1. RTI TYPE WITHOUT NEUTRAL T MODELS 10 TECHNICAL SPECIFICATION RTC Input rated voltage 400V 15 N Output voltage 400V N Output voltage accuracy 1 Frequency 50 60Hz Regulation speed 20 1000 sec Volt Load acceptable power factor any da 0 a 100 less than 1 Acceptable load variation Harmonic distortion Surge suppression Attenuation RTC 220 220V 15 220V 1 50 60Hz 20 1000 sec Volt any da 0 a 100 less than 1 Tolerable load unbalance qualsiasi qualsiasi Full load efficiency 94 98 94 98 Ambient temperature 10 C 40 C 10 C 40 C according to different ratings and voltages rated power part no weight part no weight 6KVA RTCO6K 85 RTCO6K 220 90 9KVA RTCO9K 88 RTCO9K 220 95 12KVA RTC12K 94 RTC12K 220 120 15KVA RTC15K 96 RTC15K 220 135 22KVA RTC22K 120 RTC22K 220 190 30KVA RTC30K 126 RTC30K 220 250 Standard accessories 3 4 poles automatic circuit breaker digital a c voltmeter in out voltmeter display switch phase to N and phase to phase voltage display switch fine output regulation screws on each phase In out connectors Input three phase isolation transformer RTI range only 11 I N CASE OF ASSI STANCE In order to improve our service we trust in customers full co operation We would like to remind you some data to report herein before calling our technical service A Model Part No unnnai ian B work number C purchased by D computer or load
2. di tu supplisce infine alla mancanza del neutro in entrata indispensabile per il funzionamento di uno stabilizzatore della serie RT Per ultimo nelle zone dotate solo di tensione 230V trifase senza neutro permette di ottenere una tensione a 400V trifase stabilizzata con neutro accessibile Gli stabilizzatori della serie RTI sono dotati di un interruttore automatico quadripolare tre voltmetri digitali in grado di fornire il valore della tensione in entrata ed in uscita di una morsettiera per il collegamento alla rete ed al carico che facilit notevolmente l installazione 2 PRINCIPIO DI FUNZIONAMENTO tte le apparecchiature a valle dello stabilizzatore la possibilit di collegare a terra il neutro in uscita Le serie RTC RTI utilizzano per la regolazione di ogni fase il principio del trasformatore serie Un variatore regolato tramite un circuito di comando in base alla tensione di uscita risultante alimenta un trasformatore il cui secondario posto in serie sulla fase La tensione che scaturisce dal secondario del trasformatore va a sommarsi o a sottrarsi alla tensione di ingresso La lettura continua della tensione di uscita permette al circuito di comando di fornire un impulso di rotazione al motore in c c che regola la tensione di uscita del variatore Ogni modulo di fase collegato agli altri due con una configurazione circuitale a stella che comporta l utilizzo del neutro in ingresso e la disponibilit dello stesso s
3. of the RT range with the advantages provided by an isolation transformer The indisputable advantages of such a system are evident total separation of the mains with elimination or attenuation of mains disturbances and protection of all equipment protected by the line conditioner The possibility to connect the output neutral to earth compensates the absence of input neutral indispensable for the functioning of RT stabilisers Finally in areas provided with only 220V three phase supply without neutral upon request RTI provides a 400V 380V regulated power supply with accessible neutral RTI line conditioners are equipped with automatic 4 pole circuit breaker three digital voltmeters with input and output voltage reading fine voltage regulation for each phase 2 Working principle RTC RTI stabilisers are manufactured according to the principle of the buck boost transformer A control circuit regulates through a DC motor the output voltage of a variable transformer which supplies a buck boost transformer whose secondary winding is connected in series to the line voltage The output voltage of the transformer increases or decreases the line voltage The continuous reading of the output voltage allows the control circuit to give a rotation command to the DC motor which regulates the variable transformer Each phase module is connected to the following with a star three phase configuration circuit as shown on scheme No 1 R
4. AI NTENANCE 1 The stabiliser must not operate in dusty areas 2 Never clean the surface of the equipment with strong claning products do not use oil 3 Never use the automatic circuit breaker as a main circuit breaker On the long term this may damage the stabiliser 4 Some models are fitted with cooling fans Do not cover the fans Do not place anything on the cover of the stabiliser do not place it close to any heating source 5 If these rules are respected the stabiliser will not require maintenance interventions for many years of operation It is useful to chack regularly input and output voltage to prevent any damage to your equipmaent in case of a failure of the stabiliser 8 CLEANI NG OF THE VARI ABLE TRANSFORMERS Every 30 36 months a cleaning of the variable transformers could be necessary Turn off the stabiliser Open the front door of the stabiliser Rotate the brush to an end manually Carefully clean the surface with abrasive paper until graphite and dust are removed Rotate the brush on reverse to the second end and clean the part previously covered by the brush Verify rotating the brush that the surface is clean and flat ai 6 k factor srl 6 Repat the same on all the variable transformers 9 GENERAL SCHEME RI TS SI TS Wout TI TS RTC RTI TYPE WITH NEUTRAL RTC
5. C22K Max power available 22 000VA Load 1 Three phase 400Va c 10KVA 10 000VA Residual power 12 000VA Available power on each phase R S or T 12 000VA 3 4 000VA Connect the feeding line of the load s to the terminals marked OUTPUT respecting the succession of the three phases R S T and neutral N Close the fron door and turn on the circuit breaker always with loads OFF After the stabiliser is on turn the loads on check that the power requested by the loads is lower than the rated power of the stabiliser For this operation use an A meter to meausre the current on each phase The current on each phase must not exceed one third of the rated current of the stabiliser The voltmeter shows for each phase the input or the output voltage according to the position of the below switch IN or OUT and the R S T phase switch The OUT CONTROL screws allow to obtain a fine regulation of the voltage of each phase For each phase verify that the input voltage is in the acceptable range Input voltage can be displaied using the IN OUT switch and the R S T phase switch Remember that the Voltmeter shows the phase voltage between phase and neutral it means that for a rated voltage of 400Va c three phase the voltage will display 230V for each phase approx 400 1 73 The standard acceptable input range is 15 of the rated voltage If the voltage is 400V acceptable range is for each phase from 195V up to 264V When th
6. K 220 250 RTI30K 216 Dotazione interruttore automatico quadripolare voltmetro digitale commutatore per l indicazione in out del voltmetro commutatore per la lettura della tensione su ogni fase e della tensione concatenata regolazione fine della tensione per ogni fase morsettiere per il collegamento alla rete e al carico trasformatore d isolamento solo per la serie RTI 11 INCASODI ASSISTENZA La ditta confida in una completa collaborazione della Clientela al fine di migliorare il proprio servizio Pertanto ricordiamo alcuni dati da riconoscere prima di interpellare il ns servizio tecnico a Modello della macchina b Numero di matricola i c Acquistato da d Tipo di carico e Assorbimento inserito rilevabile sulle targhe di caratteristiche degli apparecchi TS DMECLOMISCOMEMALO i i ia In caso di restituzione per riparazione allegare sempre alla macchina una lettera citando i dati richiesti insieme all imballo originale ed in PORTO FRANCO k factor srl Index General data Working principle Technical specification Controls and signals Instructions for the installation Rules for RTC delta 230V Rules for a proper use maintenance Cleaning of the variable transformers General scheme 10 Technical data 11 Incase of assistance CONQUAWNE 1 General data The RTC series electromechanical stabilisers with electronic control with independent output voltage regulation for
7. K FACTOR SRL Stabilizzatori di tensione trifase elettromeccanici Serie RTC RTC 220 RTI Istruzioni per l uso e la manutenzione Three phase electromechanical voltage stabiliser RTC RTC 220 RTI range Directions for use and maintenance Nota Questo manuale si riferisce al modello per tensione di rete 400V N Per altri paesi con le medesime caratteristiche gli stabilizzatori sono fornibili con tensione di rete 380V o 415V o altre a richiesta Controllate che la tensione nominale dell apparecchio corrisponda a quella del paese dove viene installato Warning this handbook refers to the model for network voltage of 400V N For other countries under the same characteristic stabilisers are supplied with rated voltage 380V or 415V Check that the rated voltage on the plate of the apparatus is conforming to the country network one and to the installation of the stabiliser RTC RTC RTC RTC RTI k factor srl INDI CE 1 Generalit 2 3 4 5 6 7 8 9 10 Dati tecnici Principio di funzionamento Caratteristiche elettriche Comandi e strumentazione Istruzioni per l installazione Norme particolari per serie RT triangolo 230V Norme per un corretto utilizzo Manutenzione Intervento di pulizia dei variatori Schema di principio 11 Incaso di assistenza 1 GENERALIT Gli stabilizzatori trifase elettromeccanici della serie RTC sono del tipo elettromeccanico a c
8. TI range has also a three phase isolation transformer 3 Technical specification Output voltage is constant within a 1 on the rated voltage in the following conditions Input voltage between 340 460V three phase Frequency 50 60 Hz Load between 0 100 Any load unbalancce When the input voltage changes a regulation impulse move the brush of the variable transformer which through the buck boost transformer increases or decreases the line voltage of the correct value Regulation speed is approximately 20 1000 Sec Volt RTC RTI stabilisers allow any variation of the power factor Efficiency is approx 94 98 The stabiliser is protected by an automatic circuit breaker 4 Controls and signals On the front up panel the following controls signals are available 2 i Digital voltmeter In Out voltage reading switch Phase reading switch Fine voltage regulation for each phase Automatic circuit breaker Mains lamp 5 Instruction for installation Open the front door checking the switch is off On the right side two cable glands are provided for input and output cables for RTG range access is allowed from the sides through the base or from the bottom side Insert the input cable in a cable gland k factor srl The stabiliser is provided with a terminal board consisting in a four terminals marked R S T N for input b four terminals marked R S T N for output c one or two earth terminals Connect the line v
9. ai morsetti denominati ingresso Anche in questo caso non presente in ingresso il morsetto N neutro Attenzione non intervenire mai sui morsetti di collegamento del trasformatore di isolamento collegamenti relativi al trasformatore sono gi effettuati e non devono essere modificati morsetti utilizzati non devono essere utilizzati per i collegamenti in entrata o uscita Dopo avere inserito il cavo di alimentazione del carico nel secondo passacavo collegare le fasi ai morsetti denominati uscita rispettando la successione delle tre fasi R S T e neutro N Collegare la terra in ingresso e uscita ai morsetti di terra dell apparecchio SE SONO COLLEGATI CARI CHI MONOFASE E SEMPRE CONVENI ENTE DI STRI BUI RLI EQUAMENTE SULLE TRE FASI AD OGNI FASE R S T POSSONO ESSERE COLLEGATI CARICHI MONOFASE NEI LIMITI DI UN TERZO DELLA POTENZA RESI DUA UNA VOLTA COLLEGATE LE UTENZE TRI FASE Es Stabilizzatore trifase RT22K 22KVA Potenza massima disponibile 22 000VA Utenza 1 Trifase 400V 10KVA 10 000VA Potenza residua 12 000VA Disponibili su ogni fase R So T 12 000VA 3 4 000VA Bloccare i cavi di ingresso uscita con i pressacavi Richiudete il portello frontale e sollevate l interruttore magnetotermico L accensione dello stabilizzatore deve sempre avvenire con le utenze spente Accendete il carico e verificate tramite una pinza amperometrica che la potenza assorbita sia inferiore alla potenza di targa dello sta
10. bilizzatore Effettuando una misura per ogni fase la potenza assorbita non deve superare un terzo della potenza di targa dello stabilizzatore Un eventuale squilibrio del carico anche del 100 perfettamente tollerato dallo stabilizzatore purch la potenza assorbita su ogni fase non superi un terzo della potenza di targa Verificate per ogni fase agendo sui commutatore voltmetrico IN OUT e sul commutatore di fase posti sul pannello frontale che la tensione d ingresso sia entro i limiti di targa dell apparecchio Ricordate che il voltmetro indica la tensione di fase prelevata tra fase e neutro in altre parole la tensione di targa diviso 1 73 Se la tensione trifase 400V i voltmetri indicheranno in ingresso e uscita una tensione nominale di 230V Quando il commutatore posto in posizione IN il voltmetro indica la tensione di ingresso Tale tensione non deve superare i limiti 15 15 della tensione nominale Nel caso di tensione trifase 400V i limiti sono da 195V a 264V Quando il commutatore in posizione OUT il voltmetro indica la tensione di uscita Tale tensione non deve eccedere l errore del 1 non deve variare quindi oltre le tensioni 228 232V Lo stabilizzatore RT RTI dotato di tre viti di regolazione OUT CONTROL che consente di effettuare la taratura precisa dell apparecchio per ogni fase Tale taratura deve essere effettuata soltanto la prima volta dopodich resta fissa fino ad una nuova regolazione Si pu decidere di p
11. cchio 4 Alcuni modelli sono dotati di ventole di raffreddamento Prestate attenzione a non coprire tali ventole per evitare l eccessivo riscaldamento dell apparecchio Non appoggiare oggetti libri o altro sul coperchio dello stabilizzatore evitando inoltre di collocarlo vicino a fonti di calore 5 Se vengono rispettate con cura le norme precedenti lo stabilizzatore non richieder interventi di manutenzione per diversi anni E bene saltuariamente verificare che su ogni fase la tensione venga regolata correttamente controllando le tensioni in entrata e uscita 8 INTERVENTO DI PULIZIA DEI VARI ATORI Pu essere necessario con una periodicit di 30 36 mesi effettuare una pulizia dei variatori Per effettuare tale operazione seguire le seguenti indicazioni 1 Scollegare lo stabilizzatore dalla rete k factor srl 2 Svitare le viti dei tre pannelli frontali di fase e staccare il connettore degli strumenti 3 Portare lentamente a fine corsa il braccetto con la spazzola del variatore spostandolo con la mano 4 Utilizzando carta vetrata molto fine pulire la superficie di contatto con la spazzola fino a quando la grafite e la polvere depositate non siano eliminate 5 Spostare leggermente il braccetto delle spazzole per pulire anche nel punto di fine corsa Verificare ruotando lentamente il braccetto con la mano che il percorso della spazzola sia regolare e privo di asperit 6 Effettuare la stessa operazione per le altre fasi e rich
12. e swith is in OUT position the voltmeter shows the output voltage The output voltage must nox exceed the limit of 1 of the rated voltage please also consider that each voltmeter can measure with a tolerance of 0 5 1 digit The voltage must not exceed the renge between 228V and 232V in the 400V models RTC and RTI stabilisers are provided with three fine voltage regulation screw which allow an acurate regulation of the output voltage This regulation is normally made by the factory but it can be done also by the user if any factor changes this regulation It is advisable to do this regulation only at the first use User cna decide to regulate the stabilised voltage to a voltage different from the rated one Through the regulation screws it is possible to regulate the output stabilised voltage up to a 5 of the rated voltage Please note that regulating the output voltage to a lower level output total power decreases proportionally Now the stabiliser is ready for the use 6 RULES FOR RTC DELTA 230V OR 220V T MODELS If you purchased a three phase stabilisers in Delta T configuration for networks without the neutral please remember that In Out connectors do not have a Neutral connector Neutral is not provided and is not necessary for the use of the stabiliser Il In Out voltmeters will read the Phase to phase voltage In the case of the 230V rated voltage the voltmeter will read 230V 7 RULES FOR A PROPER USE M
13. each phase are an essential feature for highly unbalanced loads The stabilsers use three control circuits and three servo motors so that each individual phase may be stabilised independently from the others This special feature together with a high degree of reliability make the RTC series ideal for use in any applications requiring that the voltage is maintained rigorously constant near the rated value RTC stabilisers are mounted on a moveable rack they are exceptionally quiet runninng totally free from magnetic leakage and do not introduce harmonic distorsion All models are equipped with an anti disturbance device to attenuate line noise and voltage peaks For correct connections the neutral should always be accessible and the output connection must always be in star configuration If the stabiliser is used in combination with an input transformer the input connection may be made in either star or delta configuration also without the neutral On request a stabiliser is available with three phase 230V input and output without the necessity to provide a neutral at the stabiliser input RTC stabilisers are equipped with an automatic 4 pole switch three digital voltmeters for input and output voltage readings and terminal strip for connection to the mains and the load which significantly simplifies installation On request all models are available with insulation transformer The stabilisers of the RTI range combine the performance characteristic
14. if the equipment is returned F O T our factory No technical intervention may be claimed for any reason at the place of installation under guarantee Cut and send to our address for the validity of the guarantee _____ Tagliare e inviare in busta chiusa per la validit della garanzia Model type Modello Work no No Matricola Manuf Year Anno fabbricazione Tested by Firma collaudo Data di acquisto Purchase date _______ _ Nome e indirizzo dell acquirente NMame and address of the owner Inviare entro 15 gg dalla data di acquisto to be sent within 15 days from the purchase date
15. iudere l apparecchio 9 SCHEMA DI PRINCIPIO RI D E ll SI uw ni I z 4 l Ww Wout TI BE a l Modelli RTC RTI con neutro Modelli RTC senza neutro serie RTC 220 10 DATI TECNICI serie RTC serie RTC 220 serie RTI Tensione nominale entrata 400V 15 N 220V 15 400V 15 Tensione di uscita 400V N 220V 400V N Precisione della tensione di uscita 1 1 1 Frequenza 50 60Hz 50 60Hz 50 60Hz Tempo di risposta 20 millisec per Volt 20 millisec per Volt 20 millisec per Volt Fattore di potenza del carico qualsiasi qualsiasi qualsiasi Variazione accettabile del carico da 0 a 100 da 0 a 100 da 0 a 100 Distorsione armonica introdotta inferiore all 1 inferiore all 1 inferiore all 1 Soppressione picchi di tensione fino a 6kV a 100 Attenuazione disturbi gt 40 dB Squilibrio ammesso dal carico qualsiasi qualsiasi qualsiasi Rendimento a pieno carico 94 98 94 98 94 98 Temperatura 10 C 40 C 10 C 40 C 10 C 40 C a seconda delle potenze Potenza nom Codice ord Peso Kg Codice ord Peso Kg Codice ord Peso Kg 6KVA RTCO6K 85 RTCO6K 220 90 RTIO6K 102 9KVA RTCO9K 88 RTCO9K 220 95 RTIO9K 116 12KVA RTC12K 94 RTC12K 220 120 RTI12K 134 15KVA RTC15K 96 RTC15K 220 135 RTI15K 156 22KVA RTC22K 120 RTC22K 220 190 RTI22K 198 30KVA RTC30K 126 RTC30
16. k factor srl 5 ISTRUZIONI PER L I NSTALLAZI ONE Aprire il portello frontale utilizzando la chiave fornita assicurandosi che l interruttore sia abbassato Sul lato destro sono posti due pressacavi per il passaggio dei cavi di entrata e uscita per la serie RTI l ingresso cavi dal basso o dai lati aprendo i lati dello zoccolo Inserire il cavo di entrata in un pressacavo Lo stabilizzatore provvisto di una morsettiera di collegamento cos composta nr 4 morsetti denominati R S T N per ingresso nr 4 morsetti denominati R S T N per uscita nr 1 o 2 morsetti di terra Collegare la tensione di rete ai morsetti denominati ingresso rispettando la successione delle tre fasi R S T e neutro N ATTENZIONE IL COLLEGAMENTO DEL NEUTRO IN INGRESSO ALLO STABILI ZZATORE ASSOLUTAMENTE NECESSARIO ANCHE SE NON RI CHI ESTO DAL CARI CO Attenzione il collegamento del NEUTRO in ingresso dipende dalla configurazione richiesta per il trasformatore di isolamento posto a monte dello stabilizzatore trifase Il trasformatore fornito di serie con collegamento triangolo stella gruppo vettoriale Dyn come riportato nello schema 2 allegato In questo caso collegare soltanto le fasi R S T Non sar presente in ingresso il morsetto N neutro perch non necessario Nel caso il Vs apparecchio appartenga alla serie RTI stabilizzatore trifase con trasformatore d isolamento con ingresso 230V trifase senza neutro e uscita 400V collegare le tre fasi R S T
17. of failure of the board provided that the above points are properly checked an output voltage can be measured k factor srl GARANZIA L apparecchio come ogni suo componente stato sottoposto ad accurati collaudi ed garantito per un periodo di 12 mesi dalla data di acquisto o non oltre 13 mesi dalla data di spedizione Per data di acquisto si intende quella indicata sulla fattura o ricevuta fiscale rilasciata dal venditore La garanzia sulle parti elettroniche si intende prolungata a mesi 24 Per garanzia si intende la sostituzione o riparazione gratuita dei componenti riconosciuti dalla ditta produttrice inefficienti o difettosi di fabbricazione Per l intervento in garanzia l apparecchio deve essere consegnato o inviato franco di porto al servizio di assistenza pi vicino allegando lettera con dati apparecchiatura descritti nel paragrafo precedente trasporto avverr a rischio e pericolo dell acquirente L apparecchio riparato in garanzia verr restituito all acquirente appena possibile e a sue spese e rischio Sono escluse dalla garanzia le rotture accidentali distruzioni o folgorazioni da eventi naturali i danni provocati da incuria uso ed installazione errati impropri o non conformi alle avvertenze riportate La garanzia decade qualora l apparecchio sia stato manomesso o riparato da personale non autorizzato o abbia subito interventi per vizi o verifiche di comodo E esclusa la sostituzione dell apparecchio o il prolungamento della ga
18. oltage to the terminals marked INPUT respecting the succession of the three phases R S T and neutral N Warning the connection of the neutral on the input of the stabiliser is necessary even if not requested by the load Warning in the RTI range the connection of the neutral on the input side depends from the required connection of the Isolation transformers connected to the stabiliser The isolation transformer is usually supplied with a delta wye configuration Dyn11 vector group in this case input N terminal will not be present but a different connection may be required Please check the label of the Isolation transfomer in your stabiliser for more information If you purchased the RTI stabiliser with input isolation transformer 230Vac 400Vac connect the input cables to the R S T to the input connectors In this case connection of the neutral is still not necessary Warning in the RTI range never change the connections of the isolation transformer Isolation transformer is already connected to the stabiliser nput output connectors of the transformer must not be used for input output connections of the stabiliser If single phase equipments are connected it is always advisable to connect the loads equally on the three lines Single phase loads up to 1 3 of the residual available power of the stabiliser can be connected to each phase once considered the three phase loads Eg Three phase stabiliser RT
19. ontrollo elettronico con regolazione indipendente della squilibrati utilizzan indipendentemente adatti ad operare stabilizzatori trifase dispersione magneti dalle al ca non essere accessibile ed il co trasformatore il col Gli stabilizzatori de trasformatore trifase di la serie iso tensione di uscita su ogni fase caratteristica assolutamente necessaria in presenza di carichi fortemente o infatti tre circuiti di comando e tre servomotori in modo da poter stabilizzare ciascuna fase tre Questa peculiare caratteristica e l elevata affidabilit rendono gli stabilizzatori della serie RTC in qualsiasi condizione in cui sia necessaria una tensione rigorosamente vicina al valore nominale Gli della serie RTC sono montati in armadio metallico sono particolarmente silenziosi e assolutamente privi di introducono distorsioni armoniche Per un corretto collegamento bene ricordare che il neutro deve legamento in uscita avviene sempre a stella Se lo stabilizzatore abbinato in ingresso ad un egamento in entrata pu essere effettuato a stella o a triangolo anche senza neutro RTI accomunano a tutte le caratteristiche della serie RTC i vantaggi dell abbinamento con un amento posto a monte dello stabilizzatore stesso Gli indiscussi vantaggi di tale abbinamento si riassumono in alcune garanzie essenziali la separazione totale della rete con l eliminazione o l attenuazione dei disturbi sulla stessa e la protezione
20. ranzia in caso di intervento E escluso altres il risarcimento di danni diretti o indiretti di qualsiasi natura a persone cose o animali per l uso e la sospensione d uso dell apparecchio GUARANTEE This guarantee is offered as an extra benefit and does not affect your legal rights All the voltage stabilisers and line conditioners are guaranteed by the Company for one year against faulty material or workmanship If any part is found to be defective in this way within the first twelve months from the purchase date we or our authorised service agents we will replace or at our option repair that part without any charge for materials or labour provided that the appliance has been used only in accordance with the instruction provided with each stabiliser and that it has not been connected to an unsuitable electricity supply or subjected to misuse neglect or damage or modified or repaired by any person not authorised by us The correct electricity supply voltage and frequency is shown on the rating plate on the appliance This guarantee is normally available only to the original purchaser of the appliance but the company will consider written applications for transfer Should any defect arise in any voltage stabilisers or line conditioners a claim under guarantee become necessary the appliance should be carefully packed and returned to your local service agent This copy of the guarantee should be attached to the appliance Guarantee is applied only
21. relevare una tensione diversa da quella nominale entro i limiti del 5 regolando la vite OUT CONTROL anche per una singola fase Ricordate tuttavia che tarando l apparecchio su una tensione inferiore la potenza disponibile diminuisce della stessa percentuale Lo stabilizzatore pronto ad entrare in esercizio 6 NORME PARTICOLARI PER SERIE RT TRIANGOLO 220 o 230V Nel caso abbiate acquistato uno stabilizzatore trifase in configurazione 220 o 230 per reti non dotate di neutro il collegamento in entrata e uscita e tutte le regolazioni vanno effettuate allo stesso modo ricordando le seguenti avvertenze morsetti di ingresso e uscita sono privi del morsetto N neutro Il collegamento del neutro non previsto n necessario per il funzionamento dell apparecchio Il voltmetri in entrata e uscita leggono le tensioni tra fase e fase RS ST RT Dovranno pertanto indicare in caso di corretto funzionamento 230V 15 in ingresso 230V 1 in uscita 7 NORME PER UN CORRETTO UTILIZZO MANUTENZI ONE 1 Lo stabilizzatore non deve operare in ambienti polverosi o in presenza di agenti chimici corrosivi 2 Non pulire mai la superficie dell apparecchio con prodotti aggressivi Non usare olio o solventi chimici 3 Non utilizzare mai l interruttore magnetotermico dello stabilizzatore come interruttore generale dell apparecchio utilizzatore Tale operazione se ripetuta nel tempo pu a lungo andare danneggiare l appare
22. type WorvVAisaro dalai E inserted absorption shown on the rating plate of the stabiliser F remarked defect ii talia lai RTI 400V 15 400V N 1 50 60Hz 20 1000 sec Volt any 0 100 less than 1 fino a 6kV a 100 gt 40 dB qualsiasi 94 98 10 C 40 C part no weight RTIO6K 102 RTIO9K 116 RTI12K 134 RTI15K 156 RTI22K 198 RTI30K 216 k factor srl RT Range Stabilisers TROUBLE SHOOTI NG PROCEDURE PROBLEM NO 1 The output voltage is unstable compared with the fixed value or rotating the fine regulation knob the output voltage does not change accordingly SOLUTION Check if the variable transformer s brushings are worned out or are sticked If positive Clean the road on that the brushings run Check their wear s state and eventually replace them Check the correct working of the micro motor to avoid slidind between shaft and join If negative Replace the control electronic card PROBLEM NO 2 The voltmeter marks 000 or it is turned off SOLUTION Check the 3 supply wires are strictly solded and that the voltage supply is 5V Replace the electronic card PROBLEM NO 3 The output voltage is OV in one or more phases SOLUTION Check the input voltage of each phase The voltage must be between the nominal limits of the stabiliser Check the proper connection of the series transformers Check the efficency of the circuit breaker Note Even in presence
23. ull uscita come riportato nello schema 1 La serie RTI composta da uno stabilizzatore della serie RT e da un trasformatore di isolamento di potenza adeguata 3 CARATTERISTICHE ELETTRI CHE Di seguito sono citate le caratteristiche elettriche degli apparecchi stabilizzatori La tensione di uscita mantenuta costante entro il 1 del valore nominale nelle seguenti condizioni tensione compresa tra 340V e 460V trifase frequenza 50 60Hz carico compreso tra 0 e 100 Quando varia la tensione di ingresso un impulso di regolazione muove la spazzola del variatore che attraverso il trasformatore serie aggiunge o sottrae diversi valori di tensione per rientrare nell errore stabilito La velocit di regolazione stimata in ca 20msec per ogni Volt da regolare Gli stabilizzatori della serie RTC RTI non risentono delle variazioni del fattore di potenza cos phi del carico Il rendimento a pieno carico ca il 94 98 secondo i modelli Lo stabilizzatore protetto da un interruttore magnetotermico quadripolare di portata adeguata 4 COMANDI E STRUMENTAZI ONE Sul pannello superiore sono presenti f Voltmetro digitale Commutatore lettura voltmetro ingresso uscita Commutatore lettura voltmetro su ogni fase e lettura tensione concatenata Trimmer regolazione fine della tensione in uscita per ogni fase Interruttore automatico di protezione Lampada spia di funzionamento RTI N vg Qo 3 z RTI RT RTI