Home

PDF – Ariston Fast Evo C

image

Contents

1. enda Cappa fumi Telaio monoblocco Scambiatore di calore Bruciatore Collettore gas Sonda acqua calda sanitaria Valvola gas Pannello di controllo Scatola scheda elettronica Scheda accensione Sensore di portata acqua Elettrodo accensione e rilevazione fiamma Termostato di sovratemperatura Sensore fumi Filtro entrata acqua fredda Uscita acqua calda Ingresso gas Entrata acqua fredda Legend Combustion Hood Frame Heat exchanger Burner Gas collector Hot water temperature sensor Gas valve Control pannel P C B box Ignition P C B Water flow switch Ignition and detection electrode Overheat thermostat Fume sensor Cold water inlet filter Hot water outler 1 2 Ingresso Gas 1 2 Cold water inlet 1 2 descrizione del prodotto product description Dimensioni Overall dimensions lt pB C f Legenda E E B Hot water outler 1 2 B Uscita acqua calda CAR C Ingresso Gas 1 2 C Ingresso gas I Lh D Cold water inlet 1 2 D Entrata acqua fredda a l ENT END Peso weight ONTC a b 1 h i j k 1 lordo netto gross net 11 113 37 87 228 5 310 54 1315 210 230 25 16 9 6 8 9 14 580 58 8 22 5 11
2. Press the On OFF button to exit from the parameter PH Close the Hot water tap Press the button 4 to select the qu parameter Press the ON OFF button to save the change The appliance switch off Checking the minimum pressure see the Gas setting table 1 2 3 4 5 Close the gas valve Loosen screw a and insert the manometer connection pipe into the pipe tap Open the gas valve Press the On Off button the display will illuminate Simultaneously press the buttons 3 and 4 for 5 seconds The display shows PR Press the 4 button to select PL Appliance forced to minimum power Open one hot water tap On the manometer verify the pressure and if necessary press the buttons 3 or 4 to adjust maximum burner pressure as indicated on the gas settings table Press the ON OFF button to exit from the parameter PL Close the Hot water tap Press the button 4 to select the 9U parameter Press the ON OFF button to save the change The appliance switch off Checking slow ignition power see the Gas setting table Ta 2 3 4 5 Close the gas valve Loosen screw a and insert the manometer connection pipe into the pipe tap Open the gas valve Press the On Off button the display will illuminate Simultaneously press the buttons 3 and 4 for 5 seconds The display shows PA Press the 4 button to select Pd Appliance forced to ignition power Open one hot water tap
3. Valva gaz Elettrodo rilevazione fiamma electrod aprindere Sensore di portata acqua Scheda principale Pannello di controllo Sonda temperatura apa calda Termostato supratemperatura e sonda fumi 0 Scheda accensione white bianco age9googg5omz Detection Electrode Ignition electrode Gas valve Water flow switch Main P C B Control pannel Outgoing water temperature sensor Overheat thermostat water and fume 0 Ignition P C B 23 messa in funzione commissioning Predisposizione al servizio Per garantire la sicurezza ed il corretto funzionamento dell apparecchio la messa in funzione deve essere eseguita da un tecnico qualificato in possesso dei requisiti di legge Alla prima accensione necessario eseguire un controllo delle regolazioni gas Alimentazione Elettrica Verificare che la tensione e la frequenza di alimentazione coincidano con i dati riportati sulla targa della caldaia Verificare l efficienza del collegamento di terra Collegare il cavo di alimentazione all apparecchio vedi figura Initial procedures To guarantee safety and the correct operation of the appliance the appliance must be prepared for operation by a qualified technician who possesses the skills which are required by law I
4. 11 Advice for the installer anneanne enneren 11 Safety regulatiors 2 neas 13 Product 15 Overall VIEW 15 Water circuit 15 DIMENSIONS ee 16 Minimum clearences 16 Thecnical data rete te rire sete ees e seit 17 Mmstalal m canu 18 Before installing the 18 Installation location 19 Gas connection nt 19 Water connection 20 View of hydraulic connections 20 Connection to a solar installation 21 Connections of flue gas discharge ducts 21 Electrical 22 Electrical CiaQram saneta dedito e re tns 23 Commisssioning nannaa 24 Ignition procedure 4 24 Electricity Supply ta teneas 24 Filling the hydraulic circuit eese 24 Gas supply isla iaia 24 First Ignition 25 Accessing the settings adjustment parameters 26 Checking the gas settings 27 Supply presure 27 Checking the ma
5. Arresto Temporaneo per anomalia evacuazione fumi Tale controllo blocca l apparecchio in caso di anomalia di evacuazione fumi Il blocco temporaneo Dopo 12 minuti l apparecchio inizia la procedura di accensione se le condizioni sono ritornate alla normalit prosegue nel funzionamento in caso contrario l apparecchio si blocca ATTENZIONE n caso di malfunzionamento o di interventi ripetuti necessario spegnere l apparecchio chiudere il rubinetto del gas togliere l alimentazione elettrica contattare il Servizio Assistenza o un tecnico qualificato per rimediare al difetto di evacuazione dei fumi verifi cando la causa del malfunzionamento In caso di intervento di manutenzione sul dispositivo utilizzare solo ricambi originali seguendo attentamente le relative istruzioni Tale dispositivo non deve mai essere messo fuori servizio in quanto ne risulterebbe compromessa la sicurezza per l utente Temporary Shut Off due to defective flue gas discharge This device causes the applaince to shut down in the event of an anomaly in the flue gas discharge The appliance shutdown is temporary After 12 minutes the aplliance begins the ignition procedure if normal conditions have been restored the appliance operates as normal If not it shuts down the appliance WARNING In the event of a malfunction or if repeated intervention is required switch the appliace off close the gas valve disc
6. Il sensore fumi non deve mai essere modificato o messo fuori servizio per non compromettere il buon funzionamento dell apparecchio Eventuali cattive condizioni di tiraggio possono provocare il riflusso di gas combusti nell ambiente di installazione Pericolo di intossicazione da monossido di carbonio La parte di canna fumaria che attraversA la parete dell abitazione dovrebbe essere ricoperta da materiale isolante ad esempio un panno amianto con spessore di almeno 11 mm e una lunghezza di 300 mm in quanto la temperatura della canna fumaria potrebbe superare la temperatura ambiente di oltre 60K Never tamper with or decommission the flue gas sensor This could affect the proper operation of the appliance Poor draught conditions could cause exhaust gas backflow into the installation room Hazard of carbon monoxide intoxication The part of flue pipe that pass through the wall of dwelling should be surrounded by insulated material such as asbestos cloth at least 11 mm thickness and 300 mm length since the temperature of flue pipe maybe exceed the ambient temperature by more than 60K 21 installazione installazione Attenzione WARNING Prima di qualunque intervento togliere Before performing any work on the appliance l alimentazione elettrica Collegamenti elettrici Per una maggiore sicurezza far effettuare da personale qualificato un controllo accurato dell impianto elettrico Il costruttore non re
7. On the manometer verify the pressure and if necessary press the buttons 3 or 4 to adjust maximum burner pressure as indicated on the gas settings table Press the ON OFF button to exit from the parameter d Close the Hot water tap Press the button 4 to select the qu parameter Press the ON OFF button to save the change The appliance switch off 28 messa in funzione commissioning Tabella riepilogativa gas Gas setting table FAST EVO ONT C 11 FAST EVO ONT C 14 G20 G230 G30 G31 G20 0230 G31 Indice di Wobbe inferiore Lower Wobbe index MJ m 45 67 38 9 80 58 70 69 45 67 38 9 80 58 70 69 15 C 1013 mbar Pressione nominale di alimentazione mbar 20 20 28 30 37 20 20 28 30 37 Gas inlet pressure Pressione massima al briciatore mbar 15 0 10 35 24 3 32 3 14 0 9 8 26 4 34 7 Gas Burner Pressure max Pressione minima al bruciatore mbar 3 0 216 4 5 6 7 22 16 3 5 50 Gas Burner Pressure min Pressione di lenta accensione mbar 4 0 34 55 83 271 20 4 1 6 0 Slow ignition pressure parametro PA Impostazione modello e gas utilizzato PA 01 04 02 03 08 11 09 10 PA Parameter Setting model and type of gas Ugelli bruciatore Main Burner jets H ie ugelli bruciatore principale mm 1 5 13 10 75 075 12 135 08 08 burner jets Consumi massimo Consumption max 2
8. Press the ON OFF button to switch ON the appliance Start the appliance by opening a D H W tap A WARNING Water with a temperature higher than 50 C can cause serious burns Always verify water temperature before use A WARNING DO NOT USE THE APPLIANCE WITHOUT WATER 25 messa in funzione commissioning Accesso ai parametri di impostazione e regolazione Per accedere ai parametri di regolazione premere contemporaneamente i tasti 3 e 4 per 3 secondi Il display visualizza PA Per selezionare altri parametri premere il tasto 4 Per accedere ai parametri premere il tasto ON OFF il display visualizza il valore del parametro Per modificare il valore premere il tasto 3 o il tasto 4 Per memorizzare la modifica premere il tasto ON OFF Accessing the settings adjustment parameters To access the parameters simultaneously press the 3 and 4 buttons for 3 seconds the display shows PA To select the others parameters press 4 button To access to the parameters press the ON OFF button the display shows the value of the parameter To modify the value press the press the 3 and 4 buttons To save the new value press ON OFF o descrizione range G note 11 It da 00 a 06 14 It da 07 a 13 16 It da 14 a 20 Selezione modello e tipo di gas PR RISERVATO AL SAT Solo in caso di sostituzione della scheda elettronica
9. Switch the appliance OFF by closing the DHW tap Close the gas valve When the check is over tighten screw b and make sure it is securely in place 8 Open the gas valve and check the tightness of the screw NO Checking the maximum pressure see the Gas setting table 1 Close the gas valve 2 Loosen screw a and insert the manometer connection pipe into the pipe tap 3 Openthe gas valve 4 Press the On Off button the display will illuminate 5 Simultaneously press the buttons 3 and 4 for 3 seconds The display shows PR 6 Press the 4 button to select PH Appliance forced to maximum power Open one hot water tap 7 On the manometer verify the pressure and if necessary press the buttons 3 or 4 to adjust maximum burner pressure as indicated on the gas settings table 27 messa in funzione commissioning 10 Premere il tasto ON OFF per uscire dal parametro e chidere il rubinetto dell acaqua calda Premere il tasto 4 per selezionare il parametro P Li Premere il tasto ON OFF per salvare le modifiche L apparecchio si spegne Controllo della pressione minima al bruciatore vedi Tabella riepilogativa gas 1 2 3 4 5 10 Chiudere il rubinetto del gas Allentare la vite a ed inserire il tubo di raccordo del manometro nella presa di pressione Aprire il rubinetto del gas Premere il tasto ON OFF Il display si illumina Premere contemporane
10. 4 disassemble and clean the burner and injector if necessary Remove oxide from the detection electrode using an emery cloth 7 Cleaning the primary heat exchanger 8 Make sure the following safety devices are operating correctly temperature limit safety device flue gas safety 9 Make sure that the following gas part safety devices are operating correctly absence of gas or flame safety device ionisation 10 Check the efficiency of the domestic hot water production process test the flow rate and temperature 11 Cleaning the filter in cold water inlet WARNING THE APPLIANCE MUST NOT BE PUT IN FUNCTION WITHOUT FILTER 12 Perform a general inspection of the aplliance operation A WARNING Never tamper with or decommission the flue gas sensor This could affect the proper operation of the appliance Poor draught conditions could cause exhaust gas backflow into the installation room Hazard of carbon monoxide intoxication 33 manutenzione maintenance Prova di funzionamento Dopo aver effettuato le operazioni di manutenzione riempire l apparecchio e l impianto sanitario Mettere in funzione l apparecchio Verificare le impostazioni e il buon funzionamento di tutti gli organi di comando regolazione e controllo Verificare la tenuta e il buon funzionamento dell impianto di evacuazione fumi prelievo aria comburente Procedura di svuotamento dell apparecchio Ogni qualvolta es
11. IMPORTANT If the unit is installed in areas with the presence of hard water 200 mg l is necessary to install a water softener to reduce the precipitation of limestone in the heat exchanger The warranty does not cover damage caused by the limestone This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance A WARNING The device must be activated only in presence of water in the exchanger manuale d uso user s manual presente libretto costituisce parte integrante ed essenziale del prodotto Deve essere conservato con cura dall utente e dovranno sempre accompagnare l apparecchio anche in caso di sua cessione ad altro proprietario o utente e o di trasferimento su altro impianto Leggere attentamente le istruzioni e le avvertenze contenute nel presente libretto in quanto forniscono importanti indicazioni riguardanti la sicurezza di installazione d uso e di manutenzione Questo apparecchio serve a produrre acqua calda per uso domestico Deve essere allacciato ad una rete di distribuzione di acqua calda sanitaria compatibilmente alle sue prestazioni ed alla sua potenza vietata l u
12. Non utilizzare detersivi aggressivi insetticidi o prodotti tossici Il rispetto delle norme vigenti permette un funzionamento sicuro ecologico e a risparmio energetico Nel caso di uso di kit od optional si dovranno utilizzare solo quelli originali Turn the appliance OFF and disconnected from the electricity supply to clean the exterior parts of the appliance Clean using a cloth dampened with soapy water Do not use aggressive detergents insecticides or toxic products If the appliance is used in full compliance with current legislation it will operate in a safe environmentally friendly and cost efficient manner If using kits or optional extras make sure they are authentic A ATTENZIONE A WARNING L acqua a temperatura superiore ai 50 C provoca gravi ustioni Verificare sempre la temperatura dell acqua prima di qualsiasi utilizzo IN ATTENZIONE IL SENSORE FUMI NON DEVE MAI ESSERE MODIFICATO O MESSO FUORI SERVIZIO PER NON COMPROMETTERE IL BUON FUNZIONAMENTO DELL APPARECCHIO EVENTUALI CATTIVE CONDIZIONI DI TIRAGGIO POSSONO PROVOCARE IL RIFLUSSO DIGASCOMBUSTINELL AMBIENTE DI INSTALLAZIONE PERICOLO DI INTOSSICAZIONE DA MONOSSIDO DI CARBONIO Water with a temperature higher than 50 C can cause serious burns Always verify water temperature before use A WARNING NEVER TAMPER WITH OR DECOMMISSION THE FLUE GAS SENSOR THIS COULD AFFECT THE PROPER OPERATION OF THE APPLIAN
13. exhausts check that these exhausts have been perfectly cleaned and are without residues because any disconnection could obstruct the passage of fumes and create potentially dangerous situations Make sure that where unsuitable flue exhausts are attached they have been ducted In areas with particularly hard water limescale may build up on the components inside the appliance and reduce its overall efficiency B11bs type appliances are open chamber versions designed to be connection to a flue gas discharge duct which releases fumes towards the outside combustion air is taken directly from inside the room in which the boiler is installed Flue gas is discharged through a natural draught system This type of appliance cannot be installed in a room that does not meet appropriate ventilation requirements So that the normal operation of the appliance is not compromised the place in which it is installed must be suitable with regard to the operating limit temperature value and the appliance should be protected so that it does not come into direct contact with atmospheric agents The appliance must be installed on a solid non combustible permanent wall to prevent access from the rear When creating a space for the boiler the minimum distances which ensure that various parts of the appliance may be accessed after it has been installed should be respected A ATTENZIONE A WARNING L installazione prima ac
14. 0 102 132 70 117 264 370 48 230 250 23 11 2 16 131 5 12 2 11 1 Distanze minime per l installazione Per permettere un agevole svolgimento delle operazioni di manutenzione dell apparecchio necessario rispettare un adeguata distanza nell installazione Posizionare l apparecchio secondo le regole della buona tecnica utilizzando una livella a bolla Minimum clearances In order to allow easy access to the appliance for maintenance operations The appliance must be installed in accordance with the clearances stated below 350 50 50 Pe 450 300 descrizione del prodotto product description Dati tecnici Technical data Nome modello Model name FAST EVO ONT C 11 ONT C 14 16 Certificazione CE pin CE Certification pin 0063CN7240 Tipo Type B11bs Categoria Gas Gas category 112H3 Portata termica massima Maximum nominal heat input kW 21 5 27 0 31 0 Portata termica minima Minimum nominal heat input kW 9 5 10 5 10 5 Potenza termica massima Maximum nominal heat output kW 19 0 24 0 27 5 Potenza termica minima Minimum nominal heat output kW 8 0 9 0 9 0 Temperatura massima acqua D H W max temperature C 65 65 65 calda Temperatura minima a
15. 28 1 76 1 70 1 67 2 86 2 22 2 13 2 10 15 C 1013 mbar G N m h LPG kg h FAST EVO ONT C 16 G20 G230 G30 G31 Indice di Wobbe inferiore Lower Wobbe index MJ m 45 67 38 9 80 58 70 69 15 C 1013 mbar Pressione nominale di alimentazione mbar 20 20 28 30 37 Gas inlet pressure Pressione massima al bruciatore mbar 11 1 10 6 21 21 28 5 Gas Burner Pressure max Pressione minima al bruciatore mbar 1 4 14 242 30 Gas Burner Pressure min Pressione di lenta accensione mbar 1 9 17 27 3 6 Slow ignition pressure parametro PA Impostazione modello e gas utilizzato PA 15 18 16 17 PA Parameter Setting model and type of gas Ugelli bruciatore Main Burner jets ai Lai ugelli bruciatore principale 13 1 35 08 burner jets Conse massimo Consumption max 3 28 2 54 2 45 2 41 15 C 1013 mbar G N m h LPG kg h Cambio Gas L apparecchio pu essere trasformato per uso da gas metano G20 a Gas Liquido G30 G31 o viceversa a cura di un Tecnico Qualificato con l utilizzo dell apposito Kit Gas Changeover The appliance may be adjusted so that it may be used with Liquid Gas G30 G31 instead of methane gas G20 or vice versa The adjustment must be performed by a Qualified Technician using the special Kit 29 sistemi di protezione appliance protection devices Sistemi di protezione L apparecchio protetto dai malfunzionamenti tramite contr
16. carried out in full conformity with the governing legal regulations and the instructions provided by the manufacturer Incorrect installation can harm persons animals and possessions the manufacturing company shall not be held responsible for any damage caused as a result In the event of a fault and or malfunction turn the appliance off turn off the gas cock disconnected it from the electricity supply and do not attempt to repair it yourself Contact a qualified professional instead All repairs which should only be performed using original spare parts should be carried out by a qualified professional Failure to comply with the above instructions could compromise the safety of the appliance and invalidate all liability on the part of the manufacturer In the event of any maintenance or other structural work in the immediate vicinity of the ducts or flue gas exhaust devices and their accessories switch the appliance off disconnected it from the electricity supply and shutting off the gas control valve When the work has been completed ask a qualified technician to check the efficiency of the ducting and the devices If the appliance should be out of use for a prolonged period it is recommended that the external gas cock be closed and disconnected it from the electricity supply If low temperatures are expected the appliance and system pipe work should be drained in order to prevent frost damage When permanently deactivating t
17. in funzione eener errr rnr re nnee 24 Predisposizione al servizio 24 Alimentazione elettrica anaana 24 Alimentazione gas ii 24 Riempimento circuito 24 Prima accensione 25 Acesso ai parametri di impostazione e regolazione 26 Verifica delle regolazioni 27 Controllo della pressione di alimentazione 27 Controllo della pressione massima al bruciatore 27 Controllo della pressione minima al bruciatore 28 Controllo della pressione di lenta accensione 28 Tabella riepilogativa gas 29 Cambio gas eem 29 Sistemi di protezione dell apparecchio 30 Tabella riepilogativa codici di errore 31 2 32 Istruzioni per l apertura della mantellatura ed ispezione dell interno renren 32 Note generali 2 2 ct ree etes 33 Prova di funzionamento 34 Procedura di svuotamento dell apparecchio 34 Istruzioni per l utente 34 Targhetta caratteristiche nerne enere eee 35 Installation and servicing instructions Only for qualified technician i re to
18. vedi tabella regolazione gas BH Regolazione pressione massima al bruciatore PL Regolazione pressione minima al bruciatore Pd Regolazione Lenta accensione Parametro per tornare alla normale a visualizazione e salvataggio delle Premere il tasto ON OFF modifiche apportate de 2 S description value notes 11 It from 00 to 06 Model and type ofgas 4 4 It from 07 to 13 p A selection 16 It from 14 to 20 RESERVED FOR TECHNICAL ASSISTANCE Only if the gas or PCB is changed see gas setting table PH Adjust the Gas burner pressure MAX Adjust the Gas burner pressure MIN Pd Adjust theSlow ignition pressure Use this parameter to exit and save all modification Push the ON OFF button 26 messa in funzione commissioning Checking the gas settings Verifica della regolazione gas Controllo della pressione di alimentazione 1 Chiudere il rubinetto gas 2 Allentare la vite b ed inserire il tubo di raccordo del manometro nella presa di pressione 3 Aprire il rubinetto del gas 4 Mettere l apparecchio in funzione aprendo un rubinetto dell acqua calda sanitaria La pressione di alimentazione deve corrispondere a quella prevista per il tipo di gas per cui l apparecchio predisposto A ATTENZIONE Se la pressione di alimentazione non corrisponde a quanto indicato nella
19. CE POOR DRAUGHT CONDITIONS COULD CAUSE EXHAUST GAS BACKFLOW INTO THE INSTALLATION ROOM HAZARD OF CARBON INTOXICATION MONOXIDE A ATTENZIONE A WARNING L apparecchio pu essere utilizzato solo con presenza di acqua nello scambiatore The device must be activated only in presence of water in the exchanager generalita overview Norme di sicurezza Legenda simboli rischio di lesioni in determinate circostanze anche mortali per le persone Il mancato rispetto dell avvertenza comporta A Il mancato rispetto dell avvertenza comporta rischio di danneggiamenti in determinate circostanze anche gravi per oggetti piante o animali Installare l apparecchio su parete solida non soggetta a vibrazioni A Rumorosit durante il funzionamento Non danneggiare nel forare la parete cavi elettrici o tubazioni preesistenti A Folgorazione per contatto con conduttori sotto tensione Esplosioni incendi o intossicazioni per perdita gas dalle tubazioni danneggiate x Danneggiamento impianti preesistenti Allagamenti per perdita acqua dalle tubazioni danneggiate Eseguire i collegamenti elettrici con conduttori di sezione adeguata A Incendio per surriscaldamento dovuto al passaggio di corrente elettrica in cavi sottodimensionati Proteggere tubi e cavi di collegamento in modo da evitare il loro danneggiamento A Folgorazione per contatto con conduttori sotto tensione Esplosioni in
20. FAST EVO Manuale d uso per l utente User s manual Istruzioni tecniche per l installazione e la manutenzione Installation and Servicing instructions SCALDABAGNO ISTANTANEO A GAS TIPO B11bs GAS WATER HEATER TYPE B11bs FAST EVO ONT C 11 FAST EVO ONT C 14 FAST EVO ONT C 16 Istruzioni d uso per l utente Avvertenze generali rees 4 Norme di SIGUFIeZz ted ent ter b ea ecce tis 5 Pannello di controllo 6 Procedura di accensione 7 Regolazione della temperatura dell acqua 7 Procedura di 7 Condizioni di arresto dell apparecchio 8 Protezione antigelo i crati sile ehi 9 Cambio Gas ea aaa 9 MANUTENZIONE scorrerie 9 Marcatura CE Il marchio CE garantisce la rispondenza dell apparecchio alle seguenti direttive 2009 142 CE relativa agli apparecchi a gas 2004 108 EC relativa alla compatibilit elettromagnetica 2006 95 EC relativa alla sicurezza elettrica User s instructions General warnings ana Safety regulations sssini Control panel rre aaa aa Ignition pFOCGdUre siria Power appliance ans Water temperature adjtment Switchinf off procedure ar Appliance shut off CONditions reenen Anti freeze protection nees Change gas type be ila Maintenanc
21. N Ignition procedure ensure that the cock located on the cold water fitting is open ensure that the gas cock is open press the ON OFF button the display will illuminate The device is ready to operate By opening a tap the device automatically starts operating The display shows the temperature and the symbol Note If the device does not operate ensure that the gas and or cold water cocks are open Ensure that the device is electrically powered When closing the tap the device automatically switches off A WARNING Water with a temperature higher than 50 C can cause serious burns Always verify water temperature before use Power appliance and Water temperature adjustment The buttons 4 and 3 lets you adjust the water temperature and power Press the button 4 to increase power and temperature Press the button 3 to decrease power and temperature It s possible to increase the temperature until 55 C To select high temperatures push the button 4 for three seconds The display shows 56 C and pressing the button 4 again to select the desired temperature up to a maximum of 65 C Switching off procedure Press the ON OFF button the display will switch off To switch off the device completely switch off close the gas isolation valve and disconnected from the electricity supply manuale d uso user s manual Condizioni di arresto dell appa
22. Tabella Riepilogativa Gas NON METTERE IN FUNZIONE L APPARECCHIO 5 Spegnere l apparecchio chiudendo il rubinetto dell acqua calda sanitaria 6 Chiudere il rubinetto del gas 7 Staccare il manometro e stringere la vite b 8 Aprire il rubinetto del gas e verificare la tenuta della vite di misurazione Controllo della pressione massima al bruciatore vedi Tabella riepilogativa gas 1 Chiudere il rubinetto del gas 2 Allentare la vite a ed inserire il tubo di raccordo del manometro nella presa di pressione 3 Aprire il rubinetto del gas 4 Premere il tasto ON OFF Il display si illumina 5 Premere contemporaneamente i tasti 3 e 4 per 3 secondi il display visualizza 6 Premere il taso 4 per selezionare PH L apparecchio forzato alla massima potenza Aprire un rubinetto dell acqua calda Verificare sul manometro la pressione e se necessario modificarla premendo i tasti 3 o 4 come indicato nella tabella riepilogativa gas Supply pressure check 1 Close the gas valve 2 Loosen screw b and insert the pressure gauge connection pipe into the pipe tap 3 Open the gas valve 4 Switch the appliance ON by opening a DHW tap The supply pressure should correspond to the value established in relation to the type of gas for which the appliance is designed A WARNING Should the power pressure not correspond to what indicated on the Gas Summary Table DO NOT ACTIVATE THE DEVICE
23. ace Do not climb onto chairs stools ladders or unstable supports to clean the appliance A Leziuni personale provocate de c dere sc ri duble Do not attempt to clean the appliance without first switching it off and turning the external switch to the OFF position A Electrocution from live components Do not use insecticides solvents or aggressive detergents to clean the appliance Damage to plastic and painted parts Do not use the appliance for any use other than normal domestic use A Damage to the appliance caused by operation overload Damage caused to objects treated inappropriately Do not allow children or inexperienced individuals to operate the appliance 7X Damage to the appliance caused by improper use If you detect a smell of burning or smoke coming from the appliance disconnect it from the electricity supply turn off the main gas valve open all windows and call for assistance A Personal injury caused by burns smoke inhalation intoxication If there is a strong smell of gas turn off the main gas valve open all windows and call for assistance A Explosions fires or intoxication manuale d uso user s manual ATTENZIONE L installazione la prima accensione le regolazioni di manutenzione devono essere effettuate secondo le istruzioni esclusivamente da personale qualificato Un errata installazione pu causare danni a persone animali o cose nei confronti dei quali il c
24. all doors and windows Make sure there are no sparks or naked flames in the room Make sure that the system does not leak fuel using a cut off valve inside the applianceitself which should be closed and then opened while the gas valve is disabled The meter must not show any signs of gas being used for 10 minutes 24 messa in funzione commissioning Prima accensione La prima accensione deve essere eseguita da un tecnico qualificato inoltre necessario effettuare un controllo delle impostazioni gas Assicurarsi che il rubinetto gas sia aperto il condotto di evacuazione dei prodotti della combustione sia idoneo e libero da eventuali ostruzioni le necessarie prese di ventilazione del locale siano aperte installazioni di tipo B Premere il pulsante ON OFF il display si illuimina Aprire un rubinetto dell acqua calda sanitaria A ATTENZIONE L acqua a temperatura superiore ai 50 C provoca gravi ustioni Verificare sempre la temperatura dell acqua prima di qualsiasi utilizzo A ATTENZIONE L APPARECCHIO PU ESSERE UTILIZZATO SOLO CON PRESENZA DI ACQUA NELLO SCAMBIATORE First ignition The first start up must be carried out by a qualified technician Make sure that The gas valve is closed the exhaust duct for combustion products should be suitable and free from any obstructions Any necessary ventilation inlets in the room should be open type B installation
25. amente i tasti 3 e 4 per 5 secondi il display visualizza Premere il taso 4 per selezionare PL L apparecchio forzato alla minima potenza Aprire un rubinetto dell acqua calda Verificare sul manometro la pressione e se necessario modificarla premendo i tasti 3 o 4 come indicato nella tabella riepilogativa gas romere il tasto ON OFF per uscire dal parametro L e chidere il rubinetto dell acaqua calda remera il tasto 4 per selezionare il parametro Premere il tasto ON OFF per salvare le modifiche L apparecchio si spegne Controllo della pressione di lenta accensione vedi Tabella riepilogativa gas 1 2 3 4 5 10 Chiudere il rubinetto del gas Allentare la vite a ed inserire il tubo di raccordo del manometro nella presa di pressione Aprire il rubinetto del gas Premere il tasto ON OFF Il display si illumina Premere contemporaneamente i tasti 3 e 4 per 5 secondi il display visualizza Premere il taso 4 per selezionare Pd L apparecchio forzato alla potenza di accensione Aprire un rubinetto dell acqua calda Verificare sul manometro la pressione e se necessario modificarla premendo i tasti 3 o 4 come indicato nella tabella riepilogativa gas Premere il tasto ON OFF per uscire dal parametro e chidere il rubinetto dell acaqua calda Premere il tasto 4 per selezionare il parametro re LI Premere il tasto ON OFF per salvare le modifiche L apparecchio si spegne 8
26. apparecchio o degli oggetti sottostanti per la caduta dell oggetto a seguito di vibrazioni Non salire sull apparecchio A Lesioni personali per la caduta dell apparecchio A Danneggiamento dell apparecchio o degli oggetti sottostanti per la caduta dell apparecchio a seguito del distacco dal fissaggio Non salire su sedie sgabelli scale o supporti instabili per effettuare la pulizia dell apparecchio A Lesioni personali per la caduta dall alto o per cesoiamento scale doppie Non effettuare operazioni di pulizia dell apparecchio senza aver prima spento l apparecchio e portato l interruttore esterno in posizione OFF A Folgorazione per presenza di componenti sotto tensione Non utilizzare insetticidi solventi o detersivi aggressivi per la pulizia dell apparecchio A Danneggiamento delle parti in materiale plastico o verniciate Non utilizzare l apparecchio per scopi diversi da quello di un normale uso domestico A Danneggiamento dell apparecchio per sovraccarico di funzionamento Danneggiamento degli oggetti indebitamente trattati Non fare utilizzare l apparecchio da bambini o persone inesperte A Danneggiamento dell apparecchio per uso improprio Nel caso si avverta odore di bruciato o si veda del fumo fuoriuscire dall apparecchio spegnere l apparecchio chiudere il rubinetto principale del gas aprire le finestre ed avvisare il tecnico A Lesioni personali per ustioni intossicazione Nel caso si avverta
27. aters are designed to function either with Natural Gas methane or L P G gas If you need to change from one gas to the other one of our Authorised Service Centres must be contacted to convert the appliance Maintenance Schedule an annual maintenance check up for the appliance with a competent person Correct maintenance always results in savings in the cost of running the system Istruzioni tecniche per l installazione e la manutenzione riservato al tecnico qualificato Generalit o e 11 Avvertenze per l installatore reene 11 Norme di SICUFGZZ it ee etd stents 13 Descrizione del prodotto 15 Vista complessiva sss 15 Schema idraulico 2 ertet 15 DIMENS ON e EET 15 Distanze minime per l installazione 16 BERT 17 Installazione eee ee ranee rrn rneee rennene 18 Avvertenze prima dell installazione 18 Luogo di installazione 19 Collegamento Gas 19 Collegamento 20 Vista dei raccordi idraulici eneee nerne nennen 20 Collegamento impianto 21 Collegamento condotti scarico fumi 21 Collegamenti elettrici 22 Schema elettrico sss 23 Messa
28. azioni A Lesioni personali per la caduta dall alto Safety regulations Key to symbols risk of personal injury in some circumstances Failure to comply with this warning implies the even fatal A Failure to comply with this warning implies the risk of damage in some circumstances even serious to property plants or animals Install the appliance on a solid wall which is not subject to vibration A Noisiness during operation When drilling holes in the wall for installation purposes take care not to damage any electrical wiring or existing piping A Electrocution caused by contact with live wires Explo sions fires or asphyxiation caused by gas leaking from damaged piping A Damage to existing installations Flooding caused by wa ter leaking from damaged piping Perform all electrical connections using wires which have a suitable section A Fire caused by overheating due to electrical current pas sing through undersized cables Protect all connection pipes and wires in order to prevent them from being damaged A Electrocution caused by contact with live wires Explo sions fires or asphyxiation caused by gas leaking from damaged piping A Flooding caused by water leaking from damaged piping Make sure the installation site and any systems to which the appliance must be connected comply with the applica ble norms in force A Electrocution caused by contact with live wires which have been installed in
29. binetto del gas dell acqua dell impianto sanitario e rimuovere le batterie Al termine vanno ripristinate le regolazioni iniziali Note Generali Si raccomanda di effettuare sull apparecchio almeno una volta l anno i seguenti controlli 1 Controllo delle tenute della parte acqua con eventuale sostituzione delle guarnizioni e ripristino della tenuta 2 Controllo delle tenute della parte gas con eventuale sostituzione delle guarnizioni e ripristino della tenuta 3 Controllo visivo dello stato complessivo dell apparecchio 4 Controllo visivo della combustione ed eventuale smontaggio e pulizia del bruciatore 5 A seguito del controllo al punto 3 eventuale smontaggio e pulizia della camera di combustione 6 A seguito del controllo al punto 4 eventuale smontaggio e pulizia del bruciatore e dell iniettore 7 Pulizia dello scambiatore di calore primario 8 Verifica del funzionamento dei sistemi di sicurezza riscaldamento sicurezza temperatura limite sicurezza fumi 9 Verifica del funzionamento dei sistemi di sicurezza parte gas sicurezza mancanza gas o fiamma ionizzazione 10 Controllo dell efficienza della produzione di acqua sanitaria verifica della portata e della temperatura 11 Pulizia del filtro in ingresso acqua fredda ATTENZIONE L APPARECCHIO NON DEVE ESSERE MESSO IN FUNZIONE SENZA FILTRO 12 Controllo generale del funzionamento dell apparecchio 13 Rimozione dell ossido dall elettro
30. cendi o intossicazioni per perdita gas dalle tubazioni danneggiate A Allagamenti per perdita danneggiate Assicurarsi che l ambiente di installazione e gli impianti a cui deve connettersi l apparecchiatura siano conformi alle normative vigenti A Folgorazione per contatto con conduttori sotto tensione incorrettamente installati A Danneggiamento dell apparecchio per condizioni di funzionamento improprie Adoperare utensili ed attrezzature manuali adeguati all uso in particolare assicurarsi che l utensile non sia deteriorato e che il manico sia integro e correttamente fissato utilizzarli correttamente assicurarli da eventuale caduta dall alto riporli dopo l uso A Lesioni personali per proiezione di schegge o frammenti inalazione polveri urti tagli punture abrasioni rumore vibrazioni A Danneggiamento dell apparecchio o di oggetti circostanti per proiezione di schegge colpi incisioni Assicurarsi che le scale portatili siano stabilmente appoggiate che siano appropriatamente resistenti che i gradini siano integri e non scivolosi che non vengano spostate con qualcuno sopra che qualcuno vigili A Lesioni personali per la caduta dall alto o per cesoiamento scale doppie Assicurarsi che le scale a castello siano stabilmente appoggiate che siano appropriatamente resistenti che i gradini siano integri e non scivolosi che abbiano mancorrenti lungo la rampa e parapetti sul pianerottolo acqua dalle tub
31. censione la manutenzione e la riparazione dell apparecchio devono essere effettuate da personale qualificato in conformit alle normative nazionali di installazione in vigore e ad eventuali prescrizioni delle autorit locali e di enti preposti alla salute pubblica The installation and first ignition of the appliance must be performed by qualified personnel in compliance with current national regulations regarding installation and in conformity with any requirements established by local authorities and public health organisations 18 installazione installazione A ATTENZIONE A WARNING Nessun oggetto infiammabile deve trovarsi nelle vicinanze della dell apparecchio Assicurarsi che l ambiente di installazione e gli impianti a cui deve connettersi l apparecchio siano conformi alle normative vigenti Se nel locale di installazione sono presenti polveri e o vapori aggressivi l apparecchio deve funzionare indipendentemente dall aria del locale Luogo di installazione Nella scelta del luogo di installazione dell apparecchio rispettare le disposizioni delle Norme in vigore L apparecchio deve essere installato in POSIZIONE PERFETTAMENTE VERTICALE L apparecchio non pu essere installato nelle vicinanze di una fonte di calore Non installare lapparecchio in ambienti dove la temperatura possa scendere fino a 0 C Per installazioni all interno di mobili considerare che la temperatura massi
32. co qualificato la manutenzione ordinaria Temporary Shut Off due to defective flue gas discharge This device causes the applaince to shut down in the event of an anomaly in the flue gas discharge The appliance shutdown is temporary After 12 minutes the aplliance begins the ignition procedure if normal conditions have been restored the appliance operates as normal If not the appliance shuts down WARNING In the event of a malfunction or if repeated intervention is required switch the appliace off close the gas valve disconnected from the electricity supply contact the Technical Assistance Service or a qualified technician in order to repair the flue gas discharge fault once the cause of the malfunction is detected Whenever maintenance work is performed on the device use original spare parts only and follow the relative instructions carefully Anti freeze protection Should the appliance be installed where pipes are subjected to freezing it is recommended to empty it Proceed as indicated below Press the ON OFF button to switch off the appliance Disconnected from the electricity supply Close the cold water inlet isolation valve Open the DHW taps until both the appliance and pipes are completely emptied To fill the appliance again open the cold water inlet isolation valve together with DHW taps until water flows steadily from all taps Change of gas type Our instantaneous water he
33. correctly A Damage to the appliance caused by improper operating conditions Use suitable manual tools and equipment make sure in particular that the tool is not worn out and that its handle is fixed properly use them correctly and make sure they do not fall from a height Replace them once you have finished using them A Personal injury from the falling splinters or fragments in halation of dust shocks cuts pricks and abrasions A Damage to the appliance or surrounding objects caused by falling splinters knocks and incisions Make sure any portable ladders are positioned securely that they are suitably strong and that the steps are intact and not slippery and do not wobble when someone climbs them Ensure someone provides supervision at all times A Personal injury caused by falling from a height or cuts stepladders shutting accidentally Make sure any rolling ladders are positioned securely that they are suitably strong that the steps are intact and not slippery and that the ladders are fitted with handrails on either side of the ladder and parapets on the landing A Personal injury caused by falling from a height 13 generalita overview Assicurarsi durante i lavori eseguiti in quota in genere con dislivello superiore a due metri che siano adottati parapetti perimetrali nella zona di lavoro o imbragature individuali atti a prevenire la caduta che lo spazio percorso durante l eventuale caduta sia lib
34. cqua calda D H W min temperature C 35 35 35 Portata nominale acqua D H W Nominal flow rate l min 11 14 16 Portata minima acqua calda D H W Minimum flow rate l min 22 23 23 Pressione acqua massima Water pressure maximum 10 10 10 ammessa Pressione acqua minima Water pressure minimum bar gt 0 1 gt 0 1 gt 0 1 ammessa Portata necessaria aria per Required flow rate combustion combustione air m3 h 35 9 45 4 45 8 Temperatura fumi alla portata Flue fumes temperature at C 190 190 190 termica minima Minimum nominal heat input Portata massica fumi massima MAX capacity fumes G20 g s 13 4 16 9 17 5 Temperatura minima di Minimum operating room C 5 5 5 funzionamento temperature Dimensioni Dimensions Altezza Height mm 580 580 580 Larghezza Width mm 310 370 370 Profondita Depth mm 210 210 230 Tensione frequenza di Power supply voltage frequency V Hz 230 50 alimentazione Consumo elettrico Power consumption V 1 5 installazione installazione Avvertenze prima dell installazione L apparecchio serve a riscaldare lacqua ad una temperatura inferiore a quella di ebollizione Esso deve essere allacciato ad una rete di acqua sanitaria dimensionata in base alle sue prestazione ed alla sua potenza Prima di collegare l apparecchio necessario effettuare un lavaggio accurato delle tubazioni degli impianti per rimuovere eventuali residui di filettature saldature o sporcizie che possano compromettere i
35. cqua calda l apparecchio si mette in funzione automaticamente Sul display viene visualizzato il simbolo Nota Se lapparecchio non si mette in funzione verificare che il rubinetto del gas e o dell acqua fredda siano aperti Verificare la connessione elettrica Non appena il rubinetto viene chiuso l apparecchio si spegne automaticamente A ATTENZIONE L acqua a temperatura superiore ai 50 C provoca gravi ustioni Verificare sempre la temperatura dell acqua prima di qualsiasi utilizzo Regolazione della potenze e della temperatura dell acqua L apparecchio consente di impostare una temperatura dell acqua costante indipendentemente dalla quantit del prelievo Tramite i pulsanti 4 e 3 possibile regolare la potenza e la temperatura dell acqua premendoil pulsante 4 si aumenta la potenza e la temperatura premendoilpulsante 3 si diminuisce la potenza e la temperatura E possibile incrementare la temperatura fino a 55 C Per selezionare alte temperature necessario tenere premuto il tasto 4 per tre secondi Suldisplay compare 56 continuare a premere il pulsante 4 per selezionare la temperatura desiderata fino ad un massimo di 65 C Procedura di spegnimento Per spegnere l apparecchio premere il tasto ON OFF il display si spegne Per spegnere completamente l apparecchio chiudere il rubinetto del gas e togliere l alimentazione elettrica ARISTON ARISTO
36. do di rilevazione tramite tela smeriglio A ATTENZIONE Il sensore fumi non deve mai essere modificato messo fuori servizio per non compromettere il buon funzionamento dell apparecchio Eventuali cattive condizioni di tiraggio possono provocare il riflusso di gas combusti nell ambiente di installazione Pericolo di intossicazione da monossido di carbonio Maintenance is an essential part of the safe and efficient operation of the appliance and ensures its durability It should be performed according to the instructions given in current legislation Before beginning maintenance work Disconnected from the electricity supply Close the gas valve and the domestic hot water System valve After the work has been completed the initial settings will be restored General comments It is recommended that the following inspections be carried out on the appliance at least once a year 1 Visually check the overall condition of the appliance 2 Check the seals in the water part and if necessary replace the gaskets and restore the seal to perfect working order 3 Check the seals in the gas part and if necessary replace the gaskets and restore the seal to perfect working order 4 Visually check the combustion and if necessary disassemble and clean the burner 5 Following the inspection detailed in point 3 disassemble and clean the combustion chamber if necessary 6 Following the inspection detailed in point
37. e arcaica CE labelling The CE mark guarantees that the appliance conforms to the following directives 2009 142 CEE relating to gas appliances 2004 108 EC relating to electromagnetic compatibility 2006 95 EC relating to electrical safety manuale d uso user s manual Egregio Signore desideriamo ringraziarLa per aver preferito nel suo acquisto un apparecchio di ns produzione Siamo certi di averLe fornito un prodotto tecnicamente valido Questo libretto stato preparato per informarLa con avvertenze e consigli sulla sua installazione il suo uso corretto e la sua manutenzione per poterne apprezzare tutte le qualit Conservi con cura questo libretto per ogni ulteriore consultazione Il nostro servizio tecnico di zona rimane a Sua completa disposizione per tutte le necessit GARANZIA Per beneficiare della garanzia necessario contattare il Centro Assistenza ARISTON di zona entro 3 mesi dalla data di installazione dell apparecchio Verificato il buon funzionamento il Centro Assistenza ARISTON Le fornir tutte le informazioni per il suo corretto utilizzo e proceder all attivazione della Garanzia ARISTON consegnandoLe copia dell apposita cartolina Per avere il numero di telefono del Centro Assistenza pi vicino pu chiamare il Numero Unico 199 111 222 Dear Customer Thank you for choosing an ARISTON gas water heater We guarantee that your instantaneous water heater is a reliabl
38. e and technically sound product This manual provides detailed instructions and recommendations for proper installation use and maintenance Remember to keep this manual in a safe place for future reference i e by the gas meter Your local ARISTON Servicing Centre is at your complete disposal for all requirements IN ATTENZIONE IN WARNING L acqua a temperatura superiore ai 50 C provoca gravi ustioni Verificare sempre la temperatura dell acqua prima di qualsiasi utilizzo IMPORTANTE Se l apparecchio viene installato in zone con presenza di acqua dura gt 200 mg l e necessario installare un addolcitore per limitare la precipitazione di calcare nello scambiatore La garanzia non copre i danni causati dal calcare L apparecchio non destinato a essere utilizzato da persone bambini compresi le cui capacit fisiche sensoriali o mentali siano ridotte oppure con mancanza di esperienza o di conoscenza a meno che esse abbiano potuto beneficiare attraverso l intermediazione di una persona responsabile della loro sicurezza di una sorveglianza o di istruzioni riguardanti l uso dell apparecchio bambini devono essere sorvegliati per sincerarsi che non giochino con l apparecchio A ATTENZIONE L apparecchio pu essere utilizzato solo con presenza di acqua nello scambiatore Water with a temperature higher than 50 cause serious burns Always verify water temperature before use
39. er with a temperature higher than 50 C can cause serious burns Always verify water temperature before use A ATTENZIONE A WARNING L APPARECCHIO PU ESSERE UTILIZZATO SOLO CON PRESENZA DI ACQUA NELLO SCAMBIATORE DO NOT USE THE APPLIANCE WITHOUT WATER 30 sistemi di protezione appliance protection devices Tabella errori Table summarising error Codice iL Error ome Descrizione Description 1 Controllare se il 1 Check the cable cavo del sensore Water of the temperature Sensore di e collegato E2 temperature probe 2 temperatura correttamente sensor failure 2 Check the water difettoso 2 Verificare se la pressure too low pressione acqua e troppo bassa 1 Check the gas 1 Controllare che il lenition failure or cock tubo di ingresso E3 left 2 Check the position Mancata gas non sia of the detection accensione dopo intercettato electrode E3 corretta 2 Verificare che scarica di l elettrodo di Gs valve Check if the gas scintilla rilevazione fiamma E4 defective diaphram is not posizionato 1 Check for Controllare che il a possible E4 i 9 diaframma gas E5 Guai obstruction of the difettosa flue sia ostruito o bloccato Check the water 1 Controllare pressure too low una eventuale ostruzione dello scarico fumi E5 Sovratemperatura 2 Verificare che la pressione acqua non sia troppo bassa
40. ero da ostacoli pericolosi che l eventuale impatto sia attutito da superfici di arresto semirigide o deformabili A Lesioni personali per la caduta dall alto Assicurarsi che il luogo di lavoro abbia adeguate condizioni igienico sanitarie in riferimento all illuminazione all aerazione alla solidit A Lesioni personali per urti inciampi ecc Proteggere con adeguato materiale l apparecchio e le aree in prossimit del luogo di lavoro A Danneggiamento dell apparecchio di oggetti circostanti per proiezione di schegge colpi incisioni Movimentare l apparecchio con le dovute protezioni e con la dovuta cautela A Danneggiamento dell apparecchio di oggetti circostanti per urti colpi incisioni schiacciamento Indossare durante le lavorazioni gli indumenti e gli equipaggiamenti protettivi individuali Lesioni personali per folgorazione proiezione di schegge A o frammenti inalazioni polveri urti tagli punture abrasioni rumore vibrazioni Organizzare la dislocazione del materiale e delle attrezzature in modo da rendere agevole e sicura la movimentazione evitando cataste che possano essere soggette a cedimenti o crolli A Danneggiamento dell apparecchio di oggetti circostanti per urti colpi incisioni schiacciamento Le operazioni all interno dell apparecchio devono essere eseguite con la cautela necessaria ad evitare bruschi contatti con parti acuminate A Lesioni personali per tagli puntu
41. esponsabilit del costruttore Nel caso di lavori o manutenzioni di strutture poste nelle vicinanze dei condotti o dei dispositivi di scarico dei fumi e loro accessori mettere fuori servizio l apparecchio chiudendo il rubinetto del gas e togliere l alimentazione elettrica A lavori ultimati far verificare l efficienza dei condotti e dei dispositivi da personale tecnico qualificato A Advice for the installer The installation and first ignition of the applaiance must be performed by qualified personnel in compliance with current national regulations regarding installation and in conformity with any requirements established by local authorities and public health organisations This appliance is designed to produce hot water for domestic use It should be connected to a distribution network for domestic hot water that must be compatible with its performance and power levels The use of the appliance for purposes other than those specified is strictly forbidden The manufacturer cannot be held responsible for any damage caused by improper incorrect and unreasonable use of the appliance or by the failure to comply with the instructions given in this manual Installation maintenance and all other interventions must be carried out in full conformity with the governing legal regulations and the instructions provided by the manufacturer Incorrect installation can harm persons animals and possessions the manufacturing company shall
42. forte odore di gas chiudere il rubinetto principale del gas aprire le finestre ed avvisare il tecnico A Esplosioni incendi o intossicazioni inalazione fumi Safety regulations Failure to comply with this warning implies the risk of personal injury in some circumstances even fatal Failure to comply with this warning implies the risk of damage in some circumstances even serious to property plants or animals Do not perform operations which involve opening the appliance A Electrocution from live components Personal injury caused by burns due to overheated components or wounds caused by sharp edges or protrusions Do not perform operations which involve removing the appliance from its installation space A Electrocution from live components Flooding caused by water leaking from disconnected iping A fires or intoxication caused by gas leaking from disconnected piping Do not damage the power supply cable A Electrocution from live uninsulated wires Do not leave anything on top of the appliance A Personal injury caused by an object falling off the appliance as a result of vibrations A Damage to the appliance or items underneath it caused by the object falling off as a result of vibrations Do not climb onto the appliance A Personal injury caused by the appliance falling A Damage to the appliance or any objects underneath it caused by the appliance falling away from its installation sp
43. he appliance make sure that the operations are carried out by qualified technical professional Turn the appliace off and disconnected it from the electricity supply to clean the exterior parts of the appliance No inflammable items should be left or used in the vicinity oh the appliance manuale d uso user s manual Norme di sicurezza Legenda simboli Il mancato rispetto dell avvertenza comporta rischio di lesioni in determinate circostanze anche mortali per le persone I mancato rispetto dell avvertenza comporta rischio di danneggiamenti in determinate circostanze anche gravi per oggetti piante o animali Non effettuare operazioni che implichino l apertura dell apparecchio A Folgorazione per presenza di componenti sotto tensione Lesioni personali per ustioni per presenza di componenti surriscaldati o per ferite per presenza di bordi e protuberanze taglienti Non effettuare operazioni che implichino la rimozione dell apparecchio dalla sua installazione A Folgorazione per presenza di componenti sotto tensione Esplosioni incendi o intossicazioni per perdita gas dalle tubazioni scollegate A Allagamenti per perdita acqua dalle scollegate Non danneggiare il cavo di alimentazione elettrica A Folgorazione per presenza di fili scoperti sotto tensione tubazioni Non lasciare oggetti sull apparecchio A Lesioni personali per la caduta dell oggetto a seguito di vibrazioni A Danneggiamento dell
44. ica contattare il Servizio Assistenza o un tecnico qualificato per rimediare al difetto di evacuazione dei fumi verifi cando la causa del malfunzionamento In caso d i intervento di manutenzione sul dispositivo utilizzare solo ricambi originali seguendo attentamente le relative istruzioni Tale dispositivo non deve mai essere messo fuori servizio in quanto ne risulterebbe compromessa la sicurezza per l utente Protezione antigelo Se l apparecchio installato in un luogo dove le tubazioni sono a rischio di gelo si consiglia di svuotarlo Procedere come sotto indicato Spegnere l apparecchio premendo il tasto ON OFF Chiudere il rubinetto di intercettazione del gas Togliere l alimentazione elettrica Chiudere il rubinetto di entrata acqua fredda Aprire i rubinetti dell acqua calda sanitaria fino a completo svuotamento dell apparecchio e delle tubazioni Perriempire nuovamente l apparecchio aprire il rubinetto sull entrata fredda ed aprire i rubinetti dell acqua calda sanitaria fino a che esce acqua Cambio Gas L apparecchio pu essere trasformato per uso da gas metano G20 a Gas Liquido G31 o viceversa a cura di un Tecnico Qualificato con l utilizzo dell apposito Kit Manutenzione La manutenzione essenziale per la sicurezza il buon funzionamento e la durata dell apparecchio Va effettuata in base a quanto previsto dalle norme vigenti E consigliabile far eseguire annualmente da un tecni
45. ista pericolo di gelo deve essere svuotato l impianto sanitario nel seguente modo chiudere il rubinetto della rete idrica aprire tutti i rubinetti dell acqua calda ATTENZIONE Svuotare i componenti che potrebbero contenere acqua calda attivando eventuali sfiati prima della loro manipolazione Effettuare la disincrostazione da calcare di componenti attenendosi a quanto specificato nella scheda di sicurezza del prodotto usato aerando l ambiente indossando indumenti protettivi evitando miscelazioni di prodotti diversi proteggendo l apparecchio e gli oggetti circostanti Richiudere ermeticamente le aperture utilizzate per effettuare letture di pressione gas o regolazioni gas Accertarsi che gli ugelli siano compatibili con il gas di alimentazione Nel caso si avverta odore di bruciato o si veda del fumo fuoriuscire dall apparecchio o si avverta forte odore di gas togliere l alimentazione elettrica chiudere il rubinetto del gas aprire le finestre ed avvisare il tecnico Informazioni per l Utente Informare l utente sulla modalit di funzionamento dell apparecchio In particolare consegnare all utente il manuale di istruzione informandolo che deve essere conservato a corredo dell apparecchio Inoltre far presente all utente quanto segue Come impostare la temperatura ed i dispositivi di regolazione per una corretta e pi economica gestione dell apparecchio Far eseguire come da normativa la manutenzione pe
46. l corretto funzionamento dell apparecchio verificare la predisposizione dell apparecchio per il funzionamento con il tipo di gas disponibile leggere quanto riportato sull etichetta dell imballo e sulla targhetta caratteristiche controllare che la canna fumaria non presenti strozzature e non vi siano collegati scarichi di altri apparecchi salvo che questa sia stata realizzata per servire pi utenze secondo quanto previsto dalle Norme vigenti controllare che nel caso di raccordo su canne fumarie preesistenti queste siano state perfettamente pulite e non presentino scorie in quanto l eventuale distacco delle stesse potrebbe ostruire il passaggio dei fumi causando situazioni di pericolo controllare che nel caso di raccordo su canne fumarie non idonee queste siano state intubate in presenza di acque con durezza particolarmente elevata si avr rischio di accumulo di calcare con conseguente diminuzione di efficienza dei componenti dell apparecchio Gli apparecchi tipo B sono apparecchi a camera aperta previsti per essere collegati ad un condotto di evacuazione dei prodotti della combustione verso l esterno del locale l aria comburente prelevata direttamente nell ambiente in cui la caldaia installata Lo scarico dei fumi a tiraggio naturale Questo tipo di apparecchio non pu essere installato in un locale che non risponde alle appropriate prescrizioni di ventilazione Per non compromettere il regolare fu
47. ma del mantello dell apparecchio inferiore a 85 C e che vengano rispettate le distanze minime necessarie per la manutenzione Collegamento gas L apparecchio stato progettato per utilizzare gas appartenenti alle categorie come riportato sulla seguente tabella No inflammable items should be left in the vicinity of the appliance Make sure the installation site and any systems to which the appliance must be connected are fully compliant with the current applicable legislation If dust and or aggressive vapours are present in the room in which it is to be installed the appliance must operate independently of the air inside the room Installation location Observe the regulations in force when deciding where to install the device Install the appliance in a PERFECTLY VERTICAL POSITION The device must not be installed near heat sources Do not install the device in environments where temperatures may reach 0 C For installation inside furniture consider that the maximum temperature of the device jacket is lower than 85 C and distances required for maintenance must be respected Gas connection The appliance was designed to use gases belonging to the categories as shown in the following table COUNTRY MODEL CATEGORIES NAZIONE MODELLO CATEGORIA FAST EVO ONT C 11 IT FAST EVO ONT C 14 112HM3 FAST EVO ONT C 16 Accertarsi tramite le targhette poste sull imballo e sull apparecchio che sia destina
48. ng 16 DHW specific flow rate 17 output efficiency 19 Gases which may be used 20 Temperature ambiante de fonctionnement 22 Max domestic hot water temperature Ariston Thermo SpA Viale A Merloni 45 60044 Fabriano AN www aristonthermo it info it aristonthermo com Servizio clienti 199 111 222 Costo della chiamata al telefono fisso 0 143 Euro al minuto in fascia oraria intera e 0 056 Euro in fascia oraraia ridotta IVA inclusa 420010535100
49. not be held responsible for any damage caused as a result The applaince is delivered in a carton Once you have removed all the packaging make sure the appliance is intact and that no parts are missing If this is not the case please contact your supplier Keep all packaging material clips plastic bags polystyrene foam etc out of reach of children as it may present a potential hazard In the event of a fault and or malfunction turn the appliance off turn off the gas cock disconnected from the electricity supply and do not attempt to repair it yourself Contact a qualified professional instead All repairs which should only be performed using original spare parts should be carried out by a qualified professional Failure to comply with the above instructions could compromise the safety of the appliance and invalidate all liability on the part of the manufacturer In the event of any maintenance or other structural work in the immediate vicinity of the ducts or flue gas exhaust devices and their accessories switch OFF the appliance disconnected from the electricity supply and shutting off the gas control valve When the work has been completed ask a qualified technician to check the efficiency of the ducting and the devices generalita overview Per la pulizia delle parti esterne spegnere l apparecchio e togliere l alimentazione elettrica Effettuare la pulizia con un panno umido imbevuto di acqua saponata
50. nzionamento dell apparecchio il luogo di installazione deve essere idoneo in relazione al valore della temperatura limite di funzionamento ed essere protetto in modo tale che l apparecchio non entri direttamente in contatto con gli agenti atmosferici L apparecchio progettato per l installazione a parete e deve essere installato su una parete idonea a sostenerne il peso Nella creazione di un vano tecnico si impone il rispetto di distanze minime che garantiscano l accessibilit alle parti interne dell apparecchio Before installing the appliance The appliance heats water to a temperature below boiling It should be connected to a a domestic water mains supply that must correspond in size to the performance and its power of the appliance Before connecting the appliance it is first necessary to perform the following operations Carefully wash the system piping in order to remove any screw thread or welding residues or any dirt which might prevent the appliances from operating correctly Make sure that the appliance is set up for operation with the type of gas available read the information on the packaging label and on the boiler data plate Make sure that there are no obstacles inside flue exhaust and that it does not contain any discharge from other appliances unless the flue is meant to serve more than one user in accordance with current legal requirements Where there is already a connection to existing flue
51. olli interni da parte della scheda a microprocessore che opera se necessario un blocco di sicurezza Spegnere l apparecchio chiudere il rubinetto del gas togliere l alimentazione elettrica e contattare un tecnico qualificato Gli errori sono segnalati tramite il display Appliance shut off conditions The appliance is protected from malfunctions by means of internal checks performed by the electronic P C B which stops the appliance from operating if necessary Switch off the appliance Shut off the gas valve disconnected it from the electricity supply and contact a qualified technician The display shows the error codes ARISTON A ATTENZIONE IL SENSORE FUMI NON DEVE MAI ESSERE MODIFICATO O MESSO FUORI SERVIZIO PER NON COMPROMETTERE IL BUON FUNZIONAMENTO DELL APPARECCHIO EVENTUALI CATTIVE CONDIZIONI DI TIRAGGIO POSSONO PROVOCARE IL RIFLUSSO DIGAS COMBUSTINELL AMBIENTE DI INSTALLAZIONE PERICOLO DI INTOSSICAZIONE DA MONOSSIDO DI CARBONIO A ATTENZIONE L acqua a temperatura superiore ai 50 C provoca gravi ustioni Verificare sempre la temperatura dell acqua prima di qualsiasi utilizzo A WARNING NEVER TAMPER WITH OR DECOMMISSION THE FLUE GAS SENSOR THIS COULD AFFECT THE PROPER OPERATION OF THE APPLIANCE POOR DRAUGHT CONDITIONS COULD CAUSE EXHAUST GAS BACKFLOW INTO THE INSTALLATION ROOM HAZARD OF CARBON INTOXICATION MONOXIDE A WARNING Wat
52. onnected from the electricity supply contactthe Technical Assistance Service or a qualified technician in order to repair the flue gas discharge fault once the cause of the malfunction is detected Whenever maintenance work is performed on the device use original spare parts only and follow the relative instructions carefully 31 manutenzione maintenance Istruzioni per l apertura della mantellatura ed ispezione dell interno Prima di qualunque intervento nell apparecchio chiudere il rubinetto del gas e togliere l alimentazione elettrica Per accedere all interno dell apparecchio necessario svitare le 3 viti L agganciare il mantello al telaio tramite i ganci E ATTENZIONE Scollegare il cavo di collegamento del display con la scheda principale Instructions for opening the casing and performing an internal inspection Before performing any work on the appliance disconnected it from the electricity supply and close the gas valve To access the inside of the appliance you need to Remove the three screws L Fitthe casing to the frame using the hooks E ATTENTION Disconnect the display cable to the main P C B 32 manutenzione maintenance La manutenzione essenziale per la sicurezza il buon funzionamento e la durata dell apparecchio Va effettuata in base a quanto previsto dalle norme vigenti Prima di iniziare le operazioni di manutenzione chiudere il ru
53. ostruttore non considerato responsabile Se l apparecchio installato all interno dell appartamento verificare che siano rispettate le disposizioni relative all entrata dell aria ed alla ventilazione del locale secondo le leggi vigenti Pannello di controllo WARNING Installation first ignition and maintenance work must be performed by qualified personnel only in accordance with the instructions provided Incorrect installation may harm individuals animals or property the manufacturer will not be held responsible for any damage caused as a result If the appliance is installed inside the apartment make sure that all provisions relating to the air inlet and room ventilation in compliance with current legislation are respected Control pannel 1 Tasto Reset 2 Display 3 Tasto regolazione temperatura acqua calda sanitaria 4 Tasto regolazione temperatura acqua calda sanitari 5 Tasto ON OFF ARISTON 1 Reset button 2 Display 3 Domestic hot water temperature adjustment button 4 Domestic hot water temperature adjustment button 5 ON OFF button manuale d uso user s manual Procedura di accensione verificare che il rubinetto sul raccordo dell acqua fredda sia aperto verificare che il rubinetto del gas sia aperto premere il tasto ON OFF il display si illumina L apparecchio pronto il funzionamento Aprire un rubinetto dell a
54. otando la manopola in posizione OFF chiudere il rubinetto del gas togliere l alimentazione elettrica svuotare l impianto sanitario se c pericolo di gelo In caso di disattivazione definitiva dell apparecchio far eseguire le operazioni da personale tecnico qualificato Per la pulizia delle parti esterne spegnere l apparecchio e togliere l alimentazione elettrica Non utilizzare o conservare sostanze facilmente infiammabili nel locale in cui installato l apparecchio This book user s and installation manual is an integral and essential component of the product Must be kept carefully by you and will always accompany the appliance in the event of its sale to another owner or user and or transfer to another installation Carefully read the instructions and warnings contained in this manual as it contain important information about safe installation operation and maintenance This appliance is designed to produce hot water for domestic use It should be connected to a distribution network for domestic hot water that must be compatible with its performance and power levels The use of the appliance for purposes other than those specified is strictly forbidden The manufacturer cannot be held responsible for any damage caused by improper incorrect and unreasonable use of the appliance or by the failure to comply with the instructions given in this manual Installation maintenance and all other interventions must be
55. play will show the error code see table below To restore the system switch ON OFF the device Error code table Error code Eg E X Switch OFF the appliance close the gas valve and disconnected from the electricity E d Contact a qualified technician ES If the appliance won t start again or stops repeatedly once you ve carried out the relevant checks press the ON OFF button close the gas valve disconnected it from the electricity and contact a qualified technician Description Checks to make SHOULD THE ERROR NOT BE ELIMINATED DO NOT ACTIVATE THE APPLIANCE A WARNING NEVER TAMPER WITH OR DECOMMISSION THE FLUE GAS SENSOR THIS COULD AFFECT THE PROPER OPERATION OF THE APPLIANCE POOR DRAUGHT CONDITIONS COULD CAUSE EXHAUST GAS BACKFLOW INTO THE INSTALLATION ROOM HAZARD OF CARBON INTOXICATION MONOXIDE manuale d uso user s manual Arresto Temporaneo per anomalia evacuazione fumi Tale controllo blocca l apparecchio in caso di anomalia di evacuazione fumi Il blocco temporaneo Dopo 12 minuti l apparecchio inizia la procedura di accensione se le condizioni sono ritornate alla normalit prosegue nel funzionamento in caso contrario l apparecchio si blocca ATTENZIONE n caso di malfunzionamento o di interventi ripetuti necessario spegnere l apparecchio chiudere il rubinetto del gas togliere l alimentazione elettr
56. prevent falls The space where any accidental fall may occur should be free from dangerous obstacles and any impact upon falling should be cushioned by semi rigid or deformable surfaces A Personal injury caused by falling from a height Make sure the workplace has suitable hygiene and sanitary conditions in terms of lighting ventilation and solidity of the structures A Personal injury caused by knocks stumbling etc Protect the appliance and all areas in the vicinity of the work place using suitable material A Damage to the appliance or surrounding objects caused by falling splinters knocks and incisions Handle the appliance with suitable protection and with care A Damage to the appliance or surrounding objects from shocks knocks incisions and squashing During all work procedures wear individual protective clothing and equipment Personal injury caused by electrocution falling splinters A or fragments inhalation of dust shocks cuts puncture wounds abrasions noise and vibration Place all debris and equipment in such a way as to make movement easy and safe avoiding the formation of any piles which could yield or collapse A Damage to the appliance or surrounding objects from shocks knocks incisions and squashing All operations inside the appliance must be performed with the necessary caution in order to avoid abrupt contact with sharp parts A Personal injury caused by cuts puncture wounds and ab
57. r technical assistance Information for the user Inform the user on how to operate the appliance In particular provide the user with the instruction manuals and inform him her that these must be stored with the appliance Moreover make sure the user is aware of the following How to set the temperature and adjustment devices for using the appliance correctly and in a more cost efficient way The system must be serviced regularly in compliance with legislation The settings relating to the supply of combustion air and combustion gas must not in any event be modified 34 Targhetta caratteristichei Symbols used on the data plate OMNOARWN gt Marchio Produttore Modello Nr di serie Codice commerciale Nr di omologa Paesi di destinazione categoria gas Predisposizione Gas Tipologia di installazione Dati elettrici Pressione massima sanitario Tipo apparecchio Portata termica max min Potenza termica max min Portata specifica Taratura potenza apparecchio Gas utilizzabili Temperatura ambiente minima di funzionamento Temperatura massima sanitario Legend Brand Manufacturer IGWH model Serial number Commercial reference Certification number Destination country Gas category Gas setting Installation type Electrical data 10 Maximum domestic hot water pressure 14 Input rating nominal heating 15 Power ouput heati
58. rasions Reset all the safety and control functions affected by any work performed on the appliance and make sure they operate correctly before restarting the appliance A Explosions fires or asphyxiation caused by gas leaks or an incorrect flue gas exhaust A Damage or shutdown of the appliance caused by out of control operation Before handling empty all components that may contain hot water carrying out any bleeding if necessary A Personal injury caused by burns Descale the components in accordance with the instructions provided on the safety data sheet of the product used airing the room wearing protective clothing avoid mixing different products and protect the appliance and surrounding objects A Personal injury caused by acidic substances coming into contact with skin or eyes inhaling or swallowing harmful chemical agents A Damage to the appliance or surrounding objects due to corrosion caused by acidic substances If you detect a smell of burning or smoke keep clear of the appliance disconnect it from the electricity supply open all windows and contact the technician Personal injury caused by burns smoke inhalation A asphyxiation 14 descrizione del prodotto product description Vista complessiva Schema idraulico Overall view Water circuit diagram Leg
59. re abrasioni Ripristinare tutte le funzioni di sicurezza e controllo interessate da un intervento sull apparecchio ed accertarne la funzionalit prima della rimessa in servizio A Esplosioni incendi o intossicazioni per perdita gas o per incorretto scarico fumi A Danneggiamento blocco dell apparecchio funzionamento fuori controllo Svuotare i componenti che potrebbero contenere acqua calda attivando eventuali sfiati prima della loro manipolazione A Lesioni personali per ustioni Effettuare la disincrostazione da calcare di componenti attenendosi a quanto specificato nella scheda di sicurezza del prodotto usato aerando l ambiente indossando indumenti protettivi evitando miscelazioni di prodotti diversi proteggendo l apparecchio e gli oggetti circostanti A Lesioni personali per contatto di pelle o occhi con sostanze acide inalazione o ingestione di agenti chimici nocivi A Danneggiamento dell apparecchio o di oggetti circostanti per corrosione da sostanze acide Nel caso si avverta odore di bruciato o si veda del fumo fuoriuscire dall apparecchio togliere l alimentazione elettrica aprire le finestre ed avvisare il tecnico Lesioni personali per ustioni inalazione fumi A intossicazione During all work carried out at a certain height generally with a difference in height of more than two metres make sure that parapets are used to surround the work area or that individual harnesses are used to
60. recchio L apparecchio protetto da malfunzionamento tramite controlli interni da parte della scheda elettronica In caso di blocco il display visualizza il codice dell errore vedi tabella sotto riportata Per ripristinare il sistema necessario effettuare un ON OFF dell apparecchio Tabella errori Controlli da effettuare Codice errore Descrizione Ec E3 Spegnere l apparecchio premendo il tasto ON OFF chiudere il rubinetto del gas E Ly togliere l alimentazione elettrica e contattare un tecnico qualificato Se effettuate le verifiche l apparecchio non riparte o si blocca ripetutamente ncessario spegnere l apparecchio premendo il tasto ON OFF chiudere il rubinetto del gas togliere l alimentazione elettrica e contattare un tecnico qualificato NON RIMETTERE IN FUNZIONE L APPARECCHIO SE L ERRORE NON E STATO ELIMINATO A ATTENZIONE IL SENSORE FUMI NON DEVE MAI ESSERE MODIFICATO O MESSO FUORI SERVIZIO PER NON COMPROMETTERE IL BUON FUNZIONAMENTO APPARECCHIO EVENTUALI CATTIVE CONDIZIONI DI TIRAGGIO POSSONO PROVOCARE IL RIFLUSSO DIGAS COMBUSTINELL AMBIENTE DI INSTALLAZIONE PERICOLO DI INTOSSICAZIONE DA MONOSSIDO DI CARBONIO Appliance shut off conditions The appliance is protected from malfunctions by means of internal checks performed by the electronic P C B which stops the appliance from operating if necessary In the event of lockout the dis
61. riodica dell impianto Non modificare in nessun caso le impostazioni relative all alimentazione di aria di combustione e del gas di combustione Operational test After having carried out the maintenance operations fill the appliance and the water circuit Begin operating the boiler Check the settings and make sure all the command adjustment and monitoring parts are working correctly Check the seal and that the system for the expulsion of fumes suction of comburent air is operating correctly Draining procedures The system must be drained using the following procedure Disconnected from the electricity supply Shut off the water mains inlet valve Open the hot and cold water taps WARNING Before handling empty all components which may contain hot water performing bleeding where necessary Descale the components in accordance with the instructions provided on the safety data leaflet supplied with the product used make sure the room is well ventilated wear protective clothing avoid mixing different products and protect the appliance and surrounding objects Seal all openings used to take a gas pressure reading or to make any gas adjustments Make sure that the nozzle is compatible with the supplied gas If a smell of burning is detected or smoke is seen leaking from the appliance or there is a smell of gas disconnected from the electricity supply shut off the gas valve open the windows and call fo
62. sanitaria 1 2 Ingresso Gas 1 2 Entrata fredda 1 2 Filtro entrata acqua fredda 9008 L apparecchio provvisto di un filtro G sull ingresso dell acqua fredda In caso di sporcizia nell impianto idrico provvedere periodicamente alla pulizia dello stesso IMPORTANTE Non mettere in funzione l apparecchio senza il filtro IMPORTANTE Se lapparecchio viene installato in zone con presenza di acqua dura gt 200 mg l necessario installare un addolcitore per limitare la precipitazione di calcare nello scambiatore La garanzia non copre i danni causati dal calcare 14 16L i i Hot water outler 1 2 Ingresso Gas 1 2 Cold water inlet1 2 Cold water inlet filter The device is equipped with a filter located on the cold water entrance Periodically clean the hydraulic system if dirt is present IMPORTANT Do not activate the device without the filter IMPORTANT If the unit is installed in areas with the presence of hard water gt 200 mg 1 is necessary to install a water softener to reduce the precipitation of limestone in the heat exchanger The warranty does not cover damage caused by the limestone 20 installazione installazione Collegamento impianto solare In caso di collegamento dell apparecchio con una installazione solare necessario verificare che l acqua in ingresso non superi i 60 C In caso contrario provvedere all installa
63. sponsabile per eventuali danni causati dalla mancanza di messa a terra dell impianto o per anomalie di alimentazione elettrica In caso di sostituzione del cavo elettrico di alimentazione rivolgersi a personale qualificato utilizzare esclusivamente ricambi originali first disconnect it from the electrical power supply Electrical connections For increased safety ask a qualified technician to perform a thorough check of the electrical system The manufacturer is not responsible for any damage caused by the lack of a suitable earthing system or by the malfunctioning of the electricity mains supply In the event that the power supply cable must be changed replace it using original spare parts 22 installazione installazione Schema elettrico Electrical diagram 1 54 98 9 m 5 giallo yellow arancione orange marrone brown rosso red rosso red black nero arancione orange 9 410 verde green bianco white nero black arancione orange verde green aranci ne orange rosso red nero black
64. t s necessary check the gas adjustments when you start the appliance for the first time Electricity supply Check that the voltage and frequency of the electricity supply correspond to the data shown on the boiler data plate Make sure that the earthing connection is efficient Connect the cable to the appliance see fig Riempimento circuito idraulico Procedere nel modo seguente aprire gradualmente il rubinetto posto sull entrata fredda aprire un rubinetto dell acqua calda sanitaria A ATTENZIONE L APPARECCHIO PU ESSERE UTILIZZATO SOLO CON PRESENZA DI ACQUA NELLO SCAMBIATORE Alimentazione Gas Procedere nel modo seguente verificare che il tipo di gas erogato corrisponda a quello indicato sulla targhetta dell apparecchio aprire porte e finestre evitare la presenza di scintille e fiamme libere verificare la tenuta dell impianto del combustibile con rubinetto di intercettazione chiuso e successivamente aperto con valvola del gas chiusa disattivata per 10 minuti il contatore non deve indicare alcun passaggio di gas Filling the hydraulic circuit Proceed in the following manner Gradually open the valve located on the cold inlet open a D H W tap A WARNING DO NOT USE THE APPLIANCE WITHOUT WATER Gas supply Proceed in the following manner Make sure that the main gas supply uses the same type of gas as indicated on the appliance data plate Open
65. tilizzazione per scopi diversi da quanto specificato Il costruttore non considerato responsabile per eventuali danni derivanti da usi impropri erronei ed irragionevoli o da un mancato rispetto delle istruzioni riportate sul presente libretto Iltecnicoinstallatore deve essere abilitatoall installazione degli apparecchi per il riscaldamento secondo la Legge n 46 del 05 03 1990 ed a fine lavoro deve rilasciare al committente la dichiarazione di conformit L installazione la manutenzione e qualsiasi altro intervento devono essere effettuate nel rispetto delle norme vigenti e delle indicazioni fornite dal costruttore In caso di guasto e o cattivo funzionamento spegnere l apparecchio chiudere il rubinetto del gas togliere l alimentazione elettrica e non tentare di ripararlo ma rivolgersi a personale qualificato Eventuali riparazioni effettuate utilizzando esclusivamente ricambi originali devono essere eseguite solamente da tecnici qualificati Il mancato rispetto di quanto sopra pu compromettere la sicurezza dell apparecchio e fa decadere ogni responsabilit del costruttore Nel caso di lavori o manutenzioni di strutture poste nelle vicinanze dei condotti o dei dispositivi di scarico dei fumi e loro accessori spegnere l apparecchio e a lavori ultimati far verificare l efficienza dei condotti o dei dispositivi da personale tecnico qualificato In caso di inutilizzo prolungato dell apparecchio necessario spegnere l apparecchio ru
66. to al paese in cui dovr essere installato che la categoria gas per la quale l apparecchio stato progettato corrisponda ad una delle categorie ammesse dal paese di destinazione La tubazione di adduzione del gas deve essere realizzata e dimensionata secondo quanto prescritto dalle Norme specifiche ed in base alla potenza massima dell apparecchio assicurarsi anche del corretto dimensionamento ed allacciamento del rubinetto di intercettazione Prima dell installazione si consiglia un accurata pulizia delle tubazioni del gas per rimuovere eventuali residui che potrebbero compromettere il funzionamento dell apparecchio E necessario verificare che il gas distribuito corrisponda a quello per cui stato predisposto l apparecchio vedi targa dati E inoltre importante verificare la pressione del gas metano o GPL che si andr ad utilizzare per l aliImentazione dell apparecchio in quanto se insufficiente ridurre la potenza del generatore con disagi per l utente FAST EVO ONT C 11 FAST EVO ONT C 14 FAST EVO ONT C 16 Make sure using the labels on the packaging and the data plate on the appliance itself that the appliance is in the correct country and that the gas category for which the appliance was designed corresponds to one of the categories available in the country where it will be used The gas supply piping must be created and measured out in compliance with specific legal requirements and in accordance
67. to responsabile per eventuali danni derivanti da usi impropri erronei ed irragionevoli o da un mancato rispetto delle istruzioni riportate sul presente libretto L installazione la manutenzione e qualsiasi altro intervento devono essere effettuate nel rispetto delle norme vigenti e delle indicazioni fornite dal costruttore Un errata installazione pu causare danni a persone animali e cose per i quali l azienda costruttrice non responsabile L apparecchio viene fornito in un imballo di cartone dopo aver tolto l imballo assicurarsi dell integrit e della completezza della fornitura In caso di non rispondenza rivolgersi al fornitore Gli elementi di imballaggio graffe sacchetti in plastica polistirolo espanso ecc non devono essere lasciati alla portata dei bambini in quanto fonti di pericolo In caso di guasto e o cattivo funzionamento spegnere l apparecchio chiudere il rubinetto del gas togliere l alimentazione elettrica e non tentare di ripararlo ma rivolgersi a personale qualificato Prima di ogni intervento di manutenzione riparazione nell apparecchio necessario ruotare la manopola in posizione OFF chiudere il rubinetto del gas togliere l alimentazione elettrica Eventuali riparazioni effettuate utilizzando esclusivamente ricambi originali devono essere eseguite solamente da tecnici qualificati Il mancato rispetto di quanto sopra pu compromettere la sicurezza dell apparecchio e fa decadere ogni r
68. with the maximum power of the appliance you should also make sure that the shut off valve is the right size and that it is connected correctly Before carrying out the installation it is recommended that the fuel pipes are cleaned thoroughly in order to remove any residues which could prevent the appliance from operating correctly Check that the supplied gas corresponds to the type of gas for which the appliance was designed see the data plate located on the appliance itself It is also important to check that the pressure of the gas methane or LPG you will be using to feed the appliance is suitable because if it is insufficient the power of the generator may be reduced causing inconvenience for the user installazione installazione Collegamento idraulico In figura sono rappresentati i raccordi per l allacciamento idraulico e gas Verificare che la pressione massima della rete idrica non superi i 10 bar in caso contrario necessario installare un riduttore di pressione Verificare che la pressione minima non sia inferiore a 0 2 mbar Vista raccordi idraulici Water connection The illustration shows the connections for the water and gas attachments of the appliance Check that the maximum water mains pressure does not exceed 10 bar if it does a pressure reducing valve must be installed Ensure that the minimum pressure is not lower than 0 2 bar View of the hydraulic Connections Uscita acqua calda
69. ximum burner pressure 27 Checking the minimum burner pressure 28 Checking slow ignition power 28 Gas settins table rnn rrnnrresreerte ne 29 Gas uode te ce rct t cede 29 Appliance protection devices 30 Table summarising error codes 31 Maintenance nee eee erre rerretrrrssrr rere rent 32 Instruction for opening the casing and performing an internal inspection sess 32 General comments ren nrtesrrertn rnnr 33 Operational test tte ict ne Reda 34 Draining procedures i 34 Information for the user idea 34 Symbols used on the data plate 35 generalita overview Avvertenze per l installatore L installazione e la prima accensione dell apparecchio devono essere effettuate da personale qualificato in conformit alle normative nazionali di installazione in vigore e ad eventuali prescrizioni delle autorit locali e di enti preposti alla salute pubblica Questo apparecchio serve a produrre acqua calda per uso domestico Deve essere allacciato a una rete di distribuzione di acqua calda sanitaria compatibilmente alle sue prestazioni ed alla sua potenza vietata l utilizzazione per scopi diversi da quanto specificato Il costruttore non considera
70. zione di una valvola miscelatrice termostatica Connecting to solar installation When connecting the unit with a solar installation is necessary to verify that incoming water does not exceed 60 C If it does not provide for the installation of a thermostatic mixing valve Uscita acqua calda Entrata acqua fredda Valvola deviatrice miscelatrice termostatica D gt om B Hot water outler D Cold water inlet V Diver mixing valve termostatic Collegamento condotti scarico fumi L installazione dei condotti di scarico fumi deve essere effettuata in conformit alle normative vigenti ed alle istruzioni fornite dal costruttore Nel caso di installazione di tipo B il locale in cui l apparecchio viene installato deve essere ventilato da una adeguata presa d aria conforme alle norme vigenti Nell installazione di un sistema di scarico fare attenzione alle tenute per evitare infiltrazioni di fumi nel circuito aria Connection of flue gas discharge ducts The appliance must be connected to a flue gas discharge system that complies with the regulation in force and instructions provided by the manufacturer When type B installation is used the room in which the appliance is installed must be ventilated using a suitable air inlet which complies with current legislation When installing an exhaust system take care of the seals to prevent any flue gas leaking into the air circuit N ATTENZIONE IN WARNING