Manuale Utente User Manual ARCSKY90RGBW
Contents
1. SERIAL N SERIE N a wy Purchased by Acquistato da SURNAME COGNOME NAME NOME ADDRESS VIA N E 5 Ww CITY CITTA ZIP CODE C A P PROV Dealer s stamp and signature Timbro e firma del Rivenditore Purchasing date Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE MODEL MODELLO SERIAL N SERIE N T ng Purchased by Acquistato da SURNAME COGNOME C NAME NOME 4 ADDRESS VIA C Iu CITY CITT s ku ez NI ZIP CODE C A P Dealer s stamp and signature Timbro e firma del Rivenditore PROV M Purchasing date Data acquisto FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE Music amp Lights S r l entertainment technologies Via Appia km 136 200 04020 Itri LT ITALY SO 9001 2008 tel 39 0771 72190 fax 39 0771 721955 Certified Company www musiclights it info musiclights it ARCHWORK is a brand of Music amp Lights S r l company 2013 Music amp Lights S r l TR M 101 301 101 101 10 ARCHWORK un brand di propriet della Music amp Lights S r l
2. 2 Basic 3 Menu structure 4 DMX configurations 5 DMX mode 6 DMX addressing 7 DMX control 8 Static configuration 9 Dimmer 10 White calibration 11 Special functions 12 Operation with wireless DMX Maintenance 1 Maintenance and cleaning the unit 2 Trouble shooting Appendix 1 Exploded view Warranty ARCSKY90RGBW IP66 power extension cable IP66 signal extension cable Safety cable User manual N 10 11 11 11 13 15 15 15 15 16 17 17 18 2 ARCSKYSORGBW WARNING Before carrying out any operations with the unit carefully read this instruction A manual and keep it with cure for future reference It contains important information about A the installation usage and maintenance of the unit SAFETY General instruction The products referred to in this manual conform to the European Community Directives and are there fore marked with ce The unit is supplied with hazardous network voltage 230V Leave servicing to skilled personnel only Never make any modifications on the unit not described in this instruction manual otherwise you will risk an electric shock Connection must be made to a power supply system fitted with efficient earthing Class appliance ac cording to standard EN 60598 1 It is moreover recommended to protect the supply lines of the units from indirect contact and or shorting to earth by using appropriately sized residual current devices The connecti
3. Input voltage AC 100V 240V Max power 310W Optics 30 6 12 55 25x69 DMX control channels RGBW dimmer 0 100 Interface DMX Controllable sections 1 Mains connection 3m cable input only Data connection 3m cable input output Protection IP66 Operating temperature 40 C 45 C Housing material Die cast aluminium Housing color Off White Dimensions WxHxD 706x310x252 mm Weight 24kg ARCSKYSORGBW Dimensioni prodotto n d 252 Fig 1 Diagramma di luminosita Light Intensity Distribution 6 6 2 2 10m 1924 2600lx 1 00m Q E 481 650lx 1 99m q 30m S 214 289lx 2 99m S 40m t 120 163lx 3 98m 50m 77 1041 4 98 2 ix 9 m Average Beam Angle 5096 5 7 m k pens cd Hori Intensity cd Eavg Emax Beam Angle 5 7 Beam Width Fig 2 8 ARCSKYSORGBW 1 3 ELEMENTI DI COMANDO E DI COLLEGAMENTO Fig 3 1 BLOCCOLED 2 SISTEMA MECCANICO PER LA REGOLAZIONE individuale e simultanea dei blocchi LEDs 3 BOX adattatore di alimentazione 4 SUPPORTI ganci omega per applicazioni in sospensione del proiettore 5 POWERIN per il collegamento ad una presa di rete 100 240V 50 60Hz tramite il cavo rete con spina in dotazione 6 Connessione XLR a tre poli DMX IN XLR a 3 po
4. 13 S16 1 o JaquuaujeJ ASPA d SUOI IPUOD Bd URIEND les u np ensqv irsyufipoisnurwMaM 5 Q M Ano uo SuoOnipuo eejueJenr Y JO UOISJ9A InJ etu puy ue no suone n6o4 Bunsixe QM adueldwos ul yun au S49A02 aazuesenb ou DIZuDIDb IP 010211422 Jap auolzbjJuasaid a uaw balun DJD DAD a DIZuDIDD b l p aya WE mny 0142234Dddb jap 210ssassod 0214092 D ouos iuanbasuo Iu2su 12 o ylodsou ip s ds lqouodsp HONNI 1 6 ajodounw appduup ausajsa Ibd aj DIZUDIDO asn sa 014223 Dddb jjap uolzn nsos DJ apanad uou pIZUDIDO D OSSA 01018 DIS O012224DddD 0 9ya un b nid by uou DiZuDJDD D ojbiudo4ddp uou osn pp pizM dull 105 02 150 6 5 25 04394 NS JI opubinui 0301351631 asassa ond I DAIJDUJA D U arsiubippisnurwMM 0115 ns 0310poud Jap 120115 Ip orsinbab odop bbaid Ig DIZUDADY Ip I D49U9 IUOIZIDUO 01104153 DIZUDADE Ip I D42U8 5 ll p 0 Sa I 84D nsuo2 a Iqissod a1rsiubi 3isnur man 15 ins 2AlJDUuLOU liD sbq ul DIZUDADD 0310po4d MODEL MODELLO
5. NoFunction 000 009 Strobe Slow Fast 010 255 DIMMER SPEED off 000 009 Speed 1 Fastest 010 069 SPECIAL2 Speed 2 070 129 Speed 3 130 189 Speed 4 Slovvest 190 255 CH Function in SPECIAL mode Value 1 MASTER DIMMER 0 100 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 ARCSKYSORGBW 17 3 8 MODALIT STATIC Per impostare il bilanciamento personalizzato del rosso verde blu e bianco Premere il tasto MENU fino a quando sul display non appare STAT quindi premere il tasto ENTER Selezionare il canale rosso verde blu o bianco RED GREN BLUE WHITE attraverso i tasti UP DOWN Per confermare premere il tasto ENTER e Impostare i valori 000 255 attraverso i tasti UP DOWN Infine impostare il valore STRB tra 0 20Hz mediante i tasti UP DOWN 3 9 FUNZIONE DIMMER Selezionando la funzione DIM possibile entrare nella modalit dimmer In particolare quando im postato su OFF L RGB e il MASTER DIMMER sono lineari Dim 1 2 3 4 rappresentano invece diversi valori di velocit nella modalit non lineare DIM 1 il valore pi veloce mentre DIM 4 il pi lento NOTA Le impostazioni di fabbrica sono su DIM 4 3 10 CALIBRAZIONE BIANCO Per impostare il bilanciamento personalizzato della temperatura colore bianco Premere il tasto MENU fino a quando sul display non appare CALIB quindi premere il tasto ENTER Selezionare una delle 11 impostazioni color
6. 12 55 25x69 DMX control channels RGBW dimmer 0 100 Interface DMX Controllable sections 1 Mains connection 3m cable input only Data connection 3m cable input output Protection IP66 Operating temperature 40 C 45 C Housing material Die cast aluminium Housing color Off White Dimensions WxHxD 706x310x252 mm Weight 24kg ARCSKYSORGBW Dimensional drawings NO i Photometric diagram Light Intensity Distribution 6 Average Beam Angle 5096 5 7 Fig 2 252 Fig 1 6 2 2 10m 8 1924 2600lx 1 00m Q s 481 650lx 1 99m q 30m g 214 289 x 2 99m S 40m 120 163lx 3 98m 50m 77 1041 4 98 Vert Intensity cd x 5 Hori Intensity cd Eavg Emax Beam Angle 5 7 Beam Width 6 ARCSKYSORGBW 1 3 OPERATING ELEMENTS AND CONNECTIONS Fig 3 1 LED panel 2 MECHANICAL SYSTEM for individual positioning of Led panels 3 POWER SUPPLY CASING SET 4 OMEGA KIT with quick lock system 5 POWER IN for connection to a socket 100 240V 50 60Hz via the supplied mains cable 6 XLR connection DMX IN 3 pole XLR 1 ground 2 DMX 3 DMX DMX OUT 3 pole XLR 12 ground 2 DMX 3 DMX ARCSKYSORGBW 7 2 INSTALLATION 2 1 MOUNTING The ARCSKY9
7. 512 una volta raggiunta la fine della linea stessa venga riflesso indietro lungo il cavo provocando in certe condizioni e lunghezze la sua sovrap posizione al segnale originale e la sua cancellazione La terminazione deve essere effettuata sull ultima unit della catena saldando una resistenza di 1200 minimo 1 4W tra i Pin 2 e 3 1200 Esempio connettore XLR a 3 pin Fig 10 ARCSKYSORGBW 15 3 7 TABELLA CANALI DMX ARCI ARC2 D CH Function in ARC mode Value CH Function in ARC2 D mode Value 1 RED 1 MASTER DIMMER 0 100 000 255 0 100 000 255 2 GREEN 2 RED 0 100 000 255 0 100 000 255 3 BLUE 3 GREEN 0 100 000 255 0 100 000 255 4 BLUE _ O 0 100 000 255 ARC1 D 5 WHITE 0 100 000 255 CH Function in ARC1 D mode Value 1 MASTER DIMMER ARCFULL 0 100 000 255 CH Function in ARCFULL mode Value 0 100 000 255 3 GREEN 1 DIMMER 0 100 000 255 0 100 000 255 4 BLUE 2 RED 0 100 000 255 0 100 000 255 3 GREEN 0 100 000 255 ARC2 a BEUE 0 100 000 255 COLOR MACRO CH Function in ARC2 mode Value No Function 000 010 Red 100 Green Up Blue 0 011 030 1 RED Red Down Green 100 Blue 0 031 050 0 100 000 255 Red 0 Green 100 Blue Up 051 070 GREEN 5 Red 0 Green Down Blue 100 96 071 090 2 09 10096 000 255 Red Up Green 0 Blue 100 091 110 Red 100 Green 0 Blue Dow
8. Down Blue 100 151 170 Off 000 009 Red 100 Green 100 BI 100 Wh100 171 200 7 Speed 1 Fastest 010 069 White 1 3200K 201 205 Speed 2 070 129 White 2 3400K 206 210 Speed 3 130 189 White 3 4200K 211 215 Speed 4 Slowest 190 255 White 4 4900K 216 220 White 5 5600K 221 225 White 6 5900K 226 230 White 7 6500K 231 235 SOLID White 8 7200K 236 240 White 9 8000K 241 245 White 10 8500K 246 250 CH Function in SOLID mode Value White 11 10000K 251 255 RGB amp MASTER DIMMER STROBE 1 0 100 000 255 7 NoFunction 000 009 Strobe Slow Fast 010 255 DIMMER SPEED off 000 009 Speed 1 Fastest 010 069 SPECIAL2 Speed 2 070 129 Speed 3 130 189 Speed 4 Slovvest 190 255 CH Function in SPECIAL mode Value 1 MASTER DIMMER 0 100 000 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 ARCSKYSORGBW 15 3 8 STATIC CONFIGURATION To set the custom balance of red blue green and white Press the button MENU so many times until the display shows STAT Press the button ENTER to confirm Selectthe color red green blue white or amber RED GREN BLUE WHITE through the buttons UP DOWN and then press the button ENTER Set the value 000 255 through the buttons UP DOWN Set the value of the STRB 0 20 through the buttons UP DOWN 3 9 DIMMER Enter DIMX to select dimmer mode and dimmer speed When dimmer is set to OFF the RGBW and MASTER DIMMER are
9. RGB settings SETTINGS UC Output matches that of product s previous versions RESET m Restores factory defaults ARCSKYSORGBW 13 3 4 CONFIGURAZIONI CANALI DMX LARCSKY90RGBW dispone di 8 configurazioni dei canali DMX Premere il tasto MENU fino a quando sul display non appare PERSON quindi premere il tasto ENTER Attraverso i tasti UP DOWN selezionare la configurazione DMX desiderata ARC1 ARC1 D ARCFULL REMO TE SOLID ARC2 ARC2 D SPECIAL2 Le tabelle a pagina 15 indicano le modalit di funzionamento e i relativi valori DMX l unit possiede cavo di segnale a 3 fili 3 5 MODALITA DMX Per poter entrare nella modalit DMX premere il tasto MENU fino a quando sul display non appare DMX quindi premere il tasto ENTER Premere i tasti UP DOWN per selezionare il valore desiderato 001 512 tenere premuto per lo scorri mento veloce Altermine dell impostazione il valore verr salvato automaticamente 3 6 IMPOSTAZIONE DELL INDIRIZZO DI START Per poter comandare ARCSKY90RGBW con un unit di comando luce occorre impostare l indirizzo di start DMX per il primo canale DMX Se per esempio sull unit di comando previsto l indirizzo 33 per comandare la funzione del primo canale DMX si deve impostare sull ARCSKY90RGBW l indirizzo di start 33 Le altre funzioni del pannello saranno assegnate automaticamente agli indirizzi successivi Segue un esempio con indirizzo 33 di start e una configurazion
10. current function value or option within a menu 10 ARCSKYSORGBW 3 3 MENU STRUCTURE MAIN FUNCTION SELECTION SUB SELECTION DESCRIPTION DMX 001 512 Sets the DMX starting address ARC1 3 channel RGB control ARC 1 D 4 channel RGB control dimmer ARC FULL 7 channel RGB control Color Macro dimmer strobe Dimmer Speed PERSON 57 SOLID 1 channel RGB amp dimmer ARC2 ARC2 D SPECIAL 2 Module RGB RED 000 255 WHITE 01 11 17 Determines the white balance for the color macros BLUE 000 255 CALIB WHIT 000 255 RED 000 255 RGB TOW GREN 000 255 Determines the white balance when RGBTOW is active BLUE 000 255 OFF Dimmer works in linear mode DIM1 DIMMER DIM2 Dia Dimmer works in non linear mode from fast to slow DIM4 RED GREN STATIC BLUE ee Configures the static color and effect WHITE STRB 0 20 OFF Maximum output unbalanced white COLOR RGBTOW White output is as per CALIB gt RGB settings SETTINGS UC Output matches that of product s previous versions RESET m Restores factory defaults ARCSKYSORGBW 11 3 4 DMX CONFIGURATIONS ARCSKY90RGBW is equipped with 8 DMX configuration Press the button MENU so many times until shows PERSON and press the button ENTER to confirm Select the desired DMX configuration ARC1 ARC1 D ARCFULL REMOTE SOLID ARC2 ARC2 D SPECIAL2 through the buttons UP DOWN Thetables on page 13 indicate the operat
11. linear The Dim1 2 3 4 are speed modes of the non linear dimmer DIM1 is the faster while DIM4 is the slowest NOTE The factory default setting is DIM4 3 10 WHITE CALIBRATION Enter the CALIB mode to select white color of different color temperature Press the button MENU so many times until show CALIB and press the button ENTER to confirm There are 11 pre programmed white colors WHITE01 WHITE11 can be edited by using red green blue and white Red Green Blue White through the UP DOWN NOTE In the ARCFULL configuration is possible to balance custom color temperature settings by select ing white WHITEO1 WHITE11 of CH5 Select RGB TOW to set the values 000 255 of red green and blue on DMX channels achieving different white colors 3 11 SPECIAL FUNCTIONS Press the button menu and select through the directional buttons the SETTINGS mode and press the button ENTER to confirm It is possible to view to following functions COLOR COLOR is for activate deactivate the color calibration functions When RGB is selected on RGB 255 255 255 the color is displayed as calibrated in CAL2 RGB When COLOR is set OFF son RGB 255 255 255 the RGB values are not adjusted and the output is most powerful When UC s selected the RGB output adjusted to a standard preset universal color which bal ances fixtures from different generations RESET n order to reset custom modes to de
12. ottico 2 Risoluzione dei problemi dba Ui Appendice 1 Vista esplosa Un Certificato di garanzia ARCSKY90RGBW Estensione IP66 cavo di segnale Estensione IP66 cavo di alimentazione con spina Staffe di fissaggio Manuale utente 1 Funzionamento tramite il controller ARCMAT A 10 11 12 13 13 T3 15 17 17 17 17 18 19 19 20 4 ARCSKYSORGBW ATTENZIONE Prima di effettuare qualsiasi operazione con l unit leggere con attenzione A questo manuale e conservarlo accuratamente per riferimenti futuri Contiene informazioni importanti riguardo l installazione l uso e la manutenzione dell unit SICUREZZA Avvertenze generali prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunit Europea e per tanto recano la sigla ce Il dispositivo funziona con pericolosa tensione di rete 230V Non intervenire mai al suo interno al di fuori delle operazioni descritte nel presente manuale esiste il pericolo di una scarica elettrica obbligatorio effettuare il collegamento ad un impianto di alimentazione dotato di un efficiente messa a terra apparecchio di Classe secondo norma EN 60598 1 Si raccomanda inoltre di proteggere le linee di alimentazione delle unit dai contatti indiretti e o cortocircuiti verso massa tramite l uso di interruttori differenziali opportunamente dimensionati Le operazioni di collegamento alla rete di distribuzione dell energia elettric
13. scrupolosamente a tutte le normative in materia di sicurezza vigenti nel paese di utilizzo Installare l unit in un luogo ben ventilato La distanza minima tra il proiettore e le pareti circostanti deve essere superiore a 50 cm e non devono essere ostruite in nessun caso le aperture di aerazione Mantenere i materiali infiammabili ad una distanza di sicurezza dall unit I filtri le lenti o gli schermi ultravioletti se danneggiati possono limitare la loro efficienza I LED devono essere sostituiti se danneggiati o termicamente deformati Non guardare direttamente il fascio luminoso Tenete presente che i veloci cambi di luce possono pro vocare attacchi d epilessia presso persone fotosensibili o epilettiche ARCSKYSORGBW 5 INFORMAZIONI GENERALI Spedizioni e reclami Le merci sono vendute franco nostra sede e viaggiano sempre a rischio e pericolo del distributore clien te Eventuali avarie e danni dovranno essere contestati al vettore Ogni reclamo per imballi manomessi dovr essere inoltrato entro 8 giorni dal ricevimento della merce Garanzie e resi Il prodotto coperto da garanzia in base alle vigenti normative Sul sito www musiclights it possibile consultare il testo integrale delle Condizioni Generali di Garanzia Si prega dopo l acquisto di procedere alla registrazione del prodotto sul sito www musiclights it In alternativa il prodotto pu essere registrato compilando e inviando il modulo riportato alla fine de
14. t al controller esterno ARCMAT attraverso il cavo di segnale Per ulteriori informazioni sul funzionamento del controller ARCMAT consultare il relativo manuale dedi cato AC POWER IN Figo ARCMAT GND E Data L Data N DMX OUTPUT Presa XLR Pin1 Massa Schermo Pin2 Negativo Pin3 Positivo Pin1 Massa Schermo Nero Pin2 Negativo Verde Pin3 Positivo Rosso CONNETTORE DI SEGNALE Fig 7 NOTA Connettere il controller ARCMAT alle unit disposte in serie che si desidera controllare Tutte le unit connesse all ARCMAT devono essere settate allo stesso modo per poter funzionare cor rettamente Impostare i parametri e le funzioni sulle unit attraverso il controller Si possono controllare contemporaneamente 20 unit collegate in serie ARCSKYSORGBW 3 2 IMPOSTAZIONE BASE Per accendere l ARCMAT inserire le 2 batterie da 1 5V incluse e premere il tasto POWER Per spegnere l ARCMAT invece non premere nessun tasto o non assegnare nessuna funzione per circa un minuto Il controller dispone di un LED display e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 8 NOTA Dopo circa un minuto fra due pressioni dei tasti la procedura d impostazione entra in modalit standby POWER Tasto per l accensione dell ARCMAT Il dispositivo si spegner automaticamente se passer circa un minuto senza premere tasti 0 assegnare funz
15. 0RGBW may be set up on a solid and even surface By means of the fixing facilities of the base plate the unit can also be mounted upside down to a cross arm The base plate is shown in fig 4 For fixing stable mounting clips are required According to the figure the bolts of the brackets are placed into the openings provided in the base plate and turned clockwise until they lock to the stop The mounting place must be of sufficient stability and be able to support a weight of 10 times of the unit s weight When carrying out any installation always comply scrupulously with all the regulations particularly regarding safety currently in force in the country in which the fixture s being used Install the projector at a suitable location by means of the C clamp Always additionally secure the projector with the safety rope from falling down For this purpose fas ten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm Adjust the position of the projector using the mechanical system 2 8 ARCSKYSORGBW 3 FUNCTIONS AND SETTINGS 3 1 OPERATION VIA ARCMAT CONTROLLER After making the connection ARCSKY90RGBW supply 230V 50Hz connect the unit to the external con troller ARCMAT through the signal cable For more information on the operation of the controller ARCMAT consult the instruction manual AC POWER IN Figo AR
16. CMAT GND E Data L Data N DMX OUTPUT XLR socket Pin1 GND Shield Pin2 Negative Pin3 Positive Pin1 GND Shield Black Pin2 Negative Green Pin3 Positive Red SIGNAL CONNECTOR Fig 7 NOTE Connect the DMX coder to the units in series All connected units will be set with the same information Setcorresponding DMX address Personality Calibration and Dimmer of fixture through the DMX coder Amaximum of 20 units in series can be set by the DMX Coder at the same time 3 2 BASIC ARCSKYSORGBW To turn the ARCMAT insert the 2 batteries 1 5V included and press the POWER button To turn off the ARCMAT however do not press any buttons or do not assign any function for about a minute The control ler has an LED display and 4 buttons to access the functions of the control panel Note After a minute or two keystrokes the setting procedure is in standby mode POWER Used to turn on the ARCMAT The device will turn off automatically if one minute passes without pressing buttons or without assign function POWER o e MENU ENTER DOWN Fig 8 MENU UP Used to access the Scrolls through menu menu DMX PERSON options in ascending CALIB DIMMER order STATIC SETTING See section 3 3 Used to return a previous menu option DOWN Scrolls through menu options in descending order ENTER Used to select and store the current menu or confirm the
17. FULL mode Value 0 100 000 255 3 GREEN 1 DIMMER 0 100 000 255 0 100 000 255 4 BLUE 2 RED 0 100 000 255 0 100 000 255 3 GREEN 0 100 000 255 ARC2 a BEUE 0 100 000 255 COLOR MACRO CH Function in ARC2 mode Value No Function 000 010 Red 100 Green Up Blue 0 011 030 1 RED Red Down Green 100 Blue 0 031 050 0 100 000 255 Red 0 Green 100 Blue Up 051 070 GREEN 5 Red 0 Green Down Blue 100 96 071 090 2 09 10096 000 255 Red Up Green 0 Blue 100 091 110 Red 100 Green 0 Blue Down 111 130 3 BLUE R Red 100 Green Up Blue Up 131 150 0 100 000 255 Red Down Green Down Blue 100 151 170 4 WHITE Red 100 Green 100 BI 100 Wh100 171 200 0 100 000 255 White 1 3200K 201 205 14 ARCSKYSORGBVV CH Function in ARCFULL mode Value CH Function in SPECIAL mode Value White 2 3400K 206 210 BLUE White 3 4200K 211 215 0 100 000 255 White 4 4900K 216 220 WHITE White 5 5600K 221 225 5 midi Dios 5 White 6 5900K 226 230 White 7 6500K 231 235 COLOR MACRO White 8 7200K 236 240 77 1751 White 10 8500K 246 250 Red Down Green 100 Blue 0 96 031 050 STROBE Red 0 96 Green Down Blue 100 96 071 090 6 000 009 Red Up Green 0 Blue 100 96 091 110 Strobe Slow Fast 010 255 Red 100 Green 0 Blue Down 111 130 Red 100 Green Up Blue Up 131 150 DIMMER SPEED Red Down Green
18. a devono essere effettuate da un installatore elettrico qualificato Verificare che frequenza e tensione della rete corrispondono alla frequenza ed alla tensione per cui l unit predisposta indicate sulla targhetta dei dati elettrici L unit non per uso domestico solo per uso professionale Evitare di utilizzare l unit in luoghi soggetti a vibrazioni o a possibili urti in luoghi a temperatura superiori ai 45 C Evitare che nell unit penetrino liquidi infiammabili acqua o oggetti metallici Non smontare e non apportare modifiche all unit Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al pi vicino centro di assistenza tecnica autorizzato Se si desidera eliminare il dispositivo definitivamente consegnarlo E per lo smaltimento ad un istituzione locale per il riciclaggio Attenzioni e precauzioni per l installazione Se il dispositivo dovesse trovarsi ad operare in condizioni differenti da quelle descritte nel presente manuale potrebbero verificarsi dei danni in tal caso la garanzia verrebbe a decadere Inoltre ogni altra operazione potrebbe provocare cortocircuiti incendi scosse elettriche rotture etc Prima di iniziare qualsiasi operazione di manutenzione o pulizia sull unit togliere la tensione dalla rete di alimentazione assolutamente necessario proteggere l unit per mezzo di una fune di sicurezza Nelleseguire qual siasi intervento attenersi
19. atching amplifier For those connections the use of balanced microphone cable is not recommended because it cannot transmit control DMX data reliably 12 ARCSKYSORGBW Connect the controller DMX input to the DMX output of the first unit Connect the DMX output to the DMX input of the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the signal cable has to run longer distance is recommended to insert a DMX termination on the last unit The termination avoids the risk of DMX 512 signals being reflected back along the cable when they reaches the end of the line under certain conditions and with certain cable lengths this could cause them to cancel the original signals The termination has to be prepared by soldering a 1200 1 4W resis tor on the last element of the DMX chain between pins 2 and 3 1200 Example 3 pin XLR connector Fig 10 ARCSKYSORGBW 13 3 7 DMX CONTROL ARCI ARC2 D CH Function in ARC mode Value CH Function in ARC2 D mode Value 1 RED 1 MASTER DIMMER 0 100 000 255 0 100 000 255 2 GREEN 2 RED 0 100 000 255 0 100 000 255 3 BLUE 3 GREEN 0 100 000 255 0 100 000 255 4 BLUE _ O 0 100 000 255 ARC1 D 5 WHITE 0 100 000 255 CH Function in ARC1 D mode Value 1 MASTER DIMMER ARCFULL 0 100 000 255 CH Function in ARC
20. ble can not be resolved by the procedure given in the table 18 ARCSKYSORGBW 5 APPENDIX 5 1 EXPLODED VIEW ITEM Head casing set Mounting bracket Adjusting screw Mounting rod W DMX antenna optional Power supply casing set Head casing front section Tempered glass Head casing gasket Lens board Lens LED board Rotating bracket N Place Stamp Here Affrancare Via Appia Km 136 200 Music amp Lights S r l 04020 Itri LT Italy Spett le 41V21411445 JALNVYVND VIZNVYYD 104 OLVIIAILYTI 11 9je yn4a2 aajuesenb aui jo uone1uesaud uo Ajajos passopua s aazuesenb y Jo AUpijea y sasodind ile 104 jueuudinbe ay Jo jSuMo 2u1J0 it Iqisuodsai ase sysu juanbasqns pue 51502 140dsuej aajuesenb y ul p pni ul jou ase syed ajqeAowad pue Sau21IMs s lpueu sdwe syed jeusayxq u uldinb 24 Jo 1usuje2e dai BY 104 UOIsIAOJd OU sayewi sesjuejenb y u q sey 1ueuudinbe y JI AP H aq s 5uo ou jm es1uejenD y p pni x eje juawdinba y Jo Huljpuey 1224102u pue e uauedxeul Aq pesne si q aajuesenb Jno uo a gejiene w104 eui B lp s pue ul 6ui jy pa4o3sibau Osje aq ue 1onpoud ay arsiubiporsnur ww uo Sul55o 31 eseupund noZ Jaye uoos 1ueuudinbe Jo adaid y
21. e a 4 e a 7 canali DMX Numero Indirizzo di Indirizzo DMX Prossimo indirizzo di start Prossimo indirizzo di start Prossimo indirizzo di start canali DMX start esempio occupati possibile per unit n 1 possibile per unit n 2 possibile per unit n 3 4 33 33 36 37 41 45 y 33 33 39 40 47 54 Esempio di configurazione a 7 canali DMX modalit ARCFULL DMX Address 33 DMX Address 40 DMX Address 47 DMX Address 54 La connesione DMX realizzata utilizzando cavi schermati 2 poli massa ritorti con impendenza 1200 e bassa capacit Per il collegamento fare riferimento allo schema di connessione riportato a pag 9 Per passaggi lunghi pu essere necessario l inserimento di un amplificatore DMX In tal caso sconsigliato utilizzare nei collegamenti cavo bilanciato microfonico poich non in grado di trasmettere in modo affidabile i dati di controllo DMX Fig 9 14 ARCSKYSORGBW e Collegare l uscita DMX del controller con l ingresso DMX della prima unit e Collegare quindi l uscita DMX con l ingresso DMX della successiva unit l uscita di quest ultima con l ingresso di quella successiva e via dicendo finch tutte le unit sono collegate formando una catena e Per installazioni in cui il cavo di segnale deve percorrere lunghe distanze consigliato inserire sull ulti ma unit una terminazione DMX La terminazione evita la probabilit che il segnale DMX
22. e bianco pre programmate WHITEO1 WHITE11 Le impostazioni possono essere modificate intervenendo sui valori 000 255 relativi ai canali rosso verde blu e bianco Red Green Blue White attraverso i tasti UP DOWN NOTA Nella configurazione ARCFULL possibile effettuare il bilanciamento personalizzato della tempe ratura colore bianco selezionando le impostazioni WHITE01 WHITE11 del canale 5 Selezionare RGBTOW per impostare i valori 000 255 relativi ai canali rosso verde e blu 3 11 FUNZIONI SPECIALI Premere il tasto MENU e selezionare attraverso i tasti UP DOWN la funzione SETTINGS per confermare premere il tasto ENTER possibile accedere alle seguenti funzioni COLOR Selezionando la funzione COLOR possibile attivare disattivare le modalit calibratura colore Quando RGBTOW selezionato su RGB 255 255 255 il colore visualizzato come calibrato nella modalit RGB TO W Quando COLOR impostato su OFF su RGB 2255 255 255 il colore non pu essere regolato e l uscita mostrer la massima potenza Quando UC selezionato i colori sono regolati secondo un preset universale standard RESET Selezionando la funzione RESET possibile ripristinare i valori di default 18 ARCSKYSORGBW 3 12 FUNZIONAMENTO WIRELESS DMX Quando si utilizza questo dispositivo con ricevitore W DMX installato all interno l unit pu essere collo cata ad una distanza di 200 metri dal t
23. e polvere fumo e altre particelle Solo cos la luce pu essere irradiata con la luminosit massima Per la pulizia usare un panno morbido pulito e un detergente per vetri come si trovano in commercio Quindi asciu gare le parti delicatamente Attenzione consigliamo che la pulizia interna sia eseguita da personale qualificato 4 2 RISOLUZIONE DEI PROBLEMI Anomalie Possibili cause Controlli e rimedi Mancanza di alimentazione di rete Verificare la presenza della tensione alimentazione Dimmer impostato a 0 incrementare i valori del canale dimmer Il proiettore non illumina Tutti i colori impostati a 0 incrementare i valori dei canali colori LED difettoso i Sostituire scheda LED Scheda LED difettosa Sostituire scheda LED AP Lenti sporche Pulire il dispositivo regolarmente Bassa intensit di luce generale Lente disallineata Installare il gruppo ottico correttamente e Mancanza di alimentazione di rete Cavo di alimentazione danneggiato Alimentatore interno difettoso Verificare la presenza della tensione alimentazione Controllare il cavo di alimentazione Sostituire l alimentatore interno Il proiettore non alimentato ndirizzamento DMX errato Controllare il pannello di controllo e Il proiettore non risponde al l indirizzamento delle unit DMX Cavo di segnale DMX difettoso Controllare il cavo di segnale DMX Rimbalzo segnale DMX Installare una terminazione DMX come suggerito R
24. fault values select RESET 16 ARCSKYSORGBW 3 12 OPERATION WITH WIRELESS DMX When using this lighting fixture with W DMX receiver installed inside the fixture may be placed at a range of 200m from W DMX transmitter W DMX Fig 9 e First use DMX ENCODER to set operation mode to DMX and set DMX address Open the protective cover to gain access to the W DMX receiver card Position both of the dip switches at the ON position The red POWER indicator will display Press and hold the RESET button until the green SIGNAL indicator is off This state indicates that the W DMX receiver board is ON and fully RESET available to pair with W DMX transmitter amp G SIGNAL POVVE ARCSKYSORGBW 17 4 MAINTENANCE 4 1 MAINTENANCE AND CLEANING THE UNIT e Make sure the area below the installation place is free from unwanted persons during setup Switch off the unit unplug the main cable and wait until the unit has cooled down All screws used for installing the device and any of its parts should be tightly fastened and should not be corroded Housings fixations and installation spots ceiling trusses suspensions should be totally free from any deformation The main cables must be in impeccable condition and should be replaced immediately even when a small problem is detected Itis recommended to clean the front at regular intervals fro
25. ing mode and DMX value As DMX interface the unit has a 3 wire signal cable 3 5 DMX MODE Press the button MENU so many times until the display shows DMX Press the button ENTER to confirm Press the buttons UP and DOWN to select the desired value 001 512 old to scroll quickly After setting the value is saved automatically 3 6 DMX ADDRESSING To able to operate the ARCSKY90RGBW with a light controller adjust the DMX start address for the first a DMX channel If e g address 33 on the controller is provided for controlling the function of the first DMX channel adjust the start address 33 on the ARCSKY9ORGBW The other functions of the light effect panel are then automatically assigned to the following addresses An example with a start address 33 and configuration to 4 and 7 DMX channels Number of Start address DMX Address Next possible start Next possible start Next possible start DMX channels example occupied address for unit No 1 address for unit No 2 address for unit No 3 4 33 33 36 37 41 45 7 33 33 39 40 47 54 Example 7 DMX channels configuration mode ARCFULL DMX Address 33 DMX Address 40 DMX Address 47 DMX Address 54 Fig 9 DMX connection employs shielded pair twisted cables 2 poles with 1200 impedance and low capacity For connection refer to the connection diagram shown on page 7 Over long runs can be necessary to insert a DMX level m
26. ioni POWER o e MENU ENTER DOWN Fig 8 MENU UP DOWN Per selezionare la Per scorrere attraverso Per scorrere attraverso funzione desideratao le diverse funzioniin le diverse funzioni in tornare ad un opzione del menu precedente ordine discendente o aumentare il valore della funzione stessa ordine ascendente o diminuire il valore della funzione stessa 11 ENTER Per entrare nel menu selezionato 0 confermare il valore attuale della funzione o l opzione all interno di un menu 12 ARCSKYSORGBW 3 3 STRUTTURA MENU MAIN FUNCTION SELECTION SUB SELECTION DESCRIPTION DMX 001 512 Sets the DMX starting address ARC1 3 channel RGB control ARC 1 D 4 channel RGB control dimmer ARC FULL 7 channel RGB control Color Macro dimmer strobe Dimmer Speed PERSON 57 SOLID 1 channel RGB amp dimmer ARC2 ARC2 D SPECIAL 2 Module RGB RED 000 255 WHITE 01 11 17 Determines the white balance for the color macros BLUE 000 255 CALIB WHIT 000 255 RED 000 255 RGB TO W GREN 000 255 Determines the white balance when RGBTOW is active BLUE 000 255 OFF Dimmer works in linear mode DIM 1 DIMMER DIM 2 Dia Dimmer works in non linear mode from fast to slow DIM4 RED GREN STATIC BLUE ee Configures the static color and effect WHITE STRB 0 20 OFF Maximum output unbalanced white COLOR RGBTOW White output is as per CALIB gt
27. ivolgersi a un centro di assistenza tecnico autorizzato in caso di problema non riportato in tabella o che non possono essere risolti mediante la procedura riportata in tabella 20 ARCSKYSORGBVV 5 APPENDICE 5 1 VISTA ESPLOSA ITEM Head casing set Mounting bracket Adjusting screw Mounting rod W DMX antenna optional Power supply casing set Head casing front section Tempered glass Head casing gasket Lens board Lens LED board Rotating bracket N All rights reserved by Music amp Lights S r l No part of this instruction manual may be reproduced in any form or by any means for any commercial use In order to improve the quality of products Music amp Lights S r l reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice All revisions and updates are available in the manuals section on site www musiclights it ARCSKYSORGBW TABLE OF CONTENTS Packing content Safety General instructions Warnings and installation precautions General information nc N ARAB w w w ww LI LI WI C9 UJ CU CO UJ Introduction 1 Description 2 Technical specifications 3 Operating elements and connections Installation 1 Mounting Functions and settings 1 Operation via ARCMAT controller
28. l manuale A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia Music amp Lights constata tramite ve rifica sui resi la difettosit dichiarata correlata all appropriato utilizzo e l effettiva validit della garanzia provvede quindi alla riparazione dei prodotti declinando tuttavia ogni obbligo di risarcimento per danni diretti o indiretti eventualmente derivanti dalla difettosit 6 ARCSKYSORGBW 1 INTRODUZIONE 1 1 DESCRIZIONE ArcSKY90 un proiettore outdoor di straordinaria potenza il primo con sorgente LED che possa realmente eguagliare fari panoramici con lampada a scarica da 1500W La sorgente luminosa si compone di 90LED RGBW da 3W garantendo un elevata efficienza di riproduzione su tutta la gamma cromatica La struttura disegnata per garantire un grado di protezione IP66 rendendo arcSKY adatto per qualsiasi progetto outdoor anche nelle condizioni pi estreme L ampio range di ottiche disponibili permette di passare da un fascio narrow 6 ad una diffusione wide 55 sia per proiezioni da distanza ravvicinata che per le lunghe distanze ArcSKY si configura essere un proiettore dal profilo eco friendly con i soli 310W di assorbimento permet te di ridurre sensibilmente i consumi energetici nei progetti 1 2 SPECIFICHE TECNICHE ARCSKY90RGBW LED source 90x3W 24R 246 248 18W Lumen 8500lm Peak intensity 260000cd 6
29. li 12massa 2 DMX 3 DMX DMX OUT XLR a 3 poli 12 massa 2 DMX 3 DMX ARCSKYSORGBW 9 2 INSTALLAZIONE 2 1 MONTAGGIO ARCSKY90RGBW pu essere collocato su un piano solido Inoltre grazie ai fori di fissaggio l unit pu essere montata anche a testa in gi su una traversa fig 4 Per il fissaggio occorrono dei supporti robusti per il montaggio Come si vede nell illustrazione i perni del sistema di aggancio rapido dei supporti omega sono da inserire nelle apposite sedi del proiettore dove vengono bloccati con una rotazione in senso orario fino all arre sto L area di collocazione deve avere una stabilit sufficiente e supportare almeno 10 volte il peso dell unit Inoltre assicurarsi di rispettare tutte le avvertenze in materia di sicurezza Fissareil proiettore attraverso gli appositi ganci ad una collocazione idonea assolutamente necessario assicurare il proiettore contro la caduta utilizzando un cavo di sicurezza in particolare collegare il cavo in un punto adatto in modo che la caduta del proiettore non possa supe rare i 20 cm e Orientare il proiettore attraverso il sistema meccanico 2 per ottenere una regolazione individuale e simultanea dei blocchi LEDs fig 5 10 ARCSKYSORGBW 3 FUNZIONI E IMPOSTAZIONI 3 1 FUNZIONAMENTO TRAMITE IL CONTROLLER ARCMAT Dopo aver effettuato il collegamento dell ARCSKY90RGBW all alimentazione 230V 50Hz collegare l uni
30. m impurities caused by dust smoke or other particles to ensure that the light is radiated at maximum brightness For cleaning disconnect the main plug from the socket Use a soft clean cloth moistened with a mild detergent Then carefully wipe the part dry For cleaning other housing parts use only a soft clean cloth Never use a liquid it might penetrate the unit and cause damage to it Warning we strongly recommend internal cleaning to be carried out by qualified personnel 4 2 TROUBLESHOOTING Problems Possible causes Checks and remedies Nomains supply Check the power supply voltage Dimmer fader set to 0 Increase the value of the dimmer channels Fixture does not light up Al color faders set to 0 Increase the value of the color channels Faulty LED Replace the LED board Faulty LED board Replace the LED board E Dirty lens assembly Clean the fixture regularly General low light intensity Misaligned lens assembly Install lens assembly properly No power Check for power on power outlet Fixture does not power up Loose or damaged power cord Check power cord Faulty internal power supply Replace internal power supply Wrong DMX addressing Check control panel and unit addressing Fixture does not respond to DMX Damaged DMX cables Check DMX cables Bouncing signals Install terminator as suggested Contact an authorized service center in case of technical problems or not reported in the ta
31. n 111 130 3 BLUE R Red 100 Green Up Blue Up 131 150 0 100 000 255 Red Down Green Down Blue 100 151 170 4 WHITE Red 100 Green 100 BI 100 Wh100 171 200 0 100 000 255 White 1 3200K 201 205 16 ARCSKYSORGBVV CH Function in ARCFULL mode Value CH Function in SPECIAL mode Value White 2 3400K 206 210 BLUE White 3 4200K 211 215 0 100 000 255 White 4 4900K 216 220 WHITE White 5 5600K 221 225 5 midi Dios 5 White 6 5900K 226 230 White 7 6500K 231 235 COLOR MACRO White 8 7200K 236 240 77 1751 White 10 8500K 246 250 Red Down Green 100 Blue 0 96 031 050 STROBE Red 0 96 Green Down Blue 100 96 071 090 6 000 009 Red Up Green 0 Blue 100 96 091 110 Strobe Slow Fast 010 255 Red 100 Green 0 Blue Down 111 130 Red 100 Green Up Blue Up 131 150 DIMMER SPEED Red Down Green Down Blue 100 151 170 Off 000 009 Red 100 Green 100 BI 100 Wh100 171 200 7 Speed 1 Fastest 010 069 White 1 3200K 201 205 Speed 2 070 129 White 2 3400K 206 210 Speed 3 130 189 White 3 4200K 211 215 Speed 4 Slowest 190 255 White 4 4900K 216 220 White 5 5600K 221 225 White 6 5900K 226 230 White 7 6500K 231 235 SOLID White 8 7200K 236 240 White 9 8000K 241 245 White 10 8500K 246 250 CH Function in SOLID mode Value White 11 10000K 251 255 RGB amp MASTER DIMMER STROBE 1 0 100 000 255 7
32. ntry in which the fixture s being used Install the fixture in a well ventilated place The minimum distance between the fixture and surrounding walls must be more than 50 cm and the air vents at the housing must not be covered in any case Keep any inflammable material at a safe distance from the fixture Shields lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired The lamp LED shall be changed if it has become damaged or thermally deformed Never look directly at the light beam Please note that fast changes in lighting e g flashing light may trigger epileptic seizures in photosensitive persons or persons with epilepsy ARCSKYSORGBW 3 GENERAL INFORMATION Shipments and claims The goods are sold ex works and always travel at the risk and danger of the distributor Eventual dam age will have to be claimed to the freight forwarder Any claim for broken packs will have to be forwarded within 8 days from the reception of the goods Warranty and returns The guarantee covers the fixture in compliance with existing regulations You can find the full version of the General Guarantee Conditions on our web site www musiclights it Please remember to register the piece of equipment soon after you purchase it logging on www musiclights it The product can be also registered filling in and sending the form available on your guarantee certificate For all purpose
33. on to the main network of electric distribution must be carried out by a qualified electrical installer Check that the main frequency and voltage correspond to those for which the unit is designed as given on the electrical data label This unit is not for home use only professional applications Never use the fixture under the following conditions in places subject to vibrations or bumps in places with a temperature of over 45 Make certain that no inflammable liquids water or metal objects enter the fixture Do not dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales point for an inspection or contact the manufacturer directly If the unit is to be put out of operation definitively take it to a local recycling x plant for a disposal vvhich is not harmful to the environment VVarnings and installation precautions If this device will be operated in any way different to the one described in this manual it may suffer damage and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock etc Before starting any maintenance work or cleaning the projector cut off power from the main supply Always additionally secure the projector with the safety rope When carrying out any work always com ply scrupulously with all the regulations particularly regarding safety currently in force in the cou
34. rasmettitore W DMX fig 9 W DMX Fig 9 Impostare mediante controller esterno ARCMAT la modalit di funzionamento DMX e l indirizzo DMX Aprire il coperchio di protezione per accedere alla scheda ricevente W DMX Quindi posizionare en trambi i dip switches alla posizione ON fig L indicatore LED rosso si illuminer Tenere premuto il tasto RESET button finch LED verde non si spegne In questo modo il ricevitore W DMX risulta acceso e completamento resettato ovvero disponibile per essere accoppiato con un trasmettitore W DMX Fig 10 ARCSKYSORGBW 19 4 MANUTENZIONE 4 1 MANUTENZIONE E PULIZIA DEL SISTEMA OTTICO Durante gli interventi assicurarsi che l area sotto il luogo di installazione sia libera da personale non qualificato Spegnere l unit scollegare il cavo di alimentazione ed aspettare finch l unit non si sia raffreddata Tutte le viti utilizzate per l installazione dell unit e le sue parti devono essere assicurate saldamente e non devono essere corrose Alloggiamenti elementi di fissaggio e di installazione soffitto truss sospensioni devono essere total mente esenti da qualsiasi deformazione cavi di alimentazione devono essere in condizione impeccabile e devono essere sostituiti immediata mente nel momento in cui anche un piccolo problema viene rilevato Si dovrebbe procedere ad intervalli regolari alla pulizia della parte frontale per asportar
35. rchWork ARCHITECTURAL CONCEPT ARCSKY90RGBW OUTDOOR FIXTURE NN mili Manuale Utente User Manual OCC TOI 1O 30 05 CO 101 101 101 DI Music amp Lights S r l si riserva ogni diritto di elaborazione in qualsiasi forma delle presenti istruzioni per l uso La riproduzione anche parziale per propri scopi commerciali vietata AI fine di migliorare la qualit dei prodotti la Music amp Lights S r l si riserva la facolt di modificare in qualunque momento e senza preavviso le specifiche menzionate nel presente manuale di istruzioni Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione Manuali sul sito www musiclights it REV 001 07 13 ARCSKYSORGBW INDICE Contenuto dell imballo Sicurezza Avvertenze generali Attenzioni e precauzioni per l installazione Informazioni generali 1 Introduzione 1 1 Descrizione 1 2 Specifiche tecniche 1 3 Elementi di comando e di collegamento 2 Installazione 1 Montaggio N Funzioni e impostazioni 2 Impostazione base 3 Struttura menu 4 Configurazioni canali 5 Modalit DMX FN 6 Impostazione dell indirizzo di start 7 Tabella canali DMX 8 Modalit Static 9 Funzione dimmer 10 Calibrazione bianco 11 Funzioni speciali 12 Funzionamento wireless DMX UJ UJ C UJ WLW UC UJ WWW CO W b Manutenzione 1 Manutenzione e pulizia del sistema
36. s the va lidity of the guarantee is endorsed solely on presentation of the guarantee certificate Music amp Lights will verify the validity of the claim through examination of the defect in relation to proper use and the actual validity of the guarantee Music amp Lights will eventually provide replacement or repair of the products de clining however any obligation of compensation for direct or indirect damage resulting from faultiness 4 ARCSKYSORGBW 1 INTRODUCTION 1 1 DESCRIPTION ArcSKY90 is a high power outdoor fixture the first LED based luminaire that can be compared to a 1500W HID large area color washer The lights source is composed by 90 3W LEDs offering an outstanding efficiency over the whole chromatic scale The structure has been designed to grant IP66 protection rate making arcSKY a reliable fixture for large size outdoor architectural projects under any weather condition The wide range of optional optics allows to pass from a 6 narrow beam to 55 flood diffusion providing the lighting designer an indispensable tool for their projects This incredible fixture offers an extremely green solution for large outdoor application its 310W of max power consumption allows to cut the environmental impact of projects 1 2 TECHNICAL SPECIFICATIONS ARCSKY90RGBW LED source 90x3W 24R 246 24B 18W Lumen 8500lm Peak intensity 260000cd 6 Input voltage AC 100V 240V Max power 310W Optics 30 6