1. 1 69161 oz anie Enter 01 14 2004 11 30pm 185 8 Figure 4 Weight Display Mode BALANCES COM OPERATION INSTRUCTIONS 02 TARE WEIGHT NOTE Due to the scale s sensitivity we recommend using the REWEIGH function prior to setting the TARE weight in order to eliminate any operator interference with the item to be tared out There are two ways to manually enter a tare weight such as the weight of a wheelchair shoes etc press MENU 1 and select option 02 Tare Weight or press TARE 9 If there is no weight on the scale platform value displayed is zero and there is no tare and the user presses the TARE button 9 the Tare Weight window appears and prompts the user to enter the TARE value and to press ENTER NOTE The tare weight must be entered using the following increments 4oz 0 2lb lb The value entered will display in minus After the TARE has been entered the scale goes back to normal operation This TARE value is stored in memory until changed or cleared Important The TARE weight cannot exceed 200 Ib The number that is to be changed will flash and will move from the left to the right after the appropriate number was LB OZ entered or by using the 4 key left Exit and the w key right TARE display indicates the weight 01 14 2004 that has been tared 05 1 2o Figure 5 Tare Weight Automatic Tare The user can set a tare weight by pressing the TARE button 9 while there is a
2. v AY to change Enter 01 R glage de l Heure et de la Date L utilisateur peut r gler l heure et la date par l interm diaire du clavier Pour mettre l appareil l heure passez du chiffre des heures celui des minutes et puis des secondes l aide des touches 04 32 01 fl ch es et v et tapez au fur et mesure les valeurs zx correspondantes sur le clavier Pour passer la ligne AM PM AM PM matin soir ou apr s midi appuyez une fois sur la touche Avtochange Enter Entr e ENTER 31 BALANCES COM MODE DE FONCTIONNEMENT AV 02 10 05 03 to change Enter Version uPSD 10625 PIC Ver 10623 LoadCell 10622 Last Update 01 15 04 Exit 06 01 02 Enter TEST DE SYSTEME Test des Piles Connexion USB Connection is OK R glez la date en utilisant les touches fl ch es A v et tapez les valeurs sur le clavier Cet cran affiche la version du logiciel install sur la balance gt 02 USB Connection 03 Ul Test v A Y to change Enter La balance fait figurer la dur e de vie estim e restante avant que les piles actuelles n aient besoin d tre remplac es REMARQUE pour accomplir le test des piles la balance doit tre aliment e seulement par les piles D branchez la du secteur CA avant d effectuer ce test La balance teste la connexion avec le PC et affiche le message Connection is OK Connexion correcte ou NO Connection Pas
3. Description Qty 1 1109401 0 DISPLAY ASSEMBLY 1 2 2033701 0 MAIN BOARD TO JUNCTION BOX CABLE 1 3 2266901 0 TILT MECHANISM ASSEMBLY 1 4 3822601 0 SMALL REAR COVER 1 5 3822901 0 HANDLE 1 6 3822101 0 HANDRAIL 1 7 381 7001 0 ADAPTER HOLDER 1 8 SHEET METAL SCREW 8 1 2 11 9 HEALTH O METER LABEL 1 10 MODEL LABEL 1 11 SOCKET HEAD CAP SCREW NC5 16 3 4 4 12 3822001 0 BASE ASSEMBLY 1 13 2267201 0 RUBBER WHEEL ASSEMBLY 2 14 2138901 0 CON DIG BOARD 1 15 PHIL PAN HEAD SCREW NC6 1 4 1 16 3822401 0 BOTTOM COVER 1 17 2266701 0 PLASTIC FOOT NC3 8 ASSEMBLY 4 18 SOCKET HEAD CAP SCREW NC5 16 18 3 4 8 19 1304202 0 LOAD CELL 4 20 3823001 0 PVC MAT 1 21 SOCKET HEAD CAP SCREW NC1 4 3 4 10 22 401305 CABLE CLIP 4 23 LEFT SIDE BAR 1 24 RIGHT SIDE BAR 1 25 3822501 0 FRONT COVER 1 26 SOCKET HEAD SCREW NC3 8 1 5 2 27 PHIL PAN HEAD SCREW NC8 5 16 6 28 3822701 0 REAR COVER 1 29 420988 ADAPTER UNIT 6VDC 120VAC 1 30 CABLE TIE CV100 1 31 411192 KEYPAD 800LB 1 32 HEAD TOP 1 33 LCD WINDOW 1 34 LCD BOARD 1 35 WN1412 CROSS HEAD SCREW K22L6 4 36 DISPLAY TO EAGLE P C B CABLE 1 37 WN1412 CROSS HEAD SCREW K30L6 4 38 EAGLE BOARD 1 39 HEAD BASE 1 40 PHIL PAN HEAD SCREW NC6 32 3 8 6 41 MODEL LABEL 1 42 3245801 0 INPUT OUTPUT PORTS LABEL 1 43 PHIL PAN HEAD SCREW NC4 40 1 4 1 44 3822801 0 BATTERY COVER 1 45 400152 RUBBER O RING 1 46 2033801 0 BATTERY HOLDER 1 19 BALANCES COM WARRANTY LIMITED WARRANTY What does the War
4. Si los Yes valores no son introducidos solamente el peso es almacenado AYto change Enter NOTA Estos valores no pueden ser conservados por el numero de ID 53 BALANCES COM INSTRUCCIONES DE OPERACION 02 Exhibir Altura e ID Yes AY to change 01 14 2004 ZERO 11 30pm 5 4 Ib Height 6100 0 Oin ID 981723737123 03 Solicitaci n de Altura Yes AY to change Enter 04 Solicitaci n de ID Yes AY to change Enter Enter 01 14 2004 ZERO Cuando esta opci n es activada el usuario es solicitado a introducir la altura del paciente despu s de cada pesaje Cuando esta opci n es activada el usuario es solicitado a introducir el numero de ID del paciente despu s de cada pesaje 54 Cuando el usuario elige presentar la altura y el ID del paciente estos ser n exhibidos en la parte inferior de la pantalla Recomendamos usar esta funci n para asegurarse que el ID y altura correctos fueron introducidos 11 30pm Ob 01 14 2004 1534 b 11 30pm Please enter Height 0800 O Oin av to change Enter 01 14 2004 150321 Please enter ID 2345872336 Enter 11 30pm AY to change BALANCES COM MANTENIMIENTO GENERAL Esta secci n provee instrucciones para mantenimiento limpieza soluci n de problemas y piezas reemplazables por el operador para la Balanza Clinica Electr nica Pro Plus Modelo 2101KL Otras operaciones de mantenimient
5. change Enter REMARQUE ces valeurs ne peuvent pas tre retenues par le biais du num ro ID 33 BALANCES COM MODE DE FONCTIONNEMENT 02 Affichage Hauteur et ID Quand l utilisateur choisit d afficher la hauteur et le num ro d identification ID du Yes patient celui ci s affichera au bas de l cran Nous Avtochange Enter recommandons l application de cette fonction pour v rifier l exactitude du num ro ID et de la hauteur enregistr s pour le patient 01 14 2004 11 30pm 01 14 2004 11 30pm ZERO 3 ZERO S 4 Ib 3 Height 6100 0 Oin 5 A ID 981723737123 4 Ib 03 Message quide pour la Hauteur Quand cette option est 01 14 2004 11 30pm activ e un message guide 1 533 demandera a l utilisateur 4 Ib Yes d introduire la hauteur du Please enter Height patient apres chaque pes e 01 00 O Oin AY to change Enter 04 Message guide pour le num ro d identification ID av to change Enter Quand cette option est 01 14 2004 11 30pm activ e un message guide 1 53 3 demandera l utilisateur 4 Ib Yes d introduire le num ro Please enter ID d identification du patient 2345872336 avtochange Enter apr s chaque pes e avtochange Enter 34 BALANCES COM MAINTENANCE GENERALITES Ce chapitre fournit les instructions pour la maintenance le nettoyage la localisation des pannes et indique les pieces remplacables par l op rateur pour la balance clinique lectronique Pro Plus mod le 2101KL Toutes op rat
6. 02 Conexi n USB La balanza testara la conexi n al PC y exhibira el mensaje Connection is OK o NO Connection Si aparece NO Connection verifique sus conexiones USB en la balanza y en su PC y haga de nuevo la prueba de la is OK on 2 a gt 5 conexi n Refi rase al personal de servicio calificado si el problema persiste Connection 52 BALANCES COM INSTRUCCIONES DE OPERACION 03 Prueba Ul La balanza tiene una rutina de diagn stico donde prueba la funcionalidad del hardware LCD teclado del Interfaz del Usuario Ul Con el fin de realizar esto el usuario tiene que 1 presionar todas las teclas segun los mensajes que aparecen Es en la pantalla Please Press Si el comando solicitado no fue recibido o un bot n equivocado fue presionado el siguiente mensaje ser Please press the presentado button marked 1 you have 10 seconds Exit Si despu s de 10 segundos el comando solicitado no haya sido recibido el siguiente mensaje ser exhibido Si aparece UI Error UI Error Failure refi rase al personal de servicio calificado Failure 07 CONFIGURACIONES DEL USUARIO 02 Disp Height amp ID 03 Prompt For Height v Exit 04 Prompt For ID 05 Exit 01 Conservar los Valores Introducidos Esta opci n permite al usuario usar los mismos valores de ID altura y TARA entre pesajes Si esta opci n es desactivada el usuario debe re entrar estos valores para cada lectura
7. cambiado o borrado Importante El peso TARA no puede exceder 200 lb El numero que debe ser cambiado parpadeara y pasara de la izquierda a la derecha despu s que el numero LB OZ apropiado haya sido introducido o D usando la tecla 4 izquierda y la tecla Exit v derecha El display TARE indica el peso que ha 01 14 2004 sido disminuido 0 3 LB 1 2 OZ Figura 5 Peso Tara Tara Automatica El usuario puede establecer un peso tara presionando el bot6n TARE 9 mientras hay un peso en la plataforma de la balanza El display pasa a cero y la TARA sera exhibida para indicar que hay un valor tara en la memoria como presentado en la Figura 5 arriba Removiendo la Tara Una presi n adicional en el bot6n TARE apagara el valor tara de la memoria TARA desaparecera del display y la balanza continua la operaci n normal 03 ADMINISTRACI N DE DATOS La balanza administra los datos del paciente incluyendo ID peso altura tara y BMI El valor es almacenado en la memoria o transferido al PC Esta funci n es realizada abri ndose un nuevo archivo de datos ABRIENDO UN NUEVO ARCHIVO DE DATOS 1 Presione el bot n ID 7 2 Usando el teclado entre el n mero de identificaci n 3 Presione ENTER 47 BALANCES COM INSTRUCCIONES DE OPERACION Esta balanza calculara tambi n el indice de Masa del Cuerpo Body Mass Index BMI CALCULANDO EL BMI 1 Coloque el paciente en la plataforma de la balanza 2 Presione el bot
8. from TARE the weight on the platform Also releases tare weight returns display to zero EXIT Reverts back one step when in the menu and data entry modes ENTER Used to enter commands and values into the scale 5 BALANCES COM OPERATION INSTRUCTIONS MENU In the menu screen the user can set preferences and or instruct the scale how to handle stored data The menu can be navigated using the up and down keys 4 v or by entering the associated menu position number with the keypad The menu has a roll over way of working when the user scrolls to the bottom of the menu and presses the down button it will return to the top of the menu Indicator of menu position Scroll th hth croll thro e men 02 Tare Weight d options with a and w keys 03 Data Management ptions with v key Exit Active menu option is marked by inverted color 04 Scale Settings 05 System Settings 06 System Test 07 User Settings 08 Exit Figure 3 Main Menu 01 WEIGHT DISPLAY MODE only applies to pound values NOT the metric values The user can set the screen display value in either fraction of pound 74 72 or Ib in pounds and ounces resolution of 4 ounces or in decimals resolution of 0 2 Ib When kg is selected as the units of use these settings have no effect The mode that is selected is used through all the screens 01 14 2004 11 30pm 18541 01 14 2004 11 30pm 02 Pounds amp Ounces
9. n BMI 2 3 La balanza le solicita entrar la altura del paciente Use el teclado para entrar la altura en 1 4 1 1 4 2 1 2 3 3 4 o incrementos de 1 cm use pulgadas para peso en Ib cm para kg Presione ENTER 4 En el display aparecera el BMI del paciente La balanza ofrece dos opciones para administrar la informacion transferir descargar los valores o almacenarlos La primera opci n descarga transfiere automaticamente los valores a su PC La segunda opci n almacena el valor en la memoria La capacidad maxima de la balanza es de 270 archivos con datos distintos gt 02 Store In memory 03 Do not store data v AY to change Enter 04 Transfer now 05 Clear memory Descarga Automatica Descarga Automatica es la opci n predeterminada y transferira el valor al PC asi que el paciente baje de la balanza o cuando el usuario presiona el bot n Updated HOLD RELEASE si estuviera mantenido en HOLD Si ningun PC esta conectado el valor no es transferido y no es almacenado y sera perdido despu s que la carga es removida de la balanza 2 Almacenar en la memoria El valor es almacenado en la memoria para ser m s tarde descargado al PC Updated Si la memoria est cerca de estar llena el usuario ser 02 Clear memory informado y le ser dada la Exit opci n de transferir todos los valores al PC o limpiar todos los valores de la memoria 3 No almacenar datos Todos los datos sera
10. o un documento que demuestre prueba de la compra Llame 1 800 638 3722 or 1 708 598 9100 para recibir un n mero de autorizaci n para retorno Adjunte prueba de la compra al producto con defecto junto con su nombre direcci n n mero de tel fono de d a y descripci n del problema Empaquete el producto cuidadosamente y env elo con transporte y seguro pagados por adelantado a Pelstar LLC Atenci n R A Departamento de Reparaci n 7400 W 100th Place Bridgeview IL 60455 Si su balanza no est cubierta por garant a o ha sido danificada un presupuesto de los costos de reparaci n o reemplazo ser prove do a usted para aprobaci n antes del mantenimiento o reemplazo Pelstar LLC 7400 West 100th Place Bridgeview IL 60455 1 800 638 3722 or 1 708 598 9100 www healthometermedical com Los productos Health o meter ProPlus son fabricados proyectados y de propiedad de Pelstar LLC Health o meter es una marca registrada de Sunbeam Products Inc Boca Raton FL 33431 ProPlus es una marca registrada de Pelstar LLC Patentes Pendiente 60
11. tocar o sacudir la balanza hasta que el Calibration Calibraci n proceso de calibraci n se termine factor X XXXXX 8 Presione ENTER Calibration Calibraci n Por favor limpie la balanza 9 Remueva el peso de la plataforma de la balanza Rebooting Reiniciando el sistema Por favor espere 10 Espere hasta que la balanza reasuma operaci n Health O Meter normal Pro Plus VISTA DETALLADA DE LA BALANZA 57 BALANCES COM VISTA DETALLADA DE LA BALANZA continuaci n Q 9 QQQQA Q 56 BALANCES COM LISTA DE PIEZAS No Llave Parte No Descripci n Cde 1 1109401 0 UNIDAD DE DISPLAY 1 2 2033701 0 CABLE DE JUNCI N DE LA CAJA AL TABLERO 1 PRINCIPAL 3 2266901 0 UNIDAD DEL MECANISMO DE INCLINACI N 1 4 3822601 0 PEQUE A TAPA TRASERA 1 5 3822901 0 1 6 3822101 0 1 7 3817001 0 SOPORTE DEL ADAPTADOR 1 8 TORNILLO PARA LAMINA DE METAL 8 1 2 11 9 ETIQUETA HEALTH O METER 1 10 ETIQUETA DEL MODELO 1 11 TORNILLO CABEZA CAP DEL S CALO NC5 16 3 4 4 12 3822001 0 UNIDAD DE LA BASE 1 13 2267201 0 UNIDAD DE LA RUEDA DE GOMA 2 14 2138901 0 TABLERO CON DIG 1 15 TORNILLO CABEZA PHIL PAN NC6 1 4 1 16 3822401 0 TAPA INFERIOR 1 17 2266701 0 UNIDAD DE PIE DE PLASTICO NC3 8 4 18 TORNILLO CABEZA CAP DEL SOCALO NC5 16
12. 18 3 4 8 19 1304202 0 CELULA DE CARGA 4 20 3823001 0 ESTERA DE PVC 1 21 TORNILLO CABEZA CAP DEL SOCALO NC1 4 3 4 10 22 401305 TERMINAL DEL CABLE 4 23 BARRA DEL LADO IZOUIERDO 1 24 BARRA DEL LADO DERECHO 1 25 3822501 0 TAPA DELANTERA 1 26 TORNILLO CABEZA DE SOCALO NC3 8 1 5 2 27 TORNILLO CABEZA PHIL PAN NC8 5 16 6 28 3822701 0 TAPA TRASERA 1 29 420988 UNIDAD DEL ADAPTADOR 6VDC 120VAC 1 30 CABLE DE CONEXI N CV100 1 31 411192 TECLADO 800LB 1 32 TOPO DE LA CABEZA 1 33 VENTANA LCD 1 34 TABLERO LCD 1 35 WN1412 TORNILLO DE CABEZA CRUZADA K22L6 4 36 CABLE PARA DISPLAY DEL P C B EAGLE 1 37 WN1412 TORNILLO DE CABEZA CRUZADA K30L6 4 38 TABLERO EAGLE 1 39 CABEZA DE LA BASE 1 40 TORNILLO CABEZA PHIL PAN NC6 32 3 8 6 41 ETIQUETA DEL MODELO 1 42 3245801 0 ETIQUETA DE PUERTOS DE ENTRADA SALIDA 1 43 TORNILLO CABEZA PHIL PAN NC4 40 1 4 1 44 3822801 0 TAPA DE LA BATER A 1 45 400152 ANILLO O DE GOMA 1 46 2033801 0 SOPORTE DE LA BATER A 1 59 BALANCES COM GARANTIA GARANTIA LIMITADA Qu Cubre la Garant a Las balanzas de Pelstar LLC est n garantizadas a partir de la fecha de compra contra defectos de fabricaci n y mano de obra por un periodo de un 1 a o Si el funcionamiento del producto no fuese adecuado regrese el producto a Pelstar con fletes prepagados y en un embalaje adecuado Vea Para Obtener Servicio de Garant a abajo para de instrucciones Si el fabricante determinase la existencia de un d
13. 801 0 LOGEMENT DES PILES 1 39 BALANCES COM GARANTIE GARANTIE LIMITEE Que couvre la garantie A compter de la date d achat les p se personnes Pelstar LLC sont garantis contre les d fauts de mat riel ou de fabrication pour une p riode d un 1 an Renvoyez a Pelstar port pay et bien emball le produit qui fonctionne mal Si le fabricant constate un d faut de mat riel ou de fabrication le pese personne sera r par ou chang sans aucun frais pour le client Le remplacement se fera avec un produit ou composant neuf ou corrig Si le produit n est plus disponible le remplacement se fera par un appareil similaire d une valeur gale ou sup rieure Les frais de toutes les pieces r par es ou chang es sont couvertes seulement pour la p riode de garantie originale Qui est couvert par la garantie Le premier acheteur du produit doit avoir les pieces justificatives de l achat lui donnant droit au service de garantie Les concessionnaires ou les d taillants des produits Pelstar n ont pas le droit de modifier ou de changer les termes et conditions de cette garantie Ce que la garantie ne couvre pas Votre garantie ne couvre pas une usure normale des pi ces ou un dommage r sultant des l ments suivants n gligence ou mauvais usage du produit branchement sur un courant ou un voltage non appropri usage non conforme au mode d emploi abus comprenant le fait de trifouiller l appareil le dommage occasionn
14. AC adapter from the power source The scale will shut off Press On Off and the scale will switch to battery power NOTE If the set up procedure failed refer to the troubleshooting instructions If the problem is not corrected refer to qualified service personnel To adjust the display backlight and or contrast please refer to page 11 To change the display mode in pounds to fractions or decimals please refer to page 6 Replacing Batteries _ SCREW BATTERY COVER gt BATTERY HOLDER SCALE BATTERY CONNECTO BATTERY HOLDER CABLE CONNECTOR Figure 1 Replacing Batteries refer to the Parts List on page 19 for details on parts followed by GD Unplug the scale Remove the battery cover from the display assembly Disconnect battery holder cable connector from the scale battery connector Carefully remove the battery holder by sliding it out the display assembly Replace the batteries with new ones Carefully position the battery holder into the display assembly Plug the battery holder cable connector to the scale battery connector Attach the battery cover to the display assembly and install the screw POL SLR eoe cs To change the scale default units to kilograms or to deactivate the LB KG button please contact Technical Support at 1 800 638 3722 or 1 708 598 9100 We recommend the use of EVEREADY Energizer e2 batteries BALANCES COM OPERATION INSTRUCTIONS SNS 5 Press the ON OFF button
15. ARE 9 En l absence d objet sur la plateforme la valeur affich e est z ro il n y a pas de tare et si l utilisateur appuie sur la touche de la TARE 9 la fen tre du Poids de la Tare s ouvre et le guide pour introduire et valider la valeur de la TARE REMARQUE le poids de la tare est introduit par paliers de 402 0 21 746 La valeur introduite apparait avec le signe moins Ensuite la balance revient en position normale Cette valeur de TARE est m moris e jusqu au prochain changement ou effacement Important Le poids de la TARE ne peut pas d passer 200 lb Le chiffre a changer clignotera et le clignotement se d placera de gauche 0 5 1 2 droite apr s introduction du chiffre appropri l aide des touches VIB OZ indiquant les fleches 4 pour la Exit gauche et v pour la droite L affichage de la mention TARE 01 14 2004 indique que l objet a bien t tar 035 1 D Figure 5 Poids de la tare Tarage Automatique L utilisateur peut r gler le poids d une tare gr ce la touche correspondante TARE 9 tandis q un objet se trouve pos sur la plateforme de la balance L affichage se mettra z ro et la mention TARE sera affich e pour indiquer qu une valeur de tare est m moris e comme le montre la Figure 5 ci dessus Retrait de la Tare Une simple pression suppl mentaire sur la touche portant la mention TARE effacera la valeur de la tare qui se trouve actuellement en m moire la mentio
16. BALANCES COM Health o meter ro u 5 PRO PLUS ELECTRONIC HANDRAIL SCALE MODEL 2101KL BALANCE CLINIQUE ELECTRONIQUE PRO PLUS MODELE 2101KL BALANZA CLINICA ELECTRONICA PRO PLUS MODELO 2101KL OPERATION MANUAL MODE D EMPLOI MANUAL DE OPERACI N BALANCES COM PRO PLUS ELECTRONIC HANDRAIL SCALE MODEL 2101KL Thank YOU for your purchase of this product Please read this manual carefully and keep it handy for ready reference Merci d avoir achet ce produit Veuillez lire attentivement ce manuel et le garder a port e de main pour pouvoir le consulter a tout moment Gracias por la adquisici n de este producto Lea por favor este manual cuidadosamente y mant ngalo a su alcance para una pronta referencia ENGLISH 1 FRANCAIS co es 21 oc od 41 TABLE OF CONTENTS CAUTION AND WARNING daa 2 A EP o o ORA cule 2 SET UP Re 3 OPERATION ING TROCTIONS eme 4 MAINTENANCE GR 15 TROUBLESHOOTING aaa m 16 CALIBRATION PA H RYN Y licza ada dt 17 EXPLODED VIEW OF SCALE scsi ALLE ao 17 PARTS LIST P AGR 19 Ne a n 20 BALANCES COM CAUTION AND WARNING To prevent injury and damage to your scale pleas
17. CTIONNEMENT 4 9 Appuyez sur l interrupteur de Marche Arr t ON OFF pour allumer l appareil Attendez que les mentions 000Lb00oz et ZERO apparaissent sur le c t gauche de l cran num rique Demandez au patient de monter sur la balance La mention WEIGHING Pes e figurera a l cran jusqu ce que s affiche le poids de la personne Si vous souhaitez effectuer une nouvelle pes e sans faire descendre et remonter le patient sur la balance il vous suffit d appuyer sur la touche de repes e REWEIGH Faites ensuite descendre le patient de la balance REMARQUE La balance reviendra toujours par d faut aux derniers r glages et unit s utilis s 24 BALANCES COM MODE DE FONCTIONNEMENT fe O dE M Capacity 800 Ib x 2 Ib 363 kg x 100g Figure 2 Clavier TOUCHE DESCRIPTION FONCTION POWER Allume ON et teint OFF l appareil ZERO Met la balance z ro avant la pes e Maintient l affichage du poids de l objet pes et ce jusqu la HOLD RELEASE pression suivante de la touche qui effacera cette valeur de l cran Sert aussi faire d filer le menu vers le bas REWEIGH Permet de renouveler la pes e du patient sans le faire descendre de la balance Touche KG LB Permet de passer des kilogrammes aux livres et vice versa Sert aussi faire d filer le menu vers le haut 3 69 cent OD amp 0 MENU Donne acc s au menu de
18. Cell Error Existe un problema con una o m s de las c lulas de carga o el cable de las c lulas de carga est desconectado Verifique el cable de conexi n de las c lulas de carga en el display y puertos de montaje de la plataforma Si el problema no es corregido refi rase al personal de servicio calificado para reemplazar la pila defectuosa 56 BALANCES COM La calibraci n es realizada usando kg o lb segun las unidades de medida usadas al entrar en la trayectoria de calibraci n Acci n del Operador Display 1 Presione el bot n ON OFF y a seguir presione y Calibration Calibraci n mantenga presionado el bot n HOLD RELEASE Proceso durante 3 4 segundos 2 Presione ENTER Enter load weight Entre el peso de carga 600 0 3 Usando las teclas A v y o el teclado fije la carga de Zero calibration Calibraci n cero calibraci n para por lo menos 200 Ibs para mejores Por favor limpie la balanza resultados y mayor precisi n use un peso de 600 Ib Presione ENTER 4 Limpie la plataforma de la balanza y presione ENTER Zero calibration Calibraci n cero Por favor espere 5 Espere sin tocar o sacudir la balanza hasta que el Weight calibration proceso de calibraci n cero se termine Calibraci n del Peso Ponga XXX X 6 Cargue la plataforma de la escala con el peso Weight calibration requerido y presione ENTER Calibraci n del Peso Por favor espere Espere sin
19. DY Energizer e2 43 BALANCES COM INSTRUCCIONES DE OPERACION SNA 5 Presione el bot n ON OFF para activar la balanza Espera hasta que aparezca 000Lb00oz y ZERO en el lado izquierdo del display Pida al paciente que suba en la balanza El display deber mostrar WEIGHING hasta que el peso de la persona sea presentado Si usted desea repesar sin pedir al paciente que baje y suba otra vez a la balanza presione el bot n REWEIGH Pida al paciente que baje de la balanza NOTA La balanza siempre retornar a la configuraci n y unidades usadas por ltimo 44 BALANCES COM INSTRUCCIONES DE OPERACION Per O l Ml ua Capacity 800 Ib x 2 lb 363kg x 100g Figura 2 El Teclado iTEM DESCRIPCION FUNCION POWER Conecta ON y desconecta OFF la balanza ZERO Cera la balanza antes del pesaje Mantiene el valor del objeto pesado en el display hasta que se HOLD RELEASE presione el bot n otra vez para limpiar el valor Tambi n usado para moverse hacia abajo en el menu REWEIGH Permite repetidos pesajes del paciente sin salir de la balanza Bot n KG LB Alterna entre kilogramos o libras Tambi n usado para moverse hacia arriba en el menu WE O HHOOO OG MENU Entra al menu de la balanza BMI Solicita la entrada de datos para calcular el indice de Masa del Cuerpo Body Mass Index BMI del paciente Imprime los datos del paciente si la impresora
20. NCE Oo ion CO 35 LOCALISATION DES PANNES ane LE 36 MODE rr en RA CEA 37 SCHEMA DE LA BALANCE EN PIECES DETACHEES 37 LIS TE DE PI CES V 39 GARANTE uri Rn me 40 21 BALANCES COM PRECAUTION ET PREVENTION Pour pr venir toute blessure ou tout d gat accidentels veuillez scrupuleusement vous conformer aux instructions suivantes e Ne d placez pas la balance lectronique lorsque son plateau est charg e Pour obtenir une lecture du poids exacte placez la balance lectronique sur une surface plane et stable e Pour obtenir une lecture du poids exacte v rifiez le bon fonctionnement de la bascule en appliquant la proc dure d crite dans ce manuel avant chaque utilisation e Ne pas utiliser en pr sence de substances inflammables e Le fonctionnement sous d autres tensions et fr quences que celles sp cifi es dans ce manuel est susceptible d endommager l appareil e Si l indicateur LOW BAT est actif remplacez les piles ou connectez d s que possible la balance a une source d alimentation CA de fa on obtenir une lecture du poids exacte SPECIFICATIONS GENERALITES La balance clinique lectronique Pro Plus de Health o meter Mod le 2101KL utilise une technologie tr s sophistiqu e de microprocesse
21. ULE 1 4 3822601 0 PETIT COUVERCLE ARRIERE 1 5 3822901 0 POIGNEE 1 6 3822101 0 BARRE D APPUI 1 7 381 7001 0 SUPPORT DE L ADAPTATEUR 1 8 VIS A TOLE 8 1 2 11 9 FICHE SIGNALETIQUE HEALTH O METER 1 10 FICHE SIGNALETIQUE DU MODELE 1 11 VIS A TETE FRAISEE NC5 16 3 4 4 12 3822001 0 ENSEMBLE CHASSIS 1 13 2267201 0 ENSEMBLE CAOUTCHOUC 2 14 2138901 0 TABLEAU DE CONNEXION NUMERIQUE CON DIG 1 15 VIS A TETE PHIL PAN NC6 1 4 1 16 3822401 0 COUVERCLE INFERIEUR 1 17 2266701 0 ENSEMBLE PIEDS EN PLASTIQUE NC3 8 4 18 VIS A TETE FRAISEE NC5 16 18 3 4 8 19 1304202 0 CELLULE DE CHARGE 4 20 3823001 0 TAPIS PVC 1 21 VIS A TETE FRAISEE NC1 4 3 4 10 22 401305 AGRAFE DE FIXATION DU CABLE 4 23 BARRE D APPUI GAUCHE 1 24 BARRE D APPUI DROITE 1 25 3822501 0 COUVERCLE FRONTAL 1 26 VIS A TETE FRAISEE NC3 8 1 5 2 27 VIS A TETE PHIL PAN NC8 5 16 6 28 3822701 0 COUVERCLE ARRIERE 1 29 420988 ADAPTATAEUR 6VDC 120VAC 1 30 ATTACHE DE CABLE CV100 1 31 411192 PAVE NUMERIQUE 800LB 1 32 DESSUS DE LA TETE DE LECTURE 1 33 FENETRE LCD 1 34 TABLEAU LCD 1 35 VIS CRUCIFORME WN1412 K22L6 4 36 CABLE DE LA CARTE ECRAN EAGLE 1 37 VIS CRUCIFORME WN1412 K30L6 4 38 CARTE EAGLE 1 39 BASE DE LA TETE DE LECTURE 1 40 VIS A TETE PHIL PAN NC6 32 3 8 6 41 FICHE SIGNALETIQUE DU MODELE 1 42 3245801 0 SCHEMA DES PORTS D ENTREE SORTIE 1 43 VIS A TETE PHIL PAN NC4 40 1 4 1 44 3822801 0 COUVERCLE DU LOGEMENT DES PILES 1 45 400152 RONDELLE EN CAOUTCHOUC 1 46 2033
22. Volume 05 Disp Date 8 Time 06 Display Backlight 07 Display Contrast 8 Live Weight 09 Exit 01 Temps de Maintien Automatique L utilisateur peut d terminer la dur e d affichage du poids une fois que celui ci est d fini et ce que le patient reste ou non 00 sur la plateforme La dur e d finie par d faut est l absence Seconds de temps de maintien Le r glage maximum de cette option est de 20 secondes Enter L utilisateur peut r gler le temps a couler avant que la balance ne se mette en mode de veille Le r glage par d faut de cette option est de 1 minute Quand la balance se met en 1 00 veille la mention STANDBY en attente s affiche a l cran Enter 29 BALANCES COM MODE DE FONCTIONNEMENT 03 Arr t automatique 10 Minutes Enter 04 Puissance du son gt 02 Stable Weight 03 Alarm Tone v av to change Enter AY to change Enter L utilisateur peut d finir le temps d attente de la balance avant que celle ci ne s teigne automatiquement suite a son inutilisation prolong e Le temps r gl par d faut est de 10 minutes Le r glage de cette valeur sur z ro d sactive la fonction d arr t automatique Il existe une option permettant de r gler le bip de la balance Ce son se d clenche quand la bascule vient de d finir le poids de la personne ou de l objet se trouvant sur la plateforme quand une touche est appuy e lors de l allumage de l appareil la fin de l autotes
23. Weight DESCENDANT DES OPTIONS DU MENU SELON LA FLECHE 03 Data Management UTILISEE Exit L OPTION ACTIVE DU MENU EST INDIQUEE PAR INVERSION DE COULEUR 04 Scale Settings 05 System Settings 06 System Test 07 User Settings 08 Exit Figure 3 Menu Principal 01 MODE D AFFICHAGE DU POIDS ne s applique que pour les valeurs en livres et NON pour les valeurs m triques L utilisateur peut r gler la nature de la valeur affich e dans l une des fractions de la livre 74 72 or Ib en livres et onces r solution de 4 onces ou en d cimales r solution de 0 2 Ib Lorsque I unit de poids s lectionn e est le kg ces r glages ne prennent pas effet Le mode s lectionn est appliqu a tous les crans 01 14 2004 11 30pm 185i 01 14 2004 11 30pm 02 Pounds amp Ounces 1 85 41 ence Enter 01 14 2004 11 30pm 185 8 Figure 4 Mode d affichage du poids 26 BALANCES COM MODE DE FONCTIONNEMENT 02 POIDS DE LA TARE REMARQUE Etant donn le degr de sensibilit de la balance nous recommandons d utiliser la fonction de repes e REWEIGH avant de r gler le poids de la TARE afin d liminer toute interference ventuelle de l op rateur avec l objet a tarer Il existe deux mani res d introduire manuellement le poids de la tare par ex le poids d un fauteuil roulant de chaussures etc appuyez sur MENU 1 et s lectionnez l option 02 Tare Weight ou appuyez sur T
24. a inactividad El tiempo predeterminado es de 10 minutos Si 10 Minutes el valor es establecido como cero la funci n Apagar Autom tico es desactivada Enter 04 Volumen del Tono Existe una opci n para ajustar el tono del beep de la balanza Este tono sonara cuando la balanza haya gt determinado el peso en la plataforma cuando una tecla es 02 Stable Weight presionada despu s que la balanza es activada al final 03 Alarm Tone a de la auto prueba o en caso de falla o advertencia av to change Enter Use las teclas 4 y v en el teclado para ajustar el volumen Siempre que el usuario presiona la tecla para cambiar el volumen un beep sonar para indicar el ajuste del nivel del volumen AY to change Enter 05 Exhibir Fecha y Hora Esta opci n activar o desactivar el display de la fecha y hora No av to change Enter 01 14 2004 11 30pm ZERO ZERO 000 00 000 000 50 BALANCES COM INSTRUCCIONES DE OPERACION 06 Luz de Fondo del Display El usuario puede establecer el brillo de la luz de fondo AY to change Enter 07 Contraste del Display El usuario puede establecer el brillo del LCD AY to change Enter 08 Peso Vivo Al seleccionar Yes el usuario puede establecer el modo Peso Vivo para desactivar el modo Sensible a Movimientos En el modo Peso Vivo el peso presentado oscilara con los No movimientos del paciente la balanza no se traba rapidamente en el peso como en el cas
25. bration 5 Improper Tare N a Remove interfering object from the scale 2 Ask the patient to get off the scale zero the scale and begin weighing process again 3 Place the scale on a level floor and begin weighing process again 4 Check weight with known weight value 5 Place the item to be tared on the scale Press REWEIGH Once the weight of the item is displayed press TARE Place the patient and the tared item back on the scale Press REWEIGH again Weighing is performed but the display shows weigh and reweigh every few seconds the weighing process takes too long and no weight is displayed The patient is not standing still Ask the patient to stand still or you can change to live weight setting The display shows Overload message The load on the scale exceeds the capacity 800 Lbs Remove the excess weight and use the scale according to its limits The display shows The batteries are empty Replace batteries according to LOW BAT message instructions The display shows There is a problem with one Check load cell cable Load Cell Error message or more load cells or the load cell cable is disconnected connection at the display and platform assembly ports If the problem is not corrected refer to gualified service personnel to replace the defective load cell 16 BALANCES COM CALIBRATION PATH The calibration is performe
26. cale will display the estimated amount of battery life remaining until the batteries will have to be replaced NOTE In order to complete the battery test the scale must be powered by batteries only Unplug the scale from AC power source prior to battery test The scale will test the connection to the PC and will display a message Connection is OK or NO Connection If NO Connection is displayed check your USB connections on the scale and on your PC and retest the connection Refer to qualified service personnel if problem persists 12 BALANCES COM OPERATION INSTRUCTIONS 03 Ul Test Please Press Please press the button marked 1 you have 10 seconds Exit UI Error Failure 07 USER SETTINGS 01 Retain Entered Values Yes AY to change Enter The scale has a diagnostic routine where it tests the User Interface Ul hardware functionality LCD keypad In order to do this the user has to press all the keys according to the messages displayed on the screen If the requested command was not received or wrong button was pressed the following message will be displayed If after 10 seconds the requested command was not received the following message will be displayed If UI Error Failure is displayed refer to qualified service personnel 02 Disp Height amp ID 03 Prompt For Height v Exit 04 Prompt For ID 05 Exit This option allows the user to use the same
27. cts Inc Boca Raton FL 33431 ProPlus is est une marque d pos e de of Pelstar LLC En instance d octroi de brevet 40 BALANCES COM BALANZA CLINICA ELECTRONICA PRO PLUS MODELO 2101KL INDICE PRECAUCI N Y ADVERTENCIAU aees LL LL LL LL LL LL LL 42 5 0 0 0 1 enn a 42 CONFIGURACI N label 43 INSTRUCCIONES DE 10202 0 20 2 0122 101 1 0 44 VANESA SNO 55 SOLUCI N DE PROBLEMAS 56 TRAYECTORIA DE 0 0 00 006000 001 001 1010151 5722252 21022 5 80 57 VISTA DETALLADA DE 57 LISTA IDE PIEZAS 59 ej RI E OT 60 41 BALANCES COM PRECAUCION Y ADVERTENCIA Para evitar lesiones y da os a su balanza por favor siga estas instrucciones con mucho cuidado e No traslade la balanza mientras la plataforma est cargada e Para un pesaje exacto la balanza debe ser colocada en una superficie plana estable e Para un pesaje exacto verifique antes de cada uso la apropiada operaci n seg n los procedimientos descritos en este manual e No use en presencia de materiales inflamables e Operando en otros voltajes y frecuencias que los especificados puede hac
28. d using its AC adapter or by 6 D cell batteries not included SCALE SPECIFICATIONS Capacity and Resolution 800 Lb x 0 2 Lb 4 Ib 4 oz 360 Kg x 0 1 Kg Power Requirements Adapter 120VAC 6VDC 60Hz or 6 x D size batteries Environmental Operating temperatures 50 F to 95 F 10 C to 35 C Storage temperatures 30 F to 125 F 0 C to 50 C Humidity 85 Physical Dimensions Platform Platform with Handrail Length 24 61 cm Length 30 76 cm Width 25 65 5 cm Width 25 65 5 cm Height 2 5 cm Height 45 115 cm Weight 65 5Lb 29 7Kg BALANCES COM SET UP 1 Remove protective plastic film from keypad and display 2 Place batteries in the battery holder see Replacing Batteries 3 Plug the scale s AC adapter into the power source 4 Press the ON OFF button to turn the scale on The display will show Health o Meter Pro Plus and then 000LbOOoz 5 Place a weight not to exceed 800 Lb 360 Kg on the scale The display should read WEIGHING until the weight calculation is complete and the weight is displayed 6 Press the KG LB button to select the weight mode Lb Kg 7 _ Press the REWEIGH button the scale should perform the weighing process again 8 Remove the weight from the scale the scale will return to zero and the display will read ZERO on the left upper side of the screen along with OOOLb00oz 9 Disconnect the scale s
29. d using kg or Ib according to the units of measure used upon entering into the calibration path Operator Action Display 1 Press ON OFF button and immediately press and Calibration hold HOLD RELEASE button for 3 4 seconds Process 2 Press ENTER Enter load weight 600 0 3 Using 4 v keys and or the keypad set the Zero calibration calibration load to at least 200 Ibs for best results Please clear the scale and greater accuracy use a 600 Ib weight Press ENTER 4 Please clear the scale platform and press ENTER Zero calibration Please wait 5 Please wait without touching or shaking the scale Weight calibration until the zero calibration process is finished Put XXX X 6 Load the scale platform with the required weight Weight calibration and press ENTER Please wait 7 Please wait without touching or shaking the scale Calibration until the calibration process is finished factor X XXXXX 8 Press ENTER Calibration Please clear the scale 9 Please remove weight from the scale platform Rebooting Please wait 10 Please wait until the scale resumes normal Health O Meter operation Pro Plus EXPLODED VIEW OF SCALE 17 BALANCES COM EXPLODED VIEW OF SCALE continue Q 9 QQQQA Q 18 BALANCES COM PARTS LIST Key No Part No
30. de connexion Si le message NO Connection est visualis v rifiez vos connexions USB sur la balance et sur votre PC puis renouvelez le test Si le probl me persiste veuillez consulter un technicien qualifi 32 BALANCES COM MODE DE FONCTIONNEMENT 03 Test Ul La balance dispose d une routine de diagnostic ou elle teste la fonctionnalit du mat riel LCD clavier de l Interface de l Utilisateur Ul Pour mettre cette routine en marche 1 l utilisateur doit appuyer sur les touches indiqu es au fur et ES mesure par les divers messages affich s l cran Please Press Ce message s affiche si la commande requise n a pas t recue ou en cas d erreur de touche Please press the button marked 1 you have 10 seconds Exit Ce message s affiche si apr s 10 secondes la commande requise n a pas t transmise En cas d apparition du message UI Error Failure Echec d interface veuillez consulter un UI Error technicien qualifi Failure 07 REGLAGES UTILISATEUR 02 Disp Height amp ID 03 Prompt For Height v Exit 04 Prompt For ID 05 Exit 01 Retenue des Valeurs introduites Cette option permet l utilisateur de retrouver les m mes valeurs ID hauteur et TARE d une pes e l autre Si cette option est d sactiv e l utilisateur doit r introduire ces valeurs Yes chaque lecture Si les valeurs ne sont pas introduites seul le poids sera m moris
31. dor Peso cuestionable o la balanza no vuelve a cero 1 Objeto externo interfiriendo en la balanza 2 El display no mostr 0 0 antes del pesaje 3 La balanza no est colocada sobre una superficie estable 4 La balanza no est calibrada 5 Tara Impropia 1 Remueva de la balanza el objeto que est interfiriendo 2 Pida al paciente que baje de la balanza vuelva la balanza a cero y empiece el proceso de pesaje nuevamente 3 Coloque la balanza en una superficie estable y empiece el proceso de pesaje nuevamente 4 Confiera el peso con un valor de peso sabido 5 Coloque el item a ser considerado peso tara en la balanza Presione REWEIGH Una vez que el peso del tem es exhibido presione TARE Coloque el paciente y el item tara nuevamente en la balanza Presione REWEIGH otra vez El pesaje es ejecutado pero el display muestra weigh y reweigh a cada pocos segundos el proceso de pesaje es muy demorado y ning n peso es exhibido El paciente no est parado quieto Pida al paciente pararse quieto o cambie para la configuraci n peso vivo El display muestra el mensaje Overload La carga en la balanza excede su capacidad 800 Lbs Remueva el peso excesivo y use la balanza seg n sus limites El display muestra el mensaje LOW BAT Las bater as est n vac as Cambie las bater as seg n las instrucciones El display exhibe el mensaje Load
32. e follow these instructions very carefully e Do not transport the scale while the platform is loaded e For accurate weighing the scale must be placed on a flat stable surface e For accurate weighing verify proper operation according to the procedure described in this manual before each use e Do not use in the presence of flammable materials e Operating at other voltages and frequencies than specified could damage the equipment e lf the LOW BAT indicator activates for accurate weighing replace the batteries or connect the scale to an AC power source as soon as possible SPECIFICATIONS GENERAL Health o meter s Pro Plus Electronic Handrail Scale Model 2101KL uses highly sophisticated microprocessor technology Each precision instrument is designed to provide accurate reliable and repeatable weight measurements and features that make the weighing process simple fast and convenient The scale is set up to use motion sensing weighing technology to determine the actual weight of a moving patient The scale may be changed to measure live weight see page 11 for instructions on changing the scale setting The weight can be display in pounds decimals fractions of a Ib or Ib oz or in kilograms The scale features a wrap around handrail for patient comfort and safety and a 180 degree swivel pivot head for reading from either side of the scale Also included in the scale are two wheels for easy mobility The unit can be operate
33. e probl me persiste veuillez avoir recours au technicien qualifi a Pour r gler la luminosit de fond et ou le contraste de l cran cf page 31 Pour passer du mode d affichage en livres aux fractions ou d cimales cf page 26 oN ct m Remplacement des piles vis 43 COUVERCLE DU LOGEMENT DES PILES SS LOGEMENT DES PILES CONNECTEUR DE CABLE DU LOGEMENT DES PILES CONNECTEUR PILES BALANCE Figure 1 Replacement des piles Cf Liste des pieces page 39 pour plus de d tails sur les pieces suivies du symbole 1 D branchez la balance 2 Retirez le couvercle du logement des piles du bloc d affichage 3 D branchez le connecteur de cable du logement des piles du connecteur piles balance 4 Retirez le logement des piles avec pr cautions en le faisant glisser doucement hors du bloc d affichage 5 Remplacez les anciennes piles par les nouvelles 6 Replacez avec pr cautions le logement des piles dans le bloc d affichage 7 Branchez le connecteur de cable du logement des piles au connecteur piles balance 8 Fixez le couvercle du logement des piles au bloc d affichage et placez la vis Pour r gler l option par d faut de I unit de poids en kilogrammes ou pour d sactiver la touche LB KG veuillez contacter notre service d Assistance Technique au 1 800 638 3722 ou 1 708 598 9100 Nous recommandons l utilisation des piles EVEREADY Energizer e2 23 BALANCES COM MODE DE FON
34. ec barre d appui Longueur 24 61 cm Longueur 30 76 cm Largeur 25 65 5 cm Largeur 25 65 5 cm Hauteur 2 5 cm Hauteur 45 115 cm Poids 65 5Lb 29 7Kg BALANCES COM INSTALLATION Retirez le film protecteur en plastique du clavier et de l cran Placez les piles dans le logement pr vu a cet effet cf Remplacement des piles Branchez l adaptateur CA de la balance a la source d alimentation lectrique Appuyez sur la touche de Marche Arret ON OFF pour allumer l appareil L cran affiche le nom Health o Meter Pro Plus suivi de la mention 000Lb00oz Placez un poids ne d passant pas 800 Lb 360 Kg sur la bascule L cran de visualisation affiche la mention WEIGHING PESEE jusqu a l ex cution complete du calcul et l affichage du poids 6 Appuyez sur la touche KG LB pour s lectionner l unit de poids de votre choix 1 9 7 Appuyez sur la touche REWEIGH REPESEE pour renouveler le processus de pes e 8 Retirez l objet du plateau la balance se remet alors z ro et l cran affiche la mention ZERO sur le c t sup rieur droit accompagn e de 000150002 9 D connectez la balance et son adaptateur CA du secteur lectrique La balance s teint Appuyez nouveau sur la touche ON OFF et la balance basculera sur piles REMARQUE Si la proc dure d installation a chou consultez la fiche de localisation des pannes Si l
35. efecto de fabricaci n o mano de obra el remedio nico ser la reparaci n o reemplazo de la balanza sin cargo alguno para el cliente El reemplazo se realizar con un equipo o componente nuevo o remanufacturado Si el producto se encontrase fuera de producci n se le remplazar con un producto similar del mismo o mayor valor Todas las partes incluyendo las partes separadas o remplazadas est n cubiertas nicamente durante el periodo original de la garant a Qui n Est Cubierto El comprador original del producto debe poder comprobar la compra para hacer v lida la garant a Los distribuidores o minoristas de Pelstar no tienen derechos para alterar modificar o cambiar de ninguna manera los t rminos y condiciones de esta garant a Qui n Est Excluido La garant a no cubre el desgaste normal de las partes o da os como resultado de Uso negligente o mal uso del equipo uso de voltajes o corrientes inapropiadas utilizaci n contraria a las instrucciones de operaci n abuso incluyendo modificaciones da os en transporte reparaciones o alteraciones no autorizadas M s a n la garant a no cubre sucesos naturales como fuego inundaciones huracanes o tornados Esta garant a le da a Ud derechos legales espec ficos puede tener adem s otros derechos que var an de pa s a pa s estado a estado provincia a provincia o jurisdicci n a jurisdicci n Para obtener Servicio de Garant a Aseg rese de conservar su recibo de venta
36. ental Temperaturas de Operaci n 50 F hasta 95 F 10 C hasta 35 C Temperaturas de Almacenamiento 30 F hasta 125 F 0 C hasta 50 C Humedad 85 Dimensiones Fisicas Plataforma Plataforma con Barra de Apoyo Largo 24 61 cm Largo 30 76 cm Ancho 25 65 5 cm Ancho 25 65 5 cm Altura 2 5 cm Altura 45 115 cm Peso 65 5Lb 29 7Kg BALANCES COM CONFIGURACION Quite la pelicula plastica protectora del teclado y del display Coloque las bater as en el soporte de las bater as ver Cambiando las Bater as Enchufe el adaptador CA de la balanza en la fuente de energ a Presione el bot n ON OFF para activar la balanza El display muestra Health o Meter Pro Plus y despu s 000Lb000z Ponga un peso no superior a 800 Lb 360 Kg en la balanza El display deber mostrar WEIGHING hasta que el c lculo del peso sea completado y el peso exhibido Presione el bot n LBS KG para seleccionar el modo de peso Lb Kg Presione el bot n REWEIGH la balanza deber realizar el proceso de peso nuevamente Retire el peso de la balanza la balanza vuelve a cero y el display exhibe ZERO en el lado superior izquierdo de la pantalla juntamente con 0001500 2 9 Desconecte el adaptador CA de la balanza de la fuente de energ a La balanza se apaga Presione ON OFF y la balanza pasa a energ a por bater a mo R m NOTA Si el procedi
37. er da o al equipo e Sielindicador de LO BAT se activa para un pesaje exacto cambie las bater as o conecte la balanza a una fuente de energ a CA lo m s pronto posible ESPECIFICACIONES GENERAL La Balanza Cl nica Electr nica Pro Plus Modelo 2101KL de Health o meter usa tecnolog a de microprocesador altamente sofisticada Cada instrumento de precisi n es proyectado para proveer medidas de peso exactas confiables repetibles y caracter sticas que hacen el proceso de pesaje simple r pido y conveniente La balanza est configurada para usar tecnolog a de pesaje sensible a movimientos para determinar el peso de un paciente en movimiento La balanza puede ser cambiada para medir peso vivo ver p gina 51 para instrucciones de c mo cambiar la configuraci n de la balanza El peso puede ser presentado en libras decimales fracciones de una libra o en libras onzas o en kilogramos La balanza tiene una barandilla envuelta para comodidad y seguridad del paciente y un eslab n giratorio cabeza giratoria de 180 grados para leer de cualquier lado de la balanza La balanza incluye tambi n dos ruedas para f cil movilidad La unidad puede ser operada usando su adaptador de energ a CA o por medio 6 D bater as no incluidas ESPECIFICACIONES DE LA BALANZA Capacidad y Resoluci n 800 Lb x 0 2 Lb 4 Ib 4 oz 360 Kg x 0 1 Kg Requerimientos de Energia Adaptador 120VAC 6VDC 60Hz o 6 x baterias tama o D Ambi
38. esta conectada PRINT a la balanza Solicita la entrada del numero de identificaci n del paciente ID ID Este ID identificaci n ser almacenado con todos los pesajes realizados hasta que sea borrado o que un distinto ID sea almacenado Solicita la entrada del valor TARA que ser deducido del peso TARE en la plataforma Tambi n libera el peso tara vuelve el display a cero Vuelve un paso atr s cuando en los modos del menu o de EXIT entrada de datos ENTER Usado para entrar comandos y valores en la balanza 45 BALANCES COM MENU En la pantalla del menu el usuario puede establecer preferencias y o instruir la balanza como manejar datos almacenados Puede se navegar por el menu usando se las teclas 4 v para arriba o para abajo o introduciendo el n mero del men asociado al teclado El men tiene una manera de trabajar roll over cuando el usuario va hasta el final del men y presiona la tecla para abajo vuelve se al inicio del men INDICADOR DE LA POSICION EN EL MENU MUEVASE PARA ARRIBA 02 Tare Weight Y PARA ABAJO USANDO 03 Data Management LAS TECLAS A Y v v Exit 04 Scale Settings 05 System Settings 06 System Test 07 User Settings 08 Exit LA OPCION ACTIVA DEL MENU ESTA MARCADA EN COLOR INVERTIDA Figura 3 Menu Principal 01 MODO DE PRESENTACI N DEL PESO aplicable solamente a valores en libras NO a valores m tricos El usuario puede establecer el valor de display e
39. forme de la balance et appuyez Zero calibration Calibrage Z ro sur ENTER Veuillez patienter 5 Veuillez patienter sans toucher ni faire bouger la Weight calibration balance jusqu ce que le processus de mise Calibrage du poids z ro du calibrage soit termin Mettez XXX X 6 Chargez la plateforme de la balance avec le Weight calibration poids requis et appuyez sur ENTER Calibrage du poids Veuillez patienter 7 Veuillez patienter sans toucher ni faire bouger la Calibration Calibrage balance jusqu ce que le processus de mise Facteur X XXXXX z ro du calibrage soit termin 8 Appuyez sur ENTER Calibration Calibrage Veuillez lib rer la balance 9 Retirez le poids de la plateforme de la balance Rebooting R amorcage Veuillez patienter 10 Veuillez patienter jusqu ce que la balance Health O Meter recouvre son fonctionnement normal Pro Plus SCHEMA DE LA BALANCE CLINIQUE ELECTRONIQUE EN PIECES DETACHEES 37 BALANCES COM SCHEMA DE LA BALANCE CLINIQUE ELECTRONIQUE EN PIECES DETACHEES suite 2 y BALANCES COM LISTE DES PIECES Pi ce N Code Description Quantit 1 1109401 0 BLOC D AFFICHAGE 1 2 2033701 0 TABLEAU DE CONTROLE CABLE DE LA BOITE DE 1 DERIVATION 3 2266901 0 MECANISME DE BASC
40. gal rights and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jurisdiction To get Warranty Service Make sure you keep your sales receipt or document showing proof of purchase Call 1 800 638 3722 or 1 708 598 9100 to receive a return authorization number Attach proof of purchase to your defective product along with your name address daytime telephone number and description of the problem Carefully package the product and send with shipping and insurance prepaid to Pelstar LLC Attention R A Repair Department 7400 W 100th Place Bridgeview IL 60455 If your scale is not covered by warranty or has been damaged an estimate of repair costs or replacement costs will be provided to you for approval prior to servicing or replacing Pelstar LLC 7400 West 100th Place Bridgeview IL 60455 1 800 638 3722 or 1 708 598 9100 www healthometermedical com Health o meter ProPlus products are manufactured designed and owned by Pelstar LLC Health o meter is a registered trademark of Sunbeam Products Inc Boca Raton FL 33431 ProPlus is a trademark of Pelstar LLC Patents Pending 20 BALANCES COM BALANCE CLINIQUE ELECTRONIQUE PRO PLUS MODELE 2101KL TABLE DES MATIERES PRECAUTION E T PREVENTION ada 22 SPECIFICA MONS 5 Gi a AR 22 INSTALLATION sonic 23 MODE DE FONCTIONNEMENT 2 ideo anne 24 MAINTENA
41. ge Enter 07 Display Contrast The user can set the brightness of the LCD AY to change Enter 08 Live Weight By selecting Yes the user can set the Live Weight mode to deactivate the motion sensing mode In the Live Weight mode the weight displayed will fluctuate with the patient s No movement the scale will not lock on quickly to the weight as is the case in the motion sensing mode AYto change Enter Press the REWEIGH button to operate the motion sensing mode and to determine the correct weight on the screen To revert back to motion sensing mode change the Live Weight setting to No 05 SYSTEM SETTINGS gt 02 About v AY to change Enter 01 Set Time Date The user can set the time and date using the keypad To set the time move between hours minutes and seconds 04 32 01 using the up and down keys 4 v and enter the values on the UE keypad To jump to the AM PM line press the ENTER button AM PM once AY to change Enter 11 BALANCES COM OPERATION INSTRUCTIONS 10 05 03 Avtochange Enter 02 About uPSD 10625 PIC Ver 10623 LoadCell 10622 Last Update 01 15 04 Exit Enter 06 SYSTEM TEST 01 Battery Test 02 USB Connection Connection is OK Set the date using the up and down keys 4 v and enter the values on the keypad This screen displays the software version of the scale 2 02 USB Connection 03 UI Test v AY to change Enter The s
42. gt 02 Store In memory 03 Do not store data v AY to change Enter T l chargement Automatique Le t l chargement automatique est l option par d faut il transf re la valeur au PC d s que le patient descend de la balance ou quand l utilisateur appuie sur la touche Updated HOLD RELEASE Maintien Lib ration si celle ci tait en position HOLD En l absence de connexion PC la valeur n est ni transf r e ni stock e et sera perdue apr s avoir fait descendre le patient de la balance 2 M morisation La valeur est m moris e pour t l chargement ult rieur au PC Si la m moire est presque Updated pleine l utilisateur en sera averti et l option de transfert 02 Clear memory de toutes les valeurs au PC Exit ou de lib ration de la m moire lui sera propos e o 3 Non m morisation Toutes les donn es seront annul es Updated 28 BALANCES COM MODE DE FONCTIONNEMENT 04 Transfert imm diat Toutes les valeurs m moris es sont transf r es au PC et la m moire de la balance est ainsi compl tement d gag e Si le transfert choue les valeurs sont maintenues en m moire jusqu au succ s du transfert ou jusqu l ordre d effacement 05 Effacement des donn es en m moire Toutes les valeurs stock es en m moire sont effac es No AY to change Enter 04 REGLAGES DE LA BALANCE gt 02 Sleep Time 03 Auto Off Time v av to change Enter 04 Tone
43. ions de maintenance autres que celles d crites dans ce chapitre doivent tre ex cut es par un technicien gualifi MAINTENANCE Avant la premi re utilisation et apr s de longues p riodes d inutilisation v rifiez le bon tat de marche de la bascule Si la balance ne fonctionne pas correctement veuillez vous adresser a un technicien qualifi 1 V rifiez l aspect g n ral de la balance pour y d tecter tous ventuels d g t ou usure apparents 2 _ V rifiez que l adaptateur CA ne pr sente aucun craquellement ni usure de son cable pas plus que de broches bris es ou tordues NETTOYAGE Des soins et un entretien corrects sont essentiels pour assurer une longue dur e de vie a la balance avec fonctionnement pr cis et efficace D connectez la balance du secteur CA 1 Nettoyez toutes les surfaces externes avec un chiffon doux et humide est possible d utiliser un savon doux et une solution aqueuse S chez avec un chiffon doux et propre 2 Ne trempez pas la balance dans une solution de nettoyage ni autre substance 3 N utilisez pas d alcool isopropylique pour nettoyez l cran 35 BALANCES COM LOCALISATION DES PANNES Reportez vous aux instructions suivantes pour v rifier et rectifier une panne avant de contacter un technicien qualifi SYMPTOME CAUSE POSSIBLE ACTION CORRECTIVE La balance ne s allume pas Les piles sont mortes 2 Prise lectrique d fectueuse 3 Mauvaise alime
44. la balance BMI Guide la saisie de donn es pour calculer l Indice de Masse Corporelle IMC du patient BMI Body Mass Index PRINT Imprime les donn es relatives au patient a condition que l imprimante soir reli e a la balance Guide la saisie du num ro d identification du patient ID Ce ID num ro ID sera enregistr avec toutes les pes es effectu es et ce jusqu l effacement ou l enregistrement d un autre num ro ID Guide la saisie de la valeur de la TARE qui sera d duite du poids amp TARE sur la plateforme Cette m me touche sert annuler le poids de la tare remet l affichage z ro EXIT Revient un pas en arri re si l on se trouve dans le menu et modes de saisie de donn es ENTER Sert valider les commandes et introduire les donn es dans la bascule 25 BALANCES COM MODE DE FONCTIONNEMENT MENU Sur l cran du menu l utilisateur peut r gler ses pr f rences et ou d terminer le mode de traitement des donn es enregistr es appliquer par la balance peut feuilleter le menu par le biais des touches indiquant les fl ches ascendante et descendante v ou en tapant l aide du clavier le num ro de position du menu correspondant Le menu dispose d un mode d op ration par tamponnement une pression sur la fl che descendante lorsque le menu t d roul jusqu au bout ram nera celui ci son d but INDICATEUR DE POSITION DU MENU DEFILEMENT ASCENDANT OU 02 Tare
45. miento de configuraci n falla dirijase a las instrucciones de soluci n de problemas Si el problema no es corregido refi rase al personal de servicio calificado Para ajustar la luz de fondo y o el contraste por favor refi rase a la p gina 51 Para cambiar el modo de presentaci n en libras para fracciones o decimales por favor refiera se a la p gina 46 Cambiando las Bater as TORNILLO TAPA DE LA BATERIA SOPORTE DE LA BATERIA CONECTOR DE LA BATERIA DE LA BALANZA CABLE CONECTOR DEL SOPORTE DE LA BATERIA Figura 1 Cambiando las Bater as refi rase a la Lista de Piezas en la p gina 59 para detalles sobre piezas seguidas de GH 1 Desconecte la balanza de la fuente de energ a Saque la tapa de la bateria de la unidad de display Desconecte el cable conector del soporte de la bateria del conector de la bateria de la balanza Con cuidado saque el soporte de las baterias de la unidad de display Substituya las baterias por nuevas Con cuidado posiciones el soporte de las baterias en la unidad de display Enchufe el cable conector del soporte de la bateria al conector de la bateria de la balanza Una la tapa de la bateria a la unidad de display e instale el tornillo 9 To NOR Para cambiar las unidades predeterminadas de la balanza a kilogramos o para desactivar el bot n LB KG contacte por favor nuestra Ayuda T cnica a 1 800 638 3722 o 1 708 598 9100 Recomendamos el uso de baterias EVEREA
46. n TARE disparaitra de l cran et la balance reprendra son fonctionnement normal 03 GESTION DES DONNEES La balance g re les donn es du patient y compris son num ro d identification ID son poids sa hauteur la tare qui lui est attribu e et son IMC La valeur est m moris e ou transf r e au PC Cette fonction s effectue en ouvrant un nouveau fichier de donn es OUVERTURE D UN NOUVEAU FICHIER DE DONNEES 1 Appuyez sur la touche ID 7 2 Tapez le num ro d identification sur le clavier 3 Appuyez sur ENTER 27 BALANCES COM MODE DE FONCTIONNEMENT Cette bascule calcule galement l Indice de Masse Corporelle IMC BMI Body Mass Index CALCUL de l IMC 1 Installez le patient sur la plateforme de la balance 2 Appuyez sur la touche IMC BMI 2 3 Suivez les instructions donn es l cran pour introduire la hauteur du patient l aide du clavier suivant des carts de 1 4 1271 4 2 1 2 3 3 4 ou de 1 cm appliguez les pouces inches pour un poids donn en Ib et les cm pour les kg Appuyez sur ENTER pour valider 4 L indice IMC du patient apparait alors l cran La balance offre deux options pour g rer votre information transf rer t l charger les valeurs ou les stocker La premi re option t l charge transf re automatiquement la valeur sur votre ordinateur personnel La seconde option met la valeur en m moire La capacit maximale de la balance est de 270 fichiers diff rents
47. n borrados Updated 48 BALANCES COM INSTRUCCIONES DE OPERACION 04 Transferir ahora Todos los valores almacenados en la memoria son transferidos al PC y la memoria de la balanza esta limpia de todos los valores Si la transferencia no tuvo xito los valores son guardados en la memoria hasta una transferencia exitosa o hasta que sean borrados 05 Limpiar la memoria Todos los valores almacenados en la memoria ser n borrados No AY to change Enter 04 CONFIGURACIONES DE LA BALANZA gt 02 Sleep Time 03 Auto Off Time wv av to change Enter 04 Tone Volume 05 Disp Date 8 Time 06 Display Backlight 07 Display Contrast 8 Live Weight 09 Exit 01 Tiempo de Espera Automatico El usuario puede determinar cuanto tiempo durara el display del peso una vez determinado independiente si el paciente permanece en la plataforma El valor predeterminado de la 00 seconds balanza es sin Tiempo de Espera Automatico La configuraci n maxima de Tiempo de Espera es de 20 Enter segundos 02 Tiempo Inactivo El usuario puede determinar el tiempo transcurrido antes de la balanza pasar al modo inactivo El valor predeterminado es de 1 minuto Cuando la balanza pasa al modo inactivo 1 00 aparece STANDBY en la pantalla Enter 49 BALANCES COM INSTRUCCIONES DE OPERACION 03 Apagar Autom tico El usuario puede determinar cuanto tiempo la balanza operar antes de autom ticamente apagarse debido
48. n la pantalla en fracciones de libra 74 2 o lb en libras y onzas resoluci n de 4 onzas o en decimales resoluci n de 0 2 Ib Cuando el kilogramo kg es seleccionado como unidad de uso estas configuraciones no tienen ning n efecto El modo seleccionado es usado en todas las pantallas 01 14 2004 11 30pm 185941 01 14 2004 11 30pm 02 Pounds amp Ounces 1 85 51 snl Enter 01 14 2004 11 30pm 185 8 Figura 4 Modo de Presentaci n del Peso 46 BALANCES COM INSTRUCCIONES DE OPERACION 02 PESO TARA NOTA Debido a la sensibilidad de la balanza recomendamos usar la funci n REWEIGH antes de establecer el peso TARA a fin de eliminar cualquier interferencia del operador en el item a tener el peso disminuido Existen dos maneras de introducir manualmente un peso tara asi como el peso de una silla de ruedas zapatos etc presione MENU 1 y elija la opci n 02 Tare Weight o presione TARE 9 Si no hay ningun peso en la plataforma de la balanza el valor exhibido es cero y no hay tara y el usuario presiona el bot n TARE 9 aparece la ventana del Peso Tara y solicita al usuario que de entrada del valor TARA y a presionar ENTER NOTA El peso tara debe ser introducido usandose los siguientes incrementos 4oz 0 2lb 74 Ib El valor introducido sera exhibido en menos Despu s de introducido el valor TARA la balanza vuelve a operaci n normal Este valor TARA es almacenado en la memoria hasta que sea
49. nt compte de ses limites L cran affiche le message LOW BAT Les piles sont faibles Remplacez les piles suivant les instructions L cran affiche le message Load Cell Error erreur de cellule de charge Il y a un probl me dans l une ou plusieurs des cellules de charge ou bien le c ble de la cellule de charge est d connect V rifiez le branchement du c ble de la cellule de charge aux ports du bloc d affichage et de la plateforme Si cela ne suffit pas r gler le probl me veuillez vous adresser un technicien qualifi pour remplacer la cellule de charge d fectueuse 36 BALANCES COM MODE DE CALIBRAGE Le calibrage s effectue en mode kg ou Ib selon les unit s de mesure utilis es au d but de l op ration de calibrage Action r alis e par l op rateur Message affich 1 Appuyez sur la touche de Marche Arr t et Calibration Calibrage ensuite imm diatement sur la touche Processus HOLD RELEASE en la maintenant appuy e pendant 3 4 secondes 2 Appuyez sur ENTER Enter load weight Introduisez le poids de la charge 600 0 3 A l aide des touches v et ou du clavier r glez Zero calibration Calibrage Z ro la charge de calibrage une valeur d au moins Veuillez lib rer la balance 200 Ibs pour de meilleurs r sultats et une plus grande pr cision utilisez un poids de 600 Ib Appuyez sur ENTER 4 Lib rez la plate
50. ntation 1 Remplacez les piles 2 Utilisez une autre prise 3 Remplacez l adaptateur Le poids affich est contestable ou la balance ne se met pas z ro 1 corps tranger et en contact avec la balance 2 L affichage n indique pas la mention 0 0 avant d effectuer la pes e 3 18 balance n est pas plac e sur sol plat 4 La bascule n est pas calibr e 5 Tare incorrecte 1 Eloignez le corps tranger de la balance 2 Demandez au patient de descendre de la balance mettez la ensuite a z ro et renouvelez la pes e 3 Placez la bascule sur sol plat et recommencez le processus de pes e 4 Faites les verifications l aide d un objet dont le poids est connu 5 Placez l objet tarer sur la balance Appuyez sur REWEIGH Quand le poids de l objet s affiche appuyez sur TARE R installez le patient et l objet tar sur la balance Appuyez nouveau sur REWEIGH La pes e s effectue mais l cran affiche les mentions weigh et reweigh pes e et repes e toutes les quelques secondes le processus de pes e est trop long et aucun poids ne s affiche Le patient n est pas immobile Demandez au patient de ne pas bouger ou bien r glez l appareil sur l option Poids Vif L cran affiche un message de surcharge Overload La charge sur la bascule d passe la capacit de l appareil 800 Lbs Retirez tout objet superflu et utilisez la balance en tena
51. o aparte de las descritas en esta secci n deben ser realizadas por el personal de servicio calificado MANTENIMIENTO Antes de usarla por primera vez y despu s de periodos sin usarla confiera la balanza para una operaci n y funci n apropiadas Si la balanza no operar correctamente refiera se al personal de servicio calificado 1 Verifique el aspecto total de la balanza para saber si hay cualquier da o desgaste obvios 2 Inspeccione el adaptador de CA para verificar Gord n con grietas o corroido o para dientes quebrados o acodados LIMPIEZA Cuidado apropiado y limpieza son esenciales para asegurar una vida de operaci n larga exacta y eficaz Desconecte la balanza de la fuente de energia CA 1 Limpie todas las superficies externas con un pafio humedo limpio o con tisu Una soluci n suave de jab n y agua puede ser usada Seque con un pa o suave limpio 2 No sumerja la balanza en soluciones de limpieza u otro liquido 3 No use Alcohol Isopropilo u otras soluciones para limpiar la superficie del display 55 BALANCES COM SOLUCION DE PROBLEMAS Refiera se a las siguientes instrucciones para verificar y corregir cualquier falla antes de contactar el personal de senrvicio SINTOMA POSIBLE CAUSA ACCI N CORRECTIVA La balanza no se prende 1 Bateria terminada Toma de corriente defectuosa Mala fuente de energia Cambie las bater as 2 Useuna toma de corriente distinta 3 Cambie el adapta
52. o del modo de AYto change Enter sensibilidad a movimiento Presione el bot n REWEIGH para operar el modo Sensible a Movimientos y determinar el peso exacto en la pantalla Para retornar al modo Sensible a Movimientos cambie la configuraci n de Peso Vivo a No 05 CONFIGURACIONES DEL SISTEMA gt 02 About v AY to change Enter 01 Fijar Hora y Fecha El usuario puede fijar la hora y la fecha usando el teclado Para fijar la hora mu vase entre horas minutos e segundos 04 32 01 usando las teclas para arriba y para abajo 4 v e introduzca ES los valores en el teclado Para saltar a la l nea AM PM AM PM presione el bot n ENTER una vez AY to change Enter 51 BALANCES COM Fije la fecha usando las teclas para arriba y para abajo Av e introduzca los valores en el teclado 10 05 03 AY to change Enter 02 Sobre uPSD 10625 Esta pantalla muestra la version del software de la balanza PIC Ver 10623 LoadCell 10622 Last Update 01 15 04 Exit Enter 06 PRUEBA DEL SISTEMA gt 02 USB Connection 03 UI Test v AY to change Enter 01 Prueba de la Bateria La balanza presentara la estimada cantidad restante de vida de la bateria hasta que las baterias tengan que ser reemplazadas NOTA Con la finalidad de completar la prueba de la bateria la balanza debe ser activada solamente por baterias Desconecte la balanza de la fuente de energia CA antes de la prueba de la bateria
53. ose described in this section should be performed by qualified service personnel MAINTENANCE Before first use and after periods of non use check the scale for proper operation and function If the scale does not operate correctly refer to qualified service personnel 1 Check overall appearance of the total scale for any obvious damage wear and tear 2 Inspect AC adapter for cord cracking or fraying or for broken or bent prongs CLEANING Proper care and cleaning is essential to ensure a long life of accurate and effective operation Disconnect the scale from the AC power source 1 Clean all external surfaces with a clean damp cloth or tissue Mild soap and water solution may be used Dry with a clean soft cloth 2 Do not immerse the scale into cleaning or other liquid solution 3 Do not use Isopropyl Alcohol or other solutions to clean the display surface 15 BALANCES COM TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on Dead Battery Faulty electrical outlet Bad power supply Replace batteries Use a different outlet Replace adapter Questionable weight or the scale does not zero N External object interfering with the scale 2 The display did not show 0 0 before weighing 3 Scale is not placed ona level floor 4 Scale is out of cali
54. pendant le transport les r parations alternance sans autorisation De plus la garantie ne couvre pas les catastrophes naturelles comme l incendie l inondation l ouragan et la tornade Cette garantie vous donne des droits l gitimes sp cifiques Le client peut galement b n ficier de certains autres droits qui varient selon les pays les tats les provinces ou les juridictions Pour obtenir un service de garantie Assurez vous d avoir conserv votre recu ou tout autre document prouvant votre achat Appelez le 1 800 815 6615 ou le 1 708 598 9100 pour recevoir un num ro d autorisation de renvoi Joignez votre preuve d achat au produit d fectueux en indiquant vos nom adresse num ro de t l phone dans la journ e et en donnant une description du probl me Emballez soigneusement le produit et envoyez le avec port et assurance pay s d avance Pelstar LLC Attention R A Repair Department 7400 W 100th Place Bridgeview IL 60455 Si votre p se personne n est pas couvert par la garantie ou a t endommag une estimation des frais de r paration ou de remplacement sera soumise a votre approbation avant l ex cution de la r paration ou du remplacement Pelstar LLC 7400 West 100th Place Bridgeview IL 60455 1 800 638 3722 or 1 708 598 9100 www healthometermedical com Les produits Health o meter sont fabriqu s congus et la propri t de Pelstar LLC Health o meter est une marque d pos e de of Sunbeam Produ
55. ranty Cover Pelstar LLC scales are warranted from date of purchase against defects of materials or in workmanship for a period of one 1 year If product fails to function properly return the product freight prepaid and properly packed to Pelstar See To Get Warranty Service below for instructions If manufacturer determines that a defect of material or in workmanship exists customers sole remedy will be repair or replacement of scale at no charge Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value All parts including repaired and replaced parts are covered only for the original warranty period Who is Covered The original purchaser of the product must have proof of purchase to receive warranty service Pelstar dealers or retail stores selling Pelstar products do not have the right to alter or modify or any way change the terms and conditions of this warranty What is Excluded Your warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instruction abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes This warranty gives you specific le
56. t ou en cas d erreur ou d avertissement Utilisez les touches 4 et v du clavier pour r gler la puissance du son Chaque fois que l utilisateur appuie sur une touche pour modifier le volume un bip retentit pour indiquer la puissance du son r gl e 05 Affichage de la Date et de l Heure AY to change 01 14 2004 11 30pm ZERO 00000 Cette option permet d activer ou de d sactiver l affichage de la date et de N O l heure Enter ZERO 000 000 30 BALANCES COM MODE DE FONCTIONNEMENT 06 Luminosit de fond de l affichage L utilisateur peut r gler la luminosit du r tro clairage A Y to change 07 Contraste L utilisateur peut r gler la luminosit de l affichage cristaux liquides LCD AY to change 08 Poids Vif En appuyant sur Yes Oui l utilisateur s lectionne le mode Poids Vif et d sactive le mode de lecture du poids par sensibilit au mouvement En mode Poids Vif le poids affich variera avec les mouvements du patient la balance n appliquera pas le blocage rapide pour fixer la lecture du AY to change poids comme elle le fait en mode sensible au mouvement Appuyez sur la touche REWEIGH Repes e pour activer le mode de sensibilit au mouvement et d terminer ainsi la lecture correcte du poids l cran Pour revenir au mode sensible au mouvement d s lectionnez le Poids Vif en appuyant sur l option No Non 05 REGLAGES DU SYSTEME gt 02 About
57. t remains on the platform The scale defaults to no Auto Hold Time The maximum setting is 20 seconds Hold Time 00 Seconds Enter 02 Sleep Time The user can set the time elapsed before the scale goes into the sleep mode The default is 1 minute When the scale goes into sleep mode STANDBY is displayed on the screen 1 00 Enter BALANCES COM OPERATION INSTRUCTIONS 03 Auto Off Time The user can determine how long the scale will operate before turning off automatically due to inactivity Default time is 10 minutes If the value is set to zero the auto off 10 Minutes function is disabled Enter 04 Tone Volume There is an option to adjust the beeping tone of the scale This tone should sound when the scale has determined gt the weight on the platform when a key is pressed after 02 Stable Weight the scale is turned on at the end of self test or in the case 03 Alarm Tone of fault or warning av to change Enter Use the 4 and v keys on the keypad to adjust the volume Whenever the user presses the key to change a volume a beep will sound to indicate the set volume level AY to change Enter 05 Display Date and Time This option will turn on or turn off the date and time display No AY to change Enter 01 14 2004 11 30pm ZERO ZERO 000 00 000 00 10 BALANCES COM OPERATION INSTRUCTIONS 06 Display Backlight The user can set the brightness of the backlight A Y to chan
58. ta v AY to change Enter 04 Transfer now 05 Clear memory 01 Auto Download Automatic Download is the default option and will transfer the value to the PC as soon as the patient steps off the scale or when the user presses the HOLD RELEASE button if it was Updated kept in HOLD If no PC is connected the value is not transferred and not stored and will be lost after the load is removed from the scale 02 Store in memory The value is stored in memory for later download to PC If the memory is close to full Updated the user will be warned and given the option to transfer all 02 Clear memory values to the PC or to clear Exit the memory of all values 03 Do not store data All the data will be cleared Updated BALANCES COM OPERATION INSTRUCTIONS 04 Transfer now All the values stored in memory are transferred to the PC and the scale memory is cleared of all values If the transfer was unsuccessful the values are kept in memory until successfully transferred or cleared 05 Clear memory All the values stored in memory will be cleared No AY to change Enter 04 SCALE SETTINGS gt 02 Sleep Time 03 Auto Off Time v av to change Enter 04 Tone Volume 05 Disp Date 8 Time 06 Display Backlight 07 Display Contrast 08 Live Weight 09 Exit 01 Auto Hold Time The user can determine how long to display the weight reading once it is determined regardless of whether the patien
59. to turn the scale on Wait until 000Lb000z and ZERO on the left side of the display appear Ask the patient to step on the scale The display should read WEIGHING until the weight of the person is displayed If you wish to reweigh without asking the patient to step off and to step on the scale again press the REWEIGH button Ask the patient to step off the scale NOTE The scale will always default to the settings and units last used BALANCES COM OPERATION INSTRUCTIONS a de do 2 1 SE Capacity 800 Ib x 2 Ib 363 kg x 100g Figure 2 Keypad ITEM DESCRIPTION FUNCTION POWER Turns scale ON and OFF ZERO Zeros the scale prior to weighing Holds the value of the weighed object on the display until HOLD RELEASE the button is pressed again to clear the value Also used to scroll down in the menu REWEIGH Allows repeated weighing of the patient without stepping off the scale KG LB button Toggles between kilograms or pounds Also used to scroll up in the menu 006 0 CEE amp DE MENU Enters the menu of the scale Prompts entry of data to calculate the patient s Body Mass BMI Index BMI PRINT Prints patient s data if printer is connected to the scale Prompts entry of patient s identification number ID This ID ID will be stored with all the weighing made until is cleared or a different ID is stored Prompts entry of TARE value that will be deducted
60. ur Chaque instrument de pr cision est concu pour donner la mesure exacte fiable et r p table du poids et pr sente des caract ristiques qui font de la pes e un processus simple rapide et pratique Cette balance est r gl e pour mesurer le poids par l application d une technologie de pes e sp ciale sensible au mouvement qui permet de d terminer le poids d un patient qui n est pas immobile Mais elle peut aussi tre r gl e pour mesurer le poids vif cf page 31 pour suivre les instructions de modification du r glage Le poids peut tre lu en livres nombres d cimaux fractions de Ib ou Ib oz ou en kilogrammes La balance est quip e d une barre d appui recouverte pour assurer le confort et la s curit du patient ainsi que d une t te de lecture sur pivot tournant 180 degr s et permettant de lire le poids de n importe quel c t de l appareil Deux roues sont galement fournies pour accroitre la mobilit de l appareil La balance peut tre utilis e avec son adaptateur lectrique CA ou avec 6 piles D non incluses SPECIFICATIONS DE LA BALANCE CLINIQUE ELECTRONIQUE Capacit et R solution 800 Lb x 0 2 Lb 4 Ib 4 oz 360 Kg x 0 1 Kg Exigences lectriques Adaptateur 120VAC 6VDC 60Hz ou 6 piles D Environnement Temp ratures de fonctionnement 50 F a 95 F 10 C a 35 C Temp ratures de stockage 30 F a 125 F 0 C a 50 C Humidit 85 Dimensions Plateforme Plateforme av
61. values for ID height and TARE between weighing If this option is disabled the user has to re enter these values for each reading If the values are not entered only the weight is stored NOTE These values cannot be retained by ID number 13 BALANCES COM OPERATION INSTRUCTIONS 02 Disp Height amp ID Yes AY to change Enter 01 14 2004 ZERO 11 30pm Oi b Height 6100 0 Oin ID 981723737123 11 30pm 53 4 lb When this option is activated the user will be asked to enter the patient s height after every weighing 01 14 2004 ZERO 03 Prompt For Height Yes AY to change Enter 04 Prompt For ID When this option is activated the user will be asked to enter the patient s ID number after every weighing Yes AY to change Enter 14 When the user selects to display the height and ID of the user it will be displayed at the bottom of the screen We recommend the use of this function to ensure that the patient s correct ID and height have been entered 01 14 2004 153i 11 30pm Please enter Height 0800 O Oin av to change Enter 01 14 2004 150321 Please enter ID 2345872336 11 30pm Enter AY to change BALANCES COM MAINTENANCE GENERAL This section provides instructions for maintenance cleaning troubleshooting and operator replaceable parts for the Pro Plus Electronic Handrail Scale Model 2101KL Maintenance operations other than th
62. weight on the scale platform The display will come to zero and TARE will be displayed to indicate there is a tare value in the memory as displayed in Figure 5 above Removing the Tare Additional pressing of the TARE button will delete the tare value from memory TARE will disappear from the display and the scale will resume normal operation 03 DATA MANAGEMENT The scale manages patient data including patient ID weight height tare and BMI The value is stored in memory or transferred to PC This function is performed by opening a new data file OPENING A NEW DATA FILE 1 Press the ID button 7 2 Using the keypad type in the identification number 3 Press ENTER BALANCES COM OPERATION INSTRUCTIONS This scale will also calculate Body Mass Index BMI CALCULATING BMI 1 Place the patient on the scale platform 2 Press the BMI button 2 3 The scale will prompt you to enter the patient s height Use the keypad to enter the height in 1 4 1 1 4 2 1 2 3 3 4 or 1 cm increments use inches for weight in Ib cm for kg Press ENTER 4 Display will read the patient s BMI The scale offers you two options to manage your information to transfer download the values or to store them The first option automatically downloads transfers the value to your PC The second option stores the value in memory The maximum capacity of the scale is 270 files of different data gt 02 Store In memory 03 Do not store da
Download Pdf Manuals
Related Search
Related Contents
Samsung RT-F250G TMF με Digital En détail, une circulaire de la Dreal Bretagne et du Cerema Technical specification - Xtender serial protocol Un jour à Lisieux : mode d`emploi. Hampton Bay BSG8116 Instructions / Assembly CoaXPress MC408x Camera Manual Ariens 029-034 Snow Blower User Manual Nortel Networks COMMISSIONING 8600 User's Manual Sony HT-DDW870 User's Manual Copyright © All rights reserved.