltan para la pr xima intervenci n de mantenimiento el valor est redondeado a los centenares El rea 3 representa la programaci n de este ltimo contador a la primera pulsaci n de la tecla Up o Down el valor actual del contador se redondea a los millares cada pulsaci n siguiente aumenta o disminuye la programaci n de 1000 unidades El contador anterior visualizado viene as perdido programando el nuevo n mero Se alaci n de la necesidad de mantenimiento Cuando el contador de ciclos que faltan para la pr xima intervenci n de mantenimiento llega a cero el cuadro sefala la petici n de mantenimiento mediante un predestello adicionales de 5 segundos de la l mpara de senalizaci n La se alaci n se repite al comienzo de cada ciclo de apertura hasta que el instalador no acceda al menu de lectura y programaci n del contador programando eventualmente un nuevo n mero de ciclos despu s de los cuales ser pedido nuevamente el mantenimiento Si no se programa un nuevo valor dejando el contador a cero la funci n de se alaci n de la petici n de mantenimiento queda deshabilitada y la se alaci n no ser repetida A ATENCION las operaciones de mantenimiento tienen que ser efectuadas exclusi
18. programmazione senza salvare le impostazioni e le modifiche effettuate vengono perse Tenendo premuto il tasto DOWN le voci del menu di configurazione scorrono velocemente finch non viene visualizzata la voce FinE Analogamente tenendo premuto il tasto UP le voci scorrono velocemente all indietro finch non viene visualizzata la voce t AP In questo modo pu essere aggiunta velocemente la fine o l inizio della lista Esistono tre tipologie di voci di menu Menu di funzione Menu di tempo Menu di valore Impostazione dei menu di funzione menu di funzione permettono di scegliere una funzione tra un gruppo di possibili opzioni Quando si entra in un menu di funzione viene visualizzata l opzione attualmente attiva mediante i tasti DOWN e UP possibile scorrere le opzioni disponibili Premendo il tasto MENU si attiva l opzione visualizzata e si ritorna al menu di configurazione Impostazione dei menu di tempo menu di tempo permettono di impostare la durata di una funzione Quando si entra in un menu di tempo viene visualizzato il valore attualmente impostato la modalit di visualizzazione dipende dal valore impostato e tempi inferiori al minuto vengono visualizzati in questo 4 8 8 8 Ogni pressione del tasto UP fa aumentare il tempo impostato di mezzo secondo ogni pressione del tasto down lo fa diminuire di mezzo secondo e tempi compresi tra 1 e 10 minuti vengono visualizzati in questo formato Ogn
19. Predestello prolongado Cuando se da un comando de start la l mpara de se alizaci n se enciende inmediatamente pero la puerta tarda en abrirse Significa que se ha acabado la cuenta de ciclos programado en el cuadro y la puerta requiere una intervenci n de mantenimiento
20. START command gate continues the motion STOP command stops the gate START command starts moving in the opposite direction DISPLAY City6 FUNCTION TABLE DESCRIPTION DEFAULT Fot 1 PHOTO 1 input Input is available for the connection of the photocell Not available PHOTO 2 input Photocell is active in closing and also when the gate is still Not available Photocell is active during the closing Test of safety devices Function not active Test enabled only for photocells Test enabled only for safety edges Test enabled either for photocells or for safety edges Border 1 input fixed border Input disabled the control unit ignores it Input enabled for conductive rubber ribbons Input enabled for standard safety ribbons with normally closed contact Border 2 input mobile border no Input disabled the control unit ignores it rESi Input enabled for conductive rubber ribbons StAn Input enabled for standard safety ribbons with normally closed contact no Si End of stroke inputs 0 5 t AP Anti skid no Function disabled no 4 0A Obstacle sensor level no Si Dynamic regulation of the obstacle sensor threshold 0 0 2 0 Allowance on the end stroke Inversion time of the movement Standard 250 ms Fa
21. START e START P La centrale City6 dispone di due ingressi di attivazione START e START P la cui funzione dipende dalla modalit di funzionamento programmata e Modalit standard START START un comando provoca l apertura totale del cancello START P START PEDONALE un comando provoca l apertura parziale del cancello Modalit Apri Chiudi START APERTURA comanda sempre l apertura START P CHIUSURA comanda sempre la chiusura Il comando di tipo impulsivo cio un impulso provoca la totale apertura o chiusura del cancello Modalit Uomo Presente START APERTURA comanda sempre l apertura START P CHIUSURA comanda sempre la chiusura Il comando di tipo monostabile cio il cancello viene aperto o chiuso fintanto che il contatto chiuso e si arresta immediatamente se il contatto viene aperto Modalit Orologio Questa funzione permette di programmare nell arco della giornata le fasce orarie di apertura del cancello utilizzando un timer esterno START START un comando provoca l apertura totale del cancello START P 2 START PEDONALE un comando provoca l apertura parziale del cancello Il cancello rimane aperto fintanto che il contatto rimane chiuso sull ingresso quando il contatto viene aperto inizia il conteggio del tempo di pausa scaduto il quale il cancello viene richiuso ATTENZIONE indispensabile abilitare la richiusura automatica In tutte le modalit gli ingres
22. allows programming the gate opening time during the day by making use of an external timer START START a command will cause the complete opening of the gate START P PEDESTRIAN START a command will cause the partial opening of the gate The gate stays open completely or partially while the contact is closed on input as soon as the contact is open the pause time count down will start after which the gate will be closed again ATTENTION Automatic closing must be enabled In all modes inputs must be connected to devices having normally open contacts Connect cables of device controlling the START input between terminals P1 and P4 of the control unit Connect cables of device controlling the START P input between terminals P2 and P4 of the control unit The START input function can also be activated by pressing UP key outside the programming menu or by means of a remote control stored on channel 1 see relevant instructions of MR2 receiver The START P input function can also be activated by pressing DOWN key outside the programming menu or by means of a remote control stored on channel 2 The led displays above the P1 and P2 contacts respectively indicate the START and PEDESTRIAN START entry status If the led display is on the contact is shut if it is off the contact is open BBO 000000 00 P12 PM P1 1 P3 P4 P5 P6 P7 P8 P9 PIO Pi PI M Sheehy m a gt x Bike a EE RO Hs amp 3 3 IND
23. as follows 9 8 8 5 each time you press UP key current time value increases of half a minute vice versa each time you press the DOWN key current time value decreases of half a minute By holding down the UP key you can quickly increase the time value up to reach the max value allowed for this item Vice versa by holding down the DOWN key you can quickly decrease the time value down to reach 0 0 In some circumstances setting the value to 0 means that the relevant function is disabled in this case no will appear instead of 0 0 By pressing on MENU you will confirm the displayed value and you will return to the configuration menu Value menu setup Value menus are similar to time menus however the setup value can be any number By holding down UP or DOWN keys the value will increase or decrease slowly QUICK CONFIGURATION This paragraph concerns a quick procedure to set the control unit and set it at work immediately We recommend following these instructions in order to check quickly the correct operation of control unit motor and accessories and then changing the configuration in case of any non satisfactory parameter Please refer to the paragraph Control unit configuration for the item position inside the menu as well as for the available options for each item 1 Call up a default configuration see paragraph LOADING OF DEFAULT PARAMETERS 2 Set items StoP Foto CoSt and FC En ac
24. el tiempo de pausa vuelve a empezar por el valor programado en este menu De la misma forma si la fotoc lula interviene durante la apertura inmediatamente se carga este tiempo como tiempo de pausa Esta funci n permite un cierre r pido despu s del transito del veh culo consiguiendo utilizar un tiempo inferior a Ch AU Si se programa no se utiliza el tiempo Ch AU En el funcionamiento semiautom tico esta funci n no est activada Pausa despu s del tr nsito Para minimizar el tiempo en que la puerta est abierta es posible hacer cerrar la puerta cada vez que intervienen las fotoc lulas En caso de funcionamento autom tico el tiempo de pausa es Ch tr Si las fotoc lulas instaladas son de tipo 1 o 2 la puerta es en pausa solamente despu s de la intervenci n de ambas las fotoc lulas L mpara de sefializaci n en pausa Normalmente la l mpara de sefializaci n funciona solo durante el movimiento de la puerta Si esta funci n est habilitada la l mpara de se alizaci n funciona tambi n durante el tiempo de pausa Funcionamiento de las entradas de Start Este men permite elegir la modalidad de funcionamiento de las entradas ver p rrafo ENTRADAS DE ACTIVACI N AP CH Modalidad Abre Cierra PrES Modalidad Hombre Presente oroL Modalidad Reloj StAn Modalidad est ndar no Las entradas de Start en los bornes est n deshabilitados Las entradas radio funcionan seg n la modalidad 5 A n
25. is completed therefore a time shorter than CH AU is generally used Ch AU will be used when no is set up As for semi automatic operation this function is not active Pause after transit In order to let the gate open for the shortest possible time it is possible to stop the gate once the passage before the photocells is detected If the automatic working is enabled the time of the pause is Ch tr If the photocells are type 1 and type 2 the gate enters the phase of pause only after the detections before both the photocells Blinker during pause time Blinker usually operates during the gate motion only however if this function is enabled blinker will be on during the pause time too Activation input function This menu allows selecting input operation modes see paragraph ACTIVATION INPUTS AP CH Open Close command PrES Manned operation oroL Timer mode StAn Standard mode no Start inputs from terminal board are disabled Radio inputs operate in standard mode SEA n Brake function This menu allows you to active the braking function thanks to which you can prevent a heavy gate following a command or a safety intervention due to inertia continuing to move for a few seconds rather than blocking immediately A IMPORTANT if the motor has an automatic electromagnetic brake this function must be turned off Stop Input This menu permits to select the functions associated to the command of ST
26. lectrique prot g e avec un interrupteur magn tothermique diff rentiel conform ment aux r glementations de la loi L alimentation n cessaire d pend du type de moteur utilis et peut tre de trois types e triphas e 400V e triphas e 230V monophas e 230V Les sch mas suivants indiquent de quelle mani re l alimentation et les c bles du moteur doivent tre branch s et de quelle mani re doit tre r gl la liaison de s lection de la tension pour chaque cas A ATTENTION avant de mettre sous tension s assurer que la liaison de s lection de la tension soit r gl e correctement Une configuration non correcte peut s rieusement endommager l armoire de commande Triphas e 400V 82 LRH 230Voc 40W Triphas e 230V par rapport au sch ma pr c dent seulement la liaison de s lection de la tension change Monophas e 230V dans ce cas il est n cessaire de monter un condensateur de d marrage 82 LRH 230Voc 40W Pour la connexion de terre des moteurs avec la terre de l installation utiliser les bornes W4 et W5 Si la direction de mouvement du portail est contraire celle souhait e inverser les branchements sur W2 et W3 A ATTENTION l armoire de commande ne fournit aucune protection sur les moteurs Il est conseill d installer un discontacteur avant du moteur SIVDNVYS FRANCAIS CLIGNOTANT L armoire City6 pr voit l emploi d un clignotant 230V 40W ave
27. logique de fonctionnement pas pas choisir l option ChiU Pour tablir la logique de fonctionnement ouvre toujours choisir l option no ind pendamment de l option choisie le commande Start referme le portail si a t bloque avec un commande de Stop ou si n est pas habilit e la re fermeture automatique SIVDNVYS FRANCAIS Start pi tonne en ouverture partielle Ce menu permet d tablir le comportement de l armoire s il recoit un commande de Start Pi tonne pendant la phase d ouverture partielle PAUS Le portail s arrete et entre en pause ChiU Le portail commence se refermer no Le portail continue s ouvrir le commande est ignor A ATTENTION Un commande de Start recu en n importe quelle phase de l ouverture cause une ouverture totale le commande de Start Pi tonne est toujours ignor pendant une ouverture totale Fermeture automatique Dans le fonctionnement automatique l armoire referme automatiquement le portail l ch ance du temps tablit Si le commande de Start est habilit du menu St PA permet de fermer le portail m me en avance de l ch ance du temps tablit Dans le fonctionnement semi automatique c est dire si la fonction de fermeture automatique viens des habilit en mettant le valeur z ro le display visualise no le portail peut tre re ferm seulement avec le commande de Start en ce cas le postage du menu St PA viens ignor Si pendan
28. roulent tr s vite jusqu quand ne vient pas visualis la voix FinE De facon analogue en appuyant la touche UP les voix roulent vite en sens contraire jusqu quand vient visualis la voix t AP De cette facon on peut joindre rapidement le d but et la fin de la liste Il existent trois typologies de voix de menu Menu de fonction Menu de temps Menu de valeur Postage du menu de fonction Les menus de fonction permettent de choisir une fonction entre un group de possibles options Quand on entre dans un menu de fonction il est visualis e l option actuellement active travers des touches DOWN et UP il est possible couler les options disponibles Appuyant la touche MENU on active l option visualis et on retourne au menu de configuration Postage des menus de temps Les menus de temps permettent de poster la dur e d une fonction Quand on entre dans un menu de temps vient visualis le valeur actuellement tablit le mode de visualisation d pends du valeur tablit Les temps inf rieurs au minute sont visualis s en ce format H 8 8 H Chaque pression du touche UP augmente le temps tablit de demi second chaque pression du touche DOWN diminue de demi second es temps compris entre 1 et 10 minutes sont visualis s en ce format 8 8 8 8 Chaque pression du touche UP augmente le temps tablit de 5 seconds chaque pression du touche DOWN diminue de 5 seconds es temps sup rieurs aux 10 mi
29. superar un maximo de 0 5A del valor programado para el par metro SenS Margen sobre el final del recorrido Si la instalaci n prev que el cancel avance hasta golpear contra un tope mec nico al final del recorrido en apertura o en cierre es necesario programar un margen sobre el final del recorrido en el cual el sensor de obst culos no provoque el retiro de la seguridad a causa del golpe contra el tope sino que deje concluir el ciclo Si se programa un margen superior a los tiempos de trabajo cualquier intervenci n del sensor de obst culos provocar el final del ciclo Si se programa cero cualquier intervenci n del sensor de obst culos provocar el repliegue del cancel TONVdS3 ESPANOL Tiempo de inversion El tiempo de inversi n es el tiempo necesario para invertir el movimiento del motor cuando se activa un dispositivo de seguridad StAn inversi n standard 250ms FASt inversi n r pida 140ms Visualizaci n de los contadores Este men permite visualizar el contador de los ciclos de apertura completados y de programar el mantenimiento ver el p rrafo Lectura del contador de ciclos m s adelante Aprendizaje automatico de los tiempos de trabajo Este men activa un procedimiento que permite al cuadro de detectar aut nomamente la duraci n optima de los tiempos de trabajo ver el p rrafo Configuracion rapida Eligiendo la opci n Go el men de configuraci n se sierra y empi
30. 1 Quand on a effectu les branchements la borniere il faut mettre des bandes sur les conducteurs tension qui se trouvent en proximit de la borniere et sur les conducteurs pour le branchement des parties externes accessoires De cette maniere en cas de d tachement d un conducteur on vite que les partie en tension puissent aller en contact avec les parties faible tension de s curit Pour la connexion de tubes rigides ou flexibles utiliser des raccordements poss dant le IP55 niveau de protection L installation requiert des comp tences en mati re d lectricit et m caniques doit tre faite exclusivement par techniciens qualifi s en mesure de d livrer l attestation de conformit pour l installation Directive 89 392 CEE IIA Il est obligatoire se conformer aux normes suivantes pour fermetures v hiculaires automatis es EN 12453 EN 12445 EN 12978 et toutes ventuelles prescriptions nationales M me l installation lectrique ou on branche l automatisme doit r pondre aux normesen vigueur et tre fait r gles de l art La r gulation de la force de pouss e du portail doit tre mesur e avec outil sp cial et r gl e selon les valeurs maxi admis par la norme EN 12453 Nous conseillons d utiliser un poussoir d urgence installer pr s de l automatisme branch l entr e STOP de l armoire de commande de facon qui soit possible l arr t imm diat du portail en cas de danger Branche
31. A seconda del morsetto a cui vengono collegate la centrale suddivide le coste sensibili in due categorie Coste di tipo 1 fisse sono installate su muri o altri ostacoli fissi a cui il cancello si avvicina durante l apertura In caso di intervento delle coste di tipo 1 durante l apertura del cancello la centrale fa richiudere per 3 secondi quindi va in blocco in caso di intervento delle coste di tipo 1 durante la chiusura del cancello la centrale va immediatamente in blocco La direzione di azionamento del cancello al successivo comando di START o START PEDONALE dipende dal parametro STOP inverte o prosegue il moto Coste di tipo 2 mobili sono installate all estremit del cancello In caso di intervento delle coste di tipo 2 durante l apertura del cancello la centrale va immediatamente in blocco in caso di intervento delle coste di tipo 2 durante la chiusura del cancello la centrale fa riaprire per 3 secondi quindi va in blocco La direzione di azionamento del cancello al successivo comando di START o START PEDONALE dipende dal parametro STOP inverte o prosegue il moto Entrambi gli ingressi sono in grado di gestire sia la costa classica con contatto normalmente chiuso sia la costa a gomma conduttiva con resistenza nominale 8 2 kohm Collegare i cavi delle coste di tipo 1 tra i morsetti P7 e P9 Collegare i cavi delle coste di tipo 2 tra i morsetti P8 e P9 Per soddisfare i requisiti della normativa EN12978 necessario
32. ATA City6 FUNCTION TABLE DESCRIPTION DEFAULT 0 0 5 0 Gate opening time 15 0 0 0 t AP1 Opening time of pedestrian gate 6 0 0 0 5 0 Gate closing time 16 0 0 0 t Ch Closing time of pedestrian gate 7 0 0 5 1 0 Pre flashing time 1 0 no Pre flashing disabled it corresponds to 0 Start in opening Start command is not available Command close gate Stop the gate and goes in pause Start in closing Start command stop the gate Start command open the gate Start in pause Start command is not available Start command closes the gate Pedestrian in opening Pedestrian start command is not available Pedestrian start command closes the gate Gate goes in pause Automatic closing no The gate closes after the setup time 0 5 20 0 The automatic closing is not active it corresponds to 0 Closing after passage no Closing after passage disabled 0 5 20 0 Gate stop for a time to be set between 0 5 to 20 no Si Pause after transit no Si Flashlight in pause Activation input function Open Close command Manned operation Timer mode Standard mode Start inputs from terminal board are disabled Brake function STOP input STOP command stops the gate pressing the
33. Direttiva Bassa Tensione secondo le norme EN 60335 1 EN 60335 2 103 99 05 CEE Direttiva Radio secondo le norme EN 301 489 3 Racconigi li 12 11 200 Il rappregentante legal della V2 SPA 0 0 ost Fal CARATTERISTICHE TECNICHE AOOV trifase 230V trifase Alimentazione 230V monofase Carico max motore 4A Carico max accessori 24V 10W Temperatura di lavoro 20 C 60 C F1 F400mA F2 F1A Fusibili di protezione F3 T2A 500V F4 T250mA Dimensioni 295 x 230 x 100 mm Peso 1900g Protezione IP55 DESCRIZIONE DELLA CENTRALE La centrale digitale City6 6 un innovativo prodotto V2 SPA che garantisce sicurezza ed affidabilit per l automazione di cancelli scorrevoli e portoni sezionali industriali La City6 dotata di un display il quale permette oltre che una facile programmazione il costante monitoraggio dello stato degli ingressi inoltre la struttura a men permette una semplice impostazione dei tempi di lavoro e delle logiche di funzionamento Nel rispetto delle normative europee in materia di sicurezza elettrica e compatibilit elettromagnetica EN 60335 1 EN 50081 1 e EN 50082 1 caratterizzata dal completo isolamento elettrico tra la parte di circuito digitale e quella di potenza Altre caratteristiche Rilevamento degli ostacoli mediante monitoraggio della corrente assorbita dai motori Apprendimento automatico dei tempi di lavoro Test dei dispositivi di
34. E ENGLISH PLUG IN RECEIVER City6 control unit is suitable for plugging in a Personal Pass MR2 receiver having a high sensitivity super heterodyne architecture A WARNING it is necessary to turn off the control unit power before doing the operations mentioned here below Pay attention to the way you connect the removable modules MR2 module receiver is provided with 4 channels and each of them is suitable for a command of City6 control unit CHANNEL 1 START CHANNEL 2 PEDESTRIAN START CHANNEL 3 STOP CHANNEL 4 KEPT FOR FUTURE USE A WARNING Before programming 4 channels and function logics read carefully the instructions of MR2 EXTERNAL AERIAL We suggest to use the external aerial model ANS433 in order to guarantee the maximal range Connect the antenna hot pole to terminal A2 of the control unit and the braiding to terminal A1 AN INTERFACE The ADI Additional Devices Interface interface of the control unit City6 allows the connection to V2 optional modules See V2 catalogue to check the ones fitting this control unit A WARNING Please read the instructions of each single module to install the optional modules ELECTRIC CONNECTIONS TABLE Antenna shield Antenna START opening control for the connection of control devices with N O contact START P opening controls for pedestrian access for the connection of control devices with N O contact Stop command N C contact
35. ENTION e Si l on utilise des barres palpeuses en caoutchouc conducteur NE PAS activer le test de fonctionnement pour la barre palpeuse Le test des barres palpeuses avec contact normalement ferm est possible seulement si une centrale de commande pr dispos e pour cette fonction est install e V2 conseille de maintenir active le Test des dispositifs de s curit avec le but de garantir une s curite plus haute du syst me Entr e barre palpeuse 1 Ce menu permet d habiliter l entr e pour les barres palpeuses de type 1 fixe voir paragraphe installation no Entr e des habilit e l armoire l ignore Il n est pas n cessaire pointer avec le commun entr e habilit e pour les barres palpeuses standard avec contact normalement ferm entr e habilit e pour les barres palpeuses caoutchouc conducteur avec r sistance nominale 8 2 kohm Entr e Barre palpeuse 2 Ce menu permet d habiliter l entr e pour les barres palpeuses de type 2 mobiles voir paragraphe installation no Entr e des habilit e l armoire l ignore Il n est pas n cessaire pointer avec le commun entr e habilit e pour les barres palpeuses standard avec contact normalement ferm entr e habilit e pour les barres palpeuses caoutchouc conducteur avec r sistance nominale 8 2 kohm Entr es but es de fin de course La centrale City6 permet le branchement de but es de fin de courses m caniques contact normalement ferm qui sont
36. Entrada Banda de Seguridad 1 Este men permite habilitare la entrada para las banda de seguridad de tipo 1 las fijas ver el p rrafo instalaci n no Entrada deshabilitada el cuadro la ignora No es necesario puentear con el com n Entrada habilitada para las bandas est ndar con contacto normalmente cerrado Entrada habilitada para las bandas de goma conductiva con resistencia nominal 8 2 kohm Entrada Banda de Seguridad 2 Este men permite habilitare la entrada para las banda de seguridad de tipo 2 las que est n en movimiento ver el p rrafo instalaci n no Entrada deshabilitada el cuadro la ignora No es necesario puentear con el com n Entrada habilitada para las bandas est ndar con contacto normalmente cerrado Entrada habilitada para las bandas de goma conductiva con resistencia nominal 8 2 kohm Entrada finales de carrera El cuadro de maniobras City6 permite la conexi n de finales de carrera mec nicos contacto normalmente cerrado que se activan con el movimiento de las puerta e indican al cuadro la posici n de completa apertura o cierre no Las entradas finales de carrera est n deshabilitadas Si Las entradas finales de carrera est n habilitadas Antipatinamiento Cuando una maniobra de apertura o cierre queda interrumpida con un comando o por la intervenci n de la fotoc lula el tiempo programado para la siguiente maniobra en sentido contrario ser a excesivo y por eso el cuadro acc
37. Funci n de freno Este men permite activar la funci n de freno gracias a la cual es posible impedir que un cancel pesado como resultado de un comando o por la intervenci n de un elemento de seguridad a causa de la inercia continue el movimiento por algunos segundos en vez de bloquearse inmediatamente AN ATENCI N Si el motor est dotado de freno electromec nico autom tico esta funci n debe ser obligatoriamente inhabilitada Entrada Stop Este men permite seleccionar las funciones asociadas al comando de STOP ProS El comando de STOP para la cancela al siguiente comando de START la cancela reemprende el movimiento en la direcci n precedente invE El comando de STOP para la cancela al siguiente comando de START la cancela reemprende el movimiento en la direcci n opuesta a la precedente La programaci n del par metro STOP determina tambi n la direcci n del movimiento de la puerta parada despu s de la intervenci n de las bandas sensibles o del sensor de obst culos despu s de un comando de START A ATENCION durante la pausa el comando de STOP para el tiempo de pausa el siguiente comando de START vuelve a cerrar la puerta Entrada foto 1 Este men permite habilitare la entrada para las fotoc lulas de tipo 1 activas en apertura y en cierre ver el p rrafo instalaci n no Entrada deshabilitada el cuadro la ignora No es necesario puentear con el com n Entrada habilitada TONVdS3 ESPANOL
38. NE al termine del ciclo di apprendimento sul display viene visualizzato per alcuni istanti il massimo valore di assorbimento di corrente rilevato durante il ciclo ad eccezione delle fasi di spunto L installatore pu basarsi su questo dato per stabilire la soglia del sensore di ostacoli tenendo conto che necessario lasciare un po di margine per evitare che il minimo attrito o impuntamento blocchi il cancello CONFIGURAZIONE DELLA CENTRALE In questo paragrafo viene illustrata passo passo la procedura per la configurazione di tutti i parametri di funzionamento della centrale City6 E possibile fare una configurazione completa della centrale seguendo tutti i passi della procedura o selezionare solo le voci che interessano In entrambi i casi per rendere attiva la nuova configurazione indispensabile eseguire la corretta procedura di uscita tramite la voce FinE La centrale City6 dispone di una procedura di autoapprendimento dei tempi di lavoro consigliabile perci impostare inizialmente una configurazione standard paragrafo precedente eseguire l autoapprendimento e in seguito cambiare le voci che non soddisfano ONVITVLI ITALIANO CARICAMENTO DEI PARAMETRI DI DEFAULT In caso di necessit possibile riportare tutti i parametri al loro valore standard o di default vedere la tabella riassuntiva finale A ATTENZIONE Questa procedura comporta la perdita di tutti i parametri personalizzati e perci stata ins
39. NG END OF STROKE CONTROL PANEL When power is on the control unit checks that display correctly operates by switching on all segments for 1 5 sec 8 8 8 8 Firmware version e g Pr 1 2 will be viewed in the following 1 5 sec Panel will be viewed upon completion of this test OPEN CONTACT CLOSED CONTACT OPENING IN PROGRESS I PAUSE GATE OPENED CLOSING IN PROGRESS START SAFETY RIBBON 2 DOWN SAFETY RIBBON 1 PEDESTRIAN START UP STOP PHOTOCELL 2 MENU PHOTOCELL 1 The control panel represents the physical status of the terminal board contacts and of the program mode keys if the upper vertical segment is on the contact is closed if the lower vertical segment is on the contact is open the above picture shows an instance where the inputs START START P FOTO 1 FOTO 2 COSTA 1 COSTA 2 and STOP have all been correctly connected If conductive rubber type sensitive edges are installed and both segments come on simultaneously this indicates that the entry is closed on nominal resistance programming push buttons as soon as a push button is pressed its relevant point turns on The arrows on the display left side show the status of the ends of stroke The arrows turn on when its end of stroke shows that the gate is completely closed or completely open The arrows on the display right side show the gate status The highest arrow turns on when the gate is into its opening phase If it blinks it means that the op
40. NTATTO CHIUSO APERTURA IN CORSO PAUSA CANCELLO APERTO CHIUSURA IN CORSO FINECORSA DI CHIUSURA FINECORSA DI APERTURA COSTA 2 COSTA 1 UP FOTOCELLULA 2 FOTOCELLULA 1 Il pannello di controllo in stand by indica lo stato fisico dei contatti alla morsettiera e dei tasti di programmazione se acceso il segmento verticale in alto il contatto chiuso se acceso il segmento verticale in basso il contatto aperto il disegno sopra illustra il caso in cui gli ingressi START START P FOTO 1 FOTO 2 COSTA 1 COSTA 2 e STOP sono stati tutti collegati correttamente Qualora siano installate coste sensibili del tipo a gomma conduttiva l accensione contemporanea di entrambi i segmenti indica che l ingresso chiuso chiuso sulla resistenza nominale punti tra le cifre del display indicano lo stato dei pulsanti di programmazione quando si preme un tasto il relativo punto si accende Le frecce a sinistra del display indicano lo stato dei finecorsa Le frecce si accendono quando il relativo finecorsa indica che il cancello completamente chiuso o aperto Le frecce a destra del display indicano lo stato del cancello e La freccia pi in alto si accende quando il cancello in fase di apertura Se lampeggia indica che l apertura stata causata dall intervento di un dispositivo di sicurezza costa o rilevatore di ostacoli La freccia centrale indica che il cancello in pausa Se lampeggia si
41. OP Pros The input STOP stops the gate pressing the command START the gate continues the motion invE The command STOP stops the gate at the next START the gate starts moving in the opposite direction The setting of parameter STOP determines also in which direction the gate will move at the next START if it has stopped because of an intervention of the safety edges or the obstacle sensor NOTE during the pause the STOP command will stop the pause time count the next START command will always close the gate Photocell 1 input This menu allows enabling the input for type 1 photocells that is to say photocells active both during the opening and closing phase see paragraph Installation no input disabled ignored by the control unit No jumper with the common is required input enabled SEPE ENGLISH Photocell 2 input This menu allows enabling the input for type 2 photocells that is to say photocells non active during the opening phase see paragraph Installation no input disabled ignored by the control unit No jumper with the common is required input enabled even at standstill gate too the opening movement does not start if photocell is interrupted input enabled for the closing phase only Warning if you select this option you must disable photocell test Test of safety devices In order to achieve a safer operation for the user the unit performs a safety devices operational t
42. RT OUVERTURE une commande provoque l ouverture START P FERMETURE une commande provoque la fermeture La commande est de type impulsion c est dire que chaque impulsion provoque l ouverture ou la fermeture totale du portail Mode Homme mort START OUVERTURE une commande provoque l ouverture START P FERMETURE une commande provoque la fermeture Les commandes sont de type pression maintenue c est dire que le mouvement du portail s arr te d s que la commande est rel ch e Mode Horloge Cette fonction permet en utilisant une horloge de maintenir le portail ouvert certaine heure de la journ e START START une commande provoque l ouverture totale du portail START P START PIETONNE une commande provoque l ouverture partielle du portail Le portail reste ouvert tant que la commande est maintenue sur l entr e quand le contact s ouvre nouveau le d comptage du temps de pause commence puis le portail se referme Dans ce cas il est galement n cessaire d activer la refermeture automatique du portail Dans toutes les modalit s les entr es doivent entre branch es dispositifs avec contact normalement ouvert Brancher les c bles du dispositif que g re la entr e START entre les bornes P1 et P4 de l armoire Brancher les cables du dispositif que gere la entr e START P entre les bornes P2 et P4 de l armoire Il est possible activer la fonction associ e la entr e START e
43. SERVATO PER USI FUTURI A ATTENZIONE Per la programmazione dei 4 canali e delle logiche di funzionamento leggere attentamente le istruzioni allegate al ricevitore MR2 ANTENNA ESTERNA Si consiglia di utilizzare l antenna esterna modello ANS433 per garantire la massima portata radio Collegare il polo caldo dell antenna al morsetto A2 della centrale e la calza al morsetto A1 INTERFACCIA AN La centrale City6 dotata di interfaccia ADI Additional Devices Interface che permette il collegamento con una serie di moduli opzionali della linea V2 Fare riferimento al catalogo V2 per vedere quali moduli opzionali con interfaccia ADI sono disponibili per questa centrale A ATTENZIONE Per l installazione dei moduli opzionali leggere attentamente le istruzioni allegate ai singoli moduli RECEIVER TABELLA COLLEGAMENTI ELETTRICI Schermatura antenna Centrale antenna Comando di apertura per il collegamento di dispositivi tradizionali con contatto N A Comando di apertura pedonale per il collegamento di dispositivi tradizionali con contatto N A Comando di STOP Contatto N C Comune Fotocellula di tipo 1 Contatto N C Fotocellula di tipo 2 Contatto N C Coste di tipo 1 fisse Contatto N C Coste di tipo 2 mobili Contatto N C Comune Finecorsa in apertura Contatto N C Finecorsa in chiusura Contatto N C Uscita alimentazione 24VAC per fotocellule ed alt
44. V2 SPA Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY tel 39 01 72 81 2411 fax 39 01 72 84 050 info v2home com www v2home com IL n 228 1 EDIZ 15 04 2013 CITY6 CENTRALE DIGITALE PER IL COMANDO DI UN MOTORE TRIFASE DIGITAL CONTROL UNIT TO CONTROL A THREE PHASE MOTOR ARMOIRE DE COMMANDE NUMERIQUE D UN MOTEUR TRIPHASE CUADRO DE MANIOBRAS DIGITAL PARA EL MANDO DE UN MOTOR TRIF SICO INDICE AVVERTENZE IMPORTANTI CONFORMITA ALLE NORMATIVE CARATTERISTICHE TECNICHE DESCRIZIONE DELLA CENTRALE INSTALLAZIONE ALIMENTAZIONE E MOTORI LAMPEGGIATORE FOTOCELLULE ANTENNA INTERFACCIA ADI TABELLA COLLEGAMENTI ELETTRICI PANNELO DI CONTROLLO USO DEI TASTI DOWN MENU E UP PER LA PROGRAMMAZIONE CONFIGURAZIONE VELOCE CONFIGURAZIONE DELLA CENTRALE LETTURA DEL CONTATORE DI CICLI TABELLA FUNZIONI City6 ANOMALIE DI FUNZIONAMENTO ONVITVLI ITALIANO AVVERTENZE IMPORTANTI Per chiarimenti tecnici o problemi di installazione la V2 SPA dispone di un servizio di assistenza clienti attivo durante le ore di ufficio TEL 39 01 72 81 24 11 V2 SPA si riserva il diritto di apportare eventuali modifiche al prodotto senza preavviso inoltre declina ogni responsabilit per danni a persone o cose dovuti ad un uso improprio o ad un errata installazione A Leggere attentamente il seguente manuale di istruzioni prima di procedere con l installazione e la programmazione della centrale di comando e presente man
45. a solo dopo che stato rilevato il passaggio davanti ad entrambe Lampeggiatore in pausa Normalmente il lampeggiatore funziona solo durante il movimento del cancello Se questa funzione abilitata il lampeggiatore funziona anche durante il tempo di pausa Funzione degli ingressi di Start Questo men permette di scegliere la modalit di funzionamento degli ingressi vedere paragrafo INGRESSI DI ATTIVAZIONE APCH Modalit Apri Chiudi PrES Modalit Uomo Presente oroL Modalit Orologio StAn Modalit standard no Gli ingressi di Start da morsettiera sono disabilitati Gli ingressi radio funzionano secondo la modalit StAn Funzione freno Questo men permette di attivare la funzione freno grazie alla quale possibile impedire che un cancello pesante in seguito ad un comando o all intervento di una sicurezza a causa dell inerzia continui il movimento per qualche secondo invece di bloccarsi immediatamente A ATTENZIONE Se il motore dotato di freno elettromeccanico automatico questa funzione deve essere obbligatoriamente disabilitata Ingresso Stop Questo men permette di selezionare le funzioni associate al comando di STOP ProS Il comando di STOP ferma il cancello al successivo comando di START il cancello riprende il moto nella direzione precedente InvE Il comando di STOP ferma il cancello al successivo comando di START il cancello riprende il moto nella direzione opposta alla prec
46. a aparecer la voz t AP De esta forma se puede llegar r pidamente al final o al principio del listado Existen tres tipos de voces de menu Men de funci n Men de tiempo e Men de valor Programaci n de los men s de funci n Los men s de funci n permiten elegir una funci n entre un grupo de posibles opciones Cuando se entra en un men de funci n se visualiza la opci n activa en ese momento mediante las teclas DOWN y UP es posible desplazarse entre las opciones disponibles Pulsando la tecla MENU se activa la opci n visualizada y se vuelve al menu de configuraci n Programaci n de los menus de tiempo Los menus de tiempo permiten programar la durada de una funci n Cuando se entra en un men de tiempo se visualiza el valor programado en ese momento la modalidad de visualizaci n depende del valor programado Los tiempos inferiores al minuto se visualizan en este 4 8 8 8 Cada presi n de la tecla UP aumenta el tiempo programado de medio segundo cada presi n de la tecla DOWN lo disminuye de medio segundo Los tiempos incluidos entre 1 y 10 minutos se visualizan en este formato Cada presi n de la tecla UP aumenta el tiempo programado de 5 segundos cada presi n de la tecla DOWN lo disminuye de 5 segundos Los tiempos superiores a los 10 minutos se visualizan en este formato Cada presi n de la tecla UP aumenta el tiempo programado de medio minuto cada presi n de la tecla DOWN lo d
47. a richiusura automatica non attiva corrisponde al valore 0 0 5 20 0 Il cancello richiude dopo il tempo impostato Chiusura dopo il transito no Chiusura dopo il transito disabilitata carica Ch AU 0 5 20 0 Il cancello richiude dopo il tempo impostato no Si Pausa dopo il transito no Si Lampeggiatore in pausa Ingressi di start Modalit Apri Chiudi Modalit Uomo Presente Modalit Orologio Modalit standard Gli ingressi di Start da morsettiera sono disabilitati Funzione freno Ingresso di STOP Il comando di STOP ferma il cancello lo START successivo non inverte il moto Il comando di STOP ferma il cancello lo START successivo inverte il moto DISPLAY TABELLA FUNZIONI City6 DESCRIZIONI DEFAULT Fot 1 Ingresso FOTO 1 Funziona come fotocellula attiva in apertura e in chiusura Disabilitato Ingresso FOTO 2 Funziona come fotocellula attiva in chiusura e con cancello fermo Disabilitato Funziona come fotocellula attiva solo in chiusura Test dei dispositivi di sicurezza Funzione non attiva Test abilitato solo per le fotocellule Test abilitato solo per le coste di sicurezza Test abilitato sia per le fotocellule che per le coste di sicurezza Ingresso costa sensibile 1 costa fissa Ingresso disabilitato la ce
48. abilitate da men siano effettivamente installate Errore 9 Quando si cerca di modificare le impostazioni della centrale e sul display compare la scritta 8 8 8 8 Significa che la programmazione stata bloccata con la chiave di blocco programmazione cod CL1 necessario inserire la chiave nell apposito connettore OPTIONS prima di procedere con la modifica delle impostazioni Prelampeggio prolungato Quando viene dato un comando di start il lampeggiatore si accende immediatamente ma il cancello tarda ad aprirsi Significa che scaduto il conteggio di cicli impostato e la centrale richiede un intervento di manutenzione IMPORTANT REMARKS CONFORMITY TO REGULATIONS TECHNICAL SPECIFICATIONS DESCRIPTION OF THE CONTROL UNIT INSTALLATION PLUG IN RECEIVER EXTERNAL AERIAL ADI INTERFACE ELECTRIC CONNECTIONS TABLE CONTROL PANEL USE OF DOWN MENU AND UP KEYS FOR PROGRAMMING QUICK CONFIGURATION LOADING OF DEFAULT PARAMETERS READING OF CYCLE COUNTER City6 FUNCTION TABLE OPERATION DEFECTS HSITDN3I ENGLISH IMPORTANT REMARKS For any installation problems please contact V2 TEL 39 01 72 81 24 11 V2 has the right to modify the product without previous notice it also declines any responsibility to damage or injury to people or things caused by improper use or wrong installation A Please read this instruction manual very carefully before installing and programming your City6 control unit This instruc
49. abled to allow the gate release Connect the stop switch cables between terminal P3 and P4 of the control unit A ATTENTION If the STOP input is not used must be jumpered with the commands common line COM The stop switch function can be activated by means of a remote control stored on channel 3 see relevant instructions of MR2 receiver The led display above the P3 contact indicates the STOP entry status If the led display is on the contact is shut if it is off the contact is open 000 0000 00 ACTIVATION INPUTS START and START P City6 control unit is equipped with two activation inputs START and START P whose operation depends on the programmed operation modes see Strt item of programming menu e Standard mode START START a command will cause the complete opening of the gate START P PEDESTRIAN START a command will cause the partial opening of the gate Open Close command START OPENING always controls the gate opening START P CLOSING always controls the gate closing This is an impulse command that is to say that an impulse will cause the complete gate opening or closing Manned operation START OPENING always controls the gate opening START P CLOSING always controls the gate closing This is a monostable command that is to say the gate will be opened or closed as long as the contact is closed and it will immediately stop as the contact is open Timer mode This function
50. activ s par le mouvement des portails et ils indiquent a la centrale la position de compl te ouverture ou fermeture no les entr es des but es de fin de course sont d sactiv es Si les entr es des but es de fin de course sont activ es Anti patinage Quand une manceuvre d ouverture ou fermeture est emp ch e par un commande ou par intervention de la photocellule le temps tablit pour la manceuvre oppos e serait excessif pour cette raison l armoire actionne les moteurs seulement pour le temps n cessaire r cup rer l espace effectivement parcours Ceci ne pourrait pas tre suffisant surtout avec portails tr s lourds car cause de l inertie au moment de l inversion le portail parcoure encore un parcours en la direction initiale du quel l armoire n est pas en condition de n en tenir compte Si apr s un inversion le portail ne retourne pas au point de d part il est possible tablir un temps de antipatinage qu il est adjoint au temps calcul par l armoire pour r cup rer l inertie A ATTENTION Si la fonction ASM est des habilit e la manoeuvre de renversement continue jusqu quand le portail n est pas but e En cette phase l armoire n active pas le ralentissement avant d tre arriv joindre la but e et chaque obstacle rencontr apr s le renversement est consider fincourse Activation du capteur d obstacles Ce menu permet le r glage de la sensibilit du capteur d obstacles Lorsque le courant abso
51. ades instaladas en la puerta 3 Empezar el ciclo de autoaprendizaje voz APPr Esta ltima operaci n cierra el men de configuraci n y memoriza los par metros programados Procedimiento de autoaprendizaje e Si se han habilitado los finales de carrera o el detector de obst culos la puerta se activa en cierre hasta el tope o al llegar al final de carrera de cierre Si NO se han habilitado los finales de carrera o el detector de obst culos es necesario asegurarse de que cuando empieza el procedimiento la puerta est completamente cerrada La puerta se activa en apertura hasta el tope o al llegar al final de carrera de apertura Si los sensores no est n habilitados o no hay nada que sefiale la posici n al cuadro es necesario dar un comando de START cuando la puerta llega a la posici n de m xima apertura La puerta se activa en cierre hasta el tope o al llegar al final de carrera de cierre Si los sensores no est n habilitados o no hay nada que sefiale la posici n al cuadro es necesario dar un comando de START cuando la puerta llega a la posici n de cierre A ATENCI N al t rmino del ciclo de captura sobre la pantalla aparece por algunos instantes el valor m ximo de absorci n de corriente observada durante el ciclo con excepci n de las fases de arranque El instalador se puede basar en este dato para establecer el umbral del sensor de obst culos teniendo en cuenta que es necesario dejar un poco de m
52. allateur prendre en compte cette donn e pour tablir le seuil du capteur d obstacles en tenant compte qu il est n cessaire de laisser peu de marge pour viter que le moindre frottement ou rampage bloque le portail CONFIGURATION DE L ARMOIRE Dans ce paragraphe viens illustre pas pas la proc dure pour la configuration de tous les param tres de fonctionnement de l armoire City6 Il est possible faire une configuration compl te de l armoire suivant tout pas la proc dure ou s lectionner seulement les voix qu int ressent En tout cas pour rendre active la nouvelle configuration est indispensable ex cuter la proc dure correcte de sortie travers la voix FinE L armoire City6 est dou d une proc dure de auto apprentissage des temps de travail il est conseillable de faire l auto apprentissage et en suite changer les voix que ne vous satisfont SIVDNVYS CHARGEMENT DES PARAMETRES IMPLICITES En cas de besoin il est possible de remettre tous les param tres leur valeur standard ou implicite voir tableau r capitulatif la fin A ATTENTION Ce proc d cause la perte de tous les param tres personnalis s pourtant a t mis l ext rieur du menu de configuration pour minimiser le risque de l ex cuter par erreur 1 D brancher l armoire de commande 2 Re brancher le l affichage montre le test des segments Pendant que l affichage montre la r vision du firmware presser la touche UP l armoire visua
53. als P12 and P14 of the control unit e Connect receiver output of photocells 1 between terminals P4 and P5 of the control unit and receiver output of photocells 2 between terminals P4 and P6 of the control unit Use outputs having normally closed contact The led displays above the P5 and P6 contacts respectively show the entry status for type 1 and 2 photocells If the led display is on the contact is shut if it is off the contact is open A WARNING e if several couples of same kind photocells are mounted their outputs must be connected in series e n case of reflection photocells power supply must be connected to terminals P13 and P14 of the control unit to carry out the operation test 00000 00 0o00 Pu P1 P3 P4 P5 P6 P7 88 P9 P10 Pil P12 P13 gt s 2 gt lt 5 ah EL ed a B il a 3 3 LI SAFETY RIBBONS The control unit considers two kinds of safety ribbons depending on the terminal to which they are connected e Type 1 fixed they are mounted on walls or on other fixed obstacles that are approached by the gate during the opening phase When type 1 safety ribbons operate during the gate opening phase the control unit will close the gate for 3 seconds then it stands still when type 1 safety ribbons operate during the gate closing phase the control unit will stand still immediately The direction of the gate at next command of START or PEDESTRIAN START depends upon the par
54. ameter STOP it inverts or continues the motion Type 2 mobile they are mounted to the gate ends When type 2 safety ribbons operate during the gate opening phase the control unit will stand still immediately when type 2 safety ribbons operate during the gate closing the control unit will open the gate for 3 seconds then it will stand still The direction of the gate at next command of START or PEDESTRIAN START depends upon the parameter STOP it inverts or continues the motion Both entries can handle the classic edge with a contact normally shut and the conductive rubber edge with nominal 8 2 kOhm resistance Connect type 1 safety ribbons cables between terminals P7 P9 Connect type 2 safety ribbons cables between terminals P8 P9 In order to meet standard EN12978 requirements edges must be installed that are sensitive to conductive rubber the sensitive edges with a contact normally shut must be fitted with a power unit that constantly checks that everything is running smoothly If using control units suited to the test by power outage connect the power supply cables of the control unit between terminals P13 and P14 of the City6 Otherwise connect them between terminals P12 and P14 A WARNING When using more ribbons with N C contact the inputs have to be series connected If using more conductive rubbers the outputs have to be cascade connected and only the last one has to be terminated on the nominal resistance
55. anges which will get lost By holding down the DOWN key configuration menu items will scroll fast until item FinE is viewed Viceversa by holding down the UP key items will scroll fast backwards until item t AP is viewed In this way you can quickly reach either the top or bottom of the list There are the following three kinds of menu items e Function menu e Time menu e Value menu Function menu setup Function menus allow selecting a function from among a group of available options When you enter into a function menu the current active option will be viewed you can scroll all available options through DOWN and UP keys By pressing the MENU key you will activate the option viewed and you will return to the configuration menu Time menu setup Time menus allow setting a function duration When you enter into a time menu the current setup value will be viewed the display mode depends on the current value e Times being lower than one minute will be viewed as follows 9 8 8 8 each time you press UP key current time value increases of half a second vice versa each time you press the DOWN key current time value decreases of half a second e Times between 1 and 10 minutes will be viewed as follows 5 5 each time you press UP key current time value increases of 5 seconds vice versa each time you press the DOWN key current time value decreases of 5 seconds e Times being more than 10 minutes will be viewed
56. argen para evitar que el m nimo roce o tropiezo bloquee el cancel CONFIGURACION DEL CUADRO En este p rrafo se ilustra paso a paso el procedimiento para la configuraci n de todos los par metros de funcionamiento del cuadro City6 Es posible realizar una configuraci n completa del cuadro siguiendo todos los pasos del procedimiento o seleccionar solo las voces que interesan En ambos casos para que la nueva configuraci n quede programada es indispensable seguir el procedimiento correcto de salida mediante la voz FinE El cuadro City6 dispone de un procedimiento de autoaprendizaje de los tiempos de trabajo se aconseja por lo tanto programar inicialmente una configuraci n est ndar p rrafo anterior ejecutar el autoaprendizaje y posteriormente cambiar las voces que no satisfacen TONVdS3 ESPANOL CONFIGURACION PARAMETROS DE DEFAULT Si necesario es posible devolver todos los parametros a su valores estandar o de default ver tabla recapitulavia final A ATENCION Con esto procedimiento se pierden todos los parametros personalizados por eso se encuentra externo al menu de configuraci n para reducir el riesgo de ejecutarlo por error Desconectar el cuadro de maniobras Conectarlo de nuevo el display visualiza el test de los segmentos y despu s la revisi n del firmware por ejemplo Pr 1 2 Al visualizar la revisi n del firmware pulsar la tecla UP el cuadro visualiza una cuenta atr s de dE 9 a dE 1
57. ation si le segment vertical en haut est allum le contact est ferm si le segment vertical en bas est allum le contact est ouvert le dessin indiqu ci dessus illustre le cas o les entr es START START P PHOTO1 PHOTO2 COSTA1 COSTA2 et STOP ont t toutes raccord es correctement Si des barres palpeuses sensibles du type en caoutchouc conducteur sont install es l allumage simultan des deux segments indique que l entr e est ferm e sur la r sistance nominale Les points entre les chiffres de l afficheur indiquent l tat des boutons de programmation quand on presse une touche le point relatif s allume Les fl ches gauche de l afficheur indiquent l tat des but es de fin de course Les fl ches s allument quand la but e de fin de course relative indique que le portail est compl tement ferm ou ouvert Les fl ches droite de l afficheur indiquent l tat du portail e La fl che plus en haut s allume quand le portail est en phase d ouverture Si elle clignote elle indique que l ouverture a t caus e par l intervention d un dispositif de s ret barre palpeuse ou d tecteur d obstacles La fl che centrale indique que le portail est en tat de repos Si elle clignote cela signifie que le comptage du temps pour la fermeture automatique est actif La fl che plus en bas s allume quand le portail est en phase de fermeture Si elle clignote cela indique que la fermeture a t caus e par l inte
58. bre en el caso de ser activado Si el pulsador de stop viene activado mientras que la puerta est abierta autom ticamente queda deshabilitada la funci n de cierre autom tico para volver a cerrar la puerta es necesario dar un comando de start en el caso de que la funci n de start en pausa estuviera deshabilitada esta quedar a tempor neamente rehabilitada para permitir el desbloqueo de la puerta Conectar los cables del pulsador de stop entre los bornes P3 y P4 del cuadro AN ATENCI N Si no se utiliza la entrada STOP debe ser conectada con el com n de comandos COM La funci n del pulsador de stop tambi n puede ser activada mediante un emisor memorizado en el canal 3 ver las instrucciones del receptor MR2 El diodo luminoso sobre el contacto P3 indica el estado de entrada de STOP Si el diodo est encendido el contacto est cerrado si est apagado el contacto est abierto 000 0 000 00 ENTRADAS DE ACTIVACION DEL CUADRO START y START P El cuadro City6 dispone de dos entradas de activaci n START y START P Su funcionamiento depende de la modalidad programada Ver la voz S trt del men de programaci n Modalidad est ndar START START un comando provoca la apertura total de la puerta START P START PEATONAL un comando provoca la apertura parcial de la puerta Modalidad Abre Cierra START APERTURA manda siempre la apertura START P CIERRE manda siempre el cierre El comando es de
59. bstacle sensor bearing in mind that it is essential to leave a small margin to prevent even a minimum amount of friction or binding blocking the gate CONTROL UNIT CONFIGURATION This paragraph concerns the step by step procedure to set all operation parameters of City6 control unit You can either follow all procedure steps and perform a complete control unit configuration or select and adjust interesting items only As for both cases you will have to perform the right exit procedure through item FinE in order to activate your new configuration City6 control unit provides for a self learning procedure of working times therefore we recommend that you set up a standard configuration first see previous paragraph then you carry out the self learning and finally you change any unsatisfactory items INDE ENGLISH LOADING OF DEFAULT PARAMETERS If necessary it is possible to restore all the parameters to their standard or default value see table at the end A WARNING This procedure causes the loss of all the customized parameters therefore it has been put outside the configuration menu to reduce the possibility of executing it by mistake 1 Disconnect the control unit 2 Supply power the display shows the menu of the test of segments followed by the revision of the firmware e g Pr 1 2 3 While displayed the revision of the firmware press the key UP the control unit displays a countdown from dE 9 to dE 1
60. c intermittence interne Brancher les cables du clignotant aux bornes B1 et B2 de l armoire ee e PHOTOCELLULE Selon les bornes ou on branche les cellules l armoire le repartit en deux cat gories Le 230Vac 40W Photocellules type 1 sont install es sur la cot interne du portail et sont actives soit pendant l ouverture que la fermeture En cas d intervention des cellules type 1 l armoire arr te le portail quand le jet est d gag l armoire ouvre compl tement le portail Photocellules type 2 sont install es sue la cot externe du portail et sont actives seulement pendant la fermeture En cas d intervention de la cellule de type 2 l armoire re ouvre imm diatement le portail sans attendre le d brouillage L armoire City6 fournit une alimentation 24VAC pour les cellules et peut ex cuter un test du fonctionnement avant de commencer l ouverture du portail Les bornes d alimentation pour les Cellules sont prot g s par un fusible lectronique que coupe la courant en cas de surcharge Brancher les c bles d alimentation des metteurs des cellules entre les bornes P13 et P14 de la centrale Brancher les c bles d alimentation des r cepteurs des cellules entre Is bornes P12 et P14 de la centrale Brancher la sortie des r cepteurs des cellules de type 1 entre les bornes P4 et P5 de la centrale et la sortie des r cepteurs des cellules de type 2 entre les bornes P4 et P6 de la centrale Utiliser les sorties avec c
61. caoutchouc conducteur le test est effectu m me s il n a pas t activ par le menu test V rifier la connexion des barres palpeuses Erreur 9 Quand on essaye de modifier les tablissements de l armoire et sur l cran apparaitre l crite 8 8 8 8 Signifie que la programmation a t bloqu avec la cl de bloque programmation cod CL1 Pour proc der avec la modification des donn es c est n cessaire ins rer dans le connecteur interface ADI la m me cl utilis e pour activer le blocage de la programmation Clignotement pr alable prolong Quand on donne un commande de start le clignotant s allume imm diatement mais le portail ne s ouvre pas de suite Signifie qu il est termin le comptage des cycles tablit et l armoire n cessite d entretien INDICE ADVERTENCIAS IMPORTANTES CONFORMIDAD A LAS NORMATIVAS CARACTERISTICAS TECNICAS DESCRIPCION DEL CUADRO INSTALACION ALIMENTACION Y MOTOR LAMPARA DE SENALIZACION FOTOCELULAS BANDAS DE SEGURIDAD FINALES DE CARRERA ENTRADAS DE ACTIVACION DEL CUADRO RECEPTOR ENCHUFABLE ANTENA EXTERNA INTERFAZ ADI TABLA CONEXIONES ELECTRICAS PANEL DE CONTROL UTILIZACION DE LAS TECLAS DOWN MENU Y UP PARA LA PROGRAMACION CONFIGURACION RAPIDA CONFIGURACION DEL CUADRO CONFIGURACION PARAMETROS DE DEFAULT LECTURA DEL CONTADOR DE CICLOS TABLA DE FUNCION CITY6 ANOMALIAS DE FUNCIONAMIENTO TONVdS4 ESPANOL ADVERTENCIAS IMPORTANTES Por cualquier problema t
62. cerning the whole installation EEC Machine Directive 89 392 Annex IIA The automated vehicular gates shall comply with the following rules EN 12453 EN 12445 EN 12978 as well as any local rule in force Also the automation upstream electric system shall comply with the laws and rules in force and be carried out workmanlike The gate thrust force adjustment shall be measured by means of a proper tool and adjusted according to the max limits which EN 12453 allows We recommend to make use of an emergency button to be installed by the automation connected to the control unit STOP input so that the gate may be immediately stopped in case of danger Always remember to connect the earth according to current standards EN 60335 1 EN 60204 1 the City6 control unit has two specific W4 and W5 clamps Do not install the device outside CONFORMITY TO REGULATIONS V2 S p A hereby declare that CITY6 products conform to the essential requirements established in the following directives 89 336 CEE EMC Directive in accordance with standards EN 55014 1 EN 55014 2 EN 61000 3 2 61000 3 3 2006 95 CEE Low Voltage Directive in accordance with standards EN 60335 1 EN 60335 2 103 99 05 CEE Radio Directive in accordance with standard EN 301 489 3 Racconigi 12 11 2009 V2 SPA Jegal repreg ntative Cosir 6 De Fal a oO TECHNICAL SPECIFICATIONS 400V three phase 230V three Power supply phase 230V single phase
63. cli di apertura completati opzione tot della voce Cont Contatore a scalare dei cicli che mancano al prossimo intervento di manutenzione opzione SErv della voce Cont Questo secondo contatore pu essere programmato con il valore desiderato Lo schema di fianco illustra la procedura per leggere il totalizzatore leggere il numero di cicli mancanti al prossimo intervento di manutenzione e programmare il numero di cicli mancanti al prossimo intervento di manutenzione nell esempio la centrale ha completato 12451 cicli e mancano 1322 cicli al prossimo intervento L area 1 rappresenta la lettura del conteggio totale di cicli completati con i tasti Up e Down possibile alternare la visualizzazione delle migliaia o delle unit L area 2 rappresenta la lettura del numero di cicli mancanti al prossimo intervento di manutenzione il valore arrotondato alle centinaia L area 3 rappresenta l impostazione di quest ultimo contatore alla prima pressione del tasto Up o Down il valore attuale del contatore viene arrotondato alle migliaia ogni pressione successiva fa aumentare o diminuire l impostazione di 1000 unit Il conteggio precedentemente visualizzato viene perduto Segnalazione della necessit di manutenzione Quando il contatore dei cicli mancanti al prossimo intervento di manutenzione arriva a zero la centrale segnala la richiesta di manutenzione mediante un prelampeggio supplementare di 5 secondi La segnalazione vi
64. cording to the safety devices installed on the gate 3 Start the self learning cycle item APPr This last operation will close the configuration menu and store set up parameters Self learning procedure Incase the end of stroke or the obstacle sensor has been enabled the gate will be activated in closing direction until the stop end or the closing end of stroke is reached In case NEITHER the ends of stroke OR the obstacle sensor have been enabled be sure that the gate is completely closed when the procedure is started up The gate will be activated in opening direction until the stop end or the opening end of stroke is reached In case the sensors have not been enabled or if you realize that they do not signal the position to the control unit you must send a START command when the gate reaches its max opening position The gate will be activated in closing direction until the stop end or the closing end of stroke is reached In case the sensors have not been enabled or if you realize that they do not signal the position to the control unit you must send a START command must be sent when the gate reaches its fully closed position A IMPORTANT at the end of the learning cycle the level of current absorption peak measured during the cycle with the exception of the peak stages appears on the display for a few seconds The installer can work on the basis of this of information to establish the threshold of the o
65. da el comando de Start cierra la puerta si esta ha sido bloqueado por un comando de Stop o si no se ha habilitado el cierre autom tico TONVdS3 ESPANOL Start peatonal en apertura parcial Este menu permite establecer el comportamiento del cuadro si se recibe un comando de Start Peatonal durante la fase de apertura parcial PAUS La puerta se para y entra en pausa ChiU La puerta se vuelve a cerrar inmediatamente no La puerta continua a abrirse el comando no viene sentido A ATENCION Un comando de Start recibido en cualquier fase de la apertura parcial provoca una apertura total sin embargo un comando de Start Peatonal durante una apertura total no viene sentido Cierre autom tico En el funcionamiento autom tico el cuadro cierra autom ticamente despu s de un tiempo programado Si habilitado en el men St PA el comando de Start permite cerrar la puerta incluso antes del tiempo programado En el funcionamiento semiautom tico o sea si la funci n de cierre autom tico se deshabilita programando el valor cero el display visualiza no la puerta puede volver a cerrarse solo con el comando de Start en este caso la programaci n del men St PA no influye Si durante la pausa se recibe un comando de stop el cuadro pasa autom ticamente al funcionamiento semiautom tico Cierre despu s del transito En el funcionamiento autom tico cada vez que interviene una fotoc lula durante la pausa
66. e sensor When the power absorbed by the motor exceeds the level set an alarm goes off in the power unit If no is set the function is turned off Dynamic regulation of the obstacle sensor threshold sy activating this function the power unit automatically adjusts the obstacle sensor threshold to compensate the increased strain caused by aging mechanisms or the accumulation of debris In any case the threshold can be increased by a level that can exceed that set for the SEnS parameter by a maximum of 0 5A Allowance on the end stroke If installation requires the gate to seal against a mechanic end stroke bump either when opening or closing then you have to set an end stroke allowance time in which the obstacle sensor does not cause the safety withdrawal as a result of the bump against the stop but allows it to conclude the cycle If you set a margin higher than the work times any kind of obstacle sensor intervention will cause the interruption of the cycle If you set zero any intervention of the obstacle sensor will cause the gate to withdraw ANIRE ENGLISH Inversion time of the movement The inversion time is the time required to reverse the movement of the motor when a safety device is activated StAn standard inversion 250ms FASt fast inversion 140ms Counter viewing This menu allows viewing the counter of completed opening cycles and it also enables the final user to set up the times of ser
67. e imm diat du portail L interrupteur doit avoir un contact normalement ferm que s ouvre en cas d actionnement Si l interrupteur d arr te est actionn quand le portail est ouvert la fonction de re fermeture automatique viens toujours des habilit e pour refermer le portail il faut donner un commande de start si la fonction de start en pause est des habilit e viens provisoirement re habilit e pour permettre le d blocage du portail Brancher les cables de l interrupteur de stop entre les bornes P3 et P4 de l armoire AN ATTENTION L entr e STOP si non utilis e doivent tre shunt e avec le commun commandes COM La fonction de l interrupteur de stop peut tre activ e travers un metteur m moris sur le canal 3 voir les notices du r cepteur MR2 La DEL au dessus du contact P3 indique l tat de l entr e de STOP Si la DEL est allum e le contact est ferm si elle est teinte le contact est ouvert 000 0 000 00 P12 PM P1 L P3 P4 P5 P6 P7 P8 P9 PIO Pi PI hie AES TRE Buda ds ENTREES DE ACTIVATION START et START P L armoire City6 est dot e de deux entr es de commande START et START P dont la fonction d pend de la modalit de fonctionnement programm e Voir le Strt du menu programmation Mode standard START START une commande provoque l ouverture totale du portail START P 2 START PIETONNE une commande provoque l ouverture partielle du portail Mode Ouvre Ferme STA
68. e la borniere et v rifier que le led ne s allume nouveau Erreur 1 A la sortie de la programmation sur l cran apparaitre l crite 8 8 8 8 Signifie que n a pas t possible sauver les donn es modifi es Ce mal fonctionnement n est pas r parable par l installateur L armoire doit tre transmis V2 pour la r paration Erreur 3 Quand on donne un commande de start le portail ne s ouvre pas et sur l cran apparaitre l crite 8 6 6 8 Signifie que le test des photocellules a fallu S assurer que aucun obstacle a interrompu le faisceau des photocellules au moment qu on a donn le commande de start S assurer que les cellules habilit es par le menu soient effectivement install es S assurer que les cellules soient aliment es et fonctionnant en coupant le faisceau on doit se sentir le d clenchement du relai Erreur 4 Quand on donne un commande de start et le portail ne bouge pas ou s ouvre partiellement et sur l cran va appara tre 6 8 8 8 Signifie que le fin course est endommag ou le cablage entre le capteur et l armoire a t interrompu Remplacer le capteur fin course ou la partie du c blage endommag Si l erreur persiste envoyer l armoire V2 pour la r paration Erreur 5 Quand on donne un commande de start le portail ne s ouvre pas et sur l cran apparaitre l crite 6 8 8 8 Cela signifie que le test des barres palpeuses a chou si on utilise des barres palpeuses
69. e otro dispositivo montado sobre la l nea de alimentaci n Controlar si el fusible F3 est quemado En este caso sustituirlo con uno del mismo valor El led MAINS se enciende pero la pantalla no se enciende Significa que falta tensi n en el secundario del transformador 1 Antes de operar la central suprima la corriente mediante el seccionador montado en el cuadro o bien con otro dispositivo hacia la l nea de alimentaci n Controlar si el fusible F1 est quemado En este caso sustituirlo con uno del mismo valor Si la sustituci n del fusible no resuelve el problema env e el cuadro a la V2 para su reparaci n El led OVERLOAD est encendido Significa que hay una sobrecarga corto circuito en la alimentaci n de los accesorios Quitar la regleta que contiene los bornes entre N1 a N13 El led OVERLOAD se apaga Eliminar la causa de la sobrecarga Volver a poner la regleta de bornes y controlar que el led no se encienda de nuevo Error 1 A la salida de la programaci n en el display aparece la sigla 0 8 5 9 Significa que no ha sido posible guardar los datos modificados Este mal funcionamiento no puede ser solucionado por el instalador El cuadro tiene que ser enviado a V2 para su reparaci n Error 3 Cuando se da un comando de start la puerta no se abre y en el display aparece la sigla 6 6 0 9 Significa que ha fallado el test de las fotoc lulas 1 Asegurarse de que ning n obst culo haya interrum
70. e trabajo y de las l gicas de funcionamiento Respetando las normativas europeas en materia de seguridad el ctrica y compatibilidad electromagn tica EN 60335 1 EN 50081 1 y EN 50082 1 la City6 se caracteriza por el completo aislamiento el ctrico del circuito en baja tensi n incluyendo los motores de la tensi n de red Otras caracter sticas Detecci n de los obst culos mediante el monitoreo de la corriente absorbida de los motores Aprendizaje autom tico de los tiempos de trabajo Test de los dispositivos de seguridad fotoc lulas bandas de seguridad y triac antes de cada apertura Desactivaci n de las entradas de las seguridades mediante el men de programaci n no es necesario puentear los bornes referentes a la seguridad no instalada es suficiente deshabilitar la funci n en el menu correspondiente Posibilidad de bloquear el teclado de programaci n del cuadro de maniobras mediante la llave electr nica opcional CL1 Funci n de freno Posibilidad de operar motores de 400V trif sico 230V trif sico y 230V monof sico e Seccionador de seguridad El modelo CITY6 I est dotado tambi n de los siguientes pulsadores sobre la caja e Pulsador de APERTURA e Pulsador de CIERRE e Pulsador de STOP EMERGENCIA INSTALACION La instalaci n del cuadro de los dispositivos de seguridad y de los accesorios tiene que hacerse con la alimentaci n desconectada ALIMENTACI N Y MOTORES El cuadro de mani
71. edente L impostazione del parametro STOP determina anche la direzione del moto del cancello fermo dopo l intervento delle coste sensibili o del sensore di ostacoli in seguito ad un comando di START Se si imposta no il comando di START fa riprendere il moto nella stessa direzione NOTA durante la pausa il comando di STOP ferma il conteggio del tempo di pausa il successivo comando di START richiuder sempre il cancello Ingresso foto 1 Questo men permette di abilitare l ingresso per le fotocellule di tipo 1 cio attive in apertura e in chiusura vedere il paragrafo installazione no Ingresso disabilitato la centrale lo ignora Non necessario ponticellare con il comune AP CH Ingresso abilitato ONVITVLI ITALIANO Ingresso foto 2 Questo men permette di abilitare l ingresso per le fotocellule di tipo 2 cio non attive in apertura vedere il paragrafo installazione no Ingresso disabilitato la centrale lo ignora Non necessario ponticellare con il comune Ingresso abilitato anche a cancello fermo la manovra di apertura non inizia se la fotocellula interrotta Ingresso abilitato solo in chiusura ATTENZIONE se si sceglie questa opzione necessario disabilitare il test delle fotocellule Test dei dispositivi di sicurezza Per garantire una maggior sicurezza per l utente la centrale opera prima che inizi ogni ciclo di operazione normale un test di funzionamento sui d
72. end of stroke sensor or the broken wiring If the error persists send the control unit to V2 for repair Error 5 When a Start command is given the gate does not open and the following writing appears on display 6 8 8 8 It means that the safety edge test failed if using conductive rubbers the test is carried out also if not activated by test menu Check the connection of the safety edges Error 9 When you are trying to change the control unit setups and the following writing appears on display 8 8 8 8 It means that programming was locked by means of the programming lock key code CL1 To change the settings it is necessary to insert in the connector of the ADI interface the same key used to activate the programming lock Too long pre blinking When a Start command is given and the blinker switches on immediately but the gate is late in opening it means that the setup cycle count down expired and the control unit shows that service is required CONSEILS IMPORTANTS CONFORMITE AUX NORMATIFS CARACTERISTIQUES TECHNIQUES DESCRIPTION DE LA CENTRALE INSTALLATION INTERFACE ADI TABLEAU BRANCHEMENTS ELECTRIQUES PANNEAU DE CONTROLE EMPLI DES TOUCHES DOWN ET UP POUR LA PROGRAMMATION CONFIGURATION RAPIDE CONFIGURATION DE L ARMOIRE CHARGEMENT DES PARAMETRES IMPLICITES LECTURE DU COMPTEURS DE CYCLES TABLEAU FONCTIONS City6 ANOMALIE DE FONCTIONNEMENT SIVDNVYS FRANCAIS CONSEILS IMPORTANTS Pour tout pr cisi
73. ene ripetuta all inizio di ogni ciclo di apertura finch l installatore non accede al menu di lettura e impostazione del contatore programmando eventualmente il numero di cicli dopo il quale sar nuovamente richiesta la manutenzione Se non viene impostato un nuovo valore cio il contatore viene lasciato a zero la funzione di segnalazione della richiesta di manutenzione disabilitata e la segnalazione non viene pi ripetuta A ATTENZIONE le operazioni di manutenzione devono essere eseguite esclusivamente da personale qualificato ONVITVLI ITALIANO DISPLAY DATI TABELLA FUNZIONI City6 DESCRIZIONI DEFAULT 0 0 5 0 Tempo apertura 15 0 0 0 t AP1 Tempo apertura pedonale 6 0 0 0 5 0 Tempo chiusura 16 0 0 0 t Ch Tempo chiusura pedonale 7 0 0 5 1 0 Tempo prelampeggio 1 0 no Prelampeggio disabilitato corrisponde al valore 0 Start in apertura comando START non sentito Il cancello richiude Il cancello va in pausa Start in chiusura Il cancello conclude il ciclo Il cancello riapre Start in pausa Il comando di START non sentito Il cancello richiude Start pedonale in apertura Il comando di START P non sentito Il cancello richiude Il cancello va in pausa Richiusura automatica no L
74. ening has been caused by a safety device border or obstacle detector e The central arrow shows that the gate is on pause If it blinks it means that the time countdown for the automatic closing has been activated The lowest arrow blinks when the gate is into its closing phase If it blinks it means that the closing has been caused by a safety device border or obstacle detector USE OF DOWN MENU AND UP KEYS FOR PROGRAMMING Control unit time and function programming is made within a special configuration menu to which you can access and where you can shift through DOWN MENU and UP keys placed under the display Hold down the MENU key until t AP appears on display to activate the programming mode while display views the panel Configuration menu consists of a list of configurable items the wording appearing on display will show the current selected item By pressing DOWN you will pass to the next item by pressing UP you will return to the previous item By pressing MENU you can view the current value of selected item and possibly change it The last menu item FinE allows storing the carried out changes and going back to the control unit normal operation You must exit from programming mode through this menu item if you do not want to lose your configuration A WARNING in case no operation is carried out for more than one minute the control unit exits from the programming mode without saving any of your setups and ch
75. er of cycles before the next request for service as for the example shown the control unit completed no 12451 cycles and there are no 1322 cycles before the next service request Area 1 is the reading of the total number of completed cycles through Up and Down keys you can alternate the display of thousands or units Area 2 is the reading of the number of cycles before the next request for service its value is rounded down to the hundreds Area 3 is the setup of this latter counter if you press once UP or DOWN key the current counter value will be rounded up or down to thousands any following pressure will have the setup be increased or decreased of 1000 units The previous displayed count will get lost Signal of service required As soon as the counter of cycles before the next request for service is zero the control unit shows the request for service through an additional 5 second pre blinking This signal will be repeated at each opening cycle until the installer enters into the counter reading and setup menu and possibly programs the number of cycles after which the next service will be requested In case no new value is setup that is to say that the counter value is left at zero the signalling function for the service request will be disabled and no signal will be repeated anymore A WARNING service operations shall be carried out by qualified staff only AINE ENGLISH DISPLAY D
76. erita all esterno del menu di configurazione per minimizzare la probabilit che venga eseguita per sbaglio 1 Togliere l alimentazione della centrale 2 Ripristinare l alimentazione sul display appare la videata di test dei segmenti seguita dalla revisione firmware esempio Pr 1 2 Mentre visualizzata la revisione del firmware premere il tasto UP la centrale visualizza un conto alla rovescia da dE 9 a dE 1 Prima che il conto alla rovescia si esaurisca premere il tasto MENU tutti i parametri vengono riscritti con il loro valore di default e viene avviato il menu di configurazione in modo da poter effettuare subito le modifiche necessarie Qualora si fosse avviata la procedura di caricamento dei parametri di default per errore sufficiente lasciar scadere il conto alla rovescia La centrale riprender il funzionamento normale senza modificare i parametri impostati Tempo di apertura In apertura il motore viene azionato per il tempo impostato la centrale pu interrompere l apertura prima dell esaurimento del tempo se viene rilevato un ostacolo o se interviene il fine corsa Tempo di apertura parziale accesso pedonale Se viene ricevuto un comando di Start Pedonale la centrale apre il cancello per un tempo ridotto Il massimo tempo impostabile t AP Tempo di chiusura In chiusura il motore viene azionato per il tempo impostato la centrale pud interrompere l apertura prima dell esaurimento de
77. est before a normal working cycle If no operational faults are found the gate starts moving Otherwise it will stand still and the flashing light will stay onfor 5 sec The whole test cycle lasts less than one second no function not active Foto test enabled only for photocells CoSt test enabled only for safety edges Ft Co test enabled either for photocells or for safety edges A WARNING e f you use conductive rubber edges DO NOT activate the functioning test for the edge The test on edges with contact normally shut is only possible if a power unit specifically for this use has been installed The Test of safety devices should be working in order to grant more safety during installation and programming Safety ribbon 1 input This menu allows enabling the input for type 1 safety ribbon that is to say fixed ribbons see paragraph Installation no Input disabled ignored by the control unit No jumper with the common is required input enabled for standard safety ribbons with n c contact input enabled for conductive rubber safety ribbons with nominal resistance 8 2 kohm Safety ribbon 2 input This menu allows enabling the input for type 2 safety ribbon that is to say mobile ribbons see paragraph Installation no Input disabled ignored by the control unit No jumper with the common is required input enabled for standard safety ribbons with n c contact input enabled for conductive rubber safety ribbons with no
78. ey Brake function Possibility of piloting 400V three phase 230V three phase and 230V single phase motors Safety disconnecting switch The model CITY6 I is also equipped with the following switches placed on the box e OPENING switch CLOSURE switch STOP switch EMERGENCY INSTALLATION Installation of control unit and safety devices must be carried out with power disconnected POWER SUPPLY AND MOTORS The control unit must be powered by an electric wire protected by a differential magnetothermic switch in compliance with current legislation The power needed depends on the kind of motor used and can be one of three kinds e 400V three phase e 230V three phase e 230V single phase The following layouts show how the power and cables on the motor should be connected and how the voltage selection connector in each case should be set up A IMPORTANT before connecting the power supply make sure the voltage selection connector has been properly set up Incorrect setting could seriously damage the control unit 400V three phase 230Voc 40W 230V three phase compared to the previous layout only the voltage selection connector changes 230V Single phase in this case you have to fit a starter condenser 82 LRH 230Voc 40W Use the W4 and W5 clamps for the earth connection of the motors to the system s earth If the directional movement of the gate is the opposite to the o
79. eza el ciclo de aprendizaje A ATENCION El procedimiento de aprendizaje automatico de los tiempos de trabajo NO se puede empezar si el cuadro esta programado en modalidad HOMBRE PRESENTE Pr ES Fin Programacion Este men permite terminar la programaci n ya sea por defecto o personalizada grabando en memoria los datos modificados no ulteriores modificaciones a efectuar no salir de la programaci n Si modificaciones terminadas fin programaci n LOS DATOS PROGRAMADOS HAN SIDO GRABADOS EN MEMORIA EL CUADRO DE MANIOBRAS EST AHORA LISTO PARA SU UTILIZACI N LECTURA DEL CONTADOR DE CICLOS El cuadro City6 cuenta los ciclos de apertura de la puerta completados y si se quiere se ala la necesidad de mantenimiento despu s de un n mero establecido de maniobras Se dispone de dos tipos de contadores Totalizador no reseteable de los ciclos de apertura completados opci n tot del men Cont Cuenta atr s de los ciclos que faltan para la pr xima intervenci n de mantenimiento opci n SErv del men Cont Este segundo contador puede programarse con el valor que se desee El esquema de al lado ilustra el procedimiento para leer el totalizador leer el numero de ciclos que faltan para la pr xima intervenci n de mantenimiento y programar el n mero de ciclos que faltan para la pr xima intervenci n de mantenimiento en el ejemplo el cuadro ha completado 12451 ciclos y faltan 1322 ciclos a la pr xima intervenci
80. gliere l opzione StoP Per impostare la logica di funzionamento apre sempre scegliere l opzione APEr Start in pausa Questo men permette di stabilire il comportamento della centrale se viene ricevuto un comando di Start mentre il cancello aperto in pausa ChiU Il cancello inizia a richiudersi no Il comando viene ignorato Per impostare la logica di funzionamento passo passo scegliere l opzione ChiU Per impostare la logica di funzionamento apre sempre scegliere l opzione no Indipendentemente dall opzione scelta il comando di Start fa richiudere il cancello se questo stato bloccato con un comando di Stop o se non abilitata la richiusura automatica ONVITVLI ITALIANO Start pedonale in apertura parziale Questo menu permette di stabilire il comportamento della centrale se viene ricevuto un comando di Start Pedonale durante la fase di apertura parziale PAUS I cancello si ferma ed entra in pausa ChiU Il cancello inizia immediatamente a richiudersi no Il cancello continua ad aprirsi il comando viene ignorato A ATTENZIONE Un comando di Start ricevuto in qualunque fase dell apertura parziale provoca un apertura totale il comando di Start Pedonale viene sempre ignorato durante un apertura totale Chiusura automatica Nel funzionamento automatico la centrale richiude automaticamente il cancello allo scadere di un tempo prefissato Se abilitato dal menu St PA i
81. gnifica che attivo il conteggio del tempo per la chiusura automatica La freccia pi in basso si accende quando il cancello in fase di chiusura Se lampeggia indica che la chiusura stata causata dall intervento di un dispositivo di sicurezza costa o rilevatore di ostacoli USO DEI TASTI DOWN MENU E UP PER LA PROGRAMMAZIONE La programmazione delle funzioni e dei tempi della centrale viene fatta in un apposito menu di configurazione a cui si accede e in cui ci si muove per mezzo dei tasti DOWN MENU e UP posti al di sotto del display Per attivare la modalit di programmazione mentre il display visualizza il pannello di controllo tenere premuto il tasto MENU finch sul display non compare la scritta t AP Il menu di configurazione consiste in una lista di voci configurabili la sigla che compare sul display indica la voce attualmente selezionata Premendo il tasto DOWN si passa alla voce successiva premendo il tasto UP si ritorna alla voce precedente Premendo il tasto MENU si visualizza il valore attuale della voce selezionata e si pu eventualmente modificarlo L ultima voce di menu FinE permette di memorizzare le modifiche effettuate e tornare al funzionamento normale della centrale Per non perdere la propria configurazione obbligatorio uscire dalla modalit di programmazione attraverso questa voce del menu A ATTENZIONE se non si effettua alcuna operazione per piu di un minuto la centrale esce dalla modalita di
82. gono elencate alcune anomalie di funzionamento che si possono presentare ne viene indicata la causa e la procedura per porvi rimedio Il led MAINS non si accende Significa che manca tensione sulla scheda della centrale City6 1 Assicurarsi che non vi sia un interruzione di tensione a monte della centrale e che il sezionatore sia su ON 2 Prima di agire sulla centrale togliere corrente tramite il sezionatore montato sulla centrale o altro dispositivo a monte sulla linea di alimentazione Controllare se il fusibile F3 bruciato In questo caso sostituirlo con uno di pari valore Il led MAINS acceso ma il display non si accende Significa che manca tensione sul secondario del trasformatore 1 Prima di agire sulla centrale togliere corrente tramite il sezionatore montato sulla centrale o altro dispositivo a monte sulla linea di alimentazione 2 Controllare se il fusibile F1 amp bruciato In questo caso sostituirlo con uno di pari valore 3 Se la sostituzione del fusibile non risolve il problema inviare la centrale alla V2 per la riparazione Il led OVERLOAD acceso Significa che presente un sovraccarico sull alimentazione degli accessori Rimuovere la parte estraibile contenente i morsetti da 12 a 21 Il led OVERLOAD si spegne Eliminare la causa del sovraccarico Reinnestare la parte estraibile della morsettiera e verificare che il led non si accenda nuovamente Errore 1 All uscita dalla programmazione s
83. gressif des cycles que manquent la prochaine entretien option Serv de la voix Cont Ce deuxi me compteur peut tre programm avec le valeur souhait Le sch ma cot montre la proc dure pour lire le totalisateur lire le nombre de cycle manquant la prochaine entretien et programmer le nombre de cycle manquant la prochaine entretien dans l exemple l armoire a compl t 12451 cycles et manquent 1322 cycles a la prochaine entretien L aire 1 repr sente la lecture du compte totale des cycles compl t avec les touches Up et Down est possible alterner la visualisation des milliers ou des unit s L aire 2 repr sente la lecture du nombre des cycles manquants la prochaine entretien le valeur est arrondi la centaine L aire 3 repr sente l tablissement de ce dernier compteurs la premiers pression du touche Up ou Down le valeur actuel du compteur viens arrondi au millier chaque pression apr s augmente ou diminue le postage de 1000 unit Le comptage pr c demment visualis est perdu Signalisation de la n cessit d entretien Quand le compteur des cycles manquant la prochaine entretien arrive z ro l armoire signale la requ te d entretien travers un clignotement pr alable suppl mentaire de 5 seconds La signalisation viens r p t au d but de chaque cycle d ouverture jusqu quand l installateur n acc de au menu de lecture et tablissement du compteur en programmant vent
84. i pressione del tasto UP fa aumentare il tempo impostato di 5 secondi ogni pressione del tasto down lo fa diminuire di 5 secondi e tempi superiori ai 10 minuti vengono visualizzati in questo formato Ogni pressione del tasto UP fa aumentare il tempo impostato di mezzo minuto ogni pressione del tasto down lo fa diminuire di mezzo minuto Tenendo premuto il tasto UP si pu aumentare velocemente il valore di tempo fino a raggiungere il massimo previsto per questa voce Analogamente tenendo premuto il tasto DOWN si pu diminuire velocemente il tempo fino a raggiungere il valore 0 0 In alcuni casi l impostazione del valore 0 equivale alla disabilitazione della funzione in questo caso invece del valore 0 0 viene visualizzato no Premendo il tasto MENU si conferma il valore visualizzato e si ritorna al menu di configurazione Impostazione dei menu di valore menu di valore sono analoghi ai menu di tempo ma il valore impostato un numero qualsiasi Tenendo premuto il tasto UP o il tasto DOWN il valore aumenta o diminuisce lentamente CONFIGURAZIONE VELOCE In questo paragrafo viene illustrata una procedura veloce per configurare la centrale e metterla immediatamente in opera Si consiglia di seguire inizialmente queste istruzioni per verificare velocemente il corretto funzionamento della centrale del motore e degli accessori e successivamente modificare la configurazione se qualche parametro non fosse soddisfacente Per
85. installare coste sensibili a gomma conduttiva le coste sensibili con contatto normalmente chiuso devono essere dotate di una centralina che ne verifichi costantemente la corretta funzionalit Se si utilizzano centraline che hanno la possibilit di eseguire il test mediante interruzione dell alimentazione collegare i cavi di alimentazione della centralina tra i morsetti P13 e P13 della City6 In caso contrario collegarli tra i morsetti P12 e P14 A ATTENZIONE e Se si utilizzano pi coste con contatto normalmente chiuso le uscite devono essere collegate in serie Se si utilizzano pi coste a gomma conduttiva le uscite devono essere collegate in cascata e solo l ultima deve essere terminata sulla resistenza nominale led sopra i contatti P7 e P8 indicano rispettivamente lo stato degli ingressi per costa sensibile di tipo 1 e 2 Fare riferimento alla tabella seguente per determinare lo stato in base al tipo di costa installata Costa tradizionale Costa gomma conduttiva Led rosso e verde Contatto aperto Contatto aperto spenti allarme allarme Led rosso acceso Contatto chiuso ok Costa schiacciata Led verde spento allarme Led rosso e verde Resistenza nominale accesi ok FINE CORSA La centrale City6 supporta un fine corsa con interruttore normalmente chiuso che viene aperto quando il cancello raggiunge la posizione desiderata fine corsa devono essere collegati alla morsettiera della centrale come segue Fi
86. iona los motores solo por el tiempo necesario para recuperar el espacio realmente recorrido Este podr a no ser suficiente sobre todo para puertas muy pesadas puesto que a causa de la inercia en el momento de la inversi n la puerta todav a recorre un trozo en la direcci n inicial del que el cuadro no puede percatarse Si despu s de una inversi n la puerta no vuelve exactamente al punto inicial de salida es posible programar un tiempo de antipatinamiento que se a ade al tiempo calculado por el cuadro para recuperar la inercia A ATENCION Si la funci n ASM est deshabilitada la maniobra de inversi n sigue hasta que la puerta llegue al tope o al final de carrera En esta fase el cuadro no activa el paro suave antes de llegar a los topes y cualquier obst culo encontrado despu s de la inversi n se considera como final de carrera Habilitaci n del sensor de obst culos Este men permite la regulaci n de la sensibilidad del sensor de obst culos Cuando la corriente que absorbe el motor supera el valor programado el cuadro observa una alarma Si se programa no la funci n se inhabilita Regulaci n din mica del umbral del sensor de obst culos Habilitando esta funci n el cuadro modifica autom ticamente el umbral del sensor de obst culos para compensar el aumento en el esfuerzo causado por el envejecimiento de los mecanismos o la acumulaci n de escombros En todo caso el umbral se puede aumentar desde un valor que puede
87. isminuye de medio minuto Manteniendo pulsada la tecla UP se puede aumentar r pidamente el valor del tiempo hasta conseguir el m ximo previsto para esa voz De la misma forma manteniendo pulsada la tecla DOWN se puede disminuir r pidamente el tiempo hasta llegar al valor 0 0 En algunos casos la programaci n del valor 0 equivale a la deshabilitaci n de la funci n en este caso en lugar del valor 0 0 se visualiza no Pulsando la tecla MENU se confirma el valor visualizado y se vuelve al men de configuraci n Programaci n de los menus de valor Los menus de valor son como los menus de tiempo pero el valor programado es un n mero cualquiera Manteniendo pulsada la tecla UP o la tecla DOWN el valor aumenta o disminuye lentamente CONFIGURACION RAPIDA En este p rrafo se ilustra un procedimiento r pido para configurar el cuadro y ponerlo en marcha inmediatamente Se aconseja seguir inicialmente estas instrucciones para verificar r pidamente el correcto funcionamiento del cuadro del motor y de los accesorios y posteriormente modificar la configuraci n si alg n par metro no satisface Para la posici n de la voces en el interior del men e para las opciones disponibles para cada voz hacer referencia al p rrafo Configuraci n del cuadro 1 Seleccionar una configuraci n por defecto ver p rrafo CONFIGURACI N PAR METROS DE DEFAULT 2 Programar las voces StoP Foto CoSt y FC En en funci n de las segurid
88. ispositivi di sicurezza Se non ci sono anomalie funzionali il cancello entra in movimento In caso contrario resta fermo e il lampeggiante si accende per 5 secondi Tutto il ciclo di test dura meno di un secondo no Funzione non attiva Foto Test abilitato solo per le fotocellule Cost Test abilitato solo per le coste di sicurezza Ft Co Test abilitato sia per le fotocellule che per le coste di sicurezza A ATTENZIONE Se si utilizzano coste a gomma conduttiva NON attivare il test di funzionamento per la costa Il test delle coste con contatto normalmente chiuso possibile solo se installata una centralina predisposta per questa funzione V2 consiglia di mantenere attivo il Test dei dispositivi di sicurezza al fine di garantire una maggior sicurezza del sistema Ingresso Costa Sensibile 1 Questo men permette di abilitare l ingresso per le coste sensibili di tipo 1 cio fisse vedere il paragrafo installazione no Ingresso disabilitato la centrale lo ignora Non necessario ponticellare con il comune Ingresso abilitato per coste sensibili standard con contatto normalmente chiuso Ingresso abilitato per le coste a gomma conduttiva con resistenza nominale 8 2 kohm Ingresso Costa Sensibile 2 Questo men permette di abilitare l ingresso per le coste sensibili di tipo 2 cio mobili vedere il paragrafo installazione no Ingresso disabilitato la centrale lo ignora Non necessario ponticellare con il comune Ingress
89. izaci n a 230V 40W con intermitencia interna Conectar los cables de la l mpara de se alizaci n entre los bornes B1 y B2 del cuadro dj W4 w5 La FOTOCELULAS Seg n el borne donde est n conectadas el cuadro divide las fotoc lulas en dos categor as Fotoc lulas del tipo 1 se instalan en el lado interior de la puerta y se activan tanto en apertura como en cierre En caso de intervenci n de las fotoc lulas del tipo 1 el cuadro para la puerta cuando estas dejan de intervenir el cuadro abre completamente la puerta Fotoc lulas del tipo 2 se instalan en el lado externo de la puerta y se activan solo durante el cierre En caso de intervenci n de las fotoc lulas del tipo 2 el cuadro vuelve a abrir inmediatamente la puerta sin esperar que estas dejen de intervenir El cuadro City6 tiene una salida de 24VAC para las fotoc lulas y puede efectuar un test sobre su funcionamiento antes de empezar la apertura la puerta Los bornes de alimentaci n para las fotoc lulas est n protegidos por un fusible electr nico que interrumpe la corriente en caso de sobrecarga o cortocircuito Conectar los cables de alimentaci n de los emisores de las fotoc lulas entre los bornes P13 y P14 del cuadro Conectar los cables de alimentaci n de los receptores de las fotoc lulas entre los bornes P12 y P14 del cuadro Conectar la salida de los receptores de las fotoc lulas del tipo 1 entre los bornes P4 y P5 del c
90. l comando di Start permette di chiudere il cancello anche prima dello scadere del tempo impostato Nel funzionamento semiautomatico cio se la funzione di chiusura automatica viene disabilitata portando il valore a zero il display visualizza no il cancello pu essere richiuso solo con il comando di Start in questo caso l impostazione del menu St PA viene ignorata Se durante la pausa viene ricevuto un comando di stop la centrale passa automaticamente al funzionamento semiautomatico Chiusura dopo il transito Nel funzionamento automatico ogni volta che interviene una fotocellula durante la pausa il conteggio del tempo di pausa ricomincia dal valore impostato in questo menu Analogamente se la fotocellula interviene durante l apertura viene immediatamente caricato questo tempo come tempo di pausa Questa funzione permette di avere una rapida chiusura dopo il transito attraverso il cancello per cui solitamente si utilizza un tempo inferiore a CH AU Se si imposta no viene utilizzato il tempo Ch AU Nel funzionamento semiautomatico questa funzione non attiva Pausa dopo il transito Per rendere minimo il tempo in cui il cancello rimane aperto possibile fare in modo che il cancello si fermi non appena viene rilevato il passaggio davanti alle fotocellule Se abilitato il funzionamento automatico come tempo di pausa viene caricato il valore Ch tr Se sono installate fotocellule sia di tipo 1 sia di tipo 2 il cancello va in paus
91. l tempo se viene rilevato un ostacolo o se interviene il fine corsa Per evitare che il cancello non si chiuda completamente consigliabile impostare un tempo pi lungo di quello di apertura t AP Tempo di chiusura parziale accesso pedonale In caso di apertura parziale la centrale usa questo tempo per la chiusura Il massimo tempo impostabile t CH Per evitare che il cancello non si chiuda completamente consigliabile impostare un tempo pi lungo di quello di apertura t APP Tempo prelampeggio Prima di ogni movimento del cancello il lampeggiatore viene attivato per il tempo t PrE per segnalare l imminente manovra Start in apertura Questo menu permette di stabilire il comportamento della centrale se viene ricevuto un comando di Start durante la fase di apertura PAUS Il cancello si ferma ed entra in pausa ChiU Il cancello inizia immediatamente a richiudersi no Il cancello continua ad aprirsi il comando viene ignorato Per impostare la logica di funzionamento passo passo scegliere l opzione PAUS Per impostare la logica di funzionamento apre sempre scegliere l opzione no Start in chiusura Questo men permette di stabilire il comportamento della centrale se viene ricevuto un comando di Start durante la fase di chiusura StoP I cancello si ferma e il ciclo viene considerato concluso APEr l cancello si riapre Per impostare la logica di funzionamento passo passo sce
92. la posizione delle voci all interno del menu e per le opzioni disponibili per ciascuna voce fare riferimento al paragrafo Configurazione della centrale 1 Richiamare una configurazione di default vedi paragrafo CARICAMENTO PARAMETRI DI DEFAUL 2 Impostare le voci StoP Foto CoSt e FC En in base alle sicurezze installate sul cancello 3 Awiare il ciclo di autoapprendimento voce APPr Quest ultima operazione chiude il menu di configurazione e memorizza i parametri impostati Procedura di autoapprendimento e Se sono stati abilitati i finecorsa o il sensore di ostacoli il cancello viene attivato in chiusura fino a battuta o al raggiungimento del finecorsa di chiusura Se NON sono stati abilitati i finecorsa o il sensore di ostacoli occorre assicurarsi che quando la procedura viene avviata il cancello sia completamente chiuso Il cancello viene attivato in apertura fino a battuta o al raggiungimento del finecorsa di apertura Se i sensori non sono abilitati o se si verifica che non segnalano alla centrale la posizione occorre dare un comando di START quando il cancello ha raggiunto la posizione di massima apertura Il cancello viene attivato in chiusura fino a battuta o al raggiungimento del finecorsa di chiusura Se i sensori non sono abilitati o se si verifica che non segnalano alla centrale la posizione occorre dare un comando di START quando il cancello ha raggiunto la posizione di chiusura A ATTENZIO
93. les de tensi n de red y a los de las conexiones de las partes externas accesorios respetivamente en proximidad de la regleta De esta forma se evita en el caso de una desconexi n accidental de un cable que las partes con tensi n de red entren en contacto con las partes en baja tensi n de seguridad Para la conexi n de tubos r gidos o flexibles y pasacables utilizar manguitos conformes al grado de protecci n IP55 como la caja de pl stico que contiene la placa La instalaci n requiere competencias en el campo el ctrico y mec nico debe ser realizada nicamente por personal cualificado en grado de expedir la declaraci n de conformidad en la instalaci n Directiva m quinas 89 392 CEE anexo IIA Es obligatorio atenerse a las siguientes normas para cierres automatizados con paso de veh culos EN 12453 EN 12445 EN 12978 y a las eventuales prescripciones nacionales Incluso la instalaci n el ctrica antes de la automatizaci n debe responder a las vigentes normativas y estar realizada correctamente La regulaci n de la fuerza de empuje de la puerta debe medirse con un instrumento adecuado y regulada de acuerdo con los valores m ximos admitidos por la normativa EN 12453 Aconsejamos utilizar un pulsador de emergencia e instalarlo en proximidad a la automatizaci n conectado a la entrada STOP de la placa de comando de modo que sea posible el paro inmediato de la puerta en caso de peligro Conectar el cable de tierra de l
94. lise un compte rebours de dE 9 dE 1 Avant que le compte rebours termine presser la touche MENU tous les param tres sont r crits avec leur valeur implicite et le menu de configuration est lanc pour permettre d effectuer les modifications n cessaires Dans le cas o le proc d de chargement des param tres implicites a t lanc par erreur il suffit de laisser que le compte rebours termine L armoire de commande reprend son fonctionnement normal sans modifier les param tres r gl s suivi par la r vision du firmware par exemple Pr 1 2 FRANCAIS Temps ouverture En ouverture le moteur viens actionn pour le temps tablit Si armoire d tecte un obstacle ou s interviens le fin cours il peut interrompre l ouverture avant l puisement du temps Temps ouverture partielle acces pi tonne S il recoit un commande de Start Pi tonne l armoire ouvre seulement le portail pour un temps r duit Le maximum du temps qu on peut tablir est t AP Temps de fermeture En fermeture le moteur est actionn pour le temps tablit Si l armoire d tecte un obstacle ou s interviens le fin cours il peut interrompre l ouverture avant l puisement du temps Pour viter que le portail ne se ferme compl tement est conseill d tablir un temps plus long de ceux d ouverture t AP Temps de fermeture partielle acces pi tonne En cas de ouverture partielle l armoire utilise ce temps de fermeture Le
95. liter l entr e pour les photocellules de type 1 c est dire active en ouverture et en fermeture voir le paragraphe installation no Entr e des habilit e la centrale l ignore Il n est pas n cessaire pointer avec le commun Entr e habilit e SIVDNVYS FRANCAIS Entr e photo 2 Ce menu permet de habiliter l entr e pour les photocellules de type 2 c est dire non active en ouverture voir le paragraphe installation no Entr e des habilit e l armoire l ignore Il n est pas n cessaire pointer avec le commun Entr e habilit e aussi portail ferm l ouverture ne commence pas si la photocellule est interrompue Entr e habilit e seulement en fermeture Attention si on choisit cette option il est n cessaire des habiliter le test photocellules Test des dispositifs de s curit Pour garantir une plus grande s curit pour l utilisateur la centrale ex cute avant que ne d bute chaque cycle de fonctionnement normal un test de fonctionnement sur les dispositifs de s curit S il n y a pas d anomalies fonctionnelles le portail entre en mouvement En cas contraire il reste l arr t et le clignotant s allum pour 5 sec L ensemble du cycle de test dure moins d une seconde no fonction non active Foto test habilit que pour les photocellules CoSt test habilit que pour les barres palpeuses Ft Co test habilit soit pour les photocellules soit pour les barres palpeuses A ATT
96. mani re simple les temps de travail et les logiques de fonctionnement Dans le respect des lois europ ennes concernant la s curit lectrique et compatibilit lectromagn tique EN 60335 1 EN 50081 1 et EN 50082 1 elle est caract ris e par le total isolement lectrique du circuit basse tension y compris les moteurs par la tension de r seau Autres caract ristiques e D tection d obstacles par contr le du courant absorb par les moteurs Apprentissage automatique des temps de travail Tests des dispositifs de s curit photocellules barres palpeuses et triac avant de chaque ouverture Desactivation des entr e de securit travers le menu de configuration n est pas necessaire pointer les bornes relatives la securit pas install ca suffit d s habiliter la fonction du menu relatif Possibilit de bloquer la programmation de l armoire travers de la cl optionelle CL1 Fonction du frein Possibilit de piloter des moteurs 400V triphas e 230V triphas e et 230V monophas e Sectionneur de s curit Le mod le CITY6 I est quipp aussi des suivants boutons plac s sur le coffret e Bouton d OUVERTURE Bouton de FERMETURE e Bouton de STOP ALERTE INSTALLATION L installation de l armoire des dispositifs de s curit et des accessoires doit tre faite avec l alimentation d branch e ALIMENTATION ET MOTEURS L armoire de commande doit tre aliment e par une ligne
97. minal resistance 8 2 kohm End of Stroke Inputs City6 control unit allows connecting mechanical ends of stroke normally closed contacts which are activated by the gate motion and showing to the control unit the position of complete opening or closing no End of stroke inputs are disabled Si End of stroke inputs are enabled Anti skid When an opening or closing operation is interrupted by a command or for the intervention of the photocell the set up time for the opposite movement would be excessive so the control unit operates the motors only for the time necessary to recover the actually covered journey This could be not sufficient particularly in the case of very heavy gates as because of the inertia at the inversion moment the gate runs an extra space in the previous direction that the control unit is not able to take into account If after an inversion the gate does not return exactly to the starting position it is possible to set an anti skid time that is added to the time calculated by the control unit in order to recover the inertia A WARNING If function ASM is disabled the gate goes backward until it comes to the end stops In this phase the control unit does not activate the slow down function before the end stops are reached and any obstacle that comes across after the inversion is considered as an end of stroke Activating the obstacle sensor This menu allows you to regulate the sensitivity of the obstacl
98. n appuyant la touche UP au dehors du menu de programmation ou a travers d un metteur m moris sur le canal 1 voir les notices du r cepteur MR2 Il est possible activer la fonction associ e la entr e START P en appuyant la touche DOWN au dehors du menu de programmation ou travers d un metteur m moris sur le canal 2 Les DEL au dessus des contacts P1 et P2 indiquent respectivement l tat des entr es de START et START PI TON Si la DEL est allum e le contact est ferm si est teinte le contact est ouvert BBO 000000 00 SIVDNVYS FRANCAIS RECEPTEUR EMBROCHABLE L armoire City6 est pr par pour le branchement d un r cepteur de la s rie MR2 avec architecture grand sensibilit A ATTENTION Avant de faire ces op rations couper l alimentation la centrale de commande Faire bien attention au vers de branchement des modules extraibles Le module r cepteur MR2 est dou de 4 canaux A chacun on a associ un commande de l armoire City6 e CANAL 1 START e CANAL2 START pi ton e CANAL 3 STOP e CANAL4 R SERV POUR UN USAGE FUTUR A ATTENTION Pour la programmation des 4 canaux et des logiques de fonctionnement lire attentivement les notices jointes au r cepteur MR2 ANTENNE EXTERNE On conseille d utiliser l antenne externe model ANS433 o pour pouvoir garantir la port e maximal Brancher le p le centrale de l antenne au borne A2 de l armoire et le blindage au bo
99. n the power line Check whether the fuse F1 is burnt out if so replace it with same value If replacing the fuse does not solve the problem send the power unit to the V2 to be repaired OVERLOAD led is on It means that there is an overload on accessory power supply 1 Remove the extractable part containing terminals P1 to P14 OVERLOAD led will switch off 2 Remove the overload cause 3 Reinsert the terminal board extractable part and check that this led is not on again Error 1 The following writing appears on display when you exit from programming 0 8 5 9 It means that changed data could not be stored This kind of defect has no remedy and the control unit must be sent to V2 for repair Error 3 When a Start command is given and the gate does not open and the following writing appears on display 8 6 6 8 It means that the photocell test failed Be sure that no obstacle interrupted the photocell beam when the Start command was given Be sure that photocells as enabled by their relevant menus have been installed actually Be sure that photocells are powered and working when you interrupt their beam you should hear the relay tripping Error 4 When a Start command is given and the gate does not open or does a partial opening and the following writing appears on 8 6 6 8 It means that the end of stroke is damaged or that the wiring that connects the sensor to the control unit is broken Change the
100. ne corsa in apertura tra i morsetti P10 e P9 Fine corsa in chiusura tra i morsetti P11 e P9 led sopra i contatti P10 e P11 indicano rispettivamente lo stato dei finecorsa Se il led acceso il contatto chiuso se spento il contatto e aperto 000 0000 HH Pi2 P3 PM P1 L P3 P4 P5 P6 P7 88 P9 P10 P a te C4 24 dg 4 el E ah sk z El B i 3 a a j al STOP Per una maggiore sicurezza possibile installare un interruttore che quando azionato provoca il blocco immediato del cancello L interruttore deve avere un contatto normalmente chiuso che si apre in caso di azionamento Se l interruttore di stop viene azionato mentre il cancello aperto viene sempre disabilitata la funzione di richiusura automatica per richiudere il cancello occorre dare un comando di start se la funzione di start in pausa 6 disabilitata viene temporaneamente riabilitata per consentire lo sblocco del cancello Collegare i cavi dell interruttore di stop tra i morsetti P3 e 84 della centrale ATTENZIONE se l ingresso di STOP non viene utilizzato deve essere ponticellato con il comune comandi COM La funzione dell interruttore di stop pu essere attivata anche mediante un telecomando memorizzato sul canale 3 vedere le istruzioni del ricevitore MR2 Il led sopra il contatto P3 indica lo stato dell ingresso di STOP Se il led acceso il contatto chiuso se spento il contatto aperto 008 00000 OOD INGRESSI DI ATTIVAZIONE
101. ne required switch over the W2 and W3 connections A IMPORTANT the control unit provides no protection to the motors A motor protection device should be installed before the motor ANIRE ENGLISH BLINKER City6 control unit provides for a 230V 40W blinker equipped with intermittence inside Connect blinker cables to terminals B1 and B2 of the control unit Bi B2 230Vac 40W PHOTOCELLS The control unit considers two kinds of photocells depending on the terminal to which they are connected e Photocell 1 that is to say photocells installed on the gate inner side which are active both during the opening and the closing phase When photocells 1 operate the control unit stops the gate as soon as the photocell beam is free the control unit will open the gate completely Photocell 2 that is to say photocells installed on the external gate side and which are active during the closing phase only When photocells 2 operate the control unit opens the gate immediately without waiting for release City6 control unit supplies a 24VAC power supply to photocells and it can perform a photocell operation test before starting the gate opening phase Photocell power terminals are protected by an electronic fuse that stops current in case of overload e Connect power supply cables of photocells transmitter between terminals P13 and P14 of the control unit e Connect power supply cables of photocells receiver between termin
102. ntaci n OVERLOAD de los accesorios FCC Se ala la activaci n del final de carrera en cierre Sefiala la activaci n del final de carrera en apertura Apertura en curso Pausa puerta abierta Cierre en curso IP55 i DACE MAINS ren 1L1 D 3L2 5L3 A EN a LIMIT SWITCHES BE 24 J RECEIVER B OVERLOAD B B BH BB 1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 p13 P14 A ATENCI N Si no se utiliza la entrada STOP debe ser conectada con el com n de comandos COM 230Voc 40W TONVdS4 ESPANOL PANEL DE CONTROL Cuando se activa la alimentaci n el cuadro verifica el correcto funcionamiento del display encendiendo todos los segmentos durante 1 5 seg 8 8 8 8 En los siguientes 1 5 seg se visualiza la versi n del firmware por ejemplo Pr 1 2 Terminado este test se visualiza el panel de control CONTACTO ABIERTO FINAL DE CARRERA CONTACTO CERRADO APERTURA EN CURSO PAUSA PUERTA ABIERTA CIERRE EN CURSO FINAL DE CARRERA DE APERTURA BANDA DE SEGURIDAD 2 BANDA DE SEGURIDAD 1 START PEATONAL UP STOP FOTOCELULA 2 MENU FOTOCELULA 1 El panel de control indica el estado f sico de los contactos en los bornes y de las teclas de programaci n si est encendido el segmento vertical de arriba el contacto est cerrado si est encendid
103. ntrale lo ignora Ingresso abilitato per le coste a gomma conduttiva Ingresso abilitato per le coste semsibili standard con contatto normalmente chiuso Ingresso costa sensibile 2 costa mobile no Ingresso disabilitato la centrale lo ignora rESi Ingresso abilitato per le coste a gomma conduttiva StAn Ingresso abilitato per le coste semsibili standard con contatto normalmente chiuso no Si Ingressi finecorsa 0 5 t AP Antislittamento no Funzione disabilitata no 4 0A Livello del sensore di ostacoli no Si Regolazione dinamica della soglia del sensore di ostacoli 0 0 2 0 Margine sul finecorsa Tempo di inversione Standard 250 ms Rapido 140 ms Visualizzazione dei contatori Numero totale di cicli completati visualizza le migliaia o le unit Numero di cicli prima della prossima richiesta di manutenzione numero arrotondato alle centinaia impostabile a step di 1000 se si imposta O la richiesta disabilitata e viene visualizzato no Apprendimento automatico dei tempi di lavoro Funzione disabilitata Avviamento della procedura di auto apprendimento Fine programmazione Non esce dal menu di programmazione Esce dal menu di programmazione memorizzando i parametri impostati ONVITVLI ITALIANO ANOMALIE DI FUNZIONAMENTO In questo paragrafo ven
104. nutes sont visualis s en ce format Chaque pression du touche UP augmente le temps tablit de 30 seconds chaque pression du touche DOWN diminue de 30 seconds En appuyant et maintenir la touche UP on peut augmenter rapidement le valeur de temps jusqu joindre le maximum pr vu pour cette voix Evidemment on peut diminuer rapidement le temps jusqu joindre le valeur 0 0 en appuyant et en maintenant la touche DOWN En quelque cas le postage du valeur 0 ca veut dire des habiliter la fonction en ce cas au lieu du valeur 0 0 on visualise no En appuyant la touche MENU on valide le valeur visualis et on retourne au menu de configuration Postage des menus de valeur Les menu de valeur sont analogues aux menus de temps mais le valeur tablit est un num ro n importe quel En maintenant appuy la touche UP ou DOWN le valeur augmente ou diminue doucement CONFIGURATION RAPIDE En ce paragraphe on a illustr une proc dure rapide pour configurer l armoire et le mettre imm diatement en ouvre On conseille de suivre du d but ces notices pour v rifier rapidement le correct fonctionnement de l armoire du moteur et des accessoires et apr s modifier la configuration si par hasard quelque param tre ne fuisse pas satisfaisant Pour la position des voix l int rieur du menu et pour les options disponibles pour chaque voix il faut faire r f rence au paragraphe Configuration de l armoire 1 Rappeler une configurati
105. o abilitato per coste sensibili standard con contatto normalmente chiuso Ingresso abilitato per le coste a gomma conduttiva con resistenza nominale 8 2 kohm Ingresso Finecorsa La centrale City6 permette il collegamento di finecorsa meccanici contatto normalmente chiuso che vengono attivati dal movimento delcancello e indicano alla centrale la posizione di completa apertura 0 chiusura no Ingressi disabilitati la centrale li ignora Non necessario ponticellare con il comune Si Ingressi abilitati Antislittamento Quando una manovra di apertura o chiusura viene interrotta con un comando o per intervento della fotocellula il tempo impostato per la manovra opposta sarebbe eccessivo e perci la centrale aziona i motori solo per il tempo necessario a recuperare lo spazio effettivamente percorso Questo potrebbe non essere sufficiente in particolare con cancelli molto pesanti perch a causa dell inerzia al momento dell inversione il cancello percorre ancora un tragitto nella direzione iniziale di cui la centrale non in grado di tenere conto Se dopo un inversione il cancello non ritorna esattamente al punto di partenza e possibile impostare un tempo di antislittamento che viene aggiunto al tempo calcolato dalla centrale per recuperare l inerzia A ATTENZIONE Se la funzione ASM disabilitata la manovra di inversione prosegue fin quando il cancello non va in battuta Ogni ostacolo incontrato dopo l inver
106. o el segmento vertical de abajo el contacto est abierto el dibujo arriba indicado ilustra el caso en el que las entradas START START P FOTO1 FOTO2 COSTA1 COSTA 2 y STOP han sido todos conectadas correctamente En caso de encontrarse instalados protectores sensibles del tipo de goma conductiva el encendido simult neo de ambos segmentos indica que la entrada est cerrada y cerrada sobre la resistencia nominal Los puntos entre las cifras del display indican el estado de los pulsadores de programaci n cuando se pulsa una tecla el punto correspondiente se enciende Las flechas a la izquierda del display indican el estado de los finales de carrera Las flechas se encienden cuando el final de carrera correspondiente indica que la puerta est completamente cerrada o abierta Le frecce a destra del display indicano lo stato del cancello e La freccia pi in alto si accende quando il cancello in fase di apertura Se lampeggia indica che l apertura stata causata dall intervento di un dispositivo di sicurezza costa 0 rilevatore di ostacoli La freccia centrale indica che il cancello in pausa Se lampeggia significa che attivo il conteggio del tempo per la chiusura automatica La freccia pi in basso si accende quando il cancello in fase di chiusura Se lampeggia indica che la chiusura stata causata dall intervento di un dispositivo di sicurezza costa o rilevatore di ostacoli UTILIZACION DE LAS TECLAS DOWN
107. obras debe ser alimentada de una l nea el ctrica protegida con interruptor magnetot rmico diferencial conforme a las normativas de ley La alimentaci n necesaria depende del tipo de motor utilizado y puede ser de tres tipos e trif sico de 400V e trif sico de 230V e monof sico de 230V Los diagramas siguientes indican como se deben conectar la alimentaci n y los cables del motor y como debe programarse el puente de selecci n de la tensi n para cada uno de los casos A ATENCI N antes de aplicar la tensi n aseg rese que el puente de selecci n de la tensi n se ha programado correctamente Una programaci n incorrecta puede da ar severamente la central Trif sico de 400V 230Voc 40W Trifasico de 230V respecto al diagrama anterior s lo se altera el puente de selecci n de la tensi n Monof sico de 230V en este caso es necesario montar un capacitor de protecci n a la sobrecorriente 82 LRH 230Voc 40W Para la conexi n de tierra de los motores con la tierra del dispositivo utilice los bornes W4 y W5 Si la direcci n del movimiento del cancel es contraria a la deseada invierta las conexiones sobre W2 y W3 A ATENCI N el cuadro no suministra ninguna protecci n a los motores Se recomienda instalar un dispositivo de protecci n a sobrecargas antes del motor TONVWdS4 ESPANOL LAMPARA DE SENALIZACION El cuadro City6 prev la utilizaci n de una l mpara de se al
108. oma conductiva las salidas tienen que estar conectadas en cascada y solamente el ltima tiene que ser terminada sobre la resistencia nominal Los diodos luminosos LED sobre los contactos P7 y P8 indican respectivamente el estado de las entradas por protector sensible del tipo 1 y 2 Refi rase a la siguiente tabla para determinar el estado sobre la base del tipo de protector instalado a PRE conductiva LED rojo y verde Contacto abierto Contacto abierto apagados alarma alarma LED rojo encendido Contacto cerrado Protector pulsado LED verde apagado bien alarma LED rojo y verde Resistencia nominal i R encendidos bien FINALES DE CARRERA El cuadro City6 puede funcionar con finales de carrera con interruptor normalmente cerrado que se abre cuando la puerta llega a la posici n deseada Los finales de carrera tienen que estar conectados a los bornes del cuadro de la siguiente forma Final de carrera en apertura entre los bornes P10 y P9 Final de carrera en cierre entre los bornes P11 y P9 00 000000 HH Los diodos luminosos sobre los contactos P10 y P11 indican respectivamente el estado de los finales de carrera Si el diodo se enciende el contacto est cerrado si est apagado el contacto est abierto STOP Para una mayor seguridad es posible instalar un pulsador que cuando viene activado provoca el bloqueo inmediato de la puerta El pulsador tiene que ser de contacto normalmente cerrado que se a
109. on de default voir le paragraphe CHARGEMENT DES PARAMETRES IMPLICITES 2 Etablir les voix StoP Foto CoSt e FC En en fonction des s curit install es sur le portail 3 Demarrer le cycle de auto apprentissage voix APPr Ce derni re op ration serre le menu de configuration et m moire les param tres tablis Procedure d auto apprentissage e Sion a habilit les fin course ou les capteur obstacles le portail est activ en fermeture jusqu aux but e ou la r alisation des fin course de fermeture Si on n a pas habilit les fin corse ou les capteur obstacles le portail doit tre compl tement ferm quand on commence la proc dure Le portail est activ en ouverture jusqu but e ou la r alisation des fin course de ouverture Si les capteurs ne sont pas habilit s ou si ne signalent pas l armoire leur position il faut donner un commande de START quand le portail va joindre la position de ouverture maximum Le portail est activ en fermeture jusqu but e ou la r alisation des fin course de fermeture Si les capteurs ne sont pas habilit s ou si ne signalent pas l armoire leur position il faut donner un commande de START quand le portail va joindre la position de fermeture A ATTENTION la fin du cycle d apprentissage l afficheur visualise pendant quelques instants la valeur d absorption maximum de courant relev pendant le cycle l exception des phases de d marrage L inst
110. on technique ou probl me d installation V2 dispose d un service d assistance clients actif pendant les horaires de bureau TEL 39 01 72 81 24 11 V2 se r serve le droit d apporter d ventuelles modifications au produit sans pr avis elle d cline en outre toute responsabilit pour tous types de dommages aux personnes ou aux choses dus une utilisation imporopre ou une mauvaise installation A Avant de proceder avec l installation et la progarmmation lire attentivement les notices Ce manuel d instruction est destin des techniciens qualifi s dans le domain des automatismes Aucune des informations contenues dans ce livret pourra tre utile pour le particulier Tous operations de maintenance ou programation doivent tre faites travers de techniciens qualifi s L AUTOMATION DOIT TRE R ALIS E CONFORM MENT AUX DISPOSITIFS NORMATIFS EUROP ENS EN VIGUEUR EN 60204 1 S cutit de la machinerie quipement lectriquedes machines partie 1 r gles g n rales S cutit dans liutilisation de fermetures automatis es m thodes d essai S curit dans l utilisation de fermetures automatis es conditions requises EN 12445 EN 12453 L installateur doit pourvoir l installation d un dispositif ex interrupteur magn tothermique qui assure la coupure omnipolaire de l quipement du r seau d alimentation La norme requiert une s paration des contacts d au moins 3 mm pour chaque p le EN 60335
111. ontact normalement ferm Les DEL au dessus des contacts P5 et P6 indiquent respectivement l tat des entr es pour photocellules de type 1 et 2 Si la DEL est allum e le contact est ferm si elle est teinte le contact est ouvert A ATTENTION e Sion installe plusieurs couples de cellules du m me type ses sorties doivent etre branch es en serie e Sion installe des cellules reflex l alimentation doit tre branch e aux bornes P13 et P14 de la centrale pour effectuer le test de fonctionnement 000 0 000 00 PM P1 P3 P4 P5 P6 P7 P8 P9 PIO Pi P2 P3 4 lt 26 lt lt E mila aA at it al 441 3 3 BARRES PALPEUSES Selon le borne ou on les branches l armoire repartit les barres palpeuses en deux cat gories Barre palpeuse type 1 fixe sont install es sur murs ou obstacles fixes ou le portail se rapprochent pendant la phase d ouverture En cas d intervention des barres de type 1 pendant l ouverture du portail l armoire referme le portail pour 3 seconds et puis se bloque en cas d intervention des barres du type 1 pendant la fermeture du portail l armoire va se bloquer immediatement La commande suivant un arr t provoqu par une d tection d obstacle ou par la barre palpeuse provoque le d part du portail dans le sens initial ou dans le sens inverse suivant le param tre programm dans la fonction STOP Barre palpeuse type 2 mouvant sont install es l extr mit du portail En cas d in
112. os motores a la tierra de la red de alimentaci n el cuadro de maniobras City6 est dotada de dos bornes dedicados W4 y W5 No instalar el dispositivo al exterior CONFORMIDAD A LAS NORMATIVAS V2 S p A declara que los productos CITY6 cumplen los requisitos esenciales establecidos por las siguientes directivas 89 336 CEE Directiva EMC seg n las normas EN 55014 1 EN 55014 2 EN 61000 3 2 61000 3 3 2006 95 CEE Directiva de baja tensi n seg n las normas EN 60335 1 y EN 60335 2 103 99 05 CEE Directiva de radio seg n la norma EN 301 489 3 Racconigi a 12 11 2009 El representante legal 2 SPA Cosip 6 De Falc yoo CARACTERISTICAS TECNICAS 400V trif sico 230V trif sico Alimentaci n 230V monof sico Carga m x motor 4A Carga m x accessorios 24V 10W Temperatura de trabajo 20 C 60 C F1 F400mA F2 FIA Fusibles de protecci n F3 12A 500V F4 T250mA Dimensiones 295 x 230 x 100 mm Peso 1900g Grado de protecci n IP55 DESCRIPCION DEL CUADRO El cuadro de maniobras digital City6 es un innovador producto V2 que garantiza seguridad y fiabilidad para la automatizaci n canceles corredizos y portones seccionales industriales El City6 est dotado de un display el cual permite adem s de una f cil programaci n la constante visualizaci n del estado de las entradas adem s la estructura con men s permite una simple programaci n de los tiempos d
113. paragraphe ENTREES DE ACTIVATION AP CH Mode Ouvre Ferme PreS Mode Homme mort oroL Mode Horloge StAn Mode standard no Les entr es Start sur bornes sont des habilit es Les entr es fonctionnent selon le mode StAn Fonction du frein Ce menu permet d activer la fonction du frein gr ce laquelle il est possible d emp cher qu un portail lourd la suite d une commande ou l intervention d une s curit cause de l inertie continue le mouvement pour quelques secondes au lieu de se bloquer imm diatement A ATTENTION Si le moteur est quip de frein lectrom canique automatique cette fonction doit tre obligatoirement d sactiv e Entree stop Ce menu permet de s lectionner le fonctions associ es la commande de STOP Pros La commande de STOP arr te le portail lors de la commande de DEMARRAGE suivante le portail reprend le mouvement dans la direction pr c dente invE commande de STOP arr te le portail lors de la commande de DEMARRAGE suivante le portail reprend le mouvement dans la direction oppos e la pr c dente Le r glage du param tre STOP d termine aussi la direction de mouvement du portail immobile apr s l intervention des barres palpeuses ou du capteur d obstacles suivant le commande de START A ATTENTION pendant la pause la commande de STOP arr te le comptage du temps de pause la commande suivante de DEPART refermera toujours le portail Entr e photo 1 Ce menu permet de habi
114. pido el rayo de las fotoc lulas en el momento que se ha dado el comando de start Asegurarse de que las fotoc lulas que han sido habilitadas a men est n realmente instaladas Asegurarse de que las fotoc lulas est n alimentadas y funcionantes interrumpiendo el rayo se tiene que o r el clic del rel Error 4 Cuando se da un comando de start y la puerta no se abre o se abre solo parcialmente y en el display aparece 8 6 6 8 Significa que il final de carrera est da ado o el cableado que conecta el sensor al cuadro est interrumpido Sustituir el sensor final de carrera o parte del cableado da ado Si sigue apareciendo el error enviar el cuadro de maniobras a V2 para su reparaci n Error 5 Cuando se da un comando de start la puerta no se abre y en el display aparece la sigla 6 2 6 5 Significa que el test de las bandas de seguridad ha fallado si se utilizan bandas a goma conductiva el test viene efectuado aunque no ha sido activado par el menu test Asegurarse de que las bandas de seguridad est n correctamente conectadas Error 9 Cuando se intenta modificar las programaciones del cuadro y en el display aparece la sigla 6 8 8 8 Significa che la programaci n est bloqueada con la llave de bloqueo de programaci n c d CL1 Para proceder a la modificaci n de las programaciones es necesario introducir en el conector interfaz ADI la misma llave utilizada para activar el bloqueo de programaci n
115. r imperativement le cable de terre selon les Normes en vigueur EN 60335 1 EN 60204 1 l armoire de commande City6 est quip e de deux bornes d di es W4 et W5 Ne pas installer le dispositif en dehors CONFORMIT AUX NORMATIFS V2 S p A d clare que les produits CITY6 sont conforment aux qualit s requises essentielles fix es par les directives suivantes 89 336 CEE Directive EMC suivant les normes EN 55014 1 EN 55014 2 EN 61000 3 2 61000 3 3 2006 95 CEE Directive Basse tension suivant les normes EN 60335 1 EN 60335 2 103 99 05 CEE Directive Radio suivant les normes EN 301 489 3 Racconigi le 12 11 2009 Le repr sentant d fhe Cosi De Fal Ye bilit V2 SPA CARACT RISTIQUES TECHNIQUES 400V triphas e 230V Alimentation triphas e 230V monophas e Charge max moteur 4A Charge max accessoires 24V 10W Temp rature de travail 20 C 60 C F1 F400mA F2 FIA F3 T2A 500V F4 T250mA Dimensions 295 x 230 x 100 mm Poids 1900g Protection IP55 DESCRIPTION DE LA CENTRALE L armoire de commande num rique City6 est produit innovant V2 qui assure s curit et fiabilit pour l automatisation de portails coulissants et portes sectionnelles industrielles La City6 est dot e d un affichage qui permet en plus d une programmation ais e le monitoring constant de l tat des entr es de surcroit la structure menus permet de poser de
116. rb par le moteur d passe la valeur introduite l armoire de commande d tecte une alarme Si non est pr r gl la fonction est d sactiv e R glage dynamique du seuil du capteur d obstacles En activant cette fonction l armoire de commande modifie automatiquement le seuil du capteur d obstacles pour compenser l accroissement d effort caus par le vieillissement des m canismes ou par l accumulation de d tritus De toute facon le seuil peut tre augment d une valeur qui peut d passer au maximum de 0 5A la valeur introduite pour le param tre SEnS Marge sur la but e de fin de course Si l installation pr voit que le portail se met en but e contre un arr t m canique en fin de course en ouverture ou en fermeture il faut r gler une marge sur la but e de fin de course temps o le capteur d obstacles ne provoque pas le recul de s curit caus par la but e contre l arr t mais permet de terminer le cycle Si vous introduisez une marge sup rieure aux temps de travail toute intervention du capteur d obstacles provoquera la fin du cycle Si vous introduisez z ro toute intervention du capteur d obstacles provoquera le recul du portail SIVDNVYS FRANCAIS Temp d inversion Le temps d inversion est le temps n cessaire pour inverser le mouvement du moteur quand un dispositif de s curit est activ StAn inversion standard 250ms FASt inversion rapide 140ms Visualisation des compte
117. re Entr e habilit e pour barres palpeuses caoutchouc conducteur Entr e habilit e pour barres palpeuses standard avec contact normalement ferm Entr e barre palpeuse 2 barre palpeuse mobile no Entr e d saffect e la centrale l ignore rESi Entr e habilit e pour barres palpeuses caoutchouc conducteur StAn Entr e habilit e pour barres palpeuses standard avec contact normalement ferm no Si Entr es des but es de fin de course 0 5 t AP Anti patinage no Fonction d sactiv e no 4 0A Niveau du capteur d obstacles no Si R glage dynamique du seuil du capteur d obstacles 0 0 2 0 Marge sur la but e de fin de course Temp d inversion Standard 250 ms Rapide 140 ms Affichage des compteurs Num ro total de cycles compl t s il affiche les milliers ou les unit s Num ro de cycles avant la prochaine demande d entretien num ro arrondi aux centaines r glable par chelon de 1000 si le 0 est pr r gl la demande est d sactiv e et le non est affich Apprentissage automatique des temps de travail Fonction d sactiv e D marrage de la proc dure d auto apprentissage Fin de la programmation Il ne sort pas du menu de programmation Il sort du menu de programmation en m morisant les param tres s lectionn s SIVDNVYS
118. re connect es en s rie Sion utilise plusieurs barres palpeuses caoutchouc conducteur les sorties doivent tre connect es en cascade et seulement la derni re doit tre termin e sur la r sistance nominale Les DEL au dessus des contacts P7 et P8 indiquent respectivement l tat des entr es pour barre palpeuse sensible de type 1 et 2 R f rez vous au tableau indiqu ci dessous pour d terminer l tat sur la base du type de barre palpeuse install e Barre palpeuse Barre palpeuse en traditionnelle caoutchouc conducteur DELs rouge et verte Contact ouvert Contact ouvert alarme teintes alarme DEL rouge allum e Contact ferm Barre palpeuse cras e DEL verte teinte ok alarme DELs rouge et verte R sistance nominale allum es ok FIN COURSE L armoire City6 peut supporter le fin course avec interrupteur normalement ferm que viens ouvert quand le portail arrive la position souhait e Les fin course avec interrupteur doivent tre branch s la borniere de l armoire de facon suivante e Fin course en ouverture entre les bornes P7 et P9 e Fin course en fermeture entre les bornes P8 et P9 Les DEL au dessus des contacts P10 et P11 indiquent respectivement l tat des fin course Si la DEL est allum e le contact est ferm si elle est teinte le contact est ouvert l Bm Od Pour une plus grande s curit il est possible installer un interrupteur que s on l actionne va provoquer le bloqu
119. remidades de la puerta En caso de intervenci n de las bandas del tipo 2 durante la apertura de la puerta el cuadro se bloquea inmediatamente en caso de intervenci n de las bandas del tipo 2 durante el cierre de la puerta el cuadro vuelve a abrir la puerta durante 3 segundos y se bloquea La direcci n de accionamiento de la puerta al siguiente comando de START o START PEATONAL depende del par metro STOP invierte o prosigue el movimiento Ambas entradas son capaces de operar ya sea el protector cl sico con contacto normalmente cerrado o bien el protector de goma conductiva con resistencia nominal de 8 2 KOhm Conectar los cables de las bandas del tipo 1 entre los bornes P7 y P9 del cuadro Conectar los cables de las bandas del tipo 2 entre los bornes P8 y P9 del cuadro Para satisfacer los requisitos de la normativa EN12978 es necesario instalar protectores sensibles de goma conductiva los protectores sensibles con contacto normalmente cerrado deben estar dotados de una centralita que verifica constantemente la funcionalidad correcta Si se utilizan cuadros de maniobras que pueden efect ar el test mediante interrupci n de alimentaci n connectar los cables de alimentaci n del cuardo entre los bornes P13 y P14 En caso contrario connectarlos entre los bornes P12 y P14 A ATENCI N Si se utilizan m s bandas con contacto normalmente cerrado las salidas tienen que estar conectadas en serie Si se utilizan m s bandas a g
120. ri accessori Alimentazione TX fotocellule per Test funzionale Motore vedi paragrafo ALIMENTAZIONE E MOTORI Morsetti per collegare la terra del motore alla terra dell impianto Lampeggiante 230VAC 40W Alimentazione vedi paragrafo ALIMENTAZIONE E MOTORI 400mA 2A 2A 500V Connettore per moduli opzionali MAINS Segnala che la centrale alimentata Segnala un sovraccarico sull alimentazione OVERLOAD degli accessori FCC Segnala l attivazione del finecorsa di chiusura Segnala l attivazione del finecorsa di apertura Apertura in corso Pausa cancello aperto Chiusura in corso IP55 i DACE MAINS ren 1L1 3L2 5L3 Oo P PAN a LIMIT SWITCHES BE 24 J RECEIVER B OVERLOAD B B BH BB 85 86 P7 88 P9 P10 P11 P12 P13 P14 230Voc 40W A ATTENZIONE se l ingresso di STOP non viene uilizzato deve essere ponticellato con il comune comandi COM ONVITVLI ITALIANO PANNELLO DI CONTROLLO Quando viene attivata l alimentazione la centrale verifica il corretto funzionamento del display accendendo tutti i segmenti per 1 5 sec 8 8 8 8 Nei successivi 1 5 sec viene visualizzata la versione del firmware ad esempio Pr 1 2 Al termine di questo test viene visualizzato il pannello di controllo CONTATTO APERTO CO
121. rne A1 INTERFACE ADI L interface ADI Additonal Devices Interface dont la centrale City6 est quip e permet de raccorder des modules optionnels de la ligne V2 Voir le catalogue V2 pour une liste des modules optionnels avec interface ADI disponibles pour cette centrale A ATTENTION Pour l installation des modules optionnels lire attentivement les notices que vous trouvez avec RECEIVER TABLEAU BRANCHEMENTS ELECTRIQUES Blindage antenne Centrale antenne Commande d ouverture pour le branchement de commande traditionnels avec contact N O Commande d ouverture pi ton pour le branchement de commande traditionnels avec contact N O Commande d arr t Contact N F Commun Photocellules type 1 Contact N F Photocellules type 2 Contact N F Barres palpeuse type 1 fixe Contact N F Barres palpeuse type 2 mouvant Contact N F Commun Fin course en ouverture Contact N F Fin course en fermeture Contact N F Sortie alimentation 24 VAC pour photocellules et autres accessories Alimentation TX photocellules pour test de fonctionnement Commun Moteur voir le paragraphe ALIMENTATION ET MOTEURS Bornes pour relier la mise la terre du moteur la terre de l installation Clignotant 230VAC 40W Alimentation voir le paragraphe ALIMENTATION ET MOTEURS 400mA 2A 2A 500V Connecteur pour mod
122. rvention d un dispositif de s ret barre palpeuse ou d tecteur d obstacles EMPLI DES TOUCHES DOWN ET UP POUR LA PROGRAMMATION La programmation des fonctions et des temps de l armoire est faite dans un menu propre de configuration au quel on peut acc der et dans le quel on peut se bouger travers les touches DOWN MENU et UP en bas de l cran Pour activer le mode programmation en m me temps que l cran visualise le panneau de contr le appuyer et maintenir la touche MENU jusqu quand sur l cran va appara tre l crite t AP Le menu de configuration consiste en une liste de voix configurables la sigle que voyez sur l cran indique la voix actuellement s lectionn e En appuyant la touche DOWN on passe la voix apr s en appuyant la touche UP on retourne la voix pr c dente Appuyant la touche MENU on visualise le valeur actuel de la voix s lectionn e et on peut ventuellement le modifier La dernier voix du menu FinE permet de m moriser les modifications effectu es et retourner au fonctionnement normal de la centrale Pour ne pas perdre sa propre configuration est obligatoires sortire du mode de programmation travers de dite voix du menu A ATTENTION si on ne s effectue pas aucune op ration pour plus d un minute l armoire va sortir du mode programmation sans sauver les postages et les modifications effectu e sont perdues En maintenant appuy la touche DOWN les voix du menu de configuration
123. rvento delle fotocellule di tipo 2 la centrale riapre immediatamente il cancello senza attendere il disimpegno La centrale City6 fornisce un alimentazione a 24VAC per le fotocellule e pu eseguire un test del loro funzionamento prima di iniziare l apertura del cancello morsetti di alimentazione per le fotocellule sono protetti da un fusibile elettronico che interrompe la corrente in caso di sovraccarico Collegare i cavi di alimentazione dei trasmettitori delle fotocellule tra i morsetti P13 e P14 della centrale Collegare i cavi di alimentazione dei ricevitori delle fotocellule tra i morsetti P12 e P14 della centrale Collegare l uscita dei ricevitori delle fotocellule di tipo 1 tra i morsetti P4 e P5 della centrale e l uscita dei ricevitori delle fotocellule di tipo 2 tra i morsetti P4 e P6 della centrale Usare le uscite con contatto normalmente chiuso led sopra i contatti P5 e P6 indicano rispettivamente lo stato degli ingressi per fotocellule di tipo 1 e 2 Se il led acceso il contatto chiuso se spento il contatto aperto A ATTENZIONE e Se vengono installate pi coppie di fotocellule dello stesso tipo le loro uscite devono essere collegate in serie e Se vengono installate delle fotocellule a riflessione l alimentazione deve essere collegata ai morsetti P13 e P14 della centrale per effettuare il test di funzionamento 00000 00 P5 P6 P7 88 P9 P10 Pi j 8 B B a a a COSTE SENSIBILI
124. si devono essere collegati a dispositivi con contatto normalmente aperto Collegare i cavi del dispositivo che comanda l ingresso START tra i morsetti P1 e 84 della centrale Collegare i cavi del dispositivo che comanda l ingresso START P tra i morsetti P2 e P4 della centrale La funzione associata all ingresso START pu essere attivata anche premendo il tasto UP al di fuori del menu di programmazione o mediante un telecomando memorizzato sul canale 1 vedere le istruzioni del ricevitore MR2 La funzione associata all ingresso START P pu essere attivata anche premendo il tasto DOWN al di fuori del menu di programmazione o mediante un telecomando memorizzato sul canale 2 led sopra i contatti P1 e P2 indicano rispettivamente lo stato degli ingressi di START e START PEDONALE Se il led acceso il contatto chiuso se spento il contatto aperto BBO 000000 OOD ONVITVLI ITALIANO RICEVITORE AD INNESTO La centrale City6 predisposta per l innesto di un ricevitore della serie MR2 con architettura super eterodina ad elevata sensibilit A ATTENZIONE Prima di eseguire le seguenti operazioni disalimentare la centrale di comando Porre la massima attenzione al verso di innesto dei moduli estraibili Il modulo ricevitore MR2 ha a disposizione 4 canali ad ognuno dei quali associato un comando della centrale City6 e CANALE 1 START e CANALE 2 START PEDONALE e CANALE 3 STOP e CANALE 4 RI
125. sicurezza fotocellule e coste prima di ogni apertura Disattivazione degli ingressi di sicurezza tramite menu di configurazione non occorre ponticellare i morsetti relativi alla sicurezza non installata sufficiente disabilitare la funzione dal relativo menu Possibilit di bloccare la programmazione della centrale tramite la chiave opzionale CL1 Funzione freno Possibilit di pilotare motori 400V trifase 230V trifase e 230V monofase Sezionatore di sicurezza sulla tensione di alimentazione Il modello CITY6 I dotato anche dei seguenti pulsanti installati sul contenitore e Pulsante di APERTURA e Pulsante di CHIUSURA e Pulsante di STOP EMERGENZA INSTALLAZIONE Monofase 230V in questo caso necessario montare un L installazione della centrale dei dispositivi di sicurezza e degli condensatore di spunto accessori deve essere eseguita con l alimentazione scollegata ALIMENTAZIONE E MOTORI La centrale deve essere alimentata da una linea elettrica protetta con interruttore magnetotermico differenziale conforme alle normative di legge L alimentazione necessaria dipende dal tipo di motore utilizzato e pu essere di tre tipi e trifase 400V e trifase 230V e monofase 230V Gli schemi seguenti indicano come devono essere collegati alimentazione e cavi del motore e come deve essere impostato il ponticello di selezione della tensione per ciascun caso A ATTENZIONE prima di dare tensione assicurarsi che
126. sione viene considerato finecorsa Abilitazione del sensore di ostacoli Questo menu permette la regolazione della sensibilit del sensore di ostacoli Quando la corrente assorbita dal motore supera il valore impostato la centrale rileva un allarme Se si imposta no la funzione viene disabilitata Regolazione dinamica della soglia del sensore di ostacoli Abilitando questa funzione la centrale modifica automaticamente la soglia del sensore di ostacoli per compensare l aumento di sforzo causato dall invecchiamento dei meccanismi o dall accumulo di detriti In ogni caso la soglia pu essere aumentata di un valore che pu superare al massimo di 0 5A il valore impostato per il parametro SEnS Margine sul finecorsa Se l installazione prevede che il cancello vada a battuta contro un fermo meccanico a finecorsa in apertura o in chiusura occorre impostare un margine sul finecorsa tempo in cui il sensore di ostacoli non provoca l arretramento di sicurezza causato dalla battuta contro il fermo ma lascia concludere il ciclo Se si imposta un margine superiore ai tempi di lavoro qualsiasi intervento del sensore di ostacoli provochera la fine del ciclo Se si imposta zero qualsiasi intervento del sensore di ostacoli provocher l arretramento del cancello ONVITVLI ITALIANO Tempo di inversione Il tempo di inversione il tempo necessario per invertire il movimento del motore quando interviene una sicurezza S
127. sociada a la entrada START P puede ser activada tambi n pulsando la tecla DOWN mientras est s fuera del men de programaci n o mediante un emisor memorizado en el canal 2 ver las instrucciones del receptor MR2 Los diodos luminosos sobre los contactos P1 y P2 indican respectivamente el estado de las entradas de START y START PEATONAL Si el diodo est encendido el contacto est cerrado si est apagado el contacto est abierto BBO 000000 00 TONVWdS4 ESPANOL RECEPTOR ENCHUFABLE El cuadro City6 est preparado para enchufar un receptor de la serie MR2 con estructura superheterodina con elevada sensibilidad A CUIDADO Antes de efectuar esta operaci n quitar alimentaci n del cuadro de maniobras Tener cuidado con el sentido de conexi n del m dulo receptor extraible El modulo receptor MR2 dispone de 4 canales Cada uno es asociado a un comando de la central City6 CANAL 1 START CANAL 2 START PEATONAL CANAL 3 STOP CANAL 4 RESERVADO PARA USOS FUTUROS A ATENCION Para la programacion des 4 canales y de la logica de funcionamiento leer con atenci n las instrucciones adjuntas al receptor MR2 ANTENA EXTERNA Se aconseja el empleo de un antena externa modelo ANS433 para poder garantizar el maximo alcance Conectar el positivo de la antena al borne A2 del cuadro y la malla al borne A1 INTERFAZ AN El cuadro City6 est dotado de una interfaz ADI Additional Devices Interface que permi
128. st 140 ms Counter viewing Total number of completed cycles views in thousands or in units Number of cycles before the next request for service such a number has been rounded off to hundreds and it can be set up on 1000 step in case it is set up on 0 the request will be disabled and no will be viewed Automatic learning of the operation time Function disabled Start up of the automatic learning procedure End of programming It does not exit from the program menu It exits from the program menu by storing the setup parameters AINE ENGLISH OPERATION DEFECTS This paragraph shows some possible operation defects along with their cause and applicable remedy MAINS led does not switch on It means that there is no voltage on City6 control unit card 1 Make sure there is no voltage interruption at the power unit source and that the switch is turned to ON 2 Before intervening on the control unit disconnect the power supply using the switch fitted on the power unit or other device at source on the power line Check whether the fuse F3 is burnt out if so replace it with same value MAINS led is on but the display does not come on This means that there is no power supply to the transformer s secondary circuit 1 Before intervening on the control unit disconnect the power supply using the switch fitted on the power unit or other device at source o
129. t la pause il recoit un commande de stop l armoire passe automatiquement au fonctionnement semi automatique Fermeture apres le passage Dans le fonctionnement automatique chaque fois qu interviens une photocellule pendant la pause le compte du temps de pause recommence a partir du valeur tablit en ce menu De facon analogue si la cellule interviens pendant l ouverture viens imm diatement charg ce temps comme temps de pause Cette fonction permet d avoir une fermeture rapide apres le passage travers du portail donc on utilise d habitude un temps inferieur Ch AU Si on tablis no on utilise le temps Ch AU Dans le fonctionnement semiautomatique cette fonction n est pas active Pause apres le passage Afin de rendre le plus bref possible le temps pendant lequel le portail reste ouvert il est possible faire arr ter le portail d s que le passage devant les photocellules est d tect Si le fonctionnement automatique est activ le temps de pause est Ch tr Si les photocellules install s sont du type 1 et 2 le portail entre en pause seulement apr s avoir d tect le passage devant les deux photocellules Clignotant en pause Habituellement le clignotant fonctionne seulement pendant le mouvement du portail Se cette fonction est habilit e le clignotant fonctionne aussi pendant le temps de pause Fonction des entr es de Start Ce menu permet de choisir le mode de fonctionnement des entr es voir
130. tAn inversione standard 250ms FASt inversione rapida 140ms Visualizzazione dei contatori Questo menu permette di visualizzare il contatore dei cicli di apertura completati e di impostare gli intervalli di manutenzione Vedere il paragrafo dedicato LETTURA DEL CONTATORE DI CICLI Apprendimento automatico dei tempi di lavoro Questo menu attiva una procedura che consente alla centrale di rilevare autonomamente la durata ottimale dei tempi di lavoro vedere il paragrafo Configurazione veloce Scegliendo l opzione Go il menu di configurazione viene chiuso e inizia il ciclo di apprendimento A ATTENZIONE La procedura di apprendimento automatico dei tempi di lavoro NON pu essere avviata se la centrale impostata in modalit UOMO PRESENTE PrES Fine Programmazione Questo men permette di terminare la programmazione sia predefinita che personalizzata salvando in memoria i dati modificati no ulteriori modifiche da effettuare non uscire dalla programmazione Si modifiche terminate fine programmazione il display visualizza il pannello di controllo I DATI IMPOSTATI SONO STATI SALVATI IN MEMORIA LA CENTRALE ORA PRONTA PER L UTILIZZO LETTURA DEL CONTATORE DI CICLI La centrale City6 tiene il conto dei cicli di apertura del cancello completati e se richiesto segnala la necessita di manutenzione dopo un numero prefissato di manovre Sono disponibili due contatori Totalizzatore non azzerabile dei ci
131. te la conexi n con una serie de m dulos opcionales de la l nea V2 Hacer referencia al cat logo V2 para ver los m dulos opcionales con interfaz ADI disponibles para este cuadro A ATENCION Para la instalaci n de los m dulos opcionales leer atentamente las instrucciones adjunta a cada m dulo RECEIVER TABLA CONEXIONES ELECTRICAS Malla antena Positivo antena START comando de apertura para la conexi n de dispositivos tradicionales de comando N A START P comando de apertura peatonal para la conexi n de dispositivos tradicionales de comando N A Comando de stop Contacto N C Comun Fotoc lulas del tipo 1 Contacto N C Fotoc lula del tipo 2 Contacto N C Bandas del tipo 1 fijas Contacto N C Bandas del tipo 2 en movimiento Contacto N C Comun Final de carrera en apertura Contacto N C Final de carrera en cierre Contacto N C Salida alimentaci n 24 VAC para fotoc lulas y otros accesorios Alimentaci n TX fotoc lulas para Test funcional Motor ver p rrafo ALIMENTACI N Y MOTORES Bornes para conectar la tierra del motor a la tierra del dispositivo L mpara de senalizaci n 230VAC 40W Alimentaci n ver p rrafo ALIMENTACI N Y MOTORES 400mA 2A 2A 500V Conector para modulos opcionales MAINS Senala que el quadro est alimentado Se ala que hay una sobrecarga en la alime
132. temps maximum qu on peut tablir est t CH Pour viter que le portail ne se ferme compl tement est conseill d tablir un temps plus long de ceux d ouverture t APP Temps clignotement pr alable Avant de chaque mouvement du portail le clignotant viens activ pour le temps t PrE pour signaler que commence le mouvement Start en ouverture Ce menu permet d tablir le comportement de l armoire s il recoit un commande de Start pendant la phase d ouverture PAUS Le portail s arr te et entre en pause ChiU Le portail commence imm diatement se fermer no Le portail continue s ouvrir le commande est ignor Pour tablir la logique de fonctionnement pas pas choisir l option PAUS Pour tablir la logique de fonctionnement ouvre toujours choisir l option no Start en fermeture Ce menu permet d tablir le comportement de l armoire s on recoit un commande de Start pendant la phase de fermeture StoP Le portail s arr te et le cycle est consid r termin APEr Le portail se re ouvre Pour tablir la logique de fonctionnement pas pas choisir l option StoP Pour tablir la logique de fonctionnement ouvre toujours choisir l option APEr Start en pause Ce menu permet d tablir le comportement de l armoire s il recoit un commande de Start pendant que le portail est ouvert ou en pause ChiU Le portail commence se refermer no Le commande est ignor Pour tablir la
133. tervention des barres type 2 pendant l ouverture du portail l armoire se bloque imm diatement en cas d intervention des barres type 2 pendant la fermeture du portail l armoire re ouvre le portail pour 3 seconds et apr s se bloque La commande suivant un arr t provoqu par une d tection d obstacle ou par la barre palpeuse provoque le d part du portail dans le sens initial ou dans le sens inverse suivant le param tre programm dans la fonction STOP Les deux entr es sont en mesure de g rer soit la barre palpeuse classique avec contact normalement ferm soit la barre palpeuse en caoutchouc conducteur avec r sistance nominale 8 2 kohm Brancher les c bles des barres de type 1 entre les bornes P7 et P9 Brancher les c bles des barres de type 2 entre les bornes P8 et P9 Pour satisfaire les exigences de la r glementation EN12978 il est n cessaire d installer des barres palpeuses sensibles en caoutchouc conducteur les barres palpeuses sensibles avec contact normalement ferm doivent tre quip es d une centrale de commande qui en v rifie constamment le fonctionnement correct Si on utilise centrales qui peuvent ex cuter le test par coupure du courant lectrique connecter les c bles d alimentation de la centrale entre les bornes P13 et P14 de la City6 Dans le cas contraire connecter les entre les bornes P12 et P14 A ATTENTION Sion utilise plusieurs barres palpeuses avec contact norm ferm les sorties doivent t
134. tion manual is only for qualified technicians who specialize in installations and automations The contents of this instruction manual do not concern the end user Every programming and or every maintenance service should be done only by qualified technicians AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE WITH THE EUROPEAN REGULATIONS IN FORCE EN 60204 1 Machinery safety electrical equipment of machines part 1 general rules Safe use of automated locking devices test methods Safe use of automated locking devices requirements EN 12445 EN 12453 The installer must provide for a device es magnetotermical switch ensuring the omnipolar sectioning of the equipment from the power supply The standards require a separation of the contacts of at least 3 mm in each pole EN 60335 1 After making connections on the terminal board use one hose clamp to fix dangerous voltage wires near the terminal board and another hose clamp to fix safety low voltage wires used for accessories connection this way in case of accidental detachment of a conducting wire dangerous voltage parts will not come into contact with safety low voltage ones The plastic case has an IP55 insulation to connect flexible or rigid pipes use pipefittings having the same insulation level Installation requires mechanical and electrical skills therefore it shall be carried out by qualified personnel only who can issue the Compliance Certificate con
135. tipo impulsivo un impulso provoca la apertura o el cierre total de la puerta Modalidad Hombre Presente START APERTURA manda siempre la apertura START P CIERRE manda siempre el cierre El comando es de tipo monoestable la puerta se abre o se cierra mientras que el contacto est cerrado y se para inmediatamente si el contacto se abre Modalidad Reloj Esta funci n permite programar durante el d a las franjas horarias de apertura de la puerta utilizando un reloj programador exterior START START un comando provoca la apertura total de la puerta START P 2 START PEATONAL un comando provoca la apertura parcial de la puerta La puerta queda abierta mientras que el contacto permanece cerrado en la entrada cuando el contacto se abre empieza el tiempo de pausa terminado este tiempo la puerta vuelve a cerrar Es indispensable habilitar el cierre autom tico En cualquier modalidad las entradas tienen que estar conectadas a dispositivos con contacto normalmente abierto Conectar los cables del dispositivo che comanda la entrada START entre los bornes P1 y P4 del cuadro Conectar los cables del dispositivo che comanda la entrada START P entre los bornes P2 y P4 del cuadro La funci n asociada a la entrada START puede ser activada tambi n pulsando la tecla UP mientras est s fuera del men de programaci n o mediante un emisor memorizado en el canal 1 ver las instrucciones del receptor MR2 La funci n a
136. uadro y la salida de los receptores de las fotoc lulas del tipo 2 entre los bornes P4 y P6 del cuadro Utilizar las salidas con contacto normalmente cerrado Los diodos luminosos sobre los contactos P5 y P6 indican respectivamente el estado de las entradas por fotoc lula del tipo 1 y 2 Si el diodo se enciende el contacto est cerrado si est apagado el contacto est abierto A ATENCION Si se instalan m s parejas de fotoc lulas del mismo tipo sus salidas tienen que estar conectadas en serie Si se instalan fotoc lulas de espejo la alimentaci n tiene que estar conectada entre los bornes P13 y P14 del cuadro para poder efectuar el test de funcionamiento 000 00 BANDAS DE SEGURIDAD Seg n el borne donde est n conectadas el cuadro divide las bandas de seguridad en dos categor as Bandas del tipo 1 fijas est n instaladas en la pared o en otros obst culos fijos donde la puerta se pueden acercar durante la apertura En caso de intervenci n de las bandas del tipo 1 durante la apertura de la puerta el cuadro vuelve a cerrar la puerta durante 3 segundos y se bloquea en caso de intervenci n de las bandas del tipo 1 durante el cierre de la puerta el cuadro se bloquea inmediatamente La direcci n de accionamiento de la puerta al siguiente comando de START o START PEATONAL depende del par metro STOP invierte o prosigue el movimiento Bandas del tipo 2 en movimiento est n instaladas en las ext
137. uale di istruzioni destinato solamente a personale tecnico qualificato nel campo delle installazioni di automazioni Nessuna delle informazioni contenute all interno del manuale pu essere interessante o utile per l utilizzatore finale Qualsiasi operazione di manutenzione o di programmazione deve essere eseguita esclusiavamente da personale qualificato L AUTOMAZIONE DEVE ESSERE REALIZZATA IN CONFORMIT VIGENTI NORMATIVE EUROPEE EN 60204 1 Sicurezza del macchinario equipaggiamento elettrico delle macchine parte 1 regole generali Sicurezza nell uso di chiusure automatizzate metodi di prova Sicurezza nell uso di chiusure automatizzate requisiti EN 12445 EN 12453 L installatore deve provvedere all installazione di un dispositivo es interruttore magnetotermico che assicuri il sezionamento onnipolare del sistema dalla rete di alimentazione La normativa richiede una separazione dei contatti di almeno 3 mm in ciascun polo EN 60335 1 Una volta effettuati i collegamenti sulla morsettiera necessario mettere delle fascette rispettivamente sui conduttori a tensione di rete in prossimit della morsettiera e sui conduttori per i collegamenti delle parti esterne accessori In tal modo nel caso di un distacco accidentale di un conduttore si evita che le parti a tensione di rete possano andare in contatto con parti a bassissima tensione di sicurezza Per la connessione di tubi rigidi e flessibili o passacavi utiliz
138. uellement le nombre de cycle apr s le quel sera nouveau demand e l entretien Si ne viens pas tablit un nouveau valeur on laisse le compteur z ro la fonction de signalisation de la requ te de entretien est des habilit e et la signalisation ne viens plus r p t A ATTENTION les op ration d entretien doivent tre faites seulement par personnel qualifi SIVDNVYS FRANCAIS DISPLAY DONNES TABLEAU FONCTIONS City6 DESCRIPTION DEFAULT MEMO DONNES 0 0 5 0 Dur e ouverture portail 15 0 0 0 t AP1 Dur e ouverture portail pi ton 6 0 0 0 5 0 Dur e fermeture portail 16 0 0 0 t Ch Dur e fermeture portail pi ton 7 0 0 5 1 0 Pre flashing time 1 0 no Pr signal d sactiv il correspond a la valeur de 0 D marrage en ouverture Le command START n est pas capt e Le portail se referme Le portail se met en pause D marrage en fermeture Le portail conclut le cycle Le portail s ouvre nouveau D marrage en pause La commande de d marrage n est pas capt e Le portail se referme D marrage pi ton en ouverture La commande de START P n est pas re ue Le portail se referme Le portail entre en pause Fermeture automatique no D sactiv elle correspond la valeur de 0 0 5 20 0
139. ul display appare la scritta 0 8 5 9 Significa che non e stato possibile salvare i dati modificati Questo malfunzionamento non rimediabile dall installatore La centrale deve essere inviata alla V2 per la riparazione Errore 3 Quando viene dato un comando di start il cancello non si apre e sul display appare la scritta 8 6 6 8 Significa che fallito il test delle fotocellule 1 Assicurarsi che nessun ostacolo abbia interrotto il fascio delle fotocellule nel momento in cui stato dato il comando di start Assicurarsi che le fotocellule che sono state abilitate da menu siano effettivamente installate Se vengono usate fotocellule di tipo 2 assicurarsi che la voce di menu Fot2 sia impostata su CF CH Assicurarsi che le fotocellule siano alimentate e funzionanti interrompendo il fascio si deve sentire lo scatto del rel Errore 4 Dopo pochi centimetri di apertura il cancello si ferma e sul display compare la scritta 8 6 6 8 Significa che il finecorsa in chiusura non stato rilasciato Assicurarsi che i finecorsa siano collegati correttamente e che il cancello aprendosi pemetta al finecorsa di aprirsi Errore 5 Quando viene dato un comando di start il cancello non si apre e sul display appare la scritta 6 6 0 0 Significa che fallito il test delle coste sensibili Assicurarsi che la centralina di controllo delle coste sia collegata correttamente e funzionante Assicurarsi che le coste che sono state
140. ules optionnels MAINS Signale que la centrale est aliment e Signale surcharge sur l alimentation des OVERLOAD accessories FCC Signal l activation des fin course de fermeture Signal l activation des fin course de ouverture Ouverture en course Pause portail ouvert Fermeture en course IP55 i DACE MAINS ren 1L1 3L2 5L3 o D PAN a LIMIT SWITCHES BE 24 J RECEIVER B OVERLOAD B B BH BB 85 86 P7 P8 P9 P10 P11 P12 P13 P14 230Voc 40W A ATTENTION L entr e STOP si non utilis e doivent tre shunt e avec le commun commandes COM SIVDNVYS FRANCAIS PANNEAU DE CONTROLE Quand on active l alimentation l armoire v rifie le correct fonctionnement de l cran en allumant tous les segments pour 1 5 sec 8 8 8 8 Dans les 1 5 sec suivants vient visualis e la version du logiciel pour exemple Pr 1 2 A la fine de ce test vient visualis le panneau de contr le CONTACT OUVERT CONTACT FERM OUVERTURE EN COURS PAUSE PORTAIL OUVERT FERMETURE EN COURS FIN COURSE EN FERMETURE FIN COURSE EN OUVERTURE START BARRE PALPEUSE 2 DOWN BARRE PALPEUSE 1 START PI TON UP STOP PHOTOCELLULE 2 MENU PHOTOCELLULE 1 Le panneau de contr le signale l tat physique des contacts la plaque bornes et des touches de programm
141. urs Ce menu permet de visualiser le compteur des cycles d ouverture compl t s et d tablir les intervalles d entretien Voir le paragraphe Lecture du compteurs de cycles plus avants Apprentissage automatique des temps de travail Ce menu active une proc dure permettant la centrale de relever la dur e optimale des temps de travail de mani re autonome voir le paragraphe Configuration rapide Choisissant l option Go le menu de configuration viens ferm et commence le cycle de apprentissage A ATTENTION La proc dure d apprentissage automatique des temps de travail NE peut pa tre d marr e si les entr es de Start sont pr r gl es en mode d op ration HOMME MORT PrES Fin de programmation Ce menu permet de terminer la programmation aussi bien pr d finie que personnalis e en m morisant les donn es modifi es no Modifications ult rieures effectuer ne pas sortir de la programmation Si Modifications termin es fin de programmation LES DONNEES PREREGLEES ONT ETE MEMORISEES LA CENTRALE EST DESORMAIS PRETE POUR L UTILISATION LECTURE DU COMPTEURS DE CYCLES L armoire City6 tiens le compte des cycles d ouverture du portails compl t s et si souhait signale la n cessite d entretien apr s un nombre fix de man uvres Il y a a disposition deux compteurs Totalisateur des cycles d ouverture compl t s qu on peut pas le mettre a z ro option tot de la voix Cont Compteur d
142. vamente por personal calificado TONVWdS4 ESPANOL DISPLAY DATOS TABLA DE FUNCION City6 DESCRIPCION DEFAULT 0 0 5 0 iempo apertura puerta 15 0 0 0 t AP1 iempo apertura peatonal 6 0 0 0 5 0 16 0 0 0 t Ch iempo cierre peatonal 7 0 0 5 1 0 T T Tiempo cierre puerta T T iempo predestello 1 0 no Predestello deshabilitado corresponde al valor 0 Start en apertura El comando START no la admite La puerta se cierra La puerta entra en pausa Start en cierre La puerta concluye el ciclo La puerta se abre Start en pausa El comando de START no lo admite La puerta se cierra Start peatonal en apertura El comando de START P no lo admite La puerta se cierra La puerta entra en pausa Cierre autom tico no La puerta cierra despu s del tiempo programado 0 5 20 0 El cierre autom tico no est activado corresponde al valor 0 Cierre despu s del transito no Cierre despu s del transito deshabilitada 0 5 20 0 La puerta se cierra despu s del tiempo programado no Si Pausa despu s del tr nsito no Si L mpara de sefializaci n en pausa Funcionamiento de las entradas de Start Modalidad Abre Cierra Modalidad Hombre Presente Modalidad Reloj
143. vice required see paragraph READING OF CYCLE COUNTER Automatic Learning of the Operation Time This menu will activate a procedure enabling the control unit to automatically find the best duration of the operation time See paragraph Quick Configuration When you select Go configuration menu closes and the learning cycle starts A WARNING The procedure of the operation time automatic learning can NOT be starter if the Start inputs are set up on the MANNED OPERATION mode PrES End of Programming This menu allows to finish the programming both default and personalized saving the modified data into memory no Further corrections to carry out do not quit the programming Si End of programming THE INSERTED DATA HAVE BEEN MEMORIZED THE CONTROL UNIT IS READY TO BE USED READING OF CYCLE COUNTER City6 control unit counts the completed opening cycles of the gate and if requested it shows that service is required after a fixed number of cycles There are two counters available e A totalizing counter for completed opening cycles that cannot be zeroed option tot of item Cont e A downward counter for the number of cycles before the next request for service option SErv of item Cont This counter can be programmed according to the desired value The side scheme shows how to read the totalizing counter how to read the number of cycles before the next service is required as well as how to program the numb
144. zare raccordi conformi al grado di protezione IP55 o superiore L installazione richiede competenze in campo elettrico e meccanico deve essere eseguita solamente da personale qualificato in grado di rilasciare la dichiarazione di conformit di tipo A sull installazione completa Direttiva macchine 89 392 CEE allegato IIA E obbligo attenersi alle seguenti norme per chiusure veicolari automatizzate EN 12453 EN 12445 EN 12978 ed alle eventuali prescrizioni nazionali Anche l impianto elettrico a monte dell automazione deve rispondere alle vigenti normative ed essere eseguito a regola d arte La regolazione della forza di spinta del cancello deve essere misurata con apposito strumento e regolata in accordo ai valori massimi ammessi dalla normativa EN 12453 Consigliamo di utilizzare un pulsante di emergenza da installare nei pressi dell automazione collegato all ingresso STOP della scheda di comando in modo che sia possibile l arresto immediato del cancello in caso di pericolo Collegare il conduttore di terra dei motori all impianto di messa a terra della rete di alimentazione la centrale City6 6 dotata di due morsetti dedicati W4 e W5 Non installare il dispositivo in ambienti esterni CONFORMIT ALLE NORMATIVE V2 S p A dichiara che i prodotti CITY6 sono conformi ai requisiti essenziali fissati dalle seguenti direttive 89 336 CEE Direttiva EMC secondo le norme EN 55014 1 EN 55014 2 EN 61000 3 2 61000 3 3 2006 95 CEE

Download Pdf Manuals

image

Related Search

ATENCION atencion ivan cornejo lyrics atencion al cliente atencion medica atencion en ingles atencion plena atencion a clientes telcel atencion primaria en salud atencion a clientes volaris atencion a clientes atencion al cliente tigo atencion lyrics atencion a clientes telmex atencion atencion recopilacion atencion a clientes dhl atencion a clientes bbva atencion al cliente fedex atencion in english atencion a clientes movistar atencion al cliente apple atencion ivan cornejo lyrics english atencion al cliente whatsapp atencion al cliente samsung atencion al cliente amazon atencion al cliente claro atencion al cliente movistar

Related Contents

Samsung NX11 (20 mm) دليل المستخدم  Oregon Scientific BAR609HGA User's Manual  Première déclaration, le mode d`emploi 29/04/2014  Panasonic MC-V5271 Vacuum Cleaner User Manual  Toshiba Total Storage Platform  取扱説明書PDF(0.6MB)  Screen(392KB)  CM4 Four-Point Continuous Monitor Technical Handbook  イワキ定量ポンプ  COCKERHAM PARISH HALL OPERATING INSTRUCTIONS  