USER`S MANUAL MANUALE UTENTE
Contents
1. 5 1 6 INIMA M LIE 5 2 DESCRIZIONE DEI SIMBOLI D USO COMUNE 6 3 INTRODUZIONE 1 5 iii 7 4 DESCRIZIONE DEL PANNELLO 8 5 COLLEGAMENTO E FUNZIONAMENTO 12 5 T ISPEZIGNES 12 2 ERA RR tetera uaa eh Du E UE 12 5 3 RICARICA DELLA BATTERIA nennen tenere nere nen 14 DIA ACCENDERE E UPS 14 5 5 PROVA FUNZIONALIT a tta Duca 15 SPEGNERE eS dae eei 15 5 7 FUNZIONE ALLARME ACUSTICO MUTO 16 5 8 PROCEDURA OPERATIVA DELLA BATTERIA ESTERNA PER 1 MODELLI A LUNGA AUTONOMIA MODELLO KS partico 16 6 MODALITA OPERATIVE PER TUTTI I MODELLI 18 6 1 MODALIT NORMALE odi t o mds 18 6 2 MODALIT BATTERIA x as arti I As situa 19 6 3 MODALITA BYSBASS 2 orto elabora 20 6 4 MODALIT DUTIES edebat boe ttr 21 6 5 MODALIT EPO EMERGENCY POWER 22 6 6 MODALIT ECO MODALIT A RISPARMIO ENERGETICO 25 6 7 MODALIT CONVERSIONE cs itti itte nl
2. 50 60Hz 208 220 230 240 Vac BYPASS OFF La modalit by pass L UPS non ha la funzione di backup quando in modalit by pass La corrente usata per la ricarica delle batterie viene fornita dalla rete di alimentazione tramite filtro interno 6 4 Modalit No output Il display LCD in modalit No output mostrato nel diagramma sottostante Sono visualizzati i dati relativi all alimentazione alla batteria al carico e all uscita del UPS Il codice 0 indica che PUPS sta lavorando in modalit No output 21 1L o Z gt I 1 1 1 1 gt lt un r N CHARGING BATTERY OUTPUT SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF La modalit No output 6 5 Modalit EPO Emergency Power Off Essa viene anche chiamata RPO Remote Power Off Sul display LCD il codice della modalit 0 la parola indicata nella posizione della tensione d uscita uno stato speciale nel quale l UPS spegne la tensione in uscita e indica l allarme Non possibile accendere il pannello UPS premendo il tasto ON sul pannello ci potr avvenire solo dopo aver sbloccato lo stato EPO innestando l interruttore spegnendo e riavviando l UPS 6 6 Modalit ECO modalit a risparmio energetico chiamata anche modalit ad alto rendimento Nella modalit ECO il codice della modalit visualizzato il 5
3. n DB 9 Interface of AS400 communication protocol 35 12 Software Free Software Download WinPower WinPower is a brand new UPS monitoring software which provides user friendly interface to monitor and control your UPS This unique software provides safely auto shutdown for multi computer systems while power failure With this software users can monitor and control any UPS on the same LAN no matter how far from the UPSs Manager er1 0 agent Read E lzl x System Logs UPS Tools Monitor Preference Language Help UPS Status UPS Normal BYPASS Frequency Max Volt On Battery Min Volt 020000 Model E Voltage 401 Vv Com Port BATTERY Standard 360 V Temp 100 Capacity 1000 A 2004 10 28 13 53 35 Agent Start Installation procedure 1 Go to the website http www ups software download com winpower htm 2 Choose the operation system you need and follow the instruction described on the website to download the software 3 When downloading all required files from the internet enter the serial No 511C1 01220 0100 478DF2A to install the software When your computer restarts the WinPower software will appear as a green plug icon located in the system tray near the clock 36 Appendix Rear panel USB Intelligent Slot External Battery Socket Cooling Fan For S Model Only Breaker Output Socket Network Fax Modem Surge Protecti
4. tenente 22 0 7 CONVERTER MODE 23 6 8 ABNORMAL MODEM b ERU patet 23 7 SETTING BY LCD 24 8 TROUBLE 4 222222222111 27 9 MAINTENANCE 2 422 4 2 1 31 S OPERATIONS lalla 31 ester el 31 9 3 BATTER liana 31 10 2 o kae cose 32 ELECTRICAL SPECIFICATIONS eet itcr oblatis abb 32 10 2 OPERATING ENVIRONMENT aaa 32 10 3 TYPICAL BACKUP TIME TYPICAL VALUES AT 25 IN MINUTES 33 10 4 DIMENSIONS AND WEIGHTS i 33 11 COMMUNICATION PORT 34 TTD SB Beet rto o il i a 34 11 2 RS232 INTEREAGE OPTION iaia 34 11 3 AS400 INTERFAGE OPTION ille 34 12 SOETWARE clelia 36 APPENDIX REAR PANEL 37 1 ISTRUZIONI DI SICUREZZA E DIRETTIVA 1 ede en dtes 1 1 2 FUNZIONAMENTO aad nandi anb indc 2 1 3 MANUTENZIONE RIPARAZIONE E 3 IATRASFPORIO dictata ax A EU eta a aM eR an 4 1 5 STOCCAGGIO
5. Notify dealer 29 Please have following information at hand before calling the After Sales Service Department 1 Model number serial number 2 Date on which the problem occurred 3 LCD display status Buzzer alarm status 4 Utility power condition load type and capacity environment temperature ventilation condition 5 The information battery capacity quantity of external battery pack if the UPS is S model 6 Other information for complete description of the problem 30 9 Maintenance 9 1 Operation The UPS system contains no user serviceable parts If the battery service life 3 5 years at 25 ambient temperature has been exceeded the batteries must be replaced In this case please contact your dealer 9 2 Storage If the batteries are stored in temperate climatic zones they should be charged every three months for 1 2 hours You should shorten the charging intervals to two months at locations subject to high temperatures 9 3 Battery Replace If the battery service life has been exceeded the batteries must be replaced Battery replacement should be performed only by qualified personnel It recommends to shut off the UPS completely before the replacement If there is a battery breaker then turn it off first Disconnect the battery cable carefully and make sure no any exposed wires can be touched Reconnect the new batteries to the UPS by following section 5 8 Then turn on the bat
6. Causa possibile Soluzione Nessuna indicazione nessun segnale di avvertimento anche se il sistema collegato alla rete elettrica Nessuna tensione in entrata Controllare la presa collegata alla rete e il cavo in entrata Visualizzazione del codice 1 anche se disponibile la corrente elettrica L inverter non acceso Premere l interruttore ON Sul display LCD viene visualizzato il codice 3 e il disp Emette un suono di allarme ogni 4 secondi Alimentazione di rete guasta o la potenza in ingresso e o la frequenza sono fuori tolleranza Passare alla modalit batteria automaticamente Controllare la sorgente elettrica in entrata ed informare il fornitore se necessario Tempo della fornitura d emergenza inferiore al valore nominale Batterie non ricaricate completamente batterie difettose Ricaricare le batterie per almeno 5 8 ore e poi controllare la capacit Se il problema persiste contattare il fornitore Guasto alla ventola Funzionamento della ventola anormale Controllare che la ventola sia in funzione Tensione batteria in sovratensione La batteria sovraccaricata Passaggio automatico alla modalit batteria e dopo che la tensione della batteria diviene normale e la corrente torna alla norma l UPS torner di nuovo alla modalit normale Batteria bassa Guasto al caricabatterie Elevata temperatura DC DC La tensione d
7. Dopo che l UPS viene acceso la corrente usata la ricarica fornita dalla rete di alimentazione tramite filtro interno mentre la corrente in ampiezza normale in modo che possa essere acquisito 22 l alto rendimento in modalit ECO Quando si verifica assenza di rete oppure essa anormale l UPS passer in modalit batteria e la ricarica verr fornita in maniera continuativa dalla batteria 1 Pu essere attivato dalle impostazione del display LCD oppure da software Winpower ecc 2 necessario notare che il tempo di passaggio dell UPS dalla modalit ECO a quella batteria inferiore ai 10ms Ma questo troppo lungo per alcuni carichi sensibili 6 7 Modalit conversione Nella modalit conversione il codice visualizzato il 6 L UPS potrebbe funzionare liberamente con frequenza di uscita fissa 2 o 60Hz in modalit conversione Quando si verifica una assenza di rete oppure essa anormale l UPS passer in modalit batteria e la ricarica verr fornita in maniera continuativa dalla batteria 1 essere attivato dalle impostazione del display LCD oppure da software Winpower ecc 2 Il carico dovrebbe essere declassato a massimo il 60 del carico nominale in modalit conversione 6 8 Modalit anormale In modalit anormale come ad es errore di Bus ecc il codice errore corrispondente verr visualizzato per indicare la modalit operativa dell UPS Verranno visualizza
8. Hz i Indicates the frequency value of the UPS output voltage which could be displayed from 0 to 99Hz 1 DO Indicates the UPS output current value which could be displayed from 0 to 99 9A Load Information Indicates the load or the UPS output is short and SHORT the UPS would shut down ORB Indicates the load is over the SPEC range Indicates the load percent and the lowest grid Ez represent 3090 load the two low grids represent 60 load the three low grids represent 90 load all the grids represent 100 load Battery Information Indicates the battery voltage value which could be displayed from 0 to 999Vdc 2a Indicates the battery current value which could be pur displayed from 0 to 99 9A E Indicates the battery capacitance percent and every grid represent 2596 capacitance All the grids represent 100 capacitance Indicates the UPS is working in the battery mode DISCHARGING the battery is discharged for supplying the oa ndicates the battery is being charge CHARGING Indicates the battery is being charged ndicates the battery is over charged an e OVER Indicates the battery i harged and th VOLT UPS would be switched to Battery mode Indicates the battery is weak and the UPS would LOW shut down soon UPS status Information DI x Indicates some the warning or fault o
9. Line mode is shown in the following diagram The information about the utility power the battery the UPS output could be displayed The 2 code indicate the UPS is working in Line mode 18 c 1 E ss TU Lena n D a N N Lh L lt 53 gt lt CHARGING BATTERY OUTPUT SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF The Line mode If output overloaded the icon OVER LOAD is shown and alarm will keep twice every second You should get rid of some unnecessary loads one by one to decrease the loads connected to the UPS less than 909 of its nominal power capacity Note Please follow the following steps to connect the generator Activate the generator and wait until the operation is stable before supplying power of the generator to the UPS be sure that the UPS is in idle mode Then turn on the UPS according to the start up procedure After the UPS is turned on then the loads can be connected to the UPS one by one e The power capacity of the AC generator should be at least twice of the UPS capacity 6 2 Battery mode The LCD display in battery mode is shown in the following diagram The information about the utility power the battery the UPS output and the load could be displayed The 3 code indicate the UPS is working in the battery mode 19 e When UPS is running in battery mode the buzzer beeps once every 4 sec
10. are fasten install the terminal block cover on the rear panel of the UPS 8 lt Connect the UPS to the load Then turn on the mains switch or connect the power cord of the UPS to utility power supply the battery would start to be charged The Caution A DC breaker must be connected between the UPS and external battery The Caution The output sockets of the UPS system may still be electrically live even if the power supply system has been disconnected or the Bypass switch is on OFF position DC breaker Model No VOLTAGE CURRENT NL120N 1K KS 48Vac 50A NL120N 2K KS 125Vdc 40A NL120N 3K KS 125Vdc 60A 17 6 Operating Mode for Models The different codes could be displayed on the LCD screen corresponding to their own operating modes and they are illustrated as the following table At any time only one normal operating mode or fault mode is presented But the warning even several warnings could appear in a certain normal operating mode at one time And the normal operating mode code and the warning code would be shown circularly Once one fault is come forth then all previous warnings would not be shown again but only the fault code is presented Normal operating mode Code No output mode 0 Bypass mode Line mode Battery mode Battery test mode ECO mode Converter mode Oo Oc 1 0 NN gt 6 1 Line mode The LCD display in
11. cavo verde giallo Il cablaggio viene mostrato di seguito dispositivo UPS dotato di interruttore in ingresso sulla carpenteria Consigliamo in ogni caso all utenza di collegare degli interruttori automatici esterni oppure delle componenti di protezione ai cavi in ingresso Si consiglia l uso di interruttori senza fusibile invece del tradizionale set in combinato di interruttore e fusibile Nella scelta dell interruttore senza fusibile l utente pu fare riferimento alla tabella di seguito per informazioni dettagliate in fase di 12 installazione INTERRUTORE SENZA FUSIBILE INGR UPS N Modello TENSIONE CORRENTE 1K 1K KS 300Vac 10A 2K 2K KS 300Vac 20A 3K KS 300Vac 32A 2 Collegamento in uscita dell UPS Le prese in uscita dell UPS sono del tipo IEC Collegare semplicemente il cavo del carico alle prese in uscita per completare il collegamento Usare un cavo per ogni carico da 10A o usare la presa 16A Modello Prese in uscita pz 1K 1K KS 3prese IEC 10A 2K 2K KS 4prese IEC 10A 1presa IEC16A 3K 3K KS 4prese IEC 10A 1presa IEC16A Avvertenza Non collegare dispositivi che possano sovraccaricare il sistema UPS ad es stampanti laser ecc 13 3 Collegamento L EPO Emergency power OFF spegnimento d emergenza configurato NC normalmente chiuso e NC Di norma il connettore EPO chiuso con un cavo sul pannell
12. connecting to the supply Condensation may occur if the UPS is moved directly from a cold to a warm environment The UPS must be absolutely dry before being installed Please allow an acclimatization time of at least two hours Donotinstall the UPS near water or in damp environment not install the UPS where it would be exposed to direct sunlight or near heat Do not connect appliances or items of equipment which would overload the UPS e g laser printers etc to the UPS output Place cables in such a way that no one can step on or trip over them Assure to connect with the earth reliably Assure external battery source must be earthed Connect the UPS only to an earthed shockproof socket outlet building wiring socket outlet shockproof socket outlet must be easily accessible to close to the UPS With the installation of the equipment the sum of the leakage current of the UPS and the connected load does not exceed 3 5MA Do not block ventilation openings in the UPS s housing Ensure the air vents on the front side and rear of the UPS are not blocked Allow at least 25cm of space on each side 1 Air Flow UPS has provided earthed terminal in the final installed system configuration equipotential earth bonding to the external UPS battery cabinets An appropriate disconnect device as short circuit backup protection should be provided in the buildi
13. di corrente Con questo software gli utenti possono monitorare e controllare tutti gli UPS su una stessa LAN a prescindere dalla distanza a cui si trovano gli UPS qm Manager Yer1 0 agent Read _ zl System Logs UPS Tools Monitor Preference Language Help UPS Status UPS Normal BYPASS On Battery 00000 BATTERY Standard i Capacity Voltage 13 53 35 Agent Start Procedura di installazione 1 Andare sul sito web http www ups software download com winpower htm 2 Scegliere il sistema operativo desiderato e seguire le istruzioni riportate sul sito per scaricare il software 3 Scaricando da internet tutti file richiesti digitare il numero di serie 511C1 01220 0100 478DF2A per installare il software Una volta riavviato il computer il software WinPower comparir contrassegnato da un icona rappresentante una spina verde nella barra di sistema vicino all orologio 37 Appendice Pannello posteriore USB Intelligent Slot EPO geg schede opzionali Ventola Presa batteria esterna Interruttore INGRESSO Protezione sovratensioni per rete fax modem Prese in uscita SPINA d entrata USB Intelligent Slot EPO schede opzionali Presa Batteria Esterna Ventole Prese in uscita Interruttore INGRESSO Prese in uscita SPINA d entrata E Protezione Sovratensioni per Rete Fax Modem Vista posteriore di 2K 2K
14. nelle vicinanze di fonti di calore collegare dispositivi o articoli che possano sovraccaricare il gruppo di continuit ad es stampanti laser ecc all uscita dello stesso Collocare i cavi in modo tale che nessuno possa calpestarli oppure inciamparvi Assicurarsi che vi sia una messa a terra affidabile Assicurarsi che l armadio batterie esterno sia messo a terra Collegare l UPS solo ad una presa dotata di messa a terra La presa di rete presa dotata di messa a terra deve essere facilmente accessibile e deve trovarsi nelle vicinanze dell UPS Con l installazione del dispositivo la somma della perdita di corrente dell UPS e del carico collegato non supera i 3 5mA Non bloccare le bocchette di aerazione nell alloggiamento dell UPS Assicurarsi che le bocchette d aerazione frontali laterali e posteriori dell UPS non siano bloccate Lasciare almeno 25cm di spazio su ogni lato L UPS provvisto di terminale di messa a terra e di punto di messa a terra equipotenziale per gli armadi batteria esterni dello stesso La rete di alimentazione deve disporre di un adeguato dispositivo di disconnessone come una protezione contro i cortocircuiti Si prega di vedere le specifiche relative al dispositivo di disconnessione nel capitolo 5 2 Apparecchiatura alimentata da pi di una sorgente elettrica 1 2 Funzionamento Non scollegare mai il cavo di terra dell UPS o la pres
15. oso aaa 35 10 1 SPECIFICHE ELETTRICHE rile 35 10 2 AMBIENTE OPERATIVO vci iii eee eee nie 35 10 3 TEMPO DI AUTONOMIA IN MINUTI VALORI TIPICI A 25 C 36 10 4 DIMENSIONI E PESI e ia entente nente nets enne tenen 36 11 PORTA DI COMUNICAZIONE 37 11 LUSB glia eene pce 37 11 2 INTERFACCIA RS232 UPS VERSIONE 37 11 3 INTERFACCIA 5400 OPZIONALE iii 37 12 SOFTWARE Lelio 39 APPENDICE PANNELLO POSTERIORE 40 1 Istruzioni di sicurezza e direttiva Si prega di leggere con attenzione il seguente manuale utente e le istruzioni di sicurezza ivi contenute prima dell installazione dell unit oppure nel corso dell uso della stessa 1 1 Installazione Vedere le istruzioni di installazione prima di collegare il dispositivo all alimentazione elettrica possibile che si verifichi la formazione di condensa il gruppo di continuit viene spostato da un ambiente freddo ad uno caldo ll gruppo di continuit deve essere perfettamente asciutto prima della sua installazione Si prega di fornire un periodo di acclimatazione di almeno due ore Non installare il gruppo di continuit vicino all acqua o in un ambiente umido installare il gruppo di continuit in luoghi esposti alla luce solare o
16. protect against shock and impact 1 5 Storage The UPS must be stockpiled in the room where it is ventilated and dry 1 6 Standards Safety IEC EN 62040 1 1 EMI Conducted Emission Category C1 Radiated Emission Category C1 Level 4 Level 3 Level 4 Level 4 Level 3 Level 3 Voltaje Dips Low Frequency Signals 2 Description of Commonly Used Symbols Some or all of the following symbols may be used in this manual It is advisable to familiarize yourself with them and understand their meaning Symbol and Explanation Symbol Explanation Symbol Explanation Alert you to pay special attention Protective ground Caution of high voltage Turn on the UPS Turn off the UPS Ex H L Overload indication Battery Idle or shut down the UPS Recycle Alternating current source AC amp X Do not dispose with ordinary trash Direct current source DC 3 Introduction This On Line Series is an uninterruptible power supply incorporating double converter technology It provides perfect protection specifically for Novell Windows NT and UNIX servers The double converter principle eliminates mains power disturbances A rectifier converts the alternating current from the Socket outlet to direct current This direct current ch
17. stata superata le batterie devono essere sostituite questo caso si prega di contattare il rivenditore 9 2 Stoccaggio Se le batterie vengono stoccate in zone climatiche temperate esse dovrebbero essere ricaricate ogni tre mesi 1 2 ore Si consiglia di effettuare tale operazione ogni due mesi in luoghi soggetti a temperature elevate 9 3 Sostituire le batterie Se la durata della batteria stata superata le batterie devono essere sostituite La sostituzione della batteria deve essere eseguita esclusivamente da personale qualificato Si raccomanda di spegnere completamente l UPS prima della sostituzione Se c un interruttore della batteria spegnerlo prima Staccare il cavo della batteria con attenzione e accertarsi che tutti i cavi esposti non possano essere toccati Ricollegare le nuove batterie al gruppo di continuit come indicato nella sezione 5 8 Quindi accendere l interruttore della batteria e avviare l UPS Se necessario sostituire le batterie mentre l UPS in funzione assicurarsi che il gruppo di continuit non sia spento durante la sostituzione Se c un interruttore della batteria spegnerlo prima Staccare il cavo della batteria con attenzione e accertarsi che tutti i cavi esposti non possano essere toccati Ricollegare le nuove batterie al gruppo di continuit come indicato nella sezione 5 8 Quindi accendere 31 l interruttore della batteria e premere il tasto ON per attivare il gruppo d
18. tr 23 6 8 MODALIT ABIORMALUE laine hte ei t 23 7 IMPOSTAZIONI TRAMITE LCD 24 8 RISOLUZIONE DEI 27 9 MANUTENZIONE aree ea 31 FUNZIONAMENTO Rel ia 31 HE STOGCABSIO omne 31 9 3 SOSTITUIRE DEBATTERIE e d a st bet 31 10 selle 33 10 1 SPECIFICHE 5 et ob ecd ud 33 10 2 AMBIENTE OPERATIVO X 33 10 3 TEMPO DI AUTONOMIA IN MINUTI VALORI TIPICI A 25 34 10 4 DIMENSIONI E PESI S e itp POS tnt dt Ronde Aud 34 11 PORTA DI 4 35 t Reo erede m ER II de ONES 35 11 2 INTERFACCIA RS232 UPS VERSIONE 21 35 11 3 INTERFACCIA AS400 OPZIONALE n 35 12 SOPT WARE 2 37 APPENDICE PANNELLO POSTERIORE 38 1 Safety Instructions Please read carefully the following user manual and the safety instructions before installing the unit or using the unit 1 1 Installation Seeinstallation instructions before
19. wiring socket components inside the UPS are still connected to the battery which are potentially dangerous Before carrying out any kind of service and or maintenance disconnect the batteries Verify that no current is present and no hazardous voltage exists in the capacitor or BUS capacitor terminals Batteries must be replaced only by qualified personnel Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the ground Verify that no voltage is present before servicing Batteries have a high short circuit current and pose a risk of shock Take all precautionary measures specified below and any other measures necessary when working with batteries remove all jewellery wristwatches rings and other metal 3 objects use only tools with insulated grips and handles When changing batteries replace with the same quantity and the same type of batteries Do not attempt to dispose of batteries by burning them It could cause explosion Do not open or destroy batteries Effluent electrolyte can cause injury to the skin and eyes It may be toxic Please replace fuse only by a fuse of the same type and of the same amperage in order to avoid fire hazards Do not dismantle the UPS except the qualified maintenance personnel 1 4 Transport Please transport the UPS only in the original packaging to
20. 10 3 TYPICAL BACKUP TIME TYPICAL VALUES AT 25 C IN MINUTES 33 10 4 DIMENSIONS AND WEIGHTS iii 33 11 COMMUNICATION PORT 1 34 tette ine a ini 34 11 2 RS232 INTERFACE OPTION cei 34 11 3 AS400 INTERFACE OPTION rei 34 12 SOFTWARE RU 36 APPENDIX REAR PANEL 37 1 ISTRUZIONI DI SICUREZZA E DIRETTIVA 1 INSTALLAZIONE i iecit ote eec eee pee ep tte tete iade sedes 1 1 2 FUNZIONAMENTO aede eR reine dauctveredoentes 2 1 3 MANUTENZIONE RIPARAZIONE E GUASTI i 3 1 ATRASPORTO ipuir nana on eens tee 4 TS STOCCAGGIO RR 4 INO Dp 5 2 DESCRIZIONE DEI SIMBOLI D USO COMUNE 5 5 6 4 DESCRIZIONE DEL PANNELLO 7 5 COLLEGAMENTO E FUNZIONAMENTO 11 SCLISPEZIONE ee aee pop 12 25 2 COLLEGAMENTO i opere eec ded ede ee ae 12 5 3 RICARICA DELLA BATTERIA 14 SV ACCENDERETL UPS iioi nic op Pa ER EPOR 15 5 5 PROVA FUNZIONALETE eaves A nte t ae en
21. 12 5 2 CONNECTION reet Ri 12 S S BATTERY 2 14 54 TURN ON THE 0 6 E 15 S S TEST FUNCTION 556 E ERRORI ap EO REESE 15 9 6 TURN OFE THE UPS inen AE NEUE ca sides Fee YEN 15 5 7 AUDIBLE ALARM MUTE FUNCTION 16 5 8 OPERATION PROCEDURE OF EXTERNAL BATTERY FOR LONG BACKUP TIME MODEE S nri DR PII a 16 6 OPERATING MODE FOR ALL MODELS 18 SEINE MODE 4 EP 18 6 2 BATTERY MODE 31010300300 o sachin earache beatae 19 6 3 BYPASS MODE 20 6 4 NO OUTPUT MODE ferente der Er eee 21 6 5 EPO EMERGENCY POWER OFF 22 6 6 ECO MODE ECONOMY enne enne enne nennen nennen ne 22 0 CONVERTER Ie FR dese eve recede ERE 23 6 8 ABNORMAL MODE rete bete eee en eee 23 7 SETTING BY LCD 24 8 TROUBLE 44 4 27 9 MAINTENANCE gZ ia 31 9 TOPERATION IE 31 9 2 STORAGE ME 31 9 3 BATTERY REPLACE nra E RR A AEE 31 TO TECHNICAL DATA 32 10 1 ELECTRICAL SPECIFICATIONS 32 10 2 OPERATING 32
22. DURANTE Specialisti in UPS dal 1980 USER S MANUAL MANUALE UTENTE For Models NL120N 1 3KVA Uninterruptible Power System UNINTERRUPTIBLE POWER SYSTEM 1 1 SAFETY AND INSTRUCTIONS 1 LI INSTALLATION a alla 1 1 2 OPERATIONG ttp te aah het Htec CEDE EC a e lo 2 1 3 MAINTENANCE SERVICING AND FAULTS 3 TAETRANSPOBES oit ella 4 1 5 STORAGE excea DAD iuh dun Aa 4 T STANDARDS sad 4 2 DESCRIPTION OF COMMONLY USED SYMBOLS 6 3 INTRODUCTION 7 4 PANEL DESCRIPTION 8 5 CONNECTION AND OPERATION 12 5T INSPECTIONS o eco fuh oasis ap ae cM rte ce 12 5 2 CONNECTION ollare so 12 CHARGE ooa tax iube bete ea HDD 14 5 4 TURN ON THE UPS a 11cm tic Ee ME 15 5 STESFFUNGION 15 5 6 OFF THE UP S panier 15 5 7 AUDIBLE ALARM MUTE FUNCTION 16 5 8 OPERATION PROCEDURE OF EXTERNAL BATTERY FOR LONG BACKUP TIME MODELS MODEL all 16 6 OPERATING MODE FOR ALL MODELS 18 atea 18 6 2 BATTERY MODE all 19 6 3 BYPASS MOBER illa 20 6 4 MODE lille ica 21 6 5 EPO EMERGENCY POWER OFF asili 22 6 6 ECO MODE ECONOMY MODE
23. GING 5 Hz BATTERY OUTPUT SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF Step 2 The flickering line would move to 230Vac after pressing the Select button two times again V iA CHARGING Hz BATTERY OUTPUT SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF Step 3 The line below 230 would turn to flickerless after pressing the Enter button V Lt pugo A S iHz Hz BATTERY OUTPUT SETTING 50 60 2 208 220 230 240 Vac BYPASS ON OFF Step 4 The output voltage would be 230Vac after the UPS is turned on 26 8 Trouble Shooting If the UPS system does not operate correctly check the operating status on the LCD display Normal operating mode Code No output mode 0 Bypass mode 1 Line mode 2 Battery mode 3 Battery test mode 4 ECO mode 5 Converter mode 6 Warning Code Site fail 09 Fan fail 10 Battery over voltage over charged 11 Battery low 12 Charge fail 13 DC DC temperature high 21 Inverter temperature high 24 Ambient temperature high 25 Line voltage high OVCD action 26 Battery open 27 Overload 29 Fault Code Bus fault 05 Inverter fault 06 Overload fault 07 Over temperature fault 08 Inverter short 14 Bus short 28 27 If the UPS system does not operate correctly please attempt to solve the problem using the table below Problem Possible cause Rem
24. I Ln ca ZI lt rir 2252 lt N CHARGING SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF The No output mode 6 5 EPO Emergency Power Off It is also called RPO Remote Power Off On LCD display the mode code is 0 the word of EPO are presented in the position of output voltage It is a special status in which the UPS would shut the output off and alarm The UPS could not be turned off by pressing OFF button on the panel only after releasing EPO status by plugging in the EPO switch 6 6 ECO mode Economy mode It is also called high efficiency mode In ECO mode on LCD display the mode code is 5 After the UPS is turned on the power used by the load is supplied from the utility power via internal filter while the utility power is in normal range so the high efficiency could be gained in the ECO mode Once the mains is loss or abnormal the UPS would transfer to battery mode and the load is supplied continuously by the battery 22 1 It could be enabled through the LCD setting the software Winpower etc 2 It is attention that the transfer time of UPS output from ECO mode to battery mode is less than 10ms But it is still too long for some sensitive load 6 7 Converter mode In converter mode on LCD display the mode code is 6 The UPS would free run with fixed output frequency 50Hz or 60Hz in converter mode Once the mains is loss or abnormal the UP
25. KS 38 USB EPO Ventole Interruttore INGRESSO SPINA d entrata USB EPO Ventole Interruttore INGRESSO Morsetti d entrata Intelligent Slot schede opzionali Presa Batteria Esterna Prese in uscita Fusibili prese Prese in uscita Protezione Sovratensioni per Rete Fax Modem Intelligent Slot schede opzionali Tai Presa Batteria Esterna Prese in uscita Fusibili prese Prese in uscita Protezione Sovratensioni per Rete Fax Modem A Vista posteriore 3K KS 39 614 03794 00
26. Lu gt ECL CUP quando l utente in modalit di impostazione dell UPS UPS sta per l impostazione della normale modalit online dell inverter modalit normale ECO sta per l impostazione della modalit risparmio energetico CVF sta per l impostazione della modalit di conversione Nella sezione 6 di seguito vengono presentate nel dettaglio le tre modalit operative di impostazione 11 5 Collegamento e funzionamento Il sistema pu essere installato solo da addetti qualificati in conformit con le normative di sicurezza vigenti Nell installazione dei cablaggi elettrici si prega di fare attenzione all amperaggio dell alimentatore 5 1 Ispezione Controllare che non vi siano danni alla confezione ed al suo contenuto Si prega di informare immediatamente l azienda di trasporto in caso di segni di danneggiamento Si prega di tenere da parte la confezione per usi futuri Nota Assicurarsi che la rete di alimentazione sia protetta per evitare che venga riattivata 5 2 Collegamento 1 Collegamento in entrata dell UPS Se l UPS collegato via cavo elettrico si prega di usare una presa adeguata con una protezione anti folgorazione e di prestare attenzione alla tensione della presa Sopra i 9A per 1K S sopra i 17A per 2K S sopra i 26A per 3K S Se l UPS collegato tramite cavo consigliata la scelta di cavi da 2 5mm ed il cavo di terra dovrebbe essere messo a massa usando il
27. S would transfer to battery mode and the load is supplied continuously by the battery 1 It could be enabled through the LCD setting or the software Winpower etc 2 The load should be derating to 6096 in converter mode 6 8 Abnormal mode In abnormal mode such as Bus fault etc the corresponding fault code would be shown to indicate the operating mode of the UPS And some warning words could also be shown for example SHORT would be shown when the load or the UPS output is short and the UPS is in inverter fault mode 23 7 Setting by LCD Module The output voltage and frequency and bypass state and ECO mode and Converter mode could be set directly through LCD module The output voltage could be set to 208V 220V 230V and 240V The output frequency could be set to 50Hz and 60Hz The operating mode of UPS could be set between the Line mode ECO mode and Converter mode The bypass state could be set to enable and disable But all the settings could only be done when the UPS is in bypass or no output mode In bypass or no output mode pressing the Select button on the LCD panel for more than one second a flickering black dot would be shown before 50 2 on the screen And if pressing the Select button continuously again the flickering black dot would move to 6 2 next to 208V 220V 230V 240V Bypass ON Bypass OFF UPS ECO CVF in turn Here UPS mea
28. UPS sta lavorando in modalit batteria DISCHARGING e che la batteria si sta scaricando per alimentare il carico CHARGING Indica che la batteria si sta caricando OVER Indica che la batteria sovraccarica e che l UPS VOLT alla modalit batteria 10 I Indica che la batteria scarica e che l UPS si LOW spegner fra poco Informazioni sullo stato dell UPS Indica lo stato dell UPS un codice di allarme errore o il numero degli UPS che compongono il sistema parallelo codici sono spiegati in dettaglio nel prossimo capitolo Indica che presente un allarme e che UPS sta FAULT funzionando in modalit anomala Indica la presenza di un avvertenza cui WARNING necessario prestare attenzione Informazioni sull impostazione dell UPS Si pu selezionare il valore di tensione in uscita tra i 4 possibili quando l UPS in modalit No 208 220 230 240 Vac Output o By pass pu essere attivo soltanto un urs NE valore alla volta Declassare del 1096 quando la tensione in uscita regolata a 208VAC Si pu selezionare la frequenza della tensione in uscita tra le 2 possibili quando l UPS in modalit No Output o By pass pu essere attivo soltanto un valore alla volta Si pu disabilitare o abilitare la modalit con By BYPASS ON OFF pass quando l UPS in modalit No Output o No By pass pu essere attiva soltanto una delle due 1 Qui diventa invece
29. a di rete di alimentazione perch ci interromperebbe il collegamento a terra del sistema UPS e di tutti i carichi allacciati UPS dotato della sua sorgente di alimentazione interna batterie possibile essere vittime di scossa elettrica quando si tocca la presa dell UPS oppure la morsettiera d uscita anche se il gruppo di continuit non collegato alla rete di alimentazione Per scollegare del tutto l UPS premere prima il pulsante OFF per spegnere l UPS poi scollegare dalla rete il cavo di alimentazione Assicurarsi che nessun liquido o oggetti estranei penetrino nell UPS Non rimuovere il rivestimento La manutenzione di questo sistema deve essere effettuata esclusivamente da personale qualificato Rimuovere il pannello di protezione solo dopo aver disconnesso la morsettiera Usare cavo di rame 12 AWG come cavo d ingresso dei 2 rame 90 e 4 4 Ib in forza di torsione Usare un filo di rame 10 AWG per i cavi di connessione agli armadi batteria rame 90 e 12 Ib in forza di torsione 1 3 Manutenzione riparazione e guasti L UPS funziona con tensioni pericolose La manutenzione e le riparazioni possono essere effettuate solo da personale qualificato Attenzione pericolo di folgorazione Anche dopo avere scollegato l unit dalla rete di alimentazione presa di rete domestica i componenti all interno dell UPS rimangono connessi alla batteria e sono pertant
30. annoying in bypass mode you may press OFF button continuously for more than 1 second to clear it The action doesn t affect the warning and fault alarm 5 8 Operation procedure of external battery for long backup time model S model 1 Use the battery pack with voltage 36VDC for NL120N 1K KS 3 pcs of 12V batteries 96VDC for NL120N 2K KS 3K KS 8 pcs of 12V batteries Connection of batteries more than or less than required will cause abnormality or permanent damage 2 One hard wiring type battery terminal on the rear panel is used for connecting the battery pack 3 The battery connection procedure is very important Any incompliance may result in the risk of electric shock Therefore the following steps must be strictly complied with 4 Make sure the mains input is cut off if there is a battery breaker then turn it off first 5 Remove the small cover of terminal block prepare the battery cable which should be able to carry the current of 230A for NL120N 1KVA 222A for NL120N 2KVA gt 33A for NL120N 3KVA the cross section area should be great than 4 mm for all model And battery wire color is recommended as following 16 GND Red wire Green Yellow wire Black wire 6 The red wire is connected to the terminal of the battery The black wire is connected to the terminal of the battery Note the green yellow wire is grounded for protection purpose 7 Make sure the wires
31. arges the batteries and powers the inverter On the basis of this DC voltage the inverter generates a sinusoidal AC voltage which permanently supplies the loads Computers and periphery are thus powered entirely by the mains voltage In the event of power failure the maintenance free batteries power the inverter This manual covers the UPS listed as follows Please confirm whether it is the model you intend to purchase by performing a visual inspection of the Model No on the rear panel of the UPS Model No Type Model No Type NL120N 1K NL120N 1K KS ml Z Extended NL120N 2K Standard NL120N 2K KS backup time NL120N 3K NL120N 3K KS KS Model Extended backup time 4 Panel Description Select Button OVER WARNINGFAULT 88 OVER NN VOLT LOAD Low E mm ERROR ES SHORT I LCD Screen 888v 888v 888v 888A 888A 888A DISCHARGING 88Hz 88Hz SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF ON Button C anc ad Alarm Silence Enter Button OFF Button The Display Panel Switch Function ON Button Turn on UPS system By pressing the ON Button the UPS system is turned on Deactivate acoustic alarm By pressing this Button an acoustic alarm can be deactivated in the battery mode Do the battery test By pressing this Button the UPS can do the battery test in the Line mode or ECO mode or Convert
32. carico al pi presto Se l allarme in modalit By pass troppo fastidioso possibile tenere premuto il tasto OFF per di un secondo per rimuoverlo Questa azione non avr influenza sull allarme di avvertenza e di guasto 5 8 Procedura operativa della batteria esterna per i modelli a lunga autonomia modello KS 1 Usare batterie con tensione 36VDC per 1KS 3 pz batterie a 12V 96VDC per 2KS 3KS 8 pz batterie a 12V Il collegamento di batterie a tensione superiore o inferiore causer anormalit di funzionamento o danni permanenti 2 Sul pannello posteriore viene usata una morsettiera per il collegamento al gruppo batterie 3 La procedura di collegamento della batteria molto importante Qualsiasi non conformit pu dar luogo al rischio di folgorazione quindi necessario attenersi strettamente alle fasi seguenti 4 Assicurarsi che il collegamento alla rete elettrica sia staccato se esiste un interruttore della batteria necessario spegnere prima questo ultimo 5 Rimuovere la piccola copertura della morsettiera preparare il cavo della batteria che dovrebbe essere in grado di supportare corrente 230A per 1KVA 222A 2KVA gt 33A per 3KVA la sezione trasversale dei cavi dovrebbe essere superiore a 4 mm 16 per tutti i modelli consigliato l uso seguente riguardo al colore del filo della batteria A terra rosso Filo verde giallo Filo nero 6 Il f
33. ccur in the UPS fault code or warning code could be displayed and the codes are illuminated in detail in the following chapter 10 FAULT Indicates the UPS is working in fault mode Indicates some warnings occur which need be attention UPS setting Information The four value of the output voltage could be selected when the UPS is in No output or Bypass mode and only one of them could be active in the same time Derating 1096 when the output voltage is adjusted to 208VAC The two frequency value of the output voltage could be selected when the UPS is in No output or Bypass mode and only one of them could be active in the same time Bypass disable or enable could be selected when the UPS is in No output or Bypass mode and only one of them could be active in the same time RI res 1 Here would become Li 8 instead when the user does operating mode of UPS setting UPS means the setting of normal inverter mode Line mode ECO means the setting of economy mode CVF means the setting of converter mode The detail illustration of the three modes and the operation of the setting would be presented in the following section 6 11 5 Connection and Operation The system may be installed and wired only by qualified electricians accordance with applicable safety When installing the electrical wiring please note the nominal amperage of your incoming feeder 5 1 Inspec
34. e l interruttore EPO Guasto al Bus Guasto interno all UPS Darne notifica al fornitore Guasto dell inverter Guasto interno all UPS Darne notifica al fornitore Errore di sovra temperatura Sovra temperatura Controllare la ventilazione dell UPS la temperatura e la ventilazione ambiente Corto circuito dell inverter Corto circuito dell uscita Rimuovere tutte i carichi Spegnere l UPS Controllare se l uscita dell UPS e i carichi siano in corto circuito Assicurarsi che il corto circuito venga rimosso e il gruppo di continuit non abbia difetti interni prima di accenderlo di nuovo Corto circuito al Bus Guasto interno all UPS Darne notifica al fornitore 29 Si prega avere le seguenti informazioni portata di mano prima di chiamare il Dipartimento Post Vendita Numero modello numero seriale Data nella quale si verificato il problema Stato del display stato del cicalino di allarme gt Condizione dell alimentazione elettrica tipo di carica e capacit temperatura ambiente condizione della ventilazione 5 L informazione quantit e capacit batteria del gruppo batteria esterno se il modello dell UPS S 6 Altre informazioni per la descrizione completa del problema 30 9 Manutenzione 9 1 Funzionamento L UPS non contiene parti riparabili dall utente Se la durata della batteria 3 5 anni a 25 C temperatura ambiente
35. edy No indication no warning tone even though system is connected to mains power supply No input voltage Check building wiring Socket outlet and input cable Display code 1 in Inverter not Press On Switch LCD even though switched on the power supply is available Display code 3 in Mains power Switching to battery mode LCD and audible alarm sounding every 1 beep in every 4 seconds supply has failed or Input power and or frequency are out of tolerance automatically Check input power source and inform dealer if necessary Emergency supply period shorter than nominal value Batteries not fully charged batteries defect Charge the batteries for at least 5 8 hours and then check capacity If the problem still persists consult your dealer Fan fail Fan abnormal Check if the fan is running Battery over voltage Battery is over charged Switching to battery mode automatically and after the battery voltage is normal and the mains is normal the UPS would Switching to line mode automatically again Battery low Battery voltage is When audible alarm low sounding every second battery is almost empty Charge fail The charge is Notify dealer broken DC DC temperature high Inside temperature of the UPS is too high Check the ventilation of the UPS check the ambient temperature Inverter temperature high Inside temperatu
36. eggiante smette di lampeggiare e la tensione di uscita o di frequenza lo stato di by pass o la modalit di stato di impostazione verranno modificate secondo il valore selezionato Se non viene tenuto premuto il tasto Select o Enter per oltre 30 secondi la linea nera lampeggiante sparir valori di tensione selezionabili sono 208V 220V 230V 240V valori di frequenza selezionabili sono 50Hz 60Hz La tensione e la frequenza in uscita verranno applicate in base al valore corrispondente scelto dopo che l UPS verr acceso mediante la pressione del pulsante ON L UPS passer in modalit By pass alcuni secondi dopo aver premuto il pulsante By pass ON e in modalit No Output alcuni secondi dopo aver premuto il pulsante By pass OFF Il cambio della modalit diventer attivo solo dopo l accensione dell UPS 24 m Qui di seguito riportato mo di esempio come cambiare la tensione in uscita da 220V a 230V tramite il pannello LCD xi EX V A CHARGING Hz BATTERY OUTPUT SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF Fase 1 Dopo aver premuto il pulsante Select tre volte sotto la scritta 208 comparir una linea nera lampeggiante CHARGING 50 60 2 208 220 230 240 55 Fase 2 Premere il pulsante Select per altre due volte la linea lampeggiante si sposte
37. ella batteria bassa Il caricabatterie rotto La temperatura interna dell UPS troppo elevata Quando l allarme acustico suona ogni secondo la batteria quasi scarica Darne notifica al fornitore Controllare la ventilazione dell UPS e la temperatura ambiente Elevata temperatura La temperatura interna Controllare la ventilazione 28 dell inverter Elevata temperatura ambiente dell UPS troppo elevata La temperatura ambiente troppo elevata dell UPS e la temperatura ambiente Controllare la ventilazione dell ambiente Tensione rete elevata azione OVCD La tensione in entrata troppo elevata Passaggio automatico alla modalit batteria e dopo che la corrente torner alla norma l UPS torner di nuovo alla modalit normale Batteria aperta Sovraccarico Il gruppo batteria non collegato in maniera corretta Sovraccarico Effettuare il test batteria per darne conferma Controllare che il gruppo batteria sia collegato all UPS Controllare che l interruttore della batteria sia acceso Controllare i carichi e rimuovere alcuni carichi non critici Controllare se alcuni Sono guasti carichi Guasto locale conduttore di fase quello neutrale a all ingresso dell UPS sono invertiti Ruotare la presa di corrente di 180 gradi oppure ricollegare il sistema UPS EPO attivo La funzione EPO abilitata Innestar
38. er mode OFF Button When mains power is normal the UPS system switches to No output or Bypass mode by pressing OFF Button and the inverter is off At this moment if Bypass is enabled then the output sockets are supplied with voltage via the bypass if the mains power is available Deactivate acoustic alarm By pressing this Button an acoustic alarm can be deactivated in the bypass mode Select Button Enter Button If the UPS system is No output or Bypass mode the output voltage and frequency and Bypass disable enable and operating mode could be selected by pressing Select Button and confirmed by pressing Enter Button UPS Status Battery Information Information Load Information 88 888 888 SESA BEBA 1888 DISCHARGING BHBHz i BBHz SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF UPS Setting Input Information Output Information The LCD Display Display Function Input Information Indicates the input Line voltage value which could H V be displayed from 0 to 999Vac oc H Indicates the frequency value of input Line 2 voltage which could be displayed from 0 to 99Hz Bn A Indicates the input Line current value which could QR be displayed from 0 to 99 9A Output Information Indicates the UPS output voltage value which B HB V could be displayed from 0 to 999Vac D
39. formazioni in ingresso a Indica il valore in volt della tensione della rete di ba H V alimentazione in ingresso da 0 a 999Vac em Indicata il valore di frequenza della corrente in S Hz i ingresso da 0 99 2 Indica il valore in ampere della corrente in ingresso da 0 a 99 94 Informazioni in uscita Indica il valore in volt della tensione in uscita dall UPS da 0 a 999Vac Ga Hz Indica il valore di frequenza della tensione e della corrente in uscita dall UPS da 0 a 99Hz cao A Indica il valore in ampere della corrente in uscita dall UPS da 0 a 99 9 Informazioni di carico Indica che il carico in uscita dell UPS in SHORT cortocircuito e l UPS sta per spegnersi OVER Indica che il carico eccede la potenza nominale LOAD indicata nelle specifiche Indica la percentuale di carico la tacca pi bassa indica carico del 30 due tacche partendo dal basso il 60 3 tacche il 90 tutte le tacche il 100 Informazioni sulla batteria m c Indica il valore in volt della tensione della batteria B V da 0 a 999Vdc m Indica il valore in ampere della corrente di batteria BRA d da 0 a 99 9 Indica la percentuale di capacita della batteria ogni tacca rappresenta una capacit del 25 Se sono visualizzate tutte le tacche la E capacit del 100 Indica che l
40. i continuit fare il test delle batterie controllare che le informazioni sulla batteria siano nella norma 32 10 Dati tecnici 10 1 Specifiche elettriche INGRESSO Modello 1K 1K KS 2K 2K KS 3K 3K KS Fase MonoFase Frequenza 45 55 54 66 Hz Corrente 9A 17A 26A USCITA Modello 1K 1K KS 2K 2K KS 3K 3K KS Potenza 1kVA 0 8kW 2kVA 1 6kW 3kVA 2 4kW Tensione 208 220 230 240x 43 296 Frequenza 50 60 0 2 Hz modalit batteria Forma sinusoidale dell onda Declassare al 90 quando la tensione d uscita regolata a 208VAC BATTERIE N Modello 1K 2K 3K Numero e tipo 3x12V 7Ah 8x12V 7Ah 8x12V 7Ah 10 2 Ambiente operativo Temperatura ambiente 0745 C Umidit lt 95 Altitudine lt 1000m Temperatura di 0 45 C stoccaggio 33 10 3 Tempo di autonomia in minuti Valori tipici 25 C N Modello 100 carica 50 carica 1K 5 14 2K 9 21 3K 5 15 10 4 Dimensioni e pesi TT Dimensioni WxDxH mm Peso netto kg 1K 145x400x220 13 1K KS 145x400x220 7 2K 192x460x347 31 2K KS 192x460x347 13 3K 192 460 347 31 3K KS 192x460x347 13 34 11 Porta di comunicazione La porta di comunicazione serve per il software di monitoraggio In dotazione ci sono una porta USB e una slot 11 1 USB La porta USB in conformit con il protoc
41. il personale qualificato addetto alla manutenzione autorizzato a effettuare tale operazione 1 4 Trasporto Usare esclusivamente l imballaggio originale per trasportare l UPS onde proteggerlo da urti e impatti 1 5 LUPS deve essere immagazzinato un locale e asciutto 1 6 Standard Sicurezza IEC EN 62040 1 1 EMI Emissioni condotte Categoria C1 Emissioni irradiate Categoria C1 Corrente armonica Fluttuazioni di tensione e flicker EMS Livello 4 Livello 3 Livello 4 Livello 4 Livello 3 Livello 3 2 Descrizione dei simboli d uso comune simboli seguenti si possono incontrare tutti o in parte nel presente manuale consigliabile imparare a conoscerli e a capirne il significato Simbolo e spiegazione spiegazione spiegazione Prestare particolare Terra di protezione attenzione Rischio di Tacitazione allarme folgorazione acustico Accensione UPS Spegnimento UPS Batteria Spegnimento o disattivazione UPS Presa corrente X Non smaltire nei alternata AC rifiuti ordinari Presa corrente continua DC Riciclaggio 3 Introduzione Questo gruppo di continuit tipologia Online incorpora la tecnologia a doppia conversione e offre una protezione totale specifica per Novell Windows NT e server UNIX Grazie al principio del doppio convertitore si eliminano tutti i dis
42. ilo rosso collegato al terminale della batteria Il filo nero collegato al terminale della batteria Nota Il verde giallo messo a terra a scopo protettivo 7 Assicurarsi che i fili siano fissati installare la copertura della 8 morsettiera sul pannello posteriore dell UPS Collegare PUPS al carico Accendere poi l interruttore di alimentazione oppure collegare il filo della corrente dell UPS alla rete e la batteria inizier ad essere ricaricata Avvertenza Un interruttore DC deve essere collegato tra l UPS e batteria esterna Avvertenza Nelle prese di uscita del sistema UPS pu essere presente tensione elettrica anche se il sistema di alimentazione stato scollegato o l interruttore di by pass in posizione Interruttore DC N Modello TENSIONE CORRENTE 1K KS 48Vac 50A 2K KS 125Vdc 40A 3K KS 125Vdc 60A 17 6 Modalit operative tutti i modelli vari codici che possono comparire sul display LCD corrispondono alle rispettive modalit operative e sono indicati nella tabella seguente Viene indicato in ogni momento solo una modalit operativa normale oppure una modalit di errore Ma possono comparire anche diverse avvertenze in una determinata modalit operativa normale alla volta codice della modalit operativa normale e il codice di avvertenza dovrebbero essere indicate in circolo Una volta che interviene un alla
43. l pulsante ON il sistema UPS si accende Per disattivare l allarme acustico Un allarme acustico pu essere disattivato in modalit batteria premendo Pulsante ON questo pulsante Effettuare il test sulla batteria Premendo questo pulsante l UPS in grado di effettuare il test sulla batteria nella modalit normale in modalit ECO oppure in modalit convertitore Pulsante OFF Quando l alimentazione di rete funziona normalmente il sistema UPS passa alla modalit No Output o alla modalit By pass premendo il pulsante OFF e l inverter disattivo Se il by pass abilitato attraverso questo che vengono alimentate le prese d uscita sempre se l alimentazione di rete disponibile Per disattivare l allarme acustico Un allarme acustico pu essere disattivato in modalit by pass premendo questo pulsante Se il sistema UPS in modalit No Output By pass premendo il pulsante PulsanteSelect Select e confermando la scelta col tasto Enter si possono selezionare la tensione in uscita la frequenza e la possibilit di disattivare abilitare il by PulsanteEnter pass UPS Status Battery Information Information Load Information OVER WARNINGFAULT OVER VOLT iLOAD E3 SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF UPS Setting Input Information Output Information Il display LCD Display Funzione In
44. ll UPS stesso Nota L impostazione di default per la modalit By pass e No output dopo il collegamento dell UPS alla rete di alimentazione e all accensione dell interruttore Questo essere configurato attraverso il monitoraggio del pannello LCD o del firmware l impostazione di fabbrica per la modalit di By pass e abilitata per 5 5 Prova funzionalit Provare la funzionalit dell UPS tenendo premuto l interruttore ON per pi di un secondo esso rilever se la batteria collegata oppure scarica L UPS anche in grado di effettuare prove in maniera automatica e periodica il tempo pu essere impostato dall utente 5 6 Spegnere l UPS 1 In modalit inverter Tenere premuto il tasto OFF in maniera continuata per pi di un secondo per spegnere l UPS esso entrer in modalit No output oppure By pass A questo punto questo punto PUPS dovrebbe avere tensione in uscita se abilitata la funz By pass Scollegare la rete di alimentazione per terminare l uscita 15 2 In modalit batteria Tenere premuto il tasto OFF in maniera continuata per pi di un secondo per spegnere l UPS esso si spegner in maniera completa 5 7 Funzione allarme acustico muto Se l allarme in modalit batteria troppo fastidioso possibile tenere premuto il tasto ON per di un secondo per rimuoverlo Inoltre l allarme verr abilitato quando la batteria scarica per ricordarvi di spegnere il
45. minutes Model No 100 Load 50 Load NL120N 1K 5 14 NL120N 2K 9 21 NL120N 3K 5 15 10 4 Dimensions and weights Model No Dimensions WxDxH mm a NL120N 1K 145x400x220 13 NL120N 1K KS 145x400x220 7 NL120N 2K 192x460x347 31 NL120N 2K KS 192x460x347 13 NL120N 3K 192x460x347 31 NL120N 3K KS 192x460x347 13 33 11 Communication Port The communication port is for the monitoring software A USB port and an intelligent slot are provided 11 1 USB The USB port is compliance with USB 1 1 protocol 11 2 RS232 Interface Option The following is the pin assignment and description of DB 9 connector Description y o TXD Output RXD Input 11 3 AS400 Interface Option Except for the communication protocol as mentioned above this series UPS has AS400 card an optional accessory for AS400 communication protocol Please contact your local distributor for details The following is the pin assignment and description of DB 9 connector in AS400 card Pin Description Pin Description 1 0 1 UPS Fail Output 6 Bypass Output 2 Summary Alarm Output 7 Battery Low Output 3 GND Input 8 UPS ON Output 4 a Input 9 Line Loss Output 5 Common Input 34 1 UPSFAIL i 9 BYPASS SUMMARY ALARM BATTERY LOW o gt GND UPS ON REMOTE SHUTDOWN o4 LINE FAIL
46. ng wiring installation Please see the disconnect device specification in chapter 5 2 Equipment the powered more than one source 1 2 Operation Do not disconnect the mains cable on the UPS or the building wiring socket grounded shockproof socket during operation as this would remove the ground to the UPS and of all connected loads The UPS features its own internal current source batteries You may be electric shock when you touch the UPS output Sockets or output terminal block even if the UPS is not connected to the building wiring socket In order to fully disconnect the UPS first press the OFF button to turn off the UPS then disconnect the mains lead Ensure that no liquid or other foreign objects can enter the 2 UPS Do not remove the enclosure This system is to be serviced by qualified service personnel only Remove the protective panel only after disconnecting the terminal connections Use No 12 AWG for 2 3K KS input wire 90 copper wire and 4 4 Ib in Torque force when connecting to terminal block Use No 10AWG all models battery wire 90 copper wire 12 Torque force when connecting to terminal block 1 3 Maintenance servicing and faults The UPS operates with hazardous voltages Repairs may be carried out only by qualified maintenance personnel Caution risk of electric shock Even after the unit is disconnected from the mains power supply building
47. ns the normal inverter mode and UPS ECO would be presented circularly at the position of output current And if pressing the Enter button for more than one second at this time the flickering black dot would turn to flickerless and the output voltage or frequency or bypass state or mode state setting would be modified to the selected value And if no any pressing on the Select or Enter button lasting for more than 30 seconds the flickering black dot would disappear The only one voltage value could be selected in 208V 220V 230V 240V at any time The only one frequency value could be selected in 50Hz 60Hz at any time And the output voltage and frequency would be changed to the corresponding value after the right values are selected on the LCD panel and the UPS is turn on by pressing the ON Button The UPS would turn to bypass mode in several seconds after Bypass ON is selected and turn to no output mode in several seconds after Bypass OFF is selected The mode change would be active only after the UPS is turned on 24 Here is a example for changing the output voltage from 220Vac to 230Vac through the LCD panel V Hz CHARGING BATTERY OUTPUT SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF Step 1 One flickering black line would appear before 208Vac after pressing the Select button three times 22 CHAR
48. o posteriore Una volta che il connettore viene aperto l UPS arrester l uscita fino a che lo stato EPO non venga disabilitato Spegnere e riavviare l UPS per ritornare alla modalit normale Abilitare lo stato EPO Disabilitare lo stato EPO 4 Collegamento Tvss Collegare rete fax modem al Tvss proteggerli dalle sovratensioni Tvss 5 3 Ricarica della batteria Ricaricare completamente le batterie del sistema UPS lasciando l UPS collegato all alimentazione elettrica per 1 2 ore possibile utilizzare il sistema UPS direttamente senza ricaricarlo ma la durata dell energia immagazzinata potrebbe essere inferiore al valore nominale specificato 5 4 Accendere l UPS 1 Con collegamento alla rete di alimentazione Premere il pulsante I in maniera continuata per accendere l UPS 14 esso in modalit inverter e il display LCD indicher lo stato dell UPS stesso 2 Senza collegamento alla rete di alimentazione Se l UPS avviamento a freddo senza collegamento all alimentazione di rete l utente deve premere il tasto I due volte la prima pressione del tasto I per dare corrente all UPS e la seconda pressione del tasto I in maniera continuata per pi di 1 secondo serve ad accendere l UPS il gruppo di continuit entrer in modalit inverter Infatti la doppia spinta del tasto I assicura ulteriormente all utente l accensione dell UPS il display LCD indicher lo stato de
49. o potenzialmente pericolosi Prima di effettuare qualsiasi tipo di riparazione e o manutenzione scollegare le batterie Verificare che non sia presente tensione e che non vi sia una tensione pericolosa nei condensatori del BUS di continua Le batterie devono essere sostituite solo da personale qualificato Attenzione pericolo di folgorazione Il circuito della batteria non isolato dalla tensione in entrata Possono essere presenti tensioni pericolose tra i terminali della batteria e la messa a terra Verificare che non ci sia presenza di tensione prima di effettuare le riparazioni Le batterie presentano un elevata corrente di cortocircuito e possono causare scosse Adottare tutte le misure precauzionali specificate qui di seguito e tutti gli altri provvedimenti necessari nel caso in cui si lavori con le batterie non indossare gioielli orologi da polso anelli e altri oggetti metallici servirsi solo di attrezzi con impugnature e manici isolati Quando occorre rimpiazzare le batterie con lo stesso numero e lo stesso tipo di esemplari Non gettare le batterie nel fuoco per evitare il rischio di esplosioni Non aprire n distruggere le batterie L elettrolita che ne fuoriesce pu causare danni alla pelle e agli occhi pu essere tossico Sostituire il fusibile solo con un altro fusibile dello stesso tipo e dello stesso amperaggio per evitare rischi di incendio Non smontare l UPS Solo
50. ollo USB 1 1 11 2 Interfaccia RS232 UPS versione opzionale Di seguito riportata l assegnazione dei pin e la descrizione del connettore DB 9 Description E U TXD Uscita RXD Ground 11 3 Interfaccia AS400 Opzionale Entrata Entrata Fatta eccezione per il protocollo di comunicazione come si detto questa serie UPS ha una scheda AS400 accessorio opzionale per il protocollo di comunicazione AS400 Si prega di contattare il distributore locale per ulteriori dettagli Di seguito riportata l assegnazione dei pin e la descrizione del connettore DB 9 nella scheda di AS400 Descrizione E U Pin Z Descrizione E U 1 Guasto UPS Uscita 6 By pass Uscita 2 Allarme Uscita 7 Batteria bassa Uscita generale 3 GND Entrata 8 UPS ON Uscita Shutdown Mancanza 4 arresto da Entrata 9 Uscita Rete remoto 5 Comune Entrata 35 2 Guasto UPS Allarme generale Batteria bassa GND Shutdown arresto remoto Mancanza Rete Comune Interfaccia DB 9 del protocollo di comunicazione AS400 36 12 Software Download gratuito del software WinPower WinPower un nuovo software di monitoraggio UPS che fornisce un interfaccia facile da usare per monitorare e controllare il proprio UPS Questo straordinario software permette di effettuare in tutta sicurezza lo spegnimento automatico dei sistemi multicomputer in caso di interruzione
51. on Input Socket USB Intelligent Slot EPO External Battery Socket For S Model Only Cooling Fan Output Socket Breaker Output Socket Input Socket Network Fax Modem Surge Protection Back View of NL120N 2K and 2K KS 37 USB Intelligent Slot EPO External Battery Socket For S Model Only Cooling Fan Output Socket Fuse Breaker Output Socket Input Socket Network Fax Modem Surge Protection USB Intelligent Slot EPO External Battery Socket For S Model Only Cooling Fan Output Socket Fuse Breaker Output Socket Input terminal Network Fax Modem Surge Protection Back View of NL120N 3K KS 38 39 DURANTE n MANUALE UTENTE ONLINE UPS Modelli NL120N 1 3kVA 208 220 230 240 Vac Gruppo di continuit UPS INDICE 1 2 3 4 5 SAFETY AND EMC INSTRUCTIONS 1 1 1 INSTALLATION EE T 1 1 2 OPERATION cerent tetti t rh pee rie eee e Ne 2 1 3 MAINTENANCE SERVICING AND FAULTS eee enne nnne 3 1 4 TRANSPORT a edicere erede e aea eeepc 4 TS STORAGE supra ioni o 4 1 0 STANDARDS ehe 5 DESCRIPTION OF COMMONLY USED SYMBOLS 6 INTRODUCTION 7 PANEL DESCRIPTION a rende 8 CONNECTION AND OPERATION 12 Si L INSPECTION noir REALE iii
52. ond is for UPS to turns on the UPS will get into the inverter mode In fact the two pushing I button is to make further sure user operation for turning on UPS the LCD screen will indicate the state of the UPS Note The default setting for bypass mode is no output after UPS is connecting utility power and breaker is turned on This can be configured by monitoring the LCD panel or firmware the out of factory setting for bypass mode is enable for the UPS 5 5 Test function Test the function of the UPS system by pressing the On Switch for more than 1 second the UPS would detect whether the battery is connected or the battery is low And the UPS could also do the test automatically and periodically the period time could be set by user 5 6 Turn off the UPS 1 In Inverter Mode Press OFF button continuously for more than 1 second to turn off the UPS the UPS will get into no output or bypass mode At this time the UPS might has output if bypass is enabled 15 Disconnect the utility power to turn off the output 2 In Battery Mode Press OFF button continuously for more than 1 second to turn off the UPS the UPS will be turned off completely 5 7 Audible alarm mute function If the alarm is too annoying in battery mode you may press ON button continuously for more than 1 second to clear it Moreover the alarm will be enabled when the battery is low to remind you to shutdown the load soon If the alarm is too
53. onds If the ON button on the front panel is pressed for more than 1 second again the buzzer will stop beeping in silence mode Press the button once again for more than 1 second to resume the alarm function 9 nu Li nu Mu 2 ZI na ZI gt lt V uv A A DISCHARGING H BATTERY A OUTPUT SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF 2 The Battery mode 6 3 Bypass mode The LCD display in bypass mode is shown in the following diagram The information about the utility power the battery the UPS output and the load could be displayed The UPS will beep once every 2 minutes in bypass mode The 1 code indicate the UPS is working in the bypass mode 20 B ru ru ru ru Vu nit V V 5 tH H N ni CHARGING BATTERY SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF 2 OUTPUT The Bypass mode The UPS does not have the backup function when it is in bypass mode The power used by the load is supplied from the utility power via internal filter 6 4 NO output mode The LCD display in No output mode is shown in the following diagram The information about the utility power the battery the UPS output and the load could be displayed The 0 code indicates the UPS is working in the No output mode 21 ru nu ru cu 1 Ld lt Z
54. power cord to the output sockets to complete connection Use one cord for every 10A load Model No Output Socket pcs NL120N 1K 1K KS 3 socket IEC 10A NL120N 2K 2K KS 4socket IEC 10A 1pcs 16A NL120N 3K 3K KS 4socket IEC 10A 1pcs 16A Caution Do not connect equipment which would overload the UPS system e g laser printers 13 3 EPO Connection The EPO is NC NC Normally the EPO connector is closed with a wire on the rear panel Once the connector is open the UPS would stop the output until the EPO status is disabled Enable the EPO status Disable the EPO status 4 Tvss Connection Connect Network Fax Modem to Tvss to protect it from Surge 5 3 Battery charge Fully charge the batteries of the UPS system by leaving the UPS system connected to the mains for 1 2 hours You may use the UPS system directly without charging it but the stored energy time may be shorter than the nominal value specified 14 5 4 Turn on UPS 1 With utility power connecting Press 4 button continuously for more than 1 second to turn on the UPS the UPS will get into the inverter mode the LCD screen will indicate the state of the UPS 2 Without utility power connecting If UPS is cold start without utility power connecting user need to push twice first pushing I button is for UPS to get power and second pushing 4 button continuously for more than 1 sec
55. r sotto 230Vac 25 V LA CHARGING Hz SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF Fase 3 Dopo aver premuto il pulsante Enter la linea sotto 230Vac smetter di lampeggiare iV A i Hz SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF Fase 4 La tensione in uscita passer a 230Vac dopo l accensione dell UPS 26 8 Risoluzione dei problemi Se il dispositivo UPS non funziona in maniera corretta controllare lo stato di funzionamento sul display LCD Modalit operativa normale Codice Modalit Uscita OFF 0 Modalit By pass 1 Modalit normale 2 Modalit batteria 3 Modalit test batteria 4 Modalit ECO 5 Modalit conversione 6 Avvertenza Codice Errato collegamento Neutro o mancanza Terra 09 Guasto alla ventola 10 Batteria in sovratensione sovraccarica 11 Batteria bassa 12 Guasto al caricabatterie 13 Elevata temperatura DC DC 21 Elevata temperatura dell inverter 24 Elevata temperatura ambiente 25 Tensione di rete elevata azione OVCD 26 Batteria aperta 27 Sovraccarico 29 Errore Codice Guasto al Bus DC 05 Guasto dell inverter 06 Sovraccarico 07 Sovra temperatura 08 Corto circuito dell inverter 14 Corto circuito al Bus 28 27 Se il dispositivo UPS non funziona in maniera corretta si prega di tentare di risolvere il problema usando la tabella sottostante Problema
56. re of the UPS is too high Check the ventilation of the UPS check the ambient temperature 28 Ambient temperature high The ambient temperature is too high Check the environment ventilation Line voltage high OVCD action Input power voltage is too high Switching to battery mode automatically and after the mains is normal the UPS would Switching to line mode automatically again Battery open Battery pack is not Do the battery test to connected confirm correctly Check the battery bank is connected to the UPS Check the battery breaker is turn on Overload Overload Check the loads and remove some non critical loads Check whether some loads are failed Site fail Phase and neutral Rotate mains power socket conductor at input by 180 or connect UPS of UPS system are system reversed EPO active EPO function is Plug in the EPO switch enabled Bus fault UPS internal fault Notify dealer Inverter fault UPS internal fault Notify dealer Over temperature fault Over temperature Check the ventilation of the UPS check the ambient temperature and ventilation Inverter short Output short circuit Remove all the loads Turn off the UPS Check whether the output of UPS and loads is short circuit Make sure the short circuit is removed and the UPS has no internal faults before turning on again Bus short UPS internal fault
57. rme tutte le precedenti avvertenze non saranno mostrate di nuovo ma verr indicato un solo codice di allarme Modalit operativa normale Codice Modalit No output 0 Modalit By pass Modalit normale Modalit batteria Modalit test batteria Modalit ECO Modalit conversione O Oc 1 o NN gt 6 1 Modalit normale Il display LCD in modalit normale viene mostrato nel diagramma sottostante Sono visualizzati i dati relativi all alimentazione alla batteria al carico e all uscita dell UPS Il codice 2 indica che UPS sta lavorando in modalit normale 18 ru 22 gt lt c iz gt lt m LL 1 TU CHARGING BATTERY Sg MAINS RR OUTPUT SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF N La La modalit normale Se l uscita sovraccarica verr mostrato il messaggio OVERLOAD e l UPS emetter un segnale acustico due volte al secondo Occorre in tal caso eliminare i carichi superflui uno alla volta per ridurre il carico collegato in uscita all UPS al di sotto del 9096 della sua capacit di alimentazione nominale Nota Si prega di seguire queste istruzioni per connettere il generatore e Attivare il generatore e aspettare fino a quando il funzionamento non si stabilizzato prima di far alimentare l UPS accertarsi che l UPS sia in modalit inattiva Successivamen
58. t d t E RR eid ti 15 5 6 SPEGNEREL UPS 15 5 7 FUNZIONE ALLARME ACUSTICO MUTO 16 5 8 PROCEDURA OPERATIVA DELLA BATTERIA ESTERNA PER I MODELLI A LUNGA AUTONOMIA MODELLO 16 6 MODALITA OPERATIVE PER TUTTI I MODELLI 19 6 1 MODALIT NORMALE ccsccescesscessceecesecsecnsecssecseecaeeeneceneeeneeesesneneeesseneenaes 19 0 2 MODALITA BATTERIA sii iieri tto eee enm E rst sass 20 6 3 MODALIT BY PASS cirie ieri eee 21 6 4 MODALIT NO OUTPUT L 22 6 5 MODALIT EPO EMERGENCY POWER OFF i 23 6 6 MODALIT ECO MODALIT A RISPARMIO ENERGETICO 23 6 7 MODALIT CONVERSIONE 2 2 2404 8 0000000000000000000000000000000000000000 24 6 8 MODALIT ANORMALE ci 24 7 IMPOSTAZIONI TRAMITE MODULO LCD 25 8 RISOLUZIONE DEI 29 9 4 4020 2 2222 2 11 33 97 BUNZIONAMENTO certet ree REO PE ARRE SERE 33 P RSILO ee Ye eo 33 973 SOSTITUIRE LE BATTERIE peo rr ree ariete 33 10 DATI TECNICI nets
59. te accendere l UPS seguendo la procedura di avvio Dopo aver acceso l UPS si possono connettere ad esso i carichi una alla volta La potenza del generatore AC deve essere almeno doppia rispetto alla potenza dell UPS 6 2 Modalit batteria Il display LCD in modalit batteria mostrato nel diagramma sottostante Sono visualizzati i dati relativi all alimentazione alla batteria al carico e all uscita del UPS Il codice 3 indica che l UPS 19 sta lavorando in modalit batteria Quando l UPS in modalit batteria l allarme acustico suona ogni 4 secondi Se si tiene premuto il pulsante ON sul pannello frontale per di 1 secondo l allarme smetter di suonare modalit silenziosa Tenere nuovamente premuto il pulsante per pi di 1 secondo per riattivare l allarme nu 23 lt V H DISCHARGING 2 BATTERY A OUTPUT SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF La modalita batteria 6 3 Modalita by pass Il display LCD in modalit by pass mostrato nel diagramma sottostante Sono visualizzati i dati relativi all alimentazione alla batteria al carico e all uscita dell UPS L UPS suoner ogni due minuti in modalit by pass Il codice 1 indica che l UPS sta lavorando in modalit by pass 20 iHz
60. tery breaker and start the UPS If it needs to replace the batteries while the UPS is running make sure the UPS would not shut down during the replacement If there is a battery breaker then turn it off first Disconnect the battery cable carefully and make sure no any exposed wires can be touched Reconnect the new batteries to the UPS by following section 5 8 Then turn on the battery breaker and press the ON switch to make the UPS do the battery test check whether the battery information is normal 31 10 Technical Data 10 1 Electrical specifications INPUT Modal No NL120N 1K 1K NL120N 2K 2K NL120N 3K 3K KS KS KS Phase Single Frequency 45 55 54 66 Hz Current A 9A 17A 26A OUTPUT Model No NL120N 1K 1K NL120N 2K 2K NL120N 3K 3K KS KS KS Power rating 1KVA O 8kW 2kVA 1 6kW 3kVA 2 4kW Voltage 200 208 220 230 240 142 VAC Frequency 50 60x0 2Hz Battery mode Wave form sinusoidal Derating to 9096 when the output voltage is adjusted to 208VAC Derating to 8096 when the output voltage is adjusted to 200VAC BATTERIES Model No NL120N 1K NL120N 2K NL120N 3K Number and type 3x12V 7Ah 8x12V 7Ah 8x12V 7Ah 10 2 Operating Environment Ambient Temperature 0 C to 45 C Operating humidity lt 95 Altitude lt 1000m Storage temperature 0 C to 45 C 32 10 3 Typical backup time Typical values at 25 in
61. ti anche alcuni termini ad esempio SHORT quando il carico o l uscita UPS in corto circuito e il gruppo di continuit si trova in modalit errore di inverter 23 7 Impostazioni tramite LCD La tensione in uscita la frequenza la modalit By pass la modalit ECO e la modalit conversione si possono selezionare direttamente tramite il LCD valori selezionabili per la tensione in uscita sono 208V 220V 230V e 240V valori selezionabili per la frequenza in uscita sono 50Hz e 60Hz La modalit operativa dell UPS pu essere selezionata tra la modalit normale la modalit ECO e la modalit conversione modalit By pass pu essere abilitata o disabilitata Tutte queste impostazioni possono tuttavia essere effettuate solo quando l UPS in modalit By pass o in modalit No Output In modalit By pass o No Output se si tiene premuto il pulsante Select sul pannello LCD per di un secondo verr visualizzato sul display una linea nera lampeggiante sotto i 50Hz Premendo pi a lungo il pulsante Select la linea nera lampeggiante si sposter successivamente su 60Hz e poi su 208V 220V 230V 240V By pass ON By pass OFF UPS ECO CVF Qui UPS la modalit normale inverter e UPS ECO e CVF saranno indicati in circolo nella posizione della corrente in uscita Se premendo il tasto Enter per pi di un secondo la linea nera lamp
62. tion Inspect the packaging carton and its contents for damage Please inform the transport agency immediately should you find signs of damage Please keep the packaging in a safe place for future use Note Please ensure that the incoming feeder is isolated and secured to prevent it from being switched back on again 5 2 Connection 1 UPS Input Connection If the UPS is connected via the power cord please use a proper socket with protection against electric current and pay attention to the capacity of the socket over 9A for NL120N 1K 1K KS over 17A for NL120N 2K 2K KS over 26A for NL120N 3K 3K KS If the UPS is connected via wires it is recommended to select the 2 5mm wire and the GND terminal should be grounded first by using the green yellow wire The wiring is shown as the following The UPS System has a input breaker on the cabinet But we still recommend users to connect an external breakers or protective components to the input terminals It is recommended to select the NFB Non Fuse Breaker instead of the traditional combination kit including breaker and fuse 12 When selecting the NFB the user refer to below table for detailed information when installation UPS INPUT NFB Model No VOLTAGE CURRENT NL120N 1K 1K KS 300Vac 10A NL120N 2K 2K KS 300Vac 20A NL120N 3K 3K KS 300Vac 32A 2 UPS Output Connection The output of the UPS is IEC socket types Simply plug the load
63. turbi della rete di alimentazione Un raddrizzatore trasforma in corrente continua la corrente alternata fornita dalla rete di alimentazione La corrente continua carica le batterie e alimenta l inverter il quale in base alla tensione della corrente continua genera una corrente alternata a onda sinusoidale pura che alimenta costantemente i carichi Sia i computer che le periferiche sono quindi alimentati interamente dall UPS In caso di interruzione della corrente l inverter viene alimentato dalle batterie che non necessitano di manutenzione Il presente manuale fa riferimento ai modelli elencati qui di seguito Si prega di dare conferma del modello che intende acquistare controllando visivamente il n del modello sul pannello posteriore dell UPS N Tipo N Modello Tipo Modello 1K 1K KS 2K Standard 2K KS Autonomia estesa 3K 3K KS Modello KS Autonomia estesa 4 Descrizione del pannello Pulsante Selezione Pulsante Enter OVER WARNINGFAULT 88 OVER VOLT LOAD um um Low mim ERROR SHORT I Sch 888v 888v 888v Schermo LCD 888A 888A 888A DISCHARGING 88Hz 88Hz OUTPUT SETTING 50 60Hz 208 220 230 240 Vac BYPASS ON OFF N TN it ale Pulsante ON SELECT ENTER Tacitazione cicalina Pulsante OFF pannello del display Pulsante Funzione Accensione del sistema UPS Premendo i