TSol503 - Ipersolar
Contents
1. 2 INSTALLATION 2 1 INSTALLING A Before doing any operation make sure that the Main Power Supply is OFF PL PG O O O 2 e z n VV VV VV VV Cx8 Vx5 Hx2 Fig 1 Components Qu elettronica Pag 9 di 20 TSol503 Manual V1 0 e Install TSol503 only in dry ambient and in correct climatic conditions e Fix the Box with fixing points F e Take away the lid that cable block P e Insert the connecting cables through cablethrough C that are in the points CC of the Box e The box has 8 outputs for the cables if more inputs are necessary USE multipolar cables but put together only cables of the same type e Do the electrical connections e Put the controller n the Box and put the cable in order to facilitate the insertion e Block cable through the cable block P with screws W in points VV e Fix the controller through screws H in points HH e Insert the plate PL 2 2 ELECTRICAL CONNECTIONS For a correct and safe functioning make always the electrical connections to earth Make ordered connections and separate low tension signals probes contacts cables of the control board from high tension signals supply loads to reduce interference problems S1 S2 S3 Probes PT1000 P3 P4 Supplied outputs 230 Vac P5 In Exchange Contacts Output Higt Voltage Zone Lato Alta Tensione lac i i Fig 2 Electrical Connections 3 PROBES INSTALLATION TSoI503 ma
2. Main Menu PASSWORD e Push P3 to select the first digit 0 e Select the value with P4 and P6 1 e Confirm the value with button P3 10 rs e Repeat until the 4th digit 1234 e Confirm the password with the button P3 eWith P1 digit are deleted When it is in the this Menu for long time without pushing any button the system automatically enter in the User s Menu 6 4 SETTINGS Contains thermostats hysteresis parameters of the default functions in the selected plant 6 5 THERMOSTATS Contains thermostats and hysteresis for the management of the selected plant Qu elettronica Pag 13 di 20 TSol503 Manual V1 0 6 6 PARAMETERS Contains timer parameters counters for the management of the selected plant 6 7 FUNCTIONS From the main menu select the function from the available 6 7 1 BUCKET CHARGE This function increases the collectors temperature in conditions of low radiation In case of differential between the probes S1 and S2 but the temperatures S1 and S3 are both less than thermostat THS301 the solar pump is managed with time TIMOO1 Pause and TIMOO2 Work to allow the increase of the solar fluid temperature until the value THS301 The cycle Pause Work is repeated for a number of time COUOO0 then the function is deactivated for a time TIMOOO Jn the end the function starts again in case of right conditions N B In The systems with stratification ac
3. deviata verso l uscita Acqua Sanitaria THS305 Isteresi relativa al termostato THS305 HYS305 5 3 INTEGRAZIONE CALDAIA Parametri per la gestione della Integrazione Caldaia DESCRIZIONE Code Termostato su S3 sotto il quale si abilita l uscita relativa all Integrazione Caldaia THS302 Isteresi termostato THS302 HYS302 5 4 RAFFREDDAMENTO SOLARE Parametri per la gestione del raffreddamento del circuito solare per sovratemperatura DESCRIZIONE Code Termostato su S1 sopra il quale il fluido collettore convogliato verso il raffreddatore THS104 Isteresi termostato THS104 HYS104 Termostato su S1 sopra il quale la Pompa solare provvede a caricare il Boiler Piscina portandoli ai THS100 loro termostati di massima Isteresi termostato THS100 HYS100 Termostato su S3 di massima del Boiler Piscina THS303 Isteresi termostato THS303 HYS303 Termostato su S1 sopra il quale viene bloccata la Pompa del circuito solare THS103 Isteresi termostato THS103 HYS103 5 5 PROTEZIONE PANNELLO Parametri per la gestione della funzione protezione pannello una serranda tenda di copertura pannello DESCRIZIONE Code Termostato su S1 sopra il quale si attiva l uscita Protezione Pannello es serranda tenda THS103 Isteresi termostato THS103 HYS103 6 MENU Il Menu suddiviso in gt Menu Installatore nel quale sono disponibili tutti i parametri de
4. TSOLSOS TERMOREGOLATORE PER CONTROLLO IMPIANTI CON PANNELLI SOLARI TERMICI TEMPERATURE CONTROLLER FOR THERMIC SOLAR PANEL SYSTEMS Qu elettronica Pag 1 di 20 750 503 Manual V1 0 1 INTRODUZIONE Generalit Il sistema di controllo 750 503 uno strumento per la gestione di impianti solari a Circolazione Naturale e Forzata costituiti in genere da Pannello Solare Boiler Accumulo Piscina Integrazione e Sistemi di Protezione Raffreddamento Norme di Sicurezza Leggere attentamente le note sulla sicurezza riportate di seguito cos da prevenire eventuali danni e pericoli alle persone e ai beni Prima di eseguire lavori sull impianto attenersi alle norme antinfortunistiche alle norme sulla protezione ambientale alle norme dell Istituto Nazionale per l Assicurazione contro gli Infortuni sul Lavoro alle norme di sicurezza riconosciute Queste istruzioni per l uso si rivolgono esclusivamente al personale tecnico I lavori elettrici devono essere eseguiti solo da tecnici qualificati in elettrotecnica La prima messa in servizio dell impianto deve essere eseguita da personale esperto o dal fabbricante o da un tecnico da lui nominato Dichiarazione di Conformit Norme applicate EN 60730 1 50081 1 EN 60730 1 A1 50081 2 TiEmme elettronica 06055 Marsciano PG Italy Tel 39 075 874 3905 Fax 39 075 874 2239 info tiemmeelettronica it Composizione del Prodotto Dati Tecnici N 01 750 503 Alim
5. IMPIANTO 5 PLANT 5 Carica Boiler a Circolazione Naturale Innalzamento Boiler Charge Natural Circulation Sanitary Sanitario Integrazione Caldaia Protezione Pannello Increasing Boiler Integration Panel Protection P5 dino 12NC 13 Com Integrazione Caldaia Boiler Integration P4 9 10 Protezione Pannello Pane Protection P3 7 8 Valvola Sanitario Sanitary Valve S1 314 15 Sonda Collettore Collector Probe S2 16 17 Sonda Boiler basso Low Boiler Probe S3 18 19 Sonda Boiler alto High Boiler Probe IMPIANTO 6 PLANT 6 Carica Piscina Protezione Pannello Pool Charge Panel Protection P5 dino 12NcC 13 Com Non Utilizzato Not used x P4 9 10 Pompa Piscina Pool Pump i P3 7 8 Protezione Pannello Panel Protection S1 314 15 Sonda Collettore Collector Probe El sie S2 16 17 Sonda Piscina basso Low Pool Probe paid 3 S3 18 19 Sonda Piscina alto High Pool Probe IMPIANTO 7 PLANT 7 Carica Piscina con Scambiatore Protezione Pannello Pool Charge with Exchanger Panel Protection P5 11N 0 12N c 13 com Pompa Piscina Pool Pump kj P4 9 10 Pompa Solare Solar Pump i P3 7 8 Protezione Pannello Panel Protection S1 14 15 Sonda Collettore Collector Probe ERA isci 3 S2 16 17 Sonda Piscina basso Low Pool Probe MET S3 18 19 Sonda Piscina alto High Pool Probe PS IMPIANTO 8 PLANT 8 Carica Boiler a Circolazione Naturale Innalzamento Boiler Charge Natural Circulation Sanitary Sanitario Integrazione Caldaia Protezione Pannello Increasing Boiler
6. The Controller TSOI503 is for the management of Solar Plants with Natural and Forced Circulation with a Solar Panel Accumulatiory Boiler Pool Integration and Systems of Protection Cooling Safety regulations Read carefully the following safety regulations in order to prevent damages and danger to people and things Before working on plants follow e Accident prevention measures Environmental protection measures National Institute for Work accidents measures Recognized prevention measure Directions are only for technical staff Electrical works must be done only by qualified technicians e The first installation of the plant must be done by expert personal or by the builder Declaration of Conformity Rules EN 60730 1 50081 1 EN 60730 1 A1 50081 2 TiEmme elettronica 06055 Marsciano PG Italy Tel 39 075 874 3905 Fax 39 075 874 2239 info tiemmeelettronica it Product composition Technical data N 01 TSOI503 Supply 230 Vac 50 Hz N 04 screws and plugs Input 2 VA N 02 screws for controller s fixing Capacity SA 250 Vac N 01 Box Internal fuse 3 15 A N 01 Plate Protection grade IP40 N 01 Kit Probe PT1000 Reading probes PT1000 Measure Range 40 300 C Installing and Use Conditions Mechanical Characteristics Functioning temperature 0 40 C Material ABS Plastic Storage temperature 0 60 C Installing Wall Panel Humidity 85 25 C Dimension 160 x 90 x 58 mm Display Graphic Backlight 128x64
7. Function Boiler is activated through the Cooling and or Solar Circuit THS202 Hysteresis thermostat THS202 HYS202 Thermostat of maximum on S2 that Boiler Pool can reach THS203 Thermostat hysteresis THS203 HYS203 5 2 SANITARY INCREASING Parameters for the Sanitary Valve management DESCRIPTION Code Thermostat on S3 over the Sanitary Valve is deviated to the sanitary water output THS305 Thermostat hysteresis THS305 HYS305 5 3 BOILER INTEGRATION Parameters for the Integration Boiler management DESCRIPTION Code Thermostat on S3 under the Boiler Integration output is activated THS302 Thermostat hysteresis THS302 HYS302 5 4 SOLAR CIRCUIT COOLING Parameters for the Cooling management of the solar circuit for over temperature DESCRIPTION Code Thermostat on S1 over the collector fluid is convoyed to the Cooler THS104 Thermostat hysteresis THS104 HYS104 Thermostat on S1 over the solar pump charges the boilers pool and takes them to the maximum THS100 thermostats Thermostat hysteresis THS100 HYS100 Maximum thermostat on S3 Boiler Pool THS303 Thermostat hysteresis THS303 HYS303 Thermostat on S1 over the solar pump charge boiler is blocked THS103 Thermostat hysteresis THS103 HYS103 5 5 PANEL PROTECTION In the following schema are the thermostats and hysteresis of the function panel s protection managed for example with a tent shutter to cover the panel DESCRIPTION Code Thermostat on S1 over the output Protection Panel is activate
8. Integration Panel Protection P5 dino 12NC 13 Com Integrazione Caldaia Boiler Integration P4 9 10 Non Utilizzato Not used P3 7 8 Valvola Sanitario Sanitary Valve S1 14 15 Non Utilizzato Not used S2 116 17 Non Utilizzato Not used S3 118 19 Sonda Boiler Boiler Probe Qu elettronica Pag 17 di 20 750 503 Manual V1 0 8 TERMOSTATI E PARAMETRI THERMOSTATS AND PARAMETERS m Funzione Range U Descrizione Code Description i Function win Set Max Termostato differenziale S1 S2 THD120 Differential thermostat S1 S2 Carica 1 630 per la Carica del Boiler Piscina to activate the Boiler Charge Boiler Piscina Boiler Pool Isteresi parametro THD120 HYD120 Parameter hysteresis THD120 du 1 2 5 C Termostato differenziale S1 S3 THD130 Thermostat differential S1 S3 Stratificazione 1 3 s0 c per attivare la Stratificazione to activate Stratification Stratification Termostato su S1 sopra il quale la Thermostat on S1 over the Solar cian Pompa solare carica il Boiler fino THS100 Pump charges the Boiler until the ola 80 95 200 C ai Termostati di Massima Maximum Thermostats Collector Isteresi parametro THS100 HYS100 Parameter hysteresis THS100 protection 0 2 25 Termostato su S1sotto il quale si Thermostat on S1 under the attiva la funzion
9. automatico e viceversa DESCRIZIONE Code Termostato su S3 sotto il quale viene avviata la funzione Carica a Secchi THS301 Isteresi termostato THS301 HYS301 Tempo di disattivazione della Funzione Carica a Secchi dopo COUDO fermate della Pompa TIMOOO0 Tempo di Pausa della Pompa durante la funzione TIMOO1 Tempo di Lavoro della Pompa durante la funzione TIMOO2 Numero massimo di fermate della Pompa durante la funzione Carica a Secchi COU000 Abilitazione della funzione Carica a Secchi ENA000 6 7 2 HOLIDAY Con la funzione Holiday si imposta il funzionamento del sistema durante lunghi periodi di inutilizzo Quando la funzione abilitata il sistema Effettua il raffreddamento del Boiler Disabilita l Integrazione Caldaia Esegue il Raffreddamento del Boiler attraverso il Circuito Solare DESCRIZIONE Code Termostato su S2 oltre il quale il sistema raffredda il Boiler quando si crea differenziale S1 S2 negativo THS201 Isteresi termostato THS201 HYS201 Abilitazione della funzione Hoilday ENA002 6 7 3 ANTIGHIACCIO Contiene i Termostati Isteresi Parametri relativi alla funzione Antighiaccio Se la temperatura su S1 e inferiore al termostato THS101 viene attivata la Pompa Solare in modalit Pausa Lavoro DESCRIZIONE Code Termostato sotto il quale si abilita la funzione THS101 Isteresi termostato THS102 HYS101 Tempo sec di Lavoro della Pompa durant
10. Probe Temperature Tae Probe in short circuit T2 Short Unconnected Probe or Broken T3 Open Fig 4 Monitor Menu With button P4 enter menu Statistics to consult the current ALARM states and other information Sys 1 Plant Number Statistics Sys 1 Alarms read Alarm Code A02 Other possible information Fig 5 Statistics Menu 4 2 ALLARMI DESCRIPTION DISPLAY Collector s over temperature temperature on S1 more than Thermostat THS103 A01 Boiler s over temperature Temperature on S2 more than Thermostat THS203 A02 Collectors De Ice temperature on S1 less then Thermostat THS101 A03 Probe Error probable probe s break the probe could be unconnected A04 Probe Error probable probe break the probe is in short circuit A05 4 3 PLANTS SURVEY Fig 6 Plants Qv elettronica Pag 11 di 20 750 503 Manual V1 0 5 DEFAULT FUNCTIONS 5 1 BOILER POOL MANAGEMENT Parameters of the management of Boiler Pool charge DESCRIPTION Code Running s Thermostat Boiler Pool on S3 THS300 Hysteresis thermostat THS300 HYS300 Differential thermostat S1 S2 for Boiler pool charge THD120 Thermostat hysteresis THS102 HYD120 Thermostat of minimum on S1 under the solar circuit pump is deactivated THS102 Thermostat hysteresis THS102 HYS102 Thermostat on S2 over the Cooling
11. Quando si nel Menu Installatore senza digitare alcun tasto per un tempo prolungato il sistema va automaticamente in Menu Utente 6 4 IMPOSTAZIONI Contiene Termostati Isteresi Parametri relativi a Funzioni che sono di Default nell Impianto selezionato 6 5 TERMOSTATI Contiene tutti i Termostati e relative Isteresi presenti per la gestione dell Impianto selezionato Qu elettronica Pag 6 di 20 TSol503 Manual V1 0 6 6 PARAMETRI Contiene tutti i parametri Timer Contatori presenti per la gestione dell Impianto selezionato 6 7 FUNZIONI Dal Menu Principale selezionare la funzione fra quelle disponibili 6 7 1 CARICA A SECCHI La funzione ha lo scopo di innalzare la temperatura di collettore in condizioni di scarso irraggiamento Nel caso in cui c differenziale fra Sonda S1 e Sonda S2 ma le temperature S1 e S3 sono entrambe inferiori al termostato THS301 la Pompa solare viene gestita secondo i tempi TIMOO1 Pausa e TIMOO2 Lavoro per favorire l innalzamento della temperatura del fluido solare fino al valore THS301 Il ciclo di Pausa Lavoro viene ripetuto per un numero di volte pari a COU000 quindi la funzione disattivata per un tempo pari a TIMOOO AI termine di questo tempo la funzione riprende se sussistono le condizioni N B Negli impianti in cui presente Stratificazione abilitando la funzione Carica a Secchi la funzione di Stratificazione disattivata in modo
12. Y Sovratemperatura di Collettore Temperatura su S1 maggiore del termostato THS103 A01 Sovratemperatura Boiler Temperatura su S2 maggiore del termostato THS203 A02 Antighiaccio Collettore temperatura su S1 minore del termostato THS101 A03 Anomalia Sonda probabile rottura della sonda la sonda sembra essere scollegata A04 Anomalia Sonda probabile rottura della sonda la sonda crea un cortocircuito A05 4 3 PANORAMICA IMPIANTI Fig 6 Impianti Qin elettronica Pag 4 di 20 750 503 Manual V1 0 5 FUNZIONI DI DEFAULT 5 1 GESTIONE BOILER PISCINA Parametri per la gestione della carica del Boiler Piscina DESCRIZIONE Code Termostato di Esercizio Boiler Piscina su S3 THS300 Isteresi Termostato THS300 HYS300 Termostato Differenziale S1 S2 per carica Boiler Piscina THD120 Isteresi Termostato Differenziale THD120 HYD120 Termostato di minima su S1 sotto il quale viene disabilitata la Pompa Solare THS102 Isteresi termostato THS102 HYS102 Termostato su S2 sopra il quale si attiva la funzione raffreddamento Boiler attraverso il Raffreddatore THS202 e o il circuito solare Isteresi termostato THS202 HYS202 Termostato su S2 di massima che il Boiler Piscina pu raggiungere THS203 Isteresi termostato THS203 HYS203 5 2 INNALZAMENTO SANITARIO Parametri per la gestione della Valvola Sanitaria DESCRIZIONE Code Termostato su S3 sopra il quale la Valvola Sanitaria
13. arms 6 9 OUTPUTS TEST To verify the output s functioning Select one of the outputs to set them on ON 1 The exit form menu restores automatically the system s state 6 10 LANGUAGE To set the language 6 11 INITIALIZATION To initialize again the system and to choose another plant 6 12 CHANGE PASSWORD To change the enter password from the Installer s Menu 6 13 USER MENU To enter into the User Menu 6 14 KEYBOARD MENU Menu for the Display LCD regulation 6 14 1 CONTRAST REGULATION 6 14 2 MINIMUM LIGHT REGULATION Contrast Regulation O 15 e Set with P4 P6 e Confirm with P3 e P1 to exit Min Light Regulation X 15 e Set with P4 P6 e Confirm with P3 e P1 to exit Qu elettronica Pag 15 di 20 750 503 Manual V1 0 7 IMPIANTI GESTITI MANAGED PLANTS IMPIANTO 1 Carica Boiler Integrazione Caldaia Protezione Pannello Boiler Charge Boiler Integration Panel Protection PLANT 7 1 P5 dino 12NC 13 Com Integrazione Caldaia Boiler Integration P4 9 10 Pompa Solare Solar Pump P3 7 8 Protezione Pannello Panel Protection S1 14 15 Sonda Collettore Collector Probe S2 116 17 Sonda Boiler basso Low Boiler Probe S3 18 19 Sonda Boiler alto High Boiler Probe Ses E i MP5 IMPIANTO 2 Carica Boiler Stratificazione Integrazione Calda
14. d ex Shutter tent THS103 Thermostat hysteresis THS103 HYS103 6 MENU The Menu is divided in gt Installer Menu where are available all the parameters of TSOI503 gt User s menu where are available only the parameters reserved to the final user Qu elettronica Pag 12 di 20 750 503 Manual V1 0 6 1 INSTALLER MENU Settings Contains all the thermostats hysteresis and 9 parameters that the installer sets up Contains all the thermostats and hysteresis used for Thermostats the selected plant Parameters Contains all the parameters used for the selected plant Bucket Charge Holiday a Contains only the functions used in the selected Functions De Ice plant Stratification Pumps DeBlock Statistics Menu for the visualization and reset of the statistic data Pump functioning hours alarms Outputs Test Menu for the outputs functioning test Language To change the language Initialization Re Initialization of the System Change Password For the installer s password change User Menu For the passage to Users menu KeyBoard Menu Display LCD regulation 6 2 FIRST POWER ON At the first Power ON TSoI503 shows the available plants Select the systems With the buttons P4 P6 Confirm the selected PLANT With the button P3 The same function of plant selection is available in the Installer menu with Initialization 6 3 INSTALLER MENU ACCESS
15. e DESCRIZIONE Code Tempo di attesa antiblocco espresso in giorni TIMO19 Tempo di lavoro della pompa in antiblocco espresso in minuti TIMO20 Abilitazione dell uscita P3 al controllo antiblocco pompe P3 Abilitazione dell uscita P4 al controllo antiblocco pompe P4 Abilitazione dell uscita P5 al controllo antiblocco pompe P5 6 8 STATISTICA Permette di consultare lo storico degli allarmi gestiti Attraverso la voce Reset e possibile azzerare tutti i contatori e allarmi 6 9 TEST USCITE Permette di verificare il funzionamento delle uscite Selezionando una delle uscite alla volta possibile portarle tutte nello stato ON 1 L uscita dal menu ripristina automaticamente lo stato del sistema 6 1U0 LINGLIA Consente di impostazione la Lingua 6 11 INIZIALIZZAZIONE Consente di re inizializzare il sistema permettendo di scegliere un altro impianto 6 12 CAMBIA PASSWORD Permette di cambiare la password d accesso al Menu Installatore 6 13 MENU UTENTE Permette di passare al Menu Utente 6 14 TASTIERA LOD Menu di Regolazione del Display LCD 6 14 1 REGOLA CONTRASTO 6 14 2 REGOLA LUCEMINIMA Regola Contrasto Regola Luce Minima e Impostare con P4 P6 e Impostare con P4 P6 O 15 e Confermare con P3 X 15 e Confermare con P3 e P1 per uscire e P1 per uscire Qv elettronica Pag 8 di 20 TSol503 Manual V1 0 1 INTRODUCTION Main
16. e Antighiaccio Tot function De Ice is activated Antighiaccio MM 90 O De l Isteresi parametro THS101 HYS101 Parameter hysteresis THS101 i 0 2 25 C Termostato su S1 sotto il quale Thermostat on S1 under the Solar Carica disabilitata la Pompa Solare Asia Pump is deactivated Boiler Piscina 9 30 40 Boiler Pool Isteresi parametro THS102 HYS102 Parameter hysteresis THS102 podia O 2 25 C Termostato su S1 sopra il quale Thermostat on S1 over the Solar Protezione la Pompa Solare bloccata io Pump is blocked Collettore 80 100 200 Collect Isteresi parametro THS103 HYS103 Parameter hysteresis THS103 Polaca 0 2 25 Termostato su S1 sopra il quale il Thermostat on S1 over the fluido solare va al raffreddatore IDA collector fluid is sent to the Cooler Raffreddatore 70 uM C A Cooli Isteresi parametro THS104 HYS104 Parameter hysteresis THS104 M 0 20 30 C Termostato su S2 sopra il quale si Thermostat on S2 over the Boiler raffredda il Boiler con differenziale THS201 is cooled with negative differential Holiday 20 60 85 C S1 S2 negativo S1 S2 Holiday Isteresi parametro THS201 HYS201 Parameter hysteresis THS201 0 2 25 Termostato su S2 sopra il quale si Thermostat on S2 over the Protezi attiva la funzione raffreddamento THS202 function Boiler cooling is activated POT 20 85 100 Boiler attraverso il circuito solare through the solar circuit Boiler Isteresi parametro THS202 HYS202 Parameter hy
17. e la funzione TIMO12 Tempo min di Pausa della Pompa durante la funzione TIMO13 Abilitazione della funzione Antighiaccio ENA007 6 7 4 STRATIFICAZIONE Nel caso ci sia differenziale S1 S3 viene caricata la zona alta del Boiler fino al termostato THS306 per poi proseguire con la carica della parte bassa fino a soddisfare il termostato THS300 Nel caso non sia presente differenziale S1 S3 ma sia presente differenziale S1 S2 viene caricata la parte bassa del Boiler nella modalit Pausa Lavoro Dopo un numero di Cicli COU001 la funzione viene disattivata per un tempo pari a TIM017 N B Negli impianti in cui presente Stratificazione abilitando la funzione Carica a Secchi disattivata in modo automatico la funzione di Stratificazione e viceversa Qin elettronica Pag 7 di 20 750 503 Manual V1 0 DESCRIZIONE Code Termostato di Stratificazione THS306 Isteresi termostato THS306 HYS306 Differenziale minimo tra Sonda S1 e Sonda S3 THD130 Massimo numero di Cicli Pausa Lavoro della Pompa Solare COUO01 Tempo di Pausa della Pompa durante la funzione Stratificazione TIMO10 Tempo di Lavoro della Pompa durante la funzione Stratificazione TIMO11 Tempo di disattivazione della funzione Stratificazione TIMO17 Abilitazione della funzione di Stratificazione ENAOO8 6 7 5 ANTIBLOCCO POMPE Men per impostare tutti e solo i termostati isteresi parametri relativi alla funzione antiblocco pomp
18. entazione 230 Vac 50 Hz N 04 viti e tasselli Assorbimento 2 VA N 02 viti Fissaggio Centralina Portata Uscite 5A 250 Vac N 01 Contenitore Fusibile Interno 3 15 A N 01 Placca di Copertura Grado di Protezione 1P40 N 01 Kit Sonde PT1000 Sonde di lettura PT1000 Range di Misura 40 300 C Condizioni di Installazione e Utilizzo Caratteristiche Meccaniche Temperatura di funzionamento 0 40 C Materiale ABS Plastica Temperatura di stoccaggio 0 60 C Installazione a Parete Pannello Umidit 85 25 C Dimensioni 160 x 90 x 58 mm Display Grafico BackLight 128x64 2 INSTALLAZIONE 2 1 MONTAGGIO AN Prima di fare qualsiasi operazione assicurarsi che la Tensione di Rete sia disinserita PL P 0 O O O o Q ux VV VV VV VV VV Cx8 Vx5 Hx2 Fig 1 Componenti Qu elettronica Pag 2 di 20 750 503 Manual V1 0 e Installare 750 503 solo in ambienti asciutti e in condizioni climatiche corrette e Fissare il Contenitore tramite i punti fissaggio F e Togliere il coperchio BloccaCavi P e Inserire i cavi di collegamento utilizzando i passacavi C inseriti nei punti CC del Contenitore e Il contenitore dispone di 8 uscite per cavi nel caso siano necessarie pi uscite dal Contenitore UTILIZZARE cavi multipolari avendo cura di assiemare solo cavi della stessa tipologia e Effettuare le connessioni elettriche previste e Inserire la Centralina nel Contenitore avendo cura nel posizionare i cavi
19. ettronica Pag 20 di 20 Zona Industriale Torre Sapienza Via A Ferranti 05 06055 Marsciano PG Italy www tiemmeelettronica it info tiemmeelettronica it The manual is realized with cure and attention but the contained information could be incomplete not exhaustive or with mistakes For this reason the design specifications and contents could change without forewarning during the time according to the product s model TiEmme elettronica is not responsable for incomplete or incorrect information eventually present 750 503 Manual V1 0
20. high boiler zone is charged up to THS306 then the low boiler zone is charged up the thermostat THS300 In case of absence of differential S1 S3 but presence of differential S1 S2 the lower boiler zone is charged in Pause Work modality After a number of cycles COUOO1 the function is deactivated for a time TIMO17 N B In plants with stratification activating the function Bucket Charge the function stratification is automatically deactivated and vice versa Qu elettronica Pag 14 di 20 750 503 Manual V1 0 DESCRIPTION Code Stratification Thermostat THS306 THS306 hysteresis Thermostat HYS306 Minimum differential between probes S1 and S3 THD130 Maximum number of cycles Pause Work of Solar Pump modality COUO01 Pump s Pause time during the Stratification function TIMO10 Pump s Work time during the Stratification function TIMO11 Deactivation time of the Stratification function TIMO17 Stratification function Enable ENAOO8 6 7 5 PUMPS DE BLOCK Menu that sets all the thermostats hysteresis parameters of the Pump De Block function DESCRIPTION Code Waiting Time For the De Block activation in days TIMO19 Pump s Time work in De Block in minutes TIMO20 Enable for P3 Pump s De Block Control P3 Enable for P4 Pump s De Block Control P4 Enable for P5 Pump s De Block Control P5 6 8 STATISTIC To see the list of the managed alarms Reset sets at zero the counters and the al
21. i pompe valvole ecc al fine di evitare problemi di interferenza nella lettura delle temperature Le Sonde possono essere prolungate con cavo 2 x 1 mm fino a 30 mt Utilizzare un cavo schermato nel caso in cui si notano interferenze o disturbi nella lettura delle temperature 4 PANNELLO COMANDI Uso E FUNZIONI Funzioni dei tasti P4 P6 Scorrimento Menu Aumento Diminuzione Valori P3 Ingresso in Menu Salvataggio in Menu P1 Uscita da Menu P5 Funzione speciale Fig 3 Pannello LCD Qu elettronica Pag 3 di 20 TSol503 Manual V1 0 DISPLAY Pompa ON se lampeggia Valvola Direzione Flusso Holiday Funzione Attiva se presente Protezione Pannello ON se lampeggia O Integrazione Caldaia ON se lampeggia I Allarme i in corso m Circuito Raffreddatore 1 Scambiatore a Piastre Piscina ATO Tramite il pulsante P4 si accede al menu Monitor che mostra le temperature misurate dalle Sonde Sys 1 Numero Impianto Monitor Sys 1 Temperatura Sonda T1 70 Sonda cortocircuitata T2 Short Sonda scollegata o interrotta T3 Open Fig 4 Monitor Menu Tramite il pulsante P4 si accede al menu Statistics che mostra gli allarmi correnti e altro Sys 1 Numero Impianto Statistics Sys 1 Allarmi letti Codice Allarme A02 Altre possibili informazioni Fig 5 Statistics Menu 4 2 ALLARMI DESCRIZIONE DISPLA
22. ia Boiler Charge Stratification Boiler Integration PLANT 2 P5 11N0 12 N C 13 Com Integrazione Caldaia Boiler Integration P4 9 10 Pompa Solare Solar Pump P3 7 8 Valv Stratificazione Stratification Valve S1 14 15 Sonda Collettore Collector Probe S2 116 17 Sonda Boiler basso Low Boiler Probe S3 18 19 Sonda Boiler alto High Boiler Probe IMPIANTO 3 Carica Boiler Raffreddatore Integrazione Caldaia Boiler Charge Cooling Boiler Integration PLANT 3 P5 dino 12NC 13 Com Integrazione Caldaia Boiler Integration P4 9 10 Pompa Solare Solar Pump P3 7 8 Ho PN uidi S1 14 15 Sonda Collettore Collector Probe S2 116 17 Sonda Boiler basso Low Boiler Probe S3 18 19 Sonda Boiler alto High Boiler Probe IMPIANTO 4 Carica Boiler Innalzamento Sanitario Boiler Charge Sanitary Increasing PLANT 4 Integrazione Caldaia Boiler Integration P5 dino 12NC 13 Com Integrazione Caldaia Boiler Integration P4 9 10 Pompa Solare Solar Pump P3 7 8 Valvola Sanitario Sanitary Valve S1 14 15 Sonda Collettore Collector Probe S2 116 17 Sonda Boiler basso Low Boiler Probe S3 18 19 Sonda Boiler alto High Boiler Probe TiEmme elettronica Pag 16 di 20 750 503 Manual V1 0
23. l 750 503 gt Menu Utente nel quale sono disponibili solo parametri riservati all utente finale Qu elettronica Pag 5 di 20 TSol503 Manual V1 0 6 1 MENU INSTALLATORE Impostazioni A Termostati un eae i e isteresi utilizzati Parametri LL tutti i parametri utilizzati dall impianto Carica a Secchi Holiday Funzioni Antighiacco Comit tue sole inion che posso esser Stratificazione Antiblocco Pompe Statistica cu Test Uscite Menu per il test di funzionamento delle uscite Lingua Scelta della lingua Inizializzazione Re Inizializzazione del Sistema Cambio Password Menu per il cambio Password Installatore Menu Utente Menu per il passaggio al Menu Utente Menu Tastiera Menu di Regolazione del Display LCD 6 2 PRIMA ACCENSIONE Alla prima Accensione TSol503 si porta nella visualizzazione grafica degli impianti disponibili Scorrere gli impianti con i tasti P4 P6 Confermare l impianto selezionato Con il tasto P3 La stessa funzione di selezione impianto disponibile nel Menu Installatore alla voce Inizializzazione 6 3 ACCESSO AL MENU INSTALLATORE Main Menu PASSWORD e Con P3 selezionare la prima cifra 0 Menu Installatore e Con P4 e P6 selezionare il valore 1 e Confermare il valore con P3 10 e Ripetere la operazione fino alla 4 cifra 1234 e Confermare la PASSWORD con il tasto P3 e Con iltasto P1 vengono cancellate le cifre inserite
24. nages temperature probes PT1000 The reading range is 40 300 C with precision of 1 C If the probe is in short circuit the display shows Short If the probe is unconnected or broken the display shows Open e The probe s range depends on the declared probe characteristics TiEmme elettronica is not responsible for damages or malfunctioning of the probe that are due to a use of it out of the range or due to a break of the cable e The installing of the cables must be separated by the high tension cables like supply pump commands valves in order to avoid interference problems during the temperature reading e Probes can be extended with a 2 x 1 mm cable until 30 mt e Use the shielded cable in case of interference in the temperature reading 4 KEYBOARD USE AND FUNCTIONS Button s functions P4 P6 Run Menu Values Increase decreasei P3 Enter in Menu Savain Menu Pi Exit Menu P5 Special Function Fig 3 LCD Panel Qu elettronica Pag 10 di 20 750 503 Manual V1 0 DISPLAY Pump ON if Blinking Valve Flux Direction Panel Protection ON if Blinking Integration Boiler ON if Blinking Holiday Function Activated if present Alarm s in Course Cooling Circuit Exchanger with Plates Se ei Pool BAT Ow With button P4 enter menu Monitor to consult the current ALARM states and other information Sys 1 Plant Number Monitor Sys 1
25. on Stratification 1 5 60 Min Stratificazione Tempo di Lavoro della Pompa Solar Pump s Work Time Antighiaccio Solare in funzione Antighiaccio Tete During the function De Ice De Ice Y 480 Sec Tempo di Pausa della Pompa Solar Pump s Pause Time Antighiaccio Solare in funzione Antighiaccio unan During the function De Ice De Ice o Y 60 Min Tempo di disattivazione della TT Stratificazione funzione Stratificazione TIM017 Stratification deactivation Time Stratification 1 3 480 hh Antiblocco Tempo di attesa per attivazione TIMO19 Pause Time for the Pompe 4 7 30 Giorni Antiblocco Pompe Pump s De Block Pump activation Pumps Days De Block Antiblocco Tempo di lavoro della pompa in Work Time of the Pump Pompe Antiblocco Pompe TIMBZU in Pump s De Block Pumps 1 E o Min De Block Massimo numero di fermate della Maximum number of stops of the Carico a secchi Pompa solare durante la funzione COUO00 Bucket 1 5 20 Carica a Secchi Solar Pump during Bucket Charge Charge Massimo numero di Cicli Maximum number of Cycles Stratificazion Pausa Lavoro della Pompa Solare COUO01 Pause Work of the Solar Pump Ss cazione 4 5 20 PM olde ratification nella funzione Stratificazione during Stratification function Abilitazione della funzione di Carico a secchi Carica a Secchi ENA000 Bucket Charge Enable Bucket Charge 0 0 1 A Holiday Abilitazione della funzione Holiday ENAO02 Holiday function Enable Holida O 0 1 Abilitazi
26. one della funzione Antighiaccio Antighiaccio ENA007 De Ice function Enable De lce 0 0 1 Abilitazione della funzione DX Stratificazione stratificazione ENA008 Stratification function Enable Stratification 0 1 1 Antiblocco Abilitazione dell uscita P3 al P3 Enable for P3 Output Pompe olo 4 controllo antiblocco pompe Pump s De Block Control Pumps De Block Antiblocco Abilitazione dell uscita P4 al P4 Enable for P4 Output Pompe olo 4 controllo antiblocco pompe Pump s De Block Control Pumps De Block Antiblocco Abilitazione dell uscita P5 al P5 Enable for P5 Output Pompe 01l0 y controllo antiblocco pompe Pump s De Block Control Pumps De Block Qu elettronica Pag 19 di 20 750 503 Manual V1 0 Impianto idraulico impostato Hydraulic Plant set Impostato il Set on Impostato da Set by Note di Installazione Installation Note TiEmme elettronica Zona Industriale Torre Sapienza Via A Ferranti 05 06055 Marsciano PG Italy Tel 39 075 8743 905 Fax 39 075 8742 239 Questo manuale stato realizzato con cura e attenzione tuttavia le informazioni contenute possono essere incomplete non esaustive o contenenti errori Per tale motivo il design le specifiche e i contenuti riportati possono variare senza preavviso nel corso del tempo in base al modello prodotto TiEmme elettronica non si ritiene responsabile per informazioni incomplete o non corrette eventualmente presenti Qu el
27. per agevolarne l inserimento e Bloccare i cavi mediante l apposito BloccaCavi P con le viti in dotazione V nei punti VV e Fissare la Centralina tramite le viti H nei punti HH e Inserire la Placca di copertura PL 2 2 COLLEGAMENTI ELETTRICI Per un funzionamento corretto e sicuro effettuare sempre i collegamenti a terra A Eseguire i collegamenti in maniera ordinata cercando di tenere separati il pi possibile segnali a bassa tensione sonde contatti dai segnali ad alta tensione alimentazione carichi onde ridurre al minimo problemi di interferenza S1 S2 S3 Sonde PT1000 P3 P4 Uscite Alimentate 230 Vac P5 Uscita Contatti liberi in Scambio Higt Voltage Zone Lato Alta Tensione whsw s2 8 Fig 2 Collegamenti Elettrici 3 INSTALLAZIONE SONDE 750 503 gestisce Sonde di temperatura PT1000 Il range di lettura 40 300 C con la precisione di 1 C In caso di Sonda in cortocircuito il display visualizza Short In caso di Sonda scollegata o interrotta il display visualizza Open e Il range di utilizzo della Sonda dipende dalle caratteristiche dichiarate della Sonda utilizzata TiEmme elettronica non responsabile di rotture o malfunzionamenti della sonda dovuti a utilizzo fuori dal range di temperatura o a rotture o interruzioni del cavo e La installazione dei cavi Sonda deve essere separata dai cavi ad alta tensione quali alimentazione comand
28. steresisTHS202 Protection Q 2 25 Termostato su S2 di massima che Thermostat of maximum on S2 the Protezione il Boiler Piscina pu raggiungere poem boiler pool can reach Boiler Piscina 20 80 100 Boiler Pool Isteresi parametro THS203 HYS203 Parameter hysteresis THS203 Sii 0 2 25 C Termostato di Esercizio su S3 del Boiler Pool Running s Thermostat Carica Boiler Piscina THA on S3 Boiler Piscina 10 70 85 Boiler Pool Isteresi parametro THS300 HYS300 Parameter hysteresisTHS300 pois 0 2 25 Termostato su S1 e S3 sotto il Thermostat on S1 and S3 under quale abilitata la Carica a Secchi TESSOI the Bucket Charge is activated dd 20 fim 85 Isteresi parametro THS301 HYS301 Parameter hysteresis THS301 Charge 0 2 25 Termostato su S3 sotto il quale Thermostat on S3 under the Boiler Carica attivata la Integrazione Caldaia bis Integration is activated Boiler Piscina 20 50 85 Boiler Pool Isteresi parametro THS302 HYS302 Parameter hysteresis THS302 pb 0 2 25 Termostato di massima su S3 che Thermostat of maximum on S3 Protezione il Boiler Piscina pu raggiungere Taans the Boiler Pool can reach Boiler Piscina 20 90 100 Boiler Pool Isteresi parametro THS303 HYS303 Parameter hysteresis THS303 cion 0 2 25 C Termostato su S3 sopra il quale la Thermostat on S3 over the Valvola Sanitaria deviata verso THS305 Sanitary Valve is deviated to the Pera 20 50 85 Pusci
29. ta Acqua Sanitaria sanitary water output Sanitary Isteresi parametro THS305 HYS305 Parameter hysteresis THS305 Increasing Q 2 25 Qu elettronica Pag 18 di 20 750 503 Manual V1 0 M es Funzione Range U Descrizione Code Description a i Function win set Max Termostato di Stratificazione su S3 Stratification Function Thermostat Sotto tale termostato si carica la THS306 on S3 Under this thermostat Stratificazi 20 60 85 C i tratificazione parte alta del boiler the high boiler zone is charged Stratification Isteresi Termostato THS306 HYS306 THS306 Hysteresis 0 2 20 RE nm Carico a secchi Tempo di disabilitazione della Function Bucket Charge funzione Carica a Secchi 1109000 deactivation Time d 1 EM 480 Min ge Carico a secchi Tempo di Pausa Pompa durante la rasgo Pump s Pause Time during the Bucket 1 5 60 Min funzione di Carica a Secchi function Bucket Charge Charge Tempo di Lavoro Pompa 7 Carico a secchi durante la funzione di Carica TIM002 dal i i me Bucket 1 5 60 Min Secchi g Charge Tempo di Pausa della Pompa y i T Pump s Pause Time Stratificazione durante la tunziene di TNOTE during the function Stratification Stratification 5 60 Min Stratificazione Tempo di Lavoro della Pompa E Pump s Work Time Stratificazione quien la tuna anon TIMON during the function Stratificati
30. tivating the Bucket Charge Function the stratification function is automatically deactivated DESCRIPTION Code Thermostat on S3 under the function is activated THS301 Thermostat hysteresis THS301 HYS301 Function deactivation time after COU00 pump s stop TIMOOO0 Pump s pause time during the function TIMOO1 Pump s work time during the function TIM002 Maximum number of attempts of the pump during the function COU000 Enable Function ENA000 6 7 2 HOLIDAY The function Holiday is for the setting up of the system during long periods of break When the function is activated the system does Boiler Cooling Deactivation Boilers Integration Boiler Cooling through the Solar Circuit DESCRIPTION Code Thermostat on S2 over the System cools the boiler when there is negative differential S1 S2 THS201 Thermostat hysteresis THS201 HYS201 Enable Holiday function ENA002 6 7 3 DE ICE Contains Thermostats Hysteresis Parameters of the De Ice function If temperature S1 is less than Thermostat THS101 the Solar Pump is activated in modality Pause Work DESCRIPTION Code Under this thermostat the function is activated THS101 Thermostat hysteresis THS102 HYS101 Pump s work time during the function sec TIMO12 Pump s time pause during the function min TIMO13 De Ice function enable ENA007 6 7 4 STRATIFICATION In case of differential S1 S3 the