1. L Attacchi idraulici 40 115 Water connections o 1 2 9 o o oQ o Imbuto raccolta condensa o0 N Condensation drain funnel 80 Il N el T m A m LO Zoccoli accessorio y 1N Feet optional Zoccolone ripresa aria con griglia Air intake feet support with grill Bacinella ausiliaria accessorio 20 Auxiliary drain pan optional N Versioni con mobile Versioni senza mobile I _ Versions with cabinet Versions without cabinet 520 mm H1 450 mm a H1 450 ese se mm mm Taglia Size VE i 93P 103P 113P__123P_ DA ss sa Li uh Dimensioni principa li Man dimensions 1 000 1 200 1 200 1 400 1 025 1 225 1 225 1 425 UNITA 2 TUBI 1 batteria 2 PIPES UNITS 1 coil Limite funzionam nferiore Lower working limit Q7 4 1 RIDUZIONE PORTATA ARIA Coefficienti che definiscono le curve Portata Aria Pressione statica alle 3 velocit Max Med Min AIR FLOW REDUCTION Coefficients defining the Air flow Static pressure diagrams 0 47 0 47 0 47 0 47 at 3 speed Max Med Min 0 38 0 38 0 37 0 37 0 24 0 24 0 35 0 35 ESP Pa mai 86 Pa 86 Pa 86 Pa 86 Pa 98 Pa 98 Pa 103 Pa 103 Pa 113 Pa 113 Pa 115
2. request e Modelofthe unit and Identification code e Technical data and Wiring diagram Trasporto Ricevimento Movimentazione 7ransport Heceipt Handling trasporto deve avvenire con le seguenti precauzioni The transport must be done according to the following indications Adeguato bloccaggio sul pianale del camion gt Packages mut be securely fixed at truck s floor gt Protezione del carico con telone gt Packages mut be covered L unit viene spedita trasportata e consegnata racchiusa in un apposito The unit hasa special safety packing for transport and delivery which must be imballo di protezione che deve essere mantenuto integro fino al kept in good conditionstill the unit is positioned on the installation place posizionamento sul luogo di installazione Make sure that the unit has all its parts as specified in the order Controllare che l unit sia completa nelle sue parti come da ordine Check if there are any damages and if the unit abbreviation is the same as Controllare che non vi siano danni e che la sigla dell unit corrisponda al the one of the ordered model modello ordinato Every unit is factory tested before shipment therefore if there are damages Ogni unit viene collaudata in fabbrica prima della spedizione quindi se vi report them immediately to the carrier sono stati danni avvisare immediatamente il trasportatore Shipping unloading and handling of the goods are
3. iaia 8 Ricerca guasi Howto detectiallureS i aaa aaaea 9 Resistenze eletmehe Hec mical heaters irsinin aai aaa aaa aa aaa aaar aai aaah aoaaa Anaan aaan aaa aiara haa Aana iin aana 9 Dati tecnici ventilconvettori con motore asincrono Technical data of fan coils with asynchronous motvor 10 Dati tecnici ventilconvettori con motore brushless Technical data of fan coils with brushless motor 11 Plenum per versioni ad incasso Unit senza mobile Plenum for concealed versions unit without cabinet 12 Chiusure posteriori ed inferiori per versioni con mobile Back and bottom closing panel for versions with cabinet 12 Pannelli per montaggio unit incasso su nicchia Panels for units to be installed in a 13 Dat Tecnici Battene Coils lechnical Data a cuir ccu rs co a iaaa a aaa Ra 14 Osservazioni Remarks Ai fini di un utilizzo corretto e sicuro dell unit l installatore l utente ed il manutentore per le rispettive competenze sono tenuti ad osservare scrupolosamente quanto indicato nel presente manuale Conservare questo libretto in luogo asciutto per evitare il deterioramento per alme
4. 1 alla velocit del ventilatore desiderata permettendo cosi di regolare la potenzialit termica dell unit Comando Se il comando dotato di termostato di minima temperatura acqua posizionare il deviatore Estate Inverno 2 sulla posizione INVERNO II ventilatore funziona quando la temperatura dell acqua superiore a circa 40 Comando C D E Se il comando dotato di termostato ambiente TA dotato di termostato ambiente termostato di minima temperatura acqua TA TM posizionare il deviatore Estate Inverno 2 sulla posizione INVERNO ed agire sulla manopola di regolazione 3 impostando la temperatura desiderata Il ventilatore funziona quando la temperatura dell aria scende al di sotto del valore impostato Comando E Qualora sia prevista la resistenza elettrica accessorio l interruttore 4 abilita il funzionamento della resistenza elettrica Posizionare l interruttore 4 su TP PP PPM HY HA A JJ MAP MM resistenza elettrica ili lectrical heater TM electnca aM nw n ay m m Comando Comando Control Control Itis recommended to make the unit work at the maximum speed for a few hours once installed or in case it hadn t been working for a long time 1 12 ON FUNZIONAMENTO IN RAFFREDDAMENTO ESTATE Comando A B C D E Posizionare il commutatore OFF 3 velocit 1 alla velocit del
5. operazioni di manutenzione almeno una volta all anno Verifica parte elettrica Verificare tutta l apparecchiatura elettrica ed in particolare il perfetto serraggio delle connessioni elettriche Verifica del serraggio di tutti i bulloni dadi e flange che le vibrazioni avrebbero potuto allentare Verificare che il motore non presenti tracce di polvere sporcizia o altre impurit Verificare periodicamente che funzioni senza vibrazioni o rumori anomali che l ingresso del circuito di ventilazione non sia ostruito con conseguente possibilit di surriscaldamento degli avvolgimenti Verificare che la coclea del ventilatore sia libera da sporcizia e qualunque corpo estraneo YEARLY C HEC KS In orderto grant the unit always the best performance and upkeep out timely maintenance operations at least once a year Remember that maintenance operations are to be carried out by qualified personnel only Electrical equipment check Check all the electrical apparatus and in particularthe tightness of the electrical connections Check the tightness of all the nuts bolts and flanges which may have been loosened by vibrations Check there are no traces of dust dirt or other impurities on the motor Periodically check that it operates without vibrations or abnormal noise that the ventilation circuit inlets are not obstructed causing consequently the possibility of motor winding overheating Checkthatthe fan scroll isfree
6. Water connections 1 2 02 2 1 2 1 2 172 1 2 1 2 Batteria per Riscaldamento Heating coil Diametro int tubi Internal diameter tubes mm 9 9 9 9 9 9 9 9 9 9 9 9 Diametroest tubi Externaldiametertubes 10 10 10 10 10 10 10 10 10 10 10 10 Geometria Shape mmxmm 25x25 25x25 25x25 25x25 25x25 25x25 25x25 25x25 25x25 25x25 25x25 25x25 Superficie frontale Front surface m2 0 08 0 08 0 12 0 12 0 16 0 16 0 20 0 20 0 24 0 24 0 28 0 28 Spessore Thichness mm 25 25 25 25 25 25 25 25 25 25 25 25 Tubi totali Total tubes No 8 8 8 8 8 8 8 8 8 8 8 8 Contenuto acqua Water content 0 20 0 20 0 31 0 31 0 41 0 41 0 51 0 51 0 61 0 61 0 71 0 71 Ranghi Rows No 1 1 1 1 1 1 1 1 1 1 1 1 Attacchi idraulici Water connections 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 AIR CONDITIONING Via Gettuglio Mansoldo La Macia 37040 Arcole Verona Italy Tel 39 045 76 36 585 r a Fax 39 045 76 36 551 r a www maxa it e mail maxa maxa it dati riportati nella presente documentazione sono solamente The data indicated in this manual is purely indicative The ma indicativi Il costruttore si riserva la facolt di apportare in qualsiasi nufacturer reserves the right to modify the data whenever it is momento tutte le modifiche ritenute necessarie considered necessary
7. signals as their disrepect can cause damage to the unit and or person orobjects For any malfunctions not mentioned in this manual contact the local After sales Service immediately Always keep this handbook with the unit This manual isan integral and essential part of the product and must be given to the user Should the unit be sold or transfered to another owner please ensure that the manual remains with the unit for use by the new ownerand or installer The Manufacturer declines all responsibility for any damage whatsoever caused by improper use of the unit and a partial or superfic ial ac quaintance with the information contained in this bulletin The technical data styling X characteristics components and accessories reported in this manual are not binding The Manufacturer reserves the right to make changes at any time that are considered necessary to improve the product The lawful references standards or technical rules mentioned in this manual are presented merely for the sake of information and should be consdered valid as of the date this manual is printed If new regulations or amendments to curent laws go into effect this will not obligate the Manufacturer in any way with regard to others The Manufacturer is responsible for ensuring that its product conforms to the laws directives and construction standards in force at the time the product is sold Knowledge and compliance with legal regulations and standards regard
8. 36 0 31 0 31 0 83 0 76 0 72 0 62 0 60 0 45 0 45 0 69 0 48 0 48 0 51 0 51 0 36 0 36 0 38 0 32 0 30 0 27 0 26 0 19 0 19 0 64 0 34 0 32 0 31 0 30 0 23 0 23 0 53 0 25 0 25 0 29 106Pa 10 20 81 x0 20 81Pa x020 85Pa x0 20 85Pa x0 20 83Pa x0 20 83Pa x0 20 102Pa 10 20 73Pa x0 19 74Pa x0 19 81Pa x0 20 82Pa x0 20 79Pa x0 20 79Pa x0 20 90Pa x0 18 64Pa x08 64Pa x0 18 68Pa x0 18 68Pa x0 18 63Pa x0 17 amp 3Pa 0 17 080 075 0 70 0 65 0 60 055 050 0 45 040 035 0 30 025 0 20 0 72 0 68 0 64 Potenzialit termica Heating capacity Dati tecnici riferiti alle seguenti condizioni Unit Standard Pressione atmosferica 1013 mbar Alimentazione elettrica 230Vac 1Ph 50Hz 1 Dati elettrici Valore MAX di targa motore valore di riferimento per progettazione impianto elettrico Tutti i Dati elettrici rilevati con Wattmetro Jokogawa WT110 2 Portata aria e Press statica Valori nominali rilevati con cassone rif norme AMCA210 74 fig 12 e condotto diaframma rif norme CNR UNI10023 2 Curve portata Max segnale 10Vdc Med segnale nom 10 taglia 900 1000 x0 8Max Min segnale 3Vdc rif SW Tensione cost rapporti cost 3 Rese Frigorifere e Termiche Valori calcolati da SW e dati rilevati in camera calorimetrica rif norme UNI 7940 parte 1 2 UNI EN 1397 2001 MB Motore Brushless Temperatura ari
9. 9 9 9 9 9 9 9 9 9 9 9 9 Diametroest tubi Externaldiametertubes 10 10 10 10 10 10 10 10 10 10 10 10 Geometra Shape mmxmm 25x22 25x25 25x22 25x25 25x22 25x25 25x22 25x25 25x22 25x25 25x22 25x25 Superficie frontale Front surface 0 08 0 08 0 12 0 12 0 16 0 16 0 20 0 20 0 24 0 24 Spessore Thichness mm 66 75 66 75 66 Tubi totali Total tubes No 24 24 24 24 24 24 24 24 24 Contenuto acqua Water content Ranghi Rows NO 3 3 3 3 3 3 3 3 3 3 3 3 Attacchi idraulici Water connections 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Attacchi idraulici batteria Gas femmina Female gas water coil connections MODELLO MODEL 13 ChE NERIS a oo Batteria per Condizionamento Cooling coil Diametro int tubi Internal diameter tubes mm 9 9 9 9 9 9 9 9 9 9 9 9 Diametroest tubi Externaldiametertubes 10 10 10 10 10 10 10 10 10 10 10 10 Geometria Shape mmxmm 25x22 25x25 25x22 25x25 25x22 25x25 25x22 25x25 25x22 25x25 25x22 25x25 Superficie frontale Front surface 0 08 0 08 0 12 0 12 0 16 0 16 0 20 0 20 0 24 0 24 0 28 0 28 Spessore Thichness mm 66 75 66 75 66 75 66 75 66 75 66 75 Tubi totali Total tubes No 24 24 24 24 24 24 24 24 24 24 24 24 Contenuto acqua Water content 0 61 0 66 0 92 0 98 1 22 1 28 1 53 1 59 1 83 1 89 2 14 2 20 Ranghi Rows NO 3 3 3 3 3 3 3 3 3 3 3 3 Attacchi idraulici
10. Qa me h i Qa 103 0 20 103 x0 20 106Pa x0 20 Limite funzionam superiore ESP xQa Med 98 x0 20 99Pa x0 20 102Pa x0 20 Up per worki ng limit ESP x Qa 89Pa x0 19 89Pa x0 19 90Pa x0 18 UNITA A 4 TUBI 2 batteria 4 PIPES UNITS 2 coils Limite funzionam inferiore a Lower working limit EP 0Pa e 1 00 1 00 9 gt Min 0 69 0 64 0 59 t Max 1 39 1 28 1 16 5 20 0 91 0 91 0 89 V E Min 0 62 0 58 0 53 8 E Max 1 24 1 15 1 03 Coefficienti che definiscono le curve 0 56 0 92 0 47 Portata Aria Pressione statica Max 1 03 0 95 0 90 alle 3 velocit 60Pa 0 67 0 67 0 69 AIR FLOW REDUCTION Min 0 46 0 43 0 41 Coefficients defining the E 0 78 0 72 0 69 Air flow Static pressure diagrams at 3 speed Max Med Min 80 Med 0 51 0 51 0 53 5 0 35 0 32 0 32 LIPS ESP Pa Qa me h i ESP Max 103 0 20 103Pa 0 20 106Pa x0 20 Limite funzionam superiore ESP xQa Med 97 x0 20 98 x0 20 101Pa x0 20 Up per worki ng limit ESP x Qa 89Pa x0 19 89Pa x0 19 90Pa x0 18 3 RIDUZIONE POTENZIALIT FRIGORIFERA TERMICA in funzione della riduzione portata aria 3 COOLING HEATING CAPACITY REDUCTION depending on air flow reduction Portataaria Airfom_ 150 140 Potenzial Frigorifera Totale Total Sen
11. UE EUR NuUa CERE R COE ONU n 5 Installazione Posizionamento unit Installation Unit loc ation 11 1 Leere rer rrr rure enne e enu nana aaa u uana anas assem nnn n uuu u uuu nnna 5 Installazione Collegamento idraulico Installation Water supply connections 5 Installazione Scarico condensa Installation Drain pipe 1 11111ee ee leiieee eere eene eee n unen nana aaa u unu aaa u uu nnn rusa aaa u uuu 6 Installazione Collegamento elettrico Installation Electric al connections iii 6 Norme per l utente Funziona mento Information for the user Operating 7 Norme per l utente Usi impropri Information forthe user Improper use 7 Norme per l utente Manutenzione Pulizia Information for the user Maintenance Cleaning 11 8 Norme per l utente Assistenza Information for the user After sales service ee eeeieeee eere rennen enne enn ana nn 8 Norme per l utente Ricambi Information for the user Spare parrts 1 111eeeee eere enis eene eene n anna aaa u unu u uaa aaa R unnm rua a uuu uuu uu 8 Smaltimento Waste disposal
12. ventilatore desiderata permettendo cosi di regolare la potenzialit frigorifera dell unit Comando Se il comando dotato di termostato di minima temperatura acqua TM posizionare il deviatore Estate Inverno 2 sulla posizione ESTATE il termostato TM viene by passato Comando C D E Se il comando dotato di termostato ambiente TA o dotato di termostato ambiente termostato di minima temperatura acqua TA TM posizionare il deviatore Estate Inverno 2 sulla posizione ESTATE ed agire sulla manopola di regolazione 3 impostando la temperatura desiderata Il ventilatore funziona quando la temperatura dell aria supera il valore impostato Comando E Qualora sia prevista la resistenza elettrica accessorio lasciare l interruttore 4 in posizione 0 OFF NOTA Per un controllo della temperatura ambiente preciso ed affidabile si raccomanda di mantenere il motore sempre acceso e controllare la temperatura tramite la regolazione di elettrovalvole a 2 OPERATING IN HEATING MODE WINTER Contro lA D E Position the OFF speed switch 1 on the required fan speed in orderto adjust the heating capacity of the unit Control If the control is equipped with water low temperature thermostat TM position the Winter Summer switch 2 on WINTER mode The fan will start working when the water temperature reaches a temperature of approx 40
13. 0 2100 4 900 2 300 5 900 3 000 6 700 3 400 7 300 3 700 8 600 4 400 i i 10 400 4 100 11 500 4 500 13 100 5 900 14 200 6 300 15 200 6 700 17 500 7 800 424 m h 22 dB A 10W 0 09A 514 m8 h 24 dB A 11W 536 m h 25 dB A 11W 0 09A 4 500 1 900 5 700 2 400 6 700 2 900 7 100 3 100 Portata aria Air flow Range 520 130 610 150 1 000 220 1 150 300 1 230 330 Livelli sonori Sound Levas Range dB A 45 10 47 10 45 12 46 46 11 Ass el valori funzion Current input operating values Range 48 6W 0 32 0 07A 24 6W 0 36 0 07A 65 6W 0 44 0 07A 74 6W 0 49 0 08A 736W 0 48 007A Dimensioni principali Main dimensions Motori Ventilatori Motors Fans No No Assorb Elettr di targa Label curentinput MAX 1 UNITA A 2 TUBI 1 batteria 2 PIPES UNITS 1 coil Limite funzionam inferiore mmm D Lower working limit ESP OPa MB tipo ie 9 gt Min 0 65 0 60 0 57 t Max 1 32 1 22 1 11 20 Pa Med 0 91 0 91 0 89 V Min 0 59 0 55 0 51 2 118 1 09 0 99 Coefficienti che definiscono le curve Min 0 53 0 49 0 45 Portata Aria Pressione statica E Max 0 98 0 90 0 86 alle 3 velocit Max Med Min 60Pa 0 67 0 67 0 69 AIR FLOW REDUCTION 0 44 0 41 0 39 the vai n dui iu Ir IOW pressure aiagrams at 3 speed Max Med Min 80 Pa Med 0 51 0 51 0 53 5 0 33 0 31 0 30 LIPS 5
14. C D E If the control is equipped with room thermostat TA or is equipped with room thermostat c water low temperature thermostat TA position the Winter Summer switch 2 on WINTER mode and work on the adjustable knob 3 and place on the required temperature The fan will start working when the airtemperature drops underthe pre set value ControlE Incase that the electrical heater is installed optional the switch 4 activates the electrical heater Position the switch 4 on 1 1 ON OPERATING IN COOLING MODE SUMMER Control A B C D E Position the OFF speed switch 1 on the required fan speed in orderto adjust the cooling capacity of the unit Control B if the control is equipped with water low temperature thermostat TM position the Winter Summer switch 2 on SUMMER mode by pass of the thermostat TM Contnl C D E If the control is equipped with room thermostat TA or is equipped with room thermostat 4 water low temperature thermostat TA 4 TM position the Winter Summer switch 2 on SUMMER mode and work on the adjustable knob 3 and place on the required temperature The fan will start working when the airtemperature reachesthe pre set value Control E case that the electrical heater is installed optional position the switch 4 on 0 0 NOTE To reach an exact and reliable room temperature regulation we recommend to keep the motor alway
15. EL CAN CONTROL ONE SINGLE UNIT ONLY NOTE To control more than 1 unit or 1 unit with 2 motors it is recommended to keep the electrical power supply of the different motors SEPARATE AND INDEPENDENT FROM EACH OTHER To do so it is recommended to install 3 relays one each speed by independent contacts one contact each motor to be controlled or install the INTERFACE CHART accessory this way should any inconvenience happen to any of the fan motors it would not involve nor interfere with the others For installation of control panel choose an area where the max and min room temperature limit is respected 0245 C lt 85 U R Do not install the control panel on metallic walls if the metallic wall is not permanently earthed Accessories Water low temperature themnostat MM The water low temperature thermostat automatically shuts down the ventilation when the inlet watertemperature to the coil isbelow 40 C in heating mode Winter mode Norme per l utente Funzionamento Information for the user Operating INVERNO modalit Riscaldamento WINTER Heating mode R ESTATE modalit Raffreddamento SUMMER Cooling mode Comando Comando Comando Control Control Control Si raccomanda di far funzionare l unit alla velocit massima per alcune ore appena montata e dopo lunghi periodi di inattivit FUNZIONAMENTO IN RISCALDAMENTO INVERNO Comando A C D E Posizionare il commutatore OFF 3 velocit
16. IL GETTO D ARIA Orientare le alette in modo che il flusso d aria non investa direttamente le persone creando sensazioni di disagio CORRECTAIR ETPOSITIO NING Adjust the fins so that the air flow is not aimed directly at person q PER PULIRE L UNIT Non indirizzare getti d acqua S a V sull unit Pu causare scosse elettriche danneggiarla Non usare acqua calda sostanze abrasive o solventi 2 per pulire l unit usare un panno soffice TO CLEAN THE UNIT Do not splash water on the unit lt could result in electrical shock or damage to the unit Do no use hot water abrasive powders or strong solvents to clean the unit use a soft cloth NON COPRIRE Ee L UNIT CON OGGETTI O TENDAGGI CHE OSTRUISCANO ANCHE PARZIALMENTE IL FLUSSO DELL ARIA DO NOTCOVER THE UNIT WITH ECTS OR CURTAINS WHICH MAY PARTIALLY OBSTRUCTAIR FLOW ATTENZIONE Durante il funzionamento non posare oggetti o panni ad asciugare sulla griglia di uscita aria ne ostruirebbero il passaggio con pericolo di danneggiamento dell unit ATIENTION When the unit is running do not place any object or cloths to dry on the air outflow grill they would obstruct the flow and damage the unit Norme per l utente Manutenzione Pulizia nformation for the user Maintenance Cleaning Queste unit sono costruite con tecnologie moderne che ne assicurano l efficienza ed il funzionamento nel tempo essenziale stabilire e seguire un regolare p
17. IN 1 2 to isolate the coil from the rest of the circuit in the event of special maintenance Connect the inlet water with a shut off valve and the outlet with a balancing valve orinstalled 2 shut off valves Fita breather valve above and a discharge valve below Attacchi idraulici dell unit 1 2 Gas femmina The water coils are tested at a pressure of 30 Bar and therefore they can operate at a Unit s water connections 1 2 Female gas maximum pressure of 15 Bar Position and support tubeson unit exterior by bracketsto relieve the coil of excessive weight Install antifreeze devices If the unit is installed in particulady cold rooms fill out the watertank during long rest periods Installazione Scarico condensa nstallation Drain pipe Si consiglia di isolare adeguatamente le tubazioni dell acqua per evitare gocciolamenti durante il funzionamento in raffreddamento La rete di scarico condensa deve essere opportunamente dimensionata e le tubazioni posizionate in modo da mantenere lungo il percorso una adeguata pendenza min 3 e non deve presentare tratti ascendenti o strozzature per consentire un regolare deflusso opportuno che lo scarico condensa sia sifonato Lo scarico condensa va collegato alla rete di scarico pluviale Non utilizzare scarichi di acque bianche o nere rete fognaria per evitare possibili aspirazioni di cattivi odori verso gli ambienti nel caso di evaporazione dell acqua contenuta nel sif
18. K or NO7V K insulated cables with 300 500 V piped orducted All cableshave to be piped orducted until they are not placed inside the terminal board of the unit The cables coming out of the pipe duct have not to be subjected to stretch or twist They must be protected from weathering Stranded cables shall only be used in connection with terminating sleeves Make sure that all individual cables are correctly inserted in the seeve ELEC TRIC AL C ONNEC TIO NS Cany out the electrical connections according to the wiring diagram MAKE REFERENC E TO THE WIRING DIAGRAM INCLUDED IN EVERY UNIT The use of adapters multi plugs and or extension cords is not permitted for unit main power supply It is the installer s responsibility to install the unit as close as possible to the general power switch To prevent short circuits the unit should be connected to the electric supply line by means of an omnipolar magnetothermic switch with a minimum contact opening of 3 mm see electrical absorbing schedule to chose the right switch An omnipolar switch is a Double pole isolating switch i e a switch capable of disconnecting both on phase and neutral This means that when the switch is opened both contacts are disconnected The omnipolar switch or the plug connection by means of cable and plug must be mounted in places easy to reach ELECTRICAL ABSORPTION Make reference to the electrical absorption written on the unit label EACH CONTROL PAN
19. Pa 115 Pa 119 Pa 119 Pa LES Qa x m3 h x 0 20 x 0 20 x 0 20 x 0 20 x 0 20 x 0 20 x 0 20 x 0 20 x 0 20 x 0 20 x 0 20 x 0 20 x 0 20 x 0 20 Limite furzionam superiore ESP Pa 75 Pa 75 Pa 76 Pa 76 Pa 90 Pa 90 Pa 97 Pa 97 Pa 109 Pa 109 Pa 108 Pa 108 Pa 113 Pa 113 Pa x m3 h 0 19 0 19 0 19 x 0 19 0 19 x 0 19 x 0 19 x 0 19 x 0 20 x 0 20 0 19 0 19 x 0 19 x 0 19 Upper working limi ESP Pa 56 Pa 56 Pa 57 Pa 57 Pa 68 Pa 68 Pa 80 Pa 80 Pa 99 Pa 99 Pa 98 Pa 98 Pa 111 Pa 111 Pa Qa x m3 h x 0 16 0 16 0 16 X 0 16 x 0 17 x 0 17 x 0 18 x 0 18 0 19 0 19 x 0 18 x 0 18 0 19 x 0 19 UNITA A 4 TUBI 2 batterie 4 PIPES UNITS 2 coils Limite funzionam nferiore Lower working limit 9 4 1 RIDUZIONE PORTATA ARIA Coefficientiche definiscono le curve Portata Aria Pressione statica alle 3 velocit Max Med Min AIR HOW REDUCTION Coefficients defining the Air flow Static pressure diagrams at 3 speed Max Med Min ESP Pa 86 Pa 86 Pa 86 Pa 86 Pa 98 Pa 98 Pa 104 Pa 104 Pa 113 Pa 113 Pa 115 Pa 115 Pa 119 Pa 119 Pa Max LES Qa x m3 h x020 x020 x020 x020 xo20 xo20 x020 em ESP 75Pa 75Pa 76Pa 76Pa 90Pa 90Pa 96Pa nore 108Pa 108 Pa 4 114 Pa Limite funzionam rior i SUM x019 xois xaiw xoro xo019 xoi xo19 xoz xo019 x020 ppe
20. UNI EN 1397 2001 standards 10 Dati tecnici ventilconvettori con motore brushless Technical data of Fan coils with brushless motor Attacchi idraulici Water connections Imbuto raccolta condensa Condensation drain funnel Sc arico condensa Drain pipe Zoccoli So I Feet optional LA Zoccolone ripresa aria con griglia Air intake feet support with gril Bacinella ausiliaria accessorio 20 Auxiliary drain pan optional Versioni con mobile Versioni senza mobile Versions with cabinet Versions without cabinet H 520 mm H1 450 mm S 220 mm 51 215 mm Taglia Size VEMB 8 53 8 _ 83 B 103 Portata aria Livelli sonori Air flow Sound Levels Assorb Hettr valori funzion Curentinput operating values RANGE 10 1Vdc Potenz frigor totale Total cooling cap Range W Potenza termica Heating copacdity Range W 240 m3 h 23 dB A 9W 0 09A 1 700800 2 200 1 100 Prestazioni di funzionamento attese equilibrio Prestazioni unit prestazioni richieste Expected operating conditions balance Units performances required performances 285 m h 26 dB A 9W 0 10A Prestazioni MAX rif segnale 10Vdc MIN rif 1Vdc per segnali 1Vdc l unit rimane OFF MAX performances ref 10Vdc signal MIN ref 1Vdc for signal lt 1Vdc the unit is OFF 2 700 1 400 3 100 1 600 450
21. a 230V comandi remoti ecc Verificare che la rete sia monofase 230V 1Ph 50Hz e che la tensione di alimentazione rientri nei limiti Vmin gt 195 Vmax lt 265 Il funzionamento dell unit con tensioni non comprese nei limiti suddetti fa decadere la garanzia Assicurarsi che l impianto elettrico sia in grado ad erogare oltre alla corrente di esercizio richiesta dall unit anche la corrente necessaria per alimentare elettrodomestici ed unit gi in uso WVERIHC ARE IL COLLEGAMENTO DELLA MESSA A TERRA La sicurezza elettrica dell unit raggiunta soltanto quando la stessa correttamente collegata ad un efficace impianto di messa a terra eseguito come previsto dalle vigenti norme di sicurezza Al momento del collegamento il cavo di terra sia pi lungo di quelli sotto tensione Sar l ultimo cavo a strapparsi in caso venga accidentalmente tirato il cavo di alimentazione e rimarr quindi assicurata una buona continuit di terra C ARATIERISTIC HE DEI CAVI DI COLLEGAMENTO Eseguire il collegamento dell unit e di tutti i suoi accessori con cavi di sezione adeguata alla potenza impegnata e nel rispetto delle normative locali La loro dimensione deve comunque essere sufficiente per realizzare una caduta di tensione in fase di avviamento inferiore al 376 di quella nominale Usare cavi tipo HO5V K oppure NO7V K con isolamento 300 500 V incassati in tubo o canalina Tutti i cavi devono essere incassati in tubo o canalina finch non
22. a in ingresso 27 C b s 19 5 C b u Temperatura acqua in ingresso uscita 70 C 60 C 0 74 0 70 0 66 062 0 58 0 53 Technical data referto the following conditions Standard unit Atmospheric pressure 1013 mbar Power supply 230Vac 1Ph 50Hz 1 Electrical data MAX value of motor label reference value for the electrical system design All the elect data measured with Wattmeter Jokogawa WT110 2 Air flow and Static pressure Nominal data measured with casing ref AMCA210 74 fig 12 standards and plenum diaphragm ref CNR UNI10023 standards 2 Air flow curves Max 10Vdc signal Med nominal signal 10 size 900 1000 x 0 8Max Min 3Vdc signal ref SW Constant Voltage constant ratio 3 Cooling and Heating capacities Data calculated by SW and measurements made in calorimetric room ref UNI 7940 part 1 2 UNI EN 1397 2001 standards MB Brushless Motor Air inlet temperature 27 d b 19 5 C b u In out water temperature 70 C 60 C Plenum per versioni ad incasso Unit senza mobile Plenum for concealed versions unit without cabinet Compatibilit tutte le versioni ad incasso senza mobile Compatibility all concealed versions without cabinet Compatibilit Compatibility VE MB 13 23 33 43 53 63 73 83 93P 103P 113P 123 Dimensioni Dimensions L mm 400 600 800 1 000 1 200 1 400 Plenum con attacchi circolari Plenum with spigot
23. ali e cose nei confronti dei quali il costruttore non pu essere considerato responsabile costruttore non pu essere considerato responsabile per eventuali danni derivanti da usi impropri erronei o irragionevoli Thisunit isdesigned to be used forheating cooling purposes only Any different use is not allowed as it may be dangerous Should the unit work in a house where disabled people and or children live it must be placed safely away from their reach Always make sure that the accessdoorto the inside control board stay locked An incorrect installation can cause damages to people animals and property In case of emoneous installation the manufacturer cannot be held responsible for such damages The manufacturercannot be held responsible for such damages by improrer uses emate uses etc Non usare l unit come sostegno per altro macchinario n caso di guasto o cattivo funzionamento dell unit Non lasciare all interno dell unit utensili stracci parti di disattivarla astenendosi da qualsiasi tentativo di ricambio ecc riparazione e chiedere l intervento dell installatore Non lasciare i pannelli di ispezione parzialmente chiusi Dal momento che si decide di non utilizzare pi l unit accertarsi che tutte le viti siano perfettamente serrate si dovranno rendere innocue quelle parti che Non esporre l unit a gas infiammabili potrebbero essere fonti di pericolo Neveruse the unit to support other eq
24. all operations to be trasporto lo scarico e la movimentazione devono essere effettuati con la camed out very carefully in order not to damage goods Try not to use the massima cura per evitare possibili danneggiamenti utilizzando come punto di unit s components as handholds presa unicamente la base della macchina ed evitando di usare come punti When lifting bearin mind that the centre of gravity of the unit may be off centre forza i componenti dell unit Fare attenzione nel sollevamento della unit il cui baricentro pu anche essere fuori asse Yo NON LASCIARE GLI IMBALLI SCIOLTI NON SPOSTARE L UNIT DA SOLI DURANTE IL TRASPORTO SE IL SUO PESO SUPERA I 35 Kg NON BAGNARE NON CALPESTARE DO NOTLEAVE LOOSE PACKAGES DO NOTHANDLE THE UNITALONE DO NOTWET DO NOTTRAMPLE DURING THE TRANSPORT IF ITS WEIGHTIS OVER 35 Kg Stoccaggio in cantiere Sfocking at site Le unit devono essere immagazzinate al coperto The units must be stoc ked inside the building Installazione Posizionamento unit Dsftallation Unit location L INSTALLAZIONE DEVE AVVENIRE NEL RISPETTO DELLE NORME VIGENTI The installation mustbe always compliant with the cunentlocal laws Verificare la corrispondenza dell unit e delle sue caratteristiche tecniche Checkthat the unit and itstechnical characteristics match what is indicated rispetto a quanto previsto dal progetto o da altri documenti by the design orotherdocuments Non la
25. am and electrical connections Excessive noise Air flow too high Reduce air flow Metalcomponents damaged Check state of componentsand replace damaged parts Rotation parts off balance Balance fan impeller The motor fan does not work Current lack Control the power supply With water low temperature thermostat TM has tripped because the temperature has dropped below 40 C in winter mode Control the boiler Make sure that The electrical Switchesand orthermmostats are on the right working position Make sure that No objects obstruct the fan rotation The unit does not heat up as before Hot water supply lack Control the boiler and the hot water pump Wrong setting on control panel See control panel settings Make sure that The airfilter and the coil are clean Make sure that Airdid not enter in the hydraulic circuit check it using provided air vent valve Make sure that The installation is well balanced The boilerisfunctioning The hot waterpump isfunctioning The unit does not c ool up as before Chilled water supply lack Control the chiller and the chilled water pump Wrong setting on control panel See control panel settings Make sure that The airfilter and the coil are clean Make sure that Airdid not enter in the hydraulic circuit check it using provided air vent valve Make sure that The inca Ila tion is well balanced The chiller is functioning The chilled water pump is functio
26. cordance with 98 37 CE Machines directives ex 89 392 amandments 91 368 93 44 CEE 93 68 CEE 73 23 Low Voltage directives EMC 89 336 Electromagnetic Compatibility directives Manufactured and tested unit in accordance with 92 3l CEE 92 59 CEE directives and with EN 292 1 EN 292 2 EN 294 EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 EN 60555 2 EN 60204 1 CEI EN 60335 1 C EI EN 60335 2 40 standards and General Management Simboli di sicurezza Safety symbols ATTENZIONE PERICOLO PERICOLO PERICOLO PERICOLO Pericolo Tensione Togliere Tensione Alta Temperatura Organi in movimento ATTENTION DANGER DANGER DANGER DANGER Danger Power Supply Disc onnect Power Line Hight Temperature Moving parts Earthing Use undercamage Use protective gloves Only Qualified Personnel OBBLIGATORIO OBBLIGATORIO OBBLIGATORIO OBBLIGATORIO Messa a Tena Usare canello Usare guanti protettivi Solo Personale Qualificato VIETATO COMPULSORY COMPULSORY COMPULSORY COMPULSORY FORBIDDEN Prescrizioni di sicurezza Safety measures Nel corso DELL INSTALLAZIONE MESSA IN FUNZIONE USO E MANUTENZIONE delle unit devono essere rispettate le seguenti nome di sic urezza Observe the following regulations when INSTALLING STARTING UP USING AND SERVICING the units L installazione deve essere effettuata in ottemperanza alle vigenti normative del Paese di utili
27. e caratteristiche tecniche di progetto Controllare periodicamente che la parete alettata non presenti ostruzioni al passaggio dell aria se necessario pulirla avendo cura di non danneggiare le alette di alluminio Per la pulizia usare uno scopino o meglio un aspirapolvere Nel caso di installazione in zone con climi particolarmente freddi svuotare l impianto dall acqua in previsione di lunghi periodi di fermata dell impianto SCARICO CONDENSA Durante la stagione estiva controllare che lo scarico condensa non sia ostruito e che la bacinella sia pulita da polvere od altro Eventuale sporcizia potrebbe otturare lo scarico provocando tracimazioni dell acqua di condensa GRUPPO MOTORE VENTILATORE sia i motore sia le ventole ruotano su cuscinetti autolubrificanti e non richiedono manutenzione Accertarsi che la girante sia pulita In caso contrario pulia mediante soffiaggio di aria compressa e comunque in modo da non danneggiare la girante RO UTINE MAINTENANC E TO BE PERFORMED BY THE USER NOTE Adequate maintenance ensures safety and savings It is recommended to out the following operations at the beginning of each cooling and heating season and then at least once every month during operation Cleanthe extemal parts of the unit simply by using a damp cloth AIR ALIER Cleaning every 15 days The cells may be cleaned by a simple flapping or by washing them into water detergent or by using compressed air blast IMPORTANT wh
28. en cleaning the cells make sure that the water air blast is crossing the media in the opposite direction of the one of normal unit operation The blasting over the media must not be too hard or near so to avoid possible damages of the filtering mass If the cells are washed with water detergent dry them up in open airbefore re installation in order not to affect the system efficiency WATER COIL The water coil must be kept in a perfectly good condition to guarantee the technical design features Verify periodically that the finned wall has no obstructionsto airflow if necessary clean it and be careful not to damage the aluminium fins To clean it use a little brush ora vacuum cleaner which is even better If the unit is installed in particular cold rooms fill out the watertank during long stop periods DRAIN PIPE During the summer time check that the unload of the condensation is not obstructed and that the pan is clean without dust or other things Eventual dirt may obstruct the unload causing the overflowing of the condensations water FAN MOTORGROUP As well the motor as the fans rotate on self lubricating bearings which do not need any lubrication Checkthe wheel is clean If this is not the case clean it using compressed air in such a way not to damage the wheel CONTROLLI ANNUALI Per un regolare funzionamento e buona conservazione dell unit si raccomanda di far effettuare da personale tecnico qualificato le periodiche
29. entendo l orientamento del flusso aria in 2 diverse direzioni revolved by 180 allowing the air flow to go into 2 different ways pannello PI o P2 si pu facilmente asportare per eventuali operazioni P and P2 panels can be easily removed in case of di manutenzione sull unit maintenance operations on the unit La griglia di aspirazione estraibile permette una facile pulizia del filtro The removable air intake grill allows an easy filter cleaning pannello viene fissato direttamente sull unit ad incasso quindi non necessita di The panel is fixed exactly on the concealed unit so than no frame alcun telaio o supporto murale per il montaggio NON necessario il falso telaio or wall support is required for the mounting it is not required any FTI sufficiente realizzare una nicchia con dimensioni precise false FTI frame just make a niche keeping the right dimension Compatibilit Compatibility VE MB 13 23 33 43 53 63 73 83 93P 103P 113P 123P Dimensioni Pannello Panel 2 L mm 700 900 1 100 1 300 1 500 1 700 Dimensions Nicchia Nike o or In mm 650 850 1 050 1 250 1 450 1 650 Pannello in lamiera prevemiciata SENZA sportellini quadro comando adatto per unit con comando remoto Panel made of pre painted steel WTHOUTcontrol panel doors suitable on units with remote control Idoneo per versioni Suitable for versions P1 VE VIF PMI VE Oll PMI Panne
30. holes for fixing to wall ceiling Thermal acoustic internal insulation class M1 Ventilatore centrifugo a doppia aspirazione pale curve avanti Double air inlet centrifugal fan forward curved fins 4 Motore elettrico 230V 1Ph 50Hz direttamente accoppiato al ventilatore Electric motor 230V 1Ph 50Hz directly coupled to the fan E Batteria di scambio termico 1 batteria per unit a 2 tubi 2 batterie per unit a 4 tubi Coil 1 coil for a 2 pipe system unit 2 coils for a 4 pipe system unit Collegamenti idraulici batteria Water coil connections 7 Valvola sfiato aria manuale Manual air vent valve Valvola svuotamento acqua manuale Manual water drain valve 9 Bacinella raccoglicondensa con scarichi isolamento termico per versioni verticali Drain pan with drain pipes thermal insulation for vertical versions 10 Scarico condensa Drain pipe 11 Filtro aria grado filtrazione classe M1 Air filter filtering efficiency Class M1 Accessori Accessories Quadro comando L unit standard viene fornita equipaggiata con il solo cavo motore SENZA QUADRO COMANDO E SENZA MORSETTIERA In questo Modo si pu 12 scegliere fra una vasta gamma di quadri comando e morsettiere accessori che vengono forniti gi montati sull unit sul lato opposto degli attacchi idraulici Control panel The standard unit is supplied only equipped with the motor cable WITHOUT CONTROL PANEL AND TERMINAL BOARD Thi
31. i ai valor assorbimento elettrico riportati sull etichetta matricolare dell unit OGNI PANNELLO COMANDI PUO CONTROLLARE UNA SOLA UNIT NOTA Per controllare pi unit oppure una unit con 2 si raccomanda di tenere le alimentazioni elettriche dei diversi motori SEPARATE ED INDIPENDENTI Per fare questo si raccomanda di installare 3 relays uno per ogni velocit con contatti indipendenti un contatto per ogni motore da controllare o installare la SCHEDA DI INTERFACCIA accessorio in questo modo qualsiasi anomalia dovesse intervenire in un motore non va ad interferire od influenzare gli altri Il luogo di montaggio del pannello comandi deve essere scelto in modo che il limite di temperatura ambiente massimo e minimo venga rispettato 0 45 C lt 85 U R II pannello comandi non pu essere montato su una parete metallica salvo che questa sia collegata alla presa di terra in modo permanente Accessori Temrmostato di minima temperatura acqua MM Il termostato di minima temperatura acqua consente di fermare automaticamente la ventilazione qualora la temperatura dell acqua in ingresso alla batteria scenda sotto i 40 C in regime di riscaldamento Inverno CAUTION make sure that electrical power to the unit is tumed off before making any electrical connection CAUTION wiring connections unit installation and have to be made only by specialised installers Please d
32. ing plant design installation operation and maintenance are the exclusive responsibility for the respective competencies of the designer installer and user WARNING It is important to verify that the design and installation conform with cument standards Dichiarazione Conformit Conformity Declaration DCF 0801 30025051 R00 Dichiariamo sotto la nostra esclusiva responsabilit che la macchina in oggetto Unit per il riscaldamento condizionamento ventilazione trattamento dell aria di ambienti civili residenziali commerciali ed industriali marchiata CE conforme alle direttive Europee Internazionali di sicurezza L unit conforme a Direttiva Macchine 98 37 CE ex 89 392 CEE e modifiche 91 368 CEE 93 44 CEE 93 68 CEE Direttiva Bassa Tensione 73 23 Direttiva Compatibilit Elettromagnetica 89 336 C EE Unit costruita e collaudata in conformit alle Direttive 92 31 CEE 92 59 CEE ed alle normative EN 292 1 EN 292 2 EN 294 EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 EN 60555 2 EN 60204 1 CEI EN 60335 1 CEI EN 60335 2 40 La Direzione Generale We declare under own responsability that the above equipment complies is Unit for heating conditioning ventilation and air treatment in civil residential commercial and industrial environments CE branded in accordance with European and Intemational security directives The unitis in ac
33. j 00 LOLOCGLLLLOININ 1249529 TVnNVIN Ee Y E EZ ETE NOILT1VISNI sepeesJedng eosinisogs 8JNy20 g 60 e7ey anbo e e95 0b0 ere9 2 31 1 FHOLVITVISNI 3LN3LN EU r4 Kcd d Mi IA enss oqeDs ny uonipz3 9uolssIu eues eueg seues 91195 CONDITIONING R VENTILCONVETTORI FAN COILS INDICE INDEX Osservazioni Remaster 2 Dichiarazione Conformit Conformity Declaration 0 0801 30025051 00 2 Simboli di sicurezza Safety symbols uiiuceu sionis EEE 3 Prescizioni di sicurezza Safety Measure S anaa anaa a aA UNES Componenti principali Main 4 imballo Paclkangi u cc 4 Trasporto Ricevimento Movimentazione Transport Receipt Handling 111 e eee creer erre rennen nana annm a aaa 4 Sipccaggio m canter Sipc king at Iie cio ye ike ras es isa a
34. legati all impianto di terra dell edificio According to the installation project install the chilled water lines the hot waterlinesand the electric power lines Alwaysmake sure that the unit and all its electrical partshave been corectly earthed priorto starting up the unit Assicurarsi che la valvola di alimentazione dell acqua sia chiusa Attendere che lo scambiatore si sia raffreddato Be sure that the inlet water valve is closed The exchange device has cooled down Sel unit deve essere smontata proteggere le mani con guanti da lavoro Fare attenzione agli spigoli di lamiera all interno dell unit Fare attenzione agli spigoli esterni dell unit Tenere libere le griglie di aspirazione f you have to disassemble the unit use special protective gloves Beware of sharp edgesinside the unit Beware of roof comersof outdoor units Keep suction gridsclear Perle unit con ventilatori accessibili versioni ad incasso non mettere in funzione l unit se la stessa non stata montata all interno di un vano accessibile solo con l uso di utensili Le ventole possono raggiungere la velocit di 1000 giri min Non inserire oggetti nell elettroventilatore n tantomeno le mani In the unit with accessible fans Concealed versions don t sart the unit if the unit itself is not Closed inside a space accessible only with the use of propertools Fanscanreach a speed of 1000 rpm Do not i
35. limentazione elettrica Power supply 230Vac Ph 50Hz resistenza elettrica 230V monofase Electrical heater 230V single phase AT Aria uscita ingresso Air supply intake AT 2 16 4 18 2 18 1 18 2 142 9 5 RB Potenza alta High power Mod RB 13 23 RB 33 43 RB 53 63 RB 73 83 RB 93 103 RB 113 123 Idoneo per tutte le versioni Suitable for all versions Accessori forniti montati o non montati a richiesta sull unit Accessories supplied mounted or not mounted on request on the unit Dati tecnici riferiti alle seguenti condizioni Press atmosferica 1013 mbar Portata aria di rif Portata aria Nominale Qa n dell unit standard 2 Tubi pi piccola Technical data referto the following conditions Atmospheric pressure 1013 mbar Air flow of ref Nominal air flow Qa n of the standard smaller 2 Pipe unit 1 Dati elettrici Valori rilevati con Wattmetro Jokogawa WT 110 1 Electrical data Measurements with Wattmeter Jokogawa WT 110 2 DTnominale resistenze DT riferito al 50 di Qa n Riferito alle pi probabili condizioni di funzionamento dell unit Qa con velocit lt max ed gt 0 2 Nominal el heaters DT DT refered to 50 of Qa n Refer to the most probable working conditions of the unit Qa with speed max and gt 0 MB Motore Brushless MB Brushless Motor Dati tecnici ventilconvettori con motore asincrono Zechnical data of fan coils with asynchronous motor
36. llo in lamiera prevemiciata CON sportellini quadro comando adatto perunit con quadro comando a bordo Panel made of pre painted steel WITH control panel doors suitable for units with on board control panel Idoneo per versioni Suitable for versions P2 VE VIF PMI VE Oll PMI Falso telaio in lamiera zincata adatto per pannelli P1 e P2 False frame made of galvanized steel suitable for P1 and P2 panels Il falso telaio NON necessario ma consigliato per garantire Veloce realizzazione di una nicchia con le corrette dimensioni necessarie Rapida installazione dell unit VE e dei pannelli P1 o P2 The false FTI frame is NOT required but suggested in order to Quickly make a niche of the right size Quickly install the VE unit and the PT or P2 panels Idoneo per versioni Suitable for versions FTI VE VIF PMI P1 P2 VE OII PMI P1 P2 MB Motore Brushless Brushless motor Dati Tecnici Batterie Co s Technical Data 2 TUBI 1 battena 2 PIPE 1 coil A al 4 TUBI 2 battere 4 PIPE 2 coils 1 Attacchi idraulici batteria Gas femmina Female gas water coil connections MODELLO MODEL LE cs ns Esse Batteria per Riscaldamento Condizionamento Heating Cooling coil Diametro int tubi Internal diameter tubes mm
37. ndersi a puro titolo informativo e riferiti alla data di stampa dello stesso L entrata in vigore di nuove disposizioni o di modifiche a quelle vigenti non costituir motivo di obbligo alcuno del costruttore nei confronti di terzi II costruttore responsabile della conformit del proprio prodotto alle leggi direttive e norme di costruzione vigenti al momento della commercializzazione La conoscenza e l osservanza delle disposizioni legislative e dele norme inerenti la progettazione degli impianti l installazione l esercizio e la manutenzione sono ad esclusivo carico per le rispettive competenze del progettista dell installatore e dell utente ATTENZIONE importante verificare che il progetto e l installazione siano conformi alle norme vigenti Norme EN Norme di sicurezza Regolamenti locali e siano approvati quando previsto dagli enti competenti al controllo in materia interpellare To use the unit conectiy and safely the installer the user and the maintenance man for their respective competencies must comply with whatis indicated in this manual Store this manual in a dry location to avoid deterioration asthey must be kept foratleast 10 yearsforany future reference All the information in this manual must be carefully read and understpod as they ll be all very useful for both safe installation and properuse amp maintenance operations Pay particular attention to the operating noms marked with DANGER or WARNING
38. ning Water entrainment Condensate on the extemal struc ture of the unit Siphon is clogged Clean siphon No siphon Fita siphon Temperature and humidity limit conditions indicated in the Technical Bullettin operating limits have been reached Race the watertemperature overthe minimum limits mentioned in the Technical Bulletin Condensate waterdraining problems checkthe drain pan and the drain pipe When the requested environment temperature is reached the fan stops while chilled water is still circulating in the coil provide a regulation where water supply is Stopped when environment temperature is reached fan stop 3 way valve 2 way valve pump OFF Chiller OFF etc Resistenze elettriche ectrical heaters Nota a richiesta i modelli di resistenza pi piccoli possono essere installati sulle unit di taglia maggiore stesso prezzo Es RA 13 23 700W pu essere installata su VE 33 In questi casi per la resistenza pi corta dell unit non copre tutta la superficie di passaggio dell aria e quindi una parte del flusso d aria non viene riscaldata Viene quindi garantita la potenza termica elettrica della resistenza W ma non la omogeneit della temperatura aria di mandata Note on request the smaller electric heaters sizes can be installed on larger size units same price Ex RA 13 23 700W can be installed on VE 33 However in the hereby cases the electric resistance shorter than the unit doe
39. no 10 anni per eventuali riferimenti futuri Leggere attentamente e completamente tutte le informazioni contenute in questo libretto forniscono importanti indicazioni riguardanti la sicurezza d installazione uso e manutenzione Prestare particolare attenzione alle norme d uso accompagnate dalle scritte PERICOLO o ATTENZIONE in quanto se non osservate possono causare danno all unit e o a persone e cose Per anomalie non contemplate da questo libretto tempestivamente il Servizio Assistenza di zona Assicurarsi che questo libretto accompagni sempre l unit Il libretto costituisce parte integrante ed essenziale del prodotto e dovr essere consegnato all utilizzatore Se l unit dovesse essere venduta o trasferita ad altro proprietario assicurarsi sempre che il libretto accompagni l unit in modo che possa essere consultato dal nuovo proprietario e o dall installatore Il costruttore declina ogni responsabilit per qualsiasi danno dovuto ad un uso improprio dell unit ad una lettura parziale o superficiale delle informazioni contenute in libretto dati tecnici le caratteristiche estetiche i componenti e gli accessori riportati nel presente libretto non sono impegnativi Il costruttore si riserva la facolt di apportare in qualsiasi momento tutte le modifiche ritenute necessarie per il miglioramento del proprio prodotto riferimenti a leggi normative o regole tecniche citate nel presente libretto sono da inte
40. nomeni di funzionamento Innalzare la temperatura acqua oltre i limiti minimi descritti nel Bollettino Tecnico condensazione sulla Problemi di drenaggio dell acqua di condensa verificare la bacinella e lo scarico condensa stnuttura este ma Raggiunta la temperatura ambiente desiderata il ventilatore si ferma mentre continua a circolare acqua fredda attraverso la dell unit batteria Predisporre il sistema di regolazione dell impianto in modo che a temperatura raggiunta oltre allo stop del ventilatore il flusso dell acqua attraverso la batteria si blocchi valvola 3 vie valvola 2 vie OFF della pompa OFF del refrigeratore ecc WARNING Before to access the Feeble air discharge Excessive air flow unit C UT OUT THE POVVER SUPPLY to the unit using the omnipolar switc h For anomalies don t hesitate contact the aftersales service immediately Wrong speed setting on the control panel Select the right speed on the control panel Obstructed air filter Clean the airfilter Obstruction of the airflow inlet and or outlet Remove the obstruction Air distribution system load loss hasbeen underestimated Increase fan speed Sense of rotation inverted Chech wiring diagram and electrical connections Air distribution system load loss hasbeen overestimated Reduce fan rotation speed and orcreate load lossin ducting Insuffic ient static pressure Rotation speed too low Increase fan speed Sense of rotation inverted Chech wiring diagr
41. nsert any object norhandsin the electric fan nstallare in prossimit dell unit in posizione facilmente accessibile un interruttore di sicurezza che tolga la corrente alla macchina Prima di qualsiasi operazione di pulizia o manutenzione togliere l alimentazione elettrica dall unit Prima di accedere all unit assicurarsi che tutte le utenze elettriche siano state interrotte In particolare prima di aprire i pannelli d ispezione accertarsi che il ventilatore sia spento e che non possa essere riacceso all insaputa di chi sta intervenendo sulla unit stessa VERIHCARE IL COLLEGAMENTO DELLA MESSA A TERRA We recommend to install a safety switch which can be easily reached to cut off the curent near the unit Before any cleaning and servicing operation cut off the power line to the unit Before opening the unit make sure that all electrical parts have been switched off In particular make sure that the fan is off and cannot be inadvertently started priorto opening inspection panels CHECK THE EARTHING Questa unit dovr essere destinata solo all uso di riscaldamento condizionamento Ogni altro uso da considerarsi improprio e quindi pericoloso Se l unit viene installata in ambienti con persone inabili e o bambini dovr essere posizionata in modo che non sia di facile accesso Assicurarsi che la porta di accesso ai comandi interni sia sempre chiusa Un errata installazione pu causare danni a persone anim
42. o delle Lamiera aluzink Lamiera acciaio inox Lamiera acciaio zincato For safety and quality reasons it is recommended to use original spare parts when replacing components To order spare parts you always have to indicate the unit model and the description of the part REPLACING PARTS Per la sostituzione dei componenti necessaria una specifica Since specific technical skills are required to replace the competenza tecnica per cui si raccomanda di rivolgersi sempre spare parts it is recommended to always contact skilled technical personnel ATTENZIONE Tutte le operazioni di sostituzione ricambi devono WARNING All the replace spare parts operations must be essere eseguite con l unit non funzionante escludendo camed out while the unit is tumed off disconnecting the water and electric supplies Smaltimento Waste disposal At the end of its operating life the UTA serie unit must be disposed according to the regulation in force in the installation country The units are manufactured with the following materia IS Aluzink plates Stainless steel plates Galvanized steel plates Copper Aluminium Stainless steel Polyester Polyethylene Glass fibre Plastic Ricerca guasti How fo detect failures ATTENZIONE Prima di accedere alla macchina TOGUERE TENSIONE mediante l intemutto re omnipolare posto a monte dell unit Peranomalie non contemplate interpellare tempestivamente il Servizio Assis
43. o not forget that warranty cannot be applied in case of electric mechanical and other general modific ations Compliance with the safety nomy laws applied in the country where the unit is installed Make sure that the technical data conceming the network meet the data indicated on the identification unit label Unit and accessories 230V electrical heater remote controls etc power supply Check that the line is single phase 230V 1Ph 50Hz and that the voltage remains within the limits Vmin 2195 Vmax 265 The work of the unit with voltages that are not within the above mentioned limits makesthe guarantee unvalid Make sure that the electrical plant is able to supply in addition to the working cument required by the unit also the current required to supply the domestic units already in use C HEC K THE EARTHING The electrical safety of the unit is attained only when the unit itself is comectly connected and efficiently earthed according to the existing safety standards When connecting ensure that the earth wire is longerthan the live wires so that it will be the last wire to break if the supply cable is stretched thus ensuring a good earth continuity CONNECTION CABLES SPEC IAC ATIONS Carry out all unit connections usng cables of adeguate dimensions for the power used in accordance with the local laws in force Their dimensions must be of such dimensionsto cause a phase voltage drop of less 396of the nominal voltage Use HO5V
44. of dirt and foreign bodies Norme per l utente Assistenza nformation for the user After sales service ATTENZIONE Per tutte le operazioni di installazione messa in funzione manutenzione ecc avvalersi sempre dell opera di personale professionalmente qualific ato Prima di telefonare al Servizio Tecnico accertarsi di avere a portata di mano la documentazione della macchina e possibilmente Modello unit e Numero di matricola Descrizione anche sommaria del tipo di installazione WARNING For all installation operations start up etc always consult a qualified service engineer Before calling for service make sure the unit technical data and manual iswithin reach and namely Unit model and Product serial no Brief description of the installation type Norme per l utente Ricambi nformation for the user Spare parts Ai fini della sicurezza e della qualit si raccomanda di utilizzare per le sostituzioni componenti e ricambi originali Per l ordinazione delle parti di ricambio citare sempre il modello dell unit e la descrizione del componente SO STITUZIO NE COMPONENT ad un Centro Assistenza Tecnica autorizzato l alimentazione acqua ed elettrica normative vigenti nel paese di installazione materiali che compongono le unit sono Rame Alluminio Acciaio inox Poliestere Polietilene Fibra di vetro Plastica A fine vita le unit devono essere smaltite nel rispett
45. ollare la caldaia n Controllare che L alimentazione elettrica sia inserita Gli interruttori e o i termostati siano nella esatta posizione di funzionamento Controllare che Non vi siano corpi estranei a bloccare la rotazione della ventola Mancanza di acqua calda Controllare la caldaia e la pompa acqua calda Pont non riscalda Impostazione piro del pannello comandi Impostare correttamente il pannello comandi come in precedenza Controllare che Il filtro aria e la batteria siano puliti Controllare che Non sia entrata aria nel circuito idraulico sfiatando dall apposita valvola sfiato aria Controllare che L impianto sia bilanciato correttamente La caldaia funzioni La pompa acqua calda funzioni Mancanza di acqua fredda Controllare il refrigeratore e la pompa acqua 3 Puni non raffredcda Impostazione errata del pannello comandi Impostare correttamente il pannello comandi come in precedenza Controllare che filtro aria e la batteria siano puliti Controllare che Non sia entrata aria nel circuito idraulico sfiatando dall apposita valvola sfiato aria Controllare che L impianto sia bilanciato correttamente Il refrigeratore funzioni La pompa acqua fredda funzioni 8 Trascinamento d acqua Sifone intasato Pulire il sifone Sifone mancante Inserire un sifone Sono state raggiunte le condizioni limite di temperatura e umidit descritte nel Bollettino Tecnico Limiti di Fe
46. one 15 mm Appropriatly insulate water pipes to prevent dripping in cooling mode Install an appropriate size condensate drainage system and place it to favour the discharge min 396 and must not have rising parts or stra nglings in orderto allow a regular downflow Install a siphon in condensate drainage system The drain pipe will be connected to an unloading rain network Do not use white or black water sewage system to prevent unpleasant odour retum into the room in case of evaporation of the water contained in the siphon A fine lavori verificare il regolare deflusso della condensa versando dell acqua sulla bacinella Installazione Collegamento elettrico nsfa ation Electrical connections UNIT COSTRUITA IN CONFORMIT ALLA DIRETTIVA CEE 73 23 UNITMANUFAC TURED ACCORDING WITH CEE 73 23 STANDARD AAA ATTENZIONE prima di effettuare qualsiasi intervento assic urarsi che l alimentazione elettrica sia disinserita ATTENZIONE i collegamenti elettrici l installazione dell unit e dei suoi accessori devono essere eseguiti solo da personale specializzato Tenere presente che modifiche elettriche meccaniche e manomissioni in genere fanno decadere la garanzia Osservare le norme di sicurezza vigenti nel paese di installazione Verificare che le caratteristiche della rete elettrica siano conformi ai dati di targa dell unit Alimentazione elettrica unit ed accessori resistenza elettric
47. ontrosoffitti ecc in caso di manutenzione straordinaria e o sostituzione dell unit S The unit hasto be installed in orderto allow ordinary maintenance and special Wr L unit deve essere installata o posizione tale da consentire lt maintenance Installazione Collegamento idraulico nsfa lation Water supply connections Attenzione Usa re sempre chiave e c ontroc perlallacciamento della battena alle a N N ttuba zio ni Effettuare i collegamenti idraulici Prevedere valvole di intercettazione MIN 1 2 per isolare la batteria dal resto del circuito in caso di manutenzione straordinaria Collegare l entrata con una valvola a sfera e l uscita con una valvola di bilanciamento o detentore o installare 2 valvole a sfera Prevedere una valvola di sfiato in alto ed una di scarico in basso le batterie di scambio termico per acqua sono collaudate alla pressione di 30 Bar e pertanto sono idonee a funzionare in esercizio sino alla pressione massima di 15 Bar Staffare adeguatamente i tubi all esterno dell unit per evitare di scaricarne il peso sulla batteria Prevedere dispositivi antigelo Nel caso di installazione in zone con climi particolarmente freddi svuotare l impianto dall acqua in previsione di lunghi periodi di fermata dell impianto Make hydraulic connections Install shut off valves M
48. r working Iim ESP Pa 57Pa Sa 57Pa 57 Pa 69Pa 80Pa soPa 99Pa 99Pa 98Pa s8Pa 2 112Pa Qa x m3 h sola 30s X634 soin xoi xow lado Laok 5016 00000 2 RIDUZIONE POTENZIALIT FRIGORIFERA TERMICA in funzione della riduzione portata aria 2 COOLING HEATING CAPACITY REDUCTION depending on air flow reduction _095 0 90 0 85 0 80 0 75 0 70 0 65 0 60 055 0 50 045 040 035 0 30 025 020 0 15 Potenzia Frigorifera Totale Total 1 00 Cooling capacity Sensibile Sensible 1 00 Potenzialit termica Heating capacity 1 00 Dati tecnici riferiti alle seguenti condizioni Unit Standard Pressione atmosferica 1013 Technical data referto the following conditions Standard unit Atmospheric pressure mbar Alimentazione elettrica 230Vac 1Ph 50Hz 1013 mbar Power supply 230Vac 1Ph 50Hz 1 Portata aria e Press statica Valori nominali rilevati con cassone rif norme AMCA210 1 Air flow and Static pressure Nominal data measured with casing ref AMCA210 74 fig 12 74 fig 12 e condotto diaframma rif norme CNR UNI10023 standards and plenum diaphragm ref CNR UNI10023 standards 2 Rese Frigorifere e Termiche Valori calcolati da SW e dati rilevati in camera 2 Cooling and Heating capacities Dota calculated by SW and measurements made in calorimetrica rif norme UNI 7940 parte 1 2 UNI EN 1397 2001 calorimetric room ref UNI 7940 part 1 2
49. rogramma di ispezioni e manutenzione programma di manutenzione seguente stabilito considerando condizioni ottimali sullo stato di inquinamento dell aria del luogo di installazione Quindi le indicazioni dei tempi di intervento per una corretta manutenzione sono puramente indicativi e possono variare in relazione alle effettive condizioni di lavoro Le condizioni atmosferiche pi aggressive si hanno quando nell aria esiste una quantit anomala di fumi industriali sali fumi chimici e polveri industriali These units are constructed with state of the art technology that ensures long terms efficiency and operation tisessentialto provide very specific inspection and maintenance program in functions of those fluids characteristics The following maintenance program is established by taking into consideration the unit optimal conditions relative to the air quality and the installation site characteristic s The response time fora correct servicing very much depends on the above conditions The most aggressive atmospheric conditions happen when in the air there is an abnormal quantity of industrial fumes salts chemical fumes and airbome dust PER PULIRE L UNITA ATIENZIO NE Togliere tensione prima di iniziare le operazioni di pulizia dell unita Non indirizzare getti d acqua sull unit Pu causare scosse elettriche o danneggiare l unit Non usare acqua calda sostanze abrasive o solventi per pulire l unit usare un panno
50. s Idoneo per versioni Suitable for versions PCPB VE VMI P VE OMP 4P Pannello di chiusura posteriore basso in lamiera prevemiciata Lower closing back panel made of pre painted steel Idoneo per versioni Suitable for versions PCPF VEVMI VE VMF VE OMP VE OMI Pannello di chiusura inferiore senza griglia in lamiera prevemic iata Bottom closing panel without grill made of pre painted steel PCB Idoneo per versioni Suitable for versions VE VMF VE OMI MB Motore Brushless Brushless motor Pannelli per montaggio unit incasso su nicchia Pane s for units to be installed in a niche SPP PFF FPI F VEIVIF Dimensioni nicchia per installazione senza Nike dimensions for installation without FT Ln x Hn 620 x Sn 220 VEIVIF D VEIVIF VEIVIF Pannelli in lamiera prevemiciata idonei per l installazione su versione incasso verticale VNF o su versione incasso orizzontale ONF horizontal ONF concealed versions NOTA Per il montaggio dei pannelli P1 o P2 necessario NOTE The PMI accessory air supply 90 plenum is l accessorio PMI plenum 90 di mandata aria required when mounting P1 or P2 panels le griglie di aspirazione e mandata aria sono estraibili e possono ruotare di Both air intake and air supply grills are removable and can be 180 cons
51. s Attacchi circolari Spigots No x 200 180 160 mm 1x6 2x0 2x0 3x 4Ax 4 Mandata aria Coibentato Air supply Insulated Attacchi circolari Spigots No x 200 180 160 mm 4x4 PA Apirazione aria con filtro aria Air intake with air filter MB Motore Brushless Accessori forniti montati o non montati a richiesta sull unit A richiesta Plenum e Raccordi realizzati su specifica del cliente MB Brushless Motor Accessories supplied mounted or not mounted on request on the unit On request Plenum and Connections can be realised on specific customer need drawing approval will be required Chiusure posterioried inferiori per versionicon mobile Back and bottom closing panel for versions with cabine richiesta approvazione del disegno PCPF PCPB VE VMF Accessori idonei per l installazione sulle versioni con mobile verticali ed orizzontali Accessories suitable for installation on versions with cabinet vertical and horizontal Compatibilit Compatibility VE MB 13 23 33 43 53 63 73 83 93P 103P 113P 123P L1 mm 640 840 1 040 1 240 1 440 1 640 Dimensioni Dimensions 12 mm 670 870 1 070 1 270 1 470 1 670 L3 mm 430 630 830 1 030 1 230 1 430 Pannello di chiusura posteriore medio in lamiera prevemiciata idoneo per unit con mobile accessorio zoccoli P Central closing back panel made of pre painted steel suitable for unit with cabinet accessory P feet
52. s not cover the full width of the unit and the air flow is only partially heated It is then guaranteed the thermal electrical power of the resistance W but not the homogeneity of the air supply temperature Compatibilit Compatibility VE MB 13 23 33 43 53 63 73 83 93 103 P 113 123 P Resistenza elettrica 230V Relay di potenza Temostato di sicurezza TS Monostadio Electrical heater 230V Power relay Safety thermostat TS Single stage Potenzialit Termica Heating capacity W 700 W 1 000 W 1 500 W 2 000 W 2 000 W 2 000 W Assorb Elettr Res elettrica Electrical heater current input 1 3 05 A 4 35 A 6 53 A 8 70 A 8 70 A 8 70 A Alimentazione elettrica Power supply 230Vac Ph 50Hz resistenza elettrica 230V monofase Hectrical heater 230V single phase AT Aria uscita ingresso Air supply intake AT 2 11 5 12 1 13 6 12 1 9 5 6 3 RA Potenza bassa Low power Mod RA 13 23 RA 33 43 RA 53 63 RA 73 83 RA 93 103 RA 113 123 Idoneo per tutte le versioni Suitable for all versions Resistenza elettrica 230V Relay di potenza Termostato di sicurezza 5 Monostadio Electrical heater 230V Power relay Safety thermostat TS Single stage Potenzialit Termica Heating capacity W 1 000 W 1 500 W 2 000 W 3 000 W 3 000 W 3 000 W Assorb Elettr Res elettrica Electrical heater current input 1 4 35 A 6 53 A 8 70 A 13 05 A 13 05 A 13 05 A A
53. s running and to control the temperature through the regulation of 2 way or 3 way valves or we recommend to 0 3 vie oppure scegliere comandi con funzione antidestratific azione choose a control panel provided with anti desertific ation function Norme per l utente Usi impropri nformation for the user Improper use NON STRATTONARE IL CAVO ELETTRICO E molto pericoloso tirare calpestare schiacciare o fissare con chiodi o puntine il cavo elettrico di alimentazione Il cavo danneggiato pu provocare corto circuiti e danni alle persone NON INHLARE OGGETTI SULL USC ITA DELL ARIA Non inserire oggetti di nessun tipo nelle feritoie di uscita dell aria Ci potrebbe provocare ferimenti alla persona e danni all unit NEVER INSERT ECTS IN THE AIR OUTLET Never insert objects in the airoutlet slats This could cause physical injury or damage the unit ORIENTARE CORRETIAMENTE NEVER J ERK OR TWST THE POWER CABLE Never pull walk over crush or secure the electric power cable with nails or tacks A damaged cable could cause short circuits or physical injury NON USARE L UNIT IN MODO IMPROPRIO L unit non va utilizzata per allevare far nascere e crescere animali Su richiesta versioni speciali es acciaio INOX IMPROPER USE OF THE UNIT CONSTITUTES A HAZARD The unit is not designed forany type of animal breeding or similar applications On request special versions ex stainless steel
54. s way you can choose among a large range of control panels and terminal boards options which are supplied mounted on the unit opposite to water connection side Sonda termostato di minima temperatura acqua Water low temperature thermostat sensor Sonda termostato ambiente a bulbo Bulb room temperature sensor Uh Bacinella ausiliaria raccoglicondensa per versioni verticali Auxiliary drain pan for vertical versions Y Imballo Packing Le unit vengono spedite con All interno dell unit si trova una busta contenente imballo standard costituito da uno ati il manuale di installazione uso e manutenzione ed scatolone in cartone e pallets gli a il certificato di garanzia Su ogni singola unit accessori vengono forniti sfusi am applicata l etichetta di identificazione riportante imballati a parte o gi montati ic e Dati del costruttore e Modello dell unit e Codice di identificazione Dati tecnici e Schemi elettrici There isan envelope inside the unit containing the installation use and maintenance manual and the warranty documents The identification label bearing the following data is applied on each unit e Manufacturers data sull unit su richiesta Units are shipped with carton boxes on pallet as standard packing accessories are supplied loose in packed separately or supplied mounted in the unit on
55. sciare gli elementi dell imballaggio a portata dei bambini in quanto Always keep packing parts away from children reach as they may be fonti di pericolo harmful Indossare adeguati indumenti protezione prima procedere Before the unit installation please wear suitable protective clothes Use all installazione dell unit Utilizzare idonea attrezzatura per prevenire suitable equipments and toolsto avoid any installation accident incidenti nel corso dell installazione Before the unit installation we recommand to muont on the unit the eventual Prima di procedere all installazione si raccomanda di montare sull unit gli separating optionals by following the assembly instructions contained in each eventuali accessori separati seguendo le istruzioni di montaggio contenute in single kit ogni singolo Kit Decide the installation position Locate the unit on a solid structure which Decidere la posizione di installazione Posizionare l unit su di una struttura solida does cause vibrations and isable to support the machine weight che non causi vibrazioni e che sia in grado di sopportare il peso della macchina Throught the 4 fixing openings foreseen on the bearing structure sign the Segnare attraverso le 4 aperture di fissaggio predisposte sulla struttura position of the holding expansion dowels Do the holes for the dowels Install portante la posizione dei tasselli di sostegno ad espansione Eseguire la the unit with no 4 e
56. sibile Sensible Cooling capacity 1 30 120 110 095 090 0 85 LxHxS mm L6 0xH520x5220 L870 xH 520 x S 220 L 1 070 x H 520x S 220 L 1 270 x H 520 x S 220 L 1 470 x H 520x S 220 A B mm 400 B 425 600 B 625 800 B 825 A 1 000 B 1 025 A 1 200 B 1 225 1 1 1 1 1 2 1 2 1 2 0 50A 70W 0 50A 75W 0 60A 75W 0 60A 75W 0 60A 1 14 1 52 1 42 1 18 1 13 1 00 1 00 1 00 1 00 1 00 1 00 1 00 0 80 0 80 0 52 0 63 0 59 0 51 0 49 0 43 0 43 1 01 1 31 1 22 1 01 0 96 0 88 0 88 0 89 0 86 0 86 0 85 0 85 0 70 0 70 0 46 0 54 0 51 0 44 0 42 0 37 0 37 0 90 1 08 1 00 0 83 0 79 0 73 0 73 0 79 0 71 0 71 0 70 0 70 0 58 0 58 0 41 0 45 0 42 0 36 0 34 0 31 0 31 0 78 0 73 0 68 0 60 0 57 0 45 0 45 0 69 0 48 0 48 0 51 0 51 0 36 0 36 0 36 0 30 0 28 0 26 0 25 0 19 0 19 0 61 0 33 0 31 0 30 0 29 0 23 0 23 0 53 0 25 0 25 0 28 106Pa 10 20 81Pa 0 20 81Pa 0 20 85Pa x0 20 85 0 20 83Pa x0 20 83 0 20 103Pa 10 20 74Pa x0 19 75Pa x0 19 82Pa x0 20 83Pa 0 20 79Pa x0 20 79 00 20 90Pa x0 18 64Pa x0 18 64Pa x0 18 68Pa x0 18 68Pa 10 18 63Pa x0 17 63Pa x0 17 1 20 1 60 1 50 1 23 1 18 1 00 1 00 1 00 1 00 1 00 1 00 1 00 0 80 0 80 0 55 0 66 0 62 0 54 0 51 0 43 0 43 1 07 1 37 1 29 1 05 1 01 0 88 0 88 0 89 0 86 0 86 0 85 0 85 0 70 0 70 0 49 0 57 0 54 0 46 0 44 0 37 0 37 0 95 1 13 1 06 0 86 0 83 0 73 0 73 0 79 0 71 0 71 0 70 0 70 0 58 0 58 0 43 0 47 0 44 0 37 0
57. soffice Evitare possibilmente il funzionamento durante la pulizia dei locali TO CLEAN THE UNIT WARNING Switc h off power supply before cleaning unit Do not splash water on the unit It could result in electrical shock or damage to the unit Do not use hot water abrasive powdersor strong solvents to clean unit use a soft cloth If possible avoid the working during the cleaning of the rooms AAA S MANUTENZIO NE ORDINARIA RISERVATA ALL UTENTE NOTA Una manutenzione accurata sempre fonte di risparmio e di sicurezza Si raccomanda di eseguire all inizio di ogni stagione di condizionamento all inizio di ogni stagione di riscaldamento e successivamente almeno ogni mese di funzionamento le seguenti operazioni Pulire semplicemente con un panno umido le parti esterne dell unit ALIO ARIA Pulizia ogni 15 giomi La pulizia pu essere effettuata mediante sbattimento del materassino lavandolo con un getto d acqua e detersivo oppure con un getto d aria compressa IMPORTANTE per pulire il filtro i getti di aria acqua devono essere rivolti in senso contrario a quello normale di aspirazione dell aria e non devono essere troppo violenti da danneggiare la massa filtrante Se i filtri vengono puliti con acqua prima del loro utilizzo lasciarli asciugare con cura per non compromettere l efficienza del sistema BATTERIA PER ACQUA La batteria di scambio termico deve essere mantenuta in perfetto stato per garantire l
58. sono all interno della morsettiera dell unit cavi all uscita dal tubo o canalina devono essere posizionati in modo da non subire sollecitazioni a trazione o torsione e comunque protetti da agenti esterni Cavi a trefolo possono essere usati solo con capicorda Assicurarsi che i trefoli dei fili iano ben inseriti COLLEGAMENTO ELETTRIC Effettuare l allacciamento elettrico secondo lo schema elettrico TUTTI GLU SCHEMI ELETTRICI SONO SOGGETTI AD AGGIORNAMENTO OPPORTUNO FARE RIFERIMENTO ALLO SC ELETTRICO ALLEGATO ALLUNITA Per l alimentazione generale dell unit non consentito l uso di adattatori prese multiple e o prolunghe dovere dell installatore prevedere il montaggio il pi vicino possibile all unit del sezionatore dell alimentazione elettrica Per proteggere l unit contro i cortocircuiti l unit dovr essere collegata alla linea di alimentazione elettrica mediante un appropriato interruttore omnipolare magnetotermico con apertura minima dei contatti di 3 mm per la scelta dell interruttore pi adatto vedi tabella assorbimenti elettrici Si definisce interruttore omnipolare quello con possibilit di apertura sia sulla fase che sul neutro Questo significa che alla sua apertura entrambi i contatti risultano aperti L interruttore omnipolare o la eventuale spina collegamento per mezzo di cavo e spina devono essere posizionati in luoghi accessibili ASSORBIMENTO _ELEMRICO Fare nfernimento d
59. tenza GUASTO PO SSIBILI CAUSE VERIAC HE RIMEDI Errata impostazione della velocit sul pannello comandi Scegliere la velocit corretta sul pannello comandi Filtro aria intasato Pulire il filtro aria 1 Poca ana in uscita Ostruzione del flusso d aria entrata e o uscita Rimuovere l ostruzione Perdita di carico del sistema di distribuzione sottostimate Aumentare la velocit di rotazione del ventilatore Senso di rotazione invertito Verificare lo schema elettrico ed i collegamenti elettrici 2 Portata aria eccessiva Perdita di carico del sistema di distribuzione sovrastimate Ridurre la velocit di rotazione del ventilatore e o inserire una perdita di carico nel canale 3 Pressione statica Velocit di rotazione troppo bassa Aumentare la velocit di rotazione del ventilatore insuffic iente Senso di rotazione invertito Verificare lo schema elettrico ed i collegamenti elettrici Portata aria eccessiva Ridurre la portata aria 4 Rumorosit eccessiva Rottura dei lamierati Verificare l integrit dei componenti e sostituire le parti danneggiate Mancata equilibratura delle parti rotanti Riequilibrare la girante del ventilatore Mancanza di corrente Controllare la presenza di tensione elettrica il motore ventilatore intervenuto se presente il termostato di minima temperatura acqua TM perch l acqua scesa sotto i 40 C nel 5 non gira funzionamento invernale Contr
60. uipment n case of breakdown or failure tum unit off do not Neverleave tools spare parts etc inside the unit try to repairit on yourown call operator Make sure that all inspection panels are closed properly fyou are going to leave the generator off fora long Do expose the unit to inflammable gases time first make sure that in no way this could cause harm to anyone in any way Tenere presente che modifiche elettriche meccaniche e manomissioni in genere fanno decadere la garanzia Please do notforgetthat warranty cannot be applied in case of electric mechanical and other general modifications Componenti principali Main components Di serie Standard Mobile di copertura in lamiera zincata e prerivestita da film di cloruro di polivinile colore bianco simile a RAL 9010 griglia mandata aria a doppio ordine di alette orientabili singolarmente colore bianco simile a RAL 9002 mobili disponibili in diverse versioni Cabinet made of galvanized steel pre covered with a film of polyvinyl chloride white colour similar to RAL 9010 Double bank singulariy adjustable louvers made of ABS white colour similar to RAL 9002 cabinets available in different versions 2 Struttura portante in lamiera zincata di forte spessore con fori per il fissaggio a muro soffitto Isolamento interno termoacustico classe M1 Bearing structure made of large thickness galvanized sheet steel with
61. xpansion screws 8 MA orthreaded rod 8 mm Install the foratura per i tasselli Installare l unit con n 4 viti ad espansione 8 MA o unit in mode that the intake and supply airisnot compromised barra filettata p 8 mm Installare l unit in una posizione tale da non Versions for concealed installation compromettere l aspirazione e l emissione dell aria The installer hasto take the necessary stepsto disguise it with appropriate panels Versioni per montaggio ad incasso false ceilings false walls panels ect which also serve as FIXED PROTECTION L installatore DEVE provvedere a mascherare appropriati pannelli The protection panels have to be firmly fixed only by tools to prevent contact controsoffitti contropareti pannelli di chiusura ecc che devono avere with dangerous parts 98 37 C EE like sharp edges electric parts runnging fans anche la funzione di PROTEZIONE FISSA I pannelli di protezione DEVONO essere ect but easily removable to allow total access to the unit extraordinary fissati solidamente con sistemi che richiedono l uso di utensili per la loro maintenance apertura es viti per impedire all utente di accedere alle parti pericolose 98 37 CEE quali spigoli vivi angoli acuti parti elettriche ventilatore in movimento ecc pannelli devono poter essere rimossi con utensile per consentire il TOTALE ACCESSO all unit evitando il rischio di dover rompere danneggiare strutture e mascheramenti cartongessi c
62. zzo secondo le istruzioni del costruttore da personale professionalmente qualificato o dai Centri di Assistenza autorizzati dal costruttore Solo personale precedentemente addestrato e qualificato pu eseguire le operazioni di installazione e manutenzione dell unit Per personale professionalmente qualificato si intende quello avente specifica competenza tecnica nel settore dei componenti di impianti di riscaldamento e condizionamento In ogni caso telefonando al Costruttore potrete ricevere le informazioni necessarie nsallation isto be carried out always strictly complying with the curent standards of the country where the appliance is going to be used and following of course the instructions given by the maker Only skilled operators and Authorized Assistance Centers will be entitled to out installation installation and maintenance operations of the unit can be carried out by qualified and trained personnel only Qualified service engineers are those having specific technical experience in the field of heating and cooling installation unit for home use according to CORGI Register In any case telephone in Manufacturer office and you can receive all informations Sulla base del progetto di installazione predisporre le linee di alimentazione dell acqua refrigerata dell acqua calda e della energia elettrica Non mettere in funzione l unit senza che essa ed i suoi componenti elettrici siano stati col