Manuale trasduttore di posizione magnetico LTS
Contents
1. MANUTENZIONE trasduttori di posizione non richiedono manutenzione Si consiglia di controllare regolarmente i collegamenti elettrici ura di Teoch in si interrompe il LED lampeggia rapidamente Note If the zero point is external to the measurement range the teach procedure is aborted the LED blinks quickly as a result x s If the teach procedure is not concluded there is a timeout after 90 s the last taught in measurement range is active When the sensor is transferred to another actuator it is advisable to activate a reset cycle before starting a new Teach in cycle see point O Check of the taught in measurement range option Change the position of the piston and check the set measurement range using the LED or check the analog output see graph amp I necessary correct the desired measurement range via a renewed Teach in procedure O Resuming the factory set measurement range Press the Teach in button gt 5 s to reset the factory set measurement range maximum measurement range Out of range 4 mA Out of range 3 mA Zero position Final position OK ja O E UJ a JA MAINTENANCE Magnetic position sensors do not reguire any maintenance but the electrical connections should be checked regularly DIMENSIONI SCHEMA ELETIRICO DIMENSIONS WIRING DIAGRAM
2. APNMETL amp WORK PNEUMATIC MANUALE D USO MAGNETIC POSITION TRASDUTTORE DI POSIZIONE SENSOR WITH MAGNETICO CON USCITA ANALOG OUTPUT ANALOGICA SERIE LTS SERIE LTS USER MANUAL O O AVVERTENZE DI SICUREZZA Leggere le istruzioni per l uso primo della messa in esercizio Collegamento montaggio e regolazione solo da parte di personale Si Non un componente di sicurezza secondo la Direttiva macchine EN Utilizzare una fonte di corrente conforme alla norma IEC DIN EN 60204 1 Evitare componenti magneticamente conduttori nelle immediate vicinanze dell LTS Per il collegamento utilizzare cavi totalmente schermati e in generale rispettare le regole generali di collegamento e utilizzo dei segnali analogici MODALIT D IMPIEGO ETS un trasduttore di posizione magnetico destinato a misurare la corsa lineare di azionamenti pneumatici Il trasduttore indicato per tutte le comuni scanalature a T Per garantire il corretto funzionamento necessaria un intensit di campo compresa tra 4 mT e 30 mT La posizione del pistone viene rilevata senza contatto Il segnale di misura viene emesso tramite un uscita analogica di tensione e corrente Il trasduttore dispone sia di un uscita in tensione analogica 0 10 V sia di un uscita in corrente analogica 4 20 mA Il trasduttore attiva solo l uscita che viene cablata Inoltre il trasduttore presenta la funzione Fuori Range di misura definito rispettivamente con
3. un segnale di tensione pari a 11 V quando cablata l uscita in tensione un segnale di corrente pari a 3 mA quando cablata l uscita in corrente vedi grafico Se il pistone si trova all interno del campo di misura si accende il LED ale indicatore di funzionamento Il campo di misura pu essere regolato in modo esatto tramite il pulsante di Teach in punto zero NP punto finale EP Vedere messa in esercizio e E Il Teach in del punto zero NP e del punto di finale EP pu essere effettuato indipendentemente dalla polarit del campo magnetico e dalla posizione del pistone MESSA IN ESERCIZIO Regolazione e fissaggio del trasduttore Collegare il trasduttore alla tensione di esercizio e cablare opportunamente l uscita analogica in corrente o in tensione desiderata vedere schema elettrico Inserire il trasduttore dall alto nella scanalatura a T Portare il pistone nella posizione prescelta come punto zero Il LED si accende quando il pistone all interno del campo di misura Far scorrere il trasduttore nella scanalatura finch il LED si spegne Spingere indietro il trasduttore finch il LED si accende di nuovo Fissare il trasduttore in posizione con accessori idonei All inizio della messa in esercizio l indicatore In range del segnale di ricezione pu essere tremolante Ci significa che il trasduttore ancora in fase di adattamento al campo magnetico La regolazione del campo di misura non indispe
4. L2 a 98 1 Tipologia L1 12 13 Sil al N Arn 115 032 32 5 4 lt DT Li K LTS 064 64 77 72 TED I 4 20 mA 37 1 Indicatore di stato Status indicator O Viti di fissaggio SW1 5 Mounting screw SW1 5 Tasto Teach in Teach in Taste LTS 096 96 109 104 LTS 128 128 141 136 LTS 160 160 173 168 LTS 192 192 205 200 LTS 224 224 237 232 LTS 256 256 269 264 L1 Range di misura Measuring range L2 Lunghezza totale Total lenght L3 Interasse viti Fixing screw spacing get D u 0 10 V bi 3 M DATI TECNICI TECHNICAL DATA Campo di misura corsa mm mm 32 64 96 128 160 192 Measuring range 1 mm mm 32 64 96 128 160 192 224 256 224 256 Alimentazione 15 RONDE Voltage BARDE Ondulazione residua V 10 Residual ripple Vp 10 Connessione elettrica connettore 4 pin M8x Electrical connection Pigtail M8 x 1 plug cavo PUR 300 mm 300 mm PUR cable Tempo di campionamento di lettura ms 1 Sample time ms 1 della posizione Resolution 0 03 FSR gt 0 05 mm O Risoluzione 0 03 FSR gt 0 05 mm O Linearity error type mm 0 3 Errore di linearit tipica mm 0 3 Repeatability 0 06 FSR gt 0 1 mm O Ripetibilit 0 06 FSR gt 0 1 mm O Partial stroke speed type m s 215 Velocit corsa nominale tipica O m s 21 5 Full stroke speed type O O m s lt 3 Velocit corsa completa tipica O O m s lt 3 Analoge output current mA 4 20 Uscita analo
5. V as well as an analog current output 4 20 mA The sensor only activates the wired output The sensor also has an Out of Range Measurement function which is defined by an 11V signal when the voltage output is wired and by a 3mA signal when the current output is wired see graph 89 The a LED lights when the piston is within the measurement range signal strength indicator The desired measurement range can be set precisely Zero Point NP End Point EP in devices with Teach in button See the operation startup O and O The Zero Point NP and End Point EP can be taught independent of the magnetic field polarity and the piston position STARTING OPERATION O Alignment and fixation of the sensor Connect the sensor to the operating voltage and connect the desired current or voltage analog output see wiring diagram Insert the sensor into the slot from above Move the piston into the desired zero point position The yellow LED lights when the piston is in the measurement range The sensor is moved into the slot until the LED switches off Move the sensor back again until the LED lights Secure the sensor appropriately The in range display may flicker at the start of the commissioning process This indicates that the sensor is still teaching in to the magnetic field Setting the measurement range is not absolutely necessary in devices with Teach in button If the user does not Teach in the measurement range the max
6. gica corrente mA 4 20 Analoge output voltage V 0 10 Uscito onologico tensione V 0 10 Out of range analog output current mA 3 Uscita analogica fuori range corrente mA 3 Out of range analog output voltage V 11 Uscita analogica fuori range tensione V 11 Overload protection YES Protezione contro sovraccarichi SI Short circuit protection YES Protezione contro il cortocircuito SI Polarity inversion protection YES Protezione contro l inversione di polarit SI Max load resistance current output 0 500 Resistenza di carico max uscita corrente 0 500 Min load resistance voltage input 0 2000 Resistenza di carico min uscita tensione Q 2000 Black current without load mA 25 Corrente di riposo senza carico mA 25 Protection class III Classe di protezione Ill Enclosure rating IP 67 Grado di protezione IP 67 EMC according EN 60947 5 7 EMC according EN 60947 5 7 IEC 60068 2 6 shock test 30 g 11 ms Shock test IEC 60068 2 6 30 g 11 ms IEC 60068 2 6 vibration test 10 55 Hz 1 mm Test di vibrazione IEC 60068 2 6 10255 Hz 1 mm Ambient operating temperature SE 20 70 Temperatura ambiente se 20 70 Housing material reinforced PA Materiale del contenitore PA rinforzato LED status indicator yellow LED indicazione di funzionamento giallo FSR Full Scale Range max measuring range T 25 C Ub 24V Physical max measuring range lt working stroke magnetic field also outside the max coverage Physical max measuri
7. imum possible range is used as a default Teach in of measurement range option Set the piston position for zero point Press the teach button for 2 s LED blinks 3x s Release the Teach in button the zero point is stored Set the piston position for the end point of the measurement range Press the Teach in button the end point of the measurement range is stored Graph amp shows the output signal NTETAL e WORK PN EU MATI Avvertenza Se il punto zero si trova al di fuori del campo di misura la i 6 volte al secondo Se il Teach in non viene concluso dopo 90 s si ha il timeout in questo caso resta attivo l ultimo campo di misura impostato Ogni qualvolta il trasduttore viene trasferito su un altro attuatore consigliabile effettuare un ciclo di ripristino prima di effettuare un nuovo ciclo di Teach in vedi punto Controllo del campo di misura impostato Cambiare la posizione del pistone e controllare il campo di misura impostato con l aiuto del LED oppure verificare l uscita analogica vedi grafico amp Se necessario correggere il campo di misura ripetendo la procedura di Teach in O Ripristinare il campo di misura impostato in fabbrica Premendo il tasto di Teach in gt 5 s viene ripristinato il campo di misura impostato in fabbrica campo di misura massimo Out of range 10 V ov Zero position Finol position CEEE
8. ng range gt working stroke magnetic field is always recorded The analog measured value can deviate under transient conditions O FSR Full Scale Range campo di misura max T 25 C Ub 24V Campo di misura fisico max lt corsa di lavoro campo magnetico anche al di fuori del rilevamento max Campo di misura fisico max gt corsa di lavoro campo magnetico a rilevamento costante O In caso di interferenze transitorie ci possono essere delle variazioni del valore di misura analogico www metalwork eu ZVAACFO01 ITA GB IMO2 05 2014
9. nsabile Se l utente non effettua il Teach in del campo di misura viene utilizzato di serie il massimo campo di misura possibile Teach in del campo di misura Portare il pistone nella posizione di punto zero Premere per 2 s il tasto di Teach in il LED lampeggia 3 volte al secondo Rilasciare il tasto di Teach in il punto zero cos memorizzato Portare il pistone nella posizione di punto finale del campo di misura Premere brevemente il tasto di Teach in il punto finale cos memorizzato Per la raffigurazione del segnale di uscita vedere il grafico e SAFETY SPECIFICATIONS Read the operating instructions before starting operation Connection assembly and settings only by competent technicians This is not a component in accordance with EU machine guidelines Use a power source according to IEC DIN EN 60204 1 Do not use magnetically e components near the ITS Use fully shielded connecting cables and follow the general rules for connecting and using analogue signals PROPER USE The LTS is a magnetic position sensor and is designed for measuring distances of linear movements on pneumatic drives The sensor is suitable for all standard T slots A field strength of 4 mT to 30 mT is required in order to ensure optimal functionality The piston position is recorded contact free The measurement signal is output via an analoge voltage and current output The sensor is equipped with an analog voltage output 0 10