Home

BABY BA e BABY AM

image

Contents

1. C mRM T LINCE LINCE ITALIA S p A SINGERT REG N 4796 UNI EN ISO 9001 2008 Rilevatori a tenda Curtain detectors BABY BA e BABY AM Art Item 1777BABY BA 1779BABY AM 1787BABY BA M 1789BABY AM M MANUALE DI INSTALLAZIONE TECHNICAL MANUAL _ C MADE IN ITALY LINCE J Indice Contents REEL S LO 3 Local S dCLAboutyoutdeVIGG suec reed 3 EZAN a 3 1 2 and maintenance 3 1 3 Contenuto della confezione 4 1 3 Package contents 4 1 4 Identificazione delle parti 4 1 4 Parts identification 4 1 5 Principi di funzionamento 5 5 1 6 Determinazione area di copertura 6 1 6 Determining the detection area 6 Zalone 24h 8 2 1 Montaggio del rilevatore 8 2 1 Detector mounting 8 2 2 Cablaggio del rilevatore D 22 Detector WDO Iram 9 2 3 Configurazione del rilevatore O 22 9 DetectoP SU 9 SPERO HS TIME 12 S SDeCIHOOLIOTIS 12 Le informazioni riportate in questo manuale sono state compilate con cura tuttavia LINCE ITALIA S p A pu essere ritenuta responsabile per eventuali errori e o omissioni LINCE ITALIA S p A si riserva il diritto di apportare
2. 25 75 umidit relativa di 4 75 average relative humidity is 4 meters metri Particolari condizioni ambientali Depending on the environment conditions the possono aumentare o diminuire tale portata coverage could be higher or lower Please use the Utilizzare il MW Trimmer per regolare la MW Trimmer to adjust the microwave sensibility portata della microonda LED giallo ed yellow LED reaching the optimal coverage ottenere una copertura ottimale LINCE 6 12 e Larghezza della finestra porta e Window door width La copertura massima del rilevatore in larghezza rif The maximum detector coverage width ref pag 6 figure installazione A nella figura di pag 6 dipende installation A depends of installation height In the following dell altezza di installazione table some values are shown e Area di copertura e Detection area VISTA FRONTALE FRONT VIEW VISTA FRONTALE FRONT VIEW 5 5 x VISTA DALL ALTO TOP VIEW VISTA DALL ALTO TOP VIEW LINCEI 7 12 2 Installazione 2 Installation Per una corretta installazione seguire le istruzioni di Please use this chapter procedure to install correctly the questo capitolo detector 2 1 Montaggio del rilevatore 2 1 Detector mounting Fori di fissaggio Fixing holes Base del rilevatore Detector bottom Tasselli di fissaggio Maia du ea Wall fixing screws Guarnizione gi installata Gasket already inside Coperchio co
3. metal walls etc e Avoid to fix the detector in front of fluorescent lamps or in proximity of them Connections shielded cable is suggested and one cable per detector is preferred e Separate as far as feasible the alarm system cables from the mains cables 3 12 1 3 Contenuto della confezione 1 3 Package contents Tappo copri LED LED cap cover m c E Manuale di istruzioni dM ii ad Technical manual cc 69 5 9 9 9 9 8 OO UL De up P He e 9 eo _ ff dd pe KIT tasselli e viti Plugs and screws KIT 1 4 Identificazione delle parti 1 4 Parts identification DIP switches B DIP switches A MW Trimmer LEDs Microonda PERS Verdel Greenl PIRI Microwave Verde2 Green2 PIR2 Giallo Yellow Microonda Microwave Rosso Red Allarme Alarm O LINCEI 4 12 1 5 Principi di funzionamento 1 5 Unit features Installazione Tipica Typical installation Installazione finestra Tasta azione porta Window installation Door installation Funzione avanzate Enhanced features Tentativo di manomissione Tampering attempt Lente coperta da un oggetto Lens covered by object se Il circuito anti mascheramento ad IR attivi genera un Qualsiasi tentativo di manomissione apertura coperchio e segnale di allarme sabotaggio q
4. POWER using a power alimentazione compresa tra 9 e 15 supply voltage between 9 Vdc and 15 Vdc e Collegare 1 restanti morsetti di uscita alle e Wire the remaining normally closed terminal blocks linee della vostra centrale di allarme secondo with your control panel according to references 1 riferimenti e 12 AM Vedi Nota e 2 AM See Note e ALARM Allarme e ALARM Alarm e TAMPER Sabotaggio e TAMPER Antitamper Morsetti di alimentazione Power terminals Nota nella versione BA il DICITO da gt morsetto 1 collegato al BABY BA lid Ed nd OFF delle centrali LINCE Sk inibisce il funzionamento della microonda ad impianto disinserito Morsetti di uscita allarmi NC il morsetto 2 non viene usato Alarms terminal blocks AM POWER ALARM TAMPER Note for BA version the 1 terminal connected to the LINCE S control panel terminal OFF switchs off the microwave when the alarm system 1s armed The AM terminal blocks for the AM version exist as antimasking line 2 3 Configurazione del rilevatore 2 3 Detector set up Per una corretta configurazione seguire le istruzioni di Please use this paragraph procedure to set up correctly the questo paragrafo detector 2 3 1 Descrizione dei DIP switch 2 3 1 DIP switches configuration Nota 1 morsetti AM sono usati sulla versione AM come antimascheramento CERERE 3 5D 5
5. block normally closed marked TAMPER see figure in par 2 2 In a hostile 10 12 TAMPER vedi figura par 2 2 In ambiente ostile la sensibilit della funzione antimanomissione pu essere settata tramite 11 DIP switch A4 In una installazione tipica questo morsetto deve essere collegato ad una linea attiva 24h 2 3 4 Installazione di pi sensori in uno stesso ambiente Se fosse necessario installare pi di un rilevatore nello stesso ambiente impostare un canale differente per ogni apparecchio utilizzando 1 seguenti DIP switch e Vedi tabella Par 2 3 1 e 2 Vedi tabella Par 2 3 1 Nota Anche nel caso di un solo rilevatore nello stesso ambiente se ci fossero problemi di interferenza con altri apparati possibile utilizzare 1 DIP switch riportati sopra modificare 1 canali di funzionamento della microonda 2 3 5 Installazione interna esterna Nell installazione in ambienti interni dovrebbero essere evitate posizioni vicino distanza minore di 1 metro a trasmettitori ricevitori di radiofrequenza reti wi fi ripetitori televisivi o altri apparati Nell installazione in ambienti esterni deve essere evitata l installazione in posizioni in cui le lenti del rilevatore vengano investite dalla luce solare diretta rif installazione B pag 6 In ambiente esterni raccomandata la seguente Impostazione dei DIP switch e B2 OFF B4 OFF B6 OFF Effettuare una prova di portata per regolare la sensibilit microonda
6. utilizzando il MW Trimmer girare in senso orario per max sensibilit 2 3 6 Funzione CWS Il rilevatore produce una copertura a tenda par 1 6 E stata implementata una funzione che rende meno sensibile la rilevazione in una delle direzioni di camminamento trasversale rif E figura pag 6 denominato CWS Cross Walking Sensibility tale configurazione viene attivata dai seguenti DIP switch vedi par 2 3 1 per descrizione DIP switch e B2 ON B3 OFF Attraversamento secondo 1l vedi figura in basso e B2 ON B3 ON Attraversamento contrario al verso della freccia disegnata sul circuito causa un allarme vedi figura in basso LINCE verso della freccia disegnata sul circuito causa un allarme _ environment the antitamper could be set using the DIP switch A4 For a standard installation please connect this terminal block to a 24 hrs active line 2 3 4 Installing more detectors the same environment If more than one detector is mounted in the same environment a different microwave channel setting is needed for each device Please use these DIP switches e see Par 2 3 1 table e 2 see Par 23 1 table Note Even if only one device is mounted in the same environment if some radio frequency interferences with other devices are highlighted please use the above DIP switches to set a different microwave channel 2 3 5 Installation In the internal
7. 256x34x41 mm Dimensions 256x34x41 mm Peso 150g Weight 150g Contenitore Policarbonato resistente UV Casing UV resistant polycarbonate LINCE ITALIA S p A Via Variante di Cancelleria snc 00040 Ariccia Roma tel 39 06 9301801 fax 39 06 930180232 info g lince net LINCE 001530 00539AF 12 12
8. PABEBE 123456 DIP switches DIP switches B LINCE 9 12 DIP switches Selezione EE M Selezione frequenza manuale automatica default A2 Frequenza 1 Frequenza 2 se AI ON default Antimascheramento Antimascheramento bassa sensibilit alta sensibilit default Tamper bassa Tamper sensibilit sensibilit normale default DIP switches B LED spenti dopo 4 em minuti default CWS ON CWS OFF default B3 CWS direzione CWS direzione se B2 ON opposta freccia freccia scheda scheda par 2 3 6 default par 2 3 6 B4 Sensibilit PIR alta Sensibilit PIR bassa default B5 Allarme doppio Allarme singolo impulso impulso default PIR in OR PIR in AND default 2 3 2 LED I LED segnalano l attivazione del singolo sensore come di seguito riportato vedi anche la figura par 1 4 e rosso si accende ad ogni rilevazione di allarme e LED giallo si accende ogniqualvolta la microonda rileva una presenza e LED verde si accende ogniqualvolta uno dei due sensori IR rileva una presenza Quando il rilevatore rileva un tentativo di mascheramento 1 quattro LED lampeggiano lentamente Quando il rivelatore rileva un tentativo di rimozione sabotaggio del sensore 1i quattro LED lampeggiano velocemente accelerometro I LED del rilevatore possono essere attivati utilizzando il DIP switch B1 2 3 3 accelerometro Il ri
9. e da quelli della rete elettrica LINCE 1 1 About your device The BABY detectors developed for windows and main doors protection are the state of the art in the microprocessor controlled triple technology intrusion detectors Their slim body allows the installation between external windows and internal closure They are provided of two PIRs and a microwave integrated on the printed circuit board The microwave can be selected on different channels BABY AM in order to avoid interferences between different detectors installed in the same environment Innovative antitamper function based on a 3 axis accelerometer MEMS technology used as tampering and positioning sensor Excellent continuous antimasking technology achieved by active infrared beams scan Other features e Casing in polycarbonate and Fresnel lenses UV resistant e Carefully developed aesthetic and mechanical design e Electronic board built in in a compartment matching with the base provided of a sealing gasket IP55 e EN 50131 1 grade 3 compliant e Cross Walking Sensibility sets the cross walking PIR detection e Electrical connections by means of a removable terminal block for easy installation 1 2 Care and maintenance e Install the detector on rigid surfaces free of vibrations e Avoid to fix the detectors near to heat sources or at direct sunlight e Avoid electromagnetic energy reflection on wide surfaces such as mirrors
10. ee par 2 3 table 2 3 8 Double impulse alarm In difficult environmental conditions and for closed gates which require long time burglary the double impulse alarm could be activated using DIP switch B5 When this function is activated the alarm relay will be activated only with two alarm detections within 15 seconds 2 3 9 Antimasking AM only version To protect the PIR sensor the detector is equipped with an antimasking active IR system this feature is adjustable using the DIP switch A3 see par 2 3 1 table that drives a tamper alarm within around 3 minutes The antimasking affect on the terminal block normally closed marked AM see figure par2 2 For a standard installation please connect this terminal block to 24 hrs active line 3 Specifications Power supply 9 15 Vdc Current consumption 12 Vdc 35 mA max Microwave frequency S Band Alarm masking tamper contacts MOS FET relay 400 mA 60 V 2 Q max Motion detection coverage See par 1 6 Antitamper function 3 axis accelerometer Alarm time ls Antimasking BABY AM only Active IRs 4 signal LEDs 2 greens 1 yellow and 1 red Enclosure degree of protection IP55 Environmental classification Class EN 50131 1 Grado di sicurezza Grado 3 EN 50131 1 Security grading Grade 3 EN 50131 1 Temperatura di funzionamento 25 150 C Operating temperature 25 C 50 C Dimensioni
11. ente la microonda selezionabile su pi canali antimanomissione Funzione con differenti BABY AM innovativa realizzata accelerometro su 3 assi a tecnologia MEMS che garantisce la protezione contro l apertura del rilevatore l antiasportazione dal muro e pi in generale qualsiasi tentativo di effrazione Protezione antimascheramento tramite scansione a raggi infrarossi attivi Altre caratteristiche Contenitore in policarbonato e lenti di Fresnel resistenti ai raggi UV Design estetico e meccanico particolarmente curato Scheda elettronica alloggiata in un compartimento ad elevato grado IP IP55 Conforme alle norme EN 50131 1 grado 3 Funzione CWS Cross Walking Sensibility permette di gestire la sensibilit dei PIR nell attraversamento trasversale Installazione elettrica facilitata per mezzo di morsettiera estraibile 1 2 Avvertenze Installare il sensore su superfici rigide prive di vibrazioni Evitare il posizionamento del sensore vicino a fonti di calore o alla luce diretta del sole Evitare la riflessione dell energia elettromagnetica su ampie superfici quali ad esempio specchi pareti metalliche etc Evitare di puntare il sensore su lampade fluorescenti o comunque di porlo nelle immediate vicinanze delle stesse Per i collegamenti consigliabile utilizzare un cavo schermato e preferibilmente un cavo per ogni sensore Separare per quanto possibile 1 cavi dell impianto di allarm
12. environment should be avoided sites near less than 1 meter radio frequency transmitter receiver e g wifi router TV transmitter In the external environment should be avoided sites in which the detector lenses are directly exposed to the sunlight ref installation B pag 6 In outdoor environment the following DIP switches configuration is recommended e B2 OFF e 4 OFF e OFF Please use the MW Trimmer to adjust the microwave sensibility yellow LED reaching the optimal coverage to maximize coverage turn the trimmer clockwise 2 3 6 CWS feature The detector coverage is a curtain proprietary detection CWS Feature has been developed to desensitise the cross walking detection direction ref E figure in the pag 6 To activate this detection mode please set the DIP switch in the following mode e B2 ON B3 OFF Crossing walk following the downwards arrow it s a cause of alarm fig below e B2 0ON ON Crossing walk following the backwards arrow it s a cause of alarm fig below Es ed en e Ee e D 11 12 2 3 7 Sensibilit PIR Se fosse necessario installare un rilevatore in un ambiente ostile es all aperto con possibile presenza di riflessi solari etc abbassare la sensibilit dei PIR agendo sul DIP switch B4 vedi tabella par 2 3 1 2 3 8 Allarme doppio impulso In ambienti particolarmente ostili e su varchi chiusi che richiedono tempi di effrazio
13. in ogni momento e senza preavviso miglioramenti e o modifiche ai prodotti descritti nel presente manuale Consultare il sito www lince net per le condizioni di assistenza e garanzia LINCE ITALIA p A pone particolare attenzione al rispetto dell ambiente Tutti 1 prodotti ed 1 processi produttivi sono progettati con criteri di eco compatibilit Il presente articolo stato prodotto in Italia The informations in this manual have been issued with care anyway LINCE ITALIA S p A will not be responsible for any errors or omissions LINCE ITALIA S p A reserves the rights to improve or modify the products described in this manual at any times and without advance notice Terms and conditions of assistance and warranty LINCE ITALIA s website www lince net our products and production process are designed with eco compatibily criteria This product is made in Italy LINCEI 2 12 1 Introduzione 1 Introduction 1 1 Generalit I rilevatori BABY sono stati sviluppati per la protezione di porte e finestre essi sono rappresentativi del pi alto livello tecnologico fra i rilevatori anti intrusione a tripla tecnologia gestiti da microprocessore Il profilo snello rende possibile l installazione tra tapparelle persiane e finestre Sono dotati di due sensori piroelettrici ed un sensore a microonde integrato sul circuito stampato Allo scopo di evitare possibili interferenze fra rilevatori installati nello stesso ambi
14. levatore dotato di una avanzato accelerometro MEMS per proteggerlo da eventuali rimozioni non autorizzate Tale funzione non disattivabile ed agisce sul morsetto normalmente chiuso denominato LINCE Dow y o Al Manual frequency Automatic frequency selection selection default A2 Frequency 1 Frequency 2 default if A1 ON Low sensibility High sensibility antimasking antimasking default A4 Low sensibility tamper Normal sensibility tamper default BEEN LEDs ON LEDs OFF after 4 minutes default CWS ON CWS OFF default CWS following the CWS following the backwards arrow downwards arrow par 2 3 6 par 2 3 6 default High PIR sensibility Low PIR sensibility default Double impulse alarm Single impulse alarm default OR of the PIR AND of the PIR default 2 3 2 LEDs This LEDs show activation of the different sensors according to the following see also the figure in par 1 4 e Red LED transmission for alarm if E e Yellow LED microwave indicator LED e Green LED sensor indicator LED When an antimasking alarm is activated all LEDs will blink slowly When an antitampering accelerometer alarm is activated all LEDs will blink rapidly LEDs can be enabled using the DIP switch 2 3 3 Antitampering accelerometer The detector is equipped with an advanced MEMS accelerometer to protect it from unauthorized removal This sensor is not disable and drives the terminal
15. n scheda rilevatore Cover with detector board Viti di chiusura imperdibili Captive clamping i screws A Praticare due fori nel muro come in figura A Drill two holes in the wall as shown in the figure B Inserire 1 tasselli in dotazione nei fori B Insert the provided plugs in the holes praticati C Fix the detector support using provided screws C Fissare il supporto del sensore usando le viti Warning to reach the IP55 enclosure degree of in dotazione Attenzione per garantire il protection the supplied gasket must be kept grado IP55 necessario lasciare montata la unchanged inside the guide on the detector bottom guarnizione presente nella guida interna della D Perform detector configuration as detailed in the base following paragraphs D Configurare il rilevatore come descritto nei E Fix the device using the captive screws retained in paragrafi successivi the detector cover E Fissarlo alla base con le viti imperdibili presenti nel coperchio del rilevatore LINCE 8 12 2 2 Cablaggio del rilevatore 2 2 Detector wiring e Appoggiare il cavo sul dente predisposto e Place the cable on the tooth present on the support della base e Pass the cable into the terminal block compartment e Passare il cavo nel vano dei morsetti through the tunnel attraverso la galleria Dente poggiacavo Cable support tooth Galleria passaggio cavo Cable tunnel e Collegare morsetti POWER una e Wire the terminal block
16. ne prolungati possibile attivare tramite 11 DIP switch B5 la funzione di allarme su doppio impulso Quando questa funzione attiva il rel di allarme verr attivato solamente quando saranno generati due rivelazioni di allarme entro 15 secondi 2 3 9 Antimascheramento solo versione AM Il rilevatore dotato di antimascheramento ad IR attivi per la protezione dei sensori piroelettrici regolabile tramite il DIP switch vedi tabella par 2 3 1 che genera un segnale di manomissione entro circa 3 minuti Questa protezione va direttamente collegata al morsetto denominato AM vedi figura par 2 2 In una installazione tipica questo morsetto deve essere collegato ad una linea attiva 24 h 3 Specifiche Tensione di alimentazione 9 15 Consumo a 12 Vcc 35 mA max Frequenza microonda Banda S Contatti di allarme tamper MOS FET relay 400 mA mascheramento 60 V 2 max Copertura rilevazione Vedi par 1 6 Funzione antimanomissione Accelerometro a 3 assi Tempo di allarme ls Antimascheramento solo su IR attivi BABY AM 4 LED di segnalazione 2 verdi 1 giallo e 1 rosso Grado protezione contenitore IP55 Classificazione ambientale Classe III EN 50131 1 2 3 7 PIR sensibility To decrease the PIR sensibility if it needs to install the detector in a hostile environment 1 e outdoor environment direct sunlight etc act on the DIP switch B4 s
17. uando un oggetto strappo dal muro viene rilevato dal sensore accelerometrico viene posto in prossimit delle lenti Il DIP switch di posizione che genera un segnale di allarme sabotaggio A3 permette di regolare questa funzione Any tampering attempt cover opening and wall pull up will When an object is placed close to the lens surface the be detected by accelerometer sensor that will generate IR Anti Masking circuit will generate a tamper tamper alarm alarm DIP switch A3 sets this function LINCEI 5 12 1 6 Determinazione area di 1 6 Determining the detection area copertura L area e la modalit di copertura deve essere Covered area it must be determined by applying the following determinata secondo la seguente procedura procedure T I i B P4 i j C 8 Non esporre alla solare diretta Do not g expose to direct sunlight Altezza height Larghezza Width Definizioni Definition Camminamento laterale Side walking Camminamento trasversale Cross walking NOTA Il BABY stato progettato per rilevare NOTE BABY detector is developed for cross walking il camminamento trasversale detection Altezza della finestra porta e Window door height La copertura massima altezza rif The maximum detector coverage height ref figure installazione A in figura pag 6 in condizioni pag 6 installation A in standard environment 25 C standard