Contents
1. street lamp W LIGHT 24V BATTERY SYSTEM Fig 2 Wiring scheme This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl lt WESTERN CO SPB LS Manuale Utente D E Rev 1 2 ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS User Man ual 14 01 2013 Displaying and Protections PV LED Functionality The number of flashes indicates the intensity of current from the PV Green module 1 1 flash with a pause of 4 3 sec 0 5A lt PV current lt 1 5A 2 flashes with a pause of 4 3 sec 1 5A lt PV current lt 2 5A oe V TYY YyvtwY zt so on EEE SES OG values 13 flashes with a pause of 4 3 sec 12 5A lt PV current lt 13 5A 1 13 TUOI IONI asso A T LED Functionality It indicates the system status If always ON it indicates a system anomaly a reset is needed w 1 flash every 2 2 seconds the Low Battery protection is ON the load is deactivated you have to wait that the PV module recharges the battery and after that the protection deactivates condition of normal working 2 flashes every 2 2 seconds the Overload protection is ON the load is deactivated after about 2 minutes the load is restored it makes 3 attempts in sequence then it will wait the following night to try again 3 flashes every 2 2 seconds Over temperature p
2. All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl
3. SPB LS Manuale Utente WESTERN CO SPB LS User Manual ELECTRONIC EQUIPMENTS SOLAR SYSTEMS Rev 1 2 14 01 2013 VI n VIN m REGOLATORE DI CARICA PER IMPIANTI DI ILLUMINAZIONE FOTOVOLTAICI ii SPB LS un regolatore per la carica di batterie da modulo fotovoltaico appositamente progettato per l impiego in impianti di illuminazione off grid lampione fotovoltaico Il regolatore SPB LS alloggiato all interno di un contenitore metallico protetto all acqua grado IP66 quindi pu essere installato direttamente sul palo fotovoltaico senza dover aggiungere ulteriori protezioni Il circuito di carica dal modulo PV implementa un efficiente algoritmo di ricerca del punto di massima potenza MPPT in grado di funzionare su un esteso campo di tensioni ammessa una tensione massima sul modulo fino a 100V Il regolatore pu caricare indifferentemente batterie al piombo sia a 12V che a 24V all accensione l SPB LS riconosce automaticamente se la batteria a 12V o 24V e automaticamente regola le soglie di ricarica Il regolatore gestisce automaticamente l accensione e lo spegnimento della lampada al crepuscolo si rivela i crepuscolo quando la tensione del modulo PV scende sotto la soglia Vnight il regolatore accende la lampada e la mantiene accesa per un numero di ore configurabili dall utente l impostazione di default di 8 ore Si possono anche impostare dei programmi di accensione lam
4. dVch dVib 0 96 r dVch dVIb V Vcharge V 12V x2 24V 25 0 30 0 35 0 K X yl Temp C Ibatt Iload A SPECIFICHE TECNICHE i inse e panten ione e paten Min ive mox min Typ m Tensione di batteria batt 10v 12v 17v 20v 24v 3v Tensione di pannello a circuito aperto Vpan 20v 100v dov 100v Corrente di pannello pan A 185 Massima potenza di pannello Pmax zw OW Pensione usta cario oad __ won _ __ Mat Tensione di ricarica a 25 C alal SW_6 gt FLOOD 14 88V 29 76V Compensazione della Vch in funzione della e pe pe beni C temperatura di batteria Tbatt vedi Grafico 1 Tensione di Low battery SW_5 gt ON E Ue a SW_7 gt OFF 11 52V 23 04V ey I e I a Grafico 2 Tensione uscita Low battery a 25 C Vout_lb Lei Vch 0 24v Vch 0 48V Compensaione della Vib con SW_5 gt OFF vedi Vremlb 58mV A 58mV A Sela a Tensione rilevazione giorno impostabile Vday 688v 1136v Tensione rilevazione notte Vnight Vday 0 8V___ Vnightt 448 896v Auto consumo Maso a im A Temperatura ambiente di esercizio ss Tamb 10C 50 orc 50c Grado di protezione a Peso Dimensioni scatola mm 160x135 H65 Ingombro con cavi mm 160x170 H65 This document is the property of WESTERN CO Srl All rights are r
5. 2 Eseguire i cablaggi della lampada del modulo PV e della batteria come nello schema a pag 2 Insieme al regolatore SPB LS sono forniti in dotazione tutti i cavi necessari a fare i collegamenti interni del lampione PV 3 Deve essere impostata la configurazione per le batterie Spostare lo switch n 5 alla posizione ON se le batterie sono situate vicino al regolatore come nel testapalo completo mentre posizionarlo a OFF se le batterie sono lontane dal regolatore Spostare lo switch n 6 selezionando il tipo di batteria in uso per adeguare la corretta tensione di ricarica Ven Si deve impostare la configurazione SEAL se si usano batteria ermetiche VRLM o di tipo GEL mentre si deve scegliere la configurazione FLOOD se si usano batterie ad acido libero Spostare lo switch n 7 selezionando la profondit di scarica del banco batteria tra 30 e 70 Ci determina l autonomia del sistema in assenza di sole con 70 avremo un autonomia maggiore ma la vita attesa del banco batteria si riduce Consigliamo generalmente una DoD del 30 Impostare tramite gli switch n 1 2 3 4 il programma di gestione del carico adeguato alla propria applicazione Collaudo impianto Appena messo in funzione il sistema procedere al collaudo e Con il modulo PV esposto al sole verificare che SPB LS ricarichi la batteria osservando il led PV che indica l intensit di corrente dal modulo PV Effettuer dei lampeggi come da tabella e Verificare che il led 12V 24V no
6. hours with reduced flux dimmer In this way you can check accurately the lamp consumption so to remain inside the dimensioning of the PV off grid system FEATURES e 12V 24V battery voltage system e 225W 450W max PV power for 12V 24V systems e MPPT charge with module voltage up to 100V e Integrated blocking diode e Sealed or Flooded Lead Acid Battery e Temperature compensation of charge voltage e Low Battery Protection e Over temperature Protection e Overload Protection e Protection for battery polarity inversion e Lamp power on at full flux and reduced flux e IP66 for Outdoor Applications GEL AGM FLOOD DISCHARGE PROTECTION NIGHTLIGHT FUNCTION This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl WESTERN CO SPB LS Manuale Utente ii Rev 1 2 NE LECINORIC ODIA SOC NCS YSTEEES SPB LS User Manual 14 01 2013 Wiring PV Module ener NS z TXP TURI E lt amp mt ja Mort OTe cic I WUD wo Mi lt i ng ci ef ecza Co se ek he eee l lt z Da Ri ORE a at 00 010 i O DIMMERLED f ti Hite Sca W u agao 7 mt Configuration switch SAC LU Ww Lu Wy Lu oc E T oe Lu A gt 3 Lu H 12V BATTERY SYSTEM BATTERY
7. riportato uno schema di principio 1 Circuito di ricarica adatta la Vpan e la Ipan rispettivamente tensione e corrente del modulo fotovoltaico in modo da ricercare la condizione in cui la potenza erogata dal modulo PV massima realizzando quello che nella letteratura tecnica indicato con la sigla MPPT Maximum Power Point Tracking Inoltre gestisce la ricarica della batteria riducendo la corrente erogata verso la IPAN batteria nelle condizioni in cui la tensione Vegar supera la sua tensione di ricarica Ve 2 Diodo di blocco serve ad evitare che durante la notte quando il modulo fotovoltaico non illuminato questo possa assorbire corrente dalla batteria 3 Circuito per il controllo del carico accende o spegne il carico secondo il programma impostato dall utente comanda la segnalazione Dimmer e provvede al distacco del carico in caso di batteria scarica o sovraccarico 4 Microcontrollore controlla l intero circuito misura le correnti e tensioni del modulo della batteria e del carico esegue l algoritmo MPPT SPB LS IBATT gt morso l 1 i L O Licia 3 ea ILOAD Bevvvvv990v009 Fig 2 schema di principio This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl lt WESTERN CO SPB LS Manuale Utente Ei a Rev 1 2 Ny EL
8. wide range of PV modules thus ensuring the optimum exploitation of the whole power The PV module has to be chosen according to the battery nominal voltage and respecting the constraints of SPB LS panel input max open circuit voltage 100V and max PV panel power 225W with 12V battery and 450W with 24V battery Battery nominal voltage PV modules features Vmp voltage at maximum power at T 25 C gt 15 0V Voc open circuit voltage at T 10 C lt 100V 12V battery nominal Pmax Maximum power at 25 C lt 225W voltage We recommend silicon modules either mono or poly crystalline with a minimum number of 36 cells to a maximum of 144 cells Vmp voltage at maximum power at T 25 C gt Voc open circuit voltage at T 10 C lt 100V 24V battery nominal Pmax Maximum power at 25 C lt 450W volta ge We recommend silicon modules either mono or poly crystalline with a minimum number of 72 cells to a maximum of 144 cells Installation of SPB LS charge controller 1 Place the charge controller on the PV pole with cable glands facing downwards If you purchased a top of pole mounting structure by Western Co code WTP55 or WTP20 this is already prepared to house SPB LS 2 Execute the wiring of lamp PV module and battery as in the diagram on page 2 Together with SPB LS we supply all necessary cables to make the internal connections of PV street lamp 3 You must set the batteries configuration Move switch No 5 to ON pos
9. 0 24v Vch 0 48V VIb compensation with SW_5 gt OFF see Graph 2 Vremlb S8mV A 58mv A Voltage of day detection settable Vday 6ssv 1136v Voltage of night detection Vnight Vday 0 8V____ Vnight 448v asv Self consumption as 17m 177m Ambient temperature Tamb tC SC tC SOC IP protection degree 6 o Weight tog ogg oo 160x135 H6S 160x170 H6S This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl lt WESTERN CO SPB LS Manuale Utente Ei a Rev 1 2 NLA ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS User Man ual a 14 01 2013 Warranty Western Co Srl guarantees the good quality and good design of its own Products obliging itself during the warranty period of 5 five years to repair or replace at its sole discretion for free those defective parts owing to poor quality of material or defect in workmanship The defective product must be returned to Western Co Srl or to the company delegated by Western Co to make product support at customer s expenses together with a copy of the invoice both for repairing and warranty replacement The costs of re installation of the equipment will be borne by the customer Western Co srl will bear the transport expen
10. ECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS User Man ual a 14 01 2013 Scelta del modulo fotovoltaico Il regolatore di carica SPB LS grazie al circuito di ricarica con MPPT permette di impiegare una ampia gamma di moduli fotovoltaici garantendo lo sfruttamento ottimale di tutta la potenza Il modulo PV va scelto a seconda della tensione nominale della batteria e rispettando i vincoli dell ingresso pannello del SPB LS massima tensione a circuito aperto 100V e massima potenza di pannello 225W con batteria a 12V e 450W con batteria 24V Tensione nominale Caratteristiche moduli PV batteria Vmp tensione alla massima potenza a T 25 C gt sa Da Voc tensione circuito aperto a T 10 C lt 100V Tensione nominale Pmax massima potenza a 25 C lt 225W batte ria 1 2V Consigliamo moduli al silicio mono o poly cristallino con numero di celle da minimo 36 a massimo 144 celle Vmp tensione alla massima potenza a T 25 C gt Voc tensione circuito aperto a T 10 C lt 100V Tensione nominale Pmax Massima potenza a 25 C lt 450W batteria 24V Consigliamo moduli al silicio mono o poly cristallino con numero di celle da minimo 72 a massimo 144 celle Installazione regolatore SPB LS 1 Posizionare il regolatore sul palo fotovoltaico con i pressa cavo rivolti verso il basso Se avete acquistato una struttura testa palo della Western Co tipo WTP55 o WTP20 questa gi predisposta per alloggiare il regolatore SPB LS
11. NI n VIN m CHARGE REGULATOR FOR PV LIGHTING SYSTEMS b Devi d i ud TIENE Cog 5 5 c mi D pr I dica E ci g BI 8 si ul i s am a GITE POR PMR la es B i i Rioni D socz ds D 7 dis j scsi aT le mori fa So n pe III eli RI pleno n bi i 7 SPB LS is a charge regulator for the charge of batteries from PV module it has been specially designed for the use in off grid PV lighting systems PV street lamp The charge controller code SPB LS is housed inside a metal box that is protected from water IP66 degree therefore it can be installed directly on the PV pole without having to add additional protections The charge circuit from PV module has got an efficient algorithm for the search of the maximum power point MPPT that is capable of operating over an extended field of voltages It is allowed a maximum voltage on the PV module up to 100V The regulator can charge either 12V Pb batteries or 24V Pb batteries On power ON SPB LS automatically recognizes if the battery is at 12V or 24V and it automatically adjusts the charge thresholds The regulator automatically manages the power on and off of the lamp At dusk when the voltage of the PV module drops below the Vnight threshold the charge controller switches on the lamp and keeps it on for a number of hours that can be set by the user the default setting is 8 hours You can also set some programs for lamp s power on with working
12. RN CO SLI ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS User Manual A 01 2013 Dimensions 160 ka 1 1 L 50cm TEMPERATURE SENSE cables supplied LAMP CABLE HO RN F 3x1 5 L380Cm 1xNOFVWK 1x4BLAK L35Cm OD SO Cable for battery serial parallel connection 1lxND7VK 1x4RED L35Cm Lilife _____i M lt WESTERN CO SPB LS Manuale Utente E Rev 1 2 ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS User Man ual 14 01 2013 Graph 1 Graph 2 Charge voltage versus battery temperature Offset Vch and Vib versus Ibatt and Iload with SW_7 gt OFF battery distence 10mt 46 50 dVch dVib 0 96 r dVch dVIb V Vcharge V 12V x2 24V 25 0 30 0 35 0 K yl x yl Temp C Ibatt Iload A TECHNICAL FEATURES po ___ 12Vbatterynominal voltage 24V battery nominal voltage _ __ Min Typ Max Min Typ Moa Open circuit voltage pan 20v 100v dov 10v Panel current pan A OBA ax panel power emer __ a ff toad output voltage od Mba trani Charge voltage at 25 C SW_6 gt SEAL 14 44V 28 88V LA 6 gt FLOOD 14 EN 29 e Tbatt see Graph 1 Low battery voltage SW_5 gt ON SW_7 gt ON 12 00V 24 00V SW_7 gt OFF 11 52V 23 04V Vch compensation with SW_5 gt OFF see Graph 2 Vremch 58mVv A 58mvA Low battery output voltage at 25 C Vout_Ib Vch
13. ch the power delivered by the PV module is maximum realizing what is indicated in the technical literature with the acronym MPPT aN Maximum Power Point Tracking In addition it manages the battery charge by reducing the current delivered to the battery when Vgarr voltage exceeds its charging voltage Ven 2 Blocking diode it is needed to avoid that during the night when the PV module is not lighted this can absorb current from the battery 3 Circuit for the load control it switches ON OFF the load according to the program set by the user it commands the Dimmer signaling and it disconnects the load in case of low battery or overload 4 Microcontroller it controls the whole circuit it measures currents and voltages of PV module battery and load it performs the MPPT algorithm VBATT Q VLOAD ce ILOAD r VVVVVVVVVVVVVVVPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPIV BHR BREE HEHE BRR RRR eee eee eee EEHEHE x O Q Q verse oe 3 O ia A NIEIEEEEEEEEOD Fig 2 Principle diagram This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl Rev 1 2 lt WESTERN CO SPB LS Manuale Utente hosted ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS User Man ual VI VIN na Choice of PV module SPB LS charge controller thanks to MPPT charge allows to use a
14. er to use all the daily energy produced by the module without the risk that the system goes into low battery protection The self management algorithm sets the lamp on for 12 hours but can increase or decrease the number of hours at low flow as in following table This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl Rev 1 2 14 01 2013 WESTERN CO SPB LS Manuale Utente ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS User Man ual At the activation of Self management SPB ET 199 09 LS GSM sets ProgTimer sida sit a e If the system detects a few days of good weather x EET 0099 it increases the hours at maximum flux dii 12 13 14 15 16 after 1 day ETIT i2 13 14 15 16 after 2 days 2009 N VIN m eee e 2 13 14 15 16 Maximum If the system detects a few days of bad weather LAAARR AAA it decreases the hours at maximum flux ante a 215 14 1 16 after 1 day TFL 213 14 15 16 after 2 days Tore 213 14 15 Te after 3 days 1099 2 13 14 15 16 Minimum Working SPB LS is a PV charge controller for either electrochemical sealed batteries SEAL or flooded lead acid FLOOD Fig 1 shows a principle diagram 1 Charge circuit it adapts Vpan and Ipan respectively voltage and current of PV module in order to search the condition in whi
15. eserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl lt WESTERN CO SPB LS Manuale Utente Ei a Rev 1 2 NLA ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS User Man ual a 14 01 2013 Garanzia di legge Western Co srl garantisce la buona qualita e la buona costruzione dei Prodotti obbligandosi durante il periodo di garanzia di 5 cinque anni a riparare o sostituire a sua sola discrezione gratuitamente quelle parti che per cattiva qualita del materiale o per difetto di lavorazione si dimostrassero difettose Il prodotto difettoso dovr essere rispedito alla Western Co srl o a societ delegata dalla Western Co srl a fare assistenza sul prodotto a spese del cliente assieme ad una copia della fattura di vendita sia per la riparazione che la sostituzione garantita costi di re installazione del materiale saranno a carico del cliente La Western Co srl sosterr le spese di re spedizione del prodotto riparato o sostituito La garanzia non copre i Prodotti che in base a nostra discrezione risultino difettosi a causa di naturale logoramento che presentino guasti causati da imperizia o negligenza del cliente da imperfetta installazione da manomissioni o interventi diversi dalle istruzioni da noi fornite La garanzia decade altres in caso di danni derivanti da trasporto e o cattiva conservazione del prodotto causa di forza
16. h aspetter la notte successiva per riprovare 3 flash ogni 2 2 secondi protezione di sovratemperatura carico disattivo e circuito di ricarica disattivato occorre attendere che la temperatura interna al contenitore diminuisca dopodich la protezione si disattiva 4 flash ogni 2 2 secondi protezione di sovratensione circuito di ricarica disattivato la protezione si disattiver quando la tensione di oahi ia rientra nel rane SCN ae Bor Oltre all indicazione della tensione nominale di funzionamento del RA i sistema se ogni 4 3sec si spegne per un attimo indica che la sonda NTC e disconnessa La Vch equivale a quella per 60 C Programmazione LOAD i Bio i AUTOMA AGEMENT s d a Caen i eseguita attraverso i configuration i switch Il simbolo luna in corrispondenza della prima ora indica l evento crepuscolo Ogni casellina rappresenta un ora da 1 a 16 se colorata interamente o parzialmente l uscita LOAD risulter attiva l uscita Dimmer sar attiva solo se la casellina colorata parzialmente a rappresentare la riduzione di flusso La prima configurazione AUTOMANAGEMENT provvede automaticamente a variare le ore di ridotta in base all energia disponibile in batteria Nella configurazione 24 HOURS TO DAY il LOAD sempre attivo indipendentemente se giorno o notte Quando l impostazione self management in ON il regolatore SPB LS sceglie in modo automatico l impostazione ProgTime
17. he SAC LU Ww Lu Wy Lu oc E T oe Lu A gt 3 Lu H BATTERY street lamp W LIGHT Fig 2 Wiring scheme PV Module 12V BATTERY SYSTEM 24V BATTERY SYSTEM This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl Rev 1 2 14 01 2013 lt WESTERN CO SPB LS Manuale Utente ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS U Ser M anud VI na VIN a Visualizzazioni e protezioni Led PV Funzionalit Il numero di lampeggi effettuati indica l intensit di corrente dal Verde modulo fotovoltaico 1 1 flash con pausa di 4 3 sec 0 5A lt PV current lt 1 5A 2 flash con pausa di 4 3 sec 1 5A lt PV current lt 2 5A lt gt cosi via valori intermedi ees intermedi 13 flash con pausa di 4 3 sec 12 5A lt PV current lt 13 5A 1 13 AVOUT eso E Se sempre acceso indica un anomalia del sistema che richiede un 1 flash ogni 2 2 secondi protezione di Low Battery attiva carico disattivato occorre attendere che il modulo PV ricarichi la batteria dopodich la protezione si disattiva condizione di normale funzionamento 2 flash ogni 2 2 secondi protezione di sovraccarico attiva carico disattivato dopo circa due minuti si autoripristina esegue tre tentativi in sequenza dopodic
18. ition if the batteries are located close to the regulator and to OFF position if batteries are far from the controller Move switch No 6 selecting the kind of battery in use to adapt the correct charging voltage Ven You have to set SEAL configuration if you use either VRLM sealed batteries or GEL while you have to choose FLOOD configuration if you use flooded lead acid batteries Move switch No 7 selecting the depth of discharge of the battery bank between 30 and 70 This determines the system autonomy in case of no sun condition with 70 you will have a greater autonomy but the expected life of the battery bank reduces We generally recommend a DoD of 30 Using the switches n 1 2 3 4 set the load management proper for your own application System testing Once you put in function the system make the testing e With the PV module exposed to sunrays verify that SPB LS charges the battery by observing the LED PV that indicates the intensity of current from the PV module It will flash as described in the table e Verify that the 12V 24V LED does not indicate the disconnection of the NTC probe see table above e Check the correct activation of the load moving temporarily all switches 4 5 6 7 to OFF position load always on otherwise you can simulate the night either disconnecting temporarily one of the wires of the PV module or obscuring the PV module with a covering panel SPB LS Manuale Utente WESTE
19. maggiore o eventi catastrofici gelo per temperature inferiori a 20 C incendio inondazioni fulmini atti vandalici ecc Tutte le sopraccitate garanzie sono il solo ed esclusivo accordo che soprassiede ogni altra proposta o accordo verbale o scritto e ogni altra comunicazione fatta tra il produttore e l acquirente in rispetto a quanto sopra Per qualsiasi controversia il Foro competente Ascoli Piceno Smaltimento dei rifiuti La Western Co in qualit di produttore del dispositivo elettrico descritto nel presente manuale ed in conformit al D L 25 07 05 n 151 informa l acquirente che questo prodotto una volta dismesso deve essere consegnato ad un centro di raccolta autorizzato oppure in caso di acquisto di apparecchiatura equivalente pu essere riconsegnato a titolo gratuito al distributore della apparecchiatura nuova Le sanzioni per chi abusivamente si libera di un rifiuto elettronico saranno applicate dalle singole amministrazioni comunali MADE IN ITALY Western Co s r l Via Pasubio 1 San Benedetto del Tronto AP 63074 Italy info western it WWWw western it This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl lt WESTERN CO SPB LS Manuale Utente ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB L S User Man ual Rev 1 2 14 01 2013
20. n indichi la disconnessione della sonda NTC vedi tabella precedente e Verificare la corretta accensione del carico spostando momentaneamente gli switch 4 5 6 7 tutti a OFF carico sempre acceso oppure possibile simulare la notte scollegando temporaneamente uno dei fili del modulo PV o ancora oscurando il modulo PV con un pannello coprente This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl Rev 1 2 lt WESTERN CO SPB LS Manuale Utente hosted ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS User Man ual NI VIN m Dimensioni 160 l 1 1 L 50cm TEMPERATURE SENSE cables supplied LAMP CABLE HO RN F 3x1 5 L380Cm 1xNOFVWK 1x4BLAK L35Cm OD SO Cable for battery serial parallel connection 1xNDOFVK 1x4RED LoSCm KS This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl WE TERN CO SPB LS Manuale Utente E Rev 1 2 STIA Ne aecmnonie EQUIPMENTS SOLAR SYSTEMS SPB LS User Man ual a 14 01 2013 Grafico 1 Grafico 2 Charge voltage versus battery temperature Offset Vch and Vib versus Ibatt and Iload with SW_7 gt OFF battery distence 10mt 46 50
21. pada che prevedono delle ore di funzionamento a potenza ridotta dimmer in questo modo si pu controllare accuratamente il consumo della lampada in modo che rientrino nei vincoli di dimensionamento del sistema stad alone FEATURES e 12V 24V tensione di batteria e 225W 450W max PV per sistemi 12V 24V e Carica MPPT con tensione del modulo fino a 100V e Diodo di blocco integrato e Batterie Sealed or Flooded Lead Acid e Compensazione in temperature della tensione di carica e Protezione di Low Battery e Protezione di Over temperature e Protezione di Overload e Protezione inversion polarit batteria e Comanda l accensione della lampada a flusso pieno e a flusso ridotto e IP66 per applicazioni all esterno GEL AGM FLOOD DISCHARGE PROTECTION NIGHTLIGHT FUNCTION This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl SZ WESTERN CO ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS Manuale Utente SPB LS User Manual Rev 1 2 14 01 2013 VI n VIN Da Wiring SERBO LIE a TA REMOTI z SIONI get Aas Sn Boy onl i felt LOAD LED Configuration switch OU DIMMER LED amp a in Italy TR i E Ut ek A m 9 a WUD D Mi pee 5 sesti Fe a it ut i ca RE FM prof hai t
22. r Un algoritmo proprietario della Western Co basato sull energia prodotta giornalmente dal modulo PV setta il ProgTimer in modo da usare tutta l energia giornaliera prodotta dal modulo PV riducendo il rischio che il sistema vada in protezione di low battery L algoritmo self management imposta 12 ore di accensione lampada ma incrementa o decrementa il numero di ore in riduzione di flusso come nella seguente tabella La programmazione del carico This document is the property of WESTERN CO Srl All rights are reserved Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO Srl Rev 1 2 WESTERN CO SPB LS Manuale Utente Li ELECTRONIC EQUIPMENTS SOLAR SYSTEMS SPB LS U ser M anuqd Alla prima attivazione del Self management l SPB LS seta il ProgTimer Se il sistema incontra alcuni giorni di bel tempo allora questo incrementa il numero di ore di i alli dopo 1 day accensione alla massima luminosit VI VIN Da dopo 2 days dopo 3 days 6 Se il sistema incontra alcuni giorno di cattivo ATRIA 09 tempo questo decrementa le ore alla massima i alj lumiosit after 1 day 1 1 e after 2 days e 6 after 3 days Minimum Funzionamento L SPB LS un regolatore di carica da moduli fotovoltaici per batterie elettrochimiche al piombo di tipo ermetico SEAL o ad acido libero FLOOD In fig 1
23. rotection load OFF and deactivated charge circuit wait that the temperature inside the box decreases then the protection will deactivate 4 flashes every 2 2 seconds Overvoltage protection the charge circuit is deactivated the protection will deactivate when the Dater voltage goes back wiin its operative range 12v In addition to the working nominal voltage of the system if every 4 3 seconds it switches off for a moment this means that the NTC probe is disconnected Vch is equivalent to that for 60 C Timer Program LOAD programming Load programming can be executed Pa i ne 3 through configuration switches AUTO MANAGEMENT i PLETE EE The moon symbol in 3 correspondence of the first hour indicates the sunset event Each box represents an hour from 1 to 16 if it is entirely or partially colored the LOAD output is active the Dimmer output is active only if the box is partially colored to represent the flux reduction The first configuration AUTOMANAGEMENT will automatically change the hours of reduced flux according to the energy available inside the battery In the configuration 24 HOURS TO DAY the LOAD is always active regardless of whether day or night when self management is in ON the SPB LS GSM chooses the most suitable timer A Western Co proprietary algorithm based on the daily energy produced by the PV module it sets the ProgTimer in ord
24. ses of the repaired or replaced product The warranty does not cover Products that according to our discretion are defective due to natural wear showing damages caused by incompetence or negligence of the customer imperfect installation by tampering or other interventions different by the instructions supplied by us The warranty is not valid also in case of damages coming from transport and or incorrect storage of the product force majeure or catastrophic events frost to temperatures below 20 C fire flood lightning vandalism and so on All of the abovementioned guarantees are the sole and exclusive agreement which supersedes any proposal or agreement oral or written and any other communication made between the manufacturer and the purchaser in respect of the above For any dispute the jurisdiction is Ascoli Piceno Waste disposal Western Co as manufacturer of the electrical device herein described and in accordance with DL 07 25 2005 n 151 informs the consumer that this product once abandoned must be delivered to an authorized collection center or in case of purchase of an equivalent equipment it can be returned free of charge to the distributor of the new equipment The penalties will be applied by individual Municipalities MADE IN ITALY Western Co s r l Via Pasubio 1 San Benedetto del Tronto AP 63074 Italy info western it www western it This document is the property of WESTERN CO Srl